RESOL DeltaSol A. Mounting Connection Operation Examples. Manual
|
|
|
- Bruno McBride
- 10 years ago
- Views:
Transcription
1 RESOL DeltaSol A Mounting Connection Operation Examples A Manual Thanks for buying a RESOL controller. Read this manual carefully to get the best performance from this unit.
2 Contents Imprint... 2 Security devices... 2 Technical data and function survey Installation Mounting Electrical connection Adjustments and commissioning Anti-freeze function Blinking codes Tips for fault diagstics Application examples... 6 Annex: Fault diagstics...8 Safety regulations: Please read the following information carefully before installing and operating the controller. In this way damage to the solar system by wrong installation will be avoided. Please observe that the mounting is adapted to the characteristics of the building, that the local regulations are respected and is conform to the technical rules. DIN 4757, part 1 Solar heating systems with water and water mixtures as heat transfer medium; Demands to the safety realization. DIN 4757, part 2 Solar heating systems with organic heat transfer medium; Demands to safety realization. DIN 4757, part 3 Solar heating systems; solar collectors; Meanings; safety regulations; Testing of standstil temperature DIN 4757, part 4 Solar thermal systems; solar collectors; determination of efficiency, heat capacity and pressure loss. In addition to that European standards are worked out: PrEN Thermal solar systems and their components;collectors, part 1: General demands. PrEN Thermal solar systems and their components; collectors; part 2: Test processes PrEN Thermal solar systems and their components; prefabricated systems, part 1: General demands. PrEN Thermal solar systems and their components; prefabricated systems, part 2: Test processes PrEN Thermal solar systems and their components; Customer-designed manufactured systems, part 1: General demands. PrEN Thermal solar systems and their components; Customer-designed manufactured systems, part 2: Test processes PrEN Thermal solar systems and their components; Customer-designed manufactured systems, part 3: Performance test of warm water stores. This mounting- and operation manual including all parts is copyrighted. Ather use outside the copyright requires the approval of RESOL - Elektronische Regelungen GmbH. This especially applies for copies, translations, micro films and the storage into electronic systems. Editor: RESOL - Elektronische Regelungen GmbH Important tice: We took a lot of care over the texts and drawings of this manual and to the best of our kwledge and consent. As faults can never be excluded, please te: Your own calculations and plans under consideration of the current rms and DIN-directions should only be basis for your projects. We don t offer a guarantee for the completeness of the drawings and texts of this manual - they only represent some examples. They can only be used on own risk. No liability is assumed for incorrect, incomplete or false information and the resulting damages. Errors and technical changes excepted. 2 Scope of delivery: controller DeltaSol A (full kit incl. 2 temperature sensors) spare fuse under cover ccessory bag consisting of silicone sealing, fastening screws and dowels, strain relief clamp and srews manual
3 Technical data Housing: plug-in plastic PC-ABS Protection type: IP 20 / DIN Ambient temp.: C Size: Ø130 mm, 45 mm height Mounting: wall mounting Display: 1 function control lamp Inputs: 2 sensor inputs PT1000 Outputs: 1 standard relay (changeover contact) Switch-on difference: T K adjustable Switch-off difference: 1,6 K below switch-on difference Control range: C Power consumption: max. 4 A Powersupply: V~ DeltaSol A Due to the tough and consciously simple designed concept for the controller DeltaSol A,this low-priced differential controller can be universally used in solar-, heating- and air conditioning systems. The huge control range and the adjustable temperature difference make an application in nearly all systems possible in which switching processes are realised by temperature differences. The housing is optionally available with a sealing, which protects the electronics against dripping water (IP22). The controller checks a temperature diffference T measured by one of two temperature sensors by comparing this difference with a preadjusted temperature difference (adjustable within the range of K). The control of the system is effected by a standard relay (= changeover contact), to which several motors or electrical valves can be connected. The controller switches- ON, if the adjusted temperature difference is exceeded; if this difference is underrun by 1,6 K, the controller switches-off. Order indications RESOL DeltaSol A RESOL DeltaSol A - full kit incl. 2 temperature sensors Pt1000 (1 x FKP6, 1 x FRP6) Accessory Overvoltage protection It is highly recommended to connect the RESOL overvoltage protection SP1 to all collector sensors in order to avoid overvoltages (e.g. by lightning). RESOL SP Electrostatical discharges can lead to damages of electronic components! Dangerous voltage on contact! 3
4 1. Installation Warning! 1.1 Mounting Switch-off power supply before opening the housing. housing 2 cover 3 base The unit must only be located internally. It is t suitable for installation in hazardous locations and should t be sited near to any electromagnetic field. Please pay attention to a separate laying of the cable lines and installation of ac power supply. 1. Choose a mounting place, drill two holes of Ø 6 mm side by side with a distance of 113 mm and fit in the enclosed dowels. 2. Fix the controller by means of the enclosed screws (4 x 40 mm)(pos. 1). 3. The electrical connection must be effected w. Power supply of the controller ( V ) must be effected by external power switch Electrical connection fuse T4A Connection of the sensors at the clamps: 1 / 2 = sensor 1 (e. g. collector sensor) 3 / 4 = sensor 2 (e. g. store sensor) Connection of the consumer to the clamps: 7 = rmally open contact relay (RO) 8 = break contact relay (RC) 9 = neutral contact relay (N) ground clamp collective terminal strip ac power supply to the clamps: 10 = neutral conductor N 11 = conductor L ground clamp (collective terminal strip) sensor 1 sensor 2 ground clamp (collective terminal strip) ac power supply relay (consumer) Insert sealing band without strain into the nut The guides of the required insertion channels must be broken away at the bottom side of the cover. The lines are to be fixed to the housing by enclosed strain relief supports and screws (pos.2). If necessary, activate anti-freeze function by jumper. Instert enclosed silicone sealing in base nut (without strain), if dripping water protection is necessary. Put on the cover and screw it (pos. 3). If necessary, adjust temperature difference T. Put on housing cover and screw it (pos. 4). 4
5 2. Adjustments and commissioning operating control lamp potentiometer for temperature difference 3. Anti-freeze function The controller comes with a deactivated anti-freeze function (by RESOL.) 4. Blinking codes Before closing the housing, the specific temperature difference T must be adjusted at the potentiometer within a scale of 2 K K. In practice, values between 6K...8K have proved. The controller comes with a switch-off delay (hysteresis) adjusted by RESOL to 1,6 K and cant be changed. The controller switches over the relay if the temperature difference between the sensors S1 and S2 is reached or exceeded. The controller switches the relay back, if the adjusted temperature difference is again underrun by 1,6 K. The controller RESOL DeltaSol A is equipped with antifreeze function. Solar systems are rmally run with a glycolwater mixture. Due to the chemichal features of this mixture an aditional anti-freeze protection is t necessary. But in some cases, solar systems are only operated with water. The anti-freeze function responds to the temperature of sensor S1 (collector sensor). As soon as this sensor measures a temperature below +4 C, warmer water from the store is pumped into the collector in order to avoid damages at the collector. If a temperature of +5 C is reached at S1, the pump switches-off. Please te that due to the limited heat reserve of the store, this function is only appropriated for those regions in which temperatures around freezing point are only reached few days per year. The jumper must be set to the position marked correspondingly in order to activate (on) or deactivate (off) the anti-freeze function. Relay active Anti-freeze protection active green green (blinking) The LED shows the actual operating status of the controller. 5. Tips for fault diagstics If the controller does t work perfectly, please check the following items: bracket for spare fuse (interior part of cover) C If the controller does t switch-on correctly, even if ac power supply is impressed, please check the fuses (see 1.2). The controller is guarded by a fine fuse T4A, which can be replaced after having removed the housing and the cover. A spare fuse is enclosed on the backside of the cover. Please check the sensors. Sensors which are t connected, must have the following resistance values depending on the given temperature. Ω C Ω C Ω Resistance values of Pt1000-sensors 5
6 6. Application examples Standard solar system with 1 store S1 S2 RO RC N N L S1 RO S2 Use ground clamp collective terminal strip! If the current temperature difference T between collector sensor S1 and store sensor S2 exceeds the temperature difference adjusted at the controller, the solar pump is switched-on. Heat is transported from the collector to the store; in doing so, the temperature difference is reduced. If the adjusted temperature difference is underrun by a difference of 1,6 K (hysteresis, cant be changed), the pump is switched-off again. S1 = collector sensor S2 = store sensor RO = solar pump Heating circuit reverse raising S1 S2 RO RC N N L S1 S2 R0 Use ground clamp collective terminal strip! If the temperature difference T between store sensor S1 and heating circuit reverse sensor S2 exceeds the temperature difference adjusted at the controller, the 3- way-valve is switched-over. The reverse temperature of the heating circuit is raised by the heat of the store so that less conventional enery is necessary for reaching the feed flow temperature; in doing so, the temperature difference 6 is reduced. If the adjusted temperature difference is underrun by a difference of 1,6 K (hysteresis, cant be changed), the valve is switched to initial position. S1 = store sensor S2 = heating circuit reverse sensor RO = 3-way-valve
7 Heat exchange (between two stores) S1 S2 RO RC N N L S1 R0 S2 Use ground clamp collective terminal strip! If the temperature difference T between store (1) sensor S1 and store (2) sensor S2 exceeds the temperature adjusted at the controller, the circulation pump is switched-on. Heat is transported from the store (1) into store (2); in doing so, the temperature difference is reduced. If the adjusted temperature difference is underrun by a difference of 1,6 K (hysteresis, cant be changed), the pump is switched-off again. S1 = store (1) sensor S2 = store (2) sensor RO = circulation pump 7
8 Annex: Fault diagstics Pump is overheated, but heat transfer from collector to the store, feed flow and return flow are equally warm, perhaps also bubble in the lines. Pump starts for a short moment, switches-off, switches-on again, etc. ( controller hunting ) Air in the system? Is the collector circuit plugged at the dirt trap? Exhaust the system; increase system pressure to at least static primary pressure plus 0,5 bar; if necessary continue to increase, switch the pump for a short time off and on. Is the temperature difference at the controller too small? Wrong placing of the collector sensor? Change Ton and Toff accordingly. o.k. Clean the dirt trap Plausibility control of the option tube collector special function? Mount the collector sensor at solar feed flow (warmest collector output); use the immersion sleeve of the respective collector. Pump starts up very late and soon stops working soon. The temperature difference between store and collector increases ermously during operation; the collector circuit cant dissipate the heat. Switch-on-temperature difference Ton too large? Collector circuit pump defect? Change Ton and Toff accordingly. Control / replacement Collector sensor unfavourable placed (e.g. contact sensor instead of immersion sleeve sensor? Heat exchanger calcified? Decalification If necessary activate tube collector function. o.k. Heat exchanger plugged? Cleaning Heat exchanger too small? New calculation of the dimension. 8
9 Stores are cooled during the night. The solar circuit pump does t work although the collector is obviously warmer than the store. Does collector circuit pump run during the night? Check the controller functions Does the control LED flash? There is current; check fuses / replace them and check power supply. Collector temperature is at night higher than ambient temperature. Check the return flow preventer in feed flow and return flow with regard to the functional efficiency. Does the pump start up in manual operation? The adjusted temperature difference for starting the pump is too high; choose a value which makes more sense. Is store insulation sufficient? Intensify the insulation. Is the current of the pump released by the controller? Is the pump stuck? Is store insulation close eugh to the store? Replace or intensify the insulation. Put the pump into operation by means of a screwdriver; is it passable w? Are the store connections insulated? Insulate connections. Are the fuses of the controller o.k.? Is the pump defective - replace it. Warm water outflow upwards? Change connection and let the water flow sidewards or through a siphon (bow downwards); less store losses w? Replace the fuses. Controller seems to be defective - replace it. o.k. Control the return flow preventer in warm water circulation- o.k. Please also check further pumps which are connected to the solar store. Cleaning or replacement. 9
RESOL DELTA Sol. universal temperature differential. regulator for solar- and heating systems Mounting instructions. page 1/11
page 1/11 universal temperature differential regulator for applicati in solar- and heating systems plastic housing with easy mounting and compact dimensis digital display temperature user-friendly handling
1 General information
1 General information 1.1 About this manual This manual describes the installation, function and operation of an integrated solar control system, which is suitable for split pressurized solar heating system.
eltasol RESOL DeltaSol M Manual Installation Operation Commissioning Fault localisation for the professional
RESOL DeltaSol M Manual for the professional Installation Operation Commissioning Fault localisation Thanks for buying a RESOL. Read this manual carefully to get the best perfomance from this unit. DeltaS
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Installation and operating instructions. Solar charge controller Solarix MPPT 2010 730927 Z03 1242 730927 Z03 1242
Installation and operating instructions Solar charge controller Solarix MPPT 2010 EN 730927 Z03 1242 730927 Z03 1242 1 Contents 1. About these instructions...3 1.1 Applicability...3 1.2 Users...3 1.3.
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification
DeltaSol C Plus. RESOL DeltaSol C Plus *48003311* B Manual. Mounting Connection Operation Troubleshooting Examples
RESOL DeltaSol C Plus *48003311* 48003311 Mounting Connection Operation Troubleshooting Examples Thank you for buying this RESOL product. Please read this manual carefully, to get the best performance
Zenith Solar thermal 4.5m pump station Installation manual
Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
DeltaSol E. RESOL DeltaSol E. Mounting Connection Handling Fault localization. manual
RESOL DeltaSol E Mounting Connection Handling Fault localization DeltaSol E B manual Thank you for buying this RESOL product. Read this manual carefully to get the best perfomance from this unit. www.resol.de
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.
Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
Operating Instructions. Room temperature controller
Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!
EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage
Regulators. Heat pumps. Qualified technician NIBE TM AP-CS2.0. Operating Instructions UK
Operating Instructions UK Heat pumps Regulators Qualified technician NIBE TM AP-CS2.0 We reserve the right to make technical changes. 83052306bUK Translation of the operating manual Please read first This
DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches
DS 1.102 02/99 AIR ROOM TEMPERATURE SENSOR with fan speed control switches Specification No. 528-X-XXX* The Active Room Temperature sensor incorporating fan speed control switches is designed to give a
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
COMPACT eco For firmware version 1.8 Rev0
User manual Control Unit for an Electric Height-Adjustable Desk COMPACT eco For firmware version 1.8 Rev0 Subject to change without notice. Errors and omissions excepted. LOGICDATA cannot accept responsibility
WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA
Thank you for purchasing the Maximum wind speed alarm. The Maximum wind speed alarm is a dual set point wind speed indicator with a two digit LED display. It contains a yellow light to display one set
its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Dehumidifier D 850E. - Instruction manual version 02
Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
KNX R. Rain Sensor. Installation and Adjustment
EN KNX R Rain Sensor Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Installation notes... 4 2.2. Location... 4
GAE953 Electrical Alarm Unit 19" with Indicator
Master Instruction 08.95 MI EIO2211 A-(en) GAE953 Electrical Alarm Unit 19" with Indicator The electrical alarm unit GAE953 gives a signal when one or two set alarm values have been exceeded. Input signals
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual
V - JET Counteflow System V-JET Counterflow System Installation and Operation Manual 1. System Installation By purchasing the V - JET counterflow system you have obtained high-quality product, which will
GL-235 Solar Pool Controller
GL-235 Solar Pool Controller Installation & Operation Manual G LDLINE CON TROLS www.goldlinecontrols.com Description The GL-235 is a differential temperature control for solar heating of pools, spas, and
Wind Sensor W-RS485 with RS485 Interface
Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Doc. No: 412-121033 Issue: 1 Date: Aug 2014. BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02
Date: Aug 2014 THERMAL TRANSFER CARD PRINTER BTT-02 TABLE OF CONTENTS Introduction... 3 System Contents and Initial Checks... 3 Installation... 4 Preparation of Installation Site... 4 Printer Connections...
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS
INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the
For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.
s For UK only RX39.1 and the applications package SP-03 are sold in the United Kingdom only. 3 876 3876P01 RX Room controller Communicating controllers for fan-coil applications SP-03 RX39.1 The RX39.1
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
ELECTRICAL PLUG TYPE CONNECTIONS
ELECTRICAL PLUG TYPE CONNECTIONS THE COMPLETE RANGE FOR COMMERCIAL VEHICLES, PASSENGER CARS AND SPECIAL VEHICLES DETAILED PRODUCT OVERVIEWS WITH ACCESSORIES AND WIRING DIAGRAMS ESPECIALLY STURDY PLUG SYSTEMS
Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.
Data logger Installation and operating instructions SOREL Connect Read carefully before installation, commissioning and operation 1.1. - Specifications Description of data logger Electrical specifications:
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
OEM Relative and differential pressure switch type 605
OEM Relative and differential pressure switch type 605 Pressure range 20... 400 Pa Type 605 pressure switches are specially developed for use in gas fired heating systems. There are more than 10 million
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Technical Support Information No. 113 Revision 2.0 March 2005
Process Instrumentation and Analytics - A&D PI 2 - Karlsruhe Page 1 of 16 Neues PECM ersetzt alle PECM s in Maxum und Maxum Edition II - New PECM replaces all PECMs in Maxum and Maxum Edition II General
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
Install Guide 3M-50. Caution. Caution
PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system.
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
Install Guide CT101. Caution. Caution
Install Guide CT101 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
TRADE PRODUCTS 2014. Electronic systems for recreational vehicles Supplying controlling indicating
TRADE PRODUCTS 2014 Electronic systems for recreational vehicles Supplying controlling indicating All systems under control Monitoring and controlling systems by Schaudt leading in safety and comfort in
Please read operating instructions carefully before use and keep for further reference.
GB OPERATING INSTRUCTIONS LEISTER Welding-Pen R Hot air tool Please read operating instructions carefully before use and keep for further reference. APPLICATION The LEISTER Welding-Pen R is a hot air tool
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
SMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
www.somfy.com Telis 4 Soliris RTS Operating and installation guide Ref.5054466A
www.somfy.com Telis 4 Soliris RTS Operating and installation guide Ref.5054466A Contents 1. Brief introduction to the Telis 4 Soliris RTS remote control 3 1.1 What is the Telis 4 Soliris RTS for? 3 1.2
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
HOSCH. Sprung blade scraper with heating system. Documentation Type B6C/H
HOSCH Sprung blade scraper with heating system Documentation Type B6C/H 1 HOSCH Sprung blade scraper Type B6-C/H with heating system Table of contents 1 Intended use Page 3 1.1 Use 1.2 General operating
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,