1 General information
|
|
|
- Caitlin Armstrong
- 10 years ago
- Views:
Transcription
1 1 General information 1.1 About this manual This manual describes the installation, function and operation of an integrated solar control system, which is suitable for split pressurized solar heating system. Before installing and operating the device, please read the following information carefully. 1.2 Safety regulations Installation, commissioning and maintenance of the device may only be performed by professional personal. All operations that require opening the device are only to be conducted cleared from the power supply. All safety regulations for working on the power supply are valid. The device must not be installed in rooms where easily inflammable material (e.g. gas or oil) mixtures are present or may occur. Before connecting the system, make sure that the energy supply matches the specifications of the device. Protect the solar control system against overloading and short-circuiting. All devices connected to the solar control system must conform to the technical specifications of the device. As soon as it becomes evident that safe operation is no longer possible, please immediately take the device out of operation. Without lightning rod, please don t use this device during a thunderstorm. 1.3 Liability waiver Improper installation or operation can cause damages to material and persons. The manufacturer cannot monitor the compliance with these instructions or the circumstances and methods used for installation, operation, utilization and maintenance of this controller. Damage by mishandling or improper installation on costumer site is immediately leading to warranty exclusion. As faults can never be excluded, we don t offer a guarantee for the completeness of the drawings and texts of this manual, they only represent some examples. They can only be used on own risk. No liability is assumed for incorrect, incomplete or false information and the resulting damages. The manufacturer preserves the right to put changes to product, technical date or installation and operation instructions without prior notice. 1.4 Symbols used Danger: Failure to observe these instructions can lead to injury of persons or safety risks. Attention: Failure to observe these instructions can result in damage to the product or environment. Note: Useful information and instructions. Operation steps: Indication of operation steps. 1
2 2 Product information 2.1 System description The solar collector pump (P1) is activated as soon as the temperature difference between the collector array (T1) and the storage tank (T2) is reached. If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference, or the storage tank (T3) reaches the maximum storage temperature, the solar pump (P1) will be switched off. T3 is used to measure the temperature of the top part of storage tank. If the turning-on condition for auxiliary heating is filled, the auxiliary heating will be activated. 1 collector array storage tank T1: Temperature sensor for collector array T2: Temperature sensor in bottom part of storage tank T3: Temperature sensor in top part of storage tank P1: Solar collector pump P2: Solar circulation pump Danger: If there is only one temperature sensor in water storage tank (usually in bottom part T2), it is possible, that the auxiliary heating function will not be activated or deactivated at a right time, because the water temperature in top part of the tank (T3) cannot be measured. In this case, if you still want to use auxiliary heating function, control program will automatically take the signal from bottom temperature sensor (T2) instead of (T3). However, water in top part of tank might often be overheated. It may cause damages to material and persons. So it is highly recommended not to use auxiliary heating in such a case. Note: To lock this function, please press System Setting button until the signal screen (see details in 3.6 Forbid/Permit using auxiliary heating). appears on the 2
3 2.2 Single-pipeline solar control system: Components 1 Operating screen 2 Pump speed regulation 3 Security valve 4 Manometer 5 Filling and flushing connector 6 WILO pump 7 Expansion vessel connector 8 Output connector 9 Input connector Installation description 3
4 should be installed in return flow of the solar circuit, as indicated above. Please see detailed installation instruction in attached manual Technical data Rated voltage AC 220V (optional: AC110V) Externality size 550mm*350mm*240mm Weight 11 kg/carton Max. own consumption 3W Range of temperature measuring NTC: 0~199 ; PT1000: 0~199 Accuracy of temperature measuring ±1 Power of pumps (solar collector pump P1 <600W and circulation pump P2) Power of auxiliary heating 3000W(optional: 6000W) System working pressure 8 bar Safety valve response pressure 6 bar Ambient temperature -20~60 Input signals T1~T3 (solar collector;top part of water tank; bottom part of water tank) Output signals 3 (auxiliary heating; solar collector pump; solar circulation pump) 2.3 Display symbols Weekday. 7days of week can be set (e.g. Week 1 means Monday ). Time. Setting hours and minutes. Time-controlled auxiliary heating. Setting three heating time periods. Time-controlled hot water circulation. Setting three time periods. Tank temperature. As turning-on/off temperature value for auxiliary heating. Frost protection signal. Overheating protection for storage tank. High temperature protection for solar collector. Holiday function signal. Switch on/off auxiliary heating manually. 4
5 Forbid/permit using auxiliary heating. Reset signal. Temperature display. Flow rate display. 5
6 3 Functions and operation Danger: Before connecting the power supply, make sure that the water tank, solar collector, solar control system and all temperature sensors are good connected! Note: For safety, auxiliary heating is locked at delivery state. The single displays on the screen. If you want to use this function, please see operation: 3.6 Forbid/Permit using auxiliary heating. 3.1 Setting week and time After power supply is switched on, please firstly set the week of the system. Press System Setting button until the signal displays on the screen. Press + - button to set weekday. (range: 0-6, e.g. 1 means Monday ) Press Confirm button to save the setting; press Cancel button to cancel the setting. Press System Setting button again until displays on the screen. Press + button to set hour, press - button to set minute. Press Confirm button to save the setting; press Cancel button to cancel the setting. 3.2 Time-controlled auxiliary heating Solar control system can be combined with electric boiler or gas/oil boiler. The system is supported with a default program which can be customized to meet your individual needs. You can create a timer program with up to three time periods to heat the water to a desired value. During the three preset time periods, auxiliary heating starts working, when the water temperature in top part of storage tank (T3) is below preset turning-on temperature, and it stops working, when T3 exceeds the required temperature. Note: Default setting: the first time period: 4:00 turning-on, 5:00 turning-off; the second time section: 10:00 ~10:00; the third time section: 17:00 turning-on, 22:00 turning-off. Press System Setting button until the signal appears. Press + - button to set the start time of the first time period. Press + to adjust hours, press - button to adjust minutes. Press Confirm button to save the settings, press Cancel button to cancel the settings. 6
7 Immediately after setting the first time period, the display enters into the operating menu of next time period. Perform like above steps, the other two time periods can be set. Note: If you want to shut off one of the three time periods, you can set a same value for both start time and end time, e.g., you can set both the start and end time of second time period at 10:00 am. 3.3 Time-controlled circulation function This function needs an extra circulation pump (P2). You can set up a timer program with up to three time periods. This pump can be triggered at times when hot water will be needed. Note: Within the preset three time periods, pump P2 always stops for 15 minutes after operating for 3 minutes. Note: Default setting: the first time period: 6:00 turning-on, 8:00 turning-off; the second time period: 10:00 ~10:00; the third time period: 19:00 turning-on, 21:00 turning-off. Three time periods should be set within one day (24 hours). Press System Setting, until displays on the screen. Press + - button to adjust the start time and end time of first time period. Press + button to adjust hours, press - button to adjust minutes. Press Confirm button to confirm the setting, press Cancel button to cancel this setting. Immediately after setting the first time period, the display enters into the operating menu of next time period. Perform like above steps, the other two time periods can be set. Note: If you want to shut off one of the three time periods, you can set a same value for both start time and end time, e.g., you can set both the start and end time of second time period at 10:00 am. 3.4 Temperature difference circulation function The solar control program works on the principle of temperature difference circulation. Solar pump P1 is triggered, as soon as the preset temperature difference between collector and tank is reached. Press System Setting button, until displays on the screen. Press + - button to adjust storage tank temperature. Default value: 60, setting range: 45~75. Press Confirm button to save the setting. Press Cancel button to cancel this function. At the same time the menu shows 10, the default value of switch-on temperature difference. Press + - button to adjust it. Setting range: 5~20. Press Confirm button to save the setting. Press Cancel button to cancel this function. Then the menu shows 5, the default value of switch-off temperature difference. Press + - button to adjust it, adjustable range: 2~12. Press Confirm button to confirm the setting. Press Cancel button to cancel the function. 7
8 Note: Between 60~70 scale can form more easily, we usually set the water tank temperature at Switching on/off auxiliary heating manually If you want to use hot water immediately, but the water temperature doesn t reach the desired value, you can switch on/off the auxiliary heating manually. Press confirm button, until displays on the screen to switch on auxiliary heating manually. Press Cancel button to switch off auxiliary heating manually. 3.6 Forbid/Permit using auxiliary heating Press System Setting button, until displays on the screen. Press Confirm button to save the setting and forbid auxiliary heating. Press System Setting button until displays on the screen. Press Cancel button to cancel the setting and permit auxiliary heating. Note: When forbid auxiliary heating, customer can t switch on/off auxiliary heating manually and time-controlled auxiliary heating function is also automatically deactivated. 3.7 Frost protection In winter, when the temperature of collector drops below the preprogrammed starting temperature of frost protection (default value 5 ), solar pump P1 starts working. When collector temperature exceeds the switch-off temperature of frost protection, pump P1 stops working and the system exits frost protection. Press System Setting, until displays on the screen. Press + - button to adjust the temperature of frost protection. Setting range: Press Confirm button to confirm the setting, press Cancel button to deactivate this function. 3.8 Storage tank overheating protection To avoid overheating of water storage tank, system is supported with an overheating protection function. When the temperature of tank (T3) is higher than the maximum tank temperature, even the condition of temperature difference circulation is reached, solar pump is still forbidden to operate. Press System Setting button, until displays on the screen. Press + - button to adjust the maximum tank temperature. Default value: 80, setting range:
9 Press Confirm button to confirm the setting, press Cancel button to quit the function. 3.9 High temperature protection of solar system When collector temperature reaches 115, and meanwhile the storage tank doesn t reach the max. tank temperature, the high temperature protection function of solar system will be activated. Press System Setting, until displays on the screen. Press + - button to adjust the maximum collector temperature. Default value: 115, adjustable range: Press Confirm button to confirm the setting, press Cancel button to quit this function Holiday function If you intend to be absent for an extended period (holiday), or hot water is not required for an extended period, you can activate the holiday function. This function is activated nightly (22:00-6:00)to re-cool the storage tank and to prevent high thermal loads of the solar system due to completely heated storage tank. Press System Setting, until displays on the screen, it indicates that the function is active. Press Confirm button to confirm this setting. Press Cancel button to deactivate this function. Note: When using holiday function, system will lock auxiliary heating automatically Anti-legionella protection To safeguard the water hygiene, solar system will monitor the storage tank temperature. If the temperature never reaches 70 in every 7 days, auxiliary heating will be activated automatically and heats the tank water to Collector emergency cut-off When the temperature of collector reaches or exceeds 120, in order to prevent evaporation of heat medium liquid and protect other components of solar system, solar circulation pump will be stopped compulsively, until the temperature of collector gets lower Memory function In case of power failure, solar control system is able to remain the preset parameters unchanged Reset Function If necessary, all the settings (except time setting) can be reset to the factory settings. 9
10 Press System Setting button, until displays on the screen. Press Confirm button, all of parameters will be reset to factory settings Manual operations Customers can monitor the flow rate anytime by viewing the signal on main operating menu. And when there are no other operations and it returns to main menu, they can also activate some functions by pressing different buttons directly. Press Confirm button 2 second to switch on/off solar collector pump (P1) manually. Press Cancel button 2 second to switch on/off solar hot water circulation pump (P2) manually. Press + - button repeatedly to check the temperature values in different part of solar system. 10
11 4 Error messages Danger: Never try to repair the solar control system yourself! Consult a specialist in case of an error. The following table explains the error messages and corresponding handling indication. Most of the problems can be found in the list below. No. Familiar problem Possible reason Solution 1 Pump works but no flow rate There is probably too much air in Replenish heat medium liquid displays. the pipeline. and exhaust the air. System has temperature difference Storage tank reaches max. tank When tank temperature drops, 2 but pump doesn t work. temperature. pump starts working. Solar collector reaches its max. When collector temperature temperature. drops, pump starts working. Auxiliary heating doesn t work. Auxiliary heating is forbidden. Activate it manually. 3 Temperature sensor has broken circuit or short circuit. Check sensor connection and make the wiring again. 4 Auxiliary heating still operates at Anti-legionella function starts up. It s normal. 23:00. 5 System pressure drops. There is air leakage in solar Check the pipeline and exhaust system. the air. Pump works but system doesn t Frost protection function is After collector temperature 6 have temperature difference, rises, pump stops working. meanwhile auxiliary heating activated, signal blinks. function starts up. The solar pumping station shows error messages in the main operating menu if there is a problem with temperature sensor. Error message meaning Possible cause Error rectification <FF > There is broken circuit Sensor wiring interrupted, not Check resistance value, with sensor connections. connected or short circuit. replace sensor if necessary. <FE > There is a short circuit Sensor wiring interrupted, not Check resistance value, with sensor connections. connected or short circuit. replace sensor if necessary. Note: A potentially defective sensor can be checked using an ohmmeter. To do this, the sensor must be disconnected. Its resistance value can be compared with the figures below, small deviation is acceptable. PT1000 resistance value Ω NTC 10K B=3950 resistance value Ω
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
1. Safety information
---- Contents 1. Safety information... 4 1.1 Installation and commissioning... 4 1.2 About this manual... 4 1.3 Liability waiver... 4 1.4 Important remark... 5 1.5 Description of symbols... 5 1.6 Description
Contents. Operation manual of solar water controller SR868C8/SR868C8Q
Contents Contents----------------------------------------------------------------------------------------------------1 1. Safety information ----------------------------------------------------------------------------------3
RESOL DeltaSol A. Mounting Connection Operation Examples. Manual
RESOL DeltaSol A Mounting Connection Operation Examples www.resol.dedeltasol A Manual Thanks for buying a RESOL controller. Read this manual carefully to get the best performance from this unit. Contents
SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE
SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE i Read the instructions Contents I. Package content... 3 II. Performance and properties... 3 III. System design...
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Split Controller. User Manual SM-SS-F 2009/01/04
Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed
Automation System TROVIS 5100 Ventilation Controller TROVIS 5177
Automation System TROVIS 5100 Ventilation Controller TROVIS 5177 ounting and Operating Instructions EB 5177 EN Electronics from SASON Firmware version 1.05 Edition September 2000 Contents 1 Scope of the
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Instruction manual. Electrobloc EBL 100-2
Instruction manual 0 Manual Electrobloc EBL 100-2 Electrobloc EBL 100-2 Type no. 911.503 Table of contents 1 Introduction..........................................2 2 Safety information.....................................2
Heating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold
Bradlee Boilers Ltd Instruction Manual for starting up Bradlee Hire Boiler from Cold To be read in conjunction with Bradlee Boiler guide to Commissioning Boilers Document Ref: HM001 1. Ensure that all
User manual. Solid (FR 98,),
User manual Solid (FR 98,), If these instructions are not followed during installation and service, Thermia Värme ABliability according to the applicable warranty is not binding. Thermia Värme AB retains
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
T5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual
QUALITY STEAM SPECIALTIES SINCE ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual Section: C500 Bulletin: C500.40 Date: 06-26-01 Supersedes: New PRODUCT DESCRIPTION: The Clark-Reliance
SMM. Installation Operation Maintenance
SMM Configuration SMM Module for Scroll Units, H Generation Installation Operation Maintenance 1 0 L80 IM 022 GB SMM Configuration SMM Module for Scroll Units, H generation Foreword These installation,
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
Operating manual For split pressurized solar hot water system controller
Operating manual For split pressurized solar hot water system controller Model SR1188 2011.03.26 Contents Contents... 1 1. Safety information... 4 1.1 Installation and commissioning... 4 1.2 About this
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
Manual of Solar Pump Station SR882 for Split Pressurized Solar Hot water System 2011.07.07
Manual of Solar Pump Station SR882 for Split Pressurized Solar Hot water System 2011.07.07 Contents Solar pump station installation and operation manual Contents... 1 Solar pump station installation and
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
Hot Water. Heat pump water heaters. Residential and Commercial R410a
Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating
ALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
User manual. 086U6297 Rev. 9 EN
User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 9 EN Thermia Värme
Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
A Class Air Source Heat Pump User Guide
A Class Air Source Heat Pump User Guide IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION 8/60476/0 Issue 1.03 Contents 1: Introduction 1 2: How the Heat Pump Works 1 2.1 Tips and advice
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
Aerona Air Source Heat Pumps
ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
How To Control A Battery Cell Phone With A Battery Power Control System
Wind/Solar Hybrid Street Light Controller User Manual Model: HY-WSC04-12AWM, HY-WSC04-12/24AWM, HY-WSC06-24AWM, HY-WSC06-48AWM 1. Product Introduction The wind/solar hybrid street light controller is an
DC-8706K Auto Dial Alarm System
DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
PART 11: START-UP PROCEDURES FOR THE INSTALLER
PART 11: START-UP PROCEDURES FOR THE INSTALLER NOTICE It is important to note that the user can adjust the heat curve down by adjusting the central heating temperature to a lower setting. 212 CENTRAL HEATING
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Remote control station WCM-FS 2.0 and solar controller WCM-SOL 1.0 home 83277602 3/2012-10
Remote control station WCM-FS 2.0 and solar controller WCM-SOL 1.0 home 83277602 3/2012-10 1 User instructions... 6 1.1 User guide... 6 1.1.1 Symbols... 6 1.1.2 Target group... 6 1.2 Guarantee and Liability...
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
User Manual. Gas fired condensing wall hung boiler. G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw)
User Manual Gas fired condensing wall hung boiler G.C.N : 41-116 - 30 (12 kw) G.C.N : 41-116 - 31 (18 kw) G.C.N : 41-116 - 32 (24 kw) CLAS HE R 12 CLAS HE R 18 CLAS HE R 24 Country of destination GB, IE
Fossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
evohome Wireless Radiator Zoning Kit Installation & User Guide
evohome Wireless Radiator Zoning Kit Installation & User Guide Getting the most from your evohome system Installation & User Guide 1 Getting the most from your evohome system Thanks for choosing an evohome
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
UM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
Air conditioning, electrical testing
just a test. Air conditioning, electrical testing 01-253 Wire and component test using VAG1598 A test box Special tools and equipment VAG 1598 A test box and VAG 1598/11 adapter cable and VAG 1598/12 VAG1526
Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +
MAKING MODERN LIVING POSSIBLE User Guide DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + www.heating.danfoss.com The English language
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Instruction Manual for Operating Panel 301 and 302
Instruction Manual for Operating Panel 301 and 30 Edition: 1/006 Edition: 1/006 Contents 1 Introduction and Overview........................ 5 1.1 Panel 301 Controls........................................
4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No
6. 6.1 and info (Menu 4) NB are shown in the event of unit faults or irregular operation Check the Current list (Menu 4) for alarm messages and refer to the list of alarms given at the end of these instructions.
Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim
Automotive sensor simulator Operating manual AutoSim Contents Introduction.. page 3 Technical specifications.... page 4 Typical application of AutoSim simulator..... page 4 Device appearance... page 5
BoilerMate SP. benchmark. user instructions A - C L A S S
A - C L A S S BoilerMate SP user instructions benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems In the interest of continuously improving the
Descriptive Technical Documentation. DTD no. 521-7135
Descriptive Technical Documentation - Model-dependent - DTD no. 521-7135 Model(s): PT 7135 C, PT 7136, PT 5135 C, PT 5136 14.10.2005, DE_en This information should not be duplicated or passed on without
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
SCORPION Z16040C Alarm Controller User Instructions
SCORPION Z16040C Alarm Controller User Instructions Thank you for choosing to purchase this micron security alarm controller. Micron product is manufactured to exacting quality standards. We understand
What you can expect from your Solar Hot Water System
Owner s Manual Your Solar Hot Water System Thank you for your investment in the FAFCO Solar Hot Water System. Since 1969 our goal has been to design, test, and produce solar heating systems that save you
CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions
Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments
Expert Report. History of the development of water level control in steam- and hot water boilers
Expert Report Dipl.-Ing. Jochen Loos Dipl.-Wirtschaftsing. (FH), Dipl.-Informationswirt (FH) Markus Tuffner, Bosch Industriekessel GmbH History of the development of water level control in steam- and hot
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU
Automatic Temperature Control Diagnosis and Repair Diagnosis of Automatic A/C Systems The most common automatic A/C system malfunctions tend to be the result of basic air conditioning problems. These problems
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION
KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION The digital chronothermostat Brahma Kronos series integrates
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
FT-100 Fire Training Fog Machine User Manual English
FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating
COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!
EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage
B/S/H/ Error codes and service programmes PH
1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E
F454. Web Server. User Manual 05/12-01 PC
F454 Web Server User Manual 05/2-0 PC 2 Web Server Contents Introduction and basic functions 5. Connection modes 6.. Connection to the data network 6..2 Remote connection 6.2 Using the Web Server with
Technical Information
Technical Information Interface with DDC 6 720 642 841-00.1RS Logamatic LON-Gateway For heating contractors during project planning 6 720 643 554 (11/2010) US/CA Contents Contents 1 Explanation of symbols
Contents. Introduction
TION Contents Introduction...1 Basics...2 Main Menu Structure...3 Time Schedule Menu...4 Settings Menu...5 Reports Menu...6 Date / Time Adjustment Menu...7 Introduction TION is an advanced control device
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
MP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
Porcia, 20 novembre 2012
1 2 PLZ RANGE 14-18-20 3 TECHNICAL NUMBERS 4 MAIN COMPONENTS CONTROL SAFETY HYDRONIC OUTLET WATER TEMPERATURE INLET WATER TEMPERATURE AIR OR WATER EXTERNAL TEMPERATURE FRESH AIR WITH PRESSURE DIFFERENTIAL
Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012
Operating instructions Optical distance sensor UK O1D100 O1D103 704991 / 00 08 / 2012 Contents 1 Preliminary note4 1.1 Symbols used 4 1.2 Warning signs used 4 2 Safety instructions 4 3 Functions and features
All About. Servicing. Service Tech Hand Book. 2010 Electrolux Home Products Inc. 10200 David Taylor Drive Charlotte, NC 28262
All About Servicing Service Tech Hand Book 2010 Electrolux Home Products Inc. 10200 David Taylor Drive Charlotte, NC 28262 Publication #5995588729 February 2011 Section 1 Basic Information Safe Servicing
HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1
--- OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM Serial number: Year: Please quote this number when contacting customer service!
Air-conditioning controller. User's Manual NRT 107 F031, F041 7000986003 R2. 7000986003 R2 Sauter Components
R Air-conditioning controller User's Manual NRT 107 F031, F041 7000986003 R2 - 3 - Table of contents 1 General information... 5 1.1 Introduction... 5 1.2 Safety instructions... 5 1.3 Key to the operating
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Digital timer thermosatat. isense. Installation and Service Manual 120666-AG
EN Digital timer thermosatat isense Installation and Service Manual 120666-AG Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5 2.2 Installation
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor User Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 2. Function Description 3 Definition
Technical Information
Date of last update: Jul-05 Ref: Application Engineering Europe OIL PRESSURE SAFETY CONTROL FOR SEMI-HERMETICS 1 Oil Pressure Differential Switches The oil pressure differential switch breaks the control
COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg
COMPTROL 5000 INDEX 52 Issue 5.99 AIR CONDITIONING MICROPROCESSOR STULZ GmbH, Hamburg OPERATING INSTRUCTIONS Contents Page INTRODUCTION... 4 NOTES ON SAFETY... 4 PAGE CODE... 4 DESCRIPTION OF THE CONTROLLER...
Article: 08090705 Version: 01.02. www.devi.com
Article: 08090705 Version: 01.02 www.devi.com GB User s Guide - devireg 550 Thermostat User s Guide - devireg 550 Thermostat About the thermostat Pages 2-5 Configurations Pages 6-9 Set weekday and clock
User manual. 086U6297 Rev. 6 EN
User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 6 EN If these instructions
Niko Home Control. Installation Manual
Niko Home Control Installation Manual Niko Home Control: Table of contents Warnings regarding installation...2 Guarantee provisions...3 CE...4 Key of symbols...5 1. Installation preparations...6 2. Controller...8