1 K-Type Thermocouple Sensor User s Guide 1
2 TABLE OF CONTENTS: 1 INTRODUCTION TYPICAL APPLICATION: INSTALLATION RULES: Connecting the sensor to M1/MD4 data logger: Connecting the sensor to MD3 data logger: IDENTIFYING THE SENSOR IN GET DATA LOGGER SETUP OUTPUT VOLTAGE CHARACTERISTS TECHNICAL FEATURES INTRODUCTION The GET K-Type Thermocouple temperature sensor it s designed to measure temperatures between 300 C and 1000 C. It is characterized to a quick response at every temperature variation. The total loom length is about 1 m. 2 TYPICAL APPLICATION: Usually the K-Type thermocouple sensor is used to monitoring the exhaust gas temperature of 2 and 4 stroke engine. Please make sure that you are using the sensor in his correct working range: an incorrect application may be causes damages or wrong measurements. 3 INSTALLATION RULES: For best performance and reliability, please follow the these rules: Don t place the sensor less than 40 cm from exhaust stirrup No tension in the sensor wire 3.1 Connecting the sensor to M1/MD4 data logger: The GET K-Type Thermocouple sensor must be powered at +12 V. An electronic regulator circuit provides to obtain the output signal between 0 and 5 V. The Thermocouple sensors can be connected at GET data loggers a Binder connector. 3 pole Binder pinout (wire output side): Pin Wire Color Description 1 Red +12 V power supply 2 White (or Green) Segnale 3 Black Ground 2
3 3.2 Connecting the sensor to MD3 data logger: Connect the sensor to one of the analog inputs on the MD3 Series logger using the adapter as shown below: Connect here WARNING: CONNECT THE ADAPTER FOLLOWING THE NAMES ABOVE THE CONNECTORS (SEE PICTURE). The analog input can be selected among the AD1, AD2, AD3 or AD4 (in the picture we used AD1), same thing for IC1 and IC2. DO NOT CONNECT AN AD INPUT TO THE IC INPUT OF THE MD3! Once the adapter is connected, the IN IC connector is ready for any digital signal (for instance RPM or speed) coming from the MD3 Series logger. If you have an MD3 PRO logger, connect the signal to any 5V or 12V analog input following the signal order as describe in chapter 3.1 above. 3
4 4 IDENTIFYING THE SENSOR IN GET DATA LOGGER SETUP Connect the sensor to one of the analog inputs of GET data logger using the correct connectors. The Thermocouple temperature sensor are suitable for any other data logger because they generate a tension depending the temperature. After connection at the analog input (AD1, AD2, etc..) the user needs to configure the sensor using Setup Manager software, under the Analog Channels tree. Please follow these steps: Click and run the Setup Manager from the GATE window as shown below. Download the setup from the device to your computer clicking on the download icon on the menu bar or clicking on Open from Device in the Setup menu. Download Setup from Device icon Once downloaded, the setup is displayed in Setup Manager. For instance if you have connected the sensor signal to the AD1 analog input; click on AD1 in the Analog Channels tree: channel properties are shown on the right. Decimal places: enter the number of decimal places to be displayed in the channel values Logging rate: enter the channel acquisition frequency. User can choose between None (no acquisition), 1Hz, 5Hz, 10Hz, 50Hz, 100Hz, 500Hz Name: channel name, in our case, for example, TEM Unit: enter the unit of measurement of the channel value ( C in our case ) 4
5 It is now necessary to calibrate the channel (this operation is necessary to obtain the correct value of the signal being acquired). Click on Calibrate Channel in the bottom right-hand corner: the calibration window of the channel selected previously will appear: Once you have entered the calibration window, it is necessary to define: Calibration Type: defines the type of channel calibration (in this particular case, set Thermocouple) Send the Setup to the device: click on Send Setup to Device in the Setup menu. Send Setup to Device icon 5
6 5 OUTPUT VOLTAGE CHARACTERISTS The graphic below show the Voltage vs. Temperature characteristics of the K-Type Thermocouple sensor. The table below show the output voltage vs. temperature: this data can be useful to connect the temperature sensor to any data logger. Temperature ( C) Voltage (V)
7 6 TECHNICAL FEATURES Temperature Measurement Range ( C) Resolution Case Material Acciaio Inox per alte temperature Wrench (mm) 13 Body thread (MA) M8x1.25 Threading length (mm) 10 Sensitive part diameter (mm) 1.5 Sensitive part length (mm) 12 Electric cable length (mm) 100 Conductors section (AWG) 24 Electrical cable coating PTFE 7
8 8
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Quick Start Using DASYLab with your Measurement Computing USB device
Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC). This Quick Start document contains
Trigno/Vicon System Integration
Delsys and Vicon Analog Integration Motion capture systems will often have the ability to sample analog data channels as a convenient means for synchronizing external data streams with motion capture data.
Article : A-451. RPM amplifyer. Technical card : 20-08-2007 Updated : 21-05-2008
Technical card : 20-08-2007 Updated : 21-05-2008 Article : A-451 RPM amplifyer Application : It is an electronic amp with microprocessor which adapts the RPM signals coming from nearly all types of engines
SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.
How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers. OMEGALOG Help Page 2 Connecting Your Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data Page 11 Downloading
Copyrights 2010 Victron Energy B.V. All Rights Reserved
Manual EN 1 Copyrights 2010 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose. For conditions of use and permission
RHINO TRACKS STANDARD GPS VEHICLE TRACKER
RHINO TRACKS STANDARD GPS VEHICLE TRACKER Product Code: RHINO TRACKS STS ABOUT YOUR RHINO TRACKS STS This user guide covers the installation and operation of your RHINO TRACKS STS. The latest version of
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
MXL2 Dash Logger USER GUIDE
Dash Logger USER GUIDE AiM Srl. Via Cavalcanti, 8 20063 Cernusco S/N (MI) Italia Tel. (+39) 02.9290571 Made in Italy www.aim-sportline.com Dash Logger 04 06 08 10 11 12 12 12 14 14 14 14 16 17 18 19 21
QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 956 24-BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION
LTC2485 DESCRIPTION Demonstration circuit 956 features the LTC2485, a 24-Bit high performance Σ analog-to-digital converter (ADC). The LTC2485 features 2ppm linearity, 0.5µV offset, and 600nV RMS noise.
Appendix C. Vernier Tutorial
C-1. Vernier Tutorial Introduction: In this lab course, you will collect, analyze and interpret data. The purpose of this tutorial is to teach you how to use the Vernier System to collect and transfer
EVAL-UFDC-1/UFDC-1M-16
Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1
MXG Dash Logger USER GUIDE
Dash Logger USER GUIDE AiM Srl. Via Cavalcanti, 8 20063 Cernusco S/N (MI) Italia Tel. (+39) 02.9290571 Made in Italy www.aim-sportline.com Dash Logger 04 06 08 10 11 12 12 12 14 16 17 18 19 21 22 23 23
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
QR12 (1.22 ) Diameter Optical Encoder
Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
Technical Note Series
Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
PDA Software Manual For the Windows CE and Mobile Operating Systems
PDA Software Manual For the Windows CE and Mobile Operating Systems Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560,
GV-VR605A DC Voltage Regulator
Video 1 GV-VS04H www.geovision.com.tw Video 2 Video 3 Video 4 Audio 1 Speaker Out /Audio 2 Reset Ready Disk Full/ Audio 3 Load Fault Default /Audio 4 DC Voltage Regulator The is a voltage regulator designed
MATRIX borehole logging system
MATRIX borehole logging system Combining their long experience in the slimhole logging industry Mount Sopris and ALT have teamed up to develop M A T R I X, providing a single solution to the multiplication
GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law
GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law OBJECTIVES: To verify Ohm s law, the mathematical relationship among current, voltage or potential difference, and resistance, in a simple circuit.
USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright 2005-2013 Pico Technology Limited. All rights reserved.
USB TC-08 Temperature Logger User's Guide USB TC-08 User's Guide I Contents 1 Introduction...1...1 1 Overview...1 2 Leg al information...2 3 Safety warning...3 4 Company details 2 Getting Started...4...4
HYDROSOFT Version 1.0.2 INSTALLATION AND OPERATING
HYDROSOFT Version 1.0.2 INSTALLATION AND OPERATING Overview The Hydrosoft software allows HG-302 controller users to monitor pool performance directly from a computer. As many as 32 controllers may be
Talon and Talon SR User Manual
Talon and Talon SR User Manual Brushed DC motor controller Version 1.3 Cross the Road Electronics, LLC www.crosstheroadelectronics.com Cross The Road Electronics, LLC Page 1 4/2/2013 Device Overview Clear,
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
USB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
MyChron Expansion User Manual
This user manual is copyright of Aim srl. All procedures here described can change even substantially. Please always refer to to know the latest procedures. Aim reserves the right of periodically updating
Inductors in AC Circuits
Inductors in AC Circuits Name Section Resistors, inductors, and capacitors all have the effect of modifying the size of the current in an AC circuit and the time at which the current reaches its maximum
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
2013 G Miller. 3 Axis Brushless Gimbal Controller Manual
2013 G Miller 3 Axis Brushless Gimbal Controller Manual P a g e 2 When you receive your 3 axis controller board from dys.hk in the packet will be the following items the sensor 3rd Axis board the main
HIGH RELIABILITY POWER SUPPLY TESTING
HIGH RELIABILITY POWER SUPPLY TESTING Dale Cigoy Keithley Instruments, Inc. The reliability of a power supply must match or exceed the rest of the system in which it is installed. Generally, this requires
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Parts List. Navigation
Parts List quantity description 1 LCD-200 Display 1 LCD-200 Display cable 1 CD-ROM 2 dual lock or velcro 1 1GB SD card (optional) 1 CAN termination plug Navigation Main Menu Begin Log/Stop Log page 4 Log
Manual Analysis Software AFD 1201
AFD 1200 - AcoustiTube Manual Analysis Software AFD 1201 Measurement of Transmission loss acc. to Song and Bolton 1 Table of Contents Introduction - Analysis Software AFD 1201... 3 AFD 1200 - AcoustiTube
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.
Multi- Channel Oven-Datalogger for Accurate Temperature Profiling in the Food Industry. ThermaPro 2 is the latest generation of high accuracy data logging instruments for use in extreme or hostile environments.
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
Cell Phone Vibration Experiment
Objective Cell Phone Vibration Experiment Most cell phones are designed to vibrate. But at what frequency do they vibrate? With an accelerometer, data acquisition and signal analysis the vibration frequency
Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples
Connecting Grounded and Floating Thermocouples For best performance, Thermocouple sensors should be floating. This will ensure that no noise currents can flow in the sensor leads and that no common-mode
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges
Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges 1. USB and Serial Communication Ports: Newer DG-700 and DG-500 gauges contain both a USB and a DB-9 Serial Communication Port,
FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER
2014 Amplifier - 1 FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER The objectives of this experiment are: To understand the concept of HI-FI audio equipment To generate a frequency response curve for an audio
Introduction. Page 2 / 9
Installation Manual English, US, version 1.1, as of November 13th, 2015 2015 Smappee NV. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their
How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit
User Guide USB Starter Kit AMS 5812 Phone:+49 (0)6131/91 0730-0 Fax: +49 (0)6131/91 073-30 Internet: E Mail: [email protected] Analog Microelectronics GmbH An der Fahrt 13, D 55124 Mainz May 2012 - Rev.
OEM-EP Pressure Controllers
Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable
NOVA MULTI-MONITORING SOFTWARE. Instruction Manual
NOVA MULTI-MONITORING SOFTWARE REMOTE OPERATION Precision Digital Corporation s Nova Multi-Monitoring software allows for the operation of common Nova control features remotely from a PC. Up to 30 Nova
PowerBox PBX 180. Installation and Users Guide
PowerBox PBX 180 Installation and Users Guide Firmware and Tool Version 060 7/14/2015 Table of Contents Table of Contents 1 Introduction... 4 2 Hardware... 6 3 Software Installation... 7 3.1 Software Installation
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Tube Liquid Sensor OPB350 / OCB350 Series
Features: Can identify if liquid is present in clear tubes that have an outside diameter of 1/16 [1.6mm], 1/8" [3.2mm], 3/16" [4.8 mm] or 1/4" [6.3 mm] Opaque plastic housing enhances ambient light rejection
User Guide Reflow Toaster Oven Controller
User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
GPS Fleet Setup Manual. Created by the team at FollowUs. A short documentation to get you started and setup with regards to the GPS Fleet
GPS Fleet Setup Manual Created by the team at FollowUs A short documentation to get you started and setup with regards to the GPS Fleet 8/2/2010 CE RoHS compliant A UK product 2 Important please read:-
Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE
Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and
Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.
Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current
External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)
Application: Heat quantity measurement This function calculates the heat quantity received and sent with liquid (water) in cooling and heating. Two 4-20mA inputs are available for temperature measurements.
REGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
1. Introduction... 3. 2.Fixture exterior view... 3. 3. Connecting the Robe Universal Interface... 4. 3.1 Software update of the fixture...
1 Table of contests 1. Introduction... 3 2.Fixture exterior view... 3 3. Connecting the Robe Universal Interface... 4 3.1 Software update of the fixture... 4 3.2 Connecting a DMX console to the Media Fusion...
INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.
2650-1706-00 INSTALLATION INSTRUCTIONS BOOST CONTROLLER WARNING! The installation of the Auto Meter Boost Controller is recommended only for experienced technicians. This product may damage your engine
Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
ADC-20/ADC-24 Terminal Board. User Guide DO117-5
ADC-20/ADC-24 Terminal Board User Guide DO117-5 Issues: 1) 8.11.05 Created by JB. 2) 13.12.05 p10: added 0V connection to thermocouple schematic. 3) 22.3.06 p11: removed C1. 4) 20.8.07 New logo. 5) 29.9.08
A-Series Data Loggers PRODUCT MANUAL
A-Series Data Loggers PRODUCT MANUAL Model # s A110, A125, A130, and A150 Contents Model Specifications 2 Connecting to the Computer 3 SpecWare Software 4 Installation and Placement 6 Battery Replacement
QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay
QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic
Bidirectional wireless communication using EmbedRF
Bidirectional wireless communication using EmbedRF 1. Tools you will need for this application note... 2 2. Introduction... 3 3. Connect EmbedRF Board to USB Interface Board... 3 4. Install and Run EmbedRF
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
EZIO-4THIE * External CJC Sensor** (National LM19)
TM E Z I/O EZIO-4THIE * Enhanced Thermocouple Input Module Part Number: EZIO-4THIE EZIO family offers two modules for interfacing to thermocouples: EZIO-4THI (not recommended for new applications) EZIO-4THIE
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
CB Svendsen A/S PS 2015.08.02/ rev. 1.5
CB Svendsen A/S PS 0.0.0/ rev... Description Installation guide for. The is designed for copying of signals from electricity-, heat- or water meters to s. This way, it is possible to connect a data logger
Workshop 7 PC Software - Tracker
Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
User Guide. QL40 GRA - Natural Gamma Ray Probe
User Guide QL40 GRA - Natural Gamma Ray Probe v12.12.13 Advanced Logic Technology sa Bat A, Route de Niederpallen L-8506 Redange-sur-Attert Luxembourg Phone : +352 23 649 289 Fax : +352 23 649 364 Email
Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels
Scanner Parts Document table Power cord Document cover Transparency unit (TPU) under lid Web Transparency unit (TPU) connector TPU indicator light e-mail Carriage and lamp (in the home position) USB port
Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited
Neo-Neon LED Vision Mesh Screen Operation Manual He Shan Decorative Lighting Company Limited LED Display Engineering Department 1 Contents Chapter1 Specification and Function Parameters 3 Chapeter2 Structure
MotorData. Car diagnostics made easy. MotorData Client Software User Manual
MotorData Car diagnostics made easy MotorData Client Software User Manual Legion-Autodata 2014 DIAGNOSTICS AND REFERENCE DATA SECTIONS 1.1 Connection to MotorData Web Service To start using MotorData System
FTDI VCP DRIVER (free) (WIN/MAC/LINUX) http://www.ftdichip.com/drivers/vcp.htm
002 - CONNECTING THE PRINTER Now that you have an idea what 3D printing entails, we can continue and connect the printer to your computer. First make sure you have a computer with a decent amount of RAM
Wireless Link. Introduction. Setup, Configuration and Connection ENGLISH
ENGLISH Introduction This document is an addendum to the HeartStart MRx Instructions for Use. It explains how to use the features of the HeartStart MRx s Wireless Link Option. The Wireless Link Option
Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,
Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified
E-Bike Conversion Kits Installation Manual Front Wheel
E-Bike Conversion Kits Installation Manual Front Wheel Contents ( 一 )Getting started... Page 3 ( 二 )Tools List. Page 4 ( 三 )Removing and Installation of the wheel.. Page 5 ( 四 )Install the hand brake.....
WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA
Thank you for purchasing the Maximum wind speed alarm. The Maximum wind speed alarm is a dual set point wind speed indicator with a two digit LED display. It contains a yellow light to display one set
Macs are not directly compatible with Noetix.
Those that use Macintosh computers to access Noetix cannot directly access Noetix through http://www.sandiego.edu/noetix. If one is on a Mac and goes to Noetix directly in a web browser, the page is likely
PC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700
PC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700 INDEX 1- Introduction 2- AGI-PRO Program Set-up 3- AGI-PRO Program Use 3.1- Interface Link 3.2- How Start AGI-PRO program 3.2-1. Page MONITOR 3.2-2. Page
Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
ICT Soft Logger. Solutions for soil, plant & environmental monitoring. www.ictinternational.com
Normally the MCC1 is used with the ICT Software to connect to an Instrument, configure the Instrument and download the data. However the MCC1 has other operating modes, one of which is the ICT Soft Logger.
I2C PRESSURE MONITORING THROUGH USB PROTOCOL.
I2C PRESSURE MONITORING THROUGH USB PROTOCOL. Product Details: To eradicate human error while taking readings such as upper precision or lower precision Embedded with JAVA Application: Technology Used:
ECU MS 3 Sport GT3 Cup. Quick Start Manual
ECU MS 3 Sport GT3 Cup Quick Start Manual V1.0 11/6/2015 Table of Contents Table of Contents 1 Welcome... 3 1.1 Hardware Checklist... 3 1.2 Hardware Installation... 3 1.3 Software Installation... 3 2 Tools:
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH
g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 [email protected], http://www.gtec.at Building a Simulink model for real-time
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
PoNET kbd48cnc. User s manual
PoNET kbd48cnc User s manual Version: 16/10/2012 SAFETY INFORMATION! This product is intended for integration by the user into a computer numerical control (CNC) machine. It is the user's responsibility
maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number 302287 Positioning Controller
control EPOS Positioning Controller Cable Starting Set Edition June 2006 24/1 part number 302287 Positioning Controller Documentation Cable Starting Set 1 Table of contents 1 Table of contents... 2 2 Table
Victoria Combo Remote Control
Victoria Combo Remote Control enables you to control your tester from any where in world. The only requirement is that the Victoria Combo and the PC are connected to TCP/IP networks either physically or