5

6

7

8

9 THERMAL CHARACTERISTICS Nominal operating cell temperature(noct) [ C] 48,2±2 48 Temperature coefficient P MPP [%K] -0,41-0,47 Temperature coefficient I SC [%K] 0,05 0,04 Temperature coefficient U OC [%K] -0,29-0,33 DESCRIPTION Solar cells Polycrystalline Si, 156 x 156 mm Monocrystalline Si, 156 x 156 mm Cell encapsulation Ethylene vinyl acetate (EVA) Ethylene vinyl acetate (EVA) Front Tempered solar glass, 4 / 3,2 mm Tempered solar glass, 4 / 3,2 mm Back Composite polyester film Composite polyester film Frame Anodized aluminium frame with twin-wall profile and drainage holes Anodized aluminium frame with twin-wall profile and drainage holes Junction box Tyco with 3 bypass diodes, IP65 Tyco with 3 bypass diodes, IP65 Cable and connectors OPERATING CONDITIONS Solar cable 4mm 2, lenght 1000 mm, Tyco SOLARLOK or PV4 connectors Solar cable 4mm 2, lenght 1000 mm, Tyco SOLARLOK or PV4 connectors Temperature range [ C] -40 to to +85 Maximum system voltage [V] Maximum surface load capacity Tested up to 5400 Pa (Snow load test) Tested up to 5400 Pa (Snow load test) Resistance against hail WARRANTIES AND CERTIFICATIONS Maximum diameter of 25 mm with impact speed of 23 m/s Maximum diameter of 25 mm with impact speed of 23 m/s Product warranty 15 years 15 years Performance warranty Power output of 90% for 12 years and 80% for 25 years Power output of 90% for 12 years and 80% for 25 years Product quality certificate EN IEC 61215: 2005 EN IEC 61215: 2005 Product quality certificate The Microcogeneration Scheme Certificate The Microcogeneration Scheme Certificate Product safety certificate EN IEC :2007 and : 2007 EN IEC :2007 and : 2007 Quality management certificate ISO 9001: 2008 ISO 9001: 2008 Environmental management certificate ISO 14001: 2004 ISO 14001: 2004 Occupational health and safety OHSAS 18001: 2007 OHSAS 18001: 2007 management certificate Recycling of photovoltaic module waste PV Cycle PV Cycle

10 SV / D SV / D SV / D SV / D Peak power P MPP [W] Peak power tolerance [W] -0/+4,9 Short circuit current I SC [A] 8,66 8,73 8,82 8,85 Open circuit voltage U OC [V] 37,1 37,4 37,6 37,7 Rated current I MPP [A] 8,07 8,16 8,30 8,37 Rated voltage U MPP [V] 29,9 30,2 30,4 30,5 Current and voltage tolerance [%] ±3 MECHANICAL DATA Dimensions (H x W x D) [mm] 1650 x 992 x 40 / 1663 x 998 x 42 Weight [kg] 18,70 / 19,00 WARRANTIES AND CERTIFICATIONS Product warranty 15 years Performance warranty Power output 90% for 12 years and 80% for 25 years Product quality certificate EN IEC 61215: 2005 Product quality certificate The Microgeneration Scheme Certificate Product safety certificate EN IEC : 2007 and EN IEC : 2007 Quality management certificate ISO 9001: 2008 Environmental management certificate ISO 14001: 2004 Occupational health and safety management certificate OHSAS 18001: 2007 MODEL SV D SV D SV D SV D Peak power P MPP [W] Peak power tolerance [W] -0/+4,9 Short circuit current I SC [A] 8,66 8,73 8,82 8,85 Open circuit voltage U OC [V] 33,4 33,6 33,8 34,0 Rated current I MPP [A] 8,07 8,15 8,29 8,35 Rated voltage U MPP [V] 26,9 27,2 27,4 27,5 Current and voltage tolerance [%] ± 3 MECHANICAL DATA Dimensions (H x W x D) [mm] 1505 x 998 x 42 Weight [kg] 18 WARRANTIES AND CERTIFICATIONS Product warranty Performance warranty 15 years Power output 90% for 12 years and 80% for 25 years Product quality certificate EN IEC 61215: 2005 Product quality certificate The Microgeneration Scheme Certificate Product safety certificate EN IEC : 2007 and EN IEC : 2007 Quality management certificate ISO 9001: 2008 Environmental management certificate ISO 14001: 2004 Occupational health and safety management certificate OHSAS 18001: 2007

11 MODEL SV D SV D SV D Peak power P MPP [W] Peak power tolerance [W] -0/+4,9 Short circuit current I SC [A] 8,63 8,73 8,82 Open circuit voltage U OC [V] 29,5 29,9 30,1 Rated current I MPP [A] 8,01 8,15 8,31 Rated voltage U MPP [V] 23,8 24,2 24,3 Current and voltage tolerance [%] ± 3 MECHANICAL DATA Dimensions (H x W x D) [mm] 1346 x 998 x 42 Weight [kg] 17 WARRANTIES AND CERTIFICATIONS Product warranty 15 years Performance warranty Power output 90% for 12 years and 80% for 25 years Product quality certificate EN IEC 61215: 2005 Product quality certificate The Microgeneration Scheme Certificate Product safety certificate EN IEC : 2007 and EN IEC : 2007 Quality management certificate ISO 9001: 2008 Environmental management certificate ISO 14001: 2004 Occupational health and safety management certificate OHSAS 18001: 2007

12 MODEL SV E / ED SV E / ED SV E / ED SV E / ED Peak power P MPP [W] Peak power tolerance [W] -0/+4,9 Short circuit current I SC [A] 8,58 8,63 8,69 8,75 Open circuit voltage U OC [V] 37,7 38,2 38,6 39,1 Rated current I MPP [A] 8,15 8,24 8,34 8,42 Rated voltage U MPP [V] 30,7 31,0 31,3 31,6 Current and voltage tolerance [%] ± 3 MECHANICAL DATA Dimensions (H x W x D) [mm] 1650 x 992 x 40 / 1663 x 998 x 42 Weight [kg] 18,70 / 19,00 WARRANTIES AND CERTIFICATIONS Product warranty 15 years Performance warranty Power output 90% for 12 years and 80% for 25 years Product quality certificate EN IEC 61215: 2005 Product quality certificate The Microgeneration Scheme Certificate Product safety certificate EN IEC : 2007 and EN IEC : 2007 Quality management certificate ISO 9001: 2008 Environmental management certificate ISO 14001: 2004 Occupational health and safety management certificate OHSAS 18001: 2007 MODEL SV ED SV ED SV ED SV ED Peak power P MPP [W] Peak power tolerance [W] -0/+4,9 Short circuit current I SC [A] 8,58 8,63 8,69 8,75 Open circuit voltage U OC [V] 34,0 34,3 34,7 35,2 Rated current I MPP [A] 8,16 8,24 8,36 8,44 Rated voltage U MPP [V] 27,6 27,9 28,1 28,4 Current and voltage tolerance [%] ± 3 MECHANICAL DATA Dimensions (H x W x D) [mm] 1505 x 998 x 42 Weight [kg] 18 WARRANTIES AND CERTIFICATIONS Product warranty 15 years Performance warranty Power output 90% for 12 years and 80% for 25 years Product quality certificate EN IEC 61215: 2005 Product quality certificate The Microgeneration Scheme Certificate Product safety certificate EN IEC : 2007 and EN IEC : 2007 Quality management certificate ISO 9001: 2008 Environmental management certificate ISO 14001: 2004 Occupational health and safety management certificate OHSAS 18001: 2007

13 MODEL SV ED SV ED SV ED Peak power P MPP [W] Peak power tolerance [W] -0/+4,9 Short circuit current I SC [A] 8,58 8,67 8,72 Open circuit voltage U OC [V] 30,2 30,7 31,1 Rated current I MPP [A] 8,14 8,30 8,41 Rated voltage U MPP [V] 24,6 24,9 25,1 Current and voltage tolerance [%] ± 3 MECHANICAL DATA Dimensions (H x W x D) [mm] 1346 x 998 x 42 Weight [kg] 17 WARRANTIES AND CERTIFICATIONS Product warranty 15 years Performance warranty Power output 90% for 12 years and 80% for 25 years Product quality certificate EN IEC 61215: 2005 Product quality certificate The Microgeneration Scheme Certificate Product safety certificate EN IEC : 2007 and EN IEC : 2007 Quality management certificate ISO 9001: 2008 Environmental management certificate ISO 14001: 2004 Occupational health and safety management certificate OHSAS 18001: 2007

14

15

16

17 SOLVIS Power: 21 kwp Project type: On-grid system Location: Croatia Relatio Power: 520 kwp Project type: On-grid system Location: Germany Highway Zagreb - Rijeka Power: 270 kwp Project type: On-grid system Location: Croatia Power: 40 kwp Project type: On-grid system Location: Slovenia Kindergarden Slovenska Bistrica Power: 30 kwp Project type: On-grid system Location: Slovenia Kijevo Community Power: 27 kwp Location: Croatia University Rijeka Power: 22 kwp Project type: On-grid system Location: Croatia Musongati park, Afrika Power: 15 kwp Location: Burundi Power: 13 kwp Project type: On-grid system Location: Germany

18

19

20 = =

ENERGIA SOLAR FOTOVOLTAICA

ENERGIA SOLAR FOTOVOLTAICA ENERGIA SOLAR FOTOVOLTAICA La energía solar fotovoltaica es un procedimiento de obtención de energía eléctrica a través de módulos fotovoltaicos. Estos módulos son elementos colectores formados por dispositivos

More information

PREMIUM CLASS PHOTOVOLTAICS

PREMIUM CLASS PHOTOVOLTAICS PREMIUM CLASS PHOTOVOLTAICS ENGLISH A CNBM COMPANY PREMIUM CLASS PHOTOVOLTAICS Our successful flagship is the brand PowerMax. PowerMax modules offer a high energy yield (kwh per kwp), possible due to broad

More information

Your Sharp system will be supplied with one of the following sets of panels:

Your Sharp system will be supplied with one of the following sets of panels: Sharp3000 3kW Solar System Panel Specifications Your Sharp system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum 3000

More information

SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list

SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list Nr Indeks Type of modules Set components Peak Power [Pmax] Net price 1 SOLARFLEX 36W Flex flexible

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Long-term performance of photovoltaic modules Artur Skoczek

Long-term performance of photovoltaic modules Artur Skoczek 1 Long-term performance of photovoltaic modules Artur Skoczek 2 The European Solar Test Installation (ESTI) has the primary objective of providing the scientific and technological basis for a sound and

More information

INSTALLATION MANUAL FOR PV MODULES ENGLISH VERSION 01 - SEPTEMBER 2013. www.ldksolar.com

INSTALLATION MANUAL FOR PV MODULES ENGLISH VERSION 01 - SEPTEMBER 2013. www.ldksolar.com INSTALLATION MANUAL FOR PV MODULES ENGLISH VERSION 01 - SEPTEMBER 2013 1 Installation Manual ENGLISH 1. Introduction This manual contains information regarding the safe installation and handling of photovoltaic

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

ADDENDUM #1(BID PACKAGE # 3)

ADDENDUM #1(BID PACKAGE # 3) H2Engineering, Inc. 114 East Fifth Avenue Tallahassee, FL 32303 Phone 850.224.7922 Fax 850.224.5876 ADDENDUM #1(BID PACKAGE # 3) To: Jeff Williams From: Peter Lindstrom Co: Leon County Date: October 04,

More information

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies 2009-01-22 January 2009 Design qualification

More information

PHOTOVOLTAIC SYSTEMS. Alessandro Massi Pavan

PHOTOVOLTAIC SYSTEMS. Alessandro Massi Pavan PHOTOVOLTAIC SYSTEMS Alessandro Massi Pavan Sesto Val Pusteria June 22 nd 26 th, 2015 GRID-CONNECTED PV PLANTS DISTRIBUTED TIPO DISTRIBUITO PV GENERATOR LOCAL LOADS INVERTER GRID CENTRALIZED PV GENERATOR

More information

ANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications

ANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications ANTENERGY Powered By BOSCH Cells Portable Solar Panel Kit User Manual and Product Specifications IMPORTANT Read instructions before operation. 1 / 12 Index Getting to know your Portable Solar Panel Kit

More information

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 How do I determine the PTC rating of a module? PTC refers to PVUSA Test Conditions, which were developed to test and compare

More information

ASI OEM Outdoor Solar Modules

ASI OEM Outdoor Solar Modules SOLAR PHOTOVOLTAICS ASI OEM OUTDOOR E ASI OEM Outdoor Solar Modules for innovative autarchic electronic devices More Energy Double-stacked cells Stable performance Reliability and Quality Made in Germany

More information

WATERPROOF PHOTOVOLTAIC SYSTEM

WATERPROOF PHOTOVOLTAIC SYSTEM WATERPROOF PHOTOVOLTAIC SYSTEM Nola, the biggest BIPV plant in the world. 25 MWp 9 KWp 7 KWp 580 KWp 110 KWp 20 KWp 430 KWp Synthetic layer - 50 KWp Synthetic layer - 30 KWp Synthetic layer -9 KWp STOPPING

More information

Design qualification and type approval of PV modules

Design qualification and type approval of PV modules Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance

More information

For the modifications listed below, the Qualification Approval tests in IEC 61215 and IEC 61646, shall be used as a guideline by the assessor:

For the modifications listed below, the Qualification Approval tests in IEC 61215 and IEC 61646, shall be used as a guideline by the assessor: Product or Process Modifications Requiring Limited CBTL Retesting to Maintain Certification This document sets forth a uniform approach to maintain the certification of products that have, or will, undergo

More information

NOCT: Normal Operation Cell Temperature

NOCT: Normal Operation Cell Temperature Let the sunshine in. Compendium for SOLARWATTsystems and components www.solarwatt.de Valid from 1/9/214 New New and interesting for your business: Package offers with price advantages for various modules:

More information

LN240(30)P-3-xxx (230-250W poly)

LN240(30)P-3-xxx (230-250W poly) LN240(30)P-3-xxx (230-250W poly) Why Linuo Modules? 100% EL testing before and after lamination 100% plus tolerance(0-+3%) 100% insured by CHUBB Exceptional performance under low solar irradiance imized

More information

Design of Grid Connect PV systems. Palau Workshop 8 th -12 th April

Design of Grid Connect PV systems. Palau Workshop 8 th -12 th April Design of Grid Connect PV systems Palau Workshop 8 th -12 th April INTRODUCTION The document provides the minimum knowledge required when designing a PV Grid connect system. The actual design criteria

More information

PHOTOVOLTAIC ENERGY SOLUTIONS FOR PROFESSIONALS

PHOTOVOLTAIC ENERGY SOLUTIONS FOR PROFESSIONALS PHOTOVOLTAIC ENERGY SOLUTIONS FOR PROFESSIONALS catalogue GPC Europe photovolaic energy solutions for professionals GPC Europe is a specialized wholesaler in PV-panels and accessories and has proven its

More information

SolarMax P series The power package for residential solar plants

SolarMax P series The power package for residential solar plants SolarMax P series The power package for residential solar plants The future-proof solution The requirements for residential photovoltaic plants have increased continuously in the past years. Due to our

More information

PV module safety qualification according to IEC 61730:2004 EN 61730:2007

PV module safety qualification according to IEC 61730:2004 EN 61730:2007 PV module safety qualification according to IEC 61730:2004 EN 61730:2007 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies January 2009 Version 2009-01-22 Overview The long term

More information

245-310 W POWER OUTPUT RANGE

245-310 W POWER OUTPUT RANGE Mono Multi Solutions THE OPTIMIZED SOLUTION COMPTIBLE WITH MOST TRIN MODULES Safer Solar Panel-level disconnect to remotely deactivate modules rc, fire and safety hazard mitigation 245-310 W POWER OUTPUT

More information

Replacing Fuel With Solar Energy

Replacing Fuel With Solar Energy Replacing Fuel With Solar Energy Analysis by Michael Hauke, RSA Engineering January 22, 2009 The Right Place for Solar Energy Harvesting solar energy at South Pole can reduce the fuel consumption needed

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

YINGLI SOLAR PV MODULES Installation and User Manual

YINGLI SOLAR PV MODULES Installation and User Manual YINGLI SOLAR PV MODULES Installation and User Manual Revision Date December 24, 2011 Applicable for IEC certified products This manual applies to photovoltaic modules ( PV modules, also commonly known

More information

Hammarby Sjöstad Kv Lugnvattnet PV-Project: "Lysande"

Hammarby Sjöstad Kv Lugnvattnet PV-Project: Lysande Hammarby Sjöstad Kv Lugnvattnet PV-Project: "Lysande" TECHNICAL DESCRIPTION PV System TENDER DOCUMENT Stockholm 2002-03-15 Created by: Jonas Hedström, Energibanken i Jättendal AB 1 Tender document for

More information

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting 12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.

More information

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES GENERAL INSTALLATION MANUAL FOR EGING PV MODULES PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE MODULES. PLEASE PASS ALONG THE ATTACHED USER MANUAL TO YOUR CUSTOMER. 1. INTRODUCTION This

More information

Introduction of PV related business of Japan Electrical Safety & Environment Technology Laboratories (JET)

Introduction of PV related business of Japan Electrical Safety & Environment Technology Laboratories (JET) Introduction of PV related business of Japan Electrical Safety & Environment Technology Laboratories (JET) 2015 PV Module Reliability Workshop Golden, Colorado, Thursday, February 26, 2015 Tadashi Obayashi,

More information

EGSTON Standard E2xFxWx 12W

EGSTON Standard E2xFxWx 12W General description The family of switchmode power supplies offers an unmatched degree of flexibility and performance fulfilling even the most stringent requirements. Highly flexible electrical configuration

More information

Photovoltaic Power: Science and Technology Fundamentals

Photovoltaic Power: Science and Technology Fundamentals Photovoltaic Power: Science and Technology Fundamentals Bob Clark-Phelps, Ph.D. Evergreen Solar, Inc. Renewable Energy Seminar, Nov. 2, 2006 Photovoltaic Principle Energy Conduction Band electron Energy

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Solar Cell Bypass Diodes in Silicon Crystalline Photovoltaic Panels

Solar Cell Bypass Diodes in Silicon Crystalline Photovoltaic Panels VISHAY GENERAL SEMICONDUCTOR www.vishay.com Rectifiers IMPORTANT CHARACTERISTICS OF BYPASS DIODES FOR PHOTOVOLTAIC SOLAR CELLS 1. Forward Voltage Drop (V F ) at Bypass The basic function of bypass diodes

More information

Coils - Connectors. Coils Connectors. Summary. RE 18325-90/12.10 1/10 Replaces: RE 18325-90/02.10. Description

Coils - Connectors. Coils Connectors. Summary. RE 18325-90/12.10 1/10 Replaces: RE 18325-90/02.10. Description RE 18325-90/12.10 1/10 Replaces: RE 18325-90/02.10 Coils Connectors Summary Description Page Description Page Coils Coil S8-356 - CLASS H - 20 W 2-3 Coil S8-356 - CLASS H - 17 W 4 Coil S5 - CLASS H 5 Coil

More information

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

In-Sight Hardware specifications

In-Sight Hardware specifications specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited

More information

A new entry in the list of the best modules. Applications & Installations

A new entry in the list of the best modules. Applications & Installations Photo: TÜV Rheinland In the PV+Test mechanical loading tests, solar photovoltaic modules are first subjected to a load of 2,400 pascals and then to 5,400 pascals. A new entry in the list of the best modules

More information

SunCharger Portable Solar Panel

SunCharger Portable Solar Panel SunCharger Portable Solar Panel Models: SC-05 SC-10 Owner's Manual Please read this manual BEFORE operating the units. OWNER'S MANUAL Index SECTION 1 Safety Instructions... 3 SECTION 2 General Information...

More information

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current

More information

We're with you... solar. Call 1800 332 332 today FOR THE LIFE OF THE SYSTEM YEAR WARRANTY * YEAR OLD BACKED BY CSR BRADFORD CSR A AUSTRALIAN COMPANY

We're with you... solar. Call 1800 332 332 today FOR THE LIFE OF THE SYSTEM YEAR WARRANTY * YEAR OLD BACKED BY CSR BRADFORD CSR A AUSTRALIAN COMPANY We're with you... FOR THE LIFE OF THE SYSTEM 25 YEAR WARRANTY * Electricity prices are predicted to continue to rise in the future. If you're serious about installing energy in your home, look no further

More information

Limited Warranty Letter for BYD Photovoltaic Module

Limited Warranty Letter for BYD Photovoltaic Module Limited Warranty Letter for BYD Photovoltaic Module BYD(Shangluo) Industrial Co., LTD ( BYD ) hereby provides this Limited Warranty ( Warranty ) with respect to certain types of its photovoltaic modules

More information

CHAPTER 4: TECHNICAL CHARACTERISTICS OF SOLAR FARM

CHAPTER 4: TECHNICAL CHARACTERISTICS OF SOLAR FARM CHAPTER 4: TECHNICAL CHARACTERISTICS OF SOLAR FARM 4.1 PRINCIPLE OF ELECTRICITY PRODUCTION FROM SOLAR IRRADIANCE Solar irradiance from the sun can provide an invaluable source of energy. Solar energy is

More information

Crystalline Silicon Terrestrial Photovoltaic Cells

Crystalline Silicon Terrestrial Photovoltaic Cells Crystalline Silicon Terrestrial Photovoltaic Cells Supply Chain Procurement Specification Guideline Prepared by Govindasamy TamizhMani Arizona State University Photovoltaic Reliability Laboratory Solar

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

ELG4126: Photovoltaic Materials. Based Partially on Renewable and Efficient Electric Power System, Gilbert M. Masters, Wiely

ELG4126: Photovoltaic Materials. Based Partially on Renewable and Efficient Electric Power System, Gilbert M. Masters, Wiely ELG4126: Photovoltaic Materials Based Partially on Renewable and Efficient Electric Power System, Gilbert M. Masters, Wiely Introduction A material or device that is capable of converting the energy contained

More information

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS ponto trasso ponto trasso CHARACTERISTICS - FLOODLIGHTS Ponto Trasso Seal tightness: IP 67 (*) Impact resistance (glass): IK 10 (**) Static load resistance: 500 kg (*) Nominal voltage: 230 V AC Electrical

More information

Solar Photovoltaic (PV) Cells

Solar Photovoltaic (PV) Cells Solar Photovoltaic (PV) Cells A supplement topic to: Mi ti l S Micro-optical Sensors - A MEMS for electric power generation Science of Silicon PV Cells Scientific base for solar PV electric power generation

More information

EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER

EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER A willingness to install east-west orientated photovoltaic (PV) systems has lacked in the past. Nowadays, however, interest in installing

More information

46120-F0 Solar Energy Training System

46120-F0 Solar Energy Training System 46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of

More information

Photovoltaic modules. Maximum quality, efficiency and reliability

Photovoltaic modules. Maximum quality, efficiency and reliability Photovoltaic modules Maximum quality, efficiency and reliability European quality, best prices ZYTECH PHOTOVOLTAIC MODULES Maximum quality, efficiency and reliability Modules with the best value for quality

More information

3M Products for Solar Energy. Designed for efficiency. Built to last.

3M Products for Solar Energy. Designed for efficiency. Built to last. 3M Products for Solar Energy Designed for efficiency. Built to last. 2 3M Products for Solar Energy From factory to field, 3M is with you. Every step of the way. Making solar power more efficient. More

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

Solibro Company Presentation AUGUST 2015

Solibro Company Presentation AUGUST 2015 Solibro Company Presentation AUGUST 2015 CONTENT COMPANY FACTS PRODUCTS & INSTALLATIONS QUALITY PRODUCTION PROCESS SERVICE SOLIBRO COMPANY PRESENTATION REV. 04 AUGUST 2015 2 SOLIBRO FACTS Part of the Hanergy

More information

ABOUT US. www.suncoreus.com P01/P02

ABOUT US. www.suncoreus.com P01/P02 Suncore USA Tel: +1-575-812-8080 Website: http://www.suncoreus.com E-mail: sales@suncoreus.com Address: 3825 Academy Pkwy South NE, Albuquerque, NM, USA Suncore China Tel: +86-554-5389998 Fax: +86-554-5389102

More information

SOLAR ChARge CONTROLLeRS

SOLAR ChARge CONTROLLeRS Steca Tarom MPPT 6000, 6000-M The Steca Tarom MPPT solar charge sets new standards in the area of Maximum Power Point trackers. Outstanding efficiency along with unique safety features make it a universal

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Guideline Laser Series

Guideline Laser Series Guideline Laser Series Highly visible alignment laser for visually demanding surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)

More information

Yield Reduction due to Shading:

Yield Reduction due to Shading: 1x4 1x16 10 x CBC Energy A/S x Danfoss Solar Inverters CBC-40W Poly 40 W TLX 1,5k 5 ; 1x11 3x4 0 1,5kW 1536 x CBC Energy A/S 1 x Power-One CBC-40W Poly 40 W TRIO-7,6-TL-OUTD 30 ; 4x14 0 7,6kW Location:

More information

MORE POWER. A BETTER INVESTMENT.

MORE POWER. A BETTER INVESTMENT. SUNPOWERCORP.COM US HEADQUARTERS SunPower Corporation 3939 N. 1st Street San Jose, California 95134 USA 1-800-SUNPOWER sunpowercorp.com MORE POWER. A BETTER INVESTMENT. Established Incorporated in 1985

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

Efficient and reliable operation of LED lighting is dependent on the right choice of current-limiting resistor

Efficient and reliable operation of LED lighting is dependent on the right choice of current-limiting resistor Efficient and reliable operation of LED lighting is dependent on the right choice of current-limiting resistor Phil Ebbert, VP of Engineering, Riedon Inc. Introduction Not all resistors are the same and

More information

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity

More information

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers Tape Wound, Split Core and Ebony Current Transformers Table of contents Tape Wound Measuring and Protection Current Transformers 2 MR Series Measuring Range 3 PR Series Protection Range 4 Class PX Current

More information

PERFORMANCE OF MPPT CHARGE CONTROLLERS A STATE OF THE ART ANALYSIS

PERFORMANCE OF MPPT CHARGE CONTROLLERS A STATE OF THE ART ANALYSIS PERFORMANCE OF MPPT CHARGE CONTROLLERS A STATE OF THE ART ANALYSIS Michael Müller 1, Roland Bründlinger 2, Ortwin Arz 1, Werner Miller 1, Joachim Schulz 2, Georg Lauss 2 1. STECA ELEKTRONIK GMBH, Mammostr.

More information

Safety and Installation Instructions for AC Modules

Safety and Installation Instructions for AC Modules Safety and Installation Instructions for AC Modules United States and Canada Contents of this manual are subject to change without notice. For the latest guide please refer to www.sunpower.com/pvinstallguideacmodule

More information

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat FREEZE Freezer equipment Canopy lighting High efficiency QCS Quick-Connection-System Dimmable Various lengths Daylight Neutral White Fresh Meat Packed Meat 1 A FREEZE Canopy PRODUCT DESCRIPTION 19.8 mm

More information

Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar

Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

Application Note - How to Design a SolarEdge System Using PVsyst

Application Note - How to Design a SolarEdge System Using PVsyst March 2015 Application Note - How to Design a SolarEdge System Using PVsyst As of version 5.20, PVsyst - the PV system design software - supports the design of SolarEdge systems. This application note

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

Heliene Modules. Technical Review. Final Report. September 2011

Heliene Modules. Technical Review. Final Report. September 2011 Helios Energy Europe, S.L. Pza. del Xarol, 13-15 :: Pol. Ind. Les Guixeres 08915 BADALONA - Spain Heliene Modules Technical Review Final Report September 2011 OST Energy 44 North Road Brighton BN1 1YR,

More information

LED DOWNLIGHT ONE 50XX SERIES

LED DOWNLIGHT ONE 50XX SERIES ONE 50XX LED reflectors are high power LED downlights ideal for mounting in lighting fixture frames. These downligths are available in few versions using CREE MK-R LED chip. All reflectors are supplied

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

UniPlate. Solar Collectors SOLAR SYSTEMS. www.solarico.eu

UniPlate. Solar Collectors SOLAR SYSTEMS. www.solarico.eu UniPlate Solar Collectors SOLAR SYSTEMS www.solarico.eu keep the sun in mind Solar energy has by far the highest theoretical potential of the earth s renewable energy sources. It is the most abundant energy

More information

Solar Energy Discovery Lab

Solar Energy Discovery Lab Solar Energy Discovery Lab Objective Set up circuits with solar cells in series and parallel and analyze the resulting characteristics. Introduction A photovoltaic solar cell converts radiant (solar) energy

More information

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with SOLAR MICRO INVERTER 260 COMMUNICATI GATEWAY Apparent Power Control (APC) P Q unique micro inverter with REAL & REACTIVE POWER CTROL 2 Micro Inverters unique micro inverter with real & reactive power control

More information

Monocrystalline Folding Solar Panels SMP1090 SMP1120 SMP1150

Monocrystalline Folding Solar Panels SMP1090 SMP1120 SMP1150 Monocrystalline Folding Solar Panels SMP1090 SMP1120 SMP1150 MONOCRYSTALLINE FOLDING SOLAR PANELS REDARC folding solar panels are designed to provide a solar charging solution for your house or auxiliary

More information

DISCRETE SEMICONDUCTORS DATA SHEET. BZX384 series Voltage regulator diodes. Product data sheet Supersedes data of 2003 Apr 01.

DISCRETE SEMICONDUCTORS DATA SHEET. BZX384 series Voltage regulator diodes. Product data sheet Supersedes data of 2003 Apr 01. DISCRETE SEMICONDUCTORS DATA SHEET Supersedes data of 2003 Apr 01 2004 Mar 22 FEATURES Total power dissipation: max. 300 mw Two tolerance series: ±2% and approx. ±5% Working voltage range: nominal 2.4

More information

Problem / Solution. The problem:

Problem / Solution. The problem: Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and

More information

YINGLI SOLAR PV MODULES Installation and User Manual

YINGLI SOLAR PV MODULES Installation and User Manual YINGLI SOLAR PV MODULES Installation and User Manual Revision Date March 1, 2012 Applicable for products in the United States and Canada. This manual applies to photovoltaic modules ( PV modules, also

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

sunmax Residential Solar Solution sunmax Hardware sunmax Software

sunmax Residential Solar Solution sunmax Hardware sunmax Software DATASHEET sunmax Residential Solar Solution The sunmax Residential Solar Solution provides a complete product solution including hardware and software. The sunmax hardware offers advantages such as simplified

More information

COOL Shelf Quick Connect

COOL Shelf Quick Connect Refrigeration equipment Shelf lighting High efficiency COOL QCS Quick-Connection-System Dimmable Various lengths Neutral White Warm White Pasta & Cheese Fresh Meat Packed Meat 1 A COOL Shelf Quick Connect

More information

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009 d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control

More information

PM200M00 PM245P00 PM250M01 PM300P00 PM318B00 PM318B01 PM096B00 PM096B01. Version 1.2

PM200M00 PM245P00 PM250M01 PM300P00 PM318B00 PM318B01 PM096B00 PM096B01. Version 1.2 BenQ Solar Photovoltaic Modules Installation Guide (IEC, ETL) PM200M00 PM245P00 PM250M01 PM300P00 PM318B00 PM318B01 PM096B00 PM096B01 Version 1.2 Note: The content of this manual is subject to change without

More information

Coils - Connectors. Coils Connectors. Summary. RE 18325-90/03.16 Replaces: RE 18325-90/07.15. Description

Coils - Connectors. Coils Connectors. Summary. RE 18325-90/03.16 Replaces: RE 18325-90/07.15. Description 1/22 Replaces: RE 18325-90/07.15 Coils Connectors Summary Description Page Description Page Coils Coil S8-356 - CLASS H - 20 W 2-3 Coil S8-356 - CLASS H - 17 W 4 Coil S8-356 - CLASS H - 17 W - LISTED UL

More information

Photovoltaic MOSFET Driver with Integrated Fast Turn-Off, Solid-State Relay

Photovoltaic MOSFET Driver with Integrated Fast Turn-Off, Solid-State Relay Photovoltaic MOSFET Driver with Integrated Fast Turn-Off, Solid-State Relay i7966_6 Turn Off FEATURES Open circuit voltage at I F = ma, 8. V typical Short circuit current at I F = ma, 5 μa typical Isolation

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

LONGTERM EXPERIENCE WITH PV POWER PLANTS IN GERMANY

LONGTERM EXPERIENCE WITH PV POWER PLANTS IN GERMANY LONGTERM EXPERIENCE WITH PV POWER PLANTS IN GERMANY Dr. Christian Reise Fraunhofer Institute for Solar Energy Systems ISE Freiburg, Germany Solar Operations & Maintenance Milan, October 9 th, 2013 The

More information

Solar energy... ...Solar technology in endurance testing

Solar energy... ...Solar technology in endurance testing Solar energy......solar technology in endurance testing Solar & Photovoltaic systems - Environmental testing...... we are your partner Energy generated by the sun (solar energy) is considered forward looking

More information