SURGE PROTECTIVE DEVICES



Similar documents
wietap wietap Overvoltage Protection Tensions running high

CATALOGUE SURGE PROTECTION LOW VOLTAGE

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Surge Protection for Photovoltaic Systems

White paper. ABB solutions for switching and protection of low speed wind turbines

Unified requirements for systems with voltages above 1 kv up to 15 kv

ABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40

R.C.C.B. s two-pole LEXIC

ADM1TE 5/30A DIN rail single phase two wire energy meter

How To Build A Low Voltage Capacitor Lvcp

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Electrical safety and protection devices

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Intersection Preassembled 19-inch Rack

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Class I surge protection with sparkover gaps

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Quick Connect. quick - simple - efficient.

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Surge protection for emergency alarm systems

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

How can a charging station for electric vehicles be set up simply and safely?

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Relés e Contatores de Estado Sólido SIRIUS

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Power Meter Series 700

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Electrical Shore Connections / Cold Ironing

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Arc Terminator Active Arc-Resistant Switchgear

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

DEHNshield Application-optimised multipole combined lightning current and surge arrester

Redundancy Module QUINT-DIODE/40

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

DC Combiner box and AC solutions. Leadership in circuit protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

3-phase, bidirectional energy meter

KNX Interface. User Manual PM00A00IRI

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

The complete range of consumer switchboards and switchgear

Thermistor motor protection

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

ZS25 Screw Clamp Terminal Blocks Feed-through

A project to optimise quality and energy efficiency must include metering

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

RM4TG20 three-phase network control relay RM4-T - range V

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Surge Protection. Electrical Installations. Photovoltaic. Telecom. Data. Radiocommunication

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Safety technique. Emergency stop module BO 5988 safemaster

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Telephone- and leased line modem for industrial applications TD-36

Thermal-Magnetic Circuit Breaker M1-..

How To Understand The Electrical Power Supply Of A Power Supply System

Trip circuit supervision relay. Type RXTCS

38 Series - Relay interface modules A

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

38 Series - Relay interface modules A

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PHOENIX CONTACT Features

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

ICON Server box installation manual Rev. 1.1

48 SERIES Relay interface modules 10 A

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

MasterINTERFACE 39 Series - Relay interface modules

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Transcription:

SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood of equipment dielectric failure. Several components can be used to limit and/or eliminate the surges. This document provides general specification for the surge protective devices (SPDs) to be installed in LV electrical systems. SPDs shall be installed near the origin of the installation or in the main switchboard assembly, however additional SPDs might be necessary to protect sensitive equipment and when the distance from the main SPD to the next distribution board is big (> 30m). These secondary SPDs shall be coordinated with the upstream SPDs. 2. SPECIFICATIONS 2.1. STANDARDS The accomplishment of the following standards are required: STANDARD 2.1.1 EN 61643-11 Type 1, Type 2 and Type 3. Surge protective devices connected to low voltage power distribution systems. Part 1. This is the European variation of IEC 61643-1 which is mandatory in European countries 2.1.2 IEC 61643-1 Class I, Class II and Class III test Edition 2 ( march 2005): Surge protective devices connected to low voltage power distribution systems. Part 1 2.1.3 IEC 60364-4-44 Electrical installations of buildings - Part 4-443: Protection against overvoltages of atmospheric origin or due to switching 2.1.4 IEC 60364-5-53 Electrical installations of buildings - Part 5-534: Devices for protection against overvoltages 2.1.5 IEC 60529 Degrees of protection provided by enclosures (IP code) 2.2. CERTIFICATIONS 2.2.1 Both EN & IEC Certifications are required. 2.2.2 CE marking (to IEC61643-1 Class I, Class II and Class III test) METHOD Third Party Lab Third Party Lab or self certified A safety mark of conformity shall be required: ÖVE, NF, KEMA,. SPD Engineering Specification Latest.doc 1

2.3. SURGE CURRENT RATINGS AND PROTECTION LEVELS Iimp (Type 1)/ Imax (Type 2): The value of Iimp shall not be less than 12,5kA for each mode of protection [IEC 60364-5-534]. In case the connection type 2 is used (see 2.7.1.1) the value of Iimp (N-PE) shall not be less than 50 ka for three-phase systems and 25 ka for single-phase systems [IEC 60364-5-534]. The preferred values for the impulse current for Type 1 test SPD are 35 /50 ka (L-PE or L-N), 50kA (N-PE single phase systems when using connection type 2) and 100kA (N-PE three phase systems when using connection type 2) The preferred values for the maximum surge current rating Imax for Type 2 tests SPDs are 8kA, 20kA, 40kA and 65kA. In: The nominal discharge current In shall not be less than 5kA for each mode of protection [IEC 60364-5-534]. Up: The protection level of the protective device (Up) shall not be higher than the level of overvoltage category II (2,5kV) [IEC 60364-4-443]. If sensitive electronics is to be protected the protection level shall not be higher than 1,5 kv. Uc: For a 230/400V network it is recommended the Maximum Continuous Operating System (Uc) to be no less than 340 V. Response time: The response time of Type I SPD shall be no more than 1μs, the response time of Type 2 SPD shall be no more than 25 ns. 2.4. MECHANICAL REQUIREMENTS SPD Engineering Specification Latest.doc 2

2.4.1 Housing Material Housing material must conform the necessary standards (including self flame-extinguishing characteristics), 2.4.2 Required Housing Markings Compliance to IEC 61643-1 Section 6.1.2 Test certification marks 2.4.3 Terminal Connection 35mm2 is preferred 2.4.5 End of Life Indicators All products (except products to be connected N-PE) will have an End of Life visual indicator. The indication shall be LED or mechanical. If LED is used must be ON for normal operation (green color). When reach the end of life LED or mechanical indication must be Red. 2.4.6 Mounting Method Standard Snap on 35 mm DIN Rail mounting. 2.4.7 Shock, Impact, Reference IEC 60068 Vibration 2.4.8 Enclosure Protection Comply with IEC 60529 IP20 rating 2.5. ENVIRONMENTAL REQUIREMENTS 2.5.1 Minimum Operating Range -5 C to +40 C 2.5.2 Relative Humidity 5% to 90% 2.5.3 Altitude 2000 Meters minimum without derating 2.6. ELECTRICAL REQUIREMENTS 2.6.1 Remote Indication 2.6.2 Thermal Protection 2.6.3 Short circuit Protection 2.6.4 System Frequency 2.6.5 Breaker Coordination Optional. When required use Dry Contacts (250 VAC 1.5A, 125V 3A desired, min. 0.25 Amps at 250V required). Thermal fusing is required for MOVs. Not required for GDTs External dedicated circuit breaker to the SPD is required to guaranty the continuity of service and electrical installation safety in case of short circuit inside the SPDs. 47 Hz to 62 Hz Provide coordinated disconnect device requirements which will be put in the literature and on product as required by the manufacturer recommendations. SPD Engineering Specification Latest.doc 3

3 INSTALLATION RECOMMENDATIONS 3.1 SPD configuration depending on the grounding system: 3.1.1 TT systems (connection type 2): 3.1.2 TN-S, TN-C systems: For TN-S, TN-C systems it can be used connection type 2 (see 2.7.1.1) or alternatively connection type 1 as per below (if there is significant distance between the N-PE bonding point it shall be used and additional SPD N-PE): SPD Engineering Specification Latest.doc 4

3.1.3 IT systems: 3.2 Connecting conductors: The length of the connecting conductors from the lines to the SPD added to the cable conductor from the SPD to the main earth terminal shall be less than 0,5 m (IEC60364-5-53). The cross section of the cables shall not be less than 4 mm². When there is a lightning protection system, for type 1 products the cross section shall not be less than 16 mm ². SPD Engineering Specification Latest.doc 5

3..3 External dedicated protection: An external dedicated protection will be installed to protect against overcurrent and consequences of SPD failure and to optimize the continuity of service.... SPD Engineering Specification Latest.doc 6