TABLE OF CONTENTS. Section 1 Type 1 & 3R Enclosures pg Section 2 Type 4 & 12 Enclosures pg
|
|
|
- Brittney Short
- 9 years ago
- Views:
Transcription
1 TLE OF CONTENTS Section 1 Type 1 & 3R pg Type 1 & 3R Section 2 Type 4 & 12 pg Section 3 Flange Mounted Disconnect pg Section 4 Type 4, 12 & 13 Oiltight pg Section 5 Pushbutton & Consolets pg Type 4 & 12 Flange-Mounted Disconnect Type 4,12 & 13 Oiltight Pushbutton & Consolets Section 6 Wireways & Trough Products pg Section 7 ccessories pg Wireways & Trough Products ccessories Index Locks & Latches Section 8 Locks & Latches pg Section 9 Index pg
2 Type 1 & 3R TYPE 1 SCREW COVER OXES ustin screw cover boxes are Underwriters Laboratories Listed for Junction and Pull box applications. ll screw cover boxes meet the general-purpose indoor requirements. Construction: Fabricated in accordance with UL specifications from code gauge steel. oxes are furnished with or without knockouts. If knockouts are requested, a combination of 1/2-3/4" and 3/4-1" standard conduit sizes are furnished. oxes under 48"x 36" have 5/16" mounted holes. oxes 48"x 36" and over have 7/16" mounted holes. Finish: ustin screw cover boxes are constructed standard in galvanized steel. n NSI 61 gray polyester powder coating over CRS is available on request. Options: Special knockouts or knockout arrangements. Special materials. Special finishes. Custom box size or construction. SEMS RE SPOT WELDED.31 DI. MTG. HOLE (4 PLCES) * *.500* C *THIS DIMENSION IS.750 WHEN "" ND "" RE 24 x 24 ND OVER **THIS DIMENSION IS WHEN "" ND "" RE 24 x 24 ND OVER INDUSTRY STNDRDS UL 50 Type 1 NEM Type 1 CUL Type 1
3 SCREW COVER OXES Type 1 & 3R Catalog undle undle Enclosure Knockout Knockout Catalog undle undle Enclosure Knockout Knockout Number Quantity Weight Size (xxc) Pattern Pattern Number Quantity Weight Size (xxc) Pattern () Pattern () Sides "" Sides "" Sides "" Sides "" -444S x4x S x36x6 N N -644S x4x S x48x6 N N -664S x6x4-864S x6x4-888S 1 7 8x8x8-1064S x6x S x10x8-1264S x6x4 C S x12x8 C C -884S x8x S x12x8 C C -1084S x8x S x12x8 D C -1284S x8x4 C S x12x8 D C S x10x S x15x8 C C S x10x4 C S x15x8 D C S x12x4 C C S x18x8 D D S x12x4 C C S x18x8 D D S x12x4 D C S x24x8 D D S x12x4 D C S x24x8 D D S x15x4 C C S x24x8 D D S x15x4 D C S x24x8 D D S x18x4 D D S x30x8 N N S x18x4 D D S x30x8 N N S x24x4 D D S x36x8 N N S x24x4 D D S x36x8 N N S x24x4 D D S x48x8 N N -666S x6x S x12x10 C C -866S x6x S x12x10 D C -1266S x6x6 C S x18x10 D D -886S x8x S x18x10 D D -1086S x8x S x24x10 D D -1286S x8x6 C S x24x10 D D S x10x S x30x10 N N S x10x6 C S x30x10 N N S x12x6 C C S x36x10 N N S x12x6 C C S x36x10 N N S x12x6 D C S x48x10 N N S X12X6 D C S X15X6 C C S x12x12 C C S X15X6 D C S x12x12 D C S x18x6 D D S x12x12 D C S x18x6 D D S x18x12 D D S x24x6 D D S x18x12 D D S x24x6 D D S x24x12 D D S x24x6 D D S x24x12 D D S x24x6 D D S x30x12 N N S x30x6 N N S x36x12 N N S x30x6 N N S x36x12 N N S x36x6 N N S x48x12 N N NOTE: Replace "S" Suffix with: SK: Screw Cover w/ko's SGK: Screw Cover Gray w/ko's SG: Screw Cover Gray POSSILE KNOCKOUT PTTERNS 1.63 "" KNOCKOUT PTTERN 1/2"-3/4" COMINTION "" KNOCKOUT PTTERN 1/2"-3/4" & 3/4"-1" COMINTION "C" KNOCKOUT PTTERN 1/2"-3/4" & 3/4"-1" COMINTION "D" KNOCKOUT PTTERN 1/2"-3/4" & 3/4"-1" COMINTION NOTE: REFER TO OX TLE FOR PPLICLE KNOCKOUT PTTERN
4 Type 1 & 3R TYPE 1 HINGED COVER OXES ustin hinge cover boxes are Underwriters Laboratories Listed for Cabinet and Cutout box applications. ll hinge cover boxes meet the general-purpose indoor requirements. Construction: Fabricated in accordance with UL specifications from code gauge steel. Hinge cover boxes with a maximum dimension of 18" are fabricated with formed hinges and a pull ring catch. oxes are furnished with or without knockouts. If knockouts are requested, a combination of 1/2"- 3/4" and 3/4" - 1" standard conduit sizes are furnished. ack of boxes have mounting holes. Finish: ustin hinge cover boxes are constructed standard in galvanized steel. n NSI 61 gray polyester powder coating is available on request. Options: Special knockouts or knockout arrangements. Special materials. Special finishes. Custom box size or construction. INDUSTRY STNDRDS UL 50 Type 1 NEM Type 1 CUL Type 1
5 HINGE COVER OXES Type 1 & 3R Catalog undle undle Enclosure KO Pattern KO Pattern Number Qty. Weight Size (xxc) "" Side "" Side -644HC x4x4-664HC x6x4-864HC x6x4-1064HC x6x4-1264HC x6x4 C -884HC x8x4-1084HC x8x4-1284HC x8x4 C HC x10x HC x10x4 C HC x12x4 C C HC x12x4 C C HC x12x4 D C HC X15X4 C C HC X15X4 D C HC x18x4 D D -666HC x6x6-866HC x6x6-886HC x8x6-1086HC x8x6-1286HC x8x6 C HC x10x HC x10x6 C HC x12x6 C C HC x12x6 C C HC x12x6 D C HC X15X6 C C HC X15X6 D C HC x18x6 D D NOTE: Replace "HC" Suffix with: HCK: Hinge Cover w/ko's HCGK: Hinge Cover Gray w/ko's HCG: Hinge Cover Gray "" KNOCKOUT PTTERN 1/2"-3/4" COMINTION "C" KNOCKOUT PTTERN 1/2"-3/4" & 3/4"-1" COMINTION POSSILE KNOCKOUT PTTERNS "" KNOCKOUT PTTERN 1/2"-3/4" & 3/4"-1" COMINTION "D" KNOCKOUT PTTERN 1/2"-3/4" & 3/4"-1" COMIN NOTE: REFER TO OX TLE FOR PPLICLE KNOCKOUT PTTERN 5
6 Type 1 & 3R TYPE 3, 12 SCREW COVER GSKETED OXES ustin gasketed screw cover boxes are Underwriters Laboratories Listed for Wiring, Pull, Terminal, and Junction box application. They provide a degree of protection against rain, sleet, dust, dirt, external ice formation, and noncorrosive liquids. Construction: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. No mounting holes or mounting feet. Finish: ustin gasketed screw cover boxes are constructed standard in galvanized steel. n NSI 61 gray polyester powder coating over phosphatized surfaces is available on request. Options: Special materials. Special finishes. Custom box size or construction. SEMS RE WELDED SOLID ND GROUND SMOOTH.50* GSKET "MX. 6" MX C * THIS DIMENSION IS.750 WHEN "" ND "" RE OVER 18" INDUSTRY STNDRDS UL 50 Types 3 & 12 NEM Types 3 & 12 (except for mounting provisions) CUL Types 3 & 0
7 SCREW COVER GSKETED OXES Type 1 & 3R Catalog Enclosure Weight Catalog Enclosure Weight Number Size (xxc) Number Size (xxc) -444GS 4x4x GS 8x8x GS 6x6x GS 12x12x GS 8x6x GS 18x18x GS 8x8x GS 24x24x GS 10x8x GS 30x24x GS 10x10x GS 36x24x GS 12x10x GS 30x30x GS 12x12x GS 36x30x GS 18x18x GS 6x6x GS 24x24x GS 12x6x GS 30x24x GS 8x8x GS 36x24x GS 10x10x GS 30x30x GS 12x12x GS 36x30x GS 15x12x GS 15x15x GS 18x18x GS 18x18x GS 24x24x GS 24x18x GS 30x30x GS 24x24x GS 36x36x NOTE: Replace "GS" Suffix with: GSG: Gasket Screw Cover ox Gray 7
8 Type 1 & 3R TYPE 3R RINPROOF OXES ustin rainproof boxes are Underwriters Laboratories Listed for Wiring or Junction box applications. ll rainproof boxes are designed for outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. Construction: Fabricated in accordance with UL specifications from code gauge steel. Dripshield along top of box. Slip-on seamless cover attached by screws at bottom edge. Embossed mounting holes on back of enclosure. Finish: ustin rainproof boxes are constructed standard in galvanized steel. n NSI 61 gray polyester powder coating over phosphatized surfaces is provided on request. Options: Special knockouts or knockout arrangements in bottom only. Special materials. Special finishes. Custom box size or construction DI. MTG. HOLE (4 PLCES) C INDUSTRY STNDRDS UL 50 Type 3R NEM Type 3R CUL Type 3R
9 RINPROOF OXES Type 1 & 3R Catalog undle undle Enclosure Catalog undle undle Enclosure Number Quantity Weight Size (xxc) Number Quantity Weight Size (xxc) -664R x6x R x12x6-864R x6x R x12x6-884R x8x R x15x6-1084R x8x R x18x R x10x R x24x6-1284R x8x R x12x R x15x R x18x8-666R x6x R x18x8-886R x8x R x24x R x10x R x12x R x24x10 NOTE: Replace "R" Suffix with: RG: Rainproof Gray 9
10 Type 1 & 3R TYPE 1 SMLL NEM 1 O.E.M. CINET ustin Small O.E.M. enclosures are Underwriters Laboratories Listed and designed for use as control and instrument enclosures which do not require an oil-tight or dust-tight rating. Construction: Fabricated in accordance with UL specifications from code gauge steel. Continuous hinge. Finish: ustin Small O.E.M. enclosures are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white. Flush latch; -14. Stand-offs provided for mounting optional panel. Options: Special materials. Special finishes. Custom box size or construction. CONTINUOUS HINGE -14 (QURTER-TURN LTCH).31 DI. MTG. HOLE (4 PLCES) PNEL (Optional) C #10-32x.50 PRESS IN STND-OFF FOR OPTIONL PNEL INDUSTRY STNDRDS UL 50 Type 1 NEM Type 1 CUL Type 1
11 SMLL NEM 1 O.E.M. CINET Type 1 & 3R Catalog Enclosure Weight Panel Number Size (xxc) Catalog -664SM 6x6x4 4-66NP -864SM 8x6x4 4-86NP -884SM 8x8x4 6-88NP -1084SM 10x8x NP SM 10x10x NP SM 12x10x NP SM 12x12x NP SM 14x12x NP -866SM 8x6x6 5-86NP -886SM 8x8x6 6-88NP -1086SM 10x8x NP SM 10x10x NP SM 12x10x NP SM 12x12x NP SM 14x12x NP SM 12x12x NP SM 14x12x NP 11
12 Type 1 & 3R TYPE 1 LRGE NEM 1 O.E.M. CINET ustin Large O.E.M. enclosures are Underwriters Laboratories Listed and designed for housing electrical and electronic controls. Construction: -16 LTCH Fabricated in accordance with UL specifications from code gauge steel. Removable mounting panel. Continuous hinge. have an -16 flush latch except as noted. Finish: ustin Large O.E.M. enclosures are provided standard with an NSI 61 gray polyester powder coating. Panels are painted white OMIT CENTER STUDS IF "" IS LESS THN 31" Options: Special materials. Special finishes. FRONT VIEW w/door & HINGE REMOVED Custom box size or construction. C 1.00 INDUSTRY STNDRDS UL 50 Type 1 NEM Type 1 CUL Type 1
13 LRGE O.E.M. CINET ENCLOSURES WITH PNELS Type 1 & 3R Catalog Enclosure Weight Number Size (xxc) LM 16x12x6 5/ LM 16x16x6 5/ LM 20x16x6 5/ LM 24x16x6 5/ LM 20x20x6 5/ LM 24x20x6 5/ LM 24x24x6 5/ LM 30x24x6 5/ LM 36x24x6 5/ LM* 36x30x6 5/ LM 16x12x8 5/ LM 20x16x8 5/ LM 20x20x8 5/ LM 24x20x8 5/ LM 24x24x8 5/ LM 30x24x8 5/ LM 36x24x8 5/ LM* 36x30x8 5/ LM 24x20x10 5/ LM 30x24x10 5/ LM* 36x30x10 5/ LM 24x24x12 5/ LM* 36x30x12 5/8 123 *NOTE: If "" and "" are 36 x 30, an -10 tee handle is standard 13
14 Type 1 & 3R TYPE 1 TELEPHONE CINETS ustin Telephone Cabinets are Underwriters Laboratories Listed and are designed for use in telephone, panel junction, or cutout cabinet applications. They provide a degree of protection against limited amounts of dirt. -16 LTCH Construction: Fabricated in accordance with UL specifications from code gauge steel. Removable trim. Cabinets 36" and under have an -16 flush locking latch. Cabinets 37" and over have an -6 three point latch handle with roller arms. Finish: ustin Telephone Cabinets are furnished standard with an NSI 61 gray polyester powder coating. ox is furnished in galvanized steel. Options: Special finishes. Surface or flush covers. Continuous hinge. Optional ackboard studs for mounting optional ackboard. Custom box size or construction. TYPE D+.75 D -6 HNDLE -7 w/lock (Optional) C C WOOD CKORD (Optional) FLUSH MOUNT WOOD CKORD (Optional) SURFCE MOUNT TYPE TELEPHONE CINET IS VILLE w/doule DOORS ND LEVER HNDLE TYPE INDUSTRY STNDRDS UL 50 Type 1 NEM Type 1 CUL Type 1
15 TELEPHONE CINETS ND PLYWOOD CKORDS Type 1 & 3R Catalog Type Enclosure "D" Weight ackboard Panel Catalog Type Enclosure "D" Weight ackboard Panel Number Size (xxc) Catalog Weight Number Size (xxc) Catalog Weight Number Number -884T 8x8x4 1 1/16" 7 N N T 16x12x6 1 1/16" T T 10x10x4 1 1/16" T T 18x12x6 1 1/16" T T 12x12x4 1 1/16" T T 24x12x6 1 1/16" T T 16x12x4 1 1/16" T T 18x18x6 2 1/4" T T 18x12x4 1 1/16" T T 24x18x6 2 1/4" T T 24x12x4 1 1/16" T T 30x18x6 2 1/4" T T 18x18x4 2 1/4" T T 24x24x6 2 1/4" T T 24x18x4 2 1/4" T T 30x24x6 2 1/4" T T 30x18x4 2 1/4" T T 36x24x6 2 1/4" T T 24x24x4 2 1/4" T T 30x30x6 2 1/4" T T 30x24x4 2 1/4" T T 36x30x6 2 1/4" T T 36x24x4 2 1/4" T T 48x30x6 3 1/4" T T 30x30x4 2 1/4" T T 48x36x6 3 1/4" T T 36x30x4 2 1/4" T T 48x30x4 3 1/4" T 8 15
16 Type 1 & 3R NEM TYPE 3R SMLL WETHERPROOF CINETS ustin small hinge cover NEM 3R cabinets are Underwriters Laboratories Listed and designed for outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. Construction: Finish: Options: Fabricated in accordance with UL specifications from code gauge steel. Galvanized continuous hinge with stainless steel hinge pin. Draw pull catch; -1. Seamless dripshield. External mounting feet. Stand-offs provided for mounting optional panel. ustin small hinge cover NEM 3R cabinets are constructed standard in galvanized steel with an NSI 61 gray polyester powder coating. Optional panels are painted white. Special knockouts or knockout arrangements in bottom only. Special materials. Special finishes. Custom box size or construction PNEL OPTIONL DOOR HINGE SIDE C PDLOCKLE DRW PULL LTCH INDUSTRY STNDRDS UL 50 Type 3R NEM Type 3R CUL Type 3R
17 NEM TYPE 3R SMLL WETHERPROOF CINETS Type 1 & 3R Catalog Enclosure Weight Panel Catalog Panel Number Size (xxc) Number Weight -664WS 6x6x4 5-66NP WS 8x6x4 6-86NP 1-886WS 8x8x6 8-88NP WS 10x8x NP WS 10x10x NP WS 12x10x NP WS 12x12x NP WS 14x12x NP 3 17
18 NEM TYPE 3R LRGE WETHERPROOF CINETS Type 1 & 3R Catalog Enclosure Weight Panel Catalog Panel Catalog Enclosure Weight Panel Catalog Panel Number Size (xxc) Number Weight Number Size (xxc) Number Weight WL 16x12x TP WL 24x24x TP WL 16x16x TP WL 36x24x TP WL 20x16x TP WL 36x36x TP WL 24x18x TP WL 48x48x TP WL 24x24x TP WL 36x36x TP WL 30x30x TP WL 36x24x TP WL 20x20x TP WL 36x30x TP WL 24x20x TP WL 36x36x TP WL 24x24x TP WL 42x30x TP WL 30x24x TP WL 42x36x TP WL 36x24x TP WL 48x36x TP WL 36x30x TP WL 48x48x TP WL 36x36x TP WL 60x36x TP 61 19
19 NEM TYPE 3R LRGE WETHERPROOF CINETS Type 1 & 3R Catalog Enclosure Weight Panel Catalog Panel Catalog Enclosure Weight Panel Catalog Panel Number Size (xxc) Number Weight Number Size (xxc) Number Weight WL 16x12x TP WL 24x24x TP WL 16x16x TP WL 36x24x TP WL 20x16x TP WL 36x36x TP WL 24x18x TP WL 48x48x TP WL 24x24x TP WL 36x36x TP WL 30x30x TP WL 36x24x TP WL 20x20x TP WL 36x30x TP WL 24x20x TP WL 36x36x TP WL 24x24x TP WL 42x30x TP WL 30x24x TP WL 42x36x TP WL 36x24x TP WL 48x36x TP WL 36x30x TP WL 48x48x TP WL 36x36x TP WL 60x36x TP 61 19
20 NEM 4, 12 STYLE-LINE ENCLOSURES Type 4 & 12 ustin Style-Line enclosures are Underwriters Laboratories Listed and are designed to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. Construction: X SECTION X-X X 3/8"-16 COLLR STUD (4 PLCES) NEOPRENE GSKET (3/16 x 3/4) DOOR OPENED 180 1/4 TURN N-4 LTCH w/recessed SLOT GROUND STUD (10-32 PEM STUD) FRONT VIEW M6x10 HEX HD SCREW ZINC PLTED PNEL (Optional) C.437 DI. TYP. MTG. HOLE REMOVLE PIN 180 HINGE GROUND STUD (10-32 PEM STUD) Fabricated in accordance with UL specifications from UL approved gauge steel. Continuously welded seams ground smooth. Standard collar studs for mounting optional panel. Mounting holes in back of enclosure for direct mounting or for optional external mounting feet. Enclosure opening has a rolled lip to exclude liquids and contaminants. Doors can be easily removed by pulling captive hinge pins. Neoprene gasket attached to door with oil resistant adhesive. Grounding stud in body. Door stiffener and/or body stiffener required for larger sizes. Quarter turn latches for enclosures up through 36". Three-point latch on enclosures over 36"..25 DI. HINGE MTG. HOLE (2 PLCES) PNEL FRONT VIEW w/door REMOVED INDUSTRY STNDRDS UL 50 Types 4 & 12 UL 508 Types 4 & 12 CUL Types 4 & 12 NEM Types 4 & 12
21 NEM 4, NEM 12 STYLE-LINE ENCLOSURES Finish: ustin Style-Line enclosures are provided standard with an NSI 61 gray polyester powder coating inside and out. Stainless steel Style-Line enclosures are provided standard in Type 304 stainless steel. Optional panels are painted white. Type 4 & 12 Options: Special finishes. Handles or inserts 21
22 NEM 4, 12 STYLE-LINE ENCLOSURES Type 4 & 12 REMOVLE PIN 180 HINGE DOOR STIFFENER MOUNTED HORIZONTL (INSIDE DOOR) 3 POINT LTCH N-4 w/pdlocking SLOT X X GROUND STUD (10-32 PEM STUD INSIDE DOOR) PNEL (Optional) GROUND STUD (10-32 PEM STUD INSIDE ENCLOSURE) FRONT VIEW C.437 DI. TYP. MTG. HOLE LEFT SIDE VIEW 3/8"-16 COLLR STUD (8 PLCES) PNEL (Optional) ODY STIFFENER MOUNTED HORIZONTL (INSIDE ENCLOSURE).25 DI. HINGE MTG HOLE 60 NEOPRENE GSKET (3/16 x 3/4) DOOR OPENED M6x10 HEX HD SCREW ZINC PLTED FRONT VIEW w/door REMOVED SECTION X-X INDUSTRY STNDRDS UL 50 Types 4 & 12 UL 508 Types 4 & 12 CUL Types 4 & 12 NEM Types 4 & 12
23 NEM 4, NEM 12 STYLE-LINE ENCLOSURES Type 4 & 12 Catalog Number Catalog Number Enclosure Weight Panel Catalog Door ody Hinge Latch Stainless Steel Size (xxc) Number Stiffener Stiffener Qty. Qty SL SLX 12x12x TP SL SLX 16x12x TP SL SLX 16x16x TP SL SLX 20x16x TP SL SLX 20x20x TP SL SLX 16x20x TP SL SLX 20x16x TP SL SLX 20x20x TP SL SLX 20x24x TP SL SLX 24x16x TP SL SLX 24x20x TP SL SLX 24x24x TP SL SLX 24x30x TP SL SLX 30x20x TP SL SLX 30x24x TP SL SLX 30x30x TP SL SLX 36x24x TP SL SLX 36x30x TP SL SLX 20x20x TP SL SLX 24x24x TP SL SLX 30x24x TP SL SLX 36x30x TP SL SLX 36x36x TP SL SLX 40x24x TP pt SL SLX 42x36x TP pt SL SLX 48x24x TP pt SL SLX 48x36x TP pt SL SLX 60x24x TP pt SL SLX 60x36x TP pt SL SLX 24x24x TP SL SLX 36x30x TP SL SLX 48x36x TP pt. 23
24 NEM 4 SINGLE DOOR ENCLOSURES Type 4 & 12 ustin NEM 4 single door enclosures are Underwriters Laboratories Listed and are designed for use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Fabricated in accordance with UL specifications from code gauge steel. ll seams continuously welded and ground smooth. Rolled lip around three sides of door and all sides of door opening for watertight seal. Door removed by pulling stainless steel continuous hinge pin. Neoprene gasket attached to door with oil resistant adhesive. Clamps on three sides of door for watertight seal. Stainless steel external hardware..63 Y * THIS DIMENSION IS 1.50" WHEN "" IS LESS THN 16.00" 3.00* 3.00* Y 1.06 C X Hasp and staple provided for padlocking. External mounting feet. Standard plastic self-adhesive print pocket. PDDLOCK TYPE HSP Standard collar studs for mounting optional panel. Finish:.63 MXIMUM CLMP SPCING IS 15.00" 4.00 OR (TYP) 6.00 DEPENDING ON ENCLOSURE SIZE X ustin NEM 4 single door enclosures are provided standard with an NSI 61 gray polyester powder coating inside and out. Optional panels are painted white..43 DI. Options: PNEL (Optional) OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" CONTINUOUS HINGE GSKET Special materials. Special finishes. OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" /8-16 COLLR STUD 1.00 SECTION Y-Y Custom box size or construction. SECTION X-X INDUSTRY STNDRDS UL 50 Types 4 & 12 UL 508 Types 4 & 12 NEM Types 4 & 12 CUL Types 4 & 12
25 NEM 4 SINGLE DOOR ENCLOSURES Catalog Enclosure Weight Panel Catalog Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number Number Size (xxc) Number NF 16x12x TP NF 30x30x TP NF 16x16x TP NF 36x24x TP NF 20x16x TP NF 36x30x TP NF 16x20x TP NF 42x30x TP NF 20x20x TP NF 42x36x TP NF 24x12x TP NF 48x36x TP NF 24x16x TP NF 60x36x TP NF 24x20x TP NF 24x24x TP NF 30x20x TP NF 20x16x TP NF 30x24x TP NF 24x20x TP NF 36x24x TP NF 30x24x TP NF 36x30x TP NF 16x12x TP NF 48x30x TP NF 20x16x TP NF 48x36x TP NF 20x20x TP NF 60x36x TP NF 24x20x TP NF 24x24x TP NF 30x24x TP NF 30x20x TP NF 36x30x TP NF 30x24x TP NF 48x36x TP Type 4 & 12 25
26 NEM 4 DOULE DOOR ENCLOSURES Type 4 & 12 ustin NEM 4 double door enclosures are Underwriters Laboratories Listed and designed for use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Fabricated in accordance with UL specifications from code gauge steel. Rolled lip around three sides of door and along top of enclosure for watertight seal. ll seams continuously welded and ground smooth. Removable centerpost with gasket. Neoprene gasket attached to doors with oil resistant adhesive. Clamps on three sides of door for watertight seal. Stainless steel external hardware. Finish: Hasp and staple provided for padlocking. Standard plastic self-adhesive print pocket. 12" floor stands welded on. Heavy duty lifting eyes. Standard collar studs for mounting optional panel. LIFTING EYE 1.25" C T ustin NEM 4 double door enclosures are provided standard with an NSI 61 gray polyester powder coating inside and out. Optional panels are painted white. Options: HSP FOR PDLOCK Special materials. Special finishes. Custom box size or construction. 15"MX S S REMOVLE CENTERPOST T - 4" CONTINUOUS HINGE GSKET PNEL (Optional) /8-16 COLLR STUD " 1.00 SECTION S-S SECTION T-T INDUSTRY STNDRDS UL 50 Types 4 & 12 UL 508 Types 4 & 12 NEM Types 4 & 12 CUL Types 4 & 12
27 NEM 4 DOULE DOOR ENCLOSURES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number Type 4 & NFD 62x48x DP NFD 62x60x DP NFD 74x60x DP NFD 74x72x DP 27
28 NEM 4X STINLESS STEEL ENCLOSURES Type 4 & 12 ustin NEM 4X stainless steel single door enclosures are Underwriters Laboratories Listed and are designed for use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Fabricated in accordance with UL specifications from 14 or 12 gauge Type 304 stainless steel standard, Type 316 stainless steel optional. ll seams continuously welded and ground smooth. Rolled lip around three sides of door and all sides of door opening for watertight seal. Neoprene gasket attached to door with oil resistant adhesive. Clamps on three sides of door for watertight seal. Stainless steel external hardware. Hasp and staple provided for padlocking. External mounting feet. Standard plastic self-adhesive print pocket..63 * THIS DIMENSION IS 1.50" WHEN "" IS LESS THN 16.00" 3.00* 3.00* 1.06 C X Standard collar studs for mounting optional panel. Y Y Finish: PDDLOCK TYPE HSP ustin NEM 4X stainless steel single door enclosures are provided standard in type 304 polished stainless steel. Optional panels are painted white, stainless steel panels are unpainted OR (TYP) MXIMUM CLMP SPCING IS 15.00" DEPENDING ON ENCLOSURE SIZE X Options: Custom box size or construction..43 DI. Type 316 stainless steel. PNEL (Optional) OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" CONTINUOUS HINGE GSKET /8-16 COLLR STUD OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" SECTION Y-Y SECTION X-X INDUSTRY STNDRDS UL 50 Types 4X, 4 & 12 UL 508 Types 4X, 4 & 12 NEM Types 4X, 4 & 12 CUL Types 4X, 4 & 12
29 STINLESS STEEL NEM 4X ENCLOSURES Type 4 & 12 Catalog Enclosure Enclosure Panel Catalog Panel Catalog Enclosure Enclosure Panel Catalog Panel Number Size (xxc) Weight Number Weight Number Size (xxc) Weight Number Weight NFX 16x12x TP NFX 48x36x TP NFX 16x16x TP NFX 20x16x TP NFX 20x16x TP NFX 20x20x TP NFX 24x20x TP NFX 24x24x TP NFX 36x24x TP NFX 36x30x TP NFX 24x24x TP NFX 42x30x TP NFX 24x30x TP NFX 30x20x TP NFX 24x24x TP NFX 30x24x TP NFX 30x24x TP NFX 36x24x TP NFX 36x30x TP NFX 36x30x TP NFX 48x36x TP NFX 42x36x TP NFX 60x36x TP 61 *Optional stainless steel panels are available 29
30 NEM 4X LUMINUM ENCLOSURES Type 4 & 12 ustin NEM 4X aluminum enclosures are Underwriters Laboratories Listed and are designed for use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Fabricated in accordance with UL specifications form Type 5052-H32 aluminum. ll seams continuously welded and ground smooth. Rolled lip around three sides of door and all sides of door opening for watertight seal. Neoprene gasket attached to door with oil resistant adhesive. Clamps on three sides of door for watertight seal. luminum continuous hinge. Stainless steel external hardware. Hasp and staple provided for padlocking. External mounting feet Standard plastic selfadhesive print pocket. Standard collar studs for mounting optional panel. * THIS DIMENSION IS 1.50" WHEN "" IS LESS THN 16.00" Finish:.63 Y 3.00* 3.00* Y 1.06 PDDLOCK TYPE HSP C X ustin NEM 4X aluminum enclosures are provided standard in Type 5052-H32 aluminum. Optional panels are painted white. luminum panels are unpainted..63 MXIMUM CLMP SPCING IS 15.00" 4.00 OR 6.00 (TYP) DEPENDING ON ENCLOSURE SIZE X Options: Custom box size or construction. Custom box size or construction..43 DI. PNEL (Optional) OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" CONTINUOUS HINGE GSKET /8-16 COLLR STUD OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" SECTION Y-Y SECTION X-X INDUSTRY STNDRDS UL 50 Types 4X, 4 & 12 UL 508 Types 4X, 4 & 12 NEM Types 4X, 4 & 12 CUL Types 4X, 4 & 12
31 LUMINUM NEM 4X ENCLOSURES Catalog Enclosure Weight Steel Panel Number Size (xxc) Catalog Number NF 16x12x TP NF 20x16x TP NF 20x20x TP NF 24x20x TP Type 4 & NF 24x24x TP NF 30x24x TP NF 36x24x TP NF 36x30x TP NF 48x36x TP NF 20x16x TP NF 24x20x TP NF 30x24x TP NF 36x30x TP NF 60x36x TP *Optional aluminum panels are available 31
32 NEM 12 SINGLE DOOR ENCLOSURES Type 4 & DI. PNEL (Optional) OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" SECTION X-X * THIS DIMENSION IS 1.50" WHEN "" IS LESS THN 16.00" * 3.00* 1.06 C X Y Y PDLOCK TYPE HSP DDITIONL CLMP USED IN CENTER WHEN "" EXCEEDS 47" ND HSP MOVED UP (TYP).63 X CONTINUOUS HINGE GSKET /8-16 COLLR STUD 1.00 SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 UL 508 Type 12 NEM Type 12 CUL Type 12
33 NEM 12 SINGLE DOOR ENCLOSURES ustin NEM 12 single door enclosures are Underwriters Laboratories Listed and are designed for indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Type 4 & 12 Construction: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Door removed by pulling continuous hinge pin. Neoprene gasket attached to door with oil resistant adhesive. Hasp and staple provided for padlocking. External feet for mounting enclosure. Finish: ustin Type 12 Single door enclosures are provided standard with an NSI 61 gray polyester powder coating inside and out. Optional panels are finished white. Options: Special materials. Special finishes. Custom box size or construction. Custom box size or construction. Standard plastic self-adhesive print pocket. Standard collar studs for mounting optional panel. 33
34 NEM 12 SINGLE DOOR ENCLOSURES Type 4 & 12 * THIS DIMENSION IS 1.50" WHEN "" IS LESS THN 16.00" * 3.00* 1.06 C X.43 DI. Y Y PNEL (Optional) PDLOCK TYPE HSP OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" (TYP).63 X SECTION X-X CONTINUOUS HINGE GSKET /8-16 COLLR STUD 1.00 SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 UL 508 Type 12 NEM Type 12 CUL Type 12
35 NEM 12 SINGLE DOOR ENCLOSURES Catalog Enclosure Enclosure Panel Catalog Panel Catalog Enclosure Enclosure Panel Catalog Panel Number Size (xxc) Weight Number Weight Number Size (xxc) Weight Number Weight Type 4 & N 12x24x TP N 20x20x TP N 16x12x TP N 24x12x TP N 16x16x TP N 24x20x TP N 20x12x TP N 24x24x TP N 20x16x TP N 30x20x TP N 16x20x TP N 30x24x TP N 20x20x TP N 36x24x TP N 24x12x TP N 36x30x TP N 24x16x TP N 42x30x TP N 20x24x TP N 42x36x TP N 24x20x TP N 48x30x TP N 24x24x TP N 48x36x TP N 30x16x TP N 60x36x TP N 30x20x TP N 30x24x TP N 20x16x TP N 36x24x TP N 24x20x TP N 36x30x TP N 24x24x TP N 30x24x TP N 16x12x TP N 30x30x TP N 16x16x TP N 36x24x TP N 20x12x TP N 36x30x TP N 20x16x TP N 36x36x TP N 16x20x TP N 42x30x TP N 20x20x TP N 42x36x TP N 24x12x TP N 48x36x TP N 12x24x TP N 60x36x TP N 24x16x TP N 72x30x TP N 24x20x TP N 20x24x TP N 24x24x TP N 24x20x TP N 30x20x TP N 24x24x TP N 30x24x TP N 30x24x TP N 24x30x TP N 36x30x TP N 30x30x TP N 42x36x TP N 36x24x TP N 48x36x TP N 36x30x TP N 60x36x TP N 30x36x TP N 72x30x TP N 36x36x TP N 42x24x TP N 72x24x TP N 42x30x TP N 42x36x TP N 30x24x TP N 48x24x TP N 36x30x TP N 48x30x TP N 48x36x TP N 48x36x TP N 60x36x TP N 60x36x TP N 72x30x TP N 16x12x TP N 72x24x TP N 20x16x TP N 72x30x TP 62 35
36 NEM 12 DOULE DOOR ENCLOSURES Type 4 & 12 ustin NEM 12 double door enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Overlapping doors eliminate need for centerpost. n -6 three point lever handle with roller arms holds doors securely. 12" legs are welded to enclosure. Heavy duty lifting eyes. Heavy gauge continuous hinge. Neoprene gasket attached to doors with oil resistant adhesive. Standard plastic self-adhesive print pocket. Standard collar studs provided for mounting optional panel. LIFTING EYES 1.25 C X PNEL Finish: ustin double door NEM 12 enclosures are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white. Y Y Options: " LEGS X Special materials. Special finishes. Custom box size or construction. PNEL (Optional) - 4" - 4" CONTINUOUS HINGE CONTINUOUS 1.38 HINGE GSKET -6 HNDLE -7 w/lock (Optional) 3/8-16 COLLR STUD GSKET SECTIO 3/8-16 COLLR STUD SECTION X-X SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 UL 508 Type 12 NEM Type 12 CUL Type 12
37 NEM 12 DOULE DOOR ENCLOSURES Catalog Enclosure Weight Panel Catalog Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number Number Size (xxc) Number Type 4 & ND 54x42x DP ND 60x48x DP ND 60x48x DP ND 60x60x DP ND 72x60x DP ND 60x48x DP ND 72x72x DP ND 60x60x DP ND 72x60x DP ND 60x48x DP ND 72x72x DP ND 72x60x DP ND 72x72x DP ND 60x48x DP ND 60x48x DP ND 60x60x DP ND 60x60x DP ND 72x60x DP ND 72x60x DP ND 72x72x DP ND 72x72x DP 37
38 NEM 12 FLUSH MOUNT ENCLOSURES Type 4 & 12 ustin flush NEM 12 enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and noncorrosive liquids. Construction: Finish: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to door with oil resistant adhesive Continuous hinge on one side and screws on opposite side to hold door in place. 10 gauge trim around enclosure. Standard plastic self-adhesive print pocket. Standard collar studs for mounting optional panel. ustin flush NEM 12 enclosures are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white. Options: Special materials. Special finishes. Custom box size or construction. Y Y C+1.06 C PNEL (Optional) 1.25 CONTINUOUS HINGE GSKET C C SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 UL 508 Type 12 NEM Type 12 CUL Type 12
39 NEM 12 FLUSH ENCLOSURES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number Type 4 & FN 16x12x TP FN 20x16x TP FN 20x20x TP FN 24x20x TP FN 24x24x TP FN 30x24x TP FN 36x24x TP FN 36x30x TP 39
40 NEM 12 LUMINUM ENCLOSURES Type 4 & 12 ustin NEM 12 aluminum enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and noncorrosive liquids. Construction: Finish: Fabricated in accordance with UL specifications from 5052-H32 aluminum. Continuously welded seams ground smooth. luminum continuous hinge. Neoprene gasket attached to door with oil resistant adhesive. Hasp and staple provided for padlocking. External feet for mounting enclosure. Standard plastic self-adhesive print pocket. Standard collar studs for mounting optional panel. ustin NEM 12 aluminum enclosures are provided standard in 5052-H32 aluminum. Optional steel panels are painted white. luminum panels are unpainted. Options: Custom box size or construction. * THIS DIMENSION IS 1.50" WHEN "" IS LESS THN 16.00" * 3.00* 1.06 C X.43 DI. Y Y PNEL (Optional) PDLOCK TYPE HSP OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31.00" (TYP).63 X SECTION X-X CONTINUOUS HINGE GSKET /8-16 COLLR STUD 1.00 SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 UL 508 Type 12 NEM Type 12 CUL Type 12
41 NEM 12 LUMINUM ENCLOSURES Catalog Enclosure Weight Steel Panel Number Size (xxc) Catalog Number N 16x12x TP N 20x16x TP N 20x20x TP N 24x20x TP Type 4 & N 24x24x TP N 30x24x TP N 36x24x TP N 36x30x TP N 48x36x TP N 20x16x TP N 24x20x TP N 30x24x TP N 36x30x TP N 60x36x TP *Optional aluminum panels are available 41
42 NEM 12 SINGLE DOOR FREESTNDING ENCLOSURES Type 4 & 12 ustin freestanding single door NEM 12 enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to door with oil resistant adhesive. n -6 three point lever handle with roller arms holds door securely. Heavy gauge continuous hinge. Heavy duty lifting eyes. Standard plastic self-adhesive print pocket. Mounting channels welded horizontally to enclosure interior sides at top, bottom, and center for optional panel. Finish: ustin freestanding single door NEM 12 enclosures are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white. Options: Special materials. Special finishes. Custom box size or construction. LIFTING EYES 1.25 C X 3" PNEL (Optional) Y Y 7" X SECTION X-X 1.25 CONTINUOUS HINGE GSKET -6 HNDLE -7 w/lock (Optional) 1.38 SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 UL 508 Type 12 NEM Type 12 CUL Type 12
43 NEM 12 SINGLE DOOR FREESTNDING ENCLOSURES Catalog Enclosure Weight Panel Catalog Weight Number Size (xxc) Number FSN 72x24x FTP FSN 72x30x FTP FSN 72x36x FTP 98 Type 4 & FSN 90x36x FTP FSN 72x24x FTP FSN 72x30x FTP FSN 72x36x FTP FSN 90x36x FTP FSN 72x24x FTP FSN 72x36x FTP FSN 72x24x FTP FSN 72x36x FTP FSN 90x36x FTP
44 NEM 12 DOULE DOOR FREESTNDING ENCLOSURES Type 4 & 12 ustin freestanding double door NEM 12 enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, terminals, and instruments. They provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: Finish: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Overlapping doors eliminate need for centerpost. Neoprene gasket attached to door with oil resistant adhesive. n -6 three point lever handle with roller arms holds doors securely. Heavy gauge continuous hinge. Heavy duty lifting eyes. Standard plastic self-adhesive print pocket. Mounting channels welded horizontally to enclosure interior sides at top, bottom, and center for optional panel. ustin freestanding double door NEM 12 enclosures are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white. Options: Special materials. Special finishes. Custom box size or construction. LIFTING EYES 1.25 C X 3" Y Y PNEL (Optional) " X SECTION X-X CONTINUOUS HINGE -6 HNDLE -7 w/lock (Optional) GSKET SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 UL 508 Type 12 NEM Type 12 CUL Type 12
45 NEM 12 DOULE DOOR FREESTNDING ENCLOSURES Catalog Enclosure Weight Panel Catalog Weight Number Size (xxc) Number Type 4 & FSND 72x48x FTP FSND 72x60x FTP FSND 72x72x FTP FSND 90x72x FTP FSND 72x48x FTP FSND 72x60x FTP FSND 72x72x FTP FSND 90x72x FTP FSND 72x60x FTP FSND 90x72x FTP
46 NEM 12 DOULE DOOR WLL MOUNT ENCLOSURES Type 4 & 12 ustin double door NEM 12 wall mount enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, instruments, and components. They provide a degree of protection against circulating dust, falling dirt, and noncorrosive liquids. Construction: Finish: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. n -6 three point lever handle with roller arms holds doors securely. Neoprene gasket attached to door with oil resistant adhesive. Overlapping doors eliminate need for centerpost. Heavy gauge continuous hinge. Standard plastic self-adhesive print pocket. External mounting feet. Standard collar studs for mounting optional panel. ustin double door NEM 12 wall mount enclosures are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white. Options: Special materials. Special finishes. Custom box size or construction. CENTER MOUNTING FEET NOT ON ENCLOSURES WITH "" LESS THN 48".43 DI C X Y Y X PNEL (Optional) CONTINUOUS HINGE GSKET -6 HNDLE -7 w/lock (Optional) /8-16 COLLR STUD OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31" SECTION Y-Y SECTION X-X INDUSTRY STNDRDS UL 50 Type 12 UL 508 Type 12 NEM Type 12 CUL Type 12
47 NEM 12 DOULE DOOR WLL MOUNT ENCLOSURES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number Type 4 & WDN 24x42x TP WDN 24x48x TP WDN 30x42x TP WDN 30x48x TP WDN 30x60x TP WDN 36x42x TP WDN 36x48x TP WDN 36x60x TP WDN 42x60x TP 47
48 TYPE 12 SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS Construction: 14 gauge steel. Flange-Mounted Disconnect Seams are continuously welded and ground smooth. External mounting feet. Door and body stiffeners in larger enclosures for rigidity. Formed lip around all sides of enclosure opening excludes liquids and contaminants. Door removable by pulling continuous hinge pin. Print pocket included. Oil-resistant gasket. 3/8-16 threaded collar studs provided for mounting optional panel. Holes in body and door for mounting operating handle, operating mechanism, and door closing mechanism. Cover interlock bracket welded to door. Furnished with door latch bar for door hardware. (disconnect switch, operating handle, operating mechanism, and door hardware are not furnished with the enclosure. They must be ordered separately from the disconnect manufacturer.) Finish: NSI 61 gray polyester powder paint outside and inside. Optional panels are painted white polyester powder. under 40" height require 2-point door hardware. 40" high and taller require 3-point door hardware. INDUSTRY STNDRDS UL 508 Type 12 CUL Type 12 NEM Type 12
49 SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS DI C X OMIT TWO MIDDLE STUDS IF "" IS LESS THN 32" STIFFENER Flange-Mounted Disconnect S S PNEL (ORDERED SEPRTELY) /8 OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31" DOOR STIFFENER X SECTION X-X MOUNTING FEET CONTINUOUS HINGE DOOR STIFFENER /8-16 COLLR STUD NEOPRENE GSKET 2.75 SPCE OCCUPIED Y DISCONNECT MOUNTING FEET ODY STIFFENER SECTION S-S PNEL (ORDERED SEPRTELY) NOTE: D = 4.75 WHEN C = 8.00 D = 7.09 WHEN C = D = WHEN C = D = WHEN C = W = WIRING SPCE 1.50 W D TOP HOLE IN R.H. FLNGE LC THIS SPCE IS OCCUPIED Y DISCONNECT SWITCH ND FUSE CLIP (IF USED) OR CIRCUIT REKER E 1.59 F
50 TYPE 12 SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS ustin Type 12 and Type 13 single door enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. Flange-Mounted Disconnect llen-radley ulletin 1494V disconnect switches with flange-mounted variable depth operating mechanisms and ulletin 1494V flange-mounted variable depth operating mechanisms for circuit breakers. (These enclosures will not accept llen-radley ulletin 1494F disconnect devices or ulletin 1494D circuit breaker operators.) Cutler-Hammer/Westinghouse Type C361 flange-mounted variable depth operating mechanisms with disconnect switches and Type C371 flange-mounted variable depth operating mechanisms for circuit breakers. General Electric Type STD flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. I-T-E Max-Flex flange-mounted variable depth operating handle for disconnect switches and circuit breakers. Square D Class 9422 disconnect switches with flange-mounted variable depth operating mechanisms and Class 9422 flange-mounted variable depth operating mechanisms for circuit breakers. (These enclosures will not accept Square D Class 9422 bracket-mounted disconnect devices.) Catalog Enclosure Size Panel Catalog Panel Size Print Stiffener Number xxc Number Ht. X Wd. Pocket Door/ody N/DSC 20x21.38x8-2020TP 17x17 Small N/DSC 24x21.38x8-2420TP 21x17 Small N/DSC 24x25.38x8-2424TP 21x21 Small N/DSC 30x21.38x8-3020TP 27x17 Small N/DSC 30x25.38x8-3024TP 27x21 Large N/DSC 36x25.38x8-3624TP 33x21 Large N/DSC 36x31.38x8-3630TP 33x27 Large N/DSC 42x31.38x8-4230TP 39x27 Small N/DSC 42x37.38x8-4236TP 39x33 Large N/DSC 48x37.38x8-4836TP 45x33 Large N/DSC 60x37.38x8-6036TP 57x33 Large N/DSC 20x21.38x TP 17x17 Small N/DSC 24x21.38x TP 21x17 Small N/DSC 24x25.38x TP 21x21 Small N/DSC 30x21.38x TP 27x17 Small N/DSC 30x25.38x TP 27x21 Large N/DSC 36x25.38x TP 33x21 Large N/DSC 36x31.38x TP 33x27 Large N/DSC 42x31.38x TP 39x27 Small N/DSC 42x37.38x TP 39x33 Large N/DSC 48x37.38x TP 45x33 Large N/DSC 60x37.38x TP 57x33 Large N/DSC 30x25.38x TP 27x21 Large N/DSC 36x31.38x TP 33x27 Large N/DSC 42x31.38x TP 39x27 Small N/DSC 42x37.38x TP 39x33 Large N/DSC 48x37.38x TP 45x33 Large N/DSC 60x37.38x TP 57x33 Large N/DSC 36x31.38x TP 33x27 Large N/DSC 48x37.38x TP 45x33 Large N/DSC 60x37.38x TP 57x33 Large 1 1 INDUSTRY STNDRDS UL 508 Type 12 CUL Type 12 NEM Type 12
51 Disconnect Ordering Information: When ordering wall-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. llen-radley General Electric When using a ulletin 1494F flange-mounted disconnect switch, order: When using a disconnect switch, order: disconnect switch with operating mechanism (ulletin 1494V) disconnect switch (Type QMR or QMW) ulletin 1494V-H1 operating handle fuse clip or no-fuse kit connecting rod [ulletin 1494V-R1 for 8" and 10" deep enclosures; flange handle (STD1 or STD2) ulletin 1494V-R2 for 12" and 16" deep enclosures] variable depth operating mechanism trailer fuse block kit, if required (ulletin 1494V) Door hardware (TDV1 for 2-point latching or TDV1 and TDV3 fuse clip kit, if required for 3-point latching) Line and load connectors, if required Door hardware (ulletin 1494V-L1 for 2-point latching or ulletin When using a circuit breaker with a Spectra Flex cable operator, order: 1494V-L1 and 1494V-L2 for 3-point latching) circuit breaker flange-mounted handle mechanism When using a ulletin 1494V circuit breaker operating mechanism, order: breaker-mounted mechanism circuit breaker (C-H/Westinghouse) n operating cable circuit breaker operating mechanism (ulletin 1494V) Door hardware (TDV1 for 2-point latching or TDV1 and TDV3 for n operating handle (ulletin 1494V-H11) 3-point latching) connecting rod [ulletin 1494V-R1 for 8" and 10" deep enclosures or ulletin 1494V-R2 for 12" and 16" deep enclosures] When using a circuit breaker, order: Door hardware (ulletin 1494V-L1 for 2-point latching, or ulletin circuit breaker 1494V-L1 and 1494V-L2 for 3-point latching) flange handle (STD1 or STD2) variable depth operating mechanism Controls Door hardware (TDV1 for 2-point latching or TDV1 and TDV3 for When using a disconnect switch, order: 3-point latching) flange operated switch (fusible or non-fusible) shaft [DSFHS-12 for 8", 10", and 12" deep enclosures or DSFHS-17 I-T-E Siemens for 16 deep enclosures] When using a disconnect switch, order: handle (DSFGN-HS12) basic switch (right hand) Door hardware (FH-DHK for 2-point latching or FH-DHK and FH-3RL fuse or no-fuse kit for 3-point latching) FHOHS flange-mounted handle Switch operator When using a circuit breaker, order: Cable, 36" circuit breaker () Door hardware (DKR2 for 2-point latching or DKR3 for 3-point latching) n operating mechanism shaft [FHS-12 for 8", 10", and 12" deep enclosures or FHS-17 for When using a circuit breaker, order: 16 deep enclosures] circuit breaker handle mechanism (FHN-HS12) Pressure wire connectors Door hardware (FH-DHK for 2-point latching or FH-DHK and FH-3RL FHOH flange-mounted handle for 3-point latching) circuit breaker operator mechanism n operating cable (standard 36" for 125 amp to 600 amp circuit breakers Cutler-Hammer/Westinghouse and 48" for 800 amp to 1200 amp circuit breakers) When using a Type C361 disconnect switch, order: Door hardware (DKR2 for 2-point latching or DKR3 for 3-point latching) disconnect switch with an operating mechanism n operating handle (C361H1 or C361H3) Square D Door hardware (C361KJ4 or C361KJ6 and C361KR for 3-point latching) When using a Class 9422 disconnect switch, order: disconnect switch with operating mechanism (Class 9422) When using a Type C371 circuit breaker operating mechanism with a handle mechanism (Class 9422 Type -1) C-H/Westinghouse circuit breaker, order: door closing mechanism (Class 9423 Type M4 for 2-point latching, or circuit breaker Class 9423 Type M9 or M4 and Class 9423 Type M3 for 3-point latching) n operating mechanism n operating handle When using a circuit breaker, order: Door hardware (C361KJ4 or C361KJ6 for 2-point latching, C361KJ4 or circuit breaker (Square D) C361KJ6 and C361KR for 3-point latching) n operating mechanism (Class 9422) handle mechanism (Class 9423 Type M4 for 2-point latching, or When using a C-H/Westinghouse circuit breaker with a Flex Shaft Class Type M9 or M4 and Class 9423 Type M3 for 3-point latching) handle mechanism, order: circuit breaker When using a Class 9422 Type T disconnect switch with a cable complete Flex Shaft handle mechanism mechanism, order: Door hardware (C361KJ4 or C361KJ6 for 2-point latching, C361KJ4 disconnect switch with operating mechanism (Class 9422, Type T) or C361KJ6 and C361KR for 3-point latching) handle mechanism (Class 9422 Type -1) cable mechanism (Class 9422 CFT_O) 3-, 5-, or 10-foot door closing mechanism (Class 9423 Type M4 for 2-point latching, or Class 9423 Type M9 or M4 and Class 9423 Type M3 for 3-point latching) Flange-Mounted Disconnect When using a circuit breaker with a cable mechanism, order: circuit breaker (Square D) handle mechanism (Class 9422 Type -1) cable mechanism (Class 9422 CFT_O) 3-, 5-, or 10-foot door closing mechanism (Class 9423 Type M4 for 2-point latching, or Class 9423 Type M9 or M4 and Class 9423 Type M3 for 3-point latching) 51
52 TYPE 4, 4X SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS Construction: Flange-Mounted Disconnect Finish: Type 4 enclosures are painted NSI 61 gray polyester powder outside and inside. Type 4X enclosures are unpainted. Optional panels are painted white polyester powder. INDUSTRY STNDRDS Steel UL 508 Types 4 & 12 CUL Types 4 & 12 NEM Types 4, 12, & 3 14 gauge steel or 14 gauge Type 304 stainless steel. Seams are continuously welded and ground smooth. External mounting feet. Door and body stiffeners in larger enclosures for rigidity. Formed lip around all sides of enclosure opening excludes liquids and contaminants. Stainless steel exterior hardware. Stainless steel door clamps on three sides of door provide a watertight seal. Door removable by pulling continuous hinge pin. Print pocket included. Oil-resistant gasket. 3/8-16 threaded collar studs provided for mounting optional panel. Holes in body for mounting disconnect operating handle and operating mechanism Cover interlock bracket welded to door. Disconnect switch, operating handle, and operating mechanism are not furnished with the enclosure. They must be ordered separately from the disconnect manufacturer. Stainless Steel UL 508 Types 4X, 4, & 12 CUL Types 4X, 4, & 12 NEM Types 4X, 4, 12, & 3
53 SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS.62 S DI. S 3.00 C X OMIT TWO MIDDLE STUDS IF "" IS LESS THN 32" STIFFENER PNEL (ORDERED SEPRTELY) Flange-Mounted Disconnect DOOR CLMP -4 3/8 OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31" DOOR STIFFENER X SECTION X-X MOUNTING FEET CONTINUOUS HINGE DOOR STIFFENER 1.38 NEOPRENE GSKET 3/8-16 COLLR STUD 2.75 SPCE OCCUPIED Y DISCONNECT MOUNTING FEET ODY STIFFENER SECTION S-S PNEL (ORDERED SEPRTELY) NOTE: D = 8.62 WHEN C = 8.00 D = WHEN C = W = WIRING SPCE 1.50 W D TOP HOLE IN R.H. FLNGE LC E THIS SPCE IS OCCUPIED Y DISCONNECT SWITCH ND FUSE CLIP (IF USED) OR CIRCUIT REKER 1.59 F
54 TYPE 4, 4X SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS ustin Type 4 and Type 4X single door enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: Flange-Mounted Disconnect Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. llen-radley ulletin 1494V disconnect switches with flange-mounted variable depth operating mechanisms and ulletin 1494V flange-mounted variable depth operating mechanisms for circuit breakers. (These enclosures will not accept llen-radley ulletin 1494F disconnect devices ulletin 1494D circuit breaker operators.) or Cutler-Hammer/Westinghouse Type C361 flange-mounted variable depth operating mechanisms with disconnect switches and Type C371 flange-mounted variable depth operating mechanisms for circuit breakers. General Electric Type STD flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. I-T-E Max-Flex flange-mounted variable depth operating handle for disconnect switches and circuit breakers. Square D Class 9422 disconnect switches with flange-mounted variable depth operating mechanisms and Class 9422 flange-mounted variable depth operating mechanisms for circuit breakers. (These enclosures will not accept Square D Class 9422 bracket-mounted disconnect devices.) Catalog Stainless Steel Enclosure Size Panel Catalog Panel Size Print No. of Stiffener Number Catalog Number xxc Number Ht.xWd. Pocket Clamps Door/ody NF/DSC NFX/DSC 24x21.38x8-2420TP 21x17 Small NF/DSC NFX/DSC 24x25.38x8-2424TP 21x21 Small NF/DSC NFX/DSC 30x25.38x8-3024TP 27x21 Large NF/DSC NFX/DSC 36x25.38x8-3624TP 33x21 Large NF/DSC NFX/DSC 36X31.38X8-3630TP 33x27 Large NF/DSC NFX/DSC 42x31.38x TP 39x27 Small NF/DSC NFX/DSC 42x37.38x TP 39x33 Large NF/DSC NFX/DSC 48x37.38x TP 45x33 Large NF/DSC NFX/DSC 60x37.38x TP 57x33 Large
55 DISCONNECT ORDERING INFORMTION When ordering wall-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. llen-radley General Electric When using a ulletin 1494V disconnect switch, order: When using a disconnect switch, order: disconnect switch with operating mechanism (ulletin 1494V) disconnect switch (QMR or QMW) n operating handle (ulletin 1494V-W1) fuse clip kit or no-fuse kit connecting rod [ulletin 1494V-R1 for 8 deep enclosures; flange handle (STD1X) ulletin 1494V-R2 for 12" deep enclosures] variable depth operating mechanism trailer fuse block kit, if required (ulletin 1494V) fuse clip kit, if required When using a circuit breaker, order: Line and load connectors, if required circuit breaker flange handle (STD1X) When using a ulletin 1494V circuit breaker operating mechanism, order: variable depth operating mechanism circuit breaker (C-H/Westinghouse) circuit breaker operating mechanism (ulletin 1494V) When using a circuit breaker with a Spectra Flex cable operator, order: n operating handle (ulletin 1494V-W11) circuit breaker connecting rod [ulletin 1494V-R1 for 8" deep enclosures; ulletin flange-mounted handle mechanism 1494V-R2 for 12" deep enclosures] breaker-mounted mechanism n operating cable Controls When using a disconnect switch, order: I-T-E Siemens flange-operated switch (fusible or non-fusible) When using a disconnect switch, order: shaft (DSFHS-12) basic switch (right hand) handle (DSFHN-HS4) fuse or non-fuse kit flange-mounted handle (FHOHS4) When using a circuit breaker, order: Switch operator circuit breaker () Cable, 36' n operating mechanism shaft (FHS-12) When using a circuit breaker, order: handle (FHN-HS4) circuit breaker Pressure wire connectors Cutler-Hammer/Westinghouse flange-mounted handle (FHOHS4) When using a Type C361 disconnect switch, order: circuit breaker operator mechanism disconnect switch with an operating mechanism n operating cable (standard 36") n operating handle (C361H2 or C361H4) Square D When using a Type C371 circuit breaker operating mechanism with a When using a Class 9422 disconnect switch, order: C-H/Westinghouse circuit breaker, order: disconnect switch with operating mechanism (Class 9422) circuit breaker handle mechanism (Class 9422 Type -2 or -1) n operating mechanism n operating handle (C371H2 or C371H4) When using a circuit breaker, order: circuit breaker (Square D) When using a C-H/Westinghouse circuit breaker with Type 4/4X Flex n operating mechanism (Class 9422) Shaft handle mechanism, order: handle mechanism (Class 9422 Type -2 or -1) circuit breaker complete Flex Shaft handle mechanism When using a Class 9422 Type T disconnect switch with a cable mechanism, order: disconnect switch with operating mechanism (Class 9422, Type T) handle mechanism (Class 9422 Type -1) cable mechanism (Class 9422 CFT-O) 3-, 5-, or 10-foot Flange-Mounted Disconnect When using a circuit breaker with a cable mechanism, order: circuit breaker handle mechanism (Class 9422 Type -1) cable mechanism (Class 9422 CFT_O) 3-, 5-, or 10-foot 55
56 TYPE 4, 4X, 12 SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS Wire end Space bove Disconnect Flange-Mounted Disconnect llen-radley ulletin 1494V Disconnects Type 12 Type 4 & 12 When When When When When Type mp Fuse Fuse Space Occupied C = 8 C = 10 C = 12 or 16 C = 8 C = 12 Number Rating Clip Class E F* W W W W W DS30 30 NO FUSE N DS V H,K,R DS V H,K,R DS V J DS V H,K DS V H,K DS V J DS60 60 NO FUSE N DS V H,K,R DS V H,K,R DS V J DS V H,K,R DS V H,K DS V H,K DS V J DS100** 100 NO FUSE N N DS100** V H,K,R N DS100** V H,K,R N DS100** V J N DS100** V H,K,R N DS100** V J N DS200** 200 NO FUSE N N N 8.12 N 8.12 DS200** V H,K,R N N 8.12 N 8.12 DS200** V H,K,R N N 8.12 N 8.12 DS200** V J N N 8.12 N 8.12 DS200** V H,K,R N N 8.12 N 8.12 DS200** V J N N 8.12 N 8.12 M Westinghouse N Circuit reakers EHD, FD, FD FDC, HFD, HMCP M Westinghouse N N N N Circuit reakers JD, JD, JDC, HJD, HMCP M Westinghouse N N N N Circuit reakers KD, KD, KDC HKD, HMCP *Does not include space for optional auxiliary switch **Series.
57 DISCONNECT WIRING SPCE INFORMTION Wire end Space bove Disconnect Controls Disconnect Switches with Flange-Mounted Operators Type 12 Type 4 & 12 When When When When When Switch mp Fuse Fuse Space Occupied C = 8 C = 10 C = 12 or 16 C = 8 C = 12 Number Rating Clip Class E F W W W W W Flange-Mounted Disconnect OETL-NF30-F 40 NO FUSE N OETL-NF60-F 80 NO FUSE N OETL-NF100-F 100 NO FUSE N OETL-NF175-F 175 NO FUSE N N OETL-NF200-F 200 NO FUSE N N OES-F30J6-F V J OES-F60J6-F V J OES-F100J6-F V J Wire end Space bove Disconnect Controls Circuit reakers with Flange-Mounted Operators Type 12 Type 4 & 12 When When When When When Mechanism mp Frame Space Occupied C = 8 C = 10 C = 12 or 16 C = 8 C = 12 Rating Type E F W W W W W FHD-M 150 D FHF-M E/Q FHF-M 225 F FHJ-M 400 J N N 8.77 N 8.77 FHM-M 600 L N N 8.28 N 8.28 FHM-M 800 M N N 7.87 N
58 TYPE 4, 4X, 12 SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS Wire end Space bove Disconnect Flange-Mounted Disconnect Cutler-Hammer C361 Disconnect Switches Type 12 Type 4 & 12 When When When When When Switch Type mp Fuse Fuse Space Occupied C = 8 C = 10 C = 12 or 16 C = 8 C = 12 Number Number Rating Clip Class E F W W W W W C361 NC 30 NO FUSE N C361 SC V H,K,R C361 SC V H,K,R C361 SC V H,J,K,R C361 ND 60 NO FUSE N C361 SD V H,K,R C361 SD V J C361 SD V H,K,R C361 SD V J C361 NE 100 NO FUSE N C361 SE V H,K,R C361 SE V H,K,R C361 SE V J C361 NF* 200 NO FUSE N N N C361 SF264* V H,K,R N N C361 SF264* V H,J,K,R N N Wire end Space bove Disconnect Cutler-Hammer C371 Circuit reaker Operators for C-H / Westinghouse Circuit reakers Type 12 Type 4 & 12 When When When When When Mechanism Max mp Frame Space Occupied C = 8 C = 10 C = 12 or 16 C = 8 C = 12 Rating Type E F W W W W W C371E 225 F-Frame: EHD, FD, FD, HFD, FDC C371E 150 F-Frame: HMCP C371F 250 J Frame: JD, JD, HJD, JDC N N C371F 250 J Frame: HCMP N N C371F 400 K Frame: DK, KD, KD, HKD N N N C371F 400 K Frame: HMCP N N N C371G 600 L Frame: LD, HLD, LDC N N 9.18 N 9.18 C371G 600 L Frame: HMCP N N 9.18 N 9.18
59 DISCONNECT WIRING SPCE INFORMTION Cutler-Hammer Flex Shaft Operator Mechanisms for C-H/Westinghouse Circuit reakers Complete Operator mp Frame reaker reaker Mechanism Rating Type Height Width F1S F-Frame/EHD, FD, FD, HFD, FDC F1S F-Frame HMCP F2S J-Frame/JD, JD, HJD, JDC F2S J-Frame HMCP F3S K-Frame/DK, KD, KD, HKD F3S K-Frame HMCP F4S L-Frame/LD, HLD, LDC F4S L-Frame HMCP Flange-Mounted Disconnect F7S M-Frame/MD, MDS F5S N-Frame/ND, HND, NDC F6S R-Frame/RD, CRD, RDC Catalog numbers for complete mechanisms include a flange-mounted handle, flexible shaft and circuit breaker mechanism. -The last digit of the catalog number denotes the length of shaft (F1S03 = 3 foot shaft). The F, J, K frame Flex Shafts are available in 3-foot to 10-foot lengths. The L, N, R frame Flex Shafts are available in 4-foot to 6-foot lengths. Space Occupied by Disconnect *The Flex Shaft system allows the circuit breaker to be positioned independent from the flange-mounted handle mechanism. *Refer to National Electrical Code 1999, article (b) for wiring space "W" required for line side conductors. *Choose the length of shaft based on placement of the circuit breaker in the enclosure ensuring a 4" minimum bending radius for the Flex Shaft. *Space occupied by circuit breaker is determined by overall height "X", width "Y", wire bend space "W" and location "F" as selected from right to left. Wire end Space bove Disconnect General Electric Type STD Operators for Disconnects Type 12 Type 4 & 12 When When When When When Mechanism mp Fuse Fuse Space Occupied C = 8 C = 10 C = 12 or 16 C = 8 C = 12 Rating Clip Class E F W W W W W TD0M1 30 NO FUSE N 7.75** * TD0M V H,R 7.75** * TD0M V H,R 12.38** * TD0M V H,R 12.38** * TD0M V H,R 12.38** * TD0M1 60 NO FUSE N 7.75** * TD0M V H,R 12.38** * TD0M V H,R 12.38** * TD0M V H,R 12.38** * TD0M V H,R 12.38** * TD0M1 100 NO FUSE N 7.75** * TD0M V H,R 12.38** * TD0M V H,R 12.38** * TD0M V H,R 12.38** * TD0M V H,R 12.38** * TD0M2 200 NO FUSE N N N TD0M V H,R N N TD0M V H,R N N *Disconnect moved down.88" to fit on panel **Dimension applies to 8" deep enclosures and is.88" less in deeper enclosures 59
60 TYPE 4, 4X, 12 SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS Wire end Space bove Disconnect General Electric Type STD Operators for Circuit reakers Type 12 Type 4 & 12 When When When When When Mechanism mp Frame Space Occupied C = 8 C = 10 C = 12 or 16 C = 8 C = 12 Rating Type E F W W W W W Flange-Mounted Disconnect SD0M1 150 TE, TED, THED 7.75** * SD0M1 150 TEC 7.75** * TD0M1 150 T ** * TD0M1 150 TEC, TECL 12.38** * TD0M1C 150 TEL 7.75** * TD0M1D 150 THLC1 7.75** 5.25 N TD0M3 225 TFJ N TD0M3 225 TFK, THFK, TFL N TD0M4 400 TJJ, TJK4, THJK4, TJL4V N TD0M4 600 TJK6, THJK6, TJ4V, TJL4V N TD0M5 400 T4, TJH6S N TD0M6 225 TL2, THLC N N TD0M6 400 TL4, THLC N N SD0M1 150 SPECTR SE ** * SD0M3 250 SPECTR SF N SD0M4 600 SPECTR SG N N 7.93 N 7.93 *Disconnect moved down.88" to fit on panel. **Dimension applies to 8" deep enclosures and is.88" less in deeper enclosures. General Electric Circuit reakers with Spectra Flex Cable Operators Frame Max mp Circuit reaker Circuit reaker Size Rating Height Width "X" "Y" E SE SF SG SK See enclosure size tables for enclosures that will accept these devices Frame reaker Flange-Mounted Operating Size Mechanism Handle Cable E150 SC0M1 SCH1 SC3L SE150/SF250 SC0M1EF SCH1 SC3L SG600 SC0M1G SCH1 SC3L SK1200 SC0M1K SCH2K SC3H *Operating cables are available in 3-foot to 10-foot lengths. (The number 3 in the catalog number denotes 3-foot cable.) **dd "X" for NEM 4 or 4X flange mounted handle. Space Occupied by Circuit reaker -The General Electric Spectra-Flex cable operators allow a circuit breaker to be positioned independent from the flange-mounted handle mechanism. -Refer to National Electrical Code 1999 article (b) for wiring space "W" required for line side conductors. -Choose the operating cable length based on placement of circuit breaker in the enclosure ensuring a 3" minimum bending radius for the cable. -Space occupied by circuit breaker is determined by overall circuit breaker size ("X" heigth and "Y" width) plus "W" wire bend space and location "F" from right to left as selected.
61 DISCONNECT WIRING SPCE INFORMTION I-T-E Disconnect Switches for Max-Flex Operators Switch mp Fuse Fuse Disconnect Disconnect Rating Clip Class Height Width "X" "Y" MCS603R 30 NO FUSE N MCS603R V H,K,R MCS603R V H,K,R MCS603R V J MCS606R 60 NO FUSE N MCS606R V H,K,R MCS606R V H,K,R MCS606R V J Flange-Mounted Disconnect MCS610R 100 NO FUSE N MCS610R V H,K,R MCS610R V H,K,R MCS610R V J MCS620R 200 NO FUSE N MCS620R V H,K,R MCS620R V H,K,R MCS620R V J See enclosure size table for enclosures that accept these devices I-T-E Circuit reakers with Max-Flex Operators Complete (1) (2) Circuit Maximum Circuit Circuit Circuit Operator reaker mp reaker reaker reaker Mechanism Frame Rating Height Width Type "X" "Y" FH0E036 ED ED2, ED4, ED6, HED4, HED6 FH0E36 CED CED6 FH0F036 FD FXD6-, FD6-, HFD6. FXD6-ETJ, HHFD6, HHFXD6 FH0J036 CFD CFD6, CFD6-ETI FH0J036 JD JXD2, JXD6, JD6, HJD6, HHJD6, HHJXD6, JXD6-ETI FH0J036 CJD CJD6, CJD6-ETI FH0J036 LD LXD6, LD6, HLD6, HHLD6, HHLDX6, LXD6-ETI FH0J036 CLD CLD6, CLD6-ETI FH0LM036 LMD LMD6, LMXD6, HLMD6, HLMXD6, LMXD6-ETI. 1)The last 3 digits of operator mechanism number indicate cable length in inches. 48" cables are available for ED, FD, JD/LD operators and 60" cables for MD/ND, PD/RD operators 2) For Type 4 applications order handle, cable and circuit breaker operator separately. Space Occupied by Disconnect -The I-T-E Max-Flex cable system allows the disconnect to be positioned independent from the flange-mounted handle operator.. -Refer to National Electrical Code 1999 article (b) for wiring space "W" required for line side conductors. -Refer to Siemens I-T-E installation instructions for limits on disconnect location when using 36" or 48" Max-Flex cables -Space occupied by disconnect is determined by overall disconnect height "X", width "Y", wire bend space "W", and location "F" as selected from right to left. 61
62 TYPE 4, 4X, 12 SINGLE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS Square D Class 9422 Disconnect Switches used with Cable Mechanism 9422-CFT30* and Handle Mechanism Flange-Mounted Disconnect Switch mp Fuse Fuse Disconnect Disconnect Rating Clip Class Height Width "X" "Y" TCN NO FUSE N TCF V H,K,R TCF V H,K,R TCF V H,K,R TCF V J TDN NO FUSE N TDF V H,K,R TDF V H,K,R TDF V H,K,R TDF V J TEN NO FUSE N TEF V H,K,R TEF V H,K,R TEF V J See enclosure size table for enclosures that accept these devices. *Use switch with appropriate cable mechanism and handle mechanism. Square D Class 9422 Cable Mechanisms for Circuit reakers Cable Type* mp Frame Circuit reaker Circuit reaker Switch Rating Type Height Width "X" "Y" 9422 CGJ30 75 GJL CEJ GJL CF FL, FHL CK KL, KHL CL LL, LHL, Q4L See enclosure size table for enclosures that accept these devices. Use cable mechanism with appropriate circuit breaker and handle mechanism. *Cable operators are available in 3, 5, and 10 foot lengths. Numbers shown (30) are for 3 foot cables. Space Occupied by Disconnect Switch or Circuit reaker -Square D cable mechansims allow disconnect device to be positioned independent from the flange mounted handle mechanism. -Refer to National Electrical Code 1999 article (b) for wiring space "W" required for line side conductors. -Choose cable mechanism length based on placement of disconnect in enclosure. See Square D Instruction ulletin for minimum bend radius for cable. -Space occupied by disconnect is determined by overall disconnect ("X" height and "Y" width) plus "W" wire bend space and location "F" from right to left as selected.
63 DISCONNECT WIRING SPCE INFORMTION Wire end Space bove Disconnect Square D Class 9422 Disconnects Type 12 Type 4 & 12 When When When When When Type mp Fuse Fuse Space Occupied C = 8 C = 10 C = 12 or 16 C = 8 C = 12 Number Rating Clip Class E F W W W W W TCN NO FUSE N TCF V H,K,R TCF V H,K,R TCF V H,K,R TCF V J Flange-Mounted Disconnect TDN NO FUSE N TDF V H,K,R TDF V H,K,R TDF V H,K,R TDF V J TEN NO FUSE N N TEF V H,K,R N TEF V H,K,R N TEF V J N TC-1 30 NO FUSE N TC V H,K,R TC V H,K,R TC V H,K,R TC V J TD-1 60 NO FUSE N TD V H,K,R TD V H,K,R TD V H,K,R TD V J TE NO FUSE N N N 10.2 TE V H,K,R N N TE V H,K,R N N TE V J N N TE V J N N TF NO FUSE N N N 8.88 N 8.88 TF V H,K,R N N 8.88 N 8.88 TF V H,K,R N N 8.88 N 8.88 TF V J N N 8.88 N 8.88 TF V J N N 8.88 N 8.88 RG-1 75 GJL Circuit reaker RG GJL Circuit reaker RN FL, FHL Circuit reaker RP KL, KHL Circuit reaker * RR LL, LHL, Q4L Circuit reaker N N 7.00 N 7.00 *Not recommended except with #1 or smaller line conductors. 63
64 TYPE 12 SINGLE DOOR ENCLOSURES FOR - FLNGE-MOUNTED DISCONNECTS ustin Type 12 and Type 13 single door enclosures for llen-radley disconnects are designed to house llen-radley ulletin 1494F disconnect devices and ulletin 1494D circuit breaker operators. Construction: Flange-Mounted Disconnect 14 gauge steel. Seams are continuously welded and ground smooth. External mounting feet. Door and body stiffeners in larger enclosures for rigidity. Formed lip around all sides of enclosure opening excludes liquids and contaminants. Door removable by pulling continuous hinge pin. Print pocket included. Oil-resistant gasket. 3/8-16 threaded collar studs provided for mounting optional panel. Holes in body and door for mounting operating handle, operating mechanism, and door closing mechanism. Finish: NSI 61 gray polyester powder paint outside and inside. Optional panels are painted white polyester powder. Cover interlock bracket welded to door. Furnished with door latch bar for door hardware. (disconnect switch, operating handle, operating mechanism, and door hardware are not furnished with the enclosure. They must be ordered separately from the disconnect manufacturer.) under 40" high require 2-point door hardware. 40" high and taller require 3-point door hardware. INDUSTRY STNDRDS UL 508 Type 12 CUL Type 12 NEM Type 12
65 SINGLE DOOR ENCLOSURES FOR - FLNGE-MOUNTED DISCONNECTS.62 S DI. S 3.00 C X OMIT TWO MIDDLE STUDS IF "" IS LESS THN 32" STIFFENER PNEL (ORDERED SEPRTELY) Flange-Mounted Disconnect /8 OMIT TWO MIDDLE STUDS IF "" IS LESS THN 31" DOOR STIFFENER X SECTION X-X MOUNTING FEET CONTINUOUS HINGE DOOR STIFFENER /8-16 COLLR STUD NEOPRENE GSKET SPCE OCCUPIED Y DISCONNECT NOTE: D = 3.84 WHEN C = 8.00 D = 6.75 WHEN C = D = 9.50 WHEN C = MOUNTING FEET ODY STIFFENER PNEL (ORDERED SEPRTELY) (except enclosures for 200 amp switches) D = 9.50 WHEN C = D = WHEN C = SECTION S-S 1.50 (for enclosures with 200 amp switches) W = WIRING SPCE W D TOP HOLE IS R.H. FLNGE LC THIS SPCE IS OCCUPIED Y DISCONNECT SWITCH ND FUSE CLIP (IF USED) OR CIRCUIT REKER E 1.30 F
66 TYPE 12 SINGLE DOOR ENCLOSURES FOR - FLNGE-MOUNTED DISCONNECTS Flange-Mounted Disconnect Type 12 for llen-radley Disconnects Catalog Enclosure Size Panel Catalog Panel Size Print Stiffener Number xxc Number Ht.xWd. Pocket Door/ody N/DSC 20x21.38x8-2020TP 17x17 Small N/DSC 24x21.38x8-2420TP 21x17 Small N/DSC 24x25.38x8-2424TP 21x21 Small N/DSC 30x21.38x8-3020TP 27x17 Small N/DSC 30x25.38x8-3024TP 27x21 Large N/DSC 36x25.38x8-3624TP 33x21 Large N/DSC 36X31.38X8-3630TP 33x27 Large N/DSC 42X31.38X8-4230TP 39x27 Small N/DSC 42X37.38X8-4236TP 39x33 Large N/DSC 48X37.38X8-4836TP 45x33 Large N/DSC 24x21.38x TP 21x17 Small N/DSC 24x25.38x TP 21x21 Small N/DSC 30x21.38x TP 27x17 Small N/DSC 30x25.38x TP 27x21 Large N/DSC 36x25.38x TP 33x21 Large N/DSC 36x31.38x TP 33x27 Large N/DSC 42x31.38x TP 39x27 Small N/DSC 42x37.38x TP 39x33 Large N/DSC 48x37.38x TP 45x33 Large N/DSC 60x37.38x TP 57x33 Large N/DSC 36x31.38x TP 33x27 Large N/DSC 42x31.38x TP 39x27 Small N/DSC 42x37.38x TP 39x33 Large N/DSC 48x37.38x TP 45x33 Large N/DSC 60x37.38x TP 57x33 Large N/DSC 48x37.38x TP 45x33 Large N/DSC 60x37.38x TP 57x33 Large 1 1
67 SINGLE DOOR ENCLOSURES FOR - FLNGE-MOUNTED DISCONNECTS Disconnect Ordering Information: When using a ulletin 1494F disconnect switch, order: disconnect switch (30, 60, or 100) fuse block adapter, if required Line and load connectors, if required Door hardware (ulletin 1494F-L1 for 2-point latching, or ulletin 1494F-L2 and 1494F-L3 for 3-point latching) When using a ulletin 1494D circuit breaker operating mechanism, order: circuit breaker (C-H/Westinghouse) n operator mechanism slide mechanism Door hardware (ulletin 1494F-L1 for 2-point latching, or ulletin 1494F-L2 and 1494F-L3 for 3-point latching) Flange-Mounted Disconnect *llen-radley 1494F Disconnect Switches Wire end Space bove Disconnect When When When Enclosure Depth Type mp Fuse Fuse Space Occupied D = 3.84 D = 6.75 D = Number Rating Clip Class E F (1) W W W * * * * N30 30 NO FUSE N * * * * NF V H,K,R * * * * NF V H,K,R * * * * NF V H,K,R * * * * NF V H,K,R * * * * NF V J * * * * NF V J * * * * N60 60 NO FUSE N * * * * NF V H,K,R * * * * NF V H,K,R * * * * NF V H,K,R * * * * NF V H,K,R * * * * NF V H,K,R * * * * NF V J * * * * NF V J * * * N NO FUSE N N * * * NF V H,K,R N * * * NF V H,K,R N * * * NF V H,K,R N * * * NF V H,K,R N * * * NF V J N * * * NF V J N *llen-radley 1494D Circuit reaker Operators When When When Enclosure Depth Type Frame reaker Frame Size Space Occupied D = 3.84 D = 6.75 D = Number Rating Type (3 pole) E F W W W * * * * N4/N C-H/Westinghouse EHD, FD, FD, FDC, HFD, HMCP * * * N5/N General Electric TFC, TFK, THFK N * * * N5/N C-H/Westinghouse JD, JD, JDC, HJD, HMCP N * * * N5/N C-H/Westinghouse KD, KD, KDC, HKD, HMCP N (1) The "F" dimensions does not include space for auxiliary switches. See llen-radley instructions for additional space required. 67
68 TYPE 12 DOULE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS Construction: Flange-Mounted Disconnect 10 gauge steel. Seams continuously welded and ground smooth. ody stiffeners in larger enclosures for extra rigidity. Removable centerpost for easy installation of optional panel. Heavy gauge continuous hinge. 3-point latching mechanisms operated by padlocking handle on all doors. Heavy duty lifting eyes. Print pocket included. 15" floor stands are welded to enclosure. Oil-resistant gasket. Panel supports for optional panel. 3/8-16 threaded collar studs provided for mounting optional panel. Defeater on master door requires a screwdriver to open. Mechanical interlock operated by master door prevents slave door from being opened first. Finish: NSI 61 gray polyester powder paint outside and inside. Optional panels are painted white polyester powder. INDUSTRY STNDRDS UL 508 Type 12 NEM Type 12 CUL Type 12
69 DOULE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS C X PDLOCKLE HNDLE Flange-Mounted Disconnect / CONTINUOUS HINGE REMOVLE CENTERPOST X 2.06 W D TOP OF DISCONNECT THIS SPCE IS OCCUPIED Y DISCONNECT SWITCH ND FUSE CLIP (IF USED) OR CIRCUIT REKER E F
70 TYPE 12 DOULE DOOR ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS ustin Type 12 double door enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: Flange-Mounted Disconnect Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. llen-radley ulletin 1494F flange-mounted disconnect switches and ulletin 1494D flange-mounted operators for circuit breakers. llen-radley ulletin 1494V variable depth flange-operated disconnect switches and circuit breaker mechanisms. Cutler-Hammer/Westinghouse Type C361 disconnect switches and operator mechanisms, and Type C371 circuit breakers and circuit breaker operating mechanisms. lso Type SM safety handle mechanisms and Flex Shaft handle operators for circuit breakers. General Electric Type STD flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. lso Spectra Flex cable operators for circuit breakers. I-T-E Max-Flex flange-mounted variable depth operating handles for disconnect switches and circuit breakers. Square D disconnect switches and circuit breakers used with Class 9422 flange-mounted variable depth operating mechanisms or cable mechanisms. (These enclosures will not receive Class 9422 bracket-mounted disconnect devices, Class 9422TG1, or TG2 devices.) Catalog Enclosure Size Panel Catalog Panel Size Number xxc Number Ht. X Wd ND/FDSC 60x49.62x DP 56x ND/FDSC 60x61.62x DP 56x ND/FDSC 72x61.62x DP 68x ND/FDSC 72x73.62x DP 68x ND/FDSC 60x49.62x DP 56x ND/FDSC 60x61.62x DP 56x ND/FDSC 72x61.62x DP 68x ND/FDSC 72x73.62x DP 68x ND/FDSC 60x49.62x DP 56x ND/FDSC 60x61.62x DP 56x ND/FDSC 72x73.62x DP 68x68
71 DISCONNECT ORDERING INFORMTION When ordering floor-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. llen-radley General Electric When using a ulletin 1494F flange-mounted When ordering a disconnect switch, order: disconnect switch, order: disconnect switch (Type QMR or QMW) disconnect switch fuse clip or no-fuse kit fuse block adapter (if required) flange handle (STD1 or STD2) Line and load connector (if required) variable depth operating mechanism n extended length drive rod (if required) When using a ulletin 1494D flange-mounted operator for a circuit breaker, order: When using a circuit breaker, order: circuit breaker (C-H/Westinghouse) circuit breaker flange-mounted operator mechanism flange handle (STD1 or STD2) slide mechanism variable depth operating mechanism n extended length drive rod (if required) When using a ulletin 1494V disconnect switch, order: disconnect switch When using a circuit breaker with a Spectra Flex cable n operating handle operator, order: connecting rod (long) circuit breaker trailer fuse block kit (if required) flange-mounted handle mechanism fuse clip kit (if required) breaker-mounted mechanism Line and load connectors (if required) n operating cable Flange-Mounted Disconnect When using a ulletin 1494V circuit breaker operating I-T-E Siemens mechanism, order: When using a disconnect switch, order: circuit breaker (C-H/Westinghouse) basic switch (right-hand) circuit breaker operating mechanism fuse or no-fuse kit n operating handle FHOHS flange-mounted handle connecting rod (long) Switch operator FHOECO36 cable for 12" deep or FHOECO48 Controls for 18" and 24" deep enclosures When using a disconnect switch, order: flange-operated switch (fusible or non-fusible) When using a circuit breaker, order: shaft [DSFHS-12 for 12" deep or DSFHS-17 circuit breaker for 18" deep enclosures; in 24" deep enclosures Pressure wire connectors platform must be used with shaft] flange-mounted handle handle (DSFHN-HS12) n operating cable [12" deep or 18" deep enclosures accept 36" or 48" cables; 24" deep enclosures When using a circuit breaker, order: require a 48" cable] circuit breaker () n operating mechanism Square D shaft [FSH-12 for 12" deep or FHS-17 for When using a disconnect switch, order: 18" deep enclosures; in 24" deep enclosures disconnect switch with operating mechanism platform must be used with shaft] universal handle mechanism handle mechanism (FHN-HS12) long operating rod (if required) Cutler-Hammer/Westinghouse When using a circuit breaker, order: When using a File C361 disconnect switch, order: circuit breaker disconnect switch with an operating mechanism n operating mechanism n operating handle (C361H1 or C361H3) universal handle mechanism long operating rod (if required) When using a File C371 circuit breaker operating mechanism with C-H/Westinghouse circuit breaker, order: When using a Class 9422 Type T disconnect switch circuit breaker with a cable mechanism, order: n operating mechanism disconnect switch with operating mechanism n operating handle (Class 9422, Type T) handle mechanism (Class 9422 Type -1) When using a Type SM handle mechanism, order: cable mechanism (Class 9422 CFT-O) 3-, 5-, or 10-foot circuit breaker Type SM handle mechanism When using a circuit breaker with a cable mechanism, order: circuit breaker (Square D) When using a Flex Shaft handle mechanism, order: handle mechanism (Class 9422 Type -1) circuit breaker cable mechanism (Class 9422 CFT-0) 3-, 5-, or 10-foot complete Flex Shaft handle mechanism 71
72 TYPE 12 SINGLE DOOR FREESTNDING ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT Flange-Mounted Disconnect Construction: 10 gauge steel. Seams continuously welded and ground smooth. ody stiffeners in larger enclosures for extra rigidity. Heavy duty lifting eyes. Heavy gauge continuous hinges. 3-point latching mechanisms operated by padlocking handle doors. Print pocket included. Oil-resistant gasket. Panel supports for panel. 3/8-16 threaded collar studs provided for mounting panel. Defeater on door requires a screwdriver to open. Finish: NSI 61 gray polyester powder outside and inside. Optional panels are painted white polyester powder. INDUSTRY STNDRDS UL 508 Type 12 NEM Type 12 CUL Type 12
73 SINGLE DOOR FREESTNDING ENCLOSURE FOR FLNGE-MOUNTED DISCONNECT C X 4.00 Flange-Mounted Disconnect PDLOCKLE HNDLE CONTINUOUS HINGE / PNEL SUPPORT X SECTION X-X PNEL 4.06 W D TOP OF DISCONNECT E THIS SPCE IS OCCUPIED Y DISCONNECT SWITCH ND FUSE CLIP (IF USED) OR CIRCUIT REKER F
74 TYPE 12 SINGLE DOOR FREESTNDING ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT Flange-Mounted Disconnect ustin Type 12 single door freestanding enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. llen-radley flange-mounted disconnect switches and ulletin 1494D flange-mounted operators for circuit breakers. llen-radley ulletin 1494V variable depth flange-operated disconnect switches and circuit breaker mechanisms. Cutler-Hammer/Westinghouse Type C361 disconnect switches and operator mechanisms. Cutler-Hammer Type C371 circuit breaker operating mechanisms. lso Type SM safety handle mechanisms and Flex Shaft handle operators for circuit breakers. General Electric Type STD flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. lso Spectra Flex cable operators for circuit breakers. I-T-E Max-Flex flange-mounted variable depth operating handles for disconnect switches and circuit breakers. Square D disconnect switches and circuit breakers used with Class 9422 flange-mounted variabledepth operating mechanisms or cable mechanisms. (These enclosures will not receive Class 9422 bracket-mounted disconnect devices, Class 9422TG1 or TG2 devices.) Catalog Enclosure Size Panel Catalog Panel Size Number xxc Number Ht. X Wd FSN/DSC 72x27.38x DSCP 60x FSN/DSC 72x33.38x DSCP 60x FSN/DSC 72x39.38x DSCP 60x FSN/DSC 84x39.38x DSCP 72x FSN/DSC 90x39.38x DSCP 78x FSN/DSC 90x39.38x DSCP 78x FSN/DSC 84x39.38x DSCP 72x FSN/DSC 90x39.38x DSCP 78x33.75
75 SINGLE DOOR FREESTNDING ENCLOSURES FOR FLNGE-MOUNTED DISCONNECTS When ordering floor-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. llen-radley General Electric When using a ulletin 1494F flange-mounted When ordering a disconnect switch, order: disconnect switch, order: disconnect switch (Type QMR or QMW) disconnect switch fuse clip or no-fuse kit fuse block adapter (if required) flange handle (STD1 or STD2) Line and load connector (if required) variable depth operating mechanism n extended length drive rod (if required) When using a ulletin 1494D flange-mounted operator for a circuit breaker, order: When using a circuit breaker, order: circuit breaker (C-H/Westinghouse) circuit breaker flange-mounted operator mechanism flange handle (STD1 or STD2) slide mechanism variable depth operating mechanism n extended length drive rod (if required) When using a ulletin 1494V disconnect switch, order: disconnect switch When using a circuit breaker with a Spectra Flex cable n operating handle operator, order: connecting rod (long) circuit breaker trailer fuse block kit (if required) flange-mounted handle mechanism fuse clip kit (if required) breaker-mounted mechanism Line and load connectors (if required) n operating cable Flange-Mounted Disconnect When using a ulletin 1494V circuit breaker operating I-T-E Siemens mechanism, order: When using a disconnect switch, order: circuit breaker (C-H/Westinghouse) basic switch (right-hand) circuit breaker operating mechanism fuse or no-fuse kit n operating handle FHOHS flange-mounted handle connecting rod (long) Switch operator FHOECO36 cable for 12" deep or FHOECO48 Controls for 18" and 24" deep enclosures When using a disconnect switch, order: flange-operated switch (fusible or non-fusible) When using a circuit breaker, order: shaft [DSFHS-12 for 12" deep or DSFHS-17 circuit breaker for 18" deep enclosures; in 24" deep enclosures Pressure wire connectors platform must be used with shaft] flange-mounted handle handle (DSFHN-HS12) n operating cable [12" deep or 18" deep enclosures accept 36" or 48" cables; 24" deep enclosures When using a circuit breaker, order: require a 48" cable] circuit breaker () n operating mechanism Square D shaft [FSH-12 for 12" deep or FHS-17 for When using a disconnect switch, order: 18" deep enclosures; in 24" deep enclosures disconnect switch with operating mechanism platform must be used with shaft] universal handle mechanism handle mechanism (FHN-HS12) long operating rod (if required) Cutler-Hammer/Westinghouse When using a circuit breaker, order: When using a File C361 disconnect switch, order: - circuit breaker disconnect switch with an operating mechanism n operating mechanism n operating handle (C361H1 or C361H3) universal handle mechanism long operating rod (if required) When using a File C371 circuit breaker operating mechanism with C-H/Westinghouse circuit breaker, order: When using a Class 9422 Type T disconnect switch circuit breaker with a cable mechanism, order: n operating mechanism disconnect switch with operating mechanism - n operating handle (Class 9422, Type T) handle mechanism (Class 9422 Type -1) When using a Type SM handle mechanism, order: cable mechanism (Class 9422 CFT-O) 3-, 5-, or 10-foot circuit breaker Type SM handle mechanism When using a circuit breaker with a cable mechanism, order: circuit breaker (Square D) When using a Flex Shaft handle mechanism, order: handle mechanism (Class 9422 Type -1) circuit breaker cable mechanism (Class 9422 CFT-0) 3-, 5-, or 10-foot complete Flex Shaft handle mechanism 75
76 TYPE 12 FREESTNDING DOULE DOOR ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT Flange-Mounted Disconnect Construction: 10 gauge steel. Seams continuously welded and ground smooth. ody stiffeners in larger enclosures for extra rigidity. Heavy duty lifting eyes. Removable centerpost for easy installation of panel. Heavy gauge continuous hinges. 3-point latching mechanisms operated by padlocking handle on all doors. Print pocket included. Oil-resistant gasket. Panel supports for panel. 3/8-16 threaded collar studs provided for mounting panel. Defeater on master door requires a screwdriver to open. Mechanical interlock operated by master door prevents slave door from being opened first. Finish: NSI 61 gray polyester powder outside and inside. Optional panels are painted white polyester powder. INDUSTRY STNDRDS UL 508 Type 12 NEM Type 12 CUL Type 12
77 FREESTNDING DOULE DOOR ENCLOSURE FOR FLNGE-MOUNTED DISCONNECT C X Flange-Mounted Disconnect PDLOCKLE HNDLE / ODY STIFFENER PNEL SUPPORT CONTINUOUS HINGE X SECTION X-X PNEL 4.06 W D TOP OF DISCONNECT E THIS SPCE IS OCCUPIED Y DISCONNECT SWITCH ND FUSE CLIP (IF USED) OR CIRCUIT REKER F
78 TYPE 12 FREESTNDING DOULE DOOR ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT ustin Type 12 double door freestanding enclosures for flange-mounted disconnects are designed to house the following safety disconnect equipment: Flange-Mounted Disconnect Controls flange-mounted variable depth operating mechanisms for disconnect switches and circuit breakers. llen-radley ulletin 1494F flange-mounted disconnect switches and ulletin 1494D flangemounted operators for circuit breakers. llen-radley ulletin 1494V variable depth flange-operated disconnect switches and circuit breaker mechanisms. Cutler-Hammer/Westinghouse Type C361 disconnect switches and operator mechanisms. Cutler-Hammer Type C371 circuit breaker operating mechanisms. lso Type SM safety handle mechanisms and Flex Shaft handle operators for circuit breakers. General Electric Type STD flange handles and variable depth operating mechanisms for disconnect switches and circuit breakers. lso Spectra Flex cable operators for circuit breakers. I-T-E Max-Flex flange-mounted variable depth operating handles for disconnect switches and circuit breakers. Square D disconnect switches and circuit breakers used with Class 9422 flange-mounted variabledepth operating mechanisms or cable mechanisms. (These enclosures will not receive Class 9422 bracket-mounted disconnect devices, Class 9422TG1 or TG2 devices.) Catalog Enclosure Size Panel Catalog Panel Size Number xxc Number Ht. X Wd FSND/DSC 72x53.62x DSCP FSND/DSC 72x65.62x DSCP FSND/DSC 72x77.62x DSCP FSND/DSC 84x77.62x DSCP FSND/DSC 90x77.62x DSCP FSND/DSC 90x77.62x DSCP FSND/DSC 72x77.62x DSCP FSND/DSC 84x77.62x DSCP FSND/DSC 90x77.62x DSCP 60x46 60x58 60x70 72x70 78x70 78x70 60x70 72x70 78x70
79 FREESTNDING DOULE DOOR ENCLOSURE FOR FLNGE-MOUNTED DISCONNECT When ordering floor-mounted disconnects from the various manufacturers, be sure to order the necessary items. Each company has a different system, so make sure to order the following items from the disconnect manufacturer. llen-radley General Electric When using a ulletin 1494F flange-mounted When ordering a disconnect switch, order: disconnect switch, order: disconnect switch (Type QMR or QMW) disconnect switch fuse clip or no-fuse kit fuse block adapter (if required) flange handle (STD1 or STD2) Line and load connector (if required) variable depth operating mechanism n extended length drive rod (if required) When using a ulletin 1494D flange-mounted operator for a circuit breaker, order: When using a circuit breaker, order: circuit breaker (C-H/Westinghouse) circuit breaker flange-mounted operator mechanism flange handle (STD1 or STD2) slide mechanism variable depth operating mechanism n extended length drive rod (if required) When using a ulletin 1494V disconnect switch, order: disconnect switch When using a circuit breaker with a Spectra Flex cable n operating handle operator, order: connecting rod (long) circuit breaker trailer fuse block kit (if required) flange-mounted handle mechanism fuse clip kit (if required) breaker-mounted mechanism Line and load connectors (if required) n operating cable Flange-Mounted Disconnect When using a ulletin 1494V circuit breaker operating I-T-E Siemens mechanism, order: When using a disconnect switch, order: circuit breaker (C-H/Westinghouse) basic switch (right-hand) circuit breaker operating mechanism fuse or no-fuse kit n operating handle FHOHS flange-mounted handle connecting rod (long) Switch operator FHOECO36 cable for 12" deep or FHOECO48 Controls for 18" and 24" deep enclosures When using a disconnect switch, order: flange-operated switch (fusible or non-fusible) When using a circuit breaker, order: shaft [DSFHS-12 for 12" deep or DSFHS-17 circuit breaker for 18" deep enclosures; in 24" deep enclosures Pressure wire connectors platform must be used with shaft] flange-mounted handle handle (DSFHN-HS12) n operating cable [12" deep or 18" deep enclosures accept 36" or 48" cables; 24" deep enclosures When using a circuit breaker, order: require a 48" cable] circuit breaker () n operating mechanism Square D shaft [FSH-12 for 12" deep or FHS-17 for When using a disconnect switch, order: 18" deep enclosures; in 24" deep enclosures disconnect switch with operating mechanism platform must be used with shaft] universal handle mechanism handle mechanism (FHN-HS12) long operating rod (if required) Cutler-Hammer/Westinghouse When using a circuit breaker, order: When using a File C361 disconnect switch, order: - circuit breaker disconnect switch with an operating mechanism n operating mechanism n operating handle (C361H1 or C361H3) universal handle mechanism long operating rod (if required) When using a File C371 circuit breaker operating mechanism with C-H/Westinghouse circuit breaker, order: When using a Class 9422 Type T disconnect switch circuit breaker with a cable mechanism, order: n operating mechanism disconnect switch with operating mechanism - n operating handle (Class 9422, Type T) handle mechanism (Class 9422 Type -1) When using a Type SM handle mechanism, order: cable mechanism (Class 9422 CFT-O) 3-, 5-, or 10-foot circuit breaker Type SM handle mechanism When using a circuit breaker with a cable mechanism, order: circuit breaker (Square D) When using a Flex Shaft handle mechanism, order: handle mechanism (Class 9422 Type -1) circuit breaker cable mechanism (Class 9422 CFT-0) 3-, 5-, or 10-foot complete Flex Shaft handle mechanism 79
80 TYPE 12 FLOOR MOUNT & FREESTNDING ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT Flange-Mounted Disconnect llen-radley 1494F Disconnect Switches Wire end Space bove Disconnect Floor Mount Freestanding llen-radley 1494F Disconnect Switches Type 12 Type 12 When When When When When Type mp Fuse Fuse Space Occupied = 60 = 72 = 72 = 84 = 90 Number Rating Clip Class E F* W W W W W N30 30 NO FUSE N NF V H,K,R NF V H,K,R NF V H,K,R NF V H,K,R NF V J NF V J N60 60 NO FUSE N NF V H,K,R NF V H,K,R NF V H,K,R NF V H,K,R NF V H,K,R NF V J NF V J N NO FUSE N N NF V H,K,R N NF V H,K,R N NF V H,K,R N NF V H,K,R N NF V J N NF V J N N NO FUSE N N NF V H,K,R N NF V H,K,R N NF V H,K,R N NF V H,K,R N NF V J N NF V J N *The "F" dimensions do not include space for auxiliary switches. See llen-radley instructions for additional space required.
81 DISCONNECT WIRING SPCE INFORMTION Wire end Space bove Disconnect llen-radley ulletin 1494D Operators for Circuit reakers Floor Mount Freestanding Type 12 Type 12 When When When When When Type Frame Circuit reaker Type Space Occupied = 60 = 72 = 72 = 84 = 90 Number Rating Frame Size E F* W W W W W N4/N Westinghouse EHD, FD, FD, FDC, HFD, HMCP N5/N General Electric TFC, TFK, THFK N5/N Westinghouse JD, JD, JDC, HJD, HMCP N5/N Westinghouse N KD, KD, KDC, HKD, HMCP *The "F" dimensions do not include space for auxiliary switches. See llen-radley for additonal space required. Flange-Mounted Disconnect For Floor Mount Disconnects: "D" = 5.88 when "" = 60 "D" = when "" = 72 (except for 200 switches) "D" = when "" = 72 (for 200 switches) For Freestanding Disconnects: "D" = 9.88 when "" = 72 (except for 200 switches) "D" = 8.56 when "" = 72 (for 200 switches) "D" = when "" = 84 (except for 200 switches) "D" = when "" = 84 (for 200 switches) "D" = when "" = 90 (except for 200 switches) "D" = when "" = 90 (for 200 switches) llen-radley 1494V Disconnect Switches Wire end Space bove Disconnect llen-radley 1494V Disconnect Switches Floor Mount Freestanding Type 12 Type 12 When When When When When Type mp Fuse Fuse Space Occupied = 60 = 72 = 72 = 84 = 90 Number Rating Clip Class E F* W W W W W DS30 30 NO FUSE N DS V H,K,R DS V H,K,R DS V J DS V H,K DS V H,K DS V J DS60 60 NO FUSE N DS V H,K,R DS V H,K,R DS V J DS V H,K,R DS V H,K DS V H,K DS V J DS100** 100 NO FUSE N DS100** V H,K,R DS100** V H,K,R DS100** V J DS100** V H,K,R DS100** V J DS200** 200 NO FUSE N DS200** V H,K,R DS200** V H,K,R DS200** V J DS200** V H,K,R DS200** V J *The "F" dimensions do not include space for auxiliary switches. See llen-radley instructions for additional space required. **Series 81
82 TYPE 12 FLOOR MOUNT & FREESTNDING ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT Flange-Mounted Disconnect Wire end Space bove Disconnect llen-radley ulletin 1494V Operators for Circuit reakers Floor Mount Freestanding Type 12 Type 12 When When When When When Type Frame Circuit reaker Type Space Occupied = 60 = 72 = 72 = 84 = 90 Number Rating Frame Size E F* W W W W W M Westinghouse EHD, FD, FD, FDC, HFD, HMCP M Westinghouse JD, JD, JDC, HJD, HMCP M Westinghouse N KD, KD, KDC. HKD, HMCP *The "F" dimensions do not include space for auxiliary switches. See llen-radley instructions for additional space required. For Floor Mount Disconnects: For Floor Mount Disconnects: "D" = 7.88 when "" = 60 "D" = when "" = 72 For Freestanding Disconnects: For Freestanding Disconnects: "D" = when "" = 72 "D" = when "" = 84 "D" = when "" = 90 Wire end Space bove Disconnect Controls Disconnect Switches Double Door Freestanding with Flange-Mounted Operators Type 12 Type 12 When When When When When Switch mp Fuse Fuse Space Occupied = 60 = 72 = 72 = 84 = 90 Number Rating Clip Class E F W W W W W OETL-NF30-F 40 NO FUSE N OETL-NF60-F 80 NO FUSE N OETL-NF100-F 100 NO FUSE N OETL-NF175-F 175 NO FUSE N OETL-NF200-F 200 NO FUSE N OES-F30J6-F V J OES-F60J6-F V J OES-F100J6-F V J
83 DISCONNECT WIRING SPCE INFORMTION Wire end Space bove Disconnect Controls Circuit reakers Floor Mount Freestanding with Flange-Mounted Operators Type 12 Type 12 When When When When When Mechanism mp Frame Space Occupied = 60 = 72 = 72 = 84 = 90 Rating Type E F W W W W W FHD-M 150 D FHF-M E/Q FHF-M 225 F FHJ-M 400 J FHM-M 600 L N FHM-M 800 M N FHN-M 1200 N N N N Flange-Mounted Disconnect For Floor Mount For Disconnects: Floor Mount Disconnects: "D" = 7.88 when "" = 60 "D" = when "" = 72 For Freestanding For Disconnects: Freestanding Disconnects: "D" = when "" = 72 "D" = when "" = 84 "D" = when "" = 90 Wire end Space bove Disconnect Double Door Freestanding Cutler-Hammer C361 Disconnect Switches Type 12 Type 12 When When When When When Switch mp Fuse Fuse Space Occupied = 60 = 72 = 72 = 84 = 90 Number Rating Clip Class E F W W W W W C361NC 30 NO FUSE N C361SC V H,K,R C361SC V H,K,R C361SC V H,J,K,R C361ND 60 NO FUSE N C361SD V H,K,R C361SD V J C361SD V H,K,R C361SD V J C361NE 100 NO FUSE N C361SE V H,K,R C361SE V H,K,R C361SE V J C361NF 200 NO FUSE N C361SF V H,K,R C361SF V H,J,K,R
84 TYPE 12 FLOOR MOUNT & FREESTNDING ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT Wire end Space bove Disconnect Flange-Mounted Disconnect Cutler-Hammer C371 Circuit reaker Operators Floor Mount Freestanding for C-H / Westinghouse Circuit reakers Type 12 Type 12 When When When When When Mechanism Max mp Frame Space Occupied = 60 = 72 = 72 = 84 = 90 Rating Type E F W W W W W C371E 225 F Frame: EHD, FD, FD, HFD, FDC C371E 150 F Frame: HMCP C371F 250 J Frame: JD, JD, HJD, JDC * C371F 250 J Frame: HCMP * C371F 400 K Frame: DK, KD, KD, HKD * C371F 400 K Frame: HMCP * C371G 600 L Frame: LD, HLD, LDC N 10.88** C371G 600 L Frame: HMCP N 10.88** C371K 800 M Frame: MD, MDS N N N C371K 1200 N Frame: ND, HND, NDC N N N 11.31*** *vailable wire bend space "W" does not allow cable sizes larger than 4/0 WG in a 60" tall enclosure. **vailable wire bend space "W" does not allow cable sizes larger than 300 MCM. ***vailable wire bend space "W" does not allow cable sizes larger than 350 MCM in a 90" tall enclosure when using 4 cable per terminal. See National Electrical Code 1999 table 373-6(b) for more information. vailable wire bend space "W" is insufficient for use with Westinghouse breakers equipped with T1201N1 terminals. For Floor Mount Disconnects: For Floor Mount Disconnects: "D" = 7.88 when "" = 60 "D" = when "" = 72 For Freestanding Disconnects: For Freestanding Disconnects: "D" = when "" = 72 "D" = when "" = 84 "D" = when "" = 90 Cutler-Hammer Flex Shaft Operator Mechanisms for C-H/Westinghouse Circuit reakers Complete Operator mp Frame reaker reaker Mechanism Rating Type Height Width F1S F-Frame/EHD, FD, FD, HFD, FDC F1S F-Frame HMCP F2S J-Frame/JD, JD, HJD, JDC F2S J-Frame HMCP F3S K-Frame/DK, KD, KD, HKD F3S K-Frame HMCP F4S L-Frame/LD, HLD, LDC F4S L-Frame HMCP F7S M-Frame/MD, MDS F5S N-Frame/ND, HND, NDC F6S R-Frame/RD, CRD, RDC Catalog numbers for complete mechanisms include a flange-mounted handle, flexible shaft and circuit breaker mechanism. -The last digit of the catalog number denotes the length of shaft (F1S03 = 3 foot shaft). The F, J, K frame Flex Shafts are available in 3-foot to 10-foot lengths. The L, N, R frame Flex Shafts are available in 4-foot to 6-foot lengths. Space Occupied by Disconnect *The Flex Shaft system allows the circuit breaker to be positioned independent from the flange-mounted handle mechanism. *Refer to National Electrical Code 1999, article (b) for wiring space "W" required for line side conductors. *Choose the length of shaft based on placement of the circuit breaker in the enclosure ensuring a 4" minimum bending radius for the Flex Shaft. *Space occupied by circuit breaker is determined by overall height "X", width "Y", wire bend space "W" and location "F" as selected from right to left.
85 DISCONNECT WIRING SPCE INFORMTION Wire end Space bove Disconnect Cutler-Hammer Type SM Safety Handle Floor Mount Freestanding Mechanisms for C-H/Westinghouse Circuit reakers Type 12 Type 12 When When When When When Handle Use with Space Occupied = 60 = 72 = 72 = 84 = 90 Mechanism Circuit reaker E F W W W W W SM101PR F Tri-Pac SM150R F Frame EHD, FD, FD, HFD, FDC SM250JR J Frame JD, JD, HJD, JDC N SM400KR K Frame DK, KD, KD, HKD N SM400PR L Tri-Pac N SM600R L Frame LD, HLD, LDC N N N SM800R M Frame MD, MDS, HMD N N N SM8000PR N Tri-Pac N N N Flange-Mounted Disconnect Floor Mount Disconnects: For Floor Mount Disconnects: "D" = 7.31 when "" = 60 for up to type SM200 "D" = when "" = 72 for up to type SM200 "D" = 6.88 when "" = 60 for type SM200 and larger "D" = when "" = 72 for type SM200 and larger reestanding Disconnects: For Freestanding Disconnects: "D" = when "" = 72 for up to type SM200 "D" = when "" = 84 for up to type SM200 "D" = when "" = 90 for up to type SM200 "D" = when "" = 72 for type SM200 and larger "D" = when "" = 84 for type SM200 and larger "D" = when "" = 90 for type SM200 and larger Wire end Space bove Disconnect General Electric Type STD Double Door Freestanding Disconnect Switch Operators Type 12 Type 12 When When When When When Mechanism mp Fuse Fuse Space Occupied = 60 = 72 = 72 = 84 = 90 Rating Clip Class E F W W W W W TD0M1 30 NO FUSE N TD0M V H,R TD0M V H,R TD0M V H,R TD0M V H,R TD0M1 60 NO FUSE N TD0M V H,R TD0M V H,R TD0M V H,R TD0M V H,R TD0M1 100 NO FUSE N TD0M V H,R TD0M V H,R TD0M V H,R TD0M V H,R TD0M2 200 NO FUSE N TD0M V H,R TD0M V H,R
86 TYPE 12 FLOOR MOUNT & FREESTNDING ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT Wire end Space bove Disconnect General Electric Type STD Floor Mount Freestanding Enc Operators for Circuit reakers Type 12 Type 12 When When When When Mechanism mp Frame Space Occupied = 60 = 72 = 72 = 84 Rating Type E F W W W W Flange-Mounted Disconnect SD0M1 150 TE, TED, THED SD0M1 150 TEC TD0M1 150 T TD0M1 150 TEC, TECL TD0M1C 150 TEL TD0M1D 150 THLC TD0M3 225 TFJ TD0M3 225 TFK, THFK, TFL TD0M4 400 TJJ, TJK4, THJK4, TJL4V N TD0M4 600 TJK6, THJK6, TJ4V, TJL4V N TD0M5 400 T4, TJH6S N TD0M6 225 TL2, THLC N N TD0M6 400 TL4, THLC N 9.47 N TD0M TKN, THKM, TK4V N N N N TD0M TK4V, THK4V N N N N TD0M7 600 T N N N TD0M7 800 T N N N TD0M TKL12S N N N N SD0M1 150 SPECTR SE SD0M3 250 SPECTR SF SD0M4 600 SPECTR SG N 8.68 N For Floor Mount Disconnects: For Floor Mount Disconnects: "D" = 7.88 when "" = 60 "D" = when "" = 72 For Freestanding Disconnects: For Freestanding Disconnects: "D" = when "" = 72 "D" = when "" = 84 "D" = when "" = 90 General Electric Circuit reakers with Spectra Flex Cable Operators Frame Max mp Circuit reaker Circuit reaker Size Rating Height Width "X" "Y" E SE SF SG SK See enclosure size tables for enclosures that will accept these devices Frame Size reaker Mechanism Flange Mounting Handle Operating Cable* E150 SC0M1 SCH1 SC3L SE150/SF250 SCOM1EF SCH1 SC3L SG600 SCOM1G SCH1 SC3L SK1200 SCOM1K SCH3K SC3H *Operating cables are available in 3-foot to 10-foot lengths. (The number 3 in the catalog number denotes 3-foot cable). Space Occupied by Circuit reaker *The General Electric Spectra-Flex cable operators allow a Circuit reaker to be positioned independent from the flange-mounted handle mechanism. *Refer to National Electrical Code article (b) for wiring space "W" for line side conductors. *Choose the operating cable length based on placement of circuit breaker in the enclosure ensuing a 3" minimum bending radius for the cable. *Space occupied by circuit breaker is determined by overall circuit breaker size ("X" height and "Y" width) plus "W" wire bend space and location "F" (from right to left) as selected. For Floor Mount Disconnects: "D" = 7.88 when "" = 60 "D" = when "" = 72 For Freestanding Disconnects: "D" = when "" = 72 "D" = when "" = 84 "D" = when "" = 90
87 DISCONNECT WIRING SPCE INFORMTION I-T-E Disconnect Switches for Max-Flex Operators Switch mp Fuse Fuse Disconnect Disconnect Rating Clip Class Height Width "X" "Y" MCS603R 30 NO FUSE N MCS603R V H,K,R MCS603R V H,K,R MCS603R V J MCS606R 60 NO FUSE N MCS606R V H,K,R MCS606R V H,K,R MCS606R V J MCS610R 100 NO FUSE N MCS610R V H,K,R MCS610R V H,K,R MCS610R V J Flange-Mounted Disconnect MCS620R 200 NO FUSE N MCS620R V H,K,R MCS620R V H,K,R MCS620R V J See enclosure size table for enclosures that accept these devices Floor Mount enclosures that are 24" deep require a 48" Max-Flex cable (minimum) I-T-E Circuit reakers with Max-Flex Operators Complete (1) (2) Circuit Maximum Circuit Circuit Circuit Operator reaker mp reaker reaker reaker Mechanism Frame Rating Height Width Type "X" "Y" FH0E036 ED ED2, ED4, ED6, HED4, HED6 FH0E36 CED CED6 FH0F036 FD FXD6-, FD6-, HFD6. FXD6-ETJ, HHFD6, HHFXD6 FH0J036 CFD CFD6, CFD6-ETI FH0J036 JD JXD2, JXD6, JD6, HJD6, HHJD6, HHJXD6, JXD6-ETI FH0J036 CJD CJD6, CJD6-ETI FH0J036 LD LXD6, LD6, HLD6, HHLD6, HHLDX6, LXD6-ETI FH0J036 CLD CLD6, CLD6-ETI FH0LM036 LMD LMD6, LMXD6, HLMD6, HLMXD6, LMXD6-ETI Mechanisms and Circuit reakers listed above will fit any enclosure (1)- The last 3 digits of operator mechanism number indicate cable length in inches. 48" cables are available for ED, FD, JD/LD operators, and 60" cables for MD/ND, PD/RD operators. (2)- For Type 4 applications order handle, cable and circuit breaker operator separately or Floor Mount Disconnects: "D" = 7.88 when "" = 60 For Floor Mount Disconnects: "D" = when "" = 72 r Freestanding Disconnects: "D" = when "" = 72 For Freestanding Disconnects: "D" = when "" = 84 "D" = when "" = 90 Space Occupied by Disconnect. *The I-T-E Max-Flex cable system allows the disconnect to be positioned independent from the flange-mounted handle operator. *Refer to National Electrical Code 1999 article (b) for wiring space "W" required for line side conductors. *Refer to Siemens I-T-E installation instructions for limits on disconnect location when using a 36" or 48" Max-Flex cables. *Space occupied by disconnect is determined by overall disconnect height "X", width "Y", wire bend space "W", and location "F" from right to left as selected. 87
88 TYPE 12 FLOOR MOUNT & FREESTNDING ENCLOSURE FOR FLNGE- MOUNTED DISCONNECT Square D Class 9422 Variable Depth Disconnects Switches Wire end Space bove Disconnect Flange-Mounted Disconnect Double Door Freestanding Type 12 Type 12 Square D Class 9422 Variable Depth Disconnects Switches When When When When When Type mp Fuse Fuse Space Occupied = 60 = 72 = 72 = 84 = 90 Number Rating Clip Class E F W W W W W TCN NO FUSE N TCF V H,K,R TCF V H,K,R TCF V H,K,R TCF V J TDN NO FUSE N TDF V H,K,R TDF V H,K,R TDF V H,K,R TDF V J TEN NO FUSE N TEF V H,K,R TEF V H,K,R TEF V J TEF V J N N TC-1 30 NO FUSE N TC V H,K,R TC V H,K,R TC V H,K,R TC V J TD-1 60 NO FUSE N TD V H,K,R TD V H,K,R TD V H,K,R TD V J TE NO FUSE N TE V H,K,R TE V H,K,R TE V J TE V J TF NO FUSE N TF V H,K,R TF V H,K,R TF V J TF V J Wire end Space bove Disconnect Square D Class 9422 Variable Double Door Freestanding Depth Operators-Circuit reakers Type 12 Type 12 When When When When When Type mp Fuse Space Occupied = 60 = 72 = 72 = 84 = 90 Number Rating Clip E F W W W W W RG-1 75 GJL RG GJL RN FL, FHL RP KL, KHL RR LL, LHL, Q4L N 8.75 N RT MEL, MXL N N N RT ML, MHL N N N For Floor For Mount Floor Disconnects: Mount Disconnects: "D" = 7.88 when "" = 60 "D" = when "" = 72 For Freestanding For Freestanding Disconnects: Disconnects: "D" = when "" = 72 "D" = when "" = 84 "D" = when "" = 90
89 DISCONNECT WIRING SPCE INFORMTION Square D Class 9422 Disconnect Switches used with Cable Mechanism 9422-CFT30* and Handle Mechanism Switch mp Fuse Fuse Disconnect Disconnect Rating Clip Class Height Width "X" "Y" TCN NO FUSE N TCF V H,K,R TCF V H,K,R TCF V H,K,R TCF V J TDN NO FUSE N TDF V H,K,R TDF V H,K,R TDF V H,K,R TDF V J Flange-Mounted Disconnect TEN NO FUSE N TEF V H,K,R TEF V H,K,R TEF V J See enclosure size table for enclosures that accept these devices. *Use switches listed above with appropriate cable mechanism and handle mechanism. Cable operators are available in 3-foot, 5-foot and 10-foot lengths. Numbers shown (30) are for 3-foot cables Square D Class 9422 Cable Mechanisms for Circuit reakers Cable Type* mp Frame Circuit reaker Switch Rating Type Height "X" 9422 CGJ30 75 GJL CEJ GJL CF FL, FHL CK KL, KHL CL LL, LHL, Q4L See enclosure size table for enclosures that accept these devices. Use cable mechanism with appropriate circuit breaker and handle mechanism. *Cable operators are available in 3-foot, 5-foot and 10-foot lengths. Numbers shown (30) are for 3-foot cables. Space Occupied by Disconnect Switch or Circuit reaker -Space D cable mechanisms allow disconnect device to be positioned independent from the flange-mounted handle mechanism. -Refer to National Electrical Code 1999 article (b) for wiring space "W" required for line side conductors. -Choose cable mechanism length based on placement of disconnect in enclosure. See Square D Instruction ulletin for minimum bend raduis for cable. -Space occupied by disconnect is determined by overall disconnect ("X" height and "Y" width) plus "W" wire bend space and location "F" (from right to left) as selected. 89
90 JIC CONTINUOUS HINGE OXES ustin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from 14 gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. Cover held in place by continuous hinge on one side and stainless steel external screw clamps on opposite side. External mounting feet. that are 6x4x3 and over have stand-offs provided for mounting optional panel or terminal kit. Finish: Y Y ustin JIC Continuous Hinge boxes are provided standard with an NSI 61 gray polyester powder coating. Optional panel are painted white. 1 CLMP USED WHEN "" IS LESS THN 8".31 DI. Options: Special materials. Special finishes. PNEL (Optional) C+.44 C.50 Custom box size or construction. Hasp for padlocking SECTION Y-Y FRONT VIEW WITH NO COVER ND CLMPS REMOVED INDUSTRY STNDRDS UL 50 Type 12 & 13 UL 508 Type 12 & 13 NEM Type 12 & 13 CUL Type 12 & 13
91 JIC CONTINUOUS HINGE OXES Type 4, 12 & 13 Oiltight 91
92 JIC LIFT-OFF HINGE OXES ustin JIC Lift-Off Hinge (JL) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from 14 gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. Cover held in place by stainless steel external screw clamps. Chain holds cover to box when cover is removed. that are 6x4x3 and over have stand-offs provided for mounting optional panel. External mounting feet. Y.31 DI. Finish: PNEL (Optional) ustin JIC Lift-Off Hinge boxes are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white. Y Options: COVER TTCHED TO OX Y SMLL CHIN (NOT SHOWN). WHEN "" = 8 OR MORE, 2 CLMPS RE USED T THIS END FRONT VIEW WITH NO COVER ND CLMPS REMOVED Special materials. Special finishes. C+.44 C.50 Custom box size or construction. SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 & 13 UL 508 Type 12 & 13 NEM Type 12 & 13 CUL Type 12 & 13
93 JIC LIFT-OFF HINGE OXES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number -443JL 4x4x3 2 N -643JL 6x4x3 3-64JP JL 8x6x3 1/2 5-86JP -444JL 4x4x4 5 N -644JL 6x4x4 2-64JP -664JL 6x6x4 3-66JP -1084JL 10x8x JP JL 12x10x JP JL 14x12x JP JL 16x14x JP Type 4, 12 & 13 Oiltight 93
94 JIC SCREW COVER OXES ustin JIC Screw Cover (JS) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They are designed for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from 14 gauge steel. Neoprene gasket attached to cover with oil resistant adhesive. Cover attached with captivated screws threaded into sealed wells. Continuously welded seams ground smooth. External mounting feet. that are 6x4x3 and over are provided with stand-offs for mounting optional panel. Finish: Y Y PNEL (Optional).31 DI ustin JIC Screw Cover boxes are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white FRONT VIEW WITH COVER REMOVED Options: Special materials. Special finishes. C+.44 C Custom box size or construction..50 SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 4, 12 & 13 UL 508 Type 4, 12 & 13 NEM Type 4, 12 & 13 CUL Type 4, 12 & 13
95 JIC SCREW COVER OXES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number -443JS 4x4x3 2 N -643JS 6x4x3 3-64JP JS 8x6x3 1/2 5-86JP 444JS 4x4x4 2 N -644JS 6x4x4 3-64JP -664JS 6x6x4 4-66JP -884JS 8x8x4 7-88JP -1084JS 10x8x JP JS 10x10x JP JS 12x10x JP -866JS 8x6x6 7-86JP -1086JS 10x8x JP JS 10x10x JP JS 12x12x JP JS 14x12x JP JS 16x14x JP Type 4, 12 & 13 Oiltight 95
96 JIC NEM 4 CONTINUOUS HINGE OXES ustin JIC Continuous Hinge NEM 4 (JFH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They are designed for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from 14 gauge steel. Neoprene gasket attached to cover with oil resistant adhesive. Stainless steel external screw clamps on three sides. Stainless steel continuous hinge. Continuously welded seams ground smooth. External mounting feet. that are 6x4x3 and over are provided with stand-offs for mounting optional panel..31 DI. Finish: Y Y PNEL (Optional) ustin JIC Continuous Hinge NEM 4 boxes are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white FRONT VIEW WITH NO COVER ND CLMPS REMOVED C+.44 C Options:.50 Special materials SECTION Y-Y Special finishes. Custom box size or construction. 6x4 6x6 4x4 8x6 8x8 LC 10x8 10x10 LC 12x10 12x12 14x12 16x14 Hasp for padlocking. C L LC 2.50 INDUSTRY STNDRDS UL 50 Type 4, 12 & 13 UL 508 Type 4, 12 & 13 NEM Type 4, 12 & 13 CUL Type 4, 12 & 13
97 JIC NEM 4 CONTINUOUS HINGE OXES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number -443JFH 4x4x3 2 N -643JFH 6x4x3 3-64JP JFH 8x6x3 1/2 6-86JP -664JFH 6x6x4 4-66JP -1084JFH 10x8x JP JFH 12x10x JP JFH 10x10x JP JFH 12x12x JP JFH 14x12x JP JFH 16x14x JP Type 4, 12 & 13 Oiltight 97
98 JIC NEM 4 CLMP COVER OXES ustin JIC Clamp Cover NEM 4 (JFC) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They are designed for indoor and outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from 14 gauge steel. Continuously welded and ground smooth. Cover held in place by stainless steel external screw clamps all four sides. Neoprene gasket attached to cover with oil resistant adhesive. External mounting feet. that are 6x4x3 and over have stand-offs provided for mounting optional panel..31 DI. Finish: Y Y PNEL (Optional) ustin JIC Clamp Cover NEM 4 boxes are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white FRONT VIEW WITH NO COVER ND CLMPS REMOVED C+.44 C.50 Options: Special materials SECTION Y-Y Special finishes. Custom box size or construction. 6x4 6x6 4x4 8x6 8x8 LC 10x8 10x10 LC 12x10 12x12 14x12 16x14 C L LC 2.50 INDUSTRY STNDRDS UL 50 Type 4, 12 & 13 UL 508 Type 4, 12 & 13 NEM Type 4, 12 & 13 CUL Type 4, 12 & 13
99 JIC NEM 4 CLMP COVER OXES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number -443JFC 4x4x3 2 N -643JFC 6x4x3 3-64JP JFC 8x6x3 1/2 6-86JP -664JFC 6x6x4 4-66JP -1084JFC 10x8x JP JFC 12x10x JP JFC 14x12x JP JFC 16x14x JP Type 4, 12 & 13 Oiltight 99
100 JIC NEM 4X CONTINUOUS HINGE OXES ustin JIC Continuous Hinge NEM 4X (JHFX) boxes are Underwriters Laboratories Listed and are designed for housing electrical components in highly corrosive environments. They are designed for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from 14 gauge Type 304 stainless steel. Continuously welded seams ground smooth. Stainless steel external screw clamps. Stainless steel continuous hinge. Neoprene gasket attached to cover with oil resistant adhesive. External mounting feet. that are 6x4x3 and over have stainless steel stand-offs provided for mounting optional panel..31 DI. Finish: Y Y PNEL (Optional) ustin JIC Continuous Hinge NEM 4X boxes are provided standard in Type 304 stainless steel. Optional panels are painted white or stainless steel panels are unpainted FRONT VIEW WITH NO COVER ND CLMPS REMOVED C+.44 C Options: Type 316 Stainless Steel. SECTION Y-Y Custom box size or construction. 6x4 6x6 4x4 8x6 8x8 LC 10x8 10x10 LC 12x10 12x12 14x12 16x14 Hasp for padlocking. C L LC 2.50 INDUSTRY STNDRDS UL 50 Types 4, 4X, 12 & 13 UL 508 Types 4, 4X, 12 & 13 NEM Types 4, 4X, 12 & 13 CUL Types 4, 4X, 12 & 13
101 JIC NEM 4X CONTINUOUS HINGE OXES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number JHFX 8x6x3 1/2 6-86JP -664JHFX 6x6x4 5-66JP -884JHFX 8x8x4 7-88JP -1084JHFX 10x8x JP JHFX 12x10x JP JHFX 14x12x JP JHFX 16x14x JP Type 4, 12 & 13 Oiltight 101
102 JIC NEM 4X CLMP COVER OXES ustin JIC Clamp Cover NEM 4X (JFCX) boxes are Underwriters Laboratories Listed and are designed for housing electrical components in highly corrosive environments. They are designed for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose directed water and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from 14 gauge Type 304 stainless steel. Continuously welded seams and ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. Cover held in place by stainless steel external screw clamps. External mounting feet. that are 6x4x3 and over have stainless steel stand-offs provided for mounting optional panel..31 DI. Finish: Y Y PNEL (Optional) ustin JIC Clamp Cover NEM 4X boxes are provided standard in Type 304 stainless steel. Optional panels are painted white or stainless steel panels are unpainted FRONT VIEW WITH NO COVER ND CLMPS REMOVED C+.44 C.50 Options: Type 316 Stainless Steel. SECTION Y-Y Custom box size or construction. 6x4 6x6 4x4 8x6 8x8 LC 10x8 10x10 LC 12x10 12x12 14x12 16x14 C L LC 2.50 INDUSTRY STNDRDS UL 50 Types 4, 4X, 12 & 13 UL 508 Types 4, 4X, 12 & 13 NEM Types 4, 4X, 12 & 13 CUL Types 4, 4X, 12 & 13
103 JIC NEM 4X CLMP COVER OXES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number JFCX 8x6x3 1/2 6-86JP -664JFCX 6x6x4 5-66JP -884JFCX 8x8x4 7-88JP -1084JFCX 10x8x JP JFCX 12x10x JP JFCX 12x12x JP JFCX 14x12x JP JFCX 16x14x JP Type 4, 12 & 13 Oiltight 103
104 JIC LUMINUM CONTINUOUS HINGE OXES ustin JIC Continuous Hinge aluminum (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: Fabricated in accordance with UL specifications from code gauge Type 5052 H-32 aluminum. Cover held in place by external screw clamps and aluminum continuous hinge. External mounting feet. that are 6x4x3 and over have aluminum stand-offs provided for mounting optional panel. Type 4, 12 & 13 Oiltight Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. Finish: Y Y PNEL (Optional) DI ustin JIC continuous hinge aluminum boxes are provided standard in Type 5052 H-32 aluminum. Optional aluminum panels are unpainted and optional steel panels are painted white CLMP USED WHEN "" IS LESS THN 8" FRONT VIEW WITH NO COVER ND CLMPS REMOVED Options: Custom box size or construction. Hasp for padlocking. C+.44 C SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 & 13 UL 508 Type 12 & 13 NEM Type 12 & 13 CUL Type 12 & 13
105 JIC LUMINUM CONTINUOUS HINGE OXES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number -643JH 6X4X3 3-64JP JH 8x6x3 1/2 2-86JP -664JH 6x6x4 2-66JP -1084JH 10x8x JP JH 12x10x JP JH 14x12x JP JH 16x14x JP Type 4, 12 & 13 Oiltight 105
106 JIC NEM 4X LUMINUM CLMP COVER OXES ustin JIC Clamp Cover NEM 4X aluminum (JC) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They are designed for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose directed water, and damage from external ice formation. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from code gauge Type 5052 H-32 aluminum. Cover is held in place by external screw clamps on all four sides. Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. External mounting feet. that are 6x4x3 and over have aluminum stand-offs provided for mounting optional panel..31 DI. Finish: Y Y PNEL (Optional) ustin JIC Clamp Cover NEM 4X aluminum boxes are provided standard in Type 5052 H-32 aluminum. Optional aluminum panels are unpainted and optional steel panels are painted white FRONT VIEW WITH NO COVER ND CLMPS REMOVED C+.44 C.50 Options: SECTION Y-Y Custom box size or construction x4 6x6 4x4 8x6 8x8 LC 10x8 10x10 LC 12x10 12x12 14x12 16x14 C L LC 2.50 INDUSTRY STNDRDS UL 50 Types 4, 4X, 12 & 13 UL 508 Types 4, 4X, 12 & 13 NEM Types 4, 4X, 12 & 13 CUL Types 4, 4X, 12 & 13
107 JIC NEM 4X LUMINUM CLMP COVER OXES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number JC 8x6x3 1/2 2-86JP -664JC 6x6x4 2-66JP -1084JC 10x8x JP JC 12x10x JP JC 14x12x JP JC 16x14x JP Type 4, 12 & 13 Oiltight 107
108 SMLL OILTIGHT ENCLOSURES ustin small oiltight (STE) enclosures are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: Type 4, 12 & 13 Oiltight Fabricated from 14 gauge steel. Door attached by continuous hinge and captivated screws threaded into sealed wells. Neoprene gasket attached to door with oil resistant adhesive. External mounting feet. Stand-offs provided for mounting optional panel. Continuously welded seams ground smooth. Finish:.31 DI. ustin small oiltight enclosures are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white. Y Y FRONT VIEW WITH NO COVER ND NO HINGE Options: Special materials. Special finishes. C+.44 C.50 Custom box size or construction. Hasp for padlocking. SECTION Y-Y INDUSTRY STNDRDS UL 50 Type 12 & 13 UL 508 Type 12 & 13 NEM Type 12 & 13 CUL Type 12 & 13
109 SMLL OILTIGHT ENCLOSURES Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number -664STE 6x6x4 4-66JP -864STE 8x6x4 5-86JP -884STE 8x8x4 6-88JP -1084STE 10x8x JP STE 10x10x JP STE 12x10x JP -866STE 8x6x6 7-86JP -886STE 8x8x6 8-88JP -1086STE 10x8x JP STE 10x10x JP STE 12x10x JP STE 12x12x JP STE 14x12x JP Type 4, 12 & 13 Oiltight 109
110 LRGE OILTIGHT ENCLOSURES ustin large oiltight (JXL) enclosures are Underwriters Laboratories Listed and are designed to house electrical controls, instruments, and terminals. They provide a degree of protection against dust, dirt, spraying of water, oil, and noncorrosive liquids. Construction: Type 4, 12 & 13 Oiltight Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Door attached by continuous hinge and captivated screws threaded into sealed wells. Neoprene gasket attached to door with oil resistant adhesive. Standard plastic self-adhesive print pocket. Standard collar studs provided for mounting optional panel. External mounting feet. Finish: Y OMIT CENTER SCREW IF "" IS LESS THN 31" Y ustin large oiltight enclosures are provided standard with an NSI 61 gray polyester powder coating. Optional panels are painted white..43 DI..63 PNEL (Optional) Options: Special materials. Special finishes. OMIT CENTER STUDS IF "" IS LESS THN 31" C+.50 C 1.00 Custom box size or construction. SECTION Y-Y FRONT VIEW WITH NO COVER ND NO HINGE INDUSTRY STNDRDS UL 50 Type 12 & 13 UL 508 Type 12 & 13 NEM Type 12 & 13 CUL Type 12 & 13
111 LRGE OILTIGHT ENCLOSURES Catalog Enclosure Weight Panel Catalog Catalog Enclosure Weight Panel Catalog Number Size (xxc) Number Number Size (xxc) Number JXL 20x16x TP JXL 30x24x TP JXL 20x20x TP JXL 36x24x TP JXL 24x20x TP JXL 36x30x TP JXL 24x24x TP JXL 42x30x TP JXL 30x20x TP JXL 42x36x TP JXL 30x24x TP JXL 36x24x TP JXL 24x24x TP JXL 36x24x TP JXL 20x16x TP JXL 48x36x TP JXL 20x20x TP JXL 24x20x TP JXL 24x24x TP JXL 30x24x TP JXL 30x20x TP JXL 36x30x TP Type 4, 12 & 13 Oiltight 111
112 USTIN STNDRD PUSHUTTON ENCLOSURES ustin standard pushbutton enclosures are Underwriters Laboratories Listed and are designed to house standard oiltight switches, pilot lights, and pushbutton switches. They provide a degree of protection against dust, dirt, oil, and water. Construction: Fabricated from 14 gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. External mounting feet. Standard 4-way 30mm pushbutton holes. Cover held in place by captivated screws threaded into sealed wells. Finish: Pushbutton & Consolets Y 2.25 Y ustin standard pushbutton enclosures are provided standard with an NSI 61 gray polyester powder coating FRONT VIEW WITH COVER REMOVED C+.44 C Options: C-1 C-2 SECTION Y-Y C-3 D-1 D-3 HOLE RRNGEMENT D-4 E-1 E-4 E-5 NOTE: G-1 HS 1/2" DDED ON ECH SIDE OF THE CENTER HOLE. H-1 HS 1" DDED ETWEEN THE TWO CENTER HOLES. F-1 G-1 H-1 J-1 K-1 Special materials. Special finishes. Custom box size or construction. 4-way 22mm pushbutton holes. INDUSTRY STNDRDS UL 50 Types 4, 12 & 13 NEM Types 4, 12 & 13 CUL Types 4, 12 & 13
113 USTIN STNDRD PUSHUTTON ENCLOSURES lank Cover Catalog Enclosure Holes Hole Weight Number Size (xxc) rrangement -1NP 3 1/2x3 1/2x NP 6 3/4x3 1/2x NP 6 3/4x6 3/4x C1NP 9x3 1/2x3 3 C-1 3 -C2NP 9x6 3/4x3 6 C-2 5 -C3NP 9x9x3 9 C-3 7 -D1NP 11 1/4x3 1/2x3 4 D-1 4 -D3NP 11 1/4x9x3 12 D-3 8 -D4NP 11 1/4x11 1/4x3 16 D-4 9 -E1NP 13 1/2x3 1/2x3 5 E-1 5 -E4NP 13 1/2x11 1/4x3 20 E E5NP 13 1/2x13 1/2x3 25 E F1NP 15 3/4x3 1/2x3 6 F-1 6 -G1NP 19x3 1/2x3 7 G-1 6 -H1NP 21 1/4x3 1/2x3 8 H-1 8 -J1NP 23 1/2x3 1/2x3 9 J-1 8 -K1NP 25 3/4x3 1/2x3 10 K-1 8 Catalog Enclosure Weight Number Size (xxc) -1NP 3 1/2x3 1/2x3 2-1NP 6 3/4x3 1/2x3 2-2NP 6 3/4x6 3/4x3 4 -C1NP 9x3 1/2x3 3 -C2NP 9x6 3/4x3 5 -C3NP 9x9x3 7 -D1NP 11 1/4x3 1/2x3 4 -D3NP 11 1/4x9x3 8 -D4NP 11 1/4x11 1/4x3 9 -E1NP 13 1/2x3 1/2x3 5 -E4NP 13 1/2x11 1/4x3 11 -E5NP 13 1/2x13 1/2x3 13 -F1NP 15 3/4x3 1/2x3 6 -G1NP 19x3 1/2x3 6 -H1NP 21 1/4x3 1/2x3 8 -J1NP 23 1/2x3 1/2x3 8 -K1NP 25 3/4x3 1/2x3 8 Pushbutton & Consolets 113
114 USTIN EXTR DEEP PUSHUTTON ENCLOSURES ustin extra deep pushbutton enclosures are Underwriters Laboratories Listed and are designed to house standard oiltight switches, pilot lights, and stacked pushbutton units. They provide a degree of protection against dust, dirt, oil, and water. Construction: Fabricated from 14 gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. External mounting feet. Standard 4-way 30mm pushbutton holes. Cover held in place by captivated screws threaded into sealed wells. Finish: Pushbutton & Consolets Y 2.25 Y ustin extra deep pushbutton enclosures are provided standard with an NSI 61 gray polyester powder coating FRONT VIEW WITH COVER REMOVED C+.44 C Options: SECTION Y-Y HOLE RRNGEMENT Special materials. Special finishes C-1 C-2 C-3 D-1 D-3 D-4 E-2 E-4 E-5 F-5 F-6 H-2 Custom box size or construction. 4-way 22mm pushbutton holes. INDUSTRY STNDRDS UL 50 Types 4, 12 & 13 NEM Types 4, 12 & 13 CUL Types 4, 12 & 13
115 USTIN EXTR DEEP PUSHUTTON ENCLOSURES lank Cover Catalog Enclosure Holes Hole Weight Number Size (xxc) rrangement Catalog Enclosure Weight Number Size (xxc) -1DP 3 1/2x3 1/2x4 1/ DP 6 3/4x3 1/2x4 1/ DP 6 3/4x6 3/4x4 1/ C1DP 9x3 1/2x4 1/2 3 C-1 4 -C2DP 9x6 3/4x4 1/2 6 C-2 6 -C3DP 9x9x4 1/2 9 C-3 8 -D1DP 11 1/4x3 1/2x4 1/2 4 D-1 5 -D3DP 11 1/4x9x4 1/2 12 D-3 9 -D4DP 11 1/4x11 1/4x4 1/2 16 D E2DP 13 1/2x6 3/4x4 1/2 10 E-2 9 -E4DP 13 1/2x11 1/4x4 1/2 20 E E5DP 13 1/2x13 1/2x4 1/2 25 E F5DP 15 3/4x13 1/2x4 1/2 30 F F6DP 15 3/4x15 3/4x4 1/2 36 F H2DP 20 1/4x6 3/4x4 1/2 16 H DP 3 1/2x3 1/2x4 1/2 3-1DP 6 3/4x3 1/2x4 1/2 3-2DP 6 3/4x6 3/4x4 1/2 6 -C1DP 9x3 1/2x4 1/2 4 -C2DP 9x6 3/4x4 1/2 6 -C3DP 9x9x4 1/2 8 -D1DP 11 1/4x3 1/2x4 1/2 5 -D3DP 11 1/4x9x4 1/2 9 -D4DP 11 1/4x11 1/4x4 1/2 10 -E2DP 13 1/2x6 3/4x4 1/2 9 -E4DP 13 1/2x11 1/4x4 1/2 13 -E5DP 13 1/2x13 1/2x4 1/2 15 -F5DP 15 3/4x13 1/2x4 1/2 17 -F6DP 15 3/4x15 3/4x4 1/2 21 -H2DP 20 1/4x6 3/4x4 1/2 10 Pushbutton & Consolets 115
116 USTIN PENDNT PUSHUTTON ENCLOSURES ustin pendant pushbutton enclosures are Underwriters Laboratories Listed and are designed to house standard oiltight switches, pilot lights, and pushbutton switches. They provide a degree of protection against dust, dirt, oil, and water. Construction: Fabricated from 14 gauge steel. Has hub and hanger bracket at top for overhead wiring and support. Continuously welded and ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. Standard 4-way 30mm pushbutton holes. Cover held in place by captivated screws threaded into sealed wells. Finish: Pushbutton & Consolets DI ustin pendant pushbutton enclosures are provided standard with as NSI 61 gray polyester powder coating C Options: HOLE RRNGEMENT Special materials. Special finishes. Note: G-1 has.5 added on each side of center hole. H-1 has 1 added between the two center holes C-1 D-1 E-1 F-1 G-1 H-1 Custom box size or construction. 4-way 22mm pushbutton holes. INDUSTRY STNDRDS UL 50 Types 4, 12 & 13 NEM Types 4, 12 & 13 CUL Types 4, 12 & 13
117 USTIN PENDNT PUSHUTTON ENCLOSURES Catalog Enclosure Holes Hole Weight "" Conduit Number Size (xxc) rrangement Dimension Hub -1PP 3 7/8x2 1/2x2 3/ /2-1PP 6 1/8x2 1/2x2 3/ /4 3/4 -C1PP 8 3/8x2 1/2x2 3/8 3 C /2 3/4 -D1PP 10 5/8x2 1/2x2 3/8 4 D /4 3/4 -E1PP 12 7/8x2 1/2x2 3/8 5 E F1PP 15 1/8x2 1/2x2 3/8 6 F /4 1 -G1PP 18 3/8x2 1/2x2 3/8 7 G /2 1 -H1PP 20 5/8x2 1/2x2 3/8 8 H /4 1 1/4 Pushbutton & Consolets 117
118 USTIN SLIM-LINE PUSHUTTON ENCLOSURES ustin slim-line pushbutton enclosures are Underwriters Laboratories Listed and are designed to house oiltight switches, pilot lights, and pushbutton switches where space is limited. They provide a degree of protection from dust, dirt, oil, and water. Construction: Fabricated from 14 gauge steel. Cover is held in place by captivated screws threaded into sealed wells. External mounting feet. Standard 4-way 30mm pushbutton holes. Continuously welded seams and ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. Finish: Pushbutton & Consolets DI ustin slim-line pushbutton enclosures are provided standard with as NSI 61 gray polyester powder coating HOLE RRNGEMENT C Options: Special materials. Note: G-1 has.5 added on each side of center hole. H-1 has 1 added between the two center holes C-1 D-1 E-1 F-1 G-1 H-1 Special finishes. Custom box size or construction. 4-way 22mm pushbutton holes. INDUSTRY STNDRDS UL 50 Types 4, 12 & 13 NEM Types 4, 12 & 13 CUL Types 4, 12 & 13
119 USTIN SLIM-LINE PUSHUTTON ENCLOSURES Catalog Enclosure Holes Hole Weight Number Size (xxc) rrangement -1MP 3 7/8x2 1/2x2 3/ MP 6 1/8x2 1/2x2 3/ C1MP 8 3/8x2 1/2x2 3/8 3 C-1 2 -D1MP 10 5/8x2 1/2x2 3/8 4 D-1 3 -E1MP 12 7/8x2 1/2x2 3/8 5 E-1 3 -F1MP 15 1/8x2 1/2x2 3/8 6 F-1 4 -G1MP 18 3/8x2 1/2x2 3/8 7 G-1 4 -H1MP 20 5/8x2 1/2x2 3/8 8 H-1 8 Pushbutton & Consolets 119
120 USTIN NEM 4X PUSHUTTON ENCLOSURES ustin NEM 4X pushbutton enclosures are Underwriters Laboratories Listed and are designed to house oiltight switches, pilot lights, and pushbutton switches. They provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose directed water, and damage from external ice formation. They are also designed for use in areas where corrosion is a serious problem. Construction: Fabricated from 14 gauge Type 304 steel. Cover is held in place by captivated screws threaded into sealed wells. External mounting feet. Standard 4-way 30mm pushbutton holes. Continuously welded seams and ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. Pushbutton & Consolets Y Y Finish: ustin NEM 4X pushbutton enclosures are provided standard in Type 304 stainless steel FRONT VIEW WITH COVER REMOVED C+.44 C Options: Type 316 stainless steel. SECTION Y-Y -1-1 HOLE RRNGEMENT Custom box size or construction. 4-way 22mm pushbutton holes. C-1 C-2 C-3 D-1 D-3 D-4 INDUSTRY STNDRDS UL 50 Types 4, 12 & 13 NEM Types 4, 12 & 13 CUL Types 4, 12 & 13
121 USTIN NEM 4X PUSHUTTON ENCLOSURES Catalog Enclosure Holes Hole Weight Number Size (xxc) rrangement -1FP 3 1/2x3 1/2x FP 6 3/4x3 1/2x C1FP 9x3 1/2x3 3 C-1 3 -C2FP 9x6 3/4x3 6 C-2 6 -C3FP 9x9x3 9 C-3 7 -D1FP 11 1/4x3 1/2x3 4 D-1 4 -D3FP 11 1/4x9x3 12 D-3 8 -D4FP 11 1/4x11 1/4x3 16 D-4 10 Pushbutton & Consolets 121
122 USTIN EXTR LRGE HINGE COVER PUSH UTTON ENCLOSURES WITH CK ustin extra large hinge cover oiltight pushbutton enclosures are Underwriters Laboratories Listed and are designed to house oiltight switches, pilot lights, and pushbutton switches. They provide a degree of protection against dust, dirt, oil, and water. Construction: Fabricated from 14 gauge steel. Cover held in place by captivated screws threaded into sealed wells and a continuous hinge. Continuously welded seams ground smooth. Standard back panel. External mounting feet. Standard 4-way 30mm pushbutton holes. Neoprene gasket attached to cover with oil resistant adhesive..31 DI. Finish: Pushbutton & Consolets Y Y ustin hinge cover oiltight pushbutton enclosures are provided standard with an NSI 61 gray polyester powder coating. ack panels are painted white FRONT VIEW WITH NO COVER ND NO HINGE C+.38 C.50 Options: Special materials. SECTION Y-Y Special finishes. HOLE RRNGEMENT Custom box size or construction. C-2 C-3 D-3 D-4 4-way 22mm pushbutton holes. E-4 E-5 F-5 F-6 HOLE RRNGEMENT INDUSTRY STNDRDS UL 50 Type 12 & 13 NEM Type 12 & 13 CUL Type 12 & 13
123 USTIN EXTR LRGE HINGE COVER PUSHUTTON ENCLOSURES WITH CK Catalog Enclosure Holes Hole Weight Number Size (xxc) rrangement -C2XP 9x6 3/4x6 1/4 6 C C3XP 9x9x6 1/4 9 C D3XP 11 1/4x9x6 1/4 12 D D4XP 11 1/4x11 1/4x6 1/4 16 D E4XP 13 1/2x11 1/4x6 1/4 20 E E5XP 13 1/2x13 1/2x6 1/4 25 E F5XP 15 3/4x13 1/2x6 1/4 30 F F6XP 15 3/4x15 3/4x6 1/4 36 F-6 27 Pushbutton & Consolets 123
124 USTIN SLOPING PUSHUTTON ENCLOSURES ustin sloping pushbutton enclosures are Underwriters Laboratories Listed and are designed to house standard oiltight switches, pilot lights, and pushbutton switches where slanted control surfaces are desired. They provide a degree of protection against dust, dirt, oil, and water. Construction: Fabricated from 14 gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. External mounting feet. Standard 4-way 30mm pushbutton holes. Cover held in place by captivated screws threaded into sealed wells. Pushbutton & Consolets G D D Finish: ustin sloping pushbutton enclosures are provided standard with an NSI 61 gray polyester powder coating. F VIEW X-X.31 DI. SECTION Y-Y X-X C Y 2.50 Y SCREW w/rivnut Options: Special materials. HOLE RRNGEMENT Special finishes way 22mm pushbutton holes C-3 D-3 D-4 D-5 E-5 E-6 INDUSTRY STNDRDS UL 50 Types 4, 12 & 13 NEM Types 4, 12 & 13 CUL Types 4, 12 & 13
125 USTIN SLOPING PUSHUTTON ENCLOSURES Catalog Enclosure Holes Hole Weight "F" "G" Number Size (xxc) rrangement -1SP 3 1/2x3 1/4x4 7/ /4 1 5/8-2SP 3 1/2x5 1/2x4 7/ /4 1 5/8-3SP 3 1/2x7 3/4x4 7/ /4 1 5/8-4SP 3 1/2x10x4 7/ /4 1 5/8-2SP 7 1/4x6 1/4x6 3/ /2 2-3SP 7 1/4x8 1/2x6 3/ /2 2-4SP 7 1/4x10 3/4x6 3/ /2 2-5SP 7 1/4x13x6 3/ /2 2-6SP 7 1/4x15 1/4x6 3/ /2 2-8SP 7 1/4x19 3/4x6 3/ /2 2 -C3SP 9 1/2x8 1/2x7 7/8 9 C /2 2 -D3SP 11 3/4x8 1/2x9 12 D /2 2 -D4SP 11 3/4x10 3/4x9 16 D /2 2 -D5SP 11 3/4x13x9 20 D /2 2 -E5SP 14x13x10 1/8 25 E /2 2 -E6SP 14x15 1/4x10 1/8 30 E /2 2 Pushbutton & Consolets 125
126 USTIN OILTIGHT CONSOLETS ND PEDESTLS ustin Oiltight Consolets are Underwriters Laboratories Listed and are designed to house electrical controls and instruments. The consolet can be mounted on machines, desk tops, or ustin consolet pedestals. It can also be mounted to give a control surface incline of 30º or 60º angle. They provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. Construction: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Cover attached by captivated screws threaded into sealed wells and continuous hinge on opposite side. Neoprene gasket attached to cover with oil resistant adhesive. Finish: Pushbutton & Consolets ustin Oiltight Consolets are provided standard with an NSI 61 gray polyester powder coating. Options: Special materials. Special finishes. INDUSTRY STNDRDS UL 50 Type 12 & 13 NEM Type 12 & 13 (except for mounting provisions) CUL Type 12 & 13
127 USTIN OILTIGHT CONSOLETS ND PEDESTLS ustin Pedestals and ases allow the consolets to be floor mounted. Wiring can be installed through the base, access opening in pedestal, or directly into the consolet. Construction: ox connector fitting, a neoprene gasket on column flange, and screws are provided to attach the consolet to the pedestal. Pedestal fabricated from 14 gauge steel. ase fabricated from 10 gauge steel. Finish: ustin pedestals and bases are provided standard with an NSI 61 gray polyester powder coating. Pushbutton & Consolets Options: Special materials. Special finishes. 127
128 USTIN OILTIGHT CONSOLETS ND PEDESTLS.312 TYP D.312 DI. TYP E.813 OMIT MIDDLE HOLES FOR 4x4 Pushbutton & Consolets PEDESTL CCESS PLTE CCESS OPENING F G DI. TYP J H TYP SE C C INDUSTRY STNDRDS UL 50 Type 12 & 13 NEM Type 12 & 13 (except for mounting provisions) CUL Type 12 & 13
129 USTIN OILTIGHT CONSOLETS ND PEDESTLS Y SCREW w/rivnut D 30 Y.56 C SECTION Y-Y CONTINUOUS HINGE Pushbutton & Consolets Oiltight Consolets Catalog Enclosure "D" Weight Catalog Enclosure "D" Weight Number Size (xxc) Dimension Number Size (xxc) Dimension -88PC 8x8x7 5/32 7 7/ PC 16x16x11 5/ / PC 8x12x7 5/32 7 7/ PC 16x20x11 5/ / PC 8x16x7 5/32 7 7/ PC 16x24x11 5/ / PC 8x20x7 5/32 7 7/ PC 16x / / PC 16x36x11 5/ / PC 12x12x9 5/ / PC 12x16x9 5/ / PC 20x20x13 5/ / PC 12x20x9 5/ / PC 20x24x13 5/ / PC 12x24x9 5/ / PC 20x30x13 5/ /8 51 Pedestals and ases Catalog Description "D" "E" "F" "G" "H" "J" Weight Catalog Description Weight Number (x) Number (CxC) -44PS 4x4 Pedestal x18 ase 20-66PS 6x6 Pedestal x24 ase
130 USTIN SCREW COVER TROUGHS ustin screw cover troughs are Underwriters Laboratories Listed for use of indoor wiring. Construction: Fabricated in accordance with UL specifications from code gauge steel. End caps spot welded in. Single sheet steel for body. Cover attached by screws. Finish: Wireways & Trough Products.750 SECTION VIEW ustin screw cover troughs are provided standard in galvanized steel. n NSI 61 gray polyester powder coating over CRS is available on request. 12" MX Options: C ENDS SPOT WELDED IN Special knockouts or knockout arrangements. Special materials. Special finishes. Custom trough size or construction. INDUSTRY STNDRDS UL 870 NEM Type 1 CUL 870
131 USTIN SCREW COVER TROUGHS Catalog Trough Weight Catalog Trough Weight Number Size (xxc) Number Size (xxc) -4412ST 4x4x ST 8x8x ST 4x4x ST 8x8x ST 4x4x ST 8x8x ST 4x4x ST 8x8x ST 4x4x ST 8x8x ST 4x4x ST 8x8x ST 4x4x ST 8x8x ST 4x4x ST 10x10x ST 6x6x ST 10x10x ST 6x6x ST 10x10x ST 6x6x ST 10x10x ST 6x6x ST 10x10x ST 6x6x ST 10x10x ST 6x6x ST 10x10x ST 6x6x ST 6x6x ST 12x12x ST 12x12x ST 12x12x ST 6x4x ST 12x12x ST 6x4x ST 12x12x ST 6x4x ST 12x12x ST 12x12x ST 8x6x ST 8x6x ST 18x18x ST 8x6x ST 18x18x ST 8x6x ST 18x18x ST 8x6x ST 18x18x Replace "ST" Suffix with: STG: Screw Cover Trough Gray Wireways & Trough Products 131
132 USTIN HINGE COVER TROUGHS ustin hinge cover troughs are Underwriters Laboratories Listed for use of indoor wiring. Construction: Fabricated in accordance with UL specifications from code gauge steel. End caps spot welded in. Single sheet steel for body. Cover attached to trough with butt hinges one side and screws on opposite side. Finish: Wireways & Trough Products UTT HINGE ustin hinge cover troughs are provided standard in galvanized steel. n NSI 61 gray polyester powder coating over CRS is available on request. SECTION VIEW Options: C ENDS SPOT WELDED IN Special knockouts or knockout arrangements. Special materials. Special finishes. Custom trough size or construction. INDUSTRY STNDRDS UL 870 NEM Type 1 CUL 870
133 USTIN HINGE COVER TROUGHS Catalog Trough Weight Catalog Trough Weight Number Size (xxc) Number Size (xxc) -4412HT 4x4x HT 8x8x HT 4x4x HT 8x8x HT 4x4x HT 8x8x HT 4x4x HT 8x8x HT 4x4x HT 8x8x HT 4x4x HT 8x8x HT 4x4x HT 4x4x HT 10x10x HT 10x10x HT 6x6x HT 10x10x HT 6x6x HT 10x10x HT 6x6x HT 10x10x HT 6x6x HT 10x10x HT 6x6x HT 10x10x HT 6x6x HT 6x6x HT 6x6x HT 12x12x HT 12x12x HT 6x4x HT 12x12x HT 6x4x HT 12x12x HT 6x4x HT 12x12x HT 12x12x HT 8x6x HT 12x12x HT 8x6x HT 8x6x HT 8x6x HT 18x18x HT 8x6x HT 18x18x HT 18x18x HT 8x8x HT 18x18x Replace "HT" Suffix with: HTG: Hinge Cover Trough Gray Wireways & Trough Products 133
134 USTIN SCREW COVER GSKETED TROUGHS ustin gasketed screw cover troughs are Underwriters Laboratories Listed and are designed to protect from rain, sleet, or snow in outdoor use. Indoor use, gasketed troughs protect from dust and moisture. Construction: Fabricated in accordance with UL specifications from code gauge steel. Continuously welded seams ground smooth. Neoprene gasket attached to cover with oil resistant adhesive. Finish: Wireways & Trough Products.75 GSKET ustin gasketed screw cover troughs are constructed standard in galvanized steel. n NSI 61 gray polyester powder coating over phosphatized surfaces is available on request. SEMS WELDED SOLID ND GROUND SMOOTH SECTION VIEW 6" MX Options: Special materials. C Special finishes. Custom trough size or construction. INDUSTRY STNDRDS UL 870 NEM Type 3 & 12 CUL 870
135 USTIN SCREW COVER GSKETED TROUGHS Catalog Trough Weight Catalog Trough Weight Number Size (xxc) Number Size (xxc) -4412GST 4x4x GST 8x8x GST 4x4x GST 8x8x GST 4x4x GST 8x8x GST 4x4x GST 4x4x GST 10x10x GST 4x4x GST 10x10x GST 4x4x GST 10x10x GST 4x4x GST 10x10x GST 10x10x GST 6x6x GST 10x10x GST 6x6x GST 10x10x GST 6x6x GST 6x6x GST 12x12x GST 6x6x GST 12x12x GST 6x6x GST 12x12x GST 6x6x GST 12x12x GST 6x6x GST 12x12x GST 6x6x GST 12x12x GST 12x12x GST 8x8x GST 8x8x GST 18x18x GST 8x8x GST 18x18x GST 8x8x GST 18x18x GST 8x8x GST 18x18x Replace "GST" Suffix with: GSTG: Gasketed Screw Cover Trough Gray Wireways & Trough Products 135
136 USTIN RINPROOF TROUGHS ustin rainproof troughs are Underwriters Laboratories Listed and are designed to provide a degree of protection against rain, sleet, and snow in outdoor use. Indoor use, rainproof troughs protect from dripping water. Construction: Fabricated in accordance with UL specifications from code gauge steel. Dripshield along top of trough. Slip-on cover attached by screws at bottom edge. Embossed mounting holes on back. Finish: Wireways & Trough Products FRONT COVER SLIDES UNDER TOP FLNGE TOP SECTION THRU SIDE FRONT COVER SECTION THRU TOP ustin rainproof troughs are provided standard in galvanized. n NSI 61 gray polyester powder coating over phosphatized surfaces is available on request. Options: C Special knockouts or knockout arrangements in bottom only. Special materials. Special finishes. Custom trough size or construction. INDUSTRY STNDRDS UL 870 NEM Type 3R CUL 870
137 USTIN RINPROOF TROUGHS Catalog Trough Weight Catalog Trough Weight Number Size (xxc) Number Size (xxc) -4412RT 4x4x RT 8x8x RT 4x4x RT 8x8x RT 4x4x RT 8x8x RT 4x4x RT 8x8x RT 4x4x RT 8x8x RT 4x4x RT 4x4x RT 10x10x RT 4x4x RT 10x10x RT 4x4x RT 10x10x RT 4x4x RT 10x10x RT 10x10x RT 6x6x RT 10x10x RT 6x6x RT 10x10x RT 6x6x RT 10x10x RT 6x6x RT 6x6x RT 12x12x RT 6x6x RT 12x12x RT 6x6x RT 12x12x RT 6x6x RT 12x12x RT 6x6x RT 12x12x RT 12x12x RT 8x8x RT 12x12x RT 8x8x RT 12x12x RT 8x8x48 31 NOTE: Replace "RT" Suffix with: RTG: Rainproof Trough Gray Wireways & Trough Products 137
138 JIC OILTIGHT SCREW COVER TROUGHS ustin JIC screw cover troughs are Underwriters Laboratories Listed and are designed to provide a degree of protection against dust, dirt, oil, and water. Construction: Cover and body fabricated from 14 gauge steel. Continuously welded seams ground smooth. Cover held in place by captivated screws threaded into sealed wells. Neoprene gasket attached to cover with oil resistant adhesive. External mounting feet. Finish: Wireways & Trough Products GSKET ustin JIC screw cover troughs are provided standard with an NSI 61 gray polyester powder coating. SECTION VIEW SEMS WELDED SOLID GROUND SMOOTH CPTIVTED SCREWS w/seled WELLS. QUNTITY & LOCTION VRY w/length Options: Special materials. Special finishes. C Custom trough size or construction. INDUSTRY STNDRDS UL 870 NEM Type 12 CUL 870
139 JIC OILTIGHT SCREW COVER TROUGHS Catalog Trough Weight Catalog Trough Weight Number Size (xxc) Number Size (xxc) -4412JTS 4x4x JTS 8x8x JTS 4x4x JTS 4x4x JTS 10x10x JTS 4x4x JTS 10x10x JTS 10x10x JTS 6x6x JTS 10x10x JTS 6x6x JTS 10x10x JTS 6x6x JTS 10x10x JTS 6x6x JTS 6x6x JTS 6x6x JTS 12x12x JTS 12x12x JTS 8x8x JTS 12x12x JTS 8x8x JTS 12x12x JTS 8x8x JTS 12x12x JTS 8x8x JTS 12x12x96 99 Wireways & Trough Products 139
140 JIC OILTIGHT HINGE COVER TROUGHS ustin JIC oiltight hinge cover troughs are Underwriters Laboratories Listed and are designed to provide a degree of protection against dust, dirt, oil, and water. Construction: Cover and body fabricated from 14 gauge steel. Cover held in place by external quick release clamps on one side and butt hinges on opposite side. Neoprene gasket attached to cover with oil resistant adhesive. External mounting feet. Continuously welded ends and seams ground smooth. Finish: Wireways & Trough Products QUICK RELESE LTCH GSKET UTT HINGE ustin JIC oiltight troughs are provided standard with an NSI 61 gray polyester powder coating. SEMS WELDED SOLID GROUND SMOOTH SECTION VIEW CLMP/FEET QUNTITY & LOCTION VRY WITH SIZE C Options: Special materials. Special finishes. Custom trough size or construction INDUSTRY STNDRDS UL 870 NEM Type 12 CUL 870
141 JIC OILTIGHT HINGE COVER TROUGHS Catalog Trough Weight Catalog Trough Weight Number Size (xxc) Number Size (xxc) -2212JTR 2 1/2x2 1/2x JTR 6x6x JTR 2 1/2x2 1/2x JTR 6x6x JTR 2 1/2x2 1/2x JTR 6x6x JTR 2 1/2x2 1/2x JTR 6x6x JTR 2 1/2x2 1/2x JTR 6x6x JTR 2 1/2x2 1/2x JTR 6x6x JTR 2 1/2x2 1/2x JTR 6x6x JTR 2 1/2x2 1/2x JTR 4x4x JTR 8x8x JTR 4x4x JTR 8x8x JTR 4x4x JTR 8x8x JTR 4x4x JTR 8x8x JTR 4x4x JTR 8x8x JTR 4x4x JTR 4x4x JTR 12x12x JTR 4x4x JTR 12x12x JTR 12x12x JTR 6x6x JTR 12x12x60 73 Wireways & Trough Products 141
142 NEM 1 SCREW COVER WIREWYS ustin NEM 1 screw cover wireway is Underwriters Laboratories Listed and is designed for use in housing electrical wiring. It provides a degree of protection against limited amounts of falling dirt. Fittings can be opened on any side to permit the laying in of entire runs of wiring. Construction: Fabricated in accordance with UL specifications from code gauge steel. Wireway is furnished with or without knockouts. Cover has keyhole slots to permit easy removal without removing screws. Single sheet steel for body. Finish: Wireways & Trough Products C SCREW QUNTITY & LOCTION VRY WITH LENGTH ustin NEM 1 screw cover wireway is provided standard in galvanized steel. n NSI 61 gray polyester powder coating over CRS is available on request. WIREWY CONSTRUCTED TO INSIDE DIMENSIONS QUNTITY OF CONNECTOR HOLES VRY WITH SIZE END VIEW KNOCKOUT PTTERN FOR 2.5 x 2.5 1/2"-3/4" COMINTION KNOCKOUT PTTERN FOR 4 x 4 & 6 x 6 1/2"-3/4" & 1"-1 1/4" COMINTION 4.00 Options: Special knockouts or knockout arrangements. Special materials. Special finishes. INDUSTRY STNDRDS UL 870 NEM Type 1 CUL 870
143 NEM 1 SCREW COVER WIREWYS Catalog Wireway Weight Catalog Wireway Weight Catalog Wireway Weight Number Size (xxc) Number Size (xxc) Number Size (xxc) Description Description Description -2212SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 2 1/2x2 1/2x SW 6x6x SW 10x10x SW 4x4x SW 8x8x SW 12x12x SW 4x4x SW 8x8x SW 12x12x SW 4x4x SW 8x8x SW 12x12x SW 4x4x SW 8x8x SW 12x12x SW 4x4x SW 8x8x SW 12x12x SW 4x4x SW 8x8x SW 12x12x SW 4x4x SW 8x8x SW 12x12x SW 4x4x SW 8x8x SW 12x12x SW 4x4x SW 8x8x SW 12x12x EP End Cap.3-66EP End Cap EP End Cap TE Tee 2-66TE Tee TE Tee 20-22L90 90 Elbow 2-66L90 90 Elbow L90 90 Elbow 18-22UC U-Connector.3-66UC U-Connector UC U-Connector 2-22P Panel dapter.5-66p Panel dapter P Panel dapter 3-22L45 45 Elbow 2-66L45 45 Elbow L45 45 Elbow 14-22UH U-Hanger 2-66UH U-Hanger UH U-Hanger 5-22X Cross 4-66X Cross X Cross 20-22TS Telescope 3-64R Reducer 2-108R Reducer 2-66TS Telescope TS Telescope 12-44EP End Cap.5-88EP End Cap EP End Cap 3-44TE Tee 5-88TE Tee TE Tee 26-44L90 90 Elbow 5-88L90 90 Elbow L90 90 Elbow 24-44UC U-Connector.3-88UC U-Connector UC U-Connector 2-44P Panel dapter 1-88P Panel dapter P Panel dapter 3-44L45 45 Elbow 4-88L45 45 Elbow L45 45 Elbow 19-44UH U-Hanger 2-88UH U-Hanger UH U-Hanger 6-44X Cross 6-88X Cross X Cross 24-42R Reducer.5-86R Reducer R Reducer 2-44TS Telescope 5-88TS Telescope TS Telescope 15 Replace "SW" Suffix with: SWG: Screw Cover Wireway Gray SWGK: Screw Cover Wireway Gray w/ko's SWK: Screw Cover Wireway w/ko's Wireways & Trough Products 143
144 NEM 1 HINGE COVER WIREWYS ustin NEM 1 hinge cover wireway is Underwriters Laboratories Listed and is designed for use in housing electrical wiring. It provides a degree of protection against limited amounts of falling dirt. Fittings can be opened on any side to permit the laying in of entire runs of wiring. Construction: Fabricated in accordance with UL specifications from code gauge steel. Wireway sizes 2.5x2.5, 4x4, and 6x6 have formed hinges. Single sheet steel for body. Wireway can be furnished with or without knockouts. Wireway sizes 8x8, 10x10, and 12x12 have butt hinges. Cover is held in place by screws on opposite side of hinge. Finish: Wireways & Trough Products C - WIREWY CONSTRUCTED TO INSIDE DIMENSIONS SCREW QUNTITY & LOCTION VRY WITH LENGTH ustin NEM 1 hinge cover wireway is provided standard in galvanized steel. n NSI 61 gray polyester powder coating over CRS is available on request. HINGE QUNTITY OF CONNECTOR HOLES VRY WITH SIZE 4.00 END VIEW KNOCKOUT PTTERN FOR 2.5 x 2.5 1/2"-3/4" COMINTION Options: Special knockouts or knockout arrangements. Special materials. Special finishes KNOCKOUT PTTERN FOR 4 x 4 & 6 x 6 1/2"-3/4" & 1"-1 1/4" COMINTION INDUSTRY STNDRDS UL 870 NEM Type 1 CUL 870
145 NEM 1 HINGE COVER WIREWYS Catalog Wireway Weight Catalog Wireway Weight Catalog Wireway Weight Number Size (xxc) Number Size (xxc) Number Size (xxc) Description Description Description -2212HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 2 1/2x2 1/2x HW 6x6x HW 10x10x HW 4x4x HW 8x8x HW 12x12x HW 4x4x HW 8x8x HW 12x12x HW 4x4x HW 8x8x HW 12x12x HW 4x4x HW 8x8x HW 12x12x HW 4x4x HW 8x8x HW 12x12x HW 4x4x HW 8x8x HW 12x12x HW 4x4x HW 8x8x HW 12x12x HW 4x4x HW 8x8x HW 12x12x HW 4x4x HW 8x8x HW 12x12x EP End Cap.3-66EP End Cap EP End Cap TE Tee 2-66TE Tee TE Tee 20-22L90 90 Elbow 2-66L90 90 Elbow L90 90 Elbow 18-22UC U-Connector.3-66UC U-Connector UC U-Connector 2-22P Panel dapter.5-66p Panel dapter P Panel dapter 3-22L45 45 Elbow 2-66L45 45 Elbow L45 45 Elbow 14-22UH U-Hanger 2-66UH U-Hanger UH U-Hanger 5-22X Cross 4-66X Cross X Cross 20-22TS Telescope 3-64R Reducer 2-108R Reducer 2-66TS Telescope TS Telescope 12-44EP End Cap.5-88EP End Cap EP End Cap 3-44TE Tee 5-88TE Tee TE Tee 26-44L90 90 Elbow 5-88L90 90 Elbow L90 90 Elbow 24-44UC U-Connector.3-88UC U-Connector UC U-Connector 2-44P Panel dapter 1-88P Panel dapter P Panel dapter 3-44L45 45 Elbow 4-88L45 45 Elbow L45 45 Elbow 19-44UH U-Hanger 2-88UH U-Hanger UH U-Hanger 6-44X Cross 6-88X Cross X Cross 24-42R Reducer.5-86R Reducer R Reducer 2-44TS Telescope 5-88TS Telescope TS Telescope 15 Replace "HW" Suffix with: HWG: Hinge Cover Wireway Gray HWGK: Hinge Cover Wireway Gray w/ko's HWK: Hinge Cover Wireway w/ko's Wireways & Trough Products 145
146 NEM 1 WIREWY FITTINGS C E TEE llows runs of wireway to split off or come together at a 90 angle E Wireways & Trough Products 6.00 CROSS llows runs of wireway to intersect and cross or split off at 90 angles TELESCOPE Length easily adjusts from 6" to 11". No cutting or welding is required D C C 45 ELOW Similar to the 90 elbow but only makes a 45 turn 90 ELOW ny side can be removed to retain the lay-in feature of the wireway. Sides are held in place with screws
147 NEM 1 WIREWY FITTINGS Wireway Size C D E F G 2 1/2x2 1/2 2 1/2 2 1/ /2 N N 4x / /2 2 1/2 6x / x / x / x / PNEL DPTER llows a run of wireway to be securely connected to an enclosure U-CONNECTOR U-Connectors are used to join sections of wireway together. These must be ordered separately. G UNIVERSL HNGER llows runs of wireway to be supported from either the ceiling or the wall REDUCER llows the reduction of a run of wireway to a smaller wireway size F END CP Used to close off the end of a wireway run Wireways & Trough Products 147
148 JIC PULL-THROUGH WIREWY ustin JIC Pull-Through wireway is Underwriters Laboratories Listed and is designed to protect electrical wiring from dust, dirt, oil, and water. Construction: Fabricated in accordance with UL specifications from 14 gauge steel. Continuously welded seams. Neoprene gasket attached to cover with oil-resistant adhesive. Cover attached to body with heavy butt hinges and quick release clamps. One piece oil-resistant gasket is provided with each straight section and fitting for bolting sections together. Finish: Wireways & Trough Products CONNECTING HOLES VRY WITH SIZE ustin JIC Pull- Through wireway is provided standard with an NSI 61 gray polyester powder coating inside and out. C LTCH QUNTITY & LOCTION VRY WITH SIZE QUICK RELESE LTCH GSKET UTT HINGE Options: Special materials. Special finishes. SECTION VIEW INDUSTRY STNDRDS UL 870 NEM Type 12 CUL 870
149 JIC PULL-THROUGH WIREWY Catalog Wireway Weight Catalog Wireway Weight Number Size (xxc) Number Size (xxc) Description Description -2212JW 2 1/2x2 1/2x JW 6x6x JW 2 1/2x2 1/2x JW 6x6x JW 2 1/2x2 1/2x JW 6x6x JW 2 1/2x2 1/2x JW 6x6x JW 2 1/2x2 1/2x JW 6x6x JW 2 1/2x2 1/2x JW 6x6x JL90 90 Elbow 3-66JL90 90 Elbow 8-22JL45 45 Elbow 2-66JL45 45 Elbow 6-22JTE Tee 4-66JTE Tee 10-22JX Cross 5-66JX Cross 13-22JTSC Telescope 4-66JTSC Telescope 11 N Reducer -64JR Reducer 2-22JF ox Fitting 1-66JF ox Fitting 1-22JCF Cut-off Fitting 3-66JCF Cut-off Fitting 8-22JN1 Nipple 1" 1-66JN1 Nipple 1" 3-22JN2 Nipple 2" 1-66JN2 Nipple 2" 3-22JN3 Nipple 3" 2-66JN3 Nipple 3" 4-22JH racket Hanger 1-66JH racket Hanger 3-22JDH Drop Hanger 1-66JDH Drop Hanger 2-22JEP End Plate 1-66JEP End Plate 3-22JG Gasket -66JG Gasket -4412JW 4x4x JW 8x8x JW 4x4x JW 8x8x JW 4x4x JW 8x8x JW 4x4x JW 8x8x JW 4x4x JW 8x8x JW 4x4x JW 8x8x JL90 90 Elbow 5-88JL90 90 Elbow 12-44JL45 45 Elbow 3-88JL45 45 Elbow 9-44JTE Tee 6-88JTE Tee 15-44JX Cross 8-88JX Cross 18-44JTSC Telescope 7-88JTSC Telescope 15-42JR Reducer 1-86JR Reducer 3-44JF ox Fitting 1-88JF ox Fitting 2-44JCF Cut-off Fitting 6-88JCF Cut-off Fitting 11-44JN1 Nipple 1" 2-88JN1 Nipple 1" 4-44JN2 Nipple 2" 2-88JN2 Nipple 2" 4-44JN3 Nipple 3" 2-88JN3 Nipple 3" 5-44JH racket Hanger 1-88JH racket Hanger 6-44JDH Drop Hanger 1-88JDH Drop Hanger 6-44JEP End Plate 1-88JEP End Plate 4-44JG Gasket -88JG Gasket Wireways & Trough Products 149
150 JIC PULL-THROUGH WIREWY FITTINGS C 90 ELOW llows a wireway run to turn at a 90 angle D D Wireways & Trough Products CROSS llows runs of wireway to intersect and cross or split off at 90 angles TELESCOPE llows easy adjustment for up to 12" E CUT-OFF FITTING llows user to cut off part of fitting and weld on flange to form a section between 1" and 12" D C 45 ELOW Similar to a 90 elbow but only makes a 45 turn TEE llows runs of wireway to split off or come together at a 90 angle
151 JIC PULL-THROUGH WIREWY FITTINGS Wireway Size C D E F G K M R S T 2 1/2x2 1/2 2 1/2 2 1/2 6 1/2 10 1/2 3 3/8 N N 11 3/4 4 5/ /2 4x /2 2 1/2 13 1/4 6 1/8 5 1/2 5 1/2 6 6x /8 4, 2 1/2 4, 2 1/2 15 1/4 8 1/8 7 1/2 5 1/2 8 8x /8 6,4,2 1/2 6,4,2 1/2 19 1/4 10 1/8 9 1/2 5 1/2 10 M R L S T K NIPPLE vailable in 1", 2", and 3" lengths END PLTE Used to close off the end of a wireway run RCKET HNGER llows a run of wireway to be attached to the wall, ceiling, or floor G DROP HNGER llows a run of wireway to be suspended from the ceiling OX FITTING Used when wireway enters an enclosure on the inside of the enclosure to provide a tight seal GSKET Neoprene gasket used to provide a water tight seal between sections of wireway or between sections of wireway and fittings F REDUCER llows reduction of a wireway run to a smaller wireway size Wireways & Trough Products 151
152 JIC PULL-THROUGH WIREWY NEM 4X ustin JIC Pull-Through NEM 4X wireway is Underwriters Laboratories Listed and is designed to protect electrical wiring from dust, dirt, oil, and water. Construction: Fabricated in accordance with UL specifications from 14 gauge Type 304 stainless steel. Continuously welded seams. Neoprene gasket attached to cover with oil-resistant adhesive. Cover attached to body with heavy butt hinges and quick release clamps. One piece oil-resistant gasket is provided with each straight section and fitting for bolting sections together. Finish: SCREW CLMP GSKET UTT HINGE ustin JIC Pull-Through 4X wireway is provided standard in Type 304 stainless steel. Wireways & Trough Products SECTION VIEW LTCH QUNTITY & LOCTION VRY WITH SIZE C CONNECTING HOLES VRY WITH SIZE Options: Type 316 stainless steel INDUSTRY STNDRDS UL 870 NEM Type 4, 4X & 12 CUL 870
153 JIC PULL-THROUGH WIREWY NEM 4X Catalog Wireway Weight Catalog Wireway Weight Number Size (xxc) Number Size (xxc) Description Description -4412JWFX 4x4x JWFX 6x6x JWFX 4x4x JWFX 6x6x JWFX 4x4x JWFX 6x6x JWFX 4x4x JWFX 6x6x JWFX 4x4x JWFX 6x6x JWFX 4x4x JWFX 6x6x JL90X 90 Elbow 5-66JL90X 90 Elbow 8-44JL45X 45 Elbow 3-66JL45X 45 Elbow 6-44JTEX Tee 6-66JTEX Tee 10-44JXX Cross 8-66JXX Cross 13-44JTSX Telescope 7-66JTSX Telescope 11-42JRX Reducer 1-64JRX Reducer 2-44JFX ox Fitting 1-66JFX ox Fitting 1-44JCFX Cut-off Fitting 6-66JCFX Cut-off Fitting 8-44JN1X Nipple 1" 2-66JN1X Nipple 1" 3-44JN2X Nipple 2" 2-66JN2X Nipple 2" 3-44JN3X Nipple 3" 2-66JN3X Nipple 3" 4-44JHX racket Hanger 1-66JHX racket Hanger 3-44JDHX Drop Hanger 1-66JDHX Drop Hanger 2-44JEPX End Plate 1-66JEPX End Plate 3-44JG Gasket -66JG Gasket Wireways & Trough Products 153
154 JIC LY-IN WIREWY ustin JIC Lay-In wireway is Underwriters Laboratories Listed and is designed to protect electrical wiring from dust, dirt, oil, and water. ll sections and fittings are completely open on one side to allow a complete run of wiring to be laid into the wireway run. Construction: Fabricated in accordance with UL specifications from 14 gauge steel. Continuously welded seams. Neoprene gasket attached to cover with oil-resistant adhesive. One piece oil-resistant gasket and flat sealing plate (not shown) are provided with each straight section and fitting and a 90º sealing plate with each end plate for bolting sections together. Cover attached to body with heavy butt hinges and quick release clamps. Finish: Wireways & Trough Products ustin JIC Lay-In wireway is provided standard with an NSI 61 gray polyester powder coating inside and out. CONNECTING HOLES VRY WITH SIZE C LTCH QUNTITY & LOCTION VRY WITH SIZE QUICK RELESE LTCH GSKET UTT HINGE Options: Special materials. Special finishes. SECTION VIEW INDUSTRY STNDRDS UL 870 NEM Type 12 CUL 870
155 JIC LY-IN WIREWY Catalog Wireway Catalog Wireway Catalog Wireway Catalog Wireway Number Size (xxc) Number Size (xxc) Number Size (xxc) Number Size (xxc) Description Description Description Description -2212LW 2 1/2x2 1/2x LW 4x4x LW 6x6x LW 8x8x LW 2 1/2x2 1/2x LW 4x4x LW 6x6x LW 8x8x LW 2 1/2x2 1/2x LW 4x4x LW 6x6x LW 8x8x LW 2 1/2x2 1/2x LW 4x4x LW 6x6x LW 8x8x LW 2 1/2x2 1/2x LW 4x4x LW 6x6x LW 8x8x LW 2 1/2x2 1/2x LW 4x4x LW 6x6x LW 8x8x120-22LL90T 90L Outside open -44LL90T 90L Outside open -66LL90T 90L Outside open -88LL90T 90L Outside open -22LL90N 90L Inside open -44LL90N 90L Inside open -66LL90N 90L Inside open -88LL90N 90L Inside open -22LL90 90L Top Open -44LL90 90L Top Open -66LL90 90L Top Open -88LL90 90 Elbow -22LL45T 45L Outside open -44LL45T 45L Outside open -66LL45T 45L Outside open -88LL45T 45L Outside open -22LL45N 45L Inside open -44LL45N 45L Inside open -66LL45N 45L Inside open -88LL45N 45L Inside open -22LL45 45L Top Open -44LL45 45L Top Open -66LL45 45L Top Open -88LL45 45 Elbow -22LTT Tee Top open -44LTT Tee Top open -66LTT Tee Top open -88LTT Tee Top open -22LT Tee Outside open -44LT Tee Outside open -66LT Tee Outside open -88LT Tee Outside open -22LX Cross -44LX Cross -66LX Cross -88LX Cross -22LL90R Clockwise Transposition -44LL90R Clockwise Transposition -66LL90R Clockwise Transposition -88LL90R Clockwise Transposition 90L 90L 90L 90L -22LL90L Counter Clockwise -44LL90L Counter Clockwise -66LL90L Counter Clockwise -88LL90L Counter Clockwise Transposition 90L Transposition 90L Transposition 90L Transposition 90L -22LCS Straight Clockwise -44LCS Straight Clockwise -66LCS Straight Clockwise -88LCS Straight Clockwise Transposition Transposition Transposition Transposition -22LCC Straight Counter -44LCC Straight Counter -66LCC Straight Counter -88LCC Straight Counter Clockwise Transposition Clockwise Transposition Clockwise Transposition Clockwise Transposition -22LJ Junction ox -44LJ Junction ox -66LJ Junction ox -88LJ Junction ox -22LTS Telescope -44LTS Telescope -66LTS Telescope -88LTS Telescope -22LF ox Fitting -44LF ox Fitting -66LF ox Fitting -88LF ox Fitting -22LCF Cut-off Fitting -44LCF Cut-off Fitting -66LCF Cut-off Fitting -88LCF Cut-off Fitting -22LN1 Nipple 1" -44LN1 Nipple 1" -66LN1 Nipple 1" -88LN1 Nipple 1" -22LN2 Nipple 2" -44LN2 Nipple 2" -66LN2 Nipple 2" -88LN2 Nipple 2" -22LN3 Nipple 3" -44LN3 Nipple 3" -66LN3 Nipple 3" -88LN3 Nipple 3" N Reducer -42LR Reducer -64LR Reducer -86LR Reducer -22LH racket Hanger -44LH racket Hanger -66LH racket Hanger -88LH racket Hanger -22LDH Drop Hanger -44LDH Drop Hanger -66LDH Drop Hanger -88LDH Drop Hanger -22LEP End Plate -44LEP End Plate -66LEP End Plate -88LEP End Plate -22LFP Flat Sealing Plate -44LFP Flat Sealing Plate -66LFP Flat Sealing Plate -88LFP Flat Sealing Plate -22LNP 90 Sealing Plate -44LNP 90 Sealing Plate -66LNP 90 Sealing Plate -88LNP 90 Sealing Plate Wireways & Trough Products 155
156 JIC LY-IN WIREWY FITTINGS D C TEE TOP OPENING This is used when all the wireway branches open on the same side D Wireways & Trough Products C C STRIGHT TRNSPOSITION CLOCKWISE TEE OUTSIDE OPENING This is used when two branches open on the same side and the third opens on another side C STRIGHT TRNSPOSITION COUNTER CLOCKWISE
157 JIC LY-IN WIREWY FITTINGS C C C Wireways & Trough Products 90 ELOW TOP OPENING E 90 ELOW INSIDE OPENING 90 ELOW OUTSIDE OPENING E E 45 ELOW TOP OPENING 45 ELOW OUTSIDE OPENING 45 ELOW INSIDE OPENING 157
158 JIC LY-IN WIREWY FITTINGS M K R S T DROP HNGER llows a run of wireway to be suspended from the ceiling RCKET HNGER llows a run of wireway to be attached to the wall, ceiling, or floor Wireways & Trough Products END PLTE Used to close off the end of a wireway run REDUCER Reduces the run to a smaller wireway size without losing the lay-in feature. Furnished with special sealing plate C TELESCOPE llows easy adjustment for up to 12" L NIPPLE vailable in 1", 2", 3", and 6" lengths
159 JIC LY-IN WIREWY FITTINGS Wireway Size C D E F G K M R S T X Y Z 2 1/2x2 1/2 2 1/2 2 1/2 6 1/2 10 1/2 3 3/8 N N 11 3/4 4 5/ / /2 12 4x /2 2 1/2 13 1/4 6 1/8 5 1/2 5 1/ x /8 4, 2 1/2 4, 2 1/2 15 1/4 8 1/8 7 1/2 5 1/ x /8 6,4,2 1/2 6,4,2 1/2 19 1/4 10 1/8 9 1/2 5 1/ C C COUNTER CLOCKWISE TRNSPOSITION 90 ELOW CLOCKWISE TRNSPOSITION 90 ELOW Z X Y CUT-OFF FITTING For lengths of 8" to 20". The body comes in two pieces. Shorten body and cover to desired length and weld Wireways & Trough Products JUNCTION OX JIC LTCH ON LL FOUR CORNERS D D CROSS n intersection device used when all wireway opens on the same side 159
160 NEM 1 X-RY EQUIPMENT LY-IN DUCT ustin Lay-In wireway for X-Ray equipment is Underwriters Laboratories Listed and is designed to house electrical wiring where protection from dust, dirt, oil, and water are not necessary. Construction: Fabricated in accordance with UL specifications from code gauge steel. Single sheet steel for body. Cover attached to body with plated steel screws. Finish: Wireways & Trough Products SCREW QUNTITY & LOCTION VRY WITH LENGTH ustin Lay-In wireway for X-Ray equipment is provided standard with an NSI 61 gray polyester powder coating inside and out. C Options: Special materials. Special finishes. INDUSTRY STNDRDS UL 870 NEM Type 1 CUL 870
161 NEM 1 X-RY EQUIPMENT LY-IN DUCT Catalog Wireway Weight Catalog Wireway Weight Number Size (xxc) Number Size (xxc) -1012YW 10x3 1/2x YW 18x3 1/2x YW 10x3 1/2x YW 18x3 1/2x YW 10x3 1/2x YW 18x3 1/2x YW 10x3 1/2x YW 18x3 1/2x YW 10x3 1/2x YW 18x3 1/2x YW 10x3 1/2x YW 18x3 1/2x YW 10x3 1/2x YW 18x3 1/2x YW 10x3 1/2x YW 18x3 1/2x YW 10x3 1/2x YW 18x3 1/2x Catalog Description Weight Catalog Description Weight Number Number -60YD 60" Divider 5-60YD 60" Divider 5-10YHL Horizontal 90 Elbow 8-18YHL Horizontal 90 Elbow 23-10YVL Vertical 90 Elbow 7-18YVL Vertical 90 Elbow 11-10YHT Horizontal Tee 7-18YHT Horizontal Tee 23-10YVT Vertical Tee 7-18YVT Vertical Tee 23-10YX Cross 8-18YX Cross 24-10YEC End Cap 1-18YEC End Cap 2-10YC U-Connector 1-18YC U-Connector 2-10YP Panel dapter 2-18YP Panel dapter 2 Wireways & Trough Products 161
162 NEM 1 X-RY DUCT EQUIPMENT FITTINGS END CP D CROSS C D C Wireways & Trough Products HORIZONTL 90 ELOW E HORIZONTL TEE F E VERTICL 90 ELOW VERTICL TEE Wireway Size C D E F 10x3 1/ / /2 18x3 1/ / /2
163 NEM 1 X-RY DUCT EQUIPMENT FITTINGS Wireways & Trough Products CONNECTOR TYPICL X-RY DUCT RUN DIVIDER PNEL DPTER 163
164 JIC PNELS STEEL, LUMINUM, STINLESS JIC steel panels are 14 gauge painted white. Stainless steel panels are 14 gauge Type 304. luminum panels are 5052-H32 aluminum alloy. Mounting hardware is furnished with all enclosures that will accept these panels. Catalog Panel Weight Number Size (Steel) (x) -64JP 4 7/8 x 2 7/ JP 4 7/8 x 4 7/ JP 6 7/8 x 4 7/8 1-88JP 6 7/8 x 6 7/ JP 8 7/8 x 6 7/ JP 8 7/8 x 8 7/ JP 10 7/8 x 4 7/ JP 10 7/8 x 8 7/ JP 10 7/8 x 10 7/ JP 12 7/8 x 10 7/ JP 14 7/8 x 12 7/8 5 ccessories.218 x.312 OROUND.31.31
165 JIC PNELS STEEL, LUMINUM, STINLESS Catalog Panel Weight Number Size (luminum) (x) -64JP 4 7/8 x 2 7/ JP 4 7/8 x 4 7/ JP 6 7/8 x 4 7/ JP 8 7/8 x 6 7/ JP 10 7/8 x 8 7/ JP 12 7/8 x 10 7/ JP 14 7/8 x 12 7/8 2 Catalog Panel Weight Number Size (Stainless Steel) (x) -66JPX 4 7/8 x 4 7/ JPX 6 7/8 x 4 7/8 1-88JPX 6 7/8 x 6 7/ JPX 8 7/8 x 6 7/ JPX 10 7/8 x 8 7/ JPX 10 7/8 x 10 7/ JPX 12 7/8 x 10 7/ JPX 14 7/8 x 12 7/8 5 ccessories 165
166 NEM STEEL PNELS FOR SINGLE ND DOULE DOOR NEM Panels are code gauge steel and painted white. ll panels have flanges on all four sides. Stainless steel panels are Type 304 or optional 316 stainless steel. Panel mounting hardware is furnished with all enclosures that will accept these panels. ccessories OMIT TWO MIDDLE HOLES IF PNEL WIDTH IS 27" OR UNDER OMIT TWO MIDDLE HOLES IF PNEL HEIGHT IS 27" OR UNDER
167 NEM STEEL PNELS FOR SINGLE ND DOULE DOOR Steel Panels for Single Door NEM 4 & 12 and Double Door Wall-Mt N-12 Catalog Stainless Steel Panel Size Weight Catalog Stainless Steel Panel Size Weight Number Catalog Number (x) Number Catalog Number (x) -1612TP -1612TPX 13x TP -3630TPX 33x TP -1616TPX 13x TP -3636TPX 33x TP -2012TPX 17x TP -4224TPX 39x TP -2016TPX 17x TP -4230TPX 39x TP -2020TPX 17x TP -4236TPX 39x TP -2412TPX 21x TP -4824TPX 45x TP -2416TPX 21x TP -4830TPX 45x TP -2418TPX 23x TP -4836TPX 45x TP -2420TPX 21x TP -6030TPX 57x TP -2424TPX 21x TP -6036TPX 57x TP -3016TPX 27x TP -6042TPX 57x TP -3020TPX 27x TP -7224TPX 69x TP -3024TPX 27x TP -7230TPX 69x TP -3030TPX 27x TP -4848TPX 45x TP -3624TPX 33x21 24 Steel Panels for Double Door NEM 12 with Legs Catalog Panel Size Weight Catalog Panel Size Weight Number (x) Number (x) -5442DP 50x DP 68x DP 56x DP 68x DP 56x Steel Panels for Freestanding NEM 12 Catalog Panel Size Weight Catalog Panel Size Weight Number (x) Number (x) -7224FTP 60x FTP 60x FTP 60x FTP 60x FTP 60x FTP 60x FTP 78x FTP 78x ccessories Steel Panels for Double Door NEM 4 Catalog Panel Size Weight Catalog Panel Size Weight Number (x) Number (x) -6248FP 56x FP 68x FP 56x FP 68x
168 JIC SWING-OUT PNEL KITS Designed to allow mounting of switches, gauges, pilot lights, and other components near the front of enclosure for easy access. Each kit contains heavy-gauge brackets and hinges which can be installed by drilling holes in the sides of the enclosure and bolting the brackets in place. Mounting hardware and instructions are provided. Swing-out panels can be mounted on either side. Sealing washers are furnished to ensure that the enclosures will meet the original JIC standards after they are installed. JIC box Swing-Out Panel Kit can be mounted in the following enclosures: ll JIC boxes where x is 8 x 6 or larger. ccessories Catalog Number -JSOPK Description JIC Swing-Out Panel Kit *Panels must be ordered separately. *The maximum load on JIC Panel Kit cannot exceed 25 pounds. The load includes the weight of the panel plus the weight of the added components, with the weight of the components spread evenly over the panel.
169 JIC SWING-OUT PNEL KITS MIN DETIL "" DETIL "" DETIL "" HINGE RCKETS RETINING RCKETS SELING WSHERS ENCLOSURE (ORDER SEPRTELY) PNEL (ORDER SEPRTELY) RCKET MOUNTING SCREWS PNEL MOUNTING SCREWS ccessories DETIL "" SCREW RETINER SPCE VILLE ON SWING-OUT PNEL CPTIVE THUM SCREW 169
170 NEM SWING-OUT PNEL KITS Designed to allow mounting of switches, gauges, pilot lights, and other components near the front of enclosure for easy access. Each kit contains heavy-gauge brackets and hinges which can be installed by drilling holes in the sides of the enclosure and bolting the brackets in place. Mounting hardware and instructions are provided. Swing-out panels can be mounted on either side. Sealing washers are furnished to ensure that the enclosures will meet the original NEM standards after they are installed. NEM Swing-Out Panel Kit can be mounted in the following enclosures: ll single door Type 4, 12, and 13 enclosures where x is 12 x 12 or larger. ll WL Type 3R enclosures where x is 16 x 16 or larger. ll LM Type 1 enclosures where x is 16 x 12 or larger. ccessories Catalog Number -NSOPK Description NEM Swing-Out Panel Kit *Panels must be ordered separately. *The maximum load on NEM Panel Kit cannot exceed 100 pounds. The load includes the weight of the panel plus the weight of the added components, with the weight of the components spread evenly over the panel.
171 NEM SWING-OUT PNEL KITS MIN DETIL "" DETIL "" DETIL "" RCKET MOUNTING SCREW HINGE RCKET ENCLOSURE (ORDER SEPRTELY) SELING WSHER RETINING RCKET PNEL (ORDER SEPRTELY) PNEL MOUNTING CRRIGE OLT ccessories CPTIVE THUM SCREW SPCE VILLE ON SWING-OUT PNEL SCREW RETINER DETIL "" 171
172 JIC TERMINL STRP KIT SSEMLY Provides a strong, versatile, and easily installed means for mounting terminal blocks in JIC boxes. These kits can be installed in all JIC boxes. racket ssembly: Each bracket assembly consists of two brackets which mount on panel stand-offs in the box. Finish is white. Terminal Strap: TERMINL STRP X RCKET F G gauge flat strap that mounts on top of brackets. They can be positioned anywhere along the brackets and are held in place with spring locking nuts. Finish is white ccessories X E SECTION X-X Terminal Kit ssembly for JIC oxes racket ssemblies racket ssembly Enclosure Dimension "E" Catalog Number Parallel to rackets Dimension -6JKT 6 5-8JKT JKT JKT JKT Terminal Strap Enclosure Dimension "F" "G" Catalog Number Parallel to Straps Dimension Dimension (Useable Space) -8JTST JTST JTST JTST JTST
173 NEM TERMINL STRP KIT SSEMLY Provides a strong, versatile, and easily installed means for mounting terminal block supports. These kits fit Type 4, 12, and 13 enclosures as well as Large Type 1 enclosures. racket ssembly: Each bracket assembly consists of two or three brackets which mount on panel stand-offs in the box. Finish is white. Terminal Strap: RCKET 12 gauge flat channel strap that mounts on top of brackets. They can be positioned anywhere along the brackets and are held in place with spring locking nuts. Finish is white. X 1.50 F E X D TERMINL STRP SECTION X-X ccessories Terminal Kit ssembly for NEM racket ssemblies racket ssembly Number of Enclosure Dimension "D" Catalog Number rackets Parallel to rackets Dimension -12NKT NKT NKT NKT NKT NKT NKT NKT NKT Terminal Strap Enclosure Dimension "F" "E" Catalog Number Parallel to Straps Dimension Dimension (Useable Space) -16NTS NTS NTS NTS NTS NTS NTS NTS
174 USTIN LOUVER PLTE KITS ustin Louver Plate Kits are designed to provide ventilation for areas where excessive moisture or internal heat is present. They are easily installed by making a cutout of the proper size and attaching the louver plate to the enclosure. ll hardware is furnished for mounting. Catalog Louver Number of Size of Weight Number Length Louvers Plate -44LK 4" 4 5 5/8" x 5 1/2" 1-58LK 5" 8 7 1/4" x 10 3/4" 1 ccessories LOUVER PLTE CINET 1/4-20 HEX NUT 1/2 X 1/4" WSHER 3/16" GSKET MTERIL 1/4-20 X 3/4" HEX HED CP SCREW
175 USTIN WINDOW KITS ustin Window Kits are easily installed by making a cutout in the enclosure and attaching the window and frame in place. Frames are fabricated from 14 gauge steel with an NSI 61 gray polyester powder coating or 14 gauge Type 304 stainless steel. The window is.25 clear acrylic plastic for both kits. neoprene gasket around the frame preserves the watertight rating. ll mounting hardware and installation instructions are furnished. Catalog S.S. Catalog Window Size Frame Size Cut-Out Size Weight Number Number ExF x CxD -53WK -53WKX 5x3 7.5x x WK -95WKX 9x x x WK -133WKX 13x3 15.5x x WK -138WKX 13x8 15.5x x WK -175WKX 17x x x WK -1711WKX 17x x x WK -2315WKX 23x x x WK -2919WKX 29x x x WK -3523WKX 35x x x ccessories 175
176 USTIN MOUNTING FOOT KITS ustin Mounting Foot Kits contain four 14 gauge steel with an NSI 61 gray polyester powder coating, galvanized, or Type 304 stainless steel external mounting feet and fasteners. Sealing washers are provided with each kit to maintain Type 4, 4X or Type 12 rating after field installation. Catalog Number -MTGFT-GL -MTGFT-GRY -MTGFT-SS Description Galvanized Mounting Foot Kit Steel Mounting Foot Kit - Painted Gray Stainless Steel Mounting Foot Kit ccessories
177 USTIN DOOR STOP KITS Door Stop Kits are designed for securing the door of the enclosure in the open position. Kits can be mounted at the top or bottom of the door opening. Two holes must be drilled in the enclosure and in the door. The angle of the door is adjusted by a wingnut and the stop arm slides out of the way when the door is closed. must have a dimension of 16 or more and the door must open horizontally. ccessories Catalog Number -DSTOPK -DSTOPKX Description Plated Steel Door Stop Kit Stainless Steel Door Stop Kit 177
178 USTIN FLOOR STND KITS ustin Floor Stand Kits can be installed easily on ustin NEM 4, 4X, and 12 single and double door enclosures. To install Floor Stand Kits, drill holes in bottom of enclosure and bolt on. Each kit includes two stands and is fabricated from 10 gauge steel with an NSI 61 gray polyester powder coating or 12 gauge Type 304 stainless steel. Catalog Stainless Steel Floor Stand Depth of Enclosure Weight Number Catalog Number Height "C" Dimension -6SK8-6SK8SS SK10-6SK10SS SK12-6SK12SS SK8-12SK8SS SK10-12SK10SS SK12-12SK12SS SK16-12SK16SS SK20-12SK20SS SK8-18SK8SS SK10-18SK10SS SK12-18SK12SS SK16-18SK16SS SK8-24SK8SS SK10-24SK10SS SK12-24SK12SS SK16-24SK16SS ccessories
179 USTIN OILTIGHT HOLE SELS Knockouts, pushbutton holes, and conduit openings can be sealed against dust, dirt, oil, and water with ustin Hole Seals. Hole Seals are fabricated from 14 gauge steel with an NSI 61 gray polyester powder coating or from 14 gauge Type 304 stainless steel. ll Hole Seals are constructed with a neoprene oil resistant gasket, stainless steel stud and stainless steel wing nut. Catalog Stainless Steel Description Hole Seal Number Catalog Number Diameter ccessories 050HS 050HSSS 1/2" - conduit HS 075HSSS 3/4" conduit HS 100HSSS 1" conduit HS 125HSSS 1 1/4" conduit HS 150HSSS 1 1/2" conduit HS 200HSSS 2" conduit HS 250HSSS 2 1/2" conduit HS 300HSSS 3" conduit HS 350HSSS 3 1/2" conduit HS 400HSS 4" conduit MHS MHSSS 22.5mm pushbutton holes PHS PHSSS 30.5mm pushbutton holes
180 USTIN DRIPSHIELD KITS ustin Dripshield Kits protect from dripping water and settling dust. Easily installed to enclosure with carriage bolts and sealing washers (hardware is furnished). Dripshield kits are fabricated from 12 gauge steel and provided standard with an NSI 61 gray polyester powder coating or fabricated from Type gauge stainless steel. (Stainless hardware is furnished). Catalog S.S. Catalog Enclosure Width Weight Number Number "" Dimension -12DK -12DKX DK -16DKX DK -20DKX DK -24DKX DK -30DKX DK -36DKX DK -42DKX DK -48DKX DK -60DKX DK -72DKX 72 6 ccessories DRIPSHIELD ENCLOSURE DOOR DRIPSHIELD ENCLOSURE 12" MX. 1/4-20x3/4 CRRIGE OLT DOOR FCTORY INSTLLED DRIPSHIELD WELDED ON ENCLOSURE DRIPSHIELD FOR N-12 & N-4 (EXCEPT FS) INVERT DRIPSHIELD S SHOWN FOR FREESTNDING N-12 ND N-4 ONLY 1/4 RUER FLT WSHER 1/4 RUER FENDER WSHER 1/4-20 LOCKNUT
181 USTIN PRINT POCKETS ustin print pockets provide a convenient place to store charts, wiring diagrams, and other documentation in the enclosure. Self-adhesive backs make for easy installation on the inside of enclosure door. Thermoplastic pockets are provided standard light gray. Catalog Description Inside Dimensions Number xxc -SMPRPKT Small Print Pocket 5 7/8 x 5 7/8 x 1 -LGPRPKT Large Print Pocket 9 1/8 x 8 5/8 x 1 3/16 C ccessories 181
182 USTIN LOCKS, LTCHES ND SSEMLIES Tee Handles Catalog Number Description Tee handle with lock Tee handle Standard Lever Handles Locks & Latches Catalog Number -6-7 Description Lever handle Lever handle with lock
183 USTIN LOCKS, LTCHES ND SSEMLIES Padlockable Lever Handle Catalog Number -18 Description Stainless Steel padlockable lever handle Locks nd Latches Catalog Number X Description Flush cylinder lock Quarter-turn latch NEM-4 Quarter-turn latch NEM-4 Stainless Steel Quarter-turn latch Locks & Latches 183
184 USTIN LOCKS, LTCHES ND SSEMLIES JIC Quick Release Latch Catalog Number Description JIC Draw Pull Latches Catalog Number Description X Plated Steel JIC Quick Release Latch Stainless Steel JIC Quick Release Latch X JIC Quick release catch for field installation JIC Quick release catch stainless steel for field installation Locks & Latches Draw Pull Latch Locking Flush Latch Catalog Number Description Catalog Number Description -1-1X Draw pull catch with hasp Stainless Steel Draw pull catch with hasp -16 Flush lift-latch with lock
185 USTIN LOCKS, LTCHES ND SSEMLIES JIC Clamp ssembly Hasp and Staple Catalog Number Description Catalog Number Description -CLMPSET-JIC JIC Clamp ssembly -3 Hasp and Staple Locks & Latches Quick Release NEM NEM Latch Latch NEM Clamp ssembly Catalog Number Description Catalog Number Description -20SM -20 Quick release NEM clamp assembly Quick release NEM clamp Toggle Latch -CLMPSET-NEM NEM Clamp ssembly 185
186 INDEX ustin products are listed in catalog by a catalog number consisting of the following alpha codes: (ir Conditioners, Heat Exchangers, Fans and Packaged lowers are listed on the last page of index) Examples: 1. - ustin ox H x W x D 3. CODE - Product CODE -664S - 6 x 6 x 4 Screw Cover ox Galvanized HW - 10 x 10 x 120 Hinge Cover Wireway Galvanized The following is a list of product codes and page location: Index Product Code Product Code Description Description Page Number Page Number D Extra Deep Pushbutton Enclosure 114,115 D Extra Deep Pushbutton lank Cover Enclosure 114,115 F NEM 4X Pushbutton Enclosure 120,121 M Slim-Line Pushbutton Enclosure 118,119 N Standard Pushbutton Enclosure 112,113 N Standard Pushbutton lank Cover Enclosure 112,113 P Pendant Pushbutton Enclosure 116,117 S Sloping Pushbutton Enclosure 124,125 -X (Ex. -7) Locks & Latches X Extra Large Hinge Cover Pushbutton Enclosure with ack Panel 122,123 ase DK Dripshield Kit 180 DKX Stainless Steel Dripshield Kit 180 DP Double Door NEM 12 Panel 166,167 DSTOPK Door Stop Kit 177 DSTOPKX Stainless Steel Door Stop Kit 177 EP NEM 1 End Plate 146,147 EPG NEM 1 End Plate Gray 146,147 FN Flush NEM 12 Enclosure 38,39 FP Double Door NEM 4 Panel 166,167 FSN NEM 12 Freestanding Single Door Enclosure 42,43 FSN/DSC NEM 12 Freestanding Single Door Disconnect Enclosure 72-75,80-89 FSND NEM 12 Freestanding Double Door Enclosure 44,45 FSND/DSC NEM 12 Freestanding Double Door Disconnect Enclosure FTP Freestanding NEM 12 Panel 166,167 GS Gasket Screw Cover ox Galvanized 6,7 GSG Gasket Screw Cover ox Gray 6,7 GST Gasket Screw Trough Galvanized 134,135 GSTG Gasket Screw Trough Gray 134,135 HC Hinge Cover ox Galvanized 4,5 HCG Hinge Cover ox Gray 4,5 HCGK Hinge Cover ox Gray with Knockouts 4,5 HCK Hinge Cover ox with Knockouts 4,5 HS Hole Seal 179
187 INDEX Product Code Description Page Number HSSS Stainless Steel Hole Seal 179 HT Hinge Cover Trough Galvanized 132,133 HTG Hinge Cover Trough Gray 132,133 HW Hinge Cover Wireway Galvanized 144,145 HWG Hinge Cover Wireway Gray 144,145 HWGK Hinge Cover Wireway Gray with Knockouts 144,145 HWK Hinge Cover Wireway with Knockouts 144,145 JF JIC Pull-Through ox Fitting 150,151 JFX JIC Pull-Through Stainless Steel ox Fitting 150,151 JH JIC Pull-Through racket Hanger 150,151 JHX JIC Pull-Through Stainless Steel racket Hanger 150,151 JKT JIC racket ssembly 172 JC JIC Clamp Cover luminum NEM 4X ox 106,107 JCF JIC Pull-Through Cut-Off Fitting 150,151 JCFX JIC Pull-Through Stainless Steel Cut-Off Fitting 150,151 JDH JIC Pull-Through Drop Hanger 150,151 JDHX JIC Pull-Through Stainless Steel Drop Hanger 150,151 JEP JIC End Plate 150,151 JEPX JIC End Plate Stainless Steel 150,151 JFC JIC Clamp Cover NEM 4 ox 98,99 JFCX JIC Clamp Cover NEM 4X Stainless Steel ox 102,103 JFH JIC Continuous Hinge NEM 4 ox 96,97 JG JIC Gasket 150,151,153,155 JH JIC Continuous Hinge ox 90,91 JH JIC Continuous Hinge luminum ox 104,105 JHFX JIC Continuous Hinge NEM 4X Stainless Steel ox 100,101 JL JIC Lift-Off ox 92,93 JL45 JIC Pull-Through 45 Elbow 150,151 JL45X JIC Pull-Through Stainless Steel 45 Elbow 150,151 JL90 JIC Pull-Through 90 Elbow 150,151 JL90X JIC Pull-Through Stainless Steel 90 Elbow 150,151 JN1 JIC Pull-Through 1" Nipple 150,151 JN1X JIC Pull-Through Stainless Steel 1" Nipple 150,151 JN2 JIC Pull-Through 2" Nipple 150,151 JN2X JIC Pull-Through Stainless Steel 2" Nipple 150,151 JN3 JIC Pull-Through 3" Nipple 150,151 JN3X JIC Pull-Through Stainless Steel 3" Nipple 150,151 JP JIC Panel 164,165 JP JIC luminum Panel 164,165 JPX JIC Stainless Steel Panel 164,165 JR JIC Pull-Through Reducer 150,151 JRX JIC Pull-Through Stainless Steel Reducer 150,151 JS JIC Screw Cover ox 94,95 JSOPK JIC Swing-Out Panel Kit 168,169 JTE JIC Pull-Through Tee 150,151 JTEX JIC Pull-Through Stainless Steel Tee 150,151 JTR JIC Hinge Cover Trough 140,141 JTS JIC Pull-Through Telescope 150,151 JTS JIC Screw Cover Trough 138,139 JTS JIC Terminal Strap 172 JTSX JIC Pull-Through Stainless Steel Telescope 150,151 JW JIC Pull-Through Wireway 148,149 JWFX JIC Pull-Through Wireway Nema 4X 152,153 JX JIC Pull-Through Cross 150,151 JXL Large Oiltight Enclosure 110,111 Index 187
188 INDEX Product Code Description Page Number Index JXX JIC Pull-Through Stainless Steel Cross 150,151 L45 NEM 1 45 Elbow 146,147 L45G NEM 1 45 Elbow Gray 146,147 L90 NEM 1 90 Elbow 146,147 L90G NEM 1 90 Elbow Gray 146,147 LF JIC Lay-In ox Fitting 158,159 LH JIC Lay-In racket Hanger 158,159 LCC JIC Lay-In Straight Counter Clockwise Transposition 156,157 LCF JIC Lay-In Cut-Off Fitting 158,159 LCS JIC Lay-In Straight Clockwise Transposition 156,157 LDH JIC Lay-In Drop Hanger 158,159 LEP JIC End Plate 158,159 LFP JIC Lay-In Flat Sealing Plate 158,159 LJ JIC Lay-In Junction ox 158,159 LK Louver Kit 174 LL45 JIC Lay-In Top Open 45 Elbow 156,157 LL45N JIC Lay-In Inside Open 45 Elbow 156,157 LL45T JIC Lay-In Outside Open 45 Elbow 156,157 LL90 JIC Lay-In Top Open 90 Elbow 156,157 LL90L JIC Lay-In Counter Clockwise Transposition 90 Elbow 156,157 LL90N JIC Lay-In Inside Open 90 Elbow 156,157 LL90R JIC Lay-In Clockwise Transposition 90 Elbow 158,159 LL90T JIC Lay-In Outside Open 90 Elbow 158,159 LM Large O.E.M. ox 12,13 LN1 JIC Lay-In 1" Nipple 158,159 LN2 JIC Lay-In 2" Nipple 158,159 LN3 JIC Lay-In 3" Nipple 158,159 LNP JIC Lay-In 90 Sealing Plate 158,159 LR JIC Lay-In Reducer 158,159 LT JIC Lay-In Tee Outside Open 156,157 LTS JIC Lay-In Telescope 158,159 LTT JIC Lay-In Tee Top Open 156,157 LW JIC Lay-In Wireway 154,155 LX JIC Lay-In Cross 158,159 MTGFT Mounting Foot Kit 176 N NEM 12 Enclosure N/DSC NEM 12 llen-radley Disconnect Enclosure N/DSC NEM 12 Disconnect Enclosure 48-51, N NEM 12 luminum Enclosure 40,41 NKT NEM racket ssembly 173 ND NEM 12 Double Door Enclosure 36,37 ND/FDSC NEM 12 Double Door Disconnect Enclosure 68-71, NF NEM 4 Enclosure 24,25 NF/DSC NEM 4 Disconnect Enclosure NF NEM 4X luminum Enclosure 30,31 NFD NEM 4 Double Door Enclosure 26,27 NFX NEM 4X Stainless Steel Enclosure 28,29 NFX/DSC NEM 4X Stainless Steel Disconnect Enclosure NSOPK NEM Swing-Out Panel Kit 170,171 NTS NEM Terminal Strap 173 P NEM 1 Panel dapter 146,147 PC Oiltight Consolet
189 INDEX Product Code Description Page Number PRPKT Print Pocket 181 PS Pedestal R NEM 1 Reducer 146,147 R Rainproof ox Galvanized 8,9 RG Rainproof ox Gray 8,9 RG NEM 1 Reducer Gray 146,147 RT Rainproof Trough Galvanized 136,137 RTG Rainproof Trough Gray 136,137 S Screw Cover ox Galvanized 2,3 SG Screw Cover ox Gray 2,3 SGK Screw Cover ox Gray with Knockouts 2,3 SK Screw Cover ox with Knockouts 2,3 SK Floor Stand Kit 178 SKX Stainless Steel Floor Stand Kit 178 SL Style-Line Enclosure SLX Style-Line Enclosure Stainless Steel SM Small O.E.M. ox 10,11 ST Screw Trough Galvanized 130,131 STE Small Oiltight Enclosure 108,109 STG Screw Trough Gray 130,131 SW Screw Cover Wireway Galvanized 142,143 SWG Screw Cover Wireway Gray 142,143 SWGK Screw Cover Wireway Gray with Knockouts 142,143 SWK Screw Cover Wireway with Knockouts 142,143 T Telephone Cabinet 14,15 TE NEM 1 Tee 146,147 TEG NEM 1 Tee Gray 146,147 TL Telephone Cabinet Flush 14,15 TP NEM Panel 166,167 TPX Stainless Steel NEM Panel 166,167 TS NEM 1 Telescope 146,147 TSG NEM 1 Telescope Gray 146,147 UC NEM 1 U-Connector 146,147 UCG NEM 1 U-Connector Gray 146,147 UH NEM 1 U-Hanger 146,147 UHG NEM 1 U-Hanger Gray 146,147 WDN NEM 12 Double Door Wall-Mount Enclosure 46,47 WK Window Kit 175 WKX Stainless Steel Window Kit 175 WL Large Weatherproof Cabinet 18,19 WS Small Weatherproof Cabinet 16,17 X NEM 1 Cross 146,147 XG NEM 1 Cross Gray 146,147 YC U-Connector (X-Ray) 162,163 YD 60" Divider (X-Ray) 162,163 YEC End Cap (X-Ray) 162,163 YHL Horizontal 90 Elbow (X-Ray) 162,163 YHT Horizontal Tee (X-Ray) 162,163 YP Panel dapter (X-Ray) 162,163 YVL Vertical 90 Elbow (X-Ray) 162,163 YVT Vertical Tee (X-Ray) 162,163 YW Lay-In Duct for X-Ray Equipment 160,161 YX Cross (X-Ray) 162,163 Index 189
190 NOTES
191 NOTES
192 NOTES
JIC CONTINUOUS HINGE BOXES
JIC CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing.
Type 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
Section H Index. www.hubbell-wiegmann.com Data Subject To Change Without Notice OPERATOR INTERFACE
Section H Index H1 W1 Series NEMA 12 onsoles...h2 W9 Series NEMA 12 onsoles...h4 W10 Series NEMA 12 onsoles...h6 W12 Series NEMA 12 onsoles...h8 W14 Series NEMA 12 onsoles...h10 W- Series NEMA 12 onsolets...h12
Cable & Wire Management
able & ire Management able & ire Management Lay-In ireway Type 1 Screw over... 8-14 Lay-In ireway Type 1 Quick-onnect inge over... 15-20 Lay-In ireway Type 3R EnviroShield... 21-24 Lay-In ireway Type 12...
www.hammondmfg.com General Accessories Hardware
Heavy Duty Door Clamping Junction Box Padlock Kit Quick Release Clamp Replacement hardware for use on all 1418 and 1447 Series enclosures. Formed heavy gauge stainless steel clamp with stainless steel
FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.
FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds
Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Catalog Number. Type 1 Enclosure Flush Lock. New Flush lock
Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Type 1 Panel Enclosure Flush Lock Type 1 Enclosure Flush Lock T1EFL New Flush lock.886 dia. (22) Hole Pattern Detail Flush Locks are
Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11
Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU
CABINET OPTIONS AND DESIGNATORS
CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
Scepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.
ARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors
Drawing Board Storage, Open Drawing Board Storage, Doors Drawing Board Storage Notebook Storage, Open 1670 D : 23.25" holds 32 drawing boards 1 shelf, adjustable on 1¼" increments maximum board height
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
Premier & Deluxe 3-Season Room Sliding Glass Door
DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen
Catalog Number L (in.) L (mm) ACLJIC 1.25 32. Catalog Number ACLSN12 1.69 43 APLKJIC APLKJIC6SS
Spec-00479 G763.422.2211 763.422.2600 Locks, Lockouts, Latches, Handles and Clamps Locks Locks, Lockouts, Latches, Handles and Clamps Locks Lock Kit for Clamp Cover Junction Boxes L (in.) L (mm) ACLJIC
GUE, GUB Junction Boxes
E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
ELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
FAIRFIELD INDUSTRIES INC.
FAIRFIELD INDUSTRIES INC. v NEW PRICE SCHEDULE 4/1/201 SUPERSEDES 4/1/11 SPILL CONTAINMENT And STREET ACCESS MANHOLES for UNDERGROUND And ABOVEGROUND TANKS SPILL CONTAINMENT MANHOLES MONITOR WELL SERIES
Low Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
Cedar Cottage Doghouse Plans
Overlapping cedar shingles add an element of charm to this medium size doghouse. The walls, floor, and trim are constructed of solid cedar, making it naturally weather resistant and provides excellent
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
MCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
Learning Module 13: Panelboards and Switchboards. 101 Basic Series
Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and
Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)
1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8
GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction
GEH6290 g Cable Operator Mechanisms for E150, SE150, SF250, and SG600 Spectra RMS Circuit Breakers Type SCH1/1X, SCH2/2X Flange-Mounted Handle Assemblies, Cable Series SC3L SC10L and Type SC0M1A, SCOM1EF,
Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
DIY CABINET REFACING INSTALLATION GUIDE
DIY CABINET REFACING INSTALLATION GUIDE CABINET REFACING INSTALLATION Are you ready to reface your outdated cabinets? This guide will show you how to install your new Facelifters Cabinet Refacing Products
Stainless Steel Continuous Hinges
Stainless Steel Continuous Hinges Hager heavy duty continuous hinges offer proven reliability that can stand up to the daily rigors of high-traffic, high-impact areas. They re designed and engineered to
Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications
Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down
LYCOMING O-360. Engine Installation
Engine Installation SECTION 4 Carburetor Heat Box Carb. Heat Box, hole at the bottom is the hot air exit when carb heat is not used. SECTION 4 - Page 1 of 13 Push Pull cable P/N 05-14084 Qty = 1 Length=7ft.
TRUCK BOXES - UNDERBODY BOXES
TRUCK BOXES - UNDERBODY BOXES BLACK, STAINLESS STEEL T-HANDLE LATCH 14-gauge steel box, 12-gauge steel door (12-gauge steel box, 12-gauge steel door on 66" toolboxes). Recessed/beveled door. Rain channel
Table of Contents. I. Roof Scuttles
Table of Contents I. 1. Specification Guidelines 2. Bilco Quote/Order Checklist 3. Target Markets 4. Product Training 5. Benefits/Features 6. Scuttle Handrails Specification Guidelines Key Bilco features
AMERICAN GOTHIC PLAYHOUSE
AMERICAN GOTHIC PLAYHOUSE Project Plan #856 Sheet 1 of 5 Pick a spot and get started with the beautiful that your kids will love. The design of the playhouse includes 35 square feet of interior space plus
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION
SPRINGLOK SYSTEM PRODUCT DESCRIPTION FEATURES & BENEFITS Fry Reglet offers five flashing systems, each tailored for a particular type of substrate so you can get exactly what you need. SM Surface mounted
MDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
Rack installation instructions
Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:
Integral Kit Instructions
Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has
PROLINE Go l d Se r i e s. Desk Consoles and Accessories
Modular Enclosure Systems Application PROLINE Gold Series desk consoles are ergonomically designed for use in either a sitting or standing position. Single-access consoles have a front door and solid back.
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
Installation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
INSTLLTION INSTRUTIONS 24" (61.0 M) LTRI SINGL N OUL UILT-IN OVN Table of ontents UILT-IN OVN SFTY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements... 2 lectrical Requirements...
2. The Laboratory Fume Hood Specification Catalog Select the style and size hoods appropriate for your layout and laboratory use.
TABLE OF CONTENTS How to Specify... 3 Introduction to Fisher Hamilton Stainless Steel Laboratory Casework... 4 5 Stainless Steel Casework Options Menu... 6 Base Cabinets... 7 17 Sitting Height Cabinets...
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures
Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house
K17.12 Door closers K17. Doors 01.09.2013
K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - [email protected] - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor
Linkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
Application Guide Selection of Type Enclosures
Application Guide Selection of Type Enclosures. ASCO Power Technologies Enclosure Application Guide June 2009 Pub. 3212 1 Mission Statement The purpose of this document is to educate the reader with regard
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
DCF Optimized Rack System
Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that
HARDWARE STANLEY ARCHITECTURAL HARDWARE
HARDWARE STANLEY ARCHITECTURAL HARDWARE STANLEY ARCHITECTURAL HARDWARE TABLE OF CONTENTS Page Company history...2 Wardrobe pivots...3, 4 Cabinet hinges... Cabinet pulls..., 6 Cabinet knobs...6 Cabinet
Scepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
Switchboard system. NorLine 800
Switchboard system NorLine 800 NorLine 800 SWITCHBOARD SYSTEM 2 NorLine 800 Switchboard system Table of contents Subject Page Table of contents 2 Overview 2-3 NorLine 800 technical specifications 4 Structural
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
Sarasota Splash Back Prep and Shine Paint Restorer Inside Front Cover
Caution: Read entire label before using product. Do-It-Yourself PAINT RESTORER KIT Kit Contains: 1-16 oz. Water-based, Biodegradeable Liquid Prep 1-16 oz. Aerosol Shine Spray 1 - Spray Nozzle 2 - Scrub
Installation Instructions and Ordering Information
The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using
Plugs and Receptacles
Plugs and Receptacles Industrial Heavy Duty Interlocked Application and Selection Applications: Where extra protection is a requirement; interlocked units provide dead front receptacles; connection cannot
FLOORTEC R 680 B. Part List US-English. Model: FLOORTEC R 680 B
Model: Part List US-English Table of Contents General view 3 Rotomolded assembly 5 Chassis assembly 7 Drive assembly 9 Steering assembly 11 Control pedals assembly 13 Waste container assembly 15 Filter
FAIRFIELD INDUSTRIES INC.
FAIRFIELD INDUSTRIES INC. v NEW SCHEDULE 4/1/2011 SUPERSEDES 6/9/08 SPILL CONTAINMENT and STREET ACCESS MANHOLES for UNDERGROUND and ABOVEGROUND TANKS SPILL CONTAINMENT MANHOLES HEAVY DUTY STREET MANHOLES
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
Heavy Duty Safety Switches
Features 15 3 2 20 9 11 16 17 1 18 6 19 13 5 SAFETY 8 1 12 7 1. Quick-make, quick-break operating mechanism that ensures positive operation. 2. Visible blade, double-break switching action. 3. Arc chutes
Series 18 Pass Thru Air Lock Cleanroom Entry System
OPERATION & MAINTENANCE INSTRUCTIONS FOR Series 18 Pass Thru Air Lock Cleanroom Entry System SOLUTIONS BUILT TO YOUR SPECIFICATIONS 8605 Wyoming Ave. N. Minneapolis MN 55445 fax: 763.425.2004 e-mail: [email protected]
All-Season Sunroom Sliding Glass Door Installation Instructions
ASRESGD-08 All-Season Sunroom Sliding Glass Door Installation Instructions Panel Frame Door Frame Left Side Foam Insulator IE241 H Bar Assembly Door Frame Top Track Panel Frame Door Frame Right Side Stationary
BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
EMEA Specifier s Guide. Industrial Cabinets CHAPTER. Industrial Cabinets
PH FX (763) 422-2600 422-22a EMEA Specifier s Guide Industrial Cabinets CHAPTER Industrial Cabinets Chapter Contents Industrial Cabinets PROLINE Modular Enclosure Systems PROLINE Modular Enclosures Product
TONNEAU INSTALLATION GUIDE
TONNEAU INSTALLATION GUIDE Warranty, Care & Maintenance Model 4056 Toyota Tacoma Double Cab 5' Short Bed 2005-Current (With Multi-Track System) EASY AS 1-2-3! NORMAL INSTALLATION TIME 30 MINUTES For Warranty
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
How to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
How To Fit A Portman Door Leaf
Portman Sliding Door Gear Timber/Frames Doors Frameless Glass Doors Top track Portman top tracks are suitable for door leaves of up to 80kg as standard Material is 6063T6 aluminium alloy anodised to 15
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS
DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS TheRTAStore.com STEP 1: CLEAR A WORK SPACE Place your RTA cabinet panels on a smooth, scratch resistant surface in a large, open area. (Some people like to
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
MODEL HSR-007 Direct Drive Rolling Steel
MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HSR-007
STEEL-RITE II or III COMMERCIAL SECTIONAL DOOR Owner s Manual Supplement Model 52242 NOTICE TO USER
STEEL-RITE II or III COMMERCIAL SECTIONAL DOOR Owner s Manual Supplement Model 52242 NOTICE TO USER Thank you for purchasing the Steel-Rite II or III, model 52242 commercial sectional door from RITE-HITE
Section 10 Electric Switchboards: 0 Through 600 Volts
Section 10 Electric Switchboards: 0 Through 600 Volts 10.1. Scope This section provides specific dimensions and details for service and meter equipment that is assembled by the manufacturer in freestanding,
Surgelogic Surge Protective Device (SPD)
Surgelogic Surge Protective Device () EB, EM, and HW Series atalog 1310T0202R05/09 2009 lass 1310 OTETS Description............................................. Page Product Description...........................................2
Fire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
glass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
ASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from
STANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS
STANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for providing metal fabricated items like castings, gratings, hatchways, ladders,
SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment
AIR CONDITIONING PRODUCTS COMPANY
Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter
Springlok Flashing System
Springlok Flashing System Why Fry Reglet? Fry Reglet s comprehensive selection of moisture prevention products offer the ultimate in protection from the elements. Available nationwide in a variety of materials
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
Temperature Controlled Enclosures
7 Indoors or Outdoors - We ve Got You Covered! Temperature Controlled Enclosures Protect your electronics and control their environment! FC Series - NEMA 3R outdoor enclosures with UL Listed fans, filters,
CNC Tool Storage Solutions
Solutions CNC TOOL STORAGE SOLUTIONS Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
