Confocal Microscopy. Chapter 2
|
|
|
- Chad Smith
- 9 years ago
- Views:
Transcription
1 Chapter 2 Confocal Microscopy This Chapter offers a brief introduction to confocal microscopy and to other experimental techniques employed in this thesis.
2 Unraveling structure and dynamics by confocal microscopy 2.1 Fundamentals of Light Microscopy I have already said that there are mirrors which increase every object they reflect. I will add that everything is much larger when you look at it through water. Letters, however thin and obscure, are seen larger and clearer through a glass ball filled with water. Fruits seem more beautiful than they actually are if they are floating in a glass bowl. With these words the 1st-century A.D. philosopher Seneca described the astonishment at optical magnification as a tool to better see very small things not visible to the unaided eye. [1,2] The step from the use of a single lens as magnifier to the assembly of several lenses together into the first microscope took many centuries. The paternity of the first compound microscope, basically the combination of two lenses, is still controversial, although credit is commonly shared by the Dutchman Zacharias Janssen (or his father Hans) in 1590 and the Italian Galileo Galilei in [2] This discovery represented a breakthrough for natural sciences, opening the path to the development of microbiology and tissue biology. From the discovery of the first microscope, scientists have improved and adapted the technique to specific uses and purposes, making the microscope a ubiquitous tool in a broad range of the experimental sciences The compound light microscope Two main parts characterize a compound light microscope: the objective lens and the eyepiece, also called the ocular. The combination of these two lenses produces the final magnification of the object under examination according to the following equation: M final = M obj x M oc. (1) where M obj is the magnification obtained with the first lens and M oc is the magnification performed by the second lens. [3] Figure 2.1 shows the concept of optical magnification and how the final image reaches the human eye. 18
3 Chapter 2 Figure 2.1: Geometric optics of a compound microscope. The objective produces a first magnified image of the specimen, the real intermediate image at the ocular. The ocular generates a real image of the object on the eye retina, which perceives the object as a virtual image placed 25 cm far from the eye. The objective produces the so-called intermediate image, the initial magnified image of the object placed outside the focal distance F of the objective. The intermediate image plane is placed at a fixed position with respect to the front focal plane of the ocular (inside the ocular focal distance), producing a real image on the retina, which is interpreted by the eye as a virtual magnified image at ~ 25 cm from the eye frontal aperture (the eye pupil). [3] 19
4 Unraveling structure and dynamics by confocal microscopy For many centuries the standard length of a microscope tube was 160- or 170- mm. These instruments, as shown in Figure 2.1, use convergent light in the interlens space. Metallurgists and geologists require polarized light, and thus, before the invention of thin polarizers, massive prisms and other accessories were inserted in the inter-lens space. In the 1930s, confronted with insufficient space in the standard tube and plagued with aberration correction problems, a manufacturer first attempted infinite tube length optics. However, this type of microscope became common only in the 1980s as infinite tube-length microscopes (see Figure 2.2). Parallel Light Beam Infinity Space Objective Specimen Tube Lens F Eyepiece Eyepiece Eye Lens Real Image on Retina F Objective Magnified Virtual Image (Perceived) Intermediate Real Image 25 cm Figure 2.2: Scheme of infinite tube-length microscope optics. In this configuration the specimen lies exactly at the focal distance of the objective. In this configuration the specimen is placed exactly at the frontal focal plane of the objective, creating a region in which the light beams between objective and eyepiece are parallel. This provides the necessary space to insert additional optical elements without introducing aberrations and while retaining the parfocality of sets of objectives (Figure 2.2). [3,4] Conjugate field and aperture planes in a focused microscope If the microscope is properly aligned and focused, two distinct sets of conjugated focal planes can be identified, placed along the optical path of the microscope. [3,5] 20
5 Chapter 2 Under Kohler illumination, the planes, four for each set, occupy fixed relative positions. The illumination conjugate set correlates the apertures point source, starting from the lamp filament, through the front aperture of the condenser, to the objective rear focal plan and the microscope s exit pupil. The conjugate field or conjugate image planes are the field diaphragm, the specimen or object plane, the intermediate image plane, and the retina or the image plane of an electronic sensor. [6] Figure 2.3 shows the conjugate focal planes in the Koehler illumination setting. Conjugate Field Planes Conjugate Apertures Planes Retina Eye Eye Pupil Intermediate Image Specimen Plane Field Stop Diaphragm Eyepiece Objective Slide Condenser Condenser Lens Lamp Rear Focal Plane of Objective Front Focal Plane of Condenser Lamp Filament Figure 2.3: Correlation between the conjugated plane sets in Koehler illumination. The properties of the conjugate planes in a microscopy setup are several; among the other, the four planes of a set are focused simultaneously, and when the light rays are focused into the apertures in the illumination path, they are basically parallel when crossing the image planes in the field path, thus revealing their reciprocal nature. [5] Diffraction and optical resolution in image formation A fundamentally important physical phenomenon for imaging is light diffraction. The specimen illuminated under a microscope works as a complex 21
6 Unraveling structure and dynamics by confocal microscopy diffraction grating. The diffracted light is focused on the rear focal plane of the objective, and the resultant pattern can be viewed as the reciprocal image of the specimen. [3,6] Therefore, the diffraction pattern of a point object when highly magnified results in a central spot (diffraction disk) surrounded by a series of diffraction rings. The bright central region is referred to as the zeroth-order diffraction spot, while the rings are called, in order from smaller to larger, the first, second, third, etc. order diffraction rings. When the microscope is properly focused, the intensity of light between the rings is zero. This point source diffraction pattern is referred to as Airy disk (after Sir George B. Airy). The size of the central spot in the Airy pattern is related to the wavelength of light and the numerical aperture (NA) of the objective. In terms of resolution, the radius of the diffraction Airy disk in the lateral (x,y) image plane is defined by the following formula [6 8] : A Airy = λ / (2 NA) (2) where λ is the average wavelength of illumination (in transmitted light), and NA = n sin(θ) where n is the refractive index of the imaging medium (usually air, water, glycerin, or oil) multiplied by the sine of the aperture angle (sin(θ)). The diffraction-limited resolution theory was developed by Ernst Abbe in 1873 (Eq. (2)) and later refined by Lord Rayleigh in Eq. (3) quantitatively measures the separation necessary between two Airy patterns in order to distinguish them as separate entities. R Airy = 0.61 / NA (3) From the equation above it is clear that a higher resolution can be obtained using a high numerical aperture (NA) objective, which e.g., can be achieved using fluid immersion objectives. [3,6] Much research has been devoted to developing tools that are able to image objects with a resolution lower than the Rayleigh limit. One of these strategies led to the development of confocal microscopy, with which a resolution can be obtained that is about 30% higher than the Rayleigh limit. [9] 22
7 Chapter 2 View in the section of rear focal plane of Objective Rear focal plane of Objective Objective Object (a) (b) (c) (d) Figure 2.4: The image is formed due to the interference of rays which are deviated by the object (grating) and rays, which are not deviated, and are collected and interfere in the image plane. In the rear focal plane of the objective a diffraction pattern is produced, which is the inverse transform of the image in the image plane. Abbey's theory explains that if the specimen does not produce diffraction (a), or the objective does not collect the diffraction orders (b), the image cannot be formed. When at least two adjacent diffraction orders (c) are collected, the image is formed. A higher degree of definition of the image is correlated to a larger number of diffraction orders collected by the objective (d). 2.2 Confocal Laser Scanning Microscopy Fluorescence Microscopy has been one of the most exploited microscopy techniques since its development in the 1940s. Fluorescence Microscopy is based on the idea that the optical excitation of the sample creates electronic excited states, which then emit light upon relaxation to the ground state. Fluorescence Microscopy is currently one of the most popular techniques for detecting biological processes. [10] The fluorescence of a sample can be exploited to identify its different components by their intrinsic emission or by using chromophores to functionalize specific components. [3] 23
8 Unraveling structure and dynamics by confocal microscopy The concept of Confocal Laser Scanning Microscopy (CLSM) is a further development of Fluorescence Microscopy, which arose from an idea from Marvin Minsky in the 1950s. [11,12] Compared to a conventional wide-field optical microscope, the CLSM has several advantages. Amongst other things, these include an improved resolution in the xy plane due to the reduction of the background light from out-of-focus planes, and a better control of depth of field and therefore the possibility for 3D imaging of the sample by collecting images from a different focus (optical sections) of thick specimens. [3] In the following, the basic concepts behind the functioning of a confocal microscope are discussed The optical principle of confocal imaging The working principle of the confocal microscope is based on the introduction of a confocal aperture, generally an adjustable pinhole, in the conjugated image plan of a fluorescence microscope. [12] Figure 2.5 shows the scheme of the optical path in a modern confocal microscope in inverted configuration. The excitation light (a scanning laser beam) is directed from the Light Source Pinhole Aperture to a dichroic mirror and focused through the objective system to a diffraction-limited spot within the specimen. The fluorescence emitted by the specimen after excitation is then collected by the same objective system and transmitted through the dichroic mirror to the photomultiplier detector. The Confocal Pinhole placed at the entrance of the detector allows only the fluorescence coming from the specimen in the focal plane of the system to reach the detector. The signal originated in the planes of the specimen that are out-of-focus (green and blue rays paths in Fig. 2.5) is rejected by the confocal pinhole, thus improving the signal-to-noise ratio. Adjusting the pinhole to smaller aperture dimensions, a higher rejection of the out-of-focus information, together with the suppression of a significant amount of stray light can be obtained, resulting in a higher contrast of the image. [3] 24
9 Chapter 2 Photomultiplier Detector Confocal Pinhole Laser Excitation Source Dichoic Mirror Light Source Pinhole Aperture Objective Lens Focal Plane Specimen Figure 2.5: The principle of Confocal Laser Microscope. The pinhole aperture placed in the confocal image plan rejects the out-of-focus emission light (green and blue rays). Only the in focus light (red optical path) reaches the photomultiplier tube, contributing to the image formation Confocal Laser Scanning Microscope In a Confocal laser microscope only a small single volume of the specimen is excited; upon collection of the signal, the image is formed by a point-by-point digital reconstruction of the single volumes. In order to generate images of more extended portions of the object, the sample can be moved in front of the exciting beam or, alternatively, the laser beam can be raster scanned across the sample. [13] The advantage in the latter case is that the reconstruction of the sample image requires only a few milliseconds, whereas in the first case it can require several minutes. However, the laser scanning approach requires optics of high quality that are aberration corrected also outside their optical axis; in the case of the sample scanning, the optics will always work in their optical axis. Figure 2.6 shows the schematic of a laser scanning head. 25
10 Unraveling structure and dynamics by confocal microscopy Figure 2.6: The scanning head of a confocal microscope. The laser path (blue line) and the luminescence path (green line) are pictured. The mirrors move because of galvanometric motors, which allow to raster scan the laser beam on the surface of the specimen. The raster pattern creation is commonly based on the use of a pair of galvanometric mirrors, which move the light beam in mutually perpendicular directions within the main axis of the scanning head. [13] Fluorescent light coming from the specimen follows the reverse optical path with respect to the laser beam, resulting in a de-scanned emission. The descanning process is fast enough so that the resulting image, digitally processed with the intensity detected point-by-point by the photomultiplier tube, is steady Spatial resolution As mentioned above, a point light source produces a diffraction pattern in the image plane, with a bright central area known as Airy disk, and the possibility of discerning two of these areas was used by Rayleigh to measure the resolution of the optical system (see Eq. (3)). [6,11] By adjusting the pinhole aperture in order to achieve a size aperture comparable to the diameter of 0.25 Airy units (AU), where 1 AU =1.22( exc /NA), it is possible to reduce by ~1000-fold the flare originated by out-of-focus emission, with respect the wide-field microscopy. [11] This gives rise to a theoretical xy resolution in accordance with the following equation: R xy ~ 0.6 / ( 2 NA) = 0.4 / NA (4) 26
11 Chapter 2 where is the wavelength of the light emitted and NA is the numerical aperture of the objective. In the case of the z direction, the resolution will be approximated by the following equation: Rz ~ 1.4 n / NA2 (5) where n is the refractive index, and the other quantities are as above. However, more than the resolution, in the case of the z-direction the real advantage is determined by the optical sectioning capability. It is also worth noting that a variation of the pinhole aperture will result in different imaging resolutions Optical sectioning As mentioned above, one of the most important properties of the confocal laser microscope (CLM) is the possibility of performing optical sectioning cutting in optical slices the sample. [13,14] The main advantage with respect to other techniques is that the optical sectioning is neither invasive nor destructive. Optical sectioning can be obtained by using a z-stack of confocal images, which are obtained by varying the focus through the depth of the specimen. These images are then recombined with specific software. In this way, 3D images of the specimen are easily achievable. Figure 2.7: CLM micrographs of patato starch granules in water based solution, generated by zstacking of the raster images using a 3D reconstruction software. Images a) and b) show the same sample portion viewed from different angles. 27
12 Ar+ 488 nm He-Ne 543 nm He-Ne 632 nm Unraveling structure and dynamics by confocal microscopy Figure 2.7 shows two 3D micrographs obtained by optically sectioning a sample of potato starch granules in water solution. The images a) and b) present the same sample volume observed from different angles. Obviously, the optical sectioning can be used when the specimen has z dimensions that are larger than the z-resolution of the instrument. 2.3 Experimental setups The following section describes the specific set-ups used to perform the experimental work presented in this thesis Confocal Laser Scanning Microscopy (CLSM) and spatially resolved photoluminescence spectroscopy setup In Figure 2.8 a scheme of the experimental setup for confocal laser scanning microscopy (CLSM) and spatially resolved photoluminescence (PL) measurements is reported. Computer Confocal Microscope Scanning Head Monochromator Computer OF CCD CCD PMT ~ nm OF ~ nm BBO Pump Laser Ti: Sapphire Laser Figure 2.8: Scheme of the Confocal Laser Scanning Microscopy (CLSM) and spatially resolved photoluminescence spectroscopy setup. 28
13 Chapter 2 The setup is based on the coupling of the second harmonic of a mode-locked Ti: sapphire femtosecond laser (Coherent) into the scanning head of a Nikon Eclipse Ti microscope in backscattering configuration. The optical elements used to perform the coupling between the free-space laser beam and the microscope are depicted in Figure 2.9. A Plan 40 times magnification Olympus objective mounted on a fiber launch system focuses the beam into a single mode optical fiber, which is connected to the scanning head of the microscope. The system is equipped with three axis differential adjusters, which can achieve fine adjustments of 50 µm/rev. Figure 2.9: Laser-Microscope coupling system. An objective focuses the free space laser beam into the single mode optical fiber, which is connected to the microscope scanning head. The Ti: sapphire laser delivers pulses of ~ 150 fs width at a repetition of ~ 76 MHz; the wavelength of the pulses can be tuned in the range ~ nm. By coupling the laser beam into a nonlinear LBO crystal, the second harmonic (~ nm) can be generated. Three single line cw lasers (488nm, 543 nm and 632 nm) are also connected to the scanning head of the microscope by using the same single mode optical fibers (see Fig. 1.8). The Nikon Eclipse Ti inverted microscope mounts a set of several objectives, which have different NA and working distances. 29
14 Unraveling structure and dynamics by confocal microscopy All the micrographs presented in this thesis (unless otherwise specified) were performed with a 60 times magnification immersion oil objective, characterized by a NA = 1.4. The sample imaging was obtained by collecting the photoluminescence signal coming from the specimen with a set of photomultiplier tubes, each centered at a different spectral range and covering together a total detection spectral range between 460 till 750 nm. In order to correlate the morphology features and spectroscopic properties, spatially resolved spectroscopy was performed, collecting the photoluminescence signal of the sample with a monochromator coupled with an Image EM CCD camera from Hamamatsu. To perform the spatially resolved photoluminescence experiments, customized dichroic mirrors were acquired for the microscope scanning head Bright-field Microscopy Bright-field microscopy was performed with a Nikon Eclipse E600 light microscope using a 20x objective lens. The images were collected with a Nikon COOLPIX 4500 camera. 30
15 Chapter 2 References [1] L. A. Seneca, Naturales questiones, Vol. I, AC. [2] T. G. Rochow, E. G. Rochow, An Introduction to Microscopy by Means of Light, Electrons, X-Rays, or Ultrasound.; Plenum Publishing Corporation, [3] D. B. Murphy, M. W. Davidson, Fundamentals of Light Microscopy and Electronic Imaging; Second.; Wiley-Blackwell A John Wiley & sons, Inc., Publication, [4] G. Sluder, J. J. Nordberg, in Methods in Cell Biology; Leslie Wilson and Paul Matsudaira, Ed.; Academic Press, 2003; Vol. 72, pp [5] M. W. Davidson, T. J. Fellers, Nikon MicroscopyU Whitepaper, [6] M. W. Davidson, M. Abramowitz, in Encyclopedia of Imaging Science and Technology; John Wiley & Sons, Inc., [7] S. Inoué, K. R. Spring, Video Microscopy: The Fundamentals; Plenum Press, [8] M. Abramowitz, Contrast Methods in Microscopy: Transmitted Light; Olympus Corporation, Precision Instrument Division, [9] M. Young, Optics and Lasers: Including Fibers and Optical Waveguides; Springer Science & Business Media, [10] D. E. Wolf, In Methods in Cell Biology; Greenfield Sluder and David E. Wolf, Ed.; Digital Microscopy, 3rd Edition; Academic Press, 2007; Vol. 81, pp [11] C. L. Smith, In Current Protocols in Molecular Biology; John Wiley & Sons, Inc., [12] Z. Földes-Papp, U. Demel, G. P. Tilz, Int. Immunopharmacol. 2003, 3, [13] M. A. Loi, E. Da Como, M. Muccini, In Photophysics of Molecular Materials; Lanzani, G., Ed.; Wiley-VCH Verlag GmbH & Co. KGaA, 2005; pp [14] J.-A. Conchello, J. W. Lichtman, Nat. Methods 2005, 2,
16 Unraveling structure and dynamics by confocal microscopy 32
Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012
Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012 You are sitting at your microscope working at high magnification trying to sort out the three-dimensional compartmentalization
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL Robert Bagnell 2006 This tutorial covers the following CLSM topics: 1) What is the optical principal behind CLSM? 2) What is the spatial resolution in X, Y,
Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.
Revision problem Chapter 18 problem 37 page 612 Suppose you point a pinhole camera at a 15m tall tree that is 75m away. 1 Optical Instruments Thin lens equation Refractive power Cameras The human eye Combining
WAVELENGTH OF LIGHT - DIFFRACTION GRATING
PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant
Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University
Chapter 4 Microscopy, Staining, and Classification 2012 Pearson Education Inc. Lecture prepared by Mindy Miller-Kittrell North Carolina State University Microscopy and Staining 2012 Pearson Education Inc.
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Some limitations (disadvantages) of NSOM A trade-off
Measuring the Point Spread Function of a Fluorescence Microscope
Frederick National Laboratory Measuring the Point Spread Function of a Fluorescence Microscope Stephen J Lockett, PhD Principal Scientist, Optical Microscopy and Analysis Laboratory Frederick National
MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.
MICROSCOPY I. OBJECTIVES To demonstrate skill in the proper utilization of a light microscope. To demonstrate skill in the use of ocular and stage micrometers for measurements of cell size. To recognize
THE COMPOUND MICROSCOPE
THE COMPOUND MICROSCOPE In microbiology, the microscope plays an important role in allowing us to see tiny objects that are normally invisible to the naked eye. It is essential for students to learn how
Bio 321 Lightmicroscopy Electronmicrosopy Image Processing
Bio 321 Lightmicroscopy Electronmicrosopy Image Processing Urs Ziegler Center for Microscopy and Image Analysis Light microscopy (Confocal Laser Scanning Microscopy) Light microscopy (Confocal Laser Scanning
Care and Use of the Compound Microscope
Revised Fall 2011 Care and Use of the Compound Microscope Objectives After completing this lab students should be able to 1. properly clean and carry a compound and dissecting microscope. 2. focus a specimen
Zeiss 780 Training Notes
Zeiss 780 Training Notes 780 Start Up Sequence Do you need the argon laser, 458,488,514nm lines? No Turn on the Systems PC Switch Turn on Main Power Switch Yes Turn on the laser main power switch and turn
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
Experiment 5. Lasers and laser mode structure
Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,
2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.
Physics for Scientists and Engineers, 4e (Giancoli) Chapter 33 Lenses and Optical Instruments 33.1 Conceptual Questions 1) State how to draw the three rays for finding the image position due to a thin
Endoscope Optics. Chapter 8. 8.1 Introduction
Chapter 8 Endoscope Optics Endoscopes are used to observe otherwise inaccessible areas within the human body either noninvasively or minimally invasively. Endoscopes have unparalleled ability to visualize
Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments
Lecture 17. Image formation Ray tracing Calculation Lenses Convex Concave Mirrors Convex Concave Optical instruments Image formation Laws of refraction and reflection can be used to explain how lenses
GRID AND PRISM SPECTROMETERS
FYSA230/2 GRID AND PRISM SPECTROMETERS 1. Introduction Electromagnetic radiation (e.g. visible light) experiences reflection, refraction, interference and diffraction phenomena when entering and passing
9/16 Optics 1 /11 GEOMETRIC OPTICS
9/6 Optics / GEOMETRIC OPTICS PURPOSE: To review the basics of geometric optics and to observe the function of some simple and compound optical devices. APPARATUS: Optical bench, lenses, mirror, target
EXPERIMENT #1: MICROSCOPY
EXPERIMENT #1: MICROSCOPY Brightfield Compound Light Microscope The light microscope is an important tool in the study of microorganisms. The compound light microscope uses visible light to directly illuminate
C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same
1. For a plane mirror, compared to the object distance, the image distance is always A) less B) greater C) the same 2. Which graph best represents the relationship between image distance (di) and object
Optical laser beam scanner lens relay system
1. Introduction Optical laser beam scanner lens relay system Laser beam scanning is used most often by far in confocal microscopes. There are many ways by which a laser beam can be scanned across the back
Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications
Screw thread image generated by WLI Steep PSS angles WLI color imaging Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications 3D optical microscopy is a mainstay metrology
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012
Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012 Figure 1.1 illustrates the parts of an upright compound microscope and indicates the terminology that I use in these notes. Figure 1.1. Parts of a Compound
1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002
05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical
Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...
Confocal Microscopy and Atomic Force Microscopy (AFM) of biofilms A very brief primer... Fundamentals of Confocal Microscopy Based on a conventional fluorescence microscope Fluorescent Microscope Confocal
Geometric Optics Converging Lenses and Mirrors Physics Lab IV
Objective Geometric Optics Converging Lenses and Mirrors Physics Lab IV In this set of lab exercises, the basic properties geometric optics concerning converging lenses and mirrors will be explored. The
Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES
BIODIVERSITY I BIOL1051 Microscopy Professor Marc C. Lavoie [email protected] MAJOR FUNCTIONS OF MICROSCOPES MAGNIFY RESOLVE: => INCREASE CONTRAST Microscopy 1. Eyepieces 2. Diopter adjustment
Forensic Science: The Basics. Microscopy
Forensic Science: The Basics Microscopy Chapter 6 Jay A. Siegel,Ph.D. Power point presentation by Greg Galardi, Peru State College, Peru Nebraska Presentation by Greg Galardi, Peru State College CRC Press,
Microscope Lab Introduction to the Microscope Lab Activity
Microscope Lab Introduction to the Microscope Lab Activity Wendy Kim 3B 24 Sep 2010 http://www.mainsgate.com/spacebio/modules/gs_resource/ CellDivisionMetaphase.jpeg 1 Introduction Microscope is a tool
Diffraction of a Circular Aperture
Diffraction of a Circular Aperture Diffraction can be understood by considering the wave nature of light. Huygen's principle, illustrated in the image below, states that each point on a propagating wavefront
waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object
PHYS1000 Optics 1 Optics Light and its interaction with lenses and mirrors. We assume that we can ignore the wave properties of light. waves rays We represent the light as rays, and ignore diffraction.
Physics 441/2: Transmission Electron Microscope
Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This
LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes
LBS-300 Beam Sampler for C-mount Cameras P/N SP90183, SP90184, SP90185 and SP90186 YAG Focal Spot Analysis Adapter P/N SP90187, SP90188, SP90189, SP90190, SP90191 User Notes Ophir-Spiricon Inc. 60 West
First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between
Optical Differences Between Telescopes and Microscopes Robert R. Pavlis, Girard, Kansas USA icroscopes and telescopes are optical instruments that are designed to permit observation of objects and details
Basic Optics System OS-8515C
40 50 30 60 20 70 10 80 0 90 80 10 20 70 T 30 60 40 50 50 40 60 30 C 70 20 80 10 90 90 0 80 10 70 20 60 50 40 30 Instruction Manual with Experiment Guide and Teachers Notes 012-09900B Basic Optics System
PHYS 39a Lab 3: Microscope Optics
PHYS 39a Lab 3: Microscope Optics Trevor Kafka December 15, 2014 Abstract In this lab task, we sought to use critical illumination and Köhler illumination techniques to view the image of a 1000 lines-per-inch
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND
DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND THE THREE-DIMENSIONAL DISTRIBUTION OF THE RADIANT FLUX DENSITY AT THE FOCUS OF A CONVERGENCE BEAM
Introduction to microstructure
Introduction to microstructure 1.1 What is microstructure? When describing the structure of a material, we make a clear distinction between its crystal structure and its microstructure. The term crystal
Lenses and Apertures of A TEM
Instructor: Dr. C.Wang EMA 6518 Course Presentation Lenses and Apertures of A TEM Group Member: Anup Kr. Keshri Srikanth Korla Sushma Amruthaluri Venkata Pasumarthi Xudong Chen Outline Electron Optics
MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY
MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY Adapted from Foundations of Biology I; Lab 6 Introduction to Microscopy Dr. John Robertson, Westminster College Biology Department,
Applications of confocal fluorescence microscopy in biological sciences
Applications of confocal fluorescence microscopy in biological sciences B R Boruah Department of Physics IIT Guwahati Email: [email protected] Page 1 Contents Introduction Optical resolution Optical
Rutgers Analytical Physics 750:228, Spring 2016 ( RUPHY228S16 )
1 of 13 2/17/2016 5:28 PM Signed in as Weida Wu, Instructor Help Sign Out Rutgers Analytical Physics 750:228, Spring 2016 ( RUPHY228S16 ) My Courses Course Settings University Physics with Modern Physics,
Chapter 17: Light and Image Formation
Chapter 17: Light and Image Formation 1. When light enters a medium with a higher index of refraction it is A. absorbed. B. bent away from the normal. C. bent towards from the normal. D. continues in the
Near-field scanning optical microscopy (SNOM)
Adviser: dr. Maja Remškar Institut Jožef Stefan January 2010 1 2 3 4 5 6 Fluorescence Raman and surface enhanced Raman 7 Conventional optical microscopy-limited resolution Two broad classes of techniques
EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS
EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS The following website should be accessed before coming to class. Text reference: pp189-196 Optics Bench a) For convenience of discussion we assume that the light
Solution Derivations for Capa #14
Solution Derivations for Capa #4 ) An image of the moon is focused onto a screen using a converging lens of focal length (f = 34.8 cm). The diameter of the moon is 3.48 0 6 m, and its mean distance from
It has long been a goal to achieve higher spatial resolution in optical imaging and
Nano-optical Imaging using Scattering Scanning Near-field Optical Microscopy Fehmi Yasin, Advisor: Dr. Markus Raschke, Post-doc: Dr. Gregory Andreev, Graduate Student: Benjamin Pollard Department of Physics,
Lecture Notes for Chapter 34: Images
Lecture Notes for hapter 4: Images Disclaimer: These notes are not meant to replace the textbook. Please report any inaccuracies to the professor.. Spherical Reflecting Surfaces Bad News: This subject
Biomedical & X-ray Physics Kjell Carlsson. Light Microscopy. Compendium compiled for course SK2500, Physics of Biomedical Microscopy.
Biomedical & X-ray Physics Kjell Carlsson Light Microscopy Compendium compiled for course SK2500, Physics of Biomedical Microscopy by Kjell Carlsson Applied Physics Dept., KTH, Stockholm, 2007 No part
Light and its effects
Light and its effects Light and the speed of light Shadows Shadow films Pinhole camera (1) Pinhole camera (2) Reflection of light Image in a plane mirror An image in a plane mirror is: (i) the same size
Interference. Physics 102 Workshop #3. General Instructions
Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by
Rodenstock Photo Optics
Rogonar Rogonar-S Rodagon Apo-Rodagon N Rodagon-WA Apo-Rodagon-D Accessories: Modular-Focus Lenses for Enlarging, CCD Photos and Video To reproduce analog photographs as pictures on paper requires two
Principles of Microscopy and Confocal and Fluorescence Microscopy
Principles of Microscopy and Confocal and Fluorescence Microscopy Content This course in Light Microscopy follows the series of successful courses in Light Microscopy, Confocal and Fluorescence Microscopy
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications Saulius Marcinkevičius Optics, ICT, KTH 1 Outline Optical near field. Principle of scanning near field optical microscope
EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab
EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent
Chapter 1 High-Resolution Optical and Confocal Microscopy
Chapter 1 High-Resolution Optical and Confocal Microscopy Olaf Hollricher and Wolfram Ibach Abstract In this chapter, the theory of optical image formation in an optical microscope is described, and the
Imaging techniques with refractive beam shaping optics
Imaging techniques with refractive beam shaping optics Alexander Laskin, Vadim Laskin AdlOptica GmbH, Rudower Chaussee 29, 12489 Berlin, Germany ABSTRACT Applying of the refractive beam shapers in real
Study Guide for Exam on Light
Name: Class: Date: Study Guide for Exam on Light Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Which portion of the electromagnetic spectrum is used
Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, 1849-1853, 1 April 1998)
Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, 1849-1853, 1 April 1998) Geoff Andersen and R. J. Knize Laser and Optics Research Center
Fundamentals of modern UV-visible spectroscopy. Presentation Materials
Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms
Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light
1.1 The Challenge of light 1. Pythagoras' thoughts about light were proven wrong because it was impossible to see A. the light beams B. dark objects C. in the dark D. shiny objects 2. Sir Isaac Newton
Introduction to Optics
Second Edition Introduction to Optics FRANK L. PEDROTTI, S.J. Marquette University Milwaukee, Wisconsin Vatican Radio, Rome LENO S. PEDROTTI Center for Occupational Research and Development Waco, Texas
Acousto-optic modulator
1 of 3 Acousto-optic modulator F An acousto-optic modulator (AOM), also called a Bragg cell, uses the acousto-optic effect to diffract and shift the frequency of light using sound waves (usually at radio-frequency).
A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine
Chapter 1 A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine This chapter provides a historical foundation of the field of microscopy and outlines the significant
Magnification Devices
LOW VISION AIDS Optical Characteristics of the Low Vision Patient The definition of visual loss includes two components and limited resolving power or acuity, a blur that can't be eliminated with a simple
LIGHT REFLECTION AND REFRACTION
QUESTION BANK IN SCIENCE CLASS-X (TERM-II) 10 LIGHT REFLECTION AND REFRACTION CONCEPTS To revise the laws of reflection at plane surface and the characteristics of image formed as well as the uses of reflection
1. You stand two feet away from a plane mirror. How far is it from you to your image? a. 2.0 ft c. 4.0 ft b. 3.0 ft d. 5.0 ft
Lenses and Mirrors 1. You stand two feet away from a plane mirror. How far is it from you to your image? a. 2.0 ft c. 4.0 ft b. 3.0 ft d. 5.0 ft 2. Which of the following best describes the image from
5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy
5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy Resolution of optical microscope is limited by diffraction. Light going through an aperture makes diffraction
P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)
INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as
A VERYbrief history of the confocal microscope 1950s
Confocal Microscopy Confocal Microscopy Why do we use confocal microscopy? A brief history of the confocal microscope Advantages/disadvantages of a confocal microscope Types of confocal microscopes The
Convex Mirrors. Ray Diagram for Convex Mirror
Convex Mirrors Center of curvature and focal point both located behind mirror The image for a convex mirror is always virtual and upright compared to the object A convex mirror will reflect a set of parallel
THE BOHR QUANTUM MODEL
THE BOHR QUANTUM MODEL INTRODUCTION When light from a low-pressure gas is subject to an electric discharge, a discrete line spectrum is emitted. When light from such a low-pressure gas is examined with
A Guide to Acousto-Optic Modulators
A Guide to Acousto-Optic Modulators D. J. McCarron December 7, 2007 1 Introduction Acousto-optic modulators (AOMs) are useful devices which allow the frequency, intensity and direction of a laser beam
MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL
Introduction With your purchase of an MT-30/MT-90 series type microscope you have chosen for a quality product. The MT-30/MT-90 series type microscopes are developed for use at schools and laboratories.
Lenses and Telescopes
A. Using single lenses to form images Lenses and Telescopes The simplest variety of telescope uses a single lens. The image is formed at the focus of the telescope, which is simply the focal plane of the
Preface Light Microscopy X-ray Diffraction Methods
Preface xi 1 Light Microscopy 1 1.1 Optical Principles 1 1.1.1 Image Formation 1 1.1.2 Resolution 3 1.1.3 Depth of Field 5 1.1.4 Aberrations 6 1.2 Instrumentation 8 1.2.1 Illumination System 9 1.2.2 Objective
O6: The Diffraction Grating Spectrometer
2B30: PRACTICAL ASTROPHYSICS FORMAL REPORT: O6: The Diffraction Grating Spectrometer Adam Hill Lab partner: G. Evans Tutor: Dr. Peter Storey 1 Abstract The calibration of a diffraction grating spectrometer
PUMPED Nd:YAG LASER. Last Revision: August 21, 2007
PUMPED Nd:YAG LASER Last Revision: August 21, 2007 QUESTION TO BE INVESTIGATED: How can an efficient atomic transition laser be constructed and characterized? INTRODUCTION: This lab exercise will allow
Experiment 3 Lenses and Images
Experiment 3 Lenses and Images Who shall teach thee, unless it be thine own eyes? Euripides (480?-406? BC) OBJECTIVES To examine the nature and location of images formed by es. THEORY Lenses are frequently
RAY OPTICS II 7.1 INTRODUCTION
7 RAY OPTICS II 7.1 INTRODUCTION This chapter presents a discussion of more complicated issues in ray optics that builds on and extends the ideas presented in the last chapter (which you must read first!)
1 of 9 2/9/2010 3:38 PM
1 of 9 2/9/2010 3:38 PM Chapter 23 Homework Due: 8:00am on Monday, February 8, 2010 Note: To understand how points are awarded, read your instructor's Grading Policy. [Return to Standard Assignment View]
Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money
Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money Lasers became the first choice of energy source for a steadily increasing number of applications in science, medicine
Chapter 12 Filters for FISH Imaging
Chapter 12 Filters for FISH Imaging Dan Osborn The application of in situ hybridization (ISH) has advanced from short lived, non-specific isotopic methods, to very specific, long lived, multiple color
View of ΣIGMA TM (Ref. 1)
Overview of the FESEM system 1. Electron optical column 2. Specimen chamber 3. EDS detector [Electron Dispersive Spectroscopy] 4. Monitors 5. BSD (Back scatter detector) 6. Personal Computer 7. ON/STANDBY/OFF
Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages 291 294. Equipment Needed
Theory Refer to your Lab Manual, pages 291 294. Geometrical Optics Equipment Needed Light Source Ray Table and Base Three-surface Mirror Convex Lens Ruler Optics Bench Cylindrical Lens Concave Lens Rhombus
CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging
CSCI 4974 / 6974 Hardware Reverse Engineering Lecture 8: Microscopy and Imaging Data Acquisition for RE Microscopy Imaging Registration and stitching Microscopy Optical Electron Scanning Transmission Scanning
Realization of a UV fisheye hyperspectral camera
Realization of a UV fisheye hyperspectral camera Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM Outline Purpose of the instrument Required specs Hyperspectral technique Optical
Reflection and Refraction
Equipment Reflection and Refraction Acrylic block set, plane-concave-convex universal mirror, cork board, cork board stand, pins, flashlight, protractor, ruler, mirror worksheet, rectangular block worksheet,
Optics. Kepler's telescope and Galileo's telescope. f 1. f 2. LD Physics Leaflets P5.1.4.2. Geometrical optics Optical instruments
Optics Geometrical optics Optical instruments LD Physics Lealets P5.1.4.2 Kepler's telescope and Galileo's telescope Objects o the experiment g Veriying that the length o a telescope is given by the sum
A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.
As seen in Photonics Spectra June 2006: A NEW LOOK AT RISLEY PRISMS By Craig Schwarze Senior Systems Engineer OPTRA Inc. Introduction With laser beams finding more and more applications that require aiming
Fluorescence Microscopy for an NMR- Biosensor Project
Fluorescence Microscopy for an NMR- Biosensor Project Ole Hirsch Physikalisch-Technische Bundesanstalt Medical Optics Abbestr. -1, 10587 Berlin, Germany Overview NMR Sensor Project Dimensions in biological
Alignement of a ring cavity laser
Alignement of a ring cavity laser 1 Introduction This manual describes a procedure to align the cavity of our Ti:Sapphire ring laser and its injection with an Argon-Ion pump laser beam. The setup is shown
Crystal Optics of Visible Light
Crystal Optics of Visible Light This can be a very helpful aspect of minerals in understanding the petrographic history of a rock. The manner by which light is transferred through a mineral is a means
Synthetic Sensing: Proximity / Distance Sensors
Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,
Diffraction of Laser Light
Diffraction of Laser Light No Prelab Introduction The laser is a unique light source because its light is coherent and monochromatic. Coherent light is made up of waves, which are all in phase. Monochromatic
PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.
PHYS 222 Spring 2012 Final Exam Closed books, notes, etc. No electronic device except a calculator. NAME: (all questions with equal weight) 1. If the distance between two point charges is tripled, the
OPTICAL IMAGES DUE TO LENSES AND MIRRORS *
1 OPTICAL IMAGES DUE TO LENSES AND MIRRORS * Carl E. Mungan U.S. Naval Academy, Annapolis, MD ABSTRACT The properties of real and virtual images formed by lenses and mirrors are reviewed. Key ideas are