Introduction 1/2 Industrial Cable Gland W Industrial Cable Gland WL Heavy Duty Industrial Cable Gland CW Industrial Cable Gland CZ Industrial Cable Gland 1W Industrial Cable Gland 1Z Industrial Cable Gland 2 3 5 6 7 8 9 10 I N D U S T R I L C L G L N D S CXT Industrial Cable Gland 11 Gland ccessories 12 Gland Kits 12 rass Gland Selection Chart 13 Wiping Glands 1 Fittings For Wiping Glands 15 Conduit Fittings Ingress Protection Index 17 ntry Thread Options 18 INDX 01
xis offers a wide range of Industrial Cable Glands for indoor and outdoor use. The Cable glands meet the performance requirements of S 6121 : Part I / S N 262 and are manufactured in brass to S 287 standard. ntry threads are available in Metric, PG, NPT & Imperial sizes. xis, by translating its Technological expertise, Manufacturing Process and Product pplication to innovative solutions ensures complete customer satisfaction 2
xis glands are being used worldwide and are supported by a wide network of distributors and wholesalers. Owing to our good track record of reliable supplies our customer base has spanned major sectors like Industrial, Power and Oil fields, just to name a few. xis has been dedicated to provide its customers, solutions, adding value to their business and also develop products as per their specific requirements, from short to large production run. This catalogue has been compiled and logically structured enabling the original equipment manufacturers, electrical contractors, distributors, wholesalers and retailers to find product information easily and efficiently. 3
I N D U S T R I L C L G L N D S TCHNICL DT Type Design Specification 1/2 1/2 Industrial Cable Gland rass indoor and outdoor cable gland highly suitable for all types of unarmoured cables, plastic or rubber sheathed cables. This gland provides a seal on outer sheath. Recommended to use PVC shroud for additional ingress protection. S 6121 : Part I : 1989 C Ingress protection Gland Material Finish Seal Material Cable Type Sealing Technique IP66 rass Plain rass or Nickel Plated Thermoplastic lastomer Unarmoured Displacement Type D Sealing rea Outer Sheath cross Flat ' Max 21.30 23.60 23.60 26.85 30. 35. 1.30 7.00 55.00 59.95 6.75 69.85 78.75 8.60 102.60 119.10 COD G00 G00S G00 G00L G00S G00L G00L G00L G00S G00L G00S G00L G0075S G0075L G0090L G0100L 0
TCHNICL DT Type Design Specification Ingress Protection rass indoor glands most suitable for single wire armoured, plastic or rubber sheathed cable. arth tags to be use for earth continuity. Recommended to use with shroud for additional ingress protection. C W KNURLING TYP S 6121 : Part I : 1989 IP3X W Industrial Cable Gland D I N D U S T R I L C L G L N D S Gland Material Finish Cable Type rmour Clamping rass Plain rass or Nickel Plated Steel Wire rmour Two Part rmour Lock cross Flat ' Max 21.00 21.00 23. 33..10.30 56.65 62.70 76. 92.70 05
I N D U S T R I L C L G L N D S TCHNICL DT Type WL Heavy Duty Industrial Cable Gland rass indoor glands most suitable for single wire armoured, plastic or rubber sheathed cable. Lockring provided for additional grip to the armour. arth tags to be use for earth continuity. WL glands are also supplied with integral earth facilities. Recommended to use with shroud for additional ingress protection. C WL Design Specification Ingress Protection Gland Material Finish Cable Type rmour Clamping S 6121 : Part I : 1989 IP3X rass Plain rass or Nickel Plated Steel Wire rmour Three Part rmour Lock D cross Flat ' Max 21.30 23.60. 31.10 3.00..90 8.70 57. 61.00 70.10 7.80 8.30 90.10 105.30 COD WL00 WL00 WL00L WL00S WL00L WL00L WL00S WL00L WL00S WL00L WL00S WL00L WL0075S WL0075L WL0090 06
TCHNICL DT Type Design Specification CW Industrial Cable Gland rass indoor and outdoor gland most popularly used with single wire armoured, plastic or rubber sheathed cable. Terminates and secured cable armouring and outer seal grips sheath of cable thus ensuring mechanical strength and earth continuity. arth tags to be use for earth continuity. CW brass glands are also supplied with integral earth facilities. Recommended to use PVC shroud for additional ingress protection. C CW S 6121 : Part I : 1989 I N D U S T R I L C L G L N D S Ingress Protection Gland Material Finish Seal Material IP 66 rass Plain rass or Nickel Plated Thermoplastic lastomer D Cable Type rmour Clamping Sealing Technique Steel Wire rmour Three Part (With Lock Nut) Compression Type Sealing rea Outer Sheath cross Flat ' Max 2. 2.00 27.17.75 3.30 2.90 9.30.80 61.70.75 73.90 78. 87. 96.00 105.30 COD CWG00 CWG00 CWG00L CWG00S CWG00L CWG00L CWG00S CWG00L CWG00S CWG00L CWG00S CWG00L CWG0075S CWG0075L CWG0090L 07
I N D U S T R I L C L G L N D S TCHNICL DT Type Design Specification CZ CZ Industrial Cable Gland rass gland suitable for steel tape armoured, plastic or rubber sheathed cables. Terminates and secure cable armouring and outer seal grips sheath of cable thus ensuring mechanical strength and earth continuity. CZ brass glands are also supplied with integral earth facilities. arth tags to be use for earth continuity. Recommended to use PVC shroud for additional ingress protection. S 6121 : Part 1 : 1989 C Ingress protection Gland Material IP 66 rass D Finish Seal Material Cable Type rmour Clamping Sealing Technique Plain rass or Nickel Plated Thermoplastic lastomer Steel Tape rmour Three Part (With Lock Nut) Compression Type Sealing rea Outer Sheath cross Flat ' Max 2. 2.00 27.17.75 3.30 2.90 9.30.80 61.70.75 73.90 78. 87. 96.00 105.30 COD CZG00 CZG00 CZG00L CZG00S CZG00L CZG00 CZG00S CZG00L CZG00S CZG00L CZG00S CZG00L CZG0075S CZG0075L CZG0090 08
TCHNICL DT Type Design Specification Ingress Protection 1W Industrial Cable Gland rass indoor and outdoor cable glands highly suitable for single wire armoured, plastic or rubber sheathed cables. Provides grip to the cable with outer and inner seals. Used popularly in most climatic conditions weatherproof and waterproof. arth tags to be use for earth continuity. 1W brass glands are also supplied with integral earth facilities. Recommended to use PVC shroud for additional ingress protection. C 1W S 6121 : Part I : 1989 IP 66 D I N D U S T R I L C L G L N D S Gland Material rass Finish Seal Material Plain rass or Nickel Plated Thermoplastic lastomer Cable Type rmour Clamping Steel Wire rmour Three Part rmour Lock Sealing Technique Compression & Displacement Type Sealing rea (s) Inner & Outer Sheath cross Flat ' Max 2.10 2.10 27.17.75 35.85 2.90 9.30.80 61.70.75 73.90 78. 87. 96.00 105.30 COD 1W00 1W00 1W00L 1W00S 1W00L 1W00L 1W00S 1W00L 1W00S 1W00L 1W00S 1W00L 1W0075S 1W0075L 1W0090 09
I N D U S T R I L C L G L N D S TCHNICL DT Type Design Specification 1Z 1Z Industrial Cable Gland rass indoor and outdoor cable glands suitable for steel tape armoured, plastic or rubber sheathed cable. Provides grip to the cable with outer and inner seals. Used in most climatic conditions weatherproof and waterproof. arth tags to be use for earth continuity. 1Z brass glands are also supplied with integral earth facilities. Recommended to use PVC shroud for additional ingress protection. S 6121 : Part 1 : 1989 C Ingress protection Gland Material Finish Seal Material Cable Type rmour Clamping Sealing Technique IP 66 rass Plain rass or Nickel Plated Thermoplastic lastomer Steel Tape rmour Three Part rmour Lock Compression & Displacement Type D Sealing rea (s) Inner & Outer Sheath 10 cross Flat ' Max 2.10 2.10 27.17.75 35.85 2.90 9.30.80 61.70.75 73.90 78. 87. 96.00 105.30 COD 1Z00 1Z00 1Z00L 1Z00S 1Z00L 1Z00 1Z00S 1Z00L 1Z00S 1Z00L 1Z00S 1Z00L 1Z0075S 1Z0075L 1Z0090
TCHNICL DT Type Design Specification CXT Industrial Cable Gland rass indoor and outdoor cable gland suitable for braided armoured type, plastic or rubber sheathed cables. This gland provides seal on outer sheath. Recommended to use with PVC shroud for additional ingress protection. C CXT S 6121 : Part 1 : 1989 I N D U S T R I L C L G L N D S Ingress protection Gland Material Finish Seal Material Cable Type Sealing Technique IP 66 rass Plain rass or Nickel Plated Thermoplastic lastomer raided rmoured Type Displacement Type D Sealing rea Outer Sheath cross Flat ' Max 21.3 23.6 23.6 26.85 30.5 1.3 7 55 59.95 COD CXT00 CXT00S CXT00 CXT00 CXT00L CXT00L CXT00L CXT00S CXT00L 11
I N D U S T R I L C L G L N D S GLND CCSSORIS LOCKNUTS Locknuts are recommended to use with cable glands to secure it to a gland plate or to equipment. It is highly recommended to use brass locknut with gland for all the atmospheric conditions. Sizes available from mm to 90mm (Imperial and PG sizes also available) RTH TGS arth tags are installed between the cable gland and equipment to provide earth continuity as specified in S 6121 Part 5, 1993 Sizes available from mm to 90mm PVC SHROUD The shroud are recommended to use with all cable glands to provide additional ingress protection and to minimize the risk of dirt or any foreign substance gathering around gland body. PVC Shrouds are denoted by gland reference number and are compatible with each glands size. GLND KIT xis provides ready to use gland kit which consists of all the basic components required to terminate the cable to the equipments. See kit details below. Kit Details Size 90 Component / Kit Glands, Locknuts, arthtags, PVC Shrouds and Screws 2 a. Gland, Locknut, arthtag, PVC Shroud and Screw 1 a. 12 Note: For 1/2 Glands arth Tag not required.
RSS GLND SCTION CHRT 600 / 1000v stranded copper conductors pvc insulated with steel wire armour and PVC sheathed overall. Cable to S 6 : 1997 Nom. rea (mm2) 1.5 2.5 6 10 35 70 95 1 1 185 2 300 300 0 0 0 800 1000 Cable Size Conductor Neutral 35 70 70 95 1 1 185 185 1 S S 2 S S 3 S S 75S 31/2 S S 75S 75 75 Numbers of Cores S S 75S 75 75 75 5 7 10 12 19 27 37 8 I N D U S T R I L C L G L N D S 600 / 1000v stranded copper conductors xlpe/swa/pvc cable and PVC sheathed overall. Cable to S 567 : 1989 Cable Size Conductor Numbers of Cores Nom. rea (mm2) 1.5 2.5 6 10 35 70 95 1 1 185 2 300 300 0 0 0 800 1000 Neutral 35 70 70 95 1 1 185 185 1 S S 2 S S S S 3 S S 75S 31/2 S S 75S 75S 75 S S 75S 75 75 5 7 10 12 19 27 37 8 S 13
I N D U S T R I L C L G L N D S WIPING GLND Material : rass Finish : Natural R F F G 10 H HOLS ØJ 11 6 HOLS ØJ 12.5 12.5 3 Ø C ØC ØD Gland Size X & Y Gland Size Z ØD Gland Size Dia over metal sheath of cable (mm) Dimention in mm C D F G H J R Code X 12 to 51 137 90 60 19 90 90 66 66 12 12 WGX Y to 78 155 95 89 11 123 95 86 1 1 WGY Z to 9 195 1 108 190 100 1 WGZ 1
FITTINGS FOR WIPING GLNDS Insulating Plates Material : Thermoplastic lastomer or Cork D ØG Insulating Plate PX PY PZ ØH C Dimension in mm ØH C D G H 190 90 11 66 86 90 123 66 95 1 Ø 60 90 108 Code PX002 PY001 PZ003 6 HOLS ØG I N D U S T R I L C L G L N D S Insulating ush Material : Neoprene Ø rmour Clamp Material : M.S Strip Finish : lectro Zinc Plated D Ø ØC ØC Insulating ush Dimention in mm C D Gland Size Dimention in mm C Code 15 11.2 22 28 10 X 1 108 73 CX 18 1 28 28 10 Y 175 15 103 CY Z 190 0 123 CZ Gland Size X Y Z Insulating Plate PX PY PZ Insulating ush 15
I N D U S T R I L C L G L N D S CONDUIT FITTINGS Male Female ushes Material:rass as per S 287 Finish:rass as natural. Sizes:Metric : mm to mm (Short and Long patterns) daptors Material:rass as per S 287 Finish:rass as natural or Nickel plated. Sizes:Metric : 12mm to mm Imperial: 1/2 to 2 lso available with swivel type fittings. Flexible Conduit PVC Coated Flexible Conduit Nylon Coated s per S 731 Material:G. I. Strip Coating:Temperature resistant PVC IP Rating:IP 65 or IP with standard fittings Working Temperatures : Min : C Max : +70 C Colour:lack Sizes: Metric : 12mm to mm Imperial : 1/2 to 2 s per S 731 Material:G. I. Strip Coating:Nylon IP Rating:IP 65 or IP with standard fittings Working Temperatures : Min : 30 C Max : +110 C Colour:lack Sizes: Metric : 12mm to mm Imperial : 1/2 to 2
INGRSS PROTCTION INDX 1 X 0 1st Digit : IP No Test No Protection Protection gainst Solids. mm Protected against solid objects larger than mm diameter X 0 2nd Digit : 1 IP No Test No Protection Protection gainst Solids. Protected against drops of water falling vertically I N D U S T R I L C L G L N D S 2 12.5mm Protected against solid objects larger than 12.5 mm diameter 2 Protected against drops of water falling at up to 15 from the vertical 3 2.5mm Protected against solid objects larger than 2.5 mm diameter 3 Protected against rain at up to 60 from the vertical 1mm Protected against solid objects larger than 1 mm diameter Protected against splashing of water from all directions 5 Protected against dust 5 Protected against jets of water from all directions 6 Completely protected against dust (Dusttight) 6 Protected against projections of water from all directions 7 1m 15cm Protected against the effect of immersion 8 Protected against the effects of submersion 17
NTRY THRD OPTIONS Cable Gland Size ISO Metric / S S 75S 75 90 M M M M M M M M M M M M75 M75 M90 1/2" 1/2" 1/2" 1/2" 3/" 1" 11/" 11/2" 2" 2" 21/2" 21/2" 3" 3" 11 11 13.5 21 29 36 36 2 8 1/2" 1/2" 1/2" 3/" 1" 11/" 11/2" 2" 2" 21/2" 21/2" 3" 3" 5/8" 3/" 3/" 3/" 1" 11/" 11/2" 2" 2" 21/2" 21/2" 3" 3" 31/2" NPT P.G. PF / SP Imperial 18