Rotary cam switches GX series Planet-SWITCH Planet-DIN Planet-LOGIC

Size: px
Start display at page:

Download "Rotary cam switches GX series Planet-SWITCH Planet-DIN Planet-LOGIC"

Transcription

1 Rotary cam switches GX series Planet-SWITCH Planet-DIN Planet-LOGIC % electricity

2 Rotary cam switches GX series Compact and finger safe (IP2 protection of contacts). Designed according to the latest technology in the switching device field and made of the best quality materials, these cam switches are characterised by high breaking capacity, long life (both mechanical and electrical), installation ease as well as compact size. The contacts are dual breaking and made of silver alloy. The terminals have cross-slotted captive screws and are self releasing. GX rotary cam switches can be used for isolation, motor control in AC3 and AC23 duties and electromagnetic load switching, AC5 duty. start disconnect switch reverse Available in four different ratings, 6, 2, 32 and 4A, and an assortment of versions. % electricity Front mounting version. Type: GX U. Pages 4 to 6. Door coupling version. Types: GX O68 GX O78. Page 8. Door-coupling version with red/yellow padlock handle system. Types: GX O88 GX 98. Page 8.

3 Front mounting version with red/yellow padlock system. Types: GX U25 GX U65. Page 7. Key operation version for 22mm central fixing. Type: GX U2. Page 7. Front-mounting version with handle operation for 22mm central fixing. Type: GX U. Page 7. Enclosure version with padlockable rotating handle. Type: GX P25. Page. Enclosure version Type: GX P. Page. Modular DIN rail mount version. Type: GX O48. Page 9. ORDER CODE STRUCTURE: G X U O RATING SCHEME VERSION OPTIONALS 6 A 2 A 32 A 4 A See page 2 U = front mounting O = door coupling See pages 4 to 8 Example of switch mounting for version U Example of switch mounting for version O

4 4 Rotary cam switches GX Series electric U version front mounting. ON/OFF switches AC size pkg ON/OFF SWITCHES. One-pole wafer scheme 9. GX6 9 U GX2 9 U GX32 9 U GX4 9 U Two-pole wafer scheme 9. GX6 9 U GX2 9 U GX32 9 U GX4 9 U Three-pole 2 wafers scheme. GX6 U GX2 U GX32 U GX4 U Four-pole 2 wafers scheme 92. GX6 92 U GX2 92 U GX32 92 U GX4 92 U General characteristics - 6 to 4A rated thermal current Ith ratings - Extended mechanical and electrical life - Switching angles: 3, 45, 6 and 9 - Silver-alloy dual-breaking contacts - IP4 front degree of protection (for IP65, see Optional below); IP2 protection of contacts - Operating temperature: -25 to +55 C - Legend marking is standard supplied as illustrated in the order code table; any other on request. Certifications and compliance Certifications obtained: culus. Compliant to standards: IEC/EN , IEC/EN 624-, IEC/EN Selection guide See page 4. Optional IP65 protection front plate: Add 5 at the end of the order code E.g. GX6 92 U 5. Enlarged front plate for GX6-GX2 (65x65mm instead of standard 48x48): Add H after the switch rating in the order code E.g. GX6H U. Enlarged front plate for GX32-GX4 (9x9mm instead of standard 65x65): Add H after the switch rating in the order code E.g. GX32H U. Example of U version switch mounting Accessories page page 2 Wiring diagrams page 3 Technical characteristics page 4

5 electric Rotary cam switches GX Series 5 U version front mounting. Changeover switches with position. Changeover switches without position AC size pkg CHANGEOVER SWITCHES WITH. One-pole wafer scheme 5. GX6 5 U GX2 5 U GX32 5 U GX4 5 U Two-pole 2 wafers scheme 52. GX6 52 U GX2 52 U GX32 52 U GX4 52 U Three-pole 3 wafers scheme 53. GX6 53 U GX2 53 U GX32 53 U GX4 53 U Four-pole 4 wafers scheme 75. GX6 75 U GX2 75 U GX32 75 U GX4 75 U CHANGEOVER SWITCHES WITHOUT. One-pole wafer scheme 54. GX6 54 U GX2 54 U GX32 54 U Two-pole 2 wafers scheme 55. GX6 55 U GX2 55 U GX32 55 U Three-pole 3 wafers scheme 56. GX6 56 U GX2 56 U GX32 56 U Four-pole 4 wafers scheme 69. GX6 69 U GX2 69 U GX32 69 U General characteristics - 6 to 4A rated thermal current Ith ratings - Extended mechanical and electrical life - Switching angles: 3, 45, 6 and 9 - Silver-alloy dual-breaking contacts - IP4 front degree of protection (for IP65, see Optional below); IP2 protection of contacts - Operating temperature: -25 to +55 C - Legend marking is standard supplied as illustrated in the order code table; any other on request. Certifications and compliance Certifications obtained: culus. Compliant to standards: IEC/EN , IEC/EN 624-, IEC/EN Selection guide See page 4. Optional IP65 protection front plate: Add 5 at the end of the order code E.g. GX6 75 U 5. Enlarged front plate for GX6-GX2 (65x65mm instead of standard 48x48): Add H after the switch rating in the order code E.g. GX6H 52 U. Enlarged front plate for GX32-GX4 (9x9mm instead of standard 65x65): Add H after the switch rating in the order code E.g. GX32H 52 U. Example of U version switch mounting Accessories page page 2 Wiring diagrams page 3 Technical characteristics page 4

6 6 Rotary cam switches GX Series electric U version front mounting. Motor switches Order Ith Max Front Q.ty Wt. code AC power plate per AC23A size pkg [A] [] [mm] n [kg] MOTOR SWITCHES. Reversing switches. Three-pole 3 wafers scheme. GX6 U GX2 U GX32 U GX4 U Pole-changing switches. 4 wafers scheme 3. GX6 3 U GX2 3 U GX32 3 U GX4 3 U Star-delta switches. 2 wafers scheme 2. GX6 2 U GX2 2 U Y GX32 2 U GX4 2 U pole motor reversing switches with spring return to. 3 wafers scheme 26. GX6 26 U GX2 26 U GX32 26 U General characteristics - 6 to 4A rated thermal current Ith ratings - Extended mechanical and electrical life - Switching angles: 3, 45, 6 and 9 - Silver-alloy dual-breaking contacts - IP4 front degree of protection (for IP65, see Optional below); IP2 contact degree of protection - Operating temperature: -25 to +55 C - Legend marking is standard supplied as illustrated in the order code table; any other on request. Certifications and compliance Certifications obtained: culus. Compliant to standards: IEC/EN , IEC/EN 624-, IEC/EN Selection See page 4. Optional IP65 protection front plate: Add 5 at the end of the order code E.g. GX6 U 5. Enlarged front plate for GX6-GX2 (65x65mm instead of standard 48x48): Add H after the switch rating in the order code E.g. GX6H U. Enlarged front plate for GX32-GX4 (9x9mm instead of standard 65x65): Add H after the switch rating in the order code E.g. GX32H U. Example of U version switch mounting U version front mounting. Voltmeter switches. Ammeter switches AC size pkg VOLTMETER SWITCHES. Phase-Neutral L-N/L2-N/L3-N 2 wafers scheme 68. GX6 68 U LN L2N L3N Phase-Phase L-L2/L2-L3/L3-L 2 wafers scheme 67. GX6 67 U L-L L2-L3 L3-L For 3 phase to phase voltage and 3 phase voltage readings 3 wafers scheme 66. GX6 66 U L-L2 L-N L2-L3 L3-L L2-N L3-N For phase voltage and 3 phase to phase voltage readings 3 wafers scheme 6. GX6 6 U LN L-L L2-L3 L3-L General characteristics - 6A capacity rating - Extended mechanical and electrical life - Switching angles: 3, 45, 6 and 9 - Silver-alloy dual-breaking contacts - IP4 front degree of protection (for IP65, see Optional below); IP2 contact degree of protection - Operating temperature: -25 to +55 C - Circuit schemes on page 2 - Legend marking is standard supplied as illustrated in the order code table; any other on request. Certifications and compliance Certifications obtained: culus. Compliant to standards: IEC/EN , IEC/EN 624-, IEC/EN Selection See page 4. Optional IP65 protection front plate: Add 5 at the end of the order code E.g. GX6 U 5. Enlarged front plate for GX6 (65x65mm instead of standard 48x48): Add H after the switch rating in the order code E.g. GX6H U. Example of U version switch mounting AMMETER SWITCHES. Direct L-L2-L3 current readings 5 wafers scheme 97. GX6 97 U L3 L2 L For L-L2-L3 readings via 3 CTs 3 wafers scheme 98. GX6 98 U L3 L2 L Accessories page page 2 Wiring diagrams page 3 Technical characteristics page 4

7 electric Rotary cam switches GX Series 7 U version front mounting with handle operation, for central 22mm fixing. ON/OFF switches U2 version front mounting with key operation, for central 22mm fixing. ON/OFF switches AC size pkg ON/OFF SWITCHES. One-pole wafer scheme 9. GX6 9 U 6.97 Two-pole wafer scheme 9. GX6 9 U 6. Three-pole 2 wafers scheme. GX6 U 6.6 Four-pole 2 wafers scheme 92. GX6 92 U 6.8 AC size pkg ON/OFF SWITCHES. One-pole wafer scheme 9. GX6 9 U Two-pole wafer scheme 9. GX6 9 U General characteristics - 6 to 4A rated thermal current Ith ratings - Extended mechanical and electrical life - Switching angles: 3, 45, 6 and 9 - Silver-alloy dual-breaking contacts - IP4 front degree of protection (for IP65, see Optional below); IP2 protection of contacts - Operating temperature: -25 to +55 C - Legend marking for U and U2 versions is only for reference while for U25 and U65 types standard supplied as illustrated in the order code table; any other on request. Certifications and compliance Certifications obtained: culus. Compliant to standards: IEC/EN , IEC/EN 624-, IEC/EN Selection See page 4. Optional IP65 protection front plate: Add 5 at the end of the order code E.g. GX6 92 U 5. Enlarged front plate for GX6-GX2 (65x65mm instead of standard 48x48): Add H after the switch rating in the order code E.g. GX6H U25. Enlarged front plate for GX32-GX4 (9x9mm instead of standard 65x65): Add H after the switch rating in the order code E.g. GX32H U25. Example of U25-U65 switch mounting Three-pole 2 wafers scheme. GX6 U Four-pole 2 wafers scheme 92. GX6 92 U U25-U65 versions front mounting with red/yellow padlock system. ON/OFF switches AC size pkg ON/OFF SWITCHES. Three-pole 2 wafers scheme. GX6 U GX2 U GX32 U GX4 U Four-pole 2 wafers scheme 92. GX6 92 U GX2 92 U GX32 92 U GX4 92 U Accessories page page 2 Wiring diagrams page 3 Technical characteristics page 4

8 8 Rotary cam switches GX Series electric O88-98 versions door coupling with red/yellow padlock system. ON/OFF switches O68-78 versions door coupling. ON/OFF switches AC size pkg ON/OFF SWITCHES. Three-pole 2 wafers scheme. GX6 O GX2 O GX32 O GX4 O Four-pole 2 wafers scheme 92. GX6 92 O GX2 92 O GX32 92 O GX4 92 O AC size pkg ON/OFF SWITCHES. Three-pole 2 wafers scheme. GX6 O GX2 O GX32 O GX4 O Four-pole 2 wafers scheme 92. GX6 92 O GX2 92 O GX32 92 O GX4 92 O General characteristics - 6 to 4A rated thermal current Ith ratings - Extended mechanical and electrical life - Switching angles: 3, 45, 6 and 9 - Silver-alloy dual-breaking contacts - IP4 front degree of protection (for IP65, see Optional below); IP2 contact degree of protection - Operating temperature: -25 to +55 C - Suitable for screw fixing or mounting on 35mm DIN rail (EN 522) - Legend marking is standard supplied as illustrated in the order code table; any other on request. Certifications and compliance Certifications obtained: culus. Compliant to standards: IEC/EN , IEC/EN 624-, IEC/EN Selection See page 4. Optional IP65 protection front plate: Add 5 at the end of the order code E.g. GX Enlarged front plate for GX6-GX2 (65x65mm instead of standard 48x48): Add H after the switch rating in the order code E.g. GX6H O88. Enlarged front plate for GX32-GX4 (9x9mm instead of standard 65x65): Add H after the switch rating in the order code E.g. GX32H O88. Example of O version switch mounting Accessories page page 2 Wiring diagrams page 3 Technical characteristics page 4

9 electric Rotary cam switches GX Series 9 O48 version modular, 35mm DIN rail mounting. ON/OFF switches. Changeover switches. Voltmeter switches. Ammeter switches AC size pkg ON/OFF SWITCHES. One-pole 3 wafers scheme 9. GX6 9 O Two-pole 3 wafers scheme 9. GX6 9 O Three-pole 3 wafers scheme. GX6 O Four-pole 3 wafers scheme 92. GX6 92 O General characteristics - 6A rated thermal current Ith ratings - Extended mechanical and electrical life - Switching angles: 3, 45, 6 and 9 - Silver-alloy dual-breaking contacts - IP4 front degree of protection ; IP2 contact degree of protection - Operating temperature: -25 to +55 C - Suitable for screw fixing or mounting on 35mm DIN rail (EN 522) - Legend marking is standard supplied as illustrated in the order code table; any other on request. Certifications and compliance Certifications obtained: culus. Compliant to standards: IEC/EN , IEC/EN 624-, IEC/EN Selection guide See page 4. CHANGEOVER SWITCHES WITH. One-pole 3 wafers scheme 5. GX6 5 O Two-pole 3 wafers scheme 52. GX6 52 O Three-pole 3 wafers scheme 53. GX6 53 O Four-pole 4 wafers scheme 75. GX6 75 O VOLTMETER SWITCHES. Phase-Neutral L-N/L2-N/L3-N 3 wafers scheme 68. GX6 68 O48 LN 6.5 L2N L3N Phase-Phase L-L2/L2-L3/L3-L 3 wafers scheme 67. GX6 67 O48 L-L2 6.5 L2-L3 L3-L For 3 phase to phase voltage and 3 phase voltage readings 3 wafers scheme 66 GX6 66 O48 L-L2 L-N 6.75 L2-L3 L2-N L3-L L3-N AMMETER SWITCHES. Direct L-L2-L3 current readings 5 wafers scheme 97. GX6 97 O L3 L2 L For L-L2-L3 readings via 3 CTs 4 wafers scheme 98. GX6 98 O L3 L2 L Accessories page page 2 Wiring diagrams page 3 Technical characteristics page 4

10 Rotary cam switches electric GX Series P version in enclosure with rotating handle. On/Off switches. Changeover switches Orde code Rated Housing Qty Wt current size per AC pkg ON/OFF SWITCHES. Three poles - scheme. GX6 P 6 9x9.26 GX2 P 2 9x9.26 GX32 P 32 x.44 GX4 P 4 x.44 ON/OFF SWITCHES. Four poles - scheme 92. GX6 92 P 6 9x9.26 GX2 92 P 2 9x9.26 GX32 92 P 32 x.44 GX4 92 P 4 x.44 CHANGEOVER SWICTHES. Three poles - scheme 53. GX6 53 P 6 9x9.26 GX2 53 P 2 2 9x9.26 GX32 53 P 32 x.44 GX4 53 P 4 x.44 CHANGEOVER SWICTHES. Four poles - scheme 75. GX6 75 P 6 9x9.26 GX2 75 P 2 2 9x9.26 GX32 75 P 32 x.44 GX4 75 P 4 x.44 General characteristics 6 to 4A rated thermal current ratings Extended mechanical and electrical life Switching angles: 3, 45, 6 and 9 Silver-alloy dual-breaking contacts IP65 degree of protection Operating temperature: -25 to +55 C Top and bottom entry: 4 PG6 threaded knockouts for 9x9mm types and 4 PG2 for xmm Legend marking is standard supplied as illustrated in the order code table; any other on request. Certifications and compliance Certifications obtained: culus. Compliant to standards: IEC/EN , IEC/EN 624-, IEC/EN Selection guide See page 4. P version in enclosure with rotating handle. Motor switches Order Ith Max Housing Qty Wt. code AC power size per AC23A pkg [A] MOTOR SWITCHES. Three-pole reversing switches - scheme. GX6 P x9.27 GX2 P x9.27 GX32 P 32 5 x.482 GX4 P x.482 P version in enclosure with padlockable rotating handle. On/Off switches Orde code Rated Housing Qty Wt current size per AC pkg. ON/OFF SWITCHES. Three poles - scheme. GX6 P25 6 9x9.33 GX2 P25 2 9x9.33 GX32 P25 32 x.43 ON/OFF SWITCHES. Four poles - scheme 92. GX6 92 P25 6 9x9.34 GX2 92 P25 2 9x9.34 GX32 92 P25 32 x.44 Accessories page page 2 Wiring diagrams page 3 Technical characteristics page 4

11 electric Rotary cam switches Accessories for GX series Accessories for GX switches 7 AO4-7 AR4-7 AR24 7 AR24-7 AR224 7 APRBP Order Description Q.ty Weight code per pkg n. [kg] Black operating handle❶. 7 AO4 48x48mm front plate.5 7 AR4 65x65mm front plate. 7 AR24 9x9mm front plate.5 Black operating lever❶. 7 AR24 65x65mm front plate.9 7 AR224 9x9mm front plate.38 Adjustable door-coupling extension shaft. 7mm long max❶. 7 APRBP For GX6 to GX4.27 IP4 face plates❶. GX M 48x48mm blank face plate. GX M2 65x65mm blank face plate.27 IP4 face plates with legend plates. GX M5 48x48mm blank face plate.3 with legend plate GX M6 65x65mm blank face plate.29 with legend plate Padlockable handles❶. GX A 48x48mm yellow/red.3 padlockable handle for GX6-GX2 GX AH 65x65mm yellow/red.47 padlockable handle for GX6-GX2 GX A 65x65mm yellow/red.47 padlockable handle for GX32-GX4 ❶ Also suitable for GN series. GX M - GX M2 GX M5 - GX M6 GX A - GX AH - GX A

12 2 [mm] electric Rotary cam switches GX series Front mounting A B H -5 Type A B C D E F G H K M N D D2 L [mm] wafer 2 wafers 3 wafers 4 wafers 5 wafers 6 wafers GX6 U GX6 U ❶ N GX2 U D C GX2 U ❶ GX32 U E L M G F GX32 U ❶ GX4 U GX4 U ❶ ❶ Padlockable handle D2 D Door coupling O version L S -5 E K M P D DIN35 EN52 N C A D D2 D G F D2 Type A C D E F G K M N O P S D D2 GX6 O GX6 O88 48 ❶ GX2 O GX2 O88 48 ❶ GX32 O GX32 O88 65 ❶ GX4 O GX4 O88 65 ❶ L [mm] wafer 2 wafers 3 wafers 4 wafers 5 wafers 6 wafers ❶ Padlockable handle. Mounting in enclosure Type N of wafers Enclosure Protection Cable glands L L size A A C C D F M N L L degree GX GX x IP65 4 PG 6 GX GX x IP65 4 PG PG Flush mounting Ø 22mm Flush mounting Ø 22mm Modular mounting -5-5 L DIN35 EN522 Ø 22.5 L Ø 22.5 L Type L [mm] wafer 2 wafers 3 wafers 4 wafers GX Type L [mm] wafer 2 wafers 3 wafers 4 wafers GX Type L [mm] 3 wafers 4 wafers 5 wafers GX

13 electric Wiring diagrams Rotary cam switches. Circuit schemes One-pole ON/OFF switch 9 - Two-pole ON/OFF switch - Three-pole ON/OFF switch 92 - Four-pole ON/OFF switch 5 - -pole changeover switch with pole changeover switch with Number of wafers: Switching angle: 6 Number of wafers: Switching angle: 6 Number of wafers: 2 Switching angle: 6 Number of wafers: 2 Switching angle: 6 Number of wafers: Switching angle: 6 Number of wafers: 2 Switching angle: pole changeover switch with 75-4-pole changeover switch with pole changeover switch without 55-2-pole changeover switch without pole changeover switch without 2 Number of wafers: 3 Switching angle: 6 Number of wafers: 4 Switching angle: 6 Number of wafers: Switching angle: 9 Number of wafers: 2 Switching angle: 9 Number of wafers: 3 Switching angle: pole changeover switch without - 3-pole reversing switch 3 - Pole-changing switch with (Dahlander) Number of wafers: 4 Switching angle: Star-delta switch Number of wafers: 3 Switching angle: 6 Number of wafers: 4 Switching angle: Reversing switch, spring return to Y 2 Number of wafers: 4 Switching angle: 6 Number of wafers: 3 Switching angle: Pole-changing switch with reversing (Dahlander) 2 2 Number of wafers: 6 Switching angle: Ammeter switch direct reading or via current transformer 68 - Phase-neutral voltmeter switch 67 - Phase-phase voltmeter switch L3 L LN L2N L3N L-L2 L2-L3 L3-L L2 Number of wafers: 5 Switching angle: 9 Number of wafers: 2 Switching angle: 3 Number of wafers: 2 Switching angle: Phase-phase phase-neutral voltmeter changeover 6 - Changeover switch phase phase-neutral, 3 phase-phase voltages 98 - L-L2-L3 current changeover switch L-L2 L-N L2-L3 L2-N L3-L L3-N LN L-L2 L2-L3 L3-L L3 L2 L Number of wafers: 3 Switching angle: 3 Number of wafers: 3 Switching angle: 3 Number of wafers: 3 Switching angle: 9

14 4 Technical characteristics electric Rotary cam switches SELECTION GUIDE The choice of a rotary cam switch and the relative type are based on the functional diagram and the type of application as well. IEC standards provide a comprehensible and quick classification of the most frequent utilisation categories: AC: Connection and disconnection of non-inductive or slightly inductive loads (cosϕ.95) AC2: Resistance furnaces AC3: Starting and switching off motors during running AC23A: Switching of motor loads or other highly inductive loads AC5: Control of electromagnetic loads For DC applications, the rotary cam switches are used for the switching of minor loads or in control circuits, such as: DC3: Control of electromagnets DC2A: Switching of resistive loads DC23: Switching of highly inductive loads Other prescriptions and recommendations concerning the use of cam switches as auxiliary equipment of electrical machines are given in IEC/EN 624- standards and specifically as given under utilisation. UTILISATION MAIN SUPPLY DISCONNECTING SWITCH WITH EMERGENCY-STOP OPERATION: Red operating handle with yellow background Lockable in open position (OFF). EMERGENCY-STOP SWITCH Red operating handle with yellow background Independent operation and the breaking of the load circuit of switching devices before the opening of its main contacts Rated capacity is to sufficient in order to break the sum of the rated operating currents of all the connected equipment Breaking capacity equal to the current of the largest motor when stalled (locked rotor) together with the total of the normal running currents of the other motors or loads. MAIN SUPPLY DISCONNECTING SWITCH Used to disconnect all live electrical equipment from the power supply circuit Contact clearance distance is to comply with IEC/EN standards Provided with a means in order to be locked in the OFF position Selection of current breaking according to AC and AC2 utilisation categories. Operational characteristics ❶ Valid for systems with earthed neutral, overvoltage category III, pollution degree 3. TYPE Rated insulation voltage ❶ Ui IEC/EN UL/CSA V V Rated impulse withstand voltage ❶ Uimp IEC/EN kv Rated thermal current Ith IEC/EN A Maximum fuse size for short-circuit protection ka A Ie (gg) 25kA A 5kA A 63kA A Short-time withstand current Icw sec A Rated operational current Ie AC/AC2A (IEC/EN) A V A AC5 (IEC/EN) 22/23V 38/4V 66/69V A A A Motor power for switches in AC utilisation categories AC3 (IEC/EN) 22-24V 3 phases 38-44V 5-69V phase (2 poles) V 22/24V 38/44V AC23A (IEC/EN) 22/24V 3 phase 38/44V 5/69V phase (2 poles) V 22/24V 38/44V DOL motor powers for switches (UL/CSA) 2V Hp 3 phase 24V 48V 6V Hp Hp Hp Mechanical life cycles Conductor cross section max. r/f 2-mm 2 2-AWG r: rigid min. r/f f: flexible 2-mm 2 2-AWG GX6... GX2... GX32... GX x 6 5x 6 5x 6 5x 6 2.5/ /2.5 /6 /6 4/4 4/4 8/ 8/.5/.5.5/.5.5/.5.5/.5 2/2 2/2 6/6 6/6

15 Rotary cam switches, GX series Special circuit scheme form D A 9 3 C B Plate pos. indication C D 2 A 2 3 B Front plate 2 Type: X X X X X X X Overlapping Closed contact Open/ Closed Spring contacts in 2 or more passing contact return positions contact Date: Scheme: Customer:

16 new 24 Mini-contactors, BGF series Joysticks, push-push and triple-touch buttons Digital multimeters DMK2, DMK25 and DMK5 series Current transformers, DM...T series Planet-SWITCH Motor protection circuit breakers Switch disconnectors Contactors Motor protection relays Electromechanical starters Push-buttons and selectors Position and safety switches Rotary cam switches Planet-DIN Modular contactors Time relays Protection relays Level controls Earth leakage relays Planet-LOGIC Digital metering instruments and current transformers Soft starters AC motor drives Automatic power factor regulators Automatic battery chargers Automatic transfer switches The products described in this documentation are subject to be revised or improved at any moment. Catalogue descriptions and details, such as technical and operational data, drawings, diagrams and instructions, etc., do not have any contractual value. In addition, products should be installed and used by qualified personnel and in compliance with the regulations in force for electrical systems in order to avoid damages and safety hazards. AC motor drives, VFS series Automatic power factor regulators LOVATO ELECTRIC S.P.A. CONTROL SOLUTIONS FOR INDUSTRY Via Don E. Mazza GORLE BG, Italy Tel info@lovatoelectric.com Sales Department: Tel Fax PD GB 7 4 % electricity

Products and solutions for pumping, irrigation and piping

Products and solutions for pumping, irrigation and piping Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

Products and solutions for machine builders (OEM) 100% electricity

Products and solutions for machine builders (OEM) 100% electricity Products and solutions for machine builders (OEM) 100% electricity www.lovatoelectric.com Tra dition and innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters

More information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

General Informations 2 Technical data 3 Basic designs 4-8

General Informations 2 Technical data 3 Basic designs 4-8 Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Energy quality analysis. Load protection. Renewable energy. On request or periodic load. management

Energy quality analysis. Load protection. Renewable energy. On request or periodic load. management Energy management Energy management Energy quality analysis Load protection Energy quality control v t Non-priority load management On request or periodic load management Renewable energy Power factor

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time) 100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

Energy meters For an efficient control of energy consumption

Energy meters For an efficient control of energy consumption Energy meters Energy meters For an efficient control of energy consumption In a modern world in which energy must be monitored and controlled in the most efficient way possible, LOVATO Electric presents

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated

Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated Technical catalogue - Ordering Codes SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated New SACE Tmax XT. Simply XTraordinary. Today a highly advanced range of circuit-breakers

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

THERMAL RELAYS, MOTORSTARTERS

THERMAL RELAYS, MOTORSTARTERS THERMAL RELAYS, MOTORSTARTERS MH mini thermal relay plugged version H0K thermal relay with adapter H0K thermal relay plugged version T I thermal relay plugged version H thermal relay with current transformer

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

ASSEMBLED SOCKET-COMBINATIONS

ASSEMBLED SOCKET-COMBINATIONS ASSEMBLED SOCKETCOMBINATIONS Enclosure extra strong, schockresistant easily open, it provides a comfortable mount it can be connected across a cable gland it consists of a 35 mm mounting rail Window 6

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation

More information

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C .1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

High-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution

High-Voltage Circuit-Breakers 3AP1/2 72.5 kv up to 550 kv. Power Transmission and Distribution High-Voltage Circuit-Breakers AP/ 7.5 kv up to 550 kv Power Transmission and Distribution The AP/ High-Voltage Circuit-Breakers Now Applicable for 550 kv Decades of our experience in high-voltage switching

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

THE ADVANTAGES ARE YOURS

THE ADVANTAGES ARE YOURS THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Breakers and Switches. Switches Change-over, bypass and transfer switches

Breakers and Switches. Switches Change-over, bypass and transfer switches Breakers and Switches Switches Change-over, bypass and transfer switches Change-over, bypass and transfer switches Product overview, features Product overview 4 Features 6 Technical data Manual / motorized

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information