FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.
|
|
|
- Cameron Powell
- 9 years ago
- Views:
Transcription
1 FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds 2-7/16" (61.9) 1-3/16" (46) Jamb Break-Off Tool Using the break-off tool, bend clip back and forth toward opposite face of frame. Do not bend past the outside face to avoid deforming the face. Jamb NOTE: Using pliers to break off the Corner Clip may result in damage to the face of the frame.
2 FRAME PROFILE MASONRY MASONRY KD G PROFILE - CORNER DETAILS #8 Screw Required on all fire rated KD frames Bend Tabs Jamb Corner Assembly Head MASONRY KD 2" FACE FLUSH FRAME UNEQUAL RABBET 1-15/16" (49.2) VARIES 1-9/16" (39.7) 5/8" (15.9) 2" (50.8) M 1/2" (12.7) KD M Type Flush Gauge - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) Variable Soffit Jamb Depth 4-1/2" (114.3) thru 14" (355.6) 1/8" (3.2) Increments Available with 4" (101.6) Face Heads NOTE: 5-3/4 (146.1) jamb depth standard with 7/16" (11.1) returns to provide 4-7/8" (123.8) throat opening.
3 FRAME PROFILE MASONRY MASONRY 1", 1-1/4", 1-1/2", 1-3/4", FACE FLUSH KD FRAME UNEQUAL RABBET 1-15/16" (49.2) VARIES 1-9/16" (39.7) 5/8" (15.9) 1" (25.4) 1-1/4" (31.8) 1-1/2" (38.1) 1-3/4" (44.5) 1/2" (12.7) M KD M Type Flush Gauge - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) Variable Soffit Jamb Depth 4-1/2" (114.3) thru 14" (355.6) 1/8" (3.2) Increments Not available with 4" (101.6) Face Heads NOTE: When CCW material is used in conjunction with above, coordinate rabbet and face dimensions 5-3/4" (146.1) jamb depth standard with 7/16" (11.1) returns to provide 4-7/8" (123.8) throat opening. MASONRY FLUSH KD FRAME EQUAL RABBET 1-15/16" (49.2) OR 1-9/16 (39.7) VARIES 1-15/16" (49.2) OR 1-9/16 (39.7) 5/8" (15.9) 1" (25.4) 1-1/4" (31.8) 1-1/2" (38.1) 1-3/4" (44.5) 2" (50.8) M 1/2" (12.7) KD M Type Flush Gauge - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) Variable Soffit Jamb Depth 4-7/8" (114.3) thru 14" (355.6) 1/8" (3.2) Increments Available with 4" (101.6) Face Heads with 2" Face Jambs Only NOTE: When CCW material is used in conjunction with above, coordinate rabbet and face dimensions 5-3/4" (146.1) jamb depth standard with 7/16" (11.1) returns to provide 4-7/8" (123.8) throat opening.
4 FRAME PROFILE MASONRY MASONRY FACE FLUSH KD FRAME CASED OPENING VARIES 3" (76.2) MINIMUM 1" (25.4) 1-1/4" (31.8) 1-1/2" (30.1) 1-3/4" (44.5) 2" (50.8) 1/2" (12.7) MK KD MK Type Flush Gauge - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) Jamb Depth 3" (76.2) thru 14" (355.6) 1/8" (3.2) Increments NOTE: Available with 4 (101.6) face head with 4-1/2" (114.3) minimum jamb depth, 5-3/4" (146.1) jamb depth standard with 7/16" (11.1) returns to provide 4-7/8 (123.8) throat opening. NOTE: Total door only may be labeled. MASONRY FLUSH KD G PROFILE FRAME 1-15/16" (49.2) OR 1-9/16" (39.7) VARIES 5/8" (15.9) 2" (50.8) G 2-5/8" (66.7) 1/2" (12.7) KD G Type Flush Gauge - 18 GA. (1.2), 16 GA. (1.4), 14 GA. (1.9) Jamb Depth 3" (76.2) thru 14" (355.6) 1/8" (3.2) Increments Min. 4" Jamb Depth for Labeled Frame with 1-15/16" Rabbet and 3-1/4" Jamb Depth for 1-9/16" Rabbet NOTE: 2 (50.8) and 2-5/8" (66.7) face on jambs. NOTE: Available with 4" (101.6) face head with 4-1/2" (114.3) minimum jamb depth, 5-3/4" (146.1) jamb depth standard with 7/16" (11.1) returns to provide 4-7/8" (123.8) throat opening.
5 FRAME PROFILE MASONRY MASONRY KD 4" FACE HEAD #8 Screw Required on all fire rated KD frames Head Filler Corner Clip Bend Tabs MASONRY KD DOUBLE EGRESS FRAME #8 Screw Required on all fire rated KD frames Bend Tabs 1/2"* (12.7) 1-3/8" (34.9) 4-3/4" (120.6) TO 14" (355.6) Jamb DEM 2-5/8" (66.7) 1/2"* (12.7) 4-3/4" (120.6) TO 14" (355.6) 2" Head (50.8) GE 2-5/8" (66.7) * 5-3/4" (146.1) jamb depth has 7/16" (11.1) return
6 JAMB DEPTH OPTIONS FRAME JAMB OPTIONS FRAME PROFILE RATED MIN FRAME JAMB MAX FRAME JAMB 4" FRAME HEAD OPTION M - 4-7/8" 14 Y M Y 4-7/8" 14 Y MK - 3" 14 Y G - 3" 14 Y G Y 4" 14 Y DEM - 4-3/4" 14 Y DEM Y 4-3/4" 14 Y N - 4-7/8" 14 Y N Y 4-7/8" 14 Y CUST - 3-1/2" 20 Y CUST Y 4-1/2" 14 Y * Custom frames available. Contact factory for options.
7 ANCHOR TYPES STANDARD FOOT CLIPS 2" (50.8) STANDARD P0030 Standard Foot Clip 16 GA. (1.4) P GA. For face width over 4" P GA. P GA. 2" (50.8) 9/32" (7.1) DIA. Face Minus 3/8" (9.5) Label Requirements: Face Minus 1/2" (12.7) Maximum P0030 C Type Frame P0081 Double Egress Foot Clips Face Minus 3/8" (9.5) Label Requirements: Face Minus 1/2" (12.7) Maximum P0080 G Profile Jamb depth 4" (101.6) or less P0081 G Profile Greater than 4" (101.6) jamb depth
8 ANCHOR TYPES ADJUSTABLE FOOT CLIPS ADJUSTABLE FOOT CLIP 16 GA. (1.4) 5/8" (15.7) 3/4" (19.1) 1/4" (6.4) 1/2" (12.7) Anchor Part Number: P0078 Foot clip shipped loose with 2 #12 sheet metal screws 16 GA. (1.4) 3-5/8" (92) 4-7/8" (117.5) 9/32" (7.1) DIA. Per Jamb Depth Per Face Dimesion ADJUSTABLE FOOT CLIP - CASED OPENING 16 GA. (1.4) 5/8" (15.7) 3/4" (19.1) 16 GA. (1.4) 1/4" (6.4) 3-5/8" (92) 1/2" (12.7) Anchor Part Number: P0151 Foot clip shipped loose with 2 #12 sheet metal screws 4-7/8" (117.5) 9/32" (7.1) DIA. Per Jamb Depth Per Face Dimesion
9 ANCHOR TYPES STEEL STUD CHANNEL ANCHOR STEEL STUD CHANNEL ANCHOR Anchor Part Number: P0169 Order code loose: WSC Weld in steel stud anchor NOTE: Minimum face of 1-1/4" (31.8) required for this anchor type STEEL STUD CHANNEL ANCHOR - DOUBLE EGRESS Anchor Part Number: P0169 Order code loose: WSC Weld in steel stud anchor 1-1/4" (31.8) 1-11/16" (42.9) 5/8" (15.9) * 5-3/4" (146.1) jamb depth has 7/16" (11.1) return
10 ANCHOR TYPES WOOD STUD ANCHOR WOOD STUD ANCHOR SLIP in Wood Stud Anchor M Series Frame Only Order Code Loose: WS Anchor Part Number: (Specify Stud Size) A DIMENSIONS P /2 (88.9) STUD P /8 (92.1) STUD P /2 (139.7) STUD P /8 (142.9) STUD WELD in Wood Stud Anchor Order Code Loose: WWS Anchor Part Number: (Specify Stud Size) A DIMENSIONS P /2 (88.9) STUD P /8 (92.1) STUD P /2 (139.7) STUD P /8 (142.9) STUD 16 GA. (1.4) 3-1/4" (82.6) 16 GA. (1.4) 9/64" (3.6) DIA. A 1" (25.4) 9/64" (3.6) DIA. A 1" (25.4) WOOD STUD ANCHOR DOUBLE EGRESS SLIP in Wood Stud Anchor Order Code Loose: WS Anchor Part Number: (Specify Stud Size) A DIMENSIONS P /2 (88.9) STUD P /8 (92.1) STUD P /2 (139.7) STUD P /8 (142.9) STUD WELD in Wood Stud Anchor Order Code Loose: WWS Anchor Part Number: (Specify Stud Size) A DIMENSIONS P /2 (88.9) STUD P /8 (92.1) STUD P /2 (139.7) STUD P /8 (142.9) STUD 16 GA. (1.4) 16 GA. (1.4) 9/64" (3.6) DIA. A 1" (25.4) 9/64" (3.6) DIA. 1" (25.4) A NOTE: Specify Jamb or head anchor when ordering. Curries wood stud anchors can be used with wood and metal studs. Both are label approved.
11 ANCHOR TYPES MULTIPURPOSE ANCHOR MULTIPURPOSE ANCHOR Anchor Part Number: P0045 Anchor Code: MP Jamb Depths of 4-3/4" (120.7) thru 9-3/4" (247.6) 2" (50.8) Face Flush M Series or Drywall C Series 2 (50.8) X 2-5/8" (66.67) G Series or Drywall CG Series Bend or trim legs to suit wall conditions Number of stiffeners depend on jamb depths 5/32" (4) DIA. 18 GA. (1.4) Unequal rabbets only on masonry walls
12 ANCHOR TYPES MULTIPURPOSE ANCHOR INSTALLATION DRYWALL RETURN FRAME DETAIL A Push 50 Lift Up 20 DETAIL B Push DETAIL C DETAIL D P0045 DETAIL E 1. Bend legs of anchor 90 as shown in detail A (legs may have to be bent further in later steps). 2. Insert anchor into frame throat tilted at approximately a 50 angle as shown in detail B. 3. The anchor must also be inserted at approximately a 20 angle from the rabbets of the frame as shown in detail B. The flanges on the anchor must clear the backbend returns. 4. Twist the anchor into place by applying pressure in the opposite directions to each side of the anchor as shown in detail C. 5. Once the anchor has snapped into place, detail D, turn it up into the correct position as shown in detail E legs should be bent back to the original position if necessary.
13 ANCHOR TYPES MULTIPURPOSE ANCHOR INSTALLATION DRYWALL RETURN FRAME DETAIL A Push 50 Lift Up 20 DETAIL B Push DETAIL C DETAIL D P0045 INSTALLATION DETAIL E 1. Bend legs of anchor 90 as shown in DETAIL A (legs may have to be bent further in later steps). 2. Insert anchor into frame throat tilted at approximately a 50 angle as shown in DETAIL B. 3. The anchor must also be inserted at approximately a 20 angle from the rabbets of the frame as shown in DETAIL B. The flanges on the anchor must clear the backbend returns. 4. Twist the anchor into place by applying pressure in the opposite directions to each side of the anchor as shown in DETAIL C. 5. Once the anchor has snapped into place, DETAIL D, turn it up into the correct position as shown in DETAIL E legs should be bent back to the original position if necessary.
14 FRAME REINFORCEMENT 4-1/2" ULTIMA HINGE REINFORCEMENT DEFAULT REINFORCEMENT For All 4-1/2" Standard and Heavyweight Hinges.180" (4.6MM) To remove shim plate, insert flat screwdriver between shim and reinforcement, and pry shim away from reinforcement. NOTE: If shim is removed, prime paint hinge reinforcement. NOTE: Not recommended for conversion to electric hinge preparation.
15 FRAME REINFORCEMENT 5" HINGE REINFORCEMENT 5" HINGE REINFORCEMENT Drilled and Tapped Per Hinge Template STD Projections for Resistance Welding 1-5/8" (41.3) 9" (228.6) 5-9/16" (141.3) 7 GA. (4.5) Steel HEAVY 5" HINGE REINFORCEMENT NOTE: Electrical Hinge Preparation Available Per Template Drilled and Tapped Per Hinge Template STD Indicates Heavy Weight Hinge Reinforcement Projections for Resistance Welding 9" (228.6) 5-9/16" (141.3) 7 GA. (4.5) Steel
16 FRAME REINFORCEMENT CONTINUOUS HINGE REINFORCEMENT SURFACE MOUNTED CONCEALED MOUNTED 3/4" (19.1) 3/4" (19.1) 12 GA. (2.6) Reinforcing 12 GA. (2.6) Reinforcing 1/4" (6.4) 1/4" (6.4) NOTE: Hinge manufacturers recommend reinforcements on 20, 18, 16 gauge frames.
17 HOW TO ORDER METAL FRAMES ITEM ITEM DESCRIPTION This is for basic reference for product information and ordering, for detail description of product, see the product cut sheets. 1 FRAME INCLUDED? SPECIFY IF THE OPENING IS TO RECEIVE A FRAME SUPPLIED BY RITE DOOR Y Yes No 2 OPENING TYPE DETERMINES IF THE OPENING IS SINGLE, STANDARD PAIR OR DOUBLE EGRESS PAIR S Single Opening PR Standard Paired Opening UEP Unequal Standard Paired Opening DE Double Egress Opening UDE Unequal Double Egress Opening 3 FRAME PROFILE DETERMINES THE TYPE OF FRAME PROFILE TYPE YOU WANT FOR YOUR DOOR MK Masonry Face Flush KD Frame Cased Opening G Masonry Flush KD "G" Profile Frame DEM Masonry KD Double Egress Frame CUST Custom Frame Profile - Customer Defined M Masonry KD Face Flush Frame (Please see tech catalog for different M Profile Options N Nailer Frame (3 3/4-13 Jamb Depth) 4 CUSTOM FRAME DRAWING ELEV. USE ONLY IN THE EVENT THAT THE FRAME IS A CUSTOM FRAME PROFILE AND SIZE. (FRAME NEEDS TO BE QUOTED) 5 LABELED FRAME OPENING PLACE A Y TO INDICATE THAT THE FRAME IS TO BE RATED TO MATCH THE DOOR RATING 6 METAL GUAGE SPECIFY THE GAUGE OF STEEL THAT YOU WOULD LIKE Gauge Steel Gauge Steel - (Not available with CURRIEStain) 7 STEEL TYPE STEEL TYPE AS REQUESTED BY THE CUSTOMER CR Cold Rolled Steel RK Galvanized (A60 Standard) SS Stainless (304 #4 Satin finish - Quoted Only) LL-CR Lead Lined Frame- Cold Rolled (Quoted Only) LL-RK Lead Lined Frame- A60 Galvanized (Quoted Only) LL-SS Lead Lined Frame- Stainless Steel (Quoted Only * Please see the LEED Sell Sheet for details on LEED Qualifications for all RITE Door products.
18 HOW TO ORDER METAL FRAMES ITEM ITEM DESCRIPTION This is for basic reference for product information and ordering, for detail description of product, see the product cut sheets. 8 JAMB DEPTH (WHOLE INCHES) DETERMINS THE JAMB DEPTH NEEDED FOR THE FRAME (WHOLE INCHES) 9 JAMB DEPTH (FRACTIONS) DETERMINS THE JAMB DEPTH NEEDED FOR THE FRAME (FRACTIONS) 10 FINISH OPTION FOR THE FRAME PRIM Primed for field finish only. SS Stainless (304 #4 Satin finish - Quoted Only) 11 4 FRAME HEAD OPTION FRAME HEAD OPTION AVAILABLE Y Yes No 12 WELD CONSTRUCTION DETERMINES THE WELD TYPE OF THE FRAME KD Knock Down Frame - Not Welded SW Seam Weld - Face Welded Only FW Full Weld - Full Profile Weld 13 ANCHOR TYPE DETERMINES THE ANCHOR TYPE NEEDED FOR THE FRAME MW Masonry Wire Anchor EWA EWA - Anchor Type (Not Welded - Shipped Loose) WEWA EWA - Anchor Type (Welded into the Frame) WPS Pipe Spacer Anchor - Welded into the Frame WWS Wood Stud Anchor WSC Steel Stude channel Anchor MP Multipurpose Anchor - Anchor Ships Loose 14 # OF ANCHORS # OF ANCHORS WILL BE BASED ON THE OVERALL FRAME HEIGHT 6 Frame Height of 6'8" - 7'6" 8 Frame Height of 7'7" - 9'0" 10 Frame Height of 9'1" - 10'0" 15 STOP OPTION DETERMINE THE FRAME STOP OPTION HSP Hospital Stop Option - only available at this time * Please see the LEED Sell Sheet for details on LEED Qualifications for all RITE Door products.
19 HOW TO ORDER METAL FRAMES ITEM ITEM DESCRIPTION 16 SPECIAL INSTRUCTIONS This is for basic reference for product information and ordering, for detail description of product, see the product cut sheets. This is for any special instructions that are needed for the frame. Not all special instruction request can be accommodated, please contact factory to verify if request is available with RITE Door. You can also use this section to specify request for hardware that is not supplied, but will be a prep only LINE ITEM FRAME INCLUDED FRAME DETAIL OPENING TYPE FRAME PROFILE CUSTOM FRAME DRW LABELED FIRE RATED FRAME METAL GAGE STEEL TYPE JAMB DEPTH INCHES JAMB DEPTH FRAC FINISH 4" FRAME HEAD OPTION? WELD CONSTR ANCHOR TYPE # OF ANCHORS PER FRAME STOP OPTION SPECIAL INSTRUCTIONS: FRAMES: * Please see the LEED Sell Sheet for details on LEED Qualifications for all RITE Door products.
K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
INSTALLATION INSTRUCTIONS
door frames Engineered product systems INSTALLATION INSTRUCTIONS door frames MINIMALIST DOOR FRAME Fry Reglet Flush Door frames are designed for use with 3 5/8 studs with ½ drywall both sides (4 5/8 throat
BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
WHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
Steel Door Frame Installation in Steel Stud Construction
Steel Door Frame Installation in Steel Stud Construction For use with the Steel Door Institute (SDI) video How to Install a Steel Door Frames in Steel Stud Construction This manual gives you step-by-step
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Installation Instructions and Ordering Information
The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using
DISTRIBUTOR TECH DATA
Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data INDEX SECTION 11 - FRAMES, GENERAL Technical Information: Prime Paint Data.........................................................11-002
REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES
REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES Tools Required Tape Measure Hammer Slotted Screw Driver #2 & #3 Philips Screw Driver 3-4 Foot Level 12 Pry Bar Cold Chisel
WINDOW PANNING AND TRIMS
OCTOBER, 2010 PANNING AND TRIMS GENERAL INFORMATION 1 EXTERIOR PANNING Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows.
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art
D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries
Installation S D I 122-99 TECHNICAL DATA SERIES. and Troubleshooting Guide. for Standard Steel Doors and Frames STEEL DOOR INSTITUTE
TECHNICAL DATA SERIES S D I 122-99 Installation and Troubleshooting Guide for Standard Steel Doors and Frames STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Table of Contents Improper
Clad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
CRASH RAIL INSTALLATION HEIGHT
PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION OF THIS. CONTAINED
Technical Data Honeycomb Door Leaf 8-1-99
8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
Type 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
Doors and frames. Technical data manual 2015 rev. 8/17/15
Doors and frames Technical data manual 2015 rev. 8/17/15 Technical data manual Main table of contents NAVIGATE VIA: A) Rollover links in each TOC (each item below is a link), B) Bookmarks on the left,
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Hollow or Cinder Block Wall Mount Job Aid
Summary This Job Aid covers: Hollow or Cinder Block Wall Mount Job Aid Hollow or Cinder Block wall Mount Bracket Installing the Mount Bracket into Cinder Block This Job Aid supports the Technician audience.
MGB Chrome Bumper Conversion
MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different
n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame
Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22
Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows
Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Viewed from the exterior. IMPORTANT: Please read before you begin installation. TABLE OF CONTENTS AND TOOL / MATERIAL
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE
CONCEALED BEARING HINGES StANLEy ARCHItECtuRAL HARDwARE STANLEY ARCHITECTURAL HARDWARE TABLE OF CONTENTS Page Table of contents...2 Company history...2 5 knuckle concealed bearing design...3 Full mortise
Stainless Steel Continuous Hinges
Stainless Steel Continuous Hinges Hager heavy duty continuous hinges offer proven reliability that can stand up to the daily rigors of high-traffic, high-impact areas. They re designed and engineered to
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
Owner's Manual & Assembly Instructions
Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
Introduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
DOOR COMPONENTS, INC Technical Data
DOOR COMPONENTS, INC Technical Data DOOR COMPONENTS, INC 7980 Redwood Ave Fontana, CA 92336 Phone (909) 770 5700 Toll Free (866) 989 3667 Fax (909) 770 5722 www.doorcomponents.com INDEX FRAMES: PAGE #
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Ceiling Mounted Folding Attic Ladders Installation Instructions
Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:
Balance Shoe and Balance Replacement
and Replacement for E-Series Double-Hung and Single-Hung Windows Thank you for choosing Andersen. For questions call 1-888-888-7020. For more information and/or guides visit www.eaglewindow.com Please
Premier & Deluxe 3-Season Room Sliding Glass Door
DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen
FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 INSTALLATION INSTRUCTIONS FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 11/2 HOUR UL555 RATED UL555S LEAKAGE RATED
We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
Installation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
WINDOW REPAIR MANUAL & REFERENCE GUIDE
WINDOW REPAIR MANUAL & REFERENCE GUIDE TABLE OF CONTENTS DOUBLE HUNG & SINGLE HUNG PARTS 4-5 CASEMENT PARTS 6 SCREEN PARTS 7-8 HOW TO REMOVE TILT-IN SASH 9 HOW TO REMOVE A BALANCE 10 HOW TO INSTALL BALANCE
HOW TO INSTALL A BEAUTIFUL NEW KITCHEN
HOW TO INSTALL A BEAUTIFUL NEW KITCHEN Easy to follow step-by-step kitchen cabinet installation TOOL AND MATERIAL LIST Hammer Pry bar Screwdriver Phillips Flathead Level Tape measure Pencil Straight edge
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04
BROWN MINNEAPOLIS TANK PAGE 1 OF 7 PURPOSE: Create and Drawing Uniformity Create, explain, and establish a standard bill of materials to be placed on every drawing (except the overall tank elevation and
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
Wood Sound Retardant Door Hardware Information Bulletin
overly overly 574 West Otterman Street Greensburg, PA 15601 Toll Free: (800) 979-7300 Local: (724) 834-7300 Fax: (724) 830-2871 Email: [email protected] DOOR COMPANY Wood Sound Retardant Door Hardware
SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010
Best Barns USA Assembly Book Revised November 29, 2010 SAMPLE INSTRUCTIONS the Denver 12'x 12' or 12'x16' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775
Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille
Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille Text example Compile and tender according to requirements. Please refer to technical data below for respective
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
OVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.
Pick Smarter. Pick Better. Pick UNEX. Skatewheel (SW) Skatewheel Gravity Conveyor is ideally suited to convey lightweight packages and where operations require portable or temporary conveyor lines such
SUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
DIY CABINET REFACING INSTALLATION GUIDE
DIY CABINET REFACING INSTALLATION GUIDE CABINET REFACING INSTALLATION Are you ready to reface your outdated cabinets? This guide will show you how to install your new Facelifters Cabinet Refacing Products
Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors
Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...
Speed-Mat Rectangle Cutter
Speed-Mat Rectangle Cutter 1 Honeycomb baseboard. 2 Left hold down. 14 3 Bottom hold down. 4 4 Left / right rule. 8 5 8 5 Left / right rule pointer. 1 6 Top / bottom rule. 7 Top / bottom rule pointer.
Wisconsin Building Products Evaluation
Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation
Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW
Vinyl Windows and Doors Manufactured by Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Lea las instrucciones en español en el reverso.
Installation Guide for Andersen Architectural Wood Inswing Entry Doors
Installation Guide for Andersen Architectural Wood Inswing Entry Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Firewall Cover Installation Instruction Sheet
Firewall Cover Installation Instruction Sheet Please Read Carefully Our Firewall cover is designed to fit on the stock strut brace. If you have an aftermarket strut brace than it is you re responsibility
Installation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
SERIES 238 WINDOWS. NOTE: Read instructions completely before attempting any installation.
1 Installation Instructions SERIES 238 WINDOWS Page 2: Page 3-4: Page 5: Page 6: Page 7: Opening Preparation and Wood Buck Installation Installation Instructions for Series 238 WINDOWS Figure 1: Buck preparation
Sash Replacement Guide
for Andersen 200/400 Series Awning Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete this procedure, call Andersen at 1-888-888-7020
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray.
Casement/Awning Window Parts Reference Catalog
Casement/Awning Window Parts Reference Catalog (Includes Miscellaneous Parts for Eyebrow Casement and Garden Bay Windows) #1028654 (Revised 03/02) Weather Shield Mfg., Inc. Medford, WI 54451 715/748-2100
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
CNC Tool Storage Solutions
Solutions CNC TOOL STORAGE SOLUTIONS Thanks to the flexibility of the CNC line, your tools will be protected during regular handling, transportation and storage. The Rousseau CNC tool rack distinguishes
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA 810-09 METAL DOORS & FRAMES METAL. A Division of
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-09 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES HOLLOW METAL DOORS 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES A Division of HOLLOW METAL MANUFACTURERS A S S O C
AVENTOS HF Narrow aluminum door application
AVENTOS HF Narrow aluminum door application Lift mechanism set Lift mechanism (qty ) #7 x 35 mm (-3/8 ) wood screw (qty 0) Power factor 85 30 ( lift mechanism req.) 0F00.N5 3 470 0F00.N5 47 880 0F500.N5
INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg
Thank you for selecting JeLd-weN products. Attached are JeLd-weN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to
security products metric sizes Redefine your comfort zone. www.titus-hvac.com
metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table
HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 830-02 METAL S & FRAMES 8d NAAMM 01 02 HARDWARE SELECTION FOR HOLLOW METAL S AND FRAMES NAAMM 01 02 8d METAL S & FRAMES A Division of HOLLOW METAL MANUFACTURERS
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details
D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls
2. This is a close up of a typical area where the rocker is rusted out leaving holes under where the rocker moulding would be..
ROCKER PANELS 55,56,57 CHEVY REPLACEMENT Do not throw away any pieces when you first remove them. There are many supports that are not reproduced and will need to be used again. When disassembling try
How To Install Your Frameless Shower Enclosure
How To Install Your Frameless Shower Enclosure a) Installing Single Frameless Door Side Mounted Wall Hinges b) Installing Frameless Door with In-Line Panel c) Installing Frameless Door Between In-Line
Important Information for Installer & Homeowner
Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side
Retail Reception kiosk
Retail Reception kiosk put 42" corner post in below 66" to allow post to extend above kiosk for raised box sign Mini cantilever option - 24" overhead support leg Mini cantilever option - 24" overhead 66/48E
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
SSG PRODUCTS FOR SHIPS AND OFFSHORE
6.1 SSG PRODUCTS FOR SHIPS AND OFFSHORE SSG workshop cabinets, tables and shelving system specially adapted to be used on-board ships and offshore. Developed in close cooperation with users from these
Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE
Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)
Code No. LIT-1921710 Issued July 25, 2011 T-4000 Series Accessories Selection Chart T-4000 Series Accessories (Part 1 of 5) ( or Volume) F-100-20 F-300-30 F-300-34 F-300-31 F-300-35 F-500-45 F-300-30 Coupler,
UNIVERSAL ASSEMBLY INSTRUCTIONS FOR VERSATUBE BUILDINGS CONTRACTOR SERIES 2 X 4 FRAMES
UNIVERSAL ASSEMBLY INSTRUCTIONS FOR VERSATUBE BUILDINGS CONTRACTOR SERIES 2 X 4 FRAMES Our unique assembly process quickly transforms the individual pieces into a finished structure that will give you
CHALKBOARDS, MARKERBOARDS, TACKBOARDS, DISPLAY CASES, AND BULLETIN BOARD CABINETS
SECTION 10100 CHALKBOARDS, MARKERBOARDS, TACKBOARDS, DISPLAY CASES, AND BULLETIN BOARD CABINETS PART 1 GENERAL 1.01 SUBMITTALS A. Product Data: Submit copies of manufacturer's technical data and installation
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE