1 for DNE-K07 Reference and Installation Manual
2
3 TABLE OF CONTENTS INTRODUCTION...2 Specifications... 3 Navigation... 3 INSTALLATION...4 Viewing Angle... 4 Keypad Cover Clearance... 4 Mounting the Metal Wall Plate... 5 Connecting Grafica... 5 Mounting Grafica... 6 Unmounting Grafica... 8 PROGRAMMING...9 Entering Module Programming Mode... 9 Programming Methods SYSTEM OPTIONS...11 Partition Assignment Display Code Entry Display Exit Delay Display Entry Delay Confidential Mode Exit Delay Beep Keypad Tamper Beep on Trouble Confidential Mode Timer Download from the Memory Key Copy to Memory Key PROGRAMMING SECTIONS...18
4 1.0 INTRODUCTION Grafica is the most advanced keypad and communication device in the security industry. Developed to resolve operational flaws with security system keypads, Grafica offers the ability to view zone locations on a floor plan drawing through its graphic LCD screen and provides simple menu-driven commands that eliminate the need of user manuals thus reducing training time to a minimum. The software contains over 120,000 lines of code and was developed in collaboration with end users resulting in a keypad that is intuitive and guides the user to the next logical step. Other software-related features include downloadable tunes and bitmaps for many functions, a smart search engine for users and zones, alarm clock, and on-site upgradable firmware. Grafica s design uses the latest and most sophisticated technologies available, such as metallic colour finishing, laser-trimmed text, flexible and multi-layered PCBs and SMD fine-pitch components. With its shocking, ultra-modern style, Grafica sets a new milestone for communication devices in the security industry for years to come.
5 1.1 SPECIFICATIONS Power input: Typically 12 to 16 Vdc, 130mA maximum. Power indication: Blue LED on. Locate indication: Blue LED flashes. Bus fault indication: Fault indication message will appear on screen. Anti-tamper switch: Yes. Display: Film Super Twisted Nematic. (Black and white contrast). 128 X 128 pixels. Under ESD conditions the screen may go blank. To reset the screen press any key. Compatibility: DigiplexNE version 1.3 or higher. Winload version 2.2 or higher. NEware Version NAVIGATION Grafica s three action keys represent selections that appear directly above the key on the screen. They enable you to move forward/back, toggle the status of options and save choices. The scroll keys enable you to highlight and select options throughout the various menus. Action Keys Figure 1: Key Overview Scroll Keys DigiplexNE Grafica Keypad Module 3n
6 2.0 INSTALLATION 2.1 VIEWING ANGLE The Grafica keypad s graphic LCD is best viewed from a direct angle between a range of 20 and -10 (Figure 2). Be sure to install the Grafica keypad at a height and in a direction that provides the best viewing angle. Figure 2: Viewing Angle KEYPAD COVER CLEARANCE Grafica s keypad cover Figure 3: Cover Clearance requires sufficient space in order to open properly. Ensure a clearance of approx 3.5 (9cm) between the open keypad cover and possible obstructions such as a light switch (Figure 3). 3.5 (9cm) Light switch 4 Reference & Installation Manual
7 2.3 MOUNTING THE METAL WALL PLATE 1) Place metal wall plate to desired position. 2) Drill and insert screws into holes labeled A as shown in Figure 3. Figure 3: Metal Wall Plate A (Used also for electrical box) A A B B A C (for clip) A (Used also for electrical box) 2.4 CONNECTING GRAFICA You can connect Grafica to the DigiplexNE control panel s communication bus in a star and/or daisy chain configuration. The communication bus consists of four wires that provide power and two-way communication between the control panel and all modules connected to it. Connect the four terminals labelled RED, BLK, GRN and YEL of the module to the corresponding terminals on the control panel as shown in Figure 4 on page 6. Please refer to the DigiplexNE Installation & Reference Manual for maximum allowable installation distance from the control panel. DigiplexNE Grafica Keypad Module 5n
8 Figure 4: Connection Overview To other modules YEL GRN BLK RED Communication--- bus Grafica (partial view) To DigiplexNE control panel 2.5 MOUNTING GRAFICA 1) Place Grafica s back plate flush against the mounted metal wall plate. 2) Slide the Grafica s open slots labeled D (Figure 5 on page 7) onto the metal wall plate s tabs labeled B (Figure 6 on page 7). 3) Gently apply downward pressure to snap the Grafica onto the metal wall plate. 4) You may insert an optional screw under Grafica keypad through the space in the metal wall plate s left tab (Figure 6 on page 7). 6 Reference & Installation Manual
9 Figure 5: Grafica Back Plate D D Clip Figure 6: Mounting Grafica to Wall Plate B Metal wall plate Optional screw inserted here DigiplexNE Grafica Keypad Module 7n
10 2.6 UNMOUNTING GRAFICA 1) If required, remove the optional screw. 2) Gently lift the unit upwards with your hands until it separates from the metal wall plate (Figure 7). Figure 7: Unmounting the Grafica Metal wall plate 8 Reference & Installation Manual
11 3.0 PROGRAMMING Enter the Module Programming Mode, enter the desired section followed by the required data. When programming the Grafica, use the keypad s programming sheets (in the DigiplexNE Modules Programming Guide). Refer to Programming Sections in section 5.0 to keep track of which sections were programmed and how. We strongly recommend you read this entire manual before you begin programming. Grafica can also be programmed using the WinLoad Security System Management Software. For more information, refer to the WinLoad instructions or visit our Web site at Floor plans, tunes and graphics can be downloaded to Grafica using Winload V2.2 or higher and NEware V2.0 or higher. 3.1 ENTERING MODULE PROGRAMMING MODE Like all other keypads in the system, Grafica is programmed through the control panel. To do so, you must first enter the Module Programming Mode: Step 1: From Normal Mode press and hold the [0] key. Step 2: Enter the [INSTALLER CODE] (by default ). Step 3: Enter section [4003]. Step 4: Enter Grafica s 8-digit [SERIAL NUMBER]. Step 5: Enter the 3-digit [SECTION] you want to program. Step 6: Enter the required [DATA]. The control panel will then redirect all programming to the selected Grafica keypad. Use the scroll and action keys to navigate through desired sections. DigiplexNE Grafica Keypad Module 9n
12 The serial number is located on Grafica s PCB or enter section [0000] in Step 3 to view Grafica s version and serial number. 3.2 PROGRAMMING METHODS The following methods can be used when programming the Grafica keypad: FEATURE SELECT PROGRAMMING You can program sections by enabling or disabling options. Within these sections, keys [1] to [8] or scroll keys represent a specific Grafica option. Use the scroll keys to highlight the desired option and press the corresponding action key to enable or disable the option. An X will appear to indicate that the option is enabled. Press the appropriate action key to save the status of selected option(s) DECIMAL PROGRAMMING Some sections require the entry of a decimal value. For this method, any value from 000 to 255 can be entered HEXADECIMAL PROGRAMMING Some sections require the entry of a hexadecimal values [A] to [F]. Press the # key to scroll through these values. If the value is left unchanged for a second or two, Grafica will automatically select it, and move forward to the next digit. 10 Reference & Installation Manual
13 4.0 SYSTEM OPTIONS The following sections detail the options that can be programmed for Grafica. 4.1 PARTITION ASSIGNMENT SECTION [001]: OPTIONS [1] TO [8] Each keypad in the system can be assigned to one or more partitions. In section [001], options [1] to [8] represent partitions 1 through 8 respectively. To assign the keypad to a partition, enable the option that corresponds to the desired partition. By default, partitions 1 to 8 are enabled. 4.2 DISPLAY CODE ENTRY SECTION [002]: OPTION [1] This option displays the digits of the User Access Codes on the graphic LCD as they are entered. Option [1] OFF = Digits are replaced by a *. (Default). Option [1] ON = Access Code digits will be displayed. 4.3 DISPLAY EXIT DELAY SECTION [002]: OPTION [2] Based on the user's needs, an Exit Delay Timer can be programmed to provide the user time to exit the partition before the system is armed. If this option is enabled, the Exit Delay Timer's countdown will appear on the graphic LCD screen next to the hour-glass icon. Option [2] OFF = Exit delay time will not appear. Option [2] ON = Exit delay time will appear (Default). DigiplexNE Grafica Keypad Module 11n
14 4.4 DISPLAY ENTRY DELAY SECTION [002]: OPTION [3] Based on the user's needs, an Entry Delay Timer can be programmed to provide the user time to enter their User Access Code before the alarm is triggered. If this option is enabled, the Entry Delay Timer's countdown will appear on the graphic LCD screen next to the hourglass icon. Option [3] OFF = Does not display Entry Delay Timer. Option [3] ON = Displays Entry Delay Timer (Default). 4.5 CONFIDENTIAL MODE SECTION [002]: OPTIONS [4] AND [5] This option is not for UL Installations. If the Confidential Mode is enabled and no actions are performed on the Grafica keypad for a period of time, the graphic LCD will display the time, date and all LEDs on the keypad will turn off until either a key is pressed, or an access code is entered. The period of time in which no action is performed is defined by the Confidential Mode Timer on page Reference & Installation Manual
15 Grafica will go from Confidential Mode into Normal Mode once a key is pressed or a code is entered. In normal mode, Grafica displays the date, time, as well as the status of open zones for every partition that the keypad is assigned. In addition, Alarm Memory Display, Bypassed zones and the Trouble Display can be displayed. SECTION [002]: OPTION [4] Option [4] OFF = Normal Mode (Default). Option [4] ON = Confidential Mode. SECTION [002]: OPTION [5] Option [5] OFF = Exit confidential mode by entering an access code (Default). Option [5] ON = Exit confidential mode by pressing a key. The default option in Section [002] Option 5 (default) will only work if option [4] in section [002] is enabled. 4.6 EXIT DELAY BEEP SECTION [002]: OPTION [6] The keypad can beep once every second or play a selected song during the Exit Delay Timer. During the final 10 seconds only the beep tone will be heard (at a faster interval) to provide a final warning before the area is armed. Option [6] OFF = Exit Delay beep disabled. Option [6] ON = Exit Delay beep enabled (default). 4.7 KEYPAD TAMPER SECTION [002]: OPTION [8] When tamper is enabled and the keypad's anti-tamper switch is triggered, the keypad will send a Tamper report to the control panel DigiplexNE Grafica Keypad Module 13n
16 via the communication bus. Option [8] OFF = Grafica s anti-tamper switch is disabled. (Default) Option [8] ON =Grafica s tamper is enabled. 4.8 BEEP ON TROUBLE SECTION [003]: OPTIONS [1] TO [4] Potential troubles have been sorted into groups. With these options enabled, the keypad will emit an intermittent beep tone whenever a trouble condition occurs from one of the Trouble Groups. The intermittent beep will remain activated until the user enters the Trouble Display or if the trouble is resolved. For a list of troubles, see the DigiplexNE Reference and Installation Manual. The intermittent beep will be re-initialized whenever the trouble condition reoccurs. By default, options [1] to [4] are OFF SYSTEM AND CLOCK TROUBLE BEEP SECTION [003]: OPTION [1] Option [1] OFF = Beep disabled (Default). Option [1] ON = Beep on: System Troubles and Clock Loss COMMUNICATOR TROUBLE BEEP SECTION [003]: OPTION [2] Option [2] OFF = Beep disabled (Default). Option [2] ON = Beep on: Communicator Troubles. 14 Reference & Installation Manual
17 4.8.3 MODULE AND BUS TROUBLE BEEP SECTION [003]: OPTION [3] Option [3] OFF = Beep disabled (Default). Option [3] ON = Beep on: Module and Bus Troubles ALL ZONE TROUBLE BEEP SECTION [003]: OPTION [4] Option [4] OFF = Beep disabled (Default). Option [4] ON = Beep on: all Zone Troubles. 4.9 CONFIDENTIAL MODE TIMER SECTION [004] Section [004] determines the amount of time without action before the keypad enters Confidential Mode, (see page 12). The Confidential Mode Timer can be set from 005 seconds to 255 seconds. Default: 120 seconds DOWNLOAD FROM THE MEMORY KEY SECTION [100] Use this section to download Grafica s section [001] to [004], all zone labels, area labels, and user labels from the Memory Key. To download the contents: 1) Insert the Memory Key onto the keypad s connector (see Figure 8 on page 16). 2) To download the contents of the Memory Key, enter the keypad s programming mode and enter section [100]. 3) When the keypad emits a confirmation beep, wait five seconds and remove the Memory Key after the second confirmation beep. DigiplexNE Grafica Keypad Module 15n
18 Figure 8: Memory Key Connector (partial view) 4.11 COPY TO MEMORY KEY SECTION [110] Use this section to copy Grafica sections [001] to [004], all zone labels, area labels, and user labels to the Memory Key. To copy the contents: 1) Insert the Memory Key onto the keypad s connector. Ensure the write protect jumper is on (figure 9 on page 17). 2) To copy the contents to the Memory Key, enter the keypad s programming mode and enter section [110]. 3) After the confirmation beep, wait five seconds and remove the Memory Key after the second confirmation beep. Remove the Memory Key s jumper if you do not wish to accidently overwrite its contents. 16 Reference & Installation Manual
19 Figure 9: PMC-3 Jumper Settings Only the PMC-3 Memory Key will function with Grafica keypads. DigiplexNE Grafica Keypad Module 17n
20 5.0 PROGRAMMING SECTIONS = Default Setting Section [001]: Keypad Partition Assignment Option OFF ON [1] PARTITION 1 DISABLED ENABLED [2] PARTITION 2 DISABLED ENABLED [3] PARTITION 3 DISABLED ENABLED [4] PARTITION 4 DISABLED ENABLED [5] PARTITION 5 DISABLED ENABLED [6] PARTITION 6 DISABLED ENABLED [7] PARTITION 7 DISABLED ENABLED [8] PARTITION 8 DISABLED ENABLED = Default Setting Section [002]: General Options 1 Option OFF ON [1] DISPLAY CODE ENTRY DISABLED ENABLED [2] DISPLAY EXIT DELAY DISABLED ENABLED [3] DISPLAY ENTRY DELAY DISABLED ENABLED [4] CONFIDENTIAL MODE DISABLED ENABLED [5] TO EXIT CONFIDENTIAL MODE * ENTER CODE PRESS KEY [6] EXIT DELAY BEEP DISABLED ENABLED [7] FUTURE USE N/A N/A [8] KEYPAD TAMPER DISABLED ENABLED * Must be enabled through Option [4] in section [002] first. 18 Reference & Installation Manual
21 = Default Setting Section [003]: Beep on Trouble Option OFF ON [1] SYSTEM & CLOCK TROUBLE BEEP DISABLED ENABLED [2] COMMUNICATOR TROUBLE BEEP DISABLED ENABLED [3] MODULE & BUS TROUBLE BEEP DISABLED ENABLED [4] ALL ZONE TROUBLE BEEP DISABLED ENABLED [5] FUTURE USE N/A N/A [6] FUTURE USE N/A N/A [7] FUTURE USE N/A N/A [8] FUTURE USE N/A N/A 120 seconds Default Setting Section [004]: Confidential Mode Timer Data / / (005 to 255 seconds) Section [100]: Download From Memory Key DOWNLOAD DATA FROM MEMORY KEY Section [110]: Copy to Memory Key DOWNLOAD DATA TO MEMORY KEY DigiplexNE Grafica Keypad Module 19n
22 Warranty The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits, stolen goods, or claims by any other party caused by defective goods or otherwise arising from the improper, incorrect, or otherwise faulty installation or use of the merchandise sold Paradox Security Systems Ltd. Grafica, DigiplexNE, Winload and NEware are trademarks of Paradox Security Systems. 20 Reference & Installation Manual
23
24 Printed in Canada - 08/2002 GRAFICA-EI01
616, 626, 636 & 646 Keypads
616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15
PK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
642 LCD Keypad User Manual
642 LCD Keypad User Manual TABLE OF CONTENTS Introduction...3 Legend... 3 Basic Operation...5 Keypad Indicator Lights... 5 Visual Feedback... 5 Auditory Feedback... 6 Info List... 7 Access Codes...8 User
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
VARIO PROX CARD READER INSTALLATION MANUAL
VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8
LCD5500Z / PKP-LCD v3.x Installation Instructions
LCD5500Z / PKP-LCD v3.x Installation Instructions TM Introduction The LCD5500Z / PKP-LCD keypad displays system status using an LCD screen. The keypad can be used on PowerSeries security systems with up
LCD and 16-Zone LED Keypads. User s Manual
LCD and 16-Zone LED Keypads 1689 1641 16-Zone LED Keypad LCD Keypad User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION...3 2.0 BASIC OPERATION...4 2.1 Keypad Indicator Lights... 4 2.2 Visual Feedback...
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
PC Tab Security System INSTRUCTION MANUAL
PC Tab Security System INSTRUCTION MANUAL This manual is intended as a Quick Start manual covering the basic functions that have been enabled on the alarm panel. The alarm panel is capable of extensive
10-Zone Spectra LED Keypads
10-Zone Spectra LED Keypads 1686V 1686H User s Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your
A) Power light: On = AC power Off = Power failure Flash = System is locating the keypad A 6
K07C: Grafica Color Keypad Quick Start Description Grafica sets a new milestone for keypads in the security industry. Grafica features a full color LCD screen and offers the ability to view zone locations
PowerWave-8. Users Operating and Programming Guide Version 8.64. 8 zone Control panel Communicator
ELECTRONIC ENGINEERING LTD. PowerWave-8 8 zone Control panel Communicator Users Operating and Programming Guide Version 8.64 P/N 7101261 Rev. C N.A July 2002 2 Contents Introduction...5 Meet the Crow Alarm
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
Digiplex LCD Keypad DGP-641. User s Manual
Digiplex LCD Keypad DGP-641 User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION... 7 1.1 Legend... 7 2.0 BASIC OPERATION... 8 2.1 Auditory Feedback (Beep Tones)... 9 2.2 Keypad Indicator Lights... 9 2.3
Spectra SP Expandable Security Systems
Spectra SP Expandable Security Systems Control Panels Feature Comparison between Spectra SP Control Panels Feature SP4000 SP65 SP5500 SP6000 SP7000 StayD Maximum Zones 32 32* 32* 32* 32* On-board Zones
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
Table Of Contents. System Monitoring... 14 System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...
Quick Start Table Of Contents Getting Started... 2 NEware Editions...2 Installing NEware...3 Installing Languages...3 Connecting to NEware...3 Changing Your IP100 Password...4 User Codes... 5 Master Feature...5
GSM Communicator Module PCS100 V1.1
GSM Communicator Module PCS100 V1.1 Installation and User Manual Warranty Paradox Security Systems Ltd. ( Seller ) warrants its products to be free from defects in materials and workmanship under normal
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone
Owner s Guide. ca6554
PROFESSIONAL SERIES Owner s Guide For Models: ca6554 Deluxe Vehicle Security and Remote Start System with 2 Way Confirming LCD Remote Control IMPORTANT NOTE: The operation of the Security and Convenience
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
Crow Limited Warranty. Print Version 017
Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Wireless Home Security System Product Manual (Model #80355)
Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.
NortechCommander Software Operating Manual MAN-00004 R6
NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned
EKP1 LED KEYPAD. Owner's Manual. Use with AV9000 & SC800/1600 Series Control panel
EKP1 LED KEYPAD Owner's Manual Use with AV9000 & SC800/1600 Series Control panel IT IS IMPORTANT FOR YOUR SAFETY TO TEST YOUR SYSTEM AND IT'S COMPONENTS REGULARLY. P/N 64812816 A PDF 10/24/97 Table of
1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function
WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
CA-125 Owner's Manual
Remote Vehicle Control System CA-125 Owner's Manual Vehicle Security System With Remote Keyless Entry IMPORTANT NOTE: The operation of the Security and Convenience System as described in this manual is
AD-01 Slave Auto Dialer. Owner s Manual
AD-01 Slave Auto Dialer Owner s Manual AD-01 Slave Manual.indd 1 10/15/2009 10:20:44 AM 2 AD-01 Slave Manual.indd 2 10/15/2009 10:20:44 AM Features: Programmable entry/exit delay time; select up to 9 (32
INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD
INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD TABLE OF CONTENTS SYSTEM INFORMATION 2 INTRODUCTION 3 Test Your System Regularly...3 Important Notice...3 Glossary...3 BASIC OPERATION 4 Arming Your System...4
2-Way Wireless Indoor Siren Installation Guide
2-Way Wireless Indoor Siren Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
CS848E Receiver for 868GEN2 Devices Installation Sheet
CS848E Receiver for 868GEN2 Devices Installation Sheet EN 1 2 1 3 4 2 3 EN: Installation Sheet Description The CS848E Receiver adds wireless capabilities to the CS line of control panels. The CS848E allows
GSM Autodialer Professional GJD700 Speech & Text Autodialer
Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred
Digiplex Control Panel (DGP-848) - V4.1
Digiplex Control Panel (DGP-848) - V4.1 DGP-848 Reference and Installation Manual Includes DGP2-641BL/RB Installation Instructions Table of Contents Introduction... 1 Features... 1 Specifications... 1
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
Automatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are
Trilogy DL2700 Programming Instructions OI209A 2/04
345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 ALARM LOCK 2004 Trilogy DL2700 Programming Instructions OI209A 2/04 CONGRATULATIONS!
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide "sona control unit install" For use with Wi-Safe 2 Smoke, Heat and Carbon Monoxide Alarms 1 PLEASE READ THIS GUIDE IN FULL BEFORE
MG5000 V2.40 MG5050 V2.40 SP5500 V2.40 SP6000 V2.40 SP7000 V2.40. Reference & Installation
MG5000 V2.40 MG5050 V2.40 SP5500 V2.40 SP6000 V2.40 SP7000 V2.40 Reference & Installation We hope this product performs to your complete satisfaction. Should you have any questions or comments, please
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-5587722 +972-3-5500442 [email protected] http://www.pima-alarms.com
CAD-05 Kit GSM Auto Dialer. Owner s Manual
CAD-05 Kit GSM Auto Dialer Owner s Manual CAD-05 Kit Manual.indd 1 Warnings: This device complies with Part 15 of the FCC rules, Operation of this device is subject to the following conditions: 1. This
System Manager s Manual for DGP-848 Systems
LCD Keypad Module DGP2-641/DGP2-641R DGP2-641BL/DGP2-641RB System Manager s Manual for DGP-848 Systems Also includes Operating Instructions Table of Contents Introduction... 1 Legend... 1 Basic Operation...
Solution-16 Operators Manual ISSUE 1.60
Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Important Notice This guide is delivered subject to the following conditions and restrictions:
User Manual Important Notice This guide is delivered subject to the following conditions and restrictions: Agility User Manual This guide contains proprietary information belonging to RISCO Group. Such
CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com
CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i
PRT-CTRL-SE. Protege System Controller Reference Manual
PRT-CTRL-SE Protege System Controller Reference Manual The specifications and descriptions of products and services contained in this document were correct at the time of printing. Integrated Control Technology
Auto Dialer. Manual E-921APQ E-921GPQ
Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have
15 Digital Photo Frame Instructional Manual
15 Digital Photo Frame Instructional Manual aluratek.com mnl M10054 ADMPF315F Copyright 2011 Aluratek, Inc. All Rights Reserved. Table of Contents Frame Close-up... Remote Control Close-up... Package Contents...
VR8. User Guide Intruder Alarm System
VR8 EN User Guide Intruder Alarm System VR8 User Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights
9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
Digiplex LCD Keypad DGP-641. User s Manual
Digiplex LCD Keypad DGP-641 User s Manual 1.0 TABLE OF CONTENTS INTRODUCTION...6 1.1 Legend... 6 BASIC OPERATION... 7 2.1 Auditory Feedback (Beep Tones)... 8 2.2 Keypad Indicator Lights... 8 2.3 LCD Screen...
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
ELECTRONIC ENGINEERING LTD. PowerWave-16. 16 zone Control panel Communicator. User s Operating and Programming Guide. Version: 6.
ELECTRONIC ENGINEERING LTD. PowerWave-16 16 zone Control panel Communicator User s Operating and Programming Guide Version: 6.28 P/N 7121240 Rev c N.A May 2003 Contents Introduction... 4 Meet the Crow
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
User s Manual. Bluetooth Calculator Keypad. Page
User s Manual Bluetooth Calculator Keypad Page Regulatory Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
System Manager s Manual
LCD Keypad DGP2-641B / DGP2-641RB DGP2-641 / DGP2-641R System Manager s Manual Also includes Operating Instructions Table of Contents Introduction... 1 Legend... 1 Basic Operation... 1 Auditory Feedback
PixController, Inc. Wireless Digital PIR Sensor
PixController, Inc. Wireless Digital PIR Sensor Model: SEN-400 User s Manual Version 1.00 WARRANTY REGISTRATION PixController, Inc. warrants products sold by it and guarantees to correct, by repair or
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1
ITC-BTTN Cellular Bluetooth Gateway Owner s Manual 1 2 Table of Contents Introduction...3 Package Contents...3 XLink Connections Diagram...4 Setup...5 Pairing your Bluetooth Cell Phone to the XLink...6
SCORPION Z16040C Alarm Controller User Instructions
SCORPION Z16040C Alarm Controller User Instructions Thank you for choosing to purchase this micron security alarm controller. Micron product is manufactured to exacting quality standards. We understand
FXM Communication Manual
Operator s Manual 017-201-B1 9/06 EFFECTIVE: September, 2006 Alpha Technologies Power Alpha Technologies 1 Introduction to FXM Computer Communication There are several ways to connect a computer to the
SPECIAL CONTROL BUTTON FUNCTIONS
Operating Guide 1 2 3 CONTENTS Page No. OPERATING YOUR ALARM 5 General Information 5 Arming the Alarm 5 Disarming the Alarm 6 Arming in Stay Mode 7 Disarming Stay Mode 8 Bypassing Zones 8 Manual Panic,
Application Notes. 1.21 Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4.
Application Notes 1.21 Partition Programming (PC1616/1832/1864 V4.2) Panels: POWER SERIES (PC1616/1832/1864 V4.2) Overview: The PC1616 supports 2 true partitions. The PC1832 supports 4 true partitions.
1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE Software Version 2.1
1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE Software Version 2.1 DEFAULT INSTALLER CODE 000000 (see section [281] on page 18) DEFAULT SYSTEM MASTER CODE 123456 (see section [301] on page 18)
ELECTRONIC ENGINEERING LTD. Runner Series WIRELESS AND WIRED CONTROL PANEL. User s Guide. Version 9.08.2
ELECTRONIC ENGINEERING LTD. Runner Series WIRELESS AND WIRED CONTROL PANEL User s Guide Version 9.08.2 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship
Spectra T50e Flash (SD) Card Installation Instructions
Spectra T50e Flash (SD) Card Installation Instructions PN 90970021 Revision A Notices Notices Except as expressly stated herein, Spectra Logic Corporation makes available this Spectra library and associated
LST-3800. In-Dash Digital Sonar Gauge. Installation & Operation Instructions
Pub. 988-0064-351 LST-3800 In-Dash Digital Sonar Gauge Installation & Operation Instructions The LST-3800 is a depth and temperature gauge that comes with a 200 khz transducer, features deep and shallow
VOICE DIALER MODULE V1.10
VOICE DIALER MODULE V1.10 SECURITY HAS A VOICE REFERENCE AND INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION... 3 1.1 SYSTEM FEATURES... 3 1.2 TECHNICAL SPECIFICATIONS... 4 1.3 GLOSSARY OF TERMS...
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
Control panel software versions 2.00 and beyond.
ESPRIT BURGLAR ALARM CONTROL PANEL Welcome to the world of ESPRIT technology. Your Esprit control panel has been designed with ease of use and simplicity in mind. We ve developed a highly advanced technology
AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions
AIM TECHNICAL MANUAL AIM-1450HW HARDWIRE PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING See page 9 for Activation Instructions AIM Technical Manual - AIM 1450HW AIM-1450HW HARDWIRE ABOUT
How To Control Networx From A Cell Phone Or Ipad (For A Cell) On A Networe) On An Ipad Or Ipa (For An Ipa) On Your Ipa Or Ipam (For For A
NX-592E-GSM Wireless Gateway Installation Manual g Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2008 GE Security. All rights reserved. This document may not be copied
NetworX Series. NX-216E Zone Expander Module Installation and Startup
NetworX Series NX-E Zone Expander Module Installation and Startup 00 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every
CA 1050 Owner s Guide
PROFESSIONAL SERIES CA 1050 Owner s Guide Vehicle Security and Keyless Entry System IMPORTANT NOTE: The operation of the Security and Convenience System as described in this manual is applicable to most
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
Contents 1. Terms you may neeed to know 2. Keypad Lights 3, 4. Keypad Buttons 5
Security Alarm System Owner's Guide 8 sector CDS Dialler Version 2.0 lcopm.pm6 Contents Contents 1 Terms you may neeed to know 2 Keypad Lights 3, 4 Keypad Buttons 5 User Functions Fully Arming the System
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
Trilogy Series DL3000 Programming Instructions
ALARM LOCK Trilogy Series DL000 Programming Instructions PLUG IN THEN ENTER YOUR CODE ALARM LOCK DL000 Trilogy Series Standalone Access Control System ALARM LOCK OI224C 8/98 1 Features -----------------------------------------------------------------------------------------------------4
All-In-One Wireless Console (MG6130 / MG6160) User Guide
All-In-One Wireless Console (MG6130 / MG6160) MG6130 User Guide MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
Mounting and operating instructions. Surface-mounted hands-free feature home station 1250..
Mounting and operating instructions Surface-mounted hands-free feature home station 1250.. Device description The surface-mounted hands-free feature home station is a prefabricated unit and is part of
MTX-D, Oil Temperature/Pressure Gauge
MTX-D, Oil Temperature/Pressure Gauge 1 Mounting and Sensor Installation... 3 1.1 Mounting the Gauge... 3 1.2 Oil Temp Sensor... 3 1.3 Oil Pressure Sensor... 3 2 Wiring... 3 2.1 Main Gauge Wiring... 4
AUTODIALLER / QUICKDIALLER - SA132
AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING
VIBRATION WATCH with: Vibration Alarm (won't disturb others). Beep Alarm (optional) Electro-Luminescent (EL) back light (for viewing display at
VIBRATION WATCH with: Vibration Alarm (won't disturb others). Beep Alarm (optional) Electro-Luminescent (EL) back light (for viewing display at night). Second Clock (great when traveling in a different
INSTRUCTION MANUAL LCD-6OO SECURITY STATION
INSTRUCTION MANUAL 1993 Digital Security Controls Ltd. 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6 Printed in Canada 29000144 R1 LCD-6OO SECURITY STATION Table of Contents Introduction 1 About
IMPORTANT See last page for changes from VERSION 1.2. To enter programming, press [ENTER] + installer code (Installer default code 747474)
SOFTWARE VERSION 1.3 IMPTANT See last page for changes from VERSION 1.2 To enter programming, press [ENTER] + installer code (Installer default code 747474) ADDRESSES: addresses "000" to "255" ( key [10]
SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals
SSW-iLM Keypad Note: This product is designed to be installed and serviced by security and lock industry professionals Specifications Case dimensions: 6 1/2 L x 1 3/4 W x 1 1/8 D Electrical: 5-12VDC Only
Ultrasonic Distance Meter. Operation Manual
XPROTEC Ultrasonic Distance Meter Operation Manual About XProTec Pro-Installer Tools The XProTec line from XFTP is a comprehensive lineup of professionalgrade technical tools. These full-featured, field-proven,
Reference & Installation Manual
& Versions 4.4 (728ULT) & 4.1 (738ULT) 728ULT 738ULT Reference & Installation Manual Table of Contents Introduction... 1 About This Manual... 1 New Features... 1 Main Features... 1 Specifications... 1
Solution 16 plus. User Guide Security System
Solution 16 plus EN Security System Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights are reserved.you may download
2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal
O N DS160/DS161 Installation Guide High Performance Request-to-Exit Sensors 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for Request to Exit (REX) interior applications.
ST815 Illumination Sensor with LCD
ST815 Illumination Sensor with LCD The Illumination Sensor with LCD (refer to as Illumination Sensor hereafter) is a Z-Wave TM enabled device which is fully compatible with any Z-Wave TM enabled network.