Control and signalling units Ø 22
|
|
|
- Kathleen Davidson
- 9 years ago
- Views:
Transcription
1 pages /0 to /3 pages /4 to /53 pages /54 to /6 General Description The Ø 22, style 4 range of control and signalling units comprises : Complete units XB4-B Pushbuttons Pilot lights Sub-assemblies for user assembly ZB4-B Pushbuttons: Pilot lights : Head and body sub-assemblies Head and body sub-assemblies Component parts and accessories ZB /2 Te
2 pages /0 to /3 pages /4 to /53 pages /54 to /6 Schematic library Pushbuttons and Emergency stop pushbuttons Pushbutton Pushbutton Mushroom head, Emergency stop latching N/O contact N/C contact mushroom head. Push-pull N/O contact N/C contact Emergency stop trigger Emergency stop trigger Emergency stop trigger Emergency stop trigger action mushroom head action mushroom head action mushroom head action mushroom head Push-pull Turn to release - N/C contact Key release - N/C contact Turn to release Emergency stop trigger action mushroom head Key release Double headed pushbutton Selector switches Selector switch - 2 position, Selector switch - 3 position, Selector switch - 3 position, Selector switch - 2 position, stay put stay put 2 to centre stay put, key withdrawal LH N/O contact N/O + N/O contact N/O + N/O contact position - N/O contact 2 Selector switch - 2 position, from right to left, key withdrawal LH position N/O contact Pilot lights IN DEL IN 230 V c 6 V Pilot light with BA 9s LED pilot light Pilot light with integral transformer, 0/20 V c primary, incandescent bulb 6 V secondary BA 9s incandescent bulb Illuminated pushbuttons and selector switches IN 250 V max. Illuminated pushbutton Illuminated pushbutton Illuminated pushbutton Double-headed pushbutton BA 9s incandescent bulb LED with integral transformer, with LED pilot light 0/20 c 50/60 Hz primary, 6 V secondary. LED 2 BA 9s incandescent bulb Illuminated selector switch LED - 2 position stay put LED IN 20 V c 6 V Joystick controllers 2 direction 4 direction D LED D A 0 B A 0 B A 0 B A 0 B C C Without With Without With spring return Te /3
3 pages /0 to /3 pages /4 to /53 pages /54 to /6 Complete units, XB4-B General Complete units ready for mounting Contact functions Pushbuttons, Flush push XB4-BAi/BA42 XB4-BA33 XB4-BA4322 see page /4 see page /4 see page /4 Booted flush push Projecting push Mushroom head XB4-BPi/BP42 XB4-BL42 XB4-BC2 see page /4 see page /4 see page /4 Double-headed pushbuttons, Flush push + projecting push Booted flush push + projecting push XB4-BL845 XB4-BL945 see page /4 see page /4 Ø 40 Emergency stop and mushroom head pushbuttons without/with trigger action Push-pull Turn to release Key release XB4-BT42/BT845 XB4-BS542/BS8445 XB4-BS42/BS9445 see page /5 see page /5 see page /5 Selector switches and key switches /4 Te Standard black handle Long black handle Key switches XB4-BD XB4-BJ XB4-BG see page /5 see page /5 see page /5
4 pages /0 to /3 pages /4 to /53 pages /54 to /6 Complete units, XB4-B Complete units ready for mounting Signalling functions Pilot lights With integral LED For BA 9s bulb Direct supply Via integral transformer XB4-BVB/BVG/BVM XB4-BV6 XB4-BV3/BV4 see page /6 see page /7 see page /7 Combined contact and signalling functions Illuminated pushbuttons,, flush push With integral LED For BA 9s bulb Direct supply Via integral transformer XB4-BW3iB5/BW3iG5/BW3iM5 XB4-BW3i65 XB4-BW3i35/BW3i45 see page /8 see page /8 see page /9 Double-headed pushbuttons,, with pilot light With integral LED XB4-BW84i5 see page /9 Illuminated selector switches, standard handle With integral LED XB4-BK2iB5/BK2iG5/BK2iM5 see page /9 Te /5
5 pages /0 to /3 pages /4 to /53 pages /54 to /6 Sub-assemblies, ZB4-B General Non illuminated units for user assembly Contact functions Body sub-assemblies Pushbuttons,, without marking ZB4-BZ0i/BZ4 see page /20 Flush push Flush push Flush push Flush push for without cap with set of insertion of legend 6 colour caps ZB4-BA0 ZB4-BA9 ZB4-BAi ZB4-BAi8 see page /2 see page /2 see page /2 see page /2 Plug-in connector ZB4-BZ0i4/BZ44 see page /20 Projecting push Recessed push Booted flush push Booted flush push for insertion of legend ZB4-BLi ZB4-BAi6 ZB4-BPi ZB4-BPi8 see page /2 see page /2 see page /2 see page /2 Pushbuttons,, with marking Flush push Projecting push ZB4-BAi3i/i4i ZB4-BLi3i ZB4-BA334/335 see page /22 see page /22 Push-push to release pushbuttons Flush push Projecting push ZB4-BH0i ZB4-BHi see page /22 see page /22 Double-headed pushbuttons, Flush pushes (IP 40/IP 66) Flush push + projecting push (IP 40/IP 66) Without/with markings Without/with markings ZB4-BA8 ZB4-BA9 ZB4-BL83 ZB4-BL93 ZB4-BA82 ZB4-BA92 ZB4-BL84 ZB4-BL94 see page /23 see page /23 see page /23 see page /23 /6 Te
6 pages /0 à /3 pages /4 à /53 pages /54 à /6 Sub-assemblies, ZB4-B Non illuminated units for user assembly (continued) Contact functions Body sub-assemblies Mushroom head pushbuttons, Spring return ZB4-BC/BR ZB4-BZ0i/BZ4 see page /24 see page /20 Ø 30 Ø 40 Ø 60 Mushroom head pushbutons, latching with or without trigger action Ø 40 Ø 60 Ø 30 Ø 40 Ø 60 Push-pull Turn to release ZB4-BT84 ZB4-BTi/BXi ZB4-BS8i4 ZB4-BS4i/BS5i/BS6i Plug-in connector see page /25 see page /25 ZB4-BZ0i4/BZ44 see page /20 Ø 30 Ø 40 Ø 60 Key release ZB4-BS9i4/BS7i/BSi/BS2i see page /25 () Switch handle (2) Key withdrawal and knob positions positions for key Selector switches switches and key switches Key withdrawal positions Std. black handle () Long blk. handle () ZB4-BD ZB4-BJ see page /26 see page /26 Knurled blk. knob () Key switches (2) ZB4-BDi9 ZB4-BG see page /26 see page /27 Toggle switches 2 positions ZB4-BDi8 see page /52 Te /7
7 pages /0 to /3 pages /4 to /53 pages /54 to /6 Sub-assemblies, ZB4-B Pilot lights for user assembly Signalling units Body sub-assemblies Integral LED With lens mounted ZB4-BV0i3 see page /29 ZB4-BVB/BVG/BVM see page /28 Plug-in connector With 5 separate lenses not mounted ZB4-BVBi4/BVGi4/BVMi4 ZB4-BV003 see page /28 see page /29 Body sub-assemblies for BA 9s bulb With lens mounted ZB4-BV0i see page /29 Direct supply ZB4-BV6 see page /29 Via integral transformer ZB4-BVi/BV3Di /BV5Di see page /29 /8 Te
8 pages /0 to /3 pages /4 to /53 pages /54 to /6 Sub-assemblies, ZB4-B Illuminated pushbuttons and selector switches for user assembly Illuminated pushbuttons, Combined contact and signalling functions Body sub-assemblies Integral LED Flush push Flush push with Flush push for insertion illuminated ring of legend ZB4-BW3i3 ZB4-BW9i3 ZB4-BAi8 see page /35 see page /35 see page /35 ZB4-BW0B/BW0G/ BW0M see pages /30 et 3 Double headed pushbuttons,, with pilot light Booted Projecting push flush push ZB4-BW5i3 ZB4-BWi3 see page /35 see page /35 Plug-in connector ZB4-BW0Bii ii4/ BW0Gii ii4/bw0mii see pages /32 et 5 Illuminated push-push to release pushbuttons and illuminated selector switches with standard handle Flush pushes Flush push + projecting push Without/with markings Without/with markings ZB4-BW8iii3, ZB4-BW82iii3 ZB4-BW83iii3, ZB4-BW84iii3 see page /36 see page /36 see page /36 see page /36 Flush or projecting Selector switches with push-push to release standard handle ZB4-BH0i3/BHi3 ZB4-BKii3 see page /36 see page /37 Body sub-assemblies For BA 9s bulb Illuminated pushbuttons, Direct supply ZB4-BW06 see page /34 Flush push ZB4-BW3 see page /35 Projecting push ZB4-BW see page /35 Via integral transformer ZB4-BW03/4/5/3D/5D see page /34 Te /9
Switches and Indicators. Swisstac
Switches and Indicators Switches and Indicators Index Series Description Page 583 Product Assembly Page 584 Mounting Instruction Page 585 Product Range - pushbuttons for standard mounting - pushbuttons
Pendant control stations 6
References Empty enclosures 0 XACA0 Empty enclosures Description Enclosure comprising: - the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring,
Pendant control stations 6
Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications
Pilot and Signaling Devices. Section 9. www.geindustrial.com Control Catalog 9-1
The GE push button offering includes a complete line of control units and stations in both full size (30 mm) push buttons and in smaller size (22 mm) devices which are designed to be used in numerous types
Control and Signaling Units
Control and Signaling Table of Contents Page Specifications... 3 Constructions Characterisitics... 3 Ordering Guide... 4 Pushbutton... 5 Double Pushbutton... 6 Emergency (Mushroom Head)... 6 Selector...
9 Control Equipment. Control Button Series 8082
9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements
References Control and signalling units Ø 22 0
Merlin Gerin Modicon Square D Telemecanique References To combine with heads, see pages 36060-EN_ er4.0/2 to 36067-EN_er3.0/2 Body/contact assemblies - Screw clamp terminal connections 814264 Body/fixing
Series. Catalogue. www.eao.com
Series 45 Catalogue www.eao.com Expert manufacturers. EAO creates possibilities. Since 1947. Founding year: 1947 Number of employees: 600 Headquarters: Olten, Switzerland Manufacturing Companies: Switzerland,
HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.
Edition 02/2016 HMI s Series Characteristics The compact Series is especially suited for: Functions The Series incorporates the following functions: Market segments The EAO series is used in the following
SPARES & ACCESSORIES. FLAMEPROOF Ex-d Components. IP rating Ambient temperature range Approvals. Marking. Barrel thread
FLAMEPROOF Ex-d Components Ex-d components are available in a wide range of operators/pilot lights PL series and selectors PSRC series; allow numerous combinations with our CP../CPS.. EFDCN/EFSRC series.
Mureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
Commanding and Signaling Devices
Commanding and Signaling Devices Introduction Overview 3SB2 3SB30, 3SB32 3SB31, 3SB33 3SB35, 3SB36 Pushbutton units and indicator lights Designs Nominal diameter 16 mm 22 mm 22 mm 22 mm Plastic, round
Safety dialogue solutions
General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which
INDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA 01835-0788 TOLL FREE: (877) 246-7890 FAX: (781) 245-4531 E-mail: info@apem.
INDUSTRIAL CONTROLS INDUSTRIAL CONTROLS E INDUSTRIAL CONTROLS SELECTION GUIDE Series Description Page A01 & A02 Products & Features 2 A01 & A02 Specifications 3 A01 Illuminated or non-illuminated pushbutton
Electro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
Motor circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors
Notes on Product Changeover
13 13/2 Notes on Product Changeover Introduction 13/3 Devices for delivery over the long term 13/4 devices with a mounting depth of 55 mm 13/5 devices with a mounting depth of 55 mm 13/15 devices with
Switches SWITCHES SWITCHES
Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile
ø22mm HW Series Control Units
mm HW Series Control Units HW Series Control Units (Selection Guide) Function Emergency Stop Switch (Unibody Type) Emergency Stop Switch (Separate Type) Pushlock Turn eset Category ø40mm Mushroom ø40mm
COMMERCIAL GAS DRYER
COMMERCIAL GAS DRYER MODELS CGM2941TQ0 CGM2941TQ1 07 08 Litho in U.S.A. (LT)(mek) c 2008 WHIRLPOOL CORPORATION Part No. Rev. B BULKHEAD PARTS (White) (White) 2 BULKHEAD PARTS 1 Literature Parts 8563800
COMMERCIAL GAS DRYER
COMMERCIAL GAS DRYER MODELS CGM2751TQ0 (WHITE) CGM2751TQ1 (WHITE) 5 12 Litho in U.S.A. (CMS) (psw) c 2012 WHIRLPOOL CORPORATION Part No. W10119631 Rev. C TOP AND CONSOLE PARTS W10119631 2 TOP AND CONSOLE
Line-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: 2000 9105.RAVI. Pendant Stations LADY Series
C E R T I F MA N A G E ME N T I E D Net ISO 9001: 2000 9105.RAVI I S Y S T E M Pendant Stations LADY Series 4.1 Pendant Stations LADY Series - LA type single-row Main Features The new LADY series single-row
CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.
CHAPTER 5 PARTS PARTS BY PICTORIAL This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation. NOTE: The following is a breakdown description of the
Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.
2010-2011 Solutions for appliance & electronic applications Shortform Catalogue rocker lever push vandal resistant slide door snap-action & safety rotary IEC sockets fuseholders indicators A trading name
CutMaster 102. 6.04 Major External Replacement Parts
CutMaster 0 6.04 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-086 Tube, roll handle 9-0 4 Front Panel 9-087 Rear Panel 9-00 4 Art #
COMPALARM AP GENERAL MAIN FEATURES
GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright
2 WIRE video door entry system
J J N P CLASSE 00 VE WIRE video door entry system 5 Description Front view WIRE handsfree colour video handset with inductive loop, preset for different types of installations, depending on the accessories
Switches & Pilot Devices
Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action
Operating Instructions Bedienungsanleitung Mode d emploi
Operating Instructions Bedienungsanleitung Mode d emploi DW 400 www.bron-kobold.com Operating instructions DW 400 Before use Please read all the information contained in these operating instructions carefully.
Original Assembly Guide
TCT Multipurpose Single Bevel Sliding Compound Mitre Saw Original Assembly Guide Read instructions before assembling this tool. Table of Contents GB Assembly Guide Read instructions before assembling this
Control blocks for two-hand start ZSB
Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for
Reaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
How To Use A Iphone With A Color Capoi
CD16 SIGNAL AND CONTROL COMPONENTS GENERAL INFORMATIONS INFORMAZIONI GENERALI R 0,8 max 1,7 17,9 24 ø 16 ø 16 24 23 SIGNAL AND CONTROL COMPONENTS CD16 PUSHBUTTONS AND PILOT LIGHTS PULSANTI E SEGNALATORI
Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting
Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters
SECTION 3A (Rev.F) SECTION CONTENTS. Download from www.urmet.com Technical Manuals area. sec.3a INSTALLATION...9 TECHNICAL SPECIFICATIONS...
SECTION 3A (Rev.F) Apartment door phone stations Download from www.urmet.com Technical Manuals area. ATLANTICO DOOR PHONES 2 TECHNICAL SPECIFICATIONS...2 4+n wire system door phones...2 Door phone with
Assembling an AR-15 Parts CheckList:
Assembling an AR-5 Parts CheckList: Table of Contents Upper Receiver Common Parts... A, A2 & A3 sights... 2-3 BARREL COMPONENTS... 4-5 BOLT & BOLT CARRIER COMPONENTS... 6 LOWER RECEIVER COMMON PARTS...
SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions
SET3M electro-mechanical 24 programmer for heating & hot water Installation & User Instructions Index Installation Product specification 3 Installation 4-5 Wiring 6-12 Replacement 13-15 User Your programmer
design New products 14
design WITH LED. New products 14 4 6 7 10 24 12 13 16 28 18 19 22 30 COMPANY METRON Inspiration Innovation Product SPYKE Inspiration Innovation Product LUNIK Inspiration Innovation Product RIBAG Licht
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4
TABLE OF CONTENTS A Adjustable Angle Bracket (294/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)... 7 C Coordinator Mounting Bracket (2950 Series)... 7 Concealed Magnetic
THE ADVANTAGES ARE YOURS
THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many
7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
PHA 2000 PHB 3000 EXIT PAD
PHA 2000 PHB 000 EXIT PAD Panic Hardware in Contur Design PHA 2000 PHB 000 EXIT PAD THE MODULAR PANIC HARDWARE-SSTEM IN CONTUR DESIGN Prior knowledge of how to open the escape door is not expected. DANGER
Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
Series VM. Mechanical Valves VM200. VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25
Mechanical Valves Series VM Model Dimensions (mm) VM1000 Side ported 11 x 36 x 16 Bottom ported 11 x 28 x 25 VM100 Side ported 17 x 44 x 25 Bottom ported 17 x 44 x 30 VM200 25 x 40 x 52 One way roller
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) 1268 563720. www.mkelectric.com IP66. Improved catch.
Masterseal Plus TM technical hotline +44 (0) 268 63720 Improved catch Rear drill holes Available in grey, white and black Fixed gasket speds installation gasket Now has all the features and logic plus
CutMaster 82. 6.04 Major External Replacement Parts
CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080
Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-652 RETURN TO MAIN INDEX PARTS LIST FOR Flextec 450 P-652 P-652-A P-652-A ILLUSTRATION
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves
U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking
Stop Alert Flasher with G-Force sensor
Stop Alert Flasher with G-Force sensor Stop Alert module creates brake light flashing effect to catch attention of the drivers behind to avoid dangerous rear end collision. The flasher module is a state
General 1-2-Opto-electronics Safety Switches 4-Emergency
General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a
Short Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
ConSig 8040 Series CONTROLS. 8040 Features:
ConSig 8040 Series CONTROLS CONTROL & SIGNALING STATIONS 8040 Features: Attractive space efficient design. A variety of enclosure sizes made of Fiberglass Reinforced Polyester (FRP). Snap-on mounting of
Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.
Schematic symbols are used to identify and graphically depict the function of fluid power components. Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.
MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB
MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP
Bulb Replacement REPLACING BULBS WARNING
Bulb Replacement REPLACING BULBS Check the operation of all exterior lamps before you drive the vehicle. Caution: Before attempting to replace a bulb, ensure that both the affected lamp and the vehicle's
COMMERCIAL GAS DRYER
COMMERCIAL GAS DRYER MODELS CGD8990XW0 4 12 Litho In U.S.A. (CMS) (psw) c 2012 WHIRLPOOL CORPORATION Part No. Rev. B TOP AND CONSOLE PARTS 2 TOP AND CONSOLE PARTS 1 Literature Parts W10184516 Installation
Comparison of NEMA and IEC schematic diagrams
Cross-Reference MZ081001EN Comparison of NEMA and IEC schematic diagrams General With the increasing emphasis on globalization, many industries are now looking to all parts of the world to produce, market,
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Lighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
Safe switching and monitoring Solenoid Interlocks
Safe switching and monitoring Solenoid Interlocks Solenoid locking switches are used on sliding, hinged and removable guard doors that must be closed and locked for operator safety. It is a two part system
INSTALLATION INSTRUCTIONS: Viewline 85 mm
1-10 1 Safety information The product was developed, manufactured and inspected according to the basic safety requirements of EC Guidelines and state-of-the-art technology. The unit is designed for use
Section M POWER LIFTS
Section M POWER LIFTS December 2009 1M Index 1. 53-520244-000 Poly V Idler Assembly 2. 53-520205-000 N.A. Mounting Bracket 3. 53-520212-000 Cable Assembly 4. 53-600149-000 Wire Harness Assembly 5. 53-860322-010
GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847 673-5009 email@gaertnerscientific.
7109-C-244E-R1 Field Installation of HeNe Laser in B, C, and D-Type Auto Gain Ellipsometers GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois 60076 U.S.A. tel: 1 847 673-5006 fax: 1 847
photoelectric highlights www.automation.datalogic.com
photoelectric miniature sensors S8 series The new S8 series of compact sensors offers excellent detection performances, usually associated with sensors that have larger dimensions and a higher price. The
Electro-Pneumatic Bus Door Control Mechanism
Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with
WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE
INSTRUCTIONS Product: GEM Electric Motorcars Models: All Subject: Instructions for installing Stereo Accessory Estimated Completion Time:.75 Hours Parts: See Page # 7 REQUIRED TOOLS & SUPPLIES: (1) 3/8
Solid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : [email protected] Solid-State Timer Low-Cost, Plug-In
MONO BLOCK DIRECTIONAL CONTROL VALVE TS
SHIPPING: 2332 S 25TH STREET (ZIP 6815) MAILING: P.O. BOX #669 OMAHA, NE 6816 PHONE: (42) 344-4434 FAX: (42) 341-5419 HTTP://WWW.BRAND-HYD.COM MONO BLOCK DIRECTIONAL CONTROL VALVE TS TS312TSDTSTKJB TS2
FSLIMRF05-10 - 15-20 - 25
1. INTRODUCTION FSLIMRF is a fully wireless, battery-powered infrared beam barrier for the protection of doors and windows with alarm radio transmission. The barrier is made up of two aluminium sections
1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions
Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
ALBINS SEQUENTIAL SHIFTER
ALBINS SEQUENTIAL SHIFTER Updated 12/11/11 8-AGB5-INST GENERAL NOTES The Albins Sequential Shifter is specifically designed for AGB transaxles. It features an integral reverse lockout lever and has a position
225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
LUT Luminescence scanners: Seeing what no-one else can
LUT Luminescence scanners Luminescence scanners LUT Luminescence scanners: Seeing what no-one else can Special features: A semi-conductor light source is used in the LUT series no lamp change required.
Manual Switches Series 2 Pushbutton Switches and Indicators
BARRIER MOUNT Display screen (page 115) Mounting barrier (next page) Housing (next page) FEATURES Easy-to-assemble modules provide thousands of display/control combinations Up to 4 incandescent lamps 1,
Guide rail bracket (for adjustable heads)
(for adjustable heads) Part. 209 40 ø,5 ø10,5 2 2,5 115 15 42 5 11 37 72 4 70 Code 209 / 0754 MATERIALS: Bracket made out of reinforced polyamide black colour. FEATURES: To be used with heads Part.221,
Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems
WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
Decorative Metal Wiring Accessories in Assorted Plate Finishes
Decorative Metal Wiring Accessories in Assorted Plate Finishes Switches Power Socket Outlets 13A Fused Connection Units Control Switches TV Telephone Data Sockets Deco unique product codes Decorative Metal
225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.
Page 7-6 and 9 7-22 and 25 DOUBLE AND TRIPLE TOUCH ACTUATORS Ø22mm Double touch with or without indicator Triple touch. Page 7-26
Page -4/5/8-20/21/24 BUTTON ACTUATORS Ø22mm Spring return flush, extended and shrouded Push-push flush and extended Mushroom-head Mechanical reset Illuminated. Page -6 and 9-22 and 25 DOUBE AND TRIPE TOUCH