1 SUN CONTROL GLAZING SELECTIVE GLAZING FOR SUN CONTROL Sun Factor 1st level performance for direct solar energy Solar energy control Solar control coating Only if the glass is exposed to sun rays! 2nd level performance for direct solar energy Thermal barrier control Low emission insulating glazing Active 24/7! U-Value - Combination of 1st and 2nd level performances - 3rd level selective glass - Maximum performance

2 COMPARISON OF LOW EMISSION AND SELECTIVE GLASS Composition

3 High performance glass Sun factor = FS % Solar radiation incident on a vertical wall = 800 W/m2 Traditional Insulating Glazing Low Emission Insulating Glazing Energy N Selective Insulating Glazing

4 High Performance Glazing Comparison of performances in the summer Traditional insulating glazing VS Selective insulating glazing

5 High performance glass Comparison of performance in the summer Parameters taken into account: Residential housing on one level Climatic area E ( degree days, ex. Turin, Milan, Venice, Perugia ) Surface of the housing: 130 m2 Height of the rooms: 2.9 mt Total surface of the glazing: 22 m2 Conditions of standard occupation of the house (5 people) Data processing performed in the living room Room exposition: South-East Month: July

6 COMPARISON OF PERFORMANCES IN THE SUMMER Trend of indoor temperature Traditional insulating glazing (4/12/4) Energy insulating glazing (4/12/4) Outdoor temperature Ideal indoor temperature, according to UNI-ISO 7730

7 Comparison of performances n the summer period Trend of the indoor temperature, in air-conditioned housing Conditioning with traditional insulating glazing (4/12/4) Air conditioning working time: I.G. = 1h 45 minutes Selective I.G. = 30 minutes Conditioning with Energy insulating glazing (4/12/4) Traditional insulating glazing Energy insulating glazing Indoor pre-set temperature Air conditioning on/off

8 Analysis of the results Summer period (May September) Slow heating up of the rooms Reduction of the peaks in indoor temperature Lower overheating Considerable reduction of the cost of air conditioning; about 70% compared to a room with standard insulating glazing Reduction of the cost of purchase of an air conditioner

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Thermally Toughened Heat and Solar Control Glass 1 (C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics

More information

A Roof Integrated Solar Heating System Without Storage

A Roof Integrated Solar Heating System Without Storage M. and W. Saman Sustainable Energy Centre University of South Australia Mawson Lakes Boulevard, Mawson Lakes, SA 5095, Australia E-mail: [email protected] Abstract A prototype of a roof integrated

More information

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number 610.14351-R1D1. 13 January 2015

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number 610.14351-R1D1. 13 January 2015 EcoPelmet Pty Ltd c/- Geoff Hesford Engineering 45 Market Street FREMANTLE WA 6160 Version: Page 2 PREPARED BY: ABN 29 001 584 612 2 Lincoln Street Lane Cove NSW 2066 Australia (PO Box 176 Lane Cove NSW

More information

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING LI CHUNYING DOCTOR OF PHILOSOPHY CITY UNIVERSITY OF HONG KONG FEBRUARY 2012 CITY UNIVERSITY OF HONG KONG 香 港 城 市 大 學 Performance Evaluation of Water-flow

More information

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency

More information

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE LOW-E GLASS TECHNICAL GUIDE SELECTIVE INFRARED RADIATION FILTER Infrared radiation coming from natural sun light can cause a heat build-up inside building; This situation leads to thermal imbalance during

More information

Ecofys VII U-Values for Better Energy Performance of Buildings

Ecofys VII U-Values for Better Energy Performance of Buildings Ecofys VII U-Values for Better Energy Performance of Buildings Quantifying the potential I II III IV & V VI Climate Protection Regulation Cost Effectiveness Enlarged EU Price Scenario Key figures from

More information

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING R.M.J. Bokel Department of Architecture, Delft Technical University, Delft, The Netherlands,

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

Selecting Energy Efficient New Windows in Florida

Selecting Energy Efficient New Windows in Florida Selecting Energy Efficient New Windows in Florida www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified

More information

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Pilkington Activ The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Thermal insulation. When it comes to conservatories, we think

More information

Selecting Energy Efficient New Windows in Texas

Selecting Energy Efficient New Windows in Texas Selecting Energy Efficient New Windows in Texas www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified

More information

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Argon (90%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

Selecting Energy Efficient Replacement Windows in Nevada

Selecting Energy Efficient Replacement Windows in Nevada Selecting Energy Efficient Replacement Windows in Nevada www.efficientwindows.org January 06 STAR Zones. Meet the Energy Code & Look for the STAR Windows must comply with your local energy code. Windows

More information

Passive Solar Design and Concepts

Passive Solar Design and Concepts Passive Solar Design and Concepts Daylighting 1 Passive Solar Heating Good architecture? The judicious use of south glazing coupled with appropriate shading and thermal mass. Summer Winter Passive solar

More information

Tech Bulletin. Understanding Solar Performance

Tech Bulletin. Understanding Solar Performance Tech Bulletin Understanding Solar Performance Bekaert solar control window films use advanced technology to benefit consumers with quality solutions that enhance comfort and decrease energy use. By understanding

More information

Selecting Energy Efficient New Windows in Georgia

Selecting Energy Efficient New Windows in Georgia Selecting Energy Efficient New Windows in Georgia www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.

More information

Adaptive strategies for office spaces in the UK climate

Adaptive strategies for office spaces in the UK climate International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate

More information

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the

More information

Selecting Energy Efficient New Windows in Arizona

Selecting Energy Efficient New Windows in Arizona Selecting Energy Efficient New Windows in Arizona www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.

More information

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving 346 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving S. Ferrari Politecnico

More information

What is Solar Control?

What is Solar Control? A better environment inside and out. Solar, Safety and Security Window Films: Tech Bulletin Understanding Solar Performance Solar Gard solar control window films use advanced technology to benefit consumers

More information

Improving thermal insulation of concrete sandwich panel buildings

Improving thermal insulation of concrete sandwich panel buildings Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general

More information

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Self-Cleaning The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Conservatories bringing the outside in. Pilkington Activ has made

More information

ENERGY SAVING WINDOW FILMS S LAR CONTROL

ENERGY SAVING WINDOW FILMS S LAR CONTROL ENERGY SAVING WINDOW FILMS S LAR CONTROL Overview Managing Solar Heat Gain - Solar Control Window Film With an ever increasing need to achieve outstanding energy efficiency within buildings without compromising

More information

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015 www.zebra2020.eu Delivering on innovation and market uptake. Best-in-cases of nzeb Ramon Pascual Bucharest May 8th, 2015 Outline nzeb Database Best in cases of nzeb Climates in Europe Preliminary results

More information

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Self-cleaning Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories

More information

Retrofit EnerLogic Low-e Window Films

Retrofit EnerLogic Low-e Window Films Retrofit EnerLogic Low-e Window Films Steve DeBusk Global Architectural Technical Services Manager May 18, 2015 ORNL Envelope Stakeholder Workshop Eastman Overview Eastman Global specialty chemical company.

More information

Solar Energy Utilisation in Buildings

Solar Energy Utilisation in Buildings Solar Energy Utilisation in Buildings P. Karava, PhD Assistant professor Department of Civil and Environmental Engineering University of Western Ontario 2 Modern Buildings Change in architectural style

More information

How To Improve Energy Efficiency In Brazilian Buildings

How To Improve Energy Efficiency In Brazilian Buildings Bmeister Engenharia & Consultoria Texiglass EIFS / ETICS External Thermal Insulation Composite System INFLUENCE ON THERMAL PERFORMANCE OF BUILDINGS Eng. Giorgio Solinas Sales & Operations Director Texiglass

More information

ELIMINATING AIR CONDITIONERS IN NEW SOUTHERN CALIFORNIA HOUSING

ELIMINATING AIR CONDITIONERS IN NEW SOUTHERN CALIFORNIA HOUSING ELIMINATING AIR CONDITIONERS IN NEW SOUTHERN CALIFORNIA HOUSING Murray Milne, Research Professor Department of Architecture and Urban Design UCLA Los Angeles, CA 90095 [email protected] Tim Kohut, Project

More information

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace HEAT GAINS and LOSSES : ROOFS and WALLS Wall Roof Ts To Ts To Ti Ceiling/Airspace Ti Roof and wall are analyzed in the same way. In winter the heat loss is simple transmission based on the inside and outside

More information

Residential HVAC System Sizing

Residential HVAC System Sizing Residential HVAC System Sizing William P. Goss University of Massachusetts, Amherst, Massachusetts, USA Corresponding email: [email protected] SUMMARY Heating, ventilating and air-conditioning (HVAC)

More information

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1 Opening the Bonnet Prof Darren Woolf WYSINWYG 1 WYSINWYG What You See Is NOT What You Get: Looking inside the Pandora s Box Prof Darren Woolf WYSINWYG 2 WYSIWYG implies a user interface that allows the

More information

Constructions Database User Guide <Virtual Environment> 5.9

Constructions Database User Guide <Virtual Environment> 5.9 Constructions Database User Guide 5.9 Page 1 of 35 Contents 1. Introduction...3 2. Units...4 3. Main Dialogue Project Constructions...5 3.1. Outline...5 3.2. Construction Classes

More information

Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows

Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows By Steve DeBusk, CEM, CMVP Global Energy Solutions Manager CPFilms, a Subsidiary of Solutia Inc. Abstract Energy

More information

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows by The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows In Alliance with OCCUPANT COMFORT All of the windows above have the same exterior tint of glass. Why such a

More information

EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)

EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356) 4 (# 2) - 12-33.1, Heat Control Glass (Low-E #2) + Argon (90%) + Pendulum body impact resistance - 12-2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection

More information

薄 膜 對 提 高 樓 宇 窗 戶 性 能 的 研 究 分 析

薄 膜 對 提 高 樓 宇 窗 戶 性 能 的 研 究 分 析 Hui, S. C. M. and Kwok, M. K., 2006. Study of thin films to enhance window performance in buildings, In Proceedings of the Sichuan-Hong Kong Joint Symposium 2006, 30 June-1 July 2006, Chengdu, China, pp.

More information

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards Date of revision: 15.6.2012 Osram Culture Centre Copenhagen, Denmark Valhalsgade 4, 2200 Copenhagen N 1. INTRODUCTION PROJECT SUMMARY Construction year: 1953 Energy renovation: 2009 No past energy renovations

More information

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd. Double Glazing Glass Energy Saving Solutions Harris Silicones & Glass (Pvt.) Company Introduction Pioneers of Silicone Sealants in Pakistan Manufacturing in collaboration with Momentive Performance Materials

More information

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW

More information

1..GENERAL DATA 2. CLIMATIC DATA. Location

1..GENERAL DATA 2. CLIMATIC DATA. Location 1..GENERAL DATA Location Szentendre, Downtown, Hungary Property Community centre of Szentendre, Public, Municipality of Szentendre Year of Building: End of 19th Century Present use (1) Community centre

More information

In the Fall 2002 issue of HHE News I examined

In the Fall 2002 issue of HHE News I examined Choosing Replacement Windows 1 For Your Home Mark Pierce In the Fall 2002 issue of HHE News I examined reasons for, and against, replacing older windows with new, energy efficient windows. That article

More information

Adapting to Change: New Thinking on Comfort Natural ventilation in UK schools: design options for passive cooling Steven Firth* and Malcolm Cook

Adapting to Change: New Thinking on Comfort Natural ventilation in UK schools: design options for passive cooling Steven Firth* and Malcolm Cook Proceedings of Conference: Adapting to Change: New Thinking on Comfort Cumberland Lodge, Windsor, UK, 9-11 April 2010. London: Network for Comfort and Energy Use in Buildings, http://nceub.org.uk Natural

More information

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ Ref. No: 12/02870/FULM Contents 1. General... 2 2. Planning Condition... 2 3. Development...

More information

Case study on residential building renovation and its impact on the energy use and thermal comfort

Case study on residential building renovation and its impact on the energy use and thermal comfort Case study on residential building renovation and its impact on the energy use and thermal comfort Hanne Kauko, Maria Justo Alonso, Ole Stavset and Ingrid Camilla Claussen SINTEF Energy Research Motivation

More information

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE Energy and Sustainability 287 Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE M. A. Haggag UAE University, United Arab Emirates Abstract The city of Dubai,

More information

Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek

Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy For Tech Traders Inc. By H. F. Poppendiek June 2002 GEOSCIENCE LTD 620 Marindustry Drive San Diego, California 92121

More information

WITH LOW EMISSIVITY GLASS

WITH LOW EMISSIVITY GLASS WITH LOW EMISSIVITY GLASS Quebec Version 1.1 tel. : 1 800 463-2810 and fax : 418 687-0804 Version 1.1 tel. : 1 800 463-2810 and fax : 418 687-0804 VA TRANSMITTANCE GROUP 1 / LOW-E POSITION 2 (Lower heat

More information

Thermal Breakage Prediction

Thermal Breakage Prediction Thermal Breakage Prediction The prediction of glass breakage due to thermal stress is an important analysis for the longevity of a window. Thermal breakage occurs when there is a large temperature differential

More information

ResearcH JournaL 2009 / VOL 01.01. www.perkinswill.com

ResearcH JournaL 2009 / VOL 01.01. www.perkinswill.com ResearcH JournaL 2009 / VOL 01.01 www.perkinswill.com PERKINS+WILL RESEARCH JOURNAL / VOL 01.01 05. CONTEXT BASED DESIGN OF DOUBLE SKIN FACADES Climatic Considerations During the Design Process Ajla Aksamija,

More information

Residential Windows, 3 rd edition Corrected index 1

Residential Windows, 3 rd edition Corrected index 1 Residential Windows, 3 rd edition Corrected index 1 A absorptance definition, 78 determinants of, 78 79 energy performance and, 78 tinted glass, 84 acoustical properties of windows, 60 61 acrylic glazing

More information

CHAPTER 3 Window design for day lighting, ventilation and to

CHAPTER 3 Window design for day lighting, ventilation and to for day lighting CHAPTER 3 Window design for day lighting 3.1 Guideline: for day lighting 3.2 Mandatory clause 3.2.1 For air-conditioned buildings!"!#$$%& # '()!!"!#$$%& * '()! #!"!#$$% Table 3.2.1: Vertical

More information

Evaluation of Window Energy Rating Models for Different Houses and European Climates

Evaluation of Window Energy Rating Models for Different Houses and European Climates Evaluation of Window Energy Rating Models for Different Houses and European Climates J. and A. Roos Department of Materials Science, The Ångström Laboratory Uppsala University P.O. Box 534, S-751 21 Uppsala

More information

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi Climate and Energy Responsive Housing in Continental Climates The Suitability of Passive Houses for Iran's Dry and Cold Climate Farshad Nasrollahi Table of Contents Abstract German Abstract Introduction

More information

THERMAL LOSSES Thermal Losses Calculations

THERMAL LOSSES Thermal Losses Calculations Calculations -1- THERMAL LOSSES Thermal Losses Calculations Employer : 4M SA Project Location : ASHRAE Office Room : Example from ASHRAE 2013 Handbook - Fundamentals : Chapter 18, Single Room Example Peak

More information

Elegance SC. Solar Control

Elegance SC. Solar Control Elegance SC Solar Control Sapa Building System Building Understanding In an age of global warming, the reduction of carbon emissions is a key factor when both selecting materials for a building and how

More information

ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):

ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM): ENERGY AUDIT Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM): Leonard Fernandes DERBIGUM project reference : UAE -2014 - EA 103 Author : Daniel Heffinck (DERBIGUM)

More information

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Dienstleistung. Certification as Quality Approved Passive House Criteria for Residential-Use Passive Houses Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality

More information

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS Saim Memon Philip C. Eames Centre for Renewable Energy Systems

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric

More information

Environmentally Controlled Dynamic Glazing. Christopher D. Anderson, Ph.D. Pleotint, LLC

Environmentally Controlled Dynamic Glazing. Christopher D. Anderson, Ph.D. Pleotint, LLC Environmentally Controlled Dynamic Glazing Christopher D. Anderson, Ph.D. Pleotint, LLC Commercial Dynamic Glazing Landscape Electronically Controlled Voltage induces a color change Environmentally Controlled

More information

Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer

Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Pilkington Activ self-cleaning glass. The clear choice for your conservatory. The Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories bringing

More information

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E.

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E. A Methodology to Develop a Sustainable, High Performance Building Envelope BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E. We re Going To Reveal New Sustainable Truths and Expose Old Bogus Truths We

More information

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions. In Townsville s climate it is essential to choose building materials that perform well in our local conditions. Choosing the correct materials and insulation will improve the overall thermal performance

More information

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS - pcoolingandheating COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS - Bjarne W. Olesen, Ph.D. D. F. Liedelt "Velta" Summary Due to intensive use of

More information

IDA Early Stage Building Optimization (ESBO) User guide

IDA Early Stage Building Optimization (ESBO) User guide IDA Early Stage Building Optimization (ESBO) User guide Version 1.09, Oct 2013 2 Contents What is IDA ESBO?... 4 How do I use IDA ESBO?... 4 IDA ESBO user interface... 7 Rooms tab... 7 Building tab...

More information

RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof.

RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof. RosevilleProject Glass Products You can reduce your cooling energy usage by 25% or more. Here is the proof. Hot-Button Issues Residents of California, Arizona, and Nevada don t need a weather forecast

More information

How To Design A Room Air Conditioning System

How To Design A Room Air Conditioning System Comparison of HVAC Technology in Buildings Conventional HVAC Technology Bauer Optimising Technology The Differences Room environment (Occupant Comfort) Energy Consumption Architecture Air flows in a room

More information

ENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS

ENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS ENERGY AUDITS IN DWELLING BUILDINGS IN LATVIA. DATA ANALYSIS SUMMARY D. BLUMBERGA*, A. BLUMBERGA, V. VITOLINS Riga Technical University Kronvalda bulvaris 1, LV1010, Riga, Latvia [email protected] Tel.: +

More information

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

Holistic Approach in Delivering Government Buildings The Low Carbon Concept International Conference on Planning for Low Carbon Cities 22 May 2009 Holistic Approach in Delivering Government Buildings The Low Carbon Concept Ir. HO Sai-king, Assistant Director (Building Services),

More information

The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study

The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study WARAPORN RATTANONGPHISAT 1,2,*, FEDERICO M. BUTERA 2, R.S. ADHIKARI 2 AND CHALERMPORN YOOPRATETH

More information

Sino-Italian Environment & Energy Building S I E E B

Sino-Italian Environment & Energy Building S I E E B MOST Ministry of Science and Technology Republic of China Sino-Italian Environment & Energy Building S I E E B Concept The Sino-Italy Environment & Energy Building (SIEEB) is an intelligent, ecological

More information

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Exemplary Retrofitting of an Old School in Stuttgart - EROS - Exemplary Retrofitting of an Old School in Stuttgart - EROS - City of Stuttgart, Summary The objective of the project was to demonstrate the potentials of a retrofitting process for a typical school in

More information

Sun-Activ - reflective SBS membrane. Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof

Sun-Activ - reflective SBS membrane. Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof Sun-Activ - reflective SBS membrane Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof Sun-Activ - reflective SBS membrane Icopal and the environment Icopal is committed to the

More information

Software Development for Cooling Load Estimation by CLTD Method

Software Development for Cooling Load Estimation by CLTD Method IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 2278-1684Volume 3, Issue 6 (Nov. - Dec. 2012), PP 01-06 Software Development for Cooling Load Estimation by CLTD Method Tousif Ahmed Department

More information

Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance

Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance Steve Gasworth and Triloka Tankala SABIC Innovative Plastics [email protected] [email protected]

More information

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010 EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a

More information

THE EUROPEAN GREEN BUILDING PROGRAMME. Building Envelope Technical Module

THE EUROPEAN GREEN BUILDING PROGRAMME. Building Envelope Technical Module THE EUROPEAN GREEN BUILDING PROGRAMME Building Envelope Technical Module Contents 1. Introduction...1 2. Inventory of systems...2 3. Assessment of energy saving technical measures...4 4. Action Plan...12

More information

Energy Savings with Window Retrofits

Energy Savings with Window Retrofits Center for Energy and Environment Energy Savings with Window Retrofits Presentation to Energy Design Conference & Expo Duluth, MN February 25, 2014 Agenda v Background v Introduction: What are window retrofits?

More information

Solar shading for low energy buildings

Solar shading for low energy buildings Solar shading for low energy buildings FEBRUARY 2012 Edition 1 How shutters and blinds reduce the energy needs of buildings and improve their thermal and visual comfort MEMBERS OF THE ES-SO TECHNICAL COMMITTEE

More information

Integrated Solar Radiant Systems

Integrated Solar Radiant Systems Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant

More information

Could a European Super Energy Efficient Standard Be Suitable for the U.S.?

Could a European Super Energy Efficient Standard Be Suitable for the U.S.? Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS Inc., Pittsburgh, PA Abstract The European Passive House residential energy efficiency standard has produced

More information

Glass partitions SFB 3074

Glass partitions SFB 3074 Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use

More information

Perspective-Dependent Color-Changing Roofing Sheets

Perspective-Dependent Color-Changing Roofing Sheets Perspective-Dependent Color-Changing Roofing Sheets Anthony Cartwright, Joseph Karas, Steven McCarthy, Brian Paige Saint Gobain Student Design Competition, 3/24/2010 Project Summary: Direct natural sunlight

More information

ENERGY PERFORMANCE MODELLING AND HEAT RECOVERY UNIT EFFICIENCY ASSESSMENT OF AN OFFICE BUILDING

ENERGY PERFORMANCE MODELLING AND HEAT RECOVERY UNIT EFFICIENCY ASSESSMENT OF AN OFFICE BUILDING THERMAL SCIENCE: Year 2015, Vol. 19, No. 3, pp. 865-880 865 ENERGY PERFORMANCE MODELLING AND HEAT RECOVERY UNIT EFFICIENCY ASSESSMENT OF AN OFFICE BUILDING by Norbert L. HARMATI a*, Radomir J. FOLI] a,

More information

Solar Heating Basics. 2007 Page 1. a lot on the shape, colour, and texture of the surrounding

Solar Heating Basics. 2007 Page 1. a lot on the shape, colour, and texture of the surrounding 2007 Page 1 Solar Heating Basics Reflected radiation is solar energy received by collectorsfrom adjacent surfaces of the building or ground. It depends a lot on the shape, colour, and texture of the surrounding

More information