Cable & Wire Management
|
|
|
- Leo Pierce Jones
- 10 years ago
- Views:
Transcription
1 able & ire Management able & ire Management Lay-In ireway Type 1 Screw over Lay-In ireway Type 1 Quick-onnect inge over Lay-In ireway Type 3R EnviroShield Lay-In ireway Type Feed-Through ireway Type Feed-Through ireway Type 4X iring Trough Type 1 Screw over iring Trough Type 3R Screw over iring Trough Type 12 Lift-Off over iring Trough Type 4X Lift-Off over Line series electrical enclosures 7
2 able & ire Management able & ire Management Lay-In ireway Type 1 Screw over - Painted & Galvanized ata Sheet pplication ouses runs of control and power cable Used for cable and wire junction, distribution and termination Standards UL 870 listed, Type 1 S 22.2 No. 26 certified, Type 1 onforms to NEM standard for Type 1 Finish ash and phosphate undercoat or galvanized steel NSI 61 gray acrylic electrocoat finish ccessories Sealing devices Touch-up paint See ccessories section onstruction ireway body and cover are fabricated from code gauge steel or galvanized steel, (see table, pages 9 & 10) ireway body has mounting holes on the back ireway is available with or without knockouts ireway fittings have no knockouts, ends are available with or without knockouts over is secured to the body with plated screws Keyhole slots are furnished on the wireway cover which allow easy access to the inside without removing the screws ireway exceeding 72 inches in length has two overlapping covers Variety of fittings allow runs which can change direction, junction and terminate Standard wireway connectors (sold separately) have a gate feature which can swing completely open allowing for lay-in of wire and cable Interchangeable with Type 1 inge over ireway and Fittings when S connector is used, (see page 17) iscount Schedule: 2 Subclass: K1 & Z40 Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 8 -Line series electrical enclosures
3 able & ire Management Lay-In ireway Type 1 Screw over - Painted & Galvanized atalog Number ireway atalog Number ireway Size Knockout Quantity Painted Galvanized eight x epth x Length x x KO No KO KO No KO in. mm in. mm Gauge Top ottom 2212 G 2212 G NK GGV NK 2.50 x 2.50 x x 64 x G 2224 G NK 2224 GGV 2224 GGV NK 2.50 x 2.50 x x 64 x G 2236 G NK 2236 GGV 2236 GGV NK 2.50 x 2.50 x x 64 x G 2248 G NK GGV NK 2.50 x 2.50 x x 64 x G 2260 G NK 2260 GGV 2260 GGV NK 2.50 x 2.50 x x 64 x G G NK GGV GGV NK 2.50 x 2.50 x x 64 x G NK x 3.00 x x 76 x G NK x 3.00 x x 76 x G NK x 3.00 x x 76 x G NK x 3.00 x x 76 x G NK x 3.00 x x 76 x G NK x 3.00 x x 76 x G NK x 3.00 x x 76 x G 4412 G NK 4412 GGV 4412 GGV NK 4.00 x 4.00 x x 102 x G 4418 G NK GGV NK 4.00 x 4.00 x x 102 x G 4424 G NK 4424 GGV 4424 GGV NK 4.00 x 4.00 x x 102 x G 4436 G NK 4436 GGV 4436 GGV NK 4.00 x 4.00 x x 102 x G 4448 G NK 4448 GGV 4448 GGV NK 4.00 x 4.00 x x 102 x G 4460 G NK 4460 GGV 4460 GGV NK 4.00 x 4.00 x x 102 x G 4472 G NK 4472 GGV 4472 GGV NK 4.00 x 4.00 x x 102 x G G NK GGV GGV NK 4.00 x 4.00 x x 102 x G NK x 4.00 x x 102 x G NK x 4.00 x x 102 x G NK x 4.00 x x 102 x G NK x 4.00 x x 102 x G NK x 4.00 x x 102 x G NK x 4.00 x x 102 x G NK x 4.00 x x 102 x G NK x 4.00 x x 102 x G 6612 G NK 6612 GGV 6612 GGV NK 6.00 x 6.00 x x 152 x G 6618 G NK GGV NK 6.00 x 6.00 x x 152 x G 6624 G NK 6624 GGV 6624 GGV NK 6.00 x 6.00 x x 152 x G 6636 G NK 6636 GGV 6636 GGV NK 6.00 x 6.00 x x 152 x G 6648 G NK 6648 GGV 6648 GGV NK 6.00 x 6.00 x x 152 x G 6660 G NK 6660 GGV 6660 GGV NK 6.00 x 6.00 x x 152 x G 6672 G NK 6672 GGV 6672 GGV NK 6.00 x 6.00 x x 152 x G G NK GGV GGV NK 6.00 x 6.00 x x 152 x G 8812 G NK 8812 GGV 8812 GGV NK 8.00 x 8.00 x x 203 x G 8818 G NK GGV NK 8.00 x 8.00 x x 203 x G 8824 G NK 8824 GGV 8824 GGV NK 8.00 x 8.00 x x 203 x G 8836 G NK 8836 GGV 8836 GGV NK 8.00 x 8.00 x x 203 x G 8848 G NK 8848 GGV 8848 GGV NK 8.00 x 8.00 x x 203 x G 8860 G NK 8860 GGV 8860 GGV NK 8.00 x 8.00 x x 203 x G 8872 G NK 8872 GGV 8872 GGV NK 8.00 x 8.00 x x 203 x G G NK GGV GGV NK 8.00 x 8.00 x x 203 x able & ire Management See page 10 for 10 x10 and 12 x12 wireway. -Line series electrical enclosures 9
4 able & ire Management able & ire Management Lay-In ireway Type 1 Screw over - Painted & Galvanized Illustration Sheet and atalog Number ireway atalog Number ireway Size Knockout Quantity Painted Galvanized eight x epth x Length x x KO No KO KO No KO in. mm in. mm Gauge Top ottom G G NK GGV NK x x x 254 x G G NK GGV NK x x x 254 x G G NK GGV NK x x x 254 x G G NK GGV NK x x x 254 x G G NK GGV NK x x x 254 x G G NK GGV NK x x x 254 x G G NK GGV NK x x x 254 x G G NK GGV NK x x x 305 x G G NK GGV NK x x x 305 x G G NK GGV NK x x x 305 x G G NK GGV NK x x x 305 x G G NK GGV NK x x x 305 x G G NK GGV NK x x x 305 x G G NK GGV NK x x x 305 x (102) ireway Section Lengths from (305 mm) to (3048 mm). ireway exceeding (1829 mm) has two covers. Shown with KO s, also available without. cover screw ireway over mounting hole 1.25 (32) 1.56 (40) J J J Knockout sizes: = 3 /4 or 1 /2 conduit J = 1 1 /4 or 1 conduit 3.00 (76) 3.00 (76) typ. spacing 3.00 (76) typ. spacing ireway Side Note: 2.50 x 2.50 wireway has 1 /2 and 3 /4 2-way knockouts only, 3 (76 mm) from ends and 3 (76 mm) on center. dditional mounting holes are furnished when dimension is over 60.00" (1524 mm). 10 -Line series electrical enclosures
5 able & ire Management Lay-In ireway Type 1 Screw over - Painted & Galvanized Illustration Sheet and atalog Number 2 1 Telescopic Fitting djustable length up to (254 mm). raps around the two near joining wireway lengths to achieve a continuous run. Telescopic Fitting atalog Number 1 2 Painted Galvanized in. mm in. mm in. mm in. mm 22 FTF 22 FTFGV FTF FTF 44 FTFGV FTF FTF 66 FTFGV FTF 88 FTFGV FTF 1010 FTFGV FTF 1212 FTFGV End Used to terminate wireway or fitting x 2.50 (64 mm x 64 mm) through 8.00 x 8.00 (203 mm x 203 mm) ends have a concentric 2-way KO x (254 mm x 254 mm) ends and larger have a concentric 2-way KO for terminating on pipe or conduit. lso available without KO. End atalog Number Painted Galvanized KO No KO KO No KO in. mm in. mm 22 E 22 E NK 22 EGV 22 EGV NK E 33 E NK E 44 E NK 44 EGV 44 EGV NK E 64 E NK E 66 E NK 66 EGV 66 EGV NK E 88 E NK 88 EGV 88 EGV NK E 1010 E NK 1010 EGV 1010 EGV NK E 1212 E NK 1212 EGV 1212 EGV NK See drawing for KO sizes. able & ire Management E F ireway End Flange llows for a secure connection of wireway to an adjoining enclosure or wall. onnector Swing gate allows for lay-in of wire and cable. ireway End Flange atalog Number E F Painted Galvanized in. mm in. mm in. mm in. mm 22 GF 22 GFGV GF GF 44 GFGV GF GF 66 GFGV GF 88 GFGV GF 1010 GFGV GF 1212 GFGV onnector atalog Number in. mm in. mm Line series electrical enclosures 11
6 able & ire Management able & ire Management Lay-In ireway Type 1 Screw over - Painted & Galvanized Illustration Sheet and atalog Number Reducer dimensions (see catalog table), correspond to the large end opening. Used to reduce or enlarge wireway runs. J Reducer atalog Number Painted Galvanized in. mm in. mm in. mm 2233 FR FR FR FR FR FR K ireway angers ireway anger atalog Number G J K Painted Galvanized in. mm in. mm in. mm in. mm 22 F F F F F F* F* *angers are shipped welded in the top cover assembly position. (shipped unassembled)* Side over ssembly For those installations where the wireway cover must be removed from the side. G K Top over ssembly For those installations where the wireway cover must be removed from the top. G.875 (22) (1524).875 (22) arrier, olt-on For those installations that require separated wiring compartments. arrier Kit, 60 olt-on atalog Number Size Length in. mm in. mm in. mm 22-12K* 2.50 x x K* 3.00 x x K* 4.00 x x K* 6.00 x x K* 8.00 x x K* x x K* x x *Not UL or S listed fitting. 90 Elbow-Tee-ross esigned for left or right 90 turns or as a tee or cross by removing closure plates. Includes two (2) closure plates and hardware. 90 Elbow - Tee - ross atalog Number Painted Galvanized in. mm in. mm in. mm 22 LTX 22 LTXGV LTX LTX 44 LTXGV LTX LTX 66 LTXGV LTX 88 LTXGV LTX 1010 LTXGV LTX 1212 LTXGV Line series electrical enclosures
7 Lay-In ireway Type 1 - Painted & Galvanized Illustration Sheet and atalog Number ireway 90 Elbows Screw over E Side Opening Side cover is removable to allow a continuous run on designs with 90 turns. F ombo Opening Specially designed for removing either the inside or outside cover to allow a continuous run with 90 turns. Sweep Elbow Side cover design with a larger radius for 90 sweeping turns. able & ire Management 90 Elbow - Screw over atalog Number E F Painted Galvanized in. mm in. mm in. mm in. mm in. mm 22 L OMO 22 L OMOGV L OMO L OMO 44 L OMOGV L OMO L OMO 66 L OMOGV L OMO 88 L OMOGV L OMO 1010 L OMOGV L OMO 1212 L OMOGV L SIE L SIE L SIE L SIE L SIE L SIE L SIE L SIE L SEEP 22 L SEEPGV L SEEP L SEEP 44 L SEEPGV L SEEP L SEEP 66 L SEEPGV L SEEP 88 L SEEPGV L SEEP 1010 L SEEPGV L SEEP 1212 L SEEPGV able & ire Management ireway 90 Elbows inged over Outside Opening Specifically designed to have the outside covers hinge open to allow a continuous run with 90 turns. Side Opening Side cover is hinged to allow a continuous run on designs with 90 sweeping turns. Inside Opening Specifically designed to have only the inside cover hinge open to allow a continuous run with 90 turns. 90 Elbow - inged over atalog Number E F Painted in. mm in. mm in. mm in. mm 33 FL IN FL IN FL IN FL IN FL IN FL IN FL OUT FL OUT FL OUT FL OUT FL OUT FL OUT FL SIE FL SIE FL SIE FL SIE FL SIE FL SIE Line series electrical enclosures 13
8 able & ire Management able & ire Management Lay-In ireway Type 1 Screw over - Painted & Galvanized Illustration Sheet and atalog Number ireway 45 Elbows ombo Opening Similar to the 90 elbow design except a 45 turn. oth inside and outside covers removable. E Side Opening Similar to the 90 side opening design except for a 45 turn. Excellent for combining two to make a gradual sweeping 90 turn. F 45 Elbow atalog Number E F Painted Galvanized in. mm in. mm in. mm in. mm 2245 L OMO 2245 L OMOGV L OMO L OMO 4445 L OMOGV L OMO L OMO 6645 L OMOGV L OMO 8845 L OMOGV L OMO L OMOGV L OMO L OMOGV L SIE L SIE L SIE L SIE L SIE L SIE L SIE L SIE Tee Side cover design where a T junction is necessary. E F F Tee atalog Number E F Painted Galvanized in. mm in. mm in. mm in. mm 22 T 22 TGV T T 44 TGV T T 66 TGV T 88 TGV T 1010 TGV T 1212 TGV ross Side cover and broad body design to junction cable run in four directions. E E.75 (19) ross atalog Number E F Painted Galvanized in. mm in. mm in. mm in. mm 22 X 22 XGV X X 44 XGV X X 66 XGV X 88 XGV X 1010 XGV X 1212 XGV F F.75 (19) 14 -Line series electrical enclosures
9 able & ire Management Lay-In ireway Type 1 Quick-onnect inge over ata Sheet able & ire Management Reversible and removable hinge cover Pre-installed hardware on quick connector pplication ouses runs of control and power cable Used for cable and wire junction, distribution and termination Standards UL 870 listed, Type 1 S 22.2 No. 26 certified, Type 1 onforms to NEM standard for Type 1 Finish ash and phosphate undercoat NSI 61 gray acrylic electrocoat finish ccessories Touch-up paint See ccessories section Protected by U.S. Patents 7,525,044 & 7,762,042 onstruction ireway body and cover are fabricated from code gauge steel, (see table, page 16) ireway body has mounting holes on the back ireway is available with or without knockouts ireway fittings have no knockouts, ends are available with or without knockouts ireway exceeding 72 inches in length has two overlapping covers Variety of fittings allow runs which can change directions, junction and terminate ireway connectors (sold separately) have a gate feature which can swing completely open allowing for lay-in of wire and cable Universal style connectors are also available for adapting to other manufacturer s wireway, (see page 17) Except for wireway ends, completely interchangeable with Type 1 screw cover wireway and fittings through use of the adapter style connector S, (see page 17) iscount Schedule: 2 Subclass: S1 Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. -Line series electrical enclosures 15
10 able & ire Management able & ire Management Lay-In ireway Type 1 Quick-onnect inge over Illustration Sheet and atalog Number ireway ireway Size Knockout atalog Number eight x epth x Length Quantity x x KO No KO in. mm in. mm Gauge Top ottom 2212 S 2212 S NK 2.50 x 2.50 x x 63 x S 2224 S NK 2.50 x 2.50 x x 63 x S 2236 S NK 2.50 x 2.50 x x 63 x S 2248 S NK 2.50 x 2.50 x x 63 x S 2260 S NK 2.50 x 2.50 x x 63 x S 2272 S NK 2.50 x 2.50 x x 63 x S S NK 2.50 x 2.50 x x 63 x S 4412 S NK 4.00 x 4.00 x x 102 x S 4424 S NK 4.00x x 4.00 x x 102 x S 4436 S NK 4.00 x 4.00 x x 102 x S 4448 S NK 4.00 x 4.00 x x 102 x S 4460 S NK 4.00 x 4.00 x x 102 x S 4472 S NK 4.00 x 4.00 x x 102 x S S NK 4.00 x 4.00 x x 102 x S 6612 S NK 6.00 x 6.00 x x 152 x S 6624 S NK 6.00 x 6.00 x x 152 x S 6636 S NK 6.00 x 6.00 x x 152 x S 6648 S NK 6.00 x 6.00 x x 152 x S 6660 S NK 6.00 x 6.00 x x 152 x S 6672 S NK 6.00 x 6.00 x x 152 x S S NK 6.00 x 6.00 x x 152 x S 8812 S NK 8.00 x 8.00 x x 203 x S 8824 S NK 8.00 x 8.00 x x 203 x S 8836 S NK 8.00 x 8.00 x x 203 x S 8848 S NK 8.00 x 8.00 x x 203 x S 8860 S NK 8.00 x 8.00 x x 203 x S 8872 S NK 8.00 x 8.00 x x 203 x S S NK 8.00 x 8.00 x x 203 x S S NK x x x 254 x S S NK x x x 254 x S S NK x x x 254 x S S NK x x x 254 x S S NK x x x 254 x S S NK x x x 254 x S S NK x x x 305 x S S NK x x x 305 x S S NK x x x 305 x S S NK x x x 305 x S S NK x x x 305 x S S NK x x x 305 x ireway over cover screw mounting hole ireway Section Lengths from (305 mm) to (305 mm). ireway exceeding (1829 mm) has two covers. Shown with KO's, also available without J J J J Knockout sizes: = 3 /4 or 1 /2 conduit J = 1 1 /4 or 1 conduit typ. spacing 3.00 typ. spacing ireway Side Notes: dditional mounting holes are furnished when dimension is over 60.00" (1524 mm). imensions are in inches. Millimeters shown are for reference only. ata subject to change without notice. 16 -Line series electrical enclosures
11 able & ire Management Lay-In ireway Type 1 Quick-onnect inge over Illustration Sheet and atalog Number 1 Telescopic Fitting djustable length up to (254 mm). raps around the two near joining wireway lengths to achieve a continuous run. Reducer dimensions (see catalog table), correspond to the large end opening. Used to reduce or enlarge wireway runs. Removable cover is secured with screws. able & ire Management 2 Telescopic Fitting atalog Number 1 2 in. mm in. mm in. mm in. mm 22 FTF FTF FTF FTF FTF FTF FTF Reducer atalog Number in. mm in. mm in. mm 2233 FR * FR * FR * FR * FR * FR * * Requires use of S dapter Style onnector. onnector Style dapter Style Universal Style onnector Swing gate allows for lay-in of wire and cable. End Used to terminate wireway or fitting. Shown with KO, also available without. rawing shows screws in place. Screws are actually packaged in plastic bags. onnector atalog Number onnector Style dapter Style Universal Style in. mm in. mm 22 S 22 S 22 SU S 44 S 44 SU S 66 S 66 SU S 88 S 88 SU S 1010 S 1010 SU S 1212 S 1212 SU S - Standard Quick onnector S - For adapting to Type 1 Screw over ireway SU - For adapting to competitive ireway End atalog Number KO KO No KO in. mm in. mm in. mm 22 SE 22 SE NK SE 44 SE NK SE 66 SE NK SE 88 SE NK SE 1010 SE NK SE 1212 SE NK Line series electrical enclosures 17
12 able & ire Management able & ire Management Lay-In ireway Type 1 Quick-onnect inge over Illustration Sheet and atalog Number E F ireway End Flange llows for a secure connection of wireway to an adjoining enclosure or wall. K G ireway angers K G J (shipped unassembled) ireway End Flange atalog Number E F in. mm in. mm in. mm in. mm 22 SF SF SF SF SF SF (1524) Side over ssembly For those installations where the wireway cover must be hinged at the side. Top over ssembly For those installations where the wireway cover must be hinged at the top. ireway anger atalog Number G J K in. mm in. mm in. mm in. mm 22 F F F F F ** F ** **angers are shipped welded in the top cover assembly position..875 (22).875 (22) arrier, olt-on For those installations that require separate wiring compartments. arrier Kit, 60 olt-on atalog Number Size Length in. mm in. mm in. mm 22-12K* 2.50 x x K* 3.00 x x K* 4.00 x x K* 6.00 x x K* 8.00 x x K* x x K* x x *Not UL or S listed fitting. 18 -Line series electrical enclosures
13 Lay-In ireway Type 1 Quick-onnect inge over Illustration Sheet and atalog Number ireway 90 Elbows Inside Opening Specifically designed to have only the inside cover hinge open to allow a continuous run with 90 turns. Side Opening Side cover is hinged to allow a continuous run on designs with 90 sweeping turns. able & ire Management 90 Elbow atalog Number E F in. mm in. mm in. mm in. mm 22 SL IN SL IN SL IN SL IN SL IN SL IN SL OUT SL OUT SL OUT SL OUT SL OUT SL OUT SL SIE SL SIE SL SIE SL SIE SL SIE SL SIE able & ire Management Outside Opening Specifically designed to have the outside covers hinge open to allow a continuous run with 90 turns. E F.75 (outside opening) (19) F (inside and side opening) E.75 (19) ombo Opening esigned to achieve a 45 turn. Inside and outside removable covers are secured with screws. ireway 45 Elbows Side Opening esigned to achieve a 45 turn and have the cover removed from the side. Excellent for combining two to make a gradual 90 sweep. 45 Elbow atalog Number E F in. mm in. mm in. mm in. mm 2245 SL OMO SL OMO SL OMO SL OMO SL OMO SL OMO SL SIE SL SIE SL SIE SL SIE SL SIE SL SIE E F -Line series electrical enclosures 19
14 able & ire Management able & ire Management Lay-In ireway Type 1 Quick-onnect inge over Illustration Sheet and atalog Number Tee Side hinge cover design for applications where a T junction is necessary. Tee atalog Number E F in. mm in. mm in. mm in. mm 22 ST ST ST ST ST ST E.75 (19) F F.75 (19) ross Side cover and broad body design to junction cable run in four directions. Removable cover is secured with screws. ross atalog Number E F in. mm in. mm in. mm in. mm.75 (19) 22 SX SX SX SX SX SX E E F F.75 (19) 20 -Line series electrical enclosures
15 able & ire Management Lay-In ireway Type 3R EnviroShield System ata Sheet able & ire Management Install inside connector in wireway ends and tighten Install and secure hinged covers Install outside connector around wireway splice location Latch shut (padlock can be installed if desired) pplication ouses runs of power, control and communication cable Used for cable and wire junction, distribution and termination Standards UL 870 listed, Type 3R S 22.2 No. 26 certified, Type 3R onforms to NEM standard for Type 3R Material & Finish Galvanealed steel with NSI 61 gray acrylic electrocoat finish and zinc plated hardware luminum with stainless steel hardware ccessories Sealing devices Touch-up paint See ccessories section onstruction ireway body and cover are fabricated from code gauge steel, or brushed aluminum (see page 22) ireway body has embossed mounting holes on the back over is secured to the body with gasketed retaining screw Variety of fittings allow runs which can change directions, size, junction and terminate, as well as, expansion and contraction ireway connectors (sold separately) have a gate feature which can swing completely open allowing for lay-in of wire and cable ireway connectors have a locking feature for optional pad-locking Removable hinge cover construction Z-slots for quick-connect connection method ireways 120 (3048mm) in length have two overlapping covers iscount Schedule: 2 Subclass: RS Protected by U.S. Patents 7,525,044 & 7,762,042 Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. -Line series electrical enclosures 21
16 able & ire Management able & ire Management Lay-In ireway Type 3R EnviroShield System Illustration Sheet and atalog Number ireway Section Lengths from to ireway exceeding has two covers. over Screw ireway Side L L L ireway ottom Mounting Embossment with.25 ia. ole (4) ireway ireway Size Mounting Material atalog Number eight x epth x Length ole Spacing Thickness Steel luminum x x Steel luminum in. mm in. mm Gauge mm In. mm RS NK RS NK 4.00 x 4.00 x x 101 x RS NK RS NK 4.00 x 4.00 x x 101 x RS NK RS NK 4.00 x 4.00 x x 101 x RS NK RS NK 6.00 x 6.00 x x 152 x RS NK RS NK 6.00 x 6.00 x x 152 x RS NK RS NK 6.00 x 6.00 x x 152 x RS NK RS NK 8.00 x 8.00 x x 203 x RS NK RS NK 8.00 x 8.00 x x 203 x RS NK RS NK 8.00 x 8.00 x x 203 x NK = No Knockouts ireway onnectors Swing gate allows for lay-in installation of wire and cable. rap-around connector provides Type 3R rating and padlocking provision. 3.0 onnector Screw learance oles onnector atalog Number Steel luminum in. mm in. mm 44-3RS 44-3RS RS 66-3RS RS 88-3RS Padlockable Latch 22 -Line series electrical enclosures
17 able & ire Management Lay-In ireway Type 3R EnviroShield System Illustration Sheet and atalog Number ireway End Used to terminate wireway or fitting. ireway End atalog Number Steel luminum in. mm in. mm able & ire Management 44-3RSE NK 44-3RSE NK RSE NK 66-3RSE NK RSE NK 88-3RSE NK ireway End Flange llows for a secure connection of wireway or fitting to an adjoining enclosure or wall. ireway End Flange atalog Number Steel luminum in. mm in. mm 44-3RSF 44-3RSF RSF 66-3RSF RSF 88-3RSF ireway 90 Elbow Side opening hinge cover design for applications where 90 turn is necessary. ireway 90 Elbow atalog Number Steel luminum in. mm in. mm in. mm 44-3RSL SIE 44-3RSL SIE RSL SIE 66-3RSL SIE RSL SIE 88-3RSL SIE ireway Tee Side opening hinge cover design for applications where a tee junction is necessary. ireway Tee atalog Number Steel luminum in. mm in. mm in. mm in. mm 44-3RST 44-3RST RST 66-3RST RST 88-3RST ireway ross Side opening cover design for applications where a cross junction is necessary. ireway ross atalog Number Steel luminum in. mm in. mm in. mm 44-3RSX 44-3RSX RSX 66-3RSX RSX 88-3RSX Line series electrical enclosures 23
18 able & ire Management able & ire Management Lay-In ireway Type 3R EnviroShield System Illustration Sheet and atalog Number ireway Reducer Screw opening cover design for applications where a change in wireway crosssection (height x width) is necessary. ireway Reducer atalog Number Steel luminum in. mm in. mm in. mm RSR RSR RSR RSR RSR RSR ireway Expansion Fitting Side opening hinge cover design for applications where expansion and contraction are a concern. raparound sleeve provides Type 3R rating and optional pad-locking tab. 8 (4).28 x 1.78 Slots ireway Expansion Fitting atalog Number Steel luminum in. mm in. mm 44-3RSXJ 44-3RSXJ RSXJ 66-3RSXJ RSXJ 88-3RSXJ Expansion Support Fitting esigned for applications where expansion and contraction are a concern. One expansion support is required at each support location. Slots allow single axis expansion and contraction movement. ia. (4).28 x 1.78 Slots 8 Expansion Support atalog Number Inside Steel luminum im. in. mm in. mm in. mm 44-3RSXS 44-3RSXS RSXS 66-3RSXS RSXS 88-3RSXS olt-on arrier For installations that require separated wiring compartments. n ideal solution for separating power from communication cables. * Not UL or S listed fitting ireway ireway Size atalog Number eight x epth Length eight Steel luminum x L in. mm in. mm in. mm 44-12K* 44-3RK* 4.00 x x K* 66-3RK* 6.00 x x K* 88-3RK* 8.00 x x L Line series electrical enclosures
19 able & ire Management Lay-In ireway Type 12 ata Sheet able & ire Management pplication ouses runs of control and power cable Protects against circulating dust, falling dirt and dripping noncorrosive liquids Standards UL 870 listed, unless noted S 22.2 No. 26 certified, unless noted onforms to NEM standard for Type 12 Finish ash and phosphate undercoat NSI 61 gray polyester powder finish ardware and latches are zinc plated ccessories Touch-up paint See ccessories section onstruction ireway body and cover are fabricated from (14) gauge steel Flanges are (10) gauge steel ll continuous welded seams are finished smooth External and internal edges are rounded to prevent injury or damage to cable overs are secured to the wireway and fitting body with heavy duty butt hinges and quick-release latches overs have a fixed, oil-resistant gasket n oil-resistant gasket is provided for installation between flanges ll covers and sealing plates can be hinged completely open or removed to allow for continuous lay-in cable feed ll straight sections and fittings are furnished with sealing plate kits (see pages 26-30) iscount Schedule: 2 Subclass: 90 -Line series electrical enclosures Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 25
20 able & ire Management able & ire Management Lay-In ireway Type 12 Illustration Sheet.765 (19) (86) Ø.281 (7) (4 PL) (64) (83) (90).765 (19) (124) Ø.281 (7) (4 PL) (102) (122) (52) 2.50 x (64) (79) (102) 4.00 x (102) (117) (143) (141).765 (19) (84).125 (3) (175).125 (3) Ø.281 (7) (7 PL) (153) (173) (192).765 (19) (110).125 (3) (225).125 (3) Ø.281 (7) (7 PL) (203) (224) 6.00 x (153) (168) (194) 8.00 x (204) (219) (245).765 (19) (327) (141) (84).125 (3).125 (3) Ø.281 (7) (8 PL) (105) (305) Flange etails x (321) (346) 26 -Line series electrical enclosures
21 able & ire Management Lay-In ireway Type 12 Illustration Sheet and atalog Number able & ire Management Length Straight Section includes (1) sealing plate kit atalog Size 22(*)-12L 2.5 x (*)-12L 4 x (*)-12L 6 x (*)-12L 8 x (*)-12L 12 x ctual Length For in. mm (*) Insert for length 04 = 4, 06 = 6, 12 = 12, 24 = 24, 36 = 36, 48 = 48, 60 = 60, 120 = (303) Transposition ireway Sections lockwise () includes (1) sealing plate kit ounterclockwise () includes (1) sealing plate kit atalog Size 22-12LTS(*) 2.5 x LTS(*) 4 x LTS(*) 6 x LTS(*) 8 x (*) Insert for lockwise Insert for ounterclockwise (303) 4.75 (121) (302) (305) Telescopic Fitting, Lay-In adjustable length from 1 to 7 includes hardware no cutting or welding required atalog Size 22-12LTF 2.5 x LTF 4 x LTF 6 x LTF 8 x LTF 12 x ut-off Fitting, Lay-In includes (1) sealing plate kit shorten body and cover to desired length and weld together, 9.50 minimum length atalog Size 22-12LF 2.5 x LF 4 x LF 6 x LF 8 x LF 12 x Line series electrical enclosures 27
22 able & ire Management able & ire Management Lay-In ireway Type 12 Illustration Sheet and atalog Number L 1 Nipple (LN1) includes hardware atalog Size 22-12LN(*) 2.5 x LN(*) 4 x LN(*) 6 x Nipple (LN2) 3 Nipple (LN3) includes hardware L 90 Elbow, Outside-Top Opening includes (2) sealing plate kits atalog Size in. mm in. mm 22-12LE9 2.5 x LE9 4 x LE9 6 x LE9 8 x LN(*) 8 x LN(*) 12 x (*) Insert 1 for 1 nipple (L=.938 ) Insert 2 for 2 nipple (L=1.938 ) Insert 3 for 3 nipple (L=2.938 ) 90 Elbow, Outside Opening includes (1) sealing plate kit 90 Elbow, Inside Opening includes (1) sealing plate kit atalog Size in. mm in. mm 22-12LE9 2.5 x LE9 4 x LE9 6 x LE9 8 x LE9 12 x atalog Size in. mm in. mm 22-12LE9 2.5 x LE9 4 x LE9 6 x LE9 8 x LE9 12 x Elbow, Top Opening includes (1) sealing plate kit atalog Size in. mm in. mm 22-12LE9 2.5 x LE9 4 x LE9 6 x LE9 8 x LE9 12 x Transposition Elbows lockwise () ounterclockwise () includes (1) sealing plate kit includes (1) sealing plate kit atalog Size in. mm in. mm 22-12LE9T(*) 2.5 x LE9T(*) 4 x LE9T(*) 6 x LE9T(*) 8 x (*) Insert for lockwise, Insert for ounterclockwise 28 -Line series electrical enclosures
23 able & ire Management Lay-In ireway Type 12 Illustration Sheet and atalog Number able & ire Management 45 Elbow, Top Opening includes (1) sealing plate kit atalog Size in. mm 22-12LE x LE45 4 x LE45 6 x LE45 8 x LE45 12 x Elbow, Inside Opening includes (1) sealing plate kit atalog Size in. mm 22-12LE x LE45 4 x LE45 6 x LE45 8 x LE45 12 x Elbow, Outside Opening includes (1) sealing plate kit atalog Size in. mm 22-12LE x LE45 4 x LE45 6 x LE45 8 x LE45 12 x Elbow, Top Opening includes (1) sealing plate kit atalog Size in. mm 22-12LE x LE15 4 x LE15 6 x LE15 8 x LE15 12 x L Tee, Top Opening includes (2) sealing plate kits atalog Size in. mm in. mm 22-12LT 2.5 x LT 4 x LT 6 x LT 8 x LT 12 x Tee, Outside Opening includes (2) sealing plate kits atalog Size L in. mm in. mm 22-12LT 2.5 x LT 4 x LT 6 x LT 8 x Line series electrical enclosures 29
24 able & ire Management able & ire Management Lay-In ireway Type 12 Illustration Sheet and atalog Number (305) (303) 6.00 (152) (305) (305) LS (303) dapters includes (2) sealing plate kits atalog Size ompetitor 22-12L 2.5 x offman 44-12L 4 x or 66-12L 6 x 6 iegmann L 8 x L 12 x LS 2.5 x LS 4 x LS 6 x 6 Square LS 8 x LS 12 x LM 2.5 x LM 4 x 4 ammond LM 6 x 6 Mfg LM 8 x LM 12 x Marks are the property of their respective owners. ross, Top Opening includes (3) sealing plate kits atalog Size in. mm in. mm 22-12L 2.5 x L 4 x L 6 x L 8 x L 12 x Reducer includes hardware atalog Size in. mm in. mm LR 4 x 4 to 2.5 x LR 6 x 6 to 4 x LR 8 x 8 to 6 x LR 12 x 6 to 4 x LR 12 x 6 to 6 x L (303) Lay-In to Feed Through dapter includes (1) sealing plate kit and (1) gasket kit atalog Size 44-12LF 4 x LF 6 x LF 8 x Junction ox includes (1) junction box sealing plate kit and (1) of the following removable panels: 22-12LJ = 108P 44-12LJ = 1210P 66-12LJ = 1412P 88-12LJ = 1614P atalog Size L in. mm in. mm 22-12LJ 2.5 x LJ 4 x LJ 6 x LJ 8 x Line series electrical enclosures
25 able & ire Management Lay-In ireway Type 12 Illustration Sheet and atalog Number Sealing Plate, Flat includes hardware atalog Size Number in. mm 22-12LSP 2.5 x LSP 4 x LSP 6 x LSP 8 x LSP 12 x (76).875 (22) (1524).875 (22) arrier, olt-on includes hardware atalog Size Number in. mm 22-12K 2.5 x K 4 x K 6 x K 8 x K 12 x able & ire Management ox onnector includes hardware atalog Size in. mm in. mm 22-12L 2.5 x L 4 x L 6 x L 8 x L 12 x losure Plate includes hardware atalog Size 1 2 in. mm 22-12LP 2.5 x LP 4 x LP 6 x LP 8 x LP 12 x (92) rop ireway angers includes wireway to bracket mounting hardware anchors not included atalog Size in. mm in. mm in. mm 22-12L 2.5 x L 4 x L 6 x L 8 x (57) racket atalog Size 1 2 in. mm 22-12L 2.5 x L 4 x L 6 x L 8 x Line series electrical enclosures 31
26 able & ire Management able & ire Management Feed-Through ireway Type 12 ata Sheet pplication ouses runs of control and power cable Protects against circulating dust, falling dirt and dripping noncorrosive liquids Standards UL 870 listed, unless noted S 22.2 No. 26 certified, unless noted onforms to NEM standard for Type 12 Finish ash and phosphate undercoat NSI 61 gray polyester powder finish ardware and latches are zinc plated ccessories Touch-up paint See ccessories section onstruction ireway body and cover are fabricated from (14) gauge steel Flanges are (10) gauge steel ll continuous welded seams are finished smooth External and internal edges are rounded to prevent injury or damage to cable overs are secured to the wireway body with heavy-duty hinges on one side and easy-to-operate screw clamps mounted to the opposite side ontinuous flanged ends assure rigid connections of wireway and fittings overs have a seamless poured in-place gasket n oil-resistant gasket is provided for installation between flanges iscount Schedule: 2 Subclass: 0 Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 32 -Line series electrical enclosures
27 able & ire Management Feed-Through ireway Type 12 Illustration Sheet and atalog Number 7.75 (197) 9.75 (248) able & ire Management 4.62 (117) 5.50 (140) 5.50 (140) L 3.31 (84) 3.31 (84) 7.75 (197) L 4.31 (109) 4.31 (109) 9.75 (248) 4.62 (117).12 (3) 3.31 (84) L 3.31 (84).12 (3).12 (3) 4.31 (109) L 4.31 (109).12 (3) 4.00 x x x 8.00 Flange etail outside flange gasket ireway Section lengths from (305 mm) to (3048 mm) inside flange (394) Length Straight Section includes (1) gasket kit atalog Size 44(*)-12F 4 x (*)-12F 6 x (*)-12F 8 x (*) Insert for length 12 = 12, 24 = 24, 36 = 36, 48 = 48, 60 = 60, 120 = 120. ctual Length For in. mm Telescopic Fitting adjustable lengths from 1.50 (38 mm) to (343 mm) no cutting or welding required atalog Size 44-12FTF * 4 x FTF * 6 x FTF * 8 x * Not UL or S Listed fitting. -Line series electrical enclosures 33
28 able & ire Management able & ire Management Feed-Through ireway Type 12 Illustration Sheet and atalog Number Flange (305) ut-off Fitting length up to (305 mm) shorten to desired length and weld on flange atalog Size * Nipple * lengths from 1.00 (25 mm) to 6.00 (152 mm) atalog Size 44-12FN(*) 4 x FN(*) 6 x FN(*) 8 x FF 4 x FF 6 x FF 8 x (*) Insert 1 for 1 nipple (L =.938 ) Insert 2 for 2 nipple (L = ) Insert 3 for 3 nipple (L = ) Insert 6 for 6 nipple (L = ) E E E losure Plate includes hardware ox onnector includes hardware Gasket atalog Size E 44-12FP 4 x FP 6 x FP 8 x atalog Size E 44-12F 4 x F 6 x F 8 x atalog Size E 44-12FGK 4 x FGK 6 x FGK 8 x enter Reducer includes hardware Edge atalog Number Size enter Edge in. mm in. mm FR FRE 6 to FR FRE 8 to (22) L (1518).87 (22) arrier, olt-on atalog Size eight Number in. mm 44-12K 4 x K 6 x K 8 x Line series electrical enclosures
29 able & ire Management Feed-Through ireway Type 12 Illustration Sheet and atalog Number rop E F G racket ireway angers includes wireway to bracket mounting hardware anchors not included atalog Number Size E F G rop racket in. mm in. mm in. mm in. mm in. mm x x x able & ire Management 3.50 to (89) (305) Flexible Fitting isolates wireway from shock or vibration and compensates for misalignment. 90 maximum angle. ypalon bellow with steel flanges. atalog Size Number in. mm 44-12FFF * 4 x FFF * 6 x FFF * 8 x * Not UL or S Listed fitting. 90 Elbow includes (1) gasket & hardware 45 Elbow includes (1) gasket & hardware atalog Size 44-12FE9 4 x FE9 6 x FE9 8 x atalog Size 44-12FE45 4 x FE45 6 x FE45 8 x L Tee includes (2) gaskets & hardware L L ross includes (3) gaskets & hardware atalog Size L in. mm 44-12FT 4 x FT 6 x FT 8 x atalog Size L in. mm 44-12F 4 x F 6 x F 8 x Notes: dimensions are from intersection of center lines. ll dimensions are to inside surfaces. llow.12 (3mm) for flange gasket when joining pieces. Flange holes are.28: dia. (7mm). Flange radii are.37 (9mm). imensions are in inches. Millimeters shown are for reference only. ata subject to change without notice. -Line series electrical enclosures 35
30 able & ire Management able & ire Management Feed-Through ireway Type 4X ata Sheet pplication ouses runs of control and power cables Intended for indoor or outdoor use where a corrosive environment exists Protects against corrosion, windblown dust and rain, splashing water and hose-directed water Standards UL 870 listed, unless noted S 22.2 No. 26 certified, unless noted onforms to NEM standard for Type 4X Finish Outer surface of wireway body and cover has a smooth brushed finish ireway body and cover is also available in Type 316 stainless steel upon special request ccessories ox connector losure plate arrier kit racket hanger rop hanger onstruction ireway body and cover are fabricated from (14) gauge Type 304 stainless steel Flanges are (10) gauge stainless steel ll continuous welded seams are finished smooth External and internal edges are rounded to prevent injury or damage to cable overs are secured to the wireway body with heavy-duty hinges on one side and easy-to-operate screw clamps mounted to the opposite side ontinuous flanged ends assure rigid connections of wireway and fittings over has a seamless poured in-place gasket n oil-resistant gasket is provided for installation between flanges iscount Schedule: 2 Subclass: Z70 Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 36 -Line series electrical enclosures
31 Feed-Through ireway Type 4X Illustration Sheet and atalog Number able & ire Management 7.75 (197) able & ire Management 4.62 (117) 5.50 (140) 5.50 (140) L 3.31 (84) 3.31 (84) 7.75 (197) 4.62 (117).12 (3) 3.31 (84) L 3.31 (84).12 (3) 4.00 x x 6.00 Flange etail outside flange Length Straight Section includes (1) gasket kit atalog Size 44(*)-4XSF 4 x (*)-4XSF 6 x (*) Insert for length 12 = 12, 24 = 24, 36 = 36, 48 = 48, 60 = 60, 120 = 120. ireway Section lengths from (305 mm) to (3048 mm) ctual Length For in. mm inside flange gasket (394) Telescopic Fitting adjustable lengths from 1.50 (38 mm) to (343 mm) no cutting or welding required atalog Size 44-4XSFTF * 4 x XSFTF * 6 x * Not UL or S Listed fitting. -Line series electrical enclosures 37
32 able & ire Management able & ire Management Feed-Through ireway Type 4X Illustration Sheet and atalog Number Flange (305) ut-off Fitting length up to (305 mm) shorten to desired length and weld on flange atalog Size 44-4XSFF 4 x XSFF 6 x * Nipple * lengths from 1.00 (25 mm) to 6.00 (152 mm) atalog Size 44-4XSFN(*) 4 x XSFN(*) 6 x (*) Insert 1 for 1 nipple (L =.938 ) Insert 2 for 2 nipple (L = ) Insert 3 for 3 nipple (L = ) Insert 6 for 6 nipple (L = ) E E E losure Plate includes hardware ox onnector includes hardware Gasket Kit atalog Size E 44-4XSFP 4 x XSFP 6 x atalog Size E 44-4XSF 4 x XSF 6 x atalog Size E 44-4XSFGK 4 x XSFGK 6 x enter Reducer includes hardware Edge atalog Number Size enter Edge in. mm in. mm XSFR XSFRE 6 to (22) L (1518).87 (22) arrier, olt-on atalog Size eight Number in. mm 44-12K 4 x K 6 x Line series electrical enclosures
33 able & ire Management Feed-Through ireway Type 4X Illustration Sheet and atalog Number rop E F G racket ireway angers includes wireway to bracket mounting hardware anchors not included atalog Number Size E F G rop racket in. mm in. mm in. mm in. mm in. mm 44-4XS 44-4XS 4 x XS 66-4XS 6 x able & ire Management 3.50 to (89) (305) Flexible Fitting isolates wireway from shock or vibration and compensates for misalignment. 90 maximum angle. ypalon bellow with steel flanges. atalog Size Number in. mm 44-4XSFFF * 4 x XSFFF * 6 x * Not UL or S Listed fitting. 90 Elbow includes (1) gasket & hardware 45 Elbow includes (1) gasket & hardware atalog Size 44-4XSFE9 4 x XSFE9 6 x atalog Size 44-4XSFE45 4 x XSFE45 6 x L Tee includes (2) gaskets & hardware L L ross includes (3) gaskets & hardware atalog Size L in. mm 44-4XSFT 4 x XSFT 6 x atalog Size L in. mm 44-4XSF 4 x XSF 6 x Notes: dimensions are from intersection of center lines. ll dimensions are to inside surfaces. llow.12 (3mm) for flange gasket when joining pieces. Flange holes are.28: dia. (7mm). Flange radii are.37 (9mm). imensions are in inches. Millimeters shown are for reference only. ata subject to change without notice. -Line series electrical enclosures 39
34 able & ire Management able & ire Management iring Troughs Type 1 Screw over ata Sheet pplication Used for indoor cable and wire junction, distribution, and termination applications where dirt, dust, oil, and water are not serious problems Standards UL 870 listed, Type 1 S 22.2 No. 26 certified, Type 1 onforms to NEM standard for Type 1 Finish Galvanized Steel onstruction overs and bodies are fabricated from code gauge galvanized steel (see table, page 41) odies have mounting holes on the back over is held secure to the body by plated screws Keyhole slots on the trough cover allow removal of cover without removing screws Shipped complete with permanently connected ends iscount Schedule: 2 Subclass: N1 ccessories See ccessories section Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 40 -Line series electrical enclosures
35 able & ire Management iring Troughs Type 1 Screw over Illustration Sheet and atalog Number atalog eight x epth x Length Number x x Gauge in. mm in. mm in. mm 4412 GTGV NK 4.00 x 4.00 x x 102 x GTGV NK 4.00 x 4.00 x x 102 x GTGV NK 4.00 x 4.00 x x 102 x GTGV NK 4.00 x 4.00 x x 102 x GTGV NK 4.00 x 4.00 x x 102 x GTGV NK 4.00 x 4.00 x x 102 x GTGV NK 6.00 x 6.00 x x 152 x GTGV NK 6.00 x 6.00 x x 152 x GTGV NK 6.00 x 6.00 x x 152 x GTGV NK 6.00 x 6.00 x x 152 x GTGV NK 6.00 x 6.00 x x 152 x GTGV NK 6.00 x 6.00 x x 152 x GTGV NK 8.00 x 8.00 x x 203 x GTGV NK 8.00 x 8.00 x x 203 x GTGV NK 8.00 x 8.00 x x 203 x GTGV NK 8.00 x 8.00 x x 203 x GTGV NK 8.00 x 8.00 x x 203 x GTGV NK x x x 254 x GTGV NK x x x 305 x GTGV NK x x x 305 x GTGV NK x x x 305 x able & ire Management (102) cover screw ireway Front mounting hole ireway Side -Line series electrical enclosures 41
36 able & ire Management able & ire Management iring Troughs Type 3R Screw over, Painted & Galvanized ata and Illustration Sheet Finish ash and phosphate undercoat or galvanized steel NSI 61 gray acrylic electrocoat finish ccessories Sealing devices Touch-up paint See ccessories section pplication ouses runs of control and power cable Used for cable and wire junction, distribution and termination Standards UL 870 listed, Type 3R S 22.2 No. 26 certified, Type 3R onforms to NEM standard for Type 3R onstruction ireway body and cover are fabricated from (16) gauge galvaneal steel for painted or galvanized steel ireway body has embossed mounting holes on the back ireway is available with or without knockouts on the bottom end only, (see drawing) over is held secure by sliding it under the top end flange and fastening it with plated screws on the bottom end flange Sealing screws and lances are located at each end of the wireway cover ireway exceeding 72 inches in length has two covers, a removable center channel and body supports iscount Schedule: 2 Subclass: M1 & Z (105) (57) sealing lance sealing screw ireway Front mounting hole 1.25 (32) J J J 1.56 (40) 3.00 (76) 3.00 (76) typ. spacing 3.00 (76) typ. spacing ireway ottom Knockout sizes: = 3 /4 or 1 /2 conduit J = 1 1 /4 or 1 conduit Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 42 -Line series electrical enclosures
37 able & ire Management iring Troughs Type 3R Screw over, Painted & Galvanized atalog Number ireway atalog Number ireway Size Painted Galvanized eight x epth x Length Knockout Quantity x x KO No KO KO No KO in. mm ottom 4412 GRT 4412 GRT NK GRTGV NK 4.00 x 4.00 x x 102 x GRT 4418 GRT NK x 4.00 x x 102 x GRT 4424 GRT NK GRTGV NK 4.00 x 4.00 x x 102 x GRT 4436 GRT NK GRTGV NK 4.00 x 4.00 x x 102 x GRT 4448 GRT NK GRTGV NK 4.00 x 4.00 x x 102 x GRT 4460 GRT NK GRTGV NK 4.00 x 4.00 x x 102 x GRT 4472 GRT NK GRTGV NK 4.00 x 4.00 x x 102 x GRT NK x 4.00 x x 102 x GRT NK GRTGV NK 4.00 x 4.00 x x 102 x GRT 6612 GRT NK GRTGV NK 6.00 x 6.00 x x 152 x GRT 6618 GRT NK GRTGV NK 6.00 x 6.00 x x 152 x GRT 6624 GRT NK GRTGV NK 6.00 x 6.00 x x 152 x GRT 6636 GRT NK GRTGV NK 6.00 x 6.00 x x 152 x GRT 6648 GRT NK GRTGV NK 6.00 x 6.00 x x 152 x GRT 6660 GRT NK GRTGV NK 6.00 x 6.00 x x 152 x GRT 6672 GRT NK GRTGV NK 6.00 x 6.00 x x 152 x GRT NK x 6.00 x x 152 x GRT NK GRTGV NK 6.00 x 6.00 x x 152 x GRT 8812 GRT NK GRTGV NK 8.00 x 8.00 x x 203 x GRT 8818 GRT NK x 8.00 x x 203 x GRT 8824 GRT NK GRTGV NK 8.00 x 8.00 x x 203 x GRT 8836 GRT NK GRTGV NK 8.00 x 8.00 x x 203 x GRT 8848 GRT NK GRTGV NK 8.00 x 8.00 x x 203 x GRT 8860 GRT NK GRTGV NK 8.00 x 8.00 x x 203 x GRT 8872 GRT NK GRTGV NK 8.00 x 8.00 x x 203 x GRT NK GRTGV NK 8.00 x 8.00 x x 203 x GRT NK GRTGV NK 8.00 x 8.00 x x 203 x GRT NK GRTGV NK x x x 254 x GRT NK GRTGV NK x x x 254 x GRT NK GRTGV NK x x x 254 x GRT NK GRTGV NK x x x 254 x GRT NK GRTGV NK x x x 254 x GRT NK GRTGV NK x x x 254 x GRT NK GRTGV NK x x x 254 x GRT NK GRTGV NK x x x 305 x GRT NK GRTGV NK x x x 305 x GRT NK GRTGV NK x x x 305 x GRT NK GRTGV NK x x x 305 x GRT NK GRTGV NK x x x 305 x GRT NK GRTGV NK x x x 305 x GRT NK GRTGV NK x x x 355 x GRT NK GRTGV NK x x x 355 x GRT NK GRTGV NK x x x 355 x GRT NK GRTGV NK x x x 355 x GRT NK GRTGV NK x x x 355 x able & ire Management -Line series electrical enclosures 43
38 able & ire Management able & ire Management iring Troughs Type 12 Lift-Off over ata Sheet pplication ouses runs of control and power cable Protects against circulating dust, falling dirt and dripping noncorrosive liquids Standards UL 870 listed S 22.2 No. 26 certified onforms to NEM standard for Type 12 Finish ash and phosphate undercoat NSI 61 gray polyester powder finish ardware and latches are zinc plated ccessories Touch-up paint See ccessories section onstruction ireway body and cover are fabricated from (14) gauge steel ll continuous welded seams are finished smooth over is secured to the wireway body with semi-hinges on one side and easy-to-operate screw clamps mounted to the opposite side Two chains hold cover to the body when screw clamps are released over has a seamless poured in-place gasket External mounting feet are provided for wall mounting iscount Schedule: 2 Subclass: 0 Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 44 -Line series electrical enclosures
39 able & ire Management iring Troughs Type 12 Lift-Off over Illustration Sheet and atalog Number 1.62 (41) 1.62 (41) clamp able & ire Management (28) L mounting feet (omit center foot where is less than 30) chain ireway Front (25) ireway Side Trough Trough Size idth x epth x Length x x atalog T 4.00 x 4.00 x x 102 x T 4.00 x 4.00 x x 102 x T 4.00 x 4.00 x x 102 x T 4.00 x 4.00 x x 102 x T 4.00 x 4.00 x x 102 x T 4.00 x 4.00 x x 102 x T 4.00 x 4.00 x x 102 x T 4.00 x 4.00 x x 102 x T 6.00 x 6.00 x x 152 x T 6.00 x 6.00 x x 152 x T 6.00 x 6.00 x x 152 x T 6.00 x 6.00 x x 152 x T 6.00 x 6.00 x x 152 x T 6.00 x 6.00 x x 152 x T 6.00 x 6.00 x x 152 x T 8.00 x 8.00 x x 203 x T 8.00 x 8.00 x x 203 x T 8.00 x 8.00 x x 203 x T 8.00 x 8.00 x x 203 x T 8.00 x 8.00 x x 203 x T 8.00 x 8.00 x x 203 x XX12-12T XX18-12T XX24-12T XX30-12T XX36-12T XX48-12T XX60-12T XX72-12T over lamp Layout -Line series electrical enclosures 45
40 able & ire Management able & ire Management iring Troughs Type 4X Lift-Off over ata Sheet pplication ouses runs of control and power cable Protects against corrosion, windblown dust and rain, splashing water and hose-directed water Standards UL 870 listed S 22.2 No. 26 certified onforms to NEM standard for Type 4X Finish Outer surface of wireway body and cover has a smooth brushed finish ccessories racket hanger rop hanger onstruction ireway body and cover are fabricated from (14) gauge Type 304 stainless steel ll continuous welded seams are finished smooth over is secured to the wireway body with semi-hinges on one side and easy-to-operate screw clamps mounted to the opposite side Two chains hold cover to the body when screw clamps are released over has a seamless poured in-place gasket External mounting feet are provided for wall mounting iscount Schedule: 2 Subclass: U10 Notes: e can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 46 -Line series electrical enclosures
41 able & ire Management iring Troughs Type 4X Lift-Off over Illustration Sheet and atalog Number Trough Trough Size idth x epth x Length x x atalog XST 4.00 x 4.00 x x 102 x XST 4.00 x 4.00 x x 102 x XST 4.00 x 4.00 x x 102 x XST 4.00 x 4.00 x x 102 x XST 4.00 x 4.00 x x 102 x XST 4.00 x 4.00 x x 102 x XST 4.00 x 4.00 x x 102 x XST 4.00 x 4.00 x x 102 x XST 6.00 x 6.00 x x 152 x XST 6.00 x 6.00 x x 152 x XST 6.00 x 6.00 x x 152 x XST 6.00 x 6.00 x x 152 x XST 6.00 x 6.00 x x 152 x XST 6.00 x 6.00 x x 152 x XST 6.00 x 6.00 x x 152 x able & ire Management 1.62 (41) 1.62 (41) clamp (28) L mounting feet (omit center foot where is less than 30) chain ireway Front (25) ireway Side XX12-12T XX18-12T XX24-12T XX30-12T XX36-12T XX48-12T XX60-12T XX72-12T over lamp Layout -Line series electrical enclosures 47
42 able & ire Management - Notes able & ire Management 48 -Line series electrical enclosures
Type 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
Series 1 Steel Cable Ladder
able Straight Sections See pages LDS-3 & LDS-4 Straight Section overs See page LDS-10 ccessories See pages LDS-5 - LDS-9 Fittings See pages LDS-11 - LDS-17 Fitting overs See page LDS-10 LDS-1 able Support
JIC CONTINUOUS HINGE BOXES
JIC CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing.
Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
Section H Index. www.hubbell-wiegmann.com Data Subject To Change Without Notice OPERATOR INTERFACE
Section H Index H1 W1 Series NEMA 12 onsoles...h2 W9 Series NEMA 12 onsoles...h4 W10 Series NEMA 12 onsoles...h6 W12 Series NEMA 12 onsoles...h8 W14 Series NEMA 12 onsoles...h10 W- Series NEMA 12 onsolets...h12
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Catalog Number. Type 1 Enclosure Flush Lock. New Flush lock
Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Type 1 Panel Enclosure Flush Lock Type 1 Enclosure Flush Lock T1EFL New Flush lock.886 dia. (22) Hole Pattern Detail Flush Locks are
multi-axis system ROBOTRAX cable 3D cable carrier system carrier
3D cable multi-ais 3D cable carrier system carrier system Key Features: Perfect for 3D multi-ais movement applications. Maintains a pre-determined minimum bend radius Open-style design allows for easy
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
Control Stations Made of Polyester Resin Series 8146
ontrol Stations Made of Polyester Resin www.stahl.de > s made of glass-fibre reinforced polyester resin > 8 basic enclosure sizes with various enclosure heights > an be combined to larger units > Equipped
SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB
SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB
www.hammondmfg.com General Accessories Hardware
Heavy Duty Door Clamping Junction Box Padlock Kit Quick Release Clamp Replacement hardware for use on all 1418 and 1447 Series enclosures. Formed heavy gauge stainless steel clamp with stainless steel
Cable Runways & Accessories
SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products
How To Fit A Steel Frame For A Steel Plate Uprights
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 01 33 02 34 03 35 04 36 05 37 06 38 07 39 08 40 09 41 10 42 11 43 12 13 14 15 16 17 18 19 20 21 22 23 24
CABINET OPTIONS AND DESIGNATORS
CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
Control and Distribution Boxes made of Stainless Steel Series 8150
www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with
TABLE OF CONTENTS. Section 1 Type 1 & 3R Enclosures pg. 2-19. Section 2 Type 4 & 12 Enclosures pg. 20-47
TLE OF CONTENTS Section 1 Type 1 & 3R pg. 2-19 Type 1 & 3R Section 2 Type 4 & 12 pg. 20-47 Section 3 Flange Mounted Disconnect pg. 48-89 Section 4 Type 4, 12 & 13 Oiltight pg. 90-111 Section 5 Pushbutton
Fittings, Tubing & Nipples
s, Tubing & Nipples P Series Pipe s s to 15,000 psi (1034 bar) Since 1945 Parker utoclave Engineers has designed and built premium quality valves, fittings and tubing. This commitment to engineering and
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
PROLINE Go l d Se r i e s. Desk Consoles and Accessories
Modular Enclosure Systems Application PROLINE Gold Series desk consoles are ergonomically designed for use in either a sitting or standing position. Single-access consoles have a front door and solid back.
LIQUIDTIGHT FITTINGS
ooper rouse-hinds LIQUITIGHT FITTINGS LiQuik Series no disassembly required! Liquidator Series Low Profile Series Zinc ie ast Series Non-Metallic Liquidtight Series LIQUITIGHT FITTINGS LiQuik Series Liquidator
A. Shop Drawing submittals shall include, but not be limited to, the following:
SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical
STB Series Enclosures
STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard
COMMERCIAL TYPE B GAS VENT MODEL E/V 10" 30"
OMMERIL TYPE GS VENT MODEL E/V 10" 30" www.eccomfg.com GS VENT 10" 30" EO INDEX DESRIPTION... 90 E/V PIPE ND FITTINGS 10" Model... 91 12" Model... 91 92 14" Model... 92 16" Model... 93 18" Model... 93
FiberGuide Fiber Management Systems. 4th Edition
FiberGuide Fiber Management Systems 4th Edition Table of Contents Introduction Introduction...1 A Variety of Solutions...2 Innovative Products...3 Features and Benefits... 4 Applications Combining System
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
Customized Server Cabinets
GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
SECTION 25110 TELECOMMUNICATION ROOMS
PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication
FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.
FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution
Undercarpet Cabling Products TE Connectivity Enterprise Networks Warranty Power Distribution Product Coverage* TE Connectivity warrants that all Undercarpet cabling system products within this catalog
Quick Connect Boxes Inside Gloveboxes
ULC Series Junction Boxes Quick Connect Boxes Inside Gloveboxes The ULC quick connect junction boxes are the essential elements to optimize the cabling inside gloveboxes. Large range Designed for nuclear
CT-02 CABLE TRAY SYSTEMS
CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry
RIGHT ANGLE CLINCH FASTENERS BULLETIN
BULLETIN R 215 R e v 515 PEM R NGLE fasteners provide strong right angle attachment points in sheet metal or PC boards. Types R and RS for metal are simply pressed into a rectangular mounting hole of the
TERMINATION ENCLOSURE OPTIONS
TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated
RAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame
Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22
SECTION 4: Cable Ladder Stainless Steel & Aluminium
SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE
CONCEALED BEARING HINGES StANLEy ARCHItECtuRAL HARDwARE STANLEY ARCHITECTURAL HARDWARE TABLE OF CONTENTS Page Table of contents...2 Company history...2 5 knuckle concealed bearing design...3 Full mortise
Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP
Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.
POWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
Duct Temperature Sensors
Duct s Model TE-701 / 702 RoHS More than 16 types of interchangeable NTC thermistors, precision platinum, nickel or balco RTDs are available for universal compatibility. Five installation options probe
Limit Switches/ Receptacle Assembly... For Nuclear Environments
180-302/402 Series Inside ontainment reas TM Limit Switches/ Receptacle ssembly... or Nuclear nvironments eatures: Qualified to I s 344-1975, 323-1974, and 382-1972. Manufactured to a quality assurance
Scepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
INSTLLTION INSTRUTIONS 24" (61.0 M) LTRI SINGL N OUL UILT-IN OVN Table of ontents UILT-IN OVN SFTY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements... 2 lectrical Requirements...
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
Installation Instructions READ BEFORE INSTALLING UNIT For SLO3 Air Conditoner (8,000~12,000 BTU)
RE EFORE INSTLLING UNIT For SLO3 ir onditoner (8,000~2,000 TU) INSTLLTION WRNINGS N UTION arefully read the installation manual before beginning. Follow each step as shown. Observe all local, state, and
FRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction
GEH6290 g Cable Operator Mechanisms for E150, SE150, SF250, and SG600 Spectra RMS Circuit Breakers Type SCH1/1X, SCH2/2X Flange-Mounted Handle Assemblies, Cable Series SC3L SC10L and Type SC0M1A, SCOM1EF,
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
ELECTRICAL CONNECTORS
ELECTRICAL CONNECTORS 07-09 00-09 04-09 99-09 116 ELECTRICAL CONNECTORS LIGHT POWER MODULES WORKS WITH STANDARD & LED BULBS! WORKS WITH STANDARD & LED BULBS! CALL US TODAY FOR YOUR MODULITE VEHICLE APPLICATION
DCF Optimized Rack System
Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that
Now Available in Black Zinc Nickel
847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
IMPORTANT SAFETY UPDATE
J. H. FLETCHER & CO. Box 2187 Huntington, WV 25722-2187 304/525-7811 FAX 304/525-4025 IMPORTANT SAFETY UPDATE INFORMATION BULLETIN NO. 87 TO: FROM: OWNERS OF ROOF DRILLS THAT ARE NOW USING THE DUST BAG
The Ornamental Aluminum Fence with No-Visible Fasteners
he Ornamental luminum Fence with No-Visible Fasteners FNC SOLUIONS IN ONMNL CHIN LINK WOOD PVC CCSS CONOL MPOY WWW.MCHNSMLS.COM 866-888-5611 VING SQU PMIUM Ornamental luminum Fence Systems Featuring the
CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions
Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE
Electrical Conduit & Fittings Catalog HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE Payment Terms: Payment terms are printed on every invoice. Invoices not paid in full by the net due
Unpacking, Installation, and Customization
Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
Rack installation instructions
Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:
Equipment. Metering. Metering Equipment 1. Contents
1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility CenterPoint Energy (Reliant & HL&P).............................
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-115C
Cable Tray Ladder, Trough, Channel, Under Floor, Shielded CH-11C Chalfant dvantages Why Chalfant? Chalfant knows its success over the past 7 years can be traced to providing more than just quality cable
Sarasota Splash Back Prep and Shine Paint Restorer Inside Front Cover
Caution: Read entire label before using product. Do-It-Yourself PAINT RESTORER KIT Kit Contains: 1-16 oz. Water-based, Biodegradeable Liquid Prep 1-16 oz. Aerosol Shine Spray 1 - Spray Nozzle 2 - Scrub
plenum slot diffusers
light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.
14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined
FAIRFIELD INDUSTRIES INC.
FAIRFIELD INDUSTRIES INC. v NEW PRICE SCHEDULE 4/1/201 SUPERSEDES 4/1/11 SPILL CONTAINMENT And STREET ACCESS MANHOLES for UNDERGROUND And ABOVEGROUND TANKS SPILL CONTAINMENT MANHOLES MONITOR WELL SERIES
DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending
Patent Pending DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications DuroSite Series LED High Bay Features & Benefits L70 rated for >100,000 hours @ 25 C ambient 5 year full performance
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
Aluminium Standard. Technical Data. Included in delivery
luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:
OGi Architectural Metal Solutions
SUNSHADE CATALOG 2009 A B O U T U S Corporate Headquarters - Operating in accordance with NAAMM standards, Ohio Gratings, Inc. began operations in Canton, Ohio in 1970 and expanded from 8,000 square feet
AIR CONDITIONING PRODUCTS COMPANY
Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter
VersaRack Installation Instructions. masterack. Tools Required:
masterack Versaack Installation Instructions ll of us at asterack wish to thank you for your purchase of the Versaack. We are proud of this product and hope that you fi nd it a functional as well as a
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications
Dialight Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Case Study: Rockline Case Study (Manufacturing)
