COMMERCIAL TYPE B GAS VENT MODEL E/V 10" 30"

Size: px
Start display at page:

Download "COMMERCIAL TYPE B GAS VENT MODEL E/V 10" 30""

Transcription

1 OMMERIL TYPE GS VENT MODEL E/V 10" 30" GS VENT 10" 30" EO INDEX DESRIPTION E/V PIPE ND FITTINGS 10" Model " Model " Model " Model " Model " Model " Model " Model " Model " Model " Model TEHNIL DT EO is proud to be a member of: SHRE merican Society of Heating, Refrigeration, and ir onditioning Engineers, Inc. HRI Heating, Refrigerating and ir onditioning Institute of anada HRDI Heating, irconditioning & Refrigeration Distributors International SMN SPID Sheet Metal & ir Spiral Duct onditioning ontractors Manufacturers National ssociation Inc. ssociation

2 EO ERTIFITION Listed by Underwriters Laboratories of anada, File Number MH 609. Listed by Underwriters Laboratories Inc., U.S.., File Number MH PPLITIONS EO Type Gas Vent is a prefabricated metal vent to be used for venting approved gas burning equipment as specified by the authorities having jurisdiction and not for incinerators or heating appliances requiring connection to chimneys. Temperatures at the outlet of the appliance draft hood shall not exceed 470 F (245 ). MTERILS The vent consists of factory made parts, designed to be assembled without requiring field fabrication. The inner conduit and Rain aps consist of an aluminum alloy of Type 1100 or Type The outer casing consists of Galvalume steel conforming to the latest revision of STM 792, Z150. Vent accessories consist of Galvanized steel conforming to the latest revision of STM 653. INSTLLTION GS VENT 10" 30" Every 30 feet of vent height requires at least one Support Plate and Ring ssembly. The vent shall extend at least 2 feet above the highest point where it passes through a flat roof and at least 2 feet higher than any part of the building within a horizontal distance of 10 feet. The vent shall extend at least 2 feet above the highest point where it passes through a pitch roof of 9/12 pitch or less and at least 2 feet higher than any other obstruction within a horizontal distance of 10 feet. learance to combustible materials shall not be less than 1 inch. Except for installation in single and two family dwellings, gas vents which extend through any storey above that on which the connected appliance is located are to be provided with enclosures having a fire resistance rating equal to, or greater than, that of the floor or roof assemblies through which they pass. To ensure a safe and proper installation, install the vent using all the parts as specified in the Installation Instructions. ird screens may be susceptible to blockage through freezing moisture in areas of low ambient temperature. onsult authority having jurisdiction. DIE-FORMED OUPLINGS integrates the inner and outer pipe as one unit ensures consistent quality and fit OUTSIDE SING OF GLVLUME OR GLVNIZED STEEL provides strength and durability PRESTMPED SREW HOLES no drilling easy and quick assembly a positive and strong lock 1" INSULTING IR SPE eliminates condensation, while keeping the outer casing cool INSIDE ONDUIT OF LUMINUM resists corrosion 90

3 10" MODEL E/V TYPE GS VENT PIPE ND FITTINGS GS VENT 10" 30" EO STOK # MODEL DESRIPTION WT/100 PRIE/E VP 10" 12" -Vent Pipe 400 $ VP 10" 18" -Vent Pipe VP 10" 24" -Vent Pipe VP 10" 36" -Vent Pipe VP 10" 60" -Vent Pipe VP 10" 18" -Vent Pipe djustable R 10" Rain ap S 10" Storm ollar F 10" djustable Flashing /12 7/12 Pitch FF 10" Flat Flashing FS 10" Fire Stop Spacer SWT 10" 10" 10" Single Wall Tee DWT 10" 10" 10" Double Wall Tee DWW 10" 10" 10" Double Wall Wye PT 10" Plug/Tee ap Spun Galvanized EL 10" 45 Double Wall Elbow EL 10" 90 Double Wall Elbow DH 10" Draft Hood onnector SP 10" Support Plate SR 10" Support Ring For Technical Data see end of section. 12" MODEL E/V TYPE GS VENT PIPE ND FITTINGS STOK # MODEL DESRIPTION WT/100 PRIE/E VP 12" 12" -Vent Pipe 490 $ VP 12" 18" -Vent Pipe VP 12" 24" -Vent Pipe VP 12" 36" -Vent Pipe VP 12" 18" -Vent Pipe djustable R 12" Rain ap S 12" Storm ollar F 12" djustable Flashing /12 7/12 Pitch FF 12" Flat Flashing FS 12" Fire Stop Spacer SWT 12" 12" 12" Single Wall Tee DWT 12" 12" 12" Double Wall Tee (cont d on next page) Type Gas Vent Pipe and Fittings 91

4 EO GS VENT 10" 30" 12" MODEL E/V TYPE GS VENT PIPE ND FITTINGS (cont d) STOK # MODEL DESRIPTION WT/100 PRIE/E PT 12" Plug/Tee ap Spun 140 $ Galvanized EL 12" 45 Double Wall Elbow EL 12" 90 Double Wall Elbow DH 12" Draft Hood onnector SP 12" Support Plate SR 12" Support Ring ustom -Vent available upon request. For Technical Data see end of section. 14" MODEL E/V TYPE GS VENT PIPE ND FITTINGS STOK # MODEL DESRIPTION WT/100 PRIE/E Type Gas Vent Pipe and Fittings VP 14" 12" -Vent Pipe 570 $ VP 14" 18" -Vent Pipe VP 14" 24" -Vent Pipe VP 14" 36" -Vent Pipe VP 14" 18" -Vent Pipe djustable R 14" Rain ap S 14" Storm ollar F 14" djustable Flashing /12 7/12 Pitch FF 14" Flat Flashing FS 14" Fire Stop Spacer SWT 14" 14" 14" Single Wall Tee DWT 14" 14" 14" Double Wall Tee PT 14" Plug/Tee ap Spun Galvanized EL 14" 45 Double Wall Elbow DH 14" Draft Hood onnector SP 14" Support Plate SR 14" Support Ring For Technical Data see end of section. 92

5 16" MODEL E/V TYPE GS VENT PIPE ND FITTINGS GS VENT 10" 30" EO STOK # MODEL DESRIPTION WT/100 PRIE/E VP 16" 12" -Vent Pipe 650 $ VP 16" 18" -Vent Pipe VP 16" 24" -Vent Pipe VP 16" 36" -Vent Pipe VP 16" 18" -Vent Pipe djustable R 16" Rain ap S 16" Storm ollar F 16" djustable Flashing /12 7/12 Pitch FF 16" Flat Flashing FS 16" Fire Stop Spacer SWT 16" 16" 16" Single Wall Tee DWT 16" 16" 16" Double Wall Tee PT 16" Plug/Tee ap Spun Galvanized EL 16" 45 Double Wall Elbow DH 16" Draft Hood onnector SP 16" Support Plate SR 16" Support Ring For Technical Data see end of section. 18" MODEL E/V TYPE GS VENT PIPE ND FITTINGS STOK # MODEL DESRIPTION WT/100 PRIE/E VP 18" 12" -Vent Pipe 720 $ VP 18" 18" -Vent Pipe VP 18" 24" -Vent Pipe VP 18" 36" -Vent Pipe VP 18" 18" -Vent Pipe djustable R 18" Rain ap S 18" Storm ollar F 18" djustable Flashing /12 7/12 Pitch FF 18" Flat Flashing FS 18" Fire Stop Spacer SWT 18" 18" 18" Single Wall Tee DWT 18" 18" 18" Double Wall Tee PT 18" Plug/Tee ap Spun Galvanized EL 18" 45 Double Wall Elbow DH 18" Draft Hood onnector SP 18" Support Plate SR 18" Support Ring Type Gas Vent Pipe and Fittings For Technical Data see end of section. 93

6 EO GS VENT 10" 30" 20" MODEL E/V TYPE GS VENT PIPE ND FITTINGS STOK # MODEL DESRIPTION WT/100 PRIE/E VP 20" 12" -Vent Pipe 770 $ VP 20" 18" -Vent Pipe VP 20" 24" -Vent Pipe VP 20" 36" -Vent Pipe VP 20" 18" -Vent Pipe djustable R 20" Rain ap S 20" Storm ollar F 20" djustable Flashing /12 7/12 Pitc FF 20" Flat Flashing FS 20" Fire Stop Spacer SWT 20" 20" 20" Single Wall Tee DWT 20" 20" 20" Double Wall Tee PT 20" Plug/Tee ap Spun Galvanized EL 20" 45 Double Wall Elbow DH 20" Draft Hood onnector SP 20" Support Plate SR 20" Support Ring For Technical Data see end of section. 22" MODEL E/V TYPE GS VENT PIPE ND FITTINGS Type Gas Vent Pipe and Fittings STOK # MODEL DESRIPTION WT/100 PRIE/E VP 22" 12" -Vent Pipe 870 $ VP 22" 18" -Vent Pipe VP 22" 24" -Vent Pipe VP 22" 36" -Vent Pipe VP 22" 24" -Vent Pipe djustable R 22" Rain ap S 22" Storm ollar F 22" djustable Flashing /12 7/12 Pitch FF 22" Flat Flashing FS 22" Fire Stop Spacer SWT 22" 22" 22" Single Wall Tee DWT 22" 22" 22" Double Wall Tee PT 22" Plug/Tee ap Spun Galvanized EL 22" 45 Double Wall Elbow DH 22" Draft Hood onnector SP 22" Support Plate SR 22" Support Ring For Technical Data see end of section. 94

7 24" MODEL E/V TYPE GS VENT PIPE ND FITTINGS GS VENT 10" 30" EO STOK # MODEL DESRIPTION WT/100 PRIE/E VP 24" 12" -Vent Pipe 940 $ VP 24" 18" -Vent Pipe VP 24" 24" -Vent Pipe VP 24" 36" -Vent Pipe VP 24" 18" -Vent Pipe djustable R 24" Rain ap S 24" Storm ollar F 24" djustable Flashing /12 7/12 Pitch FF 24" Flat Flashing FS 24" Fire Stop Spacer SWT 24" 24" 24" Single Wall Tee DWT 24" 24" 24" Double Wall Tee PT 24" Plug/Tee ap Spun Galvanized EL 24" 45 Double Wall Elbow DH 24" Draft Hood onnector SP 24" Support Plate SR 24" Support Ring For Technical Data see send of section. 26" MODEL E/V TYPE GS VENT PIPE ND FITTINGS STOK # MODEL DESRIPTION WT/100 PRIE/E VP 26" 18" -Vent Pipe 1830 $ VP 26" 24" -Vent Pipe VP 26" 36" -Vent Pipe VP 26" 18" -Vent Pipe djustable R 26" Rain ap , S 26" Storm ollar FF 26" Flat Flashing FS 26" Fire Stop Spacer DWT 26" 26" 26" Double Wall Tee PT 26" Plug/Tee ap Galvanized EL 26" 45 Double Wall Elbow , DH 26" Draft Hood onnector S 26" Support ssembly Type Gas Vent Pipe and Fittings For Technical Data see end of section. 95

8 EO GS VENT 10" 30" 28" MODEL E/V TYPE GS VENT PIPE ND FITTINGS STOK # MODEL DESRIPTION WT/100 PRIE/E VP 28" 18" -Vent Pipe 1900 $ VP 28" 24" -Vent Pipe VP 28" 36" -Vent Pipe VP 28" 18 -Vent Pipe djustable R 28" Rain ap , S 28" Storm ollar FF 28" Flat Flashing FS 28" Fire Stop Spacer DWT 28" 28" 28" Double Wall Tee PT 28" Plug/Tee ap Galvanized EL 28" 45 Double Wall Elbow , DH 28" Draft Hood onnector S 28" Support ssembly For Technical Data see end of section. 30" MODEL E/V TYPE GS VENT PIPE ND FITTINGS Type Gas Vent Pipe and Fittings STOK # MODEL DESRIPTION WT/100 PRIE/E VP 30" 18" -Vent Pipe 2040 $ VP 30" 24" -Vent Pipe VP 30" 36" -Vent Pipe VP 30" 18 -Vent Pipe , djustable R 30" Rain ap , S 30" Storm ollar FF 30" Flat Flashing FS 30" Fire Stop Spacer DWT 30" 30" 30" Double Wall Tee , PT 30" Plug/Tee ap Galvanized EL 30" 45 Double Wall Elbow , DH 30" Draft Hood onnector S 30" Support ssembly For Technical Data see end of section. 96

9 TEHNIL DT MODEL E/V 10" 24" Vent Pipe VP LENGTH 60" 36" 24" 18" 12" SIZE (") (") (") (") (") (") (") /4 34-3/4 22-3/4 16-3/4 10-3/ N/ 34-3/4 22-3/4 16-3/4 10-3/ N/ 34-3/4 22-3/4 16-3/4 10-3/ N/ 34-3/4 22-3/4 16-3/4 10-3/ N/ 34-3/4 22-3/4 16-3/4 10-3/ N/ 34-3/4 22-3/4 16-3/4 10-3/ N/ 34-3/4 22-3/4 16-3/4 10-3/ N/ 34-3/4 22-3/4 16-3/4 10-3/4 GS VENT 10" 30" EO Dimension is installed length. Vent Pipe djustable VP SIZE (") (") (") djusts from 4" to 16" Rain ap R SIZE (") (") (") / / / / /4 43 SIZES 10" 12" SIZES 14" 24" 97

10 EO TEHNIL DT MODEL E/V 10" 24" (cont d) Storm ollar S GS VENT 10" 30" SIZE (") (") (") / / / / / / / /4 26 djustable Roof Flashing 1/12 7/12 Pitch F SIZE (") (") (") (") D (") / / / / /4 5 Flat Roof Flashing FF SIZE (") (") (") (") D (") / / / /4 10 ll seams are soldered. 98

11 GS VENT 10" 30" TEHNIL DT MODEL E/V 10" 24" (cont d) EO Fire Stop Spacer FS SIZE (") (") (") (") Fire Stop Spacers are required above and below each floor and ceiling level penetrated by the vent. Support Plate SP SIZE (") (") (") (") D (") D Support Plate and Support Ring are required for every 30 feet of vent height. Support Ring SR SIZE (") (") (") Includes Sheet Metal Screws and ssembly olt for installation. Support Plate and Support Ring are required for every 30 feet of vent height. 99

12 EO TEHNIL DT MODEL E/V 10" 24" (cont d) 45 Elbow 45EL GS VENT 10" 30" SIZE (") (") (") D (") E (") /8 3-1/ /8 4-1/4 3-1/ /8 4-5/8 3-1/ /4 5-1/8 3-1/ /8 5-1/2 3-1/ /8 3-1/ /2 6-3/8 3-1/ /8 6-3/4 3-1/2 D E Offset SIZE (") (") (") /4 15-1/ /8 16-1/ / / /8 20-3/ /4 22-1/ /4 23-5/ / Elbow 90EL SIZE (") (") (") D (") /4 11-1/ /4 11-3/ /8 13-1/ /8 14-1/ /8 15-1/ /8 16-1/ /8 17-1/ /8 18-1/4 For sizes 14" 24" use two 45 Elbows to make

13 GS VENT 10" 30" TEHNIL DT MODEL E/V 10" 24" (cont d) EO Double Wall Tee DWT SIZE (") (") (") D (") E (") / / /4 12-1/ /4 13-1/ /4 14-1/ /4 15-1/ /4 16-1/ /4 17-1/2 17 E D Dimension is installed length. Stub Dimension may vary according to customer requirements. Tee ap not included. Double Wall Wye DWW SIZE (") (") (") D (") Dimensions and D may vary according to customer requirements. Double Wall Increaser IN SIZE (") (") (") D (") / / / / / / / /2 Includes Sheet Metal Screws for installation. Dimensions and D may vary according to customer requirements

14 EO TEHNIL DT MODEL E/V 10" 24" (cont d) Draft Hood onnector DH SIZE (") (") (") D (") / / / / / / / /2 GS VENT 10" 30" Single Wall ase Tee SWT SIZE (") (") (") D (") E (") / / / /4 11-1/ /4 12-1/ /4 13-1/ /4 14-1/ /4 15-1/ /4 16-1/2 16 Factory installed Tee ap attached to bottom of Tee. Stub dimension may vary according to customer requirements. Spun Tee ap T SIZE (") (") / / / / / / / /

15 TEHNIL DT MODEL E/V 26" 30" Vent Pipe VP LENGTH 36" 24" 18" SIZE (") (") (") (") (") Dimension is installed length. Rain ap R SIZE (") (") (") / / /2 53 GS VENT 10" 30" 3/8" ead EO Storm ollar S SIZE (") (") (") / / /4 32 Includes ssembly olts for installation. Flat Roof Flashing FF SIZE (") (") (") (") D (") / / /2 ll Flat Flashings are soldered. djustable flashing available on request. Fire Stop Spacer FS SIZE (") (") (") (") / / / Fire Stop spacers are required above and below each floor and ceiling level penetrated by the vent

16 EO TEHNIL DT MODEL E/V 26" 30" (cont d) Support ssembly S SIZE (") (") (") GS VENT 10" 30" Includes Sheet Metal Screws and ssembly olt for installation. Required for every 30 feet of vent height. 45 Elbow 45EL D SIZE (") (") (") D (") E (") /8 7-1/8 3-1/ /4 7-5/8 3-1/ / /2 E Double Wall Tee DWT SIZE (") (") (") D (") E (") / / /4 Dimension is installed length. Dimension may vary according to customer requirements. Tee ap not included. D E Draft Hood onnector DH SIZE (") (") (") D (") / / /2 Tee ap T SIZE (") (")

Installation Instructions. Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect

Installation Instructions. Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect Installation Instructions Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

Type B Gas Vent. Type B Gas Vent. DuraFlex AL. Type B gas venting system. UL 441 and ULC S605. Aluminum flexible relining UL 1777 & ULC S635.

Type B Gas Vent. Type B Gas Vent. DuraFlex AL. Type B gas venting system. UL 441 and ULC S605. Aluminum flexible relining UL 1777 & ULC S635. Type Gas Vent Type Gas Vent Type gas venting system. UL 441 and ULC S605. DuraFlex L luminum flexible relining UL 1777 & ULC S635. Specifications pplications DuraVent s Type Gas Vent system. Use with natural

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

Diagnostics for Mobile Homes: HVAC

Diagnostics for Mobile Homes: HVAC Diagnostics for Mobile Homes: HVAC Adam Harris NYSWDA Wade Thompson - IWTC Objectives Identify different types of HVAC used in mobile homes Provide an overview of duct systems Demonstrate various tests

More information

ASX7-4-IOM-7 J30-08579

ASX7-4-IOM-7 J30-08579 INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT

More information

Type L Vent Installation Instructions

Type L Vent Installation Instructions Type L Vent Installation Instructions UL 641 Listed General Information AirJet L Vent is listed for use with modern high-efficiency oil or gas fired appliances with operating fl ue temperatures up to 570

More information

CHAPTER 5 WATER HEATERS

CHAPTER 5 WATER HEATERS PlumbingCode06_ch05 5/29/06 8:12 AM Page 1 CHAPTER 5 WATER HEATERS Water heaters are only a small portion of a plumbing system, but they are important, and they can be dangerous. Many plumbers take water

More information

Arapahoe County Residential Water Heater Installation and Inspection Guide

Arapahoe County Residential Water Heater Installation and Inspection Guide Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here. COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

Flue Installation. High Efficiency Condensing Boilers

Flue Installation. High Efficiency Condensing Boilers Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION

More information

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR Water Heaters Residential gas water heaters Selection Guide To select the right State water heater for a home, you need to consider the size of the family and other factors that contribute to the Peak

More information

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting ING THE WATER HEATER The purpose of venting a gas or oil-fired water heater is to completely remove all products of combustion and to vent gasses to the outside air without condensation in the vent or

More information

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

Installation Instructions

Installation Instructions Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email [email protected] Phone:

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

Exhaust Calculation Booklet

Exhaust Calculation Booklet Exhaust Calculation Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: [email protected] ADC Part No. 450450 Exhaust

More information

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.

More information

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers.. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by

More information

HVAC Code Requirements

HVAC Code Requirements one and two family dwellings? Answer: SECTION 2001: GENERAL 2001.1 Air supply. Fuel-burning equipment shall be provided with a supply of air for fuel combustion, draft hood dilution and ventilation of

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000 Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,

More information

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer

More information

HV AC CODE CHECKLISTS

HV AC CODE CHECKLISTS The following text is informational only and shall serve as an informational guide for HV AC contractors, journeymen, and apprentices working in the Heating, Ventilation, and Air Conditioning industry.

More information

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the

More information

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic Test Room ID: R21F Description: SEMI ANECHOIC SHIELDED TEST ENCLOSURE Primary Testing Uses: FCC, CE Mark Dimensions: 9.75m x 6.10m x 5.49m (32ft. x 20ft. x 18ft.) [see Figure 3 below] Construction: Galvanized

More information

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This

More information

SPEC AMERICAN. SPEC BRIDGEPORT.

SPEC AMERICAN. SPEC BRIDGEPORT. SPE MERIN. SPE RIDGEPORT. ridgeport Zinc or Steel Meets: UL514 Specifications: --50552 Fittings for able and Flexible Metal onduit --50553 Fittings for Rigid and EMT onduit --50563 onduit Outlet oxes,

More information

System Report SR-405B DECEMBER 2014

System Report SR-405B DECEMBER 2014 System Report SR-405 EEMER 2014 Fire Protection of Floors onstructed with Prefabricated Wood I-Joists for ompliance with the International Residential ode 1. SIS OF THE SYSTEM REPT n 2015 International

More information

DRYER VENTING SPECIFICATIONS DRYER SAFETY

DRYER VENTING SPECIFICATIONS DRYER SAFETY DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting

More information

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL Boiler Manual A. INSTALLING EXHAUST VENT AND INTAKE AIR VENT B. GENERAL n DANGER The Elite Heating Boiler must be vented as detailed in this section.

More information

A GUIDE TO SAFER GAS FLUEING

A GUIDE TO SAFER GAS FLUEING A GUIDE TO SAFER GAS FLUEING PUBLISHED BY ABEY, OFFICE OF GAS SAFETY AND THE PLUMBING INDUSTRY COMMISSION CONTENTS THE PURPOSE OF GAS APPLIANCE FLUEING Simplified theory of flueing principles of twin skin

More information

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain

More information

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since

More information

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary. INSTALLATION, OPERATING AND SERVICE MANUAL FOR EASY RADIANT WORKS HEATWAVE MODEL GH-25-40 GAS FIRED, VENTED INFRARED TUBE HEATER FOR RESIDENTIAL & COMMERCIAL / INDUSTRIAL APPLICATIONS. For Your Safety

More information

Building Code Clarifications - 7. Fire Resistance

Building Code Clarifications - 7. Fire Resistance Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional

More information

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description Worldwide Contacts www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description TYCO Series DS-1 Dry-Type Sprinklers, 5.6

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

FINAL December 2012 SECTION 233100 DUCTWORK

FINAL December 2012 SECTION 233100 DUCTWORK SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insula tion shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors. September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify

More information

Preventing Ice Dams on Roofs

Preventing Ice Dams on Roofs Preventing Ice Dams on Roofs Facility Manager November/December 2005 When a roof leaks, facility managers inevitably receive complaints from building occupants. If it is winter, ice dams are often the

More information

Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY

Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY Purpose and Intended Audience The August 24, 2014 South Napa Earthquake has again served as a reminder that

More information

Contents and Nomenclature

Contents and Nomenclature DX Coils Contents and Nomenclature Nomenclature... 1 Evaporator Coil Types EN... 2 EF... 2 ER... 2 EJ... 3 EK... 3 Evaporator Construction Connections... 4 Tubing... 4 Headers... 5 Tube Supports... 5 Coil

More information

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

TABLE OF CONTENTS SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7 2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

Installation Instructions

Installation Instructions VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling

More information

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES 4121 N.W. 37 th Street, Lincoln, NE 68524 Telephone (402) 470-2627 Fax (404) 470-2410 www.gtexhaust.com

More information

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant

More information

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES INDEX ALLIGATOR CLIPS... 7-7 compressor lead sets... 7-7 CONNECTORS BUTT... 7-3 closed... 7-3 ELECTRICAL... 7-2 terminal adapters... 7-2 QUICK CONNECTS... 7-5 7-6 TWIST-ON WIRE... 7-2 HEAT SHRINK TUBING

More information

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options

More information

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS International Code Council National Fire Protection Association Underwriters Laboratories Inc. 5203 Leesburg Pike, Suite 600 1 Batterymarch

More information

Fire Barrier Duct Wrap 15A

Fire Barrier Duct Wrap 15A 3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies

More information

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition. DIVISION 15 MECHANICAL SECTION 15100 - PLUMBING PART 1 - GENERAL SCOPE Plumbing work includes all domestic water, gas, and sanitary sewer systems as shown on plans. Also all fixtures and equipment which

More information

Specifications for Lightning Protection. ASAE Engineering Practice

Specifications for Lightning Protection. ASAE Engineering Practice Chapter 8: Lightning Specifications for Lightning Protection ASAE safety standards are not laws. They are recommended voluntary standards used by designers, engineers, manufacturers and users of the equipment,

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Fabricated Drainage Products

Fabricated Drainage Products Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

The Perfect Fit For Metal Retrofit

The Perfect Fit For Metal Retrofit D u r o - S h i e l d M e t a l R e t r o f i t R o o f i n g S y s t e m The Perfect Fit For Metal Retrofit Lock out leaks. Lock in your investment. Has time caught up with your metal roof? There are

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

CB29M Bulletin #490071 February 1996

CB29M Bulletin #490071 February 1996 ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating

More information

city of edmonds development information

city of edmonds development information #B17 city of edmonds development information Commercial Kitchen Hood & Hood Fire Suppression System Permit Submittal Requirements PERMIT REQUIRED: CODES: FEES: A Commercial Kitchen Hood Mechanical Permit

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

Fundamentals of Venting and Ventilation

Fundamentals of Venting and Ventilation Fundamentals of Venting and Ventilation Vent System Operation Sizing, Design and Applications Installation and Assembly Troubleshooting American Standard Inc. 1993 Pub. No. 34-41-2 Contents Subject Page

More information

Chimneys in Thatched Properties

Chimneys in Thatched Properties Chimneys in Thatched Properties Compliance with Building Regulations when installing or repairing a chimney or re-thatching a roof that abuts a chimney The increasing problem of thatch fires Over the last

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

Residential Roofing Guide

Residential Roofing Guide Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 ) Natural Gas Appliance Testing Action Guidelines (n ESA/Low Income 5 ) The purpose of these Action Guidelines is to describe the actions participating contractors and/or inspectors should take in the event

More information

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

Top 10+ Mistakes of DWV plumbing design

Top 10+ Mistakes of DWV plumbing design Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Requirements for Electrical Installations

Requirements for Electrical Installations ARTICLE 110 Requirements for Electrical Installations INTRODUCTION TO ARTICLE 110 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS Article 110 sets the stage for how you ll implement the rest of the NEC. This

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715, 4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.

More information

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809

More information