ODU SPC. ODU Single Power Connector High Current Connector.
|
|
|
- Aubrey Horton
- 9 years ago
- Views:
Transcription
1 ODU Single Power Connector High Current Connector
2 ODU SPC Single Power Connector Applications: Renewable energy e.g. solar or wind power Industrial- and controlgear Power and emergency power supply Lightning technology Railway technology Labor Testing. Features: Single Power Connector Secure locking system Reliable connection under vibration Touch proof IP 2X. The latest version of this catalog is posted on our websites: All shown connectors are according to DIN EN 61984:2009 connectors without breaking capacity (COC). All data and specifications subject to change without notice: All dimensions in mm. All pictures are illustrations. This pdf document is interactive: Blue underlined texts lead to the appropriate sides in the catalog and/or to the appropriate Internet sites. Page 2
3 Table of contents Chapter from page 1 Product description 5 2 ODU SPC with push-pull locking 13 3 ODU SPC with push-pull locking protection class IP 50 and IP Special solutions 25 5 Accessories Tools and termination technologies Assembly instructions Technical information 41 7 Part number key and inquiry form 54 Page 3
4 Order information How to find the right connector: Choose on page 13 the type of connector. Release the relevant numbers or letters into the 19 position part number (Order form see last page). Choose coding, housing material, insulation body material, contact surface, termination, cross section and collet system in reference to the charts on page 22, 23 and 24. Release the relevant numbers or letters into the 19 position part number. Page 4
5 Product description Page 5
6 Product description Important issues at a glance The new product line SPC is a combination of the proven ODU lamella contacts and a robust housing with pushpull locking. Advantages: No accidental demating because of the push-pull locking Power Connector High voltage contact with touch proof IP 2X in unmated condition Nominal current up to 300 A Nominal voltage up to 1,000 V (with EMI protection on request) Protection class IP 50 or IP 67 in mated condition High number of mating cycles > 5,000 Operation temperature: 40 up to +140 C High economy: Economical processing because of crimp termination Economical combination (single contact and housing) Economical prices Robust housing Low mating and demating forces Housing non-magnetic High chemical resistance For use under harsh environmental conditions RoHS-Conform: The connector ODU SPC meets the demands of the 2002 / 95 / EG guideline. Page 6
7 Product description Push-pull locking principle Pulling on the cable or on the back nut causes the locking fingers to grip tighter into the groove inside receptacle. A separation is virtually impossible. Pulling on the outer plug housing disengages the locking fingers from the receptacle groove and the connector separates easily. The advantages of push-pull locking Quick and easy mating and locking Quick and easy separating Easy blind mating in difficult-to-reach places Less space required Definite and secure locking condition. Page 7
8 Product description Contact technology: ODU lamella contact The lamella contact consists of a stamped contact band with lamellas which is mounted into a turned carrier. The individual lamella ridges result in a multitude of contact points that guarantee a high level of contact stability and ensure optimal conductive characteristics. The adjusted contact force ensures low insertion and removal forces, and consequently a long service life with few signs of wear. Unmated Mated Carrier Socket Lamella A A Pin View A A If the contact diameter is 4 mm, for example, the ODU lamella contact results in a total of 18 contact points. Larger diameters correspondingly produce more contact points. Features / Advantages Low contact resistance Low fall of voltage High number of contact points High number of mating cycles / long product lifetime High ampacity Constant power transmission No loss of power. Page 8
9 Product description Construction ODU SPC Housing made out of plastic with push-pull locking: Protection class IP 50 / IP 67 (in mated condition) Touch proof IP2X (in unmated condition) Mechanical and colour keying possibilities. ODU Inline-Receptacle Insulator Contact socket Collet Housing Back nut Collet Nut ODU Plug Back nut Collet nut Collet Inner housing Insulator Locking fingers Outer housing Contact pin Touch protection ODU Receptacle Contact socket Housing Hex nut Insulator Page 9
10 Product description Everything from one source ODU the system supplier Every connection also needs its cable. Make no compromises here when it comes to the quality of the complete connection system. ODU gives you the complete system solution from one source, with no intermediary suppliers. Cable assembly is a very complex subject. It requires equal measures of expertise in the areas of connectors, cables and assembly. ODU meets all these requirements in full. Benefits for the customer: ODU handles the complete processing, from procuring the cable to procuring connectors from other companies, and assembly up to individual extrusion or potting No one knows our products better then we no one knows how our products have to be processed better then we do Close cooperation and experience with well-known cable manufacturers Assembly of all standard lines, as well as special lines such as hybrid cable Assembly of overmolded cable crossovers 100 % inspection systems can be used at the customer without testing. Various potting options for water-tight or vacuumtight system UL approval (File: E333666) for cable assembly Production in cleanroom acc. EN ISO possible Production acc. medical certification ISO : AC : 2007 possible State-of-the-art production facilities in Mühldorf (Germany), Shanghai (China), Camarillo (USA) and Sibiu (Romania). Page 10
11 Product description The part number key P A No. Description Coding 1 Type S = Plug G = Receptacle K = In-line receptacle 2 Style 1 9 and A Z 3 Size 1, 2, 3 4 SPC P 5 Coding 6 Housing material / colour 8 Insulator material 9 Colour coding* 10 Surface 11 Termination 12 Type A Termination cross section (2 positions) Collet system (2 positions) Cable bend relief (2 positions) * Size 1 3: Colour Coding with cable bend relief Example S 1 1 P 2 G U 0 A C A K = Plug 2 = Style 1, IP 50 with standard back nut 3 = Size 1 4 = Product series SPC 5 = Coding 2 6 = Plastic housing in grey 8 = Insulator material PSU/PPSU 9 = No colour coding 10 = Surface Ag 11 = Crimp termination 12 = Plastic housing without EMI protection 13/14 = Cross section 4.0 mm² 16/17 = Collet system for cable diameter > mm 18/19 = Without cable bend relief Page 11
12 For your notes Page 12
13 ODU SPC with push-pull locking Page 13
14 Without protection class Available housing sizes Outside diameter Plug Size 1 Size 2 Size Dimensions in mm Technical data Mechanical and electrical data Size / Contact diameter Mechanical data: mm mm mm Insertion force 10 N 13 N 16 N Withdrawal force 9 N 12 N 15 N Draw out strength1 > 75 N > 80 N > 85 N Electrical data: Nominal current 2 32 A 42 A 53A Max. continuous current 2 55 A 70 A 91 A Surge current (period 10 ms) 5 ka 8 ka 12 ka Rated voltage (= nominal voltage) 3 1,000 V 1,000 V 1,000 V Test voltage 4,260 V 4,260V 4,260 V Contact resistance 350 µω 300 µω 250 µω 1 Connector can be used again after a accidentally demating. The datas are for the standard housing without insert. 2 Derating measurement procedure see page 42 / 43. Data derived from the derating curve. 3 Tested with standing voltage with 50 Hz acc. DIN EN (VDE 0627) : / EN : Page 14
15 ODU SPC with push-pull locking protection class IP 50 and IP 67 * *Explanation of protection classes see page 47. Page 15
16 Protection class IP 50 and IP 67 Straight plug Type P 0 A Size P 0 A Connector type Style Type of back nut Size Dimensions in mm L1 L2 D SW-A SW-B S 1 IP 50 with standard back nut 0 0 S 2 IP 50 with back nut for cable bend relief 0 S S 3 IP 67 with standard back nut ~ 46 ~ ~ 52 ~ ~ 60 ~ S 4 IP 67 with back nut for cable bend relief 0 S SW-B L1 SW-B L1 D D Cable bend relief must be ordered separately. See page 30. Explanation of protection classes see page 47. Style 1 and 3 Style 2 and 4 SW-A L2 SW-A L2 Page 16
17 Protection class IP 50 and IP 67 Receptacle Type P 0 A Size P 0 A Connector type Style Size Dimensions in mm L D C M2 M3 SW Panel cut-out G 1 IP 50 for installation from front of panel G 5 IP 50 see page 18 G E IP 67 see page M SW 12.6 / M SW 15.6 / 16.6 Cable bend relief must be ordered separately. See page 30. Explanation of protection classes see page 47. L C SW D M M SW 19.1 / 21.1 Style 1 Technical data IP 50 in reference to the tightness of the end device Anti-rotation feature Minimum wall-thickness 1 mm Touch proof. M2 Page 17
18 Protection class IP 50 and IP 67 Receptacle Type P 0 A Size P 0 A Connector type Style Size Dimensions in mm L D M1 M2 M3 SW Panel cut-out G 1 IP 50 see page M SW 12.6 / 13.6 G 5 IP 50 with continuous thread, installation from rear or front of panel, optimal distance adjustment M SW 15.6 / 16.6 G E IP 67 see page M SW 19.1 / 21.1 Cable bend relief must be ordered separately. See page 30. Explanation of protection classes see page 47. L M1 SW M3 D Style 5 Technical data IP 50 in reference to the tightness of the end device Anti-rotation feature Minimum wall-thickness 1 mm Touch proof. M2 SW Page 18
19 Protection class IP 50 and IP 67 Receptacle Type P 0 A 0 0 Size P 0 A Connector type Style Size Dimensions in mm L D C M1 M2 M3 SW Panel cut-out G 1 IP 50 see page 17 G 5 IP 50 see page 18 G E IP 67 for installation from front of panel ~6.0 ~ M SW 12.6 / 13.6 Explanation of protection classes see page 47. L M1 SW D M ~6.0 ~ M SW 15.6 / ~6.0 ~ M SW 19.1 / 21.1 Style E Technical data IP 67 in mated condition IP 50 in unmated condition and in reference to the tightness of the end device Anti-rotation feature Minimum wall-thickness 1 mm Touch proof. M2 Page 19
20 Protection class IP 50 and IP 67 In-line receptacle Type P S 0 A Size P S 0 A Connector type Style Type of back nut Size Dimensions in mm L D SW-A SW-B K 1 IP 50 with standard back nut 0 0 K 2 IP 50 with back nut for cable bend relief 0 S K 3 IP 67 see page ~ Cable bend relief must be ordered separately. See page 30. Explanation of protection classes see page 47. Note: Standard colour is black other colours on request! Style 1 Style 2 L1 L1 D D 2 ~ ~ K 4 IP 67 see page 21 0 S SW-A SW-B SW-A SW-B Page 20
21 Protection class IP 50 and IP 67 In-line receptacle Type P S 0 A Size P S 0 A Connector type Style Type of back nut Size Dimensions in mm L1 D SW-A SW-B K 1 IP 50 see page K 2 IP 50 see page 20 0 S K 3 IP 67 with standard back nut ~ ~ Style 3 Style 4 L1 L1 D D 3 ~ K 4 IP 67 with back nut for cable bend relief 0 S Cable bend relief must be ordered separately. See page 30. Explanation of protection classes see page 47. Note: Standard colour is black other colours on request! SW-A SW-B SW-A SW-B Page 21
22 Protection class IP 50 and IP 67 Coding Housing material P 0 A P 0 A Coding Receptacle front view Size Housing material Housing material 1 G Plastic, grey (similar RAL 7035) S Plastic, black (similar RAL 9004) 2 W Plastic, white (similar RAL 9002), on request 9 Insulator material Contact surface P 0 A P 0 A Material insulation body Material Contact surface Contact surface U PSU / PPSU (autoclaveable) A Galv. Ag (standard) B Galv. Au (updated resistance) Explanation of protection classes see page 47 Page 22
23 Protection class IP 50 and IP 67 Termination Cross section P 0 A P 0 A Connector type Cross section Size Termination Plug Receptacle In-line receptacle Cross section mm² AWG Crimp C Standard Standard 4.0 K 0 Solder L L 0 Screw S Standard N 0 Biggest possible cross section is stated. This cross-section depends on the cable diameter under consideration of the collet system. Other cross sections on request! Termination cross-section: The indicated cross-sections correspond to a flexible conductor design in accordance with EN 60228:2005 class 5 or to a flexible conductor design (7/19 strands) in accordance with AWG (ASTM B258-02). Explanation of protection classes see page 47. Page 23
24 Protection class IP 50 and IP 67 Collet system P 0 A Cable diameter Size mm Collet system > > > > > > > > > Collet nut Anti-rotation pin Cable diameter Page 24
25 Special solutions Page 25
26 Special solutions Special solutions ODU as specialist in customized solutions has all main competences under one roof. Development, our own tool shop, stamping, moulding, surface plating, manufacturing of complete assembly machines, cable assembly, etc. With all these possibilities we are able to offer custom tailored solutions for our customers. When do we actively pursue custom specific solutions? Are development effort, tool making and production costs in an acceptably proportion to lot size and unit price? Our know-how makes it possible to give you fast and competent information. Here are some examples how a special solution may look: ODU SPC with metal housing and bayonet-locking Robust zinc-die-casting housing Effective power 300 A / 1,000 V Easy mating and demating because of bayonet-locking High resistance against chemical and environmental influences. ODU SPC with plastic housing and snap-in locking Economical plastic housing Effective power 50 A / 400 V Easy to assembly Housing available in custom colour. ODU SPC High Current with bayonet-locking Robust plastic housing Effective power 550 A / 1,000 V Bayonet- and optional secondary locking Colour coding acc. to DIN possible Optional: Termination technology for alu cable. Page 26
27 Special solutions ODU SPC series 329 Current up to 400 A Voltage up to 380 V Robust housing Bajonett locking. ODU SPC with EMI Protection With metalized inner housing. Metalized inner housing Page 27
28 For your notes Page 28
29 Accessories, Tools and termination technology Assembly Instructions Page 29
30 Accessories Silicone cable bend relief Because of different raw materials the colours may slightly different from RAL numbers. Temperature range: Silicone: 50 C bis +200 C, Short-term up to +230 C Autoclaveable Size Part number Dim. L Cable outer dimension mm Min. mm Max. mm > > > > > > > > > > > > > > > > > > > > Colour code Colour RAL-Nr. similar 202 Red White Yellow Green Blue Grey Black 9005 Page 30
31 Accessories Protective covers Fasten with loop style 1 Fasten with solder lug style 2 Protection class IP 50 Protection class IP 67 with receptacle style E Protection class IP 50 Protection class IP 67 with receptacle style E Part number Dimensions in mm Part number Dimensions in mm Size A B C D B E Size A B C D B 1 K K K Please register desired colour of cover and lanyard material. Code Material lanyard Colour 003 Polyamid White 008 Polyamid Black 103 Stainless steel White 108 Stainless steel Black 1 K K K Please register desired colour of cover and lanyard material. A B C A B C B B Code Material lanyard Colour 203 Polyamid White 208 Polyamid Black 303 Stainless steel White 308 Stainless steel Black Style 1 Style 2 E D 3.2 D Page 31
32 Accessories Termination set for screw termination For receptacle style G1, G5 and GE Installation Thread Part number M M M Loop termination Hex nut Locking washer Flat washer Ring lug Flat washer Torques Connection thread Torque Max. in Nm M2 0.2 M3 0.5 M4 1.2 M5 2.0 M6 3.0 M8 6.0 M M M M M M Max. torque for solid threaded stud and brass contact material Thread termination Page 32
33 Tools and terminations technologies Page 33
34 Tools and terminations Termination technologies The three following termination technologies are possible for the ODU single contacts: Soldering Screwing Crimping Solder termination Soldering uses a melted added metal (solder), whose melting temperature is less than that of the base metals to be connected, in order to connect two metallic materials. In contrast to crimping, the wire to be soldered can also be considerably smaller than the intended solder hole. Please note: avoid undue temperature increases in sockets. Screw termination This method of terminating cables is usually done using cable lugs with serrated washers, flat washers and nuts. Washers and nuts are included in the delivery as standard (you will find corresponding assembly sets on page 32). Crimp termination The processing of contacts by crimping in order to produce connection lines results in a permanent, corrosionfree and securely contacted connection. Even those who are not experts can produce this time-saving termination. The cold pressing operation (crimping) compresses the conductor and contact material at the pressing points to the extent that a gas-tight connection results that is tight with respect to the conductor material. Crimping is possible on the smallest cross-sections as well as on large ones. The 8-point crimpers are advantageously chosen for smaller cross-sections ( mm²) while hexagonal crimpers are chosen for the larger cross-sections. The crimping s width across corners is no larger than the original diameter. This process does not damage the line s insulation, which can be run up to the contact end. For flawless crimping, it is absolutely essential that the bore diameter be matched exactly to the cable. Flawless crimping of our contacts can only be guaranteed when the crimping tools recommended by ODU are used. In order to advise you, we will need to know your cable type and the cable cross-section a sample with datasheet is particularly helpful. Cross-section of a hexagonal crimping. Page 34
35 Tools and terminations Tools The crimping tools and the associated crimping inserts are designed for the forces necessary for the pressing operation, and are provided with a safeguard to prevent the crimper from opening prematurely. Opening is only possible after the pressing has been completed with the necessary pressure. Hexagonal crimping tool for cross-sections 4.0 mm² and 6.0 mm². Order no Hydraulic hexagonal crimping tool for cross-section 10.0 mm². Crimp tong: Order no Crimp insert: Order no Page 35
36 Tools and terminations Spanner wrench L B b SW t = Thickness Part number Dimensions in mm SW t B L b Page 36
37 Assembly instructions Page 37
38 Assembly instructions Assembly instructions Assembly of version with protection class IP 50 and IP 67 Clamping nut Collet Sleeve Contact Insulator Connector housing 1. Slide the clamping nut, collet and sleeve on to the stripped cable. 2. Crimp or solder the wire to the contact. 3. Slide the insulator on to the contact. 4. First slide the sleeve up to the contact. 5. Slide the sleeve and collet into the connector housing (observe the position of the guide in the connector housing) Screw the clamping nut on to the assembled con nector, hold it against the surface (1) and use the ODU openend wrench (see page 36) to tighten it. If necessary, secure the screw thread with adhesive. Recommended adhesive: Scotchweld, ODU order no Recommended cleaning agent: Isopropyl alcohol If adhesives that have not been released are used, cracks may appear after some time. Use only the specified adhesive. Page 38
39 Assembly instructions Stripping lengths for solder and crimp termination The following table is intended to simplify the assembly. It contains guideline figures for preparing the cable as far as the cable stripping lengths are concerned. A Cable sheath Size A Single wire Tightening torques for the back nuts Size Tightening torque 0.5 Nm 0.5 Nm 0.7 Nm 1 Nm = 8.85 inch-pounds Page 39
40 For your notes Page 40
41 Technical Information Page 41
42 Technical information Basic principles of current carrying capacity Derating measurement procedure (DIN EN :2002) Structure of the basis current carrying capacity curve Current in A l3 t3 Upper limit temperature determined by the materials t2 l2 t1 l1 t3 t2 t1 Ambient temperature t in C A connector s current carrying capacity is determined by measurement. The self-heating and ambient temperature are taken into account when determining the current carrying capacity, which is limited by the thermal properties of the contact materials used; the upper limit temperature of these materials should not be exceeded. The relationship between current, the temperature increase caused as a result of the power dissipation at the contact resistor, and the ambient temperature is depicted in a curve. The curve is drawn in a linear coordinate system with the current I as the ordinate and the temperature t as the abscissa. The upper limit temperature is shown as a vertical straight line. The corrected current carrying capacity curve (derating curve) can be derived from the basis curve. To accomplish this, the measured curve is reduced by the derating factor 0.8 in order to eliminate variances, measurement errors, or the like in the test results. In three measurements, the self-heating (Δt) is determined at different currents on at least three connectors and the points determined in this process are connected to form a parabolic basis curve. Page 42
43 Technical information Current carrying capacity diagram Capacity of the connection* Current carry capacity in ampere (derating curve) Size 3 Size 2 Size Ambient temperature C *Tested with the stipulated termination cross-section (see page 23). Page 43
44 Technical information Housing materials /surfaces Material insulator ( listed) Component part Material Surface Attribute Norm Unit PSU Housing PEI Housing (shielded) PEI chem. Ni Back nut PEI Collet nut PA / PSU / PEI Cover PEI Nut receptacle Cu-alloy Ni Contacts Cu-alloy Ag or Au Contact element CuBe-alloy Ag or Au Dialectric strenght DIN ASTM D-149 kv / mm 42 Operating temperature C 40 /+160 Flammability rating UL-94 V-0 Creeping distance according to CTI IEC V 175 Page 44
45 Technical information Information for the correct handling Failure mating force of the housing according IEC Size 1 Size 2 Size 3 Not to be inserted when under load (live) acc. to VDE 0627 (DIN EN 61984) Failure mating force > 40 N > 40 N > 50 N Page 45
46 Technical information Sterilizability Autoclave The connectors in the ODU SPC series have been tested for 200 autoclave cycles according to the sterilization curve below. The standard version of ODU SPC is autoclaveable. Gamma Radiation 4 cycles à 25 k Gray E-Beam 4 cycles à 25 k Gray For additional sterilization methods, please contact our technical team Pressure in mbar absolut Time 0 1. Pre-vacuum Preassure increase Preassure decrease 2. Pre-vacuum Preassure increase Temperature increase in transition Influence 5 min. at 134 C 15 min. at 121 C Preassure decrease After-vacuum Drying time Ventilation Ventilation Increase of pressure Sterilization Drying Sterilization curve Page 46
47 Technical information International Protecting (IP) Classes DIN EN (respectively IEC 529 / VDE 0470 T1) The housing and the locking system of the ODU SPC protect the contacts against outside mechanical influence, such as impact shocks, impurities, dust, unintended contact and penetration of moisture, waster or other liquids (coolants, oils, etc.) Protection classification is indicated with the letters IP and two numbers. To achieve leak tightness at the cable gland, the sealing system must be adapted to the cable and the cable must be smooth, cylindrical and grooveless. Code letters (international protection) First index figure (foreign bodies protection) IP 6 8 Second index figure (water protection) Index Degree of protection Index Degree of protection 0 1 No protection against accidental contact, no protection against intrusion of solid foreign bodies 0 Protection against contact with any large area by hand and against large solid foreign bodies with > 50 mm 1 No protection against water Protection against vertical water drips If coordination to the cable is not possible, the cable area can also be potted. 2 Protection against contact with the fingers, protection against large solid foreign bodies with > 12 mm 2 Protection against water drips (up to a 15 angle) 3 Protection against tools, wires or similar objects with > 2.5 mm. Protection against small foreign solid bodies with 0 > 2.5 mm 3 Protection against diagonal water drips (up to a 60 angle) 4 As 3 however > 1 mm 4 Protection against splashed water from all directions 5 6 Full protection against contact. Protection against interior detrimental dust deposition 5 Total protection against contact. Protection against intrusion of dust Protection against water spray from all directions Protection against temporary flooding Protection against temporary immersion Protection against water pressure In accordance with DIN VDE 0470, DIN EN , IEC 529 Source: ZVEI = German Association of the Electrotechnical and Electronic Industry e.v. Page 47
48 Technical information Conversions AWG cross section (AWG = American Wire Gauge) The AWG system describes the cross section of a wire using a gauge number for every 26 % increase in conductor cross section. With larger wire diameters, the AWG gauge numbers decrease; as the wire sizes increase, the AWG gauge numbers decrease. This is only valid for solid conductors. Most wires are made with stranded conductors. Compared to solid conductors stranded wires offer higher durability, higher flexibility and better performance under bending and vibration. Stranded wires are made from wires with smaller gauge sizes (higher AWG gauge number). The AWG gauge number of the stranded wire is equal to that of a solid conductor of the same size wire. The cross section of the stranded conductor is the sum of cross sections of the single conductors. For example, a AWG-20 stranded wire of 7 AWG-28 conductors has a cross section of mm²; an AWG-20 stranded wire with 19 AWG-32 conductors has a cross section of mm². Conversion table AWG/mm² Circular wire AWG Diameter Cross section Weight Max. resistance Inch mm mm² kg/km Ω/km 10 (1) (37/26) (1) (19/25) (37/28) (1) (19/27) (37/30) (1) (19/29) (1) (19/30) (1) (7/28) (19/32) (1) (7/30) (19/34) (1) (7/32) (19/36) (1) (7/34) (19/38) (1) (7/36) (19/40) (1) (7/38) (19/42) (1) (7/40) (19/44) (1) (7/42) , (1) , (7/44) , (1) , (1) , (1) , (1) , Page 48
49 Technical information Technical information / definition / terms Autoclavability See page 46. AWG See page 48. Basis curve Metrologically established current carrying capacity curve for connectors according to the measurement procedure described in EN :2002 depending on the permissible limit temperature of the materials. Clearance distance The shortest distance, measured as a thread measure, between two live metallic parts in the air. Coding System of projections and grooves on mating connectors which prevent otherwise identical connectors from being mated. This is useful when several connectors of the same style are used in the same application. Connector = ODU SPC A component that allows the connection of electrical conductors and that is intended to set up connections with a suitable mating component and/or to separate them. Connectors are operating materials that are not permitted to be inserted or separated when used as intended (when energized). The connector consists of the connector housing and the contact elements. Contact resistance Total resistance from termination to termination; the contact resistance here is considerably lower than the volume resistance. The information provided refers to average values. Creepage distances Shortest distance between live parts on the surface of insulators. All elevations and depressions in the insulator are taken into account as far as the specified minimum dimensions are given. Crimp area The part of a crimp barrel at which the crimp connection is achieved by pressure deformation or by reshaping the barrel around the conductor. Crimp barrel A hollow part of a contact which accepts one or more conductors and which may be crimped through the application of a crimping tool. Crimp connection See page 34. Current carrying capacity (nominal current and max. continuous current) The information refers to sufficiently dimensioned connection cables in accordance with DIN VDE 0295 (EN 60228) in Class 5, so that this is not the source of a greater temperature increase. The specified temperature increase takes place through the contact. The information provided refers to average values. Derating curve The corrected current carrying capacity curve, derived from the established basis curve (0.8 measured current). It takes into consideration production spreads as well as uncertainties in the temperature measurement and the measurement setup. Derating measurement procedure (EN ) Measurement procedure for determining the current carrying capacity of connectors, taking the maximum permissible limit temperature into consideration. Fixed connector A connector for attachment to a rigid surface (panel). Free connector A connector for attachment to the free end of a wire or cable. Also called free hanging connector or in-line receptacle. Impulse current One-time power pulse current with a load period of 10 ms. Insertion or withdrawal force Force that, without the influence of a coupling or locking device, is required for completely inserting or withdrawing pluggable components. Insulator Non-conductive part of a connector, for electrically and mechanically separating live parts and for protection against accidental touching. Lower limit temperature The lowest permissible temperature for operating a connector or plug-in device. For ODU SPC 40 C. Lubrication The contacts are pre-lubricated at the factory. Materials See page 44. Page 49
50 Technical information Technical information / definition / terms Mating cycles Mechanical operation of connectors and plug-in devices by insertion and withdrawal. One mating cycles comprises one insertion and one withdrawal Max. continuous current The metrologically determined current intensity at room temperature (approx. 20 C [70 F]) that causes the contact temperature to rise to the limit temperature. Nominal single contact current load Current load that can load every single contact Nominal voltage Nominal voltage characterizes a component. Operating temperature ODU SPC 40 C to +140 C ( 40 F to 285 F) Operating voltage Is the nominal voltage of the current source intended for use with the connector. The operating voltage is not permitted to exceed the connector s nominal voltage. Plug appliance coupler Operating materials that are permitted to be inserted or separated during the intended use (when energized or electrically charged). Rated current (IEC 61984) The metrologically determined current intensity that leads to an increase of 45 Kelvin in the contact temperature. The current is determined according to the derating measurement procedure (EN :2002) and is derived from the basis curve. Rated voltage Voltage used when rating the connectors and when defining certain operating characteristics. Reference voltage The standardized voltage (VDE 0110 or EN ) for which the insulation of a connector is rated. Solder connection Termination technology in which a melted added metal (solder), whose melting temperature is less than that of the base materials to be connected, is used to join two metallic materials. Termination cross-section The indicated cross-sections correspond to a flexible conductor design in accordance with EN 60228:2005 class 5 or to a flexible conductor design (7/19 strands) in accordance with AWG (ASTM B258-02). Termination techniques Methods for connecting a wire to an electro-mechanical component, e.g., solderless connection according to EN 60352, such as crimp, press-in, etc., or solder contacts. Test voltage The voltage that a connector withstands without flashover or arcing under specified conditions. Upper limit temperature Highest permissible temperature for operating a connector or plug-in device. This temperature includes the selfheating and the ambient temperature. For ODU SPC 140 C (285 F). Watertightness (EN 60529) see page 47. Wire Wires may be provided with an insulation cover (electrical shielding). Cables or conductors may consist of one or more wires. Care must be taken to assure that no person can come in contact with live conductors during installation or operation of the connectors. ODU reserves the right to change the design and performance of any product to meet changing technical developments without prior notice. ODU reserves the right to discontinue any part in this catalog without prior notice and without obligation to continue production after the change. Page 50
51 Technical information Quality management ODU has had a powerful quality management system in place for years. ODU has been successfully certified to ISO 9001 since In addition, the automotive sector of the company group is certified to ISO TS The certification process was carried out by the internationally active BVQI (Bureau Veritas Quality International) company. ODU is also certified according the medical norm ISO : AC : Additional to this ODU ist approved to different certifications: VDE, UL, UL wiring harness, SCA, VG und MIL. Page 51
52 The Complete complete ODU product Product range Range Single contacts (round or flat) High current connectors Circular connectors with Push-Pull locking Modular rectangular connectors PCB connectors Robust connectors Disposable Systems Application specific solutions AMC Advanced Military Connector Cable assembly Page 52
53 Your Partner in Many Application Areas ODU stands for quality, flexibility and reliability. This is why customers working in many application areas rely on ODU products in markets such as the following: Medical Industrial Measuring and testing Military and security Energy Automotive. Page 53
54 For your notes Page 54
55 TELEFAX-INQUIRY: +49/08631/ ODU GmbH & Co. KG Sales ODU SPC Pregelstraße Mühldorf a. Inn GERMANY Company: Name: Department: Street: City: Telephone: Date: ODU SPC Summery of technical requirements. 1. Connector application 2. Environment 3. Connector type Plug Receptacle In-Line Receptacle 4. Special version 5. Style 6. Size Coding Colour Grey Black White (on request) 9. Termination Solder Crimp Screw 10. Cross section mm² AWG 11. Cable diameter mm 12. Cable bend relief (colour) 13. Protection class acc. DIN EN IP 50 (Standard) IP 67 (watertight) Other: 14. Operating temperature C max C min 15. Electrical specifications: - Operating voltage V AC V DC - Operating current Constant: A Short-term: A/ Seconds 16. Chemical resistance against 17. Other requirements 18. Autoclaveable Yes No 19. Required quantity 20. Production quantity Page 55
56 The part number key Nr. Description Codierung 1 Type S = Plug G = Receptacle K = In-line receptacle 2 Style 1 9 and A Z 3 Size 1, 2, 3 4 SPC P 5 Coding 6 Contact type / surface 8 Insulator material 9 Colour coding* 10 Surface 11 Termination 12 Type A Termination cross section (2 positions) Collet system (2 positions) Cable bend relief (2 positions) * Size 1-3: Colour Coding with cable bend relief Example S 1 1 P 2 G U 0 A C A K = Plug 2 = Style 1 IP 50 with standard back nut 3 = Size 1 4 = Product Series SPC 5 = Coding 2 6 = Plastic housing in grey 8 = Insulator material PSU/PPSU 9 = No colour coding 10 = Surface Ag 11 = Crimp termination 12 = Plastic housing without EMI protection 13/14 = Cross section 4,0 mm² 16/17 = Collet system for cable diameter > mm 18/19 = Without cable bend relief Page 56
57 Please open
58 ODU Worldwide ODU GmbH & Co. KG. Pregelstr Mühldorf a. Inn Germany ODU France Phone: [email protected] ODU Scandinavia Phone: [email protected] ODU USA Phone: [email protected] ODU Shanghai Trading Phone: [email protected] Phone: Fax: [email protected] ODU UK Phone: [email protected] Other qualified representatives shown on our website: /sales Stand: 2013/ b-v02-Katalog-SPC_e Design: KOMMA Werbeagentur GmbH
ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal. www.odu.de
Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal Miniature Circular Connectors with Push-Pull Locking for Medical Applications Applications Medical Test and measure equipment
ODU MINI-SNAP PC. Miniature Cylindrical Connectors with Push-Pull-Locking in Plastic
Catalogue No. 1005 PC-d-e ODU MINI-SNAP PC Miniature Cylindrical Connectors with Push-Pull-Locking in Plastic ODU Steckverbindungssysteme GmbH & Co. KG, Pregelstr. 11, 84453 Mühldorf a. Inn, Germany Phone:
ODU MINI-SNAP. Miniature Cylindrical Connectors with Push-Pull-Locking Series F
Catalogue Nr.: 5--a-e ODU MINI-SNAP Miniature Cylindrical Connectors with Push-Pull-Locking Series F ODU Steckverbindungssysteme GmbH & Co. KG, Pregelstraße, D-85 Mühldorf/Inn Telefon: +9/86 /6 56-, Telefax:
ODU System Solutions everything from one source
ODU System Solutions everything from one source www.odu.de A connection you can count on! Every connection also needs its cable. Make no compromises here when it comes to the quality of the complete connection
400 Series Buccaneer BUCCANEER POWER. bulgin
bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when
Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Universal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
Glenair Military and Industrial Power and Signal Connectors
Glenair Military and Industrial Power and Signal Connectors Series ITS (And FRITS) 5015 Type Reverse Bayonet Connectors Derived from MIL-DTL-5015 and VG95234 Mating mechanism (3 reverse bayonets at 120
HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015
HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 Fiber Optic VAR Program Hirose Launches Fiber Optic Cabling VAR Program to provide a complete fiber optic cable assembly and wire harness solutions to
picomax The Pluggable Connection System
picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
HARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials
VDE Information General Information The voltage which can be applied to a terminal depends on the relevant regulations, the installation conditions and, of course, the dimensions and insulating materials
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
PowerLine. Single Pole Connectors
PowerLine Single Pole Connectors Ten 47 Limited Unit 2B Frances Industrial Park Kirkcaldy, Scotland, UK KY1 2XZ Tel: +44 (0)1592 655725 Fax: +44 (0)1592 651049 Email: [email protected] INTRODUCTION BACKGROUND
Trapezoidal-Connectors Series TMC
Trapezoidal-Connectors Series TMC Subminiature-D Connectors to DIN 41 652/IEC 807-3 General Series TMC connectors are available in 5 different housing sizes with 9, 15, 25, 37 and 50 pins. In applications
Industrial circular connectors
Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors
Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4
This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable
SMA Connectors. RF Coax Connectors. Product Facts
SMA Connectors Product Facts Performance to 12.4 GHz and beyond Available in various base metal options, including stainless steel, brass and zinc diecast Uses industry standard crimp tools and processes
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.: 1804920
Extract from the online catalog PC 4/ 4-ST-7,62 Order No.: 1804920 The figure shows a 5-pos. version of the product Plug component, nominal current:, rated voltage: 400 V, pitch: 7.62 mm, no. of positions:
SMA Interface Mating Dimensions (Per MIL-STD-348)
SMA Series SMA 6 SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Interface Dimensions MALE Inches/Millimeters 3 Minimum Nominal Maximum LTR in. mm in. mm in. mm A.250 6.35.263 6.68.. B.1790 4.55.1808
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
IEC Connectors. Introduction
Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings
5.2. Overview. The better method to install solderless compression connectors on power cable
5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Specification of 5 Wire Analog Touch Panel
Specification of 5 Wire Analog Touch Panel 5 WIRE ANALOG RESISTIVE TOUCH PANEL A. Application This specification applies to the 5 Wire Analog Resistive Touch Panel. B. Environmental Conditions 1. Operating
ISO VIEW OF AX SERIES XLR CABLE CONNECTOR
ISO VIEW OF AX SERIES XLR CABLE CONNECTOR One piece ground / latch spring design incorporating twin wipe contacts for a direct connection path from mating shell to ground providing enhanced connection
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
Assembly Instruction CAI- Connector with universal Endbell
CANNON STANDARD Seite 1 von 17 CAI- Connector with universal Endbell Shell size 10 to 36 with APK contact / Trident T2P - contact Illustration and assembly exemplary of CAI Layout 20-0306 with APK / Trident
PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
CABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
Waterproof Connectors for Outdoor Use
Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight
PAM Connectors. PAM Bayonet Connectors
PAM Bayonet Tel : 33 (0)1 60 84 21 40 Fax : 33 (0)1 60 84 43 81 [email protected] www.bernier.tm.fr Overview Miniature audio connectors with bayonet locking system, equipped with 07 or 10 contacts, and
Now Available in Black Zinc Nickel
847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances
SOURIAU s discrete wire sealing
SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing
Fakra. Coaxial connectors. DC 6 GHz
C-Blue D-Bordeaux GPS application GSM/Mobil Phone The FAKRA (Automobile Expert Group) has therefore defined a standardised connector system for the various communication applications in cars. Our FAKRA-compliant
Product Information. HMC 6 Hybrid Motor Cable
Product Information HMC 6 Hybrid Motor Cable November 2014 HMC 6 Single-cable solution for servo drives Motors normally need two separate cables: One cable for the motor encoder One cable for the motor
6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
Feed-through terminal block - SSK 110 KER-EX - 0502058
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
HARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
A good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
HARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
FASTON Terminals and Connectors
Introduction Product Facts Straight, right-angle and receptacle-tab combinations available Receptacles available for 6.3 mm, 4.8 mm and 2.8 mm tab size (.250,.187 and.110 Series) Receptacles mate with
AMP Standard Terminals and Splices. RoHS. Ready
AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
ASSEMBLY INSTRUCTIONS Residential Roof solutions
ASSEMBLY INSTRUCTIONS Residential Roof solutions CROSSRAIL System USA Table of contents TABLE OF CONTENTS THE COMPANY SAFETY REGULATIONS MATERIALS REQUIRED TOOLS REQUIRED ASSEMBLY TERMS AND CONDITIONS
Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?
Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059? Speaker: Wolfgang Sichmann, Product Manager PCB Plug-In Connectors,
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
gesis IP + Heavy Duty Class I, Zone 2
gesis IP + Heavy Duty gesis IP+ 20i HD Z2 Heavy-Duty Connectors for Class 1, Zone 2 Hazardous Locations Catalog 2012 Catch the Next Wave in Modular Connections Plug & Go Heavy-Duty Connectors for areas
High-ohmic/high-voltage resistors
FEATURES These resistors meet the safety requirements of: UL1676 (range 510 kω to 11 MΩ) EN60065 BS60065 (U.K.) NFC 92-130 (France) VDE 0860 (Germany) High pulse loading capability Small size. APPLICATIONS
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist...
TABLE OF CONTENTS Custom Molded Cable Assemblies and Connectors..........................2 Capabilities.....................................................................3 Standard Connector Products.......................................................4
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes
BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
RJF TV Ethernet connection system for harsh environment
RJF TV Ethernet connection system for harsh environment ROHS compliant N & BZ RJFTV allows you to use an Ethernet Class D / Cat. 5e connection for 10 BaseT, 100 BaseTx or 1000 BaseT networks in harsh environments.
FullAXS CONNECTOR SEALING & CABLE ASSEMBLY
FullAXS CONNECTOR SEALING & CABLE ASSEMBLY System Solution Guide Next Generation x-tta Solution Next generation WiMAX and Long Term Evolution (LTE) Fiber/Power/Signal To The Antenna (x-tta) connectivity
GISMA UNDERWATER CONNECTORS SERIES 40
CONTENTS SEITE / PAGE GENERAL 4 GENERAL ARRANGEMENT 5 DESIGN MECHANICAL FEATURES 7 FIBRE OPTIC FEATURS 7 ELECTRICAL FEATURES 7 REFERENCE SYSTEM 8 REFERENCE SYSTEM CONTACTS 9 CONTACT LAYOUTS 9 SUGGESTIONS
1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide
1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible
ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
UTS discrete wire sealing
Technical characteristics Mechanical Durability: 250 matings & unmatings Vibration resistance: Sinusoidal vibrations per CEI 605-4 - from 10 to 2000 Hz Thermal shock: 5 cycles 30 min. from -40 C to 105
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
Anderson Power Products
Anderson Power Products Anderson Power Products APP s philosophy is to provide products and services within the trading markets of our customers. We currently serve our world-wide customer base from customer
PC 4/ 5-STF-7,62. Extract from the online catalog. Order No.: 1828278
Extract from the online catalog PC 4/ 5-STF-7,62 Order No.: 1828278 The figure shows a 5-pos. version of the product Plug component, Nominal current: 20 A, Nom. voltage: 400 V, Pitch: 7.62 mm, Number of
NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE
B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY
A&C Solutions: please contact us.
FOR LIGHTING ABOUT SOLUTIONS DESIGNED AROUND YOUR BUSINESS A&C Solutions is a connector & harness distribution specialist that offers a tailor made solution to any application and delivers high quality
