February 2010 Number 201001. Vector Network Analyzer upgrade to SureCAL Power Sensor and RF Components Packages



Similar documents
Agilent 8753ET/8753ES Network Analyzers

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

Agilent Measuring Noninsertable Devices

Applying Error Correction to Network Analyzer Measurements. Application Note Table of Contents. Page

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Tuning a Monopole Antenna Using a Network Analyzer

Agilent Test Solutions for Multiport and Balanced Devices

2. The Vector Network Analyzer

Advanced Calibration Techniques for Vector Network Analyzers

R3765/67 CG Network Analyzer

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

Using Simple Calibration Load Models to Improve Accuracy of Vector Network Analyzer Measurements

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Agilent 10 Hints for Making Better Network Analyzer Measurements. Application Note B

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Six-Port Reflectometer: an Alternative Network Analyzer for THz Region. Guoguang Wu

Measurement & Modeling Device Characterization Solutions

MAURY. VNA Calibration Kits, Microwave Components & Adapters. Calibrate With Confidence IN THIS CATALOG:

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

Network Analysis. Specifying calibration standards for the HP 8510 network analyzer Product Note A

Measurements in 75 Ω Coaxial Transmission Lines

Validation of On-Wafer Vector Network Analyzer Systems

R&S ZCxxx Millimeter-Wave Converters Specifications

Agilent 8720 Family Microwave Vector Network Analyzers

Field Calibration Software

Cryogenic Performance of Millitech Model FBI-22 Waveguide Isolator.

Techniques for Precise Cable and Antenna Measurements in the Field

Network Analyzer Basics- EE142 Fall 07

Impedance 50 (75 connectors via adapters)

Agilent PNA Network Analyzers 10 MHz to 110 GHz

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

S-PARAMETER MEASUREMENTS OF MEMS SWITCHES

A Network Analyzer For Active Components

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements

MEASUREMENT OF CRYOGENIC PERFORMANCE OF 4-8 GHz PAMTECH ISOLATORS S/N Juan Daniel Gallego Isaac López Fernández Carmen Diez González

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer

Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

RF Network Analyzer Basics

AMERICAN NATIONAL STANDARD

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Carrying precision into the field. 14 New FieldFox Handheld Analyzers Deliver Benchtop Accuracy, MIL-spec Durability

Agilent Specifying Calibration Standards for the Agilent 8510 Network Analyzer

Eye Doctor II Advanced Signal Integrity Tools

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

You will need the following pieces of equipment to complete this experiment:

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Agilent PN In-fixture Microstrip Device Measurements Using TRL* Calibration. Product Note

One Port Network Analyzer

Improving Network Analyzer Measurements of Frequency-translating Devices Application Note

Experiment 7: Familiarization with the Network Analyzer

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

Software Utility VNA Frequency Converter Leveling Tool Getting Started

Agilent AN Improving Throughput in Network Analyzer Applications. Application Note

ELECTRICAL CHARACTERISATION OF SMA CONNECTORS FOR CRYOGENIC AMPLIFIERS. Carmen Diez Juan Daniel Gallego Isaac López Rafael García.

Vector Network Analyzer (VNA) Calibration: The Basics

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

E5092A Configurable Multiport Test Set

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

AGILENT E5071C ENA NETWORK ANALYZER

Calibration Procedure for Measuring S-Parameters in Balun Applications on 150-Ω High-Speed Cables

Site Master Cable and Antenna Analyzer with Spectrum Analyzer

Agilent AN In-Fixture Measurements Using Vector Network Analyzers

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

HP 8753E RF Vector Network Analyzer

A New Concept of PTP Vector Network Analyzer

A Guide to Calibrating Your Spectrum Analyzer

A Comparison of Measurement Uncertainty in Vector Network Analyzers and Time Domain Reflectometers. White Paper

Michael Hiebel. Fundamentals of Vector Network Analysis

Basic of Load Pull Measurements Active and Passive load pull & Harmonic load pull testbench

Agilent Millimeter-Wave Network Analyzers 10 MHz to 110 GHz, with Extensions to 0.5 THz

A sures the complex scattering parameters of a microwave

Table Of Contents. Introduction. New Products. Index. Adapters, Cables and Connectors. Amplifiers. Attenuators. Detectors

Application Guide to RF Coaxial Connectors and Cables

Automatic compression measurement using network analyzers

DSA800 Series Spectrum Analyzer

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Transmitter Interface Program

Measuring RF Parameters of Networks Bill Leonard NØCU

Mini-DINs. Low PIM Cable Assemblies and Coaxial Adapters. Always Thinking

Application Note Noise Frequently Asked Questions

Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

Techniques for precise cable and antenna measurements in the field

J. Zhang, J.-Z. Gu, B. Cui, andx. W. Sun Shanghai Institute of Microsystem & Information Technology CAS Shanghai , China

R&S ZVA Vector Network Analyzer Specifications

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

iva Cable & Antenna Analyzer

The Design & Test of Broadband Launches up to 50 GHz on Thin & Thick Substrates

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

System Verification Software (SVS)

Agilent N9911X Economical Waveguide Calibration Components

Spectrum Analyzers And Network Analyzers. The Whats, Whys and Hows...

Keysight Technologies Compatibility of USB Power Sensors with Keysight Instruments. Application Note

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Power Amplifier Gain Compression Measurements

USB Smart Power Sensor

Transcription:

February 2010 Number 201001 Vector Network Analyzer upgrade to SureCAL Power Sensor and RF Components Packages Overview: This Technical Note describes the addition of Vector Network Analyzer (VNA) measurement capabilities to the Power Sensor and RF Components Packages. Topics covered in this technical note: Measurement Format Devices Supported New and Extended Support Device Profile Structure Supported VNA s VNA Test Set and Calibration Kit Descriptions and Capabilities VNA Test Set Definition Files VNA Calibration Kit Definition Files Supported Calibration Kit Types Supported Calibration Types Calibration Sequence Sliding Load Sequence Saving Calibrations Adapter Techniques 1

Measurement Format: The VNA addition provides the Power Sensor and RF Component Packages the ability to now support both 1 and 2 port measurement standards. The VNA upgrade is designed to be transparent to Power Sensor and RF Component Package users. Except where new measurements are added as a result of expanded capabilities, the format of both current and new calibration procedures adhere to all previously defined structures. The ability of the user to freely manipulate, save and assign modified profiles developed from default parameters remains unchanged. Devices Supported: Support for the following new devices has been added. Filters Power Splitters Power Dividers Isolators Mismatches Support has been extended to the following devices. Fixed, Decade, Programmable Attenuators Directional Couplers Terminations Power Sensors New and Extended Support Device Profile Structure: New device profiles appear in the profile pick list with a Type Default and a Status Assigned. To avoid profile index conflicts, extended support device profiles appear in the profile pick list with a Type Default and a Status Floating. To automatically recall these extended support profiles the Status will need to be reassigned by the operator using the Assign function. VNA Support: The VNA s are addressed in the Flexible Standards table as integrated systems. Identification of system components such, as VNA sources, within the Flexible Standards table is not required. Since VNA configurations between manufacturers and model numbers can vary, care must be taken to verify VNA primary and secondary as well as pass through addresses do not conflict with other devices within the table. VNA Test Set and Calibration Kit Descriptions and Capabilities: Identification of both the test set and calibration kit being used is critical to determining measurement capabilities and uncertainties. The process of identifying the specific model numbers is provided via a pick list. The operator is queried at the start of a new procedure or whenever a profile parameter is altered. VNA Test Set Definition Files: Each VNA requires the use of an internal or external S Parameter Test Set to perform error corrected S-Parameter measurements. The Test Set Definition Files contains performance values derived from both simple specifications tables and calculations simulating combined 2

performance of test set, VNA and calibration kit components. These values are based on theoretical performance and not actual measured values. They are not serial number specific. The test set files are stored in the SureCAL DATA folder and are identified by manufacturer/model number with an extension of.tsd. The test set information is read from the.tsd file and used to optimize VNA performance as an error Corrected system. In the error corrected mode, the VNA s performance parameters have been optimized to the defined limits of the calibration kit, VNA configuration and skill of the operator. Test Set (.TSD) file example for the Agilent/HP 8514A.50-18GHz TEST SET 8514A 18 GHz DETENORB; ERROR TERMS ERROR TERM FREQUENCY(GHz) ERROR TERM VALUE(LINEAR) REFL TRACKING.5 TO 2 -.0070000 2 TO 8 -.0070000 8 TO 18 -.0070000 TRAN TRACKING.5 TO 2 -.0139000 2 TO 8 -.0139000 8 TO 18 -.0139000 ISOLATION.5 TO 2 -.0000060 2 TO 8 -.0000018 8 TO 18 -.0000028 NOISE FLOOR.5 TO 2 -.0001400 2 TO 8 -.0000428 8 TO 18 -.0000530 REFL & TRAN TRACKING ERROR TERMS ARE TAKEN FROM THE HP85131F CABLE SET MAGNITUDE STABILITY SPECIFICATION. (0.12dB = 0.0139 LIN MAG) NOTE REFL TRACKING IS SIMPLY HALF THE TRAN TRACKING VNA Calibration Kit Definition Files: Each VNA also requires the use of a calibration kit to perform error corrected measurements. The purpose of the cal kit definition file is to provide electrical and mechanical definitions of the calibration kit components. These definitions are based on kit/device specifications and not actual measured values. They are not serial number specific. The calibration kit files are stored 3

in the SureCAL DATA folder and identified by manufacturer/model number with an extension of.ckd. The calibration kit information is read from the data file and inputted to the VNA. This information is used when performing the VNA calibration function. The device specific information ultimately allows the characterization of the VNA to perform measurements in the error corrected mode. In the error corrected mode, the VNA s performance parameters have been optimized to the defined limits of the calibration kit and skill of the operator. Calibration Kit (.CKD ) file example for the Agilent/HP 85054D N CAL KIT 85054D 18 GHz 18 GHz FIXED TERM ERROR TERMS & CAL COEFFICIENTS ERROR TERM FREQUENCY(GHz) ERROR TERM VALUE(LINEAR) DIRECTIVITY 0 TO 2 -.0100000 2 TO 8 -.0158000 8 TO 18 -.0200000 LOAD MATCH 0 TO 2 -.0100000 2 TO 8 -.0158000 8 TO 18 -.0200000 SOURCE MATCH 0 TO 2 -.0119000 2 TO 8 -.0232000 8 TO 18 -.0367000 ********************************************************** STANDARD (TEST PORT SEX) LENGTH STRAY C/L LOSS FEMALE OPEN 57.993 (E-12) * 89.939 (E-15).93.0173860 * 2536.8 (E-27) * -264.99 (E-36) * 13.4 (E-45) MALE OPEN 22.905 (E-12) * 104.13 (E-15).93.0068667 * -1943.4 (E-27) * 144.62 (E-36) * 2.2258 (E-45) FEMALE SHORT 63.078 (E-12) * 0.7563 (E-12) 1.1273.0189100 * 459.88 (E-24) * -52.429 (E-33) * 1.5846 (E-42) MALE SHORT 27.990 (E-12) * -0.1315 (E-12) 1.3651.0083912 * 606.21 (E-24) * -68.405 (E-33) * 2.0206 (E-42) M-M ADAPTER 196.00 (E-12) 2.2.0587590 Supported Calibration Kit Types: Since Calibration Kits are identified and quantified through.ckd files, there are no restrictions between VNA and Calibration Kit manufacturers. Requirements are based on compatibility between frequency, connector and calibration type. 4

Supported Calibration Types: Support is provided for several types of Short, Open, Load and Thru (SOLT) 1 and 2 port calibrations. Selection of Calibration Types is available through the Standards Profile function. Calibration types are labeled as follows: Broadband Load Fixed/Sliding Load Waveguide E-Cal (Support for Agilent PNA E-Series and PNA N-Series only) Calibration Sequence: Calibrations are guided with graphic instructions for each step. The contrasting sequence of the calibration devices (i.e. Open/Short, Short/Open ) is a result of two factors, elimination of the possibility of requiring two of the same sex calibration devices and deference to the most limiting VNA within the support list. Sliding Load Sequence: The sliding load is measured at five unequally spaced positions. The measured data at each frequency point is used to calculate the vector sum of the directivity error and load reflection. Five unequally spaced points represents the best compromise for determining a complete 360 degree change in phase while remaining compatible with the largest possible number of calibration kits. For additional details on the sliding load calibration sequence and a test example refer to SureCAL Technical Note 200702. Saving Calibrations: The most current calibration is saved and can be recalled for a 24 hour period. The saved calibration details are compared to the current requirement using discriminators of connector type, calibration type and number of frequency points. If in agreement, the option of using this saved calibration is presented to the operator. The operator can decline the saved calibration and select a new calibration at this time. Adapter Techniques: For ease of operation and limited capability within some supported VNA s, the initial release of the RF Components VNA Update supports adapter substitution techniques. This method will yield successful results when calibration kit, metrology grade, equal electrical length adapters are used. For additional details and a test example refer to SureCAL Technical Note 200703. 5