1 Featuring Manual, Remote Supervisory, and Source-Transfer Models S&C Vista Underground Distribution Switchgear Outdoor Distribution, 15.5 kv through 38 kv
2 Vista Underground Distribution Switchgear Addresses Your Concerns Are you wasting money and resources on timeconsuming, labor-intensive routine operation of your switchgear? Has coordinating upstream protective devices with downstream fusing become a headache? Are your customers complaining that they don t want obtrusive green boxes on their property? S&C s Vista Underground Distribution Switchgear is the answer to these and many other underground distribution system problems. S&C worked closely with electric utilities and power users to identify and satisfy needs that were not being met by conventional underground distribution equipment. Vista UDS is an exceptional product that meets all of these needs. Vista Underground Distribution Switchgear is available in manual, remote supervisory, and source-transfer models. All models feature loadinterrupter switches and resettable, vacuum fault interrupters or arc spinners in series with disconnect switches, elbow-connected and enclosed in a submersible, SF 6 -insulated, welded steel tank. Vista UDS is available with up to six ways, in ratings through 38 kv and 25 ka symmetrical short-circuit. Large windows in the tank provide a clear view of the open gap, ground position, and ground bus. Remote Supervisory Pad-Mounted Style Vista UDS installation. 2
3 Large viewing windows let you see open gap and grounded positions on load-interrupter switches and fault interrupters. Trip indicators are easily checked too Operating panel is located near grade level so UnderCover Style gear is easily operated from a standing position. See page 4 Overcurrent control readily programmed with your PC Fault interrupter terminals equipped with 200-A bushing wells, 600-A bushings, or 900-A bushings Optional voltage indicator with liquid-crystal display. You can check the integrity of the voltage indicator by shining a flashlight on the photocell-powered test circuit, while placing a gloved finger over the test button. See page 8. No flashlight needed in daylight Switch terminals equipped with 600-A bushings or 900-A bushings Bushings and bushing wells are located on one side of the gear, reducing operating space required for elbows and cables 15-kV UnderCover Style Model
4 The load-interrupter switches provide three-pole live switching of 600-ampere or 900-ampere three-phase circuits. The switches have three positions (closed-open-grounded) and provide a clearly visible gap when open. The 200-ampere, 600-ampere, and 900-ampere fault interrupters offer 40-ms fault clearing, have three-position (closed-open-grounded) disconnects, and are available with either single-pole or three-pole switching. Most models of Vista UDS use in-series vacuum fault interrupters for fault clearing. However, the popular 15-kV, 12.5-kA manual models now feature arc-spinning technology for fault interruption... reducing the height of the tank by nearly a foot! Optional voltage indicator with liquid-crystal display. Includes self-test feature Compact welded-steel tank protects switching and protection components from the environment. Stainless-steel construction standard in UnderCover Style Gas-fill port Operating mechanisms for switches and fault interrupters padlockable in any position Pressure gauge (located under window) temperature and altitude compensated Operation selector prevents inadvertent operation from closed position directly to grounded position and vice versa Microprocessor-based overcurrent control housed in watertight enclosure. CTs (not visible) provide power and signal inputs Operating panel of Vista UDS gear. Viewing windows, for confirming open gap and grounded position on loadinterrupter switches and fault interrupters, are located under hinged covers of voltage indicators. 4
5 V T V T V T Vista UDS is available in up to six ways. This means it can accommodate any combination of up to six bus taps, load-interrupter switches, or fault interrupters. With conventional pad-mounted gear, for a looped feeder with four taps, two units of gear are necessary. But with Vista UDS, only one six-way unit is needed. Vista UDS simplifies installation and improves aesthetics by reducing the necessary real estate. The model number indicates the total number of ways, as well as the number of load-interrupter and fault-interrupter ways. For example, Model 321 has 3 ways 2 load-interrupter switch ways and 1 fault-interrupter way, as shown below. Conventional pad-mounted gear Vista Underground Distribution Switchgear LOAD 1 LOAD 2 LOAD 3 LOAD 4 LOAD 1 LOAD 2 LOAD 3 LOAD 4 TYPICAL CONFIGURATIONS OF MANUAL AND REMOTE SUPERVISORY VISTA UDS TYPICAL CONFIGURATIONS OF SOURCE-TRANSFER VISTA UDS V T V T V T 532 (split-bus) 5
6 Vista UDS Offers Numerous Unobtrusive Installation Options One option is the low-profile pad-mounted style. At 15, 25, and even 34.5 kv, pad-mounted Vista UDS is 6 to 14 inches shorter than the average SF 6 -insulated gear. And Vista UDS s total real-estate requirement is less than one-third that of a typical SF 6 -insulated design. This means that Vista UDS is easier to site and allows more room for landscaping options that further improve aesthetics. Vista UDS s most innovative installation offering is the UnderCover style. The UnderCover style is ideal for areas with stringent real-estate restrictions or where aesthetics are extremely important. The Vista UDS gear is installed underground, but all operations are easily performed by one operator above ground. UnderCover style installations can also save money by reducing costs associated with trenching and long cable runs. Vista UDS is also available for floor-mounted or wall-mounted vault installations, and in a man-hole style. With its compact design, rugged construction, and internal visible open point, man-hole style Vista UDS is perfect for applications where installation space is limited. UnderCover Style. Pad-Mounted Style. Vault-Mounted Style available for floor and wall-mounting. Man-Hole Style. 6
7 Vista UDS Operation Is Quicker, Easier, Safer Vista UDS was specifically designed to simplify operating tasks, enhance safety, and minimize the duration of outages. Vista UDS is certified arc-resistant per IEC 298 Appendix AA, for currents up to 12.5 ka symmetrical for 15 cycles (25 ka symmetrical for 15 cycles, for models rated 25 ka short-circuit). In the event of an internal fault, the enclosure will retain its integrity. Just one person is needed to operate Vista UDS. There s no exposure to medium voltage. The procedure is simple: 1. Rotate the switch operating shaft to the open position, then confirm the open gap through the large viewing window. See Figures 1 and 2. With ordinary elbow gear, on the other hand, specially trained operators need to remove the elbows from their bushings using a shotgun clamp stick a tedious task that must be carefully performed. See Figure 3. Grounded position contact Switch blade in open position Closed position contact Figure 1. Opening load-interrupter switch (or fault interrupter). Vacuum bottle Fault interrupter furnished on all Vista UDS except 15-kV manual models. Arc-spinning contact Closed position contact Switch blade in open position Grounded position contact Figure 2. Window cover lifts for viewing switch-blade positions of load-interrupter switch or fault interrupter. Fault interrupter furnished on 15-kV, 12.5-kA manual models. Figure 3. Operation of typical dead-front gear can be awkward and time-consuming. 7
8 2. Confirm that the cable is de-energized so it can be safely grounded. With traditional gear, the mediumvoltage cables must be tested directly using a clampstick-mounted tester. But voltage testing with Vista UDS can be accomplished simply and easily without ever accessing the cables. Simply use the voltage indicators shown in Figure 4. The voltage indicator is even equipped with a self-test function, so you can test the tester. See Figure Ground the cables. Instead of the awkward task of having to move the elbows to parking stands, along with the grounding bushings or elbows, with Vista UDS you need only rotate the switch operating shaft to the grounded position. See Figure 6. Grounding can easily be confirmed by looking through the viewing window. There are even more benefits: The voltage indicator can be furnished with a low-voltage phasing option. See Figure 7. This feature allows confirmation of proper phasing without ever accessing the cables. Vista UDS allows fault-locating and hi-potting tests to be performed with the cables attached and the bus energized. Test circuitry can be powered by flashlight or bright sun Figure 5. Testing the voltage indicator. Place gloved finger over test button to begin testing Photocell for energizing selftest feature Test window Test button LCD display Figure 6. Grounding load-interrupter switch (or fault interrupter). Figure 4. Voltage indicator. Figure 7. Measuring phase-to-phase voltage Phase 1 to Phase 1. 8
9 Overcurrent Control for Superior Coordination Vista UDS utilizes a unique microprocessor-based overcurrent control, housed in a watertight enclosure mounted on the gear. The overcurrent control features a variety of TCC (time-current characteristic) curves with selectable instantaneous and definitetime delay attributes, for superior coordination with upstream protective devices and downstream fusing. The parameters for the TCC curves are set using a personal computer connected to the data port of the overcurrent control. There are no knobs or dials, so the settings cannot be inadvertently changed or altered by unauthorized personnel. Integral current transformers provide power and current sensing. There is even an event recorder that captures information on the last twelve operations of each fault interrupter. TIME IN SECONDS Transformer- Primary Fuse (100E, Standard Speed) 10 Vista Tap Interrupter (Phase) Min. Pickup Current: 400A Def. Time Delay: 4 cycle Phase Overcurrent Relay Type: CO-9 Time Dial: 3 Min. Pickup Current: 720A CTI: 0.15 sec ,000 10, ,000 CURRENT IN AMPERES Coordinating-speed tap curve with definite-time delay eliminates miscoordination problems frequently encountered with transformer fuses. User-supplied personal computer is attached to the overcurrent control for programming the relay in the field. 9
10 Remote Supervisory Vista UDS For distribution automation applications, S&C offers Remote Supervisory Vista UDS. Remote Supervisory Vista UDS provides automated switching and fault protection, and can also perform auto-sectionalizing without tripping the main breaker. Automation features are also retrofittable to existing Manual Vista UDS. Motor operators, current and voltage sensors, and low-voltage compartment are easily installed in the field. Each motor operator includes a control board that provides local push-button and remote operation between the closed, open, and grounded positions. Up to six control boards can be accommodated within the low-voltage compartment, so any or all load-interrupter switches or fault interrupters can be motor operated. The motor Position indicator Operator selector Details of motor operator. Padlock feature 15-kV Remote Supervisory Pad-Mounted Style Model
11 operators may be battery powered or, optionally, self-powered using internal voltage transformers. The low-voltage compartment may also contain a user-specified remote terminal unit and communication device, providing a completely automated switching and protection package. Optional voltage and current sensing round out the Remote Supervisory Vista UDS offering. A variety of RTUs have been successfully integrated in Remote Supervisory Vista UDS, including: ACS, Harris DART, Valmet PoleCAT, QEI/Quindar, Hathaway/Systems Northwest, Motorola MOSCAD, and DAQ. And these transceivers have been integrated: Metricom Utilinet, MDS, Dymec, H&L, and Motorola. RTUs and communication devices of other manufacture can be accommodated too; contact your nearest S&C Sales Office. Details of low-voltage compartment of Remote Supervisory Vista UDS Model 422. Position-indicating lamps Operation push buttons Push-to-test lamps Connector for portable motor operator control Operation counter Vista motor controls for installation with two motor-operated ways. 11
12 When Remote Supervisory Vista UDS is furnished with an EnergyLine 5800 Series Switch Control, it can be a member of an IntelliTEAM, using EnergyLine s revolutionary peer-to-peer communications. IntelliTEAM software supports automatic sectionalizing and reconfiguration, significantly reducing outage time. IntelliTEAM s peer-to-peer communication network uses distributed intelligence, eliminating the need for, but still fully supporting, Remote Supervisory Vista UDS with 5800 Series Switch Control. a SCADA master station. And, when Remote Supervisory Vista UDS is fitted with an EnergyLine switch control, the gear can be used for automatic source transfer, with remote control and monitoring. Remote Supervisory Vista UDS also allows the user to remotely trip the vacuum bottles of any three-phase fault interrupter way using external, user-specified relays. This additional shunt-trip capability permits advanced applications like sensitive earth-ground fault detection, as well as protective relay schemes using high-speed communication for closed-loop and openloop systems. Portable Motor Operator Local motor operation of Vista UDS gear is also available for users who do not require a complete automation package. The portable motor operator includes cabling and hand-held control, all in an easily portable, durable case. The operator easily attaches to any load-interrupter switch or single-pole or three-pole fault interrupter. Then simply plug in the power cable and the control cable. The hand-held control features open, close, and ground push buttons, an enable button to prevent inadvertent operation, and a ready indicating light. Vista UDS Portable Motor Operator. Inset shows hand-held control. 12
13 Case for Vista UDS Portable Operator. Source-Transfer Vista UDS Source-Transfer Vista UDS provides fully automatic primary-selective service for one, two, or three critical load circuits. This package includes all the features of Manual Vista UDS, plus the S&C Micro-AT Source-Transfer Control, three-phase voltage sensing on source ways, and internal power provided by voltage transformers. It is available in common-bus and split-bus configurations. The Micro-AT Source-Transfer Control, located in the low-voltage compartment, ensures a high degree of critical-load continuity by minimizing interruptions resulting from the loss of one source. Excluding the intentional time delay to coordinate with upstream protective devices and/or transition dwell time, transfer is achieved in 6 seconds maximum. The Micro-AT Source-Transfer Control utilizes an advanced microprocessor to perform control operations, as directed by settings programmed into the device at the factory and in the field. Such settings, consisting of the control s operating characteristics and voltage-, current-, and time-related operating parameters, are entered into the control by means of a keypad on the front panel. An unbalance detection feature may be field-programmed in the Micro-AT Source-Transfer Control. This feature protects the loads from any source-side open-phase condition at the same voltage as the Vista Underground Distribution Switchgear. If the voltage unbalance exceeds a preset reference level for a period of time sufficient to confirm that the loss is not transient, an output signal is produced which initiates automatic transfer to the other source. An overcurrent-lockout feature may be furnished which prevents an automatic transfer operation that would close a source load-interrupter switch into a fault. A light-emitting diode lamp indicates when lockout has occurred. Test keys are provided for simulating an overcurrent condition on each source. Micro-AT Source-Transfer Control. 13
14 Standard Three-Phase Ratings123 Amperes, RMS Fault Interrupter Load-Interrupter Switch Applicable Standard Frequency, Hertz Continuous, Load Dropping, and Load Splitting (Parallel or Loop Switching) 456 Fault- Closing, Sym. Fault Interrupting, Sym. Continuous, Load Dropping, and Load Splitting (Parallel or Loop Switching) 456 Fault- Closing, Sym. Momentary, Sym. 1 Sec., Sym. Short- Circuit, Sym. Main Bus Continuous Current7 IEC 50 or 60 ANSI 50 or or or or or Refer to the nearest S&C Sales Office for other ratings. 2 IEC ratings have been assigned in accordance with the applicable portions of IEC for a Class A switch. 3 ANSI ratings have been assigned in accordance with the applicable portions of ANSI C37.71, C37.72, and C Fault interrupters and load-interrupter switches are rated 600 amperes (630 amperes IEC) continuous, load dropping, and loop splitting when furnished with 600-ampere bushings (standard for load-interrupter switches and 25-kA fault interrupters, optional for 12.5-kA fault interrupters). The rating is limited to 200 amperes if 200-ampere bushing wells are used (standard for 12.5-kA fault interrupters, optional for 12.5-kA load-interrupter switches). Models rated 25-kA are only available with 600-ampere bushings. 5 Fault interrupters and load-interrupter switches can switch the magnetizing current of transformers associated with the load-dropping rating. In addition, unloaded cable switching ratings are as follows: 10 amperes at 15.5 kv and 20 amperes at 29 kv and 38 kv ampere is also available ampere is also available. 32,500-ampere peak ten-time duty-cycle rating. 65,000-ampere peak three-time duty-cycle rating. Ten-time duty-cycle fault-clearing rating is 16,000 amperes symmetrical, 41,600 amperes peak. 14
15
16 Printed in U.S.A. Descriptive Bulletin June 1, 2004 Offices Worldwide f
Specifications. S&C Manual Vista Underground Distribution Switchgear Outdoor Distribution (15.5 kv through 38 kv)
Outdoor Distribution ( kv through kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Vista
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
Fusible Disconnect Switch
Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit
Primary and Secondary Electrical Distribution Systems
Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products Utility
Chapter 9 N.C. C. N.O. Single-Pole Double-Throw
rather than providing multiple choices. The sensor modules used may only be suitable for use with the matching controller so it is wise to read the specifications to make sure the unit suits your application.
Arc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
SPECIFICATIONS. S&C Switch Operators Type PM SPECIFICATION BULLETIN 669-31. For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear
S&C Switch Operators Type PM Outdoor Distribution For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth
261000 Medium Voltage Electrical Distribution
Sections Included In This Standard: 1.1 General 1.2 Underground Cable 1.3 Medium Voltage Switches 1.4 Transformers 1.5 Electrical Manholes 1.6 Switch Vaults 1.7 Distribution Switchgear/Switchboards This
S&C TripSaver Dropout Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv
S&C TripSaver Dropout Recloser For enhanced lateral circuit protection at 15 kv and 25 kv Introducing S&C s new TripSaver Dropout Recloser: A better solution for overhead lateral circuit protection at
Part 1 System Modeling & Studies for Existing Systems
Part 1 System Modeling & Studies for Existing Systems Operation Technology, Inc. Copyright 2009 Result of rapid release of energy due to an arcing fault between two conductors. Bus voltages > 208V Temperatures
Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers
Specification Guide for RVAC Direct Replacement AC Medium Voltage Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards...3 3.0 Supplier Qualifications...4 4.0 Circuit Breaker Element
Current Limiting Protector For Systems rated 2.8-38kV and continuous currents through 5000A.
Current Limiting Protector For Systems rated 2.8-38kV and continuous currents through 5000A. Arc Flash and Arc Blast reduction Network protection SCADA adaptable Indoor/outdoor application Professional
Alternate Methods to Short Circuit Breaker Coordination
Alternate Methods to Short Circuit Breaker Coordination Nguyen Perez, PE Senior Electrical Engineer 2600 Douglas Road, Suite 301 Coral Gables, Florida 305.529.1515 (p) www.brplusa.com Importance in Healthcare
STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS
STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS David D. Roybal, P.E. Senior Member, IEEE Cutler-Hammer, Inc. 3697 Mount Diablo Boulevard Lafayette,
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS
DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS ABSTRACT Data Centers are a critical part of the world economic systems. Billions of electronic transactions happen
SECTION 26 1316 MEDIUM-VOLTAGE FUSIBLE INTERRUPTER SWITCHGEAR
SECTION 26 1316 MEDIUM-VOLTAGE FUSIBLE INTERRUPTER SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
Engineers Edge, LLC PDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Interior
GTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
Sample - No Commercial Use
COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
Specifications. Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT:
Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Switch Operators Type CS-1A are high-speed
Instructions For SF 6 Refill Kit
S&C Vista Underground Distribution Switchgear UnderCover, Vault-Mounted, and Pad-Mounted Styles Instructions For SF 6 Refill Kit TABLE OF CONTENTS Section Page Section Page INTRODUCTION..................................
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
DISTRIBUTION OPERATIONS AND MAINTENANCE
EB-00-00 Filed: 00 Aug Page of DISTRIBUTION OPERATIONS AND MAINTENANCE PREVENTIVE MAINTENANCE Preventive Maintenance is intended to maintain or improve customer service reliability, extend equipment life
Engineering Specification
Engineering Specification Electrical 33KV AC INDOOR SWITCHGEAR NON-WITHDRAWABLE Owner: Approved by: Chief Engineer, Electrical Neal Hook Chief Engineer Electrical Authorised by: Version 2.1 Issued May
Low Voltage Switchgear
Arc Resistant Switchgear n Insulated and isolated bus n Separation barriers and top venting n Breaker shutters 12 SWITCHGEAR Arc resistant metal-enclosed low voltage switchgear is an optional product offering
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Choosing the Best Solution for Reducing Arc Energy
CONVENTION SESSION HANDOUT Choosing the Best Solution for Reducing Arc Energy Terry L. Schiazza, Business Development Manager Square D / Schneider Electric SESSION #11 Independent Electrical Contractors
Medium Voltage Motor Control Assemblies
Medium Voltage Motor Control Assemblies Arc Resistant AMPGARD.1 Product............................................. 2 Application........................................... 2 Features, Benefits and Functions...................................
Specifications. S&C Manual PME Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv)
Outdoor Distribution (14.4 kv and 25 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education
Transfer Equipment Controls
Control Types Manual Transfer Switches Nonautomatic Transfer Switches Automatic Transfer Switches The type of control system for the transfer switch will vary depending on the type of switching equipment
HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE
Appendix B-2 - Electrical Safety In Design Final Report TECHNOLOGIES THAT REDUCE LIKELIHOOD OF INJURY FROM ELECTRICAL HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE The following are technologies that reduce
PowlVac Vacuum Integrity Tester
Instructions IB-60025B PowlVac Vacuum Integrity Tester POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900 FAX (713) 947-4453 www.powellelectric.com
Emirates Aluminium starts up World s first fully integrated power distribution system from ABB
Reprint from Aluminium World 2009, Volume 2 Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Emirates Aluminium (EMAL), a joint venture between Abu Dhabi s
Distribution Voltage Regulators
Distribution Voltage Regulators Type JFR Single Phase 2.5 to 19.9 kv Type SFR Three Phase 13.2 to 34.5 kv Power Transmission & Distribution Siemens JFR & SFR Voltage Regulators Improving Quality of Service
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Short Circuit Current Calculations
Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
SWITCHGEAR. EGP Switchgear
SWITCHEA EP Switchgear Cat generator set paralleling switchgear has been designed to integrate with Cat EMCP3 generator set controls. Now you can get greater efficiency, reliability and dependability all
Arc Flash Mitigation. Executive summary. by Antony Parsons, Ph.D., P.E.
by Antony Parsons, Ph.D., P.E. Executive summary Arc flash events can result in significant injury to workers, including severe burn injuries. The most effective arc flash safety programs are not those
Houston Service Center Medium Voltage Service and Aftermarket Solutions
Houston Service Center Medium Voltage Service and Aftermarket Solutions Table of contents Introduction...3 Breaker refurbishment...4 Protective relay & control service and support...5 Power Service and
GE Protection and Control Business Department. Page 1 Date 5/11/99
GE Protection and Control Business Department Page 1 GE Protection and Control Business Department Proven Overcurrent Protection with Power Management Communication The The Advantages of Microprocessor
Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000
Systems Products Motor Control Centers Modan 3 Modan 3 UL / CSA ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER MODAN 3 Motor Control Centers Offer: Over 1 years of Motor Control experience
Bolted contact switches. Pringle switches
Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial
Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
Reverse-feed applications for circuit breakers
Technical Publication PU01200001E Contents Description Page Intoduction.......................................................................... 2 breaker classifications..........................................................
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
ARC FLASH CALCULATIONS & LABELING REQUIREMENTS
ARC FLASH CALCULATIONS & LABELING REQUIREMENTS Presented by: Edmund Elizalde EYP Mission Critical Facilities, Inc. Slides by: Lonnie Lindell SKM Systems Analysis, Inc. 1 Agenda NEC 110.16 NFPA 70E IEEE
Critical-Power Automatic Transfer Systems Design and Application
Critical-Power Automatic Transfer Systems Design and Application Bill Brown, P.E., Jay Guditis, Square D Critical Power Competency Center 1. INTRODUCTION An important requirement of mission-critical electric
Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems
Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in
Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters
S&C Vista SD Underground Distribution Switchgear Pad-Mounted and Vault-Mounted Style Outdoor Distribution (17.5 kv and 29 kv) With Visi-Gap Load Interrupter Switches and Visi-Gap Fault Inetrrupters Replacement
AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
Safety By Design. Strategies for Electrical Contractors
Safety By Design Strategies for Electrical Contractors Introduction Engineering and system design significantly impact worker safety System design provides opportunity to eliminate/minimize workers exposure
Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A
Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear rated voltage 15, 27 and 38 kv rated current 630 A Outdoor circuit breakers GVR Recloser GVR switchgear brings the reliability of modern
SECTION 16426C ARC RESISTANT DRAWOUT SWITCHGEAR (MAGNUM DS) LOW VOLTAGE
ARC RESISTANT DRAWOUT SWITCHGEAR (MAGNUM DS) LOW VOLTAGE PART 1 GENERAL 1.01 1.02 1.03 1.04 SCOPE The Contractor shall furnish and install, where indicated on the drawings, a deadfront type, arc resistant
The Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
Bypass transfer switch mechanisms
Power topic #6013 Technical information from Cummins Power Generation transfer switch mechanisms > White paper By Gary Olson, Director, Power Systems Development This paper describes the configuration
How To Test A Power Switch On A Power Supply
transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability
PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:
PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront
Switchgear and Metal-Enclosed Bus
Section 18 Switchgear and Metal-Enclosed Bus 180. SWITCHGEAR ASSEMBLIES 180A. General Requirements for All Switchgear. This rule covers general requirements for all switchgear. Examples of switchgear found
SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A
SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective
Siemens Fusesaver. Highest availability and cost savings for your MV distribution network. www.siemens.com/fusesaver
www.siemens.com/fusesaver Siemens Fusesaver Highest availability and cost savings for your MV distribution network Answers for infrastructure and cities. 2 In high demand: An intelligent solution Improving
Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.
By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 NEW GAS INSULATED SWITCHGEAR (GIS) FOR ALL MEDIUM VOLTAGE APPLICATIONS H. Fink, ABB Calor Emag Mittelspannungs GmbH; M. Hyrenbach, ABB Calor
SECTION 16999 ELECTRICAL ACCEPTANCE TESTS
SECTION 16999 ELECTRICAL ACCEPTANCE TESTS PART 1 2. AND 3. COMBINED 1.1 SUMMARY A. Description of Systems 1. Furnish all labor, materials, test equipment, and technical supervision to perform and record
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
UFES Active protection for switchgear
Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document
7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units
Automotive Powering business worldwide Aerospace Eaton delivers the hundreds of power distribution products that are answering the demands of today s fast changing world. We help our customers worldwide
How To Build A Germany Power Plant
Medium Voltage Air Insulated Motor Control Featuring AdvanceTM Technology. Medium Voltage Motor Control Center Product Description Contemporary Design Advance TM medium voltage motor control center (MVMCC)
Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions
Overview Brochure Integrated Power Distribution Medium Voltage Assembly Solutions Medium voltage assembly solutions Eaton, a premier leader in manufacturing power distribution and power protection equipment
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.
POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,
Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer [email protected]. Electrical Hazards 2/18/2015. Shock.
Arc Flash Hazards Dan Neeser Field Application Engineer [email protected] Electrical Hazards Electrical Hazards Shock Arc Flash Arc Blast 2 1 Arcing Fault Basics 35,000 F Radiant Heat & UV Speed of
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
Improving Reliability for High-Profile Customers
Improving Reliability for High-Profile Customers By Mark Kimbell Chief Engineer at Murfreesboro Electric Department How important are commercial customers to an electric utility? Are you doing everything
Application of Four-Pole Circuit Breakers within Data Centers
Application of Four-Pole Circuit Breakers within Data Centers December 2013/AT324 by Frank Waterer, Fellow Engineer, Schneider Electric Engineering Services Make the most of your energy SM Revision #1
Power-Zone 4 Arc Resistant Low Voltage Switchgear
Power-Zone 4 Arc Resistant Low Voltage Switchgear with ArcBlok Technology Make the most of your energy SM Workplace safety 2 I Power-Zone 4 Arc Resistant Low Voltage Switchgear Five to ten arc flash explosions
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP
S&C Circuit-Switchers Mark VI
S&C Circuit-Switchers Mark VI Outdoor Transmission (69 kv through 138 kv) Mark VI Circuit-Switcher with Pre-insertion Inductors... the most reliable way to switch and protect substation capacitor banks
Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence
DISTRIBUTION RELIABILITY USING RECLOSERS AND SECTIONALISERS
ABB DISTIBUTION ELIABILITY USING ECLOSES AND SECTIONALISES obert E. Goodin Chief Engineer ABB Inc. Lake Mary, FL Timothy S. Fahey, PE Sr. Application Engineer ABB Inc. aleigh, NC Andrew Hanson, PE Executive
HIGH VOLTAGE SHORE CONNECTION
Guide for High Voltage Shore Connection GUIDE FOR HIGH VOLTAGE SHORE CONNECTION NOVEMBER 2011 American Bureau of Shipping Incorporated by Act of Legislature of the State of New York 1862 Copyright 2011
GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers
GE Consumer & Industrial Electrical Distribution Power Break II Insulated Case Circuit Breakers Table of Contents Power Break II Circuit Breakers......................... 3 Basic Configuration.......................................
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
MCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid
Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a