Zeiss 780 Training Notes
|
|
|
- Bruce Dean
- 9 years ago
- Views:
Transcription
1 Zeiss 780 Training Notes
2 780 Start Up Sequence Do you need the argon laser, 458,488,514nm lines? No Turn on the Systems PC Switch Turn on Main Power Switch Yes Turn on the laser main power switch and turn the key ¼ turn to the right. Please note, all other lasers are turned on within the software. Push the toggle switch to the run position Turn on X-cite lamp Yes Wait Turn on the PC, log in to your account Are you using the argon laser? No Load your configuration No Is the green light on? Yes Turn on the Components Switch and wait until filters have stopped moving. Increase power until red light comes on Start Zen Software
3 Zen 2010 Double click the Zen780 icon on the desktop. Select Start System from the Zen 2010 login window. This will start up the hardware and software. Alternatively, Image Processing is for using the system offline, and this mode will ignore all the hardware components.
4 Zen workspace The workspace is very large so give yourself room. It is designed to step you through initially looking at your specimen via the Oculars tab, to acquiring images via the Acquire tab. The remaining tabs add advanced features, FCS, off-line Processing and Maintenance options. The workspace configuration and your sample configuration can be stored separately. In addition, your sample configurations can be easily retrieved from the Reuse function when you have an image loaded in the workspace.
5 Transmitted light Source and shutter Ocular Tab The Ocular tab gives you access to the microscope for previewing your sample. Select Online to make the microscope functional. At the top of the panel, you can open and close the Fluorescent Shutter. in the Configuration pane, you can create shortcut buttons for using transmitted and fluorescent light. Fluorescent light Source and shutter Environmental Controls Objectives Ocular panel This panels allows you to configure the microscope so you can view your image under transmitted or fluorescent light; DAPI, FITC, or Rhodamine filter sets. Objectives There is a dedicated set of objectives for the 780 however it is possible to use other objectives that are available in the center. Image Once you have located you image, be sure to center it in the field of view as the scan area on the system is very small and you want to be sure to capture the area you are interested in.
6 Acquisition Tab When using the Acquisition tab, always be sure to first select View>Show All, and check Show Manual Tools. The Zen software tends to hide information that is useful for capturing your images so by making these selections you will have all the tools necessary for your work. For example, the Setup Manager, which gives you access to the lasers will be hidden unless Show Manual tools is selected. Smart Setup Until you are familiar with the workings of the 780, the best and easiest way to get started is to use the Smart Setup tool. Select your dye(s) from the drop down menu. The software will automatically pseudo-color your dyes; you can change the suggested color from the right down arrow. Depending on your imaging needs, the Smart Setup will offer you up to four different configurations for imaging your sample: Fastest, Best Signal, Best Compromise, and Linear Unmixing. Whatever configurations you are presented with, you can always manually modify the configuration in the Light Path. Make your selection and press the Apply button to implement the configuration.
7 Smart Setup (continued) Fastest: Acquires the image with simultaneous excitation and detection of the different probes. This option may produce bleed through between the different channels. Best Signal: This will usually configures the system such that each probe is scanned one at a time, and then over lays the images as one at the end of the scan routine. This will prevent bleed through between the probes however, this subjects your sample to be exposed to the laser light for X times, depending on the number of probes you are using, which can lead to bleaching or other laser induced damage. Best Compromise: This option will often combine two probes into a signal track and image the other probe(s) separately. This may or may not avoid bleed through between the probes depending on the nature of the probes being used and it may also be the same option as the Fastest configuration, it all depends on the probes. Linear Unmixing (not pictured): This option creates a confirmation for computationally subtracting bleed through between channels after you acquire pure spectral profiles of the probes you are using.
8 Acquisition Tab You can work your way down the acquisition tab as you explore its functions. New - opens a new image capture window. Auto Exposure - Computer will optimize the master gain and offset for the given laser power and pinhole size. Live - fast scan for previewing image. Continuous - scan that can be regulated fast or slow. Snap - Single scan. Note, when you initiate a scan, that particular button will be converted to the Stop button. Advanced Features Select from Z-stack, Time Series, Bleaching, Tile Scan, Positions, and Regions. You must initiate the scans using these functions with the Start Experiment button.
9 Acquisition Tab The Acquisition tab initializes with the submenus collapsed; be sure to select the arrow to expand each submenu. Setup Manager Laser Imaging Setup Light Path Open/close Submenu with down arrow. Online Acquisition Acquisition Mode Channels Focus Stage Multidimensional Acquisition Information on Experiment Auto Save Click arrow to detach/attach panel and open it in main workspace.
10 Acquisition Tab Setup Manager Laser The 780 offers the following laser line selections: Diode 405nm (30mW) Diode 440nm (15mW) Argon 458nm, 488nm, 514nm (25mW) Helium-Neon 633nm (5mW) Chameleon (tunable two-photon laser) nm (1W) The argon and Chameleon lasers are the only lasers powered on outside the software. The software is smart enough to prompt you to turn on a laser when you select it from the Smart Setup option, however if you manually need to turn on a laser you should do so with this panel.
11 Acquisition Tab Setup Manager Imaging Setup Mode Channel Mode - x-y scanning configuration. Lambda Mode Used to create spectral profiles of dyes Online Fingerprinting applies spectral profile configuration to dye, to correct for bleed through issues, as it is scanned Switch track every Line Tracks are switched line by line. Laser line, laser intensity and channels can be changed between tracks. Frame Tracks are switched frame by frame. Laser line and intensity, filters, beam splitters, gain and offset, and pinhole setting can all be changed between tracks. Frame Fast scanning procedure can be made faster. Only the laser line intensity and Amplifier offset can be changed between tracks.
12 Acquisition Tab Setup Manager Imaging Setup (cont.) Track refers to the dye(s) that are being detected and enables or disables them by their selection. A maximum of four tracks can be created. The track displays the dye, laser line excitation and the emission detection range. The actual configuration is defined in the Light Path panel, which is found below. Light Path LSM Single Photon Mode Non Descanned Two Photon Mode Channel Mode - x-y scanning configuration. Lambda Mode Used to create spectral profiles of dyes Online Fingerprinting applies spectral profile configuration to dye, to correct for bleed through issues, as it is scanned.
13 Detectors Acquisition Tab (cont.) Setup Manager (cont.) Light Path (cont.) Emission Detection Dichroics Excitation Source Options for Configuring the Light Path Dye and pseudo-color display Detector select from Ch1 or Ch2 (standard PMTs) QUASAR detectors ChS 1-8, or transmitted light detector ChD (not confocal). Emission Range Laser either visible or invisible (UV) and set attenuation values (% transmission) Main dichroic beam splitter Transmitted Light Detector
14 Acquisition Tab Online Acquisition Acquisition Mode Objective change objectives from here Scan Mode Frame, Line, Spot Frame Size defaults to 512 x 512. Select Optimal for appropriate number of pixels depending on numerical aperture and excitation wavelength. Speed adjust scan speed. A higher speed with averaging yields results with the best signal-to-noise ratio. Use slower scan speeds for better images, but be aware of photobleaching. Averaging improves image by increasing the signal-to-noise ratio. Select from Line or Frame averaging and select the number to average by. Averaging helps to reduce photobleaching. Bit Depth select from 8 bit (256 gray levels), 12 bit (4096 gray levels), or 16 bit (65536 gray levels). Be sure your software can handle the information. 12 and 16 bit images are recommended for publication and quantitative measurements. Scan Area set the microscopic zoom
15 Acquisition Tab Online Acquisition Channels The track for the Channel must be active and selected in order to make changes. Lasers turn lasers on and off and modify laser power. Pinhole set pinhole to 1 AU (airy unit) to achieve best z resolution based on the excitation wavelength and objective numerical aperture. Be sure to match the section thickness when scanning multiple channels. Mode Integration and Photon Counting Gain (Master) amplifies the voltage on the photomultiplier tube; regulates brightness of the image Digital Offset sets background/threshold level of the image Digital Gain post acquisition enhancement of the gain signal.
16 Select range indicator Minimum intensity Acquisition Tab Online Acquisition Channels (cont.) Remember, when acquiring your images, you want to be within the dynamic range of the detector. This is especially critical when collecting images that will be used for quantitative analysis. Use the Range Indicator to adjust the gain and offset. Blue= minimum, Red= maximum (0 and 255 for 8 bit image, 0 and 4095 for 12 image, 0 and for 16 bit image.) Adjust Detector Gain and Amplifier Offset to remove red and blue pixels. Minimum should be ~ gray levels above 0 and Maximum should be gray levels below 255 for an 8 bit image. You can scale this accordingly for 12 and 16 bit images. Maximum intensity
17 Acquisition Tab Online Acquisition Focus The 780 offers the ability to manually control the focus or to use the software to control the focus. Step size set a fixed step size, in microns. Move up or down in the focal plane based on that step size. Z-position specifies location of focal plane. Home zeros the focal position. Work returns the objective to the desired focus, from the previous sample. Load lowers the objective so the user can change the sample. Moves according to set step size. Moves according to set step size. Stage The 780 allows you to manually control the stage via the joy stick or to use the software to control the stage. x-y coordinates indicates stage position. Step move specified step size, in microns. Set zero establish a zero point (0,0) on the stage Move to zero move to the zero point on the stage.
18 Acquisition Tab Online Acquisition Multidimensional Acquisition Z-stack Collect multiple images of different focal planes within a single file for 3-D analysis/display. Set Last mark ending point of stack Set First mark starting point of stack Slices displays how many slices will make up the stack Interval distance between each slice Optimal calculates each slice to be ½ the z-resolution for proper Nyquist sampling. Keep Interval/Slice decided if the stack should be based on the interval thickness or the number of slices. Optimize Section and Step Match Pinhole for multiple wavelengths ensure that the pinholes are yielding the same section thickness. Optimal - calculates each slice to be ½ the z-resolution for proper Nyquist sampling. Undo clears selection
19 Acquisition Tab Online Acquisition Multidimensional Acquisition additional options Time Series - Collect a series of images based on a time interval. Bleaching module for FRAP (fluorescent recovery after photobleaching.) Tile Scan create larger images by tiling smaller images together. Positions record stage coordinates to return to Regions drawing tools used to isolate particular scan areas of the sample.
20 Image Display Images that are acquired are displayed in the central field of the software and their display settings can be modified. Options for viewing your images, depending on how they are acquired include: 2D x-y view of image Split view multi-channel images as individual and overlay displays. Gallery display of z-stack or time series images.
21 Image Display (cont.) Z-Stack Display options Ortho orthogonal display, xy, yz and xz options Cut display a particular slice of stack and have options for manipulating that slice 2.5D layered depth display 3D reconstruction of z-stack
22 Image Display (cont.) Histogram display of image intensities and their frequencies within the image. Co-localization display spatial overlap of fluorescent regions in different channels Profile display pixel intensities along defined regions or lines. Unmixing separate fluorescent overlap between channels RICS (Raster Scanning Image Correlation Spectroscopy) determine molecular speeds and concentrations. Information summary of image file.
23 Image Display (cont.) Tabs The display options will vary depending on the image data and the advanced features being displayed. Dimensions Z position for stack Zoom digital zoom Channels range indicator, pseudo-colors, turn on/off channels displayed Display Adjust screen display with brightness, contrast and gamma Overlay Image overlays, i.e. measuring, drawing elements.
24 File save Saving Images Images are saved as.lsm files. The files are tif files that contain the acquisition parameters stored in the header of the file. You can always export the files as different file types however it is recommended to always save the.lsm file, your raw image data file. Images are to be saved to your lab s partition on the remote server: \\cfs02.cam.uchc.edu\home\cam\account_username
25 Are you using the argon laser? Yes Decrease the power; put the toggle switch in the stand-by position No Last User? Verified Next User Exit the software, internal lasers will turn off when exiting, log-off and shut down PC. Turn off System PC and Components Switches, and Main Switch. Last User? Turn off X-cite Turn off laser power supply Verified Next User Exit the software, internal lasers will turn off when exiting, log-off, leave system on. Yes Turn off X-cite Is laser cool? Turn the key back to the 12:00 position. Wait until system has cooled. During cool down, ~ 3 minutes Exit the software, internal lasers will turn off when exiting, log-off and shut down PC. No Exit the software, internal lasers will turn off when exiting, log-off, leave system on. Please check the sign up after you are finished. If someone is after you, verify that they are coming. If you can t do this then shut the system down. 780 Shut down sequence
Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION
Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION This manual is the FIRST section of a THREE part Leica TCS - SP5 User Guide edited by Donald Pottle Leica True Confocal
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL Robert Bagnell 2006 This tutorial covers the following CLSM topics: 1) What is the optical principal behind CLSM? 2) What is the spatial resolution in X, Y,
Webex-based remote instrument control guide
Webex-based remote instrument control guide 1) Once a microscopic imaging experiment is scheduled, the host (i.e., Hunter Bioimaging Facility) will send an email containing a Webex meeting link to the
The How Do Guide to AxioVision. Author: Brian Svedberg Image Analysis Specialist Carl Zeiss MicroImaging, Inc.
The How Do Guide to AxioVision Author: Brian Svedberg Image Analysis Specialist Carl Zeiss MicroImaging, Inc. How do I grab a single image? How do I grab a single image? Click on the Camera icon to switch
Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012
Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012 You are sitting at your microscope working at high magnification trying to sort out the three-dimensional compartmentalization
NIS-Elements Viewer. User's Guide
NIS-Elements Viewer User's Guide Publication date 10.09.2013 v. 4.20.00 Laboratory Imaging, s. r. o., Za Drahou 171/17, CZ - 102 00 Praha 10 No part of this publication may be reproduced or transmitted
Zeiss 710 Confocal Microscope User Guide
Cornell University - Biotechnology Resource Center Imaging Facility Zeiss 710 Confocal Microscope User Guide B46 Weill Hall BRC Imaging Facility 8-6-2014 Table of Contents Startup General Procedure 2 Microscope
Information about ZEN 2009 Service Pack 2
Information about ZEN 2009 Service Pack 2 Build 5.5.0.443, SMT 5.5.3.1 The Service Pack 2 is a full installation for ZEN 2009 and ZEN 2009 SP1. It is required that ZEN 2009 is available on the system before
OPERATING INSTRUCTIONS Nikon TiE Deconvolution Microscope CCRB 1-220G
OPERATING INSTRUCTIONS Nikon TiE Deconvolution Microscope CCRB 1-220G Conventions Through these notes bold font refers to a software button and italics refer to a hardware switch. The software makes extensive
ZEISS Microscopy Course Catalog
ZEISS Microscopy Course Catalog ZEISS Training and Education Expand Your Possibilities Practical microscopy training has a long tradition at ZEISS. The first courses were held in Jena as early as 1907,
Basic 3D reconstruction in Imaris 7.6.1
Basic 3D reconstruction in Imaris 7.6.1 Task The aim of this tutorial is to understand basic Imaris functionality by performing surface reconstruction of glia cells in culture, in order to visualize enclosed
Recording the Instrument Response Function of a Multiphoton FLIM System
Recording the Instrument Response Function of a Multiphoton FLIM System Abstract. FLIM data analysis in presence of SHG signals or extremely fast decay components requires the correct instrument response
Takeoff Guide Tutorial to get started with the AxioVision Imaging System (Based on Release 4.7.2 December 2008)
Takeoff Guide Tutorial to get started with the AxioVision Imaging System (Based on Release 4.7.2 December 2008) This Takeoff Guide has been prepared for Carl Zeiss by Imaging Associates Ltd. www.imas.co.uk
The Applied Imaging Cytogenetic Workstation
The Applied Imaging Cytogenetic Workstation Introduction to the Genus F.I.S.H. Imaging System. The Genus Imaging System is a powerful and easy way to capture Fluorescence in-situ Hybridisation pictures
Navios Quick Reference
Navios Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic tasks
Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...
Confocal Microscopy and Atomic Force Microscopy (AFM) of biofilms A very brief primer... Fundamentals of Confocal Microscopy Based on a conventional fluorescence microscope Fluorescent Microscope Confocal
User Manual. cellsens LIFE SCIENCE IMAGING SOFTWARE
User Manual cellsens LIFE SCIENCE IMAGING SOFTWARE Any copyrights relating to this manual shall belong to Olympus Soft Imaging Solutions GmbH. We at Olympus Soft Imaging Solutions GmbH have tried to make
SA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
Open icon. The Select Layer To Add dialog opens. Click here to display
Mosaic Introduction This tour guide gives you the steps for mosaicking two or more image files to produce one image file. The mosaicking process works with rectified and/or calibrated images. Here, you
Multi Client (Integration)
Multi Client (Integration) Installation and User s Guide Ver 12.10.x *All contents of this document may change without prior notice. INDEX 1. Index 01 2. Introduction 02 3. Installation 03 4. Using Multi
3. TCS - SP5 Off-Line Confocal Work Stations
3. TCS - SP5 Off-Line Confocal Work Stations 1 Processing image data for 3D rotations and movies takes substantial time on our confocal microscope work station. Clients are asked to transfer data to our
5. Tutorial. Starting FlashCut CNC
FlashCut CNC Section 5 Tutorial 259 5. Tutorial Starting FlashCut CNC To start FlashCut CNC, click on the Start button, select Programs, select FlashCut CNC 4, then select the FlashCut CNC 4 icon. A dialog
Operating Manual for UVEX-p (JAN Scientific, Inc. Aug 2014)
Operating Manual for UVEX-p (JAN Scientific, Inc. Aug 2014) [The beige shaded areas introduce the user interface in detail. For turn on and run operation, you may skip these descriptions. The blue shaded
DVS Net (Integration)
DVS Net (Integration) Installation and User s Guide Ver 11.10.x Digital Video Security System Digital Video Recorder www.tuniss.com PLEASE CALL TUNISS COMPUTER AT: 650-401-6138 FOR ANY QUASTIONS REGARDING
Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!
Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available! Arrayit SpotLight Two-Color Microarray Scanners provide the market s most affordable
Sharing Software. Chapter 14
Chapter 14 14 Sharing Software Sharing a tool, like a software application, works differently from sharing a document or presentation. When you share software during a meeting, a sharing window opens automatically
MASKS & CHANNELS WORKING WITH MASKS AND CHANNELS
MASKS & CHANNELS WORKING WITH MASKS AND CHANNELS Masks let you isolate and protect parts of an image. When you create a mask from a selection, the area not selected is masked or protected from editing.
Windows XP Pro: Basics 1
NORTHWEST MISSOURI STATE UNIVERSITY ONLINE USER S GUIDE 2004 Windows XP Pro: Basics 1 Getting on the Northwest Network Getting on the Northwest network is easy with a university-provided PC, which has
Shimadzu UV-VIS User s Guide
Shimadzu UV-VIS User s Guide 1) Push the F4 button on the UV-VIS instrument keypad. This will enable PC control. Push the F4 Button 2) Log into the UV-VIS software with your username and password. 3) After
Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH
g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 [email protected], http://www.gtec.at Building a Simulink model for real-time
Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2)
Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2) Software Version 1.9. 2902 To check that you have the latest version, go to the DOWNLOADS section of our Web
ACS CLIENT SOFTWARE USER MANUAL
ACS CLIENT SOFTWARE USER MANUAL 1 ACS USER GUIDE 1.1 System Requirement Recommended System Requirement OS CPU VGA RAM HDD WindowXP, Vista Pentium 4, 2Ghz 1024*768, 64MB 24bit color graphic card 1GB 20MB
NVMS-1200. User Manual
NVMS-1200 User Manual Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Install and Uninstall... 1 1.2.1 Install the Software... 1 2 Login Software... 3 2.1 Login... 3 2.2 Control Panel Instruction...
DIGICLIENT 8.0 Remote Agent Software
DIGICLIENT 8.0 Remote Agent Software MODEL: D17800 Series Instruction Manual English Version 1.0 Copyright 2007 Digimerge Technologies Inc Table of Contents Table of Contents About the DigiClient 8.0...
End User Guide. July 22, 2015
End User Guide July 22, 2015 1 Contents Quick Start 3 General Features 4 Mac/Windows Sharing 15 Android/ ios Sharing 16 Device Compatibility Guide 17 Windows Aero Theme Requirement 18 2 Quick Start For
Central Management Software CV3-M1024
Table of Contents Chapter 1. User Interface Overview...5 Chapter 2. Installation...6 2.1 Beginning Installation...6 2.2 Starting the CMS software...10 2.3 Starting it from the Start menu...10 2.4 Starting
COMPENSATION MIT Flow Cytometry Core Facility
COMPENSATION MIT Flow Cytometry Core Facility Why do we need compensation? 1) Because the long emission spectrum tail of dyes causes overlap like with the fluorophores FITC and PE. 2) For sensitivity reasons,
The serial port is another kind of transmission mode in some outdated PC as a supplementary in failure of USB transmission.
Page 1 of 21 OWON Oscilloscope Installation and Use Guide Welcome to use Oscilloscope analysis software. The kind of communication software is use to acquire, store, analyze and display the data. The instruction
Instructions for Use. CyAn ADP. High-speed Analyzer. Summit 4.3. 0000050G June 2008. Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835
Instructions for Use CyAn ADP High-speed Analyzer Summit 4.3 0000050G June 2008 Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835 Overview Summit software is a Windows based application that
MetaMorph Software Basic Analysis Guide The use of measurements and journals
MetaMorph Software Basic Analysis Guide The use of measurements and journals Version 1.0.2 1 Section I: How Measure Functions Operate... 3 1. Selected images... 3 2. Thresholding... 3 3. Regions of interest...
3D Viewer. user's manual 10017352_2
EN 3D Viewer user's manual 10017352_2 TABLE OF CONTENTS 1 SYSTEM REQUIREMENTS...1 2 STARTING PLANMECA 3D VIEWER...2 3 PLANMECA 3D VIEWER INTRODUCTION...3 3.1 Menu Toolbar... 4 4 EXPLORER...6 4.1 3D Volume
STEPfwd Quick Start Guide
CERT/Software Engineering Institute June 2016 http://www.sei.cmu.edu Table of Contents Welcome to STEPfwd! 3 Becoming a Registered User of STEPfwd 4 Learning the Home Page Layout 5 Understanding My View
FX-BTCVT Bluetooth Commissioning Converter Commissioning Guide
FX-BTCVT Bluetooth Commissioning Converter Commissioning Guide FX-BTCVT-1 (Bluetooth Commissioning Converter) Code No. LIT-12011665 Issued December 5, 2014 Refer to the QuickLIT website for the most up-to-date
CDVS-7000 Series Remote Software Users Guide
CDVS-7000 Series Remote Software Users Guide Crest Electronics, Inc. Version 12.1005 Remote Surveillance Program The remote surveillance program enables users of the Crest 7000 series DVRs to connect remotely
Video Tracking Software User s Manual. Version 1.0
Video Tracking Software User s Manual Version 1.0 Triangle BioSystems International 2224 Page Rd. Suite 108 Durham, NC 27703 Phone: (919) 361-2663 Fax: (919) 544-3061 www.trianglebiosystems.com Table of
WPI Laser Cutter User Guide
WPI Laser Cutter User Guide The laser cutter is capable of cutting and engraving two-dimensional drawings in various materials including wood and plastic. The laser cutter owned by the WPI Department of
Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.
1234 Hach Hall 515-294-5805 www.cif.iastate.edu Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V. Location: Contact: 1240 Hach Hall Steve Veysey, 1234 Hach Hall Safety All researchers working
Leica Confocal Software LCS. User manual (for Leica TCS SP2 systems)
Leica Confocal Software LCS User manual (for Leica TCS SP2 systems) 1 Table of Contents 1 Table of Contents...2 2 The Leica Confocal Software: An overview...7 2.1 Starting the software...7 2.2 The experimental
Contents. 1.2 Software Installation... 1
Software Manual Contents 1 Software Installation... 1 1.1 Overview...1 1.2 Software Installation... 1 2 Introduction To Basic Function...5 2.1 Login System... 5 2.2 CMS Operating Interface...5 2.2.1 Operating
Lab 1: The Digital Oscilloscope
PHYSICS 220 Physical Electronics Lab 1: The Digital Oscilloscope Object: To become familiar with the oscilloscope, a ubiquitous instrument for observing and measuring electronic signals. Apparatus: Tektronix
NVMS - 1000 USER MANUAL. Version 2.1.0
NVMS - 1000 USER MANUAL Version 2.1.0 Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall
Auto Clicker Tutorial
Auto Clicker Tutorial This Document Outlines Various Features of the Auto Clicker. The Screenshot of the Software is displayed as below and other Screenshots displayed in this Software Tutorial can help
Using Image J to Measure the Brightness of Stars (Written by Do H. Kim)
Using Image J to Measure the Brightness of Stars (Written by Do H. Kim) What is Image J? Image J is Java-based image processing program developed at the National Institutes of Health. Image J runs on everywhere,
Central Management System (CMS) USER MANUAL
Central Management System (CMS) USER MANUAL LEGAL INFORMATION Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission
ivms-4200 Client Software Quick Start Guide V1.02
ivms-4200 Client Software Quick Start Guide V1.02 Contents 1 Description... 2 1.1 Running Environment... 2 1.2 Surveillance System Architecture with an Performance of ivms-4200... 3 2 Starting ivms-4200...
1. Introduction... 3. 2.Fixture exterior view... 3. 3. Connecting the Robe Universal Interface... 4. 3.1 Software update of the fixture...
1 Table of contests 1. Introduction... 3 2.Fixture exterior view... 3 3. Connecting the Robe Universal Interface... 4 3.1 Software update of the fixture... 4 3.2 Connecting a DMX console to the Media Fusion...
ImagineWorldClient Client Management Software. User s Manual. (Revision-2)
ImagineWorldClient Client Management Software User s Manual (Revision-2) (888) 379-2666 US Toll Free (905) 336-9665 Phone (905) 336-9662 Fax www.videotransmitters.com 1 Contents 1. CMS SOFTWARE FEATURES...4
Name: Due: September 21 st 2012. Physics 7230 Laboratory 3: High Resolution SEM Imaging
Name: Due: September 21 st 2012 Physics 7230 Laboratory 3: High Resolution SEM Imaging 1. What is meant by the term resolution? How does this differ from other image variables, such as signal to noise
User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment.
User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment. (last updated 03/17/2016) This guide is for use of the Cary 5000 with the DRA only. For use without the DRA as a standard
ivms-4500(windows Mobile) Mobile Client Software User Manual Version 1.0
ivms-4500(windows Mobile) Mobile Client Software User Manual Version 1.0 Thank you for purchasing our product. This manual applies to ivms-4500 (Windows Mobile) mobile client software, please read it carefully
Chapter 12 Filters for FISH Imaging
Chapter 12 Filters for FISH Imaging Dan Osborn The application of in situ hybridization (ISH) has advanced from short lived, non-specific isotopic methods, to very specific, long lived, multiple color
Pictorial User s Guide
S-T IMAGING Pictorial User s Guide Copyright 2008 ST Imaging, Inc. a division of Digital Check Corp. All Rights Reserved. Table of Contents Getting Started... 1 Adjust for Viewing...1 Loading Microfilm...2
A VERYbrief history of the confocal microscope 1950s
Confocal Microscopy Confocal Microscopy Why do we use confocal microscopy? A brief history of the confocal microscope Advantages/disadvantages of a confocal microscope Types of confocal microscopes The
Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)
Weather Direct Displays show Lost Forecast (blank boxes in the picture icons) Many routine events can cause a Lost Forecast situation. Examples include: Power outage Change batteries Internet down in your
The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic
1 AGENDA Product roadmap...3 Computer based system: PLATINUM..5 XPLORER.6 ESSENTIAL..7 Specifications Computer based system..8 Configuration Computer based system... 9 Software Computer based system...10
1. Instrument Layout pg 2. 2. Summit Overview pg 3. 3. Data Storage and Data Files pgs 6-7. 4. Saving Data pg 7. 5. Start Up pg 8
Table of Contents 1. Instrument Layout pg 2 2. Summit Overview pg 3 3. Data Storage and Data Files pgs 6-7 4. Saving Data pg 7 5. Start Up pg 8 6. Choosing and Naming Parameters pg 9 7. Creating Histograms
Sharing Presentations, Documents, and Whiteboards
Chapter 19 19 Sharing Presentations, Documents, and Whiteboards Your user role in an event determines your level of sharing. Whichever role you take, the following table describes the basic tasks associated
Important Notes for WinConnect Server VS Software Installation:
Important Notes for WinConnect Server VS Software Installation: 1. Only Windows Vista Business, Windows Vista Ultimate, Windows 7 Professional, Windows 7 Ultimate, Windows Server 2008 (32-bit & 64-bit),
TUTORIAL 4 Building a Navigation Bar with Fireworks
TUTORIAL 4 Building a Navigation Bar with Fireworks This tutorial shows you how to build a Macromedia Fireworks MX 2004 navigation bar that you can use on multiple pages of your website. A navigation bar
Introduction. POP and IMAP Servers. MAC1028 June 2007
MAC1028 June 2007 Getting Started with Thunderbird 2.0 For Macintosh OS X Author: John A. Montgomery Adapted to OS X by: Peter Lee Revised by Mitchell Ochi and Deanna Pasternak Introduction...1 POP and
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
1. Installing The Monitoring Software
SD7000 Digital Microphone Monitor Software manual Table of Contents 1. Installing The Monitor Software 1.1 Setting Up Receivers For Monitoring 1.2 Running The Application 1.3 Shutdown 2. The Detail Monitoring
Snap 9 Professional s Scanning Module
Miami s Quick Start Guide for Using Snap 9 Professional s Scanning Module to Create a Scannable Paper Survey Miami s Survey Solutions Snap 9 Professional Scanning Module Overview The Snap Scanning Module
Appendix A. CMS(Client Management Software)
Appendix A. CMS(Client Management Software) A-1. Install CMS for Windows PC CMS is a program for communication between DVR and PC to control signal and video. Insert the enclosed CD, and go to CD-ROM Drive
Professional Surveillance System User s Manual
Professional Surveillance System User s Manual \ 1 Content Welcome...4 1 Feature...5 2 Installation...6 2.1 Environment...6 2.2 Installation...6 2.3 Un-installation...8 3 Main Window...9 3.1 Interface...9
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Some limitations (disadvantages) of NSOM A trade-off
SOS SO S O n O lin n e lin e Bac Ba kup cku ck p u USER MANUAL
SOS Online Backup USER MANUAL HOW TO INSTALL THE SOFTWARE 1. Download the software from the website: http://www.sosonlinebackup.com/download_the_software.htm 2. Click Run to install when promoted, or alternatively,
Packet Tracer 3 Lab VLSM 2 Solution
Packet Tracer 3 Lab VLSM 2 Solution Objective Create a simulated network topology using Packet Tracer Design an IP addressing scheme using a Class B subnetwork address and VLSM Apply IP addresses to the
Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale
Nano-Spectroscopy Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale Since its introduction in the early 80 s, Scanning Probe Microscopy (SPM) has quickly made nanoscale imaging an affordable
1 ImageBrowser Software User Guide
1 ImageBrowser Software User Guide Table of Contents (1/2) Chapter 1 Try It! ImageBrowser Chapter 2 What is ImageBrowser? Chapter 3 Starting ImageBrowser... 4 Downloading Images to Your Computer... 9 Printing
Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab
Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab Room 213 Beckman Coulter DTX 880 Multimode Detector Information The Beckman Coulter DTX 880 Multimode Detector is
Model 288B Charge Plate Graphing Software Operators Guide
Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254
Installing Remote Desktop Connection
SETTING UP YOUR REMOTE DESKTOP This section will assist you in setting you Remote Desktop Connection. This will allow you to create an icon for easy access to your virtual desktop. DISCLAIMER: All images
A quick user guide for your LX Apollo DVR
A quick user guide for your LX Apollo DVR The LX Apollo series of DVR s is designed specially for the security and surveillance field and is an outstanding digital surveillance product. It has an embedded
GETTING STARTED WITH FLEXI-CLOUD
GETTING STARTED WITH FLEXI-CLOUD WELCOME TO FLEXI-CLOUD. Flexi-CLOUD is the "on-demand" licensing solution powered by MYRIAD-connect. This document explains how to install Flexi-CLOUD servers and how to
Atomic Force Microscope
Atomic Force Microscope (Veeco Nanoman) User Manual Basic Operation 4 th Edition Aug 2012 NR System Startup If the system is currently ON To start the NanoScope software, double-click the NanoScope startup
En Wireless Mobile Utility (Android) User s Manual. D610, D600, D7100, D5300, D5200, D3300, Df 0 2 26
1 En Wireless Mobile Utility (Android) User s Manual Install the Wireless Mobile Utility on your smart device (smartphone or tablet) to download pictures from a camera or take pictures remotely. The Wireless
Using Avaya Flare Experience for Windows
Using Avaya Flare Experience for Windows Release 9.0 Issue 02.01 September 2013 Contents Chapter 1: About Flare Experience... 5 About Flare Experience... 5 Main window... 6 Button descriptions... 10 Chapter
2012 Ward s Natural Science
2012 Ward s Natural Science Contents Recommended System Requirements...3 Additional Assistance...3 QUICK START GUIDE Installation Instructions...4 How It Works...5 Your First View...6 Navigating the Library...7
Example of SOP for IR Laser
Example of SOP for IR Laser Standard Operating Procedures (SOP) for Class 4 HPD semiconductor Laser Manufacturer HPD Building & Room Number EH&S 101 Model Number HPD-1/100/975 Laser Class 4 Serial Number
4 Troubleshooting Your Projector
4 Troubleshooting Your Projector If you experience problems with your projector, see the following troubleshooting tips. If the problem persists, contact Dell (see Contacting Dell on page 57). Problem
FrontDesk Installation And Configuration
Chapter 2 FrontDesk Installation And Configuration FrontDesk v4.1.25 FrontDesk Software Install Online Software Activation Installing State Related Databases Setting up a Workstation Internet Transfer
Microsoft Migrating to Access 2010 from Access 2003
In This Guide Microsoft Access 2010 looks very different, so we created this guide to help you minimize the learning curve. Read on to learn key parts of the new interface, discover free Access 2010 training,
WebEx Sharing Resources
WebEx Sharing Resources OTS PUBLICATION: WX0 REVISED: 4/8/06 04 TOWSON UNIVERSITY OFFICE OF TECHNOLOGY SERVICES =Shortcut =Advice =Caution Introduction During a WebEx session, the host has the ability
MULTI-CLIENT Remote Monitor Center. User manual
MULTI-CLIENT Remote Monitor Center User manual Contents 1.Multi-client introduction... 3 2.Main features... 4 3.Working Envoirment and installation... 4 4.Login... 4 5.Using procedures... Ошибка! Закладка
The service note describes the basic steps to install a ip camera for the DVR670
Tech note Description Adding IP camera to DVR670 General The service note describes the basic steps to install a ip camera for the DVR670 Steps involved: 1) Configuration Manager application 2) Camera
TouchKit Software User manual for Windows 7 Version: 5.10.5
TouchKit Software User manual for Windows 7 Version: 5.10.5 TouchKit V5.10.5 0 CONTENT CHAPTER 1. INSTALLING TOUCHKIT 2 CHAPTER 2. USING TOUCHKIT UTILITY...9 2.1 General...9 2.2 Tool...11 2.3 Setting...14
USER GUIDE Version 2.0
USER GUIDE Version 2.0 TABLE of CONTENTS Introduction... 3 Hardware Overview... 3 Software Overview... 4 DAYSHIFT Panel... 5 Settings Panel... 6 Setup Tab... 6 Configure... 6 Show User Guide... 6 Preview