www.nilsen.com.au SWITCHBOARDS



Similar documents
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Switch onto Mayfield. Mayfield Capability Profile. Design, manufacturing, installation and commissioning of switchroom and switchboard solutions.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

FAQs-Main switchboard design criteria

SAFETY ALERT SWITCHBOARD INTERNAL SEGREGATION AND IP RATING. May 2014 BACKGROUND

Unified requirements for systems with voltages above 1 kv up to 15 kv

The Intelligent AX1 Switchgear for Medium Voltage

Low Voltage Switchgear MNS is with MSpeed

Changing industry standards: friend or foe?

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

MNS is Switchgear System Technical Overview

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Providing Consulting Engineers and Switchboard Builders the BUILDING BLOCKS for advanced & cost effective solutions TECHNO MODULAR SWITCHBOARD SYSTEM

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

Fusible Disconnect Switch

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Power products and systems. Intelligent solutions for power distribution Zone concept

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

POWERING MINING AND CONSTRUCTION. Company overview.

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

P System Cubicles. Certified for more safety

Quality. Reliability. Flexibility. Safety. Corporate Profile. RPS Switchgear the world s. premier manufacturer and. supplier of high voltage

JLT Mining. Utilising our expert knowledge of the mining industry and through understanding your individual business, JLT Mining can deliver:

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

safe and reliable engine starting

Choosing for tranquility

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

Low Voltage Switchboards The Best Technical Solution for Your Ship

Nothing s BetterThan the Original MODAN Power Distribution Systems

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Which switchboards equip your building facilities for the future?

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Food Industry/Cold Storage NEXT GENERATION DESIGN & CONSTRUCT

Electrical Distribution Services for Mining and Metals Industries

Sample - No Commercial Use

Secondary Unit Substations

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Electrical Grounding. Appendix C

Comparative study for cables and busbars

MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

TIA-942 Data Centre Standards Overview WHITE PAPER

Choosing the Best Solution for Reducing Arc Energy

Power-Zone 4 Arc Resistant Low Voltage Switchgear

SIVACON The Versatile Low-Voltage Switchboard

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

SIVACON Low Voltage Switchboard

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Session Four: Internal Arc Safety in New and Existing Switchgear

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

POWER FACTOR CORRECTION

IR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. ex.com. ID 4016 Rev A

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011

Andre Gretler, LPLS BU Function Operation and Sales Low Voltage Systems ANSI vs IEC. BU 3101 Low Voltage Systems June 27, 2013 Slide 1

EXPRESSION OF INTEREST

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

CAPABILITY STATEMENT MCLEOD TRAINING ORGANISATION PTY LTD

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Hitech Electrical Automation Pty Ltd. Company Profile & Capability Statement

Electrical Equipment in Hazardous Areas: Field Inspections

Increasing safety, reliability and efficiency for today s data centers

Electrical Shore Connections / Cold Ironing

IEC & 2 standard. The reference for safe and reliable LV switchboards

How To Get A Power Line Extension

This section applies to the design and installation of transformers.

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

New standardized approach to arc flash protection

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

Addendum #2 Contract UK-11-13

FIRE DETECTION AND ALARM SYSTEMS

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

Arc Terminator Active Arc-Resistant Switchgear

JUA Underwriting Agency Pty Ltd

Cable/Conduit Conversion

technology UICK progressive sustainable any design, any shape, any colour, anywhere you like!

Mitigation of Arc-Flash Hazards and Reduction of Costs by Selective Arc-Flash Protection

Securing your electrical installations Prisma,

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Medium voltage arc flash eliminator units VAM 3ED,

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

SENTRON Switching and Protection Devices Air Circuit Breakers

INNER RANGE TRAINING CENTRE

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

HSEQ MANAGEMENT MANUAL

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

know-how Giant in distributing electricity for industry Prisma GK

Transcription:

www.nilsen.com.au SWITCHBOARDS

THE NILSEN TEAM Founded in 1916, Nilsen has an unbroken record of excellence in electrical and communications engineering, contracting and maintenance services. A responsible corporate citizen, Nilsen maintains a strong ethical code in its relations with customers, personnel and suppliers. The rewards have come by way of major infrastructure, commercial, industrial, defence and other government projects and in the recognition received year after year by Australia s leading industry association, NECA.

COMMUNICATING WITH CLIENTS Fulfi lling requirements We work with you to achieve the best technical and commercial outcome for your project. Our team of experts have covered the most demanding applications in stressful and hostile environments including operation in high dust and high temperature environments, on wash-down and high moisture level sites or in service areas such as marine and offshore platform locations. Our experience in challenging applications is your guarantee that we will meet your needs. Attention to detail makes for the Nilsen difference a difference that has seen us win awards for our products. Nilsen: Experts in Power Distribution and Motor Control Centres

PROVEN DESIGNS Our Certifi cation is your Assurance Nilsen switchboards and motor control centres have been extensively type-tested to relevant Australian and international standards, up to 100kA at 5000amps including arc fault containment and temperature rise testing. The Nilsen designs recognise priorities such as safety in accessing components, segregation and service considerations. The range of Nilsen-registered, type-tested designs gives you the assurance that we are able not only to provide you with the ideal design for your application but also with verifi cation of meeting the necessary standards. This is one of the many critical differences that make Nilsen your switchboard and motor control centre partner. OUR EXPERIENCE You name it we have done it We provide our switchboards and motor control centres to a broad market including: Telephone Exchanges Defence Water treatment and storage Municipal projects Mining, benefi ciation, and smelting Stacker/reclaimers Shipping terminals Refrigeration plants Abattoirs and food processing Cranes Heavy industry Automotive industries Commercial developments Shopping centres Apartment complexes Data Centres Roads and tunnels Electricity generation Hospitals

THE HUMAN ELEMENT Highly qualifi ed and highly trained Nilsen people are among the most highly qualifi ed and trained in the industry. Training in our companies is embedded in the most fundamental way. It is our personnel that is our competitive advantage and we are generous in the allocation of resources to achieve effective training in areas such as safety. project management, as well as technology developments and negotiation skills. We are award winners in Health, Safety and Environment, and continuously drill our operative personnel in both procedures and behaviour. It is all part of the professional approach that infi ltrates everything we do. RIGHT FOR THE JOB All aspects are considered Nilsen provides switchboards, motor control centres and control panels complying with specifi c customer requirements and using its N-series board building concepts, can engineer customised packages meeting demanding type testing and segregation requirements. 415 V, 690 V, 3.3 kv, 6.6 kv, 11 kv and 24 kv switchboards Type testing to AS3439 and AS2086 including arc fault containment Annex AA Arc proofi ng in accordance with IEC 60298 app. AA Earthquake tested to AS 1170.4 Cat 1, 2 and 3 Fully demountable starters and feeders to AS 3439.1 (Forms 1 to 4) Segregation to form 4B Safe access including Class A (criteria 1 to 5) Single sided, back connected, and back to back options Generous busbar zones, sleeved or unsleeved busbars Fixed, demountable and withdrawable switchboards and motor control Transportable switchroom packages Nothing escapes our attention

DESIGN CONSIDERATIONS Type testing to 100 ka Nilsen switchboards are designed for maximum fault levels to 100kA for bolted faults. The busbar structures are designed to carry the forces of sustained faults as well as the associated temperature rise limitations. Arc fault containment The incorporation of metal-clad switchgear places more emphasis on arc fault containment. Nilsen has particular expertise in this area so critical to safe operation of switchboards. Internal arcing fault containment is specifi ed in an appendix to AS3439.1. and Nilsen s very rigorous testing of its designs to this specifi cation, for limited and unlimited arc fault containment is your assurance of performance. Busbar selection Nilsen applies additional derating factors to the derating tables of AS3000. Although adding to copper cost, the payback in terms of energy savings through reduced losses in the board can be as short as half a year or even shorter. Busbar jointing Temperature rise depends on the rate of heat dissipation from busbar joints. The effect of oxidation on contact resistance can also derate a switchboard. Nilsen carries out a series of tests on its switchboards using four-terminal low ohm measurements to assure you of reliable long-term operation of the busbar joints.

Safe access Nilsen design for the safe access and intelligent layout requirements including easy front and rear cable access to cells, generous cable ways along the entire board length, multiple cable gland plate entry positions as well as allowing for unfettered access for future extensions. Environmental Because of the broad range of applications, we are experts in tailoring our switchboards and motor control centres to tough environmental conditions. This can involve special engineering for access, ventilation, chimneys, fan placement and the study of natural convection paths. Many applications also involve outdoor use, particularly in remote mine site locations. Motor control centres Nilsen motor control centres incorporate a highly cost-effective manufacturing strategy, providing high component density, yet safe clearance distances to safeguard against tracking, and reduced operating temperature. Nilsen expertise in control options includes not only PLCs but also industrial bus architecture and hierarchical control schemes with human interface panels. PROTECTION OF YOUR ASSETS Nilsen maintenance provides maximum return Switchgear and busbar are the most important areas for regular inspection and maintenance. Inspection for heat sources can reveal faulty busbar joints, cable terminations, etc. We perform joint resistance tests also for circuit breaker contacts. In addition arc chute inspections are carried out, and protection relays examined. This latter area (coordination or grading) is important to you because without these types of test, the shift in relay characteristics can cause a downstream fault to shut off large sections of upstream equipment. Our clients speak for us Nilsen switchboards and motor control centres are part of the electrical plant of the largest Australian companies and government organisations. From the National Parliament to submarine service, we are represented and known for the high standards we adhere to. You too can rely on us for solid performance!

Nilsen (SA) Pty. Ltd. 100 Regency Road, Ferryden Park, SA 5010 Phone:+61 (08) 8440 5300 Fax:+61 (08) 8347 0347 Email: nilsensa@nilsen.com.au 5 Pyne Close, Mt Gambier SA 5290 Phone:+61 (08) 8725 2442 Fax:+61 (08) 8725 2327 Email: gambier@nilsen.com.au Nilsen (VIC) Pty. Ltd. 43 Sheehan Road, Heidelberg West, VIC 3081 Phone:+61 (03) 9450 1300 Fax:+61 (03) 9457 5261 Email: nilsvic@nilsen.com.au Lic. No. REC 6 71 Princes Drive, Morwell, VIC 3840 Phone:+61 (03) 5136 9500 Fax:+61 (03) 5134 4631 Email: nilsmwl@nilsen.com.au Nilsen (WA) Pty. Ltd. 12 Effi ciency Way, Bibra Lake, WA 6163 Phone:+61 (08) 9434 2311 Fax:+61 (08) 9434 2322 Email: nilsenwa@nilsen.com.au Lic. No. EC000982 5/1 Halifax Drive, Bunbury, WA 6230 Phone:+61 (08) 9726 0800 Fax:+61 (08) 9726 0866 Email: nilsenby@nilsen.com.au Nilsen Resources Pty. Ltd. 4 Park Place, Bibra Lake, WA 6163 Phone: +61 (08) 9434 6773 Phone: +61 (08) 9434 9083 Nilsen (NSW) Pty. Ltd. Unit 26/38 South Street, Rydalmere, NSW 2116 Phone:+61 (02) 9898 9355 Fax:+61 (02) 9638 0343 Email: nilsensw@nilsen.com.au Lic. No. 186489C Nilsen (QLD) Pty. Ltd. 379 Thynne Road, Morningside, QLD 4170 Phone:+61 (07) 3899 8866 Fax:+61 (07) 3899 8766 Email: nilsenq@nilsen.com.au Lic. No. 66226 Unit 4/12 Bassett Street, Gladstone, QLD 4680 Phone:+61 (07) 4972 5207 Fax:+61 (07) 4972 5294 Email: Gladstone@nilsen.com.au Cairns PO BOX 1112, Cairns QLD 4870 Phone: +61 (07) 4034 9255 Fax: +61 (07) 4034 9155 Email: cairns@nilsen.com.au Mackay PO BOX 5034, QLD 4741 Phone:+61 (07) 4944 0068 Fax:+61 (07) 4944 0131 Email: mackay@nilsen.com.au Townsville PO BOX 7191, QLD 4814 Phone:+61 (07) 4775 4326 Fax:+61 (07) 4779 0957 Email: townsville@nilsen.com.au Nilsen (NT) Pty. Ltd. 41 Berrimah Road Berrimah NT 0828 Phone:+61 (08) 8947 1134 Fax:+61 (08) 8947 3173 Email: nedarwin@nilsen.com.au Nilsen Networks Pty. Ltd. Unit 4/3-5 Gilda Court, Mulgrave, VIC 3170 Phone: 1300 734 766 Fax: 1300 735 466 Oliver J Nilsen (Australia) Ltd 37 Sheehan Road, Heidelberg West, VIC 3081 Phone: +61 (03) 9457 5566 Fax: +61 (03) 9459 5966 www.nilsen.com.au