Testing Rules for Thermal Conductivity October 2015
|
|
|
- Neal King
- 10 years ago
- Views:
Transcription
1 Testing Rules for Thermal Conductivity October 2015
2 Testing Rules for Thermal Conductivity (October 2015) 1 Normative references (to be inserted as additional chapter in the Testing Rules for Panels) 1. EN Self-supporting double skin metal faced insulating panels - Factory made products Specifications 2. EN Thermal insulating products. Evaluation of conformity 3. EN ISO Building materials and products. Hygrothermal properties - Tabulated design values and procedures for determining declared and design thermal values (replacing EN 12524) 4. Product standards for core materials: EN Thermal insulation products for buildings Factory made mineral wool (MW) products Specification EN Thermal insulation products for buildings Factory made expanded polystyrene (EPS) products Specification EN Thermal insulation products for buildings Factory made extruded polystyrene foam (XPS) products Specification EN Thermal insulation products for buildings Factory made rigid polyurethane foam (PU) products Specification 5. EN ISO Thermal bridges in building construction Heat flows and surface temperatures Part 1: Detailed calculations (ISO 10211) 6. ISO 9001 Quality management systems Requirements For all standards mentioned, the last version published in the Official Journal of the European Union (OJEU) is the basis of these Testing Rules.
3 Testing Rules for Thermal Conductivity (October 2015) 2 Determination of the thermal conductivity based on EN 14509, and A.10 The declared thermal conductivity shall be determined in accordance with the procedures described in the appropriate product standard for the core material in the direction used for insulation in the sandwich panel. For preformed CE-marked mineral wool core materials, the values and the results from the manufacturer of the core material can be used without any further testing, if the manufacturer has a quality system that respects the requirements of EN 13172, the CE markings provide the λ values for the orientation used in the panel manufacturing process and these core material performances are controlled under responsibility of a third party, in AVCP system 1+ (EPAQ system A of PPA-Europe). For other materials than core materials (e.g. metal sheets), tabulated values in accordance with EN shall be used. The declared thermal conductivity (λ Declared) and the design value of the thermal conductivity (λ Design) shall be determined. In case of aged values, λ Declared is equal to λ Design (if not stated otherwise). Afterwards, the thermal transmittance value (UdS) for the panel system excluding the transversal joints, but taking into account the effects of the longitudinal joints, shall be calculated according to EN Above note that λ Design is a national choice. General procedure (process chart) Determination of thermal conductivity Manufacturer: testing 4 samples of different batches Basic testing / ITT Accepted notified (test) laboratory 1) : testing 4 samples of the same batches as the manufacturer Manufacturer: additional testing of minimum 6 samples from other batches Independent Expert has to compare the test results and then to make the statistical evaluation considering the ITT values from manufacturer and accepted notified (test) laboratory 1) λ Declared 1) Accepted by PPA-Europe for thermal conductivity testing. As there are no notified bodies for thermal characteristics in case of EN 14509, the tests can be performed by notified bodies for testing the thermal conductivity of PU according to EN 13165, of MW according to EN 13162, of EPS according to EN or of XPS according to EN 13164, from the list of third parties accepted by PPA-Europe for thermal conductivity testing.
4 Testing Rules for Thermal Conductivity (October 2015) 3 The declared thermal conductivity (λ Declared) shall be determined in accordance with the procedures described in the appropriate product standard for the core material. A. Test procedure for panels with PU core: The method according to Fixed increment procedure shall be used (for core material with CO2 as propellant, additional requirements have to be respected). 1. Basic Testing / ITT: a. Initial λ-test: 4 samples 20 mm thick or a variety of different thicknesses by agreement with the accepted notified (test) laboratory, cut out of the center of panels from different productions and thicknesses, without cover sheets, have to be tested in the same time by the manufacturer and by an accepted notified (test) laboratory from the list of third parties accepted by PPA-Europe for thermal conductivity testing. The manufacturer has to manage the coordination of the parallel testing. b. Normality-test: the same 4 samples have to be tested by an accepted notified (test) laboratory, after aging 21 days at 70 C. 2. Additional Testing: The manufacturer has to perform 6 more λ-tests on different batches. 3. Comparing of the test results by an Independent Expert: a. The difference between the λ-values of the manufacturer and the accepted notified (test) laboratory shall be within the tolerances given in Table 1. b. If the difference of all 4 single λ-values after aging 21 days at 70 C is lower than 6mW/(m*K), the fixed increment can be used. Evaluation of the test results by an Independent Expert: Number of tests: a. Fixed increment procedure: λ ini + fixed increment b. Statistical evaluation delivers λ 90/90 c. Rounding rules λ Declared 4 samples of different batches have to be tested by the manufacturer. Simultaneously another 4 samples of the same 4 batches have to be tested by a European accepted notified (test) laboratory from the list of third parties accepted by PPA-Europe for thermal conductivity testing. The manufacturer has to test another 6 samples from different batches to complete the 10 results for the ITT test. The Independent Expert has to control that the results of the manufacturer and the results of the accepted notified (test) laboratory are equal. Otherwise, the reason for the different results has to be eliminated and the tests may have to be repeated. The EPAQ Independent Expert has also to control
5 Testing Rules for Thermal Conductivity (October 2015) 4 if the test results of the normality test fulfill the requirements for the normality test. Following, the Independent Expert has to determine the declared thermal conductivity (λ Declared) and the design value (λ Design). These values have to be used by the Independent Expert to calculate the U-values (Uds) for the Certification Document and the threshold values for the FPC. Further running production: The manufacturer has to collect and document all results from his FPC (minimum once a month with possibility to test more). The single test results with the fixed increment have to be below the declared value. Furthermore, the results have to be added in the statistical evaluation to control that the newly calculated values of the thermal conductivity (λ Declared_new) and the design value (λ Design_new) are below or equal to the values of the initial type testing that are used for declaration on the CE-mark and for calculating the U-values (Uds). During each external third party control according to the Quality Regulations, a panel has to be taken out of the production and the thermal conductivity has to be tested in the laboratory of third party accepted by PPA-Europe. The single test results with the fixed increment have to be below or equal to the declared value, otherwise, the reason for the deviation has to be cleared and the tests have to be repeated or the declared values have to be changed. Furthermore the results have to be added in the statistical evaluation to control that the newly calculated values of the thermal conductivity (λ Declared_new) and the design value (λ Design_new) are below or equal to the values of the initial type testing that are used for declaration on the CE-mark and for calculating the U-values (Uds). If the test results of the manufacturer and/or the accepted notified (test) laboratory show permanent deviation from the declared thermal conductivity, the declared and design values as well as the U-values (Uds) have to be adjusted in the Certification Document by an Independent Expert. B. Test procedure for panels with MINERAL WOOL or EPS core: 1. Basic Testing / ITT: Initial λ-test: 4 samples 50 mm thick or thicker (20 mm thick in case 50 mm is not applicable for the manufacturer), cut out of the center of panels from different productions and thicknesses, without cover sheets or lamellas taken out before bonding with the steel sheets, have to be tested in the same time by the manufacturer and by an accepted notified (test) laboratory from the list of third parties accepted by PPA-Europe for thermal conductivity testing. The manufacturer has to manage the coordination of the parallel testing. Samples from MW slabs must be cut in such way so that they correspond to lamellas; the cutting direction (line direction or transversal direction) has to be noticed, because thermal conductivity is different.
6 Testing Rules for Thermal Conductivity (October 2015) 5 2. Additional Testing: The manufacturer has to perform 6 more λ-tests on different batches. 3. Comparing of the test results by an Independent Expert: The difference between the λ-values of the manufacturer and the accepted notified (test) laboratory shall be within the tolerances given in Table 1. Evaluation of the test results by an Independent Expert: Number of tests: a. Statistical evaluation delivers λ 90/90 b. Rounding rules λ Declared 4 samples of different batches have to be tested by the manufacturer. Simultaneously another 4 samples of the same 4 batches have to be tested by a European accepted notified (test) laboratory from the list of third parties accepted by PPA-Europe for thermal conductivity testing. The manufacturer has to test another 6 samples from different batches to complete the 10 results for the ITT test. The Independent Expert has to control that the results of the manufacturer and the results of the accepted notified (test) laboratory are equal. Otherwise, the reason for the different results has to be eliminated and the tests may have to be repeated. Following, the Independent Expert has to determine the declared thermal conductivity (λ Declared) and the design value (λ Design). These values have to be used by the Independent Expert to calculate the U-values (Uds) for the Certification Document and the threshold values for the FPC. In case the tests for thermal conductivity are performed by the manufacturer of the mineral wool, the manufacturer of the mineral wool has to be involved in the basic tests and has to test also 4 samples of the same batch as the accepted notified (test) laboratory and as or instead of the manufacturer of the panel. The manufacturer of the mineral wool has to follow the regulation of the EN Further running production: The manufacturer has to collect and document all results from his FPC (minimum once a month with possibility to test more). The single test results have to be below the declared value. Furthermore, the results have to be added in the statistical evaluation to control that the newly calculated values of the thermal conductivity (λ Declared_new) and the design value (λ Design_new) are below or equal to the values of the initial type testing that are used for declaration on the CE-mark and for calculating the U-values (Uds). Otherwise, the reason for the deviation has to be cleared and the tests have to be repeated or the declared values have to be changed. During each external third party control according to the Quality Regulations, a panel has to be taken out of the production and the thermal conductivity has to be tested in the laboratory of a third party accepted by PPA-Europe. The single test results have to be
7 Testing Rules for Thermal Conductivity (October 2015) 6 below the declared value. Furthermore, the results have to be added in the statistical evaluation to control that the newly calculated values of the thermal conductivity (λ Declared_new) and the design value (λ Design_new) are below or equal to the values of the initial type testing that are used for declaration on the CE-mark and for calculating the U-values (Uds). If the test results of the manufacturer and/or the accepted notified (test) laboratory show permanent deviation from the declared thermal conductivity, the declared and design values as well as the U-values (Uds) have to be adjusted in the Certification Document by an Independent Expert. Core material Mineral Wool PUR / PIR Others Type of production continuous continuous discontinuous discontinuous Single- / Meanλ-values Maximum deviation allowed (%) s 7,5 m 5 s 5 m 3 s 7,5 m 5 s 5 m 3 Table 1. Maximum deviation allowed between λ-values obtained by manufacturer and by the accepted notified (test) laboratory
Scheme rules for thermal insulation products for building equipment and industrial installations - VDI certification scheme
Scheme rules for thermal insulation products for building equipment and industrial installations - certification scheme April 6, 2011 1. Introduction This document presents the rules of the product certification
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
The University of Birmingham (Live System)
The University of Birmingham (Live System) Behaviour of Structural Insulated Panels (SIPs) under both short-term and long-term loadings Yang, Jian; Rungthonkit, Prathan Document Version Author final version
STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope
STEEL BUILDINGS IN EUROPE Single-Storey Steel Buildings Part 8: Building Envelope Single-Storey Steel Buildings Part 8: Building Envelope 2 - ii Part 8: Building Envelope emissions
Quality Regulations for Profiles
Quality Regulations for Profiles September 2010 Quality Regulations for Profiles Page 2/42 Contents Preface... 4 1. Terms and Definitions... 5 1.1 Third parties... 5 1.2 Independent laboratories... 5 1.3
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Prefabricated building PVC vertical sliding window
Prefabricated building PVC vertical sliding window SLOVENSKO ITALIA ESPAÑA ITALIA The company, we have the pleasure to introduce in this brochure, is an important and dynamic industrial company located
SANDWICH PANEL FILLING MATERIALS
SANDWICH PANEL FILLING MATERIALS Materials such as Polyurethane, PIR, Polystyrene, Phenolic Foam and Rockwool, etc. are the filling core materials mostly preferred in sandwich panel applications. All the
Master Panel 1000 R5 Roof
Master Panel 1000 R5 Roof Product Description The important feature of the roof elements are the easy installation procedure. The element fix exactly and pushed together without much force. Roof coverage
Linear thermal transmittance of the assembly of the glazing and the frame in windows
Linear thermal transmittance of the assembly of the glazing and the frame in windows Svend Svendsen,Professor, Technical University of Denmark; [email protected]; www.byg.dtu.dk Jacob B. Laustsen, Assistant
Master Panel 1000 W Wall
Master Panel 1000 W Wall Product Description In order to generate an aesthethic outlook wall panels are generally produced as micro hedge. Besides, in connection points concealed screw is used which provides
DECLARATION OF PERFORMANCE
Flooring Declaration of Performance Edition 01.07.2013 Identification no. Version no. 01 EN 1504-2: 2004 08 0921 EN 13813: 2002 DECLARATION OF PERFORMANCE Declaration of performance 1. Product Type Unique
ETAG 016 SELF-SUPPORTING COMPOSITE LIGHTWEIGHT PANELS. (Part one : G E N E R A L)
European Organisation for Technical Approvals Europäische Organisation für Technische Zulassungen Organisation Européenne pour l Agrément Technique Edition NOVEMBER 2003 GUIDELINE FOR EUROPEAN TECHNICAL
ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!
Secure and efficient IT room solutions Composite Panel Systems Compared Panel Systems are not all the same! When it comes to accommodating critical IT systems, the first issue to look at is the environment
03/05/14 REVISOR RSI/JC RD3945
1.1 Department of Commerce 1.2 Proposed Permanent Rules Relating to Commerce; Thermal Insulation Standards; 1.3 Materials and Installation 1.4 7640.0100 AUTHORITY; PURPOSE; INCORPORATIONS BY REFERENCE.
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Thermally Toughened Heat and Solar Control Glass 1 (C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics
Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver
Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver Designing an Effective Envelope Roofs Below Grade Walls and slabs Glazing & Windows Opaque portions of walls 2 3 Energy
Module 7. CE marking of Vehicle Restraint Systems EN 1317 5. Göran Fredriksson, SSBA
Module 7. CE marking of Vehicle Restraint Systems EN 1317 5 Göran Fredriksson, SSBA The Construction Products Regulation (CPR) is the basis The Construction Products Regulation (CPR) lays down harmonised
The Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors
23. december 2010 The Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors The Danish Enterprise and Construction Authority s market surveillance of construction
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems
CI/SfB (4-) Nh2 (A3j) May 2013 CI/SfB (4-) Nh2 (A3j) May 2013 Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems MINIMISING FIRE RISK Tata Steel have a long history of product
Module 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
Thermal Performance of Steel Beam Junctions using Different Connection Methods
Modern methods of construction and prefabrication Sustainable building design Construction and life cycle costing Steel, concrete, timber, masonry and glass construction Construction design guidance and
Your essential guide to CE Marking
Your essential guide to CE Marking CE marking A guide for window and door fabricators This guide provides essential information that will help you with your preparations for CE marking. A flowchart is
European Organisation for Technical Approvals
Warrington Certification Limited, Holmesfield Road, Warrington, WA1 2DS Tel. +44 (0) 1925-646777 Fax +44 (0) 1925-646667 Member of EOTA Authorised and notified according to Article 10 of the Council Directive
Check-list for auditors. Audit visit at candidate registered laboratories
Check-list for auditors Audit visit at candidate registered laboratories 1 Contents Introduction Laboratory documentation required by the standard(s), available for inspection by the auditor Items to be
Energy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
Test Report No. C908LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Changzhou He Jia Solar Energy
Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
Garage Sectional Doors
Garage Sectional Doors FROM TECKENTRUP TOP CLASS QUALITY DOORS MADE OF STEEL; ALUMINIUM OR WOOD W E O P E N T H E D O O R S F O R P R O G R E S S ECONOMICAL AND SPACE-SAVING FOR EVERY STRUCTURAL SITUATION
HFM Heat Flow Meter Thermal Conductivity Analyzer
HFM Heat Flow Meter Thermal Conductivity Analyzer Introduction An insulating material is a material with low thermal conductivity, which in the construction industry, equipment manufacturing, or the production
Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
BuildDesk U 3.4. Manual
BuildDesk U 3.4 Manual June 2010 Page 1 /102 Contents 1 Foreword...4 1.1 BuildDesk U 3.4...4 1.2 Help functions...4 1.2.1 Quickstart in 8 steps...4 1.2.2 BuildDesk Helpdesk...5 2 Introduction...6 2.1 Short
GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.
GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part
FIREPROOF Panels Trimoterm
FIREPROOF Panels Trimoterm FIREPROOF Panels Trimoterm Fireproof panels Trimoterm FTV and SNV are particularly convenient for constructing, where very high demands of fire resistance, sound reduction and
ProRox Slabs (formerly known as RW slabs)
Slabs (formerly known as RW slabs) Versatile thermal acoustic insulation slabs ROCKWOOL's Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are
FIRE BEHAVIOR CERTIFICATION OF THERMAL INSULATION MATERIALS
LNE Products FIRE/PS Review No. 3 - March 2015 FIRE BEHAVIOR CERTIFICATION OF THERMAL INSULATION MATERIALS RAW MATERIALS USED FOR THE MANUFACTURING OF EXPANDED POLYSTYRENE (EPS) EXTRUDED POLYSTYRENE FOAM
PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick
1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware
Annex to Accreditation Certificate D ZE 11349 01 00 according to DIN EN ISO/IEC 17065:2013
Deutsche Akkreditierungsstelle GmbH Annex to Accreditation Certificate D ZE 349 0 00 according to DIN EN ISO/IEC 7065:203 Period of validity: 30.06.205 to 09.05.209 Date of issue:: 30.06.205 Holder of
Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel
Hoesch Matrix System individuell ThyssenKrupp Steel Europe Thinking the future of steel 2 3 Steel in perfect shape and precision Steel the material of contemporary architecture. Throughout the production
Test Report No. C926LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: AMK-Collectra AG Bahnweg Nord
Loss Prevention Standard
Loss Prevention Standard LPS 1181: PART 1: ISSUE 1.1 Series of Fire Growth Tests for LPCB Approval and Listing of Construction Product Systems Part One: Requirements and Tests for Built-up Cladding and
FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS
INFORMATION PAPER IP 21/10 FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS Tom Lennon and Danny Hopkin The use of Structural Insulated Panel (SIP) systems in construction in the UK has increased
Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
HEADQUARTERS Purinova Sp. z o.o. ul. Wojska Polskiego 65 85-825 Bydgoszcz, Poland phone +48 523614710 fax +48 523614711 email [email protected] SALES DEPARTMENT phone +48 52 36 14 727, Marcin 722 150
Improving thermal insulation of concrete sandwich panel buildings
Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general
Dubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
High performance thermal insulation materials
thermal insulation materials Reducing energy use in buildings Civil and Environmental Engineering Building Technology Different materials Thermal conductivity (mw/mk) 45 40 35 30 25 20 15 10 5 0 Aerogel
European Technical Approval ETA 13/0282
European Technical Approval ETA 13/0282 Trade Name WILLCO Isolatiesysteem 2+4 Holder of the approval Website Generic type and use of construction product WILLCO Products N.V. Kwalestraat 72 B-9320 Nieuwerkerken
) and air spaces (R a
5.3.3 Thermal Resistance (R-value) Common thermal properties of materials and air spaces are based on steady state tests, which measure the heat that passes from the warm side to the cool side of the test
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
Insulation R-Value Comparisons
Insulation R-Value Comparisons American Ingenuity s component panels for the 22 48 domes contains seven inch thick rigid Expanded Polystyrene (E.P.S.) insulation which has an R value of 28. American Ingenuity
European Technical Approval ETA 13/0384
European Technical Approval ETA 13/0384 Trade Name Holder of the approval Website Generic type and use of construction product Isobriq EU, Isobriq LE, Isobriq PA & Isobriq ZE Isobriq sa 49 Rue Slar 4801
HEAT TRANSFER ANALYSIS OF COLD STORAGE
HEAT TRANSFER ANALYSIS OF COLD STORAGE Upamanyu Bangale and Samir Deshmukh Department of Mechanical Engineering, SGBA University, Amravati, India ABSTRACT India is largest producer of fruit and vegetable
8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS
8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS MARICA DELLA BELLA and DIEGO CIAN Precompressi Centro Nord S.p.A., Italy SUMMARY: Secondary roofing elements, complementary to the
AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY
PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall
Signs of insulation problems In the winter. In the summer. conditioning system
about your house CE 19 While previous generations may have been content to live in drafty houses, most people now want comfortable warm houses. A healthy house today is well sealed, well insulated and
Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature
Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST Instruction: Check each test method for which you are requesting accreditation. An asterisk beside the NVLAP Test Method Code indicates that proficiency
FACADE DESIGN & EXECUTION
Slides are available for public use PROVIDED credit to authors/organisation (M. Berckmoes & P. Lomba / VK Architects & Engineers) is clearly indicated. FACADE DESIGN & EXECUTION I N F O S T E EL - P R
Structural Insulated Panels: Design and Application
Sponsor Structural Insulated Panel Association 1201 Pacific Avenue Suite 600 Tacoma, WA 98402 Phone: 253 858 7472 Structural Insulated Panels: Design and Application Provider: Structural Insulated Panel
ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS
GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS ~GSM SHELTER CONTAINERS ARE PROCUDED ACCORDING TO THE DEMANDED SIZE.~ (W x L x H) Page1 GENERAL FEAUTURES Environmental Conditions : Maximum outdoor temperature
ETAG 004 EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING
European Organisation for Technical Approvals Europäische Organisation für Technische Zulassungen Organisation Européenne pour l Agrément Technique Edition March 2000 Amendment June 2008 GUIDELINE FOR
Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)
1 Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS) Introduction The new harmonised system for the classification of reaction to fire in EU member states is using the SBI test
Test Report No. C1319LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Thermics S.r.l. Via dell'olmo
Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
WORKING DOCUMENT FOR SCC CONSULTATION CONSTRUCT09/874 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL
WORKING DOCUMENT FOR SCC CONSULTATION CONSTRUCT09/874 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL New Approach Industries, Tourism and CSR Construction, Pressure Equipment, Metrology
Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC. GNB-CPD position paper from SG17 - EN 1090-1:2009
GNB-CPD SG17 Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC NB-CPD/SG17/09/069 Issued: 7 September 2009 APPROVED GUIDANCE GNB-CPD position paper from SG17
Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
Building Envelope Design using ROXUL Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB
Rockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011
1. plan 1) Goal: Assessment and verification of the constancy of performance of the products as described by the manufacturer in his Declaration of Performance through: initial inspection of the manufacturing
B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.
Rigid, Semirigid and Flexible Slabs Versatile thermal acoustic insulation slabs ROCKWOOL are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are manufactured
REACTION TO FIRE CLASSIFICATION REPORT No. RA15-0088 ACCORDING TO THE EUROPEAN STANDARD NF EN 13501-1+A1:2013
SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT No. RA150088 ACCORDING TO THE EUROPEAN STANDARD 135011+A1:2013 Notification by the French Government to the
APIB Test Specification No. 09 WATERPROOFING MEMBRANES SWISS HAIL IMPACT PROTECTION REGISTER HSR. 01.07.2015 / 07-15en Version 1.
Association of Public Insurance Companies (APIB) Association des établissements cantonaux d assurance incendie SWISS HAIL IMPACT PROTECTION REGISTER HSR APIB Test Specification No. 09 WATERPROOFING MEMBRANES
General Properties of Polyurethane Insulation. Chris Ungermand Huntsman Nordic IDA Fyn seminar Odense 15-4 2015
General Properties of Polyurethane Insulation Chris Ungermand Huntsman Nordic IDA Fyn seminar Odense 15-4 2015 Drivers for insulation growth Mega trends Population (billion) 7.1 5.29 2.53 0.77 0.25 0.006-10
Glass partitions SFB 3074
Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use
DOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS
CONFORMITY ASSESSMENT FOR THE EXECUTION OF STEEL & ALUMINIUM STRUCTURES DOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS 2nd Edition July 2012 Issued under the authority of the Governing Board for Certification
STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
Mineral fibreglass insulation
Isover MULTIMAX 30 Specification code: MW - EN 13162 - T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering
European technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA 18000 / Israel. J. Magner Dipl.-Ing. N. Machill.
Kiwa Polymer Institut GmbH Quellenstraße 3 65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 7013-E Testing order: Test of the waterproofing system based
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics
Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals
UL INTERNATIONAL (UK) LTD Wonersh House, Building C, The Guildway, Old Portsmouth Road, Guildford. GU3 1LR. United Kingdom. Phone : +44 1483 302130 Fax : +44 1483 302230 Email : [email protected] Website
ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):
ENERGY AUDIT Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM): Leonard Fernandes DERBIGUM project reference : UAE -2014 - EA 103 Author : Daniel Heffinck (DERBIGUM)
Eurooppalainen tekninen hyväksyntä ETA - 13/0613 European Technical Approval
VTT Expert Services Ltd PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings
INSULATION FOR PRE-ENGINEERED METAL BUILDINGS ROXUL SAFE 55 & 65 and ROXUL PLUS MB Insulation for Pre-Engineered Metal Buildings ROXUL SAFE AND ROXUL PLUS MB Exterior Wall Insulation for Pre-Engineered
Part A: Fluid properties
UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material on HFC for management: HFC Workshop, technical 2015 issues Bangkok, 20 and 21 April 2015 FACT SHEET 15 Glossary of terms and technical
ETAG 022. GUIDELINE FOR EUROPEAN TECHNICAL APPROVAL of Watertight covering kits for wet room floors and or walls
European Organisation for Technical Approvals Europäische Organisation für Technische Zulassungen Organisation Européenne pour l Agrément Technique ETAG 022 GUIDELINE FOR EUROPEAN TECHNICAL APPROVAL of
European Technical Approval ETA 12/0419
FM Approvals Limited 1 Windsor Dials Windsor Berkshire SL4 1RS United Kingdom Tel.: +44 (0)1753 750000 Fax: +44 (0)1753 868700 E-mail: [email protected] Internet: www.fmapprovals.com Member of EOTA European
Long-Term Hygrothermal Performance of Green Roofs
Long-Term Hygrothermal Performance of Green Roofs D. Zirkelbach B. Schafaczek H. Künzel, PhD Member ASHRAE ABSTRACT Green roofs are becoming more and more popular because their thermal inertia, combined