Commercial Roof Systems Selection Guide



Similar documents
C e r t a i n Te e d S e l e c t i o n G u i d e

Commercial Roof Systems

CHAPTER 7: Building Systems ROOFING SYSTEMS

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

Commercial Roof Systems

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

CREEK Technical Services, LLC

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

Please read the entire document before purchasing and installing any of these products

Peel & Seal Self-Stick Roofing Solutions

PRODUCT CONTROL SECTION

Roof Systems Overview

Mop it. Stick it. Spread it.

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

COMMERCIAL BUILDING APPLICATIONS

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

Building Owners Guide to a Duro-Last System!

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.

CertainTeed. Product Reference Guide

CertainTeed. Designer Shingles. Shown in Max Def Weathered Wood

ATLAS Roofing Products

tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association

Membrane Roofing. Advances in Membrane Roofing

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

MASTICS. 275 Centre St., Unit 15 Holbrook, MA (617) Shedd Rd. Middlefield, OH (440)

tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE

CertainTeed. Roofing Products. California OOL. Understanding Part 6 of Title 24, California Building Standards Code

Asphalt Shingle Application Requirements

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION

CertainTeed. Designer and Luxury Shingles. Shown in Landmark Weathered Wood

TARRANT COUNTY DETAIL STANDARDS

CertainTeed. Impact Resistant. Shingles. Shown in Landmark IR Weathered Wood. Est.1665

How to repair your existing low slope flat roof.

Proven roofing SyStemS

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

COMMERCIAL & LOW SLOPED ROOF SPECIALISTS TOTAL NDL SYSTEM MANUFACTURER WARRANTIES

CertainTeed. Designer and Luxury Shingles. Shown in Landmark Weathered Wood

CertainTeed. Designer and Luxury Shingles. Shown in Landmark Pro Max Def Weathered Wood

EPDM. Roofing systems

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

Low-slope reroofing guidelines

Self-Stick Roofing Solutions

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

FEATURING THE GOLD & PLATINUM COLLECTION

Table of Contents. To access data on JM Roofing Systems, visit our Web site at

Maintaining Your Roof

LAMA has developed over the years a wide range of products that can be used in the waterproofing

SBS-Modified Bitumen Roof Systems

Table of Contents. Benefits of UNIFLEX Fluid Applied Roofing Systems 2 3. Elastomeric Finish Coats 4 5. Aluminum Finish Coats 6

Durapax Coal Tar BUR Application Guide

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

Roofing Systems. New Applications / Re-Roofing / Maintenance

ROOF ASSEMBLIES CHAPTER 9

Table of Contents. Dedicated to Service and Support

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

3 BUILT-UP ROOFING THE RUBEROID BLUE BOOK

C e r t a i nte e d. D e s i g n e r S h i n g l e s. Shown in: Roof - Fieldstone; Siding - Cedar Impressions Double 7" Perfection Shingles Seagrass

NRCA s steep-slope manual is thoroughly revised for 2013

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

Colorado State University. Durrell Center Roof Repair

FIRESTONE BUILT-UP ROOFING SYSTEMS APPLICATION GUIDE 3/14/2011

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

ENERGY STAR Cool Roof Technology and Impact Resistance

CertainTeed. Designer Shingles. Shown in Max Def Weathered Wood

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

Roofing Material Specifications and Details

THERMOPLASTIC-POLYOLEFIN ROOFING (TPO) Data Center

Firestone SBS Modified Bitumen Roofing System Design and Application Guide

CertainTeed SOLAR. Solar From A Proven Source

ITEM THERMOPLASTIC MEMBRANE ROOFING

What makes DECRA Roofing Systems unique?

GENERAL REQUIREMENTS HENRY WARRANTED COMMERCIAL ROOFING SYSTEMS

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Prices Effective April 1, 2016

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

CHAPTER 6 ASPHALT ROLL ROOFING

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Design No. P736 September 26, Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)

Seamless Waterproofing. Systems

How To Compare Roofing Material

Transcription:

CertainTeed Commercial Roof Systems Selection Guide Good Better Best. Don't specify less. The chart below is a quick guide to choosing the right roof system for your needs. Please note: the best roofs have adequate drainage and utilize a double-layer of FlintBoard roof insulation. GOOD BETTER BEST Nailable Decks Non-Nailable Nailable Decks Non-Nailable Nailable Decks Non-Nailable APP Nailed base Mopped base Nailed base Mopped base Nailed base, 1 Mopped base, 1 and 1 APP cap and 1 APP cap and 1 premium and 1 premium smooth APP ply smooth APP ply APP cap APP cap and 1 APP cap and 1 APP cap SBS Nailed base Mopped base Nailed base, 1-2 Mopped base, Nailed base, Mopped base, and 1 SBS and 1 SBS BUR fiber glass 1-2 BUR 1 smooth SBS 1 smooth SBS premium cap premium cap interply sheets, fiber glass premium ply premium ply 1 SBS cap interply sheets, and 1 SBS and 1 SBS 1 SBS cap premium cap premium cap BUR Nailed base, 2 Mopped base, Nailed base, Mopped base, Nailed base, Mopped base, BUR interply 2 BUR interply 3 BUR interply 3 BUR interply 3 BUR interply 3 BUR interply sheets, gravel sheets, gravel sheets, gravel sheets, gravel sheets, sheets, surfacing or surfacing or surfacing or surfacing or 1 premium 1 premium fiber glass cap fiber glass cap fiber glass cap fiber glass cap BUR cap BUR cap SA SA NailBase SA PlyBase SA NailBase 2 SA Plybase SA NailBase SA PlyBase SA Cap SA Cap SA Plybase SA Cap SA Mid Ply SA Mid Ply SA Cap SA Cap SA Cap Get system specifications and CAD details @ www.certainteed.com/lowslopetechinfo or download CertaSpec, our specification writing tool @ www.certainteed.com/certaspec. ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: EXTERIOR: ROOFING SIDING WINDOWS FENCE RAILING TRIM DECKING FOUNDATIONS PIPE INTERIOR: INSULATION GYPSUM CEILINGS CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 Professional: 800-233-8990 Fax-on-Demand: 800-947-0057 www.certainteed.com COMM-080 2008 CertainTeed Corporation, Printed in U.S.A.

make the right choice the quality difference Experts in residential and commercial roofing CertainTeed is a leading manufacturer of commercial and residential roofing products and is a division of Saint-Gobain, the world s largest manufacturer of building materials. Saint-Gobain ranks among the world s top 100 industrial corporations, operating through a global network of more than 600 companies in more than 50 countries. A quality roof depends on two essential elements: excellent materials and superior workmanship. CertainTeed has been one of North America s leading roofing material manufacturers for over 100 years. Innovative solutions CertainTeed leads the way in smart, energy-saving products that help you meet new building standards. For instance, our CoolStar products with solar-reflective surfaces meet ENERGY STAR and initial California Title 24 requirements, and offer several installation advantages. Workmanship is key To help assure the best possible workmanship for your commercial roof installation, CertainTeed has established the Gold and Silver Star Contractor programs. These programs offer the building owner a selection of highly credentialed roofing contractors who have met the strictest criteria relating to financial credibility, workmanship history and sound business practices, including proper licenses and appropriate insurance. Outstanding warranty options Only CertainTeed Gold and Silver Star Contractors are eligible to apply for CertainTeed s NDL (No Dollar Limit) and Integrity Coverage (IC) warranties on specific roof projects. The three levels of IC warranties (see box below) are only available through CertainTeed Gold Star Contractors. Owners and specifiers who choose an IC option have the added security of manufacturer involvement in the maintenance and upkeep of each roofing system to maximize the life expectancy of the roof. Contact CertainTeed for complete warranty and maintenance plan details, including limitations and costs. Integrity Integrity Integrity Program NDL Assurance Maintenance Elements (GOOD) (BETTER) (BEST) Premium Details Premium System Specification 25-year NDL Warranty Inspections N/A Annual Semi-Annual Maintenance N/A N/A Semi-Annual Non-CertainTeed Roof Component Coverage N/A N/A Post-Storm Emergency Response N/A N/A Owner Requirements Proof of Proof of Notification Maintenance; Maintenance; of Alterations Notification of Notification of Alterations Alterations BUR (Built-Up Roofing) Traditional built-up roofing (BUR) derives its name from the building of a roof on-site using layers of base sheet, interply sheets and cap sheet or other surfacing such as gravel or liquid coating. Hot asphalt (bitumen) is the bonding and waterproofing agent between layers. BUR is suitable for most low slope roofing applications. The higher the quality of the BUR materials and asphalt used and the greater the number of plies (and separate asphalt moppings), the more superior the roof system. APP and SBS modified bitumen In the 1970s, technological advances in asphalt sciences led to the development of modifiers such as APP (atactic polypropylene) and SBS (styrenebutadiene-styrene) which, when added to unblown (unoxidized) asphalt, impart either plastic (APP) or rubber (SBS) characteristics. These additives provide enhanced performance characteristics to traditional asphalt. When coupled with reinforcements, such as polyester (superior elongation abilities) or fiber glass (high tensile strength), they create high-performance roof membranes. APP modified bitumen membranes are self-adhering when heated using a roofing torch. SBS modified bitumen membranes can be formulated for torch application, but are more commonly applied using hot asphalt or cold SBS modified bitumen adhesive. The result is a BUR system with significantly enhanced performance capabilities. Continuing improvements in technology have also resulted in self-adhering SBS roof membranes. When an SBS or APP cap sheet is combined with traditional BUR base sheets and interply sheets, the result is a hybrid roof offering the best of both systems, multiple plies and superior performance and longevity. Keep the following factors in mind when selecting or specifying a roof system: 1. Choose the highest possible quality materials from an established manufacturer with an excellent reputation for integrity. CertainTeed has been manufacturing roofing materials for over 100 years. 2. Compare similar products. Evaluate the technical data provided by the manufacturer. Compare the weights, thicknesses and ASTM test results. 3. Remember, the money saved today on a low cost roofing system can be more than offset by the need to reroof sooner as the result of poor performance leading to leakage or premature failure. 4. Consider the manufacturer s warranty. The length of the warranty term (in years) helps gauge the superiority of the system selected. Generally, the longer the warranty, the better the system. Is a guarantee which covers not only the material but also the contractor s workmanship available for the roof system selected? 5. Property value. Is the manufacturer s warranty transferable to a new building owner? 6. How committed is the roofing material manufacturer willing to be? Does the manufacturer, as an option to the owner, have an approved contractor program in place? If an enhanced warranty that includes workmanship is selected, will the manufacturer inspect the roof project? With CertainTeed, the answer to all of these questions is yes. 7. Consider energy costs. Keep in mind that white mineral surfaced cap sheets, light colored gravel surfacing or roofs coated with reflective roof coating will help reduce interior cooling costs. Consider a CertainTeed cap sheet with CoolStar reflective coating. 8. Choose a system manufacturer. CertainTeed provides the key elements of the roofing system insulation, adhesives and coatings, membranes and fasteners. 9. Consider building code requirements. Many local and state governments have specific guidelines for specifying roof systems.

www.certainteed.com BUR (Built-Up Roofing) Base Sheets Method* (Typical) per Roll per Roll Reference Glasbase Base Sheet Standard fiber glass base sheet MF, HA, CA 1.0mm 75 lbs. 300 sq. ft. D4601, Type II, (40mils) UL Type G2 Yosemite Buffer Heavy duty fiber glass base sheet; MF, HA 2.8mm 85 lbs. 100 sq. ft. D3909, D4897, Base Sheet ideal for recover applications (110mils) Type II, UL Type G3 Channel Vent Premium venting base sheet with MF, HA 3.0mm 78 lbs. 100 sq. ft. D4897, Type II, embossed channels for venting (120mils) UL Type G2 moisture; fiber glass mat Interply Sheets Flintglas Type IV Standard fiber glass ply sheet HA, CA 0.6mm 38 lbs. 500 sq. ft. D2178, Type IV, Ply Sheet (24mils) UL Type G1 Flintglas Type VI Heavier, premium fiber glass ply sheet HA, CA 0.8mm 48 lbs. 500 sq. ft. D2178, Type VI, Premium Ply Sheet (32mils) UL Type G1 No. 15 Perforated Felt Standard organic ply sheet HA 0.8mm 55 lbs. 400 sq. ft. D226, Type I, (32mils) UL Type 15 Cap Sheets Flintglas Mineral Fiber glass cap sheet for use over HA, CA 3.0mm 78 lbs. 100 sq. ft. D3909, Cap Sheet organic or fiber glass base and (120mils) UL Type G3 interply combinations Flintglas Cap Sheet Mineral surfaced fiber glass cap HA, CA 3.0mm 83 lbs. 100 sq. ft. D3909 with CoolStar sheet (120mils) *Application Methods: MF = Mechanically Fastened HA = Hot Asphalt CA = Cold Asphalt TA = Torch Applied SA = Self-Adhering APP Modified Bitumen Interply Sheets Method* (Typical) per Roll per Roll Reference Flintlastic STA Standard smooth surfaced polyester TA 4.0mm 87 lbs. 100 sq. ft. D6222, Grade S, APP; first ply in 2-ply systems or (160mils) Type I as cap with suitable coating Flintlastic STA Plus Premium, thicker, smooth surfaced TA 4.5mm 100 lbs. 100 sq. ft. D6222, Grade S, polyester APP; first ply in 2-ply (180mils) Type I systems or as cap with suitable coating Cap Sheets Flintlastic STA Premium, thicker, smooth surfaced TA 4.0mm 87 lbs. 100 sq. ft. D6222, Grade S, polyester APP; first ply in 2-ply (160mils) Type I systems or as cap with suitable coating Flintlastic STA Plus Premium, thicker, smooth surfaced TA 4.5mm 100 lbs. 100 sq. ft. D6222, Grade S, polyester APP; first ply in 2-ply (180mils) Type I systems or as cap with suitable coating Flintlastic GTA Standard polyester mineral surfaced TA 4.2mm 105 lbs. 100 sq. ft. D6222, Grade G, APP cap sheet (168mils) Type I Flintlastic GTA Standard polyester mineral surfaced APP TA 4.2mm 110 lbs. 100 sq. ft. D6222, Grade G, with CoolStar cap sheet (168mils) Type I Flintlastic GTA-FR Polyester mineral surfaced APP TA 4.2mm 105 lbs. 100 sq. ft. D6222, Grade G, cap sheet with fire retardant additives (168mils) Type I Flintlastic GTA-FR Polyester mineral surfaced APP TA 4.2mm 110 lbs. 100 sq. ft. D6222, Grade G, with CoolStar cap sheet with fire retardant additives (168mils) Type I and reflective CoolStar coating White Diamond GTA Polyester APP cap sheet TA 4.0mm 95 lbs. 100 sq. ft. D6222, Grade G, with fine particle surfacing (160mils) Type I Flintlastic White Polyester APP cap sheet with fine TA 4.0mm 100 lbs. 100 sq. ft. D6222, Grade G, Diamond GTA particle surfacing and reflective (160mils) Type I with CoolStar CoolStar coating APP Torch APP modified roofing membrane TA 3.4mm 82 lbs. 100 sq. ft. (135mils)

www.certainteed.com SBS Modified Bitumen Base and Interply Sheets Method* (Typical) per Roll per Roll Reference Flexiglas Base Sheet SBS modified, fiber glass base sheet HA, CA, MF 1.2mm 90 lbs. 300 sq. ft. D4601, Type II (48mils) Flexiglas FR Premium fire resistant, SBS modified HA, CA, MF 2.3mm 90 lbs. 150 sq. ft. D4601, Type II, Base Sheet fiber glass base sheet (92mils) D6163, Grade S, Type I Flintlastic FR Premium fire resistant, SBS modified TA, MF 3.0mm 81 lbs. 100 sq. ft. D4601, Type II, Base T Sheet bitumen, coated fiber glass base sheet (120mils) D6163, Grade S, Type I Poly SMS Base Sheet SBS modified, polyester base sheet; HA, CA, MF 2.0mm 90 lbs. 200 sq. ft. D4601, Type II (80mils) Ultra Poly SMS Premium heavyweight SBS modified, HA, CA, MF 3.7mm 90 lbs. 100 sq. ft. D6164, Grade S, Base Sheet polyester base sheet (148mils) Type I Black Diamond Self-adhering, SBS modified, fiber glass SA 1.5mm 78 lbs. 200 sq. ft. D1970 Base Sheet base sheet (for noncombustible decks) (60mils) with fine particle surfacing All Weather/Empire Heavyweight, SBS modified, fiber glass MF, HA, CA 1.8mm 70 lbs. 200 sq. ft. D4601, Type II Base Sheet base sheet, use as tile underlayment (70mils) *Application Methods: MF = Mechanically Fastened HA = Hot Asphalt CA = Cold Asphalt TA = Torch Applied SA = Self-Adhering SBS Modified Bitumen Cap Sheets Method* (Typical) per Roll per Roll Reference Flexiglas Premium Heavy duty SBS modified, fiber glass HA, CA 4.0mm 100 lbs. 100 sq. ft. D6163, Grade G, Cap Sheet 960 mineral surfaced cap sheet (160mils) Type I Flexiglas Premium Cap Heavy duty SBS modified, fiber glass HA, CA 4.0mm 105 lbs. 100 sq. ft. D6163, Grade G, Sheet 960 with CoolStar (160mils) Type I Flintlastic FR Mineral surfaced, fire-resistant, SBS HA, CA 3.5mm 90 lbs. 100 sq. ft. D6163, Grade G, Cap Sheet modified bitumen, fiber glass cap sheet (140mils) Type I Flintlastic FR Cap Mineral surfaced, fire resistant, SBS HA, CA 3.5mm 95 lbs. 100 sq. ft. D6163, Grade G, Sheet with CoolStar modified bitumen, fiber glass cap sheet (140mils) Type I Flintlastic FR Cap T Mineral surfaced, fire-resistant, SBS TA 4.0mm 100 lbs. 100 sq. ft. D6163, Grade G, modified bitumen, fiber glass cap sheet (140mils) Type I Flintlastic FR Cap T Mineral surfaced, fire-resistant, SBS TA 4.0mm 105 lbs. 100 sq. ft. D6163, Grade G, with CoolStar modified bitumen, fiber glass cap sheet (160mils) Type I Flintlastic FR-P Fire-resistant, SBS modified, polyester, HA, CA 4.2mm 105 lbs. 100 sq. ft. D6164, Grade G, mineral surfaced cap sheet (168mils) Type I Flintlastic FR-P Fire-resistant, SBS modified, polyester, HA, CA 4.2mm 110 lbs. 100 sq. ft. D6164, Grade G, with CoolStar mineral surfaced cap sheet with (168mils) Type I reflective CoolStar coating Flintlastic Premium, fire-resistant, SBS modified, HA, CA 4.2mm 105 lbs. 100 sq. ft. D6164, Grade G, Premium FR-P heavyweight polyester mineral (168mils) Type II surfaced cap sheet Flintlastic Premium, fire-resistant, SBS modified, HA, CA 4.2mm 110 lbs. 100 sq. ft. D6164, Grade G, Premium FR-P heavyweight polyester mineral surfaced (168mils) Type II with CoolStar cap sheet with reflective CoolStar Flintlastic GMS Mineral surfaced, SBS modified, HA, CA 4.0mm 97 lbs. 100 sq. ft. D6164, Grade G, polyester cap sheet (160mils) Type I Flintlastic GMS Mineral surfaced, SBS modified, HA, CA 4.0mm 102 lbs. 100 sq. ft. D6164, Grade G, with CoolStar polyester cap sheet with (160mils) Type I reflective CoolStar coating Flintlastic Premium, SBS modified, heavyweight HA, CA 4.2mm 105 lbs. 100 sq. ft. D6164, Grade G, Premium GMS polyester mineral surfaced cap sheet (168mils) Type II Flintlastic Premium Premium, SBS modified, heavyweight HA, CA 4.2mm 110 lbs. 100 sq. ft. D6164, Grade G, GMS with CoolStar polyester mineral surfaced cap sheet (168mils) Type II Flintlastic GTS SBS modified, heavyweight polyester TA 4.5mm 90 lbs. 75 sq. ft. D6164, Grade G, mineral surfaced cap sheet (180mils) Type II Flintlastic GTS Premium, SBS modified, heavyweight TA 4.5mm 94 lbs. 75 sq. ft. D6164, Grade G, with CoolStar polyester mineral surfaced cap sheet (180mils) Type II FlintClad Premium, SBS modified, polyester TA 4.0mm 95 lbs. 100 sq. ft. D6298 cap sheet with foil facing (160mils)

innovative products www.certainteed.com Self-Adhering SBS Modified Bitumen Self-Adhering SBS Modified Bitumen Roofing System CertainTeed Flintlastic SA is a premium, self-adhering SBS modified bitumen roofing system comprising a nailable base or self-adhering ply base with a top surface designed to accept self-adhering membrane, a self-adhering mid ply and a self-adhering cap sheet. The Flintlastic SA product line is manufactured with premium quality materials, and the roof system specifications have been engineered to provide roofs that offer excellent longevity and performance. The complete Flintlastic SA roofing system offers a number of advantages: Ease of application No hot asphalt or torches needed for installation Minimal equipment requirements Cleaner work environment In addition, Flintlastic SA Cap Sheet is available in a variety of colors that complement the most popular CertainTeed shingle colors, for use on carports, porches and other residential low slope applications. Flintlastic SA products can be used in various system configurations, depending on the roof requirements. For small projects, such as decks, additions and porches, two-ply systems with Flintlastic SA NailBase or Flintlastic SA PlyBase, and Flintlastic SA Cap Sheet may be appropriate (in conjunction with FlintFlash SA flashing membrane, as specified by CertainTeed). For larger roofs and commercial applications, three-ply systems consisting of Flintlastic SA NailBase or Flintlastic SA PlyBase covered with Flintlastic SA Mid Ply and Flintlastic SA Cap Sheet are recommended. Roofs and decks must have proper drainage. Refer to the CertainTeed Commercial Roof Systems Manual for product data sheets and complete specification details. Product application must comply with CertainTeed installation instructions. Cool Roof Solutions from CertainTeed As new building standards are introduced, CertainTeed is proud to be at the forefront of technology. CertainTeed s CoolStar surfaced products are rated by the Cool Roof Rating Council (CRRC), are initial California Title 24 compliant and meet ENERGY STAR requirements. CoolStar Characteristics Durable, flexible, acrylic-based coating, highly reflective, brilliant white color. Saves energy, time and money Factory-applied reflective coating, hassle-free installation once you cap it, it s finished. Excels in performance and durability High-quality roof with all the advantages of a redundant system (including UL Class A fire resistance), easily repaired and maintained. Method (Typical) per Roll per Roll Reference Flintlastic SA SBS modified, fiber glass base sheet MF, HA 1.5mm 84 lbs. 200 sq. ft. D4601, Type II NailBase (not self-adhering) with a unique (60mils) permanent top surface film Flintlastic SA Self-adhering, SBS modified, SA 1.5mm 88 lbs. 200 sq. ft. D4601, Type II, PlyBase fiber glass base sheet with a unique (60mils) D1970 permanent top surface film Flintlastic SA Self-adhering, SBS modified, SA 3.0mm 68 lbs. 100 sq. ft. D6164, Grade S, Mid Ply polyester/fiber glass scrim (120mils) Type I combination mat reinforced, base sheet with a unique permanent top surface film Flintlastic SA Cap Self-adhering, SBS modified, SA 4.0mm 97 lbs. 100 sq. ft. D6164, Grade G, polyester/fiber glass scrim combination (160mils) Type I mat reinforced, cap sheet with mineral surfaced cap sheet Flintlastic SA Cap Self-adhering SBS modified, SA 4.0mm 102 lbs. 100 sq. ft. D6164 with CoolStar polyester/fiber glass scrim combination (160mils) mat reinforced, cap sheet with reflective CoolStar coating Flintlastic SA Cap FR Self-adhering, fire-resistant, SA 4.0mm 97 lbs. 100 sq. ft. D6164, Grade G, SBS modified, polyester/fiber glass (160mils) Type I scrim combination mat reinforced, mineral surfaced cap sheet Flintlastic SA FR Cap Self-adhering, fire-resistant, SA 4.0mm 102 lbs. 100 sq. ft. D6164, Grade G, with CoolStar SBS modified, polyester/fiber glass (160mils) Type I, UL 2218, scrim combination mat reinforced, Class 4, IR mineral surfaced cap sheet with reflective CoolStar coating FlintFlash SA Self-adhering SBS modified bitumen, SA 3.0mm 17 lbs. 25 or 50 D6164, Grade S, pre-cut flashing (120mils) sq. ft. Type I *Application Methods: MF = Mechanically Fastened HA = Hot Asphalt CA = Cold Asphalt TA = Torch Applied SA = Self-Adhering

www.certainteed.com Roofing Insulation FlintBoard ISO Features a closed-cell polyiso core laminated to heavy, black (non-asphaltic), ASTM C1289-95, Type II fiber-reinforced felt facers FlintBoard ISO-T Features a tapered design to promote positive drainage ASTM C1289-95, Type II FlintBoard ISO Plus Composite roof insulation, with foam core laminated to 1/2" perlite ASTM C1289-95, Type II or Type III with a fiber-reinforced felt facer FlintBoard ISO-T Plus Composite roof insulation with a tapered design to promote positive drainage ASTM C1289-95, Type II or Type III FlintBoard ISO Cold Featuring a heavy duty facer designed specifically for single ply, COLD applied hybrid ASTM C1289-95, Type II BUR and SBS modified bitumen roof systems FlintBoard CV Cross-ventilating design specifically for use over sloped unventilated roof decks ASTM C1289-95, Type V FlintBoard Pre-packaged in triangular sections only (not the entire cricket), each with a right angle ASTM C1289-95, Type II Pre-Cut Crickets to align with CertainTeed s standard 4' x 4' tapered FlintBoard insulation panels Fasteners PRODUCT NAME FlintFast #12 FlintFast #14 DESCRIPTION Features sharp drill point and tapered wedge entry; corrosion protection and back-out resistance; available in lengths from 1-5/8" to 8" Heavy duty drill point fasteners with tapered wedge entry; low-profile head, deep threads; available in lengths from 1-1/2" to 12" 3" Galvalume Metal Concave, reinforced circular design with low profile; designed for outer perimeter strength with recess for screw head Insulation Plates Primers FlintPrime A general purpose, penetration asphalt primer used for the preparation of all types of Meets or exceeds ASTM D41, surfaces prior to application of hot or cold asphalt coatings. Fed. Spec. SA-A-701, AASHTO M-116, Miami-Dade Approved FlintPrime LV A superior prime coat, formulated with low-voc penetrating solvents that promote the Meets or exceeds ASTM D41, adhesion of roofing materials to the roof surface. An ideal base coat before applying Fed. Spec. SA-A-701, AASHTO asphalt peel-and-stick membranes. Seals masonry, roofing surfaces and metal. M-116, Miami-Dade Approved FlintPrime SA Adhesives A water-based polymer modified primer for use with self-adhering modified bitumen roofing membrane systems such as Flintlastic SA. Designed to enhance adhesion of self-adhering modified bitumen membranes. FlintBond A cold applied, high strength SBS polymer modified asphalt adhesive that provides Meets or exceeds ASTM D3019 excellent adhesion and elongation properties. Available in brush grade, trowel grade, Type III, U.L. Listed, File #R11656, and caulk grade. Asbestos-free. Control #63P6, Miami-Dade Approved Coatings FlintCoat -A PLUS Single-component, SBS rubber modified asphalt, specially formulated with aluminum U.L. Listed, File #R11656, pigment to be used as a reflective elastomeric coating with modified bitumen membranes, Control #63P6, BUR and primed metal surfaces. ENERGY STAR FlintCoat -A 300 Made of selected asphalts and pigment flakes of pure aluminum, blended with mineral Meets or exceeds ASTM D2824, fibers and refined solvents for heavy duty performance capability. Aluminum flakes form Type II, ASTM D3805, a reflective metallic shield over the base material to create a self-protecting roof coating ASTM D962 Type II, with long-lasting moisture- and heat-resistant properties. U.L. Class A Listed, File #R11656, Control #63P6, ENERGY STAR FlintCoat -A 150 Made of selected asphalts and pigment flakes of pure aluminum, blended with mineral U.L. Class A Listed, File #R11656, fibers and refined solvents for heavy duty performance capability. Aluminum flakes form Control #63P6; a reflective metallic shield over the base material to create a self-protecting roof Miami-Dade Approved coating with long-lasting moisture- and heat-resistant properties. FlintCoat -A NF Non-fibered aluminum roof coating formulation of selected asphalts, refined solvents and UL Class A Listed, fine aluminum flakes that form a reflective metallic shield over the base material, creating File #R11656, Control #63P6, a self-protecting roof coating with long-lasting moisture- and heat-resistant properties. Miami-Dade Approved FlintCoat -W A copolymer elastomeric emulsion exterior protective coating that provides excellent U.L. Listed, File #R11656, protection, appearance, mildew resistance, color stability, weatherability and flexibility. Control #63P6, ENERGY STAR FlintCoat -E Emulsion roof coating made with refined asphalt, bentonite clay, emulsifiers and fibers Meets or exceeds ASTM D1227 for brush or spray application on smooth surface and metal roofs. Withstands variations Type II, Class I, ASTM D1187 in temperature and weather, and resists the absorption of exterior moisture. Type I and II, U.L. Listed, No odor or fumes. File #R11656, Control #63P6, FM Approved, Miami-Dade Approved Repair FlintPatch Asbestos-free wet/dry rubberized flashing cement, compounded with a blend of Meets or exceeds ASTM D4586 rubber-reinforced asphalt, mineral fibers and refined solvents in a heavy, pliable Type I and ASTM D3409, Fed, consistency for ease of application by trowel. Spec C-153 Type 1 (Asbestos Free), Miami-Dade Approved