Extend the Life of Existing Switchgear



Similar documents
Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Electrical Distribution Services for Mining and Metals Industries

Houston Service Center Medium Voltage Service and Aftermarket Solutions

Electrical Distribution Services from Schneider Electric

The following components are common to most cubicles; this example is an ABB HK cubicle.

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Risk Mitigation of Aging Electrical Infrastructure

Switchgear and Metal-Enclosed Bus

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Defining the Needs of Modern Data Center Power Systems, Low Voltage Circuit Breaker Application

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Primary and Secondary Electrical Distribution Systems

Choosing the Best Solution for Reducing Arc Energy

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Application of Four-Pole Circuit Breakers within Data Centers

Sample - No Commercial Use

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Reliability requires consulting engineers and end users to grasp design, maintenance basics. By Reza Tajali, P.E. Square D Power Systems Engineering

What will MV switchgear look like in the future? by Jean-Marc Biasse

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Bypass transfer switch mechanisms

Secondary Unit Substations

Alternate Methods to Short Circuit Breaker Coordination

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Evaluating Water-Damaged Electrical Equipment

Contents. Description. Product Selection Guide

Advantages of Fixed Circuit Breaker Switchgear

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Evaluating Water-Damaged Electrical Equipment

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

Evaluating Water-Damaged Electrical Equipment

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Evaluating Fire- and Heat-Damaged Electrical Equipment

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

GUIDELINES FOR WATER-DAMAGED ELECTRICAL EQUIPMENT

Atlanta Chapter IEEE Industry Applications Society

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Low Voltage Switchgear

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Addendum #2 Contract UK-11-13

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

How to reduce exposure to arc flash hazards

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Andre Gretler, LPLS BU Function Operation and Sales Low Voltage Systems ANSI vs IEC. BU 3101 Low Voltage Systems June 27, 2013 Slide 1

Arc Terminator Active Arc-Resistant Switchgear

Part 1 System Modeling & Studies for Existing Systems

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

SENTRON Switching and Protection Devices Air Circuit Breakers

Increasing safety, reliability and efficiency for today s data centers

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Engineers Edge, LLC PDH & Professional Training

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

ICM Project Station Infrastructure and Equipment

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

The Intelligent AX1 Switchgear for Medium Voltage

Mission Critical Data Center Systems

How To Choose A Transformer

Life cycle services for protection and control relays Full support from start to finish

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

Medium Voltage Electrical Distribution

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

SECTION SWITCHBOARDS

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

A USERS GUIDE TO ARC RESISTANT LOW VOLTAGE SWITCHGEAR & MOTOR CONTROL ANALYTICAL COMPARISON VS ARC FLASH TEST RESULTS

SIEMENS Transmission and Distribution

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Engineering Series Ratings: Is It Practical?

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

MCC Ratings. Voltage Rating

The Application of Circuit Breakers to Reduce Downtime in Datacentres

Catalog. Arc Guard System TM TVOC-2

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Application Guide. MNS-SG Low Voltage, Metal-Enclosed, Drawout Switchgear

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Electrical Shore Connections / Cold Ironing

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

Arc Flash Energy Mitigation Techniques

Safety By Design. Strategies for Electrical Contractors

Earth Fault Detection Basics in Theory

Transcription:

Extend the Life of Existing Switchgear January 2011/1910DB1002 by Hal Theobald, Product Manager Schneider Electric USA, Inc. Make the most of your energy SM

Summary Introduction... p 3 Maintenance Requirements... p 4 Replace or (Continue to) Repair?... p 4 Modernize and Upgrade LV and MV Switchgear... p 5 Direct Replacement and Retrofill Solutions... p 6 Choosing the Right Switchgear Solution... p 6 Why Upgrade?... p 7 Conclusion... p 8 Appendix: Circuit Breaker Terminology... p 8

Introduction In an industrial facility, nothing operates without a reliable flow of electricity. Therefore, it is critical to properly maintain the switchgear and switchboards that distribute electricity through the power system. Switchboards are more commonly used in commercial and light industrial applications, while switchgear is usually specified in heavy industrial applications, where the demands on the equipment require more robust construction. Electrical switchgear has two types of components that make up the system, which can be referred to as passive and active. The passive components include such things as the steel framing channels, cover plates, barriers, horizontal and vertical bus structures, as well as components that make up the mechanical structure of the equipment. The critical active components are the power circuit breakers or fused devices that comprise the overcurrent protective system. White paper for switchgear modernization options 3

Maintenance Requirements Replace or (Continue to) Repair? Major electrical equipment manufacturers generally require annual maintenance for power circuit breakers to ensure proper operation and maintain equipment warranties. This maintenance consists of cleaning and lubrication of the primary and secondary disconnects, racking mechanisms, and cell interlocks. A thorough onsite maintenance workscope for lowvoltage power circuit breakers includes: Inspection Cleaning and lubrication Adjustments Overcurrent protective device testing Insulation testing Charge/close/trip circuit testing The use of new or refurbished parts or subassemblies may be required to return a circuit breaker to good operating condition. A more intensive maintenance option for circuit breakers is in-shop reconditioning. With this option, the breaker is initially tested against ANSI standards and then completely disassembled, cleaned and inspected. Damaged parts are refurbished or replaced, and pivot points are relubricated before the circuit breaker is reassembled. The reconditioned breaker is retested against ANSI standards, including primary injection or timing testing. When considering whether to maintain equipment or replace it, facility managers must take into account the initial capital cost, along with potential disruption to the facility s processes and workflow during the course of changing out the equipment. Unless process loads can be rerouted temporarily during the demolition of old equipment and installation of the new switchgear, the cost of lost production can be substantial. Another consideration that is often overlooked is conduit placement. Installing new switchgear (which is usually smaller than the older/obsolete equipment it is designed to replace) requires that existing conduit above and below the equipment be moved. Cabling may need to be replaced or spliced, as well. This is an expensive and time-consuming process, often costing more in labor and material than the cost of the new equipment. Facility managers now have another option to consider for the repair vs. replace dilemma. New design capabilities exist to modernize and extend the life of the active components, i.e., circuit breakers, while leaving the existing switchgear structure intact. Even with annual maintenance, however, power circuit breakers may need additional upkeep or upgrades. Factors to consider include the operating environment, availability of spare parts, reliability and the cost of ongoing maintenance. There may also be the need to increase the switchgear s fault or continuous current rating, or the desire to upgrade technology. As a result, facility managers are often faced with the choice of maintaining aging (or obsolete) equipment or replacing it with a new switchgear line-up to take advantage of current technology. 4 White paper for switchgear modernization options

Modernize and Upgrade LV and MV Switchgear Modern power circuit breakers are designed using space-age materials in very compact formats, with digital trip units. They also offer very high fault current withstand capability without the use of limiter fuses. Since power circuit breakers provide such a vital function in protecting the electrical system, as well as reducing the risk to electrical workers from arcing faults, these design improvements are a quantum leap forward in equipment and personnel protection. In addition, they have lower maintenance requirements than the older, open iron frame circuit breaker designs. Retrofitting is a general term that is used to define any process which allows for modernization and life extension of electrical equipment. Several different retrofit strategies exist for adapting modern circuit breakers into existing low-voltage and mediumvoltage switchgear structures. The switchgear structure, conduits, cabling and footprint are left intact, which saves time and money (above). Aging or obsolete circuit breakers (left) are replaced with state-of-the-art circuit breakers, which brings the existing line-up to current technology (right). White paper for switchgear modernization options 5

Direct Replacement and Retrofill Solutions Choosing the Right Switchgear Solution Direct replacement circuit breakers and circuit breaker retrofill solutions fall under the general category definition of retrofits. Though different processes, both have the same end result: improved power system reliability and lower life-cycle costs. Direct replacement: A new circuit breaker designed to fit into the existing cubicle with little-to-no modification to the switchgear cell. A low-voltage direct replacement breaker uses a standard circuit breaker that is interchangeable with new and old switchgear of various manufacturers. This is accomplished via the use of an adapter cradle to fit the new circuit breaker into the existing switchgear. A medium-voltage replacement circuit breaker is designed to fit directly into the existing OEM switchgear. An adapter cradle is not utilized. The direct replacement solutions reduce downtime since there is minimal (if any) outage on the equipment bus. Retrofill: The existing switchgear cell and bus are modified to accept the new circuit breaker. This process usually requires a longer bus outage, during which time the internal circuit breaker cell is modified to accept the new circuit breaker. A retrofill solution is often used in lieu of the direct replacement option for larger devices, such as main breakers and tie breakers. In these cases, because of the size of the replacement device, there may not be adequate room in the existing circuit breaker cell to allow for the intermediate cradle that is used in the direct replacement option. The state of the equipment and cost to do the work, including labor to complete the job, should be the determining factors in deciding which solution is best. Another consideration is the need for integrating new technologies to improve the performance of the circuit breaker and overall electrical system, such as a new solid state trip unit to replace an existing trip relay. The graph below compares the total installed cost, from the customer s perspective, for a range of solutions available to extend equipment life for low-voltage switchgear installations. The graph also shows when an upgrade in technology is included in the solution. Highest Installed cost Lowest New Retrofill External labor expense Technology upgraded Replacement Existing technology maintained In-shop recondition On-site maintenance Material expense Bar chart compares the total installed costs for lowvoltage switchgear installations. Costs are representative of price differences. Actual cost differences depend on the content and circumstances of each project. Spare parts It is important to note that in both retrofill and direct replacement options, new cubicle doors are provided to match the existing equipment and new circuit breaker face. 6 White paper for switchgear modernization options

Why Upgrade? Improved Reliability Dash-pot style or air break interrupting devices on existing circuit breakers may have reliability issues Many do not trip at all Those that trip are not repeatable and may be well outside the time-current coordination parameters Aging materials reduce equipment reliability Dielectric breakdown of insulating components Degradation of aging mechanical parts Reduced Maintenance Costs Older power circuit breakers require extensive periodic maintenance and overhaul, which is expensive and time consuming Lengthens outages May require outside support Many components for existing circuit breakers are no longer supported New parts may no longer be available The quantity and quality of used or reconditioned parts is decreasing Prices of parts are increasing Increased Capabilities Fault current interruption New circuit breakers are available with higher ratings In most cases the interruption capacity of the entire switchgear can be increased with an engineering study and a circuit breaker upgrade or replacement Arc flash limiting circuit breaker availability Trip unit accuracy and repeatability with new circuit breakers Power metering, monitoring and communication White paper for switchgear modernization options 7

Conclusion The most obvious benefit of upgrading existing electrical switchgear is the significant savings on costs that would have been dedicated to buying new equipment and not just the physical equipment, but the time and labor involved in specification, procurement, installation, testing and commissioning. A direct replacement or retrofill solution is a viable, cost-effective alternative to purchasing new equipment. In addition, the upgrade can be performed without major downtime and possible loss of production. Appendix Circuit Breaker Terminology ANSI: American National Standards Institute. Direct replacement: Retrofit process where a new circuit breaker (and adapter cradle for low voltage applications) fit into an existing switchgear cubicle. Interrupting rating: The highest current at rated voltage available at the incoming terminals of the circuit breaker. When the circuit breaker can be used at more than one voltage, the interrupting rating will be shown on the circuit breaker for each voltage level. The interrupting rating of a circuit breaker must be equal to or greater than the available short-circuit current at the point at which the circuit breaker is applied to the system. OEM: Original equipment manufacturer. Overcurrent: Any current in excess of the rated continuous current of equipment or the ampacity of a conductor. Primary disconnect contacts: An electrical plug-on connector in the main current path between the drawout components and the cradle mounted in the switchboard or switchgear. Racking interlock: An interlock to prevent racking of a drawout circuit breaker when the enclosure door is open by not allowing the racking crank to be inserted into the circuit breaker. Retrofill: Retrofit process where an existing switchgear cell and bus are modified to accept a new circuit breaker. Secondary disconnect contacts: An electrical plug-on connector in the secondary (control) circuit between a drawout circuit breaker and its cradle in the switchboard or switchgear. Trip unit: A programmable device that measures and times current flowing through the circuit breaker and initiates a trip signal when appropriate. UL: Underwriters Laboratories Inc. Schneider Electric USA, Inc. 9870 Crescent Park Drive West Chester, OH 45069 Tel: 513-777-4445 Fax: 513-755-5028 Document Number 1910DB1002 This document has been printed on recycled paper January 2011 tk 2011 Schneider Electric. All Rights Reserved.