ABB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014

Size: px
Start display at page:

Download "ABB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014"

Transcription

1 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

2

3 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014 BB i-bus KNX Selection Tables B MDRC = Modular DIN-rail Component, SM = Surface Mounting, FM = Flush Mounting, LF = Light Fitting, *PG = Price Group, **MW = Module Width 18 mm, HVC = Heating/Ventilation/ir-Conditioning BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C0202 1

4 2 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

5 BB i-bus KNX Contents 1 Power Supplies 6 2 System Components and Interfaces 10 3 Connection and Wiring 13 4 Room utomation 14 5 Inputs 21 6 Outputs 26 7 Shutters and Sun Protection 31 8 Illumination and Light Sensors 36 9 Heating and Cooling Control, Logic and Time Visualisation, Display and Signalling Operation Electricity Meters Security and Surveillance WaveLINE Wireless Control Newron Integration in Building Management Systems 167 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C0202 3

6 BB i-bus KNX-Overview 230 V Mains Supply Power Supply IP-Router Programming (ETS), nalysis (i-bus Tool), Visualization ETHERNET KNXnet/IP, OPC, Remote access, Interfacing to other systems Measure energy consumption - Energy Meter with Meter Interface Module - Energy Module Switch energy with and without current detection - Switch ctuator Switch energy with energy measurement - Energy ctuator Switch, dim and control light - Universal Dim ctuator - Switch/Dim ctuator 1 10 V - Light Controller Digital lighting control by the use of DLI - DLI Gateway - DLI Light Controller - DLI Gateway with Emergency Lighting Control Drive control of rolling shutters, blinds and ventilation fl aps with and without automatic travelling time detection - Blind/Roller Shutter ctuator - SMI Blind-/Roller Shutter ctuator Heating/cooling by the control of valves - Electronic Switch ctuator - Valve Drive ctuator - Electromotor Valve Drive Ventilation/climatization - Blower/Fan Coil ctuator - Fan Coil ctuator and Controller Room Controller with functional modules ctuator functions 4 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

7 Power Supply Line Coupler KNX-Main Line/TP - 64 devices/line - 15 lines/area with superordinated main line - max. 15 areas with superordinated area line Line Binary Input Detect and evaluate switching commands - nalogue Input Capture, evaluate and monitor physical values - Weather Station and Weather Sensor Evaluate and monitor meteorological data (wind, temperature, rain, etc.) Display operating conditions and control functions - Presence Detector - Movement Sensor - Light Sensor Detect presence and movement Measure brightness level Lighting Control - Logic Module - pplication Unit Logic - pplication Unit Time - Time Switch B 1 y B & y Perform logical operations and trigger timer-controlled functions - Room Thermostat - ir Quality Sensor Capture, evaluate, monitor and control room conditions, temperature, air quality, etc. - Security Terminal - Security Module - KNX Security Panel - Fault Monitoring Unit - Monitoring Unit - Data Logging Unit 12 V Security System Monitor operating conditions, signal technical faults, recognize hazards and trigger alarms Room Master devices with different comwinations of inputs and outputs and internal logical interconnection Solutions for rooms with sensor and actuator functions Sensor functions BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C0202 5

8 BB i-bus KNX Power Supplies 1 SV/S Power Supply, 160 m, MDRC NEW KNX power supplies generate and monitor the KNX system voltage (SELV). The bus line is decoupled from the power supply by an integrated choke. The voltage output is short-circuit and overload protected. The two-color LED indicates device output status. With two-coloured status indicator and wide range input from V C, 50/60 Hz. unit 4 SV/S CDG110144R SV/S Power Supply, 320 m, MDRC NEW KNX power supplies generate and monitor the KNX system voltage (SELV). The bus line is decoupled from the power supply by an integrated choke. The voltage output is short-circuit and overload protected. The two-color LED indicates device output status. With two-coloured status indicator and wide range input from V C, 50/60 Hz. unit 4 SV/S CDG110166R SV/S Power Supply, 640 m, MDRC NEW KNX power supplies generate and monitor the KNX system voltage (SELV). The bus line is decoupled from the power supply by an integrated choke. The voltage output is short-circuit and overload protected. The two-color LED indicates device output status. Device type SV/S has an additional 30 V DC short-circuit and overload protected voltage output that can be used to power an additional bus line (in combination with a separate choke). With two-coloured status indicator and wide range input from V C, 50/60 Hz. unit 4 SV/S CDG110167R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

9 BB i-bus KNX Power Supplies SV/S Power Supply with diagnostics, 320 m, MDRC NEW Compact Power Supply with integrated choke. Quick diagnostics by LED display and ETS communication objects. nalysis of the operating state and the bus line possible by means of BB i-bus tool. unit 4 SV/S CDG110145R SV/S Power Supply with diagnostics, 640 m, MDRC NEW Compact Power Supply with integrated choke. Quick diagnostics by LED display and ETS communication objects. nalysis of the operating state and the bus line possible by means of BB i-bus tool. dditional voltage output to supply an additional line in conjunction with an additional choke. unit 4 SV/S CDG110146R Uninterruptible Power Supply, 640 m, MDRC Power supply with integrated choke for supplying a bus line from an uninterrupted supply. Quick diagnostics via LED display for operational readiness, fault and battery level as well as a floating contact for a fault signal indication. The accumulator module or up to 2 rechargeable batteries can be charged in normal operation by the voltage supply. The bus voltage is provided by the batteries in the event of a mains failure. SU/S unit 8 SU/S GHQ R Battery Module, 12 V DC, MDRC With lead-gel battery for use in uninterruptible power supply SU/S and for maintaining the bus voltage during a mains failure for 10 minutes (at full load). Connection is made via 4-core standard cable. M/S 12.1 unit 8 M/S 12.1 GHQ R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C0202 7

10 BB i-bus KNX Power Supplies 1 KS/K 4.1 KS/K 2.1 Cable Sets For connection of sealed lead gel batteries SK7, SK12 and SK17 to the uninterruptible KNX power supply SU/S or the uninterruptible power supply NTU/S If only one battery is connected, the basic cable set KS/K 4.1 with integrated temperature sensor is to be used. In case two batteries are connected in parallel, the basic cable set KS/K 4.1 is to be used for the first battery and the extension cable set KS/K 2.1 is to used for the second battery. It is not permitted to connect more than two batteries in parallel. unit Basic KS/K 4.1 GHQ R Extension KS/K 2.1 GHQ R SK17, SK12, SK7 Sealed Lead cid Batteries, 12 V DC For maintaining the bus voltage during a mains failure. For connection to the uninterruptible power supply SU/S or the uninterruptible power supply NTU/S maximum of two batteries of the same type can be connected in parallel. For connection, the cable sets KS/K 4.1 and KS/K 2.1 are to be used. unit 7.2 h SK7 GHV V h SK12 GHV V h SK17 GHV V DR/S 4.1 Choke, MDRC The device can be used together with the SV/S to supply a second line. Integrated reset button for resetting the bus devices. Connection via connection terminals. unit 2 DR/S 4.1 2CDG110029R NTI/Z Commissioning Power Supply, 28 V DC, 30 m For temporary power supply of KNX devices during commissioning. The Euroconnector and plug-in terminal provide faster connection and supply of devices with manual operation (e.g. FC/S). unit NTI/Z CDG110096R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

11 BB i-bus KNX Power Supplies NT/S Power Supply Units, MDRC The supply units that can be used universally as the auxiliary power supply in KNX installations or other SELV applications. The devices supply a regulated output voltage of 12 V DC or 24 V DC with a maximum output current of 1.6 or 0.8. The units are protected against overload, the output being able to sustain a continuous short circuit. LED indication of the status of the supply and output voltage. unit 12 V DC, NT/S GHQ R V DC, NT/S GHQ R NTU/S Uninterruptible Power Supply, 640 m, MDRC Power supply with integrated choke for supplying a bus line from an uninterrupted supply. Quick diagnostics via LED display for operational readiness, fault and battery level as well as a floating contact for a fault signal indication. The accumulator module or up to 2 rechargeable batteries can be charged in normal operation by the voltage supply. The bus voltage is provided by the batteries in the event of a mains failure. unit 12 V DC, 2 8 NTU/S CDG110070R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C0202 9

12 BB i-bus KNX System Components and Interfaces 2 LK/S 4.2 Line Coupler, MDRC The line coupler is used in larger installations to connect KNX lines or areas. The lines or areas are galvanically isolated from one another. Telegrams can be filtered to simultaneously reduce the telegram traffic between lines or areas. With ETS 4 (V4.1.2 and higher) the complete group address range of the main groups can be filtered. Within a line, the LK/S 4.2 can also be used as a line amplifier (repeater). unit 2 LK/S 4.2 2CDG110171R IPR/S 2.1 IP Router, MDRC The IP Router is the interface between the KNX installations and the IP networks. It can be used as a quick line or area coupler or utilise the local network (LN) for quick exchange of telegrams between the lines/areas. With ETS 3.0, KNX devices can be programmed via LN. The device uses the KNXnet/IP protocol of the KNX ssociation (Routing and Tunnelling). The IP address can be fixed or received from a DHCP server. The device requires a 10 to 30 V DC power supply. unit 2 IPR/S 2.1 2CDG110061R IPS/S 2.1 IP Interface, MDRC Interface between the KNX installations and IP networks for programming KNX devices in conjunction with ETS 3.0 or for transferring telegrams to/from the LN (e.g. for visualisation). The device uses the EIBnet/IP protocol of the KNX ssociation (Tunnelling). The IP address can be fixed or received from a DHCP server. The device requires a 10 to 30 V DC power supply. unit 2 IPS/S 2.1 2CDG110098R ISM/S 5.1 IP Switch, Master, MDRC IP Switch Master for MDRC installation. For networking of up to 5 end devices. Can be extended to 10 end devices by side connection of the IP Switch Slave (ISS/S). One of the ports is a Gigabit Ethernet enabled and can serve as an uplink port. unit 6 ISM/S 5.1 2CDG120034R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

13 BB i-bus KNX System Components and Interfaces ISS/S 5.1 IP Switch, Slave, MDRC IP Switch Slave for MDRC installation. For networking of up to 5 end devices. Can be side connected to the IP Switch Master (ISM/S), accordingly can be extended to 10 end devices. The slave is only functional together with the master. unit 6 ISS/S 5.1 2CDG120035R / Patch Panel PoE 3gang, MDRC For the setup of small and medium-sized network installations. For the power supply of up to 3 terminal devices such as IP telephone or IP webcams direct via the network cable. For all PoE applications of class 0 to 3, such as IP telephone, IP cameras, WLN access points or PoE switches. External power supply via 8186/04 necessary. unit 8186/ / Power supply PoE 48 V, DR For the setup of small and medium-sized network installations. For the power supply of patch panel PoE 3gang 8186/03. Nominal voltage: V. unit 8186/ IPM/S 1.1 IP Patch Module, MDRC The IP Patch Module consists of an RJ-45 module and a mounting adapter for rail mounting. unit 1 IPM/S 1.1 2CDG120036R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

14 BB i-bus KNX System Components and Interfaces 2 USB/S 1.1 USB Interface, MDRC For connection of a PC via the USB port for programming and diagnostics from ETS3. Display of connection and data transfer via LED. unit 2 USB/S 1.1 2CDG110008R LL/S 1.1 Optical Fibre Interface, MDRC The device is used to couple two sections of an bus line using an optical fibre link. Ideal for bridging longer distances or to avoid having to implement lightning and overvoltage protection when laying cables between buildings. Two devices are needed to complete a transmission link. unit 4 LL/S 1.1 GHQ R EG/ KNX/EnOcean Gateway, SM NEW To connect and integrate EnOcean devices into KNX networks with bidirectional data exchange. The KNX/EnOcean Gateway sends its data within the MHz frequency band which is only approved for EnOcean in the European Union incl. Switzerland, Turkey & Norway. Please ensure that the product is suitable for application in the intended country of final installation and use before purchase. Dimensions: (L x W x H) 100 x 70 x 28. unit EG/ CDG120047R KNX TP/RF WaveLine Gateway, SM Media converter with internal antenna for conversion of KNX RF WaveLine radio signals to KNX twisted pair networks with 24 channels. For the evaluation and transfer of up to 24 channels each with 4 sub-channels as transmitter or receiver. Simple operation due to programming button and display on the device. Is surface-mounted. The KNX/WaveLine Gateway is powered via KNX and does not require an additional power supply. unit WaveLINE components are available in chapter WaveLINE wireless control. 12 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

15 BB i-bus KNX Connection and Wiring DSM/S 1.1 Diagnosis and Protection Module, MDRC Enables quick diagnosis of the bus state and indicates telegram traffic via an LED. bus fault is indicated by contacts. The DSM also suppresses transient overvoltages and interference voltage spikes on the bus and thus protects the connected devices. unit 2 DSM/S 1.1 2CDG110060R VB/K Wiring Jumpers For the interconnection of devices with a bus connection terminal. The vertical and horizontal versions are matched to typical wiring applications. unit horizontal, 100 mm 2 VB/K GHQ R horizontal, 200 mm 4 VB/K GHQ R vertical, 270 mm VB/K GHQ R vertical, 360 mm VB/K GHQ R PS 1/4/6-KNX PS-END 1-S Busbars For interconnection of the phase supply to multiple input terminals on devices such as SD/S, S/S, 6197,. They reduce the wiring effort and ensure safe interconnection. The PS 1/4/6 is prefabricated and can be used immediately. The PS 1/60/6 is cut to the desired length and sealed with end caps. unit 1 phase, 4 contacts PS 1/4/6-KNX 2CDG924003R phase, 60 contacts PS 1/60/6-KNX 2CDG924004R End cap PS-END 1-S 2CDL000001R US/E 1 Connection Terminals For connecting bus devices as well as for looping through or branching the bus cable. vailable in black/red for use as bus connecting terminal, in blue as bus connecting terminal with surge protector and in white/yellow for use as a connecting terminal. unit black/red BUSKLEMME GHQ R white/yellow KLEMME GHQ R with surge protector US/E 1 GHQ R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

16 BB i-bus KNX Room utomation Easy Planning through Flexibility 4 RC/ The fundamental principle: One device per room single Room Controller controls all the room functions. This one device per room principle economically and flexibly provides KNX functionality: With 4 or 8 modules, which are simply inserted into the basis device, all loads in this room (lights, blinds, heating, etc.) can be controlled. KNX RC/ Economic security from the outset The installation concept of the Room Controller, particularly the simple plug-in module concept, provides security and reliability. When planning the infrastructure of a building: It can be undertaken without exact knowledge of the subsequent user demands. During commissioning: When user demands have been determined, they are implemented by simple insertion of modules. In operation in a building: Modifications to the room utilisation are easy to implement. The changes to the cable routing are limited to the room concerned. Improved fire protection included The significant reduction in the wiring also considerably reduces the fire load and thus improves safety for persons and assets. Save on energy and not on comfort Each room is used differently. The different module assignments of the Room Controller can be configured accordingly. Just three examples of special building functions that can be implemented with the device. In the lighting sector Constant lighting control is not the only conceivable solution. high level of comfort can be assured by the control of different light scenes. Blinds and roller shutters Not only do they provide pleasant shading, they also assist in responsible use of energy. Intelligent facade controls move the blinds to suit the position of the sun. Heating/Ventilation/ir conditioning The control of electrothermal valves on radiators is no problem for the electronic switch actuator module of the Room Controller. The ventilation can also be integrated into this automatic control. 14 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

17 BB i-bus KNX Room utomation Overview of switching performance S/M S/M SD/M LR/M UD/M ES/M ES/M Outputs Load circuits 2 relay outputs 2 relay outputs, floating 2 relay outputs 1 relay output Semiconductor output, dimmed via phase interval or phase control U n rated voltage 250/440 V C 250/440 V C 250/440 V C 250/440 V C I n rated current 6 X 16 6 X 6 X Control outputs 2 x 1 10 V DC 1 x 1 10 V DC (passive) (passive) Max. control current 30 m 30 m Max. output power 300 V at 230 V C 150 V at 127 V C Min. output power: 2 V Max. cable length 100 m 100 m Switching current per output C3 operation (cos ϕ = 0.45) EN / 230 V 8 / 230 V 6 / 230 V 6 / 230 V C1 operation (cos ϕ = 0.45) EN / 230 V 16 / 230 V 6 / 230 V 6 / 230 V Fluorescent lighting load X to EN / 250 V (70 μf) 16 / 250 V (70 μf) 6 / 250 V (70 μf) 6 / 250 V (70 μf) Minimum switching capacity 100 m / 12 V 100 m / 24 V 100 m / 12 V 100 m / 24 V 100 m / 12 V 100 m / 24 V 100 m / 12 V 100 m / 24 V DC current switching capacity (resistive load) 6 / 24 V= 16 / 24 V= 6 / 24 V= 6 / 24 V= Lamp loads at 230 V C Incandescent lamp load 1380 W 2300 W 1380 W 1380 W Fluorescent lamps T5 / T8 Uncompensated 1380 W 2300 W 1380 W 1380 W Parallel compensated 1380 W 1500 W 1380 W 1380 W DUO connection 1380 W 1500 W 1380 W 1380 W Low-volt halogen lamps Inductive transformer 1200 W 1200 W 1200 W 1200 W Electronic transformer 1380 W 1500 W 1380 W 1380 W Halogen lamp 230 V 1380 W 2300 W 1380 W 1380 W Dulux lamp Uncompensated 1100 W 1100 W 1100 W 1100 W Parallel compensated 1100 W 1100 W 1100 W 1100 W Mercury-vapour lamp Uncompensated 1380 W 2000 W 1380 W 1380 W Parallel compensated 1380 W 2000 W 1380 W 1380 W Switching capacity Max. peak inrush-current Ip (150 μs) Max. peak inrush-current Ip (250 μs) Max. peak inrush-current Ip (600 μs) Number of electronic ballasts (T5/T8, single element) 18 W (BB EVG 1x18 CF) W (BB EVG-T5 1x24 CY) W (BB EVG 1x36 CF) W (BB EVG 1x58 CF) W (Helvar EL 1x80 SC) semiconductor outputs for resistive loads, inrush current: max. 1, continuous current: max. 700 m 4 Further technical specifications can be found in the corresponding product manuals at BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

18 BB i-bus KNX Room utomation Room Controller Basis Devices 4 Room Controller The Room Controller controls all the functions in the room as a central device. Due to its modular design, it can be adapted flexibly to the required functionality. On-site installation enables short assembly and commissioning times. structured cable entry creates clarity and flexibility for changes in function both during planning and operation. Configuration example RC/ 8.1 Special features Height 50 mm: optimised for underfloor installation or suspended ceilings Room Controller counts as just one bus device Robust housing, IP 54 degree of protection Manual operation for immediate testing even without bus voltage Comprehensive software functionality RC/ 4.2 Room Controller, Basis Device for 4 Modules, SM It accommodates up to 4 plug-in modules and controls their functions. The RC/ 4.2 communicates as a bus device. ny module type can be plugged into each module slot. manual control for module function test is integrated. Dimensions: (H x W x D) 200 x 275 x 50. unit RC/ 4.2 2CDG110104R RC/ 8.2 Room Controller, Basis Device for 8 Modules, SM It accommodates up to 8 plug-in modules and controls their functions. ny module type can be plugged into each module slot. The inserted module is automatically detected. The manual operation facility enables an immediate function test even when bus voltage is not applied. Dimensions: (H x W x D) 270 x 316 x 50. unit RC/ 8.2 2CDG110106R Please note: With the new DLI Light Controller 4-fold, SM DLR/ the DLI Lighting Control can be integrated in a decentralised KNX installation too! Further information about DLR/ in chapter CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

19 BB i-bus KNX Room utomation Room Controller Function Modules BE/M Binary Input Modules, 4-fold Each of the modules provides 4 inputs. There are 3 module types available for the connection of 115/230 V, 12/24 V (C or DC) or floating contacts to cover all demands. unit 230 V BE/M CDG110005R /24 V BE/M CDG110006R Contact scanning BE/M CDG110007R S/M Switch ctuator Module, 2-fold, 6 For switching loads up to 16 at a maximum continuous current of 6. unit S/M CDG110002R S/M Switch ctuator Module, 2-fold, 16, floating contacts For switching two loads up to 16. The switched voltage is independent of the basic device and is connected directly to the module. unit S/M CDG110100R J/M Shutter ctuator Modules, 2-fold For controlling two independent blind or shutter drives. There are two module types available for 115/230 V C or 24 V DC drives. unit 230 V C J/M CDG110003R V DC J/M CDG110004R SD/M Switch/Dim ctuator Module, 2-fold, 6 X It enables the switching and dimming of two groups of luminaries in conjunction with electronic ballasts via a 1 10 V control voltage. Enhanced swiching capacity. (Replaces the SD/M 2.6.1). unit SD/M CDG110107R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

20 BB i-bus KNX Room utomation Room Controller Function Modules 4 LR/M Light Controller Module, 1-fold, 6 X Enables switching and dimming of a lighting group via V control voltage. The device can be used for constant lighting control in conjunction with Light Sensor LF/U 2.1. (Replaces the LR/M 1.6.1). unit LR/M CDG110108R UD/M Universal Dim ctuator Module, 1-fold, 300 V For dimming incandescent lamps, 230 V or low-voltage halogen lamps up to 300 W/V. The automatic load detection detects the connected load and optimises the control. The minimum load is just 2 W. unit UD/M CDG110012R ES/M Electronic Switch ctuator Module, 2-fold With 2 overload-proof outputs for noiseless control of heating systems and chilled ceilings via thermoelectric valve drives. Two module types for voltages from 115/230 V or 24 V (C or DC) are available. unit 115/230 V ES/M CDG110013R V ES/M CDG110014R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

21 BB i-bus KNX Room utomation Room Master RM/S 1.1 RM/S 2.1 RM/S 3.1 RM/S 4.1 Room Master The Room Master is a KNX device with a combination of inputs and outputs. The quantities, technical data and the functions of these inputs and outputs are compiled, so that overall control of all the functions in rooms of a live-in character or apartments, are implemented via a device. Typical areas of application of the Room Master are hotel rooms, hospital rooms as well as apartments in institutions for residential care or in student residential homes. The Room Master with its compact design covers all the basic requirements for Lighting control Heating/ir conditioning Shading control (shutters, blinds or curtains - with the RM/S 2.1) Control of further loads via switched electrical sockets Function extensions are possible at any time, e.g. devices for dimming via BB i-bus KNX. Overview of the inputs and outputs RM/S 1.1 RM/S 2.1 RM/S 3.1 RM/S 4.1 pplication possibilities Binary inputs via contact scanning For connection of switches or push-buttons (light on/off, shutter up/down,etc.) or sensors (window contacts, door contacts, water sensors, condensation water sensors, hotel acrd readers, etc.) Outputs 20 (16 X) Bathroom fan, switching of electrical sockets Outputs 16 (10 X) 2 1 uxiliary electrical heating of fan-coil units (at RM/S 1.1 and 2.1), lighting Outputs speed fan control (at RM/S 1.1 and 2.1), lighting Outputs Valve control (heating, cooling) electronic Outputs 6 changeover contact 1 4 (configurable as switch outputs too) Blind or roller blind control 4 RM/S 1.1 and RM/S 2.1 are preprogrammed ex factory RM/S 3.1 and RM/S 4.1 are programmable with predefined and tested example projects (ETS 4) for different fields of application (office, schools, hotel rooms,...) Commissioning of the preprogrammed devices on the construction site without notebook and ETS programming. With the electrical connection all room functions are available. Optional functional extensions via integration into KNX networks with ETS software. Further information about Room Master on unit Inputs, Outputs, Fan Coil 8 RM/S 1.1 2CDG110094R Inputs, Outputs, Blind 12 RM/S 2.1 2CDG110095R Control, Fan Coil Inputs, Outputs, Blind 12 RM/S 3.1 NEW 2CDG110165R Control or Outputs Inputs, Outputs 8 RM/S 4.1 NEW 2CDG110170R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

22 BB i-bus KNX Room utomation Flush-mounted Combined Devices /11 U-500 Flush-mounted combined actuator For controlling blind or awning motors. For connecting thermoelectric actuating drives. With 3 inputs and 2 outputs. first output (O1) allows the control of electrically-operated Venetian blinds, roller shutters, awnings, venting louvers or similar blinds for 230 V C mains voltage. One additional electronic switching output (O2) allows silent control of electrothermal valve drives for heating or cooling systems. The bus can be connected via enclosed terminal block. Rated voltage: 230 V~, +10% / 10%, 50 Hz 60 Hz. Input polling voltage 5V. O1 Rated current 3, cos ϕ 0.8; Output voltage: 250 V~. O2: Rated current: 25 m, cos ϕ 1, Output voltage: 250 V~. unit 6173/11 U /11 U-500 Switch actuator, 16 For switching 230 V~ consumers. Equipped with two extension inputs which depending on parameterization can act directly on the switching output or alternatively as binary inputs on the KNX bus. One Normally open contact, potential free; switching voltage: 230 V C; 50/60 Hz; max. switching current: 16 ; switching capacity: up to W depending on the consumer. Rated voltage: 230 V~, +10% / 10%, 50 Hz 60 Hz. The bus can be connected via enclosed terminal block. unit 6151/11 U /11 U-500 Blind actuator For controlling blind or awning motors. With 3 inputs and 1 change-over output normally open contact, potential-bound. Rated voltage: 230 V~, +10% / 10%, 50 Hz 60 Hz. Input polling voltage: 5 V. Output rated current: 3, cos ϕ 0.8, Output voltage: 250 V~. The bus can be connected via enclosed terminal block. unit 6152/11 U /11 U-500 Heating actuator 1 electronic output (noiseless) For connecting thermoelectric actuating drives. The device possesses three additional input. Rated voltage: 230 V~, +10% / 10%, 50 Hz 60 Hz. Input polling voltage 5 V. OutputRated current: 25 m, cos ϕ 1. Output voltage: 250 V~. The bus can be connected via enclosed terminal block. unit 6164/11 U CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

23 BB i-bus KNX Inputs 5 pplication Operation of KNX systems via conventional push buttons and switches Processing of binary signals (signalling contacts) Benefits Flexible application due to wide-range inputs Reduced stock requirement due to streamlined product range Simplified commissioning using the copy function Product BE/S with 4 inputs for contact scanning and manual operation BE/S with 4 wide-range inputs and manual operation BE/S with 8 inputs for contact scanning and manual operation BE/S with 8 wide-range inputs and manual operation Wide-range inputs and a streamlined range The new BB i-bus KNX Binary Inputs. BB i-bus KNX Binary Inputs serve as an interface for operation of KNX systems via conventional push buttons and switches as well as for processing binary signals (signalling contacts). In contrast to the existing solutions, where the input voltages of 24 V and 230 V required separate devices, the new Binary Inputs now feature widerange inputs, which can process voltage signals ranging from 10 to 230 V C/DC. This offers the installer significantly greater flexibility. In addition to two devices with 4 and 8 wide-range inputs, the new BB i-bus KNX Binary Input product range is rounded off by two devices with 4 and 8 inputs with scanning voltage. On these types, a pulsed scanning voltage is provided for connection of floating contacts from the device. With an identical range of applications, the number of BB i-bus KNX Binary Inputs is now reduced from 6 types to 4. ll Binary Inputs feature a high-quality membrane keypad for comfortable manual operation and display of the device functions. Input states can be simulated at the device, so that the conventional push buttons, switches or floating contacts do not need to be connected for commissioning purposes. The device functions can be easily tested during commissioning in this way. The Binary Inputs are powered via the KNX and do not require an additional power supply. The software functionality of the Binary Inputs has also been extended. It is now possible to send several switching telegrams with just a single push of a button. Especially useful, just as in the case of the Switch ctuators, it is also possible to copy the channels of the device in the ETS. The parameters and group addresses of a channel can be simply transferred to other channels in this way. This simplifies project engineering and helps reduce sources of error. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

24 BB i-bus KNX Inputs 5 Binary Inputs Selection Table BE/S BE/S BE/S BE/S US/U 2.2 US/U 4.2 US/U 12.2 General Voltage range V V Voltage type C/DC C/DC Contact scanning n n n n n Inputs Type of installation MDRC MDRC MDRC MDRC FM FM FM Module width (space unit) Switch sensor Send switch value after any edge n n n n n n n Send switch value after signal length and/or cyclically n n n n n n n Send switch value 1 cyclically n n n n n n n Send switch value 2 n n n n Send switch value 3 n n n n Difference between short and long operation n n n n n n n Dim sensor Start-stop dimming, step-by-step dimming n n n n n n n One-touch dimming n n n n n n n Shutter Sensor Shutter operation via a push button/switch n n n n n n n Shutter operation via two push buttons/switches n n n n n n n Value/Forced operation 1 bit [0/1], 2 bit forced operation n n n n n n n 1/2/4 bytes n n n n n n n Signed n n n n 3 byte, time, weekday n n n n Control scene 8 bit scene n n n n n n n Store scene n n n n n n n Switching sequence Several preset sequences can be set n n n n n n n Link several push buttons in a switching sequence (actuating number) n n n n n n n Multiple operation Telegram for long operation n n n n n n n Multiple operation can be set n n n n n n n Pulse counter djustable data type and threshold values n n n n n n Temporary counter activation n n n n n n Send counter level cyclically n n n n n n Manual operation Energy-saving mode n n n n Enable/release manual operation n n n n Manual operating status n n n n Enable/release manual operation button per input n n n n Input LED can be inverted n n n n Special functions Copying and exchanging parameter settings n n n n Enable/disable input n n n n n n n djustable debounce time and minimum signal time n n n n n n n Limit the number of telegrams n n n n n n n Device sends an In operation telegram n n n n Heating valve control (electric relay) n n n Switch LEDs n n n n = Function is supported 22 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

25 BB i-bus KNX Inputs BE/S Binary Inputs, V C/DC, MDRC Detects C/DC signals in the voltage range from V. The state of the input is displayed via yellow LEDs. The binary inputs enable detection of independent input signals. The devices feature a manual operation pushbutton for each channel. The devices are powered via the BB i-bus and do not require an additional power supply. unit 4-fold 2 BE/S CDG110091R fold 4 BE/S CDG110093R BE/S Binary Inputs, Contact Scanning, MDRC Scans floating contacts with internally generated scanning voltage. The state of the input is displayed via yellow LEDs. The binary inputs enable detection of independent input signals. The devices feature a manual operation pushbutton for each channel. The devices are powered via the BB i-bus and do not require an additional power supply. unit 4-fold 2 BE/S CDG110090R fold 4 BE/S CDG110092R US/U 4.2 Universal Interface, FM The universal interface has 2, 4 or 12 channels which can be parametrised as inputs or outputs with the ETS software. Conventional push-buttons, auxiliary contacts, LEDs and the electronic relay ER/U can be connected. The connecting cables can be extended up to 10 m. The contact scanning voltage and the supply voltage for the LEDs are made available by the device, the series resistors for the LEDs are integrated. unit 2-fold US/U 2.2 GHQ R fold US/U 4.2 GHQ R fold US/U CDG110065R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

26 BB i-bus KNX Inputs 5 E/S E/ 2.1 E/S 4.2 nalogue Input, 4-fold, MDRC NEW nalogue Input, 2-fold, SM Used wherever analogue variables should be detected. The sophisticated housing concept of the surface mounted device and the new screw terminals of the MDRC device enable quick and clear wiring and improve the speed of connection of the sensors. Comprehensive range of adjustment for many typical sensors (1 10 V, 0(4) 20 m, 0 1 V, PT 100, PT 1000, ) for detection of temperature, brightness, fill levels, etc. For active sensors the auxiliary voltage is supplied by E/S ; in case of E/ 2.1 a separate auxiliary voltage supply is required. vailability January 2015 unit 4-fold, MDRC 4 E/S CDG110190R fold, SM E/ 2.1 2CDG110086R nalogue Input, 4-fold, MDRC To be discontinued It is used to detect and process 4 independent analogue input signals according to IEC (0 1 V, 0 5 V, 0 10 V, 1 10 V, 0 20 m, 4 20 m, Ohm, PT 100 in 2-wire technology and floating contacts). The 24 V DC voltage for the sensors (max. 300 m) is also supplied by the device. The mains voltage supply is V C, 50/60 Hz. unit 4 E/S 4.2 2CDG110030R WZ/S Weather Unit, MDRC and Weather Sensor, SM NEW It is used to detect and process weather data from weather sensor. It supplies data for twilight and brightness levels in 3 directions, rain, temperature, information on day/night, wind speed, date and time. n additional input for the connection of a PT sensor is provided. Four value memories which can store up to 24 values each are available. The Weather Unit WZ/S can be operated either with the new Weather Sensor WES/ 3.1 or with the former sensor WES/ 2.1. The Weather Unit also provides the supply voltage for the connected sensor. The Weather Unit has to be supplied with a operating voltage of 85 to 265 V C. The Weather Unit supports the BB i-bus Tool for advanced diagnosis and improved commissioning. WES/ 3.1 The Weather Sensor WES/ 3.1 detects twilight, brightness in three directions, rain, temperature, day/night, wind speed and the date and time using a GPS module. n additional heating transformer is not required. The new Weather Sensor WES/ 3.1 can be connected to the new Weather Unit WZ/S or to the former Weather Unit WZ/S 1.1. vailability January 2015 unit Weather Unit 4 WZ/S CDG110184R Weather Sensor WES/ 3.1 2CDG120046R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

27 BB i-bus KNX Inputs WZ/S 1.1 Weather Unit, MDRC and Weather Sensor, SM To be discontinued It is used to detect and process weather data from weather sensor. It supplies data for twilight and brightness levels in 3 directions, rain, temperature, information on day/night, wind speed, date and time (DCF radio receiver). Four value memories which can store up to 24 values each are available. The Weather Unit WZ/S 1.1 is has been configured for the Weather Sensor WES/ and supplies it with power. The device can be operated optionally with a operating voltage of 115 to 230 V C, 50/60 Hz. 5 WES/ 2.1 The Weather Sensor WES/ 1.1 detects twilight, brightness in three directions, rain, temperature, day/night, wind speed and the date and time using the radio receiver. n additional heating transformer is not required. unit 4 WZ/S 1.1 2CDG110034R WES/ 2.1 2CDG120033R WS/S Weather Station, 4-fold, MDRC NEW ll common weather sensors for wind speed, wind direction, rain, amount of rain, brightness, light intensity, pyranometers, twilight, air pressure, humidity or temperature can be connected to the device. The power supply generates the 24 V DC voltage for external sensors (max. 300 m). The device can be operated with 85 to 265 V C, 50/60 Hz. The application software is configured for the detection of weather based data and enables quick sensor programming. The Weather Station supports the BB i-bus Tool for advanced diagnosis and improved commissioning. vailability January 2015 unit 4 WS/S CDG110191R WS/S 4.1 Weather Station, 4-fold, MDRC To be discontinued ll common weather sensors for wind speed, wind direction, rain, amount of rain, brightness, light intensity, pyranometers, twilight, air pressure, humidity or temperature can be connected to the device. The power supply generates the 24 V DC voltage for external sensors (max. 300 m). The device can be operated with 115 to 230 V C, 50/60 Hz. The application software is configured for the detection of weather based data and enables quick sensor programming. unit 4 WS/S 4.1 2CDG110032R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

28 BB i-bus KNX Outputs Complete Switch ctuator Range 6 Switch ctuators are responsible for reliable switching of different electrical loads in the KNX system. Many different load situations are possible. BB offers a suitable Switch ctuator for all application areas. The range has been rounded off with a new series. Now 16/20 X C-Load Switch ctuators with and without a current detection feature are available; each featuring 2, 4, 8 or 12 outputs. In the following table, you will find an overview of the BB i-bus Switch ctuators and their type designations: S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S Note: The codes represent the following: S/S S/S x. S/S 8.y. S/S S/S S/S S/S S/S z = Switch ctuator, DIN Rail mounting x = Number of outputs y = Rated current in mpere 1 = Standard without manual operation 2 = With manual operation 5 = C-Load (200 µf) 6 = C-Load with current detection z = Version 26 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

29 BB i-bus KNX Outputs Switching Capacity Overview The following table provides and overview of the rated values, switching performance, lamp loads or the number of lamps, which can be connected to a contact: 6 S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S I n rated current () 6 6 X 10 X 16 16/20 X C-Load 16/20 X C-Load U n rated voltage (V) 250/440 V C 250/440 V C 250/440 V C 250/440 V C 250/440 V C 250/440 V C C1 operation (cos ϕ = 0.8) DIN EN C3 operation (cos ϕ = 0.45) DIN EN ) C-Load switching capacity Fluorescent lighting load X to EN (35 μf) 3) 6 X (140 μf) 3) 10 X (140 μf) 3) 16 (70 μf) 3) 20 X (200 μf) 3) 20 X (200 μf) 3) Minimum switching capacity 10 m/12 V 100 m/12 V 100 m/12 V 100 m/12 V 100 m/12 V 100 m/12 V DC current switching capacity (resistive load) 7 /24 V = 6 /24 V = 10 /24 V = 16 /24 V = 20 /24 V = 20 /24 V = Mechanical service life > 10 7 > 3 x 10 6 > 3 x 10 6 > 3 x 10 6 > 10 6 > 10 6 Electronic endurance to IEC : Rated current C1 (240 V/0.8) 100, , , , , ,000 Rated current C3 (240 V/0.45) 15,000 30,000 30,000 30,000 30,000 30,000 Rated current C5a (240 V/0.45) 15,000 30,000 30,000 30,000 30,000 30,000 Incandescent lamp load at 230 V C 1,200 W 1,380 W 2,500 W 2,500 W 3,680 W 3,680 W Fluorescent lamp T5 / T8: Uncorrected 800 W 1,380 W 2,500 W 2,500 W 3,680 W 3,680 W Parallel compensated 300 W 1,380 W 1,500 W 1,500 W 2,500 W 2,500 W DUO circuit 350 W 1,380 W 1,500 W 1,500 W 3,680 W 3,680 W Low-voltage halogen lamps: Inductive transformer 800 W 1,200 W 1,200 W 1,200 W 2,000 W 2,000 W Electronic transformer 1,000 W 1,380 W 1,500 W 1,500 W 2,500 W 2,500 W Halogen lamp 230 V 1,000 W 1,380 W 2,500 W 2,500 W 3,680 W 3,680 W Dulux lamps: Uncorrected 800 W 1,100 W 1,100 W 1,100 W 3,680 W 3,680 W Parallel compensated 800 W 1,100 W 1,100 W 1,100 W 3,000 W 3,000 W Mercury-vapour lamps: Uncorrected 1,000 W 1,380 W 2,000 W 2,000 W 3,680 W 3,680 W Parallel compensated 800 W 1,380 W 2,000 W 2,000 W 3,000 W 3,000 W Sodium-vapour lamps: Uncorrected 1,000 W 1,380 W 2,000 W 2,000 W 3,680 W 3,680 W Parallel compensated 800 W 1,380 W 2,000 W 2,000 W 3,000 W 3,000 W Max. peak inrush-current Ip (150 μs) Max. peak inrush-current Ip (250 μs) Max. peak inrush-current Ip (600 μs) Number of electronic ballasts (T5/T8, single element): 2) 18 W (BB ballasts 1 x 18 SF) 10 ballasts 23 ballasts 23 ballasts 23 ballasts 26 1) ballasts 26 1) ballasts 24 W (BB ballasts 1 x 24 CY) 10 ballasts 23 ballasts 23 ballasts 23 ballasts 26 1) ballasts 26 1) ballasts 36 W (BB ballasts 1 x 36 CF) 7 ballasts 14 ballasts 14 ballasts 14 ballasts 22 ballasts 22 ballasts 58 W (BB ballasts 1 x 58 CF) 5 ballasts 11 ballasts 11 ballasts 11 ballasts 12 1) ballasts 12 1) ballasts 80 W (Helvar EL 1 x 80 SC) 3 ballasts 10 ballasts 10 ballasts 10 ballasts 12 1) ballasts 12 1) ballasts 1) The number of ballasts is limited by the protection with B16/B20 circuit-breakers. 2) For multiple element lamps or other types, the number of electronic ballasts must be determined using the peak inrush current of the electronic ballasts. 3) The maximum peak inrush current may not be exceeded. 4) Not intended for C3 operation, see Technical Data for maximum C3 current. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

30 BB i-bus KNX Outputs n Overview of all Software Functions 6 The following table provides an overview of the functions possible with the Switch ctuators and their application programs: S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S S/S Type of installation MDRC MDRC MDRC MDRC MDRC MDRC Number of outputs 4/8/12 2/4/8/12 2/4/8/12 2/4/8/12 2/4/8/12 2/4/8/12 Module width (space unit) 4/6/8 2/4/8/12 2/4/8/12 2/4/8/12 2/4/8/12 2/4/8/12 Manual operation Contact position display I n rated current () 6 6 X 10 X 16 16/20 X C-Load 16/20 X C-Load Current detection Switch function ON/OFF delay Staircase light Warning before end of staircase lighting Staircase lighting time set via object Flashing Switch response can be set (N.O./N.C.) Thresholds Current detection Threshold value monitoring Measured value detection Function Scene Function Logic Logic ND function Logic OR function Logic XOR function Gate function Priority object/forced operation Heating/fan control Switch ON/OFF (2 point control) Cyclical fault monitoring utomatic purging Fan Coil control 1) Special functions Default position on bus voltage failure/recovery Status messages 1) See special BB i-bus KNX devices of the HVC area, e.g. Fan/Fan Coil actuator LF/S or Fan Coil actuator FC/S. = possible functions 28 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

31 BB i-bus KNX Outputs S/S Switch ctuators, 6, MDRC Using floating contacts it switches 4, 8 or 12 independent electrical loads. The 6 -C3 devices are suited for switching resistive, inductive and capacitive loads. Please note: Increased module width compared to previous generation. unit 4-fold 4 S/S CDG110152R fold 6 S/S CDG110153R fold 8 S/S CDG110154R S/S Switch ctuators, 6, MDRC, Manual Operation Switches 2, 4, 8 and 12 independent electrical loads using floating contacts. Every output can be operated manually and features display of the switching state. The 6 -C3 devices are suited for switching resistive, inductive and capacitive loads. unit 2-fold 2 S/S CDG110180R fold 4 S/S CDG110181R fold 8 S/S CDG110182R fold 12 S/S CDG110183R S/S Switch ctuators, 10 X, MDRC Switches 2, 4, 8 and 12 independent electrical loads using floating contacts. Every output can be operated manually and features display of the switching state. The 10X-C1 devices are especially suited for switching resistive, inductive and capacitive loads such as fluorescent lighting (X) compliant to EN unit 2-fold 2 S/S CDG110155R fold 4 S/S CDG110156R fold 8 S/S CDG110157R fold 12 S/S CDG110158R S/S Switch ctuators, 16 C1, MDRC Switches 2, 4, 8 and 12 independent electrical loads using floating contacts. Every output can be operated manually and features display of the switching state. The 16-C1 devices are suited for switching resistive, inductive and capacitive loads. unit 2-fold 2 S/S CDG110159R fold 4 S/S CDG110160R fold 8 S/S CDG110161R fold 12 S/S CDG110162R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

32 BB i-bus KNX Outputs 6 S/S Switch ctuator, 16/20 X, C-Load, MDRC Uses floating contacts to switch independent electrical loads via BB i-bus KNX. Every output can be operated manually and features display of the switching state. The 16X-C3, C-Load devices are especially suited for switching loads with high surge currents such as luminaries with ballasts or fluorescent lighting (X) according to EN unit 2-fold 2 S/S CDG110132R fold 4 S/S CDG110133R fold 8 S/S CDG110134R fold 12 S/S CDG110137R S/S Switch ctuator with Current Detection, 16/20 X, C-Load Switches with floating contacts, 2, 4, 8 or 12 independent electrical loads with high surge currents. The Switch ctuators feature a circuit for high precision current detection for each output that is used to monitor the connected circuits. Every output can be operated manually and features display of the switching state. The 16/20, C-Load devices are especially suited for switching loads with high surge currents such as luminaries with ballasts or fluorescent lighting (X) according to EN unit 2-fold 2 S/S CDG110112R fold 4 S/S CDG110113R fold 8 S/S CDG110114R fold 12 S/S CDG110138R IO/S I/O ctuator, 6, MDRC For the control of loads in residential areas, typically in hotel rooms and apartments. The I/O ctuators provide binary inputs for the connection of conventional push-buttons and outputs for switching loads. Inputs and outputs can be internally connected by ETS. By integrating the devices into KNX networks further functions can be realised: e.g. central control or room based emergency calls to a control centre. unit 4-fold 4 IO/S CDG110168R fold 8 IO/S CDG110169R /S 4.1 nalogue ctuator, 4-fold and nalogue ctuator Module, 4-fold, MDRC The device outputs receives telegrams as analogue signals via four analogue outputs, which can be used independently from one another as current or voltage outputs. With the analogue actuator module M/S, the number of analogue outputs can be increased to 8 outputs. The devices requires an external 24 V power supply for operation. unit 4 /S 4.1 2CDG120005R M/S 4.1 2CDG120006R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

33 BB i-bus KNX Shutters and Sun Protection Modern building installation enables a high degree of functionality and simultaneously complies with increased security requirements. Due to the structured installation of the electrical components, it is possible to carry out rapid planning, installation and setup as well as achieve cost benefits during operation. 7 Modern sun protection devices have a significant role, as they must fulfil many demands: nti-glare protection (e.g. PC workstations) Utilization of daylight by tracking the sun s position and directing available daylight Protecting furniture and carpets from fading Regulating the room temperature (overheating protection in summer; harvesting the available energy on cold days) Providing protection from people looking in from the outside Protection against intruders. With the new Blind/Roller Shutter ctuators JR/S, the complex requirements on a sustainable and energy efficient automatic sun protection control can be implemented in offices, residential and functional buildings via BB i-bus KNX. The Blind/Roller Shutter ctuators are ideal for the control of drives in the area of sun protection: Blinds, exterior blinds, slat blinds and panel curtains Roller shutters, roller blinds, screens, vertical blinds wnings, pleated blinds, pleated curtains, etc. Optimum room air quality via automatic ventilation The demands for the reduction of energy consumption often results in poor ventilation in today s heavily insulated buildings. The quality of the room air does not comply with the desired and required level. Natural ventilation is often an effective and efficient method for exchanging the used room air and improving the air quality in the room. If the air quality in the room is monitored with sensors (temperature, humidity, CO 2 concentration), the ventilation flaps can be opened automatically and in good time ensuring that the air quality is kept in a comfortable range. Blind/Roller Shutter ctuators are ideal for control of ventilation elements such as Ventilation flaps Roof hatches, skylights Windows, doors and gates BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

34 BB i-bus KNX Shutters and Sun Protection Innovations 7 utomatic travel detection Travel times for the connected drives can be easily determined during operation with the automatic travel detection feature. It saves time during setup. Furthermore, compensation of age and weather-related length changes to blinds or roller shutters is assured. It facilitates precise positioning of the blinds/shutter when using sun position-dependent control. Diagnostics Enhanced diagnostic messages can be issued with the new Blind/Roller Shutter ctuators. They are particularly useful during setup or in the event of faults. It is possible, for example, to detect and signal if the power supply to a drive is interrupted. Copy and exchange This function allows parameter settings of an output to be copied or exchanged with other freely selectable outputs. This is possible within a device or in conjunction with several devices. Copy and exchange is useful particularly on projects, where all drives of a facade are controlled identically. It shortens the setup process and reduces the possible sources of error with parameterization. Integration in the room temperature control The intelligent and networked blind and roller shutter control plays an important role in the energy efficient usage of a building. The level of sunlight in the room and heating up due to the sun s energy can be controlled in conjunction with the room climate control. The new software function overheat control prevents unintentional overheating of a room. The blinds are closed in good time. The shutter control can be actively involved in the room temperature control a requirement for implementing high-efficient buildings compliant to EN CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

35 BB i-bus KNX Shutters and Sun Protection The following table provides an overview of technical data and software functions for the shutter actuator range: STNDRD SMI JR/S X JR/S JR/S X JR/S X SJR/S J/S 4.SMI.1M General Number of outputs X = 2, 4, 8 4 X = 2, 4, 8 X = 2, 4, 8 4 x 4 SMI LoVo (broadcast) 4 x 4 SMI (broadcast) Nominal voltage 230 V C 24 V DC 230 V C 230 V C LoVo 24 V 230 V uxiliary voltage 230 V Type of installation MDRC MDRC MDRC MDRC MDRC MDRC Module width (space unit) 2-fold: fold: 4 2-fold: fold: 4 8-fold: 8 4-fold: 4 8-fold: 8 4-fold: 4 8-fold: 8 Manual functions Disable/enable man. operation and status man. operation Operating modes Control with slat adjustment (blinds, etc.) Control without slat adjustment (roller shutters, awnings, etc.) Ventilation flaps, switch mode including stair case lighting function General device functions utomatic travel detection Time-delayed switching of drives Sending and switching delay time In operation function Request status values Extended setting options for drives and blind/shutter Direct functions UP/DOWN, STOP/Slat adjustment Position height/slat Preset Move to position/set position Enable limitation Trigger travel detection Trigger reference movement 8 bit scene Safety functions Wind, Rain, Frost alarm Block Forced operation (1-Bit and 2-Bit) utomatic functions ctivation of automatic control Position height/slat on sun Presence Heating/Cooling Overheat control Enable/block automatic Enable/block direct control Status messages Status height/slat Status upper/lower end position Status of operation Status automatic control Status information (2 byte) Status SMI Status of positions/limit position Status auxiliary voltage SMI diagnostic byte Sonstiges Extended settings for drives and blinds/shutters Total turning of slats after move down command Position of slat after arriving on lower end position Control and diagnosis via i-bus Tool 7 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

36 BB i-bus KNX Shutters and Sun Protection 7 JR/S Blind/Roller Shutter ctuator with Travel Detection and Manual Operation, 230 V C, MDRC For the control of independent 230 V C drives via BB i-bus KNX. The devices are designed for positioning blinds, roller shutters, awnings and other shading products as well as for controlling doors, windows and ventilation flaps. dditional auxiliary voltage is not needed. The travel times of the drive are detected automatically via current detection. To protect the drives, the output contacts are electromechanically locked against each other. Push buttons are located at the front of the device to control the outputs e.g. during commissioning. The current status of the output is displayed via LEDs. unit 2-fold 4 JR/S CDG110124R fold 4 JR/S CDG110125R fold 8 JR/S CDG110126R JR/S Blind/Roller Shutter ctuator with Travel Detection and Manual Operation, 4-fold, 24 V DC, MDRC For the control of up to 4 independent 24 V DC drives via BB i-bus KNX. The device is designed for positioning blinds, roller shutters, awnings and other shading products as well as for controlling doors, windows and ventilation flaps. dditional auxiliary voltage is not needed. The travel times of the drive are detected automatically via current detection. Push buttons are located at the front of the device to control the outputs e.g. during commissioning. The current status of the output is displayed via LEDs. unit 4 JR/S CDG110128R JR/S Blind/Roller Shutter ctuator with Manual Operation, 230 V C, MDRC For the control of independent 230 V C drives via BB i-bus KNX. The devices are designed for positioning blinds, roller shutters, awnings and other shading products as well as for controlling doors, windows and ventilation flaps. dditional auxiliary voltage is not needed. To protect the drives, the output contacts are electromechanically locked against each other. Push buttons are located at the front of the device to control the outputs e.g. during commissioning. The current status of the output is displayed via LEDs. unit 2-fold 4 JR/S CDG110120R fold 4 JR/S CDG110121R fold 8 JR/S CDG110122R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

37 BB i-bus KNX Shutters and Sun Protection JR/S Blind/Roller Shutter ctuator, 230 V C, MDRC For the control of independent 230 V C drives via BB i-bus KNX. The devices are designed for positioning blinds, roller shutters, awnings and other shading products as well as for controlling doors, windows and ventilation flaps. dditional auxiliary voltage is not needed. To protect the drives, the output contacts are electromechanically locked against each other. unit 2-fold 4 JR/S CDG110129R fold 4 JR/S CDG110130R fold 8 JR/S CDG110131R J/S 4.SMI.1M SMI Shutter ctuator with Manual Operation, 4-fold, MDRC It controls four independent groups (broadcast) with up to four SMI (Standard Motor Interface) drives (230 V) for positioning blinds, roller shutters, awnings and other shading products. Status signals (motor fault, direction of movement) can also be sent from the SMI drive on the bus. Push buttons are located at the front of the device to control the outputs e.g. during commissioning. The current status of the output is displayed via LEDs. unit 4 J/S 4.SMI.1M 2CDG110028R SJR/S SMI Blind/Roller Shutter ctuator, 4-fold, LoVo, MDRC It controls four independent groups (broadcast) with up to four SMI (Standard Motor Interface) LoVo drives for positioning blinds, roller shutters, awnings and other shading products. Status signals (motor fault, direction of movement) can also be sent from the SMI drive on the bus. Push buttons are located at the front of the device to control the outputs e.g. during commissioning. The current status of the output is displayed via LEDs. unit 4 SJR/S CDG110143R JSB/S 1.1 Shutter Control Unit, MDRC Controls shutter and blind actuators according to the position of the sun. The shutter control unit contains the functions of anti-glare protection and daylight redirection for up to 4 facades. utomatic shading can be implemented for every building and climatic control can be supported by the comprehensive range of parameter settings in the ETS. unit 2 JSB/S 1.1 GHQ R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

38 DLI Gateway DGN/S Lighting control and emergency lighting functions combined 8 DLI KNX DLI Gateway DGN/S Flexible group assignment DLI self-contained emergency lighting Manual light operation Operation/visualisation via touch display Control via 16 lighting groups Conventional lighting and individual emergency lighting battery combined The new BB i-bus KNX DLI Gateway with emergency lighting function combines modern flexible lighting control in intelligent building control systems with DLI emergency lighting. Up to 64 DLI devices can be flexibly installed via 16 lighting groups and controlled and monitored by KNX. Normal DLI lighting and DLI emergency lighting can be combined as required. Furthermore, the DLI gateway with emergency lighting function supports the DLI standard EN that specifies DLI emergency lighting with individual batteries. DLI Light Controller DLR/S M Energy through constant lighting control DLI DLI Light Controlller DLR/S M Flexible group assignment KNX Light Sensor Manual light operation Operation/visualisation via touch display The new DLI Light Controller DLR/ is a surface mounting device for switching and dimming of 8 independent lighting groups. maximum of 64 DLI devices can be connected. The device can be used for 4 - fold constant lighting control in connection with 4 Light Sensors LF/U 2.1. Furthermore staircase lighting and master / slave functions are provided. Fault feedback messages, e.g. concerning ballast or lamp failures, can be programmed and activated via KNX. The compact surface-mounted housing allows the decentralized installation in the underfloor or in false ceilings optimal for the use with Room Controller RC/. Control via 16 lighting groups. Up to 8 lighting groups can be controlled with 8 light sensors. Master-slave, staircase light and Scene mode round off the functions. DLI Light Controller DLR/ Decentralized Constant Lighting Control 36 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

39 = flexible connection DLI Gateway DG/S Flexibility in a good light DLI 8 DLI Gateway DG/S KNX Manual light operation = flexible KNX lighting groups Operation/visualisation via touch display Large lighting groups can be controlled via flexible DLI groups. 1 x 64 DLI devices in 16 lighting groups. Overlapping groups are possible. DLI Gateway DG/S 1.1 Individual lighting control DLI 12 DLI Gateway DG/S 1.1 KNX Manual light operation Operation/visualisation via touch display Lighting groups are formed in KNX. Individual lamps are indicated on the KNX. 1 x 64 DLI devices in unlimited lighting groups. = fixed connection DLI DLI Gateway DG/S 8.1 The proven technology DLI DLI DLI Gateway DG/S 8.1 KNX Manual light operation Operation/visualisation via touch display Lighting groups are formed via rigid hardware wiring. Fast commissioning as no addressing is necessary. No readdressing when a ballast is exchanged. 8 x 16 DLI devices. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

40 BB i-bus KNX Illumination and Light Sensors DLI 8 DG/S 8.1 DLI Gateway, 8-fold, MDRC For controlling up to 128 DLI devices. There are 8 separate, independent DLI outputs/channels available. Up to 16 DLI devices can be connected per channel. The DLI power supply is integrated in the gateway. The functions of switching, dimming, set values and fault indication for lamps and electronic ballasts are available for each output. It is possible to set the lamp burn-in time and 16 light scenes. Commissioning is simplified as no addressing or commissioning of the DLI devices is necessary. unit 6 DG/S 8.1 2CDG110025R DG/S 1.1 DLI Gateway, 1-fold, MDRC The device is used to interface between DLI and KNX installations and incorporates the DLI power supply. Up to 2 x 64 DLI devices can be connected. 64 devices can be individually switched, dimmed and controlled with a brightness value. The second 64 devices operate in broadcast mode. The DLI functions such as scene control or fault indication can be programmed and activated via the KNX. unit 4 DG/S 1.1 2CDG110026R DG/S DLI Gateway, 1-fold, Group Control, MDRC The device is used to interface between DLI and KNX installations and incorporates the DLI power supply. Up to 16 DLI devices can be assigned to 16 lighting groups. Each group can be switched, dimmed and controlled with a brightness value. Scenes and sequencer functions are available for lighting effects. Fault feedback messages can be programmed and activated via KNX. unit 4 DG/S CDG110103R DGN/S DLI-Gateway with Emergency Lighting Control, 1-fold, Group Control, MDRC For controlling DLI devices via the BB i-bus. Up to 64 DLI Slaves can be connected. Self contained emergency converter acc. EN will be supported. Control and status feedback is carried out via KNX with 16 lighting groups. By means of KNX and emergency converter different emergency tests (e.g. function and duration test) can be triggered. Feedback is sent. Slave-, staircase- and sequencer- function are integrated. For an individual change of the DLI address or group assignment a separate DGS-Software-Tool is available. unit 4 DGN/S CDG110142R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

41 BB i-bus KNX Illumination and Light Sensors DLI DLR/S M DLI Light Controller, 8-fold, MDRC For switching and dimming of 16 independent lighting groups. maximum of 64 DLI devices can be connected. The device can be used for 8-fold constant lighting control in connection with eight Light Sensors LF/U 2.1. Fault feedback messages can be programmed and activated via KNX. With comfortable manual operation and status display. unit 6 DLR/S M 2CDG110101R DLR/ DLI Light Controller, 4-fold, SM Surface mounting device for switching and dimming of 16 independent groups of luminaries. Up to 64 DLI participants can be connected to one DLI control line. When combined with the light sensor LF/U 2.1 the device can be used as a 8-fold light controller for constant light control. dditionally a staircase and master/slave function is integrated. great number of status feedback e.g. lamp and ballast fault can be transferred from DLI to KNX. With this functions the DLI light controller is a key factor in every energy efficient building automation. With his surface mounting housing it is possible to insert the device central in false ceiling or underfloor installation. unit DLR/ CDG110172R DS/S DLI Switch ctuator, 2-fold, 16 X, C-load, MDRC Uses floating contacts (N.O.) to switch 2 independent electrical loads. The devices are especially suited for switching resistive, inductive or capacitive loads with high surge currents. The device features a DLI interface to IEC The control is implemented via the DLI control signal. Both channels operate as two independent DLI devices. unit DS/S CDG110009R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

42 BB i-bus KNX Illumination and Light Sensors 8 LR/S Light Controller, 16, MDRC The device enables the switching and dimming of 2 or 4 independent lighting circuits in conjunction with electronic ballasts. In combination with the Light Sensor LF/U 2.1, the device can be used for constant lighting control. 2 or 4 light sensors can be connected to the controller for precise detection of the lighting conditions. unit 2-fold 4 LR/S CDG110087R fold 6 LR/S CDG110088R LF/U 2.1 Light Sensor, FM Used for implementing constant lighting control applications in conjunction with light controllers LR/S, LR/M, DLR/S M or DLR/ The scope of delivery includes different optical rods, the connection terminals and the cover for discrete fitting in a room. unit LF/U 2.1 2CDG110089R SD/S x.16.1 Switch/Dim ctuator, 16, MDRC Used for switching and dimming of 2, 4 or 8 independent groups of luminaries with electronic ballasts with 1 10 V control interfaces. On each channel the power supply of the ballasts is switched by a floating load relay (16 C1). Every output can be operated manually and features display of the switching state. The device can assume a range of applications thanks to the programming options. The switching load is identical to the S/S x range (see capital 6). unit 2-fold 4 SD/S CDG110079R fold 6 SD/S CDG110080R fold 8 SD/S CDG110081R UD/S Universal Dim ctuator, 2-fold, 300 V, MDRC For switching and dimming of incandescent lamps, 230 V halogen lamps or low-voltage halogen lamps which are powered by wound or electronic transformers (automatic load detection). Output power 2 x 300 V or 1 x 500 V up to 45 C ambient temperature at a minimum load of just 2 W. Both outputs are independent of one another and can be supplied by different phases. Comprehensive application program with scene and time functions. unit 4 UD/S CDG110074R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

43 BB i-bus KNX Illumination and Light Sensors 6197/ Universal Dim ctuator, MDRC Multi-channel universal dimming actuator for control of incandescent lamps, 230 V halogen lamps, lowvoltage halogen lamps with conventional or electronic transformers and dimmable energy-efficient lamps. Optimized for dimming of Philips retrofit LEDs (LEDi). Parallel connection of channels to increase load capacity via wire jumpers possible. Status/state indication of the outputs via LED. Local operation even without bus voltage or in non-programmed state possible. unit 4-fold, 210 V / fold, 315 V / fold, 315 V / fold, 600 V / fold, V / fold, V / HS/S Interface for Outside Light Sensor, MDRC The device is used for the connection and evaluation of up to 3 Outside Light Sensors LFO/ 1.1. The Outside Light Sensors can be analysed individually or combined. mongst others 10 logical switching channels for the evaluation of threshold values are provided. Threshold values can be adjusted directly on the device. The device can be used as a twilight switch ( lux) or as a light value switch ( lux). One Outside Light Sensor LFO/ 1.1 is supplied with the device. unit HS/S CDG120044R LFO/ 1.1 Outside Light Sensor Outside Light Sensor for the connection with the Interface HS/S unit LFO/ 1.1 2CDG120045R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

44 BB i-bus KNX Illumination and Light Sensors / Busch-Presence detector mini KNX NEW 8 meter Detection range (for mounting height 2.5 m, 3 m and 4 m): circular. Seated persons Ø: 5 m, 6,5 m and 9 m. Walking persons Ø: 6,5 m, 8 m and 10,5 m. Visible height 16 mm. With 2 channels. Targeted for connection and disconnection of lights bands depending on the room brightness. Regulation in response to the movement possible. Using the device as presence and/or movement detectors. Detectors application with 2 power off stages. Detectors application with integrated monitoring function. Constant light switch with up to two independent channels. Constant light switch with max. 2 outputs for brightnessdependent switching of two light bands in the area. With integrated KNX bus coupler. Connections: KNX-line: Bus connection terminal. Brightness limit value: 1 Lux 1000 Lux. Mounting height: 2 m 4 m. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 80 mm x 80 mm x 45 mm. Mounting depth: 29 mm. vailibility December 2014 unit alpine white 6131/ aluminium silver 6131/ / Busch-Presence detector mini premium KNX NEW 8 meter Detection range (for mounting height 2.5 m, 3 m and 4 m): circular. Seated persons Ø: 5 m, 6,5 m and 9 m. Walking persons Ø: 6,5 m, 8 m and 10,5 m. Visible height 16 mm. With 4 channels. For dimming/brightness of the rules to a defined value in a designated collection area. HVC function for controlling heating and/or cooling systems and ventilation systems in the designated collection area. Detectors application with 2 power off stages. Detectors application with integrated monitoring function. Constant light controller with up to two independent channels. Constant light controller with max. 2 outputs for dimming daylight control/rules of two rooflights in the room. Integrated object room temperature controller. 10 freely programmable IR channels (white). Incl. 5 logic channels (logic gates, gates, delay and staircase lighting). ing of up to 2 external brightness values and the internal brightness sensor possible. With integrated KNX bus coupler. Connections: KNX-line: Bus connection terminal. Brightness limit value: 1 Lux 1000 Lux. Mounting height: 2 m 4 m. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 80 mm x 80 mm x 45 mm. Mounting depth: 29 mm. vailibility December 2014 unit alpine white 6131/ aluminium silver 6131/ CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

45 BB i-bus KNX Illumination and Light Sensors 6131/ Busch-Presence detector KNX NEW 12 meter Detection range (for mounting height 2.5 m, 3 m and 4 m): circular. Seated persons Ø: 8 m, 10 m and 14 m. Walking persons Ø: 10 m, 12 m and 16 m. Visible height 23 mm. With 2 channels. Targeted for connection and disconnection of lights bands depending on the room brightness. Regulation in response to the movement possible. Using the device as presence and/or movement detectors. Detectors application with 2 power off stages. Detectors application with integrated monitoring function. Constant light switch with up to two independent channels. Constant light switch with max. 2 outputs for brightnessdependent switching of two light bands in the area. With integrated KNX bus coupler. Connections: KNX-line: Bus connection terminal. Brightness limit value: 1 Lux 1000 Lux. Mounting height: 2 m 4 m. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 91 mm x 91 mm x 45 mm. Mounting depth: 22 mm. vailibility December 2014 unit alpine white 6131/ aluminium silver 6131/ / Busch-Presence detector premium KNX NEW 12 meter Detection range (for mounting height 2.5 m, 3 m and 4 m): circular. Seated persons Ø: 8 m, 10 m and 14 m. Walking persons Ø: 10 m, 12 m and 16 m. Visible height 23 mm.with 4 channels. For dimming/brightness of the rules to a defined value in a designated collection area. HVC function for controlling heating and/or cooling systems and ventilation systems in the designated collection area. Detectors application with 2 power off stages. Detectors application with integrated monitoring function. Constant light controller with up to two independent channels. Constant light controller with max. 2 outputs for dimming daylight control/rules of two rooflights in the room. Integrated object room temperature controller. 10 freely programmable IR channels (white). Incl. 5 logic channels (logic gates, gates, delay and staircase lighting). ing of up to 2 external brightness values and the internal brightness sensor possible. With integrated KNX bus coupler. Connections: KNX-line: Bus connection terminal. Brightness limit value: 1 Lux 1000 Lux. Mounting height: 2 m 4 m. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 91 mm x 91 mm x 45 mm. Mounting depth: 22 mm vailibility December 2014 unit alpine white 6131/ aluminium silver 6131/ BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

46 BB i-bus KNX Illumination and Light Sensors / Busch-Watchdog Sky KNX NEW 24 meter Detection range (for mounting height 6 m and 12 m): circular. Walking persons Ø: 18 m, 24 m. Visible height 23 mm. With 2 channels. Targeted for connection and disconnection of lights bands depending on the room brightness. Regulation in response to the movement possible. Use of the device as a movement detector. Detectors application with 2 power off stages. Detectors application with integrated monitoring function. Constant light switch with up to two independent channels. Constant light switch with max. 2 outputs for brightnessdependent switching of two light bands in the area. With integrated KNX bus coupler. The programming button can be activated with the IR transmitter (-500). Connections: KNX-line: Bus connection terminal. Brightness limit value: 1 Lux 1000 Lux. Mounting height: 4 m 12 m. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 91 mm x 91 mm x 45 mm. Mounting depth: 22 mm. vailibility December 2014 unit alpine white 6131/ / Surface-mounting box NEW For Busch-Presence detector mini KNX. For installing a Busch-Presence detector mini KNX 6131/20-xxx(-500) or a Busch-Presence detector mini premium KNX 6131/21-xxx(-500). Protection class (Device): IP 20. Dimensions: (L x W x D): 80 mm x 80 mm x 35 mm. vailibility December 2014 unit alpine white 6131/ aluminium silver 6131/ / Surface-mounting box NEW For Busch-Presence detector KNX and Busch-Watchdog Sky KNX. For installing a Busch- Presence detector KNX 6131/30-xxx(-500) or a Busch-Presence detector premium KNX 6131/31-xxx(-500) or a Busch-Watchdog Sky KNX 6131/40-24(-500). Protection class (Device): IP 20. Dimensions: (L x W x D): 91 mm x 91 mm x 33 mm. vailibility December 2014 unit alpine white 6131/ aluminium silver 6131/ CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

47 BB i-bus KNX Illumination and Light Sensors 6131/ Presence Detector, FM To be discontinued with intergrated bus coupling unit. Standard version for switching illumination in conjunction with brightness and movement. With two switching channels and two constant brightness switching channels (control of switch actuators via adjusted brightness level). Detection zone (installation height = 2,5 m) circular Detection zone (installation height = 2,5 m) circular Ø 8 m. Detection angle: 360. Brightness limit value: Lux. Mounting height: 2,5 m recommended. Protection class (device): IP 20. unit alpine white 6131/ aluminium silver 6131/ / Presence Detector, DualLine, FM To be discontinued with intergrated bus coupling unit. DualLine version for switching illumination in conjunction with brightness and movement. With two switching channels and two channels for constant brightness control (control of dimactuators via adjusted brightness level). With two HVC channels. With logic functions and IR receiver. Detection zone (installation height = 2,5 m) circular Detection zone (installation height = 2,5 m) circular Ø 8 m. Detection angle: 360. Brightness limit value: Lux. Mounting height: 2,5 m recommended. Protection class (device): IP 20. unit alpine white 6131/ aluminium silver 6131/ Surface Mounting Base for Presence Detector To be discontinued Surface mounting base for for installation of flush-mounted inserts in combination with presence detector 6131/10 and 6131/11. unit alpine white aluminium silver BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

48 BB i-bus KNX Illumination and Light Sensors / Busch-Watchdog 220 MasterLINE KNX Sensor angle: 220 Range: approx. 16 m. With 2 movement channels. With 1 twilight channel with 3 switching thresholds. No remote control possible via IR remote control KNX. With integrated KNX bus coupler. No additional power supply necessary. Surveillance density: 92 sectors with 368 switching segments. Twilight sensor: approx lux. Switch-off delay: approx. 10 sec to 1092 min. unit white 6179/ silver metallic 6179/ / Busch-Watchdog 220 MasterLINE KNX premium Sensor angle: 220 Range: approx. 16 m. With 4 movement channels. With 1 twilight / brightness channel with 3 switching thresholds. With 1 temperature channel with three switching thresholds. With 7-channel IR remote control. Remote control possible via IR remote control KNX 6179 (included in scope of delivery). With integrated KNX bus coupler. No additional power supply necessary. Surveillance density: 92 sectors with 368 switching segments. Twilight sensor: approx lux; Brightness sensor: approx klux; Temperature sensor: approx. 25 to + 55 C; Switch-off delay: approx. 10 sec to 1092 min. unit white 6179/ silver metallic 6179/ IR Remote Control KNX For Busch-Watchdog 220 MasterLINE KNX premium. The functions can be freely assigned. With coded transmission signal. Power supply: lithium button cell battery. Type CR2025 (included in delivery). Battery life: typically 2 years. Rated voltage: 3 V, Protection class (Device): IP 40, Temperature range (Device): 0 C 45 C, Dimensions: (L x W x D): 86 mm x 40 mm x 7 mm. unit grey / anthracite CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

49 BB i-bus KNX Heating and Cooling Influencing Variables on Room Climate 9 Influencing Variables on Room Temperature Internal and external factors have an effect on the thermal conditions in a room or a building. s an external factor the solar radiation is important for the indoor temperature particularly with regard to modern architecture with glass fronts. Besides this, the room temperature is strongly affected by the exchange of thermal energy through windows and walls as well as the loss of thermal energy through open doors and windows. Depending on the intensity, all this interactions influence also the energy efficiency of a building and have therefore to be optimised. Internal thermal inputs from lighting, devices or persons have also an influence on the room climate. By planning a heating, ventilation or air conditioning system all this internal and external factors have to be considered. Influencing Variables on ir Quality The indoor climate in living and working areas has a scientifically proven impact on health, job performance and well-being of people. suitable indicator for determination of the room air quality is the CO 2 concentration. In addition the values for room temperature and air humidity must be controlled to meet the requirements for a comfortable room climate. Studies have shown, that high CO 2 concentration in the air influences the well-being as well as the performance and learning ability of people. Besides the normal CO 2 concentration in the air, human respiration is an important factor increasing the CO 2 concentration in a room. Therefore it is important to measure the CO 2 concentration in rooms where many persons are present (schools, conference rooms, open-plan offices). Monitoring of thresholds enables fans to be switched via BB i-bus KNX allowing automatic control of the CO 2 concentration and sufficient supply of fresh air. Loss of thermal energy through open doors CO 2 Thermal input from sun, lighting, persons and devices Exchange of thermal energy through windows and walls BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

50 BB i-bus KNX Heating and Cooling Room Thermostat FanCoil 9 Living and working with a feeling of well-being. nd here the air in the room is one of the most important factors. Because the body takes an ideal temperature for granted and therefore easily reacts to changes. Heated or air-conditioned rooms can be optimally adjusted to a consistently pleasant ambience. The KNX Fan Coil room temperature controller for stand-alone applications. The Fan Coil room temperature controller with display is a room temperature controller for ventilator convectors or conventional systems for heating and cooling. This option offers complete air-conditioning for rooms. The temperature can be adjusted precisely for personal comfort. The fan speeds can be selected by push buttons. Even very large rooms can be heated or cooled to a comfortable temperature quickly with additional air-conditioning units. The KNX Fan Coil room temperature controller can be operated individually. The bus coupler is integrated into the control element. Function Temperature sensor RTC setting Illuminated display Fan Coil operation for heating and cooling Features Very easy to operate with large, clear display Complete air conditioning Fan speeds can be manually selected Integrated bus coupler Surface-mounted, independent switching program Colours: studio white, aluminium silver 48 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

51 BB i-bus KNX Heating and Cooling ES/S Electronic Switch ctuator, 4-fold, 1, MDRC Controls thermoelectric valve drives (e.g. TS/K) in heating and cooling systems. Each output ( V C/DC) is protected against short-circuit and overload. With manual operation and status display for each output. unit 4-fold 4 ES/S CDG110058R fold 8 ES/S CDG110059R ER/U 1.1 Electronic Relay, 1-fold, FM The device combination with the Universal Interface US/U and a room thermostat noiselessly controls the heating system and chilled ceiling temperature via thermo-electric valve drives e.g. TS/K, 24 V 230 V C/DC). unit ER/U 1.1 GHQ R fold US/U 2.2 GHQ R fold US/U 4.2 GHQ R V/S Valve Drive ctuator, 230 V, MDRC Controls thermoelectric valve drives (e.g. TS/K) in heating or cooling systems. Each three outputs are protected against short-circuit and overload. With manual operation and status display. unit 6-fold 4 V/S CDG110116R fold 8 V/S CDG110117R V/ Valve Drive ctuator, 6-fold, 24 V, SM In conjunction with the thermostat it controls up to 13 thermoelectric valve drives (24 V), max. 4 per channel. The device is suitable for the installation in heating circuit distribution systems where the application of a triac ensures noiseless switching of the drives. Mains plug on the transformer (230 V) for ease of installation. unit V/ CDG120032R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

52 BB i-bus KNX Heating and Cooling 9 FCL/S Blower ctuator, 6, MDRC NEW to control blowers or fans with up to three fan speeds via step or changeover control. The FCL/S have one fan output and one additional floating switch output. The FCL/S feature two fan outputs plus two floating switch outputs. lternatively the second fan output can be used as three switch outputs. The fan speed can be directly choosen, increased and decreased as well as controlled by the control value of a closed-loop controller. unit 1-fold 4 FCL/S CDG110163R fold 6 FCL/S CDG110164R FCL/S / Room Thermostat Fan Coil with Display, SM Sends control values for the room to the Fan Coil ctuators or devices with the respective outputs (e.g. Room Master). The intuitive control operation allows each user to individually set the room temperature and the fan speed. The large LC display can display the actual and target temperatures, the current operating mode as well as the fan speeds. With integrated Bus Coupler. unit alpine white 6138/ aluminium silver 6138/ FC/S 1.1M Fan Coil ctuator, MDRC For the control of typical blower convectors via two electronic outputs for thermoelectric or motor-driven valve drives (FC/S 1.1M) or via two analogue outputs for V valve drives (FC/S ). Furthermore 3 outputs for individual fan speeds are provided. n additional load output switches an additional load (up to 16 ), such as auxiliary heating. window contact and a condensed water signal can be read via two binary inputs and transferred on the KNX. The easy to understand manual operation enables quick commissioning. unit For thermoelectric or 4 FC/S 1.1M 2CDG110084R motor-driven valve drives For V valve drives 6 FC/S CDG110141R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

53 BB i-bus KNX Heating and Cooling FC/S 1.1 Fan Coil Controller, MDRC It controls motor-driven and thermoelectric valve drives as well as multi-speed fans. Control without further additional components can be undertaken in combination with the optional Temperature Sensor TS/K. There are two binary inputs available for 24 V C signal contacts for window contact or dew point signals. 230 V power supply is required. unit 6 FC/S 1.1 2CDG120001R Temperature Sensor for FC/S 1.1 TS/K 1.1 2CDG120002R LGS/ 1.1 ir Quality Sensor, SM ccurately measures the CO 2 concentration, humidity and temperature in a room. Three independent thresholds can be set for the CO 2 concentration and the relative humidity in addition to a threshold for the temperature. Exceeding or underrunning the thresholds can trigger a response. Disable object for every threshold. Measured variables can be transmitted directly on the bus. Communication object Ventilation is used for RPM control or as a position indicatior for the ventilation flaps. Maintenance free sensor. The sensor is powered via the bus. With integrated Bus Coupler. unit LGS/ 1.1 2CDG120038R ST/K 1.1 Electromotor Valve Drive The drive is a proportional valve drive for controlling heating valves and is mounted on thermostat valve bases. Valve dapters V10, V78 for conventional valves are supplied. The control is carried out via a continuous KNX room thermostat. The actual valve position is indicated by 5 LEDs. The valve drive has two binary inputs for a presence contact and/or window contact and for further signal indication. unit ST/K 1.1 2CDG120004R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

54 BB i-bus KNX Heating and Cooling 9 TS/K Thermoelectric Valve Drives For opening and closing valves in heating, ventilation and air-conditioning systems. Both variants (230 V and 24 V) feature a plug-in connection cable (1 m) and a splash-proof housing. The mounting on the valve is easily implemented using the Valve dapter V/Z xx.1. unit 230 V TS/K CDG120007R V TS/K CDG120008R Valve dapter for valves V/Z CDG120009R from Dumser, Chronatherm, Vescal, KaMo Valve dapter for valves V/Z CDG120010R from Honeywell, Reich, Cazzaniga, Landis & Gyr. MNG Valve dapter for valves V/Z CDG120011R from Danfoss R Valve dapter for valves from Heimeier, Herb, Onda, Schlösser (ab 93), Oventrop V/Z CDG120012R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

55 BB i-bus KNX Control, Logic and Time LM/S 1.1 Logic Module, MDRC Used to solve a varied range of project-specific control tasks and can implement 3 functions simultaneously. The following functions are available for selection: logic gate, filter, time delay, multiplier, min/max value detector, temperature comparator, toggle values, threshold detection, format converter, scenes, increment/decrement values, staircase lighting. unit 2 LM/S 1.1 GHQ R BL/S 2.1 pplication Unit, Logic, MDRC llows the compilation of complex logical functions by simply combining different logic elements and gates using a graphical user interface as an ETS plug-in and does not require additional software. 50 logical elements, 50 gates, 30 timer modules and 10 comparators are available. unit 2 BL/S 2.1 2CDG110073R BZ/S 2.1 pplication Unit, Time, MDRC It provides a yearly time clock program with 15 daily routines (800 switching events), a weekly schedule and allowance for 100 special days. dditionally, the unit can control up to 300 participants in 30 macro groups, that can be triggered using a single command. In this way, each time controlled switching event can cause a series of actions. The switching times can be modified with the free PZM software without using ETS. PZM Software and additional information on unit 2 BZ/S 2.1 2CDG110072R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

56 BB i-bus KNX Control, Logic and Time 10 FW/S Radio Time Switch, 8-channel, MDRC The Radio Time Switch sends current time and date on the bus. The time can be optionally received via a DCF or GPS antenna. Furthermore the device can be used to easily adjust the time programs. The device provides 8 channels. Every channel supplies an independent daily, time and/or yearly program. dditionally, special programs (e.g. for vacation or public holiday days) are possible. unit 3 FW/S CDG120039R FD/ 1.1 DCF ntenna for Radio Time Switch For the connection to the Radio Tme Switch FW/S The time signal from the DCF 77 transmitter can be received within a radius of approx km around Frankfurt. unit FD/ 1.1 2CDG120040R FG/ 1.1 GPS ntenna for Radio Time Switch For the connection to the Radio Time Switch FW/S The device receives time and date via GPS signal which is available worldwide. unit FG/ 1.1 2CDG120041R PS/E 2.1 Programming Set OBELISK top2 for Radio Time Switch The programming set contains a CD ROM with the Obelisk top2 for the creation of switching programs for the Radio Time Switch FW/S 8.2.1, a memory card PK/E 2.1 for transferring switching programs to the Radio Time Switch and a USB programming adapter for the memory card. unit PS/E 2.1 2CDG120042R PK/E 2.1 Memory Card OBELISK top2 The memory card can be used for transferring switching programs to Radio Time Switch. unit PK/E 2.1 2CDG120043R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

57 BB i-bus KNX Visualisation, Display and Signalling TG/S 3.2 Telephone Gateway, nalogue, MDRC It sends configurable voice messages via the telephone network to up to 10 users. 100 objects are available in the ETS program as inputs and outputs. s well as voice messages, s or SMS messages can be sent. If the device is called, states can be polled and commands executed. The device has an integrated web server which enables simple operation and parametrisation using a conventional browser. unit 11 ccessory Set contains a crossover cable (RJ45), a telephone cable (RJ11) and a TE adapter for the telephone cable. 8 TG/S 3.2 2CDG110135R TG/Z 1.1 2CDG110119R Universal I/O Concentrator, 32-fold, MDRC Used to connect push buttons or signal lamps, e.g. to an operating/display tableau. It has 32 channels which can be freely parameterised as inputs/outputs using the ETS software. The device requires an external 12 or 24 V DC auxiliary power supply, (e. g. NT/S ). UK/S 32.2 unit 4 UK/S CDG110071R Control and Display Tableau, LCD For indication of switching status, fault reports and measurement values. Using the robust push buttons, electrical consumers can be manually switched, values can be set in addition to timer programs and light scenes. The alarms can also issue an acoustic warning. The FM wall box simplifies mounting. MT 701.2, WS with T-RHM, WS unit white MT 701.2, WS GHQ R silver MT 701.2, SR GHQ R Coverframe, white T-RHM, WS GHQ R Coverframe, silver T-RHM, SR GHQ R Wall box UP-KST 2 GHQ R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

58 BB i-bus KNX Visualisation, Display and Signalling Busch-ComfortTouch 11 The Busch-ComfortTouch offers not only an extremely versatile range of switching and control functions for KNX systems, but also satisfies the highest design requirements. Its unique colour coding concept makes for particularly easy operation. Busch-ComfortTouch unites the functions of a home control system, an information and entertainment centre with the highest design requirements. You can use Busch-ComfortTouch to switch lamps on and off, dim them, control blinds, room temperature or select scenes comprising a combination of the above-named functions even via remote control. There is also an integrated audio and video player. These functions are not only of interest for private households the system is often used in doctor s surgeries, offices, restaurants or stores to provide attractive lighting, soft bacround music or comfortable room climates. presence simulation function and alarm message display provide added security. It is also possible to display images from surveillance cameras. The system can be connected to the Internet, enabling you to call up s, the latest stock market news, the weather forecast or traffic information. Operation is simple and easy via touch screen. menu created individually for the user with clearly assigned buttons and a unique colour coding concept allow simple and intuitive operation. 01 Simplicity and user-friendliness are always the top priorities for operation. Busch-Jaeger has developed a unique colour coding concept for the user interface of its intelligent home control system. Each comfort area is assigned a specific colour. Yellow stands for lighting, blue for the blind control unit, magenta for light scenes and orange for the heating control unit. These colours are also used in the menus on the display. 01 Busch-ComfortTouch 12.1 Glass black 02 Busch-ComfortTouch 9 Glass black 03 Busch-ComfortTouch 9 White glass 04 Busch-ComfortTouch 12.1 Glass black 05 Busch-ComfortTouch 12.1 White glass CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

59 BB i-bus KNX Visualisation, Display and Signalling Busch-ComfortTouch 11 The system is controlled via the Busch-ComfortTouch it couldn t be easier. Buttons with text and symbols allow intuitive operation. Just a touch of the finger, and you can call up the MP3-player and play individual titles or playlists. nd the volume is regulated via the panel, too. The ideal solution, not only for homes the system is, for example, popular in restaurants. No more CDs lying around, no more finding space for a conventional hifi centre. The system can also be used to call up light scenes for various situations, from a cosy dinner at home to night-time lighting for store windows, at the press of a button or via a time-controlled function. nother useful feature is the handy memo field allowing you to write text by hand - use it, for example to write a shopping list or for leaving messages for others. Colour pictures from surveillance cameras on stairways or outside the building can be called up on the display, offering added security. This allows you to keep an eye on the building at all times handy, for example, for checking the surrounding area before opening the door for customers in the morning or when the doorbell rings. Media player Video surveillance Door communication Control of household appliance Dashboard Remote control by tablets (PP) Busch-ComfortTouch controllable via app BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

60 BB i-bus KNX Visualisation, Display and Signalling / Busch-ComfortTouch 9" Free programmable IP/KNX touch display can be used as a control, infotainment and entertainment centre for the whole house With a closed capacitative glass surface and a design strip made of stainless steel (brushed). With integrated camera and proximity sensor. Easy control using intuitive navigation concept. House control: switching, dimming, blinds, RTR, scene/sequences, timed controls Entertainment: Multimedia, remote control RC5 and B&O. Infotainment: IP telephony, RSS reader, intercom with picture, , voice and graphic memo, consumption data monitoring. Door communication: Indoor station for the BB-Welcome system in combination with IP gateway Safety: video surveillance with IP cameras, alarm function, message function, presence simulation. Representation from individual floor plans, room images and operation pages. 23 cm (9 ) Touch-display with 800 x 480 pixel Compatible with BB i-bus KNX Maintenance via remote control over IP. Control with smartphones and tablets via the ComfortTouch pp (pple ios /Google ndroid from Version 4). unit white glass 8136/ black 8136/ / Busch-ComfortTouch 12.1" Free programmable IP/KNX touch display can be used as a control, infotainment and entertainment centre for the whole house With a closed capacitative glass surface and a design strip made of stainless steel (brushed). With integrated camera and proximity sensor. Easy control using intuitive navigation concept. House control: switching, dimming, blinds, RTR, scene/sequences, timed controls Entertainment: Multimedia, remote control RC5 and B&O. Infotainment: IP telephony, RSS reader, intercom with picture, , voice and graphic memo, consumption data monitoring. Door communication: Indoor station for the BB-Welcome system in combination with IP gateway Safety: video surveillance with IP cameras, alarm function, message function, presence simulation. Representation from individual floor plans, room images and operation pages. 31 cm (12.1 ) touchdisplay with 1280 x 800 pixel. Compatible with BB i-bus KNX Maintenance via remote control over IP. Control with smartphones and tablets via the ComfortTouch pp (pple ios /Google ndroid from Version 4). unit white glass 8136/ black 8136/ /01 UP-500 Power adapter module BB i-bus KNX Power adapter for the power supply of Comfort-Touch 8136/09- and 8136/12-. With integrated KNX bus coupler for the establishment of the local bus connection to the BB i-bus KNX. With integrated audio outputs (LineOut). Rated voltage: 110 V~ 230 V~, +10% / 10%. Rated frequency: 50 Hz 60 Hz. unit 6186/01 UP CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

61 BB i-bus KNX Visualisation, Display and Signalling 8136/01 UP-500 Flush-mounted installation box For flush-mounted und hollow-wall installation of the Busch-ComfortTouch 8136/09-..., 8136/ or the SMRTtouch. Windproof. unit 8136/01 UP /100 C Controlpanel SMRTtouch The SMRTtouch (210 functions) offers a colour touch display. The panels clearly display switch states, error messages and measured values, and allow comfortable operation and setting of timing programs and light scenes. coustic warnings or alarm functions can be programmed. The integrated room thermostat can be integrated into room climate control. Commissioning is via the bus or multimedia card/sd card. For flush mounting in walls and hollow panels the wall box 6136/UP can be used. unit SMRTtouch, colour 6136/100 C (210 functions) Bang & Olufsen, colour 6136/100 CB (210 functions) 6136/ Design Frame for SMRTtouch Design frame made of real metal for 6136/100C xxx, 6136/100CB xxx, 6936/100C xxx, 6936/100CB xxx. Real metals: Dark glass with flap in chrome, dark glass with flap in aluminium, white glass satin finish with flap in aluminium. Dimensions (H x W x D): mm x 218 mm x 9 mm. unit Dark glass with flap 6136/ in chrome Dark glass with flap 6136/ in aluminium White glass, satin finish with flap in aluminium 6136/ /UP Flush Mounted Wall Box for Busch-Controlpanel To be discontinued For flush mounting and hollow panel mounting of the Room and Control Panels. Dimensions (H x W x D): mm x 199 mm x 60 mm. Mounting depth: 60 mm. unit 6136/UP BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

62 BB i-bus KNX Operation Unique diversity of the range CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

63 BB i-bus KNX Operation Unique diversity of the range carat 02 pure stainless steel 03 solo 04 Busch-axcent 05 future linear 06 Millenium* 07 Zenit for VDE markets 08 Zenit for NEM markets 09 Busch-triton 10 Busch-priOn 11 Bus Coupling Unit for all the conventional series of Busch-Jaeger** * Millenium and Zenit series are only available in selected markets. ** Busch Jaeger switch ranges only available for selected markets. For further information please contact your local BB office. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

64 BB i-bus KNX Operation Functional Overview 12 Program Standard control elements, bus coupler included with package Multifunction control elements, suitable for KNX bus coupler 6125/01 1gang 6126/01 2gang 6127/01 4gang 6125/02 1/2gang 6126/02 2/4gang 6127/02 4/8gang 6129/01 3/6gang with IR 6124/01 RTC 6128/01 2/4gang with RTC KNX function Switching, rocker switch total Switching, rocker switch left/right Dimming, rocker switch total Dimming, switch rocker left/right Blind switch rocker total Venetian blind switch rocker total left/right Short-long operation, switch rocker left/right Value sender rocker switch total Value sender switch rocker left/right Value dimming sensor, switch rocker total Red/green LED status illumination (red/green/off) Two LEDs per switch rocker RGB LED function illumination + status illumination Two LEDs per switch rocker Two LEDs per switch rocker Two LEDs per switch rocker Setting the RTC operating mode Value sender, 2 objects, switch rocker left/right Light scene extension unit with light scene memory function Level switch, switch rocker total Level switch, switch rocker total left/right Multiple operation, rocker switch left/right IR remote control channels (up to 5 channels) Two LEDs per switch rocker Room temperature controller only Temperature reading RTC settings Illuminated display Fan Coil operation for heating and cooling Logic function (including light scenes) Busch-Watchdog 4 channels Design series Reflex SI Busch Duro 2000 SI future linear alpha exclusive / nea Busch-axcent solo impuls pure stainless steel carat ocean ll Weather 44 Busch-priOn Busch-triton 62 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

65 BB i-bus KNX Operation Functional Overview 6120/ and 6120/13 FM push-button coupling unit with integrated bus coupler FM room temperature controller, comercial /01 Standard 6122/02 Comfort 6108/01 1/2gang 6108/02 2/4gang 6108/04 1/2gang 6108/05 2/4gang 6108/03 RTC 1 LED 1 LED BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

66 BB i-bus KNX Operation Functional Overview 12 Program Busch-triton (next generation) Monoblock Busch-priOn suitable for KNX bus coupler 6320/10 1/2gang 6320/30 3/6gang 6320/50 5/10gang 6320/38 3/6gang with RTC 6320/58 5/10gang with RTC 6340-xx-101 1/2gang 6341-xx-101 rotarycontrol element KNX function Switching, rocker switch total Switching, rocker switch left/right Dimming, rocker switch total Dimming, rocker switch left/right Blind switch rocker total Blind switch rocker total left/right Short-long operation, switch rocker left/right Value sender rocker switch total Value sender switch rocker left/right Value dimming sensor, switch rocker total Red/green LED status illumination (red/green/off) 1 LED per switch rocker 1 LED per switch rocker RGB LED function illumination + status illumination 1 LED per switch rocker 1 LED per button Setting the RTC operating mode Value sender, 2 objects, rocker switch left/right Light scene extension unit with light scene memory function Level switch, switch rocker total Level switch, switch rocker total left/right Multiple operation, rocker switch left/right - IR remote control channels (up to 13 channels) Light scene unit (8 scenes for up to 8 actuators) Light scene unit (10 scenes for up to 10 actuators) - Programmable shift key Proximity function Room temperature controller only Temperature reading RTC settings Illuminated display Fan Coil operation for heating and cooling Media box/cd/dvd/radio Short-time timer Weekly timer larm clock Messages Screen saver Display text/value Device lock Logic function (including light scenes) Busch-Watchdog 4 channels 64 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

67 BB i-bus KNX Operation Functional Overview 6120/ or 6120/13 (depending on the specific combination) xx-101 3/6gang 6344-xx cm (3.5") TFT colour display with rotary control element 6344-xx end strip top with information display, room temperature controller, IR receiver and proximity sensor xx-101 3/6gang end strip top with IR receiver and proximity sensor 6352-xx-101 end strip bottom with temperature sensor 1 LED per switch rocker 1 LED per switch rocker BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

68 BB i-bus KNX Operation Functional Overview 12 Program Millenium 6125/ /2gang 6126/ /4gang 6129/ /6gang 6129/ /6gang with IR 6122/ / KNX function Switching, button pair Switching, button upper/lower Dimming, button pair Dimming, button upper/lower Blind, button pair Blind, button upper/lower Short-long operation,button upper/lower Value transmitter, button pair Value transmitter, button upper/lower Value dimming sensor, button pair Value dimming sensor, upper/lower RGB LED function illumination + status illumination Setting the RTC operating mode Value transmitter, 2 objects, button upper/lower Light scene extension unit with light scene memory function Step switch, button pair Step switch, button upper/lower Multiple operation, botton upper/lower IR remote control channels (up to 5 channels) Room temperature controller only Temperature reading RTC settings Illuminated display Fan Coil operation for heating and cooling logic channels (incl. light scene, actuator, sequence actuator, logic gates, etc.) Busch-Watchdog 4 channels 66 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

69 BB i-bus KNX Operation Functional Overview Program Zenit (VDE and NEM) / /2gang 6126/ /4gang 6129/ /6gang 6129/ /6gang with IR 6122/ / KNX function Switching, button pair Switching, button upper/lower Dimming, button pair Dimming, button upper/lower Blind, button pair Blind, button upper/lower Short-long operation,button upper/lower Value transmitter, button pair Value transmitter, button upper/lower Value dimming sensor, button pair Value dimming sensor, upper/lower RGB LED function illumination + status illumination Setting the RTC operating mode Value transmitter, 2 objects, button upper/lower Light scene extension unit with light scene memory function Step switch, button pair Step switch, button upper/lower Multiple operation, botton upper/lower IR remote control channels (up to 5 channels) Room temperature controller only Temperature reading RTC settings Illuminated display Fan Coil operation for heating and cooling logic channels (incl. light scene, actuator, sequence actuator, logic gates, etc.) Busch-Watchdog 4 channels BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

70 BB i-bus KNX Operation Busch-priOn 12 Busch-priOn allows you to control and monitor functions for the entire room. Light, scenes, timer, blind control unit, heating control unit all functions are controlled simply and intuitively via a rotary dial, and freely programmable functions can be called up via the rocker switches. Busch-priOn is a non-fixed, modular concept Colours that make life easier. consistent colour coding concept and durable LED technology make Busch-priOn extremely easy to operate. The dial lights up in the colours of the coding system, thus providing feedback on the function currently selected. Yellow stands for lighting, blue for the blind control unit, magenta for light scenes and orange for the heating control unit. These colours are also found on the rocker switches of the control element panels. The rotary control element is equipped with a freely programmable button which can be pressed and turned. It can be used to switch and dim individual lamps, but also to switch on whole groups of lamps with one press of a button and vary their brightness continuously via the dial. Function Dimming Blinds Value Light scenes Logic functions Time functions Features Illuminated dial Colour coding concept nti-theft protection Day/night operation The single control element is equipped with a freely programmable large operating button. It can be assigned to one topic and can carry out a maximum of two commands. Function Switching Dimming Blinds Value Buttons Light scenes Logic functions Time functions Features Illuminated rocker switch Colour coding concept Freely programmable control button nti-theft protection Replaceable labelling symbol (Fig. shows Lighting labelling symbol) The triple control element is equipped with 3 freely programmable control buttons. Each can be assigned to one topic and can carry out a maximum of two commands. Function Switching Dimming Blinds Value Buttons Light scenes Logic functions Time functions Features Illuminated rocker switches Colour coding concept Freely programmable control buttons nti-theft protection Replaceable labelling symbol (Fig. shows labelling symbols Lighting, Blinds and Scene) 01 Rotary control element 02 1gang control element 03 3gang control element 04 Glass black 05 Studiowhite, glossy 06 Stainless steel 07 White glass CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 Busch-priOn received special commendment in the category best of the best, winning the red dot award: communication design 2008 for its interface design.

71 BB i-bus KNX Operation Busch-priOn single-line display with integrated room temperature controller has been designed for the Busch-priOn 3gang control element, technically reduced to the basics and optically elegant. It is particularly easy to read due to the monochromatic design for white on black information. The room temperature controller, information function like time and date, up to 17 freely programmable text displays, IR sensor and proximity sensor have been integrated into the display. The design of the display is available in the colour and material glass black only. The 8.9 cm (3.5 ) TFT display gives a clear overview of all information. The user can choose from 3 surface designs: black, blue and silver. The 8.9 cm (3.5 ) TFT display gives a clear overview of all information. Operation is simple intuitive, supported the colour coding concept. It is possible freely combine several Busch-priOn elements with each other. display and a special allow simple and convenient control. Blinds Climate control Scene 01 3gang control element with single-line display and temperature controller 02 2gang combination 03 3gang combination 04 carat glass black 05 Flush-mounted movement sensor Busch-priOn is a nonfixed, modular-design system. The rocker switches of the triple control element allow you to call up freely programmable functions such as light scenes, blind functions or specific lamps. Busch-priOn is ideal in combination with the carat switch series, which has surfaces in the same design. 05 The Busch-priOn flush-mounted movement sensor can be used individually or with other Busch-priOn modules. Practical because users thus do not have to look for the light switch and are greeted with light when first entering a dark room. Note: We can only give you a rough idea here of the wide range of combinations offered by this modular concept. For more detailed information, see our separate product brochure / planning aid or the catalogue. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

72 BB i-bus KNX Operation Planning aid for Busch-priOn End strips without function 12 studio white, rticle-no G white glass, rticle-no glass black, rticle-no stainless steel, rticle-no Support frame, bus coupler Bus coupler Busch-priOn, rticle-no. 6120/ gang, rticle-no. 6346/ Note: This power adaptor can supply up to 15 power bus couplers with current. FM actuators Power adaptor REG, rticle-no. CP-D 24/2.5 Bus coupler Busch-priOn, rticle-no. 6120/ Without end strip incl. temperature reading 2gang, rticle-no. 6346/ gang, rticle-no. 6346/ Switch actuator, 1gang, FM w/v, rticle-no U-500 Universal dimming actuator, 1gang, FM w/v, rticle-no U-500 Serial/blind actuator, 2/1gang, FM w/v, rticle-no U-500 End strip End strips without function studio white, rticle-no G Commissioning adaptor, rticle-no. 6149/ white glass, rticle-no glass black, rticle-no stainless steel, rticle-no CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

73 BB i-bus KNX Operation Planning aid for Busch-priOn End strip with IR proximity function Note: only combinable with 3gang control element Colour range 12 glass black, rticle-no Single-line display and room thermostat, rticle-no Control element, 1gang, rticle-no Control element, 3gang, rticle-no Busch-priOn glass black Busch-priOn white glass Colour display with rotary control element, rticle-no Rotary control element, 1gang, rticle-no Busch-Watchdog, 180 FM, rticle-no End strips with temperature sensor. Not combinable with FM actuators. Busch-priOn stainless steel Busch-priOn studio white, gloss studio white, rticle-no G white glass, rticle-no Labelling symbols glass black, rticle-no stainless steel, rticle-no Labelling inserts for blinds, lighting, RTC and scene. The colours are repeated in the Busch-Jaeger colour concept. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

74 BB i-bus KNX Operation Busch-priOn / Bus Coupler, FM for Busch-priOn support frame 1-fold 6346/10-10x and control elements 6122/0x-xxx, 6124/0x-xxx, 6125/0x-xxx, 6126/0x-xxx, 6127/0x-xxx, 6128/0x-xxx and 6129/0x-xxx. unit 6120/ swiss version 6120/ / Power Bus Coupler, FM, Busch-priOn For Busch-priOn base frame 1-fold, 2-fold and 3-fold. Separate power supply required. The KNX connection is used exclusively for bus communication. unit 6120/ swiss version 6120/ U-500 Switch ctuator/sensor, 1-fold, FM, Busch-priOn For switching incandescent lamps, 230 V halogen lamps, fluorescent lamps and low-voltage halogen lamps operated using transformers 3-wire technology (Neutral conductor required). Only in conjunction with a 2-fold and 3-fold base frame Cannot be combined with the lower finishing strip with temperature sensor. unit 6354 U U-500 Shutter/2-fold ctuator, FM, Busch-priOn Only in conjunction with a 2-fold and 3-fold base frame. Not suitable for switching fluorescent lamps, HQI lamps and HQL lamps. Cannot be combined with the lower finishing strip with temperature sensor. unit 6356 U U-500 Shutter/2-fold ctuator, FM, Busch-priOn Only in conjunction with a 2-fold and 3-fold base frame Not suitable for switching fluorescent lamps, HQI lamps and HQL lamps. Cannot be combined with the lower finishing strip with temperature sensor. unit 6355 U CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

75 BB i-bus KNX Operation Busch-priOn 6346/ Base Frame, 1-fold, Busch-priOn For Busch-priOn for seating and contact connection of rotary control elements, operating element 1-fold and 3-fold as well as the top/bottom finishing strip. For contacting with the Bus Coupler prion or Power Bus Coupler prion. unit 6346/ / Base Frame, 2-fold, Busch-priOn For Busch-priOn for seating and contact connection of 8.89 cm (3.5") TFT colour display with rotary control element, rotary control element 1-fold and 3-fold as well as the top/bottom finishing strip. For contacting with the Power Bus Coupler prion. unit 6346/ / Base Frame, 3-fold, Busch-priOn For Busch-priOn for seating and contact connection of 8.89 cm (3.5") TFT colour display with rotary control element, rotary control element 1-fold and 3-fold as well as the top/bottom finishing strip. For contacting with the Power Bus Coupler prion. unit 6346/ Control Element, 1-fold, Busch-priOn Freely programmable multi-function operation element for installation in the Base Frame 1-fold, 2-fold or 3-fold. Supports the KNX functions with innovative colour concept on the labelling symbols or standard lighting in red/green. The accompanying symbol can be substituted by other alternative labelling symbols. unit studio white, high gloss G white glass glass black stainless steel BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

76 BB i-bus KNX Operation Busch-priOn Control Element, 3-fold, Busch-priOn Freely programmable multi-function operation element for installation in the Base Frame 1-fold, 2-fold or 3-fold. Supports the KNX functions with innovative colour concept on the labelling symbols or standard lighting in red/green. The accompanying symbol can be substituted by other alternative labelling symbols. unit studio white, high gloss G white glass glass black stainless steel Rotary Control Element, 1-fold, Busch-priOn Freely programmable multi-function rotary control element for installation in the Base Frame 1-fold, 2-fold or 3-fold. Supports the KNX functions with innovative colour concept on the rotary knob or standard lighting in red/green. Rotary knob stainless steel. unit studio white, high gloss G white glass glass black stainless steel cm (3.5") TFT Colour Display with Rotary Control Element, Busch-priOn Freely programmable 8.89 cm (3.5") TFT colour display with rotary control element for installation in the Base Frame, 2-fold or 3-fold. For representation of up to 120 functions. With integrated weekly time switch, alarm, timer, with light scene function, screensaver and control of multimedia devices (in conjunction with additional device). Free function inscription with user-defined texts and symbols. Supports the KNX functions with innovative colour concept on the rotary knob. Rotary knob stainless steel. unit studio white, high gloss G white glass glass black stainless steel CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

77 BB i-bus KNX Operation Busch-priOn Busch Watchdog 180 FM Sensor, Busch-priOn Sends switching commands with motion detection in combination with the bus coupler Busch-priOn. Programmable via ETS for automatic and semi-automatic operation. unit studio white, high gloss G white glass glass black stainless steel Top End Strip, Busch-priOn For mounting on Base Frame 1-fold to 3-fold. unit studio white, high gloss G white glass glass black stainless steel Top End Strip with IR Receiver and Proximity Sensor, Busch-priOn For mounting on Base Frame 1-fold to 3-fold. With integrated IR receiver for control by IR handheld control as well as integrated proximity function. unit glass black Bottom End Strip without logo, Busch-priOn For mounting on Base Frame 1-fold to 3-fold. unit studio white, high gloss G white glass glass black stainless steel BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

78 BB i-bus KNX Operation Busch-priOn Bottom End Strip with Temperature Sensor, Busch-priOn For mounting on Base Frame 1-fold to 3-fold. Provides the value measured by the temperature sensor to the 8.89 cm (3.5") TFT colour display or the room thermostat. unit studio white, high gloss G white glass glass black stainless steel Top End Strip with Display, Room Thermostat, IR Receiver and Proximity Sensor, Busch-priOn In combination with control element 3-fold, Busch-priOn. With integrated room thermostat, display, proximity sensor and IR receiver. Room thermostat for heating and cooling (PI, PWM or 2-point) and control of up to 5-speed Fan Coil ctuators. Display for indication of 1 bit; 1, 2, 3, 4 or 14 byte values as text or symbols. unit glass black Inscription Symbols, Busch-priOn For Busch-priOn operating element 1-fold to 3-fold with different symbols. 6353/ unit lighting 6353/ blind 6353/ Room Temperature 6353/ scene 6353/ CDC F0b / CP-D 24/2.5 Commissioning Interface / dapter 6120/ and 6120/ via USB port or via SD card slot. With integrated battery for independent operation for up to 8 h. unit 6149/ Power Supply, 24 V, 2.5, MDRC For Busch-priOn Power Bus Coupler 6120/ unit CP-D 24/2.5 2CDG120037R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

79 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

80 BB i-bus KNX Operation Standard control elements 12 The standard control elements are available as 1/2gang, 2/4gang or 4/8gang models. Every switch rocker has two LEDs, which display the status of the connected loads. The separate switch rockers are freely programmable and are suitable for switching and dimming, and also for operating blinds and as a light scene extension unit. They can also be used in commercial applications. nti-theft protection has also been integrated an important factor for installations in public areas. Customised text. Pictograms can be applied to push buttons for easier orientation. clear text template with standard symbols is included for every sensor. The self-explanatory pictograms are available for the complete range of building control technology and if necessary can be easily replaced. If the appropriate symbol is not included, the push buttons can be labelled as desired. The related bus-coupler unit is included in delivery Function Switching Dimming Blinds Pushbutton Value transmitter Light scene extension unit Function Switching Dimming Blinds Pushbutton Value transmitter Light scene extension unit Function Switching Dimming Blinds Pushbutton Value transmitter Light scene extension unit 01 Standard control element 1/2gang 02 Standard control element 2/4gang 03 Standard control element 4/8gang Features Labellable switch rockers nti-theft protection Freely programmable switches Status/orientation light (red/green/off) Features Labellable switch rockers nti-theft protection Freely programmable switches Status/orientation light (red/green/off) Features Labellable switch rockers nti-theft protection Freely programmable switches Status/orientation light (red/green/off) 78 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

81 BB i-bus KNX Operation Standard control elements / / /01 Standard control element, 1-fold with bus coupler enclosed With labelling field. Transparent labelling sheet With 1 Control element: rocker switch left/right with standard symbols included in delivery. Display elements: Two LED per rocker via separate communication object for status (Red/Green/OFF) or orientation light. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 63 mm x 63 mm Standard control element, Standard control element, 2-fold with bus coupler enclosed 4-fold with bus coupler enclosed With 2 Control elements: rocker switch left/right With 4 Control elements: rocker switch left/right Pack unit pc. Description Type Order code Price E Type Order code Price E Type Order code Price E future linear 1 anthracite 6125/ / / savanne/ivory 6125/ / / aluminium silver 1) 6125/ / / davos/studio white 6125/ / / studio white, matt 1) 6125/ / / black, matt 1) 6125/ / / solo 1 savanne/ivory 6125/ / / davos/studio white 6125/ / / meteor/grey metallic 1) 6125/ / / sahara/yellow 6125/ / / carat 1 anthracite 6125/ / / savanne/ivory 6125/ / / davos/studio white 6125/ / / pure stainless steel 1) 1 pure stainless steel 6125/ / / Busch-axcent 1 davos/studio white 6125/ / / chalet-white 6125/ / / ) Surface painted BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

82 BB i-bus KNX Operation Multifunction control elements 12 The multifunction control elements with LED colour code concept meet the highest demands for comfort and technology. They each come with two RGB LEDs per rocker switch, which conform to a consistent colour concept. This makes the function obvious at a glance, and the surfaces can be additionally fitted with pictograms. Each side of a rocker switch can be occupied with its own function each for calling up one light scene, for instance. This turns a 4gang control element into an 8gang control element. Wide range. Different shapes, colours and materials fulfil every requirement. KNX control elements are available in the carat, pure stainless steel, solo, Busch-axcent and future linear programmes. The complete range of conventional switches from these series is available, so there are no limits to the options for combining KNX components Multifunction control element 1/2gang 02 Multifunction control element 2/4gang 03 Multifunction control element 4/8gang 04 Room temperature controller 05 Multifunction control element 2/4gang, integrated room thermostat 06 Multifunction control element 3/6gang with IR reception 07 FM movement detector standard 08 FM movement detector comfort Function Switching Dimming Blinds Pushbutton Value transmitter Light scene extension unit Step-type Multiple operation Logic function (including light scenes) Features Labellable switch rockers nti-theft protection Freely programmable switches LED colour code concept Function Switching Dimming Blinds Pushbutton Value transmitter Light scene extension unit Step-type Multiple operation Logic function (including light scenes) Features Labellable switch rockers nti-theft protection Freely programmable switches LED colour code concept Function Switching Dimming Blinds Pushbutton Value transmitter Light scene extension unit Step-type Multiple operation Logic function (including light scenes) Features Labellable switch rockers nti-theft protection Freely programmable switches LED colour code concept 80 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

83 BB i-bus KNX Operation Multifunction control elements Function Comfort Stand-by Night mode Frost protection Specified temperature Time Date Heating Cooling Fan Coil operation for heating and cooling Light scenes Light scene extension unit Value Logic function (including light scenes) Features Labellable switch rockers nti-theft protection Display illumination LED colour code concept Function Comfort Stand-by Night mode Frost protection Specified temperature Time Date Heating Cooling Fan Coil operation for heating and cooling Light scenes Light scene extension unit Value Logic function (including light scenes) Features Labellable switch rockers nti-theft protection Display illumination Colour concept Function 10 freely programmable IR channels Switching Dimming Blinds Button Light scenes Light scene extension unit Value Logic function (including light scenes) Features Labellable switch rockers ntitheft protection Display illumination Colour concept 08 Function 4 channels Logic function (including light scenes) BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

84 BB i-bus KNX Operation Multifunction control elements / / /02 For BCU 6120/ or 6120/ Control element, 1/2-fold With labelling field. Support of KNX functions Multi-function/colour concept through innovative colour concept or standard With 1 Control element: rocker switch left/right illumination red/green. Push switch function: switching/dimming/blind/sending values/scenes etc. Transparent labelling sheet with standard symbols included in delivery. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Display elements: Two LED per rocker via separate communication object for status (Red/Green/OFF) or orientation light. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 63 mm x 63 mm Control element, 2/4-fold Control element, 4/8-fold Multi-function/colour concept Multi-function/colour concept With 2 Control elements: rocker switch left/right With 4 Control elements: rocker switch left/right Pack unit pc. Description Type Order code Price E Type Order code Price E Type Order code Price E future linear 1 anthracite 6125/ / / savanne/ivory 6125/ / / aluminium silver 1) 6125/ / / davos/studio white 6125/ / / studio white, matt 1) 6125/ / / black, matt 1) 6125/ / / solo 1 savanne/ivory 6125/ / / davos/studio white 6125/ / / meteor/grey metallic 1) 6125/ / / sahara/yellow 1) 6125/ / / carat 1 anthracite 6125/ / / savanne/ivory 6125/ / / davos/studio white 6125/ / / pure stainless steel 1) 1 pure stainless steel 6125/ / / Busch-axcent 1 davos/studio white 6125/ / / chalet-white 6125/ / / ) Surface painted 82 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

85 BB i-bus KNX Operation Multifunction control elements 6129/01 Control Element, 3/6-fold, multifunction, with IR-Interface, FM suitable for KNX bus coupler 6120/ and 6120/ With IR interface for Buschremote controllers or / Push button function: switching/dimming/ blind/value sending/light scenes/step-type switch functions. Switch contacts left/right. Two freely programmable RGB LEDs per rocker. With RGB colour code concept or red/green/ OFF-operation. With labeling field. Transparent labeling sheet with standard symbols included in delivery. unit future linear anthracite 6129/ savanne/ivory 6129/ aluminium silver 1) 6129/ davos/studio white 6129/ studio white, matt 1) 6129/ black, matt 1) 6129/ solo savanne/ivory 6129/ davos/studio white 6129/ meteor/grey metallic 1) 6129/ sahara/yellow 6129/ carat anthracite 6129/ savanne/ivory 6129/ davos/studio white 6129/ pure stainless steel 1) pure stainless steel 6129/ Busch-axcent davos/studio white 6129/ chalet-white 6129/ ) Surface painted BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

86 BB i-bus KNX Operation Movement Detectors / /02 Movement detector with up to 4 channels. For BB i-bus KNX 6120/12-101, 6120/13. Busch-Watchdog 180 flush-mounted standard sensor Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.) Busch-Watchdog 180 flush-mounted comfort sensor II Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.) Pack Description Type Order code Price Type Order code Price unit pc. E E future linear 1 anthracite 6122/ / savanne/ivory 6122/ / aluminium silver 1) 6122/ / davos/studio white 6122/ / studio white, matt 1) 6122/ / black, matt 1) 6122/ / solo 1 savanne/ivory 6122/ / davos/studio white 6122/ / meteor/grey metallic 1) 6122/ / sahara/yellow 6122/ / carat 1 anthracite 6122/ / savanne/ivory 6122/ / davos/studio white 6122/ / pure stainless steel 1) 1 pure stainless steel 6122/ / Busch-axcent 1 davos/studio white 6122/ / chalet-white 6122/ / ) Surface painted 84 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

87 BB i-bus KNX Operation Room Thermostats / /01 suitable for KNX bus coupler 6120/ and 6120/ For heating and cooling (PI, PWM or 2-point). Constant room temperature controller for fan-coil applications (up to 5-speed level ventilation actuators in 2- and 4-pipe systems) and conventional heating and cooling systems. With manual and automatic adjustment of fan levels. Room Thermostat with Display, FM Switch contacts left/right to adjust set-points and operating mode manualy. Two freely programmable RGB LEDs per rocker. With RGB colour code concept or red/green/off-operation. LCD displaying operation mode, temperature, time and date. With labeling field. Transparent labeling sheet with standard symbols included in delivery. Room Thermostat with Display and 2/4-fold Switch Sensor, FM Push button function: switching/dimming/blind/value sending/light scenes/step-type switch functions. Switch contacts left/right. Two freely programmable RGB LEDs per rocker. With RGB colour code concept or red/green/off-operation. LCD displaying operation mode, temperature, time and date. With labeling field. Transparent labeling sheet with standard symbols included in delivery. Pack unit pc. Description Type Order code Price E Type Order code Price E future linear 1 anthracite 6124/ / savanne/ivory 6124/ / aluminium silver 1) 6124/ / davos/studio white 6124/ / studio white, matt 1) 6124/ / black, matt 1) 6124/ / solo 1 savanne/ivory 6124/ / davos/studio white 6124/ / meteor/grey metallic 1) 6124/ / sahara/yellow 6124/ / carat 1 anthracite 6124/ / savanne/ivory 6124/ / davos/studio white 6124/ / pure stainless steel 1) 1 pure stainless steel 6124/ / Busch-axcent 1 davos/studio white 6124/ / chalet-white 6124/ / ) Surface painted BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

88 BB i-bus KNX Operation Frames K Frames, future linear For vertical and horizontal installation. unit 1-fold, anthracite K fold, savanna/ivory K fold, aluminium silver 1) K fold, davos/studio white K fold, studio white, matt 1) K fold, black matt 1) K fold, anthracite K fold, savanna/ivory K fold, aluminium silver 1) K fold, davos/studio white K fold, studio white, matt 1) K fold, black matt 1) K fold, anthracite K fold, savanna/ivory K fold, aluminium silver 1) K fold, davos/studio white K fold, studio white, matt 1) K fold, black matt 1) K fold, anthracite K fold, savanna/ivory K fold, aluminium silver 1) K fold, davos/studio white K fold, studio white, matt 1) K fold, black matt 1) K fold, anthracite K fold, savanna/ivory K fold, aluminium silver 1) K fold, davos/studio white K fold, studio white, matt 1) K fold, black matt 1) K ) Surface painted 86 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

89 BB i-bus KNX Operation Frames Frames, solo For vertical and horizontal installation. unit 1-fold, chrome, matt fold, chrome, glossy G fold, davos/studio white fold, chrome, matt fold, chrome, glossy G fold, davos/studio white fold, chrome, matt fold, chrome, glossy G fold, davos/studio white fold, chrome, matt fold, chrome, glossy G fold, davos/studio white fold, chrome, matt fold, chrome, glossy G fold, davos/studio white Frames, carat For vertical and horizontal installation. unit 1-fold, white glass fold, bronze fold, gold 1) fold, glass black fold, chrome fold, stainless steel fold, white glass fold, bronze fold, gold 1) fold, glass black fold, chrome fold, stainless steel fold, white glass fold, bronze fold, gold 1) fold, glass black fold, chrome fold, stainless steel fold, white glass fold, bronze fold, gold 1) fold, glass black fold, chrome fold, stainless steel ) Gold plated 24 carat BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

90 BB i-bus KNX Operation Frames K Frames, pure stainless steel For vertical and horizontal installation. Stainless steel material. nti-fingerprint (does not leave any visible fingerprints on the material). unit 1-fold, stainless steel K fold, stainless steel K fold, stainless steel K fold, stainless steel K fold, stainless steel K Frames, axcent For vertical and horizontal installation. unit 1-fold, black fold, brown glass NEW fold, davos/studio white NEW fold, yellow NEW fold, green NEW fold, red NEW fold, blue NEW fold, white glass fold, entrée-grey NEW fold, château-black NEW fold, chalet-white NEW fold, foyer-red NEW fold, maison-beige NEW fold, black fold, brown glass NEW fold, davos/studio white NEW fold, yellow NEW fold, green NEW fold, red NEW fold, blue NEW fold, white glass fold, entrée-grey NEW fold, château-black NEW fold, chalet-white NEW fold, foyer-red NEW fold, maison-beige NEW Continuation of table Frames, axcent on next page 88 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

91 BB i-bus KNX Operation Frames Continuation of table Frames, axcent unit 3-fold, black fold, brown glass NEW fold, davos/studio white NEW fold, yellow NEW fold, green NEW fold, red NEW fold, blue NEW fold, white glass fold, entrée-grey NEW fold, château-black NEW fold, chalet-white NEW fold, foyer-red NEW fold, maison-beige NEW fold, black fold, brown glass NEW fold, davos/studio white NEW fold, yellow NEW fold, green NEW fold, red NEW fold, blue NEW fold, white glass fold, entrée-grey NEW fold, château-black NEW fold, chalet-white NEW fold, foyer-red NEW fold, maison-beige NEW fold, black fold, brown glass NEW fold, davos/studio white NEW fold, yellow NEW fold, green NEW fold, red NEW fold, blue NEW fold, white glass fold, entrée-grey NEW fold, château-black NEW fold, chalet-white NEW fold, foyer-red NEW fold, maison-beige NEW BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

92 BB i-bus KNX Operation Busch-triton 12 With freely programmable switch rockers, backlit label fields and IR sensor Busch-triton is ideal for any application and with its elegant design it is commonly installed in hotels and public areas. Busch-triton is equipped with an integrated bus coupler and IR receiver. The unit composed of control element and integrated bus coupler now really has everything required to control building systems elegantly and comfortably. Colour-coordinated. The Busch-triton is available in five stunning colours, offering exactly the right ambience for any environment. The colours offer exactly the right accent to the carat, impuls, alpha and future linear ranges such as the use of the colour-coordinated socket outlets or motion detectors /2gang control element with rear-illuminated labelling area and IR reception 02 3/6gang control element with rear-illuminated labelling area and IR reception 03 5/10gang control element with rear-illuminated labelling area and IR reception Function Switching Dimming Blinds Value transmitter Value dimming sensor Light scene extension unit Step-type switch Short/long operation 13 freely programmable IR channels 8 light scenes Features Labellable switch rockers Rearilluminated labelling field nti-theft protection Freely programmable switches IR remote-controllable Freely programmable additional key Function Switching Dimming Blinds Value transmitter Value dimming sensor Light scene extension unit Step-type switch Short/long operation 13 freely programmable IR channels 8 light scenes Features Labellable switch rockers Rearilluminated labelling field nti-theft protection Freely programmable switches IR remote-controllable Function Switching Dimming Blinds Value transmitter Value dimming sensor Light scene extension unit Step-type switch Short/long operation 13 freely programmable IR channels 8 light scenes Features Labellable switch rockers Rearilluminated labelling field nti-theft protection Freely programmable switches IR remote-controllable Freely programmable additional key 90 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

93 BB i-bus KNX Operation Busch-triton Function LCD display room temperature controller Comfort Stand-by Night operation Frost protection Heating Cooling Fan control Switching Dimming Blinds Value 13 freely programmable IR channels 8 light scenes Features Labellable switch rockers Rearilluminated labelling field nti-theft protection Freely programmable switches IR remote-controllable Freely programmable additional key Function LCD display room temperature controller Comfort Stand-by Night operation Frost protection Heating Cooling Fan control Switching Dimming Blinds Value 13 freely programmable IR channels 8 light scenes Features Labellable switch rockers Rearilluminated labelling field nti-theft protection Freely programmable switches IR remote-controllable Freely programmable additional key 01 3/6gang control element with rearilluminated labelling field, integrated room thermostat, LCD display and IR reception 02 5/10gang control element with rearilluminated labelling field, integrated room thermostat, LCD display and IR reception BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

94 BB i-bus KNX Operation Busch-triton /10-24G-500 Busch-triton Control Element, 1/2-fold, FM With intergrated bus coupling unit. With IR interface for Busch-remote controllers. Push button function: switching/dimming/blind/value sending/light scenes/step-type switch functions. Switch contacts left/right. One freely programmable LED per rocker (red/green/off). With labeling field. unit alpha platinum 6320/ studio white,high gloss 6320/10-24G palladium 6320/ impuls champagne metallic 6320/ future linear aluminium silver 6320/ /30-24G-500 Busch-triton Control Element, 3/6-fold, FM With intergrated bus coupling unit. With IR interface for Busch-remote controllers. Push button function: switching/dimming/blind/value sending/light scenes/step-type switch functions. Switch contacts left/right. One freely programmable LED per rocker (red/green/off). With labeling field. unit alpha platinum 6320/ studio white,high gloss 6320/30-24G palladium 6320/ impuls champagne metallic 6320/ future linear aluminium silver 6320/ CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

95 BB i-bus KNX Operation Busch-triton 6320/50-24G-500 Busch-triton Control Element, 5/10-fold, FM With intergrated bus coupling unit. With IR interface for Busch-remote controllers. Push button function: switching/dimming/blind/value sending/light scenes/step-type switch functions. Switch contacts left/right. One freely programmable LED per rocker (red/green/off). With labeling field. unit alpha platinum 6320/ studio white,high gloss 6320/50-24G palladium 6320/ impuls champagne metallic 6320/ future linear aluminium silver 6320/ /38-24G-500 Busch-triton Control Element with Room Thermostat and 3/6-fold Switch Sensor, FM With intergrated bus coupling unit. With IR interface for Busch-remote controllers. For heating and cooling (PI, PWM or 2-point). Constant room temperature controller for fan-coil applications (up to 5-speed level ventilation actuators in 2- and 4-pipe systems) and conventional heating and cooling systems. With manual and automatic adjustment of fan levels. Push button function: switching/ dimming/blind/value sending/light scenes/step-type switch functions. Switch contacts left/right. One freely programmable LED per rocker (red/green/off). LCD displaying operation mode and temperature. With labeling field. unit alpha platinum 6320/ studio white,high gloss 6320/38-24G palladium 6320/ impuls champagne metallic 6320/ future linear aluminium silver 6320/ BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

96 BB i-bus KNX Operation Busch-triton /58-24G-500 Busch-triton Control Element with Room Thermostat and 5/10-fold Switch Sensor, FM With intergrated bus coupling unit. With IR interface for Busch-remote controllers. For heating and cooling (PI, PWM or 2-point). Constant room temperature controller for fan-coil applications (up to 5-speed level ventilation actuators in 2- and 4-pipe systems) and conventional heating and cooling systems. With manual and automatic adjustment of fan levels. Push button function: switching/dimming/blind/value sending/light scenes/step-type switch functions. Switch contacts left/right. One freely programmable LED per rocker (red/green/off). LCD displaying operation mode and temperature. With labeling field. unit alpha platinum 6320/ studio white,high gloss 6320/58-24G palladium 6320/ impuls champagne metallic 6320/ future linear aluminium silver 6320/ Infra-Red Hand Held Transmitter For infra-red receiver and KNX flush-mounted infra-red interface. Switching and dimming of up to 10 consumers in 2 groups (1-5/6-10). Programming and selection of 2 MEMO memories per group is possible. Power supply: 4 alkaline manganese batteries, IEC LR03 (microcell) not included in scope of supply Detection range: frontal 15 m. unit CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

97 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

98 BB i-bus KNX Operation Push Button Coupling Unit 12 The push-button coupling unit with a centre position offers maximum flexibility. Installed in a flush-mounted wall box, it accepts switch rockers from conventional switch ranges* like a completely standard flush-mounted insert. Covers from all conventional ranges can now be used for KNX. This offers maximum freedom in the selection of the switch range and makes retrofitting easier Features Easy mounting and uncomplicated commissioning ll flush-mounted switch ranges* can be used for the BB i-bus KNX ffordable solution for renovations Status/orientation light (red/green/off) (only with 1gang push-button/switches) Integration in surface-mounted water protected units Push-button coupler 1/2gang with integrated bus coupler 02 Push-button coupler 2/4gang with integrated bus coupler 03 Push-button coupler 1/2gang for ocean with integrated bus coupler 04 Push-button coupler 2/4gang for ocean with integrated bus coupler Design without limits. The push-button coupling unit includes the complete range* of switches for KNX. Switch rockers from all switch ranges can now be converted to KNX push buttons, which not only switch on and off but also dim or show the status with an LED (6108/01 and 6108/04 only). 1gang and 2gang models for single and 2gang switch rockers are available. KNX water protected The push-button coupling unit also allows special products to be used for KNX. Special models for water-protected installation allow covers from, for example, the ocean surface-mounted range to be used. This means that KNX sensors can also be safely installed in a cellar, outside on a patio or in commercial applications. Temperature range: -25 C to 45 C *except impuls, basic55 and ll Weather 44 Busch Jaeger switch ranges only available for selected markets. For further information please contact your local BB office. 96 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

99 BB i-bus KNX Operation Push Button Coupling Unit KNX Switch Connection Unit, FM with intergrated bus coupling unit. With neutral position. Suitable for conventional switch rockers of the following Busch-Jaeger design ranges: Busch-Duro 2000 SI/SI Linear, Reflex SI/SI Linear, future linear, alpha, solo, Busch-axcent, carat and pure stainless steel*. One freely programmable red/green LED (only 6108/01-500) / unit 1/2-fold 6108/ /4-fold 6108/ / KNX Switch Connection Unit for design ocean (IP44), FM with intergrated bus coupling unit. For integration into SM-housing of ocean range*. unit 1/2-fold 6108/ /4-fold 6108/ *ll available switch rockers and additional information about Busch-Jaeger design ranges under BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

100 BB i-bus KNX Operation Room Temperature Controller / Room Temperature Controller, Commercial, FM Room temperature controller without local operation. With intergrated bus coupling unit. For heating and cooling. Constant room temperature controller for fan-coil applications (up to 5-speed level ventilation actuators in 2- and 4-pipe systems) and conventional heating and cooling systems. Suitable for cover plates 2114-xxx or 6541-xxx but not suitable for cover plates like , -21,-260 and unit 6108/ Cover Plate for Room Temperature Controller For room temperature controller, commercial. unit future linear anthracite savanna/ivory aluminium silver 1) davos/studio white studio white, matt 1) black matt 1) solo savanna/ivory davos/studio white meteor/grey metallic 1) sahara/yellow carat anthracite savanna/ivory davos/studio white pure stainless steel 1) pure stainless steel Busch-axcent davos/studio white chalet-white ) Surface painted 98 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

101 BB i-bus KNX Operation Room Temperature Controller Cover Plate for Temperature Controller, Commercial For room temperature controller, commercial. unit alpha ivory G studio white, matt studio white, high gloss G platinum 1) bronze 1) palladium 1) titanium 1) impuls alpine white champagne metallic ivory studio white matt 2) black matt 2) blackberry 2) aluminium silver 2) ) Real metal surface 2) Surface painted Cover Plate for Temperature Controller, Commercial For room temperature controller, commercial. unit Busch-Duro 2000 SI white (SI-Series) Reflex SI alpine white (SI-Series) BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

102 BB i-bus KNX Operation Millenium 12 The new Millenium collection is the first metal range to incorage the KNX system, the most intelligent way of managing spaces and optimizing performance in terms of energy savings. Millenium is based on a combinable concept which creates a very comprehensive range, suitable for any types of needs. This makes it the ideal collection for all types of homes, hotels, offices and shops. Wide range. Millenium range offers special mounting plates for KNX sensors to reduce the height and improve the aesthetics for ultra slim design. The KNX sensors allow to replace the buttons with desired symbols in order to adjust the sensors to specific design and needs like light, blind, scene, RTC or fan coil. Millenium offers a wide and elegant choice of finishes in stainless steel material: from the Brush Stainless Steel, to the soft new touch given by the Silk Black, and the luxury of the sophisticated gold finishes, Matt Gold and ntique Gold Switch Sensor 2gang KNX 02 Switch Sensor 4gang KNX 03 Switch Sensor 6gang KNX 04 Switch Sensor 6gang KNX with IR 05 Busch watchdog 180 KNX 06 Room Thermostat KNX Function Switching Dimming Blinds Sending values Scenes etc. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Control element: Switch contacts Display elements: LED to indicate the function Function Switching Dimming Blinds Sending values Scenes etc. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Control element: Switch contacts Display elements: LED to indicate the function Function Switching Dimming Blinds Sending values Scenes etc. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Control element: Switch contacts Display elements: LED to indicate the function 100 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

103 BB i-bus KNX Operation Millenium The Millenium range is only available in the following countries: China, Dubai, India, Kuweit, Oman, Qatar, Saudi rabia, Singapore, UE and UK. Frames and special mounting plates for KNX sensores have to ordered by: BB, S.. Low Voltage Products-Niessen, Oiartzun / Spain Function Switching Dimming Blinds Sending values Scenes etc. 6gang sensor with IR. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Control element: Switch contacts Display elements: LED to indicate the function Function Movement sensor with up to four channels. Detection range: frontal: 6 m, lateral: 6 m Detection angle: 180 Brightness limit value: 5 Lux Lux Mounting height: 1.1 m Function Control element with room thermostat function for triggering the heating, ventilation and fan-coil actuators. The controller is a thermostat for Fan Coil units in 2- and 4-pipe systems and conventional heating or cooling systems. The fan stage can be switched manually or in automatic mode. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Switch contacts for operating mode selection and dial for setpoint or fan speed adjustment. Display elements: LCD showing operation modes. Protection class (Device): IP 20 Temperature range (Device): 5 C to 45 C BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

104 BB i-bus KNX Operation Millenium / fold sensor Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Control element: Switch contacts. Display elements: LED to indicate the function. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 53 mm x 44 mm. unit MD72053-N 1 (6125/ ) 6126/ fold sensor Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Control element: Switch contacts. Display elements: LED to indicate the function. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 53 mm x 44 mm. unit MD74053-N 1 (6126/ ) 6129/ fold sensor Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Control element: Switch contacts. Display elements: LED to indicate the function. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 53 mm x 44 mm. unit MD76053-N 1 (6129/ ) 6129/ fold sensor with IR Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Control element: Switch contacts. Display elements: LED to indicate the function. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 53 mm x 44 mm. unit MD76153-N 1 (6129/ ) 102 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

105 BB i-bus KNX Operation Millenium 6122/ Watchdog 180 flush mounted Movement sensor with up to four channels. Detection range: frontal: 6 m, lateral: 6 m. Detection angle: 180. Brightness limit value: 5 Lux 150 Lux. Mounting height: 1.1 m Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 53 mm x 44 mm. Position for installation: vertical. unit MD70153-N 1 (6122/ ) / Room thermostat heating/cooling Fan Coil Control element with room thermostat function for triggering the heating, ventilation and fancoil actuators. The controller is a thermostat for Fan Coil units in 2- and 4-pipe systems and conventional heating or cooling systems. The fan stage can be switched manually or in automatic mode. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Switch contacts for operating mode selection and dial for setpoint or fan speed adjustment. Display elements: LCD showing operation modes. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 53 mm x 44 mm. unit MD70053-N (6124/ ) 1 Buttons with symbols Buttons with symbols for Millenium control covers 1 / 2-gang, 2 / 4-gang, 3 / 6-gang and 3 / 6-gang with infrared. unit Ceiling light symbol M50701-GR 10 (6123/20-500) Blinds symbol M50702-GR 10 (6123/21-500) Scene symbol M50703-GR 10 (6123/22-500) Temperature symbol M50704-GR 10 (6123/23-500) Light symbol M50705-GR 10 (6123/24-500) Fan Coil symbol M50706-GR (6123/26-500) 10 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

106 BB i-bus KNX Operation Millenium 12 Triple rocker / KNX frame 1 gang Frame includes metal mounting plate. Dimensions 86 x 86 mm. unit Stainless Steel MD5153-ST 1 Silk Black MD5153-SB 1 Matt Gold MD5153-MG 1 ntique Gold MD5153-G 1 Triple rocker / KNX frame 2 gang Frame includes metal mounting plate. Dimensions 86 x 147 mm. unit Stainless Steel MD5253-ST 1 Silk Black MD5253-SB 1 Matt Gold MD5253-MG 1 ntique Gold MD5253-G 1 MD5053 Special metal mounting plate for KNX sensors llows reduction height of KNX sensors to 1mm. Only for following items: MD72053-N, MD74053-N, MD76053-N, MD76153-N. unit Special metal mounting plate for KNX sensors 1 gang MD CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

107 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

108 BB i-bus KNX Operation Zenit 12 Zenit is based on a combinable concept which creates a very comprehensive range, suitable for any type of needs. Optimizing comfort, safety and efficiency of homes and buildings: Providing with complete comfort solutions to satisfy all type of needs and projects. Ensuring safety and protection of persons and goods. Saving energy by using only the amount of energy required. Zenit offers two different mounting plates for KNX sensors corresponding to different market standards: VDE and NEM Switch Sensor 2gang KNX 02 Switch Sensor 4gang KNX 03 Switch Sensor 6gang KNX 04 Switch Sensor 6gang KNX with IR 05 Busch watchdog 180 KNX 06 Room Thermostat KNX Function Switching Dimming Blinds Sending values Scenes etc. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Control element: Switch contacts Display elements: LED to indicate the function Function Switching Dimming Blinds Sending values Scenes etc. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Control element: Switch contacts Display elements: LED to indicate the function Function Switching Dimming Blinds Sending values Scenes etc. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Control element: Switch contacts Display elements: LED to indicate the function 106 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

109 BB i-bus KNX Operation Zenit The Zenit VDE range is only available in the following countries: Spain, Portugal, Russia, France The Zenit NEM range is only available in the following countries: Latin merica, ustralia, Thailand, Vietnam. Sensors, frames and special mounting plates for KNX sensores have to ordered by: BB, S.. Low Voltage Products-Niessen, Oiartzun / Spain Function Switching Dimming Blinds Sending values Scenes etc. 6gang sensor with IR. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Control element: Switch contacts Display elements: LED to indicate the function Function Movement sensor with up to four channels. Detection range: frontal: 6 m, lateral: 6 m Detection angle: 180 Brightness limit value: 5 Lux Lux Mounting height: 1.1 m Function Control element with room thermostat function for triggering the heating, ventilation and fan-coil actuators. The controller is a thermostat for Fan Coil units in 2- and 4-pipe systems and conventional heating or cooling systems. The fan stage can be switched manually or in automatic mode. Features Incl. 10 logic channels (light scene actuator sequence actuator logic gates, etc.) Switch contacts for operating mode selection and dial for setpoint or fan speed adjustment. Display elements: LCD showing operation modes. Protection class (Device): IP 20 Temperature range (Device): 5 C to 45 C BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

110 BB i-bus KNX Operation Zenit 12 1/2-Fold sensor NEW Push switch function: switching / dimming / blind / sending values / scenes etc. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Control element: Switch contacts. Display elements: LED to indicate the function. 6125/ unit 6125/ N Cover Zenit 1/2 fold Cover Zenit 1/2 fold. vailable in white (BL), antrachite (N) and silver (PL). unit Cover Zenit 1/2 fold white N BL 2CL0N Cover Zenit 1/2 fold antrachite N N 2CL0N Cover Zenit 1/2 fold silver N PL 2CL0N NEW 2/4 -Fold sensor NEW Push switch function: switching / dimming / blind / sending values / scenes etc. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Control element: Switch contacts. Display elements: LED to indicate the function. 6126/ unit 6126/ N Cover Zenit 2/4 fold Cover Zenit 2/4 fold. vailable in white (BL), antrachite (N) and silver (PL). unit Cover Zenit 2/4 fold white N BL 2CL0N Cover Zenit 2/4 fold antrachite N N 2CL0N Cover Zenit 2/4 fold silver N PL 2CL0N NEW 108 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

111 BB i-bus KNX Operation Zenit 6129/ /6 -Fold sensor NEW Push switch function: switching / dimming / blind / sending values / scenes etc. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.) Control element: Switch contacts. Display elements: LED to indicate the function. Protection class (Device): IP 20. Temperature range (Device): 5 C to 45 C. Dimensions: (L x W x D): 44 mm x 44 mm. unit 6129/ N Cover Zenit 3/6 fold Cover Zenit 3/6 fold. vailable in white (BL), antrachite (N) and silver (PL). unit Cover Zenit 3/6 fold white N BL 2CL0N Cover Zenit 3/6 fold antrachite N N 2CL0N Cover Zenit 3/6 fold silver N PL 2CL0N NEW 6129/ /6 -Fold sensor with IR NEW Push switch function: switching / dimming / blind / sending values / scenes etc. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). With infrared. Control element: Switch contacts. Display elements: LED to indicate the function. unit 6129/ N Cover Zenit 3/6 fold with IR Cover Zenit 3/6 fold with IR. vailable in white (BL), antrachite (N) and silver (PL). unit Cover Zenit 3/6 fold N BL 2CL0N with IR white Cover Zenit 3/6 fold N N 2CL0N with IR antrachite Cover Zenit 3/6 fold N PL 2CL0N with IR silver NEW BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

112 BB i-bus KNX Operation Zenit / Room thermostat heating / cooling Fan Coil NEW Control element with room thermostat function for triggering the heating, ventilation and fancoil actuators. The controller is a thermostat for Fan Coil units in 2 - and 4-pipe systems and conventional heating or cooling systems. The fan stage can be switched manually or in automatic mode. Incl. 10 logic channels (light scene actuator, sequence actuator, logic gates, etc.). Switch contacts for operating mode selection and dial for setpoint or fan speed adjustment. Display elements: LCD showing operation modes. unit 6124/ N Cover Zenit room thermostat Cover Zenit room thermostat. vailable in white (BL), antrachite (N) and silver (PL). unit Cover Zenit RTC white N BL 2CL0N Cover Zenit RTC antrachite N N 2CL0N Cover Zenit RTC silver N PL 2CL0N NEW 6122/ Watchdog 180 flush mounted. NEW Movement sensor with up to four channels. Detection range: frontal: 6 m, lateral: 6 m. Detection angle: 180. Brightness limit value: 5 Lux 150 Lux. Mounting height: 1.1 m. unit 6122/ N Cover Zenit watchdog Cover Zenit watchdog. vailable in white (BL), antrachite (N) and silver (PL). unit Cover Zenit Watchdog N BL 2CL0N white Cover Zenit Watchdog N N 2CL0N antrachite Cover Zenit Watchdog N PL 2CL0N silver NEW 110 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

113 BB i-bus KNX Operation Zenit Buttons with symbols Buttons with symbols for Zenit control covers 1 / 2-gang, 2 / 4-gang, 3 / 6-gang and 3 / 6-gang with infrared. unit Ceiling light symbol 6123/ Blinds symbol 6123/ Scene symbol 6123/ Temperature symbol 6123/ Light symbol 6123/ Fan Coil symbol 6123/ NEW 12 Frames, Zenit VDE unit NEW N2271 XX 1 fold, vailable in N, BL, CB, CN, CV, OX, PL, PZ, WG* N2271 XX 1 fold basic (without logo), vailable in N, BL, CV, PL* N XX 2 fold, vailable in N, BL, CB, CN, CV, OX, PL, PZ, WG* N2272 XX 2 fold basic (without logo), vailable in N, BL, CV,PL* N XX 3 fold, vailable in N, BL, CB, CN, CV, OX, PL, PZ, WG* N2273 XX 3 fold basic (without logo), vailable in N, BL, CV,PL* N XX 4 fold, vailable in N, BL, CB, CN, CV, OX, PL, PZ, WG* N2274 XX 4 fold basic (without logo), vailable in N, BL, CV,PL* N XX Metal mounting plate Metal mounting plate for Zenit VDE KNX sensors. unit Metal mounting plate N NEW N * N = ntrachite, BL = white, CB = white glass, CN = black glass, CV = Cava, OX = Stainless Steel, PL = Silver, PZ = Slate, WG = Wenge BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

114 BB i-bus KNX Operation Zenit 12 Frame, Zenit NEM Dimensions (L x W): 122 x 90 mm. vailable in N, BL, CB, CN, CV, OX, PL, PZ, WG*. unit 1 fold N XX NEW N XX Metal mounting plate Metal mounting plate for Zenit NEM KNX sensors. Dimensions (L x W): 102 x 74 mm. unit Metal mounting plate N2371.9V 20 NEW N2371.9V * N = ntrachite, BL = white, CB = white glass, CN = black glass, CV = Cava, OX = Stainless Steel, PL = Silver, PZ = Slate, WG = Wenge 112 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

115 BB i-bus KNX Energy measurement BB offers various solutions for decentral energy measurement on the basis of the KNX standard. 13 Information (KNX) Energie Version 1 Information (KNX) Energie Electronic energy meters make the current energy values available on the KNX bus system in conjunction with a KNX interface. The measured data can be intermediately stored, evaluated and visualized from here. + + Version 2 Information (KNX) Energie The Energy Module can record the energy consumption for the individual devices. It is used particularly when upgrading existing KNX systems and wherever energy measurement is required without switch functions. It facilitates a detailed and transparent insight into the energy consumption of a building. The current meter values can be sent and evaluated. + + Schaltaktor Energiemodul Version 3 Information (KNX) Energie The Energy ctuator facilitates control of the connected consumer loads via the BB i-bus KNX. For each of the three switch channels, the individual consumption can be measured in the same way as for the Energy Module. For every channel, the proven functionality of the BB i-bus KNX Switch ctuators are available. + + Information (KNX) Intermediate meter for electrical energy Electrical consumer (load) Energy meter Energie BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

116 BB i-bus KNX Energy measurement 13 SE/S Energy ctuator, 3-fold, 16/20 X, MDRC Records the energy consumption of the connected electrical loads in the load circuit. Various electrical variables can be monitored and load peaks can be limited by simple load control. The 3 output channels can be manually operated and display the current switching state. The Energy ctuator can switch resistive, inductive and capacitive loads The switching capacity corresponds to the S/S X unit 4 SE/S CDG110136R EM/S Energy Module, MDRC Measures energy consumption and various electrical parameters in the terminal current. ctive power, Current, Voltage and Frequency can be monitored via threshold values and peak loads can be limited through a simple load control. The measured values are provided via BB i-bus KNX. unit 4 EM/S CDG110148R Meter Interface Module, MDRC It records consumption and measured values of the electrical energy consumption meters. Using an infra-red interface, the BB energy meter types of the - and B-series are incorporated. The information and data which is read can be used, for example, for cost centre accounting, energy optimisation, monitoring of installations and visualisation. ZS/S 1.1 The following values are available (depending on the meter type): Meter reading ctive energy Reactive energy Power values ctive power Reactive power pparent power Phase angle power Power factor Instrument values Voltages Tariff 1-4, total Tariff 1-4, total L1, L2, L3, total L1, L2, L3, total L1, L2, L3, total L1, L2, L3, total L1, L2, L3, total L1-N, L2-N, L3-N, L1-L2, L2-L3, L1-L3 Currents Phase angle voltage Phase angle current Quadrant Mains frequency Other Transformer ratio Power failures Tariffs Status information Communication monitoring Intermediate meter L1, L2, L3, N L1, L2, L3, total L1, L2, L3, total L1, L2, L3, total Read CT and VT Send and delete Read and changeover Send and read Read and reset unit ZS/S 1.1 2CDG110083R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

117 Electricity Meters Introduction Modular DIN rail products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail mounted electricity meters are designed for high level performance and are safe and fast to install. The DIN rail mounted electricity meters are available in several models: the new EQ meters C11, B21, 41 and 42 for single phase metering, the new EQ meters C13, B23, B24, 43 and 44 for three phase metering. BB Low Voltage Products The Low Voltage Products division manufactures low voltage circuit breakers, switches, control products, wiring accessories, enclosures and cable systems to protect people, installations and electronic equipment from electrical overload. The division further makes KNX systems that integrate and automate a building s electrical installations, ventilation systems, and security and data communication networks. ll these products help customers to save energy, improve productivity and increase safety. Global business The Low Voltage Products division is a global business producing mainly low-voltage electrical equipment that is sold to wholesalers, original equipment manufacturers as well as system integrators, and has moderate service requirements. BB s broad program of standardized products and components are the building blocks of system solutions, incorporating functionalities that will allow seamless integration in real time automation and information systems. t the product level, all the low voltage products can operate together perfectly. To create a system solution, every product is equipped with the tools necessary to install, operate and maintain it efficiently throughout the product life cycle. The range of low voltage products is supported by technical documentation. This together with compact design makes it easier than ever to incorporate our products in your system. Our customers can find all product related documentation such as brochures, catalogues, selection program, certificates, drawings and other information directly at 13 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

118 Electricity Meters Selection Guide 13 How do I select the best meter for my application? There are many versions of EQ meters in order to meet your requests. The EQ program comprises meters with different functionalities such as tariffs, communication interfaces or advanced clock functions. Spend a little time to evaluate the functions and imagine how they could add extra value to your metering. For example, the input counter (from silver level) on an EQ meter can be used to count products produced by a machine and be read out together with the energy consumption of the same machine. In one easy go you can allocate energy to any produced product from one source. nother useful function is previous values (from gold level). If you charge users in intervals the meter can secure the data even in the event of a broken communication link. You can collect the correct interval data later and also make it visible for your counterpart immediately on the meters display in case of any discussions. Make the meter an asset. Take the step from passive meter reading to an active user of the data you can retrieve. The meter can be an important asset for you in order to avoid costs like penalties or extra charge for reactive energy (from bronze level). Keep track of your maximum demand and reduce them to avoid charges. EQ meters can tell you the value of the maximum demand and also when it occurred. Harmonics is the source of many problems for all sorts of equipment connected to the low voltage network. Use an EQ meter (platinum level) to measure the THD and isolate the source before you have to take the cost and consequences of poor power quality Function Single phase Three phase C11 B C13 B23 B Direct connected Transformer connected element metering 3 element metering ccuracy 1%, Class 1, Class B ccuracy 0,5%, Class 0,5 S, Class C ctive energy Reactive energy pparent energy Import/Export energy Tariff registers, Instrument values 1 larm function 1 Harmonics, THD and no Previous values - day, week, month Max and min demand Load profiles - 8 channels Pulse output 1 I/O board - 2 in, 2 out Configurable I/O - 4 I/O channels Tariffs controlled by input Tariffs controlled by communication Tariffs controlled by clock MID approved, verified optional optional IEC approved Communication - Infrared (M-Bus) Communication - M-Bus optional optional optional optional optional optional optional Communication - RS-485 Modbus optional optional optional optional optional optional optional Communication - RS-485 EQ bus optional optional optional optional optional optional optional 1 = Steel 2 = Bronze 3 = Silver 4 = Gold 5 = Platinum = Not available Optional = vailable on some order codes 116 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

119 Electricity Meters Selection Guide Connection of EQ meters There are both one phase and three phase meters in the program. When the current exceeds the maximum current for a direct connected meter, a meter can be used from or B series with current transformers (CT s). If the voltage is outside the specification of the meter you can use an series meter with voltage transformers (VT s). Please note that three phase meters in and B series can be configured to be used in three or four wire applications. 13 C, B and series Single phase Three phase C11 B C13 B23 B Connection Direct Direct Direct CTVT Direct Direct CT Direct CTVT Max mp * ) * ) 80 6* ) Communication - IR, M-Bus, RS-485 IR, M-Bus, RS-485 IR, M-Bus, RS IR, M-Bus, RS-485 IR, M-Bus, RS-485 IR, M-Bus, RS-485 IR, M-Bus, RS-485 Functionality = Steel 2 = Bronze 3 = Silver 4 = Gold 5 = Platinum - = Not available Optional = vailable on some order codes * ) 6 is the secondary current of a connected current transformer used in cases with currents exceeding the max current for direct connected meters. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

120 Electricity Meters Series Product brief 13 Key applications pplications in industry pplications in commercial buildings Object metering Billing applications Meter performance Three phase and single phase Direct connected up to 80 Transformer connected 1, 2 or 5 ctive or active and reactive energy ccuracy class C, B or (Cl. 0,5 S, 1 or 2) Import or import and export measurement of energy Wide voltage range ( V) Pixel-oriented display Up to 4 tariffs Up to 4 inputs and outputs Low power consumption Optional clock functionality with tariff control, previous values, max/min demand, load profiles Harmonics measurement up to 16th harmonic and THD evaluation Communication Pulse output Built-in M-Bus Built-in RS-485 for Modbus RTU and EQ bus IR port for Serial Communication dapters Installation Terminal according to DIN ( Utility terminal ) Wide temperature range Sealable push buttons for configuration pprovals MID type approval annex B MID initial verification annex D IEC type approval 118 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

121 Electricity Meters Series Description The series EQ meters are meters for single phase and three phase metering. The series meters are mounted on a DIN rail and are suitable for installation in distribution boards and small enclosures such as consumer units. With the main terminals in accordance with DIN and accessible from the below the meters, the series is suitable for many applications. 13 General features The series meters are ideal for many applications and installations. The meters support a wide voltage range as well as a wide temperature range. The display is pixel-oriented and can display up to four quantities at the same time. Navigating the meter is easily done via the push-buttons below the display. To configure the meter settings, the set button must be accessed and this button is protected against unauthorized use when the glass lid on the front of the meter is closed and sealed. The power consumption of the meter is very low, less than 0.8 V. Communication Data from the series meters can be collected via pulse output or serial communication. The pulse output is a solid state relay that generates pulses proportionally to the measured energy. The meters can also be equipped with built-in serial communication interfaces for M-Bus or Modbus RTU (RS- 485). Meters with RS-485 interface can also be set to communicate over the new EQ bus with the new gateway G13. ll meters in the series come with an infrared port for communication with an external Serial Communication dapter (SC) such as the KNX adapter. Instrumentation The series meters support reading of instrument values. large number of electrical properties can be read. Depending on version of the meter the following data is available: ctive power pparent power Reactive power Current Voltage Frequency Power factor Harmonics Total harmonic distortion Inputs and outputs The series support up to four I/O s. It can be two inputs and two outputs in a fixed configuration or four I/O points that are freely configured to input or output. Inputs can be used for counting pulses from e.g. a water meter, or reading status from external devices. Outputs can be used as pulse outputs or controlling external apparatus like a contactor or an alarm (connected via an external relay). Outputs need an external voltage supply. pprovals The series meters are type approved according to IEC and they are both type approved and verified according to MID. MID is the Measuring Instruments Directive 2004/22/EC from the European Commission. MID type approval and verification is mandatory for meters in billing applications within EU and EE. The type approval is according to standards that covers all relevant technical aspects of the meter. These include climate conditions, electromagnetic compatibility (EMC), electrical requirements, mechanical requirements and accuracy. Tariffs The tariffs are controlled via inputs, via communication or via an internal clock. Event log Gold and Platinum meters have an event log function. The event log will log overvoltage, undervoltage, phase voltage outage, negative power, total power outage and presence of harmonics. Optional functionality series meters with a functionality level of Gold or Platinum have an internal clock for advanced functionality. The clock functions are briefly presented below. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

122 Electricity Meters Series Description 13 Internal clock The internal clock, sometimes called real time clock or RTC, has a built-in calendar and automatically keeps track of leap year and daylight savings time (DST). The DST function is optional. Backup of the clock during a power failure is provided by a supercapacitor. The time is controlled by a quartz crystal based clock. Time and date is set via push buttons or via communication. The internal clock is approved according to IEC and IEC These standards specify the requirements for time switches in electricity meter related products. The accuracy is better than 5 ppm at room temperature. Previous values The previous value feature is available on Gold and Platinum meters and will store all energy registers and input counter values together with a date/time stamp upon change of day, week or month. ll total values are stored and in meters equipped with the tariff feature all the tariff registers will also be stored. Maximum and minimum demand The demand function is available on Gold and Platinum meters. In the demand function, the mean power in each interval is measured and the maximum and minimum mean values are stored together with a date/time stamp. For each set of demand values the end date/time of the period is stored. The quantities that can be stored for each interval are active, reactive and apparent power (imported power only), and the number of pulses registered on inputs. Load profile The load profile function is available on the Platinum meters. The load profile stores the energy consumption at pre-defined intervals. The quantities that can be stored for each interval are active and reactive energy, both imported and exported energy, and the number of pulses registered on inputs. The load profile function uses the standard time setting irrespective if the daylight savings time function is activated or not. THD The THD and harmonics measurement is available on the Platinum meters. The voltage and current harmonics (2-16) together with the fundamental is measured sequentially one at a time. The total harmonic distortion is evaluated and displayed in percent. The separate harmonic frequencies measured are multiples of the fundamental frequency up to the 16th harmonic. THD data as well as individual harmonics are shown on the display. THD data and data for individual harmonics can also be read out via serial communication CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

123 Electricity Meters 41 Single phase meter 80, 4 DIN with IR port Description Direct connected electricity meter. Verified and approved according to MID. IEC approval. Instrument values. larm function. Communication - Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus CMC484003F0001 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty 1 pc Steel ctive energy V C Class B (Cl. 1) Pulse output CM170554R RS CM170500R M-Bus CM100240R Bronze ctive and reactive energy, import/export V C Class B (Cl. 1) Reactive Cl. 2 Pulse output RS CM170501R Silver ctive and reactive energy, import/export, tariffs 1-4, tariff control via inputs and communication V C Class B (Cl. 1) 2 output, 2 input CM170502R Reactive Cl. 2 RS CM170503R M-Bus CM170504R Gold ctive and reactive energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values, max and min demand V C Class B (Cl. 1) 2 output, 2 input RS CM170505R Reactive Cl. 2 M-Bus CM170506R Platinum ctive and reactive energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values, max and min demand, advanced load profiles, harmonics and THD V C Class B (Cl. 1) Reactive Cl. 2 Configurable 4 I/O channels RS CM100237R M-Bus CM170508R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

124 Electricity Meters 42 Single phase meter 6, 4 DIN with IR port 13 Description Transformer CTVT connected electricity meter. Verified and approved according to MID. IEC approval. Voltage V V C. Instrument values. larm function. Communication - Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus. 42 2CMC484005F0001 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty 1 pc Steel ctive energy V C Class B (Cl. 1) Pulse output CM170555R RS CM170510R M-Bus CM100242R Bronze ctive and reactive energy, import/export V C Class B (Cl. 1) Reactive Cl. 2 Pulse output RS CM170511R Silver ctive and reactive energy, import/export, tariffs 1-4, tariff control via inputs and communication V C Class B (Cl. 1) Reactive Cl. 2 2 output, 2 input RS CM170512R Gold ctive and reactive energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values, max and min demand V C Class B (Cl. 1) 2 output, 2 input RS CM170513R Reactive Cl. 2 M-Bus CM170514R Platinum ctive and reactive energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values, max and min demand, advanced load profiles, harmonics and THD V C Class C (Cl. 0,5 S) Reactive Cl. 2 Configurable 4 I/O channels RS CM100238R M-Bus CM170516R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

125 Electricity Meters 43 Three phase meter 80, 7 DIN with IR port Description Direct connected electricity meter. Verified and approved according to MID. IEC approval. 2- and 3-element metering. Instrument values. larm function. Communication - Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus CMC484004F0001 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty 1 pc Steel ctive energy 3 x 57.7/ /500 V C Class B (Cl. 1) Pulse output CM170520R RS CM100244R M-Bus CM100245R Class (Cl. 2) CM170521R Bronze ctive and reactive energy, import/export. 3 x 57.7/ /500 V C Class B (Cl. 1) Reactive Cl. 2 Pulse output CM100012R RS CM170522R M-Bus CM170523R Silver ctive and reactive energy, import/export, tariffs 1-4, tariff control via inputs and communication. 3 x 57.7/ /500 V C Class B (Cl. 1) Reactive Cl. 2 2 output, 2 input CM170524R RS CM170525R M-Bus CM170526R Gold ctive and reactive energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values, max and min demand. 3 x 57.7/ /500 V C Class B (Cl. 1) Reactive Cl. 2 2 output, 2 input RS CM170528R M-Bus CM170529R Platinum ctive and reactive energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values, max and min demand, advanced load profiles, harmonics and THD. 3 x57.7/ /500 V C Class B (Cl. 1) Reactive Cl. 2 Configurable 4 I/O channels CM100143R RS CM170531R M-Bus CM170532R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

126 Electricity Meters 44 Three phase meter 6, 7 DIN with IR port 13 Description Transformer CTVT connected electricity meter. Verified and approved according to MID. IEC approval. 2- and 3-element metering. Instrument values. larm function. Communication - Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus. 44 2CMC484006F0001 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty 1 pc Steel ctive energy 3 x 57.7/ /500 V C Class B (Cl. 1) Pulse output CM170533R Bronze ctive and reactive energy, import/export. 3 x 57.7/ /500 V C Class B (Cl. 1) Reactive Cl. 2 RS CM100248R M-Bus CM100249R Pulse output CM100013R RS CM170534R M-Bus CM170535R Silver ctive and reactive energy, import/export, tariffs 1-4, tariff control via inputs and communication. 3 x 57.7/ /500 V C Class B (Cl. 1) Reactive Cl. 2 Class C (Cl. 0,5 S) Reactive Cl. 2 2 output, 2 input CM170536R RS CM170537R M-Bus CM170538R Gold ctive and reactive energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values, max and min demand. 3 x 57.7/ /500 V C Class C (Cl. 0,5 S) Reactive Cl. 2 2 output, 2 input RS CM170540R M-Bus CM170541R Platinum ctive and reactive energy, import/export, tariffs 1-4, tariff controlled via inputs, communication or clock, previous values, max and min demand, advanced load profiles, harmonics and THD. 3 x 57.7/ /500 V C Class C (Cl. 0,5 S) Reactive Cl. 2 Configurable 4 I/O channels RS CM170545R M-Bus CM170546R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

127 Electricity Meters series Technical data (0.001 W) per phase at Voltage/current inputs Nominal voltage 230 V C 3x230/400 V C Voltage range V C (-20% - +15%) 3x57.7/ /500 V C (-20% - +15%) Power dissipation voltage circuits 0.8 V (0.8 W) total Power dissipation current circuits V (0.007 W) at 230 VC V (0.001 W) at 230 VC V (0.007 W) per phase at V and I b and I n 230 VC and I b 230 VC and I n Base current I b 5 5 Rated current I n 1 1 Reference current I ref 5 5 Transitional current I tr Maximum current I max Minimum current I min Starting current I st < 20 m < 1 m < 20 m < 1 m Terminal wire area 1-25 mm mm mm mm 2 Recommended tightening torque 3 Nm 1.5 Nm 3 Nm 1.5 Nm Communication Terminal wire area mm mm 2 Recommended tightening torque 0.25 Nm Transformer ratios Configurable voltage ratio (VT) 1/ /1 1/ /1 Configurable current ratio (CT) 1/9-9999/1 1/9-9999/1 Pulse indicator (LED) Pulse frequency 1000 imp/kwh 5000 imp/kwh 1000 imp/kwh 5000 imp/kwh Pulse length 40 ms 40 ms 40 ms 40 ms General data Frequency 50 or 60 Hz ± 5% ccuracy Class B (Cl.1) or Reactive Cl. 2 B (Cl.1), C (Cl. 0,5 S) or Reactive (Cl.2), B (Cl.1) or Reactive Cl. 2 B (Cl.1), C (Cl. 0,5 S) or Reactive Cl. 2 Cl. 2 ctive energy 1% 0.5%, 1% 1%, 2% 0.5%, 1% Display of energy Pixel oriented Environmental Operating temperature 40 C C Storage temperature 40 C C Humidity 75% yearly average, 95% on 30 days/year Resistance to fire and heat Terminal 960 C, cover 650 C (IEC ) Resistance to water and dust IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC Mechanical environment Class M1 in accordance with the Measuring Instrument Directive (MID). (2004/22/EC). Electromagnetic environment Class E2 in accordance with the Measuring Instrument Directive (MID), (2004/22/EC). Outputs Current m Voltage V C/DC. For meters with only 1 output, 5-40 V DC. Pulse output frequency Programmable: imp/kwh Pulse length Programmable: ms Terminal wire area mm 2 Recommended tightening torque 0.25 Nm Inputs Voltage V C/DC OFF 0-12 V C/DC ON V C/ V DC Min. pulse length 30 ms Terminal wire area mm 2 Recommended tightening torque 0.25 Nm EMC compatibility Impulse voltage test 6 kv 1.2/50 µs (IEC ) Surge voltage test 4 kv 1.2/50 µs (IEC ) Fast transient burst test 4 kv (IEC ) Immunity to electromagnetic HF-fields 80 MHz - 2 GHz at 10 V/m (IEC ) Immunity to conducted disturbance 150 khz - 80 MHz, (IEC ) Immunity to disturbance with 2kHz - 150kHz harmonics Radio frequency emission EN 55022, class B (CISPR22) Electrostatic discharge 15 kv (IEC ) Standards IEC , IEC class 1 & 2, IEC class 0,5 S, IEC class 2, IEC , GB/T , GBT class 1 & 2, GB/T class 0,5 S, GB , EN , EN category, B & C Mechanical Material Polycarbonate in transparent front glass, bottom case, upper case and terminal cover, Glass reinforced polycarbonate in terminal block. Dimensions Width 70 mm 123 mm Height 97 mm 97 mm Depth 65 mm 65 mm DIN modules 4 7 *) Only and BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

128 Electricity Meters B series Product brief 13 Key applications pplications in commercial buildings Object metering Meter performance Single phase and three phase Direct connected up to 65 ctive or active and reactive energy Import or import and export of energy ccuracy class B (Cl. 1) or C (Cl. 0,5 S) Low power consumption Transformer connected 1, 2 or 5 Up to 4 tariffs larm function Installation Wide temperature range Easy configuration pprovals MID type approval annex B MID initial verification annex D IEC type approval Communication Pulse output IR port for serial communication adapter Built-in M-Bus Built-in RS-485 for Modbus RTU or EQ bus 126 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

129 Electricity Meters B series Description The B series EQ meters are meters for single phase and three phase metering. The B series meters are mounted on a DIN rail and are suitable for installation in distribution boards and small enclosures such as consumer units. The B series are suitable in applications where there is a need for reliable energy measurements and where space is limited. 13 General features The B series meters are high runner meters for many applications and installations. Navigating the meter is easily done via the push-buttons below the display. To configure the meter settings, the set button must be accessed and this button is protected against unauthorized use when the glass lid on the front of the meter is closed and sealed. The power consumption of the meter is very low, less than 0.8 V. Communication Data from the B series meters can be collected via pulse output or serial communication. The pulse output is a solid state relay that generates pulses proportionally to the measured energy. The meters can also be equipped with built-in serial communication interfaces for M-Bus or Modbus RTU (RS-485). Meters with RS-485 interface can also be set to communicate over the new EQ bus with the new gateway G13. ll meters in the B series come with an infrared port for communication with an external Serial Communication dapter (SC) such as the KNX adapter. Instrumentation The B series meters support reading of instrument values. large number of electrical properties can be read. Depending on version of the meter the following data is available: ctive power pparent power Reactive power Current Voltage Frequency Power factor Inputs and outputs The B series support two inputs and two outputs in a fixed configuration. Inputs can be used for counting pulses from e.g. a water meter, or reading status from external devices. Outputs can be used as pulse outputs or controlling external apparatus like a contactor or an alarm (connected via an external relay). pprovals The B series meters are type approved according to IEC and they are both type approved and verified according to MID. MID is the Measuring Instruments Directive 2004/22/EC from the European Commission. MID type approval and verification is mandatory for meters in billing applications within EU and EE. The type approval is according to standards that covers all relevant technical aspects of the meter. These include climate conditions, electromagnetic compatibility (EMC), electrical requirements, mechanical requirements and accuracy. Tariffs The tariffs are controlled via inputs or communication. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

130 Electricity Meters B21 Single phase meter 65, 2 DIN with IR port 13 Description Direct connected electricity meter. Verified and approved according to MID. IEC approval. Instrument values. larm function. - Communication - Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus. 2CMC485003F0001 B21 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty 1 pc Steel ctive energy 1 x 230 V C Class B (Cl. 1) Pulse output B CM100149R ,14 RS-485 B CM100150R ,15 M-Bus B CM100151R ,15 Bronze ctive and reactive energy, import/export. 1 x 230 V C Class B (Cl. 1) Reactive Cl. 2 Pulse output RS-485 B CM100152R ,15 Silver ctive and reactive energy, import/export, tariffs 1-4, tariff control via inputs and communication. 1 x 230 V C Class B (Cl. 1) Reactive Cl. 2 2 output, 2 input B CM100154R ,14 RS-485 B CM100155R ,15 M-Bus B CM100156R , CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

131 Electricity Meters B23 Three phase meter 65, 4 DIN with IR port 2CMC485001F0201 Description Direct connected electricity meter. Verified and approved according to MID. IEC approval. 2- and 3-element metering. Instrument values. larm function. Communication - Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus. 13 B23 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty 1 pc Steel ctive energy 3 x 230/400 V C Class B (Cl. 1) Pulse output B CM100163R Bronze ctive and reactive energy, import/export. 3 x 230/400 V C Class B (Cl. 1) Reactive Cl. 2 RS-485 B CM100164R M-Bus B CM100165R Pulse output RS-485 B CM100166R Silver ctive and reactive energy, import/export, tariffs 1-4, tariff control via inputs and communication. 3 x 230/400 V C Class B (Cl. 1) Reactive Cl. 2 2 output, 2 input B CM100168R RS-485 B CM100169R M-Bus B CM100170R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

132 Electricity Meters B24 Three phase meter 6, 4 DIN with IR port 13 Description Transformer CT connected electricity meter. Verified and approved according to MID. IEC approval. 2- and 3-element metering. Instrument values. larm function. Communication - Infrared (M-Bus). Optional - Communication with M-Bus, RS-485 Modbus, RS-485 EQ bus. B24 2CMC485002F0001 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty 1 pc Steel ctive energy 3 x 230/400 V C Class B (Cl. 1) Pulse output B CM100177R Bronze ctive and reactive energy, import/export. 3 x 230/400 V C Class B (Cl. 1) Reactive Cl. 2 RS-485 B CM100178R M-Bus B CM100179R Pulse output RS-485 B CM100180R Silver ctive and reactive energy, import/export, tariffs 1-4, tariff control via inputs and communication. 3 x 230/400 V C Class C (Cl. 0,5 S) Reactive Cl. 2 2 output, 2 input B CM100182R RS-485 B CM100183R M-Bus B CM100184R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

133 Electricity Meters B series Technical data B21 B23 B24 Voltage/current inputs Nominal voltage 230 V C 3x230/400 V C Voltage range VC (-20% - +15%) 3x VC (-20% - +15%) Power dissipation voltage circuits 0.9 V (0,4 W) total 1.6 V (0,7 W) total Power dissipation current circuits V (0.014 W) at 230 V C and I b V (0.007 W) per phase at 230 V C and I b Base current Ib 5 Rated current In 1 Reference current Iref 5 Transitional current Itr Maximum current Imax 65 6 Minimum current Imin Starting current Ist < 20 m < 1 m Terminal wire area 1-25 mm mm 2 Recommended tightening torque 3 Nm 1.5 Nm Communication Terminal wire area mm 2 Recommended tightening torque 0.25 Nm Transformer ratios Configurable current ratio (CT) 1/9-9999/1 Pulse indicator (LED) Pulse frequency 1000 imp/kwh 1000 imp/kwh 5000 imp/kwh Pulse length 40 ms 40 ms 40 ms General data Frequency 50 or 60 Hz ± 5% ccuracy Class B (Cl. 1) and Reactive Cl. 2 B (Cl. 1) and Reactive Cl. 2 B (Cl. 1) or C (Cl. 0,5 S) and Reactive Cl. 2 ctive energy 1% 1% 0.5%, 1% Display of energy 6 digit LCD 7 digit LCD Environmental Operating temperature 40 C C Storage temperature 40 C C Humidity 75% yearly average, 95% on 30 days/year Resistance to fire and heat Terminal 960 C, cover 650 C (IEC ) Resistance to water and dust IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC Mechanical environment Class M1 in accordance with the Measuring Instrument Directive (MID). (2004/22/EC). Electromagnetic environment Class E2 in accordance with the Measuring Instrument Directive (MID), (2004/22/EC). Outputs Current m Voltage V C/DC. For meters with only 1 output 5-40 VDC. Pulse output frequency Programmable: imp/kwh Pulse length Programmable: ms Terminal wire area mm 2 Recommended tightening torque 0.25 Nm Inputs Voltage V C/DC OFF 0-12 V C/DC ON V C/ V DC Min. pulse length 30 ms Terminal wire area mm 2 Recommended tightening torque 0.25 Nm EMC compatibility Impulse voltage test 6 kv 1.2/50μs (IEC ) Surge voltage test 4 kv 1.2/50μs (IEC ) Fast transient burst test 4kV (IEC ) Immunity to electromagnetic HF-fields 80 MHz - 2 GHz (IEC ) Immunity to conducted disturbance 150kHz - 80MHz (IEC ) Immunity to disturbance with harmonics 2kHz - 150kHz Radio frequency emission EN 55022, class B (CISPR22) Electrostatic discharge 15 kv (IEC ) Standards IEC , IEC class 1 & 2, IEC class 0,5 S, IEC class 2, IEC , GB/T , GB/T class 1 & 2, GB/T class 0,5 S, GB , EN , EN category, B & C Mechanical Material Polycarbonate in transparent front glass. Glass reinforced polycarbonate in bottom case and upper case. Polycarbonate in terminal cover. Dimensions Width 35 mm 70 mm Height 97 mm 97 mm Depth 65 mm 65 mm DIN modules BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

134 Electricity Meters C series Product brief 13 Key applications Landlord sub-metering Object metering Meter performance Direct connected up to 40 ctive energy Low power consumption larm function Communication Pulse output Installation Small size - 1 DIN (single phase) or 3 DIN (three phase) modules width Wide temperature range Easy configuration pprovals MID type approval annex B MID initial verification annex F IEC type approval 132 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

135 Electricity Meters C series Description 13 The EQ meters, C series are truly compact meters for single phase and three phase metering. The C series is mounted on a DIN rail and is suitable for installation in distribution boards and small consumer units. General features Only one module wide, the C series is a very compact meter for single phase and three phase applications. The meters have an LCD with large digits showing energy register and instrumentation values. The meters have a wide temperature range which makes it possible to install the meters in many locations. Navigating the meters are easily done via the pushbutton below the display. Instrumentation The C series meters support reading of instrument values. number of electrical properties can be read: Outputs The C series meters have an output that can be used as pulse output or alarm output. The alarm quantity and levels is easily configured on the meter with the push button. The output can be used for controlling external apparatus like a contactor or an alarm indicator (connected via an external relay). pprovals The C series meters are type approved according to IEC and MID. MID is the Measuring Instruments Directive 2004/22/EC from the European Commission. The type approval is according to standards that covers all relevant technical aspects of the meter. These include climate conditions, electromagnetic compatibility (EMC), electrical requirements, mechanical requirements and accuracy. MID versions have initial verification according to annex F of the Measuring Instruments Directive. Power factor ctive power Current Voltage BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

136 Electricity Meters C11 and C13 Single and three phase meter Description C11 Direct connected electricity meter. IEC approval. Instrument values. larm function. Optional - Verified and approved according to MID, 1 DIN. C11 2CMC486001F0001 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty 1 pc Steel ctive energy 1 x 230 V C Class B (Cl. 1) Pulse output C *) 2CM100014R Class 1 C CM170550R * ) MID approval Description C13 Direct connected electricity meter. IEC approval. 3 element metering. Instrument values. larm function. Optional - Verified and approved according to MID, 3DIN. C13 2CMC486004F0001 Ordering details Voltage V ccuracy Class I/O Communication Type Order Code P qty Steel ctive energy 3 x 230/400 Class B (Cl. 1) Pulse output C * ) 2CM100191R V C Class 1 C CM100192R * ) MID approval 1 pc 134 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

137 Electricity Meters C series Technical data C11 C13 Voltage/current inputs Nominal voltage 230 V C 3x230/400 Voltage range 230 V C (-20% - +15%) 3x V C (-20% - +15%) Power dissipation voltage circuits < 0.8 V (0.2 W) total 1.5 V (0.6 W) total Power dissipation current circuits 0.02 W at 230 V C and Ib 0.04 V (0.04 W) per phase at 230 V C and I b Base current Ib 5 Rated current In Reference current Iref 5 Transitional current Itr 0.5 Maximum current Imax 40 Minimum current Imin Starting current Ist < 20 m Terminal wire area 1-10 mm mm 2 Recommended tightening torque 0,8 Nm General data Frequency 50 or 60 Hz ± 5% ccuracy Class B (Cl.1) ctive energy 1% Display of energy 6 digits LCD Communication Terminal wire area Recommended tightening torque Pulse indicator (LED) Pulse frequency 1000 imp/kwh Pulse length 40 ms Environmental Operating temperature 25 C C Storage temperature 25 C C Humidity 75% yearly average, 95% on 30 days/year Resistance to fire and heat Terminal 960 C, cover 650 C (IEC ) Resistance to water and dust IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC Mechanical environment Class M1 in accordance with the Measuring Instrument Directive (MID). (2004/22/EC). Electromagnetic environment Class E2 in accordance with the Measuring Instrument Directive (MID), (2004/22/EC). Outputs Current m Voltage 5-40 V DC Pulse output frequency 100 (imp/kwh) Pulse length 200 ms Terminal wire area mm 2 Recommended tightening torque 0.8 Nm EMC compatibility Impulse voltage test 6 kv 1.2/50 µs (IEC ) Surge voltage test 4 kv 1.2/50 µs (IEC ) Fast transient burst test 4 kv (IEC ) Immunity to electromagneti HF-fields 80 MHz - 2 GHz at 10 V/m (IEC ) Immunity to conducted disturbance 150 khz - 80 MHz, (IEC ) Immunity to disturbance with harmonics 2kHz - 150kHz Radio frequency emission EN 55022, class B (CISPR22) Electrostatic discharge 15 kv (IEC ) Standards IEC , IEC class 1, GB/T , GBT class 1, GB , EN , EN category B Mechanical Material Glass reinforced polycarbonate Dimensions Width 17,5 mm 54 mm Height 111 mm 122 mm Depth 65 mm 65 mm DIN modules 1 3 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

138 CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

139 BB i-bus KNX Security and Surveillance Fault Monitoring and Data Logging SMB/S 1.1 Fault Monitoring Unit, MDRC It is used to detect and manage up to 100 fault messages which are processed within the unit and can be forwarded to a display unit. Furthermore, an optical and an acoustic collective status signal is provided. Messages can be acknowledged and data losses can be reported. The devices support message formats to DIN : messages with continuous lighting, new value messages with simple flashing light, initial value messages with simple acknowledge ment, motor messages. Current values can be centrally scanned. unit 2 SMB/S 1.1 GHQ R EUB/S 1.1 Monitoring Unit, MDRC Monitors up to 100 bus devices in KNX systems, which can be divided into 5 groups. The devices are monitored to ensure their presence and minimum functionality (send and receive). Monitoring can be undertaken based on the physical address or the group address. total of four different monitoring modes are available. unit 2 EUB/S 1.1 2CDG110066R BDB/S 1.1 Data Logging Unit, MDRC It detects local operation cycles and operating hours to plan the maintenance or durability evaluation of the devices. For each of the 35 channels to be monitored, limit values can be set and a message sent if this limit is exceeded. The logging of operating hours can be predetermined for the total or remaining time. These values can be modified via communication objects. unit 2 BDB/S 1.1 2CDG110067R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

140 BB i-bus KNX Security and Surveillance pproved Security with KNX 14 The compact solution for security applications the Security Terminals The Security Terminal provides a compact security solution for KNX applications for detection and signalling of intrusion, personal attack and technical hazards. They are used as the interface between the security technology sensors and KNX. Depending on the configuration, the devices feature 2, 4 or 8 inputs so-called detector circuits or zones. They are used for monitoring connected passive detectors (e.g. magnetic contacts, glass break sensors, etc.) to the BB i-bus KNX as well as for connection of floating contacts in applications with enhanced security requirements. Through the connection of security technology and KNX, the detectors employed can, in addition to the security functions, also be used for heating control (e.g. window contact signal for control of the heating valve) or lighting control (e.g. central switch off of the lighting when the alarm logic is set). The application program offers several functions for security applications, such as Direct and delayed setting Internal setting with occupancy and external setting when absent Setting of the connected detector types Reset input and setting input Detector monitoring Zones (detector circuits) can be switched off Different types of alarms Setting for freely programmable relay outputs, e.g. for direct control of signalling devices. The Security Terminals can be used as autonomous systems with the integrated alarm logic, in conjunction with the Security Module SCM/S or with an Intrusion larm Panel GM/ 8.1 or L CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

141 BB i-bus KNX Security and Surveillance pproved Security with KNX SCM/S 1.1 Security Module, MDRC The module provides the necessary logic functions to link the various KNX devices (e.g. zone terminals) to a security system. Up to 64 different zones can be evaluated via communication objects. rming, operation and display are also implemented using communication objects. The device has a freely programmable relay output for connection of a signal encoder. n uninterruptable KNX power supply with battery back-up is recommended for security function buffering on mains failure. unit 2 SCM/S 1.1 2CDG110024R MT/S M Security Terminal They are used as the interface between the security technology sensors and the KNX. The device features inputs, so-called zones. They are used for monitoring connected passive detectors, e.g. magnetic contacts and/or glass break sensors on the BB i-bus KNX and/or for connection of floating contacts in applications with enhanced security requirements. The device can be used as a system with autonomous alarm logic or in combination with the Security Module SCM/S or an Intrusion larm Panel. The device requires an external 12 V DC SELV auxiliary power supply, (e.g. NTU/S ). unit 8-fold, MDRC 4 MT/S M 2CDG110110R fold, MDRC 4 MT/S M 2CDG110109R fold, FM MT/U CDG110111R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

142 BB i-bus KNX Security and Surveillance The new KNX Security Panel 14 Professional alarm system for KNX experts With the new KNX Security Panel GM/ 8.1 BB presents the first security system that is compatible with both, the international KNX standard ( x ISO / IEC) and the international standard for alarm systems (ISO / IEC 62642). Therefore the KNX Security Panel GM/ 8.1 is ready for a worldwide usage and expands business opportunities of nearly 40,000 KNX partners in 124 countries. The new system is the perfect solution for projects ranging from simple to high security requirements. This innovation is the result of more than 30 years of system and application knowledge in alarm technology and building automation at BB CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

143 BB i-bus KNX Security and Surveillance The new KNX Security Panel Magnet reed contacts 14 Glass break sensors Water detector Gas detector Smoke detector Zone modules for security bus Motion detectors for security bus SafeKey setting device and SafeKey Evaluation Module larming Security bus KNX Bus for keypads Ethernet complete product product portfolio: One system all interfaces To fulfill the project requirements BB provides the user besides the new panel and keypad a complete product portfolio for professional alarm technology as well as known solutions for all trades of KNX building automation. The KNX Security Panel is for universal usage for all kinds of hazardous situations in buildings like intrusion, personal attack, smoke, gas- and water leakage. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

144 BB i-bus KNX Security and Surveillance The new KNX Security Panel 14 Ethernet connection for programming, diagnostics and operation via a standard webbrowser Direct inputs for security sensors Keypads Internal, external or remote alarming Security bus for security sensors, zone modules and setting devices KNX interface to display alarm states via displays of building automation and to control automatic building functions with support of security sensors. KNX Security Panel without cover, integrated zone modules and batteries The KNX Security Panel provides all needed system interfaces: n ethernet connection is used for programming, diagnostics and operation via a standard webbrowser as well as integration into the building network. The security sensors will be connected directly to the panel inputs or via the security bus, where the setting device for the system is also connected. Furthermore the panel provides interfaces for the also newly developed keypads and for internal, external or remote alarming. Finally the integrated KNX interface allows on the one hand to display alarm states via displays of building automation and on the other to control automatic building functions with support of security sensors CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

145 BB i-bus KNX Security and Surveillance The new KNX Security Panel GM/ 8.1 KNX Security Panel, SM NEW for the protection of small to medium residential or commercial properties against intrusion and technical faults. The Security Panel is suitable for up to five logical setting zones. It has 8 integrated zones for detectors, a Security Bus for Bus-detectors, Bus-Zone Modules or Setting devices, Ethernet connection (RJ45) for programming, operating and displaying system status via Web-Browser and an integrated KNX interface. The Security Panel GM/ 8.1 complies with the requirements to VdS classes, B and C, to the European Standard EN 50131, Grade 1 to 3 and to ISO/IEC Grade 1 to 3. unit GM/ 8.1 2CDG110150R Off the wall tamper contact for GM/ 8.1 W/Z 1.1 2CDG110174R BT/ 1.1 Keypad for GM/ 8.1 NEW to connect to Security Panel GM/ 8.1 via the Keypad-Bus. The Keypad allows easy operation of the Security Panel. System messages are displayed on a four-line LCD display. Fife Keypads can be connected to each Security Panel. There is no need for an external voltage supply, the keypads are supplied via the Keypad-Bus. unit BT/ 1.1 2CDG280001R MG/E Zone Module, 4fold NEW to connect to Security Panel GM/ 8.1 via the Security-Bus. For expansion of the Security-Panel by 4 detector zones. Used for connection to the exterior perimeter detectors such as magnetic reed contacts and passive glass break sensors. The module has 4 zones to which several detectors can be connected. The status of each zone is displayed with a status LED. The Zone Module delivers the control signals and the supply voltage for the external detectors. There is no need for an external voltage supply, the Zone Modules are supplied via the Security-Bus. unit to mount in the MG/E CDG110178R Security Panel housing in a surface mounting housing for installation in the building MG/ CDG110186R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

146 BB i-bus KNX Security and Surveillance Intrusion larm Panel L L240 Intrusion larm Panel L240 For the protection of small to medium residential and commercial properties against intrusion and technical faults. VdS approved as an Intrusion larm Panel for VdS classes, B, C. Corresponds to DIN VDE 0833 parts 1 & 3, Stage 3 according to European standard EN medium to high risk. unit L240/ENG 2CDG230017R L240/PT LCD Keypad for L240 For operation and programming of the panel. The messages are displayed on a two-line LCD display. Menu driven operation and programming of the panel. Internal and external setting on the keypad is possible. VdS class C. unit L240/PT 2CDG230014R XS/S 1.1 KNX-Interface for Intrusion larm Panel, MDRC The Intrusion larm Panel L240 with a comprehensive range of sensors for all surveillance tasks, and the comfortable arming mechanism SafeKey, provide a universal solution for professional applications. Integration into KNX systems is possible using the Interface XS/S1.1. ccordingly there are numerous benefits: For example, a door/window opening detector can be used to switch off the heating and save energy in the unset state. When an alarm is triggered, the KNX devices can carry out actions such as switching on the light or operating the blinds. The interaction offers further benefits in terms of system integration, which comply to the demands of the VdS up to Class C. unit 2 XS/S 1.1 2CDG110075R L208/V.24 Serial Interface Module for L240 For programming of the L240 via PC with serial interface V24, incl. Software WinPC. unit L208/V.24 GHQ R L240/IP IP Interface Module for L240 For programming of the L240 via PC with Ethernet interface, incl. Software WinPC. unit L240/IP 2CDG230013R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

147 BB i-bus KNX Security and Surveillance System Components SK7 Sealed Lead cid Battery, 12 V DC For Intrusion larm Panel emergency power. 2 units can be installed. VdS class C. unit SK7 GHV V SK17 GHV V IR/XB IR/XC Infra-Red Motion Detector for security-bus For direct connection to the security-bus of the Intrusion larm Panel GM/ 8.1 or L240. The motion detectors with passive infra-red technology are registered for VdS classes B and C (anti-masking monitored). They facilitate monitoring of an area with an IR range of up to 15 m. unit VdS-No. G IR/XB 2CDG230023R VdS-No. G IR/XC 2CDG230024R EIM/XB EIM/XC Dual Motion Detector for security-bus For direct connection to the security-bus of the Intrusion larm Panel GM/ 8.1 or L240. The Dual-Motion Detector combines proven passive infra-red technology with temperature-independent microwave technology. The combination of both functional principles results in a detector featuring high immunity to false alarms, even with unfavourable ambient conditions, and which still has high detection security. The detectors are registered for VdS classes B and C (anti-masking monitored). They facilitate monitoring of an area with an IR range of up to 15 m. unit VdS-No. G EIM/XB 2CDG230025R VdS-No. G EIM/XC 2CDG230026R MW Mounting Bracket For motion detectors. unit MW GHV V BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

148 BB i-bus KNX Security and Surveillance System Components 14 L240/MG2 Zone Bus-Module, 2-fold, FM For expansion of the panel by 2 detector circuits. Used for connection to the exterior perimeter detectors such as magnetic reed contacts and passive glass break sensors. The module has 2 zones to which 2 detectors can be connected via LS terminals. The module is an intelligent distributor by simple installation in a 60 mm installation box in the vicinity of the window. unit L240/MG2 2CDG220003R L840/MG4 Zone Bus-Module, 4-fold For expansion of the panel by 4 detector circuits. n SD enclosure is required for installation. unit L840/MG4 GHQ R WEL/, ES SafeKey Wall Reader, SM For setting/unsetting with the Evaluation Module L240/BS. The unit is actuated by inserting the electronic SafeKey chipkey. The SafeKey Wall Reader WEL is equipped with the key reader and an acknowledgement buzzer. VdS class C. unit WEL/, ES GHQ R WELT/, ES SCS SafeKey Wall Reader, SM For setting/unsetting with the Evaluation Module L240/BS. The unit is actuated by inserting the electronic SafeKey chipkey. The SafeKey Wall Reader WEL is equipped with the key reader and an acknowledgement buzzer. VdS class C. unit WELT/, ES GHQ R SafeKey Chipkey It is an electronic carrier medium for lock actuation and for setting/unsetting on a strike plate, door cylinder or wall reader. SafeKey Chipkey can be authorized for any number of different SafeKey systems with different levels of authorization. unit SCS GHQ R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

149 BB i-bus KNX Security and Surveillance System Components SafeKey Evaluation Module For connection of the SafeKey components as well as all components required for a setting door (magnetic contacts, lock bolt switching contact, bolt lock, internal siren). For direct connection to the security-bus of the Intrusion larm Panel GM/ 8.1 or L240. The management of the electronic keys from the SafeKey range is undertaken completely on the LCD keypad of the panel. 14 L240/BS unit L240/BS GHQ R SSM/ SafeKey Switching Module is used for an easy connection and evaluation of the SafeKey Wall Reader with or without keypad (WEL or WELT). pplicable for potential-free switching of electrical components up to 5 at a max. voltage of V DC/C, i.e. electrical door opener or garage doors, or to set/ unset a KNX security system via the connection to a Security Terminal MT/x. In subject to the housing type the module can be used for surface or flush mount. 12 V power supply is required. unit Surface mounting SSM/ 2CDG240019R Flush mounting SSM/U 2CDG240020R Electromechanical Bolt Lock Prevents access to the set zone of an Intrusion larm Panel. The unit is mounted in the door frame. Only a single bore or the counterpart for the locking bolt in the door panel is required. Suitable for use with WEL and WELT. VdS class C. ESPE unit ESPE GHV V Replacement Locking Bolt EVSB GHV V Mounting kit, flat door panel MSP GHV V and frame Mounting kit, raised door MSE GHV V panel SD/GP Distribution Enclosures For installation of the Bus Modules L840/MG4 and L240/BS. unit Surface mounting SD/GP GHQ R Flush mounting SD/GUP GHQ R Wall box for SD/GUP SD/ED GHQ R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

150 BB i-bus KNX Security and Surveillance System Components 14 MRS/W Magnet Reed Contact Set For opening surveillance of windows and doors, complete for bolting or drilling Contents: 1 magnet, 1 reed contact with 4.0 m connection cable LIYY 4 x 0.14 mm 2, 2 housings, 2 spacer plates, 2 flanges and 4 anti-magnetic fixing screws. VdS No. G VdS class B. unit white MRS/W GHQ R brown MRS/B GHQ R Saver Set (20 pcs.), white VMRS/W GHQ R Saver Set (20 pcs.), brown VMRS/B GHQ R RTK Rolling Door Magnet Reed Contact Set For monitoring opening or rolling doors or other large doors in the industrial field. Contents: 1 magnet, 1 reed contact with 2 m connection cable 4 x 0.14 mm 2, 1 m protective tubing and 1 set of mounting accessories. Degree of protection: IP 68; Environmental class to VdS 4; VdS class B. unit RTK GHQ R SPGS/W Glass Break Sensor For surveillance of glass surfaces of windows, display windows and doors with high interference immunity and integrated memory display. For operation directly on detector circuits of intrusion alarm panels or security terminals. Extremely compact dimensions. Dimensions: H x W x D = 18 x 18 x 9 mm. Mounted onto glass using Loctite adhesive (LKS). With 5 m connection cable. VdS No. G VdS class B. unit white SPGS/W GHV V brown SPGS/B GHV V Mechanical Glass GP2 GHV V Break Test Device Loctite adhesive LKS GHQ R Lock Bolt Switching Contact For installation in the strike plate, for lock monitoring on doors. Water-tight IP 67, with 2.5 m connection cable LIYY 3 x 0.14 mm 2. VdS No. G VdS class C. WRK/W unit WRK/W 2CDG250003R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

151 BB i-bus KNX Security and Surveillance System Components VSUE Window Lock Monitoring Contact Lock monitoring is carried out with a special magnet and a reed contact. The magnet is mounted on the push rod of the window sash while the reed contact is mounted on the frame. The connection cable LIYY 4 x 0.14 mm 2 is 4 m in length. VdS No. G VdS class C. unit VSUE GHV V DB Window opening Plungers Indirect lock monitoring by mechanical push opening of the window in conjunction with magnetic contacts that monitor opening. vailable in 2 spring strengths. unit 150 N DB GHV V N DB1 GHV V ND/W Emergency Call Button For manual alarm tripping. Complies with the police regulations since it features permanent trip recognition, momentary-contact function, with cover contact. Surface mount version. Colour: white. VdS class C. unit Surface mounting ND/W GHQ R Flush mounting NDU/W GHQ R Spare Papers (10 pcs.) EP GHQ R ND/W Cover plate Used primarily in the banking sector or other institutions, where unintentional alarm triggering is possible due to public access. unit ND/W GHQ R IR/KB Passive Infra-Red Detector For conventional wiring to zone inputs of an Intrusion larm Panel or a KNX Sercurity Terminal. With a volumetric lens for interior monitoring. Can be optionally set for hall monitoring function up to 15 m. Color: RL 9010 pure white; for use up to VdS class B. unit VdS-No. G IR/KB 2CDG230027R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

152 BB i-bus KNX Security and Surveillance System Components 14 EIM/KB Dual Motion Detector This new dual detector is based on proven detection principles of the EIM detector ND incorporation of infrared technology and electromagnetic field detection. The detector enables a detection range of 15 m with 17 zones on 6 levels. The range of the infra-red component the electromagnetic field can be adjusted separately using a jumper. Up to VdS class C; Color RL 9010 pure white. unit VdS-No. G EIM/KB 2CDG230028R VdS-No. G EIM/KC 2CDG230029R MW Mounting Bracket For motion detectors. unit MW GHV V EIM/D Dual Ceiling Detector Operates according to the proven detection principle of the EIM detector (infra-red technology and electromagnetic field) over 360. The range of the infrared component can be adapted via the mounting height while the range of the electromagnetic field can be adjusted separately using a jumper. The detector is fitted with a walk test LED. Colour: RL 9010 pure white. unit EIM/D 2CDG230039R SGL Gas Detector For measurement and evaluation of the concentration of natural gas or liquefied gas in the air. The detector requires a V DC voltage supply and has a normally open relay output contact for connection to the intrusion alarm panels and fire alarm panels, features an LED display and a Piezo buzzer. For ceiling and wall mounting. unit SGL GHQ R SWM 4 Water Detector resin-encapsulated water detector with gold-plated Termipoint pins, detects water ingress, e.g., pipe fractures, ingress of groundwater and sewage, water damage caused by washing machines and dishwashers etc. before the damage becomes too expensive. For operation directly on detector circuits of intrusion alarm panels or security terminals. unit SWM 4 GHQ R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

153 BB i-bus KNX Security and Surveillance System Components SWM 4/RN Water Detector with Relay Output Features a potential free changeover contact output, an LED parallel output and a LED display. The detector resets itself automatically when the affected area dries out. The device draws its power from an external V DC voltage source. unit SWM4/RN GHQ R FC650/O Optical Smoke Detector Optical smoke detector in threshold alarm technology that detects smoke according to the scattered-light principle The detectors feature an alarm indicator on the detector head that is visible from all angles, and which can be be triggered with a permanent magnet for test purposes. detector base is provided for mounting and cable connection purposes into which the detector is simply screwed in via the bayonet connection. Each detector is equipped with an alarm LED, which displays the stored alarm in the event of an a alarm Detector/base diameter: 110 mm. VdS approved. unit FC650/O 2CDG430073R FC650/TMX Heat Detector Static Heat Detector in threshold alarm technology, trigger temperature 78 C. The detectors feature an alarm indicator on the detector head that is visible from all angles, and which can be be triggered with a permanent magnet for test purposes. detector base is provided for mounting and cable connection purposes into which the detector is simply screwed-in via the bayonet connection. Each detector is equipped with an alarm LED, which displays the stored alarm in the event of an a alarm. Detector/base diameter: 110 mm. VdS approved. unit FC650/TMX 2CDG430081R FC600/BREL Detector Base, 12 V Enables system-independent connection of the FC650 series fire detector to systems or devices that are not specifically designed for this detector technology. Examples include Intrusion larm Panels, KNX Security Terminals, elevator controls or other signal processing equipment. The detector base must be supplied by either a 12 V or a 24 V DV voltage supply. floating 30 V DC/1 changeover contacting is provided for transferring an alarm. unit FC600/BREL 2CDG430051R BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

154 BB i-bus KNX Security and Surveillance System Components 14 FP03 Testing erosol For optical smoke detector testing, 250 ml. unit FP03 GHV V Reed Relay, 12 V For connection, e.g. to transistor outputs of Intrusion larm Panels. Coil voltage V DC. Current consumption 5 m at 12 V DC. Contact loading 24 V/100 m. unit RL GHV V Electronic Solid-State Siren Electronic solid-state siren with intermittent tone for alarm purposes in indoor installations. External dimensions: ø x H = 90 x 37 mm. SSS unit SSS GHV V Siren in Enclosure n aluminium protective housing with additional protective enamel coating. Protected against sabotage by a case tamper contact. The alarm inputs are wired onto a terminal strip. With fixing screw (M4) for potential equalization on the base. Dimensions: H x W x D = 200 x 205 x 88 mm; Color: RL 9002 Environmental class III to VdS. SSF/G unit SSF/G GHQ R SSF/GB Combination Signalling Device Siren in an aluminium protective housing with additional protective enamel coating and strobe light mounted on top. Protected against sabotage by a case tamper contact. The alarm inputs are wired onto a terminal strip. Dimensions: H x W x D = 258 x 205 x 88 mm; Color RL VdS No. G VdS class C. unit SSF/GB GHQ R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

155 BB i-bus KNX Security and Surveillance Busch Smoke and Heat larm 6833/ Busch Smoke larm ProfessionalLine NEW For early detection of smouldering fires and open fires with smoke development indoors according to the photooptical measurement principle (Tyndall). With installed Lithium battery. Battery life min. 10 years. With test button and muting. Can be networked with up to 12 detectors using the radio module. Can be networked via 2-wire twisted pair cable with up to 12 detectors. coustic alarm: installed horn (85 db). Cyclic functional test. Including attachment material VdS certified. Conform to EN studio white. 14 unit not networkable networkable 6833/ / Busch Heat larm ProfessionalLine NEW Signal triggered at over 57 C. With installed Lithium battery. Battery life min. 10 years. With test button and muting. Can be networked via 2-wire twisted pair cable with up to 12 detectors. Can be networked with up to 12 detectors using the radio module. coustic alarm: installed horn (85 db). Cyclic functional test. Including attachment material VdS certified. Conform to EN unit studio white 6835/ Busch Smoke larm Radio Module For wireless networking of multiple Busch smoke alarms / heat alarms. With installed Lithium battery. Battery life min. 10 years. Radio frequency: 868 MHz. Range: max. 100 m outdoors, max. 30 m indoors. unit Busch Smoke larm Relay For connecting external systems, e.g. KNX. Relay contact, floating changeover contact 230 V~ max. 5. Cable connection: up to 2 x 2 x 1.5 mm². With installed radio module. Rated voltage: 230 V~ unit studio white Busch Smoke larm Remote Control For service purposes. With muting, test and search function. unit studio white BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

156 WaveLINE Wireless Control RF Sensors SM WaveLINE movement detector, rticle-no GM The WaveLINE Busch-Watchdog 220 is a batteryoperated movement detector. Since it is installed without cables it can be mounted in the most ideal position. The battery has a service life of 5 years. 02 WaveLINE media converter TP-RF, rticle-no The KNX and Busch radio control are coupled via the WaveLINE media converter TP-RF. Telegrams can be exchanged in both directions. One application serves to transmit the window sensor to the KNX system. 03 Window sensor, rticle-no The WaveLINE window sensor is retrofitted between the window and window handle, which means the original window handle is retained. The window handle is used for the following window positions: opened, tilted and closed. 04 Universal detector, rticle-no The WaveLINE universal detector is suited for skylights or sliding doors and is activated via a reed contact. The universal detector has a second channel which can be permanently wired to a floating contact (NO or NC contacts). 05 Remote control RF, rticle-no The remote control is used as mobile control for the WaveLINE. Loads can be controlled individually and scenes can be started. Control elements Switch ranges 1gang 2gang 4gang 1gang 2gang pure stainless steel solo 6731-xx xx xx-500 Busch-axcent 6731-xx xx xx-500 future linear 6731-xx xx xx-500 Reflex SI Busch-Duro 2000 SI CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

157 WaveLINE Wireless Control RF ctuators / Displays NEW NEW 06 NEW gang WaveLINE actuator, rticle-no gang WaveLINE actuator, rticle-no WaveLINE dimming actuator, rticle-no WaveLINE blind actuator, rticle-no gang WaveLINE actuator, rticle-no WaveLINE binary input, 2gang rticle-no WaveLINE LED display, 4gang with switching function, rticle-no Before fter Usage of frequency might be restricted in certain countries. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

158 WaveLINE Wireless Control Transmitter Wall-mounted transmitter WaveLINE 1-channel 1gang wall-mounted transmitter independent of mains power supply. For switching and dimming. For controlling blinds and light scenes. 1 radio channel can be operated or up to 2 light scenes can be called up. For flush-mounted WaveLINE actuators , 6702, 6703, 6704 and For LED display WaveLINE 6730-xxx. Compatible with WaveLINE KNX gateway TP-RF Send frequency: 868 MHz. Free-field range: approx. 100 m. Power supply: lithium button cell battery Type CR2032. Battery included in delivery; service life: typically 5 years. unit Busch-Duro 2000 SI white /10 Reflex SI alpine white / Wall-mounted transmitter WaveLINE 2-channel 2gang wall-mounted transmitter independent of mains power supply. For switching and dimming. For controlling blinds and light scenes. 2 radio channels can be operated or up to 4 light scenes can be called up. For flush-mounted WaveLINE actuators , 6702, 6703, 6704 and For LED display WaveLINE 6730-xxx. Compatible with WaveLINE KNX gateway TP-RF Send frequency: 868 MHz. Free-field range: approx. 100 m. Power supply: lithium button cell battery Type CR2032. Battery included in delivery; service life: typically 5 years unit Busch-Duro 2000 SI white /10 Reflex SI alpine white /10 future linear ivory white /10 aluminium silver 2) /10 studio white /10 pure stainless steel 2) stainless steel / CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

159 WaveLINE Wireless Control Transmitter Wall-mounted transmitter WaveLINE 2-channel 2gang wall-mounted transmitter independent of mains power supply. With labelling field and labelling strip. For switching and dimming. For controlling blinds and light scenes. 2 radio channels can be operated or up to 4 light scenes can be called up. For flush-mounted Wave- LINE actuators , 6702, 6703, 6704 and For LED display WaveLINE 6730-xxx. Compatible with WaveLINE KNX gateway TP-RF Send frequency: 868 MHz. Free-field range: approx. 100 m. Power supply: lithium button cell battery Type CR2032. Battery included in delivery; service life: typically 5 years. 15 unit future linear ivory white /10 aluminium silver 2) /10 studio white /10 pure stainless steel 2) stainless steel / Wall-mounted transmitter WaveLINE 4-channel 4gang wall-mounted transmitter independent of mains power supply. With labelling field and labelling strip. For switching and dimming. For controlling blinds and light scenes. 4 radio channels can be operated or up to 8 light scenes can be called up. For flush-mounted Wave- LINE actuators , 6702, 6703, 6704 and For LED display WaveLINE 6730-xxx. Compatible with WaveLINE KNX gateway TP-RF Send frequency: 868 MHz. Free-field range: approx. 100 m. Power supply: lithium button cell battery Type CR2032. Battery included in delivery; service life: typically 5 years. unit future linear ivory white /10 aluminium silver 2) /10 studio white /10 pure stainless steel 2) stainless steel /10 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

160 WaveLINE Wireless Control Transmitter Remote control WaveLINE 1) Network-independent radio control. For switching and dimming. For controlling blinds and light scenes. With 3 groups (, B or C) with 5 pairs of channels. There are 15 radio channels operated singly or up to 30 light scenes can be called. With LL OFF function for associated actuators. For flush-mounted WaveLINE actuators , 6702, 6703, 6704 and For LED display WaveLINE 6730-xxx. Compatible with WaveLINE KNX gateway TP-RF Send frequency: 868 MHz. Free-field range: approx. 100 m. Power supply: lithium button cell battery Type CR2032. Battery included in delivery; service life: typically 5 years. unit black / WaveLINE binary input, 2gang, 230 V~ NEW Radio control telegrams are sent when the two extension units are activated with mains voltage (C 230 V~). Operation also possible via conventional push-buttons (2020 US, 2012/6 UK). The 2gang binary input has 5 function modes 2-channel switching; 2-channel dimming; 1-channel blind; Two-channel light scene control; Channel 1: Switching ON. Channel 2: Continuous switching ON/OFF. In dependence of the selected function, it can be combined with WaveLINE actuators , 6702, 6703, 6704, Compatible with WaveLINE KNX gateway TP-RF Repeater function can be activated for extended range. For universal attachment or installation. Phase and neutral conductor required. For installation in (deep) flush-mounted boxes to German Standard DIN 49073, Part 1. Send/receive frequency: 868 MHz. Free-field range: approx. 100 m. Control element: djustable potentiometer. Display elements: LED for status display. Rated voltage: 230 V~, +10 % / 10 %. Rated frequency: 50 Hz. Inputs: 2. Polling voltage: 230 V~, potential-connected. unit white / CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

161 WaveLINE Wireless Control Transmitter 6747 GM Busch-Watchdog 220 WaveLINE Wireless movement detector for detecting thermal motion. With display for detection and status indication. With ground and rear-field detection. With high-quality lens for optimum detection. Surveillance density: 84 sectors with 336 switching segments. With integrated dismantling protection. ll functions controlled by microprocessor. With automatic range stabilization. With automatic interference suppression. With automatic dazzle-proofing. With automatic battery monitoring. Battery type: Lithium batteries 1250 mh (L V). Battery included in delivery. Battery service life: typically 5 years, therefore practically maintenance-free. With brightness-independent test mode for evaluating the detection zone. Individual adjustment of detection range via enclosed protective foil which can be cut to size. Combinable with switch actuator WaveLINE, 1gang, with extension unit Compatible with WaveLINE KNX gateway TP-RF For standalone and group operation. Switch-off delay: 3 min. (single mode), individually adjustable at actuator (group mode). Send frequency: 868 MHz. Free-field range: approx. 100 m. Rated voltage: 4.5 V. Detection range: frontal: 16 m, lateral: 16 m. Detection angle: 220. Brightness limit value: 0.5 Lux 300 Lux, Daytime operation. Mounting height: 2.5 m. unit brown 6747 GM alpine white 6747 GM silver metallic 6747 GM anthracite 6747 GM BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

162 WaveLINE Wireless Control ctuators, RF/ KNX Media Converters WaveLINE switch actuator, 1gang, with extension unit NEW For wireless switching of electrical loads. Functions via radio control: ON/OFF, timer and light scene control. Functions via the extension unit: ON/OFF, timer and sending a radio control telegram. Operation also possible via conventional push-buttons (2020 US, 2012/6 UK). For Busch-Watchdog WaveLINE. For wall mounted transmitter Waveline 6731-xxx, 6732-xxx und 6733-xxx. For remote control WaveLINE For WaveLINE window position sensor x. For WaveLINE 6721-xx universal signalling unit. For Busch-EnergyControl 6762-xx. Compatible with WaveLINE KNX gateway TP-RF Controllable up to 32 transmission addresses. Send/receive frequency: 868 MHz. Free-field range: approx. 100 m. Control element: djustable potentiometer. Display elements: Status indication of output via LED. Rated voltage: 230 V~, +10 % / -10 %. Rated frequency: 50 Hz. Inputs: 1. Polling voltage: 230 V~, Sensing pulse, L-wire. Outputs: 1x Normally open contact, potential-bound. unit / Switch actuator WaveLINE For wireless switching of electrical loads. For functions ON/OFF, timer and lightscene control. For wall mounted transmitter Waveline 6731-xxx, 6732-xxx und 6733-xxx. For remote control WaveLINE For WaveLINE window position sensor x. For WaveLINE 6721-xx universal signalling unit. For Busch-EnergyControl 6762-xx. Compatible with WaveLINE KNX gateway TP-RF Controllable up to 32 transmission addresses. Send/receive frequency: 868 MHz. Free-field range: approx. 100 m. Control element: djustable potentiometer. Display elements: Status indication of output via LED. Rated voltage: 230 V~, +10 % / 10 %. Rated frequency: 50 Hz. Outputs: 1x Normally open contact, potential free. unit / gang switch actuator WaveLINE For wireless switching of electrical loads. For operation mode 2gang switch, 2 separate outputs. For operation mode timer: output 1 (eg lighting), output 2: ON/Off delay in dependence of output 1 (eg fan control). For functions: ON/OFF and light scene control. For wall mounted transmitter Waveline 6731-xxx, 6732-xxx und 6733-xxx. For remote control WaveLINE For WaveLINE window position sensor x. For WaveLINE 6721-xx universal signalling unit. For Busch-EnergyControl 6762-xx. Compatible with WaveLINE KNX gateway TP- RF Controllable up to 32 transmission addresses. Send/receive frequency: 868 MHz. Free-field range: approx. 100 m. Control element: djustable potentiometer. Display elements: Status indication of output via LED. Rated voltage: 230 V~, +10 % / 10 %. Rated frequency: 50 Hz. Outputs: 2x Normally open contact, potential-bound. unit / CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

163 WaveLINE Wireless Control ctuators, RF/ KNX Media Converters Universal dimming actuator WaveLINE For wireless switching and dimming of electrical loads. For functions ON/OFF, dimming and lightscene control. With soft ON/OFF function. With selectable light value storage. For wall mounted transmitter Waveline 6731-xxx, 6732-xxx und 6733-xxx. For remote control Wave- LINE Compatible with WaveLINE KNX gateway TP-RF Repeater function can be activated for extended range. Controllable up to 32 transmission addresses. Send/receive frequency: 868 MHz. Free-field range: approx. 100 m. Control element: djustable potentiometer. Display elements: Status indication of output via LED. Rated voltage: 230 V~, +10 % / 10 %. Rated frequency: 50 Hz. Outputs: 1x dimming channel. Suitable for: 230 V incandescent lamps. Output voltage: 230 V~. Rated power: W. 15 unit / WaveLINE series/blind actuator with extension unit NEW For wireless switching of electrical loads. For driving and adjusting blinds/shutters and awnings over radio. Functions via radio control: 2gang switch, blind switch and light scene control. Functions via extension unit: 2gang switch, blind switch and send radio control telegram. Operation also possible via conventional push-buttons (2020 US, 2012/6 UK). For wall mounted transmitter Waveline 6731-xxx, 6732-xxx und 6733-xxx. For remote control Wave- LINE For WaveLINE window position sensor x. For WaveLINE 6721-xx universal signalling unit. For Busch-EnergyControl 6762-xx. Compatible with WaveLINE KNX gateway TP-RF Controllable up to 32 transmission addresses. Send/receive frequency: 868 MHz. Free-field range: approx. 100 m. Control element: djustable potentiometer. Display elements: Status indication of output via LED. Rated voltage: 230 V~, +10 % / 10 %. Rated frequency: 50 Hz. Inputs: 2. Polling voltage: 230 V~, Sensing pulse, L-wire. Outputs: 2x Normally open contact, potential-bound. unit / KNX TP/RF WaveLine Gateway, SM Media converter with internal antenna for conversion of KNX RF WaveLine radio signals to KNX twisted pair networks with 24 channels. For the evaluation and transfer of up to 24 channels each with 4 sub-channels as transmitter or receiver. Simple operation due to programming button and display on the device. Is surface-mounted. The KNX/WaveLine Gateway is powered via KNX and does not require an additional power supply. unit BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

164 WaveLINE Wireless Control Window Sensor, Universal Detector WaveLINE LED display For status display of window handle positions: open = red, closed = green, tilted = yellow. Direct onsite operation possible for switching / dimming an electrical device depending on the flush-mounted insert. 4 individual LED display channels. Up to 8 WaveLine transmitters can be taught-in on each LED display channel. Up to 8 WaveLine transmitters can be taught-in on onsite operation. User-friendly start-up without PC / software. Printed labelling sheet with 8 different inlay sheets (see labelling sheet 1799 xx). For WaveLINE window position sensor x. For WaveLINE 6721-xx universal signalling unit. For Busch-Watchdog 220 WaveLINE 6747 GM. For Busch-Universal relay switch insert 6404 U. For universal dimmer switch insert 6595 U. Free-field range: approx. 100 m. Send/receive frequency: 868 MHz. unit Busch-Duro 2000 SI white Reflex SI alpine white G WaveLINE LED display For status display of window handle positions: open = red, closed = green, tilted = yellow. Direct onsite operation possible for switching / dimming an electrical device depending on the flush-mounted insert. 4 individual LED display channels. Up to 8 WaveLine transmitters can be taught-in on each LED display channel. Up to 8 WaveLine transmitters can be taught-in on onsite operation. User-friendly start-up without PC / software. Printed labelling sheet with 8 different inlay sheets (see labelling sheet 1799 xx). For WaveLINE window position sensor x. For WaveLINE 6721-xx universal signalling unit. For Busch-Watchdog 220 WaveLINE 6747 GM. For Busch-Universal relay switch insert 6404 U. For universal dimmer switch insert 6595 U. For BB i-bus KNX devices 6110 U, 6114 U, 6120 U-102. Free-field range: approx. 100 m. Send/receive frequency: 868 MHz. unit alpha platinum 3) bronze 3) ivory G studio white matt studio white G palladium 3) titanium 3) CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

165 WaveLINE Wireless Control Window Sensor, Universal Detector WaveLINE LED display For status display of window handle positions: open = red, closed = green, tilted = yellow. Direct onsite operation possible for switching / dimming an electrical device depending on the flush-mounted insert. 4 individual LED display channels. Up to 8 WaveLine transmitters can be taught-in on each LED display channel. Up to 8 WaveLine transmitters can be taught-in on onsite operation. User-friendly start-up without PC / software. Printed labelling sheet with 8 different inlay sheets (see labelling sheet 1799 xx). For WaveLINE window position sensor x. For WaveLINE 6721-xx universal signalling unit. For Busch-Watchdog 220 WaveLINE 6747 GM. For Busch-Universal relay switch insert 6404 U. For universal dimmer switch insert 6595 U. Free-field range: approx. 100 m. Send/receive frequency: 868 MHz. 15 unit future linear anthracite ivory white aluminium silver 1) studio white studio white, matt 1) black matt 1) solo ivory white studio white grey metallic 1) yellow Busch-axcent studio white chalet-white carat 2) anthracite ivory white studio white pure stainless steel 1) stainless steel BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

166 WaveLINE Wireless Control Window Sensor, Universal Detector U Busch-Universal relay switch insert For switching incandescent lamps, 230 V tungsten halogen lamps, fluorescent lamps and lowvoltage halogen lamps, that are actuated via transformers. 3 wire connection (neutral conductor required). With operating mode switch for operating mode: switch, time switch. Operation also possible via conventional push buttons (2020 US, 2021/6 UK). For LED display WaveLINE 6730-xxx. Rated voltage: 230 V~, +10 % / 10 %. Rated frequency: 50 Hz. Inputs: 1. Polling voltage: 230 V~, Sensing pulse, L-wire. Outputs: 1x Normally open contact, potential-bound. Suitable for: ohmic, capacitive and inductive loads. Rated current: 10 X. Rated power: 2300 W/V. unit 6404 U U Universal Dimmer Switch Insert For dimming and switching of incadescent lamps, 230 V halogen lamps and low-voltage halogen lamps with conventional or electronic transformers. 2-wire connection (neutral conductor not required). With soft ON/OFF function. Operation also possible via conventional push buttons (2020 US, 2021/6 UK). Do not operate conventional transformers and electronic transformers together on the universal dimmer switch insert. For LED display WaveLINE 6730-xxx. Rated voltage: 230 V~, +10 % / 10 %. Rated frequency: 50 Hz. Inputs: 1. Polling voltage: 230 V~, Sensing pulse, L-wire. Outputs: 1x electronic output, potential-bound. Suitable for: ohmic, capacitive and inductive loads. Rated power: W/V. unit 6595 U CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

167 WaveLINE Wireless Control Window Sensor, Universal Detector WaveLINE window sensor For monitoring and transmission of the current window handle position (window open, closed, tilted). The WaveLINE window sensor transmits the current window handle position immediately upon operation. Existing window handle is used. The WaveLINE window sensor is installed between the existing window handle and window frame. Suitable for window handle: 7 mm square fastener, 43 mm attachment screw separation, lifter dia. 10 and 12 mm, max. mounting plate size 34 x 77 mm (WxH). No wire laying required. ccessories for assembly (square fastener extension, screws, adapter for lifter) of the WaveLINE window position sensor included in delivery. Battery included in delivery. Battery service life: typically 5 years, therefore practically maintenance-free. Monitoring of battery life and transmission of battery condition. For LED display WaveLINE 6730-xxx. For flush-mounted WaveLINE actuators , 6702, 6703, 6704 and Compatible with WaveLINE KNX gateway TP-RF Free-field range: approx. 100 m. Send frequency: 868 MHz. unit studio white matt basalt black stainless steel 1) WaveLINE universal sensor For monitoring and transmission of the state (open, closed) of dormer windows, skylights, doors and gates. For window surveillance with open fireplace and extractor hood pursuant to rticle 4 of the German Fire Prevention Regulations. dditional connection option for an external, potential-free sensor (choice of normally closed or normally open contact). Isolated evaluation and monitoring of channels. The WaveLINE universal sensor immediately transmits the current information when there is a change in state. ddition cyclic transmission for monitoring of the transmission link and the fault-free state of equipment. ttachment of WaveLINE universal sensor and magnets by using adhesive foil or screws. ccessories (adhesive foil, screws, magnet) included in delivery. Battery included in delivery. Battery service life: typically 5 years, therefore practically maintenance-free. Monitoring of battery life and transmission of battery condition. For LED display WaveLINE 6730-xxx. For flush-mounted WaveLINE actuators , 6702, 6703, 6704 and Compatible with WaveLINE KNX gateway TP-RF External sensor max. wire length: 5 m. External sensor terminal connection diameter : mm² (single wire). Free-field range: approx. 100 m. Send frequency: 868 MHz. unit studio white matt basalt black ) Surface painted. BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

168 Newron Integration in Building Management Systems 15 Modern buildings today are more than merely the expression of future-oriented architecture. Integral systems must do justice to the increasing demands for energy efficiency, comfort, safety and profitable operation. For this, real estate needs intelligence in the form of well-designed technology. It is used to integrate information of the entire building auto-mation and to control heating and cooling systems, ventilation and air conditioning systems, lighting, sun-shading systems, as well as fire protection and safety systems. Depen ding on the type of its use, a building presents special challenges to everyone concerned. That is why Busch-Jaeger, as subsidiary of the expert global brand BB, now offers an integral solution Building Space. Under this umbrella all available expert know-how of building automation as well as the electrical and building systems technology sectors is merged as solution for buildings of the future. This portfolio of products and services is unique. With this growing power of expertise, efficient buildings can be made a reality safely and reliably from functional buildings up to exclusive luxury hotels. nd that on an international level. This how impressive solutions with the greatest possible freedom for design and implementation are created. Because Building Space solutions adapt themselves precisely to the respective object and its use. Even later modifications and extensions are possible at any time. When the building is to be used later for a different purpose, for example. Newron solutions guarantee an assured future and efficient opera tion. Thanks to openness and flexibility they are suitable for a complete IT and architectural building management solution for intelligent functional buildings. Effiiciency Building automation Profiitability Energy efficiency Comfort Safety Building Space Light switch & System technology Design Simplicity 166 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

169 Newron Total Networking System integrators can now work even more efficiently. Because with the innovative Newron solutions BB and Busch-Jaeger offer simple and efficient possibilities for intelligent building management. More possibilities in less time. Newron solutions allow a simple and flexible data exchange to take place between the different levels of a building management system and the most commonly used protocols used in functional buildings. nd here the solutions support all open standards such as BCnet, LON, KNX, Modbus, OPC, M-Bus and obix. This kind of flexi bility allows devices of different manufacturers and different protocol families to be combined in a building in a very simple way. The performance of the system is designed for processing large amounts of data and the efficient integration of numerous data points. Newron solutions support distributed IT architecture as well as IP convergence. The term convergence in general means the integration of forms of communication based on different technologies into a single network. IP convergence in the context of building management refers to the integration of different bus systems into one IP network. IP convergence offers a number of advantages with regard to expandability, performance, a uniform infrastructure as well as the possibility of joint management. This creates the prerequisites for the integral, service-oriented consideration of information processing. The outstanding features of Newron solutions are the intuitively operable user interface and the easy-to-understand internal architecture. They are ideally suited for medium to large projects in functional buildings. Newron solutions offer the system inte grator the working environment for processing major projects more efficiently and to simultaneously reduce integration time. Newron solutions follow an integrating approach and are therefore the direct interface to all central levels of intelligent building management. They form the bridge between technical system components and management level. Newron in a practical way supplements the numerous innovative KNX solutions for building automation in the existing program and rounds off the portfolio. For planners and system integrators Newron opens new possibilities and a highly attractive field of business for example, the integration of KNX into the different trades of a building management system. 16 Tel viv Museum of rt, Herta & Paul mir Building BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

170 Newron ll the advantages at a glance 16 domoov domoov is a building management software for building automation and makes possible the exchange of data between different protocols. The user-friendly interface and the simple internal structure ensure short programming times and facilitate modification and adaptation. Software solution» Fast to configure» User-friendly HMI (Human Machine Interface)» Supports decentralized IT structure» Multi-protocol gateway supports the protocols: KNX, LonWorks, BCnet, Modbus, M-bus» Universal SCD server OPC, BCnet, obix» Integrated services: schedule/calendar, trends, alarms 168 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

171 Newron 16 dogte dogte is an automation server optimized to domoov that is equipped with all necessary physical interfaces, which can also take over backup and remote control functions related to rooms. MOOVnGROUP MOOVnGROUP is an engineering tool, which as application for the KNX commissioning software ETS4 with a graphic user interface, facilitates the setup and editing of KNX projects. Here for example group addresses are automatically generated. utomation-server» utomation server that works functionally stable» ttuned to the requirements of functional buildings and the building management software domoov» Makes available all necessary interfaces» Redundancy: can be defined as backup device» dditional functions: virtual remote control and Web Dashboard Graphic engineering tool» Graphic engineering tool for the ETS 4» Zone concept: simple, fast setup/modification of rooms/ connections, as well as modification of parameters» Reduction of complexity due to the automatic generation of group addresses» Working with templates: reuse of created device and zone templates» utomatic generation of data for Web Dashboard, virtual remote control LIZ, BCnet objects for SCD (visualization) and trend data points BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

172 Newron 16 1) 2) 3) dogte utomation-server NEW For 1,000 data points Multi-Protocol Gateway that enables the integration of different protocols over TCP/IP in a Building Management System (BMS) and allows data exchange between the protocols. The integrated BCnet server offers scheduler, trend and alarm services. Data import of standard data bases (ETS for KNX, LNS for LON, EDE for BCnet) and MS Excel is supported. Enables decentralized IT structure. Redundancy: can be defined as backup device. Offers additional functions: virtual remote control and Web-Dashboard. Supports the protocols KNX, BCnet, LonWorks, Modbus, M-Bus. By default supported protocol/server: Modbus protocol and BCnet server. Optional 1 additional protocol: KNX, BCnet or LONWorks. Optional 2 additional protocols: KNX, BCnet or LONWorks. Optional 3 additional protocols: KNX, BCnet and LONWorks. For further information please contact central sales service of BB Busch-Jaeger Elektro GmbH. Rated voltage: V. Protection class (Device): IP 20. Temperature range (Device): 0 C to 55 C. Dimensions: (L x W x D): 252 mm x 199 mm x 33 mm. unit By default DGT-0-1K-B additional protocol DGT-1-1K-B additional protocols DGT-2-1K-B additional protocols DGT-3-1K-B dogte MOOVnGROUP license 3) For 100 devices Runtime license for MOOVnGROUP. For usage in combination with utomation-server dogte. unit DGT-MNG-100-B NEW dogte Web-Dashboard-VIS license 3) NEW For 1,000 data points Runtime license for Web-Dashboard-VIS. Web-Dashboard is a visualization based in the utomation-server dogate and allows to display/modify data points, trends, scheduler and alarms. Web-Dashboard supports HTML5 standard. Can be combined with all popular windows browsers. Web-Dashboard data s are automatically generated from the predefined MOOVn- GROUP zones. ll other dogte datapoints can be added manually. unit DGT-VIS-1K-B ) Scope of dogte services is managed by license keys. 2) Usage of, the into dogte integrated software on Windows PC is possible. 3) without picture 170 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

173 Newron dogte Virtual remote control-liz license 1) NEW For 100 zones Runtime license for virtual remote control-liz. For usage in combination with utomation-server dogte. Via LIZ rooms (zones) can be controlled by smartphone (ndroid, iphone) or PC widget. LIZ data s are automatically generated from the predefined MOOVnGROUP zones. The user makes a LIZ spatial control. The different rooms are enabled by passwords. unit DGT-LIZ-100-B dogte M-Bus protocol 1) dditional protocol for utomation-server dogte. Protocol: M-Bus. unit DGT-MBU-B NEW dogte OPC server 1) NEW Permits to bring data up to SCD/Visualization into OPC, from one or several dogtes. Runs on an external computer. unit DGT-OPC-B dogte MDRC Mounting kit 1) NEW For vertical or horizontal mounting of utomation-server dogte on mounting rail TS 35. unit DGT-DIN-B dogte Obix server 1) dditional Obix server for utomations-server dogte. Server: Obix. unit DGT-OBI-B NEW dogte Power supply 1) NEW Power supply for utomation-server dogte with main connection cable including connectors for various power outlets. Rated voltage: V~. Secondary: 19 V. Rated frequency: 47 Hz/63 Hz. unit DGT-PWR-B ) without picture BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

174 CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

175 ppendix Selection Table ccording to Order Code 174 Selection Table ccording to Type 189 B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

176 Selection Table ccording to Order Code Order code Type EN PG Page B K K K K K K K K K K K K K K K G G G G CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

177 Selection Table ccording to Order Code Order code Type EN PG Page K K K K K K K K K K K K K K K K K K K B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

178 Selection Table ccording to Order Code Order code Type EN PG Page B K G CDG110002R0011 S/M CDG110003R0011 J/M CDG110004R0011 J/M CDG110005R0011 BE/M CDG110006R0011 BE/M CDG110007R0011 BE/M CDG110008R0011 USB/S CDG110009R0011 DS/S CDG110012R0011 UD/M CDG110013R0011 ES/M CDG110014R0011 ES/M CDG110024R0011 SCM/S CDG110025R0011 DG/S CDG110026R0011 DG/S CDG110028R0011 J/S 4.SMI.1M CDG110029R0011 DR/S CDG110030R0011 E/S CDG110032R0011 WS/S CDG110034R0011 WZ/S CDG110058R0011 ES/S CDG110059R0011 ES/S CDG110060R0011 DSM/S CDG110061R0011 IPR/S CDG110065R0011 US/U CDG110066R0011 EUB/S CDG110067R0011 BDB/S CDG110070R0011 NTU/S CDG110071R0011 UK/S CDG110072R0011 BZ/S CDG110073R0011 BL/S CDG110074R0011 UD/S CDG110075R0011 XS/S CDG110079R0011 SD/S CDG110080R0011 SD/S CDG110081R0011 SD/S CDG110083R0011 ZS/S CDG110084R0011 FC/S 1.1M CDG110086R0011 E/ CDG110087R0011 LR/S CDG110088R0011 LR/S CDG110089R0011 LF/U CDG110090R0011 BE/S CDG110091R0011 BE/S CDG110092R0011 BE/S CDG110093R0011 BE/S CDG110094R0011 RM/S CDG110095R0011 RM/S CDG110096R0011 NTI/Z CDG110098R0011 IPS/S CDG110100R0011 S/M CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

179 Selection Table ccording to Order Code Order code Type EN PG Page 2CDG110101R0011 DLR/S M CDG110103R0011 DG/S CDG110104R0011 RC/ CDG110106R0011 RC/ CDG110107R0011 SD/M CDG110108R0011 LR/M CDG110109R0011 MT/S M CDG110110R0011 MT/S M CDG110111R0011 MT/U CDG110112R0011 S/S CDG110113R0011 S/S CDG110114R0011 S/S CDG110116R0011 V/S CDG110117R0011 V/S CDG110119R0011 TG/Z CDG110120R0011 JR/S CDG110121R0011 JR/S CDG110122R0011 JR/S CDG110124R0011 JR/S CDG110125R0011 JR/S CDG110126R0011 JR/S CDG110128R0011 JR/S CDG110129R0011 JR/S CDG110130R0011 JR/S CDG110131R0011 JR/S CDG110132R0011 S/S CDG110133R0011 S/S CDG110134R0011 S/S CDG110135R0011 TG/S CDG110136R0011 SE/S CDG110137R0011 S/S CDG110138R0011 S/S CDG110141R0011 FC/S CDG110142R0011 DGN/S CDG110143R0011 SJR/S CDG110144R0011 SV/S CDG110145R0011 SV/S CDG110146R0011 SV/S CDG110148R0011 EM/S CDG110150R0011 GM/ CDG110152R0011 S/S CDG110153R0011 S/S CDG110154R0011 S/S CDG110155R0011 S/S CDG110156R0011 S/S CDG110157R0011 S/S CDG110158R0011 S/S CDG110159R0011 S/S CDG110160R0011 S/S CDG110161R0011 S/S CDG110162R0011 S/S CDG110163R0011 FCL/S CDG110164R0011 FCL/S CDG110165R0011 RM/S CDG110166R0011 SV/S CDG110167R0011 SV/S CDG110168R0011 IO/S CDG110169R0011 IO/S CDG110170R0011 RM/S CDG110171R0011 LK/S CDG110172R0011 DLR/ CDG110174R0011 W/Z CDG110178R0011 MG/E B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

180 Selection Table ccording to Order Code Order code Type EN PG Page B 2CDG110180R0011 S/S CDG110181R0011 S/S CDG110182R0011 S/S CDG110183R0011 S/S CDG110184R0011 WZ/S CDG110186R0011 MG/ CDG110190R0011 E/S CDG110191R0011 WS/S CDG120001R0011 FC/S CDG120002R0011 TS/K CDG120004R0011 ST/K CDG120005R0011 /S CDG120006R0011 M/S CDG120007R0011 TS/K CDG120008R0011 TS/K CDG120009R0011 V/Z CDG120010R0011 V/Z CDG120011R0011 V/Z CDG120012R0011 V/Z CDG120032R0011 V/ CDG120033R0011 WES/ CDG120034R0011 ISM/S CDG120035R0011 ISS/S CDG120036R0011 IPM/S CDG120037R0011 CP-D 24/ CDG120038R0011 LGS/ CDG120039R0011 FW/S CDG120040R0011 FD/ CDG120041R0011 FG/ CDG120042R0011 PS/E CDG120043R0011 PK/E CDG120044R0011 HS/S CDG120045R0011 LFO/ CDG120046R0011 WES/ CDG120047R0011 EG/ CDG220003R0011 L240/MG CDG230013R0011 L240/IP CDG230014R0011 L240/PT CDG230017R0011 L240/ENG CDG230023R0011 IR/XB CDG230024R0011 IR/XC CDG230025R0011 EIM/XB CDG230026R0011 EIM/XC CDG230027R0011 IR/KB CDG230028R0011 EIM/KB CDG230029R0011 EIM/KC CDG230039R0011 EIM/D CDG240019R0011 SSM/ CDG240020R0011 SSM/U CDG250003R0011 WRK/W CDG280001R0011 BT/ CDG430051R0011 FC600/BREL CDG430073R0011 FC650/O CDG430081R0011 FC650/TMX CDG924003R0011 PS 1/4/6-KNX CDG924004R0011 PS 1/60/6-KNX CDL000001R0001 PS-END 1-S CL0N N BL CL0N N PL CL0N N N CL0N N BL CL0N N PL CL0N N N CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

181 Selection Table ccording to Order Code Order code Type EN PG Page 2CL0N N BL CL0N N PL CL0N N N CL0N N BL CL0N N PL CL0N N N CL0N N BL CL0N N PL CL0N N N CL0N N BL CL0N N PL CL0N N N CM100012R CM100013R CM100014R1000 C CM100143R CM100149R1000 B CM100150R1000 B CM100151R1000 B CM100152R1000 B CM100154R1000 B CM100155R1000 B CM100156R1000 B CM100163R1000 B CM100164R1000 B CM100165R1000 B CM100166R1000 B CM100168R1000 B CM100169R1000 B CM100170R1000 B CM100177R1000 B CM100178R1000 B CM100179R1000 B CM100180R1000 B CM100182R1000 B CM100183R1000 B CM100184R1000 B CM100191R1000 C CM100192R1000 C CM100237R CM100238R CM100240R CM100242R CM100244R CM100245R CM100248R CM100249R CM170500R CM170501R CM170502R CM170503R CM170504R CM170505R CM170506R CM170508R CM170510R CM170511R CM170512R CM170513R CM170514R CM170516R CM170520R CM170521R B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

182 Selection Table ccording to Order Code Order code Type EN PG Page B 2CM170522R CM170523R CM170524R CM170525R CM170526R CM170528R CM170529R CM170531R CM170532R CM170533R CM170534R CM170535R CM170536R CM170537R CM170538R CM170540R CM170541R CM170545R CM170546R CM170550R1000 C CM170554R CM170555R / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

183 Selection Table ccording to Order Code Order code Type EN PG Page / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

184 Selection Table ccording to Order Code Order code Type EN PG Page B / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

185 Selection Table ccording to Order Code Order code Type EN PG Page / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /UP / / /100 C /100 CB / / / /11 U B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

186 Selection Table ccording to Order Code Order code Type EN PG Page B /11 U /11 U /11 U /01 UP / / / / / / G / / / / U U U G G G G / / / G G G / /10-24G / / / / /30-24G / / CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

187 Selection Table ccording to Order Code Order code Type EN PG Page / / /38-24G / / / / /50-24G / / / / /58-24G / / / U U G G GM GM GM GM B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

188 Selection Table ccording to Order Code Order code Type EN PG Page B G G / / / / DGT-0-1K-B DGT-1-1K-B DGT-2-1K-B DGT-3-1K-B DGT-MBU-B DGT-OPC-B DGT-PWR-B CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

189 Selection Table ccording to Order Code Order code Type EN PG Page DGT-DIN-B DGT-OBI-B DGT-MNG-100-B DGT-VIS-1K-B DGT-LIZ-100-B / / / / /01 UP GHQ R0001 SGL GHQ R0001 SSF/G GHQ R0001 SSF/GB GHQ R0001 WEL/, ES GHQ R0001 WELT/, ES GHQ R0001 SCS GHQ R0001 L240/BS GHQ R0001 MRS/W GHQ R0002 MRS/B GHQ R0011 VMRS/W GHQ R0012 VMRS/B GHQ R0021 RTK GHQ R0001 L840/MG GHQ R0001 SD/GUP GHQ R0001 SD/ED GHQ R0001 SD/GP GHQ R0001 L208/V GHQ R0001 LKS GHQ R0004 SWM GHQ R0012 SWM4/RN GHQ R0001 LL/S GHQ R0002 NT/S GHQ R0002 NT/S GHQ R0005 MT 701.2, WS GHQ R0006 MT 701.2, SR GHQ R0011 T-RHM, WS GHQ R0012 T-RHM, SR GHQ R0014 UP-KST GHQ R0001 BUSKLEMME GHQ R0001 KLEMME GHQ R0001 VB/K GHQ R0002 VB/K GHQ R0003 VB/K GHQ R0004 VB/K GHQ R0001 KS/K GHQ R0011 KS/K GHQ R0001 US/E GHQ R0111 ER/U GHQ R0111 SU/S GHQ R0111 M/S GHQ R0111 US/U GHQ R0111 US/U GHQ R0111 US/U GHQ R0111 US/U GHQ R0111 LM/S GHQ R0111 JSB/S GHQ R0111 SMB/S GHQ R0003 EP GHQ R0004 ND/W GHQ R0011 ND/W GHQ R0021 NDU/W GHV V0021 FP GHV V0020 DB B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

190 Selection Table ccording to Order Code Order code Type EN PG Page B GHV V0021 DB GHV V0022 VSUE GHV V0004 GP GHV V0009 SPGS/W GHV V0010 SPGS/B GHV V0020 MW GHV V0020 MW GHV V0011 SK GHV V0011 SK GHV V0012 SK GHV V0013 SK GHV V0013 SK GHV V0001 ESPE GHV V0002 EVSB GHV V0003 MSE GHV V0004 MSP GHV V0001 SSS GHV V0100 RL CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

191 Selection Table ccording to Type Type Order code EN PG Page K K K K G K K K K K K K G K K K K K K K B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

192 Selection Table ccording to Type Type Order code EN PG Page B G K K K K K K K G K K K K K K K CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

193 Selection Table ccording to Type Type Order code EN PG Page G K K K / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

194 Selection Table ccording to Type Type Order code EN PG Page B 6123/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

195 Selection Table ccording to Type Type Order code EN PG Page 6126/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

196 Selection Table ccording to Type Type Order code EN PG Page B 6128/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /100 C /100 CB / / / /UP / / / /11 U /11 U /11 U /11 U / / / / /01 UP / / / CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

197 Selection Table ccording to Type Type Order code EN PG Page 6197/ / / / /10-24G / / / / /30-24G / / / / /38-24G / / / / /50-24G / / / / /58-24G / / / G G G G G / / / G G G B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

198 Selection Table ccording to Type Type Order code EN PG Page B / / / / U U U U G G U G G CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

199 Selection Table ccording to Type Type Order code EN PG Page GM GM GM GM / / /01 UP / / / / / / CM170554R CM170500R CM100240R CM170501R CM170502R CM170503R CM170504R CM170505R CM170506R CM100237R CM170508R B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

200 Selection Table ccording to Type Type Order code EN PG Page B CM170555R CM170510R CM100242R CM170511R CM170512R CM170513R CM170514R CM100238R CM170516R CM170520R CM100244R CM100245R CM170521R CM100012R CM170522R CM170523R CM170524R CM170525R CM170526R CM170528R CM170529R CM100143R CM170531R CM170532R CM170533R CM100248R CM100249R CM100013R CM170534R CM170535R CM170536R CM170537R CM170538R CM170540R CM170541R CM170545R CM170546R /S 4.1 2CDG120005R M/S 4.1 2CDG120006R BL/S 2.1 2CDG110073R BZ/S 2.1 2CDG110072R DB GHV V DB1 GHV V E/ 2.1 2CDG110086R E/S CDG110190R E/S 4.2 2CDG110030R M/S 12.1 GHQ R M50701-GR (6123/20-500) M50702-GR (6123/21-500) M50703-GR (6123/22-500) M50704-GR (6123/23-500) M50705-GR (6123/24-500) M50706-GR (6123/26-500) MD MD5153-G 104 MD5153-MG 104 MD5153-SB 104 MD5153-ST 104 MD5253-G 104 MD5253-MG 104 MD5253-SB 104 MD5253-ST 104 MD70053-N (6124/ ) CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

201 Selection Table ccording to Type Type Order code EN PG Page MD70153-N (6122/ ) MD72053-N (6125/ ) MD74053-N (6126/ ) MD76053-N (6129/ ) MD76153-N (6129/ ) MSE GHV V MSP GHV V B CM100149R B CM100150R B CM100151R B CM100152R B CM100154R B CM100155R B CM100156R B CM100163R B CM100164R B CM100165R B CM100166R B CM100168R B CM100169R B CM100170R B CM100177R B CM100178R B CM100179R B CM100180R B CM100182R B CM100183R B CM100184R BDB/S 1.1 2CDG110067R BE/M CDG110007R BE/M CDG110005R BE/M CDG110006R BE/S CDG110090R BE/S CDG110091R BE/S CDG110092R BE/S CDG110093R BT/ 1.1 2CDG280001R BUSKLEMME GHQ R C CM100014R C CM170550R C CM100191R C CM100192R CP-D 24/2.5 2CDG120037R DG/S 1.1 2CDG110026R DG/S CDG110103R DG/S 8.1 2CDG110025R DGN/S CDG110142R DGT-0-1K-B DGT-1-1K-B DGT-2-1K-B DGT-3-1K-B DGT-DIN-B DGT-LIZ-100-B DGT-MBU-B DGT-MNG-100-B DGT-OBI-B DGT-OPC-B DGT-PWR-B DGT-VIS-1K-B DLR/ CDG110172R DLR/S M 2CDG110101R DR/S 4.1 2CDG110029R DS/S CDG110009R B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

202 Selection Table ccording to Type Type Order code EN PG Page B DSM/S 1.1 2CDG110060R EG/ CDG120047R EIM/D 2CDG230039R EIM/KB 2CDG230028R EIM/KC 2CDG230029R EIM/XB 2CDG230025R EIM/XC 2CDG230026R EM/S CDG110148R EP GHQ R ER/U 1.1 GHQ R ES/M CDG110013R ES/M CDG110014R ES/S CDG110058R ES/S CDG110059R ESPE GHV V EUB/S 1.1 2CDG110066R EVSB GHV V FD/ 1.1 2CDG120040R FG/ 1.1 2CDG120041R FC/S 1.1 2CDG120001R FC600/BREL 2CDG430051R FC650/O 2CDG430073R FC650/TMX 2CDG430081R FC/S 1.1M 2CDG110084R FC/S CDG110141R FCL/S CDG110163R FCL/S CDG110164R FP03 GHV V FW/S CDG120039R GM/ 8.1 2CDG110150R GP2 GHV V HS/S CDG120044R IO/S CDG110168R IO/S CDG110169R IPM/S 1.1 2CDG120036R IPR/S 2.1 2CDG110061R IPS/S 2.1 2CDG110098R IR/KB 2CDG230027R IR/XB 2CDG230023R IR/XC 2CDG230024R ISM/S 5.1 2CDG120034R ISS/S 5.1 2CDG120035R J/M CDG110003R J/M CDG110004R J/S 4.SMI.1M 2CDG110028R JR/S CDG110129R JR/S CDG110120R JR/S CDG110124R JR/S CDG110130R JR/S CDG110121R JR/S CDG110125R JR/S CDG110128R JR/S CDG110131R JR/S CDG110122R JR/S CDG110126R JSB/S 1.1 GHQ R KLEMME GHQ R KS/K 2.1 GHQ R KS/K 4.1 GHQ R L208/V.24 GHQ R L240/BS GHQ R L240/ENG 2CDG230017R L240/IP 2CDG230013R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

203 Selection Table ccording to Type Type Order code EN PG Page L240/MG2 2CDG220003R L240/PT 2CDG230014R L840/MG4 GHQ R LF/U 2.1 2CDG110089R LFO/ 1.1 2CDG120045R LGS/ 1.1 2CDG120038R LK/S 4.2 2CDG110171R LKS GHQ R LL/S 1.1 GHQ R LM/S 1.1 GHQ R LR/M CDG110108R LR/S CDG110087R LR/S CDG110088R MG/ CDG110186R MG/E CDG110178R MRS/B GHQ R MRS/W GHQ R MT 701.2, SR GHQ R MT 701.2, WS GHQ R MT/S M 2CDG110109R MT/S M 2CDG110110R MT/U CDG110111R MW GHV V MW GHV V N N 2CL0N N BL 2CL0N N PL 2CL0N N N 2CL0N N BL 2CL0N N PL 2CL0N N N 2CL0N N BL 2CL0N N PL 2CL0N N N 2CL0N N BL 2CL0N N PL 2CL0N N N 2CL0N N BL 2CL0N N PL 2CL0N N N 2CL0N N BL 2CL0N N PL 2CL0N N2271 XX 111 N XX 111 N N2272 XX 111 N XX 111 N2273 XX 111 N XX 111 N2274 XX 111 N XX 111 N2371.9V 112 N XX 112 ND/W GHQ R ND/W GHQ R NDU/W GHQ R NT/S GHQ R NT/S GHQ R NTI/Z CDG110096R NTU/S CDG110070R PK/E 2.1 2CDG120043R PS 1/4/6-KNX 2CDG924003R PS 1/60/6-KNX 2CDG924004R B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

204 Selection Table ccording to Type Type Order code EN PG Page B PS/E 2.1 2CDG120042R PS-END 1-S 2CDL000001R RC/ 4.2 2CDG110104R RC/ 8.2 2CDG110106R RL GHV V RM/S 1.1 2CDG110094R RM/S 2.1 2CDG110095R RM/S 3.1 2CDG110165R RM/S 4.1 2CDG110170R RTK GHQ R S/M CDG110100R S/M CDG110002R S/S CDG110158R S/S CDG110162R S/S CDG110137R S/S CDG110138R S/S CDG110154R S/S CDG110183R S/S CDG110155R S/S CDG110159R S/S CDG110132R S/S CDG110112R S/S CDG110180R S/S CDG110156R S/S CDG110160R S/S CDG110133R S/S CDG110113R S/S CDG110152R S/S CDG110181R S/S CDG110157R S/S CDG110161R S/S CDG110134R S/S CDG110114R S/S CDG110153R S/S CDG110182R SD/ED GHQ R SD/GP GHQ R SD/GUP GHQ R SK12 GHV V SK17 GHV V SK17 GHV V SK7 GHV V SK7 GHV V SCM/S 1.1 2CDG110024R SCS GHQ R SD/M CDG110107R SD/S CDG110079R SD/S CDG110080R SD/S CDG110081R SE/S CDG110136R SGL GHQ R SJR/S CDG110143R SMB/S 1.1 GHQ R SPGS/B GHV V SPGS/W GHV V SSF/G GHQ R SSF/GB GHQ R SSM/ 2CDG240019R SSM/U 2CDG240020R SSS GHV V ST/K 1.1 2CDG120004R SU/S GHQ R SV/S CDG110144R CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

205 Selection Table ccording to Type Type Order code EN PG Page SV/S CDG110166R SV/S CDG110145R SV/S CDG110167R SV/S CDG110146R SWM 4 GHQ R SWM4/RN GHQ R TG/S 3.2 2CDG110135R TG/Z 1.1 2CDG110119R T-RHM, SR GHQ R T-RHM, WS GHQ R TS/K 1.1 2CDG120002R TS/K CDG120007R TS/K CDG120008R UD/M CDG110012R UD/S CDG110074R UK/S CDG110071R UP-KST 2 GHQ R US/E 1 GHQ R US/U CDG110065R US/U 2.2 GHQ R US/U 2.2 GHQ R US/U 4.2 GHQ R US/U 4.2 GHQ R USB/S 1.1 2CDG110008R V/Z CDG120009R V/Z CDG120010R V/Z CDG120011R V/Z CDG120012R V/ CDG120032R V/S CDG110117R V/S CDG110116R VB/K GHQ R VB/K GHQ R VB/K GHQ R VB/K GHQ R VMRS/B GHQ R VMRS/W GHQ R VSUE GHV V W/Z 1.1 2CDG110174R WEL/, ES GHQ R WELT/, ES GHQ R WES/ 2.1 2CDG120033R WES/ 3.1 2CDG120046R WRK/W 2CDG250003R WS/S 4.1 2CDG110032R WS/S CDG110191R WZ/S 1.1 2CDG110034R WZ/S CDG110184R XS/S 1.1 2CDG110075R ZS/S 1.1 2CDG110083R B BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

206 Notes 204 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

207 Notes BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

208 Notes 206 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

209 Notes BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015 2CDC500098C

210 Notes 208 2CDC500098C0202 BB i-bus KNX Smart Home and Intelligent Building Control Product Range Overview 2014/2015

211

212 Contact Further Information and Local Contacts: Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. BB G does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of BB G. Copyright 2014 BB ll rights reserved Order Number 2CDC500098C0202 printed in Germany (11/14-10-MMM)

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

ABB i-bus EIB / KNX Room Controller

ABB i-bus EIB / KNX Room Controller Product Information ABB i-bus EIB / KNX Room Controller Intelligent Installation Systems The Concept One Room Controller per Room The Room Controller consists of a basis device, into which up to 8 selected

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

The ABB i-bus KNX Room Master Concept Your first step into the KNX world The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,

More information

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................

More information

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2 Product Manual ABB i-bus EIB US/U 4.2 US/U 2.2 Intelligent Installation Systems Intelligent and limitless Contents Page 1 General............................................. 3 1.1 Product and functional

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S

ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S place picture here STO/GM/GS Juli 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S A Complete Range 15.11.2011 DESTO Jürgen Schilder 2 A Complete Range Switch Actuators are responsible for

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

KNX Lighting Control System

KNX Lighting Control System KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting

More information

ABB i-bus KNX IP Router IPR/S 2.1

ABB i-bus KNX IP Router IPR/S 2.1 Product Manual ABB i-bus KNX IP Router IPR/S 2.1 Intelligent Installation Systems This manual describes the function of the IP Router IPR/S 2.1 with the application program IP Routing. Subject to changes

More information

ABB i-bus EIB / KNX Weather Station WS/S 4.1

ABB i-bus EIB / KNX Weather Station WS/S 4.1 Product Manual ABB i-bus EIB / KNX Weather Station WS/S 4.1 Intelligent Installation Systems This manual describes the function of the Weather station WS/S 4.1. Subject to changes and errors excepted.

More information

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject

More information

KNX-Flash ABB i-bus KNX

KNX-Flash ABB i-bus KNX KNX-Flash ABB i-bus KNX Exclusion of liability: Despite checking the contents of this document deviations cannot be completely excluded. We therefore cannot accept any liability for this. KNX-Flash Inhaltsverzeichnis

More information

Transmitter Actuator 230V wave UP 560. Operation

Transmitter Actuator 230V wave UP 560. Operation Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for

More information

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Logic Module LM/S 1.1 Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...

More information

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Product Manual ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Intelligent Installation Systems This manual describes the function of the Switch

More information

ABB i-bus KNX Application Manual Lighting

ABB i-bus KNX Application Manual Lighting Application Manual Lighting Description of the symbols: Sample Note Tip Disadvantage Advantage Table of content Table of content Page Preface/ General... 3 1. Introduction 1.1. Basic control types...5

More information

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with

More information

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145 KNX system units The system components are KNX devices, which assume higher-level functions, independent of the application. They guarantee the necessary infrastructure in the building, ensuring a flawless

More information

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions

More information

Passion for KNX innovation

Passion for KNX innovation Passion for KNX innovation Touch-MyDesign 2 Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building thanks to its total customization: Everyone can

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

Technology of Choice Smart Home and Intelligent Building Control ABB i-bus KNX

Technology of Choice Smart Home and Intelligent Building Control ABB i-bus KNX Technology of Choice Smart Home and Intelligent Building Control ABB i-bus KNX Contents KNX and ABB i-bus KNX 4 What does KNX stand for? 5 What does KNX do? 6 ABB i-bus KNX 7 Energy efficiency with ABB

More information

Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System

Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System Audio Audio actuator 4fold 0531 00 Audio actuator 4fold Audio actuator mono Audio actuator stereo Communication Infrared 0588.. IR converter IR transmission/reception C00701 Radio 0868 00 Radio-instabus

More information

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com Aus- und Weiterbildung GmbH Home and Building Control KNX / EIB www.elabo-ts.com Design and commissioning of KNX/EIB systems www.elabo-ts.com Hardware page 2-5 Software page 6-9 Projects page 10-15 LOGO!

More information

Unica for KNX system 226

Unica for KNX system 226 Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from

More information

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes

More information

ABB i-bus KNX DALI-Gateway DG/S 8.1

ABB i-bus KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes Dynamic

More information

Product Range Overview 2002. ABB i-bus EIB. Intelligent Installation Systems

Product Range Overview 2002. ABB i-bus EIB. Intelligent Installation Systems Product Range Overview 2002 ABB i-bus EIB Intelligent Installation Systems Product Range Overview Contents Page Introduction................................................ 2 Power Supplies.............................................

More information

KNX Powerline PL 110. KNX Association

KNX Powerline PL 110. KNX Association KNX Powerline PL 110 Table of Contents 1 Introduction...3 2 Standardisation...3 3 Transmission Process...4 3.1 Phase Coupling...5 3.2 Telegram Transmission...6 3.2.1 Training Sequence...6 3.2.2 Preamble

More information

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx 756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX Data Logging Unit BDB/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the Data Logging Unit BDB/S 1.1. Subject to changes and errors excepted.

More information

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S 2.300.2. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX Universal Dim Actuator, MDRC UD/S 2.300.2 Intelligent Installation Systems ABB UD/S 2.300.2 Universal Dim Actuator, MDRC This manual describes the function of the Universal

More information

Basics of Dimming. ISC Learning Centre

Basics of Dimming. ISC Learning Centre ISC Learning Centre July 2009 > Dimmers Contents What is a dimmer? Dimmers & customer benefits Dimmers at home Dimmers at the office Dimmers: technical choices Overview of the Schneider Electric offer

More information

ABB i-bus KNX i-bus Tool Product Information

ABB i-bus KNX i-bus Tool Product Information ABB i-bus KNX i-bus Tool Product Information A professional Service Tool for System Integrators ABB presents a fully new and innovative software concept with the i-bus Tool. It supports system integrators

More information

Light scene push button 8gang comfort flush-mounted 751688xx

Light scene push button 8gang comfort flush-mounted 751688xx 751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

Busch-Watchdog Presence EIB Type: 6131-74-102-500

Busch-Watchdog Presence EIB Type: 6131-74-102-500 Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value

More information

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111 , GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the

More information

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program

More information

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : [email protected] Unit compliant with the requirements of directives:

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

ABB i-bus KNX Security Solutions with KNX Security Terminal Product Information

ABB i-bus KNX Security Solutions with KNX Security Terminal Product Information ABB i-bus KNX Security Solutions with KNX Security Terminal Product Information Compact Security Solutions for the ABB i-bus KNX the New Security Terminals from ABB The compact solution for security applications

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual

ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual ABB i-bus KNX Security Terminals MT/U 2.12.2, MT/S 4.12.2M and 8.12.2M Product Manual Contents Contents Page 1 General 3 1.1 Use of the product manual...3 1.1.1 Structure of the product manual...3 1.1.2

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

Niko Home Control. Installation Manual

Niko Home Control. Installation Manual Niko Home Control Installation Manual Niko Home Control: Table of contents Warnings regarding installation...2 Guarantee provisions...3 CE...4 Key of symbols...5 1. Installation preparations...6 2. Controller...8

More information

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems KNX Gateway Light-Control R User manual-ver.1 LC-IPGW-001 Intelligent Installation Systems Contents 1. Summary ---------------------------------------------------------------------------------------------------------------------

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

Technical Manual MDT Rain sensor

Technical Manual MDT Rain sensor 9/2012 Technical Manual MDT Rain sensor SCN-RS1R1.01 Technical Manual Rain sensor SCN RS1R1.01 1.1. Settings at the ETS Software Selection at the product database: Manufacturer: MDT Technologies Product

More information

Tebis application software

Tebis application software Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ

More information

Charge Controller CC611/CC612 Preliminary datasheet

Charge Controller CC611/CC612 Preliminary datasheet Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Product description The ender charge controller CC611 is the main component of a charging point and is designed for

More information

ABB i-bus KNX. Room Solutions. ABB STOTZ-KONTAKT GmbH - 2CDC 514 049 N0202, page 1

ABB i-bus KNX. Room Solutions. ABB STOTZ-KONTAKT GmbH - 2CDC 514 049 N0202, page 1 ABB i-bus KNX Room Solutions 2CDC 514 049 N0202, page 1 Room Master RM/S x.1 The Room Master RM/S 1.1 and RM/S 2.1 offers smart home and intelligent building control for hotel rooms and apartments Modern

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1 Product Manual ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1 Intelligent Installation Systems This manual describes the function of the 1-fold DALI-Gateway with its application programs Dim Light Scenes Dynamic

More information

SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING

SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING AUTOMATION SYSTEM Catalogue SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING automation system Contents 4-11 Catalogue Control devices 4 Sensors 5 Modular controllers 6 False ceiling controllers and Automation

More information

KNX Panasonic Air Conditioners

KNX Panasonic Air Conditioners IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line

More information

Highly flexible the right KNX/DALI gateway for every requirement

Highly flexible the right KNX/DALI gateway for every requirement The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with

More information

Building Technologies

Building Technologies Building Technologies RXB room automation system System overview Contents Comfort and well-being in every room...5 Range overview...6 Coordinated room controllers...7 The room units: the key to individual

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

EIB/KNX IP Interface with Power over Ethernet (PoE)

EIB/KNX IP Interface with Power over Ethernet (PoE) EIB/KNX IP Interface with Power over Ethernet (PoE) IP Interface between LAN and EIB/KNX bus (Quelle: EIBMARKT GmbH, Reference No.: N000401) Page 1 Application area The KNXnet/IP-Interface is used to connect

More information

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light In this issue, we would like to present the EnOcean radio sensor module STM 110 in more detail. The module

More information

HDL KNX / EIB BUS. Switch Actuators. Guangzhou Hedong Electronic Co.,Ltd (HDL) 1/50

HDL KNX / EIB BUS. Switch Actuators. Guangzhou Hedong Electronic Co.,Ltd (HDL) 1/50 Guangzhou Hedong Electronic Co.,Ltd (HDL) 1/50 HDL KNX / EIB-BUS (Intelligent Installation Systems) Product Manual Contents 1 General..4 1.1 Product Function... 5 2 H a r d w a r e. 6 2.1 Technical data...6

More information

Push button 3gang standard flush-mounted 751633xx

Push button 3gang standard flush-mounted 751633xx Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard

More information

The application is now available in 8 languages. (German, English, French, Spanish, Italian, Russian, Dutch, Polish)

The application is now available in 8 languages. (German, English, French, Spanish, Italian, Russian, Dutch, Polish) Product: Room Master, Premium Type: RM/S 2.1 Current application program: Room Master, Premium/2.5a ======================================================================================= to: Room Master,

More information

ABB i-bus KNX Application Manual Security in Buildings

ABB i-bus KNX Application Manual Security in Buildings Application Manual in Buildings Contents Contents 1 General... 3 1.1 Application manual ABB i-bus KNX in buildings...3 2 Introduction... 5 2.1 Standards and norms...5 2.1.1 German standards and norms...5

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications The ZigBee Plug & Play wireless Network for Building and Industrial Applications Energy Management Renewable Monitoring Environment Monitoring Open Modbus Integration Products Range Overview Products Range

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module

More information

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S 1.16.1 Product Manual

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S 1.16.1 Product Manual DALI Gateway Emergency Lighting DGN/S 1.16.1 Product Manual Contents Contents Page 1 General... 3 1.1 Product and functional overview... 4 1.2 DALI general... 6 1.3 ABB i-bus DALI gateways in comparison...

More information

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com Gateway KNX-DALI DALIX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Power Line Carrier technology

Power Line Carrier technology Power Line Carrier technology To be used in new or renovated traditional installation (L+ required) up to 00 m SIMPLE TO ISTLL FOR MXIMUM COMFORT PLC technology, which systematically includes neutral,

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information