1 Table of Contents Bare Copper Solid ed Single Conductors XHHW-2 SIS USE-2/RHH/RHW-2 Jacketed Singles Photovoltaic Wire THW and THW-2 Weatherproof Line Wire Cathodic Protection Transformer Riser Wire Twisted Cables ServicePlex Copper Service Drop 400 Hz Cable Preassembled Aerial Tray and Power Cable SER/SEU Tray Cable Shielded Tray Cable ASD/VFD ServiceDrive System Cable Connectors Termination Kits Armor Feeder MC Cable and Connectors Jacketed MC Cable and Connectors EnviroPlus Armor (LSZH) ServiceTeck (Teck90) Cable and Connectors 2KV MC Medium Voltage MC Pump and Irrigation Contact Wire Messenger for Aerial Color Codes Minimum Bending Radii Maximum Pull Tensions Sheave Selection Chart Cable Installation Tips Conversion Factors Terms and Conditions Table of Contents Sing Tr

2 Bare Copper Manufacturing quality. Delivering service. Bare Copper Solid Conductor Bare or Tinned, Soft (Annealed), Medium Hard, Hard Drawn Applications: For use in electrical grounding systems, and on insulators for overhead transmission and distribution applications. ASTM B-1 (Hard Drawn) ASTM B-2 (Medium Hard Drawn) ASTM B-3 (Soft or Annealed) ASTM B-33 (Tinned Soft or Annealed) REA/RUS Approved Federal standard QQ-W-343 Part or MCM Nominal Dia. Net Weight per 1000ft. (lbs.) Hard Drawn Medium Hard Drawn Soft (Annealed) DC Min. Breaking DC Resistance Min. Breaking Resistance Strength (Ohms/1000ft.) Strength (Ohms/ C (lbs.) 20 C DC Resistance (Ohms/ C Bare Tinned BSOS BSOS BSOS SOLID BARE COPPER BSOS BSOS BSOS BSOS , BSOS , BSOS , BSOS , BSOS1/0 1/ , BSOS2/0 2/ , BSOS3/0 3/ , BSOS4/0 4/ , * Per NEC Table Based on conductor temperature of 80 C; ambient temperature of 40 C; 2 ft./sec. wind. 2

3 Bare Copper ed Conductor Bare or Tinned, Soft (Annealed), Medium Hard, Hard Drawn Bare Copper Applications: For use in electrical grounding systems and on insulators for overhead transmission and distribution applications. ed conductors offer greater flexibility than solid. ASTM B-1 (Hard Drawn) ASTM B-2 (Medium Hard Drawn) ASTM B-3 (Soft or Annealed) ASTM B-8 (Concentric Lay ed) ASTM B-33 (Tinned Soft or Annealed) ASTM B-787 (Combination strand) REA/RUS Approved Federal standard QQ-W-343 Part or MCM ing Class Nominal Net Weight per 1000ft. (lbs.) Hard Drawn Medium Hard Drawn Soft Drawn Min. DC Min. Breaking DC Resistance Breaking Resistance Strength (Ohms/1000ft.) Strength (Ohms/ C (lbs.) 20 C DC Resistance (Ohms/ C Bare Tinned BST26S K BST7S B BST7S B BST7S B BST7S8 8 7 B BST7S6 6 7 B , STRANDED BARE COPPER BST7S4 4 7 A,B , , BST7S3 3 7 A,B , , BST3S2 2 3 AA , , BST7S2 2 7 A,B , , BST7S1 1 7 A,AA , , BST19S B** , , BST7S1/0 1/0 7 A,AA , , BST19S1/0 1/0 19 B** , , BST7S2/0 2/0 7 A,AA , , BST19S2/0 2/0 19 B** , , BST7S3/0 3/0 7 A,AA , , BST19S3/0 3/0 19 B** , , BST7S4/0 4/0 7 A,AA , , BST19S4/0 4/0 19 B** , , BST61S4/0 4/0 61 D , , *Per NEC Table Based on conductor temperature of 80 C; ambient temperature of 40 C; 2 ft./sec. wind. ** Ref ASTM B-787 NOTE: The data shown is approximate and subject to standard industry tolerance 3

4 Bare Copper Manufacturing quality. Delivering service. Bare Copper ed Conductor Bare or Tinned, Soft (Annealed), Medium Hard, Hard Drawn Applications: For use in electrical grounding systems and on insulators for overhead transmission and distribution applications. ed conductors offer greater flexibility than solid. ASTM B-1 (Hard Drawn) ASTM B-2 (Medium Hard Drawn) ASTM B-3 (Soft or Annealed) ASTM B-8 (Concentric Lay ed) ASTM B-33 (Tinned Soft or Annealed) REA/RUS Approved Federal standard QQ-W-343 Part or MCM ing Class Nominal Net Weight per 1000ft. (lbs.) Hard Drawn Medium Hard Drawn Soft Drawn Min. DC Min. Breaking DC Resistance Breaking Resistance Strength (Ohms/1000ft.) Strength (Ohms/ C (lbs.) 20 C DC Resistance (Ohms/ C Bare Tinned BST19S A , , BST37S B , , BST19S A , , STRANDED BARE COPPER BST37S B , , BST19S A.678 1, , , BST37S B.681 1, , , BST19S A,AA.726 1, , , BST37S B.728 1, , , BST19S AA.811 1, , , BST37S A,B.813 1, , , BST61S B.891 1, , , BST37S AA.997 2, , , ,000 BST61S A,B.998 2, , , ,000 BST37S AA , , , ,193 BST61S A,B , , , ,193 * Per NEC Table Based on conductor temperature of 80 C; ambient temperature of 40 C; 2 ft./sec. wind. 4

5 Single copper conductor, stranded, insulated with moisture, heat, and flame resistant, chemically cross-linked polyethylene insulation. Temperature rating 90 C in wet and dry locations. Available in colors. Applications: Type XHHW-2, CT is suitable for general purpose wiring, for power distribution and branch circuit wiring where a cable having superior flame retardance is required. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). XHHW-2 CT Rated ASTM B3, B8 and B787 UL 44, ICEA S /NEMA WC-70 Federal spec A-A-59544, 90 C Wet/Dry For CT use 1/0 and larger Gasoline and Oil Resistant II C(UL)US RW90: CSA/UL Listed Sunlight Resistant -40 C rated Suitable for use in 105 C Dry System Appliance Wiring Material: Style 3578 Single Conductors Part or MCM Nominal Net Weight per 1000 feet (lbs.) 90 C Wet/Dry XH14BK XH12BK XH10BK XH8BK XH6BK XH4BK XH3BK XLPE,XHHW-2, CT XH2BK XH1BK XH1/0BK 1/ XH2/0BK 2/ XH3/0BK 3/ XH4/0BK 4/ XH250BK XH300BK XH350BK , XH400BK , XH500BK , XH600BK , XH750BK , *Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. 5

6 Single Conductors Single copper conductor, stranded, insulated with moisture, heat, and flame resistant, chemically cross-linked polyethylene insulation. Temperature rating 90 C in wet and dry locations. All sizes pass the vertical flame test (VW-1). Available in colors. Applications: Type XHHW-2, VW-1 is suitable for general purpose wiring, for power distribution and branch circuit wiring where a cable having superior flame retardance is required. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). XHHW-2 VW-1, CT Rated ASTM B3, B8 and B787 UL 44, ICEA S /NEMA WC-70 Federal spec A-A-59544, 90 C Wet/Dry For CT use / IEEE 1202/FT4 1/0 and larger Gasoline and Oil Resistant II C(UL) US RW90:CSA/UL Listed Sunlight Resistant (#14-#8: Black only) -40 C rated Suitable for use in 105 C Dry System Appliance Wiring Material: Style 3578 Part or MCM Nominal Net Weight per 1000 feet (lbs.) 90 C Wet/Dry XHVW14BK XHVW12BK XHVW10BK XHVW8BK XHVW6BK XHVW4BK XLPE, XHHW-2, VW-1 XHVW3BK XHVW2BK XHVW1BK XHVW1/0BK 1/ XHVW2/0BK 2/ XHVW3/0BK 3/ XHVW4/0BK 4/ XHVW250BK XHVW300BK , XHVW350BK , XHVW400BK , XHVW500BK , XHVW600BK , XHVW750BK , *Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote.

7 Single tinned copper conductor, stranded, insulated with moisture, heat, and flame resistant, chemically cross-linked polyethylene insulation. Temperature rating 90 C in wet and dry locations. All sizes pass the vertical flame test (VW-1). Available in colors. Applications: Type XHHW-2, VW-1 is suitable for general purpose wiring, for power distribution and branch circuit wiring, where a cable having superior flame retardance is required. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). XHHW-2 VW-1, Tinned, CT Rated ASTM B3, B8, B33 and B787 UL 44, ICEA S /NEMA WC-70 Federal spec A-A-59544, 90 C Wet/Dry For CT use/ieee1202/ft4 1/0 and larger Gasoline and Oil Resistant II C(UL) US RW90:CSA/UL Listed Sunlight Resistant (#14-#8: Black only) -40 C rated Suitable for use in 105 C Dry System Appliance Wiring Material: Style 3578 Single Conductors Part or MCM Nominal Net Weight per 1000 feet (lbs.) 90 C Wet/Dry XHVWT14BK XHVWT12BK XHVWT10BK XHVWT8BK XHVWT6BK XHVWT4BK XLPE, XHHW-2, VW-1 XHVWT3BK XHVWT2BK XHVWT1BK XHVWT1/0BK 1/ XHVWT2/0BK 2/ XHVWT3/0BK 3/ XHVWT4/0BK 4/ XHVWT250BK XHVWT300BK , XHVWT350BK , XHVWT400BK , XHVWT500BK , XHVWT600BK , XHVWT750BK , *Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. 7

8 Single Conductors Single copper conductor, tinned, stranded, insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation (VW-1). Temperature rating 90 C in wet and dry locations. Switchboard Wire SIS UL 44 C(UL) US: CSA/UL Listed (#14 and Larger) Flame Rated: UL 1581 Vertical Flame (VW1) (#14 and larger) Dual Rated Type XHHW-2 (#14 & larger) (UL 66 Fixture Wire for #16 ) Per ICEA S / NEMA WC-70 Gasoline and Oil Resistant II Sunlight Resistant (Black only) Excellent crush and abrasion resistance -40 C rated Federal Spec AA Suitable for use in 105 C Dry System Flex- Catalog or KCMIL Flex- Stock ing Class B Stock Class C Nominal Net Wt. per 1000 ft. (lbs.) (30ºC Ambient) 90ºC Wet/Dry SIST16 16*** SIST14VW ** SIST12VW ** SIST10VW ** SIST8VW SIST6VW *Per NEC Table ** The overcurrent protection for items marked ** shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. ***#16 is FFH-2. NOTE: Copper Conductor available Non-Tinned. 8

9 Single copper conductor, stranded, insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation. Temperature rating 90 C in wet and dry applications. Available in colors. Application: Types USE-2, RHH/RHW-2 CT are suitable for use in general purpose wiring applications and may be installed in raceway, conduit, direct burial and aerial installations where a cable having superior flame retardance is required. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). USE-2 or RHH/RHW-2 CT Rated ASTM B3, B8 and B787 UL 44 and UL 854, ICEA S /NEMA WC-70 C(UL) US RW90 1kV:CSA/UL Listed C(UL) RPV90 600V Federal spec. A-A For CT use 1/0 and larger Gasoline and Oil Resistant II -40 C rated UL Direct Burial/Sunlight Resistant Suitable for use in 105 C Dry System Single Conductors Part or MCM Net Weight per 1000 feet (lbs.) 90 C Wet/Dry USE14BK USE12BK USE10BK USE8BK USE6BK XLPE USE-2, RHH/RHW-2 CT USE4BK USE3BK USE2BK USE1BK USE1/0BK 1/ USE2/0BK 2/ USE3/0BK 3/ USE4/0BK 4/ USE250BK USE300BK , USE350BK , USE400BK , USE500BK , USE600BK , USE750BK , * Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. 9

10 Single Conductors Single copper conductor, stranded, insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation. Temperature rating 90 C in wet and dry applications. All sizes pass the vertical flame test (VW-1). Available in colors. Application: Types USE-2, RHH/RHW-2 VW-1 are suitable for use in general purpose wiring applications and may be installed in raceway, conduit, direct burial and aerial installations where a cable having superior flame retardance is required. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). USE-2 or RHH/RHW-2 VW-1, CT Rated ASTM B3, B8 and B787 UL 44 and UL 854, ICEA S /NEMA WC-70 Federal spec. A-A For CT use / IEEE 1202/FT4 1/0 and larger Gasoline and Oil Resistant II -40 C rated UL Direct Burial C(UL) US RW90 1kV:CSA/UL Listed C(UL) RPV90 600V Sunlight Resistant (#14-#8: Black only) Suitable for use in 105 C Dry System Part or MCM Net Weight per 1000 feet (lbs.) 90 C Wet/Dry USEVW14BK USEVW12BK USEVW10BK USEVW8BK XLPE USE-2, RHH/RHW-2, VW-1 USEVW6BK USEVW4BK USEVW3BK USEVW2BK USEVW1BK USEVW1/0BK 1/ USEVW2/0BK 2/ USEVW3/0BK 3/ USEVW4/0BK 4/ USEVW250BK USEVW300BK , USEVW350BK , USEVW400BK , USEVW500BK , USEVW600BK , USEVW750BK , * Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote.

11 Single copper conductor, stranded, insulated with moisture and heat resistant cross-linked polyethylene. Temperature rating is 90 C in wet and dry applications. Application: Type RHH, RHW-2 is suitable for wiring in raceways, conduit, etc. Applications include general purpose wiring for power distribution, services, feeders, and branch circuit wiring in residential, industrial, and commercial buildings. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). RHH/RHW-2 CT Rated 2,000 Volt Copper ASTM B3, B8 and B787 UL 44 ICEA S /NEMA WC-70 Federal Spec. A-A For CT use 1/0 and larger Gasoline and Oil Resistant II -40 C rated CSA Direct Burial: 1kV C(UL) US RWU90 1kV:CSA/UL Listed C(UL) RPVU90 1kV Sunlight Resistant Suitable for use in 105 C Dry System Single Conductors Part or MCM Nominal Net Weight (lbs./mft) 90 C Wet/Dry RWU14BK RWU12BK RWU10BK RWU8BK XLPE/ 2KV RHH / RHW-2/RWU90 RWU6BK RWU4BK RWU3BK RWU2BK RWU1BK RWU1/0BK 1/ RWU2/0BK 2/ RWU3/0BK 3/ RWU4/0BK 4/ RWU250BK RWU300BK , RWU350BK , RWU400BK , RWU500BK , RWU600BK , RWU750BK , *Based on ambient temperature of 30 C per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. 11

12 XHHW-2/PVC Single Conductors Single copper conductor, stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation, covered with a sunlight resistant, PVC jacket. Jacket available in colors. Conductors UL 44 UL Listed Construction Per ICEA S / NEMA WC-70 Federal Spec A-A Temperature Rating: 90 C Wet/Dry Sunlight Resistant For CT use 1/0 and larger Part or MCM Jacket Nominal Net Weight (lbs./mft) 30 C Ambient 90 C Wet/Dry XHPVC XHPVC XHPVC XHPVC XHPVC XHPVC XHPVC XHPVC XHPVC1/0 1/ XHPVC2/0 2/ XHPVC3/0 3/ XHPVC4/0 4/ XHPVC XHPVC XHPVC XHPVC *Per NEC-Table The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 12

13 XHHW-2/ServiceCPE Available with tinned conductors. Single copper conductor, stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation, covered with a sunlight resistant, CPE jacket. Conductors UL 44 UL Listed Construction Per ICEA S / NEMA WC-70 Federal Spec A-A Temperature Rating: 90 C Wet/Dry Sunlight Resistant For CT use 1/0 and larger -40 C Rated Single Conductors Part or MCM Jacket Nominal Net Weight (lbs./mft) 30 C Ambient 90 C Wet/Dry XHCPE XHCPE XHCPE XHCPE XHCPE XHCPE XHCPE XHCPE XHCPE1/0 1/ XHCPE2/0 2/ XHCPE3/0 3/ XHCPE4/0 4/ XHCPE XHCPE XHCPE XHCPE *Per NEC-Table The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 13

14 Single Conductors Available with tinned conductors. Single conductor, stranded copper, insulated with heat and moisture resistant, cross-linked polyethylene insulation, (Type XHHW-2), with an overall flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero Lead Jacket. XHHW-2/EnviroPlus Zero Halogen, Limited Smoke Jacket LS and CT Rated 1/0 and larger Conductors UL44 ICEA S /NEMA WC-70 Federal spec A-A UL Listed construction Temperature Rating: 90 C Wet/Dry Sunlight resistant; superior water resistance Excellent crush and abrasion resistance Zero Halogen, Limited Smoke Jacket -40 C Rated Part or MCM Jacket Nominal Net Weight per 1000 feet (lbs.) 30 C Ambient 90 C Wet/Dry XHENV XHENV XHENV XHENV XHENV XHENV XHENV XHENV XHENV1/0 1/ XHENV2/0 2/ XHENV3/0 3/ XHENV4/0 4/ XHENV XHENV , XHENV , XHENV , *Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 14

15 Single copper conductor, stranded, insulated with moisture and heat resistant cross-linked polyethylene. Rated 600V to meet the challenging requirements of transformerless inverters on photovoltaic (solar) panel installations. Temperature rating is 90 C in wet and dry applications. Available in colors. Applications: Photovoltaic wire (600 Volt) for use as interconnection wiring on solar panels in grounded or ungrounded systems as defined in applicable parts of the National Electrical Code (NEC) NFPA 70, such as article (A). Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). Photovoltaic Wire ServiceSolar (for use with Solar Panels) VW-1, USE-2 or RHH or RHW-2 ASTM B3, B8 and B787 UL 44, UL 854, UL 4703, C(UL) RPVU90 1kV/RPV90 2kV Direct Burial Rated Flame Rated: VW-1/FT1 Federal Spec. A-A ICEA S /NEMA WC-70 For CT use 1/0 and larger Sunlight Resistant Gasoline and Oil Resistant II -40 C rated Suitable for use in 105 C Dry System Single Conductors Part or MCM Nominal Net Weight (lbs./mft) 90 C Wet/Dry XLPE PV / 600 V RHH / RHW-2 PV14VW PV14VW-C PV12VW PV12VW-C PV10VW PV10VW-C PV8VW PV8VW-C PV6VW PV4VW PV3VW PV2VW PV1VW PV1/0VW 1/ PV2/0VW 2/ PV3/0VW 3/ PV4/0VW 4/ PV250VW PV300VW , PV350VW , PV400VW , PV500VW , PV600VW , PV750VW , *Based on ambient temperature of 30 C per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. NOTE: Photovoltaic module interconnection wire for use with or without a raceway in accordance wiht wiring systems Article 690 in the National Electrical Code (NEC), NFPA

16 Single Conductors Single copper conductor, stranded, insulated with moisture and heat resistant cross-linked polyethylene. Rated 2KV to meet the challenging requirements of transformerless inverters on photovoltaic (solar) panel installations. Temperature rating is 90 C in wet and dry applications. Available in colors. Applications: Photovoltaic wire (1,000/2,000 Volt) for use as interconnection wiring on solar panels in grounded or ungrounded systems as defined in applicable parts of the National Electrical Code (NEC) NFPA 70, such as article (A). Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). Photovoltaic Wire ServiceSolar (for use with Solar Panels) VW-1, USE-2 or RHH or RHW-2 1,000/2,000 Volt Copper ASTM B3, B8 and B787 UL 44, UL 854, UL 4703, C(UL) RPVU90 1kV/RPV90 2kV Direct Burial Rated Flame Rated: VW-1/FT1 Federal Spec. A-A ICEA S /NEMA WC-70 For CT use 1/0 and larger Sunlight Resistant Gasoline and Oil Resistant II -40 C rated Suitable for use in 105 C Dry System Part or MCM Nominal Net Weight (lbs./mft) 90 C Wet/Dry 16 XLPE PV / 1KV / 2KV RHH / RHW-2 PV2K14VW PV2K14VW-C PV2K12VW PV2K12VW -C PV2K10VW PV2K10VW-C PV2K8VW PV2K8VW-C PV2K6VW PV2K4VW PV2K3VW PV2K2VW PV2K1VW PV2K1/0VW 1/ PV2K2/0VW 2/ PV2K3/0VW 3/ PV2K4/0VW 4/ PV2K250VW PV2K300VW , PV2K350VW , PV2K400VW , PV2K500VW , PV2K600VW , PV2K750VW , *Based on ambient temperature of 30 C per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. NOTE: Photovoltaic module interconnection wire for use with or without a raceway in accordance wiht wiring systems Article 690 in the National Electrical Code (NEC), NFPA 70.

17 Available with tinned conductors. Single conductor insulated with heat and moisture resistant, cross-linked polyethylene insulation, (Type USE-2), with an overall flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero Lead Jacket. Applications: Photovoltaic wire (600 Volt) for use as interconnection wiring on solar panels in grounded or ungrounded systems as defined in applicable parts of the National Electrical Code (NEC) NFPA 70, such as article (A). EnviroPlus Photovoltaic Wire ServiceSolar (for use with Solar Panels) USE-2 or RHH or RHW-2, Zero Halogen, Limited Smoke Jacket UL 4703 (PV Wire) C(UL) RPV90 600V Conductors UL854 (#16 per UL 66) Direct Burial Rated ICEA S /NEMA WC-70 Flame Rated: VW-1/FT1 For CT Use 1/0 and larger Temperature Rating: 90 C Wet and Dry Sunlight Resistant; Superior Water Resistance Excellent crush and abrasion resistance Gasoline and Oil Resistant II Zero Halogen, Limited Smoke Jacket -40 C Rated Single Conductors Part or MCM Jacket Nominal Net Weight per 1000 feet (lbs.) 30 C Ambient 90 C Wet/Dry PVENV PVENV PVENV PVENV PVENV PVENV PVENV PVENV PVENV PVENV PVENV1/0 1/ PVENV2/0 2/ PVENV3/0 3/ PVENV4/0 4/ PVENV PVENV , PVENV , PVENV , PVENV , PVENV , PVENV , *Per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 17

18 THW Single Conductors Single copper conductor, stranded, insulated with moisture and flame retardant, sunlight resistant polyvinyl chloride compound. Suitable for use in wet or dry locations where conductor temperatures do not exceed 75 C. Available in colors. Application: Type THW is suitable for use in conduit or other recognized raceways for services, feeders and branch circuit wiring. Applications also include general purpose grounding for power and distribution circuits in residential, industrial and commercial buildings. ASTM B3, B8 and B787 UL 83 Flame Rated: VW-1/FT1 Federal Spec. A-A For CT use 1/0 and larger Sunlight Resistant Oil Resistant I NEMA WC70/ICEA S C(UL)US TW75: CSA/UL Listed (#14-500) Part or MCM Nominal Net Weight (lbs/mft) 75 C Wet/Dry TH14SOLBK 14** TH12SOLBK 12** TH10SOLBK 10** TH8SOLBK TH14BK TH12BK TH10BK TH8BK TH6BK TH4BK TH3BK TH2BK TH1BK TH1/0BK 1/ TH2/0BK 2/ TH3/0BK 3/ TH4/0BK 4/ TH250BK TH300BK , TH350BK , TH400BK , TH500BK , TH600BK , TH750BK , TH1000BK 1, , *Based on ambient temperature of 30 C per NEC-Table **Available with 30 mil The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote.

19 THW-2 Single copper conductor, stranded, insulated with moisture and flame retardant, sunlight resistant polyvinyl chloride compound. Suitable for use in wet or dry locations where conductor temperatures do not exceed 90 C. Available in colors. Application: Type THW-2 is suitable for use in conduit or other recognized raceways for services, feeders and branch circuit wiring. Applications also include general purpose grounding for power and distribution circuits in residential, industrial and commercial buildings. ASTM B3, B8 and B787 UL 83 Flame Rated: VW-1/FT1 Federal Spec. A-A For CT use 1/0 and larger Sunlight Resistant (Black only) Oil Resistant I NEMA WC70 / ICEA S Single Conductors Part or MCM Nominal Net Weight (lbs/mft) 90 C Wet/Dry THW14BK THW12BK THW10BK THW8BK THW6BK THW4BK THW3BK THW2BK THW1BK THW1/0BK 1/ THW2/0BK 2/ THW3/0BK 3/ THW4/0BK 4/ THW250BK THW300BK , THW350BK , THW400BK , THW500BK , THW600BK , THW750BK , THW1000BK 1, ,351 1,055 *Based on ambient temperature of 30 C per NEC-Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. 19

20 Single Conductors Copper conductor, solid or stranded, soft (annealed), medium hard, or hard drawn, covered with black high molecular weight polyethylene (HMW-PE). Application: For use in overhead distribution systems where protection from environmental elements is required. Weatherproof Line Wire HMW-PE / Copper Solid/ed, Soft, Medium Hard, Hard Drawn Service Wire line conforms to ASTM standards: B-1 (Hard Drawn) B-2 (Medium Hard Drawn) B-3 (Soft or Annealed) B-8 (Concentric ed Copper) Class A, AA (1-4/0) Conforms to ANSI C8.35 / ICEA S Part or MCM ing Covering Nominal Net Weight per 1000 feet (lbs.) Hard Drawn DC Resistance (Ohms per C Medium Drawn Soft (Annealed) (Amps) PESOS6 6 Solid PESOS4 4 Solid PEST7S WEATHERPROOF LINE WIRE PESOS2 2 Solid PEST7S PEST7S PEST7S1/0 1/ PEST7S2/0 2/ PEST7S3/0 3/ PEST7S4/0 4/ PEST37S PEST37S , PEST37S , PEST37S , ,050 PEST37S , ,253 *Per NEC Table Based on conductor temperature of 80 C; ambient temperature of 40 C; 2 ft./sec. wind. 20

21 Cathodic Protection Cable Description & Features: Cathodic Protection Cable is a stranded copper conductor insulated with a black high molecular weight polyethylene (HMW- PE) compound that provides excellent abrasion, crush, chemical, oil and moisture resistance. Application: Suitable for direct burial for use in cathodic protection systems for pipelines, storage tanks, pilings, well casings, cables, water storage tanks and other buried or water-submerged metallic structures. Specifications & ICEA S Suitable for Direct Burial Chemical, Oil and Moisture Resistant Crush and Abrasion Resistant Sunlight Resistant Construction: Conductor: Soft annealed stranded copper per ASTM B-8 : Black high molecular weight polyethylene (HMW-PE) per ASTM D-1248 Temperature: 75 C Voltage: 600 volts Single Conductors Part Conductor Nominals (In.) Cond. O.D. O.D. Standard Put-up (Reels) Nominal DC Resistance OHMS/ C Product Weight (Lbs./Mft.) CATH ,500, 5, CATH , CATH , CATH ,000, 5, CATH , CATH1/0 1/ , CATH2/0 2/ , CATH4/0 4/ , CATH , CATH , NOTE: All diameters are nominal values; all weights are product weights exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. All sales are subject to Standard Terms & Conditions of Sale. 21

22 Transformer Riser Wire Single Conductors Description & Features: Transformer Riser Wire is a solid or stranded copper conductor covered with a black, high molecular weight polyethylene (HMW- PE) jacket that provides excellent abrasion, crush, chemical, oil, and moisture resistance. Application: A heavy-walled, covered cable for use in uninsulated transformer wire applications. Intended to eliminate faults due to atmospheric conditions, vibrations and faulting caused by objects crossing the leads. Suitable for riser applications at elevated voltages. Specifications & ICEA S Suitable for Direct Burial Chemical, Oil, and Moisture Resistant Crush and Abrasion Resistant Sunlight Resistant Construction: Conductor: Soft annealed copper per ASTM B-3 Covering: Black high molecular weight polyethylene (HMW-PE) per ASTM D-1248 Part Conductor Dimensions Nominal DC Resistant OHMS O.D. per 25C Product Weight Lbs./1000' RISER RISER RISER RISER RISER RISER RISER RISER NOTE: All diameters are nominal values; all weights are product exclusive of packaging. All diameters are subject to standard manufacturing tolerances. All sales are subject to Standard Terms & Conditions of Sale. 22

23 ServicePlex XHHW-2 Twisted Cable THREE CONDUCTOR Multiple single copper conductors, stranded, insulated with moisture, heat and flame resistant, chemically cross-linked polyethylene insulation, and twisted tightly together to effectively function as a single cable. Temperature rating 90 C in wet and dry locations. available in colors. Application: Pre-twisted for easier installation, type XHHW-2, CT is suitable for general purpose wiring, for power distribution and branch circuit wiring where a cable having superior flame retardance is required. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). Part or MCM (mils.) Net Wt. per 1000 ft. (lbs.) SPLEX14/ SPLEX12/ SPLEX10/ SPLEX8/ SPLEX6/ SPLEX4/ SPLEX3/ SPLEX2/ SPLEX1/ SPLEX1/03 1/ ,104 SPLEX2/03 2/ ,376 SPLEX3/03 3/ ,717 SPLEX4/03 4/ ,145 SPLEX250/ ,568 SPLEX350/ ,551 SPLEX500/ ,016 SPLEX600/ ,021 SPLEX750/ ,528 ASTM B3, B8 and B787 UL 44, CSA C22.2 ICEA S /NEMA WC-70 Federal Spec A-A-59544, 90 C Wet/Dry For CT Use 1/0 and Larger Gasoline and Oil Resistant II C(UL) US RW90: CSA/UL Listed Sunlight Resistant -40 C Rated Suitable for Use in 105 C Dry System Appliance Wiring Material: Style 3578 FOUR CONDUCTOR Part or MCM (mils.) Net Wt. per 1000 ft. (lbs.) SPLEX14/ SPLEX12/ SPLEX10/ SPLEX8/ SPLEX6/ SPLEX4/ SPLEX3/ SPLEX2/ SPLEX1/ ,176 SPLEX1/04 1/ ,472 SPLEX2/04 2/ ,835 SPLEX3/04 3/ ,289 SPLEX4/04 4/ ,860 SPLEX250/ ,424 SPLEX350/ ,735 SPLEX500/ ,687 SPLEX600/ ,028 SPLEX750/ ,037 Twisted Cables 23

24 ServicePlex USE-2, RHH or RHW-2 Twisted Cable Twisted Cables THREE CONDUCTOR Multiple single copper conductors, stranded, insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation, and twisted tightly together to effectively function as a single cable. Temperature rating 90 C in wet and dry locations. available in colors. Application: Pre-twisted for easier installation, type USE-2, RHH/RHW-2, CT is suitable for general purpose wiring applications and may be installed in raceway, conduit, direct burial and aerial installations where a cable having superior flame retardance is required. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade). Part or MCM (mils.) Net Wt. per 1000 ft. (lbs.) SPLEX14/3U SPLEX12/3U SPLEX10/3U SPLEX8/3U SPLEX6/3U SPLEX4/3U SPLEX3/3U SPLEX2/3U SPLEX1/3U SPLEX1/03U 1/ ,160 SPLEX2/03U 2/ ,437 SPLEX3/03U 3/ ,783 SPLEX4/03U 4/ ,218 SPLEX250/3U ,649 SPLEX350/3U ,640 SPLEX500/3U ,113 SPLEX600/3U ,166 SPLEX750/3U ,636 ASTM B3, B8 and B787 UL 44 and UL 854, CSA C22.2 ICEA S /NEMA WC-70 C(UL) US RW90 1KV:CSA/UL Listed Federal Spec. A-A For CT Use 1/0 and Larger Gasoline and Oil Resistant II -40 C Rated UL Direct Burial/Sunlight Resistant Suitable for Use in 105 C Dry System FOUR CONDUCTOR Part or MCM (mils.) Net Wt. per 1000 ft. (lbs.) SPLEX14/4U SPLEX12/4U SPLEX10/4U SPLEX8/4U SPLEX6/4U SPLEX4/4U SPLEX3/4U SPLEX2/4U SPLEX1/4U ,240 SPLEX1/04U 1/ ,546 SPLEX2/04U 2/ ,915 SPLEX3/04U 3/ ,378 SPLEX4/04U 4/ ,957 SPLEX250/4U ,532 SPLEX350/4U ,853 SPLEX500/4U ,818 SPLEX600/4U ,212 SPLEX750/4U ,181 24

25 Service Drop XHHW-2 The conductors are stranded, bare soft drawn copper insulated with heat, moisture and sunlight resistant cross-linked polyethylene. The neutral is solid or stranded, bare, hard drawn copper. 2 INSULATED - 1 BARE Part Code Name () ASTM B-1 (Hard Drawn) ASTM B-3 (Soft Drawn or Annealed) ASTM B-8 (Concentric-lay ) ASTM B-787 (Combination Unilay) ICEA S /NEMA WC-70 Conductor rated at 90 C. Single conductors per UL 44 Insulated Conductors Neutral - Messenger Insul. Thick. Hard Drawn () no.) Net Wt. per 1000 ft. (lbs.) (40 C Ambient) TRI8CUSOL Bodoni TRI8CU Garamond TRI6CUSOL Futura TRI6CU Gothic TRI4CUSOL Ionic TRI4CU Caslon TRI2CU Century TRI1/0CU Corinthian 1/ /0 7 1, TRI2/0CU Doric 2/ /0 7 1, TRI3/0CU Tuscan 3/ /0 7 1, TRI4/0CU Composite 4/ /0 7 2, TRI250CU Roman , TRI350CU Helvetica , TRI500CU Deville , Twisted Cables 3 INSULATED - 1 BARE QUAD8CU Huntington QUAD6CUSOL Atlanta QUAD6CU Tallahassee QUAD4CUSOL Baton Rouge QUAD4CU Richmond QUAD2CUSOL Jackson QUAD2CU Seattle QUAD1/0CU Nashville 1/ /0 7 1, QUAD2/0CU Lincoln 2/ /0 7 1, QUAD3/0CU Raleigh 3/ /0 7 2, QUAD4/0CU Denver 4/ /0 7 2, QUAD250CU Pittsburgh , QUAD350CU Houston , QUAD500CU Culloden , *Per NEC Table Ampacity figures are based on conductor temperature of 90 C, ambient temperature of 40 C. 25

26 400 Hz Cable XHHW-2 Twisted Cables The cable conductor shall consist of stranded, bare, soft drawn copper, insulated with cross-linked polyethylene, type XHHW-2. These conductors are rated for 600 volts and carry a maximum temperature rating of 90 C wet/dry. The conductors are twisted in a six around one construction, commonly known as planetary wrap. Conductors will be striped per customer specifications. Application: 400 Hz cable (6 around 1 XHHW-2) is used as a power source for mainframe computers, TV and radio station output power supply, aircraft ground power supplies at airport terminals, plus many other applications. UL 44, ICEA S /NEMA WC-70 ASTM B3, B8 and B787 Features: Lowers overall impedance of circuit, using multiple smaller conductors, which minimize voltage drop; a critical factor for 400 Hz computer power. Readily available in the commonly used sizes with minimal delivery times. *Has the same ratings and is handled in the same manner as any building wire. Geometrically balanced construction allows for a minimum of phase to phase unbalance. The cabled conductors allow for a single, easy, conduit pull. Part or MCM Net Weight per 1000 feet (lbs.) SPLEX4/ ,050 SPLEX2/ ,620 SPLEX1/ , Hz CABLE SPLEX1/07 1/ ,577 SPLEX2/07 2/ ,212 SPLEX3/07 3/ ,007 SPLEX4/07 4/ ,006 SPLEX250/ ,992 SPLEX350/ ,285 SPLEX500/ ,702 *Ampacity is derated due to the fact that this is a multi-conductor assembly. 26

27 400 Hz Cable USE-2, RHH or RHW-2 The cable conductor shall consist of stranded, bare, soft drawn copper, insulated with cross-linked polyethylene, type USE-2. These conductors are rated for 600 volts and carry a maximum temperature rating of 90 C wet/dry. The conductors are twisted in a six around one construction, commonly known as planetary wrap. Conductors will be striped per customer specifications. Application: 400 Hz cable (6 around 1 USE-2) is used as a power source for mainframe computers, TV and radio station output power supply, aircraft ground power supplies at airport terminals, plus many other applications. UL44/UL854, ICEA S /NEMA WC-70 ASTM B3, B8 and B787 Features: Lowers overall impedance of circuit, using multiple smaller conductors, which minimize voltage drop; a critical factor for 400 Hz computer power. Readily available in the commonly used sizes with minimal delivery times. *Has the same ratings and is handled in the same manner as any building wire. Geometrically balanced construction allows for a minimum of phase to phase unbalance. The cabled conductors allow for a single, easy, conduit pull. Twisted Cables Part or MCM Net Weight per 1000 feet (lbs.) SPLEX4/7U ,093 SPLEX2/7U ,671 SPLEX1/7U , Hz CABLE SPLEX1/07U 1/ ,708 SPLEX2/07U 2/ ,354 SPLEX3/07U 3/ ,163 SPLEX4/07U 4/ ,177 SPLEX250/7U ,180 SPLEX350/7U ,493 SPLEX500/7U ,931 *Ampacity is derated due to the fact that this is a multi-conductor assembly. 27

28 Preassembled Aerial Cable XHHW-2 Available with aluminum conductors. 3 or 4 conductors, stranded, bare annealed copper, insulated with heat and moisture resistant cross-linked polyethylene. The conductors shall be cabled with a left hand lay and a messenger of 30% EHS copperweld shall be laid parallel and bound with a flat bare copper binding strap. Standard: ICEA S /NEMA WC-70 Single CDRS are UL 44 Listed NOTE: Optional constructions include: galvanized or stainless steel messengers, PVC coated copper, or PVC coated stainless steel strap. Twisted Cables 3 INSULATED - 1 MESSENGER Part or MCM Messenger ** (Inch) () Net Wt. per 1000 ft. (lbs.) (40 C Ambient) AER1/4C8/ /4 7 # AER1/4C6/ /4 7 # AER1/4C4/ /4 7 # AER1/4C2/ /4 7 # AER1/4C1/ /4 7 # , AER1/4C1/03 1/ /4 7 # , AER5/16C2/03 2/ /16 7 # , AER5/16C3/03 3/ /16 7 # , AER3/8C4/03 4/ /8 7 # , AER3/8C250/ /8 7 # , AER1/2C350/ /2 7 # , AER9/16C500/ /16 7 # , AER9/16C750/ /16 7 # , INSULATED - 1 MESSENGER AER1/4C8/ /4 7 # AER1/4C6/ /4 7 # AER1/4C4/ /4 7 # AER1/4C2/ /4 7 # , AER1/4C1/ /4 7 # , AER5/16C1/04 1/ /16 7 # , AER5/16C2/04 2/ /16 7 # , AER3/8C3/04 3/ /8 7 # , AER3/8C4/04 4/ /8 7 # , AER1/2C250/ /2 7 # , AER1/2C350/ /2 7 # , AER9/16C500/ /16 7 # , AER9/16C750/ /16 7 # , *Per NEC **Messenger size based on 150 span with sag of 2.5 ft. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity.

29 Preassembled Aerial Cable Jacketed EPR, Non-shielded MV-90 2,400 Volt Copper Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant EPR with overall jacket. The conductors shall be cabled with a left hand lay and laid parallel to a 30% EHS copperweld messenger then bound with a flat copper binding strap. Applications: Where NEC jurisdiction applies: 2,400 volt nonshielded power cable, Type MV-90, for conductor temperatures not exceeding 90 C. Part or MCM ICEA S /NEMA WC-71 Single CDRS are UL-1072 Listed NOTE: Optional constructions include: galvanized or stainless steel messengers, PVC coated copper, or PVC coated stainless steel strap. Messenger ** (Inch) () Net Wt. per 1000 ft. (lbs.) (40 C Ambient) Twisted Cables AR1/4C2.4K8/3E /4 7 # AR1/4C2.4K6/3E /4 7 # AR1/4C2.4K4/3E /4 7 # , NON-SHIELDED AR1/4C2.4K2/3E /4 7 # , AR1/4C2.4K1/03E 1/ /4 7 # , AR5/16C2.4K2/03E 2/ /16 7 # , AR3/8C2.4K4/03E 4/ /8 7 # , AR3/8C2.4K250/3E /8 7 # , AR1/2C2.4K350/3E /2 7 # , AR9/16C2.4K500/3E /16 7 # , AR9/16C2.4K750/3E /16 7 # , *Per NEC **Messenger size based on 150 span with sag of 2.5 ft. 29

30 Preassembled Aerial Cable Jacketed EPR, Shielded MV-105 5,000 Volt Copper Class B stranded copper, extruded semi-conductor shield, insulated with heat and moisture resistant EPR, copper shield (stranded or tape), with overall jacket. The conductors shall be cabled with a left hand lay and laid parallel to a 30% EHS copperweld messenger then bound with a flat copper binding strap. ICEA S /NEMA WC-74 Single CDRS are UL-1072 Listed NOTE: Optional constructions include: galvanized or stainless steel messengers, PVC coated copper, or PVC coated stainless steel strap. Twisted Cables Part or MCM Jacket Messenger ** (Inch) () (inch Net Wt. per 1000 ft. (lbs.) (40 C Ambient) AR5/16C5KS6/3E /16 7 # , AR5/16C5KS4/3E /16 7 # , AR5/16C5KS2/3E /16 7 # , SHIELDED AR5/16C5KS1/03E 1/ /16 7 # , AR3/8C5KS2/03E 2/ /8 7 # , AR1/2C5KS4/03E 4/ /2 7 # , AR9/16C5KS250/3E /16 7 # , AR9/16C5KS350/3E /16 7 # , AR9/16C5KS500/3E /16 7 # , AR9/16C5KS750/3E /16 7 # , *Per NEC **Messenger size based on 150 span with sag of 2.5 ft. 30

31 Preassembled Aerial Cable 133% Jacketed EPR MV ,000 Volt Copper Class B stranded copper, extruded semi-conductor shield, insulated with heat and moisture resistant EPR, 133% insulation level, with overall jacket. The conductors shall be cabled with a left hand lay and laid parallel to the 30% EHS copperweld messenger, bound with a rounded-edge flat PVC coated copper binding strap. ICEA S /NEMA WC-74 Single CDRS are UL 1072 Listed NOTE: Optional constructions include: galvanized or stainless steel messengers, PVC coated copper, or PVC coated stainless steel strap. Part or MCM Jacket Messenger ** (Inch) () Net Wt. per 1000 ft. (lbs.) (40 C Ambient) Twisted Cables AR3/8C15K2/3E /8 7 # , % EPR INSULATION AR1/2C15K1/3E /2 7 # , AR1/2C15K1/03E 1/ /2 7 # , AR1/2C15K2/03E 2/ /2 7 # , AR9/16C15K4/03E 4/ /16 7 # , AR9/16C15K250/3E /16 7 # , AR9/16C15K350/3E /16 7 # , AR9/16C15K500/3E /16 7 # , AR9/16C15K750/3E /16 7 # , *Per NEC **Messenger size based on 150 span with sag of 2.5 ft. 31

32 1-ONE 2-TWO SE-R XHHW-2/PVC Service Entrance 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified. Cabled together with bare copper ground conductor. Cable core covered with fiberglass binder tape and overall flame and sunlight resistant grey PVC jacket. UL 44 UL 854 Temperature Rating: 90 C Wet/Dry Color Code: Black and ed Part Grounding Conductor () PVC Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/Dry SER6/3G # SER4/3G # Tray & Power Cables THREE CONDUCTOR SER3/3G # SER2/3G # SER1/3G # , SER1/03G # , SER2/03G # , SER3/03G1/ / , SER4/03G2/ / , * PER NEC TABLE

33 SE-U XHHW-2/PVC 2 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified. Cabled together with Served bare copper ground conductor. Cable core covered with fiberglass binder tape and overall flame and sunlight resistant grey PVC jacket. UL 44 UL 854 Temperature Rating: 90 C Wet/Dry Color Code: K-2 Striped (Except #8 - K-2) Part Grounding Conductor () Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/ Dry SEU8/2G8 SEU # SEU6/2G8 SEU # TWO CONDUCTOR SEU6/2G6 SEU # SEU4/2G6 SEU # SEU4/2G4 SEU # SEU3/2G4 SEU # SEU3/2G3 SEU # SEU2/2G4 SEU # SEU2/2G2 SEU # SEU1/2G1 SEU # Tray & Power Cables SEU1/02G1/0 SEU1/01/01/ / , SEU2/02G2/0 SEU2/02/02/ / , SEU3/02G3/0 SEU3/03/03/ / , SEU4/02G4/0 SEU4/04/04/04/ / , * PER NEC TABLE

34 Tray Cable XHHW-2/PVC Conductors, Class B stranded, annealed copper, insulated with 30 mils heat and moisture resistant cross-linked polyethylene (Type XHHW-2,VW-1), phase identified. Cabled together with fillers and binders (where necessary). flame and sunlight resistant black PVC jacket. Jacket available in colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; UL 1277, IMSA 19-1 Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Two-hour Firewall rated Sunlight Resistant for CT use; Direct Burial, Oil Resistant II Jacket Color Code: K-2 (Optional color codes available) Conductors rated 90 Wet/Dry ICEA S /NEMA WC-70 Conductors rated VW-1, Exposed Runs rated (TC-ER) Part of Conductors Jacket Nominal (inches) Net Weight (lb/1000) TCXH16/2FL 2 (flat) X TCXH16/ Part of Conductors Jacket Nominal (inches) Net Weight (lb/1000) TCXH12/2FL 2 (flat) X TCXH12/ Tray & Power Cables #16 TCXH16/ TCXH16/ TCXH16/ TCXH16/ TCXH16/ TCXH16/ TCXH16/ #12 TCXH12/ TCXH12/ TCXH12/ TCXH12/ TCXH12/ TCXH12/ TCXH12/ TCXH16/ TCXH12/ ,190 TCXH14/2FL 2 (flat) X TCXH10/2FL 2 (flat) X TCXH14/ TCXH10/ TCXH14/ TCXH10/ TCXH14/ TCXH10/ #14 TCXH14/ TCXH14/ #10 TCXH10/ TCXH10/ TCXH14/ TCXH10/ TCXH14/ TCXH10/ TCXH14/ TCXH10/ ,191 TCXH14/ TCXH10/ ,715 NOTE: #16 per UL 66 Fixture Wire type FFH-2 34

35 1-ONE Tray Cable XHHW-2/PVC 2-TWO 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified. Cabled together with fillers (where necessary) and bare copper ground conductor. Cable core covered with binder tape, and overall flame and sunlight resistant black PVC jacket. Jacket available in colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; UL 1277, IMSA 19-1 Flame Rated: IEEE-383 (70,000 BTU) Two-hour Firewall rated, (2/0 and smaller) ICEA T (210,000 BTU) on 1/0 and larger IEEE 1202/CSA FT-4: 1/0 and larger Sunlight Resistant for CT use; Direct Burial, Oil Resistant II Jacket Color Code: Black and numbered (#14 - #8 K-2) (Optional color codes available) Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Exposed runs rated #4 and larger (TC-ER)** THREE CONDUCTOR Part or MCM Grounding Conductor () PVC Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/ Dry TCXH14/3G # TCXH14/3GG # TCXH12/3G # TCXH12/3GG # TCXH10/3G # TCXH10/3GG # TCXH8/3G # TCXH8/3GG # TCXH6/3G # TCXH6/3GG # TCXH4/3G # TCXH3/3G # TCXH2/3G # TCXH1/3G # , TCXH1/03G 1/ # , TCXH2/03G 2/ # , TCXH3/03G 3/ # , TCXH4/03G 4/ # , TCXH250/3G # , TCXH300/3G # , TCXH350/3G # , TCXH400/3G # , TCXH500/3G # , TCXH600/3G # , TCXH750/3G # , Tray & Power Cables * PER NEC TABLE ** ER Rated #6 and smaller with green ground or with no ground. The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. 35

36 1-ONE Tray Cable XHHW-2/PVC 2-TWO 4 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified. Cabled together with fillers (where necessary) and bare copper ground conductor. Cable core covered with binder tape, and overall flame and sunlight resistant black PVC jacket. Jacket available in colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; UL 1277, IMSA 19-1 Flame Rated: IEEE-383 (70,000 BTU) Two-hour Firewall rated, (2/0 and smaller) ICEA T (210,000 BTU) on 1/0 and larger IEEE 1202/CSA FT-4: 1/0 and larger Sunlight Resistant for CT use; Direct Burial, Oil Resistant II Jacket Color Code: Black and numbered (#14 - #8 K-2) (Optional color codes available) Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Exposed runs rated #4 and larger (TC-ER)** Tray & Power Cables 36 FOUR CONDUCTOR Part or MCM Grounding Conductor () PVC Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/ Dry TCXH14/4G # TCXH14/4GG # TCXH12/4G # TCXH12/4GG # TCXH10/4G # TCXH10/4GG # TCXH8/4G # TCXH8/4GG # TCXH6/4G # TCXH6/4GG # TCXH4/4G # TCXH3/4G # , TCXH2/4G # , TCXH1/4G # , TCXH1/04G 1/ # , TCXH2/04G 2/ # , TCXH3/04G 3/ # , TCXH4/04G 4/ # , TCXH250/4G # , TCXH300/4G # , TCXH350/4G # , TCXH400/4G # , TCXH500/4G # , TCXH600/4G # , TCXH750/4G # , * PER NEC TABLE ** ER Rated #6 and smaller with green ground or with no ground. The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity.

37 Tray Cable XHHW-2/ServiceCPE Available with tinned conductors. Conductors, Class B stranded, annealed copper, insulated with 30 mils heat and moisture resistant cross-linked polyethylene (Type RW90/XHHW-2 VW-1,), phase identified. Cabled together with fillers and binders (where necessary). flame and sunlight resistant black CPE jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; RoHS compliant Part of Conductors Jacket Nominal (inches) Net Weight (lb/1000) TCCPE16/2FL UL 1277, IMSA 19-1 CSA C22,2 #239 CIC Flame Rated: IEEE 383 (70,000 BTU) (14 and larger) T (210,000 BTU) (14 and larger) IEEE 1202 / CSA FT-4 (14 and larger) Two-hour Firewall rated Sunlight Resistant for CT use; Direct Burial, Oil Resistant II Jacket Color Code: K-2 (Optional color codes available) Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Exposed runs rated (TC-ER) Conductors rated VW-1 (#14 - #10) -40 C rated Part of Conductors Jacket Nominal (inches) Net Weight (lb/1000) TCCPE12/2FL #16 TCCPE16/ TCCPE16/ TCCPE16/ TCCPE16/ TCCPE16/ TCCPE16/ TCCPE16/ TCCPE16/ #12 TCCPE12/ TCCPE12/ TCCPE12/ TCCPE12/ TCCPE12/ TCCPE12/ TCCPE12/ TCCPE12/ Tray & Power Cables TCCPE16/ TCCPE12/ TCCPE14/2FL TCCPE10/2FL TCCPE14/ TCCPE10/ TCCPE14/ TCCPE10/ TCCPE14/ TCCPE10/ #14 TCCPE14/ TCCPE14/ TCCPE14/ #10 TCCPE10/ TCCPE10/ TCCPE10/ TCCPE14/ TCCPE10/ TCCPE14/ TCCPE10/ TCCPE14/ TCCPE10/ NOTE: #16 per UL 66 Fixture Wire type FFH-2 37

38 1-ONE Tray Cable XHHW-2/ServiceCPE 2-TWO Available with tinned conductors. 3 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type RW90/XHHW-2), phase identified. Cabled together with fillers (where necessary) and bare copper ground conductor. Cable core covered with binder tape, and overall flame and sunlight resistant black CPE jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2, RoHS compliant UL 1277, IMSA 19-1 CSA C22,2 #230 TC Flame Rated: IEEE 383 (70,000 BTU) T (210,000 BTU): Available upon request IEEE 1202 / CSA FT-4: Available upon request Sunlight Resistant for CT use; Direct Burial, Oil Resistant II Jacket Color Code: Black and numbered (#14 - #8 K-2) (Optional color codes available) Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Exposed runs rated #4 and larger (TC-ER) -40 C rated Tray & Power Cables THREE CONDUCTOR Part or MCM Grounding Conductor () Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/ Dry TCCPE14/3G # TCCPE14/3GG # TCCPE12/3G # TCCPE12/3GG # TCCPE10/3G # TCCPE10/3GG # TCCPE8/3G # TCCPE8/3GG # TCCPE6/3G # TCCPE6/3GG # TCCPE4/3G # TCCPE3/3G # TCCPE2/3G # TCCPE1/3G # , TCCPE1/03G 1/ # , TCCPE2/03G 2/ # , TCCPE3/03G 3/ # , TCCPE4/03G 4/ # , TCCPE250/3G # , TCCPE350/3G # , TCCPE500/3G # , TCCPE600/3G # , TCCPE750/3G # , * PER NEC TABLE The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote.

39 1-ONE Tray Cable XHHW-2/ServiceCPE 2-TWO Available with tinned conductors. 4 conductors, stranded, insulated with heat and moisture resistant crosslinked polyethylene (type RW90/XHHW-2), phase identified and Cabled together with fillers (where necessary) and bare copper ground conductor. Cable core covered with binder tape, and overall flame and sunlight resistant black CPE jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; RoHS compliant UL 1277, IMSA 19-1 CSA C22,2 #230 TC Flame Rated: IEEE 383 (70,000 BTU) T (210,000 BTU): Available upon request IEEE 1202 / CSA FT-4: Available upon request Sunlight Resistant for CT use; Direct Burial, Oil Resistant II Jacket Color Code: Black and numbered (#14 - #8 K-2) (Optional color codes available) Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Exposed runs rated #4 and larger (TC-ER) -40 C rated FOUR CONDUCTOR Part or MCM Grounding Conductor () Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/ Dry TCCPE14/4G # TCCPE14/4GG # TCCPE12/4G # TCCPE12/4GG # TCCPE10/4G # TCCPE10/4GG # TCCPE8/4G # TCCPE8/4GG # TCCPE6/4G # TCCPE6/4GG # TCCPE4/4G # TCCPE3/4G # , TCCPE2/4G # , TCCPE1/4G # , TCCPE1/04G 1/ # , TCCPE2/04G 2/ # , TCCPE3/04G 3/ # , TCCPE4/04G 4/ # , TCCPE250/4G # , TCCPE350/4G # , TCCPE500/4G # , TCCPE600/4G # , TCCPE750/4G # , Tray & Power Cables * PER NEC TABLE The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 39

40 Tray Cable XHHW-2/EnviroPlus Factory Mutual Group 1 listed Zero Halogen, Limited Smoke Available with tinned conductors. Conductors are stranded, annealed copper, insulated with 30 mils heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified. Cabled together with fillers (where necessary). Cable core is covered with binder tape, and an overall flame and sunlight resistant black Zero Halogen, Limited Smoke, Zero Lead Jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 UL1277, IMSA 19-1, CSA C22.2 #239 Flame Rated: IEEE 1202/CSA FT-4 IEEE 383, UL1685, UL 1581 Two-hour Firewall rated Sunlight resistant for CT use; Direct Burial Temperature Rating: 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code: K-2 (Optional color codes available) Exposed runs rated (TC-ER) Zero Halogen, Limited Smoke Jacket -40 C Rated Tray & Power Cables 40 #10 #12 #14 Part of Conductors Jacket Nominal (inches)) Net Weight (lb/1000) 30 C Ambient 90 C Wet/Dry TCNH14/ TCNH14/ TCNH14/ TCNH14/ TCNH14/ TCNH14/ TCNH14/ TCNH14/ TCNH14/ TCNH12/ TCNH12/ TCNH12/ TCNH12/ TCNH12/ TCNH12/ TCNH12/ TCNH12/ TCNH12/ , TCNH10/ TCNH10/ TCNH10/ TCNH10/ TCNH10/ TCNH10/ TCNH10/ TCNH10/ TCNH10/ , * Per NEC Table (Ampacity derated in accordance with note 8a). * The overcurrent protection shall not exceed 15 amps for 14, and 20 amps for 12 and 30 amps for 10 per NEC footnote. NOTE: The data shown is approximate and subject to standard industry tolerances

41 1-ONE 2-TWO Available with tinned conductors. Tray Cable XHHW-2/EnviroPlus Factory Mutual Group 1 listed Zero Halogen, Limited Smoke 3 or 4 conductors, stranded copper, insulated with heat and moisture resistant cross-linked polyethylene (Type XHHW-2), phase identified. Cabled together with fillers and bare copper ground conductor. Cable core is covered with binder tape and overall flame and sunlight resistant black Zero Halogen, Limited Smoke, Zero Lead Jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 THREE CONDUCTOR FOUR CONDUCTOR Part or MCM UL1277, IMSA 19-1, CSA C22.2 #230 FlameRated: IEEE 1202/CSA FT-4 IEEE 383, UL1685, UL 1581 Two-hour Firewall rated, (2/0 and smaller) Sunlight resistant for CT use; Direct Burial Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code: Black and numbered (Except #8 is K-2) Zero Halogen, Limited Smoke Jacket Exposed Runs rated (TC-ER) -40 C Rated Grounding Conductor () Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/Dry TCNH8/3G # TCNH8/3GG # TCNH6/3G # TCNH6/3GG # TCNH4/3G # TCNH3/3G # TCNH2/3G # TCNH1/3G # , TCNH1/03G 1/ # , TCNH2/03G 2/ # , TCNH3/03G 3/ # , TCNH4/03G 4/ # , TCNH250/3G # , TCNH350/3G # , TCNH500/3G # , TCNH600/3G # , TCNH750/3G # , TCNH8/4G # TCNH8/4GG # TCNH6/4G # TCNH6/4GG # TCNH4/4G # TCNH3/4G # , TCNH2/4G # , TCNH1/4G # , TCNH1/04G 1/ # , TCNH2/04G 2/ # , TCNH3/04G 3/ # , TCNH4/04G 4/ # , TCNH250/4G # , TCNH350/4G # , TCNH500/4G # , TCNH600/4G # , TCNH750/4G # , *Per NEC-Table NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 41 Tray & Power Cables

42 1-ONE 2-TWO Available with tinned conductors. Tray Cable XHHW-2/EnviroPlus 50% Ground Factory Mutual Group 1 listed Zero Halogen, Limited Smoke 3 or 4 conductors, stranded copper, insulated with heat and moisture resistant cross-linked polyethylene (Type XHHW-2), phase identified. Cabled together with fillers and bare copper ground conductor(s). Cable core is covered with binder tape and overall flame and sunlight resistant black Zero Halogen, Limited Smoke, Zero Lead Jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 UL1277, IMSA 19-1, CSA C22.2 #230 Flame Rated: IEEE 1202/CSA FT-4 IEEE 383, UL1685, UL 1581 Two-hour Firewall rated, (2/0 and smaller) Sunlight resistant for CT use; Direct Burial Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code: Black and numbered (Except #8 is K-2) Zero Halogen, Limited Smoke Exposed Runs rated (TC-ER) -40 C Rated Tray & Power Cables THREE CONDUCTOR Part or MCM Grounding Conductor () Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/Dry TCNH8/3G3# # TCNH6/3G3# # TCNH4/3G3# # TCNH2/3G3# # , TCNH1/3G3# # , TCNH1/03G3#6 1/ # , TCNH2/03G3#6 2/ # , TCNH3/03G3#4 3/ # , TCNH4/03G3#4 4/ # , TCNH250/3G3# # , TCNH350/3G3# # , TCNH500/3G3# # , TCNH750/3G3-2/ / , FOUR CONDUCTOR TCNH8/4G3# # TCNH6/4G3# # TCNH4/4G3# # TCNH2/4G3# # , TCNH1/4G3# # , TCNH1/04G3#6 1/ # , TCNH2/04G3#6 2/ # , TCNH3/04G3#4 3/ # , TCNH4/04G3#4 4/ # , TCNH250/4G3# # , TCNH350/4G3# # , TCNH500/4G3# # , TCNH750/4G3-2/ / , *Per NEC-Table NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity.

43 Tray Cable XHHW-2 / PVC Shielded Available with tinned conductors. Conductors, Class B stranded, annealed copper, insulated with 30 mils heat and moisture resistant cross-linked polyethylene (Type XHHW-2), phase identified. Cabled together with fillers, where necessary. Cable core covered with mylar binder tape, longitudinally applied corrugated copper tape shield, and an overall flame and sunlight resistant black PVC jacket. Jacket available in colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; UL 1277, IMSA 19-1 Flame Rated: IEEE-383 (70,000 BTU) IEEE 1202/CSA FT-4 Two-hour Firewall rated Sunlight Resistant for CT use; Direct Burial, Oil Resistant II Jacket Color Code: K-2 (Optional color codes available) Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Exposed runs rated (TC-ER) Part of Conductors Jacket Nominal (inches)) Net Weight (lb/1000) (30 C Ambient Wet/Dry) 90 C #10 #12 #14 TCXHSHC14/ TCXHSHC14/ TCXHSHC14/ TCXHSHC14/ TCXHSHC14/ TCXHSHC14/ TCXHSHC14/ TCXHSHC14/ TCXHSHC12/ TCXHSHC12/ TCXHSHC12/ TCXHSHC12/ TCXHSHC12/ TCXHSHC12/ TCXHSHC12/ TCXHSHC12/ TCXHSHC12/19 19 TCXHSHC10/ TCXHSHC10/ TCXHSHC10/ TCXHSHC10/ TCXHSHC10/ TCXHSHC10/ TCXHSHC10/ TCXHSHC10/ Tray & Power Cables * Per NEC Table (Ampacity derated in accordance with note 8a) *The overcurrent protection for items marked with an ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. 43

44 1-ONE Tray Cable XHHW-2/PVC Shielded 2-TWO Available with tinned conductors. 3 or 4 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified. Cabled together with fillers (where necessary) and bare copper ground conductor. Cable core covered with mylar binder tape, longitudinally applied corrugated copper tape shield, and overall flame and sunlight resistant black PVC jacket. Jacket available in colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; UL1277, IMSA 19-1 Flame Rated: IEEE-383 (70,000 BTU) IEEE 1202/CSA FT-4 Sunlight Resistant for CT use; Direct Burial, Oil Resistant II Jacket Color Code: Black and numbered (#14 - #8 K-2) Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Exposed runs rated #4 and larger (TC-ER)** Part or MCM Grounding Conductor () PVC Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 C Wet/Dry TCXHSHC14/3G # Tray & Power Cables THREE CONDUCTOR TCXHSHC12/3G # TCXHSHC10/3G # TCXHSHC8/3G # TCXHSHC6/3G # TCXHSHC4/3G # TCXHSHC2/3G # , TCXHSHC1/3G # , TCXHSHC14/4G # FOUR CONDUCTOR TCXHSHC12/4G # TCXHSHC10/4G # TCXHSHC8/4G # TCXHSHC6/4G # TCXHSHC4/4G # TCXHSHC2/4G # , * PER NEC TABLE ** ER Rated #6 and smaller with green ground or with no ground. The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 44

45 Tray Cable XHHW-2/ServiceCPE Shielded Available with tinned conductors. Conductors are stranded, annealed copper, insulated with 30 mils heat and moisture resistant cross-linked polyethylene (type RW90/ XHHW-2), phase identified. Cabled together with fillers (where necessary). Cable core is covered with binder tape, longitudinally applied corrugated copper tape shield, and an overall flame and sunlight resistant black, CPE Jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; UL1277, IMSA 19-1 CSA C22,2 #239 CIC Flame rated: IEEE 1202/CSA FT-4 IEEE 383, UL 1581 Two-hour Firewall rated Sunlight resistant for CT use; Direct Burial Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code K-2 (Optional color codes available) Exposed runs rated (TC-ER) -40 C rated Part of Conductors Jacket Nominal (inches)) Net Weight (lb/1000) (30 C Ambient Wet/Dry) 90 C TCCPESHC14/ TCCPESHC14/ #10 #12 #14 TCCPESHC14/ TCCPESHC14/ TCCPESHC14/ TCCPESHC14/ TCCPESHC14/ TCCPESHC14/ TCCPESHC12/ TCCPESHC12/ TCCPESHC12/ TCCPESHC12/ TCCPESHC12/ TCCPESHC12/ TCCPESHC12/ TCCPESHC12/ TCCPESHC10/ TCCPESHC10/ TCCPESHC10/ TCCPESHC10/ TCCPESHC10/ TCCPESHC10/ TCCPESHC10/ TCCPESHC10/ Tray & Power Cables *Per NEC Table (Ampacity derated in accordance with note 8a) *The overcurrent protection for items marked with an ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. 45

46 1-ONE Tray Cable XHHW-2/ServiceCPE Shielded 2-TWO Available with tinned conductors. 3 or 4 conductors, stranded copper, insulated with heat and moisture resistant cross-linked polyethylene (Type RW90/ XHHW-2), phase identified. Cabled together with fillers and bare copper ground conductor. Cable core is covered with binder tape longitudinally applied corrugated copper tape shield, and overall flame and sunlight resistant black, CPE Jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2; UL1277, IMSA 19-1 CSA C22,2 #230 TC Flame rated: IEEE 1202/CSA FT-4 IEEE 383, UL1685, UL 1581 Two-hour Firewall rated Sunlight resistant for CT use; Direct Burial Conductors rated 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code: Black and numbered (#14 - #8 K-2) Exposed Runs rated (TC-ER) -40 C rated Part or MCM Grounding Conductor () Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 CWet/Dry TCCPESHC14/3G # Tray & Power Cables THREE CONDUCTOR TCCPESHC12/3G # TCCPESHC10/3G # TCCPESHC8/3G # TCCPESHC6/3G # TCCPESHC4/3G # TCCPESHC2/3G # , TCCPESHC1/3G # , TCCPESHC14/4G # FOUR CONDUCTOR TCCPESHC12/4G # TCCPESHC10/4G # TCCPESHC8/4G # TCCPESHC6/4G # TCCPESHC4/4G # TCCPESHC2/4G # , * PER NEC TABLE The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 46

47 Tray Cable XHHW-2/EnviroPlus Shielded Factory Mutual Group 1 listed Zero Halogen, Limited Smoke Available with tinned conductors. Conductors are stranded, annealed copper, insulated with 30 mils heat and moisture resistant cross-linked polyethylene (type XHHW-2 VW-1), phase identified. Cabled together with fillers (where necessary). Cable core is covered with binder tape, longitudinally applied corrugated copper tape shield, and an overall flame and sunlight resistant black Zero Halogen, Limited Smoke, Zero Lead Jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 UL1277, IMSA 19-1, CSA C22.2 #239 Flame rated: IEEE 1202/CSA FT-4 IEEE 383, UL1685, UL 1581 Two-hour Firewall rated Sunlight resistant for CT use; Direct Burial Conductors Rated 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code: K-2 (Optional color codes available) Exposed runs rated (TC-ER) Zero Halogen, Limited Smoke Jacket -40 C Rated #10 #12 #14 Part of Conductors Jacket Nominal (inches) Net Weight (lb/1000) (30 C Ambient Wet/Dry) 90 C TCNHSHC14/ TCNHSHC14/ TCNHSHC14/ TCNHSHC14/ TCNHSHC14/ TCNHSHC14/ TCNHSHC14/ TCNHSHC14/ TCNHSHC12/ TCNHSHC12/ TCNHSHC12/ TCNHSHC12/ TCNHSHC12/ TCNHSHC12/ TCNHSHC12/ TCNHSHC12/ TCNHSHC10/ TCNHSHC10/ TCNHSHC10/ TCNHSHC10/ TCNHSHC10/ TCNHSHC10/ TCNHSHC10/ TCNHSHC10/ Tray & Power Cables *Per NEC Table (Ampacity derated in accordance with note 8a) *The overcurrent protection for items marked with an ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. 47

48 1-ONE 2-TWO Tray Cable XHHW-2/EnviroPlus Shielded Factory Mutual Group 1 listed Zero Halogen, Limited Smoke Available with tinned conductors. 3 or 4 conductors, stranded copper, insulated with heat and moisture resistant cross-linked polyethylene (Type XHHW-2), phase identified. Cabled together with fillers and bare copper ground conductor. Cable core is covered with binder tape longitudinally applied corrugated copper tape shield, and overall flame and sunlight resistant black Zero Halogen, Limited Smoke, Zero Lead Jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 UL1277, IMSA 19-1, CSA C22.2 #230 Flame rated: IEEE 1202/CSA FT-4 IEEE 383, UL1685, UL 1581 Two-hour Firewall rated Sunlight resistant for CT use; Direct Burial Conductors Rated 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code: Black and numbered (#14 - #8 K-2) Zero Halogen, Limited Smoke Jacket Exposed Runs rated (TC-ER) -40 C Rated Part or MCM Grounding Conductor () PVC Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient) 90 CWet/Dry TCNHSHC14/3G # Tray & Power Cables THREE CONDUCTOR TCNHSHC12/3G # TCNHSHC10/3G # TCNHSHC8/3G # TCNHSHC6/3G # TCNHSHC4/3G # TCNHSHC2/3G # , TCNHSHC1/3G # , TCNHSHC14/4G # FOUR CONDUCTOR TCNHSHC12/4G # TCNHSHC10/4G # TCNHSHC8/4G # TCNHSHC6/4G # TCNHSHC4/4G # TCNHSHC2/4G # , * PER NEC TABLE The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12 and 30 amps for 10 per NEC footnote. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 48

49 Tray Cable Nonshielded (100%)/Shielded (133%) MV-90/MV-105 2,400/5,000 Volt Copper Nonshielded: Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant EPR (2,400 Volt rated). Shielded: Class B stranded copper, extruded semi-conductor shield, insulated with heat and moisture resistant EPR, 133% insulation level, with overall jacket. 3 conductors, phase identified and cabled together with fillers and bare copper ground conductor(s). Cable core covered with binder tape and overall flame and sunlight resistant black PVC jacket. Jacket available in colors. UL 1072 Sunlight Resistant Direct Burial, For CT use Color Code K-2 Stripes Conductors rated at 105 C (5kV) / 90 C (2.4kV) Oil Resistant II Jacket Non-shielded: ICEA S /NEMA WC-71 Shielded: ICEA S /NEMA WC-74 NON-SHIELDED SHIELDED Part or MCM Conductor Jacket over Single Cond. Copper Grounding Conductor(s) () PVC Jacket Net Weight per 1000ft. (lbs.) P2.4K8/3EG P2.4K6/3EG , P2.4K4/3EG , P2.4K2/3EG , P2.4K1/03EG 1/ , P2.4K2/03EG 2/ , P2.4K4/03EG 4/ , P2.4K250/3EG , P2.4K350/3EG , P2.4K500/3EG , P2.4K750/3EG / , P5KS6/3EG , P5KS4/3EG , P5KS2/3EG , P5KS1/3EG , P5KS1/03EG 1/ , P5KS2/03EG 2/ , P5KS4/03EG 4/ , P5KS250/3EG , P5KS350/3EG , P5KS500/3EG , P5KS750/3EG / , (40 C Ambient) Tray & Power Cables * Per NEC Table Based on one three-conductor cable. 49

50 Tray Cable 133% Jacketed EPR MV ,000 Volt Copper Class B stranded copper, extruded semi-conductor shield, insulated with heat and moisture resistant EPR, 133% insulation level, with overall jacket. Phase identified and cabled together with fillers and bare copper ground conductor. Cable core covered with binder tape and overall flame and sunlight resistant black PVC jacket. Jacket available in colors. UL 1072 Sunlight Resistant Direct Burial, For CT use Color Code K-2 Stripes Conductors rated at 105 C ICEA S /NEMA WC-74 Oil Resistant II Jacket Part or MCM Conductor Jacket over Single Cond. Copper Grounding Conductor(s) () PVC Jacket Net Weight per 1000ft. (lbs.) (40 C Ambient) Tray & Power Cables P15K2/3EG , P15K1/3EG , P15K1/03EG 1/ , P15K2/03EG 2/ , P15K4/03EG 4/ , P15K250/3EG , P15K350/3EG , P15K500/3EG , P15K750/3EG / , * Per NEC Table Based on one three-conductor cable. 50

51 1-ONE 2-TWO Tray Cable ServiceDrive ASD/VFD XHHW-2/PVC Shielded (Patented) Available with tinned conductors. 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Jacket available in colors. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 For use in ASD / VFD applications; UL 1277 Flame Rated: IEEE 383 (70,000 BTU) ICEA T (210,000 BTU) on 1/0 and larger IEEE 1202 / CSA FT-4 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant, for CT use; Direct Burial Oil Resistant II Jacket Code: Black and ed Conductors rated 90 C Wet/Dry ICEA S / NEMA WC-70 Exposed runs rated #4 and larger (TC-ER) 600 Volt Tray Cable Part or MCM Copper Grounding Conductor(s) () PVC Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient Wet/Dry) ASDPTC14/ # ASDPTC12/ # ASDPTC10/ # ASDPTC8/ # ASDPTC6/ # THREE CONDUCTOR ASDPTC4/ # ASDPTC3/ # ASDPTC2/ # , ASDPTC1/ # , ASDPTC1/03 1/ # , ASDPTC2/03 2/ # , ASDPTC3/03 3/ # , ASDPTC4/03 4/ # , ASDPTC250/ # , ASDPTC350/ # , ASDPTC500/ # , ASDPTC600/ / , ASDPTC750/ / , *Per NEC Table The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. Note: The data shown is approximate and subject to standard industry tolerances. ASD/VFD ServiceDrive System 51

52 1-ONE 2-TWO Available with tinned conductors. 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black zero-halogen, limited smoke, zero lead jacket. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 For use in ASD / VFD applications Tray Cable ServiceDrive Plus ASD/VFD XHHW-2/EnviroPlus Shielded (Patented) Factory Mutual Group 1 Listed, Zero Halogen, Limited Smoke, Lead Free UL 1277, CSA C22.2 #230 Flame Rated: IEEE 383 (70,000 BTU) IEEE 1202 / CSA FT-4, UL 1685 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant, for CT use; Direct Burial Color Code: Black and ed Conductors rated 90 C Wet/Dry ICEA S / NEMA WC-70 Zero Halogen, Limited Smoke Jacket Exposed Runs rated (TC-ER) 600 Volt Tray Cable -40 C Rated Part or MCM Copper Grounding Conductor(s) () Jacket Net Wt. per 1000 ft. (lbs.) (30 C Ambient Wet/Dry) ASDETC14/ # ASDETC12/ # ASDETC10/ # ASDETC8/ # ASDETC6/ # ASD/VFD ServiceDrive System THREE CONDUCTOR ASDETC4/ # ASDETC3/ # ASDETC2/ # , ASDETC1/ # , ASDETC1/03 1/ # , ASDETC2/03 2/ # , ASDETC3/03 3/ # , ASDETC4/03 4/ # , ASDETC250/ # , ASDETC350/ # , ASDETC500/ # , ASDETC600/ / , ASDETC750/ / , *Per NEC Table The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. Note: The data shown is approximate and subject to standard industry tolerances. 52

53 1-ONE 2-TWO Jacketed MC ServiceDrive ASD/VFD XHHW-2 Available with tinned conductors. 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers** and 3 symmetrical copper ground conductors. Cable core covered with binder tape, 5-mil helical copper tape shield, galvanized steel interlocked armor, with flame and sunlight resistant PVC jacket overall. Jacket available in colors. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 For use in ASD / VFD applications UL 1569 Flame Rated: IEEE 383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202 / CSA FT-4 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant, for CT Use; Direct Burial 1 Oil Resistant II Jacket Color Code: Black and ed Temperature Rating: 90 C Wet / Dry ICEA S / NEMA WC-70 Part or MCM Copper Grounding Conductors () over Armor PVC Jacket Net Weight per 1000 feet (lbs.) (30 C Ambient Wet/Dry) 90 C ASDP14/ # ASDP12/ # ASDP10/ # ASDP8/ # ASDP6/ # THREE CONDUCTOR ASDP4/ # ASDP3/ # , ASDP2/ # , ASDP1/ # , ASDP1/03 1/ # , ASDP2/03 2/ # , ASDP3/03 3/ # , ASDP4/03 4/ # , ASDP250/ # , ASDP350/ # , ASDP500/ # , ASDP600/ / , ASDP750/ / , ASD/VFD ServiceDrive System *Per NEC Table Includes encasement in concrete. **Fillers used when required. The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. Note: The data shown is approximate and subject to standard industry tolerances. 53

54 1-ONE 2-TWO Available with tinned conductors. Jacketed MC ServiceDrive Plus ASD/VFD XHHW-2, Factory Mutual Group 1 Listed Zero Halogen, Limited Smoke 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical copper ground conductors. Cable core covered with binder tape, 5-mil helical copper tape shield, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant zero halogen, limited smoke, zero lead jacket overall. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 For use in ASD / VFD applications. UL 1569 Flame Rated: IEEE 383 (70,000 BTU) IEEE 1202 / CSA FT-4, UL 1685 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant, for CT Use; Direct Burial 1 Color Code: Black and ed Temperature Rating: 90 C Wet / Dry ICEA S / NEMA WC-70 Zero Halogen, Limited Smoke Jacket -40 C Rated Part or MCM Copper Grounding Conductors () over Armor Jacket Net Weight per 1000 feet (lbs.) (30 C Ambient Wet/Dry) 90 C ASDE14/ # ASDE12/ # ASDE10/ # ASDE8/ # ASDE6/ # ASD/VFD ServiceDrive System THREE CONDUCTOR ASDE4/ # ASDE3/ # , ASDE2/ # , ASDE1/ # , ASDE1/03 1/ # , ASDE2/03 2/ # , ASDE3/03 3/ # , ASDE4/03 4/ # , ASDE250/ # , ASDE350/ # , ASDE500/ # , ASDE600/ / , ASDE750/ / , *Per NEC Table Includes encasement in concrete. **Fillers used when required. + The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. Note: The data shown is approximate and subject to standard industry tolerances.

55 Tray Cable Termination Kit/Connectors ServiceDrive and ServiceDrive Plus ASD/VFD Corresponding Part s or MCM Cable Part Connector Part Termination Kit Part 14 ASDPTC14/3 CONASDTC14/3 TERASD14-1/3 12 ASDPTC12/3 CONASDTC12/3 TERASD14-1/3 10 ASDPTC10/3 CONASDTC10/3 TERASD14-1/3 8 ASDPTC8/3 CONASDTC8/3 TERASD14-1/3 6 ASDPTC6/3 CONASDTC6/3 TERASD14-1/3 4 ASDPTC4/3 CONASDTC4/3 TERASD14-1/3 3 ASDPTC3/3 CONASTCD3/3 TERASD14-1/3 2 ASDPTC2/3 CONASDTC2/3 TERASD14-1/3 1 ASDPTC1/3 CONASDTC1/3 TERASD14-1/3 1/0 ASDPTC1/03 CONASDTC1/03 TERASD1/0-3/03 2/0 ASDPTC2/03 CONASDTC2/03 TERASD1/0-3/03 3/0 ASDPTC3/03 CONASDTC3/03 TERASD1/0-3/03 4/0 ASDPTC4/03 CONASDTC4/03 TERASD4/0-400/3 250 ASDPTC250/3 CONASDTC250/3 TERASD4/0-400/3 350 ASDPTC350/3 CONASDTC350/3 TERASD4/0-400/3 500 ASDPTC500/3 CONASDTC500/3 TERASD /3 600 ASDPTC600/3 CONASDTC600/3 TERASD /3 750 ASDPTC750/3 CONASDTC750/3 TERASD /3 ASD/VFD ServiceDrive System 55 Made in the USA

56 Jacketed MC Termination Kit/Connectors ServiceDrive and ServiceDrive Plus ASD/VFD Corresponding Part s or MCM Cable Part Connector Part Termination Kit Part 14 ASDE14/3 CONASD14/3 TERASD14-1/3 12 ASDE12/3 CONASD12/3 TERASD14-1/3 10 ASDE10/3 CONASD10/3 TERASD14-1/3 8 ASDE8/3 CONASD8/3 TERASD14-1/3 6 ASDE6/3 CONASD6/3 TERASD14-1/3 4 ASDE4/3 CONASD4/3 TERASD14-1/3 3 ASDE3/3 CONASD3/3 TERASD14-1/3 2 ASDE2/3 CONASD2/3 TERASD14-1/3 1 ASDE1/3 CONASD1/3 TERASD14-1/3 1/0 ASDE1/03 CONASD1/03 TERASD1/0-3/03 ASD/VFD ServiceDrive System 2/0 ASDE2/03 CONASD2/03 TERASD1/0-3/03 3/0 ASDE3/03 CONASD3/03 TERASD1/0-3/03 4/0 ASDE4/03 CONASD4/03 TERASD4/0-400/3 250 ASDE250/3 CONASD250/3 TERASD4/0-400/3 350 ASDE350/3 CONASD350/3 TERASD4/0-400/3 500 ASDE500/3 CONASD500/3 TERASD /3 600 ASDE600/3 CONASD600/3 TERASD /3 750 ASDE750/3 CONASD750/3 TERASD /3 56 Made in the USA

57 Tray Cable Connectors ServiceDrive ASD/VFD Patented for use with ServiceDrive and ServiceDrive Plus Cable Systems Description & Features: These patented connectors are designed exclusively to terminate ASD/VFD cables in control centers, panel boards, junction boxes and motor control enclosures. Listings: Class 1, Div. 2 and Class 2, Div. 1 & 2 CSA Standard: C22.2 #18.98 NEMA 4 IP65 Thread Type: NPT Part Wire Hub Set Screw CONASDTC14/ COND 3/4 10/32 X 1/4 CONASDTC12/ COND 3/4 10/32 X 1/4 CONASDTC10/ COND 3/4 10/32 X 1/4 CONASDTC8/3 8 3 COND 3/4 10/32 X 1/4 CONASDTC6/3 6 3 COND 3/4 10/32 X 1/4 CONASDTC4/3 4 3 COND 1 1/4-20 X 1/4 CONASDTC3/3 3 3 COND 1 10/32 X 1/4 CONASDTC2/3 2 3 COND 1-1/4 1/4-20 X 1/4 CONASDTC1/3 1 3 COND 1-1/4 1/4-20 X 1/4 CONASDTC1/03 1/0 3 COND 1-1/2 1/4-20 X 1/4 CONASDTC2/03 2/0 3 COND 1-1/2 1/4-20 X 1/4 CONASDTC3/03 3/0 3 COND 1-1/2 1/4-20 X 1/4 CONASDTC4/03 4/0 3 COND 1-1/2 1/4-20 X 5/16 CONASDTC250/3 250 MCM 3 COND 2 1/4-20 X 5/16 CONASDTC300/3 300 MCM 3 COND 2 5/16-18 X 3/8 CONASDTC350/3 350 MCM 3 COND 2 5/16-18 X 3/8 CONASDTC400/3 400 MCM 3 COND 2 5/16-18 X 3/8 CONASDTC500/3 500 MCM 3 COND 2-1/2 5/16-18 X 3/8 CONASDTC600/3 600 MCM 3 COND 2-1/2 5/16-18 X 3/8 CONASDTC750/3 750 MCM 3 COND 3 5/16-18 X 3/8 ASD/VFD ServiceDrive System 57

58 Jacketed MC Connectors ServiceDrive ASD/VFD For use with ServiceDrive and ServiceDrive Plus Cable System Description & Features: These patented connectors are designed exclusively to terminate ASD/VFD cables in control centers, panel boards, junction boxes and motor control enclosures. Listings: Class 1, Div. 2 and Class 2, Div. 1 & 2 CSA Standard: C22.2 #18.98 NEMA 4 IP65 Thread Type: NPT Part Wire Hub Set Screw CONASD14/ COND 3/4 10/32 X 1/4 CONASD12/ COND 3/4 10/32 X 1/4 CONASD10/ COND 3/4 10/32 X 1/4 CONASD8/3 8 3 COND 3/4 10/32 X 1/4 CONASD6/3 6 3 COND 1-1/4 1/4-20 X 1/4 CONASD4/3 4 3 COND 1-1/4 1/4-20 X 1/4 CONASD3/3 3 3 COND 1-1/4 1/4-20 X 1/4 CONASD2/3 2 3 COND 1-1/4 1/4-20 X 1/4 CONASD1/3 1 3 COND 1-1/4 1/4-20 X 1/4 CONASD1/03 1/0 3 COND 1-1/2 1/4-20 X 1/4 ASD/VFD ServiceDrive System CONASD2/03 2/0 3 COND 1-1/2 1/4-20 X 1/4 CONASD3/03 3/0 3 COND 1-1/2 1/4-20 X 1/4 CONASD4/03 4/0 3 COND 2 1/4-20 X 5/16 CONASD250/3 250 MCM 3 COND 2 1/4-20 X 5/16 CONASD300/3 300 MCM 3 COND 2 1/4-20 X 5/16 CONASD350/3 350 MCM 3 COND 2-1/2 5/16-18 X 3/8 CONASD400/3 400 MCM 3 COND 2-1/2 5/16-18 X 3/8 CONASD500/3 500 MCM 3 COND 2-1/2 5/16-18 X 3/8 CONASD600/3 600 MCM 3 COND 3 5/16-18 X 3/8 CONASD750/3 750 MCM 3 COND 3 5/16-18 X 3/8 58

59 Tray Cable ASD/VFD Termination Kit For use with ServiceDrive and ServiceDrive Plus Armor and Tray Cable Features: 1. Flat tinned Copper braid Woven tinned copper construction 2. Stainless steel spring clamp 3. Adhesive-backed copper foil tape Shields against EMI/RFI radiation. Conductive through the adhesive. Applications: Used to properly terminate the helically applied copper tape shield of ASD/VFD cable constructions. Listings: Braid QC-W-343 Type S and ASTM B-33 Copper Foil Tape UL 510 for flame retardancy Part Description TERASD14-1/3 For use with 14-1 shielded armor and tray cable TERASD1/0-3/03 For use with 1/0-3/0 shielded armor and tray cable TERASD4/0-400/3 For use with 4/0-400 MCM shielded armor and tray cable TERASD /3 For use with 500 MCM MCM shielded armor and tray cable ASD/VFD ServiceDrive System 59

60 Jacketed MC ASD/VFD Termination Kit For use with ServiceDrive and ServiceDrive Plus Cable Systems Applications: Used to properly terminate the helically applied copper tape shield of ASD/VFD cable constructions. Features: 1. Flat tinned Copper braid Woven tinned copper construction 2. Stainless steel spring clamp 3. Adhesive-backed copper foil tape Shields against EMI/RFI radiation. Conductive through the adhesive. Listings: Braid QC-W-343 Type S and ASTM B-33 Copper Foil Tape UL 510 for flame retardancy Part Description TERASD14-1/3 For use with 14 awg - 1 awg shielded armor and tray cable TERASD1/0-3/03 For use with 1/0 awg - 3/0 awg shielded armor and tray cable TERASD4/0-400/3 For use with 4/0 awg mcm shielded armor and tray cable TERASD /3 For use with 500 mcm mcm shielded armor and tray cable ASD/VFD ServiceDrive System 60

61 Feeder MC XHHW-2 Manufacturing quality. Delivering service. Armored Cable 3 or 4 conductors, stranded, insulated with heat & moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** & green or bare ground conductor. Cable core covered with binder tape, aluminum or galvanized steel interlocked armor. Jacket available upon request. Applications Service Wire s Feeder MC cable is designed to be a cost effective replacement for conduit & wire. Suitable for service, branch & feeder circuits. Ideal for use in commercial, industrial & utility applications. This flexible cable assembly offers: labor/time savings, an increased resistance to mechanical damage, system design flexibility & the reliability of a factory assembled & tested cable system. UL 1569, ICEA S /NEMA WC-70 NEC Article 330 Cable Tray Rated 600 Volt, 90 C rated Color coding: K1 solid colors (#8-#1). Black and ed (1/0 and larger). Green ground on #1 and smaller. Bare ground on 1/0 and larger. Features Suitable for use in NEC hazardous locations: Class I, Div. 2 Class II, Div. 2 Two-hour Firewall rated, (2/0 and smaller) For use in Theatres (Article 520), Motion Picture & TV Studios (Article 530) & Places of Assembly with more than 100 people Can be messenger supported (Article 330) Part or MCM Insulated/Bare Copper Grounding Conductor(s) () over Armor Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (30 C Ambient Wet/Dry) 90 C THREE CONDUCTOR TWO MC8/ MC6/ MC8/ MC6/ MC4/ MC3/ MC2/ , MC1/ ,190 1, MC1/03 1/ ,398 1, MC2/03 2/ ,689 1, MC3/03 3/ ,098 2, MC4/03 4/ ,586 2, MC250/ ,123 3, MC300/ ,654 4, MC350/ ,224 4, MC400/ ,712 5, MC500/ ,842 6, MC600/ ,948 7, MC750/ ,618 9, *Per NEC Table **Fillers used when required. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 61

62 Armored Cable Feeder MC XHHW-2 Manufacturing quality. Delivering service. 3 or 4 conductors, stranded, insulated with heat & moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** & green or bare ground conductor. Cable core covered with binder tape, aluminum or galvanized steel interlocked armor. Jacket available upon request. Applications Service Wire s Feeder MC cable is designed to be a cost effective replacement for conduit & wire. Suitable for service, branch & feeder circuits. Ideal for use in commercial, industrial & utility applications. This flexible cable assembly offers: labor/time savings, an increased resistance to mechanical damage, system design flexibility & the reliability of a factory assembled & tested cable system. UL 1569, ICEA S /NEMA WC-70 NEC Article 330 Cable Tray Rated 600 Volt, 90 C rated Color coding: K1 solid colors (#8-#1). Black and ed (1/0 and larger). Green ground on #1 and smaller. Bare ground on 1/0 and larger. Features Suitable for use in NEC hazardous locations: Class I, Div. 2 Class II, Div. 2 Two-hour Firewall rated, (2/0 and smaller) For use in Theatres (Article 520), Motion Picture & TV Studios (Article 530) & Places of Assembly with more than 100 people Can be messenger supported (Article 330) Part or MCM Insulated/Bare Copper Grounding Conductor(s) () over Armor Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (30 C Ambient Wet/Dry) 90 C MC8/ MC6/ MC4/ MC3/ ,010 1, MC2/ ,237 1, MC1/ ,507 1, FOUR CONDUCTOR MC1/04 1/ ,789 2, MC2/04 2/ ,174 2, MC3/04 3/ ,700 3, MC4/04 4/ ,295 3, MC250/ ,027 4, MC300/ ,717 5, MC350/ ,465 5, MC400/ ,104 6, MC500/ ,585 8, MC600/ ,040 9, MC750/ ,212 11, *Per NEC Table **Fillers used when required. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 62

63 Feeder MC Connectors Armored Cable Description & Features: These U.L. listed connectors are a one-piece body construction with a unique scroll design that can provide a 360 degree ground to armor. This connector provides a fast and easy installation, eliminates internal components, prevents cable pullout and saves time and labor. Listings: UL: Class I* Group A, B, C and D Class II* Group E, F and G Class III * Includes Division 1 and Division 2 Construction Suitable for industrial and commercial use. Manufactured from 6061 copper-free aluminum. A complete range of NPT (National Pipe Thread) sizes are available from 1/2" through 4". This accommodates armored cable type MC O.D. sizes. Copper MC Part O.D. Range Copper MC Part O.D. Range Copper MC Part O.D. Range 8/3 MC CON /4 MC CON /4 MC CON /4 MC CON /3 MC CON /3 MC CON /2 MC CON /4 MC CON /4 MC CON /3 MC CON /03 MC CON /3 MC CON /4 MC CON /04 MC CON /4 MC CON /2 MC CON /03 MC CON /3 MC CON /3 MC CON /04 MC CON /4 MC CON /4 MC CON /03 MC CON /3 MC CON /3 MC CON /04 MC CON /4 MC CON /4 MC CON /03 MC CON /3 MC CON /3 MC CON /04 MC CON /4 MC CON /3 MC CON

64 Armored Cable Jacketed MC XHHW-2 Manufacturing quality. Delivering service. Conductors are Class B stranded copper, 30 mils, Type XHHW-2, phase identified, and cabled together with a **bare copper ground conductor. Cable Core covered with binder tape, Aluminum or Galvanized steel interlocked Armor, with an overall flame and sunlight resistant PVC Jacket. Jacket available under armor & in colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2 Class II, Div. 2 UL 1569 Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Two-hour Firewall rated Sunlight Resistant for CT use; Direct Burial 1, Oil Resistant II Jacket Color Code K-2 / other color codes available Temperature Rating: 90 C Wet/Dry ICEA S /NEMA WC-70 #10 #12 #14 Part of Conductors Grounding Conductors () over Armor PVC Jacket Approximate Alum. Armor Net Wt. per 1000 ft. (lbs.) Galv. Armor (30 C Ambient Wet/Dry) 90 C AAP14/ AAP14/ AAP14/ AAP14/ AAP14/ AAP14/ AAP14/ AAP14/ AAP14/ AAP14/ , AAP12/ AAP12/ AAP12/ AAP12/ AAP12/ AAP12/ AAP12/ AAP12/ AAP12/ , AAP12/ ,336 1, AAP10/ AAP10/ AAP10/ AAP10/ AAP10/ AAP10/ AAP10/ AAP10/ ,049 1, AAP10/ ,348 1, AAP10/ ,907 2, *Per NEC Table (Ampacity derated in accordance with note 8a) Includes encasement in concrete. The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. ** Cable with 7 conductors or more shall have a green insulated ground. NOTE: The data shown is approximate and subject to standard industry tolerances 64

65 1-ONE 2-TWO Jacketed MC XHHW-2 Manufacturing quality. Delivering service. Armored Cable 3 or 4 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** and bare copper ground conductor(s). Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant black PVC jacket. Jacket available under armor and in colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2 Class II, Div. 2 UL 1569 Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant for CT use; Direct Burial 1, Oil Resistant II Jacket Color Code Black and ed / other color codes available Temperature rating at 90 C Wet/Dry ICEA S /NEMA WC-70 THREE CONDUCTOR FOUR CONDUCTOR Part or MCM Grounding Conductor () over Armor (inch Jacket Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (30 C Ambient Wet/Dry) 90 C AAP8/ # AAP6/ # AAP4/ # AAP3/ # , AAP2/ # ,030 1, AAP1/ # ,243 1, AAP1/03 1/ # ,515 1, AAP2/03 2/ # ,814 2, AAP3/03 3/ # ,262 2, AAP4/03 4/ # ,725 3, AAP250/ # ,305 3, AAP300/ # ,881 4, AAP350/ # ,425 4, AAP400/ # ,966 5, AAP500/ # ,134 6, AAP600/ # ,301 7, AAP750/ # ,955 9, AAP8/ # AAP6/ # AAP4/ # , AAP3/ # ,084 1, AAP2/ # ,287 1, AAP1/ # ,598 1, AAP1/04 1/ # ,914 2, AAP2/04 2/ # ,340 2, AAP3/04 3/ # ,873 3, AAP4/04 4/ # ,484 3, AAP250/ # ,219 4, AAP300/ # ,866 5, AAP350/ # ,744 6, AAP400/ # ,451 6, AAP500/ # ,894 8, AAP600/ # ,425 10, AAP750/ # ,619 12, *Per NEC Table Includes encasement in concrete. **Fillers used when required. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 65

66 Armored Cable 1-ONE 2-TWO Jacketed MC XHHW-2 50% Ground Manufacturing quality. Delivering service. 3 or 4 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** and bare copper ground conductor (3 segmented grounds). Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant black PVC jacket. Jacket available under armor and in colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2 Class II, Div. 2 UL 1569 Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant for CT use; Direct Burial 1, Oil Resistant II Jacket Color Code Black and ed / other color codes available Temperature rating at 90 C Wet/Dry ICEA S /NEMA WC-70 THREE CONDUCTOR Part or MCM Copper Grounding Conductors () over Armor (inch PVC- Jacket Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (30 C Ambient Wet/Dry) 90 C AAP8/3G3# # AAP6/3G3# # AAP4/3G3# # AAP3/3G3# # , AAP2/3G3# # ,103 1, AAP1/3G3# # ,317 1, AAP1/03G3#6 1/ # ,680 1, AAP2/03G3#6 2/ # ,980 2, AAP3/03G3#4 3/ # ,525 2, AAP4/03G3#4 4/ # ,988 3, AAP250/3G3# # ,551 3, AAP300/3G3# # ,191 4, AAP350/3G3# # ,855 5, AAP400/3G3# # ,398 5, AAP500/3G3# # ,681 7, AAP600/3G3-1/ / ,042 8, AAP750/3G3-2/ / ,891 10, FOUR CONDUCTOR AAP8/4G3# # AAP6/4G3# # AAP4/4G3# # , AAP3/4G3# # ,100 1, AAP2/4G3# # ,360 1, AAP1/4G3# # ,672 1, AAP1/04G3#6 1/ # ,079 2, AAP2/04G3#6 2/ # ,506 2, AAP3/04G3#4 3/ # ,136 3, AAP4/04G3#4 4/ # ,747 4, AAP250/4G3# # ,466 4, AAP300/4G3# # ,277 5, AAP350/4G3# # ,176 6, AAP400/4G3# # ,883 7, AAP500/4G3# # ,442 8, AAP600/4G3-1/ / ,167 10, AAP750/4G3-2/ / ,555 13, *Per NEC Table Includes encasement in concrete. **Fillers used when required. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity.

67 Jacketed MC Connectors Water Tight Armored Cable Description & Features: These U.L. listed connectors are a one-piece body construction with a unique scroll design that can provide a 360 degree ground to armor. This connector provides a fast and easy installation, eliminates internal components, prevents cable pullout and saves time and labor. Listings: UL: Class I* Group A, B, C and D Class II* Group E, F and G Class III * Includes Division 1 and Division 2 Construction Suitable for industrial and commercial use. Manufactured from 6061 copper-free aluminum. A complete range of NPT (National Pipe Thread) sizes are available from 1/2" through 4". This accommodates armored cable type MC O.D. sizes from ". Copper AIA-PVC Part O.D. Range Copper AIA-PVC Part O.D. Range Copper AIA-PVC Part O.D. Range 14/2 AAP CONW /3 AAP CONW /04 AAP CONW /3 AAP CONW /4 AAP CONW /03 AAP CONW /4 AAP CONW /5 AAP CONW /04 AAP CONW /5 AAP CONW /7 AAP CONW /03 AAP CONW /7 AAP CONW /9 AAP CONW /04 AAP CONW /9 AAP CONW /19 AAP CONW /03 AAP CONW /12 AAP CONW /25 AAP CONW /04 AAP CONW /19 AAP CONW /37 AAP CONW /3 AAP CONW /25 AAP CONW /3 AAP CONW /4 AAP CONW /37 AAP CONW /4 AAP CONW /3 AAP CONW /2 AAP CONW /3 AAP CONW /4 AAP CONW /3 AAP CONW /4 AAP CONW /3 AAP CONW /4 AAP CONW /3 AAP CONW /4 AAP CONW /5 AAP CONW /4 AAP CONW /3 AAP CONW /7 AAP CONW /3 AAP CONW /4 AAP CONW /9 AAP CONW /4 AAP CONW /3 AAP CONW /12 AAP CONW /3 AAP CONW /4 AAP CONW /19 AAP CONW /4 AAP CONW /3 AAP CONW /25 AAP CONW /3 AAP CONW /4 AAP CONW /37 AAP CONW /4 AAP CONW /3 AAP CONW /2 AAP CONW /03 AAP CONW /4 AAP CONW

68 Armored Cable Available with tinned conductors. Conductors are stranded annealed copper, insulated with 30 mils, with heat and moisture resistant cross-linked polyethylene (Type XHHW-2), phase identified, and cabled together with a **bare copper ground conductor. Cable core is covered with binder tape, aluminum or galvanized steel interlocked armor, with an overall flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero Lead jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 Manufacturing quality. Delivering service. Jacketed MC XHHW-2/EnviroPlus Factory Mutual Group 1 listed Zero Halogen, Limited Smoke UL1569 Flame Rated: IEEE 1202/CSA FT-4 IEEE 383, UL 1685, UL 1581 Sunlight Resistant for CT use; Direct Burial 1 Temperature Rating: 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code: K-2 (Other colors available upon request) Zero Halogen, Limited Smoke Jacket -40 C Rated 68 #10 #12 #14 Part of Conductors Grounding Conductors () over Armor Jacket Approximate Net Weight Per 1000 (lbs) 30 C Ambient 90 C Wet / Dry AANH14/ AANH14/ AANH14/ AANH14/ AANH14/ AANH14/ AANH14/ AANH14/ AANH14/ , AANH12/ AANH12/ AANH12/ AANH12/ AANH12/ AANH12/ AANH12/ AANH12/ AANH12/ , AANH10/ AANH10/ AANH10/ AANH10/ AANH10/ AANH10/ AANH10/ AANH10/ AANH10/ , *Per NEC Table (Ampacity derated in accordance with note 8a) Includes encasement in concrete. The overcurrent protection shall not exceed 15 amps for 14, 20 amps for 12, and 30 amps for 10 per NEC footnote. ** Cable with 7 conductors or more shall have a green insulated ground. NOTE: Drawing is for illustration purposes only. The data shown is approximate and subject to standard industry tolerances.

69 1-ONE 2-TWO Available with tinned conductors. 3 or 4 conductors, stranded copper, insulated with heat and moisture resistant cross-linked polyethylene (Type XHHW-2), phase identified, cabled together with suitable fillers and bare copper ground conductor(s). (2 grounds/4 conductors) Cable core is covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero Lead Jacket. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 Manufacturing quality. Delivering service. Jacketed MC XHHW-2/EnviroPlus Factory Mutual Group 1 listed Zero Halogen, Limited Smoke UL1569 Flame Rated: IEEE 1202/CSA FT-4 IEEE 383, UL 1685, UL 1581 Sunlight resistant for CT use; Direct Burial 1 Temperature Rating: 90 C Wet/Dry ICEA S /NEMA WC-70 Color Code K-2 (Other colors available upon request) Zero Halogen, Limited Smoke Jacket -40 C Rated Armored Cable THREE CONDUCTOR FOUR CONDUCTOR Part or MCM Copper Grounding Conductors () over Armor (inch Jacket Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (30 C Ambient Wet/Dry) 90 C AANH8/ # AANH6/ # AANH4/ # AANH3/ # , AANH2/ # ,035 1, AANH1/ # ,252 1, AANH1/03 1/ # ,525 1, AANH2/03 2/ # ,825 2, AANH3/03 3/ # ,771 2, AANH4/03 4/ # ,741 3, AANH250/ # ,321 3, AANH350/ # ,444 4, AANH500/ # ,161 6, AANH600/ # ,331 7, AANH750/ # ,988 9, AANH8/ # AANH6/ # AANH4/ # , AANH3/ # ,093 1, AANH2/ # ,296 1, AANH1/ # ,609 1, AANH1/04 1/ # ,925 2, AANH2/04 2/ # ,355 2, AANH3/04 3/ # ,888 3, AANH4/04 4/ # ,501 3, AANH250/ # ,238 4, AANH350/ # ,770 6, AANH500/ # ,924 8, AANH600/ # ,458 10, AANH750/ # ,659 12, *Per NEC Table Includes encasement in concrete. **Fillers used when required. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 69

70 Armored Cable Manufacturing quality. Delivering service. Teck90 ServiceTeck Jacketed MC XHHW-2/PVC Class B stranded copper, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled with **bare copper ground conductor. Cable core covered with binder tape, an inner PVC jacket, aluminum interlocked armor and an outer PVC jacket. Features: Teck cable is suitable for use in exposed or concealed wiring in dry or wet locations, in ventilated or ladder type cable trays in dry or wet conditions, on walls or beams, or directly buried. Suitable for use in NEC Hazardous locations: Class I Groups A, B, C and D; Class II Groups E, F and G; Class III All Groups UL 1569 C(UL) Teck 90:CSA/UL Listed Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU), / FT4 IEEE 1202/CSA FT-4 Two-hour Firewall rated Sunlight Resistant for CT Use; Direct Burial 1, Oil Resistant II Jacket Color Code K-2/other color codes available Temperature rating at 90 C Wet/Dry ICEA S /NEMA WC-70 #10 #12 #14 Part of Conductors Grounding Conductors () PVC Jacket Approximate Net Weight Inner Outer Inner Jacket Armor Per 1000 (lbs) (30 C Ambient Wet/Dry) 90 C PAAP14/ PAAP14/ PAAP14/ PAAP14/ PAAP14/ PAAP14/ PAAP14/ PAAP14/ PAAP12/ PAAP12/ PAAP12/ PAAP12/ PAAP12/ PAAP12/ PAAP12/ PAAP12/ PAAP10/ PAAP10/ PAAP10/ PAAP10/ PAAP10/ PAAP10/ PAAP10/ PAAP10/ *Per NEC - Table Includes encasement in concrete. ** Cable with 7 conductors or more shall have a green insulated ground. Fillers used when required. NOTE: The data shown is approximate and subject to standard industry tolerances

71 1-ONE 2-TWO ed copper, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled with bare copper ground conductor(s). Cable core covered with binder tape, an inner PVC jacket, aluminum interlocked armor and an outer PVC jacket. Features: Teck cable is suitable for use in exposed or concealed wiring in dry or wet locations, in ventilated or ladder type cable trays in dry or wet conditions, on walls or beams, directly buried. Suitable for use in NEC Hazardous locations: Class I Groups A, B, C and D; Class II Groups E, F and G; Class III All Groups Manufacturing quality. Delivering service. Teck90 ServiceTeck Jacketed MC XHHW-2/PVC UL 1569 C(UL) Teck 90:CSA/UL Listed Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant for CT Use; Direct Burial 1, Oil Resistant II Jacket Color Code Black and ed/other color codes available Temperature rating at 90 C Wet/Dry ICEA S /NEMA WC-70 Armored Cable THREE CONDUCTOR Part or MCM Copper Grounding Conductors () PVC Jacket Inner Jacket Net Wt. per 1000 ft. (lbs.) 90 C PAAP8/ # PAAP6/ # PAAP4/ # PAAP3/ # , PAAP2/ # , PAAP1/ # , PAAP1/03 1/ # , PAAP2/03 2/ # , PAAP3/03 3/ # , PAAP4/03 4/ # , PAAP250/ # , PAAP350/ # , PAAP500/ # , PAAP600/ # , PAAP750/ # , Armor FOUR CONDUCTOR PAAP8/ # PAAP6/ # PAAP4/ # , PAAP3/ # , PAAP2/ # , PAAP1/ # , PAAP1/04 1/ # , PAAP2/04 2/ # , PAAP3/04 3/ # , PAAP4/04 4/ # , PAAP250/ # , PAAP350/ # , PAAP500/ # , PAAP600/ # , PAAP750/ # , * Per NEC Includes encasement in concrete. ** Fillers used when required. NOTE: The data shown is approximate and subject to standard industry tolerances NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 71

72 Armored Cable Manufacturing quality. Delivering service. Teck90 Jacketed MC Connectors For ServiceTeck Description & Features: These U.L. listed connectors are a one-piece body construction with a unique scroll design that can provide a 360 degree ground to armor. This connector provides a fast and easy installation, eliminates internal components, prevents cable pullout and saves time and labor. Listings: UL: Class I* Group A, B, C and D Class II* Group E, F and G Class III * Includes Division 1 and Division 2 Construction Suitable for industrial and commercial use. Manufactured from 6061 copper-free aluminum. A complete range of NPT (National Pipe Thread) sizes are available from 1/2" through 4". This accommodates armored cable type MC O.D. sizes from ". Item over Armor Water Tight Connector Item over Armor Water Tight Connector Item over Armor Water Tight Connector PAAP14/ CONW62 PAAP10/ CONW83 PAAP500/ CONW257 PAAP14/ CONW69 PAAP10/ CONW83 PAAP600/ CONW285 PAAP14/ CONW69 PAAP10/ CONW97 PAAP750/ CONW313 PAAP14/ CONW76 PAAP10/ CONW104 PAAP8/ CONW97 PAAP14/ CONW83 PAAP10/ CONW111 PAAP6/ CONW104 PAAP14/ CONW90 PAAP10/ CONW132 PAAP4/ CONW118 PAAP14/ CONW897 PAAP8/ CONW90 PAAP2/ CONW125 PAAP14/ CONW104 PAAP6/ CONW97 PAAP2/ CONW139 PAAP12/ CONW69 PAAP4/ CONW104 PAAP1/ CONW148 PAAP12/ CONW69 PAAP2/ CONW111 PAAP1/ CONW157 PAAP12/ CONW76 PAAP1/ CONW139 PAAP2/ CONW166 PAAP12/ CONW76 PAAP1/ CONW148 PAAP3/ CONW184 PAAP12/ CONW90 PAAP2/ CONW157 PAAP4/ CONW202 PAAP12/ CONW97 PAAP3/ CONW166 PAAP250/ CONW224 PAAP12/ CONW104 PAAP4/ CONW175 PAAP350/ CONW246 PAAP12/ CONW118 PAAP250/ CONW202 PAAP500/ CONW285 PAAP10/ CONW76 PAAP350/ CONW22 PAAP600/ CONW PAAP10/ CONW76 PAAP750/ CONW328

73 1-ONE 2-TWO Jacketed MC Manufacturing quality. Delivering service. RHW-2/PVC 2,000 Volt Copper Armored Cable 3 Conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and bare copper grounding conductor. Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame, oil and sunlight resistant black PVC jacket. Jacket available under armor and in colors. Available with EnviroPlus jacket. Application: Service Wire s 2000 Volt Interlocked Armor Cables are designed for use in industrial power distribution systems where continuity of service is the prime consideration. These cables may be installed in wet or dry locations, directly buried or embedded in concrete. Cables are also suitable for use in cable tray. ICEA S / NEMA WC-70 UL 44 UL 854 UL 1569 Features: Temperature rating 90 C Wet /Dry Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant for CT Use; Direct Burial 1, Oil Resistant II Jacket Excellent mechanical protection Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 Part or MCM Copper Grounding Conductors () over Armor (inch Jacket Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (30 C Ambient) AAP2K6/ AAP2K4/ AAP2K2/ ,202 1, THREE CONDUCTOR AAP2K1/ ,448 1, AAP2K1/03 1/ ,704 1, AAP2K2/03 2/ ,096 2, AAP2K3/03 3/ ,487 2, AAP2K4/03 4/ ,966 3, AAP2K250/ ,640 4, AAP2K350/ ,869 5, AAP2K500/ ,564 7, AAP2K750/ ,536 10, *Per NEC Table Includes encasement in concrete. 73

74 Armored Cable 1-ONE 2-TWO Jacketed MC Manufacturing quality. Delivering service. RHW-2/PVC 2,000 Volt Copper 4 Conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and bare copper grounding conductor(s). Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame, oil and sunlight resistant black PVC jacket. Jacket available under armor and in colors. Available with EnviroPlus jacket. Application: Service Wire s 2000 Volt Interlocked Armor Cables are designed for use in industrial power distribution systems where continuity of service is the prime consideration. These cables may be installed in wet or dry locations, directly buried or embedded in concrete. Cables are also suitable for use in cable tray. ICEA S / NEMA WC-70 UL 44 UL 854 UL 1569 Features: Temperature rating 90 C Wet /Dry Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Two-hour Firewall rated, (2/0 and smaller) Sunlight Resistant for CT Use; Direct Burial 1, Oil Resistant II Jacket Excellent mechanical protection Suitable for use in NEC Hazardous locations: Class I, Div. 2; Class II, Div. 2 Part or MCM Copper Grounding Conductors () over Armor (inch PVC Jacket Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (30 C Ambient) AAP2K6/ AAP2K4/ ,057 1, AAP2K2/ ,494 1, FOUR CONDUCTOR AAP2K1/ ,855 2, AAP2K1/04 1/ ,194 2, AAP2K2/04 2/ ,651 2, AAP2K3/04 3/ ,160 3, AAP2K4/04 4/ ,794 4, AAP2K250/ ,646 5, AAP2K350/ ,228 6, AAP2K500/ ,463 9, AAP2K750/ ,308 13, *Per NEC Table Includes encasement in concrete. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity.

75 MV-90/MV-105 Jacketed MC Nonshielded/Shielded, EPR 2,400/5,000 Volt Copper Armored Cable Nonshielded: Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant ethylene propylene rubber (2,400 Volt rated). Shielded: Class B stranded copper, extruded semi-conductor shield, insulated with heat and moisture resistant EPR, 133% insulation level, with overall jacket. 3 conductors cabled together with suitable fillers** and bare copper ground conductor. Cable core covered with binder tape, aluminum or galvanized interlocked armor, with flame and sunlight resistant yellow PVC jacket. Jacket available under armor and in colors. UL 1072 Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Class 1 Div II Sunlight Resistant for CT Use; Direct Burial 1, Oil Resistant II Jacket Color Code: K-2 Stripes Conductors rated at 105 C (5kV) / 90 C (2.4kV) Non-shielded: ICEA S /NEMA WC-71 Shielded: ICEA S /NEMA WC-74 Part or MCM Conductor Jacket Copper Grounding Conductor(s) () over Armor PVC Jacket Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (40 C Ambient) NON-SHIELDED AP2.4K6/3E ,234 1, AP2.4K4/3E ,463 1, AP2.4K2/3E ,795 2, AP2.4K1/3E ,076 2, AP2.4K1/03E 1/ ,345 2, AP2.4K2/03E 2/ ,693 3, AP2.4K4/03E 4/ ,015 4, AP2.4K250/3E ,769 5, AP2.4K350/3E ,017 6, AP2.4K500/3E ,881 8, AP2.4K750/3E / ,594 12, SHIELDED AP5KS6/3E ,478 1, AP5KS4/3E ,765 2, AP5KS2/3E ,085 2, AP5KS1/3E ,889 2, AP5KS1/03E 1/ ,898 3, AP5KS2/03E 2/ ,268 3, AP5KS4/03E 4/ ,255 4, AP5KS250/3E ,075 5, AP5KS350/3E ,326 6, AP5KS500/3E ,650 9, AP5KS750/3E / ,827 12, * Per NEC Table Based on one three-conductor cable. 1 Includes encasement in concrete. **Fillers used when required. 75

76 Armored Cable Manufacturing quality. Delivering service. MV-105/Jacketed MC 133% Jacketed EPR 15,000 Volt Copper Class B stranded copper, extruded semi-conductor shield, insulated with heat and moisture resistant EPR, 133% insulation level, with overall jacket. Cabled together with suitable fillers** and bare copper ground conductor. Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant red PVC jacket. Jacket available under armor and in colors. UL 1072 Flame Rated: IEEE-383 (70,000 BTU) ICEA T (210,000 BTU) IEEE 1202/CSA FT-4 Class 1 Div II Sunlight Resistant for CT Use; Direct Burial 1, Oil Resistant II Jacket Color Code: K-2 Stripes Conductors rated at 105 C ICEA S /NEMA WC-74 Part or MCM Conductor Jacket Copper Grounding Conductor(s) () over Armor PVC Jacket Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor (40 C Ambient) 133% EPR INSULATION AP15K2/3E ,987 3, AP15K1/3E ,298 3, AP15K1/03E 1/ ,674 4, AP15K2/03E 2/ ,083 4, AP15K4/03E 4/ ,100 5, AP15K250/3E ,180 6, AP15K350/3E ,507 8, AP15K500/3E ,878 10, AP15K750/3E / ,610 14, *Per NEC Table Based on one three-conductor cable. Includes encasement in concrete. **Fillers used when required. 76

77 Description & Features: General purpose UL listed Type THW Twisted, unjacketed, submersible pump cable features solid or stranded copper conductors individually insulated with a tough Type THW (PVC) compound. UL listed as Type THW-Twisted Submersible Pump cable Rated 75 C Oil and grease resistant conductors Applications: For use within the well casing to supply power to the submersible pump THW/Submersible Pump Cable Twisted Specifications & UL 83; UL1581; Construction: Conductors: Solid or stranded soft annealed copper : Thermoplastic PVC Color coding: black, red, yellow, green (ground) Assembly: The individually insulated conductors are twisted with a green insulated grounding conductor (sized in accordance with Table of the NEC) Temperature: 75 C Voltage: 600 Pump and Irrigation TWO OR THREE CONDUCTORS WITH GREEN INSULATED GROUNDING CONDUCTOR Part Conductor, Dimensions (inches) Power Ground O.D. Standard Packaging Ampacity NEC Weight (Lbs./Mft.) PT14/2GG 14/2 (solid) 14 (solid) & PT12/2GG 12/2 (solid) 12 (solid) & PT10/2GG 10/2 (solid) 10 (solid) & PT14/3GG 14/3 (solid) 14 (solid) & PT12/3GG 12/3 (solid) 12 (solid) & PT10/3GG 10/3 (solid) 10 (solid) & PT8/3GG 8/3 (7 str) 10 (7 str) & PT6/3GG 6/3 (19 str) 8 (19 str) & PT4/3GG 4/3 (19 str) 8 (19 str) & Per Table of the NEC #2 through 4/0 Twisted Unjacketed available upon request. All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. All sales are subject to Standard Terms & Conditions of Sale. 77

78 Pump and Irrigation Description & Features: UL listed Type THW twisted submersible pump cable is a multipurpose cable with individually insulated color coded conductors, green insulated ground (optional) and an overall jacket. Construction provides copper stranding insulated with a (PVC) compound. A tough PVC jacket is easily stripped to facilitate installation yet provide optimum flexibility, mechanical protection and crush resistance. UL listed as Type THW Submersible Pump cable Oil and grease resistant conductors Acid, alkali, oil and grease resistant jacket Weather, ozone and sunlight resistant jacket Abrasion and crush resistant Sequential Footage Marks Applications: For use within the well casing to supply power to the submersible pump Designed for use where extra mechanical protection during installation and operation are required THW/Submersible Pump Cable Round Jacketed Specifications & UL 83; UL1581; Construction: Conductors: ed soft annealed copper : Thermoplastic PVC Color coding: black, red, yellow, green (ground) Assembly: The insulated conductors, including the green grounding conductor, are cabled. Jacket: Black thermoplastic PVC Temperature: 75 C Voltage: 600 THREE CONDUCTORS WITH NO GROUND Part Conductor, Dimensions (inches) Power Ground Jacket O.D. Standard Packaging Ampacity NEC Weight (Lbs./Mft.) PTJ12/3 12 (19str) & 1, PTJ10/3 10 (19str) & 1, PTJ8/3 8 (19str) & 1, PTJ6/3 6 (19str) & 1, PTJ4/3 4 (19str) & 1, THREE CONDUCTORS WITH GROUND PTJ12/3GG 12 (19str) 12 (19str) & 1, PTJ10/3GG 10 (19str) 10 (19str) & 1, PTJ8/3GG 8 (19str) 10 (19str) & 1, PTJ6/3GG 6 (19str) 8 (19str) & 1, PTJ4/3GG 4 (19str) 8 (19str) & 1, PTJ2/3GG 2 (19str) 6 (19str) & 1, Per Table of the NEC #1 through 4/0 round jacketed pump available upon request. NOTE: Direct burial rated upon request. All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. All sales are subject to Standard Terms & Conditions of Sale. 78

79 Description & Features: UL listed Type THW general purpose flat rainbow submersible pump cable. Copper stranding covered with a tough PVC insulation applied directly over the conductors. Conductors are bonded together to assure easy separation, which facilitates installation, yet provides flexibility and mechanical protection. UL listed as Type THW Submersible Pump cable Oil and grease resistant Abrasion resistant Sequential footage marks Applications: For use within the well casing to supply power to the submersible pump Designed for use where flexibility during installation and operation are required THW/Rainbow Wire Submersible Pump Cable Flat with Ground Specifications & UL 83; UL1581; Construction: Conductors: ed soft annealed copper /Assembly: Insulated conductors, including the grounding conductor, are configured flat and parallel. Conductors are bonded together with no overall jacket. Conductors are solid colors of Black, Red, Yellow, and Green Temperature: 75 C Voltage: 600 Pump and Irrigation TWO OR THREE CONDUCTORS WITH GROUND Part Conductor, Dimensions (inches) Power Ground O.D. Standard Packaging Ampacity NEC Weight (Lbs./Mft.) PRB12/2GG 12/2 (19 str) 12 (19 str) x & PRB10/2GG 10/2 (19 str) 10 (19 str) x & PRB8/2GG 8/2 (19 str) 10 (19 str) x & PRB12/3GG 12/3 (19 str) 12 (19 str) x & PRB10/3GG 10/3 (19 str) 10 (19 str) x & PRB8/3GG 8/3 (19 str) 10 (19 str) x & PRB6/3GG 6/3 (19 str) 8 (19 str) x & Per Table of the NEC All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. All sales are subject to Standard Terms & Conditions of Sale. 79

80 Pump and Irrigation Description & Features: UL listed Type THW heavy duty flat submersible pump cable is a multi-purpose cable with parallel, individually insulated, color coded conductors, green ground insulated conductor and an overall jacket. Construction provides flexible copper stranding insulated with Type THW (PVC) compound. A tough PVC jacket, with a non-penetrating web, is easily stripped to facilitate installation yet provide optimum flexibility, mechanical protection and crush resistance. UL listed as Type THW Submersible Pump Cable Acid, alkali, oil and grease resistant Weather, ozone and sunlight resistant jacket Abrasion and crush resistant Sequential footage marks Applications: For use within the well casing to supply power to the submersible pump Designed for use where extra mechanical protection and flexibility during installation and operation are required THW/Submersible Pump Cable Heavy Duty Flat Jacketed with Ground Specifications & UL Standard 83; Construction: Conductors: Flexible stranded soft annealed copper : Thermoplastic PVC Color coding: black, red, yellow, green (ground) Assembly: The insulated conductors, including the grounding conductor, are configured flat and parallel without fillers Jacket: Black thermoplastic PVC applied directly over the conductors with a non-penetrating web Temperature: 75 C Voltage: 600 THREE CONDUCTORS WITH GREEN INSULATED GROUNDING CONDUCTORS Part Conductor, Dimensions (inches) Power Ground Jacket O.D. Standard Packaging Ampacity NEC Weight (Lbs./Mft.) PFB14/3GG 14/3 (7 str) 14 (7 str) x & PFB12/3GG 12/3 (19 str) 12 (19 str) x & PFB10/3GG 10/3 (19 str) 10 (19 str) x & PFB8/3GG 8/3 (19 str) 10 (19 str) x & PFB6/3GG 6/3 (19 str) 8 (19 str) x & PFB4/3GG 4/3 (19 str) 8 (19 str) x & PFB2/3GG 2/3 (19 str) 6 (19 str) x & ,036 PFB1/03GG 1/03 (19 str) 6 (7 str) x Bulk 150 1,613 PFB2/03GG 2/03 (19 str) 6 (7 str) x Bulk 175 1,932 PFB3/03GG 3/03 (19 str) 4 (7 str) x Bulk 200 2,135 PFB4/03GG 4/03 (19 str) 4 (7 str) x Bulk 230 2,871 PFB250/3GG 250/3 (37 str) 4 (7 str) x Bulk 255 3,518 PFB350/3GG 350/3 (37 str) 3 (7 str) x Bulk 310 4,689 PFB500/3GG 500/3 (37 str) 2 (7 str) x Bulk 380 6,410 TWO CONDUCTORS WITH GREEN INSULATED GROUNDING CONDUCTORS PFB14/2GG 14/2 (7 str) 14 (7 str) x & PFB12/2GG 12/2 (19 str) 12 (19 str) x & PFB10/2GG 10/2 (19 str) 10 (19 str) x & PFB8/2GG 8/2 (19 str) 10 (19 str) x & Per Table of the NEC All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. * Direct Burial rated in sizes 12 through 500 KCMIL, upon request All sales are subject to Standard Terms & Conditions of Sale.

81 UF / Type TWU Description & Features: C(UL) listed Single Conductor Type UF/Type TWU is suitable for use as Sprinkler Irrigation Control Wire for general purpose lighting and power. Construction provides solid or stranded soft annealed copper conductor insulated with PVC that provides excellent abrasion, acid, chemical, oil and moisture resistance. UL listed Type UF 600 Volt (#14 thru 4/0 ) C(UL) Listed Type TWU 600 Volt (#14 thru 4/0 ) Direct burial rated Resistant to acids, alkali, grease and chemicals Abrasion, crush and moisture resistant Applications: Suitable for use as power and control conductors for irrigation systems For use in accordance per NEC Article 339 Specifications & UL 493; UL1581; Federal Spec AA-59544, CSA C22.2 No. 75 Construction: Conductors: Soft annealed copper Solid (18 to 8 ) ed (6 to 4/0 ) : Thermoplastic PVC Temperature: 60 C Voltage: 600 Volts Pump and Irrigation TYPE UF SINGLE CONDUCTOR Part Conductor Dimensions (inches) Standard Packaging Weight (Lbs./Mft.) O.D. 500' 1000' 2500' ULE18 18 (solid) X X 13 ULE16 16 (solid) X X 15 UF14 14 (solid) X X 27 UF12 12 (solid) X X 36 UF10 10 (solid) X 50 UF8 8 (solid) X 81 UF6 6 (7 str) X 121 UF4 4 (7 str) X 176 UF2 2 (7 str) X 261 UF1/0 1/0 (19 str) Bulk 408 UF2/0 2/0 (19 str) Bulk 502 UF4/0 4/0 (19 str) Bulk 763 * UL Listed - UNDERGROUND LOW ENERGY 150 VOLT CIRCUIT CABLE SUNLIGHT RESISTANT. All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. STANDARD COLORS RD WE BE GN YW OE BN BK PE GY PK TN Single cond. size 18 and 16 S S A A A A A S A A A A Single cond. size 14 S S S S S S S S S S S S Single cond. size 12 and 10 S S A S A A A S A A A A Single cond. size 8 and larger A A A A A A A A A A A A NOTE: S = Stock, A = Available All sales are subject to Standard Terms & Conditions of Sale. 81

82 Sprinkler Control Cable 30 Volt Copper Pump and Irrigation Description & Features: Multi-conductor sprinkler control cable is a general purpose irrigation system control cable. Polyethylene (PE) jacket provides excellent abrasion, acid, chemical, oil and moisture resistance. Moisture resistant insulation Suitable for Direct Burial use Resistant to acids, alkali, grease and chemicals Impact, abrasion, and crush resistant Applications: Suitable for use as control cable for commercial and residential irrigation systems Specifications & UL Listed; Construction: Conductors: Soft annealed solid copper : Colored PVC compound Assembly: Conductors are cabled and jacketed with black PE (nylon rip cord under jacket). Temperature: 60 C MULTI-CONDUCTOR SPRINKLER CONTROL CABLE/60 C Part Conductor (solid) Dimensions (inches) Standard Packaging No. Jacket O.D ' 2500' Weight (Lbs./Mft.) SPR18/ x.191 X X 18 SPR18/ X X X X 24 SPR18/ X X X X 31 SPR18/ X X X X X 38 SPR18/ X X X X 44 SPR18/ X X X X X 51 SPR18/ X X X X 57 SPR18/ X X X X 64 SPR18/ X X X X X 71 SPR18/ X X X X 84 SPR18/ X X X X 90 All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. RD WE BE GN YW OE BN BK PE GY PK TN DK BE Color Sequence All sales are subject to Standard Terms & Conditions of Sale. 82

83 Description & Features: Underground Low Energy circuit Cable (Landscape Lighting Wire) is a superior multi-purpose product. A tough integral insulation and jacket of PVC covers the conductors and provides excellent abrasion, crush, chemical, oil and moisture resistance. A Mid rip between conductors provides for easy splitting and stripping. UL listed Underground Low Energy Circuit Cable 30 Volts Direct Burial rated Extra flexible stranding Resistant to acids, alkalis, grease and chemicals Sunlight and Abrasion Resistant Application: Suitable for use in direct burial landscaping and lighting applications Underground Landscape Lighting Low Energy Circuit Cable 30 Volt Copper Specifications & UL 1493; Construction: Conductor: Soft annealed extra flexible stranded copper per ASTM B-174 (#16, 14, 12 and 10 ) and ASTM B-172 (#8 ) Assembly: Two conductors are configured flat and parallel. Black PVC is applied directly over the conductors. Conductors are identified with ridges on the surface of the insulation. Temperature: 60 C Voltage: 30 Pump and Irrigation LOW ENERGY CIRCUIT CABLE; UNDERGROUND LANDSCAPE LIGHTING WIRE 60 C/30V Part Conductor (solid) Dimensions (inches) No. O.D Standard Packaging Weight (Lbs./Mft.) ULE16/2 16/ x , 250, 500, 1, ULE14/2 14/ x , 250, 500, 1, ULE12/2 12/ x , 250, 500, 1, ULE10/2 10/ x , 250, 500, 1, ULE8/2 8/ x , 250, 500, 1, All values aall values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. All sales are subject to Standard Terms & Conditions of Sale. 83

84 Copper Plater Wire Pump and Irrigation Description & Features: Solid bare copper, soft, medium hard, or hard drawn. Packaged on convenient spools. Per ASTM B49 Highest Conductivity per unit area of all commercially available metals used to conduct electricity. Soft Drawn: Flexible; easily formed into place Medium Hard and Hard Drawn; higher tensile strengths, respectively; more difficult to form Easily welded and soldered Application: Used as a hanger in the electro-plating industry Specifications & Soft Drawn: Per ASTM B3 Medium Drawn: Per ASTM B2 Hard Drawn Per ASTM B1 Construction: Bare Copper PLATER WIRE/BARE COPPER Part Conductor Approximate Ft./lb. Standard Put-up Per Carton Standard Packaging Weight (Lbs./Mft.) PLATER24 24 Solid x 10 lb. Spools PLATER22 22 Solid x 10 lb. Spools PLATER20 20 Solid x 10 lb. Spools PLATER16 16 Solid x 10 lb. Spools PLATER14 14 Solid 81 2 x 25 lb. Spools PLATER12 12 Solid 51 2 x 25 lb. Spools PLATER10 10 Solid 32 2 x 25 lb. Spools PLATER8 8 Solid 20 2 x 25 lb. Spools PLATER6 6 Solid 13 2 x 25 lb. Spools PLATER4 4 Solid 8 2 x 25 lb. Spools PLATER2 2 Solid 5 2 x 25 lb. Spools All diameters are nominal values; all weights are product weights exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. All sales are subject to Standard Terms & Conditions of Sale. 84

85 Applications: Permitted for use underground including direct burial in earth as Feeder or Branch Circuit Cable where provided with overcurrent protection For use in interior wiring in wet, dry or corrosive locations under recognized wiring methods of the National Electrical Code (NEC) Acceptable to be installed as a Non-Metallic Sheathed Cable in accordance with NEC Article (4) Acceptable for use in accordance with NEC Articles 300-4(b) and 339 TWO CONDUCTORS WITH GROUND Underground Feeder Cable UF-B Specifications & UL Standard Thermoplastic-Insulated Underground Feeder and Branch Circuit Cables Temperature: 75 C Voltage: 600 Description & Features: Type UF-B Underground Feeder Cable s construction provides solid or stranded Type THHN/THWN conductors laid parallel with an uninsulated grounding conductor. An outer jacket of tough PVC, provides protection against mechanical damage, moisture, chemicals and corrosion. Grease and chemical resistant conductors Moisture, chemical and sunlight resistant jacket Pump and Irrigation Part Dimensions (inches) PVC Nylon O.D. Standard Packaging Ampacity NEC Weight lbs./mft. UFB14/2G 14 (sol) x Ctn, 500 Reel 1000 Reel UFB12/2G 12 (sol) x Ctn, 500 Reel 1000 Reel UFB10/2G 10 (sol) x Ctn, 500 Reel 1000 Reel UFB8/2G 8 (7 str) x Reel UFB6/2G 6 (7 str) x Reel THREE CONDUCTORS WITH GROUND UFB14/3G 14 (sol) x Ctn, 1000 Reel UFB12/3G 12 (sol) x Ctn, 1000 Reel UFB10/3G 10 (sol) x Ctn, 500 Reel 1000 Reel UFB8/3G8 8 (7 str) x Reel 1000 Reel UFB6/3G6 6 (7 str) x Reel All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. Per Table of the NEC. * Reduced ground wire. All sales are subject to Standard Terms & Conditions of Sale. 85

86 Copper Contact Wire (for Electrified Rail Systems) Applications: Trolley wire is used as an overhead power source for electric railroad locomotives, cranes, light rail transit systems and underground mining motor cars. ASTM B-47 ASTM B-116 Single conductor, solid copper, having a hard drawn temper, made in the configuration of: grooved figure 8, or figure 9. Contact Wire Part Nominal Conductor Inches Millimeters Circular Mils Area Square Inches Square MM Pounds Per 1,000 Ft. Weight Pounds Per Mile KG Per KM Tensile Strength (Minimum) Lbs. Per Square Inch KGF Per Sq. MM Ohms Per 1000 Ft. Resistance (68 F/20 C) Ohms Per Mi. Min. Breaking Strength Ohms Per KM Pounds Kilograms BGRV2/0CU 2/ , , , ,437 2,466 Grooved BGRV3/0CU 3/ , , , ,373 2,891 BGRV4/0CU 4/ , , , ,759 3,519 BGRV300CU 300 MCM , ,792 1,350 44, ,410 4,722 BGRV350CU 350 MCM , ,613 1,582 42, ,810 5,357 BFIG81/0CU 1/0.420x x , , , ,296 1,949 FIGURE 8 BFIG82/0CU 2/0.480x x , , , ,248 2,380 BFIG83/0CU 3/0.510x x , , , ,392 2,899 BFIG84/0CU 4/0.600x x , , , ,744 3,513 BFIG8350CU 350 MCM.754x x , ,595 1,577 42, ,770 5,339 FIG. 9 BFIG9350CU 350 MCM.707x x , ,576 1,571 42, ,730 5,321 BFIG9400CU 400 MCM.715x x , ,348 1,789 41, ,880 5,842 86

87 Bronze Contact Wire (for Electrified Rail Systems) Applications: Trolley wire is used as an overhead power source for electric railroad locomotives, cranes, light rail transit systems and underground mining motor cars. ASTM B-9 Single conductor, solid bronze, having a hard drawn temper, made in the configuration of: grooved or figure 9. Part Nominal Conductor Inches Millimeters Circular Mils Area Square Inches Square MM Pounds Per 1,000 Ft. Weight Pounds Per Mile KG Per KM Tensile Strength (Minimum) Lbs. Per Square Inch KGF Per Sq. MM Ohms Per 1000 Ft. Resistance (68 F/20 C) Ohms Per Mi. Min. Breaking Strength Ohms Per KM Pounds Kilograms Contact Wire BGRV2/0-55 2/ , , , ,906 3,586 Grooved ALLOY 55 BGRV3/0-55 3/ , , , ,329 4,232 BGRV4/0-55 4/ , , , ,490 5,212 BGRV MCM , ,792 1,350 64, ,260 6,922 BGRV MCM , ,613 1,582 62, ,240 7,820 BGRV2/0-80 2/ , , , ,473 3,390 GROOVED ALLOY 80 BGRV3/0-80 3/ , , , ,804 3,993 BGRV4/0-80 4/ , , , ,820 4,908 BGRV MCM , ,792 1,350 61, ,480 6,568 BGRV MCM , ,613 1,582 59, ,410 7,414 FIG BFIG MCM.680x x , ,377 1,515 61, ,250 7,371 BFIG MCM.680x x , ,377 1,515 56, ,010 6,809 87

88 Messengers For Aerial Cable COPPERWELD - EHS, 30% CONDUCTIVITY MES(size)CUWELD O.D. ing Breaking Strength Wgt./Mft. MES1/4CUWELD 1/4" #12 5,783 lbs. 128 MES5/16CUWELD 5/16" # 10 9,196 lbs. 204 MES3/8CUWELD 3/8" # 8 13,890 lbs. 324 MES1/2CUWELD 1/2" # 6 20,460 lbs. 515 MES9/16CUWELD 9/16" # 5 24,650 lbs. 650 GALVANIZED - EHS MES(size)EHSGAL O.D. ing Breaking Strength Wgt./Mft. MES1/4EHSGAL 1/4" # 12 6,650 lbs. 121 MES5/16EHSGAL 5/16" # 10 11,200 lbs. 205 MES3/8EHSGAL 3/8" # 8 15,400 lbs. 273 MES1/2EHSGAL 1/2" # 6 26,900 lbs. 517 STAINLESS STEEL - TYPE 302 MES(size)SS O.D. ing Breaking Strength Wgt./Mft. MES1/4SS 1/4" # 12 8,500 lbs. 135 MES3/8SS 3/8" # 8 18,000 lbs. 282 MES1/2SS 1/2" # 6 33,700 lbs Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information.

89 ICEA Method 1 Table E-1 ("K1") (Colored Compounds with Stripes) Conductor Conductor Color Common Color Codes Stripe Color 1 Black - 2 White - 3 Red - 4 Green - 5 Orange - 6 Blue - 7 White Black 8 Red Black 9 Green Black 10 Orange Black 11 Blue Black 12 Black White 13 Red White 14 Green White 15 Blue White 16 Black Red 17 White Red 18 Orange Red 19 Blue Red 20 Red Green 21 Orange Green Conductor ICEA Method 4 (Black Compound with s) Manufacturing quality. Delivering service. ICEA Method 1 Table E-2 ( K2 ) (Colored Compounds with Stripes) Conductor Color Stripe Color 1 Black - 2 Red - 3 Blue - 4 Orange - 5 Yellow - 6 Brown - 7 Red Black 8 Blue Black 9 Orange Black 10 Yellow Black 11 Brown Black 12 Black Red 13 Blue Red 14 Orange Red 15 Yellow Red 16 Brown Red 17 Black Blue 18 Red Blue 19 Orange Blue 20 Yellow Blue 21 Brown Blue Conductor Printing Conductor Printing 1 1-One Twelve 2 2-Two Thirteen 3 3-Three Fourteen 4 4-Four Fifteen 5 5-Five Sixteen 6 6-Six Seventeen 7 7-Seven Eighteen 8 8-Eight Nineteen 9 9-Nine Twenty Ten Twenty-One Eleven Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information. 89

90 Minimum Bending Radii for Cables This section contains the minimum values for the radii to which cables may be bent for permanent training during installation. These limits do not apply to conduit bends, sheaves, or other curved surfaces around which the cable may be pulled under tension while being installed. Larger radii bends are required for such conditions. The minimum radii specified refers to the inner surface of the cable and not to the axis of the conductor. POWER & CONTROL CABLES WITHOUT METALLIC SHIELDING OR ARMOR of Cable (Inches) (Inches) 1.000" & less 1.001" " 2.001" & over MINIMUM BENDING RADIUS AS A MULTIPLE OF CABLE DIAMETER.169" & less POWER & CONTROL CABLES WITH METALLIC SHIELDING &/OR ARMOR Cable Description Minimum Bending Radius as a Multiple of Cable Interlocked Armor (with non-shielded cond.) Metallic Tape Shielded (conductors or cable) 7 12/7 (1) (1) 12 x individual shielded conductor diameter, or 7 x overall cable diameter, whichever is greater Above tables per ICEA S /NEMA WC70, Appendix F Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information. 90

91 Maximum Pulling Tensions 1. Pulling Eye Maximum pulling tension for use with a pulling eye can be determined from the following formula: Tmax = k x n x CA Where: k =.008 for copper.006 for aluminum n = number of conductors CA = conductor area of one conductor, in circular mils Tmax should not exceed 6,000 lb. for a single conductor cable. Tmax should not exceed 10,000 lb. for 2 or more conductors. 2. Pulling Grip Maximum pulling tension when using a basket type grip should not exceed 1,000 lb. or the value determined in the above formula, whichever is smaller. NOTE 1: Do not exceed the load stated by the manufacturer of the pulling device. NOTE 2: Do not consider the area of neutral or grounding conductors in cable(s) when calculating maximum pulling tensions. NOTE 3: Pulling tensions should be reduced by 20% to 40% when several conductors are being pulled simultaneously (in parallel) since the tension will not be distributed evenly among conductors. NOTE 4: The above procedure pertains to straight pulls, and does not consider side wall loading. Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information. 91

92 Maximum Cable per Sheave Sheave diameter (inches) Single/multi Conductor power (inches) Sheave Selection Chart Control Cable (inches) Shielded 600 V Power (inches) MV Power Shielded (inches) Armor (inches) Examples of Minimum Bend Radii 600 V Cable Multiply Sample diameter Calcuation Resulting Minimum Bend Radii Less than 1 inch 4.75 in. OD 4 x.75= 3 in. radius 1 to 2 inches in. OD 5 x 1.5= 7.5 in. radius 2 in. or larger in. OD 6 x 3= 18 in. radius Interlock Armor in. OD 7 x 3= 21 in. radius Pull considerations: 1. Plan direction of cable pulls to minimize tension by putting as many bends as possible early in the pull. 2. Proper setups cost initially, but will save by creating safer and easier pulls. 3. Published allowable conductor tensions are for STRAIGHT PULLS ONLY. 4. Published allowable equipment loading does not apply to the SWP of the cable pull. Notes: 1.) You must select the sheave by radius NOT diameter. 2.) Sidewall limits for most cables are 500 lbs. per foot radius maximum. 3.) All tensions on a cable pull are additive. Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information. 92

93 Cable Installation Tips Sheave strength ratings are for straight pulls only. Always refer to allowable tensions for each radius. Most single and conveyor sheaves are rated at 4000 lbs or more, but these ratings can only be used for the pulling rope, not the cable. Single sheaves are best for guiding and supporting cable. For cable bends use conveyor sheave assemblies to control sidewall pressure. 24" 6" 18" 12" Cable damage can occur when too small of a radius wheel is used. NOTE: When using conveyor sheave equipment, it is critical for set up that the lead and exit sheaves not have a bending radius smaller than the center wheels. (see below left) Danger Too small! Don't confuse the diameter of the sheave with the radius. The radius MUST match the cable's bending radius Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information. 93

94 Cable Installation Tips Stringing Aerial cables on poles (this applies to pulling in or out) Wrong: This method can cause sidewall pressure and crush the cable. Right: Create a smooth radius with sheaves using temporary messengers and proper spacing. Anchor spud or Line truck This method will support and distribute all bearing loads for successful cable installation. Loading cable into tray Wrong: This method can cause sidewall pressure and crush the cable at the leading point. Lack of rollers will increase drag creating more tension. Right: Rollers Use a large multi-wheel conveyor to distribute sidewall pressure. Lead and exit wheels must meet minimum cable bend. Use tray rollers to eliminate cable drag. 94 Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information.

95 Tray Roller Assembly It is important that these assemblies be aligned and secure. Shifting of roller assemblies can cause the cable to climb over sheave edge and cut the cable. All rollers to be free rolling to eliminate friction. Space tray rollers to minimize cable drag. Use greater bending radii than allowed. Good but cable can drag Good for tray defection Better reduces cable drag Best with more elevation For cable loading and corners Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information. 95

96 USEFUL Useful CONVERSION Conversion Factors FACTORS to METRIC Manufacturing quality. Delivering service. DIAMETER MM 2 CMIL INCHES / / / / DIAMETER KCMIL MM 2 CMIL INCHES MISCELLANEOUS CONVERSIONS UNIT MULTIPLY BY TO GET Centimeters Inches Circular Mils Square Mils x10-4 Square Millimeters Cubic Centimeters Cubic Inches Cubic Inches Cubic Centimeters Inches 2.54 Centimeters Kilograms Pounds Kilograms/Kilometers Pounds/1000ft. Kilometers Miles Feet Meters Feet Mils Inches Millimeters Miles Kilometers Millimeters Inches Ohms/Kilometer Ohms/1000ft. Ohms/1000ft Ohms/Kilometer Pounds Kilograms Pounds/1000ft Kilograms/Kilometer Square Centimeters 1.55x10 5 Square Mils 1.97x10 5 Circular Mils Square Inches x10 6 Circular Mils Square Millimeter Square Millimeter Circular Mils All data and information in this section is based on information currently available and is believed to be reliable. Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information. Service Wire Company believes the information presented herein is, to the best of our knowledge, true and accurate based on currently available industry data. However no warranties, either expressed or implied, are made as to the accuracy or completeness of any information contained herein. Consequently, Service Wire Company makes no guarantee of the results and assumes no obligation or liability whatsoever in connection with this information www. Phoenix, AZ AZ Culloden, WV Culloden, Houston, WV TX Pittsburgh, Houston, PA TX

97 TERMS and CONDITIONS All sales of material by Service Wire Company are expressly conditioned upon the terms and conditions set forth below. Any additional or different terms or conditions set forth in the purchase order of the Purchaser or in any similar such communication are hereby objected to by Service Wire Company and shall not be binding nor effective unless assented to in writing by an officer of Service Wire Company. Terms and Conditions are subject to change without notice. PRICES Unless otherwise stated, all prices by Service Wire Company are subject to change without notice. Prices do not include sale, use, excise, value added or similar taxes and, where applicable, such taxes shall be as a separate item and paid by the Purchaser. Any deviation after placement of order such as changes in quantity or partial release or change in ship dates may increase price. DELIVERY Delivery commitments are based upon the best information present at time of quotation and/or time of order entry, but may change due to conditions beyond Service Wire Company s control. Service Wire shall have no liability whatsoever for failure to meet delivery or shipment schedules. Delivery must be within 30 days after receipt of order or manufacturing lead time. Extended requested delivery dates are subject to price revisions or cancellation of the order by Service Wire Company. Service Wire reserves the right to invoice buyer immediately if customer delays delivery. In addition after 30 days, storage charges will be charged to buyer at a minimum rate of one-half of one percent of the invoice amount per month. Buyer s order is accepted subject to Service Wire being able to obtain the necessary raw materials and subject to government priorities and other government regulations that may be issued from time to time. Availability of items quoted as stock are done so on a subject to prior sales basis. PAYMENT Each shipment shall be deemed to have been sold under a separate and independent contract. Payment is due and Payable thirty (30) days after invoice date unless otherwise specified. A finance charge of 1 ½% per month will be added to the unpaid balance on all accounts not paid in full on or before the due date. The finance charge is equivalent to an annual percentage rate of 18%. Time is of the essence and, in addition to any other rights, Service Wire shall further have the right, at its option, to terminate this agreement without notice to Buyer if payment is not made on or before the due date or if Buyer becomes insolvent, or if Buyer s ability to pay debts in the normal course of business otherwise becomes impaired. If, in the judgment of Service Wire, the financial condition of the Purchaser at the time of manufacture or shipment does not justify the terms or payment specified, Service Wire reserves the right to require full or partial payment before manufacture or shipment and to suspend any further performance until such payment has been received. QUANTITY VARIATION On all orders, quantities are subject to a quantity variation of plus or minus ten percent (10%) unless otherwise specified or agreed upon. RETURNED GOODS No credit will be allowed for goods returned without Service Wire s prior authorization, nor will Service Wire accept responsibility for return shipping costs. Buyer has a duty to inspect all materials upon receipt and failure to object in writing within seven (7) days of receipt shall constitute an irrevocable acceptance of the goods and a waiver of any and all claims relating to those goods. Merchandise cut to Buyer s measurements, or manufactured to Buyer s specifications, are non-cancelable and non-returnable. LIMITED WARRANTY All Service Wire products are carefully inspected, tested, and packed before shipment and are receipted for by carrier in first class condition. Should any goods or materials prove defective due to defects in manufacture within one (1) year from invoice date, upon written notice to Service Wire, such material shall be replaced F.O.B. original destination point. This guarantee covers the cost of replacement of the product only and does not include the cost for installation, shipping, and handling. In no event will Service Wire be liable to the purchaser or the ultimate user of its product or any other party, for any damages, including but not limited to, loss of profits, loss of use, cost to repair, replacement of damaged goods or property; or any other incidental or consequential damages arising out of the use of the product, even if Service Wire its agents or representatives, has been advised of the possibility of such damages. This warranty is expressly in lieu of all other warranties expressed or implied including the warranties for labor charges, or merchantability, and of fitness for a particular purpose, and shall be voided if any work or modification is performed on the product without factory authorization. This limited warranty represents the complete and exclusive agreement between Service Wire and Buyer concerning warranties of the product and supersedes any proposal or prior agreement, oral or written, and any communications between Service Wire and Buyer concerning the product. 97

98 CANCELLATION Orders for Product cut to Buyer s measurements or manufactured to Buyer s specifications may not be cancelled. All other orders may be cancelled by Purchaser based upon payment to Service Wire of reasonable and proper cancellation charges pursuant to Service Wire s pricing policy or as determined by mutual agreement. ASSIGNMENT Any assignment of any contract/order, or any right thereunder, by the Purchaser without the advance written consent of Service Wire shall be void. HAZARDOUS BUSINESS Service Wire s products are designed and manufactured for use in standard industrial and commercial applications. If our products are to be applied in any location which might be of a hazardous nature, such as atomic installations, commercial or military aircraft, missile installations, space explorations or other critical applications where a failure of a single component could cause substantial harm to persons or property, Service Wire disclaims all responsibility. Such concurrence must be signed by an officer of Service Wire Company. GENERAL TERMS Any of the terms and provisions of Buyer s order which are inconsistent with the terms and provisions hereof shall not be binding on Service Wire Company and shall not be considered applicable to the sale or shipment of the merchandise referred to herein. Unless Buyer shall notify Service Wire in writing to the contrary as soon as practicable after receipt of quotation by Buyer, acceptance of the terms and conditions hereof by Buyer shall be indicated, and, in the absence of such notification, the sale and shipment by Service Wire of the merchandise covered hereby shall be conclusively deemed to be subject to the terms and conditions herein. A standard, form purchase order or similar document shall not constitute written objection to the terms herein. Rather a written objection must be separately stated, and addressed to Attn: Credit Manager, Service Wire Company, 310 Davis Road, Culloden, WV 25510, and must state with particularity those specific terms to which Buyer objects. In the event this written notice is not timely sent, before shipment or delivery of the product, then Buyer waives any and all rights to object to the terms herein. ATTORNEY'S FEES, JURISDICTION AND VENUE Buyer agrees that in the event there is a dispute between Buyer and Service Wire, each party will pay their individual costs of such proceedings, including but not limited to attorney fees, court costs and other costs (including without limitation all expert witness or other fees incurred, and any and all costs charged by any law firm or attorney. Buyer agrees that any and all disputes with Service Wire, including not just contract but also tort claims, shall be resolved in the state or federal courts situated in Cabell County, West Virginia, and that these courts shall have the exclusive jurisdiction over all such disputes and Buyer consents to personal jurisdiction in these courts. Any legal action brought by Buyer against Seller shall be filed in the above referenced jurisdiction within one (1) year after the cause of action arises or it shall be deemed forever waived. INTELLECTUAL PROPERTY AND INDEMNIFICATION Service Wire Company makes no warranty or representation with regard to any patent, trademark, copyright, trade dress, or trade secret, relating to or claimed to arise from any product sold to Buyer. Service Wire will not and does not indemnify or otherwise hold harmless Buyer from any claim of misappropriation or infringement of any patent, trademark, trade dress, trade secret, copyright or other rights relating to any product. Buyer agrees that Buyer will not make any such claim, or seek any such indemnification, and that such a claim or demand by Buyer constitutes a breach of these Standard Terms, and that Buyer shall pay all attorney fees and other court costs incurred by Service Wire in defending against any such claim or demand, whether or not a legal action is commenced or filed. 98

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

100% EMI Emission Containment

100% EMI Emission Containment 100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive

More information

MANUFACTURER S CERTIFICATE OF COMPLIANCE

MANUFACTURER S CERTIFICATE OF COMPLIANCE s Type AC (Armored Clad) aluminum and steel interlocked metal clad 600-volt cable is produced 100% in the United States of America using accepted practices and quality assurance procedures to comply with

More information

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor TABLE OF CONTENTS SECTION I. SUBJECT SCOPE 2 II. APPLICABLE DOCUMENTS 2 III. CONDUCTOR 3 IV. SEPARATOR 3 V. INSULATION 3 A. 3-4 B. Electrical Properties 4 C. Flame Resistance 5 D. Smoke and Halogen Testing

More information

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED

More information

Your Only Solution for All Variable Frequency Drive Applications

Your Only Solution for All Variable Frequency Drive Applications ASD/VFD Cable System ASDBrochure.indd 1 Your Only Solution for All Variable Frequency Drive Applications 11/2/12 9:23 AM Inadequacies in Standard VFD Cables: EMC-Electro Magnetic Compatibility Electromagnetic

More information

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World

More information

MESSENGERS FOR AERIAL CABLE

MESSENGERS FOR AERIAL CABLE MESSENGERS FOR AERIAL CABLE COPPERWELD - EHS, 30% CONDUCTIVITY MES(size)CUWELD Size O.D. Stranding Breaking Strength Wgt./Mft. MES1/4CUWELD 1/4".242 7 #12 5,783 lbs. 128 MES5/16CUWELD 5/16".306 7 # 10

More information

Industrial Cable Solutions for Variable Frequency Drives

Industrial Cable Solutions for Variable Frequency Drives Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading

More information

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32

Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32 Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud

More information

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL* Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly

More information

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Introduction This document presents the fundamental aspects of cable and conductor selection for connecting pad mounted shunt

More information

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G

2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements

More information

W-2. Stranding Comparison

W-2. Stranding Comparison Wire Knowledge W-1 W-2 Stranding Comparison Conductor Coatings/Coverings PURPOSE To facilitate stripping of components applied over the conductor To prevent compound fall-in Improve solderability Prevent

More information

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders,

More information

STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum

More information

STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum

More information

Section 5 161 kv Power Cables

Section 5 161 kv Power Cables Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper

More information

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM

More information

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

The Contractor shall furnish and install all shielded power cable suitable for use on this project. Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS

More information

Building Cables and Wires

Building Cables and Wires Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for

More information

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES Introduction General Cable understands that assisted living facilities require complex building designs that must address a wide range of systems

More information

Uptown Campus, Primary Electric Master Plan - Program Study State University of New York At Albany, SUCF Project No. 01832 V.

Uptown Campus, Primary Electric Master Plan - Program Study State University of New York At Albany, SUCF Project No. 01832 V. V. DESIGN STANDARDS i. Medium Voltage Cables ii. iii. iv. Separable Connectors Splices & Fault Indicators Manholes & Ductbanks Primary Switches & Medium Voltage Transformers v. Metering, Monitoring, &

More information

Hook-Up and Lead Wire

Hook-Up and Lead Wire 3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:

More information

Outside Telephone Cable

Outside Telephone Cable Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of

More information

Exane 125 Drilling Rig and Commercial Marine Cable

Exane 125 Drilling Rig and Commercial Marine Cable Exane 125 Drilling Rig and Commercial Marine Cable Over 20 Years of Superior Perfomance On Oil Rigs Around The World Engineered Wire & Cable for Demanding Applications Certified as Type P per IEEE-45 STD

More information

All Wires and Cables Are Not Created Equal

All Wires and Cables Are Not Created Equal All Wires and Cables Are Not Created Equal When comparing life cycle costs for wires and cables in wind systems, consider the specific applications, cost per failure and dielectric losses to determine

More information

Installation and Application Guide. for 600V Conductors

Installation and Application Guide. for 600V Conductors for 600V Conductors for 600V Conductors Foreward This guide discusses recommended or best practices for installing 600 volt conductors in conduit. The purpose of the guide is to identify those critical

More information

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies Select, Customize, Order & Receive Products with Ease This catalog contains

More information

CONFLEX ELECTRIC CABLE

CONFLEX ELECTRIC CABLE CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard

More information

MEDIUM VOLTAGE POWER CABLES

MEDIUM VOLTAGE POWER CABLES MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM

More information

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE

More information

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com * 2012 CATALOG AEROSPACE VVIRE & CABLE INC. A VV aerospacewire.com W e p r o u d l y m a n u f a c t u r e h i - t e m p w i r e & c a b l e. PLENUM CABLE. INDUSTRIAL CABLE. TRAY CABLE. MILITARY WIRE.

More information

Communication, Signal & Data Cables

Communication, Signal & Data Cables Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication

More information

L O W - S M O K E, Z E R O - H A L O G E N C A B L E S :

L O W - S M O K E, Z E R O - H A L O G E N C A B L E S : L O W - S M O K E, Z E R O - H A L O G E N C A B L E S : B R I D G I N G T H E P E R F O R M A N C E G A P Next Generation Low-Smoke, Zero-Halogen (LSZH) Thermoset Insulation A Look at General Cable s

More information

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation.

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation. UNDERSTANDING UNDERSTANDING NFPA 79 By Ned Lloyd and Mike Levesque NFPA-79 is the electrical standard that has been developed by the National Fire Protection Association (NFPA) and is intended to minimize

More information

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE 2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying

More information

CCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S

CCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S CCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the

More information

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness

450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness 450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER

THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER Ever Wonder Why There s No Copper in the Air? Since the early 1900s, aluminum and aluminum

More information

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for

More information

DIRECTCONNECT SERVICE

DIRECTCONNECT SERVICE DIRECTCONNECT SERVICE PRE-ASSEMBLED: LEADS, GROUNDS AND STINGERS/WHIPS Save Time, Labor and Money Lead Stinger/Whip Stock Colors (Blue, Green, Red, Yellow) available Stocked genuine Lenco and Tweco Connectors

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

Solar Power Solutions

Solar Power Solutions Solar Power Solutions Wire and Cable Photovoltaic Connectors Combiner Boxes Fuses Grounding Power Connectors Physical Support Products Cable Ties Supply Chain Solutions Products. Technology. Services.

More information

ETHERLINE Ethernet Cable, Connectors & Tools

ETHERLINE Ethernet Cable, Connectors & Tools Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary

More information

Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.

Basic Cable Assemblies DELIVERING QUALITY SINCE 1952. Basic Cable Assemblies DELIVERING QUALITY SINCE 1952. Cable Types Cable Types Hook-up & Lead Wire Most Basic 2 Cable Types Cable Types Twisted Pair Cable A type of cable that consists of two independently

More information

Network Standard Advice No. 1420C 9/6/2011

Network Standard Advice No. 1420C 9/6/2011 Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT

More information

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable. EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex

More information

VIPERFLEX ELECTRIC CABLE

VIPERFLEX ELECTRIC CABLE VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables

More information

SECTION 18370 SIGNAL WIRE AND CABLE

SECTION 18370 SIGNAL WIRE AND CABLE SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory

More information

Servo Motor & Drive Cables

Servo Motor & Drive Cables Servo Motor & Drive Cables Servo-Motor & Drive Cable Contents Servo-SM (Servo-Motor & Feedback Cables to Siemens Specifications) 970 SERVO-SM5-6FX5008-1BD.. UL/CSA/CE SHLD PVC Feedback Cable- Green 971

More information

SECTION 260513 MEDIUM VOLTAGE CABLE

SECTION 260513 MEDIUM VOLTAGE CABLE SECTION 260513 MEDIUM VOLTAGE CABLE PART 1 - GENERAL 1.1 SUMMARY A. Related Documents: 1. Drawings and general provisions of the Subcontract apply to this Section. 2. Review these documents for coordination

More information

CHAPTER 2 EXAMPLES AND TABLES

CHAPTER 2 EXAMPLES AND TABLES CHAPTER 2 EXAMPLES AND TABLES COMMENTARY AT 210.20(A) EXCEPTION An overcurrent device that supplies continuous and noncontinuous loads must have a rating that is not less than the sum of 100 percent of

More information

RF & Microwave cable assemblies C291

RF & Microwave cable assemblies C291 ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible

More information

APPLICATION ORIENTED DESIGN OF CABLES

APPLICATION ORIENTED DESIGN OF CABLES APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

Contact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372

Contact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372 Hueson Corporation of Northbridge MA, a specialty wire and cable manufacturer has recently introduced a solution to a long term industry challenge in the Trailer Cable Industry. Their solution involves

More information

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc. CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation

More information

LOW VOLTAGE POWER CABLES

LOW VOLTAGE POWER CABLES LOW VOLTAGE POWER CABLES CONTENTS 1 4 GENERAL INTRODUCTION TECHNICAL BARE SOFT DRAWN STRANDED CONDUCTORS 38 39 44 48 52 53 56 59 60 63 68 72 75 76 79 82 83 INFORMATION COPPER PVC INSULATED PVC SHEATHED

More information

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER Large numbers of electrical engineers have limited detail knowledge concerning wiring systems. There is the tendency by engineers to avoid becoming involved in the details of wiring systems, leaving the

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS

More information

Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers 9229 Waterford Centre Dr. Bldg C, Suite 110 Austin, Tx 78758 Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers Current Version: 13 AC Modules are a new product

More information

ELECTRICAL: WIRE, CABLE, AND TERMINATIONS

ELECTRICAL: WIRE, CABLE, AND TERMINATIONS ELECTRICAL: WIRE, CABLE, AND TERMINATIONS BASIS OF DESIGN This section applies to the design and installation of wire and cable systems and terminations. Design Criteria Medium Voltage Review and modify

More information

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES Quality Reliability Innovation ISO : CERTIFIED BY AFAQ No. QUAL / 7 / 7 a COPPER TELECOMMUNICATION CABLES COPPER TELECOMMUNICATION CABLES CONTENTS 7 NOTICE INTRODUCTION QUALITY ASSURANCE RECOMMENDED ORDERING

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Recommended Practices for Designing and Installing Copper Building Wire Systems

Recommended Practices for Designing and Installing Copper Building Wire Systems Recommended Practices for Designing and Installing Copper Building Wire Systems CDA - CWIS Committee December 3, 2013 Developed by the Copper Development Association Inc. www.copper.org Foreword This document

More information

STREETLIGHT SYSTEM GROUNDING AND BONDING

STREETLIGHT SYSTEM GROUNDING AND BONDING Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial

More information

BASIC NEC CODE RULES AND DESIGN PRACTICE

BASIC NEC CODE RULES AND DESIGN PRACTICE BASIC NEC CODE RULES AND DESIGN PRACTICE Wire Ampacity and Size Circuit Breaker Size 1. Maximum loading for any branch circuit is 80% of rating of circuit for ampacity of wire for any load. NEC 220-2,

More information

600V Power Cable 600V SOOW SOW

600V Power Cable 600V SOOW SOW 600V Power Cable Type SOOW UL/CSA 90 C 600V Part AWG No of Insulation Jacket Nominal Wieght/Mft Number Stranding conductors Thickness Thickness O.D. Nom. 18 2 SOOW 18 AWG 2.30 71 18 3 SOOW 16/.010 3.030

More information

The MC Cable Revolution is Gaining Ground REMKE

The MC Cable Revolution is Gaining Ground REMKE The MC Cable Revolution is Gaining Ground June 2014 MC Cable Installation Continues to Improve with Advances in Materials and Fittings As the use of Metal Clad Cable grows, contractors are demanding better

More information

General Calculations. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

General Calculations. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE Excerpt from PRYMIAN WIRE AND CABLE ENGINEERING GUIDE Page 1 of 0 Voltage Rating The selection of the cable insulation level to be used in a particular installation shall be made on the basis of the applicable

More information

Electrical Code Regulation

Electrical Code Regulation Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county

More information

Voltage Drop (Single-Phase)

Voltage Drop (Single-Phase) Voltage Drop (Single-Phase) To Find: To Find Voltage Drop Formula: 2 x K x L x I V.D. = ------------------- C.M. Variables: C.M. = Circular Mill Area (Chapter 9, Table 8) To Find Voltage Drop Percentage

More information

MEDIUM VOLTAGE CABLES Up to and including 36 KV

MEDIUM VOLTAGE CABLES Up to and including 36 KV MEDIUM VOLTAGE CABLES Up to and including 6 KV NOTICE As this catalogue is not intendedto cover all of LIBAN CABLES SAL possibilities in special cables manufacturing, the hereafter listing of the types

More information

Tri-Rated Flexible PVC Equipment Wire

Tri-Rated Flexible PVC Equipment Wire Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier

More information

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS

More information

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

CABLE SPECIFICATION CAN CAB RJ45-SUBD9 CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector

More information

BRANCH CIRCUIT AND FEEDER REQUIREMENTS

BRANCH CIRCUIT AND FEEDER REQUIREMENTS CHAPTER 36 BRANCH CIRCUIT AND FEEDER REQUIREMENTS SECTION E3601 GENERAL E3601.1 Scope. This chapter covers branch circuits and feeders and specifies the minimum required branch circuits, the allowable

More information

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology ANACONDA SEALTITE ANAMET Electrical, Inc. AN ANAMET COMPANY When you say SEALTITE, there is only one: ANACONDA. Type MTC Type UA

More information

Technical Information Handbook

Technical Information Handbook Technical Information Handbook Wire and Cable Products. Technology. Services. Delivered Globally. We are a leading global supplier of communications and security products, electrical and electronic wire

More information

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,

More information

Conductor Sizing and the National Electrical Code

Conductor Sizing and the National Electrical Code Conductor Sizing and the National Electrical Code The National Electrical Code requirements for conductor sizing and overcurrent protection have always been confusing and complex. Factors that must be

More information

TELE-FONIKA CABLE AMERICAS

TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS (TF KABLE) is a US firm with corporate offices and main facility located in Bolingbrook, IL and is a wholly owned subsidiary of Tele-Fonika Kable SA.

More information

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the

More information

Uniprise Solutions COAX 101. White Paper. www.commscope.com

Uniprise Solutions COAX 101. White Paper. www.commscope.com Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems

More information

Specification SFTP CAT6 Network Cable 23AWG CU

Specification SFTP CAT6 Network Cable 23AWG CU Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)

More information

Product Catalog. Wire, Cable & Wire Management Solutions. go further with yourteam

Product Catalog. Wire, Cable & Wire Management Solutions. go further with yourteam Product Catalog Wire, Cable & Wire Management Solutions go further with yourteam About Us IEWC is a premier, dedicated supplier of wire, cable and wire management products for manufacturers and sub-assemblers

More information

Commercial Coaxial Cable

Commercial Coaxial Cable Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of

More information