Local supplier shall be ISO 9001 & OHSAS 18001 Certified Company.



Similar documents
1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.

D45. SySTEm. ThE high-performance

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

video door entry system offer

Monitors. Platea Monitor

Video Kits. For Villas. Rock vandal resistant panel

GT Series. Multi-Tenant Security Intercom. Architectural and Engineering Specifications

Catalogue 05X english

XIGHTOR DOOR ENTRY SYSTEM. Company Name company address line 1 company address line 2

SECTION PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines

Bibus VOP: a system that defeats comparison from all points of view.

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

SFERA. NEw. 2 wire. audio ViDEO PUSHBUTTON PANELS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

TX3 Series TELEPHONE/CARD ACCESS SYSTEMS. System Introduction (Sales Training)

SATELLITE MASTER ANTENNA TELEVISION SYSTEM

NEW URMET INDOOR RANGE. Stylish lines, winning technology.

enter the smart house

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE

TELEPHONE ACCESS CONTROL ENTRY STATIONS

SECTION 3A (Rev.F) SECTION CONTENTS. Download from Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...

2013 Wireless Video Intercom INSTALLATION GUIDE

Honeywell Home Automation System Home Automation Solution

GT Series. Multi-Tenant Entry Security

The telephone has three soft-touch silicone rubber push buttons that can be backlit and each has a clear and precise function symbol;

Emergency voice communications Product Name

Security Systems Intrusion Alarm

TX3 Communication & Security Solutions

Company. During last year we have established ourselves as one of the main door system manufacturing companyís worldwide.

Honeywell Security. Honeywell Hello Series Video Door Phone System Product Catalog. Smile reaches your heart. Smile reaches your heart

2 WIRE video door entry system

LIFT CONTROL SYSTEMS CATALOGUE 2007

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

SECTION LOW VOLTAGE LIGHTING CONTROLS

axis axis AC TYPE 4 & 5 VIDEX TDE SYSTEMS AC TYPE 4 VIDEX ONE WAY TDE SYSTEM

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

Sound Engineering for 60 Years EmerCall Disabled Refuge and Fire Telephone System

Back-Up Camera Installation Guide

DTW Works Master Specification Version 2006

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Mounting and Operating Instructions. TV gateway

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

Fire Alarm System Plans Review Checklist Property location Date of Review

Spectra SP Expandable Security Systems

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

ACCESS CONTROL DOOR PHONES Installation and Programming Manual

GH Open Voice Audio & Video Series

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Reference Design. conference rooms

B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.

Audio and Video Door Entry System LIELBA - AD14

Add Door Phones to Your Phone System

Sympodium Interactive Pen Display

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Hortonville School District Door Control System Phase I Request for Proposal July 5th, 2013

Your door is all that separates your family from what lies outside

SECTION FIRE ALARM AND DETECTION SYSTEM

Examples of installations

System Manual 1+n technology

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

SECTION FIRE ALARM AND DETECTION SYSTEM

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

2 WIRE SYSTEM SFERA entrance panels

INSTRUCTIONS FOR URMET DOMUS DEVICE INTERCHANGEABILITY

VFS24/32HDIP. Public Display IP Monitor User Manual

SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Conventional Fire Detection and Extinguishant Control System Specification

C. Conform to requirements of Americans with Disabilities Act (ADA).

Cisco Smart+Connected Touchscreens for Property Developers

TESTING AND COMMISSIONING PROCEDURE FOR BURGLAR ALARM AND SECURITY INSTALLATION GOVERNMENT BUILDINGS THE HONG KONG SPECIAL ADMINISTRATIVE REGION

1838AP 1810AP PG. 48 PG. 42

DIGIVOICE. Large residential compounds with several entrances and stations with switchboard

LIFT CONTROL SYSTEMS CATALOGUE 2007

INTRUSION DETECTION SYSTEM Section

Polycom VVX Business Media Phones, Skype for Business Edition

ADVERTISEMENT FOR BIDS

How To Control A Knx System From Your Touch Panel

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

ONBACK. We Offer Full Systems, Monitors, Cameras and Accessories. Call Us Toll Free: Fax: Website:

B. Division 16 Basic Materials and Methods sections apply to work of this section.

Pancode VoIP/Pantel VoIP Access Control Door Phones. Installation and Programming Manual Release 1.0 June 2006

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

PS 155 WIRELESS INTERCOM USER MANUAL

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

JPSeries. 7-inch Touchscreen Intercom. Distributed by : JP(E)1411A. Printed in Japan (E) MA57036AJZ

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

AXIS 291 1U Video Server Rack Installation Guide

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

AC-115 Compact Networked Single Door Controller. Installation and User Manual

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Invitation to Bid FIRE ALARM & DETECTION SYSTEM

Transcription:

VIDEO INTERCOM SYSTEM Introduction: The contractor shall supply, install, test and commission a modern Electronic Digital Open Voice Color Video Entry Phone System of an approved manufacturer and design to facilitate Audio-Visual communication between the different apartments of the building and the main entrance. Local supplier shall be ISO 9001 & OHSAS 18001 Certified Company. System Parameter: The contractor shall submit a complete technical proposal with schematic drawings, list of materials and detailed catalogues of the equipment for consultant/client approval before starting the work. The video entry phone system shall be suitable for visual monitoring of the main entrance panel in lobby and duplex voice communication between the different apartments and the main entrance panel. The system shall be completely programmable at site from the main entrance panel without the need of any external programming devices or PCs. It shall be possible to back up the parameters and internal memory on PC/CD/DVD via built-in RS232 serial interface. The system shall be powered by a main power supply unit; additional power supplies shall be provided within the riser as the system demands; however, feeding each of the apartment monitors by a dedicated power supply unit will absolutely be rejected. Unlocking of building entrance door shall be possible by pressing the monitor's dooropener button. Standards & Codes: All the equipment and components shall be in accordance with CE Standards and they shall bear the EU Directives (89/336/EEC) label on them. Equipment Specification: The system shall consist of, but not necessarily be limited to the following: - Digital video intercom entrance panel with incorporated CCD camera and speech unit. - 7 LCD color monitor unit in each apartment. - Sufficient power supply units, signal distribution boxes, signal amplifiers, video cables and all necessary accessories.

Entrance panel: - The entrance panel shall be wall-mounted in stainless steel finishing. - Panel shall have 12-key matrix keyboard for selection of flat numbers with call and reset keys, in addition to up & down index scrolling and a help key. The buttons shall be back-lit; - Minimum memory capacity of 600 lines. - The panel shall have a dedicated key button for the watchman; - Panel shall operate on 8-digit encoding system; - Panel shall incorporate 2 line x 16 characters graphic monochrome LCD screen; - Incorporated 1/4" CCD camera with integrated speech unit. The camera shall have a minimum resolution of 480 TV lines, minimum of 1.0 lux when AGC on. - White LEDs for object lighting to ensure clear vision in total darkness; illuminated ENGAGED signal shall also be provided; - The panel shall have a full Arabic language interface for the instructions and help menus; Flush Mounted Monitors: - Flush-mounted 7 high-resolution wide-screen color LCD TFT monitor; 16:9 aspect ratio for wider field of vision. - Handsfree open-voice monitor. Conversation shall be carried our without the need of keeping the reply button pressed; - Monitor shall be equipped with dedicated push-buttons for self-start, stair light, door lock release and reply functions; - Green LED door open signal. - Clip-on interchangeable front panel frames in a range of different colours to the choice of the architectural engineer and interior designer; - Privacy function which disables the ringtone.

Power supply units: - Basic power supply units shall be in 12-DIN module thermoplastic housing provided with protective covers of removable terminal blocks. - Power supply units shall operate on 240 V, 50Hz with extra low-voltage output (13-18 V) for feeding all monitors along with the camera and videosignal splitters. - All outputs shall be stabilized and protected against short-circuits. - Call inhibiting circuit when system is in use. - Incorporated frequency modulated electronic call circuit. - Timed lock-release control and automatic disconnection device of monitor previously activated. - Incorporated indicator LED s for "power on", "door lock release control", "phonic line" & "auxiliary functions 1 & 2". - Integrated relay connection outputs for auxiliary functions. Cables: Video multi-conductor single cable shall be used for wiring the system. Cable shall consist of the following: Submittals: - 75 Ohm shielded coaxial cable. - 10 colored conductors. - PVC protection gray jacket. The contractor shall submit to the Consultant 4 Copies of Descriptive Literature, Technical Data, Catalogues, Installation Instructions and Maintenance recommendation of all the Products used. The Contractor shall provide detailed Shop Drawings for the review / approval by the Consultant which include the Schematic Diagram of the VI Distribution Network indicating all the System components like Splitters, Power Supplies, Cables etc.

Installation: - Video signal splitter shall be provided in each floor from which separate video cables should run to each monitor unit. - Video signal amplifiers shall be installed within the system, if necessary, to compensate the losses of the coaxial cables and to ensure good picture quality at all the monitors. - Correct number of power supply units shall be provided to fulfill the power requirements of the system. - In case of having different entrance panels at several gates, all audio/video & door-opening facilities will be switched to that particular gate from which the call is made. The controls at the other entrance panels shall be deactivated during the call till it is ended. MAINTENANCE: The system shall be warranted for a period of 12 months after final approval.

Bill of materials: No. Description Unit Qty Rate Total Open Voice Video Intercom System : Supply, installation & commissioning of Digital Open Voice Color Video Intercom System for the building as per the enclosed specifications : 1. 2. 3. 4. 5. 6. Digital color video intercom entrance panel with incorporated CCD camera and speech unit as specified. Flush-mounted open-voice electronic video intercom monitor with 7" color LCD screen and builtin electronic chime as specified. Power supply units as required for the system. Video cables. PVC junction boxes in the electrical/ telephone room of each floor of the building. Supply, installation, commissioning and warranty of the above system as specified with all necessary accessories.