1 4 (#2) , Thermally Toughened Heat and Solar Control Glass 1 (C) (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics 0,40/0,28/0,29 : No Performance Determined

2 4 (#2) , Thermally Toughened Heat and Solar Control Glass 1 (C) (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics 0,40/0,28/0,29 : No Performance Determined

3 6 (#2) , Thermally Toughened Heat and Solar Control Glass 1 (C) (-2; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,70/0,10/0,11 Solar energy characteristics 0,38/0,25/0,29 : No Performance Determined

4 6 (#2) , Thermally Toughened Heat and Solar Control Glass 1 (C) (-2; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,70/0,10/0,11 Solar energy characteristics 0,38/0,25/0,29 : No Performance Determined

5 6 (#2) , Thermally Toughened Heat and Solar Control Glass 1 (C) (-2; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,70/0,10/0,11 Solar energy characteristics 0,38/0,25/0,27 : No Performance Determined

6 6 (#2) , Thermally Toughened Heat and Solar Control Glass 1 (C) (-2; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,70/0,10/0,11 Solar energy characteristics 0,38/0,25/0,27 : No Performance Determined

7 6 (#2) , Thermally Toughened Heat and Solar Control Glass 1 (C) (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,69/0,10/0,11 Solar energy characteristics 0,37/0,25/0,26 : No Performance Determined

8 6 (#2) , Thermally Toughened Heat and Solar Control Glass 1 (C) (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,69/0,10/0,11 Solar energy characteristics 0,37/0,25/0,26 : No Performance Determined

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5 4 (#2) - 12-4, Thermally Toughened ISS114 #2 + Dry Air (%100) + Clear 1(C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 2,6 W / (m 2 K) Light transmission and reflection 0,14/0,34/0,37 Solar energy

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Argon (90%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4-12 - 4 (#3), Thermally Toughened Helio Blue + Dry Air (100%) + 1(C)3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,58/0,/0,10 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4-12 - 4 (#3), Clear Float Glass + Argon (90%) +Heat Control Glass 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 6 (#1) - 12-4 (#3), Thermally Toughened Tentesol T Blue #1 + Dry 1(C)2-12 - 6-12 - 4 32 (-2; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,34/0,34/0,18 Solar energy characteristics

More information

EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)

EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356) 4 (# 2) - 12-33.1, Heat Control Glass (Low-E #2) + Argon (90%) + Pendulum body impact resistance - 12-2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection

More information

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5 4-12 - 33.1, Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1(C)3-12 - 2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 2,8 W / (m 2 K) Light transmission and reflection

More information

SELECTIVE GLAZING FOR SUN CONTROL

SELECTIVE GLAZING FOR SUN CONTROL SUN CONTROL GLAZING SELECTIVE GLAZING FOR SUN CONTROL Sun Factor 1st level performance for direct solar energy Solar energy control Solar control coating Only if the glass is exposed to sun rays! 2nd level

More information

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the

More information

Unbeatable energy efficient glass curtain wall system

Unbeatable energy efficient glass curtain wall system Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics

More information

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND

More information

Solar Energy: The Power of the Sun by Kelly Hashway

Solar Energy: The Power of the Sun by Kelly Hashway We all know the sun is important. It provides for plants, animals, and people here on Earth. But how does the sun do that? It s the sun s energy that makes life on our planet possible. Energy from the

More information

What is Solar Control?

What is Solar Control? A better environment inside and out. Solar, Safety and Security Window Films: Tech Bulletin Understanding Solar Performance Solar Gard solar control window films use advanced technology to benefit consumers

More information

CE Marking of Glass products

CE Marking of Glass products CE Marking of Glass products INTRODUCTION... 10 ARTLITE... 11 ARTLITE / ARTLITE DIGITAL HEAT STRENGTHENED... 12 ARTLITE / ARTLITE DIGITAL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 1 ARTLITE

More information

Linear thermal transmittance of the assembly of the glazing and the frame in windows

Linear thermal transmittance of the assembly of the glazing and the frame in windows Linear thermal transmittance of the assembly of the glazing and the frame in windows Svend Svendsen,Professor, Technical University of Denmark; ss@byg.dtu.dk; www.byg.dtu.dk Jacob B. Laustsen, Assistant

More information

WINDOW FILM. Buyer s Guide

WINDOW FILM. Buyer s Guide WINDOW FILM Buyer s Guide Improve Your Windows Window film can do more than simply block out the sun. The benefits of window film can improve your home, increase your comfort and help you enjoy your home

More information

iku windows the intelligent self cleaning window AUTOMATIC system

iku windows the intelligent self cleaning window AUTOMATIC system iku windows is a aluminium sliding window system with two rails and double thermal breakage. By adding the iku box underneath the window sill it becomes an intelligent window. Functions Automatic opening

More information

Selecting Energy Efficient New Windows in Florida

Selecting Energy Efficient New Windows in Florida Selecting Energy Efficient New Windows in Florida www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified

More information

LBNL WINDOW 6 AND OPTICS 6 PROCEDURES TO COMPUTE THE SOLAR / OPTICAL PERFORMANCE OF NEW PRODUCTS AND LAMINATED GLASS

LBNL WINDOW 6 AND OPTICS 6 PROCEDURES TO COMPUTE THE SOLAR / OPTICAL PERFORMANCE OF NEW PRODUCTS AND LAMINATED GLASS Technical Bulletin ATS-171 TO COMPUTE THE SOLAR / OPTICAL PERFORMANCE OF NEW PRODUCTS AND LAMINATED GLASS Notes on Window and Optics 6 Programs Window 6 and Optics 6 programs are available free from LBNL

More information

Selecting Energy Efficient New Windows in California

Selecting Energy Efficient New Windows in California Selecting Energy Efficient New Windows in California www.efficientwindows.org Janurary 016 Zones 1. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are

More information

Integral Shading & Privacy Solutions

Integral Shading & Privacy Solutions Integral Shading & Privacy Solutions Manual Magnetic Blinds Betweenglassblinds offer a versatile and contemporary means of privacy and shading suitable for large door panels, screens, office partitioning,

More information

Selecting Energy Efficient New Windows in Texas

Selecting Energy Efficient New Windows in Texas Selecting Energy Efficient New Windows in Texas www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified

More information

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace HEAT GAINS and LOSSES : ROOFS and WALLS Wall Roof Ts To Ts To Ti Ceiling/Airspace Ti Roof and wall are analyzed in the same way. In winter the heat loss is simple transmission based on the inside and outside

More information

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd. Double Glazing Glass Energy Saving Solutions Harris Silicones & Glass (Pvt.) Company Introduction Pioneers of Silicone Sealants in Pakistan Manufacturing in collaboration with Momentive Performance Materials

More information

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001 NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)

More information

Improving thermal insulation of concrete sandwich panel buildings

Improving thermal insulation of concrete sandwich panel buildings Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general

More information

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001 NO. HU-DOP_TD-25_001 Product type TD 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-35_001 Product type TD 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-45_001 Product type TD 3,5x45 mm EN 14566:2008+A1:2009

More information

Translucent Facades. Express your creativity start planning with Rodeca. Aesthetics Functionality Efficiency

Translucent Facades. Express your creativity start planning with Rodeca. Aesthetics Functionality Efficiency Translucent Facades Express your creativity start planning with Rodeca Aesthetics Functionality Efficiency ade by Rodeca Translucent facades Facades reflect in many ways the function of clothing. They

More information

Selecting Energy Efficient Replacement Windows in Nevada

Selecting Energy Efficient Replacement Windows in Nevada Selecting Energy Efficient Replacement Windows in Nevada www.efficientwindows.org January 06 STAR Zones. Meet the Energy Code & Look for the STAR Windows must comply with your local energy code. Windows

More information

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Self-cleaning Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories

More information

Selecting Energy Efficient New Windows in Georgia

Selecting Energy Efficient New Windows in Georgia Selecting Energy Efficient New Windows in Georgia www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.

More information

Selecting Energy Efficient New Windows in Arizona

Selecting Energy Efficient New Windows in Arizona Selecting Energy Efficient New Windows in Arizona www.efficientwindows.org January 016 ENERGY STAR Zones 1. Meet the Energy Code & Look for the ENERGY STAR Windows must comply with your local energy code.

More information

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31. Uniclass L411 +L413:P7114 EPIC D11 +D13:X725 CI/SfB (31.4)+(31.5) Xn6 9/11 SmartSash A BRAND OF THE VEKA UK GROUP Specification Guide Fenestration Solutions for Public Sector & Commercial Applications

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

WITH LOW EMISSIVITY GLASS

WITH LOW EMISSIVITY GLASS WITH LOW EMISSIVITY GLASS Quebec Version 1.1 tel. : 1 800 463-2810 and fax : 418 687-0804 Version 1.1 tel. : 1 800 463-2810 and fax : 418 687-0804 VA TRANSMITTANCE GROUP 1 / LOW-E POSITION 2 (Lower heat

More information

Tech Bulletin. Understanding Solar Performance

Tech Bulletin. Understanding Solar Performance Tech Bulletin Understanding Solar Performance Bekaert solar control window films use advanced technology to benefit consumers with quality solutions that enhance comfort and decrease energy use. By understanding

More information

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Pilkington Activ The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Thermal insulation. When it comes to conservatories, we think

More information

Double Glazed Units. Self-cleaning action Let nature do the work

Double Glazed Units. Self-cleaning action Let nature do the work slimlite Self-cleaning Double Glazed Units Self-cleaning glass the latest permanent Hydrophobic Nanostructure innovation for Slimlie Double Glazed Units TEN YEAR GUARANTEE slimlite Double Glazed Units

More information

SCHOTT PYRANOVA Planline System

SCHOTT PYRANOVA Planline System Schott_050_Pyranova_E_RZ.fh8.07.005 0:50 Uhr Seite HOME T E C H The Planline system The patented glass fixing method is a clear multi- is based on a fire resistant double glazed allows quick and easy replacement

More information

Constructions Database User Guide <Virtual Environment> 5.9

Constructions Database User Guide <Virtual Environment> 5.9 Constructions Database User Guide 5.9 Page 1 of 35 Contents 1. Introduction...3 2. Units...4 3. Main Dialogue Project Constructions...5 3.1. Outline...5 3.2. Construction Classes

More information

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Self-Cleaning The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Conservatories bringing the outside in. Pilkington Activ has made

More information

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products

Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products 10 reasons for an energy labeling system (1/2) The buildings sector is responsible for a considerable share of final

More information

The GLASSX crystal method of functioning.

The GLASSX crystal method of functioning. The GLASSX crystal method of functioning. GLASSXcrystal integrates 4 system components in a functional unit: transparent heat insulation, protection from overheating, energy conversion and thermal storage.

More information

Series 456 Commercial Awning Window

Series 456 Commercial Awning Window Commercial Awning Window COMMERCIAL SERIES Photo courtesy of Hanlon Windows Australia DATE: MAY 2013 REPLACES: MARCH 2008 COMMERCIAL SERIES KEY FEATURES/PERFORMANCE CHARACTERISTICS Scale: not to scale

More information

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE LOW-E GLASS TECHNICAL GUIDE SELECTIVE INFRARED RADIATION FILTER Infrared radiation coming from natural sun light can cause a heat build-up inside building; This situation leads to thermal imbalance during

More information

Windows are one of the most important components of a

Windows are one of the most important components of a design concepts Arjun Kamal MAKING BETTER INDOOR ENVIRONMENTS WITH ENERGY-EFFICIENT WINDOW DESIGN An insight into the various technologies used for constructing windows, and an attempt at understanding

More information

Lead architect: Ron Arad Architects - Executive architect: Jaspers & Eyers

Lead architect: Ron Arad Architects - Executive architect: Jaspers & Eyers SOLUTIONS FOR SUSTAINABLE BUILDINGS THE GUIDE TO BREEAM Lead architect: Ron Arad Architects - Executive architect: Jaspers & Eyers Reynaers develops innovative and sustainable aluminium solutions, for

More information

Testing Rules for Thermal Conductivity October 2015

Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity (October 2015) 1 Normative references (to be inserted as additional chapter in the Testing Rules for Panels) 1.

More information

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Pilkington Activ self-cleaning glass. The clear choice for your conservatory. The Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories bringing

More information

Minergie and Minergie-P, the Swiss Energy Labels Armin Binz, Institute of Energy in Building

Minergie and Minergie-P, the Swiss Energy Labels Armin Binz, Institute of Energy in Building Minergie and MinergieP, the Swiss Energy Labels Armin Binz, Institute of Energy in Building Energy and Sustainability from Concepts to Labels Concepts Methods and Instruments Standards and Labels SIA 8/,

More information

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector NOW AVAILABLE! the new ASW-58A-22/30 Solar Thermal Collector The ASW-58A-22/30 series of collectors are available in 22 and 30 tube units. Other sizes are available upon request. Each unit comes complete.

More information

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Dienstleistung. Certification as Quality Approved Passive House Criteria for Residential-Use Passive Houses Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality

More information

Building Standards Conservatory Roofs Meeting 28 Nov 2012

Building Standards Conservatory Roofs Meeting 28 Nov 2012 Conservatory Roofs Meeting 28 Nov 2012 Reason for hosting this meeting Availability of new roofing systems Increasing popularity in changing from transparent to opaque roof finishes Lack of clarity and

More information

ENERGY LABELLING OF GLAZINGS AND WINDOWS IN DENMARK: CALCULATED AND MEASURED VALUES

ENERGY LABELLING OF GLAZINGS AND WINDOWS IN DENMARK: CALCULATED AND MEASURED VALUES Pergamon P II: S0038 09X(0)00031 Solar Energy Vol. 73, No. 1, pp. 3 31, 00 00 Elsevier Science Ltd All rights reserved. Printed in Great Britain 0038-09X/0/$ - see front matter www.elsevier.com/ locate/

More information

Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability

Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability Florian Speier Swiss Architect CPHC co-founder, Zola European Windows What makes a window perform?

More information

Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer

Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code

More information

GLASSX crystal The glass that stores, heats and cools.

GLASSX crystal The glass that stores, heats and cools. GLASSX crystal The glass that stores, heats and cools. The GLASSX crystal method of functioning GLASSX crystal integrates 4 system components in a functional unit: transparent heat insulation, protection

More information

Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance

Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance Significance of Glazing Thermal Conductivity for MAC Indirect Emissions and EV Battery Performance Steve Gasworth and Triloka Tankala SABIC Innovative Plastics sgasworth@exatec.biz steven.gasworth@sabic.com

More information

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

ENEA Thermodynamic Solar Project. Prepared by Mauro Vignolini Presented by A. Fontanella Italy China Innovation Forum - November 8, 2010

ENEA Thermodynamic Solar Project. Prepared by Mauro Vignolini Presented by A. Fontanella Italy China Innovation Forum - November 8, 2010 ENEA Thermodynamic Solar Project Prepared by Mauro Vignolini Presented by A. Fontanella ENEA objective To produce electricity by solar plant at high temperature (550 C) using molten salt. the advantages

More information

3 i Window Films. 3 Proof of Technology Experiment Cover Letter

3 i Window Films. 3 Proof of Technology Experiment Cover Letter 3 i Window Films 3 Proof of Technology Experiment Cover Letter This Proof of Technology experiment was conducted at a large office facility with 10 stories. The experiment was conducted in adjacent offices

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

Adaptive strategies for office spaces in the UK climate

Adaptive strategies for office spaces in the UK climate International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate

More information

Ecofys VII U-Values for Better Energy Performance of Buildings

Ecofys VII U-Values for Better Energy Performance of Buildings Ecofys VII U-Values for Better Energy Performance of Buildings Quantifying the potential I II III IV & V VI Climate Protection Regulation Cost Effectiveness Enlarged EU Price Scenario Key figures from

More information

Determination of boundary conditions for passive schools : impact on heating and cooling demand

Determination of boundary conditions for passive schools : impact on heating and cooling demand Determination of boundary conditions for passive schools : impact on heating and cooling demand Authors: Barbara Wauman 1,2, Jeroen Poppe 3, Stefan Van Loon 3, Ralf Klein 1, Kristien Achten 4, Hilde Breesch

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING R.M.J. Bokel Department of Architecture, Delft Technical University, Delft, The Netherlands,

More information

Introduction to solar thermal technology

Introduction to solar thermal technology Introduction to solar thermal technology M.Sc. Research and Testing Centre for Thermal Solar Systems (TZS) Institute for Thermodynamics and Thermal Engineering (ITW) University of Stuttgart Pfaffenwaldring

More information

4 Insulating Glazing Terminology

4 Insulating Glazing Terminology 4 59 4 60 Definition of insulating glazing Insulating glazing has been around for about 60 years. The oldest patent on this subject actually originates from the year 1865. The official definition of the

More information

Florida Building Code, 5th Edition (2014) June 30 th, 2015

Florida Building Code, 5th Edition (2014) June 30 th, 2015 Florida Building Code, 5th Edition (2014) Update June 30 th, 2015 FBC Update, 5 th Edition (2014) Uses 2012 ICC as its Base Code as required by Florida Legislature Causing sections to be changed Books

More information

STANDARD EXTRUDED HEAT SINKS

STANDARD EXTRUDED HEAT SINKS STANDARD EXTRUDED HEAT SINKS ABHA101 Weight: 0.4oz (11.34g) ABHA102 Weight: 0.5oz (14.17g) STANDARD EXTRUDED HEAT SINKS ABHA103 Weight: 0.2oz (5.57g) For use with DIPs and SRAMs ABHA104 Weight: 0.1oz (2.83g)

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

ModernView. The Brickmold Designer Series. The Brickmold Designer Series. TheBrickmoldDesignerSeries. Outside the ordinary.

ModernView. The Brickmold Designer Series. The Brickmold Designer Series. TheBrickmoldDesignerSeries. Outside the ordinary. Page 1 rickmold rickmoldseries Outside the ordinary. New Construction Double-Hung & Single-Hung Vinyl Windows 300 100 Our windows are NFRC-rated, certified, and labeled for both U-factor and solar heat

More information

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope STEEL BUILDINGS IN EUROPE Single-Storey Steel Buildings Part 8: Building Envelope Single-Storey Steel Buildings Part 8: Building Envelope 2 - ii Part 8: Building Envelope emissions

More information

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE Energy and Sustainability 287 Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE M. A. Haggag UAE University, United Arab Emirates Abstract The city of Dubai,

More information

Energy audit in Finland

Energy audit in Finland Energy audit in Finland NorTech Oulu Lauri Mikkonen Energy Audit in Finland An energy audit tells about the energy efficiency and total energy consumption in a building, including all consumed heating,

More information

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1 Opening the Bonnet Prof Darren Woolf WYSINWYG 1 WYSINWYG What You See Is NOT What You Get: Looking inside the Pandora s Box Prof Darren Woolf WYSINWYG 2 WYSIWYG implies a user interface that allows the

More information

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

ROTEX gas hybrid heat pump. A strong team.

ROTEX gas hybrid heat pump. A strong team. ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat

More information

Building Audit. October 1, 2009 Frank Schipper

Building Audit. October 1, 2009 Frank Schipper Building Audit October 1, 2009 Frank Schipper Algemeen Quality control Accreditation commission Certification institute BRL 9500 EP consultant Certificate Clients 2 type of advice Energy certificate Energy

More information

SKY-TILE SKY-TILE. Daylight Consultants web: www.espaciosolar.com blog: espaciosolar.blogspot.com. Bioclimatic Modular Skylights

SKY-TILE SKY-TILE. Daylight Consultants web: www.espaciosolar.com blog: espaciosolar.blogspot.com. Bioclimatic Modular Skylights DEPLOSUN DEPLOSUN is a modular glazing system that has a selective solar factor in relation with solar possition.this system is to be used in horizontal skylights. It is composed by a tempered T 6mm. glass

More information

HOUSE BILL No. 1423. Koch, VanNatter

HOUSE BILL No. 1423. Koch, VanNatter *HB1423.1* January 28, 2014 HOUSE BILL No. 1423 DIGEST OF HB 1423 (Updated January 27, 2014 9:54 am - DI 103) Citations Affected: IC 8-1. Synopsis: Allows the owner of a private generation project to sell

More information

ENERGY SMARTS: ENERGY EFFICIENT WINDOWS

ENERGY SMARTS: ENERGY EFFICIENT WINDOWS Practical solutions for a complex world. ENERGY SMARTS: ENERGY EFFICIENT WINDOWS Leona K. Hawks, Professor Extension Specialist Housing & Environment College of Natural Resources Utah State University

More information

Portuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System

Portuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System Portuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System Manuel Casquiço/ ADENE Tabula Expert Workshop - Energy Assessment of National

More information

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows

The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows by The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows In Alliance with OCCUPANT COMFORT All of the windows above have the same exterior tint of glass. Why such a

More information

BUILDING ENERGY DEMAND AGGREGATION AND SIMULATION TOOLS A DANISH CASE STUDY

BUILDING ENERGY DEMAND AGGREGATION AND SIMULATION TOOLS A DANISH CASE STUDY BUILDING ENERGY DEMAND AGGREGATION AND SIMULATION TOOLS A DANISH CASE STUDY P. Gianniou; A. Heller; C. Rode Department of Civil Engineering, Technical University of Denmark, Kgs. Lyngby ABSTRACT Nowadays,

More information

How To Test A Base Axe

How To Test A Base Axe Scotch-Weld DP760 Product Data Sheet Updated : February 2009 Supersedes: June 2001 Product Description DP760 epoxy adhesive is a non-sag, two-part room temperature curing adhesive designed for use when

More information

FABRIC ENERGY EFFICIENCY FOR PART L 2013

FABRIC ENERGY EFFICIENCY FOR PART L 2013 Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub

More information

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ Ref. No: 12/02870/FULM Contents 1. General... 2 2. Planning Condition... 2 3. Development...

More information

How Do I Claim Federal and North Carolina Tax Credits for My Renewable Energy System?

How Do I Claim Federal and North Carolina Tax Credits for My Renewable Energy System? How Do I Claim Federal and North Carolina Tax Credits for My Renewable Energy System? If you have recently purchased a renewable energy system, such as a solar photovoltaic (PV), a solar thermal heating

More information

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Passiv Haus Institut. Certification as Quality Approved Passive House Criteria for Residential-Use Passive Houses Passiv Haus Institut Dr. Wolfgang Feist Rheinstr. 44/46 D-64283 Darmstadt www.passiv.de Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses Passive Houses are

More information

Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows

Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows By Steve DeBusk, CEM, CMVP Global Energy Solutions Manager CPFilms, a Subsidiary of Solutia Inc. Abstract Energy

More information

Innovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents

Innovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents Innovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents Innovative solution for heat recovery of ventilation air in older apartment

More information

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015 www.zebra2020.eu Delivering on innovation and market uptake. Best-in-cases of nzeb Ramon Pascual Bucharest May 8th, 2015 Outline nzeb Database Best in cases of nzeb Climates in Europe Preliminary results

More information

PHOTOVOLTAIC GLASS STUDY

PHOTOVOLTAIC GLASS STUDY PHOTOVOLTAIC GLASS STUDY - Vindico PV+ - Glass solutions for increasing photovoltaic productivity (patent pending) Vindico PV+ (patent pending) Simple Steps leading to Simply Amazing Results Increasing

More information

Impact-Resistant Windows and Sliding Glass Doors

Impact-Resistant Windows and Sliding Glass Doors Impact-Resistant Windows and Sliding Glass Doors Make Your Home A SafeHarbor. SafeHarbor Impact-Resistant Windows and Sliding Glass Doors are designed to look like traditional windows and doors, but they

More information