CE Marking of Glass products
|
|
|
- Ellen Jenkins
- 10 years ago
- Views:
Transcription
1 CE Marking of Glass products INTRODUCTION ARTLITE ARTLITE / ARTLITE DIGITAL HEAT STRENGTHENED ARTLITE / ARTLITE DIGITAL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 1 ARTLITE / ARTLITE DIGITAL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED BLACKPEARL BLACKPEARL (ANNEALED) BLACKPEARL HEAT STRENGTHENED BLACKPEARL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED COLORBEL COLORBEL HEAT STRENGTHENED COLORBEL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED COLORBEL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED CONCEPTA... 2 CONCEPTA GH PHON GH PHON GH PHON GH PHON IMAGIN IMAGIN CLEAR (ANNEALED)... 0 IMAGIN CLEAR (ANNEALED)... 1 IMAGIN CLEAR HEAT STRENGTHENED... 2 IMAGIN CLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... IMAGIN CLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 4 IMAGIN EXTRA CLEAR (ANNEALED)... 5 IMAGIN EXTRA CLEAR HEAT STRENGTHENED... 6 IMAGIN EXTRA CLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 7 IMAGIN BRONZE (ANNEALED)... 8 IMAGIN BRONZE HEAT STRENGTHENED... 9 IMAGIN BRONZE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IMAGIN YELLOW (ANNEALED) IMAGIN YELLOW HEAT STRENGTHENED IMAGIN YELLOW THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 4 IMAGIN WIRED IMAGIN WIRED CLEAR (ANNEALED) IMAGIN WIRED O AND WIRED S (ANNEALED) IMAGIN WIRED BRONZE (ANNEALED) IMAGIN WIRED YELLOW (ANNEALED) IPACLEAR IPACLEAR (ANNEALED) IPACLEAR HEAT STRENGTHENED IPACLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPASOL
2 IPASOL BRIGHT NEUTRAL (ANNEALED) IPASOL BRIGHT WHITE (ANNEALED) IPASOL NEUTRAL 50/27 (ANNEALED) IPASOL NEUTRAL 60/ (ANNEALED) IPASOL NEUTRAL 69/7 (ANNEALED) IPASOL NEUTRAL 70/9 (ANNEALED) IPASOL NEUTRAL 7/42 (ANNEALED) IPASOL PLATIN 25/17 (ANNEALED) IPASOL PLATIN 47/29 (ANNEALED) IPASOL SHINE 40/22 (ANNEALED)... 6 IPASOL SKY 0/17 (ANNEALED) IPASOL ULTRASELECT 62/29 (ANNEALED) IPAWHITE IPAWHITE (ANNEALED) IPAWHITE HEAT STRENGTHENED IPAWHITE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPLUS IPLUS ADVANCED 1.0 (ANNEALED) IPLUS ADVANCED 1.0 ON CLEARVISION (ANNEALED) IPLUS AF (ANNEALED)... 7 IPLUS AF HEAT STRENGTHENED IPLUS AF THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPLUS AF ENERGY N (ANNEALED) IPLUS AF TOP (ANNEALED) IPLUS ENERGY N (ANNEALED) IPLUS ENERGY N ON CLEARVISION (ANNEALED) IPLUS ENERGY NT (ANNEALED) IPLUS ENERGY NT HEAT STRENGTHENED IPLUS ENERGY NT THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPLUS I-TOP (ANNEALED)... 8 IPLUS I-TOP ON CLEARVISION (ANNEALED) IPLUS LIGHT (ANNEALED) IPLUS LS (ANNEALED) IPLUS LST (ANNEALED) IPLUS LST HEAT STRENGTHENED IPLUS LST THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPLUS TOP 1.0 (ANNEALED) IPLUS TOP 1.1 (ANNEALED) IPLUS TOP 1.1 ON CLEARVISION (ANNEALED) IPLUS TOP 1.1T (ANNEALED)... 9 IPLUS TOP 1.1T HEAT STRENGTHENED IPLUS TOP 1.1T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPLUS TOP 1.1T ON CLEARVISION (ANNEALED) IPLUS TOP 1.1T ON CLEARVISION HEAT STRENGTHENED IPLUS TOP 1.1T ON CLEARVISION THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPLUS TWIN TOP (ANNEALED) IPLUS 1.0 (ANNEALED) IPLUS ALPHA N (ANNEALED) IPLUS ALPHA N HEAT STRENGTHENED IPLUS ALPHA N THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPLUS E (ANNEALED) IPLUS ET (ANNEALED) IPLUS ET HEAT STRENGTHENED IPLUS ET THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED IPLUS TWIN E (ANNEALED) LACOBEL T LACOBEL T HEAT STRENGTHENED LACOBEL T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED MIROX G
3 MIROX G CLEAR MIROX G CLEARVISION MIROX G BLACK MIROX MIROX G BRONZE MIROX G GREEN MIROX G GREY MIROX G PRIVABLUE MIROX MNGE MIROX MNGE CLEAR MIROX MNGE CLEARVISION MIROX MNGE BLACK MIROX MIROX MNGE BRONZE MIROX MNGE GREEN MIROX MNGE GREY MIROX MNGE PRIVABLUE PLANIBEL CLEAR PLANIBEL CLEAR (ANNEALED) PLANIBEL CLEAR (ANNEALED) PLANIBEL CLEAR HEAT STRENGTHENED PLANIBEL CLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL LINEA AZZURRA (ANNEALED)... 1 PLANIBEL LINEA AZZURRA HEAT STRENGTHENED PLANIBEL LINEA AZZURRA THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL CLEARVISION, SUNMAX, SUNMAX PREMIUM (ANNEALED) PLANIBEL CLEARVISION, SUNMAX, SUNMAX PREMIUM (ANNEALED) PLANIBEL CLEARVISION, SUNMAX, SUNMAX PREMIUM HEAT STRENGTHENED PLANIBEL CLEARVISION, SUNMAX, SUNMAX PREMIUM THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL CLEARVISION, SUNMAX, SUNMAX PREMIUM THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL CLEAR PLUS (ANNEALED) PLANIBEL COLOURED PLANIBEL AZUR (ANNEALED) PLANIBEL AZUR HEAT STRENGTHENED PLANIBEL AZUR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL BRONZE (ANNEALED) PLANIBEL BRONZE HEAT STRENGTHENED PLANIBEL BRONZE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL DARK BLUE (ANNEALED) PLANIBEL DARK BLUE HEAT STRENGTHENED PLANIBEL DARK BLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL DARK GREY (ANNEALED) PLANIBEL DARK GREY HEAT STRENGTHENED PLANIBEL DARK GREY THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL GREEN (ANNEALED) PLANIBEL GREEN HEAT STRENGTHENED PLANIBEL GREEN THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL GREY (ANNEALED) PLANIBEL GREY HEAT STRENGTHENED PLANIBEL GREY THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL PRIVABLUE (ANNEALED) PLANIBEL PRIVABLUE HEAT STRENGTHENED PLANIBEL PRIVABLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL LOW-E PLANIBEL A (ANNEALED) PLANIBEL A HEAT STRENGTHENED PLANIBEL A THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL G (ANNEALED) PLANIBEL G HEAT STRENGTHENED
4 PLANIBEL G THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL G FAST (ANNEALED) PLANIBEL G FAST HEAT STRENGTHENED PLANIBEL G FAST THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL HORTIPLUS N (ANNEALED) PLANIBEL HORTIPLUS N HEAT STRENGTHENED PLANIBEL HORTIPLUS N THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED AF IPLUS E (ANNEALED) PLANIBEL AF TOP N+ (ANNEALED) PLANIBEL TOP N (ANNEALED) PLANIBEL TOP N+ (ANNEALED) PLANIBEL TOP NT HEAT STRENGTHENED PLANIBEL TOP NT THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL TOP N+T (ANNEALED) PLANIBEL TOP N+T HEAT STRENGTHENED PLANIBEL TOP N+T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED PLANIBEL TRI (ANNEALED) PLANIBEL TRI ON CLEARVISION (ANNEALED) POLISHED WIRED GLASS POLISHED WIRED GLASS PYROBELITE / PYROBEL PYROBELITE PYROBELITE PYROBELITE PYROBEL PYROBEL PYROBEL PYROBEL PYROBEL PYROBEL PYROBEL PYROBEL PYROBEL PYROPANE PYROPANE 100 PYROPANE PYROPANE 100 SB PYROPANE ; /100 ; ; 201 ; 201/100 ; PYROPANE PYROPANE PYROPANE PYROPANE PYROPANE SOLAR PATTERNED GLASS ASTRALITE (ANNEALED) ASTRALITE THERMALLY TOUGHENED SOLATEX (ANNEALED) SOLATEX THERMALLY TOUGHENED SOLITE (ANNEALED) SOLITE THERMALLY TOUGHENED STOPRAY STOPRAY INDIGO 48T (ANNEALED) STOPRAY INDIGO 48T HEAT STRENGTHENED STOPRAY INDIGO 48T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY LIME 61T (ANNEALED) STOPRAY LIME 61T HEAT STRENGTHENED STOPRAY LIME 61T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY SILVER (ANNEALED) STOPRAY SILVER HEAT STRENGTHENED STOPRAY SILVER THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED
5 STOPRAY SILVER ON CLEARVISION (ANNEALED) STOPRAY SILVER ON CLEARVISION HEAT STRENGTHENED STOPRAY SILVER ON CLEARVISION THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY SMART 0/20 (ANNEALED) STOPRAY SMART 0/20 HEAT STRENGTHENED STOPRAY SMART 0/20 THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 2 STOPRAY SMART 51/ (ANNEALED) STOPRAY SMART 51/ HEAT STRENGTHENED STOPRAY SMART 51/ THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY TITANIUM 7T (ANNEALED) STOPRAY TITANIUM 7T HEAT STRENGTHENED STOPRAY TITANIUM 7T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY VISION-6T (ANNEALED) STOPRAY VISION-6T HEAT STRENGTHENED STOPRAY VISION-6T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY VISION-50 (ANNEALED) STOPRAY VISION-50 ON CLEARVISION (ANNEALED) STOPRAY VISION-50T (ANNEALED) STOPRAY VISION-50T HEAT STRENGTHENED STOPRAY VISION-50T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY VISION-60 (ANNEALED) STOPRAY VISION-60T (ANNEALED) STOPRAY VISION-60T HEAT STRENGTHENED STOPRAY VISION-60T THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY ULTRA-50 ON CLEARVISION (ANNEALED) STOPRAY ULTRA-60 (ANNEALED) STOPRAY AQUAMARINE (ANNEALED) STOPRAY AQUAMARINE HEAT STRENGTHENED STOPRAY AQUAMARINE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY BLUE NIGHT (ANNEALED) STOPRAY BLUE NIGHT HEAT STRENGTHENED STOPRAY BLUE NIGHT THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY BRIGHT SEPIA (ANNEALED) STOPRAY BRIGHT SEPIA HEAT STRENGTHENED STOPRAY BRIGHT SEPIA THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY CARAT (ANNEALED) STOPRAY CARAT HEAT STRENGTHENED STOPRAY CARAT THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY CHROMA (ANNEALED) STOPRAY CHROMA HEAT STRENGTHENED STOPRAY CHROMA THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY CRISTAL (ANNEALED) STOPRAY CRISTAL HEAT STRENGTHENED STOPRAY CRISTAL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY DEEP BLUE (ANNEALED) STOPRAY DEEP BLUE HEAT STRENGTHENED STOPRAY DEEP BLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY ELITE (ANNEALED) STOPRAY ELITE HEAT STRENGTHENED STOPRAY ELITE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY ELITE ON CLEARVISION (ANNEALED) STOPRAY ELITE ON CLEARVISION HEAT STRENGTHENED STOPRAY ELITE ON CLEARVISION THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY EMERALDA (ANNEALED) STOPRAY EMERALDA HEAT STRENGTHENED STOPRAY EMERALDA THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY GALAXY (ANNEALED) STOPRAY GALAXY HEAT STRENGTHENED STOPRAY GALAXY THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY GALAXY ON CLEARVISION (ANNEALED) STOPRAY GALAXY ON CLEARVISION HEAT STRENGTHENED STOPRAY GALAXY ON CLEARVISION THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY GRANIT GREY (ANNEALED)
6 STOPRAY GRANIT GREY HEAT STRENGTHENED STOPRAY GRANIT GREY THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY MARINE BLUE (ANNEALED) STOPRAY MARINE BLUE HEAT STRENGTHENED STOPRAY MARINE BLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY METAL BLUE (ANNEALED) STOPRAY METAL BLUE HEAT STRENGTHENED STOPRAY METAL BLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY NEUTRAL (ANNEALED) STOPRAY NEUTRAL HEAT STRENGTHENED STOPRAY NEUTRAL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY OASIS (ANNEALED) STOPRAY OASIS HEAT STRENGTHENED... 0 STOPRAY OASIS THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY QUARTZ (ANNEALED) STOPRAY QUARTZ HEAT STRENGTHENED STOPRAY QUARTZ THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY REFLEX BLUE (ANNEALED) STOPRAY REFLEX BLUE HEAT STRENGTHENED STOPRAY REFLEX BLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY SAFIR (ANNEALED) STOPRAY SAFIR HEAT STRENGTHENED STOPRAY SAFIR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 1 STOPRAY SAFIR ON CLEARVISION (ANNEALED) STOPRAY SAFIR ON CLEARVISION HEAT STRENGTHENED STOPRAY SAFIR ON CLEARVISION THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY SELVA (ANNEALED) STOPRAY SELVA HEAT STRENGTHENED STOPRAY SELVA THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY SIENNA (ANNEALED) STOPRAY SIENNA HEAT STRENGTHENED STOPRAY SIENNA THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY TOPAZ (ANNEALED)... 2 STOPRAY TOPAZ HEAT STRENGTHENED STOPRAY TOPAZ THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPRAY ULTRAMARINE (ANNEALED) STOPRAY ULTRAMARINE HEAT STRENGTHENED STOPRAY ULTRAMARINE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL STOPSOL CLASSIC CLEAR (ANNEALED)... 0 STOPSOL CLASSIC CLEAR HEAT STRENGTHENED... 1 STOPSOL CLASSIC CLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 2 STOPSOL CLASSIC BRONZE (ANNEALED)... STOPSOL CLASSIC BRONZE HEAT STRENGTHENED... 4 STOPSOL CLASSIC BRONZE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 5 STOPSOL CLASSIC DARK BLUE (ANNEALED)... 6 STOPSOL CLASSIC DARK BLUE HEAT STRENGTHENED... 7 STOPSOL CLASSIC DARK BLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 8 STOPSOL CLASSIC GREEN (ANNEALED)... 9 STOPSOL CLASSIC GREEN HEAT STRENGTHENED STOPSOL CLASSIC GREEN THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL CLASSIC GREY (ANNEALED) STOPSOL CLASSIC GREY HEAT STRENGTHENED... 4 STOPSOL CLASSIC GREY THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL PHOENIX CLEAR (ANNEALED) STOPSOL PHOENIX CLEAR HEAT STRENGTHENED STOPSOL PHOENIX CLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL PHOENIX GREEN (ANNEALED) STOPSOL PHOENIX GREEN HEAT STRENGTHENED STOPSOL PHOENIX GREEN THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL PHOENIX GREY (ANNEALED) STOPSOL PHOENIX GREY HEAT STRENGTHENED
7 STOPSOL PHOENIX GREY THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 5 STOPSOL SILVERLIGHT PRIVABLUE (ANNEALED) STOPSOL SILVERLIGHT PRIVABLUE HEAT STRENGTHENED STOPSOL SILVERLIGHT PRIVABLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL SUPERSILVER CLEAR (ANNEALED) STOPSOL SUPERSILVER CLEAR HEAT STRENGTHENED STOPSOL SUPERSILVER CLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL SUPERSILVER DARK BLUE (ANNEALED) STOPSOL SUPERSILVER DARK BLUE HEAT STRENGTHENED STOPSOL SUPERSILVER DARK BLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL SUPERSILVER GREEN (ANNEALED)... 6 STOPSOL SUPERSILVER GREEN HEAT STRENGTHENED STOPSOL SUPERSILVER GREEN THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STOPSOL SUPERSILVER GREY (ANNEALED) STOPSOL SUPERSILVER GREY HEAT STRENGTHENED STOPSOL SUPERSILVER GREY THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED STRATOBEL STRATOBEL CLEAR (22.X,.X) STRATOBEL CLEAR (44.X, 55.X) STRATOBEL CLEAR (66.X) STRATOBEL CLEAR (88.X, X)... 7 STRATOBEL LINEA AZZURRA (88.X, X) STRATOBEL IPLUS ENERGY N STRATOBEL IPLUS G STRATOBEL IPLUS I-TOP STRATOBEL IPLUS I-TOP STRATOBEL IPLUS LIGHT STRATOBEL IPLUS TOP STRATOBEL IPLUS TOP STRATOBEL LOW-E TOP N STRATOBEL LOW-E TOP N STRATOBEL LOW-E TOP N STRATOBEL LOW-E TRI STRATOBEL LOW-E TRI STRATOBEL STOPRAY LAMISMART STRATOBEL STOPRAY LAMISMART 24 (LAMINATED WITH PLANIBEL BRONZE) STRATOBEL STOPRAY LAMISMART 24 (LAMINATED WITH PLANIBEL DARK BLUE) STRATOBEL STOPRAY LAMISMART 24 (LAMINATED WITH PLANIBEL GREEN) STRATOBEL STOPRAY LAMISMART 24 (LAMINATED WITH PLANIBEL GREY) STRATOBEL (BURGLAR RESISTANT) STRATOBEL (BULLET RESISTANT)... 9 STRATOBEL (BULLET RESISTANT) STRATOBEL (BULLET RESISTANT) STRATOBEL (BULLET RESISTANT) STRATOBEL (BULLET RESISTANT) STRATOBEL (BULLET RESISTANT) STRATOBEL (BULLET RESISTANT) STRATOBEL (BULLET RESISTANT) IN DGU STRATOBEL (BULLET RESISTANT) IN DGU STRATOBEL (BULLET RESISTANT) IN DGU STRATOBEL (BLAST RESISTANT) STRATOBEL COLOR STANDARD STRATOBEL COLOR STANDARD STRATOBEL COLOR RAINNBOW STRATOBEL COLOR RAINBOW STRATOBEL COLOR RAINBOW STRATOBEL EVA STRATOBEL EVA STRATOBEL IMPRESSION STRATOBEL IMPRESSION
8 STRATOBEL PC STRATOBEL PC (BURGLAR RESISTANT) STRATOBEL PC (BULLET RESISTANT) STRATOBEL PC (BULLET RESISTANT) STRATOBEL PC (BULLET RESISTANT) IN DGU STRATOBEL OTHER PRODUCTS STRATOBEL OTHER PRODUCTS (LEVEL ) STRATOBEL OTHER PRODUCTS (LEVEL 1) STRATOBEL OTHER PRODUCTS (LEVEL ) STRATOBEL OTHER PRODUCTS (LEVEL 1) STRATOPHONE STRATOPHONE CLEAR (22.X,.X) STRATOPHONE CLEAR (44.X) STRATOPHONE CLEAR (55.X, 66.X, 88.X) STRATOPHONE IPLUS ENERGY N STRATOPHONE IPLUS I-TOP STRATOPHONE IPLUS LIGHT STRATOPHONE IPLUS TOP STRATOPHONE IPLUS TOP STRATOPHONE LOW-E TOP N STRATOPHONE LOW-E TOP N STRATOPHONE LOW-E TRI SUNERGY SUNERGY CLEAR (ANNEALED) SUNERGY CLEAR HEAT STRENGTHENED SUNERGY CLEAR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED SUNERGY AZUR (ANNEALED) SUNERGY AZUR HEAT STRENGTHENED SUNERGY AZUR THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED SUNERGY DARK BLUE (ANNEALED) SUNERGY DARK BLUE HEAT STRENGTHENED SUNERGY DARK BLUE THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED SUNERGY GREEN (ANNEALED) SUNERGY GREEN HEAT STRENGTHENED SUNERGY GREEN THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED SUNERGY GREY (ANNEALED) SUNERGY GREY HEAT STRENGTHENED SUNERGY GREY THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED SUNEWAT SUNEWAT L 44.4 HEAT STENGTHENED SUNEWAT L 44.4 THERMALLY TOUGHENED SUNEWAT XL 55.6 THERMALLY TOUGHENED SUNEWAT XL 66.6 THERMALLY TOUGHENED SUNEWAT XL 88.6 THERMALLY TOUGHENED SUNEWAT XL THERMALLY TOUGHENED THERMALLY TOUGHENED GLASS FOR SHOWER ENCLOSURE THERMOBEL THERMOBEL (LEVEL PRODUCTS) THERMOBEL (LEVEL 1 PRODUCTS) THERMOBEL VIP THERMOBEL VIP THERMOBEL VIP THERMOBEL VIP THERMOBEL VIP TRANSLATIONS
9 ENGLISH BULGARIAN (БЪЛГАРСКИ) ENGLISH ČEŠTINA ENGLISH DANSK ENGLISH DEUTSCH ENGLISH EESTI KEEL ENGLISH ελληνικα ENGLISH ESPAÑOL ENGLISH FRANÇAIS ENGLISH ITALIANO ENGLISH LATVIEŠU VALODA ENGLISH LIETUVIU KALBA ENGLISH MAGYAR ENGLISH NEDERLANDS ENGLISH NORKS ENGLISH POLSKI ENGLISH ROMANIAN ENGLISH PORTUGUÊS ENGLISH SLOVENČINA ENGLISH SLOVENŠČINA ENGLISH SUOMI ENGLISH SVENSKA
10 Introduction This file gives CE declarations and performances for basis glass products of AGC Glass Europe : Float Patterned glass Wired glas Polished wired glass Coatings Heat treated glass For laminated glass and insulating glass unit, some glass compositions are indicated but it is not possible to list all glass structures. The CE declarations and performances of these products are available on in one of the dynamic tools of My Glass Toolbox: Advanced product finder Glass Configurator General informations concerning CE-Marking and links to these tools are available at Remark Some products listed in this file are out of range, not standard in catalogue and/or only dedicated to a specific market. For the availability, please consult 10
11 Artlite 11
12 CE Marking of Heat strengthened glass - EN 186-2:2004 Artlite / Artlite Digital Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Artlite / Artlite Digital Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Artlite/Artlite Digital Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 12
13 CE Marking of Thermally toughened glass - EN :2004:2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Artlite / Artlite Digital Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Artlite/Artlite Digital Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004:2004 / EN :2005 NB Artlite/Artlite Digital Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 1
14 CE Marking of Thermally toughened glass - EN :2004:2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Artlite / Artlite Digital Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Artlite/Artlite Digital Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004:2004 / EN :2005 NB Artlite/Artlite Digital Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 12 mm 15 mm 19 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 5 (-2;-) NPD NPD U-value (EN 67) NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 14
15 Blackpearl 15
16 CE Marking of Coated glass - EN :2004 Blackpearl (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Blackpearl, intended to be used in buildings and construction works, following EN :2004 NB Blackpearl characteristics in : AVCP Systems 8 mm 1. Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 A1. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-2) U-value (EN 67) 5,7 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 2/2/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2/26/ Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 16
17 CE Marking of Heat strengthened glass - EN 186-2:2004 Blackpearl Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Blackpearl Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Blackpearl Heat strengthened characteristics in : AVCP Systems 8 mm 1. Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 A1. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) NPD 8. Resistance against sudden temperature change and temperature differentials K 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-2) U-value (EN 67) 5,7 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 2/2/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2/26/ Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 17
18 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Blackpearl Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Blackpearl Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / EN :2005 NB Blackpearl Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 8 mm 1. Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 A1. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) 1C2 8. Resistance against sudden temperature change and temperature differentials K 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-2) U-value (EN 67) 5,7 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 2/2/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2/26/ Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 18
19 Colorbel 19
20 CE Marking of Heat strengthened glass - EN 186-2:2004 Colorbel Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Colorbel Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Colorbel Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 20
21 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Colorbel Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Colorbel Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Colorbel Thermally toughened or Heat soaked thermally toughened AVCP characteristics in : Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 21
22 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Colorbel Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Colorbel Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Colorbel Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 12 mm 15 mm 19 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 5 (-2;-) NPD NPD U-value (EN 67) NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 22
23 Concepta 2
24 CE Marking of Laminated glass EN 14449: AC:2005 Concepta Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Concepta, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Concepta characteristics: AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 24
25 GH Phon 25
26 CE Marking of Laminated glass EN 14449: AC:2005 GH Phon Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named GH Phon, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB GH Phon characteristics in : AVCP Systems , , , Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD 7 (-1;-2) NPD NPD NPD NPD U-value (EN 67) 5,5 5,5 5,5 5,5 5,5 5,4 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 8 / 8 88 / 8 / 8 87 / 8 / 8 87 / 8 / 8 87 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 76 / 7 / 7 75 / 7 / 7 74 / 7 / 7 74 / 7 / 7 7 / 7 / 7 72 / 7 / 7 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 26
27 CE Marking of Laminated glass EN 14449: AC:2005 GH Phon Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named GH Phon, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB GH Phon characteristics in : AVCP Systems , , , Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD 8 (0;-2) NPD 8 (0;-) NPD NPD U-value (EN 67) 5,5 5,4 5,4 5,4 5,4 5, 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 8 / 8 87 / 8 / 8 86 / 8 / 8 86 / 8 / 8 85 / 8 / 8 85 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 7 / 7 72 / 7 / 7 70 / 7 / 7 69 / 7 / 7 68 / 7 / 7 67 / 6 / 6 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 27
28 CE Marking of Laminated glass EN 14449: AC:2005 GH Phon Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named GH Phon, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB GH Phon characteristics in : AVCP Systems , , , Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD U-value (EN 67) 5, 5,2 5,2 5,2 5,2 5,2 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 8 / 8 84 / 8 / 8 8 / 8 / 8 8 / 8 / 8 82 / 7 / 7 82 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 65 / 6 / 6 65 / 6 / 6 6 / 6 / 6 6 / 6 / 6 61 / 6 / 6 60 / 6 / 6 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 28
29 Imagin 29
30 CE Marking of Patterned glass - EN 572-9:2004 Imagin clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Clear, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin clear characteristics in : AVCP Systems 2 mm mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 88 / 8 / 8 86 / 8 / 8 84 / 8 / 8 82 / 7 / 7 80 / 7 / 7 77 / 7 / Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 0
31 CE Marking of Patterned glass - EN 572-9:2004 Imagin clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Clear, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin clear characteristics in : AVCP Systems 10 mm 1,5 mm 15 mm 19mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-2;-) NPD NPD NPD U-value (EN 67) 5,6 5,5 5,5 5,4 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 8 / 8 85 / 8 / 8 84 / 8 / 8 82 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 74 / 7 / 7 70 / 7 / 7 67 / 6 / 6 6 / 6 / 6 79 NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 1
32 CE Marking of Heat strengthened glass - EN 186-2:2004 Imagin clear Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Clear Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Imagin clear Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 87 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 84 / 8 / 8 82 / 7 / 7 80 / 7 / 7 77 / 7 / 7 74 / 7 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 2
33 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Imagin clear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Clear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Imagin clear Thermally toughened or Heat soaked thermally toughened AVCP 4 mm 5 mm 6 mm 8 mm 10 mm characteristics in : Systems 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 87 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 84 / 8 / 8 82 / 7 / 7 80 / 7 / 7 77 / 7 / 7 74 / 7 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building
34 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Imagin clear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Clear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Imagin clear Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 1,5 mm 15 mm 19mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 5,5 5,5 5,4 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 85 / 8 / 8 84 / 8 / 8 82 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 7 / 7 67 / 6 / 6 6 / 6 / 6 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 4
35 CE Marking of Patterned glass EN 572-9:2004 Imagin extra clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Extra Clear, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin extra clear characteristics in : AVCP Systems 2 mm mm 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92/8/8 92/8/8 92/8/8 91/8/8 91/8/8 91/8/8 91/8/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91/8/8 91/8/8 91/8/8 91/8/8 90/8/8 90/8/8 90/8/8 NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 5
36 CE Marking of Heat strengthened glass - EN 186-2:2004 Imagin extra clear Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Extra Clear Heat strengthened, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin extra clear Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92/8/8 91/8/8 91/8/8 91/8/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91/8/8 91/8/8 90/8/8 90/8/8 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 6
37 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Imagin extra clear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Extra Clear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Imagin extra clear Thermally toughened or Heat soaked thermally AVCP toughened characteristics in : Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92/8/8 91/8/8 91/8/8 91/8/8 91/8/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91/8/8 91/8/8 90/8/8 90/8/8 90/8/8 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 7
38 CE Marking of Wired patterned glass - EN 572-9:2004 Imagin bronze (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Bronze, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin bronze characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 59 / 6 / 6 52 / 6 / 6 46 / 5 / 5 7 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 60 / 6 / 6 54 / 6 / 6 49 / 5 / 5 40 / 5 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 8
39 CE Marking of Heat strengthened glass - EN 186-2:2004 Imagin bronze Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Bronze Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Imagin bronze Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 59 / 6 / 6 52 / 6 / 6 46 / 5 / 5 7 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 60 / 6 / 6 54 / 6 / 6 49 / 5 / 5 40 / 5 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 9
40 CE Marking of Thermally toughened - EN :2004 CE Marking of Heat soaked Thermally toughened or - EN :2005 Imagin bronze Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Bronze Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Imagin bronze Thermally toughened or Heat soaked thermally AVCP toughened characteristics in : Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 59 / 6 / 6 52 / 6 / 6 46 / 5 / 5 7 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 60 / 6 / 6 54 / 6 / 6 49 / 5 / 5 40 / 5 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 40
41 CE Marking of Wired patterned glass - EN 572-9:2004 Imagin yellow (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Yellow, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin yellow characteristics in : AVCP Systems 4 mm 5 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 7 / 7 / 7 69 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 61 / 6 / 6 55 / 6 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 41
42 CE Marking of Heat strengthened glass - EN 186-2:2004 Imagin yellow Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Yellow Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Imagin yellow Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 7 / 7 / 7 69 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 61 / 6 / 6 55 / 6 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 42
43 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Imagin yellow Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Yellow Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Imagin yellow Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 7 / 7 / 7 69 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 61 / 6 / 6 55 / 6 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 4
44 Imagin wired 44
45 CE Marking of Wired patterned glass - EN 572-9:2004 Imagin wired clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Wired Clear, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin wired clear characteristics in : AVCP Systems 6 mm 7 mm 9 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 5,7 5,7 5,6 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 8 / 8 88 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 80 / 7 / 7 79 / 7 / 7 76 / 7 / 7 8 NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 45
46 CE Marking of Wired patterned glass - EN 572-9:2004 Imagin wired O and wired S (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Wired O and Wired S, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin wired clear characteristics in : AVCP Systems Wired O 6 mm Wired S 6 mm Wired S 7 mm 1. Resistance to fire (EN ) 1 E45 E 0 E 0 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 5,7 5,7 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 8 / 8 89 / 8 / 8 88 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 80 / 7 / 7 80 / 7 / 7 79 / 7 / NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 46
47 CE Marking of Wired patterned glass - EN 572-9:2004 Imagin wired bronze (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Wired Bronze, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin wired bronze characteristics in : AVCP Systems 6 mm 1. Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 A1. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD U-value (EN 67) 5,7 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 46 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 49 / 5 / Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 47
48 CE Marking of Wired patterned glass - EN 572-9:2004 Imagin wired yellow (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Imagin Wired Yellow, intended to be used in buildings and construction works, following EN 572-9:2004 NB Imagin wired yellow characteristics in : AVCP Systems 6 mm 1. Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 A1. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD U-value (EN 67) 5,7 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 65 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 51 / 6 / Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 48
49 ipaclear 49
50 CE Marking of Float glass - EN 572-9:2004 ipaclear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipaclear, intended to be used in buildings and construction works, following EN 572-9:2004 NB ipaclear characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 5,6 5,5 NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 91 / 8 / 8 90 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 88 / 8 / 8 87 / 8 / 8 86 / 8 / 8 86 / 8 / 8 84 / 8 / 8 82 / 8 / 8 81 / 8 / 8 NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS 2rd of June Primary Sales & Strategic, Marketing Director, Building 50
51 CE Marking of Heat strengthened glass - EN 186-2:2004 ipaclear Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipaclear Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB ipaclear Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 5,6 NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 90 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 87 / 8 / 8 86 / 8 / 8 86 / 8 / 8 84 / 8 / 8 82 / 8 / 8 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of June Primary Sales & Strategic, Marketing Director, Building 51
52 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 ipaclear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipaclear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB ipaclear Thermally toughened or Heat soaked thermally toughened AVCP characteristics in : Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 5,6 5,5 NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 91 / 8 / 8 90 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 88 / 8 / 8 87 / 8 / 8 86 / 8 / 8 86 / 8 / 8 84 / 8 / 8 82 / 8 / 8 81 / 8 / 8 NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS 2rd of June Primary Sales & Strategic, Marketing Director, Building 52
53 ipasol 5
54 CE Marking of Coated glass - EN :2004 ipasol bright neutral (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol bright neutral, intended to be used in buildings and construction works, following EN :2004 NB ipasol bright neutral characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 64 / 4 / 6 / 5 / 62 / 4 / 2 61 / 4 / 1 61 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 66 / 27 / 25 6 / 27 / 2 60 / 27 / / 26 / / 26 / 20 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 54
55 CE Marking of Coated glass - EN :2004 ipasol bright white (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol bright white, intended to be used in buildings and construction works, following EN :2004 NB ipasol bright white characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 65 / 5 / 4 65 / 5 / 4 64 / 5 / 4 64 / 5 / 4 64 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 27 / / 27 / / 27 / / 27 / / 27 / 25 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 55
56 CE Marking of Coated glass - EN :2004 ipasol neutral 50/27 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol neutral 50/27, intended to be used in buildings and construction works, following EN :2004 NB ipasol neutral 50/27 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,02 0,02 0,02 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 55 / 4 / 6 55 / 4 / 6 54 / 4 / 6 54 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 27 / 40 / / 40 / / 40 / 2 26 / 40 / 21 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 56
57 CE Marking of Coated glass - EN :2004 ipasol neutral 60/ (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol neutral 60/, intended to be used in buildings and construction works, following EN :2004 NB ipasol neutral 60/ characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 66 / 6 / 7 66 / 6 / 7 65 / 6 / 7 64 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 9 / 28 / 9 / 25 2 / 9 / 2 2 / 9 / 21 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 57
58 CE Marking of Coated glass - EN :2004 ipasol neutral 69/7 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol neutral 69/7, intended to be used in buildings and construction works, following EN :2004 NB ipasol neutral 69/7 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 76 / 6 / 7 75 / 6 / 7 75 / 6 / 7 74 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 4 / 1 7 / 4 / 28 7 / 4 / 26 6 / 4 / 24 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 58
59 CE Marking of Coated glass - EN :2004 ipasol neutral 70/9 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol neutral 70/9, intended to be used in buildings and construction works, following EN :2004 NB ipasol neutral 70/9 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 77 / 5 / 7 76 / 5 / 7 76 / 5 / 7 75 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 41 / 28 9 / 41 / 25 8 / 41 / 2 8 / 41 / 21 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 59
60 CE Marking of Coated glass - EN :2004 ipasol neutral 7/42 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol neutral 7/42, intended to be used in buildings and construction works, following EN :2004 NB ipasol neutral 7/42 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 4 / 5 80 / 4 / 5 79 / 4 / 5 78 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 6 / 25 4 / 6 / / 6 / / 6 / 18 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 60
61 CE Marking of Coated glass - EN :2004 ipasol platin 25/17 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol platin 25/17, intended to be used in buildings and construction works, following EN :2004 NB ipasol platin 25/17 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,02 0,02 0,02 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 27 / 0 / 6 27 / 0 / 6 26 / 0 / / 0 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 17 / 52 / / 52 / / 52 / / 52 / 57 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 61
62 CE Marking of Coated glass - EN :2004 ipasol platin 47/29 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol platin 47/29, intended to be used in buildings and construction works, following EN :2004 NB ipasol platin 47/29 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 51 / 26 / 8 50 / 26 / 7 50 / 26 / 7 49 / 26 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 50 / / 50 / 9 28 / 50 / 6 28 / 50 / 4 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 62
63 CE Marking of Coated glass - EN :2004 ipasol shine 40/22 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol shine 40/22, intended to be used in buildings and construction works, following EN :2004 NB ipasol shine 40/22 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 44 / 5 / / 5 / / 5 / 14 4 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 44 / / 44 / / 44 / / 44 / 22 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 6
64 CE Marking of Coated glass - EN :2004 ipasol sky 0/17 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol sky 0/17, intended to be used in buildings and construction works, following EN :2004 NB ipasol sky 0/17 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 4 / 17 / 4 / 17 2 / 4 / 17 2 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 15 / 45 / 2 15 / 45 / / 45 / / 45 / 18 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 64
65 CE Marking of Coated glass - EN :2004 ipasol ultraselect 62/29 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipasol ultraselect 62/29, intended to be used in buildings and construction works, following EN :2004 NB ipasol ultraselect 62/29 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / / 6 68 / / 6 68 / / 6 67 / / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 46 / 8 0 / 46 / 6 0 / 46 / 4 0 / 46 / 2 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 65
66 ipawhite 66
67 CE Marking of Float glass - EN 572-9:2004 ipawhite (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipawhite, intended to be used in buildings and construction works, following EN 572-9:2004 NB ipawhite characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 5,6 5,5 NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 90 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 88 / 8 / 8 87 / 8 / 8 NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS 2rd of June Primary Sales & Strategic, Marketing Director, Building 67
68 CE Marking of Heat strengthened glass - EN 186-2:2004 ipawhite Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipawhite Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB ipawhite Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 5,6 NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 88 / 8 / 8 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of June Primary Sales & Strategic, Marketing Director, Building 68
69 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 ipawhite Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named ipawhite Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB ipawhite Thermally toughened or Heat soaked thermally toughened AVCP characteristics in : Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 5,6 5,5 NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 90 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 88 / 8 / 8 87 / 8 / 8 NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS 2rd of June Primary Sales & Strategic, Marketing Director, Building 69
70 iplus 70
71 CE Marking of Coated glass - EN :2004 iplus Advanced 1.0 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Advanced 1.0, intended to be used in buildings and construction works, following EN :2004 NB iplus Advanced 1.0 characteristics in : AVCP Sytems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 8 / 10 8 / 8 / 10 8 / 8 / / 8 / / 8 / / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 54 / 6 / 29 5 / 6 / / 6 / / 6 / / 6 / / 6 / 20 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 71
72 CE Marking of Coated glass - EN :2004 iplus Advanced 1.0 on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Advanced 1.0 on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB iplus Advanced 1.0 on Clearvision characteristics in : AVCP Sytems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 8 / / 8 / / 8 / / 8 / / 8 / / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 57 / 6 / 5 57 / 6 / 5 56 / 6 / 5 56 / 6 / 4 56 / 6 / 56 / 6 / NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 72
73 CE Marking of Coated glass - EN :2004 iplus AF (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus AF, intended to be used in buildings and construction works, following EN :2004 NB iplus AF characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 12 / 12 8 / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 78 / 11 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 7
74 CE Marking of Heat strengthened glass - EN 186-2:2004 iplus AF Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus AF Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB iplus AF Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 12 / 12 8 / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 78 / 11 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 74
75 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 iplus AF Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus AF Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB iplus AF Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 12 / 12 8 / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 78 / 11 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 75
76 CE Marking of Coated glass - EN :2004 iplus AF Energy N (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus AF Energy N, intended to be used in buildings and construction works, following EN :2004 NB iplus AF Energy N characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 75 / 10 / / 10 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 42 / 1 9 / 42 / 29 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 76
77 CE Marking of Coated glass - EN :2004 iplus AF Top (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus AF Top, intended to be used in buildings and construction works, following EN :2004 NB iplus AF Top characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 9 / 10 8 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 60 / 29 / / 28 / 20 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 77
78 CE Marking of Coated glass EN :2004 iplus Energy N (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Energy N, intended to be used in buildings and construction works, following EN :2004 NB iplus Energy N characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 80 / 7 / 7 79 / 7 / 7 78 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 41 / 2 42 / 41 / / 41 / / 41 / 2 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 78
79 CE Marking of Coated glass EN :2004 iplus Energy N on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Energy N on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB iplus Energy N on Clearvision characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 7 / 7 82 / 7 / 7 82 / 7 / 7 82 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 41 / / 41 / / 41 / 8 44 / 41 / 7 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 79
80 CE Marking of Coated glass - EN :2004 iplus Energy NT (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Energy NT, intended to be used in buildings and construction works, following EN :2004 NB iplus Energy NT characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 80
81 CE Marking of Heat strengthened glass - EN 186-2:2004 iplus Energy NT Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Energy NT Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB iplus Energy NT Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 80 / 7 / 7 79 / 7 / 7 78 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 40 / 4 / 40 / / 40 / / 40 / 24 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 81
82 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 iplus Energy NT Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Energy NT Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB iplus Energy NT Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 80 / 7 / 7 79 / 7 / 7 78 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 40 / 4 / 40 / / 40 / / 40 / 24 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 82
83 CE Marking of Coated glass - EN :2004 iplus I-Top (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus I-Top, intended to be used in buildings and construction works, following EN :2004 NB iplus I-Top characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 6 / 7 87 / 6 / 7 86 / 6 / 7 86 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 29 / / 29 / / 29 / / 28 / 19 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 8
84 CE Marking of Coated glass - EN :2004 iplus I-Top on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus I-Top on clearvision, intended to be used in buildings and construction works, following EN :2004 NB iplus I-Top on Clearvision characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 6 / 7 89 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 6 / 29 / 29 6 / 29 / 29 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 84
85 CE Marking of Coated glass - EN :2004 iplus Light (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Light, intended to be used in buildings and construction works, following EN :2004 NB iplus Light characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 72 / 19 / / 19 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 4 / 4 42 / 4 / 0 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 85
86 CE Marking of Coated glass - EN :2004 iplus LS (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus LS, intended to be used in buildings and construction works, following EN :2004 NB iplus LS characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,08 0,08 0,08 0,08 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 6 / 6 90 / 6 / 6 89 / 6 / 6 89 / 6 / 6 88 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 18 / 16 7 / 18 / / 18 / / 18 / / 17 / 14 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 86
87 CE Marking of Coated glass - EN :2004 iplus LST (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus LST, intended to be used in buildings and construction works, following EN :2004 NB iplus LST characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 87
88 CE Marking of Heat strengthened glass - EN 186-2:2004 iplus LST Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus LST Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB iplus LST Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,08 0,08 0,08 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 6 / 6 89 / 6 / 6 89 / 6 / 6 88 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 18 / / 18 / / 18 / / 17 / 14 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 88
89 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 iplus LST Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus LST Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB iplus LST Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,08 0,08 0,08 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 6 / 6 89 / 6 / 6 89 / 6 / 6 88 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 18 / / 18 / / 18 / / 17 / 14 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 89
90 CE Marking of Coated glass - EN :2004 iplus Top 1.0 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.0, intended to be used in buildings and construction works, following EN :2004 NB iplus top 1.0 characteristics in : AVCP Systems mm 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 77 / 15 / / 15 / / 15 / / 15 / / 15 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 48 / 42 / 9 47 / 42 / 8 46 / 42 / 5 45 / 42 / 2 44 / 42 / 0 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 90
91 CE Marking of Coated glass - EN :2004 iplus Top 1.1 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.1, intended to be used in buildings and construction works, following EN :2004 NB iplus Top 1.1 characteristics in : AVCP Sytems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 5 / 6 88 / 5 / 6 88 / 5 / 6 87 / 5 / 6 85 / 5 / 6 84 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 6 / 27 / / 26 / / 26 / / 26 / / 26 / / 26 / 15 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 91
92 CE Marking of Coated glass - EN :2004 iplus Top 1.1 on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.1 on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB iplus Top 1.1 on Clearvision characteristics in : AVCP Sytems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 5 / 6 91 / 5 / 6 91 / 5 / 6 91 / 5 / 6 91 / 5 / 6 91 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 67 / 27 / / 27 / / 27 / / 27 / / 27 / / 27 / 24 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 92
93 CE Marking of Coated glass - EN :2004 iplus Top 1.1T (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.1T, intended to be used in buildings and construction works, following EN :2004 NB iplus Top 1.1T characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 9
94 CE Marking of Heat strengthened glass - EN 186-2:2004 iplus Top 1.1T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.1T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB iplus Top 1.1T Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 5 / 5 89 / 5 / 5 89 / 5 / 5 87 / 5 / 5 86 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 65 / 25 / / 25 / 19 6 / 25 / / 24 / / 24 / 15 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 94
95 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 iplus Top 1.1T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.1T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB iplus Top 1.1T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 5 / 5 89 / 5 / 5 89 / 5 / 5 87 / 5 / 5 86 / 4 / 5 85 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 65 / 25 / / 25 / 19 6 / 25 / / 24 / / 24 / / 24 / 14 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 95
96 CE Marking of Coated glass - EN :2004 iplus Top 1.1T on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.1T on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB iplus Top 1.1T on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 96
97 CE Marking of Heat strengthened glass - EN 186-2:2004 iplus Top 1.1T on Clearvision Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.1T on Clearvision Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB iplus Top 1.1T on Clearvision Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 5 / 5 92 / 5 / 5 92 / 5 / 5 92 / 5 / 5 92 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 25 / / 25 / / 25 / 2 69 / 25 / 2 69 / 25 / 22 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 97
98 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 iplus Top 1.1T on Clearvision Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Top 1.1T on Clearvision Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB iplus Top 1.1T on Clearvision Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 5 / 5 92 / 5 / 5 92 / 5 / 5 92 / 5 / 5 92 / 5 / 5 91 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 25 / / 25 / / 25 / 2 69 / 25 / 2 69 / 25 / / 25 / 22 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 98
99 CE Marking of Coated glass - EN :2004 iplus Twin Top (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Twin Top, intended to be used in buildings and construction works, following EN :2004 NB iplus Twin Top characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 9 / 10 8 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 60 / 29 / / 28 / 20 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 99
100 CE Marking of Coated glass - EN :2004 iplus 1.0 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus 1.0, intended to be used in buildings and construction works, following EN :2004 NB iplus 1.0 characteristics in : AVCP Sytems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 12 / / 12 / / 12 / / 12 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 52 / 9 / 51 / 9 / 2 50 / 9 / 0 49 / 9 / / 9 / 26 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 100
101 CE Marking of Coated glass - EN :2004 iplus Alpha N (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Alpha N, intended to be used in buildings and construction works, following EN :2004 NB iplus Alpha N characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,06 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 5 / 5 89 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 72 / 19 / / 19 / 16 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 101
102 CE Marking of Heat strengthened glass - EN 186-2:2004 iplus Alpha N Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Alpha N Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB iplus Alpha N Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 5 / 5 89 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 72 / 19 / / 19 / 16 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 102
103 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 iplus Alpha N Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Alpha N Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB iplus Alpha N Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 5 / 5 89 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 72 / 19 / / 19 / 16 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 10
104 CE Marking of Coated glass - EN :2004 iplus E (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus E, intended to be used in buildings and construction works, following EN :2004 NB iplus E characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 5 / 6 88 / 5 / 6 88 / 5 / 5 87 / 5 / 5 86 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 62 / 27 / / 27 / / 27 / / 27 / / 27 / 16 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 104
105 CE Marking of Coated glass - EN :2004 iplus ET (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus ET, intended to be used in buildings and construction works, following EN :2004 NB iplus ET characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 105
106 CE Marking of Heat strengthened glass - EN 186-2:2004 iplus ET Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus ET Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB iplus ET Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 7 / 8 86 / 7 / 8 85 / 7 / 8 84 / 7 / 8 8 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 0 / / 0 / / 0 / 2 56 / 0 / / 0 / 19 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 106
107 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 iplus ET Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus ET Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB iplus ET Thermally toughened or Heat soaked thermally toughened AVCP characteristics in : Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K NPD 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 7 / 8 86 / 7 / 8 85 / 7 / 8 84 / 7 / 8 8 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 0 / / 0 / / 0 / 2 56 / 0 / / 0 / 19 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 107
108 CE Marking of Coated glass - EN :2004 iplus Twin E (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named iplus Twin E, intended to be used in buildings and construction works, following EN :2004 NB iplus Twin E characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 9 / / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 29 / / 29 / 20 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 108
109 Lacobel T 109
110 CE Marking of Heat strengthened glass - EN 186-2:2004 Lacobel T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Lacobel T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Lacobel T Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 110
111 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Lacobel T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Lacobel T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Lacobel T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 111
112 Mirox G 112
113 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox G Clear Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox G Clear, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox G Clear characteristics in : AVCP Systems 2 mm mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 11
114 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox G Clearvision Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox G Clearvision, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox G Clearvision characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 114
115 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox G Black Mirox Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox G Black Mirox, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox G Black Mirox characteristics in : AVCP Systems 4 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 115
116 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox G Bronze Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox G Bronze, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox G Bronze characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 116
117 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox G Green Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox G Green, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox G Green characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 117
118 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox G Grey Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox G Grey, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox G Grey characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 118
119 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox G PrivaBlue Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox G PrivaBlue, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox G PrivaBlue characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 119
120 Mirox MNGE 120
121 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox MNGE Clear Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox MNGE Clear, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox MNGE Clear characteristics in : AVCP Systems 2 mm mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 121
122 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox MNGE Clearvision Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox MNGE Clearvision, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox MNGE Clearvision characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 122
123 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox MNGE Black Mirox Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox MNGE Black Mirox, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox MNGE Black Mirox characteristics in : AVCP Systems 4 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 12
124 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox MNGE Bronze Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox MNGE Bronze, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox MNGE Bronze characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 124
125 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox MNGE Green Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox MNGE Green, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox MNGE Green characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 125
126 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox MNGE Grey Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox MNGE Grey, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox MNGE Grey characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 126
127 CE Marking of Mirrors from silver-coated float glass for internal use EN 106-2:2008 Mirox MNGE PrivaBlue Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Mirox MNGE PrivaBlue, intended to be used in buildings and construction works, following EN 106-2:2008 NB Mirox MNGE PrivaBlue characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 11. U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 127
128 Planibel clear 128
129 CE Marking of Float glass - EN 572-9:2004 Planibel clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clear, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel clear characteristics in : AVCP Systems 2 mm mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 88 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 88 / 8 / 8 86 / 8 / 8 84 / 8 / 8 8 / 7 / 7 81 / 7 / 7 78 / 7 / Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 129
130 CE Marking of Float glass - EN 572-9:2004 Planibel clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clear, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel clear characteristics in : AVCP Systems 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-2;-) 5 (-2;-) U-value (EN 67) 5,6 5,6 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 8 / 8 86 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 75 / 7 / 7 72 / 7 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 10
131 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel clear Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clear Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel clear Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 88 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 84 / 8 / 8 8 / 7 / 7 81 / 7 / 7 78 / 7 / 7 75 / 7 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 11
132 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel clear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel clear Thermally toughened or Heat soaked thermally AVCP toughened characteristics in : Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 5,6 5,6 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 88 / 8 / 8 87 / 8 / 8 86 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 86 / 8 / 8 84 / 8 / 8 8 / 7 / 7 81 / 7 / 7 78 / 7 / 7 75 / 7 / 7 72 / 7 / Durability PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 12
133 CE Marking of Float glass - EN 572-9:2004 Planibel Linea Azzurra (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Linea Azzurra, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Linea Azzurra characteristics in : AVCP Systems 8 mm 10 mm 12 mm 15 mm 19 mm 25 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-2) 4 (-2;-) 5 (-2;-) NPD NPD NPD U-value (EN 67) 5,7 5,6 5,6 5,4 5,4 5,2 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 8 / 8 86 / 8 / 8 85 / 8 / 8 8 / 8 / 8 81 / 7 / 7 78 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 7 / 7 69 / 6 / 6 66 / 6 / 6 61 / 6 / 6 56 / 6 / 6 50 / 6 / Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 1
134 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Linea Azzurra Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Linea Azzurra Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Linea Azzurra Heat strengthened characteristics in : AVCP Systems 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,7 5,6 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 8 / 8 86 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 7 / 7 69 / 6 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 14
135 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Linea Azzurra Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Linea Azzurra Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Linea Azzurra Thermally toughened or Heat soaked thermally AVCP toughened characteristics in : Systems 8 mm 10 mm 12 mm 15 mm 19 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C1 1C1 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-2) 4 (-2;-) 5 (-2;-) NPD NPD U-value (EN 67) 5,7 5,6 5,6 5,5 5,4 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 8 / 8 86 / 8 / 8 85 / 8 / 8 8 / 8 / 8 81 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 7 / 7 69 / 6 / 6 66 / 6 / 6 61 / 6 / 6 56 / 6 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 15
136 CE Marking of Float glass - EN 572-9:2004 Planibel Clearvision, Sunmax, Sunmax Premium (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clearvision, Sunmax, Sunmax Premium, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Clearvision, Sunmax, Sunmax Premium characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 8 / 8 92 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 91 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 16
137 CE Marking of Float glass - EN 572-9:2004 Planibel Clearvision, Sunmax, Sunmax Premium (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clearvision, Sunmax, Sunmax Premium, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Clearvision, Sunmax, Sunmax Premium characteristics in : AVCP Systems 10 mm 12 mm 15 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-2;-) 5 (-2;-) NPD U-value (EN 67) 5,6 5,6 5,5 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 90 / 8 / 8 89 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 89 / 8 / 8 86 / 8 / 8 85 / 8 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 17
138 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Clearvision, Sunmax, Sunmax Premium Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clearvision, Sunmax, Sunmax Premium, Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Clearvision, Sunmax, Sunmax Premium Heat strengthened AVCP 4 mm 5 mm 6 mm 8 mm 10 mm characteristics in : Systems 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 18
139 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Clearvision, Sunmax, Sunmax Premium Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clearvision, Sunmax, Sunmax Premium, Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Clearvision, Sunmax, Sunmax Premium Thermally toughened or AVCP Heat soaked thermally toughened characteristics in Systems mm 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD 1C 1C 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 8 / 8 92 / 8 / 8 91 / 8 / 8 91 / 8 / 8 91 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 91 / 8 / 8 90 / 8 / 8 90 / 8 / 8 89 / 8 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 19
140 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Clearvision, Sunmax, Sunmax Premium Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clearvision, Sunmax, Sunmax Premium, Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Clearvision, Sunmax, Sunmax Premium Thermally toughened or AVCP Heat soaked thermally toughened characteristics in Systems 10 mm 12 mm 15 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C1 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-2;-) 5 (-2;-) NPD U-value (EN 67) 5,6 5,6 5,5 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 90 / 8 / 8 89 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 89 / 8 / 8 86 / 8 / 8 85 / 8 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 140
141 CE Marking of Float glass - EN 572-9:2004 Planibel Clear Plus (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Clear Plus intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Clear Plus characteristics in : AVCP Systems 4 mm 1. Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 A1. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) U-value (EN 67) 5,8 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 141
142 Planibel coloured 142
143 CE Marking of Float glass - EN 572-9:2004 Planibel Azur (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Azur, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Azur characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 79 / 7 / 7 7 / 7 / 7 68 / 6 / 6 6 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 6 / 6 49 / 6 / 6 42 / 5 / 5 6 / 5 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 14
144 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Azur Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Azur Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Azur Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 79 / 7 / 7 7 / 7 / 7 68 / 6 / 6 6 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 6 / 6 49 / 6 / 6 42 / 5 / 5 6 / 5 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 144
145 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Azur Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Azur Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Azur Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 79 / 7 / 7 7 / 7 / 7 68 / 6 / 6 6 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 6 / 6 49 / 6 / 6 42 / 5 / 5 6 / 5 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 145
146 CE Marking of Float glass - EN 572-9:2004 Planibel Bronze (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Bronze, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Bronze characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 6 / 6 62 / 6 / 6 56 / 6 / 6 51 / 6 / 6 41 / 5 / 5 4 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 67 / 6 / 6 61 / 6 / 6 56 / 6 / 6 50 / 5 / 5 42 / 5 / 5 4 / 5 / Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 146
147 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Bronze Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Bronze Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Bronze Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 62 / 6 / 6 56 / 6 / 6 51 / 6 / 6 41 / 5 / 5 4 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 61 / 6 / 6 56 / 6 / 6 50 / 5 / 5 42 / 5 / 5 4 / 5 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 147
148 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Bronze Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Bronze Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Bronze Thermally toughened or Heat soaked thermally AVCP toughened characteristics in : Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 6 / 6 62 / 6 / 6 56 / 6 / 6 51 / 6 / 6 41 / 5 / 5 4 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 67 / 6 / 6 61 / 6 / 6 56 / 6 / 6 50 / 5 / 5 42 / 5 / 5 4 / 5 / Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 148
149 CE Marking of Float glass - EN 572-9:2004 Planibel Dark Blue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Dark Blue, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Dark Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,7 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 6 / 6 58 / 6 / 6 50 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 52 / 6 / 6 41 / 5 / 5 / 5 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 149
150 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Dark Blue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Dark Blue Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Dark Blue Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,7 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 6 / 6 57 / 6 / 6 50 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 52 / 6 / 6 41 / 5 / 5 / 5 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 150
151 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Dark Blue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Dark Blue Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Dark Blue Thermally toughened or Heat soaked thermally AVCP Systems 4 mm toughened characteristics in : 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,7 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 6 / 6 57 / 6 / 6 50 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 52 / 6 / 6 41 / 5 / 5 / 5 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 151
152 CE Marking of Float glass - EN 572-9:2004 Planibel Dark Grey (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Dark Grey, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Dark Grey characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 18 / 4 / 4 8 / 4 / 4 4/ 4 / 4 2/ 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 18 / 4 / 4 8 / 4 / 4 4/ 4 / 4 2/ 4 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 152
153 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Dark Grey Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Dark Grey Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Dark Grey Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 18 / 4 / 4 8 / 4 / 4 4/ 4 / 4 2/ 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 18 / 4 / 4 8 / 4 / 4 4/ 4 / 4 2/ 4 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 15
154 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Dark Grey Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Dark Grey Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Dark Grey Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 18 / 4 / 4 8 / 4 / 4 4/ 4 / 4 2/ 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 18 / 4 / 4 8 / 4 / 4 4/ 4 / 4 2/ 4 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 154
155 CE Marking of Float glass - EN 572-9:2004 Planibel Green (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Green, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Green characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 79 / 7 / 7 76 / 7 / 7 7 / 7 / 7 68 / 6 / 6 6 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 6 / 6 54 / 6 / 6 49 / 6 / 6 44 / 5 / 5 7 / 5 / 5 1 / 5 / Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 155
156 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Green Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Green Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Green Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 79 / 7 / 7 76 / 7 / 7 7 / 7 / 7 68 / 6 / 6 6 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 54 / 6 / 6 49 / 6 / 6 44 / 5 / 5 7 / 5 / 5 1 / 5 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 156
157 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Green Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Green Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Green Thermally toughened or Heat soaked thermally AVCP toughened characteristics in : Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 79 / 7 / 7 76 / 7 / 7 7 / 7 / 7 68 / 6 / 6 6 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 6 / 6 54 / 6 / 6 49 / 6 / 6 44 / 5 / 5 7 / 5 / 5 1 / 5 / Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 157
158 CE Marking of Float glass - EN 572-9:2004 Planibel Grey (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Grey, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel Grey characteristics in : AVCP Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 5,6 5,6 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 6 / 6 / 6 57 / 6 / 6 50 / 5 / 5 44 / 5 / 5 4 / 5 / 5 27 / 5 / 5 21 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 64 / 6 / 6 58 / 6 / 6 52 / 6 / 6 46 / 5 / 5 7 / 5 / 5 0 / 5 / 5 24 / 4 / Durability PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 158
159 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Grey Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Grey Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Grey Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 57 / 6 / 6 50 / 5 / 5 44 / 5 / 5 4 / 5 / 5 27 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 58 / 6 / 6 52 / 6 / 6 46 / 5 / 5 7 / 5 / 5 0 / 5 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 159
160 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Grey Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Grey Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Grey Thermally toughened or Heat soaked AVCP thermally toughened characteristics in : Systems mm 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) 5,8 5,8 5,8 5,7 5,7 5,6 5,6 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 6 / 6 / 6 57 / 6 / 6 50 / 5 / 5 44 / 5 / 5 4 / 5 / 5 27 / 5 / 5 21 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 64 / 6 / 6 58 / 6 / 6 52 / 6 / 6 46 / 5 / 5 7 / 5 / 5 0 / 5 / 5 24 / 4 / Durability PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 160
161 CE Marking of Float glass - EN 572-9:2004 Planibel PrivaBlue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel PrivaBlue, intended to be used in buildings and construction works, following EN 572-9:2004 NB Planibel PrivaBlue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48 / 5 / 5 5 / 5 / 5 25 / 5 / 5 18 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 5 / 5 20 / 4 / 4 14 / 4 / 4 10 / 4 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 161
162 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel PrivaBlue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel PrivaBlue Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel PrivaBlue Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48 / 5 / 5 5 / 5 / 5 25 / 5 / 5 18 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 5 / 5 20 / 4 / 4 14 / 4 / 4 10 / 4 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 162
163 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel PrivaBlue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel PrivaBlue Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel PrivaBlue Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48 / 5 / 5 5 / 5 / 5 25 / 5 / 5 18 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 5 / 5 20 / 4 / 4 14 / 4 / 4 10 / 4 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 16
164 Planibel low-e 164
165 CE Marking of Coated glass - EN :2004 Planibel A (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel A, intended to be used in buildings and construction works, following EN :2004 NB Planibel A characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,10 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 80 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 68 / 12 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 165
166 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel A Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel A Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel A Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 80 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 68 / 12 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 166
167 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel A Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel A Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel A Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 80 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 68 / 12 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 167
168 CE Marking of Coated glass - EN :2004 Planibel G (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel G, intended to be used in buildings and construction works, following EN :2004 NB Planibel G characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,14 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 11 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 168
169 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel G Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel G Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel G Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 11 / / 11 / 10 NPD NPD 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 169
170 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel G Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel G Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel G Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 11 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 170
171 CE Marking of Coated glass - EN :2004 Planibel G fast (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel G fast, intended to be used in buildings and construction works, following EN :2004 NB Planibel G fast characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,14 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 11 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 171
172 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel G fast Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel G fast Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel G fast Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 11 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 172
173 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel G fast Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel G fast Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel G fast Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 11 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 11 / / 11 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 17
174 CE Marking of Coated glass - EN :2004 Planibel Hortiplus N (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Hortiplus N, intended to be used in buildings and construction works, following EN :2004 NB Planibel Hortiplus N characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,15 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 12 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 12 / / 12 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 174
175 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Hortiplus N Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Hortiplus N Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Hortiplus N Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 12 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 12 / / 12 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 175
176 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Hortiplus N Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Hortiplus N Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Hortiplus N Thermally toughened or Heat soaked thermally AVCP Systems 4 mm 6 mm toughened characteristics in : 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 12 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 12 / / 12 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 176
177 CE Marking of Coated glass - EN :2004 AF iplus E (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named AF iplus E, intended to be used in buildings and construction works, following EN :2004 NB AF iplus E characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 9 / / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 29 / / 29 / 21 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 177
178 CE Marking of Coated glass - EN :2004 Planibel AF Top N+ (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel AF Top N+, intended to be used in buildings and construction works, following EN :2004 NB Planibel AF Top N+ characteristics in : AVCP Systems 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 10 / / 10 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 56 / 1 / / 1 / 2 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 178
179 CE Marking of Coated glass - EN :2004 Planibel Top N (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Top N, intended to be used in buildings and construction works, following EN :2004 NB Planibel Top N characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 6 / 8 87 / 6 / 8 87 / 6 / 8 86 / 6 / 8 86 / 6 / 8 85 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 64 / 25 / 2 6 / 25 / 22 6 / 25 / / 25 / / 25 / / 25 / 19 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 179
180 CE Marking of Coated glass - EN :2004 Planibel Top N+ (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Top N+, intended to be used in buildings and construction works, following EN :2004 NB Planibel Top N+ characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 6 / 8 86 / 6 / 8 86 / 6 / 7 85 / 6 / 7 84 / 6 / 7 8 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 29 / / 29 / / 29 / 2 56 / 29 / / 29 / / 29 / 17 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 180
181 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Top NT Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Top NT Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Top NT Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,05 0,05 0,05 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 6 / 6 87 / 6 / 6 86 / 6 / 6 85 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 67 / 21 / / 21 / / 21 / / 21 / 14 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 181
182 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Top NT Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Top NT Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Top NT Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,05 0,05 0,05 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 6 / 6 87 / 6 / 6 86 / 6 / 6 85 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 67 / 21 / / 21 / / 21 / / 21 / 14 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 182
183 CE Marking of Coated glass - EN :2004 Planibel Top N+T (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Top N+T, intended to be used in buildings and construction works, following EN :2004 NB Planibel Top N+T characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 18
184 CE Marking of Heat strengthened glass - EN 186-2:2004 Planibel Top N+T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Top N+T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Planibel Top N+T Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 8 / 6 87 / 8 / 6 86 / 8 / 6 85 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 65 / 25 / 22 6 / 25 / / 25 / / 25 / 17 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 184
185 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Planibel Top N+T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Top N+T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Planibel Top N+T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 8 / 6 87 / 8 / 6 86 / 8 / 6 85 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 65 / 25 / 22 6 / 25 / / 25 / / 25 / 17 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 185
186 CE Marking of Coated glass - EN :2004 Planibel Tri (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Tri, intended to be used in buildings and construction works, following EN :2004 NB Planibel Tri characteristics in : AVCP Systems mm 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD 0,07 0,07 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 8 / 8 88 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 72 / 17 / / 17 / / 17 / 14 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 186
187 CE Marking of Coated glass - EN :2004 Planibel Tri on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Tri on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Planibel Tri on Clearvision characteristics in : AVCP Systems mm 4 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 1 (-2;-) U-value (EN 67) NPD NPD NPD 0,07 0,07 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 7 / 8 89 / 7 / 8 89 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 75 / 18 / / 18 / / 17 / 17 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 187
188 Polished wired glass 188
189 CE Marking of Polished wired glass - EN 572-9:2004 Polished wired glass Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Polished wired glass, intended to be used in buildings and construction works, following EN 572-9:2004 NB Polished wired glass characteristics in : AVCP Systems 6 mm Polished wired glass J 6 mm Polished wired glass Safety J 1. Resistance to fire (EN ) 1 E0 E0 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD B 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 1 (-2;-) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 80 / 8 / 8 80 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 7 / 7 70 / 7 / 7 NDP NDP 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 189
190 Pyrobelite / Pyrobel 190
191 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobelite Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobelite, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobelite characteristics in : AVCP Systems Pyrobelite 7 Pyrobelite 7 EG Pyrobelite 9 EG 1. Resistance to fire (EN ) 1 EW0 EW0 EI20 / EW0 2. Reaction to fire (EN ), 4 A2 s1, d0 NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) B 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (0; -) 5 (-1; -2) 7 (-1;-2) U-value (EN 67) 5,7 5,5 5,5 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 8 / 8 87 / 8 / 8 86 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 7 / 7 65 / 7 / 7 6 / 6 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 191
192 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobelite Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobelite, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobelite characteristics in : AVCP Systems Pyrobelite 10 Pyrobelite Resistance to fire (EN ) 1 EW0 EW0 2. Reaction to fire (EN ), 4 A2 s1, d0 NPD. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 7 (-1;-) 5 (-1; -2) U-value (EN 67) 5,6 5,5 NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 68 / 7 / 7 65 / 7 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 192
193 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobelite Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobelite, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobelite characteristics in : AVCP Systems Pyrobelite 12 Pyrobelite 12 EG Pyrobelite 1 1. Resistance to fire (EN ) 1 EI20 / EW60 EI20 / EW60 EW0 2. Reaction to fire (EN ), 4 A2 s1, d0 NPD A2 s1, d0. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 6 (-1; -) 8 (-1; -) 7 (-1; -2) U-value (EN 67) 5,6 5,4 5,5 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 8 / 8 85 / 8 / 8 86 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 65 / 7 / 7 58 / 6 / 6 65 / 6 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 19
194 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 8 Pyrobel 8 EG Pyrobel Resistance to fire (EN ) 1 EI15 / EW0 EI15 / EW0 EI0 / EW60 2. Reaction to fire (EN ), 4 A2 s1, d0 NPD A2 s1, d0. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD 1B1 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1; -) 6 (-1; -) 9 (-1; -) U-value (EN 67) 5,6 5,4 5,4 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 8 / 8 86 / 8 / 8 84 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 7 / 7 62 / 6 / 6 60 / 6 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 194
195 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 16 EG Pyrobel 17 Pyrobel 17 EG 1. Resistance to fire (EN ) 1 EI0 / EW60 EI45 EI45 2. Reaction to fire (EN ), 4 NPD A2 s1, d0 NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 2B2 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 9 (-1; -) 7 (-1; -) 8 (0; -) U-value (EN 67) 5,2 5,4 5,2 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 7 / 7 84 / 8 / 8 84 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 54 / 6 / 6 61 / 6 / 6 56 / 6 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 195
196 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 17N Pyrobel 17N EG Pyrobel Resistance to fire (EN ) 1 EI45 / EW60 EI45 / EW60 EI45 / EW60 2. Reaction to fire (EN ), 4 A2 s1, d0 NPD A2 s1, d0. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 9 (0; -) 40 (-1; -) 8 (0; -) U-value (EN 67) 5,4 5,2 5, NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 8 / 8 85 / 8 / 8 82 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 67 / 7 / 7 60 / 7 / 7 59 / 6 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 196
197 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 21 EG Pyrobel 2 Pyrobel 2 EG 1. Resistance to fire (EN ) 1 EI45 / EW60 EI60 EI60 2. Reaction to fire (EN ), 4 NPD A2 s1, d0 NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 40 (-1; -) 40 (-1; -) 4 (-1; -4) U-value (EN 67) 5,1 5,2 5,0 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 81 / 7 / 7 80 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 54 / 6 / 6 5 / 6 / 6 48 / 6 / 6 61 NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 197
198 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 25 Pyrobel 25 EG Pyrobel 0 1. Resistance to fire (EN ) 1 EI60 EI60 EI90 2. Reaction to fire (EN ), 4 A2 s1, d0 NPD A2 s1, d0. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 40 (-1; -) 4 (-1; -4) 42 (-1; -4) U-value (EN 67) 5,2 5,0 5,1 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 80 / 7 / 7 8 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 5 / 6 / 6 48 / 6 / 6 59 / 7 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 198
199 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 0 EG Pyrobel 5 Pyrobel 5 EG 1. Resistance to fire (EN ) 1 EI90 EI90 EI90 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1; -4) 41 (-1; -4) 42 (-1; -4) U-value (EN 67) 4,9 4,9 4,8 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 8 / 8 79 / 7 / 7 77 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 5 / 6 / 6 49 / 6 / 6 46 / 6 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 199
200 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 5 Pyrobel 5 EG Pyrobel 5N 1. Resistance to fire (EN ) 1 EI120 EI120 EI Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 45 (-1; -4) 46 (-2; -5) 48 (-2; -7) U-value (EN 67) 4,5 4, 4,5 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 72 / 7 / 7 71 / 7 / 7 75 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 5 / 5 8 / 5 / 5 42 / 5 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 200
201 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 5N EG 1. Resistance to fire (EN ) 1 EI Reaction to fire (EN ), 4 NPD. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 49 (-2; -7) U-value (EN 67) 4,4 NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 7 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 5 / Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 201
202 CE Marking of Pyrobel EN 14449: AC:2005 Pyrobel Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyrobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Pyrobel characteristics in : AVCP Systems Pyrobel 19H Pyrobel 2H Pyrobel 28H 1. Resistance to fire (EN ) 1 EI0 EI45 EI60 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 8 (-1; -) 9 (0; -) 41 (0;-) U-value (EN 67) 5,2 5,0 4,9 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 80 / 7 / 7 78 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 5 / 6 / 6 49 / 6 / 6 47 / 6 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 202
203 Pyropane 20
204 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Pyropane 100 Pyropane 110 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyropane, intended to be used in buildings and construction works, following EN :2005 NB Pyropane characteristics in : AVCP Systems Pyropane 100 Pyropane Resistance to fire (EN ) 1 E0 E0 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2; -) 1 (-2; -) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 89 / 8 / 8 NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 81 / 7 / 7 NPD NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 204
205 CE Marking of Static Smoke Barrier - EN Pyropane 100 SB 0 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the static smoke barrier product named Pyropane, intended to be used in buildings and construction works, following EN NB Pyropane characteristics in : AVCP Systems Pyropane 100 SB0 1. Resistance to fire classification 1 DH 0 2. Response delay 4 NPD. Openings, gaps and perimeter spaces : Gap head Gap edge Gap joint Area head Area edge Area joint 4 10 mm 11 mm 6 mm NPD NPD NPD 4. Maximum barrier permeability 4 NPD 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 205
206 CE Marking of Insulating glass unit EN : A2:2010 Pyropane ; /100 ; ; 201 ; 201/100 ; 202 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyropane, intended to be used in buildings and construction works, following EN : A2:2010 NB Pyropane characteristics in : AVCP Systems Pyropane Pyropane /100 Pyropane Pyropane 201 Pyropane 201/100 Pyropane Resistance to fire (EN ) 1 E0 EW0 E0 EW0 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) 8. Resistance against sudden temperature change and temperature differentials 4 9. Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) For 12 characteristics, see For 12 characteristics, see Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 206
207 CE Marking of Insulating glass unit EN : A2:2010 Pyropane Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyropane, intended to be used in buildings and construction works, following EN : A2:2010 NB Pyropane characteristics in : AVCP Systems Pyropane Resistance to fire (EN ) 1 E0/60 EW0/60 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) 8. Resistance against sudden temperature change and temperature differentials 4 9. Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) For 12 characteristics, see Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 207
208 CE Marking of Insulating glass unit EN : A2:2010 Pyropane Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyropane, intended to be used in buildings and construction works, following EN : A2:2010 NB Pyropane characteristics in : AVCP Systems Pyropane Resistance to fire (EN ) 1 E0/60 EW0/60 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) 8. Resistance against sudden temperature change and temperature differentials 4 9. Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) For 12 characteristics, see Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 208
209 CE Marking of Insulating glass unit EN : A2:2010 Pyropane Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyropane, intended to be used in buildings and construction works, following EN : A2:2010 NB Pyropane characteristics in : AVCP Systems Pyropane Resistance to fire (EN ) 1 E0 EW0 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) 8. Resistance against sudden temperature change and temperature differentials 4 9. Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) For 12 characteristics, see Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 209
210 CE Marking of Insulating glass unit EN : A2:2010 Pyropane Pyropane 204 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Pyropane, intended to be used in buildings and construction works, following EN : A2:2010 NB Pyropane characteristics in : AVCP Systems Pyropane Pyropane Resistance to fire (EN ) 1 E0 EW0 E0 EW0 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) 8. Resistance against sudden temperature change and temperature differentials 4 9. Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) For 12 characteristics, see For 12 characteristics, see Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 210
211 Solar patterned glass 211
212 CE Marking of Patterned glass - EN 572-9:2004 Astralite (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Astralite, intended to be used in buildings and construction works, following EN 572-9:2004 NB Astralite characteristics in : AVCP Systems,2 mm 4 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 91 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 90 / 8 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 212
213 CE Marking of Thermally toughened glass - EN :2004 Astralite Thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Astralite Thermally toughened, intended to be used in buildings and construction works, following EN :2004 NB Astralite Thermally toughened characteristics in : AVCP Systems,2 mm 4 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 91 / 8 / 8 91 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 90 / 8 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 21
214 CE Marking of Patterned glass - EN 572-9:2004 Solatex (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Solatex, intended to be used in buildings and construction works, following EN 572-9:2004 NB Solatex characteristics in : AVCP Systems,2 mm 4 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 8 / 8 92 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 91 / 8 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 214
215 CE Marking of Thermally toughened glass - EN :2004 Solatex Thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Solatex Thermally toughened, intended to be used in buildings and construction works, following EN :2004 NB Solatex Thermally toughened characteristics in : AVCP Systems,2 mm 4 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 8 / 8 92 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 91 / 8 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 215
216 CE Marking of Patterned glass - EN 572-9:2004 Solite (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Solite, intended to be used in buildings and construction works, following EN 572-9:2004 NB Solite characteristics in : AVCP Systems,2 mm 4 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 8 / 8 92 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 91 / 8 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 216
217 CE Marking of Thermally toughened glass - EN :2004 Solite Thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Solite Thermally toughened, intended to be used in buildings and construction works, following EN :2004 NB Solite Thermally toughened characteristics in : AVCP Systems,2 mm 4 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD U-value (EN 67) 5,8 5,8 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 92 / 8 / 8 92 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 91 / 8 / 8 91 / 8 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 217
218 Stopray 218
219 CE Marking of Coated glass - EN :2004 Stopray Indigo 48T (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Indigo 48T, intended to be used in buildings and construction works, following EN :2004 NB Stopray Indigo 48T characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 219
220 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopray Indigo 48T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Indigo 48T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopray Indigo 48T Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 5 / 5 / 6 46 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 8 / 8 2 / 8 / 6 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 220
221 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopray Indigo 48T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Indigo 48T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopray Indigo 48T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 5 / 5 / 6 46 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 8 / 8 2 / 8 / Durability 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 221
222 CE Marking of Coated glass - EN :2004 Stopray Lime 61T (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Lime 61T, intended to be used in buildings and construction works, following EN :2004 NB Stopray Lime 61T characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 222
223 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopray Lime 61T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Lime 61T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopray Lime 61T Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 6 / 6 6 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 8 / 9 0 / 8 / 7 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 22
224 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopray Lime 61T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Lime 61T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopray Lime 61T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 6 / 6 6 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 8 / 9 0 / 8 / 7 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 224
225 CE Marking of Coated glass - EN :2004 Stopray Silver (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Silver, intended to be used in buildings and construction works, following EN :2004 NB Stopray Silver characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 47 / 42 / / 42 / / 42 / / 42 / / 42 / / 42 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 27 / 61 / / 61 / / 61 / / 60 / / 60 / / 60 / 9 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 225
226 CE Marking of Coated glass - EN :2004 Stopray Silver Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Silver, intended to be used in buildings and construction works, following EN :2004 NB Stopray Silver characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 47 / 42 / / 42 / / 42 / / 42 / / 42 / / 42 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 27 / 61 / / 61 / / 61 / / 60 / / 60 / / 60 / 9 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 226
227 CE Marking of Coated glass - EN :2004 Stopray Silver Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Silver, intended to be used in buildings and construction works, following EN :2004 NB Stopray Silver characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 47 / 42 / / 42 / / 42 / / 42 / / 42 / / 42 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 27 / 61 / / 61 / / 61 / / 60 / / 60 / / 60 / 9 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 227
228 CE Marking of Coated glass - EN :2004 Stopray Silver on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Silver on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Silver on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48/42/48 48/42/48 48/42/48 48/42/48 47/42/47 47/42/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 29/61/6 29/61/62 29/61/61 29/61/60 28/61/58 28/61/57 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 228
229 CE Marking of Coated glass - EN :2004 Stopray Silver on Clearvision Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Silver on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Silver on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48/42/48 48/42/48 48/42/48 48/42/48 47/42/47 47/42/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 29/61/6 29/61/62 29/61/61 29/61/60 28/61/58 28/61/57 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 229
230 CE Marking of Coated glass - EN :2004 Stopray Silver on Clearvision Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Silver on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Silver on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48/42/48 48/42/48 48/42/48 48/42/48 47/42/47 47/42/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 29/61/6 29/61/62 29/61/61 29/61/60 28/61/58 28/61/57 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 20
231 CE Marking of Coated glass - EN :2004 Stopray Smart 0/20 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Smart 0/20, intended to be used in buildings and construction works, following EN :2004 NB Stopray Smart 0/20 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 9 / 28 2 / 9 / 27 2 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 20 / 1 / 0 19 / 1 / / 1 / 25 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 21
232 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopray Smart 0/20 Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Smart 0/20 Heat strengthened, intended to be used in buildings and construction works, following EN :2004 NB Stopray Smart 0/20 Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 9 / 28 2 / 9 / 27 2 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 20 / 1 / 0 19 / 1 / / 1 / 25 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 22
233 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopray Smart 0/20 Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Smart 0/20 Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 NB Stopray Smart 0/20 Thermally toughened or Heat soaked thermally AVCP Systems toughened characteristics in : 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 9 / 28 2 / 9 / 27 2 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 20 / 1 / 0 19 / 1 / / 1 / 25 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 2
234 CE Marking of Coated glass - EN :2004 Stopray Smart 51/ (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Smart 51/, intended to be used in buildings and construction works, following EN :2004 NB Stopray Smart 51/ characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 12 / 2 55 / 12 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 7 / 0 2 / 7 / 27 1 / 7 / 24 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 24
235 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopray Smart 51/ Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Smart 51/ Heat strengthened, intended to be used in buildings and construction works, following EN :2004 NB Stopray Smart 51/ Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 12 / 2 55 / 12 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 7 / 0 2 / 7 / 27 1 / 7 / 24 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 25
236 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopray Smart 51/ Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Smart 51/ Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 NB Stopray Smart 51/ Thermally toughened or Heat soaked thermally AVCP Systems toughened characteristics in : 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 12 / 2 55 / 12 / / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 7 / 0 2 / 7 / 27 1 / 7 / 24 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 26
237 CE Marking of Coated glass - EN :2004 Stopray Titanium 7T (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Titanium 7T, intended to be used in buildings and construction works, following EN :2004 NB Stopray Titanium 7T characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 27
238 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopray Titanium 7T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Titanium 7T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopray Titanium 7T Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 41 / 5 / 5 2 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 25 / 8 / 1 20 / 7 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 28
239 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopray Titanium 7T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Titanium 7T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopray Titanium 7T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 41 / 5 / 5 2 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 25 / 8 / 1 20 / 7 / 10 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 29
240 CE Marking of Coated glass - EN :2004 Stopray Vision-6T (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-6T, intended to be used in buildings and construction works, following EN :2004 NB Stopray Vision-6T characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 240
241 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopray Vision-6T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-6T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopray Vision-6T Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 9 / 1 / 29 8 / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 55 / / 56 / 7 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 241
242 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopray Vision-6T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-6T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 NB Stopray Vision-6T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) NPD NPD 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 9 / 1 / 29 8 / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 55 / / 56 / 7 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 242
243 CE Marking of Coated glass - EN :2004 Stopray Vision-50 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-50, intended to be used in buildings and construction works, following EN :2004 NB Stopray Vision-50 characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 55 / 17 / / 17 / / 17 / / 17 / 16 5 / 17 / 16 5 / 17 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 29 / 4 / 5 29 / 4 / 28 / 4 / 2 28 / 4 / / 4 / / 4 / 25 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 24
244 CE Marking of Coated glass - EN :2004 Stopray Vision-50 on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-50 on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Vision-50 on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56/17/17 56/17/17 56/17/17 56/17/17 56/17/17 56/17/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0/4/42 0/4/41 0/4/41 0/4/40 0/4/9 0/4/8 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 244
245 CE Marking of Coated glass - EN :2004 Stopray Vision-50T (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-50T, intended to be used in buildings and construction works, following EN :2004 NB Stopray Vision-50T characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 245
246 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopray Vision-50T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-50T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopray Vision-50T Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 55 / 16 / / 16 / / 16 / 15 5 / 16 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 44 / 5 1 / 44 / 1 0 / 44 / / 44 / 26 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 246
247 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopray Vision-50T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-50T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopray Vision-50T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 55 / 16 / / 16 / / 16 / 15 5 / 16 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 44 / 5 1 / 44 / 1 0 / 44 / / 44 / 26 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 247
248 CE Marking of Coated glass - EN :2004 Stopray Vision-60 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-60, intended to be used in buildings and construction works, following EN :2004 NB Stopray Vision-60 characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 67 / 12 / / 12 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 6 / 8 / 29 5 / 8 / 26 4 / 8 / 24 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 248
249 CE Marking of Coated glass - EN :2004 Stopray Vision-60T (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-60T, intended to be used in buildings and construction works, following EN :2004 NB Stopray Vision-60T characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 249
250 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopray Vision-60T Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-60T Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopray Vision-60T Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 66 / 15 / / 15 / / 15 / / 15 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 9 / 41 / 0 8 / 41 / 26 7 / 41 / 2 6 / 41 / 21 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 250
251 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopray Vision-60T Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Vision-60T Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopray Vision-60T Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 66 / 15 / / 15 / / 15 / / 15 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 9 / 41 / 0 8 / 41 / 26 7 / 41 / 2 6 / 41 / 21 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 251
252 CE Marking of Coated glass - EN :2004 Stopray Ultra-50 on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Ultra-50 on Cleavision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Ultra-50 on Clearvision characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 1C1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 54 / 7 / / 7 / / 7 / / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 24 / 47 / / 47 / 45 2 / 47 / 44 2 / 47 / 4 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 252
253 CE Marking of Coated glass - EN :2004 Stopray Ultra-60 (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Ultra-60, intended to be used in buildings and construction works, following EN :2004 NB Stopray Ultra-60 characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 1C1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 67 / 8 / 9 66 / 8 / 9 65 / 8 / 9 64 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 29 / 48 / 8 29 / 48 / 4 29 / 48 / 1 28 / 48 / 28 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 25
254 CE Marking of Coated glass - EN :2004 Stopray Aquamarine (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Aquamarine, intended to be used in buildings and construction works, following EN :2004 NB Stopray Aquamarine characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 72 / 8 / / 8 / / 8 / 9 61 / 7 / 9 56 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 9 / 0 / 11 6 / 0 / 10 / 0 / 8 28 / 0 / 7 24 / 0 / 6 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 254
255 CE Marking of Coated glass - EN :2004 Stopray Aquamarine Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Aquamarine, intended to be used in buildings and construction works, following EN :2004 NB Stopray Aquamarine characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 72 / 8 / / 8 / / 8 / 9 61 / 7 / 9 56 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 9 / 0 / 11 6 / 0 / 10 / 0 / 8 28 / 0 / 7 24 / 0 / 6 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 255
256 CE Marking of Coated glass - EN :2004 Stopray Aquamarine Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Aquamarine, intended to be used in buildings and construction works, following EN :2004 NB Stopray Aquamarine characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 72 / 8 / / 8 / / 8 / 9 61 / 7 / 9 56 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 9 / 0 / 11 6 / 0 / 10 / 0 / 8 28 / 0 / 7 24 / 0 / 6 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 256
257 CE Marking of Coated glass - EN :2004 Stopray Blue Night (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Blue Night, intended to be used in buildings and construction works, following EN :2004 NB Stopray Blue Night characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 25 / 41 / / 41 / 11 1 / 41 / 8 10 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 60 / 12 9 / 60 / 8 6 / 60 / 6 5 / 60 / 6 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 257
258 CE Marking of Coated glass - EN :2004 Stopray Blue Night Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Blue Night, intended to be used in buildings and construction works, following EN :2004 NB Stopray Blue Night characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 25 / 41 / / 41 / 11 1 / 41 / 8 10 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 60 / 12 9 / 60 / 8 6 / 60 / 6 5 / 60 / 6 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 258
259 CE Marking of Coated glass - EN :2004 Stopray Blue Night Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Blue Night, intended to be used in buildings and construction works, following EN :2004 NB Stopray Blue Night characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 25 / 41 / / 41 / 11 1 / 41 / 8 10 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 60 / 12 9 / 60 / 8 6 / 60 / 6 5 / 60 / 6 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 259
260 CE Marking of Coated glass - EN :2004 Stopray Bright Sepia (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Bright Sepia, intended to be used in buildings and construction works, following EN :2004 NB Stopray Bright Sepia characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 41 / 24 0 / 41 / / 41 / / 41 / 1 18 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 20 / 60 / 1 18 / 60 / / 60 / / 60 / / 60 / 1 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 260
261 CE Marking of Coated glass - EN :2004 Stopray Bright Sepia Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Bright Sepia, intended to be used in buildings and construction works, following EN :2004 NB Stopray Bright Sepia characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 41 / 24 0 / 41 / / 41 / / 41 / 1 18 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 20 / 60 / 1 18 / 60 / / 60 / / 60 / / 60 / 1 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 261
262 CE Marking of Coated glass - EN :2004 Stopray Bright Sepia Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Bright Sepia, intended to be used in buildings and construction works, following EN :2004 NB Stopray Bright Sepia characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 41 / 24 0 / 41 / / 41 / / 41 / 1 18 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 20 / 60 / 1 18 / 60 / / 60 / / 60 / / 60 / 1 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 262
263 CE Marking of Coated glass - EN :2004 Stopray Carat (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Carat, intended to be used in buildings and construction works, following EN :2004 NB Stopray Carat characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 58 / 9 / / 9 / / 9 / / 9 / / 9 / / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 45 / / 45 / / 45 / / 45 / 2 26 / 45 / / 45 / 20 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 26
264 CE Marking of Coated glass - EN :2004 Stopray Carat Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Carat, intended to be used in buildings and construction works, following EN :2004 NB Stopray Carat characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 58 / 9 / / 9 / / 9 / / 9 / / 9 / / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 45 / / 45 / / 45 / / 45 / 2 26 / 45 / / 45 / 20 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 264
265 CE Marking of Coated glass - EN :2004 Stopray Carat Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Carat, intended to be used in buildings and construction works, following EN :2004 NB Stopray Carat characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 58 / 9 / / 9 / / 9 / / 9 / / 9 / / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 45 / / 45 / / 45 / / 45 / 2 26 / 45 / / 45 / 20 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 265
266 CE Marking of Coated glass - EN :2004 Stopray Chroma (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Chroma, intended to be used in buildings and construction works, following EN :2004 NB Stopray Chroma characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 51 / 7 / 7 45 / 6 / 6 40 / 6 / 6 1 / 6 / 5 24 / 6 / 5 19 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 0 / 16 4 / 0 / 14 0 / 0 / / 29 / 9 19 / 29 / 8 15 / 29 / 7 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 266
267 CE Marking of Coated glass - EN :2004 Stopray Chroma Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Chroma, intended to be used in buildings and construction works, following EN :2004 NB Stopray Chroma characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 51 / 7 / 7 45 / 6 / 6 40 / 6 / 6 1 / 6 / 5 24 / 6 / 5 19 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 0 / 16 4 / 0 / 14 0 / 0 / / 29 / 9 19 / 29 / 8 15 / 29 / 7 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 267
268 CE Marking of Coated glass - EN :2004 Stopray Chroma Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Chroma, intended to be used in buildings and construction works, following EN :2004 NB Stopray Chroma characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 51 / 7 / 7 45 / 6 / 6 40 / 6 / 6 1 / 6 / 5 24 / 6 / 5 19 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 0 / 16 4 / 0 / 14 0 / 0 / / 29 / 9 19 / 29 / 8 15 / 29 / 7 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 268
269 CE Marking of Coated glass - EN :2004 Stopray Cristal (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Cristal, intended to be used in buildings and construction works, following EN :2004 NB Stopray Cristal characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,06 0,06 0,06 0,06 0,06 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 69 / 6 / / 6 / / 6 / / 6 / / 6 / / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 45 / 1 / / 1 / / 1 / / 1 / / 1 / 2 40 / 0 / 21 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 269
270 CE Marking of Coated glass - EN :2004 Stopray Cristal Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Cristal, intended to be used in buildings and construction works, following EN :2004 NB Stopray Cristal characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,06 0,06 0,06 0,06 0,06 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 69 / 6 / / 6 / / 6 / / 6 / / 6 / / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 45 / 1 / / 1 / / 1 / / 1 / / 1 / 2 40 / 0 / 21 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 270
271 CE Marking of Coated glass - EN :2004 Stopray Cristal Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Cristal, intended to be used in buildings and construction works, following EN :2004 NB Stopray Cristal characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,06 0,06 0,06 0,06 0,06 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 69 / 6 / / 6 / / 6 / / 6 / / 6 / / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 45 / 1 / / 1 / / 1 / / 1 / / 1 / 2 40 / 0 / 21 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 271
272 CE Marking of Coated glass - EN :2004 Stopray Deep Blue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Deep Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Deep Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 6 / 12 / 6 26 / 11 / 5 19 / 11 / 5 14 / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 17 / 41 / 7 12 / 41 / 5 9 / 41 / 5 7 / 41 / 5 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 272
273 CE Marking of Coated glass - EN :2004 Stopray Deep Blue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Deep Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Deep Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 6 / 12 / 6 26 / 11 / 5 19 / 11 / 5 14 / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 17 / 41 / 7 12 / 41 / 5 9 / 41 / 5 7 / 41 / 5 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 27
274 CE Marking of Coated glass - EN :2004 Stopray Deep Blue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Deep Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Deep Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 6 / 12 / 6 26 / 11 / 5 19 / 11 / 5 14 / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 17 / 41 / 7 12 / 41 / 5 9 / 41 / 5 7 / 41 / 5 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 274
275 CE Marking of Coated glass - EN :2004 Stopray Elite (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Elite, intended to be used in buildings and construction works, following EN :2004 NB Stopray Elite characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 75 / 9 / 9 75 / 9 / 9 75 / 9 / 9 74 / 9 / 9 7 / 9 / 9 72 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 42 / 8 / 0 42 / 8 / / 8 / / 8 / / 8 / 2 9 / 8 / 22 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 275
276 CE Marking of Coated glass - EN :2004 Stopray Elite Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Elite, intended to be used in buildings and construction works, following EN :2004 NB Stopray Elite characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 75 / 9 / 9 75 / 9 / 9 75 / 9 / 9 74 / 9 / 9 7 / 9 / 9 72 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 42 / 8 / 0 42 / 8 / / 8 / / 8 / / 8 / 2 9 / 8 / 22 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 276
277 CE Marking of Coated glass - EN :2004 Stopray Elite Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Elite, intended to be used in buildings and construction works, following EN :2004 NB Stopray Elite characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 75 / 9 / 9 75 / 9 / 9 75 / 9 / 9 74 / 9 / 9 7 / 9 / 9 72 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 42 / 8 / 0 42 / 8 / / 8 / / 8 / / 8 / 2 9 / 8 / 22 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 277
278 CE Marking of Coated glass - EN :2004 Stopray Elite on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Elite on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Elite on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 77 / 9 / / 9 / / 9 / / 9 / / 9 / / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 8 / 5 44 / 8 / 5 44 / 8 / 5 44 / 8 / 4 44 / 8 / 44 / 8 / NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 278
279 CE Marking of Coated glass - EN :2004 Stopray Elite on Clearvision Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Elite on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Elite on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 77 / 9 / / 9 / / 9 / / 9 / / 9 / / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 8 / 5 44 / 8 / 5 44 / 8 / 5 44 / 8 / 4 44 / 8 / 44 / 8 / NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 279
280 CE Marking of Coated glass - EN :2004 Stopray Elite on Clearvision Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Elite on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Elite on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 77 / 9 / / 9 / / 9 / / 9 / / 9 / / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 8 / 5 44 / 8 / 5 44 / 8 / 5 44 / 8 / 4 44 / 8 / 44 / 8 / NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 280
281 CE Marking of Coated glass - EN :2004 Stopray Emeralda (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Emeralda, intended to be used in buildings and construction works, following EN :2004 NB Stopray Emeralda characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 42 / 6 41 / 42 / 4 40 / 41 / 2 7 / 41 / 28 4 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 22 / 61 / / 61 / 2 19 / 60 / / 60 / / 60 / 14 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 281
282 CE Marking of Coated glass - EN :2004 Stopray Emeralda Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Emeralda, intended to be used in buildings and construction works, following EN :2004 NB Stopray Emeralda characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 42 / 6 41 / 42 / 4 40 / 41 / 2 7 / 41 / 28 4 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 22 / 61 / / 61 / 2 19 / 60 / / 60 / / 60 / 14 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 282
283 CE Marking of Coated glass - EN :2004 Stopray Emeralda Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Emeralda, intended to be used in buildings and construction works, following EN :2004 NB Stopray Emeralda characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 42 / 6 41 / 42 / 4 40 / 41 / 2 7 / 41 / 28 4 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 22 / 61 / / 61 / 2 19 / 60 / / 60 / / 60 / 14 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 28
284 CE Marking of Coated glass - EN :2004 Stopray Galaxy (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Galaxy, intended to be used in buildings and construction works, following EN :2004 NB Stopray Galaxy characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 45 / 14 / / 14 / / 14 / / 14 / / 14 / 14 4 / 14 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / 2 20 / 4 / 1 20 / 4 / / 4 / / 4 / / 4 / 2 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 284
285 CE Marking of Coated glass - EN :2004 Stopray Galaxy Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Galaxy, intended to be used in buildings and construction works, following EN :2004 NB Stopray Galaxy characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 45 / 14 / / 14 / / 14 / / 14 / / 14 / 14 4 / 14 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / 2 20 / 4 / 1 20 / 4 / / 4 / / 4 / / 4 / 2 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 285
286 CE Marking of Coated glass - EN :2004 Stopray Galaxy Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Galaxy, intended to be used in buildings and construction works, following EN :2004 NB Stopray Galaxy characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 45 / 14 / / 14 / / 14 / / 14 / / 14 / 14 4 / 14 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / 2 20 / 4 / 1 20 / 4 / / 4 / / 4 / / 4 / 2 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 286
287 CE Marking of Coated glass - EN :2004 Stopray Galaxy on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Galaxy on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Galaxy on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 45 / 14 / / 14 / / 14 / / 14 / / 14 / / 14 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / 9 21 / 4 / 8 21 / 4 / 8 21 / 4 / 7 21 / 4 / 6 21 / 4 / 5 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 287
288 CE Marking of Coated glass - EN :2004 Stopray Galaxy on Clearvision Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Galaxy on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Galaxy on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 45 / 14 / / 14 / / 14 / / 14 / / 14 / / 14 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / 9 21 / 4 / 8 21 / 4 / 8 21 / 4 / 7 21 / 4 / 6 21 / 4 / 5 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 288
289 CE Marking of Coated glass - EN :2004 Stopray Galaxy on Clearvision Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Galaxy on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Galaxy on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 45 / 14 / / 14 / / 14 / / 14 / / 14 / / 14 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / 9 21 / 4 / 8 21 / 4 / 8 21 / 4 / 7 21 / 4 / 6 21 / 4 / 5 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 289
290 CE Marking of Coated glass - EN :2004 Stopray Granit Grey (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Granit Grey, intended to be used in buildings and construction works, following EN :2004 NB Stopray Granit Grey characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 0 / 41 / / 41 / 17 2 / 41 / / 41 / / 41 / 8 11 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 19 / 60 / / 60 / / 60 / / 60 / / 60 / 11 8 / 60 / 9 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 290
291 CE Marking of Coated glass - EN :2004 Stopray Granit Grey Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Granit Grey, intended to be used in buildings and construction works, following EN :2004 NB Stopray Granit Grey characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 0 / 41 / / 41 / 17 2 / 41 / / 41 / / 41 / 8 11 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 19 / 60 / / 60 / / 60 / / 60 / / 60 / 11 8 / 60 / 9 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 291
292 CE Marking of Coated glass - EN :2004 Stopray Granit Grey Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Granit Grey, intended to be used in buildings and construction works, following EN :2004 NB Stopray Granit Grey characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 0 / 41 / / 41 / 17 2 / 41 / / 41 / / 41 / 8 11 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 19 / 60 / / 60 / / 60 / / 60 / / 60 / 11 8 / 60 / 9 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 292
293 CE Marking of Coated glass - EN :2004 Stopray Marine Blue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Marine Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Marine Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 6 / 7 1 / 6 / 6 2 / 6 / 5 17 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2 / 29 / 7 16 / 29 / 5 11 / 29 / 5 8 / 29 / 5 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 29
294 CE Marking of Coated glass - EN :2004 Stopray Marine Blue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Marine Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Marine Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 6 / 7 1 / 6 / 6 2 / 6 / 5 17 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2 / 29 / 7 16 / 29 / 5 11 / 29 / 5 8 / 29 / 5 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 294
295 CE Marking of Coated glass - EN :2004 Stopray Marine Blue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Marine Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Marine Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 6 / 7 1 / 6 / 6 2 / 6 / 5 17 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2 / 29 / 7 16 / 29 / 5 11 / 29 / 5 8 / 29 / 5 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 295
296 CE Marking of Coated glass - EN :2004 Stopray Metal Blue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Metal Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Metal Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 72 / 8 / / 8 / 9 62 / 7 / 9 58 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 42 / 0 / 1 6 / 0 / 10 2 / 0 / 8 28 / 0 / 7 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 296
297 CE Marking of Coated glass - EN :2004 Stopray Metal Blue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Metal Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Metal Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 72 / 8 / / 8 / 9 62 / 7 / 9 58 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 42 / 0 / 1 6 / 0 / 10 2 / 0 / 8 28 / 0 / 7 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 297
298 CE Marking of Coated glass - EN :2004 Stopray Metal Blue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Metal Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Metal Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 72 / 8 / / 8 / 9 62 / 7 / 9 58 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 42 / 0 / 1 6 / 0 / 10 2 / 0 / 8 28 / 0 / 7 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 298
299 CE Marking of Coated glass - EN :2004 Stopray Neutral (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Neutral, intended to be used in buildings and construction works, following EN :2004 NB Stopray Neutral characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,10 0,10 0,10 0,10 0,10 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 24 / / 24 / / 24 / / 24 / / 24 / 9 5 / 24 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 1 / 18 4 / 1 / / 1 / / 1 / 15 9 / 1 / 14 8 / 1 / 1 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 299
300 CE Marking of Coated glass - EN :2004 Stopray Neutral Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Neutral, intended to be used in buildings and construction works, following EN :2004 NB Stopray Neutral characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,10 0,10 0,10 0,10 0,10 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 24 / / 24 / / 24 / / 24 / / 24 / 9 5 / 24 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 1 / 18 4 / 1 / / 1 / / 1 / 15 9 / 1 / 14 8 / 1 / 1 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 00
301 CE Marking of Coated glass - EN :2004 Stopray Neutral Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Neutral, intended to be used in buildings and construction works, following EN :2004 NB Stopray Neutral characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,10 0,10 0,10 0,10 0,10 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 24 / / 24 / / 24 / / 24 / / 24 / 9 5 / 24 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 1 / 18 4 / 1 / / 1 / / 1 / 15 9 / 1 / 14 8 / 1 / 1 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 01
302 CE Marking of Coated glass - EN :2004 Stopray Oasis (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Oasis, intended to be used in buildings and construction works, following EN :2004 NB Stopray Oasis characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 66 / 9 / 8 64 / 9 / 8 61 / 8 / 8 57 / 8 / 7 5 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 7 / 11 0 / 7 / 9 28 / 7 / 8 25 / 7 / 6 22 / 7 / 6 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 02
303 CE Marking of Coated glass - EN :2004 Stopray Oasis Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Oasis, intended to be used in buildings and construction works, following EN :2004 NB Stopray Oasis characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 66 / 9 / 8 64 / 9 / 8 61 / 8 / 8 57 / 8 / 7 5 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 7 / 11 0 / 7 / 9 28 / 7 / 8 25 / 7 / 6 22 / 7 / 6 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 0
304 CE Marking of Coated glass - EN :2004 Stopray Oasis Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Oasis, intended to be used in buildings and construction works, following EN :2004 NB Stopray Oasis characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 66 / 9 / 8 64 / 9 / 8 61 / 8 / 8 57 / 8 / 7 5 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 7 / 11 0 / 7 / 9 28 / 7 / 8 25 / 7 / 6 22 / 7 / 6 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 04
305 CE Marking of Coated glass - EN :2004 Stopray Quartz (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Quartz, intended to be used in buildings and construction works, following EN :2004 NB Stopray Quartz characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48 / 6 / 6 42 / 6 / 5 7 / 6 / 5 28 / 6 / 5 22 / 6 / 5 17 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 7 / / 7 / / 7 / / 7 / 7 1 / 7 / 6 10 / 7 / 6 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 05
306 CE Marking of Coated glass - EN :2004 Stopray Quartz Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Quartz, intended to be used in buildings and construction works, following EN :2004 NB Stopray Quartz characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48 / 6 / 6 42 / 6 / 5 7 / 6 / 5 28 / 6 / 5 22 / 6 / 5 17 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 7 / / 7 / / 7 / / 7 / 7 1 / 7 / 6 10 / 7 / 6 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 06
307 CE Marking of Coated glass - EN :2004 Stopray Quartz Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Quartz, intended to be used in buildings and construction works, following EN :2004 NB Stopray Quartz characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) 1C 1C 1C2 1C2 1C1 1C1 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 48 / 6 / 6 42 / 6 / 5 7 / 6 / 5 28 / 6 / 5 22 / 6 / 5 17 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 7 / / 7 / / 7 / / 7 / 7 1 / 7 / 6 10 / 7 / 6 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 07
308 CE Marking of Coated glass - EN :2004 Stopray Reflex Blue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Reflex Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Reflex Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 42 / 6 40 / 41 / 2 7 / 41 / 28 4 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 22 / 61 / / 61 / / 60 / / 60 / 15 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 08
309 CE Marking of Coated glass - EN :2004 Stopray Reflex Blue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Reflex Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Reflex Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 42 / 6 40 / 41 / 2 7 / 41 / 28 4 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 22 / 61 / / 61 / / 60 / / 60 / 15 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 09
310 CE Marking of Coated glass - EN :2004 Stopray Reflex Blue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Reflex Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopray Reflex Blue characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 42 / 6 40 / 41 / 2 7 / 41 / 28 4 / 41 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 22 / 61 / / 61 / / 60 / / 60 / 15 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 10
311 CE Marking of Coated glass - EN :2004 Stopray Safir (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Safir, intended to be used in buildings and construction works, following EN :2004 NB Stopray Safir characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 1 / / 1 / / 1 / / 1 / / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 6 / 42 / 6 / 42 / 2 6 / 42 / 0 5 / 42 / 28 4 / 42 / 25 / 42 / 24 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 11
312 CE Marking of Coated glass - EN :2004 Stopray Safir Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Safir, intended to be used in buildings and construction works, following EN :2004 NB Stopray Safir characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 1 / / 1 / / 1 / / 1 / / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 6 / 42 / 6 / 42 / 2 6 / 42 / 0 5 / 42 / 28 4 / 42 / 25 / 42 / 24 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 12
313 CE Marking of Coated glass - EN :2004 Stopray Safir Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Safir, intended to be used in buildings and construction works, following EN :2004 NB Stopray Safir characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 68 / 1 / / 1 / / 1 / / 1 / / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 6 / 42 / 6 / 42 / 2 6 / 42 / 0 5 / 42 / 28 4 / 42 / 25 / 42 / 24 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 1
314 CE Marking of Coated glass - EN :2004 Stopray Safir on Clearvision (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Safir on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Safir on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 70 / 1 / / 1 / / 1 / / 1 / / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 42 / 8 8 / 42 / 8 8 / 42 / 7 7 / 42 / 7 7 / 42 / 6 7 / 42 / 5 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 14
315 CE Marking of Coated glass - EN :2004 Stopray Safir on Clearvision Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Safir on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Safir on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 70 / 1 / / 1 / / 1 / / 1 / / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 42 / 8 8 / 42 / 8 8 / 42 / 7 7 / 42 / 7 7 / 42 / 6 7 / 42 / 5 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 15
316 CE Marking of Coated glass - EN :2004 Stopray Safir on Clearvision Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Safir on Clearvision, intended to be used in buildings and construction works, following EN :2004 NB Stopray Safir on Clearvision characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 12 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) 5 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 70 / 1 / / 1 / / 1 / / 1 / / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 42 / 8 8 / 42 / 8 8 / 42 / 7 7 / 42 / 7 7 / 42 / 6 7 / 42 / 5 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 16
317 CE Marking of Coated glass - EN :2004 Stopray Selva (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Selva, intended to be used in buildings and construction works, following EN :2004 NB Stopray Selva characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,06 0,06 0,06 0,06 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 60 / 6 / / 6 / / 6 / / 6 / / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2 / 0 / / 0 / / 0 / 9 2 / 0 / 8 21 / 0 / 7 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 17
318 CE Marking of Coated glass - EN :2004 Stopray Selva Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Selva, intended to be used in buildings and construction works, following EN :2004 NB Stopray Selva characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,06 0,06 0,06 0,06 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 60 / 6 / / 6 / / 6 / / 6 / / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2 / 0 / / 0 / / 0 / 9 2 / 0 / 8 21 / 0 / 7 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 18
319 CE Marking of Coated glass - EN :2004 Stopray Selva Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Selva, intended to be used in buildings and construction works, following EN :2004 NB Stopray Selva characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,06 0,06 0,06 0,06 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 60 / 6 / / 6 / / 6 / / 6 / / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 2 / 0 / / 0 / / 0 / 9 2 / 0 / 8 21 / 0 / 7 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 19
320 CE Marking of Coated glass - EN :2004 Stopray Sienna (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Sienna, intended to be used in buildings and construction works, following EN :2004 NB Stopray Sienna characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 52 / 8 / 7 47 / 8 / 6 42 / 8 / 6 4 / 7 / 5 28 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 7 / / 7 / / 7 / / 7 / / 7 / 9 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 20
321 CE Marking of Coated glass - EN :2004 Stopray Sienna Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Sienna, intended to be used in buildings and construction works, following EN :2004 NB Stopray Sienna characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 52 / 8 / 7 47 / 8 / 6 42 / 8 / 6 4 / 7 / 5 28 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 7 / / 7 / / 7 / / 7 / / 7 / 9 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 21
322 CE Marking of Coated glass - EN :2004 Stopray Sienna Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Sienna, intended to be used in buildings and construction works, following EN :2004 NB Stopray Sienna characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 52 / 8 / 7 47 / 8 / 6 42 / 8 / 6 4 / 7 / 5 28 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 7 / / 7 / / 7 / / 7 / / 7 / 9 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASSa PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 22
323 CE Marking of Coated glass - EN :2004 Stopray Topaz (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Topaz, intended to be used in buildings and construction works, following EN :2004 NB Stopray topaz characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 7 / 8 51 / 7 / 7 45 / 7 / 7 7 / 6 / 6 0 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 0 / 18 6 / 0 / 15 2 / 0 / 1 27 / 0 / / 0 / 9 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 2
324 CE Marking of Coated glass - EN :2004 Stopray Topaz Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Topaz, intended to be used in buildings and construction works, following EN :2004 NB Stopray topaz characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 7 / 8 51 / 7 / 7 45 / 7 / 7 7 / 6 / 6 0 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 0 / 18 6 / 0 / 15 2 / 0 / 1 27 / 0 / / 0 / 9 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 24
325 CE Marking of Coated glass - EN :2004 Stopray Topaz Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Topaz, intended to be used in buildings and construction works, following EN :2004 NB Stopray topaz characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 7 / 8 51 / 7 / 7 45 / 7 / 7 7 / 6 / 6 0 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 0 / 18 6 / 0 / 15 2 / 0 / 1 27 / 0 / / 0 / 9 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 25
326 CE Marking of Coated glass - EN :2004 Stopray Ultramarine (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Ultramarine, intended to be used in buildings and construction works, following EN :2004 NB Stopray Ultramarine characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 61 / 12 / / 12 / 9 5 / 12 / 9 49 / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 42 / / 42 / / 41 / 8 22 / 41 / 7 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 26
327 CE Marking of Coated glass - EN :2004 Stopray Ultramarine Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Ultramarine, intended to be used in buildings and construction works, following EN :2004 NB Stopray Ultramarine characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 61 / 12 / / 12 / 9 5 / 12 / 9 49 / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 42 / / 42 / / 41 / 8 22 / 41 / 7 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 27
328 CE Marking of Coated glass - EN :2004 Stopray Ultramarine Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopray Ultramarine, intended to be used in buildings and construction works, following EN :2004 NB Stopray Ultramarine characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 61 / 12 / / 12 / 9 5 / 12 / 9 49 / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 42 / / 42 / / 41 / 8 22 / 41 / 7 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 28
329 Stopsol 29
330 CE Marking of Coated glass - EN :2004 Stopsol Classic Clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Clear, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Classic Clear characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 4 / 27 8 / 4 / 27 8 / 4 / 27 7 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 48 / 29 / / 29 / / 29 / / 28 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 0
331 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Classic Clear Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Clear Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Classic Clear Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 4 / 27 8 / 4 / 27 8 / 4 / 27 7 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 48 / 29 / / 29 / / 29 / / 28 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 1
332 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Classic Clear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Clear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Classic Clear Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 4 / 27 8 / 4 / 27 8 / 4 / 27 7 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 48 / 29 / / 29 / / 29 / / 28 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 2
333 CE Marking of Coated glass - EN :2004 Stopsol Classic Bronze (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Bronze, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Classic Bronze characteristics in : AVCP Systems 4 mm 5 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) U-value (EN 67) 5,8 5,8 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 26 / 4 / / 4 / 1 22 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 5 / 28 / 14 2 / 28 / / 28 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building
334 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Classic Bronze Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Bronze Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Classic Bronze Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) U-value (EN 67) 5,8 5,8 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 26 / 4 / / 4 / 1 22 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 5 / 28 / 14 2 / 28 / / 28 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 4
335 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Classic Bronze Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Bronze Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Classic Bronze Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) 1C 1C 1C2 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) U-value (EN 67) 5,8 5,8 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 26 / 4 / / 4 / 1 22 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 5 / 28 / 14 2 / 28 / / 28 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 5
336 CE Marking of Coated glass - EN :2004 Stopsol Classic Dark Blue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Dark Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Classic Dark Blue characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 24 / 4 / / 28 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / / 28 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 6
337 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Classic Dark Blue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Dark Blue Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Classic Dark Blue Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 24 / 4 / / 28 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / / 28 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 7
338 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Classic Dark Blue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Dark Blue Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Classic Dark Blue Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 24 / 4 / / 28 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 21 / 4 / / 28 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 8
339 CE Marking of Coated glass - EN :2004 Stopsol Classic Green (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Green, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Classic Green characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 4 / 22 2 / 4 / 21 1 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 28 / 1 25 / 28 / / 28 / / 28 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 9
340 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Classic Green Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Green Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Classic Green Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 4 / 22 2 / 4 / 21 1 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 28 / 1 25 / 28 / / 28 / / 28 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 40
341 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Classic Green Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Green Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Classic Green Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,8 5,7 5,7 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 4 / 22 2 / 4 / 21 1 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 28 / 1 25 / 28 / / 28 / / 28 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 41
342 CE Marking of Coated glass - EN :2004 Stopsol Classic Grey (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Grey, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Classic Grey characteristics in : AVCP Systems 4 mm 5 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) U-value (EN 67) 5,8 5,8 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 24 / 4 / 1 21 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 28 / 1 0 / 28 / / 28 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 42
343 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Classic Grey Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Grey Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Classic Grey Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) U-value (EN 67) 5,8 5,8 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 24 / 4 / 1 21 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 28 / 1 0 / 28 / / 28 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 4
344 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Classic Grey Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Classic Grey Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Classic Grey Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) U-value (EN 67) 5,8 5,8 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 24 / 4 / 1 21 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 28 / 1 0 / 28 / / 28 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 44
345 CE Marking of Coated glass - EN :2004 Stopsol Phoenix Clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Clear, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Phoenix Clear characteristics in : AVCP Systems 4 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 1 (-2;-) U-value (EN 67) ,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 67 / 2 / 1 67 / 1 / 0 66 / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 69 / 25 / 2 67 / 25 / / 25 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 45
346 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Phoenix Clear Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Clear Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Phoenix Clear Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 1 (-2;-) U-value (EN 67) ,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 67 / 2 / 1 67 / 1 / 0 66 / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 69 / 25 / 2 67 / 25 / / 25 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 46
347 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Phoenix Clear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Clear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004/ NB Stopsol Phoenix Clear Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 1 (-2;-) U-value (EN 67) ,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 67 / 2 / 1 67 / 1 / 0 66 / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 69 / 25 / 2 67 / 25 / / 25 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 47
348 CE Marking of Coated glass - EN :2004 Stopsol Phoenix Green (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Green, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Phoenix Green characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 1 (-2;-) U-value (EN 67) 5,7 5,6 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 54 / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 2 / / 2 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 48
349 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Phoenix Green Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Green Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Phoenix Green Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) 5,7 5,6 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 54 / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 2 / / 2 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 49
350 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Phoenix Green Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Green Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Phoenix Green Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) 5,7 5,6 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 54 / 1 / / 1 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 2 / / 2 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 50
351 CE Marking of Coated glass - EN :2004 Stopsol Phoenix Grey (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Grey, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Phoenix Grey characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 1 (-2;-) U-value (EN 67) 5,7 5,6 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 0 / / 0 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 2 / 10 0 / 2 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 51
352 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Phoenix Grey Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Grey Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Phoenix Grey Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) 5,7 5,6 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 0 / / 0 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 2 / 10 0 / 2 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 52
353 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Phoenix Grey Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Phoenix Grey Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Phoenix Grey Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) U-value (EN 67) 5,7 5,6 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v / 0 / / 0 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 2 / 10 0 / 2 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 5
354 CE Marking of Coated glass - EN :2004 Stopsol SilverLight PrivaBlue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol SilverLight PrivaBlue, intended to be used in buildings and construction works, following EN :2004 NB Stopsol SilverLight PrivaBlue characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 27 / 24 / 8 20 / 24 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 16 / 20 / 6 11 / 20 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 54
355 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol SilverLight PrivaBlue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol SilverLight PrivaBlue Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 Stopsol SilverLight PrivaBlue Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 27 / 24 / 8 20 / 24 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 16 / 20 / 6 11 / 20 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 55
356 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol SilverLight PrivaBlue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol SilverLight PrivaBlue Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol SilverLight PrivaBlue Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 27 / 24 / 8 20 / 24 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 16 / 20 / 6 11 / 20 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 56
357 CE Marking of Coated glass - EN :2004 Stopsol Supersilver Clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Clear, intended to be used in buildings and construction works, following EN :2004 Stopsol Supersilver Clear characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 64 / 5 / 5 64 / 5 / 4 6 / 5 / 4 62 / 5 / 4 62 / 5 / 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 66 / 28 / / 28 / / 27 / / 27 / 2 59 / 27 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 57
358 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Supersilver Clear Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Clear Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Supersilver Clear Heat strengthened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 64 / 5 / 5 64 / 5 / 4 6 / 5 / 4 62 / 5 / 4 62 / 5 / 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 66 / 28 / / 28 / / 27 / / 27 / 2 59 / 27 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 58
359 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Supersilver Clear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Clear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Supersilver Clear Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 5 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 5,8 5,8 5,7 5,7 5,6 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 64 / 5 / 5 64 / 5 / 4 6 / 5 / 4 62 / 5 / 4 62 / 5 / 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 66 / 28 / / 28 / / 27 / / 27 / 2 59 / 27 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 59
360 CE Marking of Coated glass - EN :2004 Stopsol Supersilver Dark Blue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Dark Blue, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Supersilver Dark Blue characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 41 / 4 / 17 5 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 26 / / 26 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 60
361 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Supersilver Dark Blue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Dark Blue Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Supersilver Dark Blue Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 41 / 4 / 17 5 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 26 / / 26 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 61
362 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Supersilver Dark Blue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Dark Blue Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Supersilver Dark Blue Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 41 / 4 / 17 5 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 26 / / 26 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 62
363 CE Marking of Coated glass - EN :2004 Stopsol Supersilver Green (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Green, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Supersilver Green characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 52 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 26 / / 26 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 6
364 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Supersilver Green Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Green Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Supersilver Green Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 52 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 26 / / 26 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 64
365 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Supersilver Green Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Green Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Supersilver Green Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,7 5,7 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 52 / 4 / / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e / 26 / / 26 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 65
366 CE Marking of Coated glass - EN :2004 Stopsol Supersilver Grey (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Grey, intended to be used in buildings and construction works, following EN :2004 NB Stopsol Supersilver Grey characteristics in : AVCP Systems 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,7 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 4 / 1 29 / 4 / 11 2 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 27 / 11 4 / 27 / / 26 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 66
367 CE Marking of Heat strengthened glass - EN 186-2:2004 Stopsol Supersilver Grey Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Grey Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Stopsol Supersilver Grey Heat strengthened characteristics in : AVCP Systems 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,7 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 4 / 1 29 / 4 / 11 2 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 27 / 11 4 / 27 / / 26 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 67
368 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Stopsol Supersilver Grey Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stopsol Supersilver Grey Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Stopsol Supersilver Grey Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 5 mm 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-1;-2) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 5,8 5,7 5,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 4 / 1 29 / 4 / 11 2 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 8 / 27 / 11 4 / 27 / / 26 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 68
369 Stratobel 69
370 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel clear (22.x,.x) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD P1A-P2A PA-P4A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD 2 (-1;-) (-1;-4) NPD U-value (EN 67) 5,7 5,7 5,7 5,6 5,5 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / 8 89 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 79 / 7 / 7 77 / 7 / 7 76 / 7 / 7 74 / 7 / 7 72 / 7 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 70
371 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel clear (44.x, 55.x) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A PA-P4A P5A NPD P1A-P2A PA-P4A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) 5 (-1;-) NPD 5 (-1;-) 5 (-1;-) NPD 6 (-1;-4) U-value (EN 67) 5,6 5,6 5,5 5, 5,6 5,5 5,4 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 8 / 8 88 / 8 / 8 88 / 8 / 8 88 / 8 / 8 87 / 8 / 8 87 / 8 / 8 87 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 7 / 7 72 / 7 / 7 70 / 7 / 7 69 / 7 / 7 70 / 7 / 7 69 / 7 / 7 67 / 7 / Durability PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 71
372 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel clear (66.x) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A PA-P4A P5A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD 6 (-1;-) 7 (-1;-4) NPD U-value (EN 67) 5,5 5,4 5, 5,2 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 8 /8 86 / 8 / 8 86 / 8 / 8 86 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 68 / 7 / 7 66 / 7 / 7 65 / 6 / 6 64 / 6 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 72
373 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel clear (88.x, x) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A PA-P4A P1A-P2A PA-P4A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD 9 (-1;-) NPD NPD NPD U-value (EN 67) 5, 5, 5,2 5,2 5,1 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 8 / 8 84 / 8 / 8 84 / 8 / 8 82 / 7 / 7 82 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 6 / 6 / 6 62 / 6 / 6 60 / 6 / 6 58 / 6 / 6 56 / 6 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 7
374 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Linea Azzurra (88.x, x) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Linea Azzurra, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Linea Azzurra characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) P1A-P2A PA-P4A P1A-P2A PA-P4A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 9 (-1;-) NPD NPD NPD U-value (EN 67) 5, 5,2 5,2 5,1 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 7 / 7 82 / 7 / 7 80 / 7 / 7 80 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 55 / 6 / 6 5 / 6 / 6 50 / 6 / 6 49 / 6 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 74
375 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel iplus Energy N Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel iplus Energy N, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel iplus Energy N characteristics in : AVCP Systems Energy N Energy N Energy N Energy N Energy N Energy N 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-) (-1;-4) 4 (-1;-2) 5 (-1;-) NPD 6 (-1;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 80 / 7 / 7 80 / 7 / 7 79 / 7 / 7 79 / 7 / 7 77 / 7 / 6 77 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 41 / / 41 / 25 9 / 41 / 24 9 / 41 / 2 8 / 41 / 20 7 / 41 / 19 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 75
376 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel iplus G Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel iplus G, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel iplus G characteristics in : AVCP Systems.1 G.2 G 44.1 G 44.2 G 66.1 G 66.2 G 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-) (-1;-4) 4 (-1;-2) 5 (-1;-) NPD 6 (-1;-) U-value (EN 67),6,6,6,6,5,5 0,14 0,14 0,14 0,14 0,14 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 11 / / 11 / / 11 / / 11 / / 10 / / 10 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 66 / 11 / 9 65 / 11 / 9 64 / 11 / 9 6 / 11 / 8 60 / 10 / 8 59 / 10 / Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 76
377 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel iplus I-Top Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel iplus I-Top, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel iplus I-Top characteristics in : AVCP Systems 22.1 I-Top 22.2 I-Top.1 I-Top.2 I-Top 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD 2 (-1;-) (-1;-4) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 6 / 7 87 / 6 / 7 86 / 6 / 7 86 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 57 / 29 / / 29 / / 28 / / 28 / 18 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 77
378 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel iplus I-Top Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel iplus I-Top, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel iplus I-Top characteristics in : AVCP Systems 44.1 I-Top 44.2 I-Top 55.1 I-Top 55.2 I-Top 66.2 I-Top 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) 5 (-1;-) 5 (-1;-) NPD 6 (-1;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 85 / 5 / 7 85 / 5 / 7 84 / 5 / 7 84 / 5 / 7 8 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 52 / 28 / / 28 / / 28 / / 28 / / 28 / 1 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 78
379 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel iplus Light Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel iplus Light, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel iplus Light characteristics in : AVCP Systems 22.1 Light 22.2 Light.1 Light 44.1 Light 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD NPD 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD 2 (-1;-) 4 (-1;-2) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 71/19/21 71/19/21 71/19/21 71/19/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 41/4/4 41/4/ 41/4/29 40/4/26 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 79
380 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel iplus Top 1.0 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel iplus Top 1.0, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel iplus Top 1.0 characteristics in : AVCP Systems 22.1 Top Top Top Top Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD 2 (-1;-) (-1;-4) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 77 / 15 / / 15 / / 15 / / 15 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 45 / 42 / 45 / 42 / 2 45 / 42 / 0 44 / 42 / 29 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 80
381 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel iplus Top 1.0 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel iplus Top 1.0, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel iplus Top 1.0 characteristics in : AVCP Systems 44.1 Top Top Top Top Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) 5 (-1;-) NPD 6 (-1;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 75 / 15 / / 15 / / 14 / / 14 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 42 / 28 4 / 42 / / 42 / / 42 / 2 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 81
382 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Low-e Top N Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Low-e Top N, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Low-e Top N characteristics in : AVCP Systems.1 Top N.2 Top N 44.1 Top N 44.2 Top N 66.1 Top N 66.2 Top N 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-) (-1;-4) 4 (-1;-2) 5 (-1;-) NPD 6 (-1;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 6 / 8 86 / 6 / 8 85 / 6 / 8 85 / 6 / 8 84 / 6 / 8 8 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 60 / 25 / / 25 / / 25 / / 25 / /24 / / 24 / 14 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 82
383 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Low-e Top N+ Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Low-e Top N+, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Low-e Top N+ characteristics in : AVCP Systems 22.1 Top N Top N+.1 Top N+.2 Top N+ 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD 2 (-1;-) (-1;-4) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87/6/8 87/6/8 86/6/7 86/6/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 57/29/22 56/29/21 55/29/20 54/29/19 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 8
384 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Low-e Top N+ Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Low-e Top N+, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Low-e Top N+ characteristics in : AVCP Systems 44.1 Top N Top N Top N Top N+ 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) 5 (-1;-) NPD 6 (-1;-) U-value (EN 67) NPD NPD NPD NPD 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 85/6/7 85/6/7 8/6/7 8/6/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 5/29/18 5/29/18 50/29/16 50/29/15 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 84
385 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Low-e Tri Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Low-e Tri, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Low-e Tri characteristics in : AVCP Systems 22.1 Tri 22.2 Tri.1 Tri.2 Tri 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD 2 (-1;-) (-1;-4) U-value (EN 67) NPD NPD NPD NPD 0,07 0,07 0,07 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88/7/8 88/7/8 87/7/8 87/7/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 68/17/1 68/17/12 66/17/12 65/17/11 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 85
386 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Low-e Tri Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Low-e Tri, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Low-e Tri characteristics in : AVCP Systems 44.1 Tri 44.2 Tri 55.2 Tri 66.2 Tri 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) 5 (-1;-) NPD 6 (-1;-) U-value (EN 67) NPD NPD NPD NPD 0,07 0,07 0,07 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86/7/8 86/6/8 84/6/8 84/6/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 64/16/11 6/16/11 60/16/10 59/16/10 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 86
387 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Stopray LamiSmart 24 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Stopray LamiSmart 24, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Stopray LamiSmart 24 characteristics in : AVCP Systems 44.1 LamiSmart LamiSmart Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) 6 (-1;-) U-value (EN 67) NPD NPD 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 24/5/28 2/4/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14/8/0 1/5/ Durability PASS PASS 26th of February 2015 Primary Sales & Strategic, Marketing Director, Building 87
388 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Stopray LamiSmart 24 (laminated with Planibel Bronze) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Stopray LamiSmart 24 (laminated with Planibel Bronze), intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Stopray LamiSmart 24 (laminated with Planibel Bronze) characteristics in : AVCP Systems 44.1 LamiSmart Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 NPD. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) U-value (EN 67) NPD 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 16/16/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 10/20/ Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 88
389 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Stopray LamiSmart 24 (laminated with Planibel Dark Blue) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Stopray LamiSmart 24 (laminated with Planibel Dark Blue), intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Stopray LamiSmart 24 (laminated with Planibel Dark Blue) characteristics in : AVCP Systems 44.1 LamiSmart Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 NPD. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) U-value (EN 67) NPD 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 18/18/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 10/14/ Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 89
390 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Stopray LamiSmart 24 (laminated with Planibel Green) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Stopray LamiSmart 24 (laminated with Planibel Green), intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Stopray LamiSmart 24 (laminated with Planibel Green) characteristics in : AVCP Systems 44.1 LamiSmart Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 NPD. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) U-value (EN 67) NPD 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 21/2/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 10/16/ Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 90
391 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Stopray LamiSmart 24 (laminated with Planibel Grey) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Stopray LamiSmart 24 (laminated with Planibel Grey), intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Stopray LamiSmart 24 (laminated with Planibel Grey) characteristics in : AVCP Systems 44.1 LamiSmart Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 NPD. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 NPD 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) NPD 7. Pendulum body impact resistance (EN 12600) 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 4 (-1;-2) U-value (EN 67) NPD 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 15/14/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 10/18/ Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 91
392 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Burglar resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) P7B P5A P6B P6B P6B P8B P8B 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD NPD U-value (EN 67) 5,0 5,2 5,1 5,1 5,1 4,8 4, 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 82 / 7 / 7 84 / 8 / 8 84 / 8 / 8 84 / 8 / 8 82 / 7 / 7 78 / 7 / 7 69 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 55 / 6 / 6 64 / 6 / 6 6 / 6 / 6 6 / 6 / 6 60 / 6 / 6 51 / 6 / 6 8 / 5 / NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 92
393 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR1 S BR1 NS BR S 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD P6B 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 5,2 5,2 4,7 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 8 / 8 8 / 8 / 8 79 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59 / 6 / 6 59 / 6 / 6 49 / 6 / 6 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 9
394 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems 10- (88-C) Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR2 S BR2 NS BR1 S 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) P7B P6B P4A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 4,9 4,8 5, 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 84 / 8 / 8 78 / 7 / 7 85 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 58 / 6 / 6 49 / 6 / 6 66 / 6 / 6 NPD Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 94
395 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR2 S BR5 S/SG2 S BRS 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD P8B P6B 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 5,1 4,5 4,9 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 81 / 7 / 7 74 / 7 / 7 80 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 54 / 6 / 6 45 / 5 / 5 52 / 6 / 6 NPD Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 95
396 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR1 S BR2 S BR NS 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD PA P6B 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 5,1 5,1 4,6 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 80 / 7 / 7 80 / 7 / 7 74 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 5 / 6 / 6 5 / 6 / 6 45 / 5 / 5 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 96
397 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR2 S BR1 S BR1 S 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD P2A PA 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 4,9 5, 5, 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 79 / 7 / 7 8 / 8 / 8 8 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 51 / 6 / 6 60 / 6/ 6 60 / 6 / 6 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 97
398 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR2 S BR7 NS BR4 S / SG1 S 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) P2A P8B P6B 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 5,1,6 4,6 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 8 / 8 62 / 6 / 6 78 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 58 / 6 / 6 27 / 5 / 5 48 / 6 / 6 66 NPD Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 98
399 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR6 NS BR1 NS BR5 NS 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) P8B P2A P7B 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67),9 5,2 4, 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 61 / 6 / 6 84 / 8 / 8 69 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 5 / 5 60 / 6 / 6 6 / 5 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 99
400 CE Marking of Double Glazing Unit EN : A2:2010 Stratobel (Bullet resistant) in DGU Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN : A2:2010 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR4 NS / BR6 S BR6 NS BR5 NS 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) P4A P6B NPD 7. Pendulum body impact resistance (EN 12600) 1B1 / 1B1 1B1 / 1B1 1B1 / 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 2,6 2,4 2,5 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 65 / 12 / / 11 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 8 / 8 27 / 7 / 7 / 8 / 8 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 400
401 CE Marking of Double Glazing Unit EN : A2:2010 Stratobel (Bullet resistant) in DGU Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN : A2:2010 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR7 S BR7 NS SG1 NS 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) P8B P8B P4A 7. Pendulum body impact resistance (EN 12600) 1B1 / 1B1 1B1 / 1B1 1B1 / 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 2,4 2, 2,5 NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 61 / 11 / / 11 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 29 / 8 / 8 25 / 7 / 7 1 / 8 / 8 NPD NPD NPD 14. Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 401
402 CE Marking of Double Glazing Unit EN : A2:2010 Stratobel (Bullet resistant) in DGU Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN : A2:2010 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD 2. Reaction to fire (EN ), 4 NPD. External fire performances, 4 NPD 4. Bullet resistance (EN 106) 1 SG2 NS 5. Explosion resistance (EN 1541) 1 NPD 6. Burglar resistance (EN 56) P8B 7. Pendulum body impact resistance (EN 12600) 1B1 / 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD U-value (EN 67) 2, NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 61 / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 28 / 7 / 7 NPD 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 402
403 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel (Blast resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 1541 NB Stratobel characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 ER1 S ER2 S 6. Burglar resistance (EN 56) P5A P6B 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 5 (-1;-) NPD U-value (EN 67) 5,4 5,0 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 8 / 8 84 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 69 / 7 / 7 59 / 6 / 6 74 NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 40
404 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Color Standard Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Color Standard, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel color standard characteristics in : AVCP.1 Blue.1 Bronze.1 French.1 Medium.1 Grey Systems green Bronze 558 bronze Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 2B2 2B2 2B2 2B2 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-) 2 (-1;-) 2 (-1;-) 2 (-1;-) 2 (-1;-) U-value (EN 67) 5,7 5,7 5,7 5,7 5,7 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 7 / 7 / 7 54 / 6 / 6 58 / 6 / 6 29 / 5 / 5 42 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 68 / 6 / 6 5 / 6 / 6 57 / 6 / 6 2 / 5 / 5 48 / 5 / 5 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 404
405 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Color Standard Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Color Standard, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel color standard characteristics in : AVCP.1 Mat.2 Mat 44.1 Mat 44.2 Mat Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A P2A NPD P1A P2A 7. Pendulum body impact resistance (EN 12600) 2B2 1B1 2B2 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-) (-1;-4) 4 (-1;-2) 5 (-1;-) U-value (EN 67) 5,7 5,6 5,6 5,5 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 67 / 12 / / 12 / / 12 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 61 / 10 / / 10 / / 10 / / 10 / 10 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 405
406 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Color Rainnbow Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Color Rainbow, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel color rainbow characteristics in : AVCP Systems.1 Vanceva 1 Coral Rose.1 Vanceva 2 Aquamarine.1 Vanceva Smoke Grey.1 Vanceva 4 Sahara Sun.1 Vanceva 5 Ruby Red 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 2B2 2B2 2B2 2B2 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-) 2 (-1;-) 2 (-1;-) 2 (-1;-) 2 (-1;-) U-value (EN 67) 5,7 5,7 5,7 5,7 5,7 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 77 / 7 / 7 79 / 7 / 7 78 / 7 / 7 77 / 7 / 7 48 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 7 / 7 71 / 7 / 7 69 / 7 / 7 62 / 6 / 6 6 / 6 / 6 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 406
407 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Color Rainbow Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Color Rainbow, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel color rainbow characteristics in : AVCP Systems.1 Vanceva 6 Sapphire.1 Vanceva 7 Midnight.1 Vanceva 8 Golden light.1 Vanceva 9 Artic Snow 44.1 Vanceva 9 Artic Snow 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 2B2 2B2 2B2 2B2 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-) 2 (-1;-) 2 (-1;-) 2 (-1;-) 4 (-1;-2) U-value (EN 67) 5,7 5,7 5,7 5,7 5,7 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 52 / 6 / 6 50 / 5 / 5 86 / 8 / 8 67 / 12 / / 12 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 57 / 6 / 6 48 / 5 / 5 70 / 7 / 7 61 / 10 / / 10 / 10 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 407
408 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Color Rainbow Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Color Rainbow, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel color rainbow characteristics in : AVCP Systems.1 Vanceva A Cool White 44.1 Vanceva A Cool White.2 Vanceva C00 Pure White.1 Vanceva C Deep Red.1 Vanceva D True Blue 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD P1A P2A NPD NPD 7. Pendulum body impact resistance (EN 12600) 2B2 2B2 1B1 2B2 2B2 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-1;-) 4 (-1;-2) NPD 2 (-1;-) 2 (-1;-) U-value (EN 67) 5,7 5,7 5,7 5,7 5,7 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 8 / 9 / 9 82 / 9 / 9 8 / 6 / 6 16 / 5 / 5 14 / 4 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 72 / 8 / 8 70 / 8 / 8 8 / 47 / 47 5 / 5 / 5 41 / 5 / 5 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 408
409 Stratobel EVA 409
410 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel EVA Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel EVA, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel EVA characteristics with tempered components: AVCP Systems 55.2T 66.2T 68.2T 88.2T T T T 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD NPD U-value (EN 67) 5,5 5,4 5,4 5, 5,2 5,1 4,9 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 8 / 8 85 / 8 / 8 84 / 8 / 8 8 / 8 / 8 81 / 7 / 7 80 / 7 / 7 77 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 67 / 7 / 7 65 / 6 / 6 6 / 6 / 6 61 / 6 / 6 55 / 6 / 6 52 / 6 / 6 47 / 6 / 6 NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 410
411 Stratobel Impression 411
412 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Impression Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel Impression, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel Impression characteristics: AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD U-value (EN 67) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 412
413 Stratobel PC 41
414 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel PC (Burglar resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel PC, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel PC characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) P6B P7B P8B 7. Pendulum body impact resistance (EN 12600) 1(B)1 1(B)1 1(B)1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 5, 5, 5,1 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 85 / 8 / 8 84 / 8 / 8 8 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 67 / 7 / 7 65 / 7 / 7 64 / 6 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 414
415 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel PC (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel PC, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel PC characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR1 NS BR2 NS BR NS BR4 NS / SG1 NS 5. Explosion resistance (EN 1541) 1 NPD NPD NPD ER NS 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1(B)1 1(B)1 1(B)1 1(B)1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD U-value (EN 67) 5, 5, 5,2 5,0 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 85 / 8 / 8 85 / 8 / 8 8 / 8 / 8 80 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 66 / 6 / 6 65 / 6 / 6 60 / 6 / 6 54 / 6 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 415
416 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel PC (Bullet resistant) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel PC, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel PC characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 BR5 NS / SG2 NS BR6 NS BR7 NS 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1(B)1 1(B)1 1(B)1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD U-value (EN 67) 4,7 4,5,6 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 76 / 7 / 7 74 / 7 / 7 58 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 46 / 6 / 6 4 / 5 / 5 25 / 5 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 416
417 CE Marking of Double Glazing Unit EN : A2:2010 Stratobel PC (Bullet resistant) in DGU Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel PC, intended to be used in buildings and construction works, following EN : A2:2010 NB Stratobel PC characteristics in : AVCP Systems 848i i Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 BR6 NS BR7 NS 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 / 1B1 1B1 / 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD U-value (EN 67) 2,6 2, NPD NPD 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 70 / 1 / 1 56 / 11 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 42 / 10 / / 7 / 7 NPD NPD 14. Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 417
418 Stratobel Other products 418
419 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Other products (level ) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel (level products) characteristics in : AVCP Systems 1. Resistance to fire (EN ) 1 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) For 1 characteristics, see 8. Resistance against sudden temperature change and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 419
420 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Other products (level 1) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel (level 1 products) characteristics in : AVCP Systems 1. Resistance to fire (EN ) 1 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) 8. Resistance against sudden temperature change and temperature differentials 4 For 1 characteristics, see 9. Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 420
421 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Other products (level ) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel (level products) characteristics in : AVCP Systems 1. Resistance to fire (EN ) 1 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) For 1 characteristics, see 8. Resistance against sudden temperature change and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 421
422 CE Marking of Laminated glass EN 14449: AC:2005 Stratobel Other products (level 1) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratobel, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratobel (level 1 products) characteristics in : AVCP Systems 1. Resistance to fire (EN ) 1 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) 8. Resistance against sudden temperature change and temperature differentials 4 For 1 characteristics, see 9. Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 422
423 Stratophone 42
424 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone clear (22.x,.x) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) (-1;-5) (-1;-4) 5 (-1;-) 6 (0;-) U-value (EN 67) 5,7 5,7 5,7 5,6 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 90 / 8 / 8 90 / 8 / 8 89 / 8 / 8 89 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 79 / 7 / 7 77 / 7 / 7 76 / 7 / 7 74 / 7 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 424
425 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone clear (44.x) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A PA-P4A P5A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 7 (-0, -2) 7 (0;-2) 7 (0;-) 8 (-1;-) U-value (EN 67) 5,6 5,6 5,5 5, 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88 / 8 / 8 88 / 8 / 8 88 / 8 / 8 88 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 7 / 7 / 7 72 / 7 / 7 70 / 7 / 7 69 / 7 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 425
426 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone clear (55.x, 66.x, 88.x) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone characteristics in : AVCP Systems Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 8 (-1;-) 9 (-1;-) 40 (-1;-) 40 (-1;-) 41 (-1;-2) U-value (EN 67) 5,6 5,5 5,5 5,4 5, 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 8 / 8 87 / 8 / 8 86 / 8 /8 86 / 8 / 8 84 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 70 / 7 / 7 69 / 7 / 7 68 / 7 / 7 66 / 7 / 7 62 / 6 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 426
427 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone iplus Energy N Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone iplus Energy N, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone iplus Energy N characteristics in : AVCP Systems Energy N Energy N Energy N Energy N Energy N Energy N 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 5 (-1;-) 6 (0;-) 7 (0;-) 7 (0;-) 40 (-1;-) 40 (-1;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,01 0,01 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 80 / 7 / 7 80 / 7 / 7 79 / 7 / 7 79 / 7 / 7 77 / 7 / 6 77 / 7 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 41 / / 41 / 25 9 / 41 / 24 9 / 41 / 2 8 / 41 / 20 7 / 41 / 19 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 427
428 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone iplus I-Top Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone iplus I-Top, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone iplus I-Top characteristics in : AVCP Systems 22.1 I-Top 22.2 I-Top.1 I-Top 44.1 I-Top 44.2 I-Top 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 2 (-2;-5) (-1;-4) 5 (-1;-) 7 (-0, -) 7 (0;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 6 / 7 87 / 6 / 7 86 / 6 / 7 85 / 5 / 7 85 / 5 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 57 / 29 / / 29 / / 28 / / 28 / / 28 / 16 NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 428
429 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone iplus Light Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone iplus Light, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone iplus Light characteristics in : AVCP Systems 22.1 Light 22.2 Light.1 Light 44.1 Light 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) (-2;-5) (-1;-4) 5 (-1;-) 7 (-0, -) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 71/19/21 71/19/21 71/19/21 71/19/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 41/4/4 41/4/ 41/4/29 40/4/26 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 429
430 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone iplus Top 1.0 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone iplus Top 1.0, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone iplus Top 1.0 characteristics in : AVCP Systems 22.1 Top Top Top Top Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) (-2;-5) (-1;-4) 5 (-1;-) 6 (0;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 77 / 15 / / 15 / / 15 / / 15 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 45 / 42 / 45 / 42 / 2 45 / 42 / 0 44 / 42 / 29 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 40
431 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone iplus Top 1.0 Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone iplus Top 1.0, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone iplus Top 1.0 characteristics in : AVCP Systems 44.1 Top Top Top Top Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 7 (-0, -) 7 (0;-) 40 (-1;-) 40 (-1;-) U-value (EN 67) NPD NPD NPD NPD 0,01 0,01 0,01 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 75 / 15 / / 15 / / 14 / / 14 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 44 / 42 / 28 4 / 42 / / 42 / / 42 / 2 NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 41
432 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone Low-e Top N Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone Low-e Top N, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone Low-e Top N characteristics in : AVCP Systems.1 Top N.2 Top N 44.1 Top N 44.2 Top N 66.1 Top N 66.2 Top N 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 5 (-1;-) 6 (0;-) 7 (-0, -) 7 (0;-) 40 (-1;-) 40 (-1;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,04 0,04 0,04 0,04 0,04 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 6 / 8 86 / 6 / 8 85 / 6 / 8 85 / 6 / 8 84 / 6 / 8 8 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 60 / 25 / / 25 / / 25 / / 25 / /24 / / 24 / 14 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 42
433 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone Low-e Top N+ Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone Low-e Top N+, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone Low-e Top N+ characteristics in : AVCP Systems.1 Top N+.2 Top N Top N Top N Top N Top N+ 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 5 (-1;-) 6 (0;-) 7 (-0, -) 7 (0;-) 40 (-1;-) 40 (-1;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,0 0,0 0,0 0,0 0,0 0,0 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86 / 6 / 7 86 / 6 / 7 85 / 6 / 7 85 / 6 / 7 8 / 6 / 7 8 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 55 / 29 / / 29 / 19 5 / 29 / 18 5 / 29 / /29 / / 29 / 15 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 4
434 CE Marking of Laminated glass EN 14449: AC:2005 Stratophone Low-e Tri Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Stratophone Low-e Tri, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB Stratophone Low-e Tri characteristics in : AVCP Systems.1 Tri.2 Tri 44.1 Tri 44.2 Tri 55.2 Tri 66.2 Tri 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD P1A-P2A NPD P1A-P2A NPD P1A-P2A 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 5 (-1;-) 6 (0;-) 7 (-0, -) 7 (0;-) 40 (-1;-) 40 (-1;-) U-value (EN 67) NPD NPD NPD NPD NPD NPD 0,07 0,07 0,07 0,07 0,07 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87 / 7 / 8 87 / 7 / 8 86 / 7 / 8 86 / 6 / 8 84 / 6 / 8 84 / 6 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 66 / 17 / / 17 / / 16 / 11 6 / 16 / / 16 / / 16 / 10 NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 44
435 Sunergy 45
436 CE Marking of Coated glass - EN :2004 Sunergy Clear (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Clear, intended to be used in buildings and construction works, following EN :2004 NB Sunergy Clear characteristics in : AVCP Systems mm 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 29 (-2;-5) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD NPD 0,28 0,28 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 69 / 10 / 9 69 / 10 / 9 68 / 10 / 9 67 / 10 / 8 66 / 10 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 56 / 10 / / 10 / / 10 / 9 52 / 10 / 9 50 / 10 / Durability PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 46
437 CE Marking of Heat strengthened glass - EN 186-2:2004 Sunergy Clear Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Clear Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Sunergy Clear Heat strengthened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,28 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 69 / 10 / 9 68 / 10 / 9 67 / 10 / 8 66 / 10 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 56 / 10 / / 10 / 9 52 / 10 / 9 50 / 10 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 47
438 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Sunergy Clear Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Clear Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Sunergy Clear Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,28 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 69 / 10 / 9 68 / 10 / 9 67 / 10 / 8 66 / 10 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 56 / 10 / / 10 / 9 52 / 10 / 9 50 / 10 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 48
439 CE Marking of Coated glass - EN :2004 Sunergy Azur (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Azur, intended to be used in buildings and construction works, following EN :2004 NB Sunergy Azur characteristics in : AVCP Systems 4 mm 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1 A1. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 0 (-2;-4) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD NPD 0,28 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 60 / 10 / 8 56 / 10 / 7 52 / 9 / 7 48 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 40 / 10 / 7 4 / 10 / 6 29 / 9 / 6 26 / 9 / Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 49
440 CE Marking of Heat strengthened glass - EN 186-2:2004 Sunergy Azur Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Azur Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Sunergy Azur Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 10 / 7 52 / 9 / 7 48 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 10 / 6 29 / 9 / 6 26 / 9 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 440
441 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Sunergy Azur Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Azur Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Sunergy Azur Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) NPD NPD NPD 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 10 / 7 52 / 9 / 7 48 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 4 / 10 / 6 29 / 9 / 6 26 / 9 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 441
442 CE Marking of Coated glass - EN :2004 Sunergy Dark Blue (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Dark blue, intended to be used in buildings and construction works, following EN :2004 NB Sunergy Dark Blue characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 4,1 4,1 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 40 / 9 / 6 5 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 26 / 9 / 6 21 / 9 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 442
443 CE Marking of Heat strengthened glass - EN 186-2:2004 Sunergy Dark Blue Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Dark Blue Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Sunergy Dark Blue Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 4,1 4,1 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 40 / 9 / 6 5 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 26 / 9 / 6 21 / 9 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 44
444 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Sunergy Dark Blue Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Dark Blue Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Sunergy Dark Blue Thermally toughened or Heat soaked thermally toughened characteristics in AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 4,1 4,1 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 40 / 9 / 6 5 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 26 / 9 / 6 21 / 9 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 444
445 CE Marking of Coated glass - EN :2004 Sunergy Green (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Green, intended to be used in buildings and construction works, following EN :2004 NB Sunergy Green characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 4,1 4,1 4,0 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 10 / 7 52 / 9 / 7 48 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 9 / 6 26 / 9 / 6 22 / 9 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 445
446 CE Marking of Heat strengthened glass - EN 186-2:2004 Sunergy Green Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Green Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Sunergy Green Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 4,1 4,1 4,0 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 10 / 7 52 / 9 / 7 48 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 9 / 6 26 / 9 / 6 22 / 9 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 446
447 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Sunergy Green Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Green Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Sunergy Green Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 10 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD 2. Reaction to fire (EN ), 4 A1 A1 A1. External fire performances, 4 NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 1C2 1C1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) 4 (-2;-) U-value (EN 67) 4,1 4,1 4,0 0,28 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 56 / 10 / 7 52 / 9 / 7 48 / 9 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 1 / 9 / 6 26 / 9 / 6 22 / 9 / Durability PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 447
448 CE Marking of Coated glass - EN :2004 Sunergy Grey (annealed) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Grey, intended to be used in buildings and construction works, following EN :2004 NB Sunergy Grey characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 4,1 4,1 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 9 / 5 26 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 9 / 6 24 / 9 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 448
449 CE Marking of Heat strengthened glass - EN 186-2:2004 Sunergy Grey Heat strengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Grey Heat strengthened, intended to be used in buildings and construction works, following EN 186-2:2004 NB Sunergy Grey Heat strengthened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD 8. Resistance against sudden temperature change and temperature differentials K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 4,1 4,1 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 9 / 5 26 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 9 / 6 24 / 9 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 449
450 CE Marking of Thermally toughened glass - EN :2004 CE Marking of Heat soaked Thermally toughened glass - EN :2005 Sunergy Grey Thermally toughened or Heat soaked thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Sunergy Grey Thermally toughened or Heat soaked thermally toughened, intended to be used in buildings and construction works, following EN :2004 / :2005 NB Sunergy Grey Thermally toughened or Heat soaked thermally toughened characteristics in : AVCP Systems 6 mm 8 mm 1. Resistance to fire (EN ) 1 NPD NPD 2. Reaction to fire (EN ), 4 A1 A1. External fire performances, 4 NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD 6. Burglar resistance (EN 56) NPD NPD 7. Pendulum body impact resistance (EN 12600) 1C2 NPD 8. Resistance against sudden temperature change and temperature differentials K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) 1 (-2;-) 2 (-1;-2) U-value (EN 67) 4,1 4,1 0,28 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 4 / 9 / 5 26 / 8 / Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 0 / 9 / 6 24 / 9 / Durability PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 450
451 SunEwat 451
452 CE Marking of Laminated glass EN 14449: AC:2005 SunEwat L 44.4 Heat stengthened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named SunEwat L, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB AVCP Systems Surface covered by solar celles regarding to the surface of the glass 44.4 SunEwat L characteristics in : 0 % 10 % 20 % 0 % 40 % 50 % 60 % 70 % 80 % 90 % 100 % 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials K 100 K 100 K 100 K 100 K 100 K 100 K 100 K 100 K 100 K 100 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD U-value (EN 67) 5,6 5,6 5,6 5,6 5,6 5,6 5,6 5,6 5,6 5,6 5,6 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88/8/8 79/8/11 70/8/1 62/8/16 5/8/18 44/9/21 5/9/2 26/9/26 18/9/28 9/9/1 0/9/ 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 75/7/7 68/9/9 60/9/11 5/10/1 45/11/15 8/12/17 0/12/19 2/1/21 15/14/2 8/15/25 0/16/27 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 452
453 CE Marking of Laminated glass EN 14449: AC:2005 SunEwat L 44.4 thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named SunEwat L, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB AVCP Systems Surface covered by solar celles regarding to the surface of the glass 44.4 SunEwat L characteristics in : 0 % 10 % 20 % 0 % 40 % 50 % 60 % 70 % 80 % 90 % 100 % 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD U-value (EN 67) 5,6 5,6 5,6 5,6 5,6 5,6 5,6 5,6 5,6 5,6 5,6 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 88/8/8 79/8/11 70/8/1 62/8/16 5/8/18 44/9/21 5/9/2 26/9/26 18/9/28 9/9/1 0/9/ 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 75/7/7 68/9/9 60/9/11 5/10/1 45/11/15 8/12/17 0/12/19 2/1/21 15/14/2 8/15/25 0/16/27 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 45
454 CE Marking of Laminated glass EN 14449: AC:2005 SunEwat XL 55.6 thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named SunEwat XL, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB AVCP Systems Surface covered by solar celles regarding to the surface of the glass 55.6 SunXEwat L characteristics in : 0 % 10 % 20 % 0 % 40 % 50 % 60 % 70 % 80 % 90 % 100 % 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD U-value (EN 67) 5, 5, 5, 5, 5, 5, 5, 5, 5, 5, 5, 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87/8/8 78 /8/9 70/8/9 61/8/10 52/8/11 44/8/12 5/7/12 26/7/1 17/7/14 9/7/14 0/8/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 66/7/7 60/7/8 5/8/9 46/8/9 40/8/10 /9/11 26/9/12 20/9/1 1/9/1 7/10/14 0/10/15 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 454
455 CE Marking of Laminated glass EN 14449: AC:2005 SunEwat XL 66.6 thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named SunEwat XL, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB AVCP Systems Surface covered by solar celles regarding to the surface of the glass 66.6 SunEwat XL characteristics in : 0 % 10 % 20 % 0 % 40 % 50 % 60 % 70 % 80 % 90 % 100 % 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD U-value (EN 67) 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 87/8/8 77/8/9 69/8/9 60/8/10 52/8/11 4/8/12 4/7/12 26/7/1 17/7/14 9/7/14 0/8/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 64/6/6 58/6/7 51/7/8 45/7/9 9/8/10 2/8/11 26/8/11 19/9/12 1/9/1 6/10/14 0/10/15 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 455
456 CE Marking of Laminated glass EN 14449: AC:2005 SunEwat XL 88.6 thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named SunEwat XL, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB AVCP Systems Surface covered by solar celles regarding to the surface of the glass 88.6 SunEwat XL characteristics in : 0 % 10 % 20 % 0 % 40 % 50 % 60 % 70 % 80 % 90 % 100% 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD U-value (EN 67) 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 86/7/7 76/7/8 68/7/8 59/7/9 51/7/9 42/7/10 4/6/11 25/6/11 17/6/12 8/6/1 0/7/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 62/5/5 56/5/6 50/6/7 44/6/7 7/7/8 1/7/9 25/7/10 19/8/11 12/8/11 6/8/12 0/9/1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 456
457 CE Marking of Laminated glass EN 14449: AC:2005 SunEwat XL thermally toughened Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named SunEwat XL, intended to be used in buildings and construction works, following EN 14449: AC:2005 NB AVCP Systems Surface covered by solar celles regarding to the surface of the glass SunEwat XL characteristics in : 0 % 10 % 20 % 0 % 40 % 50 % 60 % 70 % 80 % 90 % 100% 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 1B1 8. Resistance against sudden temperature change and temperature differentials K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 200 K 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD U-value (EN 67) 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 5,0 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0,89 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 85/7/7 74/7/8 66/7/8 58/7/9 49/7/9 41/7/10 /6/11 25/6/11 16/6/12 8/6/1 0/7/ Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 59/5/5 5/5/6 47/6/7 41/6/7 5/7/8 29/7/9 2/7/10 18/8/11 12/8/11 6/8/12 0/9/1 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 457
458 Thermally toughened glass for Shower enclosure 458
459 CE Marking of Thermally toughened glass for Shower enclosure EN Planibel Thermally toughened for shower enclosure Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Planibel Thermally toughened, intended to be used in Shower enclosure, following EN NB Planibel Thermally toughened characteristics in : mm 4 mm 5 mm 6 mm 8 mm Cleanability Pass Impact resistance / Shatter properties Pass Durability Pass 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 459
460 Thermobel 460
461 CE Marking of Insulating glass unit - EN : A2:2010 Thermobel (level products) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Thermobel, intended to be used in buildings and construction works, following EN : A2:2010 NB Thermobel (level products) characteristics in : AVCP Systems 1. Resistance to fire (EN ) 1 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) For 1 characteristics, see 8. Resistance against sudden temperature change and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 461
462 CE Marking of Insulating glass unit - EN : A2:2010 Thermobel (level 1 products) Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Thermobel, intended to be used in buildings and construction works, following EN : A2:2010 NB Thermobel (level 1 products) characteristics in : AVCP Systems 1. Resistance to fire (EN ) 1 2. Reaction to fire (EN ), 4. External fire performances, 4 4. Bullet resistance (EN 106) 1 5. Explosion resistance (EN 1541) 1 6. Burglar resistance (EN 56) 7. Pendulum body impact resistance (EN 12600) 8. Resistance against sudden temperature change and temperature differentials 4 For 1 characteristics, see 9. Wind, snow, permanent and imposed load resistance Direct airborne sound reduction (EN 12758): Rw (C;Ctr) U-value (EN 67) 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e 14. Durability PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 462
463 Thermobel VIP 46
464 CE Marking of Insulating glass unit - EN : A2:2010 Thermobel VIP Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Thermobel VIP, intended to be used in buildings and construction works, following EN : A2:2010 NB Thermobel VIP characteristics in : AVCP Systems (VIP 14 mm) (VIP 18 mm) (VIP 20 mm) (VIP 14 mm) (VIP 18 mm) (VIP 20 mm) 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD NPD 11. U-value (EN 67) 0,4 0, 0, 0,4 0, 0, 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 464
465 CE Marking of Insulating glass unit - EN : A2:2010 Thermobel VIP Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Thermobel VIP, intended to be used in buildings and construction works, following EN : A2:2010 NB Thermobel VIP characteristics in : AVCP Systems (VIP 14 mm) (VIP 18 mm) (VIP 20 mm) (VIP 40 mm) 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD 5 (-1;-) NPD 11. U-value (EN 67) 0,4 0, 0, 0, Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 465
466 CE Marking of Insulating glass unit - EN : A2:2010 Thermobel VIP Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Thermobel VIP, intended to be used in buildings and construction works, following EN : A2:2010 NB Thermobel VIP characteristics in : AVCP * * * * * * Systems (VIP 14 mm) (VIP 18 mm) (VIP 20 mm) (VIP 14 mm) (VIP 18 mm) (VIP 20 mm) * glass glued with a steel plate of 0,75 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and temperature differentials 4 NPD NPD NPD NPD NPD NPD 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 8 (-2;-5) 11. U-value (EN 67) 0,4 0, 0, 0,4 0, 0, 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 466
467 CE Marking of Insulating glass unit - EN : A2:2010 Thermobel VIP Avenue Jean Monnet Louvain-la-Neuve - Belgium Tel.: +2 - (0) Fax: +2 - (0) Declare, under his sole responsibility, the following characteristics for the CE Marking of the glass products named Thermobel VIP, intended to be used in buildings and construction works, following EN : A2:2010 NB Thermobel VIP characteristics in : AVCP Systems 4*-16-4* (VIP 14 mm) 4*-20-4* (VIP 18 mm) 4*-22-4* (VIP 20 mm) ** (VIP 14 mm) ** (VIP 16 mm) ** (VIP 14 mm) * glass glued with a steel plate of 0,75 mm / ** glass glued with a steel plate of 2 mm 1. Resistance to fire (EN ) 1 NPD NPD NPD NPD NPD NPD 2. Reaction to fire (EN ), 4 NPD NPD NPD NPD NPD NPD. External fire performances, 4 NPD NPD NPD NPD NPD NPD 4. Bullet resistance (EN 106) 1 NPD NPD NPD NPD NPD NPD 5. Explosion resistance (EN 1541) 1 NPD NPD NPD NPD NPD NPD 6. Burglar resistance (EN 56) NPD NPD NPD NPD NPD NPD 7. Pendulum body impact resistance (EN 12600) NPD NPD NPD NPD NPD NPD 8. Resistance against sudden temperature change and 4 NPD NPD NPD NPD NPD NPD temperature differentials 9. Wind, snow, permanent and imposed load resistance 4 NPD NPD NPD NPD NPD NPD 10. Direct airborne sound reduction (EN 12758): Rw (C;Ctr) NPD NPD NPD NPD NPD 42 (-2;-5) 11. U-value (EN 67) 0,4 0, 0, 0,4 0, 0, 12. Light transmission/reflection (EN 410): τ v / ρ v / ρ' v NPD NPD NPD NPD NPD NPD 1. - Solar transmission/reflection/factor (EN 410): τ e / ρ e / ρ' e NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD 14. Durability PASS PASS PASS PASS PASS PASS 2rd of February 2015 Primary Sales & Strategic, Marketing Director, Building 467
468 Translations 468
469 English Bulgarian (български) CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light teflection Solar energy transmission Solar energy reflection Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass СЕ маркировка Характеристики Пожароустойчивост Реакция към огън Външна пожароустойчивост Куршумоустойчивост Взривоустойчивост Устойчивост на вандализъм Устойчивост на удар от двежещи се тела Устойчивост на резки температурни промени и температурни разлики Устойчивост на вятър, сняг, постоянно или временно натоварване Редукция на звуци, предавани директно по въздух Термални характеристики Емисивитет U-фактор Радиационни характеристики Светлопреминаване Отразяване на светлина Прминаване на слънчева енергия Отразяване на слънчева енергия Флоатно стъкло Орнаментно стъкло Орнаментно армирано стъло Стъкло с покритие Термично закалено флоатно безопасно стъкло Термично закалено флоатно стъкло с "heat soak" тест Топлинно заздравено флоатно стъкло Изолиращи елементи Ламинирано стъкло и ламинирано безопасно стъкло Пожароустойчиво стъкло 469
470 English čeština CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light reflection Solar energy transmission Solar energy reflection CE značení Vlastnosti Požární odolnost Reakce na oheň Ukazatel odolnosti proti vnějšímu požáru Odolnost proti průstřelu Odolnost proti výbuchu Odolnost proti násilnému vniknutí Odolnost proti kyvadlovému nárazu Odolnost proti náhlým změnám teploty a teplotním rozdílům Odolnost proti zatížení větrem, sněhem, trvalému a užitnému zatížení Přímá vzduchová neprůzvučnost Tepelné vlastnosti Emisivita Součinitel prostupu tepla U, Ug Světelné vlastnosti Světelný činitel prostupu Světelný činitel odrazu Činitel prostupu přímého slunečního záření Činitel odrazu přímého slunečního záření Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Základní sodnovápenatokřemičité sklo float Základní sodnovápenatokřemičité vzorované sklo Základní sodnovápenatokřemičité vzorované sklo s drátěnou vložkou Sklo s povlakem Tepelně tvrzené sodnovápenatokřemičité bezpečnostní sklo Tepelně tvrzené prohřívané sodnovápenatokřemičité bezpečnostní sklo (HST) Tepelně zpevněné sodnovápenatokřemičité sklo Izolační skla Vrstvená skla a vrstvená bezpečnostní skla Protipožární sklo 470
471 English Dansk CE Marking CE mærkning Characteristics Karakteristik Resistance to fire Modstand mod brand Reaction to fire Reaktion ved brand External fire performance Ekstern brandmodstand Bullet resistance Modstand mod skud Explosion resistance Modstand mod eksplosion Burglar resistance Modstand mod indbrud Pendulum body impact resistance Pendultest (personsikkerhed) Resistance against sudden temperature changes and temperature differentials Modstand mod pludselige temperatursvingninger og temperaturgradienter Wind, snow, permanent and imposed load resistance Vind-, sne- og langtidslast Direct airborne sound insulation Direkte luftbåren Lydreduktion Thermal properties Varmeisolering Emissivity Emissivitet U-value U-værdi Radiation properties Strålingsegenskaber Light transmission Sollystransmittans Light reflection Sollysreflektans Solar energy transmission Solenergitransmittans Solar energy reflection Solenergireflektans Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Kalk-soda-silikat floatglas Kalk-soda-silikat ornament glas Kalk-soda-silikat ornament trådglas Belagt glas Termisk hærdet glas Heat soaked termisk hærdet kalk-soda-silikat glas Varmeforstærket glas Termoruder Lamineret glas og lamineret sikkerhedsglas Brandbeskyttende glas 471
472 English Deutsch CE Marking CE Kennzeichnung Characteristics Eigenschaften Resistance to fire Feuerwiderstand Reaction to fire Brandverhalten External fire performance Verhalten bei Beanspruchungdurch Feuer von außen Bullet resistance Durchschusshemmung Explosion resistance Sprengwirkungshemmung Burglar resistance Einbruchhemmung Pendulum body impact resistance Pendelschlagwiderstand Resistance against sudden temperature changes and temperature differentials Beständigkeit gegen plötzlichetemperaturwechsel und Temperaturunterschiede Wind, snow, permanent and imposed load resistance Widerstand gegen Schnee-, Wind-, Dauerlasten bzw. sonstige Lasten Direct airborne sound insulation Direkte Luftschalldämmung Thermal properties Thermische Eigenschaften Emissivity Emissivität U-value U-Wert Radiation properties Strahlungsphysikalische Eigenschaften Light transmission Lichttransmission Light reflection Lichtreflexion Solar energy transmission Energietransmission Solar energy reflection Energiereflexion Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Gefloatetes Natronkalk-Silicatglas Ornamentglas aus Natronkalk-Silicatglas Drahtornamentglas aus Natronkalk-Silicatglas Beschichtetes Glas Thermisch vorgespanntes Kalknatron-Einscheibensicherheitsglas Heißgelagertes thermisch vorgespanntes Kalknatron-Einscheibensicherheitsglas Teilvorgespanntes Kalknatronglas Isolierglas Verbundglas und Verbundsicherheitsglas Feuerbeständiges Glas 472
473 English eesti keel CE Marking CE märgistus Characteristics Omadused Resistance to fire Tulekindlus Reaction to fire Põlevus External fire performance Vastupidavus välisele tulele Bullet resistance Kuulikindlus Explosion resistance Plahvatuskindlus Burglar resistance Vandalismikindlus Pendulum body impact resistance Vastupidavus pehme keha löögile (pendeltest) Resistance against sudden temperature changes and temperature differentials Vastupidavus järskudele temperatuurimuutustele ja temperatuuri erinevustele Wind, snow, permanent and imposed load resistance Vastupidavus tuule-, lume-, püsi- ja kasuskoormusele Direct airborne sound insulation Otsene õhuheli isolatsioon Thermal properties Soojuslikud omadused Emissivity Emissiivsus U-value U-väärtus Radiation properties Kiirguslikud omadused Light transmission Valguse läbivus Light reflection Valguse peegeldus Solar energy transmission Päikeseenergia läbivus Solar energy reflection Päikeseenergia peegeldus Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Lubi-liiv-floatklaas Lubi-liiv-ornamentklaas Sarrustatud Lubi-liiv-ornamentklaas Pindkattega klaas Termiliselt karastatud lubi-liiv-turvaklaas Heat soaked termiliselt karastatud lubi-liiv-turvaklaas Termiliselt tugevdatud lubiliivklaas Klaaspakett Lamineeritud klaas ja lamineeritud turvaklaas Tuletõkkeklaas 47
474 English ελληνικα CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light reflection Solar energy transmission Solar energy reflection Σηµα CE Χαρακτηριστικα Αντσταση στην φωτια Αντιδραση στην φωτια Επιδοση σε εξωτερικη φωτια Αντισταση σε σφαιρα Αντισταση σε εκρηξη Αντισταση σε διαρρηξη Αντισταση σε κρουση εκκρεµων αντικειµενων Αντισταση κατα ξαφνικων αλλαγων θερµοκρασιας και διαφορων θερµοκρασιων Μονιµη και επιβαλλοµενη αντισταση σε ανεµοπιεση και πιεση χιονιου Μονωση κατα απευθειας αεροµεταφεροµενου θορυβου θερµικες ιδιοτητες Εκποµπη Συντελεστης θερµοαγωγιµοτητας Ιδιοτητες ακτινοβολιας Μεταδοση φωτως Αντανακλαση φωτως Μεταδοση ηλιακης ενεργειας Αντανακλαση ηλιακης ενεργειας Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Βασικο γυαλι σοδας Βασικο εκτυπωµενο γυαλι σοδας (διαµαντε) Βασικο εκτυπωµενο γυαλι σοδας µε συρµα Επιστρωµενος υαλοπινακας Θερµικα σκληρηµενο βασικο γυαλι σοδας ασφαλειας Θερµικα εµποτισµενου σκληρηµενου βασικου γυαλιου σοδας ασφαλειας Θερµικα ενισχυµενο βασικο γυαλι σοδας ιπλοι µονωτικοι υαλοπινακες Λαµιναρισµενος υαλοπινακας και λαµιναρισµενος υαλοπινακας ασφαλειας Πυραντοχος υαλοπινακας 474
475 English español CE Marking Marcado CE Characteristics Características Resistance to fire Resistencia al fuego Reaction to fire Reacción al fuego External fire performance Prestaciones de comportamiento frente a fuego exterior Bullet resistance Resistencia a las balas Explosion resistance Resistencia a las explosiones Burglar resistance Resistencia a la agresión Pendulum body impact resistance Resistencia al impacto de cuerpo pendular Resistance against sudden temperature changes and temperature differentials Resistencia a variaciones bruscos de temperatura y a temperaturas diferenciales Wind, snow, permanent and imposed load resistance Reistencia a las cargas de viento y nieve, y a las cargas permanentes e impuestas Direct airborne sound insulation Aislamiento al ruido aereo directo Thermal properties Propiedades térmicas Emissivity Emisividad U-value Valor U Radiation properties Propiedades ante la radiación Light transmission Transmisión luminosa Light reflection Reflexión luminosa Solar energy transmission Transmisión de la energía solar Solar energy reflection Reflexión de la energía solar Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Vidrio flotado de base silicato sodo-cálcico Vidrio impreso de base silicato sodo-cálcico Vidrio impreso armado de base silicato sodo-cálcico Vidrio de capa Vidrio de silicato sodo-cálcico de seguridad templado térmicamente Vidrio de silicato sodo-cálcico de seguridad templado y con tratamiento Heat Soak Vidrio de silicato sodo-cálcico de seguridad termoendurecido Unidad de vidrio aislante Vidrio laminado y vidrio laminado de seguridad Vidrio resistente al fuego 475
476 English français CE Marking Marquage CE Characteristics Caractéristiques Resistance to fire Résistance au feu Reaction to fire Réaction au feu External fire performance Performances de comportement vis-à-vis d'un feu extérieur Bullet resistance Résistance aux balles Explosion resistance Résistances aux explosions Burglar resistance Résistance aux effractions Pendulum body impact resistance Résistance à l'impact d'un pendule Resistance against sudden temperature changes and temperature differentials Résistances aux variations brutales de température et aux températures différentielles Wind, snow, permanent and imposed load resistance Résistance aux charges dues au vent et à la neige, aux charges permanentes et imposées Direct airborne sound insulation Isolation au bruit aérien direct Thermal properties Propriétés thermiques Emissivity Emissivité U-value Coefficient U Radiation properties Propriétés de rayonnement Light transmission Transmission lumineuse Light reflection Réflexion lumineuse Solar energy transmission Transmission du rayonnement solaire Solar energy reflection Reflexion du rayonnement solaire Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Verre float de silicate sodo-calcique de base Verre imprimé de silicate sodo-calcique de base Verre imprimé armé de silicate sodo-calcique de base Verre à couche Verre de silicate sodo-calcique de sécurité trempé thermiquement Verre de silicate sodo-calcique de sécurité trempé et traité Heat Soak Verre de silicate sodo-calcique durci thermiquement Vitrage isolant préfabriqué scellé Verre feuilleté et verre feuilleté de sécurité Verre résistant au feu 476
477 English Italiano CE Marking Marcatura CE Characteristics Caratteristiche Resistance to fire Resistenza al fuoco Reaction to fire Reazione al fuoco External fire performance Resistenza al fuoco proveniente dall esterno Bullet resistance Resistenza ai proiettile Explosion resistance Resistenza all' esplosione Burglar resistance Resistenza agli attacchi manuali Pendulum body impact resistance Resistenza agli urti (Prova del pendolo) Resistance against sudden temperature changes and temperature differentials Resistenza agli sbalzi improvvisi di temperatura e alle differenze di temperatura Wind, snow, permanent and imposed load resistance Resistenza a carichi di vento, neve e ai carichi permanti Direct airborne sound insulation Isolamento al rumore aereo diretto Thermal properties Proprietà termiche Emissivity Emissività U-value Valore U Radiation properties Proprietà di irraggiamento Light transmission Trasmissione luminosa Light reflection Riflessione luminosa Solar energy transmission Solar energy reflection Trasmissione energetica diretta Riflessione energetica Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Prodotti di base di vetro di silicato sodo-calcico Vetro float Prodotti di base di vetro di silicato sodo-calcico Vetro stampato Prodotti di base di vetro di silicato sodo-calcico Vetro stampato armato Vetri rivestiti Vetro di silicato sodo-calcico di sicurezza temprato termicamente Vetro di silicato sodo-calcico di sicurezza temprato e trattato Heat Soak Vetro di silicato sodo-calcico di indurito termicamente Vetrate isolanti Vetro stratificato e vetro stratificato di sicurezza Vetro resistente al fuoco 477
478 English latviešu valoda CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light teflection Solar energy transmission Solar energy reflection Eiropas Padomes(EP) Marķējums Raksturīgās īpašības Ugunsizturīgs Reaģē ar uguni Ārējās uguns veiktspēja(izolācijas spēja) Ložu necaurlaidīgs Izturīgs pret eksploziju Izturīgs pret ielaušanos un huligānismu Izturīgs pret krītošu ķermeņu triecienu Izturīgs pret krasām temperatūras svārstībām un temperatūras atšķirībām Iztur vēja, sniega, pastāvīgas un īslaicīgas(pēkšņas) slodzes. Tiešu aviācijas trokšņu izolācija Termiskās īpašības Caurstarojums Siltumcaurlaidības koeficienta U vērtība. Starojuma īpašības Gaismas caurlaidība Gaismas atstarošana Saules enerģijas caurlaidība Saules enerģijas atstarošana Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Nātrija-kalcija silikātu float stikls Nātrija-kalcija silikātu dekoratīvais stikls Nātrija-kalcija silikātu dekoratīvais stikls ar stiegrojumu Pārklāts stikls Termiski rūdīts nātrija-kalcija silikātu drošības stikls Karstumā testēts (Heat-Soak test) termiski rūdīts nātrija-kalcija silikātu drošības stikls Termiski stiprināts nātrija-kalcija silikātu drošības stikls Stikla pakete Laminēts stikls un laminēts aizsargstikls Ugunsizturīgs stikls 478
479 English lietuviu kalba CE Marking CE žymejimas Characteristics Charakteristikos Resistance to fire Atsparumas ugniai Reaction to fire Sąveika su ugnimi External fire performance Išorinės ugnies charakteristikos Bullet resistance Atsparumas šūviams Explosion resistance Atsparumas sprogimams Burglar resistance Atsparumas įsilaužimams Pendulum body impact resistance Atsparumas kintančiam kūnų poveikiui Resistance against sudden temperature changes and temperature differentials Atsparumas staigiam temperatūrų pasikeitimui ir temperatūrų skirtumams Wind, snow, permanent and imposed load resistance Atsparumas vėjo, sniego, pastovioms ir staigioms apkrovoms Direct airborne sound insulation Oru sklindančio garso izoliacija Thermal properties Šiluminės savybės Emissivity Emisija U-value U-reikšmė, šiluminio pralaidumo koeficientas Radiation properties Radiacinės savybės Light transmission Šviesos pralaidumas Light reflection Šviesos atspindėjimas Solar energy transmission Saulės energijos perdavimas Solar energy reflection Saulės energijos atspindėjimas Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Plokščias kalcio natrio silikatinis stiklas Raštuotas kalcio natrio silikatinis stiklas Armuotas raštuotas kalcio natrio silikatinis stiklas Stiklas su danga Termiškai grūdintas kalcio natrio silikatinis stiklas Termiškai grūdintas ir karščiu (HST) testuotas sagus kalcio natrio silikatinis stiklas Karščiu sustiprintas kalcio natrio silikatinis stiklas Stiklo paketas Laminuotas stiklas ir saugus laminuotas stiklas Ugniai atsparus stiklas 479
480 English Magyar CE Marking CE-jelölés Characteristics tulajdonságok Resistance to fire tűzállóság Reaction to fire éghetőség External fire performance jellemzők kültéri tűz esetén Bullet resistance golyóállóság Explosion resistance robbanás-ellenállás Burglar resistance betörés- ellenállás Pendulum body impact resistance ingaütés-ellenás Resistance against sudden temperature changes and temperature differentials ellenállás a hirtelen hőmérsékletváltozásnak és nagy mértékű hőmérésklet különbségnek Wind, snow, permanent and imposed load resistance szél, hó, folytonos és ráhelyezett teherbírás Direct airborne sound insulation direkt léghanggátlás Thermal properties thermikus tulajdonságok Emissivity emisszivitás U-value U-érték Radiation properties sugárzás Light transmission fényáteresztés Light teflection fényvisszaverés Solar energy transmission energia áteresztés Solar energy reflection energia visszaverés g-value g-érték Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass float üveg katedrál üveg drót üveg bevonatos üveg edzett üveg "heat-soak" teszttel edzett biztonsági üveg előfeszített üveg hőszigetelő üveg ragasztott és ragasztott biztonsági üveg tűzálló üveg 480
481 English Nederlands CE Marking CE markering Characteristics Karakteristieken Resistance to fire Brandwering Reaction to fire Reactie op brand External fire performance Gedrag ten opzichte van uitwendige vuurhaard Bullet resistance Kogelwering Explosion resistance Explosiewering Burglar resistance Inbraakwering Pendulum body impact resistance Slingerproefweerstand Resistance against sudden temperature changes and temperature differentials Weerstand tegen plotse temperatuursverandering en temperatuursverschillen Wind, snow, permanent and imposed load resistance Weerstand tegen wind-, sneeuw- en permanente belasting Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light reflection Solar energy transmission Solar energy reflection Directe luchtgeluidisolatie Thermische eigenschappen Emissiviteit U-waarde Stralingseigenschappen Lichttransmissie Lichtreflectie Zontoetreding Zonreflectie Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Basisnatronkalk floatglas Basisnatronkalk figuurglas Basisnatronkalk figuurdraadglas Gecoat glas Thermisch gehard natronkalkveiligheidsglas Thermisch gehard natronkalk veiligheidsglas met heat soak test Thermisch versterkt natronkalkglas Isolerend dubbel glas (IDG) Gelaagd glas en gelaagd veiligheidsglas Brandwerend glas 481
482 English Norks CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light reflection Solar energy transmission Solar energy reflection CE merking Betegnende Brannhemmende Reaksjon mot brann Ekstern brannmotstand Skuddhemmende Eksplosjonshemmende Innbruddshemmende Pendultest(personsikkerhet) Motstand mot plutselige tempratursvingninger og tempraturforskjeller Vind-,Snø- og varig ilagt belastningsmotstand Direkte luftbåren lydisolasjon Isoleringsegenskaper Emissivitet U-Verdi Strålingsegenskaper Sollys transmisjon Sollys refleksjon Solenergi transmisjon Solenergi refleksjon Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Kalk-soda-silikat floatglass Kalk-soda-silikat ornament glass Kalk-soda-silikat ornament trådglass Belagt glass Termisk herdet glass Heat soaked termisk herdet kalk-soda-silikat glass Varmeforsterket glass Isoler glass Laminert glass og laminert sikkerhetsglass Brannbeskyttende glass 482
483 English polski CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light reflection Solar energy transmission Solar energy reflection Oznakowanie CE Właściwości Odporność na ogień Reakcja na ogień Zachowanie w przypadku pożaru Odporność na uderzenie pocisku Odporność na siłę eksplozji Odporność na włamanie Odporność na uderzenie wahadłem Odpoprność na nagłe zmiany temperatury oraz różnice temperatur Odporność na siłę wiatru, napór śniegu oraz stałe i przyłożone obciążenia Izolacja akustyczna Właściwości termiczne Emisyjność Współczynnik U Właściwości w zakresie promieniowania Przepuszczalność światła Odbicie światła Przepuszczalność energii promieniowania słonecznego Odbicie energii promieniowania słonecznego Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Podstawowe wyroby ze szkła float sodowo-wapniowo-krzemianowego Podstawowe wyroby ze szkła wzorzystego walcowanego sodowo-wapniowo-krzemianowego Podstawowe wyroby ze szkła wzorzystego zbrojonego sodowo-wapniowo-krzemianowego Szkło powlekane Termicznie hartowane bezpieczne szkło sodowo-wapniowo-krzemianowe Wygrzewane termicznie hartowane bezpieczne szkło sodowo-wapniowo-krzemianowe Cieplnie wzmocnione szkło sodowo-wapniowo-krzemianowe Szyby zespolone izolacyjne Szkło warstwowe i bezpieczne szkło warstwowe Szkło ognioodporne 48
484 English Romanian CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light reflection Solar energy transmission Solar energy reflection marcaj CE caracteristici rezistenta la foc reactia la foc comportare la un foc exterior rezistenta la glont rezistenta la explozie rezistenta la efractie rezistenta la impactul cu un pendul rezistenta la variatii bruste de temperatura si la diferente de temperatura rezistenta la incarcari datorate vantului si zapezii si la incarcari permanente si impuse atenuare fonica - izolare la zgomot aerian proprietati termice emisivitate valoare U proprietati de radiatie transmisia luminii reflexia luminii transmisia energiei solare reflexia energiei solare Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass sticla float calco-sodica sticla ornament calco-sodica sticla armata calco-sodica sticla cu pelicula sticla calco-sodica,de siguranta, securizata sticla calco-sodica, de siguranta, securizata, cu efectuarea testului de depistare a sulfurii de nichel sticla calco-sodica, calita (semi-securizata) vitraj izolant sticla stratificata, sticla stratificata de siguranta sticla rezistenta la foc 484
485 English português CE Marking Characteristics Resistance to fire Resistência ao fogo Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties U-value Light transmission Light reflection Solar energy transmission Solar energy reflection Reacção ao fogo Prestações de comportamento frente ao fogo exterior Resistência a bala Resistência a explosão Resistência a agressão Resistência ao impacto do corpo pendular Resistência as variações bruscas de temperatura e diferenciais termicos Resistência á pressão do vento e neve e ás cargas permanentes impostas Isolamento ao ruído aéreo directo Propriedades térmicas Coeficiente Ug Transmissão luminosa Reflexão luminosa Transmissão da energia solar Reflexão da energia solar Basic soda lime silicate float glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Vidro á base de silico-sódico calcio Vidro de capa Vidro de segurança temperado Vidro de segurança temperado e com tratamento Heat Soak Test Vidro termo-endurecido Unidade de vidro duplo Vidro laminado e vidro laminado de segurança 485
486 English slovenčina CE Marking Označenie CE Characteristics Vlastnosti Resistance to fire Odolnosť voči ohňu Reaction to fire Reakcia na oheň External fire performance Správanie sa voči vonkajšiemu ohňu Bullet resistance Nepriestrelnosť Explosion resistance Odolnosť voči výbuchu Burglar resistance Odolnosť voči vlámaniu Pendulum body impact resistance Odolnosť voči nárazu kyvadla Resistance against sudden temperature changes and temperature differentials Odolnosť voči náhlym teplotným zmenám a teplotným rozdielom Wind, snow, permanent and imposed load resistance Odolnosť voči vetru, snehu a trvalému a náhodilému zaťaženiu Direct airborne sound insulation Priama vzduchová nepriezvučnosť Thermal properties Tepelné vlastnosti Emissivity Emisivita U-value K-hodnota Radiation properties Vlastnosti ohľadom žiarenia Light transmission Prestup svetla Light reflection Odraz svetla Solar energy transmission Prestup slnečného žiarenia Solar energy reflection Odraz slnečného žiarenia Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Základné plavené sodnovápenatokremičité sklo Základné sodnovápenatokremičité vzorované sklo Základné sodnovápenatokremičité vzorované sklo s drôtenou vložkou Sklo s povlakom Tepelne tvrdené sodnovápenatokremičité bezpečnostné sklo Prehrievané tepelne tvrdené sodnovápenatokremičité bezpečnostné sklo Tepelne spevnené sodnovápenatokremičité sklo Jednotky izolačného skla Laminované sklo a laminované bezpečnostné sklo Protipožiarne sklo 486
487 English slovenščina CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light teflection Solar energy transmission Solar energy reflection g-value CE označevanje Lastnosti Ognjeeodpornost Obnašanje med požarom Obnašanje med zunanjim požarom Odpornost pred streli Odpornost pred eksplozijo Odpornost na vlome Odpornost na preiskus z nihalom Odpornost na nenadne temperaturne spremembe in na razlike v temperaturah Odpornost na nenadne temperaturne spremembe in na razlike v temperaturah Direktna zvočna izolirnost Toplotne lastnosti Sevanje U - vrednost Sevalno tehnične lastnosti Prepustnost svetlobe Odbojnost svetlobe Prepustnost energije odbojnost energije g-vrednost Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Ravno steklo iz natrijsilikatnega stekla Vzorčasto steklo iz natrijsilikatnega stekla Žično vzorčasto steklo iz natrijsilikatnega stekla Steklo z nanosi Kaljeno steklo iz natrij-kalcij silikatnega stekla Kaljeno steklo s toplotnim preiskusom iz natrij-kalcij silikatnega stekla Toplotno utrjeno steklo iz natrij-kalcij silikatnega stekla Izolacijski stekleni elementi Lepljeno in varnostno lepljeno steklo Ognjeodporno steklo za uporabo v gradbeništvu 487
488 English suomi CE Marking CE-merkintä Characteristics Erityistuntomerkit Resistance to fire Palon kestävä Reaction to fire Paloa pidättävä External fire performance Paloa hidastava Bullet resistance Luodinuojaus Explosion resistance Räjähdyksensuojaus Burglar resistance Murronsuojaus Pendulum body impact resistance Suojaus henkilön törmäystä vastaan Resistance against sudden temperature changes and temperature differentials Suojaus äkillistä lämpötilanmuutosta ja lämpötilagradientteja vastaan Wind, snow, permanent and imposed load resistance Suojaus tuulikuormaa, lumikuormaa, pysyvää kuormaa jahyötyuormaa vastaan Direct airborne sound insulation Suoran ilmaääneen eristys Thermal properties Lämmöneristys Emissivity Emissiivisyys U-value U-arvo Radiation properties Säteilyn suojaus Light transmission Valonläpäisy Light reflection Valonheijastus Solar energy transmission Auringon lämpösäteilyn kokonaisläpäisy Solar energy reflection Auringon lämpösäteilyn heijastus Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Natronkalkkisilikaattitasolasi Natronkalkkisilikaatti koristelasi Kuvioitu natronkalkkisilikaattirautalankalasi Pinnoitelasi Lämpökarkaistu natronkalkkisilikaattiturvalasi Heat soak testattu karkaistu natronkalkkisilikaattiturvalasi Lämpölujitettu natronkalkkisilikaattiturvalasi Eristyslasiyksiköt Laminoitu lasi ja laminoitu turvalasi Palonsuojalasi 488
489 English svenska CE Marking Characteristics Resistance to fire Reaction to fire External fire performance Bullet resistance Explosion resistance Burglar resistance Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance Direct airborne sound insulation Thermal properties Emissivity U-value Radiation properties Light transmission Light reflection Solar energy transmission Solar energy reflection CE-märkning Karaktäristik Motstånd mot brand Reaktion vid brand Externt brandmotstånd Motstånd mot projektiler Säkerhet vid explosion Motstånd mot inbrott Pendelprov (personsäkerhet) Motstånd mot plötsliga temperatursvängningar och temperaturgradienter Vind-, snö-, permanent/tillfällig belastning. Ljudisolering Värmeisolering Emissivitet U-värde Strålningsegenskaper Ljustransmission Ljusreflektion Solenergi transmission Solenergi reflektion Basic soda lime silicate float glass Basic soda lime silicate patterned glass Basic soda lime silicate wired patterned glass Coated glass Thermally toughened soda lime silicate safety glass Heat soaked Thermally toughened soda lime silicate safety glass Heat strengthened soda lime silicate glass Insulating glass units Laminated glass and laminated safety glass Fire resistant glass Kalk-sodasilikatglas,floatglas Kalk-sodasilikatglas, mönstrat glas Kalk-sodasilikatglas, mönstrat trådglas Belagt glas Termiskt härdat glas Heat soak testat termiskt härdat kalk-sodasilikatglas Värmeförstärkt kalk-sodasilikatglas Isolerglas Suédois Brandskyddsglas 489
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Thermally Toughened Heat and Solar Control Glass 1 (C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics
Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5
4-12 - 33.1, Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1(C)3-12 - 2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 2,8 W / (m 2 K) Light transmission and reflection
Technical information
Technical information Toughened and laminated safety glasses GLASS UNLIMITED Sommaire 1. INTRODUCTION 1. Introduction 3 2. Laminated glass 4 3. Thermally toughened glass 6 4. European classification standards
II. ALL ABOUT GLASS. www.yourglass.com
II. ALL ABOUT GLASS 1 Glass products 16 1.1 Composition 17 1.2 Properties 18 1.3 Glass products 19 2 Properties and functions 30 2.1 Introduction 31 2.2 Radiation, light and colour 32 2.3 Thermal insulation
Glass unlimited YOURGLASS POCKET
Glass unlimited YOURGLASS POCKET SUMMARY Page Product and brand index 4 I. THE AGC GROUP 1 Introduction 10 2 Contacts 15 3 Caring about the environment 20 II. ALL ABOUT GLASS 1 Introduction 26 1.1 Nomenclature
EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)
4 (# 2) - 12-33.1, Heat Control Glass (Low-E #2) + Argon (90%) + Pendulum body impact resistance - 12-2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4-12 - 4 (#3), Thermally Toughened Helio Blue + Dry Air (100%) + 1(C)3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,58/0,/0,10 Solar energy characteristics
Solar control right for you!
Solar control right for you! Landesbank Baden-Württemberg, Stuttgart SGG COOL-LITE ST 0 SGG COOL-LITE ST Solar control right for you! D e s c r i p t i o n SGG COOL-LITE ST is a solar control glass manufactured
MIROX 3G ENVIRONMENTALLY- FRIENDLY MIRROR
MIROX 3G ENVIRONMENTALLY- FRIENDLY MIRROR One step closer to perfection MIROX 3G is a unique product and AGC Flat Glass Europe holds the exclusive patent for the manufacturing process. It is the third
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
6 (#1) - 12-4 (#3), Thermally Toughened Tentesol T Blue #1 + Dry 1(C)2-12 - 6-12 - 4 32 (-2; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,34/0,34/0,18 Solar energy characteristics
Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5
4 (#2) - 12-4, Thermally Toughened ISS114 #2 + Dry Air (%100) + Clear 1(C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 2,6 W / (m 2 K) Light transmission and reflection 0,14/0,34/0,37 Solar energy
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics
EN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Argon (90%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics
Activities. but I will require that groups present research papers
CS-498 Signals AI Themes Much of AI occurs at the signal level Processing data and making inferences rather than logical reasoning Areas such as vision, speech, NLP, robotics methods bleed into other areas
iku windows the intelligent self cleaning window AUTOMATIC system
iku windows is a aluminium sliding window system with two rails and double thermal breakage. By adding the iku box underneath the window sill it becomes an intelligent window. Functions Automatic opening
GUIDELINES FOR TRANSLATING THE EUROPASS CERTIFICATE SUPPLEMENT INTRODUCTION GENERAL RECOMMENDATIONS
GUIDELINES FOR TRANSLATING THE EUROPASS CERTIFICATE SUPPLEMENT INTRODUCTION PURPOSE OF THE EUROPASS CERTIFICATE SUPPLEMENT The Europass certificate supplement (see examples) is not a substitute for the
TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic
- TECHNISCHE FICHE - Chat Board: Classic Classic is a magnetic glass- and writing board for use in modern offices and private homes. CHATBOARD Classic is Danish Design - made in Denmark. Classic is a glass
Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS
Heat-treated Heat-treated Glass Glass Heat-treated Glass Heat-treated Heat-treated Glass Glass REFLECTIVE GLASS LAMINATED GLASS TEMPERED GLASS FLOAT GLASS MIRRORS LOW-E GLASS SUNGUARD PATTERNED GLASS HORTICULTURAL
CrossLoop Help. What would you like to do? Joining A Session
1 of 13 10/10/2007 13:14 "This is outstanding. I can finally connect to other computers without having them forward any ports!" Home Download How It Works FAQs About Help CrossLoop > Help CrossLoop Help
The Daikin Configurator software is intended to be used in combination with the EKPCCAB* USB cable.
Daikin Configurator v2.x.x 1. Introduction The Daikin Configurator software is intended to be used in combination with the EKPCCAB* USB cable. Information: The latest available Daikin Configurator software
Pilkington Activ self-cleaning glass. The clear choice for your conservatory.
Self-cleaning Pilkington Activ self-cleaning glass. The clear choice for your conservatory. Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories
Classification of reaction to fire of glass products Recommendation from Glass for Europe
Classification of reaction to fire of glass products Recommendation from Glass for Europe April 2015 Glass for use in buildings and construction works shall declare a reaction to fire performance in their
TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass
Data Sheet Pilkington Toughened Safety Glass Introduction Pilkington has manufactured and marketed toughened glass for over 60 years. Its properties and performance have been proven in countless applications,
Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.
Pilkington Activ The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Thermal insulation. When it comes to conservatories, we think
Important Notes Color
Important Notes Color Introduction A definition for color (MPI Glossary) The selective reflection of light waves in the visible spectrum. Materials that show specific absorption of light will appear the
Solar Energy: The Power of the Sun by Kelly Hashway
We all know the sun is important. It provides for plants, animals, and people here on Earth. But how does the sun do that? It s the sun s energy that makes life on our planet possible. Energy from the
Exterior glass solutions
Exterior glass solutions SGG Reflectasol SGG Antelio Plus SGG Cool-Lite SGG Planitherm SGG Evo SGG Evolite SGG Nano SGG Nanosilver SGG Envision The future of habitat. Since 1665. NEUTRALS Light Gold Reflectasol
Testing Rules for Thermal Conductivity October 2015
Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity (October 2015) 1 Normative references (to be inserted as additional chapter in the Testing Rules for Panels) 1.
Pilkington Activ self-cleaning glass. The clear choice for your conservatory.
Pilkington Activ self-cleaning glass. The clear choice for your conservatory. The Pilkington Activ Range Self-cleaning and solar control glass for conservatories and orangeries. Conservatories bringing
Elenco concessioni vetri stratificati (per le descrizioni complete dei modelli ed estensioni a loro eventuali varianti vedere certificato)
Azienda Città Prov. Modello N Licenza Data rilascio Saint Gobain Glass Itlaia Pisa PI SGG STADIP 33 PLUS VS001 25/03/2002 in vigore Saint Gobain Glass Itlaia Pisa PI SGG STADIP 44 PLUS VS001 25/03/2002
GET YOUR START MENU BACK IN MICROSOFT WINDOWS SERVER 2012
Products To make your life better Simple to Install Easy, non-technical setup. GET YOUR START MENU BACK IN MICROSOFT WINDOWS SERVER 2012 Easy to Use The start menu design is familiar and comfortable to
DOMUS & ALDUS THE WINDOW CONCEPT WITH A STUNNINGLY MODERN APPEARANCE
DOMUS & ALDUS THE WINDOW CONCEPT WITH A STUNNINGLY MODERN APPEARANCE MODERN DESIGN DOMUS & ALDUS 2 3 ALDUS & DOMUS PRODUCT DETAILS 1 2 3 Option of glazing bar Architectural designed handle Option of trickle
DOW CORNING SENEFFE (Belgium) DOW CORNING GmbH WIESBADEN (Germany) This version replaces ETA 03/0003 valid from 2008-04-10 until 2013-04-09
European Technical Approval ETA-03/0003 Trade name: Holder of the approval: Website: Generic type and use of construction product(s): DOW CORNING 3362 AND 3362 HD BLACK GREY WHITE DOW CORNING Parc Industriel
Industry Insulation. Insulation Solutions for Industry Applications. New CE marking and Isover TECH product range
Industry Insulation Insulation Solutions for Industry Applications New CE marking and Isover TECH product range Introduction dbdg.de Saint-Gobain Group For more than three centuries, Saint- Gobain has
HD36. Bright super-sized images any time of day. Bright vivid colours 3,000 ANSI Lumens. Dynamic black technology - 30,000:1 contrast ratio
HD36 Bright super-sized images any time of day Bright vivid colours 3,000 ANSI Lumens Dynamic black technology - 30,000:1 contrast ratio Full HD 1080p image quality Easy connectivity - HDMI and DVI and
What is Solar Control?
A better environment inside and out. Solar, Safety and Security Window Films: Tech Bulletin Understanding Solar Performance Solar Gard solar control window films use advanced technology to benefit consumers
Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.
Self-Cleaning The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories. Conservatories bringing the outside in. Pilkington Activ has made
Lindab Coverline TM. Lindab Tile Effect Roofing. Make a lasting impression
Lindab Coverline TM Lindab Tile Effect Roofing Make a lasting impression Create your own effect Lindab s tile effect roofing is a strong, elegant steel sheet roof that looks great on new houses and blends
Artile. Italian tradition in a range of colors
Artile Italian tradition in a range of colors Artile An Italian Company In the Negev desert Artile manufactures robust and refined, environmentally friendly and long lasting clay roofing tiles. The Italian
WORKING DOCUMENT FOR SCC CONSULTATION CONSTRUCT09/874 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL
WORKING DOCUMENT FOR SCC CONSULTATION CONSTRUCT09/874 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL New Approach Industries, Tourism and CSR Construction, Pressure Equipment, Metrology
SELECTIVE GLAZING FOR SUN CONTROL
SUN CONTROL GLAZING SELECTIVE GLAZING FOR SUN CONTROL Sun Factor 1st level performance for direct solar energy Solar energy control Solar control coating Only if the glass is exposed to sun rays! 2nd level
PRODUCT SPECIFICATIONS
LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,
List of materials (permanent storage)
0,75 x 1250 25µ Pol. RAL 1000 Green beige 0,75 x 1250 25µ Pol. RAL 1002 Sand yellow 0,75 x 1250 25µ Pol. RAL 1003 Signal yellow 0,75 x 1250 25µ Pol. RAL 1004 Golden yellow 0,75 x 1250 25µ Pol. RAL 1011
SCHOTT PYRANOVA Planline System
Schott_050_Pyranova_E_RZ.fh8.07.005 0:50 Uhr Seite HOME T E C H The Planline system The patented glass fixing method is a clear multi- is based on a fire resistant double glazed allows quick and easy replacement
ACRYLIC SHEET & BLOCKS. New Catalogue. issued in May 2012
New Catalogue issued in May 2012 2 Standard, Full batches or Mini batches? Altuglas International always make an assessment of the best solution. If our standard offer does not meet your requirements,
The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows
by The Industry s Most Advanced Sun-Sensing, Adaptive-Tinting Technology For Dynamic Windows In Alliance with OCCUPANT COMFORT All of the windows above have the same exterior tint of glass. Why such a
STANDING SEAM METAL ROOFING PANELS
STANDING SEAM METAL ROOFING PANELS Roof it for the last time. ENERGY EFFICIENCY WITH STYLE & DURABILITY METAL ROOFING FOR RESIDENTIAL AND COMMERCIAL APPLICATIONS. Featuring the TITAN Cool Roof Reflective
UNLIMITED VARIETY OF CREATIVE SHEET MATERIAL.
UNLIMITED VARIETY OF CREATIVE SHEET MATERIAL. MADE IN SWITZERLAND Airex AG was founded in 1956 and pioneers with its innovations in the field of foamed plastic materials. Apart from manufacturing technical
Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
3M Commercial Graphics. Colour Card Reference Guide. Scotchcal. Opaque Graphic Film. Series 100
3M Commercial Graphics Colour Card Reference Guide 3M Scotchcal Opaque Graphic Film Series 100 3M Scotchcal Opaque Graphic Film Series 100 Yellow 100-25 Pantone 1235 C Cadmium Yellow 100-15 Pantone 109
PTC-Resistor Temperature-Sensors MINIKA to DIN 44 081 and DIN 44 082
PTC-Resistor Temperature-Sensors MINIKA to DIN 44 081 and DIN 44 082 General PTC-resistor temperature sensors (also called PTC-resistors or thermistors) are temperatur dependent semiconductor resistors
Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011
1. plan 1) Goal: Assessment and verification of the constancy of performance of the products as described by the manufacturer in his Declaration of Performance through: initial inspection of the manufacturing
Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
Pilkington Reflite Handling and Processing Guidelines Solar Control
Pilkington Reflite Handling and Processing Guidelines Solar Control Pilkington Reflite 1. Product description Pilkington Reflite is a hard, on-line coated, solar control glass, available in a range of
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
Mureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
Europeiskt Tekniskt Godkännande European Technical Approval
SITAC Box 553 SE 371 23 Karlskrona SWEDEN MEMBER OF EOTA Tfn.: +46-(0)10-516 63 00 Fax: +46-(0)455-206 88 E-mail: [email protected] Europeiskt Tekniskt Godkännande European Technical Approval ETA-11/0380 Handelsnamn
INFORMATION REGARDING GLASS TYPES AND PROPERTIES
INFORMATION REGARDING GLASS TYPES AND PROPERTIES 1. Float Glass Float Glass is annealed glass processed by combining all ingredients and heating them till molten. This molten glass is then poured over
The Peak of Protection
FUTURE ROOF The Peak of Protection Our Future is Your Satisfaction E l e g a n t Imagine the look of heavy wood shake without all the problems associated with wood. Future Shake by Future Roof Systems
Solar Energy. Solar Energy range. NSG TEC Pilkington Microwhite Pilkington Optiwhite Pilkington Sunplus
Solar Energy Solar Energy range NSG TEC Pilkington Microwhite Pilkington Optiwhite Pilkington Sunplus Moving from hydrocarbon dependency to renewable energy The use of solar energy glass and the NSG Group
Nordic quality steel with the widest color range
Nordic quality steel with the widest color range Nordic quality steel with the widest color range Since the merger between SSAB and Ruukki in 2014, the best technology and experience from both companies
usb flash drives with logo delivery within 3 days
usb flash drives with logo delivery within 3 days 2015 QUALITY We do our best to provide top quality products. We work with proven suppliers and carefully select our components. In addition, to make sure
The Warm Edge for insulating glass
The Warm Edge for insulating glass 1. 3. SGGSWISSPACER 2. 4. The best product on the market by quite an edge Energy saving Lower heating costs through better insulation: the thermally improved spacer SGG
Residential Steel Roofing
Agway Metals Inc. 170 Delta Park Blvd Brampton, ON L6T 5T6 1.800.268.2083 97 Thames Road E Exeter, ON N0M 1S3 1.800.265.7070 agwaymetals.com MEMBER Residential Steel Roofing A LIFETIME OF BEAUTY AND VALUE,
Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps
Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps The Twin EL series has two reflectors and an adjustable lampholder making it possible to have inversely proportional light distribution
Unbeatable energy efficient glass curtain wall system
Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics
CHOOSE THE RIGHT DOOR FOR YOUR HOME
DOORS INSPIRATION 1 CHOOSE THE RIGHT DOOR FOR YOUR HOME The door to your house is the gateway to your home. Your choice of entrance door and the way it looks influences your home s architectural expression.
Standard Architecture Color Offerings
Page 1 of 9 COLORWELD 500 FINISHES Standard Architecture Color Offerings SERIES ONE Paint Category Coil Width 4mm PE FG Panels 4mm FR Bone White Colorweld 500 50 & 62 62 x146, Brite Red Colorweld 500 50
RAL 1002 Sand yellow. RAL 1007 Daffodil yellow. RAL 1015 Lighti vory. RAL 1020 Olive yellow. RAL 1027 Curry yellow. RAL 1035 Pearl Beige
RAL 1000 Green beige RAL 1001 Beige RAL 1002 Sand yellow RAL 1003 Signal yellow RAL 1004 Golden yellow RAL 1005 Honey yellow RAL 1006 Maize yellow RAL 1007 Daffodil yellow RAL 1011 Brown beige RAL 1012
CertainTeed. Impact Resistant. Shingles. Shown in Landmark IR Weathered Wood. Est.1665
CertainTeed Impact Resistant Shingles Shown in Landmark IR Weathered Wood Est.1665 Shown in Presidential Shake IR Autumn Blend You know it, when you see it. It s not just a roof. It s a CertainTeed roof.
Humbrol conversions to other paint manufacturers
Humbrol conversions to other paint manufacturers Code Chip Colour Name Category Revell Lifecolor Vallejo Tamiya Hobby Color1 Mr. Color2 Model Masters Games Workshop Chip 1 Primer Matt 2 Emerald Gloss 61
endurance SOLID CORE COMPOSITE DOORS
endurance SOLID CORE COMPOSITE DOORS The Endurance Range - the peak of security In today s world of adverse weather conditions and ever increasing crime figures, there is a growing need for people to feel
Omnisports Vinyl solutions
Indoor Sports Vinyl solutions Our vinyl solutions p. 368-377 Badminton kit p. 376 Table Tennis solution p. 377 The ideal multi-purpose surface is a multi-purpose vinyl sports surface that has been designed
Il potere tra le tue mani
Il potere tra le tue mani Sarda Elaborazione Dati s.r.l. Via Is Corrias 14-16 Cagliari Tel. 070 542032-070 8648169 Cell. 346 3551428-3490514207 www.sardaelaborazionedati.com Partita IVA n 03360210920 NEW
Community herbal monograph on Commiphora molmol Engler, gummi-resina
12 July 2011 EMA/HMPC/96911/2010 Committee on Herbal Medicinal Products (HMPC) Community herbal monograph on Commiphora molmol Engler, gummi-resina Final Discussion in Working Party on Community monographs
screens that fit you COLLECTION 2012-2015
screens that fit you COLLECTION 2012-2015 D interior exterior OF = 5% reflect sunlight outdoors www.copaco.be 8 OF = 5% reflect sunlight outdoors Colours & references / 0202 white white / 0802 linen white
Fire Resistant Systems
Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant
Impact-Resistant Windows and Sliding Glass Doors
Impact-Resistant Windows and Sliding Glass Doors Make Your Home A SafeHarbor. SafeHarbor Impact-Resistant Windows and Sliding Glass Doors are designed to look like traditional windows and doors, but they
WOODEN WINDOWS CATALOGUE. www.bako-okna.pl
CATALOGUE MATERIAL Dear Sirs, Pine - preferably selected raw material for production of windows. Pine has a bright fresh colour, durability, excellent resistance to weather conditions and excellent thermal
Spandrel Glass Types and Recommendations
Spandrel Glass Types and Recommendations Introduction PPG has long offered recommendations regarding alternatives for glass spandrel applications. Over the years these recommendations were included in
Low Bay High Bay. Lighting. Industrial Series. The best lighting level for better working performance.
Low Bay High Bay The best lighting level for better working performance. Industrial Series Lighting INDOOR LIGHTING Low Bay & High Bay Luminaries for interiors with low, medium, and high ceilings such
ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!
Secure and efficient IT room solutions Composite Panel Systems Compared Panel Systems are not all the same! When it comes to accommodating critical IT systems, the first issue to look at is the environment
Community herbal monograph on Lavandula angustifolia Miller, aetheroleum
27 March 2012 EMA/HMPC/143181/2010 Committee on Herbal Medicinal Products (HMPC) Community herbal monograph on Lavandula angustifolia Miller, aetheroleum Final Discussion in Working Party on Community
T H E P E N C O L L E C T I O N
T H E P E N C O L L E C T I O N 2 Banda Baron Baron 03 Ice Bio-S! Caribia 33 Carlo Carolina 18 Carolina Frost 19 Fox 31 Gift Boxes 21 Hallo Grip Hallo Grip Frost Happy 23 24 25 29 34 12 13 31 28 22 23
Superconcrete. your green flooring choice www.klindex.it
Superconcrete your green flooring choice www.klindex.it Transform your concrete floor! The purpose is to transform the ordinary concrete floor into a floor which is remarkably shiny and dust free. Esthetically
A pro s guide to photo prints on Alu-dibond
A pro s guide to photo prints on Alu-dibond The way for professional photographers to get the best results out of Alu-dibond XXLPIX 2013 For professional photographers only Table of content Alu-Dibond...3
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
Simplify your palette
Simplify your palette ou can create most any spectrum color with a simple six color palette. And, an infinity of tones and shades you ll make by mixing grays and black with your colors... plus color tints
BRILLIANT, LONG LASTING PRINTS ON GLOSSY OR LUSTER FINISH PHOTOGRAPHIC PAPER. $1.49 $.95 640X480
DIGITAL MEDIA TO PRINT BRILLIANT, LONG LASTING PRINTS ON GLOSSY OR LUSTER FINISH PHOTOGRAPHIC PAPER. WALLET (PER PAIR, SAME IMAGE) OF SAME IMAGE RECOMMENDED MINIMUM FILE SIZE $1.49 $.95 640X480 3½X5 $.69
BUILDING INSTRUCTIONS
etap2hw 38 mm I2C to LCD Interface BUILDING INSTRUCTIONS October 2013 P. Verbruggen Rev 1.01 15-Oct-13 Page 1 Table of Contents Chapter 1 General Information 1.1 ESD Precautions 1.2 Further Supplies 1.3
Lucent. www.bestsigns.com
Lucent www.bestsigns.com Lucent Bringing natural light into signage Lucent is a preferred alternative to glass and traditional ADA plaque signs because of its optical clarity, durability and design flexibility.
BAGS & WRAPPING. Bags & Wrapping - Great range, value & custom possibilities
TEL: 08 8223 1461 [email protected] FAX: 08 8223 1482 www.displayline.com.au Bags & Wrapping - Great range, value & custom possibilities Paper Bags 337 Plastic Bags 342 Custom Bags 343 Tissue Paper
first base 3 BUMP PROTECTION
first base 3 BUMP PROTECTION First Base A REVOLUTION IN BUMP PROTECTION. In 1997, following extensive customer research, industry pioneers Scott Safety introduced the original baseball style bump protection
Glass partitions SFB 3074
Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use
Shunt lock function 3066
Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning
Community herbal monograph on Arnica montana L., flos
6 May 2014 EMA/HMPC/198793/2012 Committee on Herbal Medicinal Products (HMPC) Final Discussion in Working Party on Community monographs and Community March 2012 list (MLWP) May 2012 November 2012 March
