1 Order Codes - Connection Kit RGM2G /... - RGM2S /... - SGM2G /... - RGK2G /... - Connection kit: - - Length service cable Lc in cm Connector model Signal sequence The signal sequence ( signal A before B in clockwise rotation ) is defined from which side the view is directed towards the axis (spindle). "S" - view from above onto the encoder (VS Sensorik standard design) "P" - view from the front onto the spindle (for example, to replace the SIMNS sensor SIZAG & SIMAG) T cable model No indication = no T cable "", "" or "" Attention! Customized design of the connection kit upon request Other types upon request Length T cable in cm (e.g. 050 for 50 cm) No indication, then Lt = Lc + 3 cm T cable T cable length, Lt Connector/Socket Service cable length, Lc Service (signal) cable of encoder Datei: VS-Sensorik_DB Connectionkit Version: 3 Blatt: C1 Datum:

2 Order Codes: T Cable Model Outer sheath material Insulation material Outer diameter Cross-sectional area of individual wire Number of individual wires Colour assignment Sheath FP (Teflon) FP (Teflon) ca. 3,8mm 0,14mm² 8,,,,,,, none Model Outer sheath material Insulation material Outer diameter Cross-sectional area of individual wire Number of individual wires Colour assignment Sheath PUR Polyolefin ca. 4,8mm 0,14mm² 4,, yes Model Outer sheath material Insulation material of individual wires Outer diameter Cross-sectional area of indiviual wire Number of individual wires Colour assignment Sheath FP (Teflon) FP (Teflon) ca. 3,2mm 0,24mm² 2, yes Datei: VS-Sensorik_DB Connectionkit Version: 3 Blatt: 2 Datum:

3 Order Code: Connector Model SGP & SGS SG T-cable ncoder cable Straight Siemens mounting box with cable grip, degree of protection IP7, vibration protection, MC-shielded, flange 25x25 mm Number of pins (AGA000NN ) Prefabricated insulator Connector body 4 Torx-screws M2,5 x Pinassignment SGP Pin assignment SGS Sensor cable type T ("") P ("") Sensor cable type T ("") P ("") 1 Pin 3 Pin Pin assignment SGP & SGS: T-cable Sheath ncoder cable lies on the body of sensor & mounting box Schirm T cable lies on the connector body Pin 4 Datei: VS-Sensorik_DB Connectionkit Version: 3 Blatt: 3 Datum:

4 Order Code: Connector Model SWP & SWS SW T-cable ncoder cable Angled Siemens mounting box with cable grip, degree of protection IP7, vibration protection, MC-shielded, flange 25x25 mm (AWC000NN ) Prefabricated insulator Connector body 4 Torx-screws M2,5 x Pin assignment SWP Pin assignment SWS T ("") P ("") T ("") P ("") 1 Pin 3 Pin Pin assignment SWP & SWS: T cable Sheath ncoder cable lies on the sensor & mounting box Sheath T cable lies on the connector body Pin 4 Datei: VS-Sensorik_DB Connectionkit Version: 3 Blatt: 4 Datum:

5 Order Code: Connector Model FGP & FGS FG Cable end sleeve M3 Cable sheath (Sheating: silicone; 0,5mm²) Straight Intercontec mounting box series 23, vibration protection, flange 25x25 mm, axial O-ring seal (AG A 139 NN ) ncoder cable T cable Heat-shrinkable sleeve Prefabricated insulator Connector body 4 Torx-screws M2,5 x Pin assignment FGP Pin assignment FGS T ("") P ("") T ("") P ("") 1 Pin 3 Pin Pin assignment FGP & FGS: T cable Sheath ncoder cable lies on the sensor & mounting box Sheath T cable lies on the connector body Pin 4 Datei: VS-Sensorik_DB Connectionkit Version: 3 Blatt: 5 Datum:

6 Order Code: Connector Model KXGP & KXGS KXG Counter nut M25x1,5 Straight Intercontec coupling series 23, vibration protection, central attachment, fixed stop rear, wall thicknesses up to 9 mm (AKU A 034 MR ) T-Kabel ncoder kable Fully fabricated coupling Pin assignment KXGP Pin assignment KXGS T ("") P ("") T ("") P ("") 1 Pin 3 Pin Pin assignment KXGP & KXGS: T cable Sheath ncoder cable lies on the sensor & mounting box Sheath T cable lies on the connector body Pin 4 t Datei: VS-Sensorik_DB Connectionkit Version: 3 Blatt: Datum:

7 Order Code: Connector Model SCGS SCGS 52 ø15 Mx1 SCHA shielded connector Mx1 ncoder cable with connector grommet, sheathed IP7 in plugged-in state Fa. SCHA (comparable to model AL-WASS ) Connector injected Stift, CuZn, gilded A ncoder cable Mx1 Fully fabricated connector No T cable possible Pin assignment SCGS P ("") Pin Pin 7, 1 & Pin Sheath ncoder cable lies on the body of sensor & mounting box (connecting thread Mx1) Datei: VS-Sensorik_DB Connectionkit Version: 3 Blatt: 7 Datum:

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

Magnetic gear wheel encoder SGM2G-A with anlog output signals

Magnetic gear wheel encoder SGM2G-A with anlog output signals Magnetic gear wheel encoder SGM2G-A with anlog output signals Contactless incremental encoder for measuring rotary motion Compatible with the measuring system for main spindle drives SIMAG H2 from SIEMENS

More information

Industrial circular connectors

Industrial circular connectors Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

3-Component Measuring System

3-Component Measuring System Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters

More information

Assembly Instruction CAI- Connector with universal Endbell

Assembly Instruction CAI- Connector with universal Endbell CANNON STANDARD Seite 1 von 17 CAI- Connector with universal Endbell Shell size 10 to 36 with APK contact / Trident T2P - contact Illustration and assembly exemplary of CAI Layout 20-0306 with APK / Trident

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Now Available in Black Zinc Nickel

Now Available in Black Zinc Nickel 847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

RJF TV Ethernet connection system for harsh environment

RJF TV Ethernet connection system for harsh environment RJF TV Ethernet connection system for harsh environment ROHS compliant N & BZ RJFTV allows you to use an Ethernet Class D / Cat. 5e connection for 10 BaseT, 100 BaseTx or 1000 BaseT networks in harsh environments.

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

EPIC CIRCON M23 Series Circular Signal Connectors

EPIC CIRCON M23 Series Circular Signal Connectors Circular Signal Connectors CIRCON M2 circular signal connectors are designed to DIN specification N698 and have a standard M2 threaded connection housing. They are offered in coupler, connector, and panel

More information

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning

More information

HARAX circular connector

HARAX circular connector Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor

More information

Absolute encoders multiturn

Absolute encoders multiturn bsolute encoders multiturn Sendix / (shaft / hollow shaft) thernet / IP The Sendix multiturn with patented Intelligent Scan Technology is a particularly high resolution optical encoder without gears and

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

Product Information. HMC 6 Hybrid Motor Cable

Product Information. HMC 6 Hybrid Motor Cable Product Information HMC 6 Hybrid Motor Cable November 2014 HMC 6 Single-cable solution for servo drives Motors normally need two separate cables: One cable for the motor encoder One cable for the motor

More information

Reaction Torque Sensor

Reaction Torque Sensor Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.

More information

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529) Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95 Actuators Technical data sheet 227S-230-05-S1 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

Accessories for Enabling Switches

Accessories for Enabling Switches BD Male plug SS Female connector C- Male flange connector SD Female connector BS Extension cable BD -pin + PE Dimension drawings Male plug SS -pin + PE Female connector C- -pin + PE BD for male plug SS

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Stainless Steel Dissolved Oxygen Electrodes

Stainless Steel Dissolved Oxygen Electrodes Stainless Steel Dissolved Oxygen Electrodes DISSOLVED OXYGEN ELECTRODES The steam sterilizable family of dissolved oxygen electrodes from the phoenix Electrode Company is specifically designed for fermentation

More information

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B, Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified

More information

M23 Connectors and cables

M23 Connectors and cables Contents M23 Connectors and cables M23 Connectors and cables Product Description: SAI M23 Connectors.2 Contact assignment.7 Technical data.8 Overview.10 M23 connector for signal transmission.12 M23 connector

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Waterproof Connectors for Outdoor Use

Waterproof Connectors for Outdoor Use Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight

More information

Differential-Hall-Effect based Sensors Series A5S

Differential-Hall-Effect based Sensors Series A5S Speed and Frequency Seite 1 von 6 Differential-Hall-Effect based Sensors Series A5S Outstanding Characteristics Speed range covering most demands: from close to zero up to 25,000 pulses/second (response

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

UTS discrete wire sealing

UTS discrete wire sealing Technical characteristics Mechanical Durability: 250 matings & unmatings Vibration resistance: Sinusoidal vibrations per CEI 605-4 - from 10 to 2000 Hz Thermal shock: 5 cycles 30 min. from -40 C to 105

More information

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities DEHN + SÖHNE DEHNconductor System No Problems with Proximities DEHNconductor System - New Possibilities for controling Proximities. For preventing dangerous flashovers among parts of external lightning

More information

BNC, N, TNC Connectors

BNC, N, TNC Connectors BNC, N, TNC Connectors ONLINE CATALOG AEP BNC, N, and TNC series connectors are specifically designed for use with miniature flexible and semi-rigid cable. They are available with goldplated or nickel-plated

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

GRS tacho. 1.GRS tachograph service parts

GRS tacho. 1.GRS tachograph service parts 1311 1311 exchange, rebuild and used on request 1314 1314 exchange, rebuild and used on request 1318 1318 exchange, rebuild, used on request 1319 1319 exchange, rebuild and used on request 1324 1324 exchange,

More information

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]

More information

The Wild Children of D38999

The Wild Children of D38999 micro38999 Series High Vibration Miniature Connectors The Wild Children of D38999 A complete range of space saving compact connectors with all of the features and capabilities of D38999 for harsh applications.

More information

Cables. Accessories. For Force, Torque and Strain Sensors

Cables. Accessories. For Force, Torque and Strain Sensors Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater

More information

GISMA UNDERWATER CONNECTORS SERIES 40

GISMA UNDERWATER CONNECTORS SERIES 40 CONTENTS SEITE / PAGE GENERAL 4 GENERAL ARRANGEMENT 5 DESIGN MECHANICAL FEATURES 7 FIBRE OPTIC FEATURS 7 ELECTRICAL FEATURES 7 REFERENCE SYSTEM 8 REFERENCE SYSTEM CONTACTS 9 CONTACT LAYOUTS 9 SUGGESTIONS

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Field bus connections Link structure CMS link structure CMS, B-design. Brochure

Field bus connections Link structure CMS link structure CMS, B-design. Brochure link structure CMS, B-design Brochure 2 link structure CMS, B-design Bus coupler with driver Optional field bus connection with I/O function (CMS), B-design Bus coupler with driver Field bus protocol:

More information

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107 Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety 1.1 Appropriate use...

More information

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions Input Shafts Option G1, ISO 3019-1, outer dia 32 mm-4 (SAE C, 14 teeth) 31.5 ±1 [1.240 ±0.039] MOUNTING FLANGE SURFACE FLANGE 127-4 PER ISO 3019-1 SPLINE DATA NUMBER OF TEETH : 14 PITCH FRACTION : 12/24

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock

More information

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure Electrical connection technologies Electrical connectors Electrical connectors with cable, series CN Brochure Electrical connection technologies Electrical connectors Electrical connectors with cable,

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics SERIES HPQN CONNECTORS DESCRIPTION CONTENT Designed by James Qu at Anoison in 2006, the HPQN is a quick locking version of the widely used type N connector. By replacing the threaded interface of the original

More information

SOURIAU s discrete wire sealing

SOURIAU s discrete wire sealing SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing

More information

The STRIKE Connector System

The STRIKE Connector System I N D U S T R I A L The STRIKE Connector System The STRIKE Connector System The STRIKE Connector System is designed for heavy duty equipment. It combines technical know how of DEUTSCH in connectors with

More information

Magnetic proximity switches

Magnetic proximity switches Magnetic proximity switches Magnetic proximity switches Overview Page 38 Functional principle and installation Page 39 Cylindrical designs Page 41 Rectangular designs Page 42 37 Kurzübersicht Magnetoresistive

More information

Piston rod cylinder Tie rod cylinder Series 167. Brochure

Piston rod cylinder Tie rod cylinder Series 167. Brochure Brochure 2 Tie rod cylinder ISO 6431, Ports: G 1/8 - G 1/2 double-acting with magnetic piston cushioning: pneumatically, adjustable Piston rod: external thread 5 Tie rod cylinder ISO 6431, -53 double-acting

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27. ASSEMBLY 1 - EPS V2 POWER UNIT (SOLUTION 5) 1.1 - POSITIONING INSIDE THE SEAT TUBE WITH ELASTIC SUPPORT IN THE SEAT BRACKET TUBE Depending on which elastic support you have you can secure the V2 power

More information

ODU MINI-SNAP. Miniature Cylindrical Connectors with Push-Pull-Locking Series F

ODU MINI-SNAP. Miniature Cylindrical Connectors with Push-Pull-Locking Series F Catalogue Nr.: 5--a-e ODU MINI-SNAP Miniature Cylindrical Connectors with Push-Pull-Locking Series F ODU Steckverbindungssysteme GmbH & Co. KG, Pregelstraße, D-85 Mühldorf/Inn Telefon: +9/86 /6 56-, Telefax:

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises

More information

RM/55401/M, Roundline cylinder Magnetic piston, double acting

RM/55401/M, Roundline cylinder Magnetic piston, double acting RM/550/M, Roundline cylinder > > Ø... 00 mm > > Clean line design > > ow friction, long life seals > > Standard magnetic piston for full control system versatility Technical features Medium: Compressed

More information

Front axle components, overview

Front axle components, overview just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,

More information

Glenair Military and Industrial Power and Signal Connectors

Glenair Military and Industrial Power and Signal Connectors Glenair Military and Industrial Power and Signal Connectors Series ITS (And FRITS) 5015 Type Reverse Bayonet Connectors Derived from MIL-DTL-5015 and VG95234 Mating mechanism (3 reverse bayonets at 120

More information

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 Fiber Optic VAR Program Hirose Launches Fiber Optic Cabling VAR Program to provide a complete fiber optic cable assembly and wire harness solutions to

More information

K-Type Thermocouple Sensor User s Guide

K-Type Thermocouple Sensor User s Guide K-Type Thermocouple Sensor User s Guide 1 TABLE OF CONTENTS: 1 INTRODUCTION... 2 2 TYPICAL APPLICATION:... 2 3 INSTALLATION RULES:... 2 3.1 Connecting the sensor to M1/MD4 data logger:... 2 3.2 Connecting

More information

ELECTRICAL PLUG TYPE CONNECTIONS

ELECTRICAL PLUG TYPE CONNECTIONS ELECTRICAL PLUG TYPE CONNECTIONS THE COMPLETE RANGE FOR COMMERCIAL VEHICLES, PASSENGER CARS AND SPECIAL VEHICLES DETAILED PRODUCT OVERVIEWS WITH ACCESSORIES AND WIRING DIAGRAMS ESPECIALLY STURDY PLUG SYSTEMS

More information

Encoder WDG 58B. www.wachendorff-automation.com/wdg58b

Encoder WDG 58B. www.wachendorff-automation.com/wdg58b Encoder WDG www.wachendorffautomation.com/wdgb Wachendorff utomation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and customer versions Maximum

More information

PVM Piston Pumps Service Manual

PVM Piston Pumps Service Manual PVM Piston Pumps Service Manual PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141 Table of Contents Service Parts Pump Description... 3 Basic pump Pump Operation Controls Types Part Identification...

More information

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

W 2: Subminiature photoelectric switch series: extremely small and extremely strong Photoelectric proximity switches BGS Photoelectric proximity switches energetic, (V optics) Photoelectric reflex switches Through-beam photoelectric switches W : Subminiature photoelectric switch series:

More information

Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections

Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections Quick Connect RTDs, Cordsets and Transmitter with M12 Connections 1 Temperature Measurement Experts Since 1960, urns Engineering has been an industry leader in the design and manufacture of temperature

More information

LVDT. Inductive Position Transducer. SM Series. Key-Features:

LVDT. Inductive Position Transducer. SM Series. Key-Features: LVDT Inductive Position Transducer SM Series Key-Features: Content: - Measurement ranges 2...200 mm - External, or cable electronics with cable break detection - Linearity up to ±0.10 % of full scale -

More information

ALBINS SEQUENTIAL SHIFTER

ALBINS SEQUENTIAL SHIFTER ALBINS SEQUENTIAL SHIFTER Updated 12/11/11 8-AGB5-INST GENERAL NOTES The Albins Sequential Shifter is specifically designed for AGB transaxles. It features an integral reverse lockout lever and has a position

More information

125 DUKE EU 2011 SPARE PARTS MANUAL: CHASSIS ENGLISH ART.NO.: 3CF8003K4EN

125 DUKE EU 2011 SPARE PARTS MANUAL: CHASSIS ENGLISH ART.NO.: 3CF8003K4EN SPARE PARTS MANUAL: CHASSIS ART.NO.: 3CF8003K4EN ENGLISH INDEX FRONT FORK, TRIPLE CLAMP HANDLEBAR, CONTROLS FRAME SIDE / CENTER STAND 3x 4x 5x 6x SHOCK ABSORBER SWING ARM EXHAUST SYSTEM AIR FILTER 7x

More information

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal

More information

IMVIB. Online vibration monitoring for Ariel compressors

IMVIB. Online vibration monitoring for Ariel compressors IMVIB Online vibration monitoring for Ariel compressors The cost-effective way to add spectral vibration measurement & trending on critical machinery Monitoring vibration trends of your industrial equipment

More information

3-PHASE STEPPING MOTOR. VRDM 39x. Document: 100000116 Edition: d013, 2005.02

3-PHASE STEPPING MOTOR. VRDM 39x. Document: 100000116 Edition: d013, 2005.02 -PHASE STEPPING MOTOR VRDM 9x Edition: d, 5. Features common to all motor types Test voltage to DIN EN 64 part Insulation class F Run-out and perpendicularity to DIN 4955 N Paint: black RAL 95 Security

More information

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-... Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information

More information

FG MOISTURE MONITOR Installation & Operation Manual

FG MOISTURE MONITOR Installation & Operation Manual FG MOISTURE MONITOR Installation & Operation Manual Issue 3.0 7/20/10 1 Contents SERVICE AND TECHNICAL SUPPORT... 2 INSTALLATION:... 3 MOISTURE SENSOR INSTALLATION:... 3 SENSOR CONNECTOR:... 5 MONITOR

More information

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.

More information

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5 www.thomsonlinear.com Version History Edition Number Edition Date Reason for Revision 1 2004 First edition

More information

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

Rear wheel brakes, servicing. Стр. 1 из 45. Note: Volkswagen Touareg - Rear wheel brakes, servicing Стр. 1 из 45 46-2 Rear wheel brakes, servicing Rear brakes, FN 44 brake caliper, servicing Note: After replacing brake pads, depress brake pedal firmly

More information

HIPERDRIVE HRA71 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment

HIPERDRIVE HRA71 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment HIPERDRIVE HRA7 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment Convincing benefits: Highly integrated system Low cabling requirements: VDC

More information

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12 DUAL BEVEL COMPOUND MITER SAW B27A PAGE 1 OF 6 BASE ASSEMBLY 00 0 EXAMPLE: Component Parts (Small #) Are Included When Ordering The Assembly (Large #). SPECIFY CATALOG NO. AND NO. WHEN ORDERING PARTS 1 02-80-0050 Thrust Bearing (1) 2 05-80-0510

More information

Original BMW Accessory. Installation Instructions.

Original BMW Accessory. Installation Instructions. Original BMW Accessory. Installation Instructions. USB/Audio Interface SA 6FL Retrofit BMW Series (E 8, E 8, E 87, E 88) BMW 3 Series (E 90, E 9, E 9, E 93) These installation instructions are only valid

More information

Connection cable for amplifier Type 4701AxA and torque sensor Type 4501A... (0143SD) version Q/R/H

Connection cable for amplifier Type 4701AxA and torque sensor Type 4501A... (0143SD) version Q/R/H for Torque s 4501A... to 4504A... KSM... KSM007186 KSM071860 Connection cable for amplifier 4701AxB and torque sensor 4501A... (0143SD) version Q/R/H Contacts 6 Length (m) L = 5 m; customised length, KSM071860

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

W1 Connector W1 Adapter W1 Termination

W1 Connector W1 Adapter W1 Termination Data Sheet W1 Connector W1 Adapter W1 Termination DC to 110 GHz A complete coaxial connector system with mode-free performance to 110 GHz Features Excellent RF Performance to 110 GHz 50Ω Impedance Low

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

Robot Welding Torch System

Robot Welding Torch System T e C H N O L O G y f O R T H e W e L d e R s W O R L d. Robot Welding Torch System W W Robot welding torch system... The universal MIG/MAG-torch system for robot welding: A new interface and cable assembly

More information

Installation instruction CASAFLEX - Connecting piece DN 100

Installation instruction CASAFLEX - Connecting piece DN 100 1 CASAFLEX - 11 10 114,3 x 4,5 3 5 2 4 1 7 6 8 12 9 Do not begin work until you have read the installation instruction carefully. 1 internal backing sleeve 2 graphite packing 3 connecting piece 4 thrust

More information