MEDICAL IMAGING 2nd Part Computed Tomography

Size: px
Start display at page:

Download "MEDICAL IMAGING 2nd Part Computed Tomography"

Transcription

1 MEDICAL IMAGING 2nd Part Computed Tomography

2 Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional projection radiograpgy the image represents the 2D projection of a 3D structure. To obtain information on the real structure the number of projections have to be increased A tomogram is an image of a slice or a plane within the body The basics of CT is to take a series of conventional cross-sectional x-rays while the patient is rotated slightly around an axis between each exposure. A series of projection data is obtained, thes data are used to reconstruct cross-sectional images.

3 Introduction : The austrian mathematician Radon develop a way to reconstruct the density distribution of an object if the line integrals (for every direction) are available : The physician Cormack develops a lot of theoretical work on x- rays creating the basis of CT scanning (without knowing Radon work) 1971: The first CT system has been created by Godfrey N. Hounsfield, he received the Nobel prize in 1979 (together with Cromack) 1972: The first clinical use of a CT system in London, the acquisition time of a couple of tomogram was 5 minutes

4 Introduction : The first II Generation CT system total-body scanner has been realised in the U.S., the acquisition time for 1 tomogram was 1 minute : III and IV Generations CT with acquisition time for 1 tomogram lower than 10 secs 1983: First electron beam CT, very expensive (scarce diffusion) 1989: First helical CT, very low acquisition time (less than 1 sec) and able to explore a large body volume 1992: Dual-slice CT scanner, able to acquire a large number of layers in a very low time 2000: Multislice CT scanner, multiple arrays of detectors; continuous development.

5 Computed Tomography Generations First-generation scanner Second-generation scanner 5 Single source collimated in a pencil beam and single detector Linear scan Arbitrary number of rays and angular projections can be measured, scattered radiation is mostly undetected Partial fan-beam and detectors array. Linear scan Able to complete a full scan in less time than I Generation scanners

6 Computed Tomography Generations Third-generation scanner Fourth-generation scanner 6 Fan-beam and detectos array. Source and detectors rotate in synchrony Dramatic decrease of scan time Fan-beam and large ring of stationary detectos array. Single rotating source Collimators cannot be used in detectors (they must receive energy from a mobile source) high detection efficiency and scattering can cause problems

7 Computed Tomography Generations 7 Main characteristics of the first four CT scanners generations I II III IV Scan Time (sec) Number of detectors (for each layer) Movement Rotation + Transl. Rotation + Transl. Rotation Rotation X-ray tube rotation Data amount (each tomogram) 57.6 kb 57.6 kb 1 MB 2-42 MB Matrix 80x80 80x80 256x x512

8 Computed Tomography Generations Fifth-generation scanner: electron beam computed tomography (EBCT); no moving parts, a electronically steered electron beam is used, this beam hit one of the four tugsten anode strip encircling the patient. This produces x-rays that are collimated in a fan-beam and revealed by a stationary ring of detectors. A full set of data are acquired in 50 milliseconds. Very expensive Sixth-generation scanner: helical CT addresses the need for rapid volumetric data acquisition. Conventional arrangement of source and detctors (III and IV generations) which can continuously rotate. During tube rotation patient table is slightly moved through the sourcedetectors plane. The image acquisition is not sequential (as it is for previous CT generations) but volumetric 8 A) sequential scanning B) helical scanning

9 Computed Tomography Generations Seventh-generation scanner: multislice CT scanners, a thick fan-beam is used and multiple detectors array are used to collect the x-rays. This technology is in continuous development, recently (and 256) multiple detectors array has been developed. 9 With the 256-slice system the entire heart can be covered in a single rotation Helical and multislice CT has made the requirements for new development in data processing techniques even more critical Future development: multislice scanners able to interact with a cone-beam Due to the large volume that can be explored it will be possible to stop using mobile patient table, this will decrease the complexity in image reconstruction

10 CT Instrumentation 10 Most of the commercial medical CT scanners use just one x-ray source. X-ray tubes usually wear out in less than one year and need frequent status control and calibration. X-rays generated by the tube require collimation and filtration. Typically fan-beam geometry (having degress of fan angle) is obtained through two pieces of lead that form a slit between them. Slit width is adjustable by the operator in order to obtain different fanbeam thickness, typically between 0.5 and 10 mm for single slice systems and 20 to 30 mm for multislice CT systems. Fan-angle Thickness mm X-rays fan-beam

11 CT Instrumentation 11 Different types of CT detectors: Solid state detectors contain a scintillation crystal able to interact with x-rays and produce photoelectrons that are captured by a photo-diode and converted to electric current Xenon gas detectors long thin tubes containing compressed xenon gas, when ionized the gas generates a current between anode and cathode. Less efficient than solid state detectors but highly directional Slip ring solves the mechanical problem of continuous electrical contact with rotating gantry; the gantry holds the x-ray tube (that needs high voltage to work properly) and the detectors that generate hundreds of signals to be transmitted out

12 Data Acquisition If a thin beam of monoenergetic x-rays, having an intensity of, propagates for a distance d through an omogenic material, the intensity of the attenuated beam is: I 0 12 I = Ie µd 0 I0 µ I Being µ the linear attenuation coefficient µ is a function of material atomic number and electronic density d If the beam propagates through different omogenic materials the intensity of the attenuated beam is: d µ i ( µ 1+ µ µ n) d i= I = I e = I e n I0 x µ 1 µ 2 µ n d I

13 Data Acquisition 13 If the material has a continuous variable attenuation coefficient the intensity of the attenuated beam is: I = I e 0 0 D dx Given a measurement of and knowledge of, the projection measurement is defined as: p I 0 I0 I = ln( ) = I 0 D µ dx Therefore the basic measurement of a CT scanner is a line integral of the linear attenuation coefficient x I 0 x D I

14 Data Acquisition A CT scanner has to be calibrated in order to obtain the reference intensity I 0 Multiple projections (along parallel lines) create a so-called attenuation profile 14 CT detectors are able to measure the line integrals of bidimensional distribution of linear attenuation coefficients Through a suitable number of attenuation profiles it is possible to identify the bidimensional distribution of attenuation coefficients and it is possible to reconstruct the bidimensional image. Attenuation profile

15 CT Numbers 15 Different CT have different x-rays tubes, so the same object will produce differenc values of µ on different scanners (the value of µ is a function of: x-ray energy, tissue density and atomic number) In order to compare data from different scanners is not possible to calculate absolute values of linear attenuation coefficents but at each pixel is associated a numerical value called CT number A CT number is calculated in Hounsfield units (UH) and is defined as: µ w µ t µ w h = 1000 µ Being the water attenuation coefficient and the tissue attenuation coefficient A CT number is 10 times the percentual difference between µ and t µ w divided by µ w w µ t

16 CT Numbers 16 As an example, a tissue having a attenuation coefficient 4% bigger than water has a CT number: h t (1.04 µ w µ w) = 1000 = 40 µ w Clearly h=0 for water, that is the reference value. Since µ = 0 for air, it is possible to find that h=-1000 for air. The largest CT number found naturally in the body are for bones, 1000 HU for average bone. CT numbers can surpass 3000 HU for metal and contrast agents A typical HU range is: / 3071 (4096 levels, 12 bits each pixel)

17 CT Numbers Examples of typical HU values 17

18 CT Numbers Windowing 18

19 CT Numbers Conventional CT scan without contrast showing possible tumor in the liver Conventional CT scan of the same patient using contrast

20 Image Formation 20 CT images are reconstructed as a numerical bidimensional matrix. Each element of the matrix is called pixel The number of pixels is variable between 256x256 and 1024x1024 For each couple of x and y, the pixel represent a micro bidimensional area and f(x,y) is the functional value of this area f(x,y) is a grey level value, positive integer power of 2 NxN matrix As a matter of fact this is a bidimensional representation of a tridimensional tissue volume f(x,y)

21 Image Representation 21 Each pixel of the bidimensional matrix represents the properties of a tissue volume called voxel Voxel dimension is a function of the field of view (FOV) In general the voxel cross-sectional plane dimensions are lower than the one of z axis (along-ray), voxels are parallelepiped Spatial resolution along z axis is lower than the one along x and y axes Anisotropy pixel y voxel x z

22 Parallel Ray Reconstruction 22 The basic CT measurements is a line integral of the effective linear attenuation coefficient within a cross-section µ We desire a picture of or a CT number over the entire cross-section. Can we reconstruct a picture of given a collection of its line integrals? µ The answer is yes! A line in the (x, y) plane is given by: { } L(, l θ) = ( x, y) xcosθ + ysinθ = l The unit normal to the line is oriented at an angle relative to x axis and the line is at distance l from the origin in the direction of the unit normal θ

23 Parallel Ray Reconstruction 23 The line integral of function f(x,y) is defined as: gl (, θ) = f( xy, ) δ( xcosθ + ysin θ ldxdy ) Being the line impulse defined as: δl ( xy, ) = δ( xcosθ + ycos θ l) The inpulse shifting property causes the integrand to be zero everywhere except on the line For a fixed θ glθ (, ), is called a projection θ l glθ (, ) For all and, is called the 2D Radon Transform of f( x, y)

24 Parallel Ray Reconstruction 24 If we make the following identifications f( x, y) = µ ( x, y) Unknown function to be reconstructed by CT I gl (, θ ) = ln( ) I CT Measurements It is possible to see that this mathematical abstraction characterizes the CT measurement situation It has to be noticed that this definition of projection corresponds to a collection of line integrals of parallel lines. This correspond to the geometry of 1G scanners only. However this formalism and methods can be applied also to reconstruct fan-beam projections. 0

25 Sinogram 25 glθ (, ) An image of with l and θ as rectilinear coordinates is called a SINOGRAM A sinogram is a pictorial representation of the Radon transform of and represents the data that are needed to reconstruct it There is no need to calculate the sinogram for angles higher than π since these projections are redundant f( x, y)

26 Backprojection glθ (, ) f( x, y) Let be the 2D Radon transform of. Consider the projection at θ = θ 0. There are an infinite number of functions that could give rise to this projection; it is not possible to determine uniquely form a single projection f( x, y) glθ (, ) l = l f( x, y) 0 Ll (, θ ) If takes on a large value at, then must be large 0 over the line (or somewhere over the line) 0 0 One way to create an image exploiting this property is to simply assign every point on the value of Ll (, θ ) gl ( 0, θ0) 0 0 l If we repeat this for every, the resulting function is called backprjection image and is given by bθ ( x, y) = g( xcosθ + ysin θθ, ) The backprojection image at a angle is consistent with the projection at θ 0 but its values are assigned with no prior information about the distribution of the image intensities θ 0 26

27 Backprojection It is possible to add-up backprojection images for every angle, obtaining the backprojection summation image, also called laminogram (, ) π f (, ) b x y = bθ x y dθ 0 27 Not the correct way to reconstruct f( x, y) Backprojection for θ = 30 Laminogram (blurriness)

28 d µ r 0 I Ie µ r = d 0 Backprojection I Ie µ r = d Backprojection assumption x x x x x I = I0e µ µ µ µ µ µ = µ /5 x ( d + d + d + d + d) r Object density is distributed along the whole x-ray path Star-like Artifact Backprojection (2 projections) Backprojection (4 projections)

29 Projection-Slice Theorem 29 Lets take the 1D Fourier transform of a projection with respect to l πρl G( ρθ, ) F gl (, θ) gl (, θ) e dl = = 1D Being { } j2 ρ the spatial frequency glθ (, ) If we substitute the analitical expression of it is possible to obtain j2πρl G( ρθ, ) = f ( x, y) δ( x cosθ+ y sin θ l) e dxdydl j2 l f( x, y) πρ δ( xcosθ ysin θ l) e dldxdy = + = f ( x, y) e j2 πρ ( xcosθ + ysin θ ) dxdy

30 Projection-Slice Theorem 30 The last expression is reminescent of the 2D Fourier transform of j2 ( xu yv) F( u, v) = π + f ( x, y) e dxdy Being u and v the frequency variables in the x and y directions u = ρ cosθ v = ρ sinθ G( ρ, θ) = F( ρcos θ, ρsin θ) f( x, y) Making the following identifications: and leads to a very important equivalence, called the projection-slice theorem The 1D Fourier transform of a projection is a slice of the 2D Fourier transform of the object. The 1D Fourier transform of the projection, calculated along a direction, equals the Fourier transform of the object calculated along the same direction passing through the origin

31 Projection-Slice Theorem Graphical representation of the theorem 31 ρ θ and can be interpretated as the polar coordinates of the 2D Fourier transform

32 The Fourier Method 32 A very simple image reconstruction method follows immediately from the projection-slice theorem Take the 1D Fourier transform of each projection, insert it with the corresponding correct angular orientation into the correct slice of the 2D Fourier plane, and take the inverse 2D Fourier transform f( x, y) = F G( ρ, θ ) 2D 1 { } This method is not widely used in CT due to some practical problems: Interpolating polar data onto a Cartesian grid 2D inverse Fourier transform is time-consuming

33 Filtered Backprojection 33 The inverse Fourier transform of F( uv, ) can be written in polar coordinates 2π 2 ( cos sin ) (, ) ( cos, sin ) j πρ f x y F e x θ + y θ = d d 0 0 ρ θ ρ θ ρ ρ θ Using the projection-slice theorem π 2 ( cos sin ) (, ) (, ) j πρ f x y G e x θ + y θ d d 0 = ρ θ ρ ρ θ The term xcosθ y being gl (, θ ) = g( l, θ + π) θ + sin is constant considering integration over ρ f x y ρ G ρθ e dρ dθ π 2 (, ) (, ) j πρ = l 0 l= xcosθ+ ysinθ

34 Filtered Backprojection 34 The inner integral of the previous formula is an inverse 1D Fourier transform ρ The term makes it a filtering equation. The Fourier transform of a projection is multiplied by a frequency filter and inverse-transformed After the inverse-transform, the filtered projection is backprojected (this is done replacing l = xcosθ + ysinθ ), and then is performed a summation of all filtered projection ρ This reconstruction approach is called filtered backprojection and is faster and more flexible with respect to the Fourier method The term ρ is called ramp filter

35 Convolution Backprojection 35 From the convolution theorem of Fourier transforms follows π 1 { } 0 1D l= xcosθ+ ysinθ f( x, y) = F ρ g( l, θ ) d θ Defining cl () = F 1 1D { ρ } π 0 [ θ ] = cosθ+ sin f ( x, y ) = c ( l ) g ( l, ) d l x y θ θ π = gl (, θ ) cx ( cosθ + ysin θ ldld ) θ 0 Substitution of the convolution integral to obtain the equation for convolution backprojection

36 Convolution Backprojection 36 Performing a convolution rather than a filtering operation is generally more efficient if the inpulse response is narrow (it is so in this case) cl () does not exists since ρ is not integrable In practice ρ is windowed with suitable windowing functions Convolution backprojection algorithms use an approximate impulse response cl () = F D W 1 1 { ρ ( ρ )}

37 Reconstruction 37 Filtered backprojection uses three basic steps to reconstruct an image from a sinogram: filtering, backprojection and summation Convolution backprojection uses the same steps except that filtering is performed using a convolution Filtering step: each row of the sinogram is filtered through a ramp filter to obtain the filtered sinogram Ramp filter is essentially a high-pass filter and its value for f=0 is 0 High-frequency details are accentuated

38 Reconstruction 38 Backprojection is applied to each filtered projection, rather than to the raw data Last setp is the summation of filtered backprojections This step is performed using an accumulator concept No need to store hundreds of backprojection images

39 Reconstruction 39

40 CT Image Quality 40 CT image quality can be expressed as a function of: Spatial resolution in the transversal plane xy Longitudinal resolution and slice sensitivity profile Noise Some indicators of CT image quality will be introduced Contrast Artifacts

41 CT Image Quality 41 Spatial resolution is a function of the smalles details that can be identified in the image; it is stricly dependant on the detectors (and, in general, on the intruments used for data acquisition and reconstruction). Spatial resolution is measure of how closely lines can be resolved in an image, it is measured in mm or LP/cm (line pairs/cm). The clarity of the image is not the number of pixels in an image, in fact spatial resolution refers to the number of independent pixel values per unit length. Detectable lines Undetectable lines

42 CT Image Quality 42 Pixel dimensions can be considered the upper limit of the spatial resolution It is not possible to identify details having dimensions lower than pixel size Details having dimensions comparable to the pixel ones provides contributions to adjacent pixels

43 CT Image Quality 43 Slice sensitivity profile (SSP) is the impulse response of the CT system along the z axis (patient long axis). Thick slice Thin slice

44 CT Image Quality Image width affects contrast and noise of object Optimised slice width: imaged slice object size 44 Object 5mm 5mm Low contrast Low noise 1mm Better contrast More noise

45 CT Image Quality Noise is the random variation of color (grayscale), some regions of the image that should be uniform show coarseness 45 Noise is produced by the sensors and circuitry of the scanner Noise intensity can be evaluated considering a region of the image; the mean pixels intensity of the region is calcualted as well as standard deviation standard deviation Noise = % mean intensity Noise can be reduced through reconstruction filters Noise is in inverse proportion to layer thickness and radiation dose root square

46 CT Image Quality 46 Different kind of filters can be used in backprojection to optimize spatial resolution against noise: smooth, standard, detail, bone, etc. Smooth Filtering Low contrast Low noise Sharp Filtering Better contrast More noise

47 Artifacts 47 Artifacts can appear in CT images, due to different reasons Aliasing: if projections are undersampled higher frequency information will appear as lower frequency artifacts. An high number of detectors is needed, it is needed to sample at numerous angles Beam hardening: when travelling through te body the x-rays beam spectrum component with low energy is almost completely absorbed and the mean energy increases (this artifacs affect the bones) Other: electornic or system drift (miscalibration), x-ray scatter (can be prevented using collimators at expense of lower efficiency), motion (typically a scan require 1 to 10 secs) Beam herdening artifact

Cone Beam Reconstruction Jiang Hsieh, Ph.D.

Cone Beam Reconstruction Jiang Hsieh, Ph.D. Cone Beam Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced acquisition

More information

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E.

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E. 1 Overview CT scanning By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E. Wilhjelm) As it can be imagined, planar X-ray imaging has

More information

CT Image Reconstruction. Terry Peters Robarts Research Institute London Canada

CT Image Reconstruction. Terry Peters Robarts Research Institute London Canada CT Image Reconstruction Terry Peters Robarts Research Institute London Canada 1 Standard X-ray Views Standard Radiograph acquires projections of the body, but since structures are overlaid on each other,

More information

Introduction to Medical Imaging. Lecture 11: Cone-Beam CT Theory. Introduction. Available cone-beam reconstruction methods: Our discussion:

Introduction to Medical Imaging. Lecture 11: Cone-Beam CT Theory. Introduction. Available cone-beam reconstruction methods: Our discussion: Introduction Introduction to Medical Imaging Lecture 11: Cone-Beam CT Theory Klaus Mueller Available cone-beam reconstruction methods: exact approximate algebraic Our discussion: exact (now) approximate

More information

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through

More information

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW Qiang Lu Chapter 3. System Scanning Hardware Overview 79 Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW Since all the image data need in this research were collected from the highly modified AS&E 101ZZ system,

More information

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM João Antônio Palma Setti, j.setti@pucpr.br Pontifícia Universidade Católica do Paraná / Rua Imaculada

More information

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,

More information

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction Digital Industrial Radiology and Computed Tomography (DIR 2015) 22-25 June 2015, Belgium, Ghent - www.ndt.net/app.dir2015 More Info at Open Access Database www.ndt.net/?id=18046 Computed Tomography Resolution

More information

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays J. E. Wilhjelm Ørsted TU Technical University of enmark, Bldg. 348, K-2800 Kongens Lyngby, enmark. X-ray and Computed Tomography Contents History and characterization of X-rays Conventional (projection)

More information

EECS 556 Image Processing W 09. Interpolation. Interpolation techniques B splines

EECS 556 Image Processing W 09. Interpolation. Interpolation techniques B splines EECS 556 Image Processing W 09 Interpolation Interpolation techniques B splines What is image processing? Image processing is the application of 2D signal processing methods to images Image representation

More information

Purchasing a cardiac CT scanner: What the radiologist needs to know

Purchasing a cardiac CT scanner: What the radiologist needs to know Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London maria.lewis@stgeorges.nhs.uk CT scanner development Slice wars 1998 Increased z-coverage

More information

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999 Spiral CT: Single and Multiple Detector Systems AAPM Refresher Course Nashville, TN July 28,1999 Mike McNitt-Gray, PhD, DABR Assistant Professor UCLA Radiological Sciences mmcnittgray@mednet.ucla.edu X-Ray

More information

5 Factors Affecting the Signal-to-Noise Ratio

5 Factors Affecting the Signal-to-Noise Ratio 5 Factors Affecting the Signal-to-Noise Ratio 29 5 Factors Affecting the Signal-to-Noise Ratio In the preceding chapters we have learned how an MR signal is generated and how the collected signal is processed

More information

State of Stress at Point

State of Stress at Point State of Stress at Point Einstein Notation The basic idea of Einstein notation is that a covector and a vector can form a scalar: This is typically written as an explicit sum: According to this convention,

More information

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13 Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer

More information

BIOMEDICAL ULTRASOUND

BIOMEDICAL ULTRASOUND BIOMEDICAL ULTRASOUND Goals: To become familiar with: Ultrasound wave Wave propagation and Scattering Mechanisms of Tissue Damage Biomedical Ultrasound Transducers Biomedical Ultrasound Imaging Ultrasonic

More information

Polarization of Light

Polarization of Light Polarization of Light References Halliday/Resnick/Walker Fundamentals of Physics, Chapter 33, 7 th ed. Wiley 005 PASCO EX997A and EX999 guide sheets (written by Ann Hanks) weight Exercises and weights

More information

Fundamentals of Cone-Beam CT Imaging

Fundamentals of Cone-Beam CT Imaging Fundamentals of Cone-Beam CT Imaging Marc Kachelrieß German Cancer Research Center (DKFZ) Heidelberg, Germany www.dkfz.de Learning Objectives To understand the principles of volumetric image formation

More information

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time Module 8: IQ: Acquisition Time IQ : Acquisition Time Objectives...Describe types of data acquisition modes....compute acquisition times for 2D and 3D scans. 2D Acquisitions The 2D mode acquires and reconstructs

More information

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical

More information

Synthetic Sensing: Proximity / Distance Sensors

Synthetic Sensing: Proximity / Distance Sensors Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,

More information

Computed Tomography. 62.1 Instrumentation. Ian A. Cunningham. Data-Acquisition Geometries. Ian A. Cunningham

Computed Tomography. 62.1 Instrumentation. Ian A. Cunningham. Data-Acquisition Geometries. Ian A. Cunningham 62 Computed Tomography Ian A. Cunningham Victoria Hospital, the John P. Robarts Research Institute, and the University of Western Ontario Philip F. Judy Brigham and Women s Hospital and Harvard Medical

More information

PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors

PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors Quality Control in PET PET/CT QC/QA Magnus Dahlbom, Ph.D. Division of Nuclear Medicine Ahmanson Biochemical Imaging Clinic David Geffen School of Medicine at UCLA Los Angeles Verify the operational integrity

More information

DICOM Correction Item

DICOM Correction Item Correction Number DICOM Correction Item CP-626 Log Summary: Type of Modification Clarification Rationale for Correction Name of Standard PS 3.3 2004 + Sup 83 The description of pixel spacing related attributes

More information

Image Analysis for Volumetric Industrial Inspection and Interaction

Image Analysis for Volumetric Industrial Inspection and Interaction Image Analysis for Volumetric Industrial Inspection and Interaction Rasmus Larsen Mads F. Hansen, Hildur Olafsdottir, Thomas H. Mosbech, Lasse F. Laursen DTU Informatics (CT) reconstruction from few projections

More information

Common Core Unit Summary Grades 6 to 8

Common Core Unit Summary Grades 6 to 8 Common Core Unit Summary Grades 6 to 8 Grade 8: Unit 1: Congruence and Similarity- 8G1-8G5 rotations reflections and translations,( RRT=congruence) understand congruence of 2 d figures after RRT Dilations

More information

Manual for simulation of EB processing. Software ModeRTL

Manual for simulation of EB processing. Software ModeRTL 1 Manual for simulation of EB processing Software ModeRTL How to get results. Software ModeRTL. Software ModeRTL consists of five thematic modules and service blocks. (See Fig.1). Analytic module is intended

More information

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners Background The lateral response artifact (LRA) in radiochromic film images from flatbed scanners was first pointed

More information

Medical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute andek@vtc.vt.

Medical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute andek@vtc.vt. Medical Image Processing on the GPU Past, Present and Future Anders Eklund, PhD Virginia Tech Carilion Research Institute andek@vtc.vt.edu Outline Motivation why do we need GPUs? Past - how was GPU programming

More information

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Medical and Industrial Tomography - W.B.Gilboy

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Medical and Industrial Tomography - W.B.Gilboy MEDICAL AND INDUSTRIAL TOMOGRAPHY Department of Physics, University of Surrey, Guildford, Surrey, U.K. Keywords: Radiography, transmission tomography, emission tomography, microtomography, SPECT (single

More information

Computerized Tomography, X-rays, and the Radon Transform

Computerized Tomography, X-rays, and the Radon Transform 1 Computerized Tomography, X-rays, and the Radon Transform 1.1 Introduction The purpose of this chapter is to give an informal introduction to the subject of tomography. There are very few mathematical

More information

Methods of Computerized Images for Medical Diagnosis Seminar: Medical Images Summer Semester 2005

Methods of Computerized Images for Medical Diagnosis Seminar: Medical Images Summer Semester 2005 + Methods of Computerized Images for Medical Diagnosis Seminar: Medical Images Summer Semester 2005 Author: Tu-Binh Dang Matr.: 6147230 For: Professor Domik University of Paderborn Tutor: Gitta Domik domik@upb.de

More information

Introduction to acoustic imaging

Introduction to acoustic imaging Introduction to acoustic imaging Contents 1 Propagation of acoustic waves 3 1.1 Wave types.......................................... 3 1.2 Mathematical formulation.................................. 4 1.3

More information

MODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT

MODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT MODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT C. Reinhart, C. Poliwoda, T. Guenther, W. Roemer, S. Maass, C. Gosch all Volume Graphics GmbH, Heidelberg, Germany Abstract:

More information

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1. R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction

More information

Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES

Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES 1.0 SCOPE AND PURPOSE These specifications apply to fingerprint capture devices which scan and capture

More information

CT Traceability - Prof. Wim Dewulf, Group T - KU Leuven

CT Traceability - Prof. Wim Dewulf, Group T - KU Leuven CT Traceability - Calibration and Accuracy Prof. Wim Dewulf, Group T - KU Leuven Outline Introduction: terminology and procedures Voxel size calibration Edge offset calibration Conclusions Outline Introduction:

More information

Scientific Data Visualization Foundation

Scientific Data Visualization Foundation Scientific Data Visualization Foundation Data Sources Scientific Visualization Pipelines Data Acquisition Methods GeoVisualization 1 Scientific Data Sources Common data sources: Scanning devices Computation

More information

Data. microcat +SPECT

Data. microcat +SPECT Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for

More information

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology

More information

A System for Capturing High Resolution Images

A System for Capturing High Resolution Images A System for Capturing High Resolution Images G.Voyatzis, G.Angelopoulos, A.Bors and I.Pitas Department of Informatics University of Thessaloniki BOX 451, 54006 Thessaloniki GREECE e-mail: pitas@zeus.csd.auth.gr

More information

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Fundamentals of modern UV-visible spectroscopy. Presentation Materials Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms

More information

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM

More information

Page: 1 of 6 Page: 1 of 6

Page: 1 of 6 Page: 1 of 6 Page: 1 of 6 Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique

More information

Graphical displays are generally of two types: vector displays and raster displays. Vector displays

Graphical displays are generally of two types: vector displays and raster displays. Vector displays Display technology Graphical displays are generally of two types: vector displays and raster displays. Vector displays Vector displays generally display lines, specified by their endpoints. Vector display

More information

Instruction Sheet 554 828

Instruction Sheet 554 828 08/13-W07-Hund Instruction Sheet 554 828 X-ray image sensor (554 828) Precision slide X-ray image sensor (554 829) Software Computed Tomography Pro (554 820) Sensor head on precision slide with USB module

More information

Solving Simultaneous Equations and Matrices

Solving Simultaneous Equations and Matrices Solving Simultaneous Equations and Matrices The following represents a systematic investigation for the steps used to solve two simultaneous linear equations in two unknowns. The motivation for considering

More information

Section 1.1. Introduction to R n

Section 1.1. Introduction to R n The Calculus of Functions of Several Variables Section. Introduction to R n Calculus is the study of functional relationships and how related quantities change with each other. In your first exposure to

More information

How To Improve Your Ct Image Quality

How To Improve Your Ct Image Quality Translating Protocols Between Scanner Manufacturer and Model Cynthia H. McCollough, PhD, FACR, FAAPM Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo

More information

Waves - Transverse and Longitudinal Waves

Waves - Transverse and Longitudinal Waves Waves - Transverse and Longitudinal Waves wave may be defined as a periodic disturbance in a medium that carries energy from one point to another. ll waves require a source and a medium of propagation.

More information

COMP175: Computer Graphics. Lecture 1 Introduction and Display Technologies

COMP175: Computer Graphics. Lecture 1 Introduction and Display Technologies COMP175: Computer Graphics Lecture 1 Introduction and Display Technologies Course mechanics Number: COMP 175-01, Fall 2009 Meetings: TR 1:30-2:45pm Instructor: Sara Su (sarasu@cs.tufts.edu) TA: Matt Menke

More information

C1 Medical Imaging Modalities & Characteristics. 4005-759 Linwei Wang

C1 Medical Imaging Modalities & Characteristics. 4005-759 Linwei Wang C1 Medical Imaging Modalities & Characteristics 4005-759 Linwei Wang Major Types of Medical Imaging Modalities X-ray Imaging Computed Tomography (CT) Magnetic Resonance Imaging (MRI) Nuclear Imaging Positron

More information

The accurate calibration of all detectors is crucial for the subsequent data

The accurate calibration of all detectors is crucial for the subsequent data Chapter 4 Calibration The accurate calibration of all detectors is crucial for the subsequent data analysis. The stability of the gain and offset for energy and time calibration of all detectors involved

More information

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Experimental study of beam hardening artefacts in photon counting breast computed tomography Experimental study of beam hardening artefacts in photon counting breast computed tomography M.G. Bisogni a, A. Del Guerra a,n. Lanconelli b, A. Lauria c, G. Mettivier c, M.C. Montesi c, D. Panetta a,

More information

APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS

APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS V.A. Popovich 1, W. Verwaal 2, M. Janssen 1, I. J. Bennett 3, I.M.Richardson 1, 1. Delft University of Technology, Department of Materials

More information

Powder diffraction and synchrotron radiation

Powder diffraction and synchrotron radiation Powder diffraction and synchrotron radiation Gilberto Artioli Dip. Geoscienze UNIPD CIRCe Center for Cement Materials single xl diffraction powder diffraction Ideal powder Powder averaging Textured sample

More information

Practice Final Math 122 Spring 12 Instructor: Jeff Lang

Practice Final Math 122 Spring 12 Instructor: Jeff Lang Practice Final Math Spring Instructor: Jeff Lang. Find the limit of the sequence a n = ln (n 5) ln (3n + 8). A) ln ( ) 3 B) ln C) ln ( ) 3 D) does not exist. Find the limit of the sequence a n = (ln n)6

More information

Lecture 14. Point Spread Function (PSF)

Lecture 14. Point Spread Function (PSF) Lecture 14 Point Spread Function (PSF), Modulation Transfer Function (MTF), Signal-to-noise Ratio (SNR), Contrast-to-noise Ratio (CNR), and Receiver Operating Curves (ROC) Point Spread Function (PSF) Recollect

More information

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters www.led-professional.com ISSN 1993-890X Trends & Technologies for Future Lighting Solutions ReviewJan/Feb 2015 Issue LpR 47 International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in

More information

IMAGE PROCESSING AND DATA ANALYSIS IN COMPUTED TOMOGRAPHY

IMAGE PROCESSING AND DATA ANALYSIS IN COMPUTED TOMOGRAPHY IMAGE PROCESSING AND DATA ANALYSIS IN COMPUTED TOMOGRAPHY E. D. SELEÞCHI 1, O. G. DULIU 2 1 University of Bucharest, Faculty of Physics, Romania 2 University of Bucharest, Department of Atomic and Nuclear

More information

Encoders for Linear Motors in the Electronics Industry

Encoders for Linear Motors in the Electronics Industry Technical Information Encoders for Linear Motors in the Electronics Industry The semiconductor industry and automation technology increasingly require more precise and faster machines in order to satisfy

More information

X-ray thin-film measurement techniques

X-ray thin-film measurement techniques Technical articles X-ray thin-film measurement techniques II. Out-of-plane diffraction measurements Toru Mitsunaga* 1. Introduction A thin-film sample is two-dimensionally formed on the surface of a substrate,

More information

Ultrasonic Wave Propagation Review

Ultrasonic Wave Propagation Review Ultrasonic Wave Propagation Review Presented by: Sami El-Ali 1 1. Introduction Ultrasonic refers to any study or application of sound waves that are higher frequency than the human audible range. Ultrasonic

More information

Robot Perception Continued

Robot Perception Continued Robot Perception Continued 1 Visual Perception Visual Odometry Reconstruction Recognition CS 685 11 Range Sensing strategies Active range sensors Ultrasound Laser range sensor Slides adopted from Siegwart

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July 2001. Reprinted from Photonics Spectra, Laurin Publishing

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July 2001. Reprinted from Photonics Spectra, Laurin Publishing Reprint (R22) Avoiding Errors in UV Radiation Measurements By Thomas C. Larason July 2001 Reprinted from Photonics Spectra, Laurin Publishing Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1

More information

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET Centers for Quantitative Imaging Excellence (CQIE) LEARNING MODULE QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET American College of Radiology Clinical Research Center v.1 Centers for Quantitative

More information

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA N. Zarrinpanjeh a, F. Dadrassjavan b, H. Fattahi c * a Islamic Azad University of Qazvin - nzarrin@qiau.ac.ir

More information

Dispersion diagrams of a water-loaded cylindrical shell obtained from the structural and acoustic responses of the sensor array along the shell

Dispersion diagrams of a water-loaded cylindrical shell obtained from the structural and acoustic responses of the sensor array along the shell Dispersion diagrams of a water-loaded cylindrical shell obtained from the structural and acoustic responses of the sensor array along the shell B.K. Jung ; J. Ryue ; C.S. Hong 3 ; W.B. Jeong ; K.K. Shin

More information

Aliasing, Image Sampling and Reconstruction

Aliasing, Image Sampling and Reconstruction Aliasing, Image Sampling and Reconstruction Recall: a pixel is a point It is NOT a box, disc or teeny wee light It has no dimension It occupies no area It can have a coordinate More than a point, it is

More information

Two years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions

Two years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions Two years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions Laurent Desbat TIMC-IMAG, UMR 5525, Grenoble University, France Laurent.Desbat@imag.fr Rolf

More information

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids Principles of Imaging Science II (RAD 120) Radiographic Grids 1 Image-Forming X-Rays Four X-ray paths a. X-rays interact with patient and scatter away from the receptor b. X-rays interact and are absorbed

More information

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim- QUALITY Tissue Benefits Mimicking of s RMI recognized RMI as the ultrasound standard phantoms for quality are performance the ultrasound labs ofand hospitals, manufacturers. clinics Sophisticated and ultrasound

More information

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction Module 1 : Conduction Lecture 5 : 1D conduction example problems. 2D conduction Objectives In this class: An example of optimization for insulation thickness is solved. The 1D conduction is considered

More information

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy Katja Langen, PhD Research supported by TomoTherapy Inc. Today s Lecture Introduction to helical

More information

FURTHER VECTORS (MEI)

FURTHER VECTORS (MEI) Mathematics Revision Guides Further Vectors (MEI) (column notation) Page of MK HOME TUITION Mathematics Revision Guides Level: AS / A Level - MEI OCR MEI: C FURTHER VECTORS (MEI) Version : Date: -9-7 Mathematics

More information

Development of High Speed Oblique X-ray CT System for Printed Circuit Board

Development of High Speed Oblique X-ray CT System for Printed Circuit Board 計 測 自 動 制 御 学 会 産 業 論 文 集 Vol. 6, No. 9, 72/77 (2007) Development of High Speed Oblique X-ray CT System for Printed Circuit Board Atsushi TERAMOTO*, Takayuki MURAKOSHI*, Masatoshi TSUZAKA**, and Hiroshi

More information

Exam 1 Sample Question SOLUTIONS. y = 2x

Exam 1 Sample Question SOLUTIONS. y = 2x Exam Sample Question SOLUTIONS. Eliminate the parameter to find a Cartesian equation for the curve: x e t, y e t. SOLUTION: You might look at the coordinates and notice that If you don t see it, we can

More information

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission Principles of Imaging Science I (RAD119) X-ray Production & Emission X-ray Production X-rays are produced inside the x-ray tube when high energy projectile electrons from the filament interact with the

More information

Resolution Enhancement of Photogrammetric Digital Images

Resolution Enhancement of Photogrammetric Digital Images DICTA2002: Digital Image Computing Techniques and Applications, 21--22 January 2002, Melbourne, Australia 1 Resolution Enhancement of Photogrammetric Digital Images John G. FRYER and Gabriele SCARMANA

More information

INTRODUCTION. A. Purpose

INTRODUCTION. A. Purpose New York State Department of Health Bureau of Environmental Radiation Protection Guide for Radiation Safety/Quality Assurance Programs Computed Radiography INTRODUCTION A. Purpose This guide describes

More information

Robotics. Lecture 3: Sensors. See course website http://www.doc.ic.ac.uk/~ajd/robotics/ for up to date information.

Robotics. Lecture 3: Sensors. See course website http://www.doc.ic.ac.uk/~ajd/robotics/ for up to date information. Robotics Lecture 3: Sensors See course website http://www.doc.ic.ac.uk/~ajd/robotics/ for up to date information. Andrew Davison Department of Computing Imperial College London Review: Locomotion Practical

More information

Cathode Ray Tube. Introduction. Functional principle

Cathode Ray Tube. Introduction. Functional principle Introduction The Cathode Ray Tube or Braun s Tube was invented by the German physicist Karl Ferdinand Braun in 897 and is today used in computer monitors, TV sets and oscilloscope tubes. The path of the

More information

Specific Intensity. I ν =

Specific Intensity. I ν = Specific Intensity Initial question: A number of active galactic nuclei display jets, that is, long, nearly linear, structures that can extend for hundreds of kiloparsecs. Many have two oppositely-directed

More information

ENGINEERING METROLOGY

ENGINEERING METROLOGY ENGINEERING METROLOGY ACADEMIC YEAR 92-93, SEMESTER ONE COORDINATE MEASURING MACHINES OPTICAL MEASUREMENT SYSTEMS; DEPARTMENT OF MECHANICAL ENGINEERING ISFAHAN UNIVERSITY OF TECHNOLOGY Coordinate Measuring

More information

Laue lens for Nuclear Medicine

Laue lens for Nuclear Medicine Laue lens for Nuclear Medicine PhD in Physics Gianfranco Paternò Ferrara, 6-11-013 Supervisor: prof. Vincenzo Guidi Sensors and Semiconductors Lab, Department of Physics and Earth Science, University of

More information

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions Frank N. Ranallo, Ph.D. Associate Professor of Medical Physics & Radiology University of Wisconsin School of

More information

Introduction to CCDs and CCD Data Calibration

Introduction to CCDs and CCD Data Calibration Introduction to CCDs and CCD Data Calibration Dr. William Welsh San Diego State University CCD: charge coupled devices integrated circuit silicon chips that can record optical (and X-ray) light pixel =

More information

Experiment 5. Lasers and laser mode structure

Experiment 5. Lasers and laser mode structure Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,

More information

Radiography: 2D and 3D Metrics of Performance Towards Quality Index

Radiography: 2D and 3D Metrics of Performance Towards Quality Index AAPM COMP 011 Radiography: D and 3D Metrics of Performance Towards Quality Index Ehsan Samei, Sam Richard Duke University Learning objectives Outlook 1. To understand methods for D and 3D resolution measurements..

More information

Measuring of optical output and attenuation

Measuring of optical output and attenuation Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter

More information

BME 501 - Introduction to BME. Bioelectrical Engineering Part: Medical Imaging

BME 501 - Introduction to BME. Bioelectrical Engineering Part: Medical Imaging BME 501 - Introduction to BME Bioelectrical Engineering Part: Medical Imaging Reference Textbook: Principles of Medical Imaging, by Shung, Smith and Tsui Lecturer: Murat EYÜBOĞLU, Ph.D. Dept. of Electrical

More information

Development and quantitative assessment of a beam hardening correction model for preclinical micro-ct

Development and quantitative assessment of a beam hardening correction model for preclinical micro-ct University of Iowa Iowa Research Online Theses and Dissertations 2012 Development and quantitative assessment of a beam hardening correction model for preclinical micro-ct Sucheta Mohapatra University

More information

PHYS 39a Lab 3: Microscope Optics

PHYS 39a Lab 3: Microscope Optics PHYS 39a Lab 3: Microscope Optics Trevor Kafka December 15, 2014 Abstract In this lab task, we sought to use critical illumination and Köhler illumination techniques to view the image of a 1000 lines-per-inch

More information

Sound Power Measurement

Sound Power Measurement Sound Power Measurement A sound source will radiate different sound powers in different environments, especially at low frequencies when the wavelength is comparable to the size of the room 1. Fortunately

More information

IAEA HUMAN HEALTH SERIES

IAEA HUMAN HEALTH SERIES IAEA HUMAN HEALTH SERIES No. 19 Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications IAEA HUMAN HEALTH SERIES PUBLICATIONS The mandate of the IAEA human health programme

More information

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic

More information

Digital radiography conquers the veterinary world

Digital radiography conquers the veterinary world Digital radiography conquers the veterinary world Author: Dirk De Langhe Increasingly, veterinarians are using medical imaging to diagnose their patients. There is a corresponding tendency towards replacing

More information

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Standard Test Method for Classification of Film Systems for Industrial Radiography 1 Designation: E 1815 96 (Reapproved 2001) Standard Test Method for Classification of Film Systems for Industrial Radiography 1 This standard is issued under the fixed designation E 1815; the number immediately

More information