CT3200 Programmable Thermostat
|
|
|
- Grant Dean
- 10 years ago
- Views:
Transcription
1 CT3200 Programmable Thermostat Welcome to the world of comfort and energy savings with your new Honeywell Programmable Thermostat. Your new thermostat will automatically control the temperature in your home, keeping you comfortable while saving energy. OWNER S GUIDE Weekday/Weekend (5-day/2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model CT3200 Table of Contents Installation... 2 Programming Operation Frequently Asked Questions Customer Assistance Limited Warranty U.S. Registered Trademark Copyright 2003 Honeywell International Inc. All Rights Reserved
2 MERCURY NOTICE If you are removing an old thermostat that contains mercury in a sealed tube (Fig. 1), do not place the old thermostat in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of the old thermostat. MERCURY SWITCH Fig. 1. M3701 INSTALLATION Verify You Have Correct Thermostat Make sure that the CT3200 is the correct thermostat for your heating/cooling system. Read the compatibility chart below to determine which system you have. If your system is not compatible with the CT3200, the table recommends an alternate Honeywell model. If you are unsure what type of thermostat is right for your system, visit us on the Web at or call Honeywell Customer Care at Heating/Cooling System Conventional Single stage systems that include warm air furnaces and hot water. Electric Baseboard Electric-powered heating strips located just above the floor, usually 120 to 240 volts. Compatible with CT3200? Yes Alternate Model No CT1950 for 240 volts
3 Heating/Cooling System Steam A steam boiler with radiator heat. Heat Pump Heating and cooling are produced from the same outdoor unit (compressor) with no auxiliary or backup heat. Multistage Heat Pump Heating and cooling are produced from the same outdoor unit (compressor) with auxiliary or backup heat. Multistage Conventional A heating or cooling system with more than one stage. Compatible with CT3200? No No No No Alternate Model CT3600 CT3600 CT3611 See your contractor Step 1. Prepare for Installation 1. Carefully unpack your new thermostat. Save your receipt and make sure you have the following parts: Thermostat and mounting plate Labels Screws and anchors Installation and Programming Instructions 2. Gather the needed tools and supplies listed below. Required Tools and Supplies Two AA alkaline batteries. Honeywell recommends Energizer batteries. Screwdriver. Hand or power drill with 3/16-inch or 7/32-inch drill bit. Pencil. Optional Tools Wire cutter/stripper or sharp knife. Level. Electrical tape. 3. Make sure that your heating and cooling systems are working properly. If there is a problem with either system, call a heating/air conditioning contractor the problem may persist after you install the new thermostat. IMPORTANT: To avoid damaging the compressor in the air conditioner, do not operate the cooling system when the temperature outdoors is below 50 F (10 C)
4 Step 2. Remove Old Thermostat Fig. 2. a. Turn off power to the heating/cooling system, either at the furnace or at the fuse/circuit breaker panel. b. Remove the cover of your old thermostat (Fig. 2). c. Unscrew and remove the old thermostat s mounting plate from the wall, but do not disconnect the wires. d. Inspect the old thermostat wiring. If wiring meets any of the following conditions, see special wiring instructions section after Step 7. M20140 Fig. 3. The old thermostat is a clock thermostat with wires attached to the C or C1 terminals. The old thermostat has six or more wires, excluding wires attached to C or C1 terminals. The old thermostat has three wires. There are five wires connected to the old thermostat. There are extra wires that are not connected to the old thermostat. e. Using enclosed labels, mark wires with letter of terminal it is attached to on the old thermostat (Fig. 3). Do not label using colors. If labels do not match letters on old thermostat terminals, see wiring cross reference table in Special Wiring Instructions section. M19086 Fig. 4. f. Disconnect the wires from the old thermostat and wrap the WIRES THROUGH wires around a pencil to keep them from falling back into the WALL OPENING wall. NOTE: Remember, if your old thermostat contains mercury, you must recycle it. See Mercury Notice for more recycling information. M Check your progress Your wall should now look like Fig. 4.
5 Step 3. Install Mounting Plate Fig. 5. a. Separate the mounting plate from the thermostat using a coin, as shown in Fig 5. b. Position the mounting plate on the wall. Be sure the mounting plate is flush against the wall and none of the wires are trapped behind it. c. Level the mounting plate and use a pencil to mark the center of the mounting plate screw holes. d. Remove the mounting plate and drill holes at the locations marked. For drywall, drill two 3/16-inch holes. M20139 For plaster or wood, drill two 7/32-inch holes. Fig. 6. e. If installing in drywall, gently tap the anchors (provided) into the drilled holes until they are flush with the wall. f. Reposition the mounting plate over the holes, pull the wires through the wiring opening, and loosely insert the mounting screws into each of the drilled holes or anchors (Fig. 6). g. Make sure the mounting plate is level and tighten the mounting screws. M20129 Fig. 7. Check your progress The mounting plate is now mounted on the wall and should look like Fig. 7. Y Rc G R W M
6 Step 4. Set Thermostat for Your Type of Heating System Fig. 8. DISPLAY F DISPLAY C 3 - ON 3 - OFF THERMOSTAT BACK FUEL SWITCH F E ON OFF ON C HEATING SYSTEM WARM AIR FURNACE HOT WATER OR HIGH EFFICIENCY ELECTRIC FURNACE I M P O R T A DIP SWITCH POSITION 1 - ON 2 - ON F 1 - OFF 2 - ON F 1 - ON 2 - OFF E N T W : Y G W Y G C R R C FUEL SWITCH POSITION R C M20637 IMPORTANT: Setting your thermostat correctly for your type of heating system allows it to maintain accurate temperature control, minimize swings in the temperature of the room, and efficiently run the fan. a. Use the FUEL SWITCH on the back of the thermostat to set your new thermostat for the type of fuel that your heating system uses: F gas or oil, or E electric. NOTE: This setting enables proper fan operation. b. Use DIP switches 1 and 2 on the back of the thermostat to set your new thermostat for your type of heating system. See the Heating System Table on the next page to find the correct settings. NOTE: These DIP switches are factory-set for a warm air, gas, or oil heating system. c. The thermostat is set to display the temperature in degrees Fahrenheit ( F). If you want to display the temperature in degrees Celsius ( C), turn DIP Switch 3 to Off position. d. You can install the batteries and program your thermostat now, or you can wait until the thermostat is mounted on the wall. To install the batteries, see Step 7.To program the thermostat, see the Programming section
7 Heating System Table Type of System DIP Switches 1 and 2 Fuel Switch Warm air, gas, or oil heating system with an efficiency rating under 90%. Use factory setting F (The furnace efficiency rating should be on the furnace.) 1 On; 2 On High-efficiency furnace such as a 90% or greater AFUE (Average Fuel 1 Off; 2 On F Utilization Efficiency) unit Hot water boiler 1 Off; 2 On F Electric furnace 1 On; 2 Off E Step 5. Wire Thermostat Terminals Fig. 9. a. Hold thermostat as shown in Fig. 9. b. Using the labels on the wires, match letter of your old thermostat wire with the corresponding terminal on the back of your new thermostat. G Y R W NOTE: If letters on old thermostat terminals do not match letters on new thermostat terminals, all old wires may not need connecting to new thermostat. See Special Wiring Instructions section. M20125 Fig. 10. c. Loosen terminal screws and slip each wire beneath its matching terminal (Fig 10). d. Securely tighten terminals. 5/16 in. (8 mm) STRIP INSERT STRAIGHT UNDER SCREW HEAD END OF WIRE VISIBLE HERE M
8 Step 6. Mount Thermostat Fig. 11. Fig. 12. e. Align the tabs at the top of the thermostat with the tabs at the top of the mounting plate (Fig. 11). f. Press the lower edge of the case to latch the bottom of the thermostat (Fig. 12) M20130 M
9 Step 7. Install the batteries Fig. 13. M1719C Fig. 14. REMOVING BATTERY DOOR IMPORTANT: Batteries must be installed for programming and operation of the thermostat and heating/cooling system. Honeywell recommends using Energizer batteries. a. Make sure that the System switch is set in the OFF position. b. Using a coin, open the battery door as shown in Fig. 13. c. Install the batteries. Make sure that the positive and negative terminals are oriented correctly as marked inside the battery case. d. Replace the battery door. e. Remove the clear plastic label from the digital display. Check your progress When the batteries are installed correctly, the digital display flashes all entries once, then begins to flash a default time and the current temperature (Fig. 14). The flashing continues until you begin to program the thermostat. You are now ready to program the thermostat. See Programming section. Special Wiring Instructions Clock thermostat with C or C1 terminals A clock thermostat has one or two extra wires attached to the C or C1 terminals that allow the clock to operate. These wires are not used during the installation of your new 3200 Thermostat and must be insulated from each other to avoid damaging your electrical circuit. a. Make sure that power to the heating/cooling system is turned off. b. Locate the wires that are connected to the clock terminals marked C or C1. c. As you disconnect the wires, do not allow these wires to touch. d. Wrap the wires separately, using electrical tape to insulate the wires. e. Place the wires where they do not interfere with the operation of the new thermostat. You will not connect these wires to your 3200 Thermostat. f. Continue with the installation
10 Six or more wires If your old thermostat has six or more wires (excluding clock wires attached to the C or C1 terminals), your heating/ cooling system is most likely a variation of a heat pump or multistage system. Your 3200 Thermostat will NOT work with such systems and should be returned to the place of purchase. See the thermostat compatibility table for information about which programmable thermostat will work with your system. Three thermostat wires If you have three wires for heating only and can operate the fan using the fan ON switch, the 3200 Thermostat will work with your system. Continue the installation procedure. If you have a three-wire heating-only system and cannot operate the fan using the fan ON switch, the 3200 Thermostat will probably NOT work with your system. Contact your heating contractor for installation assistance. Wires that are not connected to old thermostat If there are extra wires that do not connect to your old thermostat, do not label them. You will not connect these wires to your new thermostat. Tape off the wires individually with electrical tape and place them where they will not interfere with the operation of the new thermostat. Continue the installation procedure. Five wires connected to old thermostat JUMPER (FACTORY- INSTALLED). REMOVE IF 5-WIRE SYSTEM Your new thermostat has a factory-installed metal jumper between the R and Rc terminals (Fig. 15). Remove the jumper before wiring the R and Rc terminals. R R c Fig. 15. W Y G M20127 Thermostat C Terminal This thermostat does not use the C wiring terminal
11 Old thermostat terminals that do not match new thermostat terminals Use the table below to wire the new thermostat. Old Thermostat Terminal Connect to New Thermostat Terminal Description R, RH, 4, V R* Power Rc, R Rc* Power for cooling W, W 1, H W Heat Y, Y 1, M Y Cooling G, F G Fan O Do not continue Changeover in cool (O terminal) or changeover in heat (B terminal). B installation You have a single-stage heat pump or zoning system. Select an alternate thermostat model. C, X, B Do not connect Transformer common. W 2, H 2 Y 2 Do not continue installation. Second stage heat (W 2, H 2 ) or second stage cooling (Y 2 ). You have a multistage heating/cooling system. Select an alternate thermostat model. *Remove factory-installed jumper between R and Rc terminals in 5-wire systems
12 PROGRAMMING Faceplate Illustration and Description Set clock/day Set Schedule Fan Auto On Time Ahead Back Descriptions Fig Fan switch Selects automatic fan operation or fan on. 2 Set Schedule Puts the thermostat into programming mode. 9 3 Set Clock/Day Sets the clock and day. SYSTEM ON 10 4 Time Ahead and Back Sets the time ahead and back. TEMPORARY 7 8 AM PM SET MO TU WE TH FR SA SU WAKE LEAVE RETURN SLEEP Temp Warmer Cooler Run Program Hold Temp System Cool Off Heat M Program periods Current program period or period being programmed. 6 Day of the week Current day or day being programmed. 7 Time Current time or program time. 8 Temperature Room temperature or programmed temperature. 9 SYSTEM ON An arrow displays when the heating/ cooling system is running. 10 TEMPORARY An arrow displays when a temporary override is made to the program. 11 Temp Warmer and Cooler Sets the temperature warmer and cooler. 12 Run Program Returns thermostat to normal operating mode 13 Hold Temp Holds a selected temperature. 14 System switch Selects Cool, Off, Heat
13 Step 1. Set Current Time and Day a. Press once. The time is displayed (Fig. 17). Fig. 17. b. Press and hold or until the current time is displayed. c. Press again. Fig. 18. The day is displayed (Fig. 18). d. Press and hold or until the current day is displayed. e. Press once. The current time and day and the current temperature are displayed (Fig. 19). Fig. 19. Step 2. Learn About Programming Features Your 3200 Thermostat allows you to program schedules for both a heating season and a cooling season. During the heating season, you will want to set the normal room temperature higher and the energy-saving temperature lower. The reverse is true during the cooling season the normal room temperature will be lower and the energy-saving temperature higher. For each season, you can set up to four program periods for the weekdays (Monday Friday), and up to two program periods for the weekends (Saturday and Sunday). The program periods are defined in the following table
14 Program Period Description When Available WAKE The time when you get up and get ready to leave your home. You can Weekdays and weekend set the system at a comfortable temperature for this period. LEAVE The time when you are regularly away from home. You can set up an Weekdays only energy-saving temperature for this period. RETURN The time between returning home and going to bed. You can set the Weekdays only system at a comfortable temperature for this period. SLEEP The time when you are sleeping. You can set up an energy-saving temperature for this period. Weekdays and weekend Programming Tips You do not need to program times and temperatures for all program periods. If you decide not to program your thermostat, it automatically controls heating at 68 F (20 C), and cooling at 78 F (26 C), 24 hours a day. If you decide not to program weekend schedules, the temperature that is programmed for the weekday SLEEP schedule remains in effect until the next program period, which begins on Monday morning. The temperatures cannot be set any higher than 88 F (31 C) or any lower than 45 F (7 C). When pressing the buttons, use the ball of your finger or a soft pencil eraser. Using sharp fingernails or pencil points can damage the keypad. If you make an error at any time during programming, press. Then press until you reach the program period you last programmed
15 Step 3. Program Heating Schedule a. Write in the times and temperatures that you want to program for your heating schedule. Heating Schedule Suggested Settings Weekday (Mon Fri) Weekend (Sat Sun) Program Period WAKE LEAVE RETURN SLEEP Time 6:00 AM 8:00 AM 6:00 PM 10:00 PM Temp 70 F (21 C) 62 F (16.5 C) 70 F (21 C) 62 F (16.5 C) Time Temp Time Temp b. Set the System switch to HEAT. Fig. 20. c. Press once. A blank schedule is displayed (Fig. 20). d. Set the Monday Friday WAKE time by pressing Fig. 21. or until the desired time is displayed (Fig. 21). e. Set the Monday Friday WAKE temperature by pressing or until desired temperature is displayed
16 f. Press to display a blank schedule for the next program period (Fig. 22) and repeat steps d. through f. for each weekday program period. Fig. 22. g. Press until the weekend schedule is displayed Fig. 23. (Fig. 23). h. Set the Saturday and Sunday WAKE time by pressing or until the desired time is displayed. i. Set the Saturday and Sunday WAKE temperature by Fig. 24. pressing or until desired temperature displays (Fig. 24). j. Press again to display blank schedule for SLEEP program period and repeat steps h. through j. to set program. k. Press to start the program
17 Step 4. Program Cooling Schedule a. Write in the times and temperatures you want to program for your cooling schedule. Cooling Schedule Suggested Settings Weekday (Mon Fri) Weekend (Sat Sun) b. Set the System switch to COOL. c. Repeat steps 3c. through 3k. to program the weekday and weekend cooling schedule. Step 5. Check System Verify that your heating system works Program Period WAKE LEAVE RETURN SLEEP Time 6:00 AM 8:00 AM 6:00 PM 10:00 PM Temp 78 F (25.5 C) 85 F (29.5 C) 78 F (25.5 C) 82 F (28 C) Time Temp Time Temp a. Set the System switch to HEAT, and the Fan switch to AUTO. b. Press until the setting is 10 F (6 C) above room temperature (Fig. 25). Your heating system should start and the fan should run after a short delay. Fig. 25. c. Press until the setting is 10 F (6 C) below room temperature. Your heating system should shut off
18 Verify that your cooling system works IMPORTANT: To avoid damaging the compressor in the air conditioner, do not operate the cooling system when the temperature outdoors is below 50 F (10 C). d. Set the System switch to COOL, and the Fan switch to AUTO. Fig. 26. e. Press until the setting is 10 F (6 C) below room temperature (Fig. 26). Your cooling system and fan should start. NOTE: When cooling setting is changed, thermostat can delay up to five minutes before turning on air conditioner. This delay protects the compressor. f. Press until setting is 10 F (6 C) above room temperature.your cooling system and fan should stop. g. Set the System switch to OFF and the Fan switch to AUTO. The cooling system and fan should be off. OPERATION Change Clock for Daylight/Standard Time a. Press once. The time is displayed. b. Press and hold or until the correct time is displayed. c. Press once. The current time and day and current temperature display
19 Set Fan and System Switches The switches on the bottom of the thermostat faceplate control the operation of your fan and the heating and cooling system. Set the Fan switch first and then set the System switch. Switch Setting Result Fan Auto A single-speed fan turns on automatically with the air conditioner or furnace. A two-speed fan usually runs on high with the air conditioner and on low with the furnace. Auto is the normal setting for most homes. On The fan runs continuously. Use this setting for improved air circulation during special occasions or for more efficient air cleaning. NOTE: In a heat-only system, the fan runs continuously only if the fan wire has been connected to the G terminal on the back of the thermostat. System Cool The thermostat controls your air conditioning system. Off Both the heating and air conditioning systems are off. Heat The thermostat controls your heating system. Replace Batteries As the batteries run low, your thermostat shows the following in the digital display: If you see: Batteries are: You should: Flashing bat Lo Low Replace the batteries as soon as possible, within the month. Blank display Dead Replace the batteries immediately. Your heating/cooling system is not operating. a. Make sure that the System switch is set to the OFF position. b. Open the battery door. c. Press on the left side of the batteries to remove them. NOTE: If new batteries are inserted within seconds of removing old ones, reprogramming is not needed. If display is blank, batteries are dead or incorrectly installed and reprogramming is needed
20 d. Install new batteries. Make sure that positive and negative terminals are oriented as marked inside battery case. e. Close the battery door and set the System switch to HEAT or COOL. NOTE: If bat Lo continues to display after replacing the batteries, set System switch to OFF, insert batteries backward, wait for five to ten seconds, and return batteries to correct orientation. Then reprogram. IMPORTANT: Replace batteries once a year to prevent heating/cooling system from shutting down due to lack of battery power in thermostat. If leaving home for longer than a month, change batteries before leaving. Override program settings NOTE: Make sure the System switch is set to either HEAT or COOL before making any changes to the schedule. Change the temperature temporarily Fig. 27. Press or until the desired temperature is displayed. An arrow is displayed, indicating that the change is temporary (Fig. 27). NOTE: A temporary change to temperature lasts for current program period only. Heating/cooling schedule you programmed resumes when next scheduled program period is reached.to cancel temporary change before next scheduled program period, press
21 Hold a temperature indefinitely Use the Hold Temp feature when you want to maintain a constant temperature indefinitely, such as when you go on vacation. Fig. 28. a. Press. HLd is displayed (Fig. 28). b. Press or until the desired temperature is displayed. NOTE: To cancel the hold, press. Check the current programmed temperature Fig. 29. Press to display temperature programmed for current program period. The SET indicator displays briefly along with the programmed temperature (Fig. 29). The display then returns to the room temperature. Check programs Press repeatedly to display the times and temperatures that you programmed. a. Press to resume the program Cancel a program Fig. 30. a. Press until the desired program is displayed (Fig 30)
22 b. Press and simultaneously. A blank program schedule is displayed and the program is canceled (Fig. 31). Fig. 31. Change a program permanently Follow steps for programming heating schedule or programming cooling schedule. FREQUENTLY ASKED QUESTIONS If... Then... Display does not come on Make sure the batteries are fresh and installed correctly. Set System switch to Off. Remove batteries and insert backward for five to ten seconds to reset thermostat. Replace batteries correctly; display should come on. Temperature display does not go lower than 45 F (7 C) or higher than 88 F (31 C) during programming. Temperature limit setting is reached; range is 45 F to 88 F (7 C to 31 C). Display shows flashing bat Lo. The batteries are low; replace them as soon as possible. If bat Lo continues to display after replacing batteries, set System switch to Off and insert batteries backward for five to ten seconds. Replace batteries correctly; display should come on. Temperature change occurs at wrong times Check program times for period in question. Be sure AM and PM indications are correct. Make sure current day and time are correct. Reprogram if necessary
23 If... Heating does not come on Check that the System switch is set to Heat. Check the system fuse or circuit breaker and replace or reset if necessary. Check for correct wiring and good connections. If display is blank or displays bat Lo, install fresh batteries. Allow time for the furnace to heat up and the fan to come on before checking for heat at the register. If temperature setting is higher than current room temperature and SYSTEM ON arrow is displayed, thermostat is operating correctly. Contact heating contractor for assistance. Cooling does not come on Check that the System switch is set to Cool. Check the system fuse or circuit breaker and replace or reset if necessary. Check for correct wiring and good connections. If display is blank or says bat Lo, install fresh batteries. The thermostat has a built-in time delay on cooling. Allow 5-10 minutes after changing setting before air conditioner starts. If temperature setting is lower than room temperature and SYSTEM ON arrow is displayed, thermostat is operating correctly. Contact ac contractor. The house is too warm or too cool Press RUN PROGRAM to check the current temperature setting. If desired, change the temperature setting. Furnace cycles too often or system cycle length is too short or too long Adjust the screws on the back of the thermostat. The thermostat current setting does not match the display temperature to within plus or minus 1 Then... Plug the wiring hole in the wall behind the mounting plate with insulation to prevent drafts that might adversely affect thermostat operation. Be aware that it is normal for the current setting and the displayed room temperature to differ on occasion. During recovery from setback or setup, setting and displayed room temperatures can differ for up to 30 minutes after recovery period. CUSTOMER ASSISTANCE Visit us on the Web at or call Honeywell Customer Care at Before you call, please have the following information available: Thermostat model number and serial code (located under the battery cover). Type of heating/cooling system (hot water, warm air, oil, gas, etc.). Number of wires connected to the thermostat. NOTICE: This equipment is a Class B digital apparatus, that complies with Canadian Radio Interference Regulations, CRC c
24 LIMITED WARRANTY Honeywell warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell s option) within a reasonable period of time.if the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address: Honeywell Inc. USA Honeywell Canada: Dock 4 MN Honeywell Limited/Honeywell Limitée 1885 Douglas Drive North 35 Dynamic Drive Golden Valley, MN Scarborough, Ontario M1V 4Z9 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations Center, 1985 Douglas Dr. N., Golden Valley, MN , or call In Canada, write Retail Products ON30 Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN Scarborough, Ontario M1V 4Z J.S. Rev Printed in U.S.A.
T8131C, T8132C Programmable Thermostat
T8131C, T8132C Programmable Thermostat OWNER S GUIDE Weekday/Weekend Programmable Heat and/or Cool Thermostat and Mounting Plate 1 69-1635-2 Welcome to the world of comfort and energy savings with your
Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT
Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT Weekday, Saturday and Sunday Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3500/CT3595 OWNER S GUIDE Para pedir
its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types
Installation Guide LR-HWLV-HVAC TouchPRO Wireless Touchscreen Thermostat System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, high efficiency furnaces, heat pumps, steam,
Installation Guide. Programmable Thermostat TH6220D
Installation Guide Programmable Thermostat TH6220D Product Application This thermostat provides electronic control of 24 VAC single-stage and multi-stage heating and cooling systems, or 750 mv heating
Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types
Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:
ELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
How To Control A Thermostat
CONTENTS Installation Instructions for Heating & Air Conditioning 1F72 5/2 Day Programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...
HEAT PUMP PROGRAMMABLE THERMOSTAT
HEAT PUMP PROGRAMMABLE THERMOSTAT SA PM 3 COOL TEMP Form 44014-01 r010408 Model 43168 Owners Manual 1 Congratulations! Heat Pump Programmable Thermostat Model 43168 THERMOSTAT CONTROLS Switches & Buttons...15
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
1-877-654-9394. UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com
UP400 Programmable Thermostat Installation Instructions & User Guide For Installation Help 1-877-654-9394 White-Rodgers.com 2011 Printed in China White-Rodgers 8100 West Florissant Avenue St. Louis, MO
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
SINCE 1 8 8 6 AUTO SAVER 550. OwnerÕs Manual Model 44550
SINCE 1 8 8 6 AUTO SAVER 550 5: 7 2 2 3 2 OwnerÕs Manual Model 44550 Ask Your Local Retailer for Other Quality Products from unter Fans Air Purifiers umidifiers To locate your nearest unter Dealer, call
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.
Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA www.luxproproducts.com
PSPA711a LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS 52070 1 COMPATIBILITY...................................... 2 2 FEATURES............................................ 2 3 ELECTRICAL RATINGS................................
1F82-261 Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION ELECTRICAL DATA Electrical Rating: 20 to
1F82-0261 5/1/1 Day Programmable. 1F82-0261 Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1
Blue 2 Heat Pump Thermostat Heat Pump Installation and Operating Instructions Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
YOUR THERMOSTAT REPLACES Assemble tools required as shown below. HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED
1F85-275 Heating & Air Conditioning 5-1-1 Programmable/Non-programmable, Auto Changeover, Multi-Stage/Heat Pump Thermostat INSTALLATION INSTRUCTIONS Operator tor: Save these instructions for future use!
Install Guide CT101. Caution. Caution
Install Guide CT101 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
Install Guide 3M-50. Caution. Caution
PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system.
Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.
Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual
WHITE-RODGERS COMFORT-SET 90 SERIES
INSTALLATI DESCRIPTI WHITE-RODGERS COMFORT-SET 90 SERIES MULTI-STAGE INSTALLATI/CFIGURATI This White-Rodgers Automatic Setback Digital Thermostat uses microcomputer technology to provide precise time and
Installation Questions
Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating
Blue Easy Reader Thermostat 1F95EZ-0671. Homeowner s Guide
Blue Easy Reader Thermostat 1F95EZ-0671 Homeowner s Guide Message to Homeowners Congratulations on choosing the Emerson Blue Easy Reader Thermostat. Blue Easy Reader is designed to be the easiest thermostat
Technical support is also available by email or by phone: [email protected] 1.877.932.6233 (North America) 1.647.428.2220 (International)
Installation guide Welcome! If you have questions, we have answers. Visit ecobee.com/support/ecobee3 for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone: [email protected]
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.
Product Name: CT101 Document Title: CT101 Operation Guide Document Type Code: IBOE Part Number: 1202-004-002 20apr12 Iris inclusion text added mtf 9apr12 bs edits mtf 14mar12 ch edits mtf 13mar12 initial
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Model 53603. Owner s Manual. Español - P. 19 Français - P. 39
Model 53603 Owner s Manual Español - P. 19 Français - P. 39 Table of Contents I. Introduction............................ 1 Sample Watering Plan.......................... 1 II. Installation...........................
Operating Manual. Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil
Operating Manual Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil BE CAREFUL! Never use sharp instruments, such as a pencil or pen, to press touchscreen
ADEMCO 4500 Thermostat
ADEMCO 4500 Thermostat User Guide N7972V1 5/05 Rev. A TABLE OF CONTENTS About the 4500 Thermostat...1 Saving Money on Energy Bills...1 The 4500 Thermostat Provides Comfort and Convenience...1 How the 4500
Carrier Thermostat Quick Reference Guide
Cool Share Web-Programmable Thermostat Residential Carrier Thermostat Quick Reference Guide Thank you for taking an active role in helping reduce the region s demand for electricity during the summer.
UV100E Ultraviolet System
UV100E Ultraviolet System OWNER S GUIDE 69-1573-3 !! UV100E ULTRAVIOLET SYSTEM IMPORTANT Please read these instructions and keep them in your records. HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM OR SURFACE
APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!
Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. APPLICATIONS
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
QUICK INSTALLATION GUIDE
QUICK INSTALLATION GUIDE Read Installer Notes before removing cover from Thermostat. 1F85RF-275 Wireless Remote Kit INSTALLER NOTES IMPORTANT Do not apply power to the thermostat or wireless sensor until
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Wireless Home Security System Product Manual (Model #80355)
Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.
HEAT HEAT COOL HEAT PUMP COOL
OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control
General Information. Do programmable thermostats really save energy?
General Information Do programmable thermostats really save energy? Yes, programmable thermostats can save energy which in turn saves you money on your utility bill. The US Department of Energy states
Automatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Wireless 7 Day Programmable Room Thermostat
Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable
Operation 8022C. Customer Support: 888-515-2585 or Visit our webiste www.ritetemp-thermostats.com Made In China 401-006 OFF FAN HEAT COOL AUTO ON
Operation 8022C HEAT O AN HEAT COOL AUTO ON HEAT O AN HEAT COOL AUTO ON Customer Support: 888-515-2585 or Visit our webiste www.ritetemp-thermostats.com Made In China 401-006 Operation 8022C TEMP UP Time/
1 For All Non-Programmable Digital Thermostat
OWNER'S MANUAL P/N P474-0100 1 For All Non-Programmable Digital Thermostat TOTALINE 68 Dual Setpoint Very easy to program Thermoglow Backlight No batteries required Auto-Changeover Locking Keypad Meets
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
UV100A Ultraviolet Air Treatment System
UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do
Operation Guide 3M-22
Operation Guide 3M-22 TEMP UP Target Temp Time Reset TEMP DOWN Control Panel Heat/Cool Mode Switch Fan Switch Battery Compartment Statement of use: The 3M-22 can be used with - millivolt, 24VAC single
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
Nest Learning Thermostat Installation Guide. Installation step-by-step
Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.
1F87-361 Programmable Electronic Digital Thermostat INSTALLATION AND OPERATION INSTRUCTIONS
1F87-361 Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE INSTALLIN R
Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable
Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10 Programmable thermostat Thermostat programmable Termostato programable Read and save these instructions. Veuillez lire le mode d
AGS. Owner's Manual. Xantrex Automatic Generator Start Control System
AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5
CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?
WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?...an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Mode Switch. Fan Switch Menu button Program button
Operation 3M-30 Day Time of day Target Temperature Time Slot Touch Screen Current Room Temperature Thermostat Mode Statement of use: The 3M-30 can be used with millivolt, 24VAC, single and 2 stage conventional
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
T841A Heating-Cooling Heat Pump Thermostat
T84A Heating-Cooling Heat Pump Thermostat APPLICATIN The T84A Heating-Cooling TADELINE Thermostat provides 4 Vac control of two-stage heating and onestage cooling in heat pump systems, using manual changeover.
Single Zone LCD Thermostat Operating Instructions
Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip
WALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?
WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?...an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods
CR9971 2 Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use
ROBERTS Sound for Generations CR9971 2 Band Auto Set Dual Alarm Clock Radio Please read this manual before use Contents Contents... 1 Controls...2-5 Switching on... 6 Setting the time manually... 6 Setting
Model 5101, 5102, 5103SL, 5110, 5111, 5115 STEEL SECURITY SAFE. Read this manual carefully and never store it inside the safe!
Model 5101, 5102, 5103SL, 5110, 5111, 5115 STEEL SECURITY SAFE Read this manual carefully and never store it inside the safe! Models 5101, 5102, 5103SL, 5110, 5111, 5115 Steel Security Safe PACKAGE CONTENTS
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
INSTALLATION REMOVE OLD THERMOSTAT ATTACH THERMOSTAT BASE TO WALL CHECK THERMOSTAT OPERATION BATTERY LOCATION
HITE-RDERS 1F86-244 Non-Programmable Electronic Digital Thermostat INSTALLATIN AND PERATIN INSTRUCTINS perator: Save these instructions for future use! FAILURE T READ AND FLL ALL INSTRUCTINS CAREFULL EFRE
AROS SMART WINDOW AIR CONDITIONER
AROS SMART WINDOW AIR CONDITIONER Part of the Quirky + GE collection of smart products, Aros is an app-enabled air conditioning unit that reacts to its surroundings to save you Time, Energy & Money. TABLE
Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com [email protected] TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
Owner s Manual. Model 8476 Thermostat with Event-Based Air Cleaning. Includes Operating Instructions and Warranty Information
Model 8476 Thermostat with Event-Based Air Cleaning Owner s Manual Includes Operating Instructions and Warranty Infmation READ AND SAVE THESE INSTRUCTIONS Table of contents About your new thermostat Thermostat
EK908FHL - Thermostat for floor heating
EK908FHL - Thermostat for floor heating EK908FHL is a programmable thermostat designed for floor warming application or helping to limit floor temperature. This thermostat can be used for hot water radiant
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
Installation Instructions
TP-PRH-A, TP-NRH-A Performance Series Edge Thermidistat Control Installation Instructions Programmable Control A07049 A07048 Non Programmable Control Designed and Assembled in the USA. NOTE: Read the entire
37-7498. Professional Contractor INSTALLATION GUIDE
37-7498 Professional Contractor INSTALLATION GUIDE Wireless Setup Connect Exit Next Exit 3 EASY STEPS Installing Sensi thermostat isn t that different than installing a non Wi-Fi thermostat. 1. Install
COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings
Features SMART SWITCH OCCUPANCY SENSOR Installation Manual Maximum Energy savings Sensitive 180º view passive infrared motion detector keeps lights on only when rooms are in use. No ON switch so lights
Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
Weather Radio Alarm Clock
1200093 User s Guide Weather Radio Alarm Clock Thank you for purchasing your Weather Radio Alarm Clock from RadioShack. Please read this user s guide before installing, setting up, and using your new weather
TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser
FITTING AND OPERATING INSTRUCTIONS FOR DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM General information is given in the users instruction leaflet despatched with the appliance and/or on
Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.
Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E. Basic Thermostat Types Many technicians have great difficulty understanding how to properly wire a thermostat or how to replace a thermostat with
ACONT900AC43UA Communicating, Programmable Comfort Control
ACONT900AC43UA Communicating, Programmable Comfort Control OWNER S GUIDE Pub No. 69-1820-04 TABLE OF CONTENTS Page Contents 3 Features 4 Home Screen 6 Programming Your Heating and Cooling Schedule 14 Operating
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
LIGHTING CONTROL PANEL
LIGHTING CONTROL PANEL Installation Guide & User Manual THIS PAGE LEFT INTENTIONALLY BLANK 2 WARRANTY STATEMENT Automated Controls & Systems (ACS) warranties its equipment against defects in workmanship
SC 2201. Installation, Operation & Application Guide
SC 2201 Manual Changeover Non-Programmable Hardwired Non-Programmable Electronic Thermostat For use with Heat Pumps Up to 2-Stage Heat, 2-Stage Cool 30-Minute Power Loss Memory etention For use with 24
GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM
GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM This Quick Start guide will help you start using the MiPower Management System provided by Grayson Collin Electric Cooperative. You should create your
Installation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
INSTALLATION MANUAL RS4220 RS5220 RS6220 RS4110 RS5110 RS6110
RS4110 RS5110 RS4220 RS5220 RS6220 INSTAATIN MANUA 352-00060-001 Rev. A RS4000 Series RS5000 Series RS6000 Series Thank you for purchasing a Robertshaw thermostat. This manual will describe how to install
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The