MiCOM P432 and P439. Distance Protection and Control Units. Protection Relays
|
|
|
- Bartholomew Wells
- 10 years ago
- Views:
Transcription
1 01 MiCOM P432 and P439 Distance Protection and Control Units The MiCOM P432 and P439 are cost effective one-box solutions for integrated numerical distance protection and control. P439 in case 40TE P432 or P439 in case 84TE Customer Benefits Protection and Control in one box Huge number of predefined bay types 1A/5A software setting Two communicationinterfaces (for SCADA and TU) Numerous switchable communication protocols (for SCADA interface) The broad spectrum of protection functions enables the user to cover a wide range of applications in the area of selective short-circuit protection, ground fault protection and overload protection. They can be ap plied in all kind of medium-, highand extra-high-voltage systems. In addition, numerous control functions are available. Thanks to the provision of four setting groups, the devices are readily adapted to varying conditions in system operation. The control functions are designed for the control of up to six (P439) or ten (P432) electrically operated switchgear units equipped with electrical check-back signaling located in the bay of medium- or high-voltage substations.for the selection of the bay type the devices are provided with over 250 predefined bay types and allow download of customized bay type. The intuitive user interface and the various communication interfaces allow easy control and monitoring of the switchgear units, simple and comprehensive setting as well as access to readings of extensive recordings. Numerous integrated communication protocols provide interfacing to almost any kind of substation control or SCADA system. Furthermore the integrated InterMiCOM protection interface provides direct end-to-end communication between two protection devices. The standard 19 modular case of the P432 and P439 with a user-selected number of plug-in modules provide a flexible solution for easy integration of the devices into the substation. The devices are available for flush mounting as well as wallsurface mounting. P432_0837en_QxP.indd 1 11/29/ :02:17 AM
2 02 APPlicATion Distance protection and control units MicoM P432 and P439 provide a wide range of protection and control functions. The integrated functions reflect the different requirements in system protection and control. The preferred applications are as follows: P439: MV systems with 3pole tripping only; less complex bays P437: HV and EHV systems with 1pole or 3pole tripping; more complex bays. Further options are provided for various protection and control requirements for example increasing the number of switchgear units from 3 to 10 for control and monitoring and selection of automatic synchronism check. Global functions The following global functions are available in the devices: Parameter subset selection (4 alternative setting groups) Metering Operating data recording Overload recording incl. overload data acquisition Ground fault recording incl. ground fault data acquisition Fault recording of all CT/VT inputs and binary events incl. fault measurands (e.g. fault location). Functions overview P439 P DIST Distance Protection (No. of measuring systems) (1) (3) Mutual compensation - option PSIG Protective signaling (channel aided scheme logic) 50/27 sotf Switch on to fault protection 68 PSB Power swing blocking and out-of-step tripping MCMon Measuring-circuit monitoring (CT/VT supervision buoc Backup overcurrent-time protection 50/51 P,Q,N DTOC Definite-time overcurrent protection 51/67 P,Q,N IDMT Directional Inverse-time overcurrent protection 67N GFSC Ground fault (short-circuit) protection (Br.: Directional earth fault protection, DEF) N GSCSG Ground fault (short-circuit) protection signaling (Br.: DEF scheme logic) - 32 P<> Directional power protection - 49 THEM Thermal overload protection 27/59 P,Q,N V<> Over-/undervoltage protection 81 O/U f<> Over-/underfrequency protection TGFD Transient ground fault direction determination option - GFDSS Ground fault direct. determ. using steady-state values - GFTP Ground fault tripping - GFsiG Ground fault protection signaling - 25 ASC Automatic synchronism check option option 79 AC Auto-reclosing control 3p 1/3p LIMIT Limit value monitoring LOGIC Programmable logic DEV Control and monitoring of switchgear units 3 or 6 3, 6, 10 (option) (option) CMD_1 Single-pole commands sig_1 Single-pole signals ILOCK Bay interlock COUNT Binary counter COMMx 2 comm. interfaces, protection comm. interface InterMiCOM option option IIGB IIG-B input option option INP/OUTP Binary inputs / output relays (maximum number) 40 / / 26 MEAsi/ Analog I/O MEASO (2x 20 ma outputs, 20 ma input, TD inputs) option option P432_0837en_QxP.indd 2 11/29/ :02:18 AM
3 03 Main FUNCTiONS V/V nom or V/V nom / 3 V< fw 1,0 0,5 70 1,0 2,0 I> I>> Z r Fault Detection Characteristics Z fw,pp ZfW,PG Functional overview Z fw ß I/I nom fw,pg fw,pp Main functions are autonomous function groups and can be individually configured or disabled to suit a particular application. Function groups that are not required and have been disabled by the user are masked completely (except for the configuration parameter) and functional support is withdrawn from such groups. This concept permits an extensive scope of functionsand universal application of the device in a single design version, while at the same time providing for a clear and straight-forward setting procedure and adaptation to the protection and control task under consideration. DiSTANCe POTeCTiON The devices are equipped with elaborate fault detection elements that can be adapted to the individual application. They provide reliable fault detection and fault type determination even under difficult system conditions. The following criteria are continuously monitored: Overcurrent (I>>) Undervoltage (V<) Underimpedance with load blinding (Z<) Ground fault detection adaptable to system grounding. All fault detection measurement elements operate simultaneously. Control/Monitoring of 3, optional up to 6 or 10 resp. switchgear units DEV ILOCK Communication COMM1 COMM2 to SCADA / substation control / TU / modem... via S485 or Fibre Optics using IEC , -103, Modbus, DNP3, Courier IIGB Self Monitoring LIMIT ecording and Data Acquisition Metering Overload rec. Ground flt. rec. Fault rec. V ref 21 DIST 50/27 SOTF VTS/CTS MCMON 51 P,N BUOC 50/51 P,Q,N DTOC 51/67 P,Q,N IDMT 67N GFSC 49 THEM 32 P<> TGFD 25 ASC 79 AC I V I N,par PSIG 68 PSB 85-67N GSCSG 27/59 P,Q,N V<> 81 O/U f<> GFDSS GFSIG GFTP LOGIC scheme signalling conventional InterMiCOM serial COUNT SIG_1 CMD_1 MEASI MEASO always available optional or specific Distance Protection and Control P432/P439 (Description of ANSI code nos. see Functions Overview) MicoM P432 and P439 provide a wide range of protection and control functions needs. P432_0837en_QxP.indd 3 11/29/ :02:18 AM
4 04 Inrush stabilization and fuse failure monitoring (VT circuit supervision) are integrated. A well proven voltage memory eliminates all problems with directional determination in case of small fault voltage, CVT transients or in series compensated lines applications. Six distance zones can be set in total. Each zone can be set as forward, backward or nondirectional to suit requirements. Zone 1 extension is provided and controlled by integrated functions such as auto-reclosing control or protective signaling or by an external signal. Special zone 4 is provided, to allow auto-reclosing only on the overhead-line section in cable/line systems or to compensate the bundle conductor effect. P432 could optionally be equipped with an additional CT input to measure the residual current of a parallel line to provide mutual coupling compensation. 45 α 1 1,PG σ 1 1 OveCUeNT POTeCTiON various multi-stage, partly directional OC elements, with instantaneous or timed operation are provided for complementary protection schemes. SwiTCH ON TO FAUlt POTeCTiON Closing of a circuit breaker might inadvertently lead to a short-circuit fault due to a maintenance ground clamp not yet removed, for example. Switch on to fault protection provides an undelayed protective tripping during a settable time after a manual close command has been issued. Power swing blocking / OUT-OF- STep TiPPing Power swings between generators due to severe load variations or system faults may cause measured impedances to enter distance zones. To avoid incorrect tripping, the devices measure the rated change of power to implement blocking for the duration of the swing. In case of shortcircuits during a power swing, the blocking is disabled immediately to allow distance elements to operate. Alternatively an out-of-step tripping feature can be activated which operates either on fast power change or upon detection of instable swings. 1,PP Z Z(t) α 45 α 1 Arc compensation 1: stable power swing 2: instable power swing (out-of-step condition) Tripping Characteristics Power-Swing Characteristic MicoM P432 and P439 for rapid and selective fault clearance in your power system. P432_0837en_QxP.indd 4 11/29/ :02:19 AM
5 05 gound-fault POTeCTiON For the determination of the ground-fault direction in isolated or Peterson-coil compensated power systems two proven methods are provided with P439: wattmetric method (analysis of steady-state signals), with signaling scheme and trip logic; transient method (optional). A highly sensitive zero-sequence power directional protection is integrated as back-up protection in P432 for high-impedance ground short-circuits in lowimpedance grounded systems. In order to achieve high-speed tripping, the device is equipped with a supplementary ground fault (short-circuit) protection signaling logic providing both, a release (permissive) and blocking scheme. This scheme logic can be set up in parallel and independently from the distance scheme logic. POTeCTiON inteface intemicom optional InterMiCOM allows high performance permissive and blocking type unit protection to be configured, plus transfer of any digital status information between line ends. Intertripping is supported too, with channel health monitoring and cyclic redundancy checks (CC) on the received data for maximum message security. InterMiCOM provides eight end-to-end signal bits, assignable to any function within a MiCOM relay s programmable logic. Default failsafe states can be set in case of channel outage. POTeCTive signaling The distance reach is usually set to values below 100 % line length so as to avoid overlapping with adjacent substations. Teleprotection scheme logic extends the reach of protection to 100 % by a logic operation on the signals received from the remote substation. Protective signaling can be operated using one of the standard schemes: Direct Transfer Trip (DTT) Permissive Underreaching Transfer Trip (PUTT) Zone Extension Permissive Overreaching Transfer Trip (POTT) Blocking Scheme (incl. DC loop) everse Interlocking (busbar protection) With P432 phase-selective signal transmission is possible. Where required, additional features as weak infeed trip and echo logic, transient blocking and deblocking can be activated. InformatiON intefaces information exchange is done via the local control panel, the PC interface and two optional communication interfaces. One of the communication interfaces conforms to IEC , IEC , DNP 3.0, Modbus and Courier (IEC in preparation) and is intended for integration with substation control systems. The 2 nd communication interface conforms to IEC and is intended for central settings or remote access. Clock synchronization can be achieved using one of the protocols or using the IIG-B signal input. HMI Full access to all settings, signals and measurands COMM1 SCADA / substation control interface MODEM COMM2 emote access by protection engineer MODEM PC Local access by protection engineer Information Interfaces P432_0837en_QxP.indd 5 11/29/ :02:20 AM
6 06 CONTOl FUNCTiONS The control functions are designed for the control of up to six or 10 resp. electrically operated switchgear units equipped with electrical checkback signaling located in the bay of a mediumvoltage substation or a non-complex high-voltage station. External auxiliary devices are largely obviated through the integration of binary inputs and power outputs that are independent of auxiliary voltages, by the direct connection option for current and voltage transformers and by the comprehensive interlocking capability. For the selection of the bay type the devices are provided with over 250 predefined bay types. These include the assignment of binary inputs and outputs for the switchgear unit control and monitoring and the interlocking logic. Additionally, a customized bay type can be created with bay type configurator BTC and downloaded into the devices. The devices issue switching command outputs with the integration of switching readiness and permissibility tests; subsequently the devices monitor the intermediate position times of the switchgear units. If a switchgear malfunction is detected, this fact will be indicated (e.g. by an appropriately configured LED indicator). The acquisition of further binary inputs is in the form of single-pole operating signals; they are processed in accordance with their significance for the substation (circuit breaker readiness, for example). In addition to the switching command output, a triggering of binary outputs by singlepole commands is possible. Selection of bay type BiNAy COUNTer for the acquisition of a binary count, a binary input may be configured. In the event of loss of operating voltage, the count is stored. Upon the following startup of the unit, counting is continued with the stored value as initial value. Bay type creation with BTC CONTOl AND display From the Local Control Panel all data required for operation of the protection and control unit are entered, the data important for system management are read out and the local control of switchgear units is executed. With the help of the Display Panels, the user is able to carry out a quick and up-to-date check of the state of the bay. On the Bay Panel the selected bay is displayed as a single-pole equivalent network (single line diagram) with the updated switchgear states. Moreover, ancillary information are displayed. Up to 28 status signals are displayed on the Signal Panels which are activated automatically upon status changes. Moreover, presentation modes for the display of status data and status change information can be selected. Selected measured values are displayed on the Measured Value Panels. The type of measured values shown (such as measured operating data or measured fault values) will depend on the prevailing conditions in the substation. The Event Panel displays the most recent events with time-tagging such as the opening of a switchgear unit. Proven control, advanced communication, complete local control, comfortable data handling. P432_0837en_QxP.indd 6 11/29/ :02:22 AM
7 07 Device track record PD 932: first one-box solution for integrated numerical distance protection and control launched in 1998,about 1000 devices installed. MiCOM P439: Transformation of PD 932 into MiCOM range with extended functionality,more than 500 devices installed since MiCOM P432: Combination of MiCOM P439 control with MicoM P437 ehv distance protection, launched in Local Control Panel Bay Bay Panel(s) Signal Panel(s) Measured Value Panel(s) (depending on system condition) Event Panel P439 Page H 17:58:34 P439 Page B 17:58:34 P439 Page A 17:58:34 BB 1 BB2 Q1 Q2 Locked emote Q0 Q A Curr. IP,max prim. MAIN : M.C.B. trip V ET PSS : PS 1 active PSS : PS 2 active MAIN : Bay interlock. act. MAIN : Subst. interl. act. Fault panel 17:58:44 Ground-fault 17:58:44 Overload panel 17:58:44 Meas. values 17:58:44 Voltage A-B prim kv Voltage B-C prim kv Voltage C-A prim kv Current A prim. 416 A Current B prim. 415 A Current C prim. 417 A Events 17:58: :21: AC Enabled Start :58: MAIN CB closed sig. ET End :21: DEV01 Switch.device closed Start Control and Display Panels Device type Parameters Operation Events Device ID Config. parameters Function parameters Cyclic measurements Control and testing Operating data rec. Event counters Measured fault data Event recordings Global General functions Parameter subset 1 Parameter subset... Control Measured operating data Physical state signals Logical state signals Menu Tree Control and Display Panels Schneider Electric 35, rue Joseph Monier CS ueil-malmaison Cedex, France Tel: +33 (0) CS Nanterre Capital social As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper Publishing: Schneider Electric Design: Schneider Electric Printing: 2010 Schneider Electric - All rights reserved EnergyAutomation-DS-P43y-0837-EN P432_0837en_QxP.indd 7 11/29/ :02:23 AM
MiCOM P139. Feeder Management and bay Control. Multifunction IEDs. CustOMEr benefits. APPlICAtIOn
01 Feeder Management and bay Control The is a cost effective one-box solution for integrated numerical time-overcurrent protection and bay control. The broad spectrum of protection functions enables the
Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions
Secure your electrical network The Safety Solution for Healthcare Institutions Fast Secure : the solution for fault isolation and electrical network restoration in less than 500 ms 03 A Real Time System
Transmission Protection Overview
Transmission Protection Overview 2012 Hands-On Relay School Brian Smyth Schweitzer Engineering Laboratories Pullman, WA Transmission Line Protection Objective General knowledge and familiarity with transmission
Feeder protection. for overhead lines and cables in isolated neutral or compensated networks. Specification
Feeder protection for overhead lines and cables in isolated neutral or compensated networks Specification Feeder protection for overhead lines and cables in isolated neutral or compensated networks Version
TDMS Test & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
EVALUATION OF ALTERNATIVE BACKUP PROTECTION SCHEMES ON A 66KV DISTRIBUTION NETWORK
EVALUATION OF ALTERNATIVE BACKUP PROTECTION SCHEMES ON A 66KV DISTRIBUTION NETWORK F. Malone*, P.D. Doyle *ESB International, Ireland [email protected] ESB International, Ireland [email protected]
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Test & Data Management Software
Test & Data Management Software TDMS protective relays energy meters transducers power quality CT-VT-PT transformers ground grid circuit breakers batteries surge arresters The Integrated Testing Solution
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Numerical Differential Protection
Numerical Differential Protection Principles and Applications Publicis Corporate Publishing 1 Introduction 8 1.1 Protection Principle 8 1.2 Numerical Differential Protection 9 2 Deflnitions 10 3 Mode of
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
Maximize protection. MiCOM series 10, 20, 30, 40. Make the most of your energy. Comprehensive range of digital protection relays
Maximize protection MiCOM 10, 20, 30, 40 Comprehensive range of digital protection relays Make the most of your energy Increase energy availability Maximize energy availability and the profits generated
SIPROTEC Protection Technology
SIPROTEC Protection Technology The Basis for Highest Availability of Supply Siemens AG 2012. Siemens All rights reserved. AG 2012 Infrastructure and Cities Objectives of this Brochure Objective The following
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
Relion 611 series. Feeder Protection and Control REF611 Application Manual
Relion 611 series Feeder Protection and Control REF611 Document ID: 1MRS757456 Issued: 2011-11-18 Revision: A Product version: 1.0 Copyright 2011 ABB. All rights reserved Copyright This document and parts
IEC 61850: Communication Networks and Systems in Substations
IEC 61850: Communication Networks and Systems in Substations Sistemi e strumenti per l'automazione, A. Flammini, AA2011-2012 Background I: Power Grid Sistemi e strumenti per l'automazione A. Flammini,
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
Feeder Protection Relay. Technical Reference Manual - ANSI Version
1MRS755535 Issued: 30.01.2005 Version: E/18.11.2011 Contents Copyrights... 7 1. Introduction...9 1.1. This manual... 9 1.2. Use of symbols... 9 1.3. Intended audience... 9 1.4. Product documentation...
Local Back-up Protection for an Electric Power System
MULTILIN GER-3178 GE Power Management Local Back-up Protection for an Electric Power System LOCAL BACK UP PROTECTION FOR AN ELECTRIC POWER SYSTEM J. BERDY TABLE OF CONTENTS Transmission Line Back-Up Protection...............................................
Technical Specification Of Substation Protection & Control System with IEC 61850 BHEL s Perspective
Technical Specification Of Substation Protection & Control System with IEC 61850 BHEL s Perspective India Core Events 2008 September 24 th 2008 1 Background Stability & Reliability Data Storage Communication
Wide Area Monitoring Current Continental Europe TSOs Applications Overview
Wide Area Monitoring Current Continental Europe TSOs Applications Overview Version 5 System Protection & Dynamics Working Group 20th September 2015 1. Content 1. Content... 2 2. Introduction... 3 3. Main
Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template
Application Note Application-oriented testing of line differential protection end to end in the field using the corresponding RelaySimTest template Author Jens Baumeister [email protected] Date
Electric utilities may vary in their application of end-to-end testing
An Application Case of End-to-End Relay Testing of Communication-Based Protection Schemes Using GPS-Synchronized Secondary Injection Feature by J. Ariza, Megger USA G. Ibarra, CFE, Mexico Electric utilities
Protection and Substation Automation. Training Programmes
Protection and Substation Automation Training Programmes Protection and Substation Automation Training Programme Overview The objective of the Training Program is to provide education and training to make
APPLICATION CASE OF THE END-TO-END RELAY TESTING USING GPS-SYNCHRONIZED SECONDARY INJECTION IN COMMUNICATION BASED PROTECTION SCHEMES
APPLICATION CASE OF THE END-TO-END RELAY TESTING USING GPS-SYNCHRONIZED SECONDARY INJECTION IN COMMUNICATION BASED PROTECTION SCHEMES J. Ariza G. Ibarra Megger, USA CFE, Mexico Abstract This paper reviews
Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation
Medium Voltage (MV) & High Voltage (HV) Training Module 6 Date of the presentation Electrical System Basics MV vs. HV - Definitions Differences between USA and the rest of the world IEC define a high voltage
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)
24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
Arc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
Nu-Lec Training Modules
PTCC Controller Nu-Lec Training Modules Product Training Operator Training PTCC The Basics An overview of the construction and physical features of the Pole Top Control Cubicle PTCC Operation and Features
MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING
Training Title MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING Training Duration 5 days Training Date MV, HV and EHV Switchgear Testing & Commissioning 5 20 24 Apr $3,750 Dubai, UAE In any of the 5 star
Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850
Relion Power system protection and automation reference Extending substation life cycle with IEC 61850 Extending substation life cycle with IEC 61850 A step-by-step power system retrofit approach for optimizing
How To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
How To Protect Your Power Supply From Dangerous Currents And Voltages
ids ACOS 300 Protection equipment for medium and highvoltage grids ACOS 300 Protection Devices Already minor incidents, such as branches dropping on overhead lines or underground cables damaged by construction
TA Kahraman Yumak ELK412 - Distribution of Electrical Energy Lab. Notes v1.0 2013 Spring web.itu.edu.tr/yumakk. Distance Protection
Distance Protection Announcement: You are not supposed to prepare a pre-report. But there will be an oral examination, so you are strongly advised to study this note regarding to the pre-study questions
Power network telecommunication
www.siemens.com Power network telecommunication Teleprotection Answers for infrastructure and cities. Binary I/O The best protection against high-voltage grid failures When it comes to managing power networks,
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring
Siemens Integrated Substation Condition Monitoring System Circuit Breaker Monitoring System Description Introduction The Circuit Breaker Monitor [CBM] is only one example of the way that the Substation
GE Protection and Control Business Department. Page 1 Date 5/11/99
GE Protection and Control Business Department Page 1 GE Protection and Control Business Department Proven Overcurrent Protection with Power Management Communication The The Advantages of Microprocessor
30 ms High Speed Transfer System (HSTS) Product Description
30 ms High Speed Transfer System (HSTS) Product Description 2 30 ms High Speed Transfer System (HSTS) Product Description Content Page 1 General 5 1.1 Description of the 30 ms high speed transfer system
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
SENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
Catalog. Arc Guard System TM TVOC-2
Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already
Teleprotection Schemes and Equipment. James W. Ebrecht Young Power Equipment Scottsdale, AZ
* Teleprotection Schemes and Equipment James W. Ebrecht Young Power Equipment Scottsdale, AZ Teleprotection Schemes And Equipment ~ ~ Relay Relay Teleprotection Communications channel Teleprotection Protection
ECE 586b Course Project Report. Auto-Reclosing
ECE 586b Course Project Report Auto-Reclosing Srichand Injeti May 5, 2008 Department Of Electrical and computer Engineering University Of Western Ontario, London Ontario Table of contents 1. Introduction...1
The Application and Benefits of Multi-phase Auto-reclosing
he Application and Benefits of Multi-phase Auto-reclosing etsuya Miyoshi*, Atsushi Kasai* Abstract - In this paper we explain the disadvantages in using single- and three-phase auto-reclosing on double
Part 1 System Modeling & Studies for Existing Systems
Part 1 System Modeling & Studies for Existing Systems Operation Technology, Inc. Copyright 2009 Result of rapid release of energy due to an arcing fault between two conductors. Bus voltages > 208V Temperatures
IEC 61850 in ZX Gas-insulated medium voltage switchgear
IEC 61850 in ZX Gas-insulated medium voltage switchgear IEC 61850 in ZX Just as the supply of electrical power is becoming more and more important in a networked world, demands for the integration of electrical
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Substation Automation Systems. Nicholas Honeth ([email protected])
Substation Automation Systems Nicholas Honeth ([email protected]) Contents of the series Lecture 5 - Introduction to SAS - Nice creative exercise Lecture 6 - A bit about information modelling - Data
Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements
Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements - Two (2) MiCOM Px4x IEDs with Version 2 implementation of IEC 61850 - Two (2) Cat 5E Ethernet cable - An Ethernet switch 10/100 Mbps - MiCOM
Industrial IT for Substation Automation & Protection
Industrial IT for Substation Automation & Protection Exploit the potential of ABB substation automation Improve your performance In view of the increasingly competitive arena where power providers are
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.
Generation Interconnection System Impact Study Report For PJM Generation Interconnection Request Queue Position X1-114 Sandyston January 2012 Preface The intent of the System Impact Study is to determine
Numerical transformer protection in medium voltage networks Transformer Protection and Control RET620
Guideform Specification 1MRS758531 A Numerical transformer protection in medium voltage networks Transformer Protection and Control RET620 The configurable transformer management relay is intended for
Transmissão em Corrente Contínua
Transmissão em Corrente Contínua Panorama Atual e Perspectivas Futuras no Brasil Multi-Terminal HVDC Classic Some Considerations Brazilian SC B4 Paulo Fischer de Toledo, ABB Basic considerations Traditional
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Easily connect your switchboards to facility management solutions
Easily connect your switchboards to facility management solutions Acti 9 communication system gives your customers complete control of their installations 100% exclusive to Schneider Electric Acti 9: The
High EMI immunity. I/O events are timestamped locally on each module.
%,0%20,20 360 Page 1 Revision: - Issued: November 2002 Data subject to change without notice )HDWXUHV $SSOLFDWLRQ &RPPRQ High EMI immunity. I/O events are timestamped locally on each module. %LQDU\LQSXWV
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Earth Fault Detection Basics in Theory
Earth Fault Detection Basics in Theory Author: Dipl.-Ing. Ingo Kühnen Woodward Power Solutions Krefelder Weg 47 47906 Kempen, Germany Kempen, 16.04.2010 Earth_Fault_Detection_20100416.doc page 1 1. Star
ENERGY: MODULAR POWER SYSTEM SIMULATOR. BASIC MODULE
issue:01/11 ENERGY: MODULAR POWER SYSTEM SIMULATOR. BASIC MODULE Ref: 0510 1 / 2 ITEM REFERENCE DESCRIPTION QTY. 1 MPSSC MODULAR POWER SYSTEM SIMULATOR WITH SCADA 1 CONTROL SYSTEM, FORMED BY: SCADA SCADA
Relion 605 series. Feeder protection and control / Feeder protection REF601 / REJ601 Product Guide
Relion 605 series Feeder protection and control / Feeder protection Product Guide Product version: 2.2FP1 Contents 1. Description... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...
Monitoring & Control of Small-scale Renewable Energy Sources
Small Scale Renewable Energy Sources and Energy Saving: 6-17 th July 2009 Monitoring & Control of Small-scale Renewable Energy Sources Dr G A Taylor Brunel Institute of Power Systems Brunel University,
Managing Relion IEDs Protection and control IED manager PCM600
Managing Relion IEDs Protection and control IED manager PCM600 Efficient management of Relion protection and control IEDs The protection and control IED manager PCM600 tool provides versatile functionalities
Relion 605 series. Self-powered feeder protection REJ603 Product Guide
Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...
Products and solutions for pumping, irrigation and piping
Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric
Chapter 1. Network Structures
Chapter 1 Network Structures Definition Standard IEC 60038 defines voltage ratings as follows: Low voltage (): for a phase-to-phase voltage of between 100 V and 1,000 V, the standard ratings are: 400 V
Distribution Automation Handbook. Section 8.13 Backup Protection
Distribution Automation Handbook Section 8.13 Backup Protection 2 Contents 8.13 Backup Protection... 3 8.13.1 Introduction... 3 8.13.1.1 REQUIREMETS FOR BACKUP PROTECTIO... 3 8.13.1.2 JUSTIFICATIO OF RESERVE
New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System for Low Voltage Distribution Systems
International Conference on Computer and Communication Engineering (ICCCE 2010), 11-13 May 2010, Kuala Lumpur, Malaysia New Supervisory Control and Data Acquisition (SCADA) Based Fault Isolation System
Evaluation of L-PRO 4000 for End-to-End Communication Using IEC 61850 Protocol With RFL IMUX 2000 Multiplexer
Evaluation of L-PRO 4000 for End-to-End Communication Using IEC 61850 Protocol With RFL IMUX 2000 Multiplexer Introduction The ERLPhase L-PRO 4000 Transmission Line Protection Relay provides standard communication-aided
F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China
ELECTRIC POWER DISTRIBUTION SYSTEMS F.C. Chan General Manager, CLP Engineering Ltd., Hong Kong SAR, China Keywords: Distribution system planning, Load characteristics, Subtransmission Lines, Distribution
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks
SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1
Comprehensive Range of Industrial Products and Solutions
Comprehensive Range of Industrial Products and Solutions SAFETY AUTOMATION Micro Controllers Small Controllers Mid Range Controllers Large Automation Controllers Safety Programmable Controller Motion Controller
ABB North America. Substation Automation Systems Innovative solutions for reliable and optimized power delivery
ABB North America Substation Automation Systems Innovative solutions for reliable and optimized power delivery Substation Automation Systems Advanced substation automation, protection and control solutions
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services
Relion 611 series. Feeder Protection and Control REF611 Modbus Point List Manual
Relion 611 series Feeder Protection and Control REF611 Modbus Document ID: 1MRS757463 Issued: 2011-11-18 Revision: A Product version: 1.0 Copyright 2011 ABB. All rights reserved Copyright This document
Executive Summary. Technical Description
Executive Summary The Cellwatch system is built using modules. The majority of the system is constructed with Data Collection Modules (DCMs). The DCMs are optically linked to Control Units (CUs) that in
An Alternative Approach to Improving SAIDI and SAIFI Indicators
An Alternative Approach to Improving SAIDI and SAIFI Indicators Philippe Deschamps - Schneider Electric Industries - France Jean-Christophe Orsini - Schneider Electric Industries - France Kaare Seest Rasmussen
INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012
INTRODUCTION TO SYSTEM PROTECTION Hands-On Relay School 2012 CONGRATULATIONS On choosing the field of system protection. It is an exciting, challenging profession. System protection has changed considerably
CSP1-L Cable and Line Differential Protection System Performance and functional outline
SYSTEM LINE CSP1-L Cable and Line Differential Protection System Performance and functional outline SCADA RS 232 Operation and display via Notebook Operation and display via CMP1 CAN-BUS FO FO RS 232 (in
E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays E-Series protective relay family Reliable protection for every application Eaton s E-Series relay
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
Relion 615 series. Transformer Protection and Control RET615 Product Guide
Relion 615 series Transformer Protection and Control Product Guide Contents 1. Description... 3 2. Standard configurations... 3 3. Protection functions...14 4. Application... 15 5. Supported ABB solutions...
SIPROTEC 4 7SD5 Multi-End Differential and Distance Protection in One Relay
Line Differential Protection / SD5 SIPROTEC 4 SD5 Multi-End Differential and Distance Protection in One Relay Function overview LSP213f.eps Fig. /3 SIPROTEC 4 SD5 differential protection relay Description
Documentation. M-Bus 130-mbx
Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
Paralleling Switchgear
Paralleling Switchgear By Maurice D Mello, P.Eng. Systems Engineer, GE Consumer & Industrial, Canada What is Paralleling? Paralleling is the operation in which multiple power sources, usually two or more
Everything you need for protection scheme testing
Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full