How To Use A Germany Germanysa Germaniesa Gmbo.Com Gmbos System (A/S) With A Power Supply And Power Supply For A Power Source (Power Supply)
|
|
|
- Eleanor Underwood
- 5 years ago
- Views:
Transcription
1 System Manual Access Issue 2011
2 Contents System description Safety remarks 3 System structure, conductor material and range Door area 4 Network LAN 5 Cabling for indoor devices 6 System components Overview 7 Door area 8-11 Indoor devices Distribution Software Licences External devices 21 Installation AS-AV Siedle Vario AS-AV Siedle Vario with external camera AS-AV with Access custom-fit door loudspeaker AS-AV Siedle Steel AS-AV Siedle Vario with DRM AS-AV Siedle Vario with COM AS-AV external camera AS-AA Siedle Vario AS-AA with Access custom-fit door loudspeaker Storey call button, customer s own signalling device Information on programming Initial commissioning/login 43 Servicing 44 LED displays Glossary 48 Index 49 2
3 System description Safety remarks Siedle Access is a powerful communication system based on groundbreaking IP technology. Communication is enabled both for audio and video and also for switching, control and signalling. The ideal field of application for the system is either in large properties or in any type of facility entailing complex technical requirements. Due to the central administration of the entire system, the work involved in commissioning and maintenance is kept to a minimum. The installation is based on network technology, making it extremely open for further expansion. Commercial and private applications can be mixed or combined at will. Technology parks can be connected to administration or training centres under a single cohesive system, even across different buildings, while still retaining their own independent functions. Generally speaking, a distinction is drawn between the door area and the protected local area network (LAN). A detailed description of these two areas is provided in the section System structure / conductor material. Electrical voltage Mounting, installation and servicing work on electrical devices may only be performed by a suitably qualified electrician. Failure to observe this regulation could result in the risk of serious damage to health or fatal injury due to electric shocks. Electrostatic charging As a result of electrostatic charging, direct contact with the circuit board can result in destruction of the device. Direct contact with the circuit board must therefore be avoided. When working at the device, observe the remarks relating to mains cut-off. Observe the DIN EN standard! When establishing the electronic connection, observe the requirements of VDE 0805 or EN The building installation must include an all-pole mains switch with a contact separation of at least 3 mm. Ensure maximum fusing of 16A for the mains connection in the building installation. When planning large-scale (complex) systems, the distributor space required for the switch panel mounting devices must be taken into consideration in the distributor planning process. No external voltages >30 V AC / DC may be applied to system users. Devices with 230 V connection In accordance with DIN VDE 0100 part 410, section attention must be paid to ensuring a safe separation between system lines and the mains voltage; i.e. system and mains cores must not be permitted to touch! The system line cable (extra-low safety voltage) must be stripped back by the minimum possible. During the update process, the power supply to the devices must not be interrupted, as this can result in damage. In this case, a repeat update is no longer possible, and the devices will have to be sent in for repair. 3
4 System structure, conductor material and range Door area Generally speaking, a distinction is drawn between the door area and the protected local area network (LAN). Door area The installation for the door station is referred to as the door area. If correctly installed, this area is protected from unauthorized access. From the outside, it is not possible to access the network. Cabling in the door area The IP network terminates with the ATLC/NG To protect against unauthorized access, the ATLC/NG must be accommodated without fail inside the building. The cabling from the ATLC/ NG to the door station is executed in the conventional way. Conductor material CAT AWG22 J-Y(ST)Y twisted pair conductors, shielded Range Door controller to door station CAT AWG22 = 120 m J-Y(St)Y ø 0,6 mm = 100 m J-Y(St)Y ø 0,8 mm = 200 m Every door station / independent camera is installed in the system with its own ATLC/NG Network LAN ATLC/NG 670 Network LAN ATLC/NG 670 Door area Range depends on the installed conductor material. Camera max. 10 m Door station Tö 4
5 System structure, conductor material and range Network LAN Network LAN The requirement for integration of an Access system is a network infrastructure created in accordance with the stipulations for generic cabling (from CAT5). Rules for generic cabling are set out in various standards: DIN General requirements For individual building types, the following standards apply in addition: DIN (ISO/IEC 11801) for office buildings DIN (ISO/IEC 24702) for industrially used locations DIN (ISO/IEC 15018) for apartments Internationally, the ISO/IEC standards apply. Tertiary area Cabling structure / areas The cabling is broken down into 3 areas. Primary area Fibre optic cables Cabling between individual buildings and/or within buildings between several main building distributors. In the case of copper wire connections, adequate equipotential bonding must be guaranteed. Secondary area Secondary area Fibre optic cables The storeys are networked by means of storey distributors. Both fibre optic and copper connections can be used. This is dependent upon the switches used and their distance from the main distributor / switch. Switch ATLC/NG 670 Server Tertiary area Twisted pair for fixed installation plus patch cable for cabling from the network junction box to the terminal. Door station Tö Primary area 5
6 System structure, conductor material and range Cabling for indoor devices Cabling for indoor devices The Access indoor devices can be installed without problems using standard RJ45 flush mounting network junction boxes. In this case, simply install the network junction box without the frame and panel. The Siedle indoor device can be mounted above the junction box and connected to the network with a plug-in connector. Eye level Junction box RJ45 Eye level If there is no flush mounted network socket at the required mounting height due to circumstances on site, the indoor call station can be surface mounted with the AZA In this case, the connection from the indoor call station to the network is established using a patch cable (not provided). 150 cm 165 cm Junction box RJ cm If the indoor call station is intended for use as a table-top unit, the device can be converted using the AZTV with 3 metre long connecting cable. 6
7 System components Overview Devices integrated in the LAN network (protected area) are linked by an interface to the door. Devices assigned to the door area. AHT AHTV ATLM , ACM , AHF AHFV ATLE , ATLC/NG AIVS AS S AS M, L 7
8 System components Door area ATLM Access door loudspeaker module in 611 Vario design. Complete module with loudspeaker, microphone and light button with LED illuminated light symbol. Up to max. 48 call button modules can be connected in any optional combination, allowing up to max. 192 users. Acoustic feedback when actuating the call button at the BTM to -04 optional. BTM to 04 Bus call button modules BTM with 1, 2, 3 or 4 call buttons. The BTM is connected to the ATLM via ribbon cable. COM Code lock module as an input device for the placement of door calls and control functions in conjunction with Access and the Siedle access control system. With keypad for making calls or For controlling in conjunction with the Easikey controller EC C button for cancelling incorrect inputs DR button for direct door release via the EC DRM Display call module as an input device with 4-line display for placing door calls. Indication of names in the display in alphabetical order. The DRM can also be used in combination with the COM in order to display the input via the COM
9 Siedle Steel STL... Door station with stainless steel front, door loudspeaker, call buttons and Access camera. LED-illuminated bell buttons, 3 ma, 12 V AC each per button. ATLE Access custom-fit door loudspeaker with bus call button matrix for mounting in a loudspeaker compartment, door constructions, letterboxes etc. 12 of the client s own call buttons can be directly connected at the bus call button matrix BRMA Control output for external camera, connection of existing buttons via BRMA BRMA Bus call button matrix for the connection of existing call buttons to the custom-fit door loudspeaker BTLE /ATLE Max. 14 BRMA can be connected to 1 BTLE Max. 16 BRMA can be connected to 1 ATLE
10 System components Door area ACM Access camera module for mounting in Siedle Vario 611-housing. Performance features: Integrated heating with 2-stage temperature control Infrared lighting and control electronics Colour system PAL Image pick-up CCD sensor 8.4 mm (1/3 ) 752 x 582 pixel (horizontal/ vertical) Lens attachment 2.9 mm Automatic day/night switchover at approx. 4 lux (from colour to monochrome) for optimized quality Pick-up angle vertical 60, horizontal 80 Additional mechanical adjustment range 30 horizontal and vertical Horizontal resolution 450 lines CEC Day/night CCD video camera for external mounting, in weather-proof housing and wall arm with ball head, internal cable routing. Image pick-up colour CCD sensor 8.4 mm (1/3 ); 752 (H) x 582 (V) pixel Zoom-lens attachment mm, F 1,2, with IR filter, automatic swivel action Pick-up angle Light sensitivity 0.5 Lux in colour mode and 0.24 Lux in monochrome mode, each at F 1.2 Backlight compensation Automatic white balance Resolution horizontal 480 TV lines Video signal 1 Vpp, FBAS, at 75 Ohm KA/WG C Day/night CCD video camera for external mounting, with weatherproof housing and sun shade, wall arm with ball head and internal wiring. Image pick-up colour CCD sensor 6.3 mm (1/4 ); 752 (H) x 582 (V) 400,000 pixel Lens attachment mm without IR filter Pick-up angle Light sensitivity 0.8 Lux at F 1,2 Resolution horizontal 480 TV lines Video signal 1 Vpp at 75 Ohm Connecting cable in wall arm ZNF Line rectifier foot accessory for the camera KA/WG , for supplying from the 230 V network. The cameras are connected by plugin connections. 10
11 Access Interface Analog-Video Standard AIVS 670 AIVS Access analog video standard interface in surface-mount housing for connection of an analog camera to the ATLC Following a door call, the picture from the analog camera automatically appears on the Access indoor call station. Manual selection of the door is also possible. The camera cannot be controlled. The connection of analogue cameras generally takes place via the Access interface analogue-video standard AIVS
12 System components Indoor devices, Accessory AHT Access in-house telephone with door release button and 7 additional buttons with 2-colour status LED. All buttons are freely programmable. The display shows the graphic menu interface, but not a camera image. It is possible to upgrade to a fully functional video station. With the functions calling, speech, door release, light, remote switching and call silencing. With the additional purchase of licence ALUV , the AHT can be converted into a fully functional indoor video device. Performance features: Display 8.8 cm Entrance for storey calls Exit freely programmable Call differentiation between door calls, storey calls, indoor calls and concierge calls Switching functions Status indications Can be used with table-top accessory AZTV as a table-top device AHF Access handsfree telephone with speech / control button, door release button and 7 additional buttons with 2-colour status LED. All buttons are freely programmable. The display shows the graphic menu interface, but not a camera image. It is possible to upgrade to a fully functional video station. With the functions calling, speech, door release, light, remote switching and call silencing. With the additional purchase of licence ALUV the AHF can be converted into a fully functional indoor video device. Performance features: Display 8.8 cm Entrance for storey calls Exit freely programmable Call differentiation between door calls, storey calls, indoor calls and concierge calls Switching functions Status indications Can be used with table-top accessory AZTV as a table-top device AHTV Access in-house telephone video with door release button and 7 additional buttons with 2-colour status LED. All buttons are freely programmable. The display shows the camera image and the graphic menu interface. With the functions calling, speech, door release, vision, light, remote switching and call silencing. Performance features: Display 8.8 cm Entrance for storey calls Exit freely programmable Call differentiation between door calls, storey calls, indoor calls and concierge calls Switching functions Status indications Video memory function over licence ALZV Integrated 5-way control button for operation of the video memory, brightness, colour saturation etc. Can be used with table-top accessory AZTV as a table-top device 12
13 AHFV Access handsfree telephone video with speech / control button, door release button and 7 additional buttons with 2-colour status LED. All buttons are freely programmable. The display shows the camera image and the graphic menu interface. With the functions calling, speech, door release, vision, light, remote switching and call silencing. Performance features: Display 8.8 cm Entrance for storey calls Exit freely programmable Call differentiation between door calls, storey calls, indoor calls and concierge calls Switching functions Status indications Video memory function over licence ALZV Integrated 5-way control button for operation of the video memory, brightness, colour saturation etc. Can be used with table-top accessory AZTV as a table-top device AZA Access surface-mount accessory, for professional surface mounting of Access indoor call stations. Comprises a connection adapter and 4 spacers. The raised height is increased by 8 mm. Top Oben AZIO Access input/output accessory as circuit board for integration in an indoor unit with an additional output/input. AZTV Access table-top accessory for indoor call stations for converting from a wall to a table-top device. Slip-proof console. 13
14 System components Distribution ATLC/NG Access door loudspeaker controller with line rectifier in switch panel housing as an interface for the connection and power supply of door components to the Access network. Switch contact for door release and freely programmable switching input. Admissible switching output: Light bulbs max W Fluorescent lamps max. 800 W Twin fluorescent lamps max W Parallel compensated fluorescent lamps max. 400 W VNG Video line rectifier in a 10-grid housing. Primary: 230 V AC, 50/60 Hz Secondary: 30 V DC, 1.1 A stabilized. For the supply of individual components such as external cameras. TR Transformer in switch panel housing, to supply supplementary components. Operating voltage: 230 V AC +/-10%, 50/60 Hz Output voltage: 12 V AC Output current: max. 2.5 A Dimensions (mm) W x H x D: 107 x 89 x 60 TR Transformer in switch panel housing, to supply supplementary components. Operating voltage: 230 V AC +/-10%, 50/60 Hz Output voltage: 12 V AC Output current: max. 1.3 A Dimensions (mm) W x H x D: 53.5 x 89 x 60 14
15 AS S Access Server in metal housing, suitable for top hat rail mounting, as a central unit for management of the entire Access system; Expansion possible up to 50 users. More than 10 connections may exist at any one time in the system. Commissioning takes place in the complete system. Dimensions (mm) W x H x D: 328 x 88.8 x 201 AS M Access server in 19 housing as a central unit for managing the entire Access system. Expansion possible up to 500 users. More than 10 connections may exist at any one time in the system. Commissioning takes place in the complete system. Dimensions (mm) W x H x D: 483 x 88 x 460 AS L Access server in 19 housing as a central unit for managing the entire Access system. Expansion possible from 500 to over 1000 users. More than 10 connections may exist at any one time in the system. Commissioning takes place in the complete system. Dimensions (mm) W x H x D: 483 x 88 x
16 Software ASHT Access Software Concierge S. Siedle & Söhne Furtwangen ASHT Access in-house telephone software, which graphically depicts a virtual in-house telephone with video on a PC monitor. Door calls with video are possible to a Siedle door station. Indoor calls possible Execution of switching and control functions such as door release, light switching etc. Display of signals Function overview: Call differentiation between door calls, storey calls, indoor calls and concierge calls Device and user overview Users, doors and devices can be selected from lists Global / private address books Video memory function over licence ALZV Status displays of switchgear Switching functions for external relays System requirements: Microsoft Windows XP (from SP3, 32 Bit) Microsoft Windows Vista Home Premium and Business (from SP1, 32/64 Bit) Microsoft Windows 7 Home Premium, Professional and Ultimate (32/64 Bit) Intel Pentium IV from 2.0 GHz or compatible CPUs min. 2 GB RAM Graphics card with at least 128 MB RAM DirectX 9 support and 16 bit colour depth Ethernet card 100 Mbit Sound card including headset adapter.net Framework
17 ASC Access Software Concierge ASM Access Software Modul S. Siedle & Söhne Furtwangen S. Siedle & Söhne Furtwangen ASC Access concierge software, the central interface at the reception desk. Due to the wide selection of possible control functions and statuses, and facility for supporting several calls and video links, this application is ideally suited as a communication switchboard. Function overview: Several audio and video links can be depicted simultaneously Convenient forwarding functions Music-on-hold Status overview of all Doormatic door statuses, e.g. activation enabled day/night switchover Convenient switching/control and display functions Camera scan function Answering machine functions System requirements: Microsoft Windows XP (from SP3, 32 Bit) Microsoft Windows Vista Home Premium and Business (from SP1, 32/64 Bit) Microsoft Windows 7 Home Premium, Professional and Ultimate (32/64 Bit) Intel Pentium IV from 2.0 GHz or compatible CPUs min. 2 GB RAM Graphics card with at least 1280 x 720, 128 MB RAM, DirectX 9 support and 16 bit colour depth Ethernet card 100 Mbit Sound card including headset adapter.net Framework 4.0 ASM Access software module for integration of Siedle Access in external systems, e.g. touch panels. You will be kept up to date with the latest information by our Project Sales Department 17
18 Licences ALUV Access video upgrade licence subsequently enables the video function in an audio device. This licence encompasses the upgrade for a device. ALZA Access additional admin licence to create additonal administrators with different authorization levels. The number is only limited by the server. ALT Access telephony connection licence for utilization of an external connection channel. A separate licence is required per channel. The use of non-siedle devices is subject to Siedle approval. ALFV Access licence for non-siedle video device for connection of a VoIP video telephone to the Access system. The use of non-siedle devices is subject to Siedle approval. ALFA Access licence for non-siedle audio device for connection of a VoIP audio telephone to the Access system. Using a VoIP-ATA adapter, it is also possible to connect an analog telephone. The use of non-siedle devices is subject to Siedle approval. ALFC Access licence for non-siedle IP camera for connection of a network camera to the Access system. The use of non-siedle devices is subject to Siedle approval. ALFIO Access licence for non-siedle IP control unit for managing the inputs and outputs of an external control unit in the system. A separate licence is required in the system per control unit. The use of non-siedle devices is subject to Siedle approval. ALFS The external smartphone Access licence permits connection to the Access server. A separate licence is required per device. The smartphone functions as a mobile indoor device with video. An additional App is required for operation. This must be purchased from the App Store. ALFT The external tablet Access licence permits connection to the Access server. A separate licence is required per device. The tablet functions as a mobile indoor device with video. An additional App is required for operation. This must be purchased from the App Store. 18
19 ALKNX <50 Access KNX connection licence for importing and managing KNX addresses. A maximum of 50 data points can be assigned. KNX telegrams can be sent and received. ALKNX <300 Access KNX connection licence for importing and managing KNX addresses. A maximum of 300 data points can be assigned. KNX telegrams can be sent and received. ALKNX >300 Access KNX connection licence for importing and managing KNX addresses. Any optional number of data points can be assigned. KNX telegrams can be sent and received. ALSP S The Access licence starter pack includes the licences ALN/ALZV/ ALZA/ALT. This collection allows wide-ranging additional functionally for your Access system. The starter pack can only be used on an Access Server S. 19
20 Licences ALN S ALN M ALN L Access message function licence for receiving texts and listening to stored messages. At the device, it is possible to record, save and play back messages. The integrated answering machine accepts external calls and records them. The size of the installed server determines the licence. ALZV S ALZV M ALZV L Access additional video functionality licence is an extension to include further-reaching video functions such as the video memory function at all indoor call stations. Function scope: Event-based camera connection, e.g. movement sensor module switches the relevant video camera and the camera image is saved Scan functionality of the existing video cameras to all indoor devices The size of the installed server determines the licence. Licences and servers must always be in agreement. Example: Only one S licence can be entered for one AS S server. 20
21 External devices For many requirements and ideas, the market is flooded by a large number of devices. Communication and compatibility between the different components can sometimes be an issue. For this reason, it is advisable to make contact at an early stage with our project sales department. We are currently able to offer recommendations for the following areas. Analogue telephone adapter ATA SIP telephone Switch actuators KNX VoIP Interface ISDN telephone system If required, we are glad to also test other interesting areas. 21
22 Installation AS-AV Siedle Vario ATLM BTM V2 V1 Ta V3 Tb Ta V4 Tb Ta V5 V6 V6 V5 c1 b1 Ta Tbb Ta V1 Tb Ta V2 Tb Tb S1 Ta Tb S2 Ta S3 S4 D1 D2 Siedle Vario ACM ATLM BTM V1 V2 S1 Ta Tb S2 Ta S3 Ta S4 Ta D1 Tb D2 Ta 230 V AC Tö 12 V AC min. 20 Ohm c b N N L1 L1 230 V AC ACM IN Device requirement Remarks Tb Ta c TR ANG g), k) ATLC a) LAN 22
23 Functional Calling, speech and video functions between door station and the connected Access indoor call stations. An existing call can not be listened in to or viewed by other Access indoor call stations. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The definition of functions and the relevant buttons take place during configuration of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server. Connection facility for a storey call button (ERT) for calling an apartment door and potential-free contact is available as standard. Different ringtones for calling from the front door, the apartment door, concierge or internal call. Supplementary functions Internal calls and speech communication between Access indoor call stations are possible. Connection of an analogue camera to the ATLC 670- via the interface AIVS Concierge function as central interface, e.g. at the reception 8 freely selectable ring tones Call forwarding Call follow-me function Parallel door and storey call Group formation possible Selective dialling of the door station using additional free buttons Scan function (licence-dependent) Central video memory module (server) possible Supplementary functions available with the relevant licences Access additional video functionality licence is an extension to include further-reaching video functions such as the video memory function at all indoor call stations. Function scope: Event-based camera connection, e.g. movement sensor module switches the relevant video camera and the camera image is saved Scan functionality of the existing video cameras to all indoor devices Access prioritized message licence to signal events acoustically and optically. These messages are prioritized over all existing connections. Access system monitoring licences for monitoring cables and terminals. Error messages, status messages and reports about the system status are sent by . Access message function licence for receiving texts and listening to stored messages. At the device, it is possible to record, save and play back messages. The integrated answering machine accepts external calls and records them. The size of the installed server determines the licence. Remarks a) If door release or door control systems are installed which do not correspond to 12 V AC min. 20 Ohm, the system will require an intermediate relay. g) Is only required if more than 10 BTM units are installed at this door station. k) If the BTM 650- units are supplied via a separate transformer, no connection between c1 and c / b1 and b may exist at the terminal block. 23
24 Installation AS-AV Siedle Vario with external camera ATLM BTM S1 Ta S2 Ta S3 Tb S4 D1 Ta D2 Tb Ta V5 V6 b c Siedle Vario ATLM BTM V1 V2 Ta V3 Tb Ta V4 Tb Ta V5 V6 L/S L/S +K S5 -K S7 b c + - N L1 ANG S1 Ta S2 Ta Tb S3 S4 D1 Ta D2 Tb Ta V1 Tb V ATLC V AC 230 V AC IN Device requirement Remarks Tö 12 V AC min. 20 Ohm CEC AIVS b) c) N L1 TR g), k) a) LAN 24
25 Functional Calling and speech between door stations and the connected Access indoor call stations. The external camera discreetly surveys the access area from the background. An existing call can not be listened in to or viewed by other Access indoor call stations. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The definition of functions and the relevant buttons take place during configuration of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server. Connection facility for a storey call button (ERT) for calling an apartment door and potential-free contact is available as standard. Different ringtones for calling from the front door, the apartment door, concierge or internal call. Supplementary functions Internal calls and speech communication between Access indoor call stations are possible. Connection of an analogue camera to the ATLC 670- via the interface AIVS Concierge function as central interface, e.g. at the reception 8 freely selectable ring tones Call forwarding Call follow-me function Parallel door and storey call Group formation possible Selective dialling of the door station using additional free buttons Scan function (licence-dependent) Central video memory module (server) possible Supplementary functions available with the relevant licences Access additional video functionality licence is an extension to include further-reaching video functions such as the video memory function at all indoor call stations. Function scope: Event-based camera connection, e.g. movement sensor module switches the relevant video camera and the camera image is saved Scan functionality of the existing video cameras to all indoor devices Access prioritized message licence to signal events acoustically and optically. These messages are prioritized over all existing connections. Access system monitoring licences for monitoring cables and terminals. Error messages, status messages and reports about the system status are sent by . Access message function licence for receiving texts and listening to stored messages. At the device, it is possible to record, save and play back messages. The integrated answering machine accepts external calls and records them. The size of the installed server determines the licence. Remarks a) If door release or door control systems are installed which do not correspond to 12 V AC min. 20 Ohm, the system will require an intermediate relay. b) Distance between the camera and AIVS max. 10 m c) Pay attention to the switch setting for the supply voltage 12/24 V DC g) Is only required if more than 26 BTM units are installed at this door station. k) If the BTM 650- units are supplied via a separate transformer, no connection between c1 and c / b1 and b may exist at the terminal block. 25
26 Installation AS-AV with Access custom-fit door loudspeaker ATLE BRMA V5 c Tö 12 V AC min. 20 Ohm L/S L/S +K S5 -K S7 b) c) ATLC V AC IN Device requirement Remarks S1 S2 S3 S4 D1 D2 Custom-fit door loudspeaker ATLE BRMA d) V1 V2 V3 V4 V5 V6 CEC AIVS N L1 ANG S1 S2 S3 S4 D1 D2 V1 V a) LAN 26
27 Functional Calling and speech between door stations and the connected Access indoor call stations. The external camera discreetly surveys the access area from the background. An existing call can not be listened in to or viewed by other Access indoor call stations. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The definition of functions and the relevant buttons take place during configuration of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server. Connection facility for a storey call button (ERT) for calling an apartment door and potential-free contact is available as standard. Different ringtones for calling from the front door, the apartment door, concierge or internal call. Supplementary functions Internal calls and speech communication between Access indoor call stations are possible. Connection of an analogue camera to the ATLC 670- via the interface AIVS Concierge function as central interface, e.g. at the reception 8 freely selectable ring tones Call forwarding Call follow-me function Parallel door and storey call Group formation possible Selective dialling of the door station using additional free buttons Scan function (licence-dependent) Central video memory module (server) possible Supplementary functions available with the relevant licences Access additional video functionality licence is an extension to include further-reaching video functions such as the video memory function at all indoor call stations. Function scope: Event-based camera connection, e.g. movement sensor module switches the relevant video camera and the camera image is saved Scan functionality of the existing video cameras to all indoor devices Access prioritized message licence to signal events acoustically and optically. These messages are prioritized over all existing connections. Access system monitoring licences for monitoring cables and terminals. Error messages, status messages and reports about the system status are sent by . Access message function licence for receiving texts and listening to stored messages. At the device, it is possible to record, save and play back messages. The integrated answering machine accepts external calls and records them. The size of the installed server determines the licence. Remarks a) If door release or door control systems are installed which do not correspond to 12 V AC min. 20 Ohm, the system will require an intermediate relay. b) Distance between the camera and AIVS max. 10 m c) Pay attention to the switch setting for the supply voltage 12/24 V DC d) A maximum of 12 call buttons can be connected at one BRMA The maximum configuration is 16 BRMA units / 192 buttons. 27
28 Installation AS-AV Siedle Steel SACM SATLM V1 Tb Ta V2 Tb Tb S1 Ta Tb S2 Ta S3 S4 D1 D2 V1 V2 S1 Ta Tb S2 Ta S3 Ta S4 Ta D1 Tb D2 Ta 23 Tö 12 V AC min. 20 Ohm 24 Buttons N L1 230 V AC LAN Device requirement Siedle Steel SACM SATLM ANG ATLC Remarks a) 28
29 Functional Calling, speech and video functions between door station and the connected Access indoor call stations. An existing call can not be listened in to or viewed by other Access indoor call stations. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The definition of functions and the relevant buttons take place during configuration of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server. Connection facility for a storey call button (ERT) for calling an apartment door and potential-free contact is available as standard. Different ringtones for calling from the front door, the apartment door, concierge or internal call. Supplementary functions Internal calls and speech communication between Access indoor call stations are possible. Connection of an analogue camera to the ATLC 670- via the interface AIVS Concierge function as central interface, e.g. at the reception 8 freely selectable ring tones Call forwarding Call follow-me function Parallel door and storey call Group formation possible Selective dialling of the door station using additional free buttons Scan function (licence-dependent) Central video memory module (server) possible Supplementary functions available with the relevant licences Access additional video functionality licence is an extension to include further-reaching video functions such as the video memory function at all indoor call stations. Function scope: Event-based camera connection, e.g. movement sensor module switches the relevant video camera and the camera image is saved Scan functionality of the existing video cameras to all indoor devices Access prioritized message licence to signal events acoustically and optically. These messages are prioritized over all existing connections. Access system monitoring licences for monitoring cables and terminals. Error messages, status messages and reports about the system status are sent by . Access message function licence for receiving texts and listening to stored messages. At the device, it is possible to record, save and play back messages. The integrated answering machine accepts external calls and records them. The size of the installed server determines the licence. Remarks a) If door release or door control systems are installed which do not correspond to 12 V AC min. 20 Ohm, the system will require an intermediate relay. 29
30 Büchner Claudia Maier Klaus Schuhmacher Bernd Namensuche mit Büchner Claudia Maier Klaus Schuhmacher Bernd Namensuche mit Installation AS-AV Siedle Vario with DRM V2 ACM ATLM V1 Ta V3 Tb Ta V4 Tb Ta V5 V6 V6 V5 c1 Ta c Tb b1 Ta Tbb Ta V1 Tb Ta V2 Tb Tb S1 Ta Tb S2 Ta S3 S4 D1 D2 Tö 12 V AC min. 20 Ohm V1 V2 S1 Ta Tb S2 Ta S3 Ta S4 Ta D1 Tb D2 Ta IN BTM Db DRM Da cv bv N L1 230 V AC LAN Device requirement Siedle Vario ACM ATLM BTM DRM ANG ATLC Remarks h) a) 30
31 Functional Calling, speech and video functions between door station and the connected Access indoor call stations. With the call button module, the call goes to a central location (concierge) or via the display call module selectively to the required user. An existing call can not be listened in to or viewed by other Access indoor call stations. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The definition of functions and the relevant buttons take place during configuration of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server. Connection facility for a storey call button (ERT) for calling an apartment door and potential-free contact is available as standard. Different ringtones for calling from the front door, the apartment door, concierge or internal call. Supplementary functions Internal calls and speech communication between Access indoor call stations are possible. Connection of an analogue camera to the ATLC 670- via the interface AIVS Concierge function as central interface, e.g. at the reception 8 freely selectable ring tones Call forwarding Call follow-me function Parallel door and storey call Group formation possible Selective dialling of the door station using additional free buttons Scan function (licence-dependent) Central video memory module (server) possible Supplementary functions available with the relevant licences Access additional video functionality licence is an extension to include further-reaching video functions such as the video memory function at all indoor call stations. Function scope: Event-based camera connection, e.g. movement sensor module switches the relevant video camera and the camera image is saved Scan functionality of the existing video cameras to all indoor devices Access prioritized message licence to signal events acoustically and optically. These messages are prioritized over all existing connections. Access system monitoring licences for monitoring cables and terminals. Error messages, status messages and reports about the system status are sent by . Access message function licence for receiving texts and listening to stored messages. At the device, it is possible to record, save and play back messages. The integrated answering machine accepts external calls and records them. The size of the installed server determines the licence. Remarks a) If door release or door control systems are installed which do not correspond to 12 V AC min. 20 Ohm, the system will require an intermediate relay. h) Where there are more than one BTM , an additional 12 V AC supply, for instance TR , must be installed due to the current consumption. 31
32 Büchner Claudia Maier Klaus Schuhmacher Bernd Namensuche mit Installation AS-AV Siedle Vario with COM V2 ACM ATLM V1 Ta V3 Tb Ta V4 Tb Ta V5 V6 V6 V5 c1 Ta c Tb b1 Ta Tbb Ta V1 Tb Ta V2 Tb Tb S1 Ta Tb S2 Ta S3 S4 D1 D2 Da Ta Db Ta V1 V2 S1 Ta Tb S2 Ta S3 Ta S4 Ta D1 Tb D2 Ta IN BTM W2 14 COM Db Da cv bv Tö 12 V AC min. 20 Ohm c b N L1 230 V AC W0 Ta Tac Tbb Ta N L1 230 V AC 13 LAN Device requirement Siedle Vario ACM ATLM BTM COM TR EC ANG ATLC Remarks d) i), k) a) 32
33 Functional Calling, speech and video functions between door station and the connected Access indoor call stations. With the call button module, the call goes to a central location (concierge) or via the code lock module selectively to the user whose stored code you have entered. An existing call can not be listened in to or viewed by other Access indoor call stations. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The definition of functions and the relevant buttons take place during configuration of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server. Connection facility for a storey call button (ERT) for calling an apartment door and potential-free contact is available as standard. Different ringtones for calling from the front door, the apartment door, concierge or internal call. Supplementary functions Internal calls and speech communication between Access indoor call stations are possible. Connection of an analogue camera to the ATLC 670- via the interface AIVS Concierge function as central interface, e.g. at the reception 8 freely selectable ring tones Call forwarding Call follow-me function Parallel door and storey call Group formation possible Selective dialling of the door station using additional free buttons Scan function (licence-dependent) Central video memory module (server) possible Supplementary functions available with the relevant licences Access additional video functionality licence is an extension to include further-reaching video functions such as the video memory function at all indoor call stations. Function scope: Event-based camera connection, e.g. movement sensor module switches the relevant video camera and the camera image is saved Scan functionality of the existing video cameras to all indoor devices Access prioritized message licence to signal events acoustically and optically. These messages are prioritized over all existing connections. Access system monitoring licences for monitoring cables and terminals. Error messages, status messages and reports about the system status are sent by . Access message function licence for receiving texts and listening to stored messages. At the device, it is possible to record, save and play back messages. The integrated answering machine accepts external calls and records them. The size of the installed server determines the licence. Remarks a) If door release or door control systems are installed which do not correspond to 12 V AC min. 20 Ohm, the system will require an intermediate relay. d) The COM is always available for placing calls (by code). An additional Easikey controller is only required for this door station if additional control functions have to be carried out. i) This is required with the EC 602- or when more than one BTM 650- is installed in the door station. k) If the BTM 650- units are supplied via a separate transformer, no connection between c1 and c / b1 and b may exist at the terminal block. 33
34 Installation AS-AV external camera V4 Tb Ta V6 V5 L/S L/S +K S5 -K S7 a) b) ATLC V AC Device requirement Remarks V1 V2 Ta V3 Tb Ta CEC AIVS N L1 ANG V1 Tb V LAN 34
35 Functional Viewing / monitoring a certain area using an Access indoor call station set up for the purpose. Each camera is specifically selected via the ATLC The number of cameras / Access users is limited by the server used. Using the buttons defined during configuration, each camera can be selected. This function must be configured for every authorized user. Remarks a) Distance between the camera and AIVS max. 10 m b) Pay attention to the switch setting for the supply voltage 12/24 V DC 35
36 Installation AS-AA Siedle Vario ATLM BTM S1 S2 S3 S4 D1 D2 b1 c1 c b Siedle Vario ATLM BTM N L1 S1 S2 S3 S4 D1 D ATLC V AC IN Device requirement Remarks j) Tö 12 V AC min. 20 Ohm ANG a) LAN 36
37 Functional Calling and speech between door stations and the connected Access indoor call stations. Other Access indoor call stations are not able to listen in to an existing call. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The definition of functions and the relevant buttons take place during configuration of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server. Connection facility for a storey call button (ERT) for calling an apartment door and potential-free contact is available as standard. Different ringtones for calling from the front door, the apartment door, concierge or internal call. Remarks a) If door release or door control systems are installed which do not correspond to 12 V AC min. 20 Ohm, the system will require an intermediate relay. j) From 26 BTM units, an additional 12 V AC, for instance TR must be installed due to the current consumption. 37
38 Installation AS-AA with Access custom-fit door loudspeaker ATLE BRMA S1 S2 S3 S4 D1 D2 D2 23 S1 S2 S3 S4 D1 Tö 12 V AC min. 20 Ohm V AC IN Device requirement Remarks N L1 Bus custom-fit door loudspeaker ATLE BRMA ANG ATLC d) a) LAN 38
39 Functional Calling and speech between door stations and the connected Access indoor call stations. Other Access indoor call stations are not able to listen in to an existing call. Door release button for the door release function and 7 other buttons which can be assigned any optional functions. The definition of functions and the relevant buttons take place during configuration of the server which assumes the function of central overall system administrator. The number of Access users is determined by the server. Connection facility for a storey call button (ERT) for calling an apartment door and potential-free contact is available as standard. Different ringtones for calling from the front door, the apartment door, concierge or internal call. Remarks a) If door release or door control systems are installed which do not correspond to 12 V AC min. 20 Ohm, the system will require an intermediate relay. d) A maximum of 12 call buttons can be connected at one BRMA The maximum configuration is 16 BRMA units / 192 buttons. 39
40 Installation Storey call button, customer s own signalling device Ta 6 3 Ta 5 ERT Tb4 LAN Device requirement RJ45 8/8 Remarks e) Ta Ta 6 3 Ta 5 Tb 4 ERT LAN Device requirement RJ45 8/8 Remarks e), f) 40
41 Functional A storey call button can be connected as standard to every Access indoor call station. To guarantee call differentiation between door and storey calls, a different acoustic signal is issued for the storey call. The selection of signals is defined by the administrator during configuration. The storey call button is connected via the RJ45 8/8 telecom socket. The left-hand jack is generally used for the LAN network. The storey call button and if applicable the customer s own existing signalling device are connected using the right-hand jack. Remarks e) A suitable intermediate relay may be required for the customer s own existing signalling device. f) By mounting accessory AZIO terminals 1 and 2 as well as 7 and 8 of the right-hand RJ45 telecom socket are occupied, as listed in the terminal assignment. The terminal assignment changes if a different accessory is mounted. Terminal assignment Link RJ45 socket 1-8 LAN Right RJ45 socket 3 Storey call button ERT Switching contact 30 V, 1 A Input via potential-free contact Switching contact 30 V, 1 A 41
42 Information on programming The Access system is programmed using an IBM-compatible PC at the server. The necessary programming software is included in the scope of delivery and already installed on the server. Any necessary support for programming-related questions can be found in the help function. Careful documentation of the system and any configuration-related requirements with an indication of the device mounting locations is particularly helpful and should be made a constituent part of the operating manual without fail. Operating manual To ensure that you can retrace the status of a system at any time, an operating manual should be drawn up and regularly maintained. Siedle recommends compiling an operating manual to document the network and the Access system. The operating manual must be accessible to servicing personnel and contain fundamental information: Contact data of the system administrator (with deputization arrangements) Hardware list Documentation of the server configuration Server backup Documentation of the software status and device configuration Construction plan with structured cabling (LAN policy) Issue of passwords and possibilities for remote login access IP address and device names of the network components Process descriptions (e.g. creating a user, exchanging devices etc.) Documentation of changes made Documentation of errors / remedy of errors Licence management Through the purchase of additional licences, more services can be purchased for specific devices or for the system as a whole. These can be purchased exclusively through our Access Certified Partners, who will then enable the licences for you. To find the responsible Access Certified Partner, go to 42
43 Initial commissioning/login Requirements: PC with installed browser (Firefox, latest version) The PC and Access Server must be in the same network / linked using a crossover cable Registration at the administrator user interface Login via a web interface takes place on the Access server. For this, enter the IP address of the server. This is defined as in the asdelivered status. The administrator set in the factory has the account name admin and the password admin. In addition, a randomly generated security code is required with each login. This is entered in the security code field. If the security code is not legible, click onto it to generate a new code. Start the login process using the login button. Further configuration is prompted by the server instructions and using the integrated help function. Kontoname Kennwort Sicherheitscode admin hsnc hsnc Anmelden Abbrechen 43
44 Servicing Service requirement Access systems are serviced by the regional Access Certified Partner (service specialists). Customers / administrators request this services as the need arises. For services specialists, access must be afforded to all parts of the system at all times. The administrator and all necessary documents appertaining to the system must be available for the duration of the servicing work. Safety remarks Mounting, installation and servicing work on electrical devices may only be performed by a suitably qualified electrician. Failure to observe this regulation could result in the risk of serious damage to health or fatal injury due to electric shocks. Electrical voltage As a result of electrostatic charging, direct contact with the circuit board can result in destruction of the device. Direct contact with the circuit board must therefore be avoided. Exchanging devices All devices which are connected directly to the network (supplied via POE) can be exchanged in running operation. Procedure: The administrator overwrites the MAC address for the device being exchanged by the MAC address of the new replacement device. Exchange the defective device. The configuration remains unchanged, making the function identical with the predecessor device. Exchanging ATLM/ATLE Procedure: Only the line rectifier which supplies the ATLC has to be disconnected from the mains. The Access system can remain operational. Exchange the defective ATLM/ ATLE Switch the line rectifier back on. The system is now completely ready to resume operation. No configuration is required. Exchanging a defective server AS Procedure: Sever all connections to the mains and the power supply. Exchange the defective server and restore all the connections Set up the supplied licences on the new server Restore the backup of the current configuration. If no backup exists, the system must be reconfigured. Update process The update is initialized by the administrator and centrally executed at the server for all the devices. It is not possible to carry out an individual update of a single internal device or the server. During the update process, the entire system is non-operational. No calls or functions can be initiated or received. Updates should therefore be carried out during periods of minimal activity and with sufficient advance notice. The update operation of the internal devices is optically displayed by all the buttons lighting up in yellow. After the update is complete, the devices are automatically restarted. During the update process, the power supply to the devices must not be interrupted, as this can result in damage. In this case, a repeat update is no longer possible, and the devices will have to be sent in for repair. 44
45 Start process The start process can be initiated centrally by the administrator at the server. Unplugging and reconnecting the internal devices also initiates a restart. The Access door loudspeaker controller can be restarted by briefly disconnecting the relevant line rectifier or by actuating the reset button. The reset button can only be accessed by opening the housing. A restart of the internal devices is signalled by a yellow flashing light, starting with button 8 and ending with button 6, and the display lights up in white. If the start is successful and when the device has received all the information from the server, the system goes to the operating status. In the event of a fault, e.g. the internal device is not configured, all the buttons light up continuously in red. 45
46 LED displays LED S1 S2 S3 S4 D1 D2 V1 V2 Output Input ATLM/ACM ATLC Access Türlautsprecher-Controller Access Door loudspeaker controller Access Contrôleur de platine de rue IP 20 Link Status Error / OK A1 A2 A3 E SN ATLC LED display LED operating status Function LED 1 off no operating voltage lights up in green operating voltage applied Link lights up in green connection to switch exists flashes green data communication with the device off no connection to the switch Status lights up in green Vario bus ready for operation flashes green data communication in the Vario bus Error/OK lights up briefly in green after Power On for around 5 secs. flashes green during ramp-up, flashing starts up appr. 20 secs. after Power On lights up in green ATLC is logged in at the server lights up in red error logging into server A1 lights up in green output 1 HIGH (DR) off output 1 LOW (DR) A2 lights green output 2 HIGH off output 2 LOW A3 lights up in green output 3 HIGH (LI) off output 3 LOW E lights up in green input 1 HIGH (LI) off input 1 LOW 46
47 LED 1 LED 1 LED 5 LED 8 LED 4 LED 8 LED 1 AHTV/AHFV LED display LED operating status Function LED 8 flashes yellow Searching for the server off server found LED 7 flashes yellow loading configuration from server off export successfully completed LED 6 flashes yellow login to server off login successful LED 1-8 lights up briefly in yellow after Power On for around 5 secs. lights up in red error logging into server off successfully logged into server ATLM LED display LED operating status Function LED 1 flashes green device startup off startup successfully completed lights up green audio active flashes briefly in green call button is actuated lights up in red error logging into server 47
48 Glossary Telecom socket RJ45 8/8 The left-hand jack is used for the LAN network. The storey call button and if applicable the customer s own existing signalling device are connected using the right-hand jack. Software The system software is pre-installed on the server. The software for the concierge and virtual telephone functions or for connection to external systems must be additionally purchased if required. Operating manual Current system documentation including all hardware and software requirements. CAT5 Twisted pair cable, shielded Storey call button The storey call button (ERT) is used to call from a storey door to the internal device. Indoor devices Call stations and accessories as an intercom to the door area. LAN Local Area Network Network which connects the system components. Licences Enabling performance characteristics which are additionally managed centrally on the server. Switch Coupling element which links the network components and segments. Door area In the door area are all devices connected to the system via an Access door loudspeaker controller ATLC This also includes cameras which monitor different areas. Doormatic Programmable function which actuates a contact in the ATLC with a time delay (door release). Distribution This is the place where several devices are switched together (connected). This often takes place in a distributor cabinet, although this is not mandatory. Large distribution panels can fill an entire room. POE Power over Ethernet supplies all internal devices. System components All devices which are connected together in the system. 48
49 Index ACM , 22 AHF AHFV AHT AHTV AIVS ALFA ALFC ALFIO ALFV ALKNX ALN ALPM ALS ALT ALUV ALZA ALZV ANG AS ASC ASHT ASM ATLC ATLC/NG ATLE , 26, 40 ATLM AZA AZIO AZTV BTM CEC , 24, 36 COM , 32 DRM , 32 KA/WG Siedle Steel 9, 28 TR TR Technical additions or printing errors do not constitute grounds for compensation claims. After-sales service: Telephone [email protected] To supplement this system manual, you will find the latest edition in the download area of our website on 49
50 50
51 51
52 S. Siedle & Söhne Telefon- und Telegrafenwerke OHG Postfach Furtwangen Bregstraße Furtwangen 2011/08.12 Printed in Germany Best. Nr / EN Telefon Telefax [email protected]
System Manual 1+n technology Issue 2013
System Manual 1+n technology Issue 2013 Contents 1 1+n technology System description 3 2 Safety remarks 3 3 Configuration, conductor lengths 1+n technology 4-5 Overview 6 4 Device overview Door loudspeakers,
System Manual 1+n technology
System Manual 1+n technology Contents 1 1+n technology System description 3 2 Safety remarks 3 3 Configuration, conductor lengths 1+n system without video 4-5 1+n system with video 6-7 Overview 8 4 Device
Getting connected. Door communication and access control in the IP network
Getting connected Door communication and access control in the IP network 3 Door communication and access control in the IP network Siedle links IP networks with building communication and access control.
BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.
BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door
Manual DoorCom IP DCIP 650-0
Manual DoorCom IP DCIP 650-0 Contents 1 System description 3 2 Safety remarks 3 System requirements 3 3 Structure DCIP 650-... 4 DCIP 650-... with DCA 740-... 5 Terms 6 4 Components DoorCom IP Door loudspeakers,
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS
AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS 1 DORANI VIDEO INTERCOM - 2 WIRE SERIES 7 TFT MONITOR TECHNICAL SPECIFICATIONS 7 Colour TFT screen 480 x
Network Camera. Quick Operation Guide V4.0.1
Network Camera Quick Operation Guide V4.0.1 Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to DS-2CD8253F-EI(Z),
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
How To Use A Siedle Phone With A Sim Sims 2 (Analogue) And Sims 1 (Analog) For A Long Distance Phone (Ancient) For Free (Analphone) For Two Weeks (For A Long
Performance features Siedle Scope General 1 Scope base station 2 Scope handset 3-5 Siedle app for Smart Gateway Mini 6-7 DECT repeater 8 Key 9 Performance features in general Finish Mobile video indoor
Multi-Profile CMOS Infrared Network Camera
Multi-Profile CMOS Infrared Network Camera Quick Start Guide About multi-profile Multi-profile stands for simultaneously video stream. The Network Camera and Video Server can generate MPEG4 and MJPEG streaming
D45. SySTEm. ThE high-performance
D45 ThE high-performance SySTEm Security monitoring system with digital BUS technologies High efficiency system and quick installation for both backbone and riserdevicesthankstotheuse of cat.5e UTP cables
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
Network Camera SNC-P1
Network Camera SNC-P1 FEATURES All-in-One Network Camera Enter the World of IP Monitoring with the Sony SNC-P1 MPEG-4/JPEG Network Camera Sony introduces its new SNC-P1 MPEG-4/JPEG network color camera,
SNC-VL10P Video Network Camera
SNC-VL10P Video Network Camera CHANGING THE WAY BUSINESS 2AM. WATCHING HIS NEW PRODUCTION LINE. 10,000 MILES AWAY. COMMUNICATES www.sonybiz.net/netstation CORPORATE COMMUNICATIONS SURVEILLANCE VIDEOCONFERENCING
VTO6xxx. IP door stations. User manual
VTO6xxx IP door stations User manual Table of Contents 1 Product Appearance 2 Basic Function Introduction 2.1 Call Manager Center 2.2 Call User 2.2.1 Connecting Status 2.2.2 Calling Status 2.3 Monitor
Baudisch.DoorController
VoIP and SIP for analog door stations. Implementation of the analog signals of existing intercoms on Ethernet Connection of several call buttons Switching output for door opener and light Use of existing
Datasheet. Unified Video Surveillance Management. Camera Models: UVC, UVC-Dome, UVC-Pro NVR Model: UVC-NVR. Scalable Day or Night Surveillance
Unified Video Surveillance Management Camera Models: UVC, UVC-Dome, UVC-Pro NVR Model: UVC-NVR Scalable Day or Night Surveillance Advanced Hardware with Full HD Video Powerful Features and Analytic Capabilities
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
Link SIP Door Phone. Manual V1.0. Linkcom France. 1 11 rue du Soleil Levant 92140 CLAMART Copyright 2008 Linkcom Tous droit réservés
Link SIP Door Phone Manual V1.0 1 Table of Contents 1. BASIC DESCRIPTION...3 1.1. FEATURES... 3 1.2. MODULE ASSEMBLY... 3 2. MODULE FEATURES...4 2.1. BASIC MODULE... 4 2.2. RELAYS CONNECTION... 4 2.3.
Local supplier shall be ISO 9001 & OHSAS 18001 Certified Company.
VIDEO INTERCOM SYSTEM Introduction: The contractor shall supply, install, test and commission a modern Electronic Digital Open Voice Color Video Entry Phone System of an approved manufacturer and design
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Honeywell Security. Honeywell Hello Series Video Door Phone System Product Catalog. Smile reaches your heart. Smile reaches your heart
Honeywell Security Smile reaches your heart Honeywell Hello Series Door Phone System Product Catalog Smile reaches your heart Honeywell Security, Your Partner of Choice! Commitment Constant Innovation
USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family
USER MANUAL EN KIT VIDEO DOOR PHONE smart 1 family Harry Johnston Call from the outdoor panel keys; Possibility to see on the terminal's display the person calling ; Duplex hands-free audio communication;
accessories and TechnoloGy Behnke electronics sip view inside a Behnke sip intercom Technology
accessories and TechnoloGy Behnke electronics sip view inside a Behnke sip intercom 5 6 2 3 8 5 4 7 1 9 1 Module housing Fixing the modules in the front frame and holder for electronics housing 3 4 2 configuration
XIGHTOR DOOR ENTRY SYSTEM. Company Name company address line 1 company address line 2 www.schneider-electric.com
DOOR ENTRY SYSTEM SE002-0115-00 Schneider Electric - All rights reserved Company Name company address line 1 company address line 2 www.schneider-electric.com As standards, specifications and designs change
High performance surveillance. 24/7.
Network Mini Fixed Dome Cameras High performance surveillance. 24/7. High performance surveillance, indoor or out. Day-time, night-time or round the clock. Sony introduces two new additions to its line-up
DOOR COMMUNICATION 2.0
DOOR COMMUNICATION 2.0 TCS over IP www.tcsag.de THE TCS IP-GATEWAY BASIC FOR THE SINGLE-FAMILY HOME Cost-effective integration of systems into the IP network Installed in the control cabinet, the new IP-Gateway
Innovative DOOR STATION Solutions
Innovative DOOR STATION Solutions When a visitor arrives at your front door or gate we ring... Your mobile when you are out Your normal telephones in your home Your PABX system in your office Communicating
SFERA. NEw. 2 wire. audio ViDEO PUSHBUTTON PANELS
SFERA NEw 2 wire audio ViDEO PUSHBUTTON PANELS new SFERA TWO personalities FOR ONE SINGLE electronic HEART The QR Code provides direct access to multimedia contents. The service is very easy to use, and
4UHD. SDX-8x8. Flexible and comprehensive professional Digital Modular Matrix (DMM) for Commercial, Education and Residential
SDX-8x8 Flexible and comprehensive professional Digital Modular Matrix (DMM) for Commercial, Education and Residential K 4UHD The Smart-e SDX-8x8 features The SDX-8x8 is a professional flexible Digital
Door Phone VoIP. User manual IPDPS 01C IPDPS 02C IPDPS 01 IPDPS 02
ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic www.alphatechtechnologies.cz Door Phone VoIP IPDPS 01C IPDPS 02C IPDPS 01 IPDPS 02 User manual Welcome We congratulate you on purchase
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
Monitors. Platea Monitor
Monitors Platea Monitor The common features of Platea monitors are: Casing manufactured in ABS RAL9003 white colour. 4" b/w flat tube screen or color TFT LCD of 'A Grade' quality. Brightness and contrast
IDDERO TOUCH PANELS. Video door phone configuration. www.iddero.com 120719-02
IDDERO TOUCH PANELS Video door phone configuration www.iddero.com 120719-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 INSTALLATION... 3 3 INITIAL CONFIGURATION... 4 4 2N HELIOS IP VIDEO DOOR PHONES... 5
345020-345021. TiIrydeTouchPhone. User guide 10/11-01 PC
345020-345021 TiIrydeTouchPhone User guide 10/11-01 PC 2 TiIrydeTouchPhone User guide Contents 1. Hardware and Software requirements 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements
Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting
Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration
TELEPHONE ACCESS CONTROL ENTRY STATIONS
caph caph DIGITAL AND ANALOG INTERCOM TELEPHONE ACCESS CONTROL ENTRY STATIONS CASTEL s telephone intercom systems make it easy to set up communication between a street entry station and a telephone station.
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Software and Display instruments
Software and Display instruments 272 Overview Software and Display instruments 276 VEGA Inventory System 278 DTM Collection und PACTware 279 VEGACONNECT 280 PLICSCOM, PLICSLED 282 VEGADIS 81, 82, 176 271
Information. Siemens Enterprise Communications www.siemens-enterprise.com
Information HiPath 500 V9 The Professional Communications System for Small Businesses and Offices HiPath 500, the classic phone system, is based on reliable ISDN technology and delivers the highest possible
Wireless Day / Night Cloud Camera TV-IP751WIC (v1.0r)
(v1.0r) TRENDnet s Wireless Day / Night Cloud Camera, model, takes the work out of viewing video over the internet. Previously to view video remotely, users needed to perform many complicated and time
Video surveillance camera Installation Guide
Video surveillance camera Installation Guide TV7085 TV7086 TV7087 TV7088 14 1. Preface Dear Customer, Thank you for purchasing this Eyseo digital surveillance camera. You made the right decision in choosing
Datasheet. Unified Video Surveillance Management. Camera Models: UVC, UVC-Dome, UVC-Micro, UVC-Pro NVR Model: UVC-NVR
Unified Video Surveillance Management Camera Models: UVC, UVC-Dome, UVC-Micro, UVC-Pro NVR Model: UVC-NVR Scalable Day or Night Surveillance Advanced Hardware with Full HD Video Powerful Features and Analytic
Setting Up the Cisco Unified IP Phone
CHAPTER 3 This chapter includes the following topics, which help you install the Cisco Unified IP Phone on an IP telephony network: Before You Begin, page 3-1 Understanding the Cisco Unified IP Phone 7962G
D/N VARI-FOCAL IR CAMERA
D/N VARI-FOCAL IR CAMERA PIH-0364X/0368X/0384X/0388X W/S INSTRUCTION MANUAL IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before the unit is operated.
1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions
Facility Pilot Server Art. No. : FAPV-SERVER-REG Facility Pilot Server Art. No. : FAPVSERVERREGGB Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically
Operating Instructions. Keypad 2605..
Operating Instructions Keypad 605.. Contents Device description...4 Device presentation...5 Areas of application...6 Operation...8 Acknowledgement signals... 10 Start-up sequence... 11 Connection terminals...1
KS732 Family. Rev. 1.01 KS732. 1/3 CCD Color USB Camera
KS732 Family 1/3 CCD Color USB Camera The KS732 is a product line of 1/3" compact cameras which is available as an USB version. It is designed to be used in a wide variety of professional industrial, security
Pancode VoIP/Pantel VoIP Access Control Door Phones. Installation and Programming Manual Release 1.0 June 2006
Pancode VoIP/Pantel VoIP Access Control Door Phones Installation and Programming Manual Release 1.0 June 2006 Table of Contents 1 Introduction... 2 1.1 Pancode VoIP/Pantel VoIP Kit Contents... 3 2 Physical
Megapixel IP66. IP66 Waterproof Housing, Cable through bracket and Anti-Fog Front Cover
BU-3026 3-Megapixel 25 meter Wide Angle IR Bullet Type IPCAM IP66 Housing with Cable through Bracket 3-Megapixel 1/2.5" CMOS Sensor Support 25FPS at 2048x1536 or 30FPS at 1080P 802.3af PoE Port 2.6mm CS
Day / Night IR Color Camera User Manual V2.1.0
Day / Night IR Color Camera User Manual V2.1.0 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-2CC102P(N)-IR1(IR3)(IR5),
Personal Assistance System Owner's Guide
Owner's Guide PSC07 READ THIS FIRST This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions,
Amcrest 960H DVR Quick Start Guide
Amcrest 960H DVR Quick Start Guide Welcome Thank you for purchasing our Amcrest 960H DVR! This quick start guide will help you become familiar with our DVR in a very short time. Before installation and
7 MEGAPIXEL 180 DEGREE IP VIDEO CAMERA
Scallop Imaging is focused on developing, marketing and manufacturing its proprietary video imaging technology. All our activities are still proudly accomplished in Boston. We do product development, marketing
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
video door entry system offer
video door entry system offer CATALOGUE 2013 BTICINO Specialists in Video Door Entry Systems BTicino, introduces a complete range of products and systems capable of meeting all application and building
IDDERO TOUCH PANELS. Video door phone configuration. www.iddero.com 120130-02
IDDERO TOUCH PANELS Video door phone configuration www.iddero.com 120130-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 INSTALLATION... 3 3 INITIAL CONFIGURATION... 4 4 2N HELIOS IP VIDEO DOOR PHONES... 5
Software for network-based video recording system SISTORE MX NVR (Ver. 2.57)
Software for network-based video recording system SISTORE MX NVR (Ver. 2.57) SISTORE MX 4 NVR SISTORE MX 9 NVR SISTORE MX 16 NVR Software package for network-based video monitoring and recording of up
MultiViu Flex 7 Data Sheet
Division Interior MultiViu Flex 7 Data Sheet Picture: MultiViu Flex 7 Picture: MultiViu Flex 7 Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939,
A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
ENDURA - WS5050 PC WORKSTATION TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1 28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2 28 23 00 VIDEO SURVEILLANCE LEVEL 3 28
2 WIRE video door entry system
J J N P CLASSE 00 VE WIRE video door entry system 5 Description Front view WIRE handsfree colour video handset with inductive loop, preset for different types of installations, depending on the accessories
Broadway 3D Security System
Broadway 3D Security System USER MANUAL v.1.1.0 Artec Group, Inc. 2012 Table of contents 1. General Information... 3 2. Delivery Package... 4 3.1. B3D BR... 5 3.2. B3D B... 6 3.3. B3D BM... 7 4. Integration
High definition day/night
PROFESSIONAL High definition day/night security CAMERA HIGH DEFINITION 600 TVL colour CAMERA DELIVERING HIGH QUALITY VIDEO with accurate colour rendition POWERFUL NIGHT VISION 24 INFRA-RED LEDs FOR NIGHT
EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE
EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE You can program online 24/7 giving you the freedom to work when and where you want. From remote bookkeeping and access, to security control on the ground
ES-CAM2AU IP Camera. www.etiger.com
ES-CAM2AU IP Camera www.etiger.com EN Box content Connect your smartphone to the camera - ES-CAM2AU x1 - Mounting bracket x1 - AC Adaptor x1 - User Manual x1 and apps Before using the ES-CAM2AU, download
F453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
WATCH OVER YOUR WORLD FROM ANYWHERE IN THE WORLD
WATCH OVER YOUR WORLD FROM ANYWHERE IN THE WORLD THE VERSATILE SOLUTION TO PROTECT YOUR HOME OR BUSINESS INSTANT REMOTE CONNECTIVITY DAY & NIGHT, INDOOR/OUTDOOR REAL-TIME RECORDING UP TO 9 MONTHS EXPANDABLE
Information. Communication for the open minded. Siemens Enterprise Communications www.siemens-enterprise.com/open
Information HiPath 500 V8 The Professional Communications System for Small Businesses and Offices HiPath 500, the classic phone system, is based on reliable ISDN technology and delivers the highest levels
UPnP POE. POE-FSH804 PoE Status Link/ACT SPEED 1. POWER PoE Max. 8-Port Fast Ethernet POE Switch. POE Switch
POE-FSH804 8 7 6 5 PoE Status Link/ACT SPEED 4 3 2 1 POWER PoE Max. 8-Port Fast Ethernet POE Switch 1/3 CMOS Dual Stream PoE IP Camera T he is a high-performance camera designed for professional indoor
Audio and Video Door Entry System LIELBA - AD14
Technical Teaching Equipment Audio and Video Door Entry System LIELBA - AD14 Products Products range Units 4.-Electricity ELEMENTS ALLOCATION ALI02 POR06 POR05 and POR07 POR04 POR08 Modules: ALI02= Main
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
Structured Cabling, Earthing & Equipotential Bonding
White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01 1 Abstract All Dallmeier network products (PoE cameras, recorders,
IP Camera (L series) User manual 2013-05 V1.1
Dear users, the configuration for this camera is professional, so please read the user manual carefully before using the camera. IP Camera (L series) User manual 2013-05 V1.1 Statement If the user manual
Wireless PTZ Cloud Camera TV-IP851WC (v1.0r)
(v1.0r) TRENDnet s Wireless PTZ Cloud Camera, model, takes the work out of viewing video over the internet. Previously to view video remotely, users needed to perform many complicated and time consuming
IDDERO HCx-KNX TOUCH PANELS. Quick start guide. www.iddero.com 130125-02
IDDERO HCx-KNX TOUCH PANELS Quick start guide www.iddero.com 130125-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 IDDERO CONFIGURATION SOFTWARE... 3 2.1 Installation and First Steps...3 3 TOUCH PANEL CONFIGURATION...
ONBACK. We Offer Full Systems, Monitors, Cameras and Accessories. Call Us Toll Free: 1-800-535-0104 Fax: 740-366-0771 Website: www.holtzindustries.
Thinking About Safety... Think RayView! A Division Of: Holtz Industries, Inc. We Offer Full Systems, Monitors, Cameras and Accessories We Accept These Major Credit Cards ONBACK Call For Safety s Sake Your
Technical Specifications
ZCAM3 HAZARDOUS AREA THERMAL IMAGING CAMERAS DS-003 Issue 01 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products
Basler. Line Scan Cameras
Basler Line Scan Cameras High-quality line scan technology meets a cost-effective GigE interface Real color support in a compact housing size Shading correction compensates for difficult lighting conditions
FB-500A User s Manual
Megapixel Day & Night Fixed Box Network Camera FB-500A User s Manual Quality Service Group Product name: Network Camera (FB-500A Series) Release Date: 2011/7 Manual Revision: V1.0 Web site: Email: www.brickcom.com
4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature
4-Port 10/Mbps with + 1-Port FX Industrial Ethernet Switch Wide Temperature 15 F Fiber Optic Link Capability for Flexible Distance Extension The series equips one Base-FX port that provides more flexibility
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Network Projector Operation Guide
Network Projector Operation Guide Table of contents Preparation...3 Connecting the projector with your computer...3 Wired connection... 3 Wireless connection (for selective models)... 4 QPresenter...7
3 Specification. Master Chip Broadcom 1190. Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice
I20-T Door Phone 1 Description I20-T Voice Access control is a digital IP door phone with Fanvil Voip Solutions (Broadcom chip 1190), stable and reliable. FDSP ensure voice loud and clear. Good looking,
VIDEO DOOR PHONE SYSTEM
ENGLISH VIDEO DOOR PHONE SYSTEM USER MANUAL Manual covers IH-692 Master and IH-692 Slave Monitors PRECAUTIONS BEFORE INSTALLATION Connect this unit ONLY to other compatible units. Do not connect it to
SECURITY CAMERA SYSTEM
SECURITY CAMERA SYSTEM WATCH OVER YOUR WORLD FROM ANYWHERE IN THE WORLD PROFESSIONAL-GRADE VIDEO SURVEILLANCE A high quality system connecting you to your entire property, expandable up to 16 cameras.
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
Speed Dome. Technical Manual
Speed Dome Technical Manual 1 Notices The information in this documentation is subject to change without notice and does not represent any commitment on behalf of HIKVISION. HIKVISION disclaims any liability
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
ES-CAM3A Outdoor IP Camera
ES-CAM3A Outdoor IP Camera www.etiger.com EN Specifications - Image sensor: 1/3 CMOS, 3.15 MP - Video resolution: 160x90, 320x180, 640x360, 1280x720 (H.264) - Digital zoom: 2x - Focal: 3.6mm, Aperture:
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
QuickSpecs. HP IP Console Switch with Virtual Media Overview
Overview HP's IP Console Switch with Virtual Media is a key component in managing the heterogeneous data center and along with the IP Viewer software allows remote access to multiple servers running various
Product Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for