Reference Design. conference rooms
|
|
|
- Deborah Floyd
- 10 years ago
- Views:
Transcription
1 Reference Design conference rooms
2 Tomaro Design Group conference rooms The modern commercial conference room embraces communication and multi-media technology from projectors and video conferencing, to automated shades and screens and even interactive whiteboards. In addition, the conference room may be the only room guests or customers are exposed to within the company. For these reasons the lighting and control systems in these spaces need to be well designed and intuitively controlled. Lighting scenes need to be pre-configured but adjustable so multiple users can easily change the settings for their particular meetings. The system should be powerful enough to control all the electronics in the space with just the press of a button on a touchscreen. The right system should take the complexity of the conference room and control it using only a few well configured scenes.
3 APPLICATION DESCRIPTION SPACE USE ACTIVITIES DIMENSIONS CEILING HEIGHT WINDOWS LIGHTING LIGHTING APPS Conference Room 20 x Along One Side of Room Direct and Indirect Fluorescent, Cans, Cove, 0-10V and Forward Phase Dimming Full On, Presentation Mode, Daylighting CONTROL NEEDS & SOLUTIONS LIGHTING INTERFACE SENSORS AUDIO/VIDEO SHADES INFRASTRUCTURE Dimming, presentation mode, daylighting, occupancy sensor. (n.1) Equinox 40 control station at entry, single load control and lighting scenes. (n.2) Light sensor for daylighting, occupancy sensor for energy management. (n.3) Tie in for controlling projection screen (low-voltage relay), IRX II for control of projector and audio/video switching. (n.4) Low Voltage Relay or RS-485 for shade control. (n.5) InFusion Controller in a surface mounted enclosure or a DIN controller. Remote located LVOS Station for 0-10 control or Power Boosters/ScenePoints for forward phase control with an LVOS station and an Equinox station, the entire system can be wired via Cat6/ Ethernet. (n.6)
4 <SERIALNUM.> CONFERENCE ROOM FLOOR PLAN MOTORIZED SCREEN 6 PROJECTOR 5 MOTORIZED SHADES
5 Crowne Plaza Hotel DESIGN CONSIDERATIONS The Vantage System allows for complete control over the conference room environment. Preset scenes for presentations and meetings can incorporate the control of lighting, motorized shades, motorized screens, projectors and A/V systems, sensors and temperature. With the press of one button on the Vantage Equinox 40 keypad, you can lower the shades, dim the lights, drop the screen and power up the projector in preparation for a presentation or meeting. Occupancy sensors allow for energy savings as lights can turn off and comfort settings can be set back based on the room being empty. Light sensors can help control and maintain the level of light in the room to take full advantage of natural light during meetings.
6 IR1 IR2 IR3 IR4 STATUS/ON ETHERNET PORT 1 PORT 2 <SERIALNUM.> LVRS8-DIN MAX RATINGS 1AMP 48VAC 30VDC RE RE RE STATION BUS CLASS 2 LOW VOLTAGE RELAY STATION 8 - DIN OPEN ENERGY MANAGEMENT EQUIPMENT 51XT RE RE RE RE RE SERIAL NUMBER STATUS WIRING DIAGRAM AUDIO/VIDEO RACK ELECTRICAL ROOM WIRE LEGEND Unswitched Power Switched Power Station Bus Ethernet Speaker Wire Balanced A/V Misc. (as labeled) CONFERENCE ROOM USER SOURCE USER SOURCE USER SOURCE USER SOURCE ETHERNET TO PREMISES LAN LIGHTING LOADS SENSORS ETHERNET TO PREMISES LAN Each InFusion Controller to have separate dedicated circuit breaker Main feed to circuit breaker panels furnished and installed by electrical contractor All lighting circuits shall be fed by 20A line feeds and load wires shall be wired with 12AWG wire SHADES / PROJECTION SCREEN
7 BILL OF MATERIALS CATEGORY PART NUMBER DESCRIPTION QTY Enclosures ISME-24 InFusion Surface Mount Enclosure 24V 1 Controller IC-24-1 InFusion Controller - 24V Station Bus 1 Load Control LVOS-0-10-PWM Low-voltage 1-10 PWM Station (with Enclosure) 1 Sensors EM-LIGHTSENSOR Ambient Light Level Sensor 1 FL-MS-MINI PIR Motion Sensor - 16 ft Radius 1 VDA-0015 Auxiliary Pigtail Cable Assemblies Each 1 Equinox Control Stations EQUINOX40 Equinox 40 Control Station 1 Integration/Misc LVRS8-DIN Low-voltage Relay Station 8 - DIN 1 Distributed Audio/Integration 850D-DA 12x8 Digital Distributed Audio Amplifier 1 IRX II Infrared Emitter Station with RS32 1
8 INSTALLATION NOTES Install the InFusion Controller remote from the conference room in a temperature conditioned electrical closet. Vantage two conductor station bus cabling is run from the controller to keypads and thermostats. Topology is completely open but total bus length limitations and maximum distance limitations exist (2000 maximum per bus, 1000 maximum distance). Occupancy sensors wire either to low-voltage keypads or Equinox 40s via 22AWG cable, with a minimum of three conductors. Thermostats are located remotely with local flush wall-mount temperature sensor (maximum run 160 ft, 18AWG 2C). A variety of window shade motor control options exist. Whether line voltage or lowvoltage, direct drive or serial port controlled, the hardware to affect the solution will vary accordingly. Vantage 850D-DA and IRX II connected to Premises LAN via Cat6, on the same network as the InFusion Controller. IRX II is used for control of audio sources (provided by integrator) such as satellite radio, ipod docks, music library devices, tuners, CD players. Speaker placement and zones to be specified by the integrator based on the requirements of the management. An Ethernet port to the InFusion Controller allows for centralized and remote system access as well as enabling interface apps on fixed location and portable devices. LVOS Station for lighting can be remotely located with the InFusion Controller, or centrally located in a ceiling or crawl space in the conference room. LVOS station connected to Vantage controller via 16/2 station bus, or Cat6. Alternatively, Power Boosters or ScenePoints can be used for lighting load control and are located centrally in the room, or remotely.
9 1061 South 800 East Orem, Utah fax The content in Vantage reference designs for conference rooms is intended to provide a starting point for designers anticipating a project including conference rooms with lighting control and integrated automation. The photos included, unless labeled, are not exact project replicas but are representative of this type of project by Vantage. All Rights Reserved. Part# Rev_A DM/DC 6/13
C-Bus Solutions. Complete commercial control. Make the most of your energy SM
C-Bus Solutions Complete commercial control Make the most of your energy SM Complete Control C-Bus control systems from Schneider Electric will put you in control of your lighting levels, your comfort,
GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS- - - - - - SpaceBuild Specification Worksheet. Touch Screens
SpaceBuild Specification Worksheet GLPHASE System The GLPHASE SpaceBuilder system is ideal for medium-sized spaces that require additional options such as expansion modules for more load types, touch screens,
MechoNet TM Network Interface (MNI) Specification Submittal
MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)
The Consumer Electronics Association TechHome Rating System Guidelines
The Consumer Electronics Association TechHome Rating System Guidelines The TechHome Rating System (THRS) is a powerful new nationally-recognized build-to specification for residential technology infrastructure.
Lighting Management solutions
Lighting Management solutions Best practice guide for office buildings PUTTING A STOP TO ENERGY WASTE INTRODUCTION Table of contents 1 Lighting control Best Practice Guide for Office Buildings 2 Guide
High Bay Occupancy Sensor Selection Guide
High Bay Occupancy Sensor Selection Guide Make the most of your energy SM 1 2 Schneider Electric offers a vast array of lighting control sensors for HID and Fluorescent High Bay applications. HID High
Commercial Solutions
Commercial Solutions Automation means better business Rely on a trusted solution to control lights, temperature, audio/video, teleconferencing, security cameras, and HVAC systems to make your business
How To Use A Lutron Power Supply
Dimming Module Dimming Power Module for 3-wire Lutron Dimming Ballasts 16A Module-1 09.27.07 Power Indicator (PW) Indicateur de puissance (PW) Indicador de Alimentación (PW) Status Indicator () Indicateur
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
A1.5 Classroom Standards
A1.5 Classroom Standards Note: The following standards have been developed and adopted by KU's Instructional and Mediated Spaces Committee (IMSAC), which includes representatives from DCM, Instructional
Climate Ready Control Systems Technical Specifications
Climate Ready Control Systems Technical Specifications Climate Ready Control Systems Climate Ready Control Systems consist collectively of motor controllers, other hardware and software packages that will
Controller board and power supply for vivimat III systems
Controller board and power supply for vivimat III systems Ref: VIVIMAT-3.0 The controller board and power supply vivimat 3.0, is the central core of the vivimat III home automation system. The vivimat
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module
EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron EcoSystem dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron EcoSystem bus
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline
Temperature Control from Lutron
TouchPRO Wireless thermostat seetemp wall control in White Temperature Control from Lutron Home Control+ app Use Lutron s Home Control+ app to manage your home s temperature while at home or while you
overview DyNet over RS485
technical guide systems integration overview Integration between various control systems within projects, reduce end-users need to have multiple interactions to perform what seems like one task such as
HDCATS-100. Installation Guide
HDCATS-100 Installation Guide 1 Contents Description... 3 Features... 4 Application Diagram... 4 Installation... 5 Local HD port... 6 IR Configuration... 7 Serial Data(RS232)... 8 Ethernet Data... 9 Specifications...
The Fully Integrated Home
The Fully Integrated Home Adding Safety and Convenience to the Home 2008 National Association of Home Builders International Builders Show Introduction Josh Christian Marketing VP of DSI Entertainment
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
How To Set Up A Minipatch System For A Small Office Or Home Use
Issue : 4 Wood Communications Networking Products Catalogue Small Office & Home Solution Small Office / Home Solution Min LAN Comms Cabinets - Multimedia Panel - Soho Ethernet Switches - Multiroom Audio/Video,
LIGHTING CONTROL SYSTEM
LIGHTING CONTORL SYSTEM LIGHTING CONTROL SYSTEM Intelligence to the n th Degree Close your eyes and imagine A lighting control system with intelligence that is distributed throughout a building Lighting
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
8 Channel Status Input Panel model SIP-8
Description The Sine Systems model SIP-8 Status Input Panel is to be used with the RFC-1/B Remote Facilities Controller. It consists of a long PC board mounted on a 1.75 inch (1U) rack panel. The SIP-8
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
Matrix Fitness 7xi Setup and Network Connection guide
Matrix Fitness 7xi Setup and Network Connection guide Introduction: Please note that this guide is meant to provide an overview on the configuration and setup steps that are unique to the 7xi product.
Passion for Innovation
Passion for Innovation A Complete Solution Hardware All the Alveo servers are designed and optimized to manage the home automation system. They arebuilt for continuous operation with fanless processing
Niko Home Control. Installation Manual
Niko Home Control Installation Manual Niko Home Control: Table of contents Warnings regarding installation...2 Guarantee provisions...3 CE...4 Key of symbols...5 1. Installation preparations...6 2. Controller...8
Blue 2.2.25 Conference Room
Blue 2.2.25 Conference Room Introduction This section introduces users to basic system operation procedures using the touch screen. Sections 2.2 and 2.5 detail the start-up and shutdown procedures; the
Middleborough Police Electronic Security Narrative
Middleborough Police Electronic Security Narrative 1. PURPOSE The purpose of this document is to define specific security, access control and surveillance requirements for the exterior and interior of
WALL TABLET. Smart Home Controller. make your home smart. Control your home from anywhere in the world
WALL TABLET W I T H WA L L C H A R G I N G S TAT I O N Smart Home Controller Control your home from anywhere in the world WALL TABLET Connect everything Makes every home safe, comfortable and energy efficient
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
Special software can be created for you specific requirements: Lutron Light system, Conson Light System and more
Infrared Receivers (IR-FUGA series) The IR-FUGA series of InfraRed Receivers is designed for 38 and 455 KHz remote controls, which allows you to remote control your computers MP3 music, Mailbox, programs,
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
APPLICATION GUIDE MINI PRODUCT GUIDE
MINI PRODUCT GUIDE BETTER PERFORMANCE THROUGH ADVANCED TECHNOLOGY 100% Digital Passive Infrared (PIR) Detection Dual Technology Detection utilizing Microphonics Contractor Friendly Wiring Features MICROPHONICS
FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223
FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data
RadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! 6.4.200 RadioRA2 Inclusive Software v5.0.8 or newer
Manufacturer: Model Number(s): Minimum Core Module Version: Comments: Lutron Document Revision Date: 8/5/2013 OVERVIEW AND SUPPORTED FEATURES Integration Note RadioRA 2 (QS) Lighting and Climate Control
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
HomeWorks QS Processor
product specifications 369-376 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems and communication
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
EVOline Multimedia Modules
243 EVOline VGA cable EVOline DVI-A cable EVOline DVI-D cable EVOline HDMI cable Cable properties Flame retardant self extinguishing VW-1 Halogen free yes yes yes Colour Black Black Outer diameter 7,2
ICANN Remote Participation Hub Technical Documentation
ICANN Remote Participation Hub Technical Documentation Revised: 2015-08-26 JTB Remote Hub Technical Documentation Page 2 Remote Participation In order for groups of individuals to remotely participate
BACnet Automation Interface Module (Network Version)
Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
Smart home solutions
Smart home solutions Living life, automatically Imagine. One touch on your tablet and the movie starts, your shades close and the surround sound kicks in at the perfect volume. When the sun goes down,
AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH
158 Audio/video receiver ENGLISH Quick-Start Guide 158 Introduction, Speaker Placement and Connection Introduction Thank you for choosing a harman kardon product! This quick-start guide contains all the
Passion for KNX innovation
Passion for KNX innovation Touch-MyDesign 2 Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building thanks to its total customization: Everyone can
NYC Department of Education Building Condition Assessment Survey 2014-2015 P.S. 64 (OLD 71) - MANHATTAN, 600 EAST 6 STREET, MANHATTAN, NY, 10009
School: InspectionId Asset Data Inspection Type Building Assessment Survey 204-205 P.S. 64 (OLD 7) - MANHATTAN, 600 EAST 6 STREET, MANHATTAN, NY, 0009 Time In Last Edited 095 ELECTRICAL 205-0-6 08:45AM
One Room One Cable Architectural Specification
One Room One Cable Architectural Specification ORC-1: One Room One Cable Kit: The ORC-1 One Room One Cable Kit shall consist of one (1) DXW-2 Wall Plate switcher, one (1) DXE-CAT-RX3-A HDBaseT Receiver
Appendix 3H A/V and Video Conferencing Standard
Appendix 3H A/V and Standard 1. Introduction The Authority uses meeting and conference rooms for a variety of purposes. All new construction will have a mix of each type of room type as identified below.
CEDIA Electronic Lifestyles Awards Program Home Technology Professional Categories Technical Criteria for Judging
CEDIA Electronic Lifestyles Awards Program Home Technology Professional Categories Technical Criteria for Judging Home Theater, Media Room, Media Room Under $25,000 Layout (15pts) o Considering the space
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS 1 DORANI VIDEO INTERCOM - 2 WIRE SERIES 7 TFT MONITOR TECHNICAL SPECIFICATIONS 7 Colour TFT screen 480 x
Contact Center CC-165 INSTALLATION & USER'S GUIDE
Contact Center CC-165 INSTALLATION & USER'S GUIDE Table of Contents Introduction... 2 Specifications... 2 J4 Host Communications... 2 J5 and J12 (upper board)... 3 J6, J13, and 14 Input Connections...
VOIP-500 Series Phone Quick Installation Guide
I. Introduction This provides instructions for installation of the VOIP-500 Series Phone. It is recommended to read this instruction set completely before starting any installation. II. Contents Please
GRX-PWM Pulse Width Modulation Interface
Pulse Width Modulation Interface pwm1 05.30.06 COOPERSBURG, PA 18036 U.S.A. Coopersburg, G 8 BR PA 18036 U.S.A. 144317 GRXTVI 19 P10 CB 0791275 Ratings Load T ype Switched Lowvoltage Load Type Switched
- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).
Page 1 of 30 Page 2 of 30 1. Basic terminology - Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF). - Remote Element:
GOVERNMENT HEALTHCARE RETAIL
ENERGY MANAGEMENT INTEGRATED AV CONTROL & AUTOMATION VIDEO WALLS & DIGITAL SIGNAGE CORPORATE EDUCATION HOSPITALITY GOVERNMENT HEALTHCARE RETAIL HOUSE OF WORSHIP ENTERTAINMENT LUXURY TRANSPORT Contact us
Local supplier shall be ISO 9001 & OHSAS 18001 Certified Company.
VIDEO INTERCOM SYSTEM Introduction: The contractor shall supply, install, test and commission a modern Electronic Digital Open Voice Color Video Entry Phone System of an approved manufacturer and design
Examples of installations
Examples of installations Video door entry, automation and burglar alarm Row house The example shows the integration of the automation and burglar alarm system with the Sound System video door entry system,
Honeywell Security. Honeywell Hello Series Video Door Phone System Product Catalog. Smile reaches your heart. Smile reaches your heart
Honeywell Security Smile reaches your heart Honeywell Hello Series Door Phone System Product Catalog Smile reaches your heart Honeywell Security, Your Partner of Choice! Commitment Constant Innovation
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
Broadway 3D Security System
Broadway 3D Security System USER MANUAL v.1.1.0 Artec Group, Inc. 2012 Table of contents 1. General Information... 3 2. Delivery Package... 4 3.1. B3D BR... 5 3.2. B3D B... 6 3.3. B3D BM... 7 4. Integration
Trinchero Family Estates Building: Operation User s Guide
Trinchero Family Estates Building: Operation User s Guide Heating Ventilating and Air Conditioning Controls The building air handlers operate in accordance to a pre programmed software time clock. They
Optimize your simple machines... Modicon M218 Selection Guide
Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,
1.1 The Audio Entry Phone System shall be suitable for 2 way voice communication between the different apartments and the main entrance panel.
DIGITAL AUDIO INTERCOM SYSTEM The contractor shall Supply, Install, Test and Commission a modern Audio Entry Phone System to facilitate Audio Communication between the different apartments and the building
Future proof lighting management
Future proof lighting management LightMaster Modular Lighting Management for today s fast changing world LightMaster Modular is a new building block concept in lighting management systems designed to
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface
Advanced Power over Ethernet Controllers Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER Gigabit PoE Ports Intuitive Configuration Interface Advanced Switch Management Features Advanced Gigabit PoE Managed Switch
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
Production analogue video fed to Granicus encoder currently place Phase 3 will provide digital audio video to Granicus encoder
The City has received questions regarding the recently distributed RFEI - CPM Council Chambers A/V System Replacement Answers have been provided below supporting documents and photos have also been provided
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Introduction. Page 2 / 9
Installation Manual English, US, version 1.1, as of November 13th, 2015 2015 Smappee NV. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their
Imagine, a sound system that fills every room with crystal clear music & offers unequalled performance, flexibility & simplicity.
Imagine, a sound system that fills every room with crystal clear music & offers unequalled performance, flexibility & simplicity. Crafted with love, built to last... every room, your music Asano is a networked
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
A smart home is a brilliant idea
A smart home is a brilliant idea The automated life used to be the exclusive realm of the rich. Now home automation is coming to a subdivision near you. WIRED Issue 13.01 What is home control? oducts ted
Climate Ready Shade Operating Systems for residential applications.
Climate Ready Shade Operating Systems for residential applications. This brochure contains examples of home plan configurations and how Climate Ready Shade Operating Systems can be applied and what is
HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL)
DATA SHEET HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL) Overview With space for up to 12 modules, the HPX-1200 allows you to
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
Product Specifications Dialog System
1 1. PART 1 - General Product Specifications Dialog System 1.1 Overview Provide a complete low voltage lighting control system for the building as shown on the plans and specified herein. Lighting control
A/V and Video Conference Standards for Teaching and Learning Rooms.
A/V and Video Conference Standards for Teaching and Learning Rooms. Prepared by David Stormonth Division of Information Technology Phone 02 69334369 Mob 0439 644 946 E-mail [email protected] Overview
Understand VLANs, Wired LANs, and Wireless LANs
LESSON 1,2_B Understand VLANs, Wired LANs, and Wireless LANs Lesson Overview In this lesson, you will review: Wired local area networks Wireless local area networks Virtual local area networks (VLANs)
ZIPAMINI. Smart Home Controller. make your home smart. Control your home from anywhere in the world
ZIPAMINI Smart Home Controller Control your home from anywhere in the world find out more at www.zipato.com ZIPAMINI Connect everything Makes every home safe, comfortable and energy efficient MAKES EVERY
Inverter / Charger Installation General Operations and AC and DC Connections
Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope
Design Guide Universal Connectivity Grid SYSTIMAX Solutions from CommScope CONTENTS Introduction 3 Commercial building network overview 4 Zone cabling 5 Universal Connectivity Grid 6 UCG cell size 7 Integrating
Class 2 transformer (TBT) Low Tension Conform to EN 60742. A LED turns ON when the current exceeds 1 A at the 14V output connector
Technical notice TECHNICAL CHARACTERISTICS Power Class 2 transformer (TBT) Low Tension Conform to EN 60742 Rechargeable battery 16 Vac, 50-60Hz 50 Va min. 250 Va max 12 V, 7AH Protection A LED turns ON
QSE-CI-NWK-E Control Interface
QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices
