1 Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination Louve tainless Steel Shutter Ajustable Fixed Louver Volume Control Damper PVC Shutte all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination Lou r Stainless Steel Shutter Adjustable Fixed Louver Volume Control Damper PVC hutter Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Lou r Gable Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination ouver Stainless Steel Shutter Adjustable Fixed Louver Volume Control Damper PVC hutter Wall Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Wa hutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Gable hutter Drainable Louver Supply Damper Fiberglass Shutter Combination Louve tainless Steel Shutter Ajustable Fixed Louver Volume Control Damper PVC Shutte all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter Combination Lou r Stainless Steel Shutter Adjustable Fixed Louver Volume Control Damper PVC Manufacturer SHUTTERS DAMPERS LOUVERS Air Conditioning Products Company Ecorse Road, Romulus, Michigan Phone: Fax:
2 Table of Contents Louver Selection Guide Aluminum Fixed Louver, K-style blade Model AFL Galvaneal Steel Fixed Louver, K-style blade Model GFL Aluminum Adjustable Width Fixed Louver Model AAFL Galvanized Steel Adjustable Width Fixed Louver Model GAFL Extruded Aluminum Drainable Blade Fixed Louver Model DFL Extruded Aluminum Combination Louver/Damper Model ACL Installation Instructions Model AFL/GFL Installation Instructions Model AAFL/GAFL Installation Instructions Model DFL Installation Instructions Model ACL Installation Instructions Model ACL Optional Motor Kit
3 Louver SeLection Guide Select Models AFL/GFL: When you need Excellent resistance to rain and weather (water penetration) while providing minimum resistance to airflow (pressure drop) at an economical price. 4 deep channel frame with non-drainable fixed blades, K-style, 45 degrees. Installed into an opening or ductwork and NO flange is needed. Beginning water penetration of 709 fpm. Select Models AAFL/GAFL: When you need Excellent resistance to rain and weather (water penetration) while providing minimum resistance to airflow (pressure drop) and you need adjustability in the sizing (width). 4 deep flanged frame with non-drainable fixed blades, J-style, 45 degrees. Installed into an opening and a flange is needed. Beginning water penetration of 766 fpm. Select Model DFL: When you need Superior resistance to rain and weather (water penetration) while providing minimum resistance to airflow (pressure drop). Best performance. 4 deep channel frame with drainable fixed blades, 45 degrees. Installed into an opening or ductwork and NO flange is needed. Beginning water penetration of 910 fpm. Select Model ACL: When you need Superior resistance to rain and weather (water penetration) while providing minimum resistance to airflow (pressure drop) and you need the ability to close the opening off. Combination fixed louver and adjustable damper in one frame. 4 deep channel frame with drainable fixed blades in the front and adjustable blades in the back, 45 degrees. Can be motorized or manually operated. Installed into an opening or ductwork and NO flange is needed. Beginning water penetration is above 1250 fpm. (1250 fpm is the maximum test capabilities) Sizing for ALL Louver Models: Sizing: Take your Design CFM and divide it by the Maximum Recommended Velocity for your Model (Beginning Water Penetration fpm). This will give you your Minimum Required Free Area to select your louver size. Go to the Free Area Chart and select your louver size. Example (Model AFL): o Design CFM is 5,000. 5,000/709 fpm = 7.06 sq. feet required. Approximate louver size will be: 48 x 48 (7.07 sq. ft.). Terminology: Water Penetration the free area velocity at which water begins to pass through the louver. Pressure Drop the difference between the pressures on each side of the louver. Free Area the minimum area through which air can pass; it varies with louver size and/or design. Drainable blades utilizes a gutter at the leading edge of the blade to channel water out to the jambs, where the water is then drained to the bottom of the unit and away from the opening. This will eliminate any cascading of water from blade to blade. Best performing design. K-style / J-style blades these blade designs are typically used in exhaust applications or where water penetration is not an issue. Water will cascade from blade to blade. Most economical design. 3
4 SUBMITTAL DRAWINGS 4
5 Aluminum Fixed louver model AFl Heavy duty modular construction designed to protect the air intake and exhaust openings in the exterior walls of any building from rain and weather while still providing efficient airflow. Aluminum finish is ready for you to paint in the field or leave as mill finish. Standard Construction: Frame 4 deep channel x.060 thick Aluminum. Blades K style,.060 thick Aluminum, positioned at a 45 degree angle and spaced approximately 4 centers. Construction Tabbed. Birdscreen ½ Flattened Aluminum in a removable frame mounted on the interior. Finish Mill. Minimum Size 12 W x 12 H Maximum Single Section Size 48 W x 72 H Sizes over 48 Wide constructed in multiple sections. Modular design provides seamless mullions from the front side. No need for mullion covers. A 4" B front view side view Note: Above A and B dimensions are undersized by ½ + or normal tolerance of
6 Model AFl Louver Height in inches Free area Chart (Sq. ft.): Louver Width in inches Note: listed widths over 48" built in two panels. estimated Free Area calculations are based upon AMCA standard 500-l, actual performance may vary. PreSSure DroP Standard Air lbs per cubic foot Test size 48 x 48 (Intake) Ratings do not include the effect of a birdscreen 0.30 Water Penetration Standard Air lbs per cubic foot Test size 48 x 48 for a 15 minute duration 1 Pressure (in. wg) 0.1 Water Penetration (oz. water/sq. ft. Free Area) Free Area Velocity (fpm) Free Area Velocity (fpm) The beginning point of water penetration at.01 oz./sq. ft. is 709 fpm free area velocity. Air Conditioning Products certifies that the Model AFl was tested according to AMCA Standard 500. These tests were performed under certain sets of laboratory conditions. These performance ratings do not guarantee that other environmental conditions may actually occur. Use safety factors when selecting louver sizes based upon performance. Limited warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 6
7 Galvaneal Steel Fixed louver Model GFl Heavy duty modular construction designed to protect the air intake and exhaust openings in the exterior walls of any building from rain and weather while still providing efficient airflow. Galvaneal Steel finish is ready for you to paint in the field or leave as mill finish. Standard Construction: Frame 4 deep channel x 16 gauge A-60 Galvaneal Steel. Blades K style, 16 gauge A-60 Galvaneal Steel, positioned at a 45 degree angle and spaced approximately 4 centers. Construction Tabbed. Birdscreen ½ Flattened Aluminum in a removable frame mounted on the interior. Finish Mill. Minimum Size 12 W x 12 H Maximum Single Section Size 48 W x 72 H Sizes over 48 Wide constructed in multiple sections. Modular design provides seamless mullions from the front side. No need for mullion covers. A 4" B front view side view Note: Above A and B dimensions are undersized by ½ + or normal tolerance of
8 Model GFl Louver Height in inches Free area Chart (Sq. ft.): Louver Width in inches Note: listed widths over 48" built in two panels. estimated Free Area calculations are based upon AMCA standard 500-l, actual performance may vary. PreSSure DroP Standard Air lbs per cubic foot Test size 48 x 48 (Intake) Ratings do not include the effect of a birdscreen 0.30 Water Penetration Standard Air lbs per cubic foot Test size 48 x 48 for a 15 minute duration 1 Pressure (in. wg) 0.1 Water Penetration (oz. water/sq. ft. Free Area) Free Area Velocity (fpm) Free Area Velocity (fpm) The beginning point of water penetration at.01 oz./sq. ft. is 709 fpm free area velocity. Air Conditioning Products certifies that the Model GFl was tested according to AMCA Standard 500. These tests were performed under certain sets of laboratory conditions. These performance ratings do not guarantee that other environmental conditions may actually occur. Use safety factors when selecting louver sizes based upon performance. Limited warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 8
9 Aluminum AdjustAble Width Fixed louver model AAFl The Model AAFL is an Adjustable Flanged Frame Aluminum Louver. The width is adjustable and has end stops to help prevent separation of the blades. It is designed to protect the air intake or exhaust openings in the exterior walls of any building from rain and weather while still providing efficient airflow. The Aluminum finish is ready for you to paint in the field or leave as mill finish. Standard Construction: Frame 4 deep x 2 flanged x.040 thick Aluminum. Blades J style,.040 thick Aluminum, positioned at a 45 degree angle and spaced approximately 4 centers. Adjustable width. Construction Tabbed and riveted. Mounting Holes Pre-punched 9 /32 x 1 /2 holes. Birdscreen 1 /2 Flattened Aluminum mounted on the interior. Finish Mill. GAlvAniZed GAlvAniZed AdjustAble AdjustAble louver louver A A 4" D 4" D 3" TYP. 3" TYP. C B C B ADJUSTABLE WIDTH (IN.) A 12 TO TO TO TO TO TO TO TO TO TO TO TO 48 ADJUSTABLE FIXED FIXED WIDTH (IN.) HEIGHT HEIGHT A B C 12 TO TO TO TO TO TO TO TO TO TO TO TO " TYP. 2" TYP. FrOnt VieW FrOnt VieW Side VieW Side VieW Note: Above dimensions + or - normal tolerance of.0625" 9 UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES TOLERANCES DECIMALS ANGULAR UNLESS OTHERWISE SPECIFIED: AIR CON DIMENSIONS ARE IN INCHES AIR CONDITIONING PRODUCTS C TOLERANCES ROMUL ROMULUS DECIMALS MI. ANGULAR XX +_.062 +_ 1
10 ModeL AAFL Sizing and Free Area Chart: outside outside INSIde INSIde NUMBeR MINIMUM MAXIMUM WIdTH (In.) HeIGHT (In.) HeIGHT (In.) WIdTH (In.) of FRee AReA FRee AReA A B C d BLAdeS* (Sq. Ft.) (Sq. Ft.) 16 TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO (*) Not including integral top and bottom blades. PreSSure DroP Standard Air lbs per cubic foot Test size 48 x 48 (Intake) Ratings do not include the effect of a birdscreen 0.30 WAter PenetrAtion Standard Air lbs per cubic foot Test size 48 x 48 for a 15 minute duration 1 Pressure (in. wg) 0.1 Water Penetration (oz. water/sq. ft. Free Area) Free Area Velocity (fpm) Free Area Velocity (fpm) The beginning point of water penetration at.01 oz./sq. ft. is 766 fpm free area velocity. Air Conditioning Products certifies that the Model AAFL was tested according to AMCA Standard 500. These tests were performed under certain sets of laboratory conditions. These performance ratings do not guarantee that other environmental conditions may actually occur. Use safety factors when selecting louver sizes based upon performance. Limited Warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 10
11 Galvanized adjustable Width Fixed louver Model GaFl The Model GAFL is an Adjustable Flanged Frame Galvanized Steel Louver. The width is adjustable and has end stops to help prevent separation of the blades. It is designed to protect the air intake or exhaust openings in the exterior walls of any building from rain and weather while still providing efficient airflow. The Galvanized Steel finish is ready for you to paint in the field or leave as mill finish. Standard Construction: Frame 4 deep x 2 flanged x 19 gauge G-90 Galvanized Steel. Blades J style, 19 gauge G-90 Galvanized Steel, positioned at a 45 degree angle and spaced approximately 4 centers. Adjustable width. Construction Tabbed and Tog-L-Locked. Mounting Holes Pre-punched 9 /32 x 1 /2 holes. Birdscreen 1 /2 Flattened Aluminum mounted on the interior. Finish Mill. Galvanized Galvanized adjustable adjustable louver louver A D A D 4" 4" 3" TYP. 3" TYP. C B C B ADJUSTABLE WIDTH (IN.) A 12 TO TO TO TO TO TO TO TO TO TO TO TO 48 ADJUSTABLE FIXED FIXED WIDTH (IN.) HEIGHT HEIGHT A B C 12 TO TO TO TO TO TO TO TO TO TO TO TO " TYP. 2" TYP. FrOnt VieW FrOnt VieW Side VieW Side VieW Note: Above dimensions + or - normal tolerance of.0625" 11 UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES TOLERANCES DECIMALS ANGULAR UNLESS OTHERWISE SPECIFIED: AIR CON DIMENSIONS ARE IN INCHES AIR CONDITIONING PRODUCTS C TOLERANCES ROMUL ROMULUS DECIMALS MI. ANGULAR XX +_.062 +_ 1
12 ModeL GAFL Sizing and Free Area Chart: outside outside INSIde INSIde NUMBeR MINIMUM MAXIMUM WIdTH (In.) HeIGHT (In.) HeIGHT (In.) WIdTH (In.) of FRee AReA FRee AReA A B C d BLAdeS* (Sq. Ft.) (Sq. Ft.) 16 TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO TO (*) Not including integral top and bottom blades. PreSSure DroP Standard Air lbs per cubic foot Test size 48 x 48 (Intake) Ratings do not include the effect of a birdscreen 0.30 WAter PenetrAtion Standard Air lbs per cubic foot Test size 48 x 48 for a 15 minute duration 1 Pressure (in. wg) 0.1 Water Penetration (oz. water/sq. ft. Free Area) Free Area Velocity (fpm) Free Area Velocity (fpm) The beginning point of water penetration at.01 oz./sq. ft. is 766 fpm free area velocity. Air Conditioning Products certifies that the Model GAFL was tested according to AMCA Standard 500. These tests were performed under certain sets of laboratory conditions. These performance ratings do not guarantee that other environmental conditions may actually occur. Use safety factors when selecting louver sizes based upon performance. Limited Warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 12
13 EXTRUDED AlUminUm DRAinABlE BlADE FiXED louver MODEL DFL Heavy duty Extruded Aluminum construction designed to protect the air intake and exhaust openings in the exterior walls of any building from rain and weather while still providing efficient airflow. The drainable blade design provides the best protection against water entering the opening by channeling water away from the blades and down the jambs. This eliminates water cascading from blade to blade. Aluminum finish is ready for you to paint in the field or leave as mill finish. Standard Construction: Frame 4 deep channel x.080 thick Extruded Aluminum. Blades Drainable style,.080 thick Extruded Aluminum, positioned at a 45 degree angle and spaced approximately 4 centers. Construction Screwed. Birdscreen ½ Flattened Aluminum in a removable frame mounted on the interior. Finish Mill. Minimum Size 12 W x 12 H Maximum Single Section Size 48 W x 60 H 4" A B side view front view Note: Above A and B dimensions are undersized by ½ + or normal tolerance of
14 MoDEl DFl Louver Height in inches Free area Chart (Sq. ft.): Louver Width in inches Note: listed widths over 48" built in two panels. Estimated Free Area calculations are based upon AMCA standard 500-l, actual performance may vary. PreSSure DroP Standard Air lbs per cubic foot Test size 48 x 48 (Intake) Ratings do not include the effect of a birdscreen 0.30 Water Penetration Standard Air lbs per cubic foot Test size 48 x 48 for a 15 minute duration 1 Pressure (in. wg) 0.1 Water Penetration (oz. water/sq. ft. Free Area) Free Area Velocity (fpm) Free Area Velocity (fpm) 1150 The beginning point of water penetration at.01 oz./sq. ft. is 910 fpm free area velocity. Air Conditioning Products certifies that the Model DFl was tested according to AMCA Standard 500. These tests were performed under certain sets of laboratory conditions. These performance ratings do not guarantee that other environmental conditions may actually occur. Use safety factors when selecting louver sizes based upon performance. Limited warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 14
15 ExtrudEd Aluminum CombinAtion louver / damper MODEL ACL Heavy duty Extruded Aluminum construction designed to protect the air intake and exhaust openings in the exterior walls of any building from rain and weather while still providing efficient airflow. The drainable blade design provides the best protection against water entering the opening by channeling water away from the blades and down the jambs. This eliminates water cascading from blade to blade. The adjustable rear blades allow for tight shutoff of the opening when needed. Standard Construction: Frame 4 deep channel x.080 thick Extruded Aluminum. Blades Drainable style,.080 thick Extruded Aluminum, positioned at a 45 degree angle and spaced approximately 4 centers. Seals Extruded TPV. 4" A Linkage On-blade type with a Thumb Screw Operator as standard. Birdscreen ½ Flattened Aluminum in a removable frame mounted on the exterior. Construction Screwed. B Finish Mill. Minimum Size 18 W x 18 H front view Maximum Single Section Size 48 W x 60 H Options (at additional cost) 100 to 240 VAC, 50/60 Hz Motor Pack. SCREEN BLADE IN CLOSED POSITION BLADE IN OPEN POSITION THUMB SCREW FOR BLADE OPENING AND CLOSING Note: Above A and B dimensions are undersized by ½ + or normal tolerance of /8" 6-5/8" side view (w/ std. thumb screw) /8" side view (w/ OptiOnal motor)
16 MODEl ACl Louver Height in Inches Free area Chart (Sq. ft.): Louver Width in Inches Note: listed widths over 48" built in two panels. Estimated Free Area calculations are based upon AMCA standard 500-l, actual performance may vary. PreSSure DrOP Standard Air lbs per cubic foot Test size 48 x 48 (Intake) Ratings do not include the effect of a birdscreen 0.30 Water PenetratIOn Standard Air lbs per cubic foot Test size 48 x 48 for a 15 minute duration 1 Pressure (in. wg) 0.1 Water Penetration (oz. water/sq. ft. Free Area) Free Area Velocity (fpm) Free Area Velocity (fpm) 1400 The beginning point of water penetration at.01 oz./sq. ft. is above 1250 fpm free area velocity. Air Conditioning Products certifies that the Model ACl was tested according to AMCA Standard 500. These tests were performed under certain sets of laboratory conditions. These performance ratings do not guarantee that other environmental conditions may actually occur. Use safety factors when selecting louver sizes based upon performance. limited warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air conditioning products co Ecorse Road Romulus, MI acpshutters.com 16
17 INSTALLATION INSTRUCTIONS 17
18 INSTALLATION INSTRUCTIONS MODULAR FixeD LOUveR MODeL AFL/GFL Description The Modular Fixed Louvers are designed to be installed individually or in multiples providing seamless mullions from the front side. Heavy gauge.060 Aluminum, or 16 gauge A-60 Galvaneal ready for your custom paint color. Both aluminum and galvaneal models are 4 deep and come with birdscreen installed. Installation ENSURE STRUCTURAL INTEGRITY OF WALL BEFORE BREACHING. 1. Clean the opening prior to installation. 2. Wall opening should be 1/4 to 1/2 larger than the OD of the louver. Note: For multiple wide installations as shown in Figure 1, each panel will be undersized by 1/2 plus the frame overlap of 1" for a total of 2". 3. Install head and sill flashing if needed in wall opening as per Figure Insert unit into opening and fasten as per Figure To install multiple wide units: Remove birdscreen. Slide c channel flange behind flat flange as shown in Figure 1. Replace birdscreen and re-fasten through the birdscreen and the flanges of both units as per Figure 1. Use clip angles to secure frame(s) to the wall as per Figure To install multiple high units: Remove birdscreen. Apply bead of caulk between units. Stack units as per Figure 2 and secure by driving corrosion resistant sheet metal screws through the top and bottom at intervals no more than 18" with a minimum of two fasteners per side. Use clip angles to secure frame(s) to the wall as per Figure 3. Re-install birdscreen. TOP VIEW - multiple WIdE INsTallaTION BaCK screen FRONT Figure 1 HEAD FLASHING CLIP ANGLES SCREEN HEAD FLASHING CLIP ANGLES SCREEN WOOD, BRICK OR CONCRETE WALL SILL FLASHING CLIP ANGLES SILL FLASHING METAL CURTAIN WALL CLIP ANGLES Note: Caulking, mounting hardware or flashing materials are not supplied with louver Figure 3 Figure 2 Limited Warranty all products manufactured are warranted by air Conditioning Products Company (acp) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. acp will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless acp has given prior written permission, nor will acp be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 18
19 INSTALLATION INSTRUCTIONS ADJUSTABLE FRAME LOUVERS FOR INTAKE/EXHAUST Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. General Safety Information WARNING: USE CAUTION WHEN HANDLING SHEET METAL PRODUCTS. PROTECTION SHOULD BE USED TO AVOID CONTACT WITH SHARP EDGES OR INJURY MAY OCCUR. Unpacking When unpacking, carefully remove louver from carton and inspect for any damage that may have occurred during transit. Installation Description The Adjustable Frame Intake/Exhaust Louvers are fabricated from galvanized steel or.040 aluminum. Both galvanized and aluminum products are 4" deep with 2" face flange and come with rear mounted bird screen. Fixed height is standard and width is adjustable. Louvers have end stops to help prevent separation of sections. Louvers may be used in HVAC intake and exhaust systems and many air moving applications. They are usually installed in openings of interior or exterior walls, roof penthouses and ductwork. The Adjustable Frame Intake/Exhaust Louvers are galvanized steel or mill finish aluminum, and may be painted, provided proper surface pre-treatment is performed prior to paint application. Note that unit must be adjusted to its final width prior to painting. Refer to paint manufacturers instructions prior to pretreating and painting. 1. To install the louver, first prepare the wall or duct opening to accept the louver. The wall opening should be 1 / 4 " to 1 / 2 " larger than the final fixed dimension of the louver. Make sure that the opening is plumb and level, and sufficient structural support is provided, as the louver is not load bearing. 2. After the opening is prepared, measure its width by height and, on the ground, adjust the louver to the required opening width. 3. Carefully extend the louvers to the desired width. Take care not to use excessive force, as it is possible to overcome the stops. Open the louver evenly to prevent jamming. Do not exceed maximum width dimension. (See Figure 1) Figure 1 PARALLEL AVOID NOTE: When louver is adjusted to proper width, both jambs must be parallel. AFL
20 ADJUSTABLE FRAME LOUVERS FOR INTAKE/EXHAUST 4. Once the unit is adjusted to the desired width, drill each louver on rear, 1" from the seam, and attach screen and both louver sections using provided hardware. (See Figure 2) CAULK INSIDE CORNER 1" Installation (continued) CAULK Figure 2 WASHER SECURE AFTER ADJUSTING TO PROPER WIDTH S/M SCREW 5. Caulk louvers on rear of face flange on top, bottom and sides and inside top and bottom corners prior to installation to prevent water from entering the building as shown in Figures 2 and Secure the louver into opening selecting the most suitable method as shown in Figure Use corrosion protected fasteners to secure the louver in the opening. Once louver is adjusted to the desired width, drill top and bottom through both sections. Hardware should be spaced no more than 18" apart, and all sides should have a minimum of two fasteners. 8. If installation requires the louver to be connected to a duct system, then any ductwork, fans or dampers should be supported by the building structure, and should be sealed to the louver. Installation Methods SCREEN Figure 4 ATTACHMENT THROUGH FACE FLANGE Figure 3 ANCHOR BOLTS MINIMUM 1/4" - 18" ON CENTER AROUND PERIMETER (MINIMUM 2 PER SIDE) CLIP ANGLES MINIMUM WOOD, BRICK CAULK 1" CAULK 4 SIDES SCREEN OR CONCRETE WALL 2" TYP. H (FIXED) METAL CURTAIN WALL HEAD FLASHING - FULL WIDTH (FURNISHED BY OTHERS) CAULK W (ADJUSTABLE) SILL FLASHING - FULL WIDTH - SEALED ON BOTH ENDS (FURNISHED BY OTHERS) WINDOW FRAME OR STEEL FRAME LIMITED WARRANTY All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. Manufactured for Air Conditioning Products Co Ecorse Raod Romulus, MI NOTE: CAULKING, CLIP ANGLES, MOUNTING HARDWARE OR FLASHING MATERIALS ARE NOT SUPPLIED WITH LOUVER Vertical Section Maintenance Periodically clean the screen to prevent buildup of dust and accumulated dirt which could reduce the air flow. 20
21 INSTALLATION INSTRUCTIONS DRAINABLE FIXED LOUVERS MODEL DFL Description The Extruded Aluminum Drainable Fixed Louvers are designed to protect the air intake and exhaust openings in the exterior walls of any building from rain and weather while still providing efficient air flow. Heavy Duty 4 deep.080 thick frame and.080 thick extruded aluminum louvers positioned at 45 degrees and spaced at approximately 4 centers and comes with birdscreen installed. Installation ENSURE STRUCTURAL INTEGRITY OF WALL BEFORE BREACHING. 1. Clean the opening prior to installation. 2. Wall opening should be ¼ to ½ larger than the OD of the louver. 3. Install head and sill flashing if needed in wall opening as per Figure Use clip angles to attach frame to walls as per Figure 2. 4" A HEAD FLASHING HEAD CLIP ANGLES CLIP ANGLES FLASHING SCREEN SCREEN B SILL FLASHING WOOD, BRICK OR CONCRETE WALL CLIP ANGLES Figure 1 Figure 2 SILL FLASHING METAL CURTAIN WALL CLIP ANGLES Limited Warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 21
22 INSTALLATION INSTRUCTIONS Combination Louver/DamPer model acl Description The Extruded Aluminum Combination Louver/Damper is designed to protect the air intake and exhaust openings in the exterior walls of any building from rain and weather while still providing efficient air flow. Heavy Duty 4 deep.080 thick frame and.080 thick extruded aluminum louvers positioned at 45 degrees and spaced at approximately 4 centers. The rear blade is adjustable to close the opening off if needed. Optional VAC 50/60 Hz actuator available. Installation ENSURE STRUCTURAL INTEGRITY OF WALL BEFORE BREACHING. 1. Clean the opening prior to installation. 2. Wall opening should be ¼ to ½ larger than the OD of the louver. 3. Install head and sill flashing if needed in wall opening as per Figure Use clip angles to attach frame to walls as per Figure Adjust the Thumb Screw Operator as needed. Thumb Screw Operator HEAD FLASHING SCREEN CLIP ANGLES HEAD FLASHING SCREEN CLIP ANGLES SILL FLASHING WOOD, BRICK OR CONCRETE WALL CLIP ANGLES Figure 1 SILL FLASHING METAL CURTAIN WALL CLIP ANGLES Limited Warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 22
23 INSTALLATION INSTRUCTIONS Combination Louver/DamPer optional motor Kit Description Optional VAC 50/60 Hz power open spring return motor kit that returns to the closed position in the event of loss of power. The motor kit comes pre-assembled for easy installation. Installation For use with Model ACL Combination Louver/Dampers 1. Remove the Thumb Screw Bracket from the bottom of the existing louver frame. 2. Bolt the new motor bracket to the louver frame using the predrilled mounting holes. 3. Insert the linkage rod into the crankarm ball joint. 4. Push the linkage rod upward until the louver is fully closed. 5. Tighten the ball joint set screw to secure the linkage rod. 6. Wire the motor as shown in Figure to to VAC 240 VAC N L1 N L1 N L2 N L2 1 Neutral 1 Neutral 2 Hot2 Hot 1 S1 S1 S2 S3 NG S2 S3 NO NG 0 to 0 95 to 95 NO 2 4 Figure 1 - Wiring Diagram TFC120-S TFC120-S DAY DAY Figure Optional Motor Kit Parts List Ref. No. Description Part Number 1 50/60 Hz, VAC Actuator TFC120-S 2 Motor bracket Included 3 Crankarm Included 4 Ball Joint Included 5 Retaining clip Included Limited Warranty All products manufactured are warranted by Air Conditioning Products Company (ACP) to be free from original defects in workmanship for a period of one year from date of shipment, under conditions of normal use and service. ACP will replace or repair any defective parts upon return to our plant, freight prepaid. This limited warranty will, in no way, include the payment of labor charges for field replacement of defective parts, installation, repairs of adjustments, or any other work done. Back charges will not be accepted for any reason unless ACP has given prior written permission, nor will ACP be responsible for consequential damages of any character, no limited warranty expressed or implied will supersede the foregoing. manufactured for air Conditioning Products Co Ecorse Road Romulus, MI acpshutters.com 23
24 Air Conditioning Products Company (ACP) is family owned and operated for 3 generations. For over 60 years, ACP has been an industry leader specializing in manufacturing shutters, dampers, and louvers for the HVAC industry. Our broad customer base includes OEM s, leading HVAC manufacturers, national and regional distributors, as well as industry specific companies. Located in Romulus, MI (near Detroit), our state of the art manufacturing facility (over 100,000 sq. ft. of manufacturing space) allows us to quickly deliver products that will fulfill your requirements for quality and reliability in most air control applications. Our high volume capability combined with short lead times allows us to handle orders of all sizes and quantities. ACP s products are used in commercial/industrial, agricultural, and residential applications. In an ongoing effort to be a leader in our industry, we are active members of the Air Movement and Control Association International (AMCA) and its mission to promote the health and growth of the air movement and control industry consistent with the interest of the public. For more information about our product offering, visit us at
EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction
Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
Miami-Dade Qualified Drainable Blade Louvered Penthouse
Application and Design is a gravity intake or exhaust louvered penthouse. Model incorporates high performance horizontal drainable style blades. Meets the performance requirements established by the Florida
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
security products metric sizes Redefine your comfort zone. www.titus-hvac.com
metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table
Clad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
Important Information for Installer & Homeowner
Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
AA Solar and Sun Power Plus
AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Installation Instructions
Installation Instructions One-Piece Deep Wall Sleeve For Use with Packaged Terminal Units Please read these instructions completely before attempting installation. NOTE: Ensure that the unit is only installed
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
ROOF TOP MOUNTED Air Handler Specification
ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
AMD-33 Air Measuring Station with VCD-33 Control Damper
Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
Installation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Vinyl Greenhouse Window Page 2 of 6 New Contruction Installation Instructions
New Construction Installation Instructions EPLACEMENT Installation Instructions Page 2 of 6 New Contruction Installation Instructions 1. Frame rough opening equal to window call out size. ough opening
Calvert USA, Inc. Attic Stairs
Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,
Owner's Manual & Assembly Instructions
Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
Installing Shutters using Fasteners
Installing Shutters using Fasteners Electric drill, ¼" drill bit, 3 8" drill bit, hammer, and shutter fasteners. (¼" carbide drill bit is required for stucco, hardboard, fiber cement, brick or masonry.)
FIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
InsulView Window Installation Instructions
InsulView Window Installation Instructions 1. The entire building is normally sheeted with the 2" 2 ½ OR 3 wall panel and the windows installed at a later time. A window retrofit of an existing building
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
INSTRUCTION BOOK FOR. Lace And Grommet Theater-Type Screens
INSTRUCTION BOOK FOR Lace And Grommet Theater-Type Screens Pre-Installation Da-Lite Lace and Grommet screens are custom made to meet the requirements for large surface installation of a relatively permanent
Roof Curbs, Extensions and Equipment Supports
Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....
AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.
Application and esign Thermal ispersion Air Measuring Station with VC-23 Control amper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
Solar Mounting System
Xiamen Antai New Energy Tech.Co., Ltd Installation Manual Antai Rail Solar Mounting System (Flat Roof Solution) Version 1.1 Office Add: 508#, North Tower, Guangxia Building Huli Torch Hi-tech Zone, Xiamen,
CLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
Sash Replacement Guide
for Andersen 200/400 Series Awning Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete this procedure, call Andersen at 1-888-888-7020
Customer Service 800.780.8889 or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips
reflect your style TM Customer Service 800.780.8889 or visit us online at smithnoble.com Wood Shutters Step by Step Installation Troubleshooting Tips Easy Care Instructions STEP 1 Your New Shutter Thank
Retractable Screen. Replacement Screen Instructions
Retractable Screen Patent Pending Replacement Screen Instructions For RTS, RET, & RTM Products ATTENTION! Retractable screens are not intended to provide security or provide for the retention of objects,
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
CLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame
Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
Model # 940P-V6. Page 1 of 11
Model # 940P-V6 Page 1 of 11 Page 2 of 11 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all items for one full year to be free of defects in
INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg
Thank you for selecting JeLd-weN products. Attached are JeLd-weN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to
Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
2. Division 05 Structural Steel Framing for steel framework requirements
SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division
Air Conditioner Duct Construction & Repair
PROPER ROOF AIR CONDITIONER MOUNTING At Newmar, there are two different models of air conditioners available on all towable and motorized units. The different models are the Dometic Brisk and Penguin models,
DBF 4XL Dryer Booster Fans
Installation and Operation Manual Item #: 401315 Rev Date: 121514 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll
Installation Guide for Andersen Architectural Wood Inswing Entry Doors
Installation Guide for Andersen Architectural Wood Inswing Entry Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are
Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
SECTION 11014 WINDOW WASHING SYSTEMS
SECTION 11014 WINDOW WASHING SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes, but is not limited to, design and furnishing portable davits, davit sleeves, dvit bases, four (4) removable outriggers,
INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW
Vinyl Windows and Doors Manufactured by Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Lea las instrucciones en español en el reverso.
Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.
P-5 The P-5 is hot forged from carbon steel. The formed head provis spherical seating that the Lifting Eye engages, while a disc-shaped foot is embedd in the concrete. Due to its being a forged part, the
UPBLAST & HOODED PROPELLER ROOF VENTILATORS
The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust
By SP Partners, LLC. www.rainbowatticstair.com INSTALLATION GUIDE. Prestige
By SP Partners, LLC www.rainbowatticstair.com INSTALLATION GUIDE Prestige IMPORTANT READ THIS FIRST Inspect stair for any damage prior to installation. Stair is NOT to be installed while home is under
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps
WINDOW PANNING AND TRIMS
OCTOBER, 2010 PANNING AND TRIMS GENERAL INFORMATION 1 EXTERIOR PANNING Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows.
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011
WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 [email protected] 1 Disclaimer The following warranty
Installation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A 05-21-09
PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE. INSTRUCTIONS 1) FOR EZ-ACCESS PATHWAY RAMP WITH HANDRAILS 850 pound weight capacity. Available in 4, 6, 8 & 10 lengths.
SECTION 08560 SERIES 1500 VINYL PATIO DOORS
SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
Rating when used as a weight carrying hitch without spring bars:
BOLT-TOGETHER WEIGHT DISTRIBUTING HITCH SYSTEM Rating when used as a weight distributing hitch with spring bars: Part Number 48051 4805 48053 48054 Max Tongue Weight 550 Ibs. 750 Ibs. 1000 Ibs. 1400 lbs.
Architect/Contractor Information Package
Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Protecting Your Home From Hurricane Wind Damage
T H E W I N D Protecting Your Home From Hurricane Wind Damage During a hurricane, homes may be damaged or destroyed by high winds and high waves. Debris can break windows and doors, allowing high winds
Installation Manual for STANDING SEAM ROOFING
Installation Manual for STANDING SEAM ROOFING Absolute Steel Toll Free 877-833-3237 / Phone 480-768-1618 / Fax 480-768-1514 www.metalroofingsource.com Standing Seam features approximately one-inch high
Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023
Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural
PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB
OVERVIEW TYPE: GGB All composite construction Rigid extruded upvc aerofoil blade section Integral blade seals for low leakage operation Individual blades driven via reinforced styrene gear wheels in maintenance
Active and Passive Sash Replacement
for Andersen Gliding Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete the procedure, call Andersen at 1-888-888-7020 for
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
AZEK Rail Install Guide
TRIM MOULDING DECK PORCH RAIL PAVERS AZEK Rail Install Guide Installing AZEK Rail with Glass Infill... 2 Installing AZEk Rail Stairs with Glass Infill... 9 Notes...14 Please read all instructions completely