Build in self resetting protection systems: short circuit, overwattage overvoltage, thermal.



Similar documents
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

15 Series - Electronic step relay and dimmer. Features SERIE

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

SX460. Generator Automatic Voltage Regulator Operation Manual

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

People s Physics Book

KIT DOWNLIGHT HALOSPOT 111 ES

1. Scope This specification is applied to ICR Product Specification Table 1 No. Item Rated Performance Remark

HERZ-Thermal Actuators

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

M-Bus Network Installation Notes

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

Ohm's Law and Circuits

Inductive Proximity Sensors

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

TROUBLESHOOTING LED DOWNLIGHTS

USER MANUAL PLEASE KEEP THIS FOR FUTURE USE

How To Use An Akua Magnetic Lime Scale Preventing Device

13 SERIES. Electronic step relays A

FT-100 Fire Training Fog Machine User Manual English

Features. High Brightness LED Light source

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Adding Heart to Your Technology

Photovoltaic Cell: Converting Light to Electricity

VCE VET ENGINEERING STUDIES

K E E P E TH T I H S I MA M N A U N A U L A FO F R

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Video Camera Installation Guide

Operating Instructions. Room temperature controller

Li-ion Polymer Battery Specification

Product Information LED PARATHOM PAR Product Overview. Benefits. Key Features

SAMSUNG ELECTRONICS LED

IVIOS LED III. LUM Technical Information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

MOUNTING AND OPERATING INSTRUCTIONS

Monitors. Platea Monitor

Linear actuator Econom 0. Our intelligent model: Econom 0. Econom 0

ECOPTIMO T8. Version IRIS 2002,S.A. C/San Agustin, Madrid SPAIN T F

Copper wire figures. AWG Table

e d u c a t i o n NXT Solar Station

Delightful light.

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

ACS-30-EU-EMDR-10-MOD

Product Safety Notice Evolution Floodlight

Circuit symbol. Each of the cells has a potential difference of 1.5 volts. Figure 1. Use the correct answer from the box to complete the sentence.

K-Type Thermocouple Sensor User s Guide

E-WERK Bike-mobile hub dynamo powered supply unit for electronic devices. Instruction manual. Please study carefully before using E-WERK!

12V Dimmable Driver EL-TMDRVR

BX7000 Multi-Access Gateway Getting Started Guide

Via dell' Industria, S. Vendemiano (TV) Tel Fax Acquisti@elettrolab.

Product Information. LED SUPERSTAR MR Adv. Product Overview. Benefits. Key Features

Charge Regulator SCR 12 Marine

Safety automation solutions

Do not touch glass part of the bulb with your hands during installation.

Photovoltaic Solar Energy Unit EESFB

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

Documentation. M-Bus 130-mbx

LOW-VOLTAGE CURRENT TRANSFORMERS

LED LIGHTING CATALOG 2014 vol.1. Dimmer Power Supplies

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

unit : mm With heat sink (see Pd Ta characteristics)


Adapted from The NEED Project, Manassas, VA. Lesson 10 Overhead 1 of 8

PART 1 PRODUCT (GENERAL)...1.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Dimmer and Bulb Compatibility

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

UT202A Operating Manual. Contents

An Electrical Lab Exercise on Voltage Drop

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Fundamentals of Power

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

Three-phase monitoring relay CM-PFE

Operating instructions

DMX512 TO 0-10 VOLT ANALOG CONVERTER OWNERS MANUAL

DCP Fan Controller. Version 01/2009. The engineer s choice

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

T8 1200mm LED Tube 18 W FICHA TÉCNICA (1/5)

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Single Channel Loop Detector

Three Channel Optical Incremental Encoder Modules Technical Data

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Transcription:

Our Electronic Transformers are designed to use with low voltage halogen lamps. Precisly set, soft power supply make lamps live two times longer. Construction of our transformers remove main flaws of traditional ones such as output voltage scatter and power stroke at startup. Besides powering lamps they have additional functions which make this product interesting among direct market competitors. Transformers have folowing functions: Works with light dimmers. Build in self resetting protection systems: short circuit, overwattage overvoltage, thermal. Work from "0" to nominal wattage. Output Voltage lowered to 11,5V in order to extend lamp life. Posibility of instalation on surface of indeterminate flammable class. Fast instalation with attached screws. 1

ELECTRONIC TRANSFORMER Electronic Transformer 1V 50W Power factor Input terminals Output terminals EAN code Symbol: T-0506-0E 0, A 0-50 W 0.99 75g.5906160700000 Electronic Transformer 1V 60W Power factor Input terminals Output terminals EAN code Symbol: T-0606-0E 0,7 A 0-60 W 0.99 75g.5906160700086

Electronic Transformer 1V 70W Symbol: T-0706-0E 0,35 A 0-70 W Input terminals Output terminals 115g EAN code.5906160700017 Electronic Transformer 1V 105W Symbol: T-1051-0E 0,45 A 0-105 W Input terminals Output terminals 4 10g EAN code.590616070004 3

Electronic Transformer 1V 150W Symbol: T-1501-0E 0,65 A 0-150 W 35g EAN code.5906160700031 Electronic Transformer 1V 10W Symbol: T-101-0E 0,93 A 0-10 W 85g EAN code.5906160700093 4

Electronic Transformer 1V 50W Symbol: T-501-0E 1,1 A 0-50 W 85g EAN code.5906160700048 Electronic Transformer 4V 70W Symbol: T-070-0E 0,35 A 0-70 W 4 V Input terminals Output terminals 115g EAN code.0000000000000 5

Electronic Transformer 4V 150W Symbol: T-150-0E 0,65 A 0-150 W 4 V 35g EAN code.5906160700154 6

Instalation hints: Instal in places with good air flow, away from heat sources. Don't conect transformers outputs. When output wires have diameter higher then 4 mm, there should be used connection bar to connect lamps. Minimal lenght of output wires - 30cm Lenght of output wires leading to each light point should be equal. To avoid difrences in brightness level. When distance between transformer and halogen lamps is big use conection as shown below, don't use series connection. Biger number of halogen lamps, conect as shown on diagram below. Pay attention to corectly conect halogens when larger number used. Output wires should be in one isolation, in case of single wires, they should be twisted around eachother. Light dimmer should be instaled on power input wire leading to transformer. should be measured with TRUE RMS 100 khz voltage meter, use of other type of voltage meter my show wrong result. Load on pair of output terminals cannot exceed 85W. Load should be divided equally on all output terminals. 7