1 , Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1(C) (B) (-1; -3) db U-value (EN 673) 2,8 W / (m 2 K) Light transmission and reflection 0,58/0,10/0,13 Solar energy characteristics 0,40/0,08/0,10 : No Performance Determined

2 , Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1(C) (B) (-1; -3) db U-value (EN 673) 2,7 W / (m 2 K) Light transmission and reflection 0,58/0,10/0,13 Solar energy characteristics 0,40/0,08/0,10 : No Performance Determined

3 , Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1 (C) (B) U-value (EN 673) 2,8 W / (m 2 K) Light transmission and reflection 0,49/0,09/0,13 Solar energy characteristics 0,33/0,/0,10 : No Performance Determined

4 , Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1 (C) (B) U-value (EN 673) 2,7 W / (m 2 K) Light transmission and reflection 0,49/0,09/0,13 Solar energy characteristics 0,33/0,/0,10 : No Performance Determined

5 , Thermally Toughened Helio Blue + Dry Air (%100) P1A Pendulum body impact resistance 1 (C) (B) U-value (EN 673) 2,8 W / (m 2 K) Light transmission and reflection 0,49/0,09/0,13 Solar energy characteristics 0,33/0,/0,09 : No Performance Determined

6 , Thermally Toughened Helio Blue + Dry Air (%100) P1A Pendulum body impact resistance 1 (C) (B) U-value (EN 673) 2,7 W / (m 2 K) Light transmission and reflection 0,49/0,09/0,13 Solar energy characteristics 0,33/0,/0,09 : No Performance Determined

7 , Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1 (C) (B) U-value (EN 673) 2,8 W / (m 2 K) Light transmission and reflection 0,42/0,/0,12 Solar energy characteristics 0,26/0,06/0,09 : No Performance Determined

8 , Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1 (C) (B) U-value (EN 673) 2,7 W / (m 2 K) Light transmission and reflection 0,42/0,/0,12 Solar energy characteristics 0,26/0,06/0,09 : No Performance Determined

9 , Thermally Toughened Helio Blue + Dry Air (%100) P1A Pendulum body impact resistance 1 (C) (B) U-value (EN 673) 2,8 W / (m 2 K) Light transmission and reflection 0,42/0,/0,12 Solar energy characteristics 0,27/0,06/0,09 : No Performance Determined

10 , Thermally Toughened Helio Blue + Dry Air (%100) P1A Pendulum body impact resistance 1 (C) (B) U-value (EN 673) 2,7 W / (m 2 K) Light transmission and reflection 0,42/0,/0,12 Solar energy characteristics 0,27/0,06/0,09 : No Performance Determined

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4-12 - 4 (#3), Thermally Toughened Helio Blue + Dry Air (100%) + 1(C)3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,58/0,/0,10 Solar energy characteristics

More information

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5 4 (#2) - 12-4, Thermally Toughened ISS114 #2 + Dry Air (%100) + Clear 1(C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 2,6 W / (m 2 K) Light transmission and reflection 0,14/0,34/0,37 Solar energy

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 6 (#1) - 12-4 (#3), Thermally Toughened Tentesol T Blue #1 + Dry 1(C)2-12 - 6-12 - 4 32 (-2; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,34/0,34/0,18 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Thermally Toughened Heat and Solar Control Glass 1 (C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics

More information

EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)

EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356) 4 (# 2) - 12-33.1, Heat Control Glass (Low-E #2) + Argon (90%) + Pendulum body impact resistance - 12-2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Argon (90%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4-12 - 4 (#3), Clear Float Glass + Argon (90%) +Heat Control Glass 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

CE Marking of Glass products

CE Marking of Glass products CE Marking of Glass products INTRODUCTION... 10 ARTLITE... 11 ARTLITE / ARTLITE DIGITAL HEAT STRENGTHENED... 12 ARTLITE / ARTLITE DIGITAL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 1 ARTLITE

More information

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the

More information

Unbeatable energy efficient glass curtain wall system

Unbeatable energy efficient glass curtain wall system Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics

More information

NATURAL STONE LABORATORY

NATURAL STONE LABORATORY Price List 2.015 Rev.3 Sheet 1 of 5 Natural stone: PN001 Petrographic examination EN 12407:2007 185,00 PN002A Geometric characteristics EN 13373:2003 18,00 PN003 Water absorption at atmospheric pressure

More information

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature

More information

LBNL WINDOW 6 AND OPTICS 6 PROCEDURES TO COMPUTE THE SOLAR / OPTICAL PERFORMANCE OF NEW PRODUCTS AND LAMINATED GLASS

LBNL WINDOW 6 AND OPTICS 6 PROCEDURES TO COMPUTE THE SOLAR / OPTICAL PERFORMANCE OF NEW PRODUCTS AND LAMINATED GLASS Technical Bulletin ATS-171 TO COMPUTE THE SOLAR / OPTICAL PERFORMANCE OF NEW PRODUCTS AND LAMINATED GLASS Notes on Window and Optics 6 Programs Window 6 and Optics 6 programs are available free from LBNL

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001 NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001 NO. HU-DOP_TD-25_001 Product type TD 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-35_001 Product type TD 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-45_001 Product type TD 3,5x45 mm EN 14566:2008+A1:2009

More information

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency

More information

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Self-cleaning Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories

More information

SELECTIVE GLAZING FOR SUN CONTROL

SELECTIVE GLAZING FOR SUN CONTROL SUN CONTROL GLAZING SELECTIVE GLAZING FOR SUN CONTROL Sun Factor 1st level performance for direct solar energy Solar energy control Solar control coating Only if the glass is exposed to sun rays! 2nd level

More information

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31. Uniclass L411 +L413:P7114 EPIC D11 +D13:X725 CI/SfB (31.4)+(31.5) Xn6 9/11 SmartSash A BRAND OF THE VEKA UK GROUP Specification Guide Fenestration Solutions for Public Sector & Commercial Applications

More information

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Pilkington Activ The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Thermal insulation. When it comes to conservatories, we think

More information

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Self-Cleaning The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Conservatories bringing the outside in. Pilkington Activ has made

More information

Solar control right for you!

Solar control right for you! Solar control right for you! Landesbank Baden-Württemberg, Stuttgart SGG COOL-LITE ST 0 SGG COOL-LITE ST Solar control right for you! D e s c r i p t i o n SGG COOL-LITE ST is a solar control glass manufactured

More information

Series 456 Commercial Awning Window

Series 456 Commercial Awning Window Commercial Awning Window COMMERCIAL SERIES Photo courtesy of Hanlon Windows Australia DATE: MAY 2013 REPLACES: MARCH 2008 COMMERCIAL SERIES KEY FEATURES/PERFORMANCE CHARACTERISTICS Scale: not to scale

More information

ENVIRONMENTAL TESTING SERVICES. Product and component performance verification

ENVIRONMENTAL TESTING SERVICES. Product and component performance verification ENVIRONMENTAL TESTING SERVICES Product and component performance verification environmental testing State-of-the-art technology and increased demands for product and component reliability have intensified

More information

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Pilkington Activ self-cleaning glass. The clear choice for your conservatory. The Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories bringing

More information

THE REYNAERS INSTITUTE

THE REYNAERS INSTITUTE THE REYNAERS INSTITUTE TOGETHER FOR BETTER INTRODUCTION Since the company s creation in 1965, Reynaers Aluminium has been playing a leading role in the construction industry. Its profile systems have evolved

More information

ENERGY LABELLING OF GLAZINGS AND WINDOWS IN DENMARK: CALCULATED AND MEASURED VALUES

ENERGY LABELLING OF GLAZINGS AND WINDOWS IN DENMARK: CALCULATED AND MEASURED VALUES Pergamon P II: S0038 09X(0)00031 Solar Energy Vol. 73, No. 1, pp. 3 31, 00 00 Elsevier Science Ltd All rights reserved. Printed in Great Britain 0038-09X/0/$ - see front matter www.elsevier.com/ locate/

More information

Building Standards Conservatory Roofs Meeting 28 Nov 2012

Building Standards Conservatory Roofs Meeting 28 Nov 2012 Conservatory Roofs Meeting 28 Nov 2012 Reason for hosting this meeting Availability of new roofing systems Increasing popularity in changing from transparent to opaque roof finishes Lack of clarity and

More information

Windows are one of the most important components of a

Windows are one of the most important components of a design concepts Arjun Kamal MAKING BETTER INDOOR ENVIRONMENTS WITH ENERGY-EFFICIENT WINDOW DESIGN An insight into the various technologies used for constructing windows, and an attempt at understanding

More information

THERMAL CHARACTERISTICS Nominal operating cell temperature(noct) [ C] 48,2±2 48 Temperature coefficient P MPP [%K] -0,41-0,47 Temperature coefficient I SC [%K] 0,05 0,04 Temperature coefficient U OC [%K]

More information

DOMUS & ALDUS THE WINDOW CONCEPT WITH A STUNNINGLY MODERN APPEARANCE

DOMUS & ALDUS THE WINDOW CONCEPT WITH A STUNNINGLY MODERN APPEARANCE DOMUS & ALDUS THE WINDOW CONCEPT WITH A STUNNINGLY MODERN APPEARANCE MODERN DESIGN DOMUS & ALDUS 2 3 ALDUS & DOMUS PRODUCT DETAILS 1 2 3 Option of glazing bar Architectural designed handle Option of trickle

More information

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace HEAT GAINS and LOSSES : ROOFS and WALLS Wall Roof Ts To Ts To Ti Ceiling/Airspace Ti Roof and wall are analyzed in the same way. In winter the heat loss is simple transmission based on the inside and outside

More information

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector NOW AVAILABLE! the new ASW-58A-22/30 Solar Thermal Collector The ASW-58A-22/30 series of collectors are available in 22 and 30 tube units. Other sizes are available upon request. Each unit comes complete.

More information

Selecting Energy Efficient New Windows in Florida

Selecting Energy Efficient New Windows in Florida Selecting Energy Efficient New Windows in Florida www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified

More information

Selecting Energy Efficient New Windows in California

Selecting Energy Efficient New Windows in California Selecting Energy Efficient New Windows in California www.efficientwindows.org Janurary 016 Zones 1. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

iku windows the intelligent self cleaning window AUTOMATIC system

iku windows the intelligent self cleaning window AUTOMATIC system iku windows is a aluminium sliding window system with two rails and double thermal breakage. By adding the iku box underneath the window sill it becomes an intelligent window. Functions Automatic opening

More information

Selecting Energy Efficient New Windows in Texas

Selecting Energy Efficient New Windows in Texas Selecting Energy Efficient New Windows in Texas www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified

More information

Ecofys VII U-Values for Better Energy Performance of Buildings

Ecofys VII U-Values for Better Energy Performance of Buildings Ecofys VII U-Values for Better Energy Performance of Buildings Quantifying the potential I II III IV & V VI Climate Protection Regulation Cost Effectiveness Enlarged EU Price Scenario Key figures from

More information

September 2007. September 2013. Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. info @ akt-uk.com www.akt-uk.

September 2007. September 2013. Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. info @ akt-uk.com www.akt-uk. Consulting Structural and Civil Engineers 100 St John Street London EC1M 4EH T +44 (0) 20 7250 7777 F +44 (0) 20 7250 7555 info @ akt-uk.com www.akt-uk.com 3290 A031234 The 196-222 Joseph Kings Bloggs

More information

Integral Shading & Privacy Solutions

Integral Shading & Privacy Solutions Integral Shading & Privacy Solutions Manual Magnetic Blinds Betweenglassblinds offer a versatile and contemporary means of privacy and shading suitable for large door panels, screens, office partitioning,

More information

WINDOW FILM. Buyer s Guide

WINDOW FILM. Buyer s Guide WINDOW FILM Buyer s Guide Improve Your Windows Window film can do more than simply block out the sun. The benefits of window film can improve your home, increase your comfort and help you enjoy your home

More information

STANDARD EXTRUDED HEAT SINKS

STANDARD EXTRUDED HEAT SINKS STANDARD EXTRUDED HEAT SINKS ABHA101 Weight: 0.4oz (11.34g) ABHA102 Weight: 0.5oz (14.17g) STANDARD EXTRUDED HEAT SINKS ABHA103 Weight: 0.2oz (5.57g) For use with DIPs and SRAMs ABHA104 Weight: 0.1oz (2.83g)

More information

Translucent Facades. Express your creativity start planning with Rodeca. Aesthetics Functionality Efficiency

Translucent Facades. Express your creativity start planning with Rodeca. Aesthetics Functionality Efficiency Translucent Facades Express your creativity start planning with Rodeca Aesthetics Functionality Efficiency ade by Rodeca Translucent facades Facades reflect in many ways the function of clothing. They

More information

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

Energy audit in Finland

Energy audit in Finland Energy audit in Finland NorTech Oulu Lauri Mikkonen Energy Audit in Finland An energy audit tells about the energy efficiency and total energy consumption in a building, including all consumed heating,

More information

Light Architecture. Colors Sweden. Light

Light Architecture. Colors Sweden. Light Light Architecture Danpalon is the complete daylighting solution offering exceptional quality of light, thermal insulation and UV protection with a rich non-industrial visual appeal. The Danpalon system

More information

BUILDING ENERGY DEMAND AGGREGATION AND SIMULATION TOOLS A DANISH CASE STUDY

BUILDING ENERGY DEMAND AGGREGATION AND SIMULATION TOOLS A DANISH CASE STUDY BUILDING ENERGY DEMAND AGGREGATION AND SIMULATION TOOLS A DANISH CASE STUDY P. Gianniou; A. Heller; C. Rode Department of Civil Engineering, Technical University of Denmark, Kgs. Lyngby ABSTRACT Nowadays,

More information

Improving thermal insulation of concrete sandwich panel buildings

Improving thermal insulation of concrete sandwich panel buildings Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general

More information

FABRIC ENERGY EFFICIENCY FOR PART L 2013

FABRIC ENERGY EFFICIENCY FOR PART L 2013 Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub

More information

Selecting Energy Efficient Replacement Windows in Nevada

Selecting Energy Efficient Replacement Windows in Nevada Selecting Energy Efficient Replacement Windows in Nevada www.efficientwindows.org January 06 STAR Zones. Meet the Energy Code & Look for the STAR Windows must comply with your local energy code. Windows

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

How To Test A Base Axe

How To Test A Base Axe Scotch-Weld DP760 Product Data Sheet Updated : February 2009 Supersedes: June 2001 Product Description DP760 epoxy adhesive is a non-sag, two-part room temperature curing adhesive designed for use when

More information

Selecting Energy Efficient New Windows in Georgia

Selecting Energy Efficient New Windows in Georgia Selecting Energy Efficient New Windows in Georgia www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.

More information

Constructions Database User Guide <Virtual Environment> 5.9

Constructions Database User Guide <Virtual Environment> 5.9 Constructions Database User Guide 5.9 Page 1 of 35 Contents 1. Introduction...3 2. Units...4 3. Main Dialogue Project Constructions...5 3.1. Outline...5 3.2. Construction Classes

More information

Selecting Energy Efficient New Windows in Arizona

Selecting Energy Efficient New Windows in Arizona Selecting Energy Efficient New Windows in Arizona www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.

More information

Energy Efficient HVAC-system and Building Design

Energy Efficient HVAC-system and Building Design Energy Efficient HVAC-system and Building Design Maija Virta 1, Harri Itkonen 1, Panu Mustakallio 1, Risto Kosonen 1 1 Halton Oy, Finland Corresponding email: maija.virta@halton.com SUMMARY This paper

More information

Avantis 75. Windows & Doors. Sapa Building System

Avantis 75. Windows & Doors. Sapa Building System Avantis 75 Windows & Doors Sapa Building System Avantis 75 is a thermally broken three-chamber window and door system, which sets the highest standards of thermal insulation and stability. Avantis 75

More information

Plaisance 50. Windows and doors. Sapa Building System

Plaisance 50. Windows and doors. Sapa Building System Plaisance 50 Windows and doors Sapa Building System Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a building depth. The system offers a wide range of inward and outward

More information

Lead architect: Ron Arad Architects - Executive architect: Jaspers & Eyers

Lead architect: Ron Arad Architects - Executive architect: Jaspers & Eyers SOLUTIONS FOR SUSTAINABLE BUILDINGS THE GUIDE TO BREEAM Lead architect: Ron Arad Architects - Executive architect: Jaspers & Eyers Reynaers develops innovative and sustainable aluminium solutions, for

More information

Impact-Resistant Windows and Sliding Glass Doors

Impact-Resistant Windows and Sliding Glass Doors Impact-Resistant Windows and Sliding Glass Doors Make Your Home A SafeHarbor. SafeHarbor Impact-Resistant Windows and Sliding Glass Doors are designed to look like traditional windows and doors, but they

More information

Paver glassblocks. Vetro Expo s.r.l. Thame the Light. www.vetroexpo.it. VETRO EXPO srl 23894 Cremella (LC) Version 2008

Paver glassblocks. Vetro Expo s.r.l. Thame the Light. www.vetroexpo.it. VETRO EXPO srl 23894 Cremella (LC) Version 2008 Paver glassblocks Terme Bains les Bains (88) Architetto : De Gastines (Paris IVe) - Impresa : Gros-oeuvre oeuvre : BDW (68) Fotografie: Pavés & Bains les bains: S. Dondicol Mairie de Harnes : P. Kozlowski

More information

GUJARAT TECHNOLOGICAL UNIVERSITY

GUJARAT TECHNOLOGICAL UNIVERSITY GUJARAT TECHNOLOGICAL UNIVERSITY ELECTRICAL & ELECTRONICS ENGINEERING (08) & ELECTRICAL ENGINEERING (09) ELECTRICAL POWER GENERATION SUBJECT CODE: 2140908 B.E. 4 th SEMESTER Type of Course: Engineering

More information

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND

More information

Conservatory Roof Structural Information Guide

Conservatory Roof Structural Information Guide Conservatory Roof Structural Information Guide Effective from ugust 8 Useful Information This guide displays data on the permissible roof member spans and for different roof loadings; it should be used

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK to provide product conformity Stocking Lane High Wycombe Buckinghamshire HP14 4ND Contact: Mr Alan Gower Tel: +44 (0)1494 569700 Fax: +44 (0)1494 569701

More information

COUNTRY REPORT: Portugal

COUNTRY REPORT: Portugal COUNTRY REPORT: Portugal Prepared by: Maria João Carvalho /LNEG Version 2 Date: 20 th October 2014 Address: Estrada do Paço do Lumiar,22 1649-038 LISBOA Tel. : +351 210924766 Fax : +351 217127195 E-mail:

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

1: Levelized Cost of Energy Calculation. Methodology and Sensitivity

1: Levelized Cost of Energy Calculation. Methodology and Sensitivity 1: Levelized Cost of Energy Calculation Methodology and Sensitivity What is LCOE? Levelized Cost of Energy (LCOE) is the constant unit cost (per kwh or MWh) of a payment stream that has the same present

More information

UNDERGRADUATE DEGREE PROGRAMME IN ELECTRICAL ENGINEERING. School of Industrial Engineering, Albacete

UNDERGRADUATE DEGREE PROGRAMME IN ELECTRICAL ENGINEERING. School of Industrial Engineering, Albacete UNDERGRADUATE DEGREE PROGRAMME IN ELECTRICAL ENGINEERING School of Industrial Engineering, Albacete Higher Technical School of Industrial Engineering, Ciudad Real Polytechnic University School, Almadén

More information

Achieving BREEAM credits with advanced glazing products from NSG Group

Achieving BREEAM credits with advanced glazing products from NSG Group Achieving BREEAM credits with advanced glazing products from NSG Group GROUP 01 BREEAM is the world s most widely used environmental assessment method for buildings. In this publication, we describe how

More information

Certification of solar collectors, solar water heaters and installers of solar water heaters - general introduction

Certification of solar collectors, solar water heaters and installers of solar water heaters - general introduction Certification of solar collectors, solar water heaters and installers of solar water heaters - general introduction Jan Erik Nielsen, SolarKey Int. What is certification? A product certificate is e.g.

More information

Confort 26. Sliding Systems. Sapa Building System

Confort 26. Sliding Systems. Sapa Building System Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are

More information

APPENDIX 11.1 Net Capital Expenditures

APPENDIX 11.1 Net Capital Expenditures APPENDIX 11.1 Capital Expenditures This page is intentionally left blank. Development Plan: Development Plan Related Economics: Reference All Gas Annual Capital Expenditures Market Prices: Reference (in

More information

UIA- INVESTMENT IN ENERGY PROJECTS IN LATIN AMERICA B Y: L I S A D O M I N G U E Z PA N A M A - F E B R U A R Y 2 8, 2 01 5

UIA- INVESTMENT IN ENERGY PROJECTS IN LATIN AMERICA B Y: L I S A D O M I N G U E Z PA N A M A - F E B R U A R Y 2 8, 2 01 5 UIA- INVESTMENT IN ENERGY PROJECTS IN LATIN AMERICA B Y: L I S A D O M I N G U E Z PA N A M A - F E B R U A R Y 2 8, 2 01 5 A. PANAMA: LATEST INTERNATIONAL PUBLIC BIDS ORGANIZED BY THE REGULATOR 2015 No.

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Single- Serve Coffee A Partial Environmental Inventory

Single- Serve Coffee A Partial Environmental Inventory Single- Serve Coffee A Partial Environmental Inventory Valerie M. Thomas 1 School of Industrial and Systems Engineering, and School of Public Policy Georgia Institute of Technology http://www.isye.gatech.edu/~vthomas

More information

Design qualification and type approval of PV modules

Design qualification and type approval of PV modules Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance

More information

Physics PH1FP. (Jun15PH1FP01) General Certificate of Secondary Education Foundation Tier June 2015. Unit Physics P1. Unit Physics P1 TOTAL

Physics PH1FP. (Jun15PH1FP01) General Certificate of Secondary Education Foundation Tier June 2015. Unit Physics P1. Unit Physics P1 TOTAL Centre Number Surname Candidate Number For Examiner s Use Other Names Candidate Signature Examiner s Initials Question Mark Science A Unit Physics P1 Physics Unit Physics P1 Friday 12 June 2015 General

More information

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009 d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control

More information

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products 10 reasons for an energy labeling system (1/2) The buildings sector is responsible for a considerable share of final

More information

Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability

Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability Florian Speier Swiss Architect CPHC co-founder, Zola European Windows What makes a window perform?

More information

SCHOTT PYRANOVA Planline System

SCHOTT PYRANOVA Planline System Schott_050_Pyranova_E_RZ.fh8.07.005 0:50 Uhr Seite HOME T E C H The Planline system The patented glass fixing method is a clear multi- is based on a fire resistant double glazed allows quick and easy replacement

More information

What is Solar Control?

What is Solar Control? A better environment inside and out. Solar, Safety and Security Window Films: Tech Bulletin Understanding Solar Performance Solar Gard solar control window films use advanced technology to benefit consumers

More information

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW

More information

CI/SfB. The Pilkington Glass Range. Ro3 November 2009

CI/SfB. The Pilkington Glass Range. Ro3 November 2009 CI/SfB The Pilkington Glass Range (41) Ro3 November 2009 Pilkington. Everything you need in glass from the experts. We have been manufacturing and processing glass since 1826. This experience has been

More information

Guide to the safe installation of downlighters in dwellings

Guide to the safe installation of downlighters in dwellings Guide to the safe installation of downlighters in dwellings Technical guidance for designers and installers 01 Guide to the safe installation of downlighters in dwellings Technical guidance for designers

More information

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies 2009-01-22 January 2009 Design qualification

More information

May 26, 2011, Strategic Planner Circle Innovation Management at Siemens Building Technologies Division Lucas Schmid, Head of Strategy

May 26, 2011, Strategic Planner Circle Innovation Management at Siemens Building Technologies Division Lucas Schmid, Head of Strategy May 26, 2011, Strategic Planner Circle Innovation Management at Siemens Building Technologies Division Lucas Schmid, Head of Strategy Siemens AG 2011. All rights reserved. Areas Contents of activity Building

More information

Modular Accommodation Solutions. Flexibility, efficiency and quality in one complete package

Modular Accommodation Solutions. Flexibility, efficiency and quality in one complete package Modular Accommodation Solutions Flexibility, efficiency and quality in one complete package Welcome Our Services Providing Your Solutions The clients who work with SEDAC Accommodation Solutions are extremely

More information

Linear thermal transmittance of the assembly of the glazing and the frame in windows

Linear thermal transmittance of the assembly of the glazing and the frame in windows Linear thermal transmittance of the assembly of the glazing and the frame in windows Svend Svendsen,Professor, Technical University of Denmark; ss@byg.dtu.dk; www.byg.dtu.dk Jacob B. Laustsen, Assistant

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Testing Rules for Thermal Conductivity October 2015

Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity (October 2015) 1 Normative references (to be inserted as additional chapter in the Testing Rules for Panels) 1.

More information

Minergie and Minergie-P, the Swiss Energy Labels Armin Binz, Institute of Energy in Building

Minergie and Minergie-P, the Swiss Energy Labels Armin Binz, Institute of Energy in Building Minergie and MinergieP, the Swiss Energy Labels Armin Binz, Institute of Energy in Building Energy and Sustainability from Concepts to Labels Concepts Methods and Instruments Standards and Labels SIA 8/,

More information

fr fire retardant MARMOLEUM

fr fire retardant MARMOLEUM MARMOLEUM fr fire retardant MARMOLEUM fr 63038 63173 63174 sahara van gogh caribbean 63120 63163 63164 indian summer opera rosato 63182 63055 63030 blue fresco blue lapponia 63032 63146 63048 graphite

More information

CI/Sf/B. (31) Ro6 (M5) November 2012. Pilkington Solar Control Range

CI/Sf/B. (31) Ro6 (M5) November 2012. Pilkington Solar Control Range CI/Sf/B (31) Ro6 (M5) November 2012 Pilkington Solar Control Range Contents Energy efficiency in buildings Solar Control How it works Low-emissivity (thermal insulation) How it works Introduction to the

More information