1 Spectra SP Expandable Security Systems Control Panels Feature Comparison between Spectra SP Control Panels Feature SP4000 SP65 SP5500 SP6000 SP7000 StayD Maximum Zones 32 32* 32* 32* 32* On-board Zones 4 (8 w/atz) 9 (18 w/atz) 5 (10 w/atz) 8 (16 w/atz) 16 (32 w/atz) Expansion Zones (ZX8) 24 (3 x ZX8) 24 (3 x ZX8) 24 (3 x ZX8) 24 (3 x ZX8) 16 (2 x ZX8) Keypad Zones Partitions User Codes PGMs 12 (1 on-board) 16* (3 on-board) 16* (2 on-board) 16* (2+2** on-board) 16* (4 on-board) PGM +/- Trigger - (via BabyWare) - Alarm Relay ** 1 Events Buffered Remote Controls Wireless Keypads (K32RF and K37) Wireless Repeater (RPT1; see page 40) Wireless Siren (SR150; see page 36) Wireless Expansion Module (RTX3; see page 6) Wireless Receiver (RX1; see page 28) 2-Wire Smoke Detector Input Landline Dialer - GPRS/GSM Communication (PCS series; see page 12) Internet TCP/IP Communication (IP100; see page 13) * Any of which can be wireless ** Optional Only 1 partition with K636 keypad RX1 required Plug-in Voice Module (VDMP3; see page 13) (via PCS200) In-field Firmware Upgradable BabyWare Spectra SP Expandable Security Systems
2 Product Catalogue 2011 Spectra SP Control Panels SP4000: 4 to 32-Zone Control Panel Update: supports LCD keypads K32LCD and K32LX Supports StayD 4-wire expansion bus (connect up to 15 keypads) 4 zone inputs or 8 with zone doubling; expandable to 32 zones 1 on-board PGM Supports up to 16 PGMs 2 partitions (1 partition when used with K636 keypad) 32 user codes Supports GPRS and GSM Module (PCS series), IP Module (IP100), and Voice Module (VDMP3); see on page A switching power supply Menu-driven programming for the Installer, Master, and Maintenance codes Phone #s: 3 for monitoring station, 5 for personal dialing, and 1 for pager reporting Patented 2-optocoupler dialer circuit the most reliable dialer in the industry Automatic Daylight Savings Time feature Push-button software reset (reset to default values and restart) Direct connect at 9.6K baud with BabyWare 256 events buffered Supports REM3, one-way communication only (requires RTX3, V1.31 or higher) Supports RX1 Wireless Receiver, as well as RTX3 Wireless Expansion Module Fits in 20 x 25.5 x 7.6 cm (8 x 10 x 3 in.) and 28 x 28 x 7.6 cm (11 x 11 x 3 in.) metal boxes SP5500: 5 to 32-Zone Control Panel 5 zone inputs or 10 with zone doubling; expandable to 32 zones Direct connect at 9.6K baud with WinLoad Supports RX1 Wireless Receiver and RTX3 Wireless Expansion Module SP6000: 8 to 32-Zone Control Panel 8 zone inputs or 16 with zone doubling; expandable to 32 zones 2 (+ 2 optional) on-board PGM outputs, positive or negative triggering 1 alarm relay (optional) 1.5A switching power supply Supports RX1 Wireless Receiver and RTX3 Wireless Expansion Module SP4000 SP5500 SP6000 SP65 SP65: 9 to 32-Zone Control Panel Update: supports LCD keypads K32LCD and K32LX 9 on-board zones (18 with ATZ); expandable to 32 zones 3 PGM outputs No landline dialer (IP and/or GPRS only) SP7000: 16 to 32-Zone Control Panel 16 zone inputs or 32 with zone doubling; expandable to 32 zones 4 on-board PGM outputs, positive or negative triggering 1 alarm relay (optional) 1.5A switching power supply Supports RX1 Wireless Receiver and RTX3 Wireless Expansion Module Control Panels SP
3 Software iparadox Alarm System Control App Compatible with Spectra SP control panels See page 15 for full description BabyWare PC Software For SP series: compatible with SP4000 and SP65 See page 2 for full description WinLoad Installer Upload/ Download Software For SP series: compatible with SP5500, SP6000, and SP7000 See page 14 for full description InField Firmware Upgrade Software Upgrade tool for all Paradox firmware See page 2 for full description Hardwired Keypads TM40 Touch Interface Module Thin, sleek design Intuitive, icon-based interface via touchscreen, with quick menu-driven prompts 4.3-inch (10.9 cm) brilliant and vivid widescreen color display Compatible with EVO (V2.16 or higher), MG5000/MG5050, SP5500/SP6000/SP7000 (version 4.72 or higher), and SP4000/SP65 (version 4.90 or higher) Optional: supports up to 32 floor plans (EVO), or 8 floor plans (MG/SP) Optional: supports Annunciator mode (available Q4 2011) Customizable labels: zones, areas, users, and PGM outputs Controls up to 8 PGM outputs Supports WinLoad, not NEware External micro SD card slot for firmware upgrades and uploading photos etc. Built-in indoor temperature sensor 1 zone/temperature input to connect a detection device or exterior temperature sensor (TEMP07) Available in multiple languages Clean screen mode: locks screen for easy cleaning Display: 5.4 x 9.5 cm (2.1 x 2.7 in.) with a resolution of 480 x 272 pixels Surface-mount installation only; dimensions: 12.4 x 8.1 x 1.6 cm (4.9 x 3.2 x 0.7 in.) Available in 3 finishes: brushed aluminum, brushed black anodized, and brushed white anodized Home screen for MG/SP shown on White Anodized TM40 Annunciator mode shown on Silver Anodized TM40 Floor Plan screen shown on Black Anodized TM40 26 Spectra SP Expandable Security Systems
4 Features Common to All Hardwired Keypads Supports StayD 1 keypad zone input 8 one-touch action buttons Independently-set chime zones 3 keypad-activated panic alarms Connects to 4-wire expansion bus Compatible with Spectra SP, MG5000*, and MG5050* * The K32LX is not compatible with MG5000 and MG5050 K32LCD 32-Character Hardwired LCD Keypad 32-character, blue LCD with programmable labels Real-time zone alarm display (until disarmed) Menu-driven programming for easy system setup (installer and end-user) StayD status LED, contrast, and scroll speed K32LX 32-Character Hardwired LCD Keypad with Built-in Transceiver Same features as the K32LCD, along with the following: Built-in transceiver (433 or 868 MHz) Wireless range in a typical residential environment: 40 m (130 ft.) with SP4000/ SP5500/SP6000/SP K32LX keypad per system only Supports K32RF and K37 keypads Not compatible with MG5000 and MG5050 K35 32-Zone Hardwired Fixed LCD Keypad Fixed message display that guides you in the operation of the system Displays the status of 32 zones in 2 partitions StayD status icon Displays Arm, Sleep, Stay, and Disarmed status for each partition Displays troubles, bypassed zones, and alarm memory K32 32-Zone Hardwired LED Keypad 32-zone LED display StayD status icon Separate Arm, Sleep, Stay, and Off LEDs per partition Hardwired Keypads 27
5 K Zone Hardwired LED Keypad Single partition keypad 10-zone LED display StayD status LED Patented Key Light display (button illuminates to indicate an open zone) Arm, Sleep, Stay and Off keys illuminate to indicate partition status K10V and K10H Hardwired LED Keypads K10V: 10-Zone Hardwired LED Keypad (Vertical) K10H: 10-Zone Hardwired LED Keypad (Horizontal) 10-zone LED display StayD status LED Separate Arm, Sleep, Stay, and Off LEDs per partition Patented Key Light display (button lights up to indicate an open zone) K10V K10H Zone and PGM Expansion Modules RTX3 Wireless Expansion Module See page 6 or full description ZX8 8-Zone Expansion Module PGM4 4-Output Expansion Module See page 20 for full description See page 22 for full description RX1 Wireless Receiver Compatible with Spectra SP control panels (V4.54 and higher) 32 wireless zones Up to a maximum of 32 remote controls Compatible with remotes REM101, REM1, RAC1, and REM15 Compatible with transmitters DCT10, DCTXP2, DCT2, PMD1P, PMD75, PMD85, and SD738 In-field firmware upgradable via the InField Firmware Upgrade Software RF jamming supervision Low battery, tamper, and check-in supervision Transmitter signal strength display 2 PGM outputs correspond to buttons 1 and 2 on REM1, RAC1, and REM15 (also programmable through the panel) ZX8SP 8-Zone Expansion Module Compatible with the Spectra SP series, MG5000, and MG5050 Add up to 8 additional zones 1 PGM output Use zone input as an anti-tamper switch input 28 Spectra SP Expandable Security Systems
6 System Accessories PMC5 USB Memory Key Used to download or upload system programming to or from a PC, with WinLoad or BabyWare Lock-switch to prevent accidental loss of data LED status indicator Download or upload control panel/ console programming within seconds Connects directly to memory connector on the control panel/console No need for a phone line, PC, or other peripheral device HUB2 2-Port Hub and Bus Isolator Divides the communication bus into multiple, completely isolated outputs (if one output fails, the others will continue to function) 1 input port, 2 completely isolated output ports Each output port provides communication up to 900 m (3000 ft.) Compatible with EVO, Spectra SP, MG5000, and MG USB Direct Connect Interface Includes 3 LED status indicators (PC, Panel, and RX/TX) Incorporates a USB port and a serial port (DB-9) Enables control panel to communicate with a PC at a maximum distance of 60 m (200 ft.) Connects between panel s serial port connector to a PC s serial port (DB-9) or USB port 57.6K baud communication (Magellan console), 38.4K baud communication (EVO), or 9.6K baud communication (Spectra SP, MG5000, and MG5050) System Accessories 29
32-Zone Wireless Transceiver Security Systems MG5000 V3.2 MG5050 V3.2. 5- to 32-Zone Expandable Security Systems SP5500 V3.2 SP6000 V3.2 SP7000 V3.
32-Zone Wireless Transceiver Security Systems MG5000 V3.2 MG5050 V3.2 5- to 32-Zone Expandable Security Systems SP5500 V3.2 SP6000 V3.2 SP7000 V3.2 Always Armed, Never Disarmed Programming Guide PARADOX.COM
MG5000 V2.40 MG5050 V2.40 SP5500 V2.40 SP6000 V2.40 SP7000 V2.40. Reference & Installation
MG5000 V2.40 MG5050 V2.40 SP5500 V2.40 SP6000 V2.40 SP7000 V2.40 Reference & Installation We hope this product performs to your complete satisfaction. Should you have any questions or comments, please
GSM Communicator Module PCS100 V1.1
GSM Communicator Module PCS100 V1.1 Installation and User Manual Warranty Paradox Security Systems Ltd. ( Seller ) warrants its products to be free from defects in materials and workmanship under normal
32-Zone Wireless Transceiver Security Systems. 4 to 32-Zone Expandable Security Systems. Programming Guide. MG5000 Version 4.7 MG5050 Version 4.
32-Zone Wireless Transceiver Security Systems MG5000 Version 4.7 MG5050 Version 4.92 4 to 32-Zone Expandable Security Systems SP5500 SP6000 SP7000 Version 4.92 SP4000 SP65 Version 5.12 Programming Guide
Magellan All-in-one Wireless Security System
Magellan All-in-one Wireless Security System MG6250 Console Version 1.0 Menu Programming Guide Introduction The MG6250 All-in-one Wireless Console is a two-partition, 64-zone wireless console, offering
32 Zone Wireless Transceiver Security Systems MG5000 V4.0 MG5050 V4.0. 5 to 32 Zone Expandable Security Systems SP5500 V4.0 SP6000 V4.0 SP7000 V4.
32 Zone Wireless Transceiver Security Systems MG5000 V4.0 MG5050 V4.0 5 to 32 Zone Expandable Security Systems SP5500 V4.0 SP6000 V4.0 SP7000 V4.0 Always Armed, Never Disarmed Programming Guide PARADOX.COM
PCS250 - GPRS/GSM Communicator Module V1.0 Reference and Installation Manual
PCS250 - GPRS/GSM Communicator Module V1.0 Reference and Installation Manual PARADOX.COM Printed in Canada - 07/2012 PCS250-EI00 Table of Contents Introduction... 4 Features... 4 Overview... 6 System
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
MG5000 MG5050 SP65 SP4000 SP5500 SP6000 SP7000. User Guide. Always Armed, Never Disarmed
MG5000 MG5050 SP65 SP4000 SP5500 SP6000 SP7000 Always Armed, Never Disarmed User Guide Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on
http://www.ealarm.com.my
MG5000 MG5050 SP5500 SP6000 SP7000 Always Armed, Never Disarmed User Guide Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE Software Version 2.1
1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE Software Version 2.1 DEFAULT INSTALLER CODE 000000 (see section [281] on page 18) DEFAULT SYSTEM MASTER CODE 123456 (see section [301] on page 18)
PRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Ademco Vista-20P/First Alert FA-168C Basic Commands
Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel,
User Controls (Custom colours available, please contact us)
TM See page 3 for more information. 384 1000 64 Home Automation Partitions Controller Zones Users and Cards Doors Modules TCP/IP Built-In GPRS & SMS BabyWare V32 Imperial Controller Home Automation BabyWare
Always Armed, Never Disarmed User Guide
E55 E65 Always Armed, Never Disarmed User Guide Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your
High Security and Access System EVO48 V1.20 EVO192 V1.20
High Security and Access System EVO48 V1.20 EVO192 V1.20 Installation Guide Includes Keypad Installation We hope this product performs to your complete satisfaction. Should you have any questions or comments,
A VOLUTION. S series. Avolution S Series Security System. ASSA ABLOY, the global leader in door opening solutions
A VOLUTION TM S series Avolution S Series Security System ASSA ABLOY, the global leader in door opening solutions We know securing and safeguarding your home, family and your business is important to you
ABUS WIRELESS ALARM SYSTEM
ABUS WIRELESS ALARM SYSTEM These installation instructions are published by Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing/Mühlhausen. All rights including translation reserved. Reproductions
S100. GSM House Alarm System. Http://www.GSMalarmsystem.com
S100 GSM House Alarm System Http://www.GSMalarmsystem.com 1. Brief introduction The GSM Alarm System is a new security protection solution special for home, house and office and other applications. It
MOBILE CALL GSM alarm system
MOBILE CALL GSM alarm system User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Catalogue: Function Introduction 2 SMS Number
for DNE-K07 Reference and Installation Manual
for DNE-K07 Reference and Installation Manual TABLE OF CONTENTS INTRODUCTION...2 Specifications... 3 Navigation... 3 INSTALLATION...4 Viewing Angle... 4 Keypad Cover Clearance... 4 Mounting the Metal
Table Of Contents. System Monitoring... 14 System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...
Quick Start Table Of Contents Getting Started... 2 NEware Editions...2 Installing NEware...3 Installing Languages...3 Connecting to NEware...3 Changing Your IP100 Password...4 User Codes... 5 Master Feature...5
How To Set Up An M6250 Alarm System
Magellan All-in-one Wireless Security System MG6250 Console User Guide Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the Website www.paradox.com/terms.
EVO48 EVO192. User Guide
EVO48 EVO192 User Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments. Table of Contents
Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since 1997. automated production systems
Alarm Systems Agri-Alert alarms have been protecting swine operations across the world since 1997. Peace of Mind The Agri-Alert alarm system constantly monitors your operation and quickly notifies you
Intelligent GSM Auto-Dial Alarm System
Auto-dial Alarm System Intelligent GSM Auto-Dial Alarm System Profile For a better understanding of this product, please read this user manual thoroughly before using it. 2013.2.V1.0 Auto-dial Alarm System
GE Concord 4 Quick User Guide
GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide Page 1 Before Calling Is the keypad beeping? Press *. This will silence the beeping and let you know where the trouble is. Is there a flashing
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
SPECIAL CONTROL BUTTON FUNCTIONS
Operating Guide 1 2 3 CONTENTS Page No. OPERATING YOUR ALARM 5 General Information 5 Arming the Alarm 5 Disarming the Alarm 6 Arming in Stay Mode 7 Disarming Stay Mode 8 Bypassing Zones 8 Manual Panic,
Magellan All-in-one Wireless Security System
Magellan All-in-one Wireless Security System MG6250 Console Version.0 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed
LYNX Touch 5100 GRAPHIC TOUCHSCREEN WITH 4G/WI-FI COMMUNICATIONS, ANDROID TABLET AND Z-WAVE AUTOMATION. A Brilliant Way to Build Your Business!
LYNX Touch 5100 GRAPHIC TOUCHSCREEN WITH 4G/WI-FI COMMUNICATIONS, ANDROID TABLET AND Z-WAVE AUTOMATION A Brilliant Way to Build Your Business! New Technology Breakthrough from Honeywell! The industry s
Application Notes. 1.21 Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4.
Application Notes 1.21 Partition Programming (PC1616/1832/1864 V4.2) Panels: POWER SERIES (PC1616/1832/1864 V4.2) Overview: The PC1616 supports 2 true partitions. The PC1832 supports 4 true partitions.
System Manager s Manual
LCD Keypad DGP2-641B / DGP2-641RB DGP2-641 / DGP2-641R System Manager s Manual Also includes Operating Instructions Table of Contents Introduction... 1 Legend... 1 Basic Operation... 1 Auditory Feedback
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions
TM SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS Quick Start Instructions Introduction WinLoad for Windows was developed to simplify and speed up the task of programming Paradox control panels. Remote
EVOHD. Installation Guide. Includes Keypad Installation. Version 1.11. www.paradox.com
EVOHD Installation Guide Includes Keypad Installation www.paradox.com Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on our Web site: www.paradox.com.
Reference & Installation Manual
& Versions 4.4 (728ULT) & 4.1 (738ULT) 728ULT 738ULT Reference & Installation Manual Table of Contents Introduction... 1 About This Manual... 1 New Features... 1 Main Features... 1 Specifications... 1
GSM home alarm system s manual
GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.
GSM ALARM SYSTEM USER MANUAL
GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
FA701 Series. User s Guide. K6249-2V2 5/09 Rev. A
FA701 Series TouchCenter Keypads User s Guide K6249-2V2 5/09 Rev. A Table of Contents ABOUT THE TOUCHCENTER... 5 Introduction... 5 2 The TouchCenter Interface... 5 Navigating through the TouchCenter...
Alliance System Ordering Guide
Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers
IPR512: IP Monitoring Receiver Getting Started
PR512: P Monitoring Receiver Getting Started The following instructions explain the basic connections and programming required to get your Paradox P Monitoring Receiver up and running. They also guide
VISTA Plus Series INFORMATION FOR SECURITY DEALERS. Build Your Business with VISTA... the Industry s Leading Residential Control
VISTA Plus Series INFORMATION FOR SECURITY DEALERS Build Your Business with VISTA... the Industry s Leading Residential Control Take Control of Opportunity! There s a reason Honeywell s VISTA Plus Series
A) Power light: On = AC power Off = Power failure Flash = System is locating the keypad A 6
K07C: Grafica Color Keypad Quick Start Description Grafica sets a new milestone for keypads in the security industry. Grafica features a full color LCD screen and offers the ability to view zone locations
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by
Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by providing quality, innovative products and solutions to the
LCD and 16-Zone LED Keypads. User s Manual
LCD and 16-Zone LED Keypads 1689 1641 16-Zone LED Keypad LCD Keypad User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION...3 2.0 BASIC OPERATION...4 2.1 Keypad Indicator Lights... 4 2.2 Visual Feedback...
Quick Installation Guide LCD GSM ALARM SYSTEM LH http://www.usmartbuy.com
A. Manipulation Specification Quick Installation Guide 1. Arming Arming means all-around guarded when there is no person at home. All detectors are working. Once something triggers any of the detectors,
IDS X-Series User Manual 700-398-01D Issued July 2012
1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...
WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness
WIRING HARNESS FOR AS635P4 ANTENNA NOT USED 5 PIN WHITE PLUG 2 PIN WHITE PLUG GREEN - PARKING BRAKE INPUT (-) BLUE - NOT USED 3 PIN BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness
Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand
Elite 8D/Lite Version 8 Zone Controller 8 Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand 2 CONTENTS Page No. INTRODUCTION 4 About your Alarm 4 OPERATING
Solution Ultima ICP-CC488 Home security you can rely on
Solution Ultima ICP-CC488 Home security you can rely on Keeping your home and family safe doesn t need to be complicated. That s why we ve made the Ultima security system so easy to use all it takes is
LYNX. The Best in Wireless Home Security...
LYNX The Best in Wireless Home Security... ...without compromise. Sleek, smart and sophisticated, LYNX provides the installation ease you need with the features your customers want. Designed with both
APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS
APPLICATION NOTE Contents The DMP Software Family... 1 Stand-Alone Link Software... 1 Add-on Modules for Link Software... 1 System Link End-User Panel Management Software... 2 Simple Registration and Activation...
User's Manual. For use with ProSYS 16, ProSYS 40, and ProSYS 128
User's Manual For use with ProSYS 16, ProSYS 40, and ProSYS 128 Important Notice This manual is delivered subject to the following conditions and restrictions: This manual contains proprietary information
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
User Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd
User Manual GSM Alarm System All rights reserved by Delta Security Co., Ltd Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
DC-8706K Auto Dial Alarm System
DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power
Solution Ultima ICP-CC488 Home security you can rely on
Solution Ultima ICP-CC488 Home security you can rely on Keeping your home and family safe doesn t need to be complicated. That s why we ve made the Ultima security system so easy to use all it takes is
Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.
Innovative GSM & WIFI dual network operating platform. On WIFI network, the alarm system will work without any fee. If no WIFI, it will work on GSM automatically. With state-of-the-art WIFI network technology,
CS848E Receiver for 868GEN2 Devices Installation Sheet
CS848E Receiver for 868GEN2 Devices Installation Sheet EN 1 2 1 3 4 2 3 EN: Installation Sheet Description The CS848E Receiver adds wireless capabilities to the CS line of control panels. The CS848E allows
Six-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks
Go!Control Panel Installation & Programming Guide
Go!Control Panel Installation & Programming Guide Firmware Version 1.12 ENGLISH WARNING: OWNER S INSTRUCTION NOTICE Not to be removed by anyone except occupant THIS PAGE INTENTIONALLY LEFT BLANK CONTENTS
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
Security with you in mind. As your needs change, NetworX security systems grow with you.
Security with you in mind. As your needs change, NetworX security systems grow with you. Advanced wired and wireless components to form a leading security system. Hard-wired Wireless Carbon Monoxide Detector
tattletale User Guide Consumer unit version 2.48 1 P a g e
tattletale User Guide Consumer unit version 2.48 1 P a g e Contents Basic 1... 4 Base Unit Features... 4 Initial Setup... 4 Arming... 5 Disarming... 5 Quiet Button... 5 Settings... 5 Settings 2... 6 Quick
Control/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
Expandable serial alarm system
Expandable serial alarm system The TP- system represents the state-of-the-art of Tecnoalarm philosophy and technology. The extremely versatile and expandable system offers solutions for any kind of application
How To Control A Control Panel With A Pager And A Power Control Unit
V1.5 96-Zone Expandable Security and Access Control Panel DGP-NE96 DGP-NE96 Reference and Installation Manual www.paradox.ca Table of Contents Introduction... 1 Features... 1 Specifications... 1 Installation...
PiSector Home security systems
PiSector Home security systems User Manual (ALM-S02) Read manual fully before use. PiSector Inc., USA, www.pisector.com Thank you for purchase this alarm system, For proper use and your safety, please
Wireless Auto-dial Intruder Alarm System
Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.
Business/Home GSM. Alarm System(III) Installation and Users guide
Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment
DESTINY 1/19/96 # 800-6006A
DESTINY TABLE OF CONTENTS KEYPAD AND PHONE DIGIT QUICK REFERENCE NOTE: KEYPAD AND PHONE DIGIT QUICK REFERENCE POWER STATUS HOME AWAY MONITOR DESTINY INTRODUCTION CONTROL PANEL DETECTION DEVICES SWITCHES
Product Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS
AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT ALARM SYSTEMS Peace of Mind Agri-Alert is a complete alarm system for monitoring temperature, power, feed and watering systems, burglary,
GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL. GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System
GSM INTRUSION ALARM SYSTEM INSTRUCTION MANUAL GSM - PSTN - SMS - TOUCH GSM Wireless Security Alarm System SECURE YOUR HOME AND BUSINESS Printed in Shenzhen RE: G60-GSM-August-2013 Key Features Smart touch
Magellan All-in-one Wireless Security System MG6250 Console. User Guide
Magellan All-in-one Wireless Security System MG6250 Console User Guide Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the Website www.paradox.com/terms.
IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited
(Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device
FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
Business/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
Iphone & Android App Smart GSM Home Alarm System
Iphone & Android App Smart GSM Home Alarm System PST-GA242Q User Guide Version V14.3 Dear User, Thanks for selecting the intelligent alarm system. Please read through this guide before installation so
Digiplex Control Panel (DGP-848) - V4.1
Digiplex Control Panel (DGP-848) - V4.1 DGP-848 Reference and Installation Manual Includes DGP2-641BL/RB Installation Instructions Table of Contents Introduction... 1 Features... 1 Specifications... 1
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
Security GSM Alarm System
KONLEN TECHNOLOGY LIMITED Website: www.konlen.com Add:, 3/F, Building5, Kaijieda Industry Zone, Huachang Road, Longhua, Shenzhen China Tel: +86-(0)755-29709632 E-mail: [email protected] [email protected]
NOTE: The home screen always displays the day and month, time, & P1 (Partition 1)
GE Concord 4 System NOTE: The home screen always displays the day and month, time, & P1 (Partition 1) STAY AWAY DISARM The Asterisk key on your user interface pad is the most commonly used key. This is
Serenity s Web & Mobile Remote Access Concept
Serenity s Web & Mobile Remote Access Concept Communication Concept INSTALLATION Panel first connection Panel first connection The Serenity is supplied with unique serial number and Mac Address (factory
1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between
EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE
EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE You can program online 24/7 giving you the freedom to work when and where you want. From remote bookkeeping and access, to security control on the ground
LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets
LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
All-In-One Wireless Console (MG6130 / MG6160) User Guide
All-In-One Wireless Console (MG6130 / MG6160) MG6130 User Guide MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com
Solution 144 The Integrated Access Control & Alarm System made for your business
Solution 144 Access Control & Alarm System 1 Solution 144 The Integrated Access Control & Alarm System made for your business The Solution 144 Integrated Access Control & Alarm System offers an extensive
728 SERIES REFERENCE & INSTALLATION MANUAL 728+ VERSION 3.2. 728 series
728 SERIES 728+ VERSION 3.2 728 series REFERENCE & INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION... 2 About This Manual... 2 Features... 2 Specifications... 3 Accessories and Keypads... 3 About Paradox...
Security Alarm - Fire Alarm system Central Monitoring Services Promotion Packages