1 0 0/2 Measuring Devices Introduction 0/4 7T5 8 time and puse counters 0/6 7T5 5 and 7T5 6 time counters for front-pane mounting 0/8 7T 0 anaog measuring devices 0/0 7T digita measuring devices 0/ 7T 30 mutimeters 0/6 7T 3 muticounters 0/22 7T 4 E-counters, singe-phase 0/24 7T 5 E-counters, three-phase 0/28 7T 6 E-counters, three-phase, instabus X EIB 0/32 7T 390 A server 0/35 7T 2 current transformers 0 0/

2 Measuring Devices Introduction Overview Devices Appication Standards Usage on-res. bdgs. Res. bdgs. Industry Time and puse counters 7T5 80 and 7T5 82 time counters 7T5 8 and 7T5 83 puse counters Monitoring of operating hours and starting operations of devices or pants IEC , E (VDE 0435 T 30) Time counters for front-pane mounting 7T5 5 and 7T5 6 Monitoring of operating hours of devices or pants IEC , E (VDE 0435 T 30) Anaog measuring devices 7T 0 For measuring votages and currents, for monitoring input and output currents or device currents IEC , E Digita measuring devices 7T For measuring votages and currents, for monitoring input and output currents or device currents DI 4375-, DI Mutimeters 7T 30 For the dispay and assessment of 23 eectrica measured vaues in switchgear, incoming suppies and outgoing feeders IEC , E IEC 600-, DI E 600- (VDE04T) Muticounters 3T 3, 3T 34, 3T 35 For the dispay and assessment of 35 eectrica measured vaues and consumption vaues in switchgear, incoming suppies and outgoing feeders IEC , E IEC 600-, E 600- (VDE 04 T ) IEC , E (VDE 048 T 3-2) 0/2 Siemens ET B T 2005

3 Overview Definitions I e = Rated operationa current U e = Rated operationa votage I c = Rated contro suppy current U c = Rated contro suppy votage P s = Rated operationa capacity MW = 8 mm moduar width Measuring Devices Introduction Devices Appication Standards Usage E-counters, singe-phase 7T 4 E-counters, three-phase 7T 50, 7T 5, 7T 52 E-counters, three-phase, instabus X EIB 7T 6 A server 3T 390 Current transformers 7T 2 For the measurement of Wh in singephase systems, e.g. in industria pants, offices and apartments in apartment houses For the measurement of Wh in singe and three-phase systems, e.g. in industria pants, offices and apartments in apartment houses With instabus X EIB interface, for the measurement of Wh in singe and three-phase systems, e.g. in industria pants, offices and apartments in apartment houses Wordwide data communication with measuring devices using A/Internet For non-contact measuring of primary currents of a 3-phase system IEC , E (VDE 048 T 3-) IEC , E (VDE 048 T 3-2) IEC 600-, E 600- (VDE 04 T ) IEC , E (VDE 048 T 3-) IEC , E (VDE 048 T 3-2) IEC 6036 E 6036 (VDE 048 T7) on-res. bdgs. Res. bdgs. Industry IEEE 802 IEC , E (VDE 044 T 44-) Siemens ET B T /3

4 Measuring Devices 7T5 8 time and puse counters Overview The counters are designed for instaation in switching, contro and distribution boards and can be snapped onto standard mounting rais 35 mm acc. to E Function Time counters count the time in hours with an accuracy of two decima paces (hundredths of hours). The puse counter adds the number of puses, e.g. the maing operations of devices. In the case of eectronic counters, the counting resut is saved indefinitey in the event of a power faiure (EEPROM). On recovery of the power, the counting is continued from the saved vaue. Technica specifications Data acc. to DI VDE , E T5 80 7T T T T T5 807 Rated contro suppy votage U c V AC V DC Operating range at 50/60 Hz U c Rated frequency Hz Rated power dissipation P v VA < < 2 Method of operation counting of hours Dispay drum-type register h Terminas ± screw (Phiips) Conductor cross-sections rigid mm 2.5 fexibe with seeve, min. mm Permissibe ambient temperature C Degree of protection acc. to E IP20 Protection cass acc. to E II Permissibe humidity % < 80 Data acc. to DI VDE , E T5 8 7T5 82 7T5 84 7T5 82 7T T T5 833 Rated contro suppy votage U c V AC V DC Operating range at 50/60 Hz U c Rated frequency Hz 50/60 Rated power dissipation P V VA < < 2 < Method of operation counting of puses hours puses Dispay drum-type register CD h Counting frequency Hz 0 0 Puse duration ms Resetting eectrica mechanica Terminas ± screw (Phiips) Conductor cross-sections rigid mm 2.5 fexibe with seeve, min. mm Permissibe ambient temperature C Degree of protection acc. to E IP20 Protection cass acc. to E II Permissibe humidity % < 80 0/4 Siemens ET B T 2005

5 Seection and ordering data I2_289 Measuring Devices 7T5 8 time and puse counters U c Frequency MW Order o. Weight item V Hz g Items Time counters Mechanica register, dispay h without resetting DC 2 7T AC 50 7T AC 7T AC 7T AC 60 7T AC 7T T5 80 Puse counters Mechanica register, dispay without resetting DC 2 7T AC 50/60 7T AC 7T Eectronic time counters CD h without resetting DC, AC 50/60 2 7T with eectrica resetting DC, AC 50/60 7T with eectrica and mechanica resetting DC, AC 50/60 7T Eectronic puse counter 7T5 823 CD dispay with eectrica and mechanica resetting DC, AC 50/60 2 7T Dimensiona drawings Schematics 7T5 80 7T5 82 Connections 7T T T T T5 80 7T T5 8 7T5 82 7T T T5 82 7T T5 84 7T T T T T5 82 7T T5 8 2(+) 2() 7T5 82 7T5 84 3(-) 3() 45 7T5 82 7T T T5 833 ` ` ` ` + J! " $ $ = + J 4 A I A J! " & & = PS*/ P. unit Eectronic counters A power suppy is required at terminas and 3 so that the device can continuousy show the measured vaue. Once termina 3 is suppied with votage (for DC "+"), the counting procedure starts. If termina 4 is suppied short-time with votage (for DC "+"), the counter is reset. In the event of a power faiure, the counting resut is indefinitey stored in EEPROM. On recovery of the power, the counting is continued from the saved vaue. * You can order this quantity or a mutipe thereof. Siemens ET B T /5

6 Measuring Devices 7T5 5 and 7T5 6 time counters for front-pane mounting Appication Areas of appication are time and puse recording for switchgear cabinets, contro and mechanica engineering, e.g. boiers, machine toos or compressors. Preventive maintenance Time counters provide support when panning preventive maintenance. In-time and reguar maintenance is the best protection against unexpected shutdowns and ensures high pant avaiabiity. Function Time counters count the time in hours with an accuracy of two decima paces (hundredths of hours). Technica specifications Data acc. to DI VDE , E T T5 50 7T T T T5 505 Rated contro suppy votage U c V AC V DC Operating range U c Rated frequency Hz Rated power dissipation P V VA < Method of operation counting of hours Dispay drum-type register h Puse duration puse ength, puse ms 50 interva Front-pane mounting Switchboard cutout without cover 55 mm 55 mm mm mm with cover 55 mm 55 mm Ø mm Terminas ± screw (Phiips) Conductor cross-sections rigid mm 2.5 fexibe with seeve, min. mm Permissibe ambient temperature C Degree of protection acc. to E front pane IP65 instaation with sea IP43 terminas IP20 Protection cass acc. to E II Permissibe humidity % < 93 Data acc. to DI VDE , E T T5 60 7T T T5 604 Rated contro suppy votage U c V AC V DC Operating range U c Rated frequency Hz Rated power dissipation P V VA < Method of operation counting of hours Dispay drum-type register h Puse duration puse ength, puse ms 50 interva Front-pane mounting Switchboard cutout mm mm Terminas ± screw (Phiips) Conductor cross-sections rigid mm 2.5 fexibe with seeve, min. mm Permissibe ambient temperature C Degree of protection acc. to E front pane IP52 terminas IP00 Protection cass acc. to E II Permissibe humidity % < 93 0/6 Siemens ET B T 2005

7 Seection and ordering data 7T T5 600 Dimensiona drawings Time counters 7T5 5 7T5 6 Schematics Connections Measuring Devices 7T5 5 and 7T5 6 time counters for front-pane mounting U c Frequency MW Order o. Weight item PS*/ P. unit V Hz g Items mechanica register, dispay h, for front-pane mounting, front frame 48 mm x 48 mm DC 7T AC 50 7T AC 7T AC 7T AC 60 7T AC 7T for front-pane mounting, front frame 72 mm x 72 mm with narrow frame according to DI DC 2 7T AC 50 7T AC 7T AC 60 7T AC 7T Cover for 7T5 5 time counter 55 mm 55 mm 7T Seaing ring for 7T9 020 cover IP 43-instaation in switchboards with smooth surfaces set ( set = 5 pcs) 7T set Termina cover for 7T5 6 time counter degree of protection IP20 7T T5 5, 7T * You can order this quantity or a mutipe thereof. Siemens ET B T /7

8 Measuring Devices 7T 0 anaog measuring devices Overview These devices for measuring votages and currents can be used for monitoring input and output currents or device currents. They are suitabe for direct connection in a singe-phase networ or, together with a measuring seector switch, for three-phase networs. Depending on the transformer, the ammeter for transformer connection can be fitted with interchangeabe scaes of 60, 00, 250, 400, 600 and 000 A AC. Main features of the devices are: extensive scae, continuous overoad up to 20 % Technica specifications Data acc. to E T 000 7T 0. 7T 020 Measuring ranges direct measurement V AC A AC A AC A AC transformer measurement A AC /5 Max. permissibe measuring frequency Hz Dispay pointer Measuring accuracy at 23 ± C % 3.5 Rated operationa capacity P s VA < 2 <. Temperature infuence %/ C 0.03 Overoad capabiity continuous.2 U meas.2 I meas short-time for s 2 U meas 0 I meas Test votage 50 Hz, min V > 2 Terminas +/- screw (Pozidrive) 2 Conductor cross-sections rigid, max. mm 2 x6/2x4 25 / 2 6 x6/2x4 fexibe with seeve, min. mm Permissibe ambient temperature C Degree of protection IP20 Seection and ordering data Anaog votmeter U c U meas I meas MW Order o. Weight item PS*/ P. unit V AC V AC A AC g Items T T 000 Anaog ammeter for direct connection T T T Anaog ammeter for transformer connection with AC scae 0 to 50 A /5 4 7T Changeabe scaes for 7T 020 ammeter easy on-site repacement 60 7T T T T T T T9 00 Dimensiona drawings 7T 000 7T 00, 7T 0, 7T 02, 7T 020 Schematics Connections 7T 000 7T 0., 7T I2_ /8 Siemens ET B T 2005 * You can order this quantity or a mutipe thereof.

9 Overview These devices for measuring votages and currents can be used for monitoring input and output currents or device currents. They are suitabe for direct connection in a singe-phase networ or, together with a measuring seector switch, for three-phase networs. The measuring ranges of the ammeter are set at the device with a coding switch. Technica specifications Measuring Devices 7T digita measuring devices Function Range seector switch for 7T 20 digita ammeter I2_0083b! " Direct measurement A AC 0 Transformer measurement /5A AC /5A AC /5A AC /5A AC /5A AC /5A AC 0 50/5A AC /5A AC 250/5A AC 400/5A AC 500/5A AC 600/5A AC 800/5A AC 999/5A AC Data in compiance with DI and DI T 0 7T 20 Rated contro suppy votage U c V AC 230 Operating range U c Rated frequency Hz Rated operationa capacity P s VA < 2 Measuring range votage direct measurement V AC current direct measurement A AC direct transformer measurement A AC /5 Dispay 3 EDs red; height 0 mm votage votage > 600 V HHH votage 2 V current direct current > 20 A HHH current transformer > 5 A HHH direct current < 0.4 A current transformer < 0. A Measuring cyce /s 4 times Measuring accuracy at 23 C % ±0.5 ± digit Temperature infuence %/ C 0.03 Overoad capabiity votage continuous V 720 short-time for s V 780 current continuous, direct A 22 continuous transformer A 5.5 short-time for s, direct A 200 short-time for s, transformer A 50 Eectrica isoation cearances mm 3.5 creepage distances in the device mm creepage distances on the printed board printed boards not instaed mm Test votage 50 Hz, min V Terminas +/- screw (Pozidrive) Conductor cross-sections rigid, max. mm 2 x6/2x4 fexibe with seeve, min. mm Permissibe ambient temperature C Degree of protection IP Siemens ET B T /9

10 Measuring Devices 7T digita measuring devices Seection and ordering data Digita votmeter U c U meas I meas MW Order o. Weight item PS*/ P. unit V AC V AC A AC g Items T Digita ammeter for direct and transformer connection T transformer/5 Dimensiona drawings 7T 0, 7T 20 Schematics Switching exampes Digita votmeter Digita ammeter! 8 ) +! 8 ) +! 8 ) +! " #! " #! " # % 6 % &! # =, EHA? J? A? JE F J ) % 6, EHA? J? A? JE B@ EBBA HA JF D = I A I F J ) % &! $ = % 6 6 H= I B H A H? A? JE 6 H= I B H A HU # ) % &! % = 0/0 Siemens ET B T 2005 * You can order this quantity or a mutipe thereof.

11 Overview A required measuring vaues of an instaation ceary visibe at a gance Innovative matrix seection of assignment and seection of measurement data of the dispay registers For direct connection 63 A or for transformer /A or /5A For transformer primary current of 0 to 5000 A. Input is in 5 A increments Size, mm high, attractive green 7-segment dispay for measured vaues Ceary recognizabe orange text dispay of units assigned to the dispays where the measured vaue appears Representation of measured vaues on 5 tripe 7-segment dispays and an auxiiary 7-segment dispay for input of primary current. Detection of connection errors (phase transposition) With error detection in the case of incorrect connection Measuring accuracy for votage, current and output: 2 % digit Appication Extremey compact mutifunction dispay for direct or transformer connection in a three-phase networ with star-deta measurement for the dispay of up to 3 different eectrica measured vaues in a switchgear or incoming or outgoing feeders. A specia feature is the anaysis of the different oads on the phases. Phase dispacement, unsymetrica or unbaanced oads can cause partia overoads. In this case, the mutimeter offers a range of different options to combine measured vaues and assess them. Function Votage measurement The mutimeter measures the deta votages against 2; 2 against 3 and 3 against or the star votages, 2, 3 against. Readout data Of the foowing 23 options, you can continuousy dispay 5 indicated vaues. umber Measured vaue Dispay Unit Assignment Active power D W 2 Votage D V 3 Current D A 4 Apparent power D VA 5 p. f. D p. f. 6 Votage D V 2 7 Active power D2 W 2 8 Votage D2 V 2 9 Current D2 A 2 0 Apparent power D2 VA 2 p. f. D2 p. f. 2 2 Votage D2 V Active power D3 W 3 4 Votage D3 V 3 5 Current D3 A 3 6 Apparent power D3 VA 3 7 p. f. D3 p. f. 3 8 Votage D3 V 3 9 Active power D5 W S 20 Apparent power D, D2, D3, VA S D5 2 Reactive power D5 var S 22 Frequency D4 Hz S 23 p. f. D, D2, D3, p. f. S D4 2 set vaues are aso indicated 24 Transformer setting D5 CT/A / or /5 25 Transformer setting D5 CT/A Measuring Devices 7T 30 mutimeters S symbo for the 3-phase system This indicates that a physica units shown under this symbo are aways 3-phase. Dispay The mutimeters have a covered brighty it ED dispay. The measured vaues are indicated on an -mm high, green, 7-segment ED, the physica units are indicated on an orange ED. Both coors are easier to read than the previousy used red ED. Capacitive oads are automaticay indicated by a capacitor, inductive oads by a coi. Matrix seection Conventiona measuring instruments usuay provide votage, current or other simiar vaues for three phases. Mutimeters with their matrix seection are consideraby more fexibe and more universa. The 3-fod indications are seected using the rotary and the desired indications confirmed with O. This is foowed by the horizonta seection e.g. W V A or p. f., and then the vertica seection, e.g. -2 S. Your matrix seection is set. The vertica data on the dispay can be assigned to any measured vaue in the horizonta data. The etters M and are automaticay assigned according to measuring range, i.e. measured vaue, e.g.: W or MW. Capacitive oads are automaticay indicated by a capacitor, inductive oads by a coi. The foowing diagram shows an exampe of what your matrix seection might oo ie.,!!! & " =!! M W V A COS M W V A COS M W V A COS W D D2 D3 M W V A R CT/A W 2 D5 A H Z W 3 C O S D4 C O S O I2_64 O I2_ Siemens ET B T /

12 Measuring Devices 7T 30 mutimeters Technica specifications Data in compiance with DI 4375-, DI and E 600-7T 300 7T 30 7T 302 Suppy Rated contro suppy votage U c V AC 230 Operating range U c Rated frequency Hz 50 Frequency range Hz Rated power dissipation VA ˆ0 Overoad capabiity Votage continuous: phase/phase V 480 second: phase/phase V 800 continuous: phase/ V 276 second: phase/ V 460 Current continuous A s A 0 0 ms A 000 Measuring input Type of connection direct transformer / A or /5 A Votage U e phase/phase V 400 phase/ V 230 Operating range votage phase/phase V phase/ V Current I e A 63 or 5 Operating range current A Transformer current primary current of the transformer A smaest input step A 5 Frequency Hz 50 Operating range frequency Hz Dispay Connection errors inverted phases Err Votage: 3 dispays, 3-digit deta 2, 2 3, 3 V star / 2/ 3/ V votage > 480/276 V HHH votage 87/50 V Current: 3 dispays, 3-digit 2 3 A or A or x transformer conversion ratio for current > 76;.2 or HHH 6 A x transformer conversion ratio for current < 0.; 0.0 A x transformer conversion ratio Frequency: dispay, 3-digit S Hz Active power: 3 dispays, 3-digit or dispay, 2 3; S W, W or of 7 digits dispay with foating decima point MW Reactive power: dispay, 3-digit S, with capacitive or inductive indication; dispay with foating decima point var, var or Mvar Apparent power: 3 dispays, 3-digit or dispay, 3-digit p. f. : 3 dispays, 3-digit or dispay, 3-digit 2 3; S dispay with foating decima point 2 3; S, dispay with foating decima point VA, VA or MVA Transformer primary current ony if set A Transformer secondary current ony if set A or 5 Dispay period /s 2 Storage of setting EEPROM Measuring accuracy Votage % 2 ± digit Current % 2 ± digit Power output % 2 ± digit p. f. % ± digit Frequency % ± digit 0/2 Siemens ET B T 2005

13 Technica specifications Seection and ordering data Measuring Devices 7T 30 mutimeters Data in compiance with DI 4375-, DI and E 600-7T 300 7T 30 7T 302 Safety acc. to E 600- Degree of poution 2 Overvotage category II Operationa votage V 600 Cearances mm 3.0 Creepage distances in device mm 4.3 on printed boards (not instaed) mm 3.0 Test surge votage.2/50 µs V 4 Test votage 50 Hz, min V 2.2 Terminas Main current paths ± screw (Pozidrive) 2 Suppy terminas bade for sotted screw mm mm Conductor cross-sections main current paths rigid, max. mm 2 25 or or 2 4 rigid, min. mm 2.5 Conductor cross-sections for suppy terminas rigid, max. mm or 2.5 fexibe with seeve, min. mm Environmenta conditions Temperature C Reative humidity % ˆ 80 Vibrations sine ampitude at 50 Hz mm 0.25 Protection cass acc. to E 600- II Degree of protection acc. to E IP20 front pane, 96 mm 96 mm IP54 7T 300 7T 302 Mutimeters U c I e U e MW Order o. Weight item PS*/ P. unit V AC A AC V AC g Items for the dispay of 23 eectrica vaues, of which 5 vaues can be continuousy dispayed. for 3-phase, 3/4-wire connection for direct connection x 230/ T for transformer connection of 0 to 5000 A, adjustabe in 5 A increments secondary current, optionay A or 5 A 230 / or /5 3 x 230/ T for front-pane mounting 96 mm 96 mm for transformer connection of 0 to 5000 A, adjustabe in 5 A increments secondary current, optionay A or 5 A 230 / or /5 3 x 230/400 7T * You can order this quantity or a mutipe thereof. Siemens ET B T /3

14 Measuring Devices 7T 30 mutimeters Dimensiona drawings 7T 300 7T I2_333a 2 I2 3 I3 2 3 I2_334a T 302!!! ' % & ' #! ' % # ' # $ = 0/4 Siemens ET B T 2005

15 Schematics Instructions for the connection of transformer counters In the case of cross-section reduction, a short-circuit resistant cabe is required for the power suppy of terminas 2, 5 and 8, depending on the fusing for phases, 2, 3. A fuse of 6 A is recommended for ine protection. Current transformers must not be operated with open terminas as dangerousy high votages can occur, which may resut in persona injuries and property damages. It may aso ead to a therma overoad of the transformers. 63 A 2 63 A 3 63 A 63 A 2 63 A 3 63 A 400 V AC 63 A 230 V AC 230 V AC 230 / 400 V AC 2 3 7T Direct connection 63 A, 4-wire circuit Direct connection 63 A, 3-wire circuit Direct connection 63 A, singe-phase I2_424 6 A 6 A 6 A A 6 A 6 A A 230 V AC 2 3 Measuring Devices 7T 30 7T / 400 V AC Current transformer connection 4-wire circuit 400 V AC Current transformer connection 3-wire circuit 230 V AC Current transformer connection singe-phase 7T 30 mutimeters I2_ Siemens ET B T /5

16 Measuring Devices 7T 3 muticounters Overview A required measuring vaues of an instaation ceary visibe at a gance Innovative matrix seection of assignment and seection of measurement data of the dispay registers For direct connection 63 A or for transformer /A or /5A For transformer primary current of 0 to 5000 A. Input is in 5 A increments Size, mm high, attractive green 7-segment dispay for measured vaues Ceary recognizabe orange text dispay of units assigned to the dispays where the measured vaue appears Dispay of measured vaues on 4 three-fod 7-segment dispays and a 7-fod 7-segment dispay Seection of dispay for active, reactive and apparent energy vaue, 3 or 7-digit Detection of connection errors (phase transposition) Accuracy cass 2 acc. to IEC , -23 Version with A and MS user interface Versions with PROFIBUS DP V interface Appication Extremey compact mutifunction dispay for direct or transformer connection in a three-phase networ with star-deta measurement for the dispay of up to 35 different eectrica measured vaues in a switchgear, incoming or outgoing feeders. A specia feature is the anaysis of the different oads on the phases. Phase dispacement, unsymetrica or unbaanced oads can cause partia overoads. In this case, the muticounter offers a range of different options to combine measured vaues and assess them. You wi find information on A operation and the MS Exce user interface under "A Server". Function Votage measurement The muticounter measures the deta votages against 2; 2 against 3 and 3 against or the star votages, 2, 3 against. Readout data Of the foowing 35 options, you can continuousy dispay 5 indicated vaues. umber Measured vaue Dispay Unit Assignment Active power D W 2 Votage D V 3 Current D A 4 Apparent power D VA 5 p. f. D p. f. 6 Votage D V 2 7 Active power D2 W 2 8 Votage D2 V 2 9 Current D2 A 2 0 Apparent power D2 VA 2 p. f. D2 p. f. 2 2 Votage D2 V Active power D3 W 3 4 Votage D3 V 3 5 Current D3 A 3 6 Apparent power D3 VA 3 7 p. f. D3 p. f. 3 8 Votage D3 V 3 9 Temperature D6 C 20 Current, -conductor D6 A S 2 Active power D4 W S 22 Reactive power D5 var S 23 Apparent power D5 VA S 24 Frequency D6 Hz S 25 p. f. D, D2, D3, p. f. S D6 26 Active energy rate D4 Wh S 27 Active energy rate 2 D4 Wh S 28 Active energy rate D4 Wh S 29 Active energy rate 2 D4 Wh S 30 Reactive energy rate D5 varh S, ind. 3 Reactive energy rate 2 D5 varh S, ind. 32 Reactive energy rate D5 varh S, cap. 33 Reactive energy rate 2 D5 varh S, cap. 34 Apparent energy rate D5 VAh S 35 Apparent energy rate 2 D5 VAh S 2 set vaues are aso indicated 36 Transformer setting D4 CT/A / or /5 37 Transformer setting D5 CT/A /6 Siemens ET B T 2005

17 Function S symbo for the 3-phase system This indicates that a physica units shown under this symbo are aways 3-phase.!!! & " =!! Dispay The muticounters have a covered brighty it ED dispay. The measured vaues are indicated on an -mm high, green, 7-segment ED, the physica units are indicated on an orange ED. Both coors are easier to read than the previousy used red ED. M W V A HZCOS C M CT/A T 2 D D2 D3 M W V A COS M W V A COS M W V A COS V A R h D6 D5 D4 or D5 + D4 M W h O I2_65 Measuring Devices 7T 3 muticounters Matrix seection Conventiona measuring instruments usuay provide votage, current or other simiar vaues for three phases. Muticounters with their matrix seection are consideraby more fexibe and more universa. The 3-fod indications are seected using the rotary and the desired indications confirmed with O. This is foowed by the horizonta seection e.g. W V A VA or p. f., and then the vertica seection, e.g. -2 S. Your matrix seection is set. The vertica data on the dispay can be assigned to any measured vaue in the horizonta data. The etters M and are automaticay assigned according to measuring range, i.e. measured vaue, e.g.: W or MW. Capacitive oads are automaticay indicated by a capacitor, inductive oads by a coi. The foowing diagram shows an exampe of what your matrix seection might oo ie. V V V -2 A 2-3 T 2 W h 3 - O I2_ Siemens ET B T /7

18 Measuring Devices 7T 3 muticounters Technica specifications Data in compiance with E 600-, E , -23, -3 7T 30 7T 3, 7T 32 Suppy Rated contro suppy votage U c V AC 230 Operating range U c Rated frequency Hz 50 Frequency range Hz Rated power dissipation VA ˆ0 Overoad capabiity Votage continuous: phase/phase V 480 second: phase/phase V 800 continuous: phase/ V 276 second: phase/ V 460 7T 340 7T 34, 7T 342 7T 350 7T 35, 7T 352 Current continuous A s A ms A Measuring input Type of connection direct transformer / A or /5 A Votage U e phase/phase V 400 phase/ V 230 Operating range votage phase/phase V phase/ V direct transformer / A or /5 A direct transformer / A or /5 A Current I e A 63 or 5 63 or 5 63 or 5 Operating range current A Transformer current primary current of the A transformer smaest input step A Frequency Hz 50 Operating range frequency Hz Dispay Connection errors inverted phases Err Votage: 3 dispays, 3-digit deta 2, 2 3, 3 V AC star / 2/ 3/ V AC votage > 480/276 V HHH votage < 87/50 V Current 2 3 neutra conductor A or A ( or 6) transformer conversion ratio for current > 76; (.2 or 6 A) HHH transformer conversion ratio for current <0. A; 0.0 A x transformer conversion ratio Frequency: dispay, 3-digit S Hz Active power: 3 dispays, 3-digit 2 3, dispay with foating decima point W, W or MW Active power: dispay, 3-digit, 3 of 7 digits + dispay import or export S dispay with foating decima point Reactive power: dispay, S 3 of 7 digits + capacitive or inductive dispay with foating decima indication point Apparent power: 3 dispays, 3-digit Apparent power: 5 dispays, 3-digit, adjustabe Active energy: dispay, 7-digit + dispay import or export, + dispay tariff or 2 Reactive energy: indicator, 7-digit + capacitive or inductive indication Apparent energy: 5 dispays, 3-digit, adjustabe tariff p. f.: 3 dispays, 3-digit 2 3, dispay with foating decima point S dispay with foating decima point S dispay with foating decima point S dispay with foating decima point S dispay with foating decima point 2 3 (U 0. U e, I ˆ I e ) W, W or MW var, var or Mvar VA, VA or MVA VA, VA or MVA Wh, Wh or MWh varh, varh or Mvarh VAh, VAh or MVAh or or or p. f.: 5 dispays, 3-digit, adjustabe S, (U 0. U e, I ˆ I e ) ( or 6) transformer conversion ratio ( or 6) transformer conversion ratio 0/8 Siemens ET B T 2005

19 Technica specifications Data in compiance with E 600-, E , -23, -3 7T 30 7T 3, 7T 32 Dispay (contd.) Measuring Devices 7T 340 7T 34, 7T 342 7T 3 muticounters 7T 350 7T 35, 7T 352 Transformer primary current ony if set A Transformer secondary current ony if set A or 5 or 5 or 5 Temperature C Dispay period /s 2 Storage of setting and energy vaues EEPROM S0 interface acc. to IEC Termina output for direct connection 63 A, adjustabe and automatic Imp/Wh depending on transformer factor, adjustabe and automatic Imp/Wh Puse duration ms 25 Minimum interva between 2 puses ms 25 Required votage V DC Current ma A interface Pug-and-pay technoogy terminas +,, shieding PROFIBUS DP interface RS 485 Transmission rate bit/s Connection 9-Pin Sub-D Measuring accuracy Votage % 2± digit Current % 2± digit Power output % 2± digit Energy % 2± digit p. f. % ± digit Frequency % ± digit Temperature % 3 ± digit Safety acc. to E 600- Degree of poution 2 Overvotage category II Operationa votage V 600 Cearances mm 3.0 Creepage distances in device mm 4.3 on printed boards (not mm 3.0 instaed) Test puse votage.2/50 µs V 4 Test votage 50 Hz, min V 2.2 Terminas Main current paths ± screw (Pozidrive) Suppy and contro terminas bade for sotted screw mm mm Conductor cross-sections main current paths Conductor cross-sections suppy and contro terminas rigid, max. mm 2 25 or 2 6 rigid, min. mm 2.5 rigid, max. mm 2 6 or 2 4 fexibe with seeve, min. mm or or or or 2 6 Environmenta conditions Temperature C Reative humidity % ˆ 80 Vibrations sinus ampitude at 50 Hz mm 0.25 Protection cass acc. to E 600- II Degree of protection acc. to E IP20 front pane, 96 mm 96 mm IP54 IP54 IP54 6 or Siemens ET B T /9

20 Measuring Devices 7T 3 muticounters Seection and ordering data 7T 30 7T 32 Muticounters U c I e U e MW Order o. Weight item PS*/ P. unit V AC A AC V AC g Items for the dispay of 38 eectrica vaues, of which 5 or 6 vaues can be continuousy dispayed for 3-phase, 3/4-wire connection With S0 interface for direct connection / T for transformer connection of A, adjustabe in 5 A increments, secondary current optionay or 5 A 230 / or / / T for transformer connection of A, adjustabe in 5 A increments, secondary current optionay or 5 A for front-pane mounting 96 mm 96 mm 230 / or / /400 7T With A-Interface for direct connection / T for transformer connection of A, adjustabe in 5 A increments, secondary current optionay or 5 A 230 / or / / T for transformer connection of A, adjustabe in 5 A increments, secondary current optionay or 5 A for front-pane mounting 96 mm 96 mm 230 / or / /400 7T With PROFIBUS DP Interface for direct connection / T for transformer connection of A, adjustabe in 5 A increments, secondary current optionay or 5 A 230 / or / / T for transformer connection of A, adjustabe in 5 A increments, secondary current optionay or 5 A for front-pane mounting 96 mm 96 mm 230 / or / /400 7T Dimensiona drawings 7T 3.0 7T I2_333a 2 I2 3 I3 2 3 I2_334a T 3.2 Rear pane! " # $ % & ' ' % & ' #!!! ' % # ' # # " 0/20 Siemens ET B T 2005 * You can order this quantity or a mutipe thereof.

21 Schematics S0 interface The short-circuit resistant optocouper is operated at 5 to 30 V DC. The current must be seected within a range of max. 20 ma. The puse duration is 25 ms. The minimum puse interva is aso 25 ms. Grounding termina The interpoation point grounding terminas required for the transmission technoogy ony serve to shied the transmission cabes and do not have a protective function. 230 V AC 230 V AC V AC 230 V AC 63 A 2 63 A 3 63 A 63 A 2 63 A 3 63 A 63 A Rate V AC 230 / 400 V AC 400 V AC 230 V AC Rate 7T 350 RS PROFIBUS 7T x DC5 30 V T Rate + + Shied 2 x S0-Interface _ A Server Direct connection 63 A, 4-wire circuit Direct connection 63 A, 3-wire circuit Direct connection 63 A, singe-phase I2_426a Measuring Devices 7T 3 muticounters Instructions for the connection of transformer counters In the case of cross-section reduction, a short-circuit resistant cabe is required for the power suppy of terminas 2, 5 and 8, depending on the fusing for phases, 2, 3. A fuse of 6 A is recommended for the ine protection. Current transformers must not be operated with open terminas as dangerousy high votages can occur, which may resut in persona injuries and property damages. It may aso ead to a therma overoad of the transformers. 6 A 6 A 6 A A 6 A 6 A V AC 230 V AC V AC 230 V AC 7T 35 7T 352 RS PROFIBUS 7T 34 7T 342 A Server 230 V AC 230 V AC 2 x DC5 30 V T T 32 Tariff Tariff Tariff 2 x S0-interface 230 / 400 V AC Current transformer connection 4-wire circuit 400 V AC Current transformer connection 3-wire circuit shieding + _ RS 485-PROFIBUS socet I2_ RS PROFIBUS-Socet = 3= +RxTx 4= RTS 5= 6= DC +5 V 8= -RxTx 6 A 230 V AC I2_427 Current transformer connection singe-phase Siemens ET B T /2

22 Measuring Devices 7T 4 E-counters, singe-phase Overview Features Accuracy cass 2 acc. to IEC With drum-type register 4.2 mm Short-circuit resistant puse output Appication E-counters serve the measurement of Wh in singe-phase systems, e.g. in industria pants, offices and apartments in apartment houses Technica specifications Data acc. to E , -3 7T 40 7T 4 Suppy Rated contro suppy votage U c V AC 230 Operating range U c U c Rated frequency Hz 50 Operating range frequency Hz Rated power dissipation P v VA Measuring input Type of connection direct Votage V 230 Operating range votage V Current A 63 Operating range current direct connection A Minimum operating current ma 5 Frequency Hz 50 Operating range frequency intermoduation distortion 3 %; Hz symmetric sinusoid curve Overoad capabiity Votage U e continuous: phase/ V 276 second: phase/ V 300 Current I e continuous A 63 second A 26 Dispay Rate singe doube Active energy drum-type register H W mm mm x (4 x.2) 7-digit with decima x ( ) Measuring accuracy Active energy at 23 C C % 2 Safety Separation of current and votage circuit eectrica Rated insuation votage V 600 Rated impuse withstand votage inputs against ground V 4 for min. at 50 Hz Overvotage category acc. to E III Puse output S0 interface acc. to DI 43864, IEC IR test output ED Imp/Wh 0 terminas, output Imp/Wh 0 Puse duration ms 25 Minimum interva between 2 puses ms 25 Required votage V DC Permissibe current range ma Terminas Main current paths ± screw (Pozidrive) 2 S0 interface/contro terminas bade for sotted screw mm Conductor cross-sections main current paths rigid, max. mm 2 35 rigid, min. mm 2.5 Conductor cross-sections S0 interface/contro terminas Ambient conditions rigid, max. mm fexibe with seeve, min. mm Temperature storage C operation C Reative air humidity storage % ˆ 98 operation % ˆ 80 Minimum vibration ampitude at 50 Hz mm 0.25 Degree of poution acc. to E Degree of protection IP20 0/22 Siemens ET B T 2005

23 Seection and ordering data Measuring Devices 7T 4 E-counters, singe-phase 2 7T 40 Dimensiona drawings 7T 4 7T 40 U c I e U e MW Order o. Weight item V AC A AC V AC g Items E-counters for active energy with drum-type register 4 2 mm, with S0 interface, for singe-phase operation direct connection, singe rate T direct connection, doube rate T PS*/ P. unit # $! # $ " # ' 7! $! $ % & & = $ " " $ " 8 Schematics 7T 40 7T V AC Tariff 7T S0 Interface T 40 Rate switchover If there is a votage of 230 V AC at termina, the rate must be switched to 2. S0 Interface 63 A 230 V AC I2_ * You can order this quantity or a mutipe thereof. Siemens ET B T /23

24 Measuring Devices 7T 5 E-counters, three-phase Overview Features Function Dispay - or 3-phase measurement for 3- or 4-wire connection and center-tap cacuation for 3-wire connection For direct connection 63 A or for transformer /5A Active energy Rate Unit Wh ID Arrow and T For transformer primary current of 0 A to 5000 A. Rate 2 Wh Arrow and T2 Input is in 5 A increments Reactive energy Rate varh Arrow and T 7-fod 7-segment dispay for energy vaues and additiona function indication Rate 2 varh Arrow and T2 Detection of connection errors (phase transposition) Versions with A interface and MS Exce user interface Active power W Utiization and instantaneous vaue Accuracy cass 2 according to IEC 6036 Reactive power var Utiization and PTB test started. instantaneous vaue Phase-sequence 2 3 Fashing triange next Appication indication to eft-hand phase sequence E-counters serve the measurement of Wh in singe and three-phase systems, e.g. in industria pants, offices and apartments in apartment houses. Primary transformer A CT current (current transformer) Versions with A interface with CD are used for consumption anaysis and minimization of operating costs in industria pants and office buidings. For information on A operation and the MS Exce user interface, see "A Server" on page 0/32. A communication 6 measured vaues, active energy rate and rate 2, reactive energy rate and rate 2, active power and reactive power are transmitted. Transformer setting The primary transformer current is set at the device switch. With regard to the transformer setting, the device dispay is internay converted. This setting can be seaed on certification. Wh varh CT 0 T T2 M W var 3 2 T I2_0805 Technica specifications Data in compiance with E 600-, E , -2, -3 7T 500, 7T 502, 7T 50, 7T 52, 7T 520 Suppy Rated contro suppy votage U c V AC 230 Operating range U c Rated frequency Hz 50 Operating range frequency Hz Rated power dissipation P v VA ˆ0 Measuring input 7T 50, 7T 503, 7T 5, 7T 53, 7T 52 Type of connection direct transformer /5 A Votage U e phase/phase V 400 phase/ V 230 Operating range votage phase/phase V phase/ V Current I e A 63 5 Operating range current direct connection A transformer connection Transformer current primary current A smaest input step A 5 Frequency Hz 50 Operating range frequency Hz Overoad capabiity Votage U e continuous: phase/phase V 480 second: phase/phase V 800 continuous: phase/ V 276 second: phase/ V 460 Current I e continuous A seconds A 0 0 ms A /24 Siemens ET B T 2005

25 Technica specifications Data in compiance with E 600-, E , -2, -3 7T 500, 7T 502, 7T 50, 7T 52, 7T 520 Dispay Connection errors discernibe from phase-sequence indication Active energy: dispay, 7-digit Wh dispay import or export (arrow) Reactive energy: dispay, 7-digit varh dispay import or export (arrow) Active power: dispay, 3-digit W or MW dispay import or export (arrow) Reactive power: dispay, 3-digit + dispay import or export (arrow) Instantaneous rate measurement: dispay, -digit for 7T 500, 7T 50, 7T 502, 7T 503 for 7T 50, 7T 5, 7T 52, 7T 53, 7T 520, 7T 52 var or Mvar or 2 Measuring Devices 7T 5 E-counters, three-phase 7T 50, 7T 503, 7T 5, 7T 53, 7T 52 Dispay rate identifier for 7T 50, 7T 5, 7T 52, T or T2 7T 53, 7T 520, 7T 52 Transformer primary current adjustabe in 5 A steps A Dispay period /s 2 Storage of setting and energy vaues EEPROM Measuring accuracy Active or reactive energy % 2 ± digit Active or reactive power % 2 ± digit S0 interface acc. to IEC Termina output for 7T 500 fixed Imp/Wh 0 for 7T 502, 7T 50, 7T 52 Imp/Wh for direct connection 63 A, adjustabe for 7T 50 fixed Imp/Wh for 7T 503, 7T 5, 7T 53 Imp/Wh depending on the transformer factor, adjustabe Puse duration ms 25 Minimum interva between 2 puses ms 25 Required votage V DC Permissibe current range ma A interface ony for 7T 520, 7T 52 Pug-and-pay technoogy Terminas +,, shieding Safety acc. to E 600- Degree of poution 2 Overvotage category II Operationa votage V 600 Cearances mm 3.0 Creepage distances in device mm 4.3 on printed boards (not instaed) mm 3.0 Test puse votage.2/50 µs V 4 Test votage 50 Hz, min V 2.2 Terminas Main current paths ± screw (Pozidrive) 2 Suppy and contro terminas bade for sotted screw mm mm Conductor cross-sections main current paths rigid (max.) mm 2 x 2.5 or 2 x 6 x 6 or 2 x 4 rigid (min.) mm 2 x.5 x 0.95 Conductor cross-sections suppy and contro terminas Ambient conditions rigid (max.) mm 2 x 2.5 or 2 x.5 fexibe with seeve (min.) mm Ambient temperature C Reative humidity storage % ˆ 80 Vibration sine ampitude at 50 Hz mm 0.25 Degree of protection (termina area) IP40 (IP20) Protection cass acc. to E 600- II Siemens ET B T /25

26 Measuring Devices 7T 5 E-counters, three-phase Seection and ordering data U c I e U e MW Order o. Weight item PS*/ P. unit V AC A AC V AC g Items E-counters for active energy with S0 interface and IR interface, for 3-phase, 3/4-wire connection for direct connection, singe rate / T for transformer connection, singe rate 230 transformer / / T for direct connection, doube rate / T for transformer connection, doube rate 230 transformer / / T E-counters for active and reactive energy with S0 interface and IR interface, for 3-phase, 3/4-wire connection for direct connection, singe rate / T for transformer connection, singe rate 230 transformer / / T for direct connection, doube rate / T for transformer connection, doube rate 230 transformer / / T E-counters for active and reactive energy with A interface and IR interface, for 3 phase, 3/4-wire connection for direct connection, doube rate / T for transformer connection, doube rate 230 transformer / / T Dimensiona drawings 7T 500, 7T 502, 7T 50, 7T 52, 7T T 50, 7T 503, 7T 5, 7T 53, 7T I2_ I2_ Schematics Grounding termina The grounding terminas required for the transmission technoogy for 7T 520 and 7T 52 versions ony serve to shied the transmission cabes and do not have a protective function. Instructions for the connection of transformer counters In the case of cross-section reduction, a short-circuit resistant cabe is required for the power suppy of terminas, 2 and 3 depending on the fusing for phases, 2 and 3. A fuse of 6 A is recommended for the ine protection. Current transformers must not be operated with open terminas since dangerous high votages might occur which may resut in persona injuries and property damages. In addition to this, the transformers are exposed to therma overoad. Rate switchover If there is a votage of 230 V AC at terminas 4 and 5, the rate is switched to 2. 0/26 Siemens ET B T 2005 * You can order this quantity or a mutipe thereof.

27 230 V AC 230 V 63 A 2 63 A 3 63 A 63 A 2 63 A 3 63 A 63 A T V AC 230 V AC 2 x DC5 30 V T Tariff V AC 230 V AC T T / 400 V AC Tariff 230 V AC 230 V AC 230 V AC 230 V AC Tariff T Shied _ A Server 2 x S0-Interface DC5 30 V S0-Interface 2 x DC5 30 V 2 x S0-Interface DC5 30 V S0-Interface Direct connection 63 A, 4-wire circuit Direct connection 63 A, 3-wire circuit Direct connection 63 A, singe-phase I2_428 6 A 6 A 6 A 2 3 AC 230 / 400 V 6 A 6 A 6 A 2 3 AC 400 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V Measuring Devices T AC 230 V 7T 5 E-counters, three-phase T T AC 230 V Tariff Tariff Tariff + + DC5 30 V + DC5 30 V 2 3 7T A Server 2xDC5 30 V + shieding 2 x S0-interface S0-interface 2 x DC5 30 V T x S0-interface S0-interface Current transformer connection 4-wire circuit Current transformer connection 3-wire circuit + _ A AC 230 V I2_429 Current transformer connection singe-phase Siemens ET B T /27

28 Measuring Devices 7T 6 E-counters, three-phase, instabus X EIB Overview E-counter with CD dispay arge-size 7-digit CD 8 4 mm 2 IR readout interface for mounting the readout measuring head 3 Dispay pushbutton 4 IR test output ED (0 IMP./W) 5 Seaabe Set/Reset pushbutton Readout data for consumption anaysis Manua readout The above data can be caed up and manuay dispayed directy on the E-meter by pressing pushbuttons 5) Set/Reset pushbutton and 3) Dispay pushbutton. The E-counter cacuates the consumption costs when the price per Wh has been entered. The abiity to input the device number faciitates assignment to a number system and cost assignment to one of the various cost centers. Readout software for the IR measuring head The data of the above tabe are read into a PC using the magnetic IR measuring head and stored in an ASCII fie in compiance with IEC 607. This ASCII fie can be further processed in an Exce or Access fie. The product range can run under Windows 95, 98 and Windows T. Readout data on the CD or over IR interface 7T 62 7T 65 Active energy rate /2 Wh x/x Price per Wh, adjustabe rate /2 Cost/ x/x Wh Tota costs rate /2 Tota x/x cost Reactive energy rate /2 varh x/x Apparent energy rate /2 VAh Maximum active power rate /2 W Integration periods, rate /2 min adjustabe Instantaneous active power sum tota W x phase /2/3 W x Instantaneous votage phase /2/3 V Instantaneous imported Wh sum tota A phase /2/3 A Instantaneous current factor FA I x ) Instantaneous reactive power Instantaneous apparent power sum tota var phase /2/3 var sum tota VA phase /2/3 VA Instantaneous p. f. phase /2/3 p.f. Instantaneous frequency Hz Device number, adjustabe o. x x = data are dispayed ) Ony for transformer meters Data transmission instabus X EIB The 7T 62 and 7T 65 counters are intended for the foowing data transmission: Active energy (Wh) rate Active energy (Wh) rate 2 Device number Active power (W) phase Active power (W) phase 2 Active power (W) phase 3 Visuaization software "Recording of consumption data and maximum time anaysis" (avaiabe soon) The software can read out and assign counter readings, and prepare the data for accounting. The system does not differentiate between counters that are read out manuay or in onine operation. A maximum time anaysis can be carried out over severa days on the PC in onine operation. Graphica anayses are aso avaiabe. Energy fow direction Counting is ony carried out in the specified energy fow direction. For meters with transformer connection, the energy fow direction of the transformer (primary and secondary) as we as the correct assignment of the votage and current paths must be taen into account. Benefits PTB-approved Accuracy cass 2 CD Short-circuit resistant puse output With networ anaysis functions and direct cost dispay Appication For the measurement of Wh in singe and three-phase systems, e.g. in industria pants, offices and apartments in apartment houses. The versions with CD dispay are used as networ anaysis devices for consumption anaysis and minimization of operating costs in industria pants and office buidings. 0/28 Siemens ET B T 2005

29 Technica specifications Measuring Devices 7T 6 E-counters, three-phase, instabus X EIB 2 7T 62 7T 65 Suppy Rated contro votage U e V AC 230 Operating range U e Rated frequency Hz 50 Operating range frequency Hz Power consumption per phase VA 0.8 Measuring input Type of connection direct transformer Votage V 400 Operating range votage V Current A 63 5 Operating range current direct connection A transformer connection A Minimum operating current ma 5 Current factor of transformer, input in fu digits FAI Frequency Hz 50 Operating range frequency Intermoduation distortion ˆ3 %; Hz symmetric sine curve Overoad capabiity Votage duration: phase/ V 276 second: phase/ V 460 duration: phase/phase V 480 second: phase/phase V 800 Current duration A 76 6 second A 26 0 Dispay Rate doube CD H x W mm x mm 8 x 4 readout data ) 7-digit with decima points Active/reactive Active energy drum-type register H x W: mm x mm 7-digit with decima Dispay period /s 0.5 Storage of measured vaues WH EEPROM Measuring accuracy at 23 C ± C Active energy acc. to IEC 6036 cass 2 Safety Suppy measuring circuit isoation eectrica Rated insuation votage V 600 Rated impuse withstand votage inputs against ground V 4 for min. at 50 Hz Overvotage category VDE 00 T III Puse output, S0 interface acc. to IEC 6393/ DI IR test output ED Imp/Wh 0 terminas, output Imp/Wh 0 minimum puse duration ms 25 externa votage V DC current ma resistance W instabus X EIB interface Standard EIS 9 Readout data ) Terminas Main current paths ± screw (Pozidrive) 2 Suppy/contro-circuit terminas bade for sotted screw mm 0.4 x 2.5 Conductor cross-sections rigid (max.) mm 2 x 0 main current paths rigid (min.) mm 2 x.5 Conductor cross-sections rigid (max.) mm 2 x 2.5 suppy/contro terminas fexibe with seeve mm 2 x 0.75 ) See tabe on page 0/ Siemens ET B T /29

BETA Measuring Three-Phase Measuring Devices

BETA Measuring Three-Phase Measuring Devices BETA Measuring /2 Product overview /3 7T1 30 mutimeters /8 7T1 31, 7T1 34, 7T1 35 muticounters /16 7T1 39 A coupers /19 7T1 5 E-counters /23 7T1 1 E-counters instabus X /27 7T1 2 current transformers /28

More information

A2000 Multifunctional Power Meter 3-348-980-03 20/2.15

A2000 Multifunctional Power Meter 3-348-980-03 20/2.15 3-348-98-3 2/2.15 Measurement of current, votage, active, reactive and apparent power, power factor, active and reactive energy, harmonic distortion and harmonics 2 additiona measuring inputs (optiona)

More information

Power-D-Box Printed Circuit Board Version for 2216/REF16

Power-D-Box Printed Circuit Board Version for 2216/REF16 Power-D-Box Printed Circuit Board Version for 226/REF6 Description The Power-D-Box based on a is a compact power distribution system, designed as a 9" 2U rack made of auminium profies with anodised front

More information

>9700UPS UNINTERRUPTIBLE P O W E R SUPPLIES

>9700UPS UNINTERRUPTIBLE P O W E R SUPPLIES >9700UPS UNINTERRUPTIBLE P O W E R SUPPLIES Mitsubishi The Leader in UPS Technoogy, Quaity & Reiabiity ONE-LINE DIAGRAM OPERATION MENU Static Transfer Switch Superior Performance, Reiabiity and Safety

More information

>2033DUPS UNINTERRUPTIBLE P O W E R SUPPLIES

>2033DUPS UNINTERRUPTIBLE P O W E R SUPPLIES >2033DUPS UNINTERRUPTIBLE P O W E R SUPPLIES Mitsubishi The Leader in UPS Technoogy, Quaity & Reiabiity 2033D ONE-LINE DIAGRAMS Superior Performance, Reiabiity and Safety Come from Experience. Our Uninterruptibe

More information

Precise assessment of partial discharge in underground MV/HV power cables and terminations

Precise assessment of partial discharge in underground MV/HV power cables and terminations QCM-C-PD-Survey Service Partia discharge monitoring for underground power cabes Precise assessment of partia discharge in underground MV/HV power cabes and terminations Highy accurate periodic PD survey

More information

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7 Energy Meters INDEX 1 Measurement Digital single-phase Energy-meters Direct till 32 A 1 module DIN page 5 Digital single-phase Energy-meters Direct till 45 A 1 module DIN page 6 Digital single-phase Energy-meters

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

ZUP SERIES. Model naming method. Features. Applications. Conformity to RoHS Directive. Product Line up ZUP36-12. Programmable CVCC 200W 800W 19Model

ZUP SERIES. Model naming method. Features. Applications. Conformity to RoHS Directive. Product Line up ZUP36-12. Programmable CVCC 200W 800W 19Model SERIES Programmabe CVCC 200W 800W 19Mode Features 800W Constant Votage/Constant Current uit-in RS232 & RS485 Interface An embedded Microprocessor controer Digita Encoder Knob Software Caibration Last Setting

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

Waterside Control Fan Coil Units

Waterside Control Fan Coil Units Issue A, Devember 2011 Waterside Contro Fan Coi Units Horizonta Chassis Type - EPIC Range EPIC the most energy efficient fan coi unit utiising an ECM motor Company Profie Fan Coi Unit Overview Advanced

More information

Data sheet. June 2000 DKACT.PD.P10.F1.02 520B0370

Data sheet. June 2000 DKACT.PD.P10.F1.02 520B0370 Pressure contros and thermostats types KPI and KP June 2000 DKACT.PD.P10.F1.02 520B0370 Pressure contros and thermostats, types KPI and KP Contents Pressure contros KP 35, KP 36, KPI 35, KPI 36 and KPI

More information

Manifold Technology. ----------------------------------------------------- made in Germany

Manifold Technology. ----------------------------------------------------- made in Germany Manifod Technoogy. ----------------------------------------------------- made in Germany I EVERYTHING UNDER CONTROL. Manifod Technoogy BEULCO heating and cooing manifods made of high-quaity brass ensure

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Features and benefits

Features and benefits Showermate provides a range of high quaity, high performing, pastic shower pumps. Designed to boost the performance of shower and tap outets within a bathroom. The range is suitabe for positive and negative

More information

Enhanced continuous, real-time detection, alarming and analysis of partial discharge events

Enhanced continuous, real-time detection, alarming and analysis of partial discharge events DMS PDMG-RH DMS PDMG-RH Partia discharge monitor for GIS Partia discharge monitor for GIS Enhanced continuous, rea-time detection, aarming and anaysis of partia discharge events Unrivaed PDM feature set

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

solenoid dosing pumps

solenoid dosing pumps teknaevo soenoid dosing pumps innovation > technoogy > future The evoution of soenoid dosing pumps Cever Just Modes, Just PVDF, A functions in one pump modes that cover 0, to /h with an output pressure

More information

Energy Management Power Analyzer Type WM14-96 Basic Version

Energy Management Power Analyzer Type WM14-96 Basic Version Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

Hybrid Interface Solutions for next Generation Wireless Access Infrastructure

Hybrid Interface Solutions for next Generation Wireless Access Infrastructure tec. Connectivity & Networks Voker Sorhage Hybrid Interface Soutions for next Generation Wireess Access Infrastructure Broadband wireess communication wi revoutionize every aspect of peope s ives by enabing

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

SACI ENERGY METERS S.A. DE CONSTRUCCIONES INDUSTRIALES

SACI ENERGY METERS S.A. DE CONSTRUCCIONES INDUSTRIALES S.A. DE COSTRUCCIOES IDUSTRIAES COTETS FOR DI RAI MOUTIG Energy Mete COTADORES EERGY METERS DE EERGÍA SIGE-PHASE, DIRECT IPUT...CT.04-07 COTADORES PARA RAÍ DI THREE-PHASE, DIRECT IPUT...CT.08 RESUME THREE-PHASE,

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC100-240V DC12-24V AC100-240V. Output indicator

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC100-240V DC12-24V AC100-240V. Output indicator SERIES Electronic Preset Counter Instruction Manual Please note that misuse of this device may lead to injury to the user or damage to the device. Please observe all safety precautions and warnings in

More information

INSTRUMENTATION FOR SOUND & VIBRATION MEASUREMENTS

INSTRUMENTATION FOR SOUND & VIBRATION MEASUREMENTS INSTRUMENTATION FOR SOUND & VIBRATION MEASUREMENTS SVAN 979 Sound & Vibration Anayser The most advanced and powerfu singe channe SLM & Vibration Meter ever made Extremey powerfu Type 1 SLM (IEC 61672:2002)

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Creat-Poreen Power Electronics Co., Ltd

Creat-Poreen Power Electronics Co., Ltd (STOCK CODE) 002350 Creat-Poreen Power Eectronics Co., Ltd Address: 4F, Xue Zhi Xuan Mansion, NO.16 Xue Qing Road, Hasidian District, Beijing, 100083 Te: +86 (010) 82755151 Fax: +86 (010) 82755268 Website:

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

BC80 system catalog. Building Technologies

BC80 system catalog. Building Technologies BC80 system cataog. Buiding Technoogies 1 A wide range of appications. BC80 comprises an extensive product portfoio and can be instaed in various buiding types. For instance, it is a perfect soution for:

More information

Light Management Systems: Components.

Light Management Systems: Components. .osram.com/ms Ligt Management Systems: Components. Non-system-specific components for expanding, connecting or instaing igt management products. LMS COMPONENTS Expand, connect and insta it non-systemspecific

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

CHANNEL LETTER LIGHTING

CHANNEL LETTER LIGHTING LIGHTING UNIQUE LIGHTING SOLUTIONS WARNING The retrofit instaation must ony be performed by a icensed eectrician. To prevent death, injury or damage to property this product must be instaed in accordance

More information

NCH Software Bolt PDF Printer

NCH Software Bolt PDF Printer NCH Software Bot PDF Printer This user guide has been created for use with Bot PDF Printer Version 1.xx NCH Software Technica Support If you have difficuties using Bot PDF Printer pease read the appicabe

More information

GWPD 4 Measuring water levels by use of an electric tape

GWPD 4 Measuring water levels by use of an electric tape GWPD 4 Measuring water eves by use of an eectric tape VERSION: 2010.1 PURPOSE: To measure the depth to the water surface beow and-surface datum using the eectric tape method. Materias and Instruments 1.

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Applications. diris_826_a_1_gb_cat

Applications. diris_826_a_1_gb_cat Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Avaya Remote Feature Activation (RFA) User Guide

Avaya Remote Feature Activation (RFA) User Guide Avaya Remote Feature Activation (RFA) User Guide 03-300149 Issue 5.0 September 2007 2007 Avaya Inc. A Rights Reserved. Notice Whie reasonabe efforts were made to ensure that the information in this document

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

The width of single glazing. The warmth of double glazing.

The width of single glazing. The warmth of double glazing. Therma Insuation CI/SfB (31) Ro5 (M5) September 2012 The width of singe gazing. The warmth of doube gazing. Pikington Spacia Revoutionary vacuum gazing. Image courtesy of Lumen Roofight Ltd. Pikington

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

3-Phase Energy meter with serial S-Bus interface

3-Phase Energy meter with serial S-Bus interface Data sheet www.sbc-support.com 3-Phase Energy meter with serial S-Bus interface Energy meters with an integrated S-Bus interface allow direct reading of all relevant data, such as energy (Total and partial),

More information

The Simple Pendulum. by Dr. James E. Parks

The Simple Pendulum. by Dr. James E. Parks by Dr. James E. Parks Department of Physics and Astronomy 401 Niesen Physics Buidin The University of Tennessee Knoxvie, Tennessee 37996-100 Copyriht June, 000 by James Edar Parks* *A rihts are reserved.

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

CHANNEL LETTER LIGHTING

CHANNEL LETTER LIGHTING LIGHTING UNIQUE LIGHTING SOLUTIONS WARNING The retrofit instaation must ony be performed by a icensed eectrician. To prevent death, injury or damage to property this product must be instaed in accordance

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

WINMAG Graphics Management System

WINMAG Graphics Management System SECTION 10: page 1 Section 10: by Honeywe WINMAG Graphics Management System Contents What is WINMAG? WINMAG Text and Graphics WINMAG Text Ony Scenarios Fire/Emergency Management of Fauts & Disabement Historic

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

COMPARISON OF DIFFUSION MODELS IN ASTRONOMICAL OBJECT LOCALIZATION

COMPARISON OF DIFFUSION MODELS IN ASTRONOMICAL OBJECT LOCALIZATION COMPARISON OF DIFFUSION MODELS IN ASTRONOMICAL OBJECT LOCALIZATION Františe Mojžíš Department of Computing and Contro Engineering, ICT Prague, Technicá, 8 Prague frantise.mojzis@vscht.cz Abstract This

More information

ADVANCED ACCOUNTING SOFTWARE FOR GROWING BUSINESSES

ADVANCED ACCOUNTING SOFTWARE FOR GROWING BUSINESSES ADVANCED ACCOUNTING SOFTWARE FOR GROWING BUSINESSES Product Features 1. System 2. Saes Ledger Unimited companies with password protection User security Muti-user system: 1 user comes as standard, up to

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

SABRe B2.1: Design & Development. Supplier Briefing Pack.

SABRe B2.1: Design & Development. Supplier Briefing Pack. SABRe B2.1: Design & Deveopment. Suppier Briefing Pack. 2013 Ros-Royce pc The information in this document is the property of Ros-Royce pc and may not be copied or communicated to a third party, or used

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS LOW-PROFILE SURFACE-MOUNT RELAY RELAYS.55 5.6. FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6.5 mm.56 inch) Tape and reel package is available as standard packing style Surge withstand between

More information

2-Piece Power Connectors

2-Piece Power Connectors Quick Reference Guide THINGS TO CONSIDER WHEN CHOOSING POWER CONNECTORS Appication. Does the appication require a board-to-board, wire-to-board, wire-to-wire, bus bar, card edge or a combination of these

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

1. INTRODUCTION FEATURES 2. PROGRAMMING

1. INTRODUCTION FEATURES 2. PROGRAMMING 1. INTRODUCTION Mono phase compensation systems are not useful in plants where unbalanced loads exist. In such plants compensation has to be done by measuring all 3 phase parameters individually. Devices,

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Mechanical Engineering Drawing Workshop. Sample Drawings. Sample 1. Sample 1. Sample 2. Sample 2 2013/7/19. JIS Drawing Part 1

Mechanical Engineering Drawing Workshop. Sample Drawings. Sample 1. Sample 1. Sample 2. Sample 2 2013/7/19. JIS Drawing Part 1 Mechanica Engineering Drawing Workshop Sampe Drawings JIS Drawing Part Content:.Sampe Drawings 2.Drawing sheets 3. Views and projection methods 4. Line Conventions 5. Scaes 6. Sectiona drawings 7. Detai

More information

DISPLAYING NASDAQ LEVEL II DATA

DISPLAYING NASDAQ LEVEL II DATA 14 NASDAQ LEVEL II windows et you view Leve II data for NAS- DAQ stocks. Figure 14-1 is an exampe of a NASDAQ Leve II window. Figure 14-1. NASDAQ Leve II Window Exampe Information in Leve II windows is

More information

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with SOLAR MICRO INVERTER 260 COMMUNICATI GATEWAY Apparent Power Control (APC) P Q unique micro inverter with REAL & REACTIVE POWER CTROL 2 Micro Inverters unique micro inverter with real & reactive power control

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

Custom Products. Magnetic Components. Vishay Dale. www.vishay.com

Custom Products. Magnetic Components. Vishay Dale. www.vishay.com Magnetic Components SWITCH MODE MAGNETICS AIR CORE INDUCTORS INDUCTIVE PRODUCTS CUSTOM DESIGN AND PRODUCTION has extensive facilities for custom design and production of custom magnetics. Design applications

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational

More information

Gas turbine air intake media

Gas turbine air intake media Gas turbine air intake media Gas turbine air intake fiter media soutions High energy cost and demand wordwide have increased the focus on energy efficiency in many industries and market sectors. Specificay,

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

Nemo 96HD/HD+ MODBUS

Nemo 96HD/HD+ MODBUS 18/12/12 Pagina 1 di 28 MULTIFUNCTION FIRMWARE 2.30 Nemo 96HD/HD+ MODBUS COMMUNICATION PROTOCOL CONTENTS 1.0 ABSTRACT 2.0 DATA MESSAGE DESCRIPTION 2.1 Parameters description 2.2 Data format 2.3 Description

More information

Pipe and Drain Inspection and Cleaning

Pipe and Drain Inspection and Cleaning Pipe and Drain Inspection and Ceaning ROSCOPE 6 Pipe and Drain Inspection Systems 69, 70 ROCAM Camera Sonde Locator 71 R600 Drain Ceaning Machine 72 ROSPI Pus Manua Drain Ceaning Unit 73 Drain Ceaning

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz

Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Current transformers (CT) & Shunts

Current transformers (CT) & Shunts Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar

More information

Eaton Network Card-MS. User s Guide

Eaton Network Card-MS. User s Guide Eaton Network Card-MS User s Guide Cass B EMC Statements FCC Part 15 Cass B This equipment has been tested and found to compy with the imits for a Cass B digita device, pursuant to part 15 of the FCC Rues.

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

BSimplex 4001-9403 and -9404

BSimplex 4001-9403 and -9404 BSimpex 4001-9403 and -9404 Fire Aarm Systems Instaation and Operating Instructions 0 1995 Simpex Time Recorder Co. FA4-21-004 (574-047) A specifications and other information shown were current as of

More information

SINEAX U553 Transducer for AC Voltage

SINEAX U553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information