ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology
|
|
|
- Bryan Porter
- 9 years ago
- Views:
Transcription
1 ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology ANACONDA SEALTITE
2 ANAMET Electrical, Inc. AN ANAMET COMPANY When you say SEALTITE, there is only one: ANACONDA. Type MTC Type UA Type CNP SHIELDTITE Type EF Index FLEXIBLE CONDUIT TYPES 4-5 EF 6 EFST 7 UA 8 RWS 9 RWA 10 CW 11 NMUA 12 HTUA 13 HC 14 HCX 15 XTHF 16 ZHUA 17 OR 18 EFL 19 MTC 20 CNP 21 FITTING SELECTION GUIDE 22 STAINLESS STEEL FITTINGS STAINLESS STEEL COMPACT FITTINGS 24 NPT COMPACT FITTINGS 25 METRIC COMPACT FITTINGS 26 STEEL FITTINGS 27 NON-METALLIC FITTINGS 28 DE DSL 30 SL 31 UI 32 FIRETECH 33 SHIELDTITE 34 SHIELDTITE Z1 35 NMFG 36 FG 37 NWC 38 FIXTURE WHIPS 39 CHEMICAL RESISTANCE CHART PART NUMBERS/PAGE REFERENCE PRODUCT COMPARISON CHART 44 PACKAGING & CUTTING INSTRUCTIONS 45 SPECIAL SERVICES/COMMITMENT 46 ABOUT ANAMET 47 2 CAT ANAMET Electrical, Inc.
3 ANAMET Electrical, Inc. AN ANAMET COMPANY ANAMET Advantage The Anamet Advantage is to ship all orders within two days or less. Same day shipping available. Cutoff time for freight shipments is 11am central time Cutoff time for small package (UPS or FedEx) is 2pm central time Percentage of Promises Kept Stock Orders 97.4% Special Orders 96.9% Kept Promise: Two business or less days from order date (request date for special orders) to ship date. (Excludes Saturdays and Sundays and major U.S. holidays) US Locations Anamet Electrical, Inc. has stocking warehouses throughout the US in all major metropolitan areas. ANAMET Electrical, Inc. CAT
4 Flexible Conduit Types Product Type Pg Application Certifications EF General 6 Hot Dipped Zinc Galvanized Steel Core Polyvinyl Chloride Cover Size Range: 3/8 thru 2 - Gray Designed for General Grade Applications Temperature Range: -4 F to +140 F (-20 C to +60 C) EFST Extra Flexible UA UL Listed CSA Approved RWS Greenfield RWA Greenfield Hot Dipped Zinc Galvanized Steel Core Cord Packing Polyvinyl Chloride Cover Size Range: 1/4 thru 6 - Black or Gray Hot Dipped Zinc Galvanized Steel Core Polyvinyl Chloride Cover Direct Burial and in Concrete: 3/8 thru 4 Size Range: 3/8 thru 4 - Black or Gray Other Colors Upon Request Interlocked Zinc Coated Strip Steel Size Range: 3/8 thru 4 Lightweight Aluminum Smooth Inside and Outside Size Range: 3/8 thru 4 For Vibration, Movement, Crossover Connections and Tight Bends Temperature Range: -4 F to +140 F (-20 C to +60 C) Where UL Listing is Required and Conduit Grounding is Necessary Temperature Range: -40 F to +176 F (-40 C to +80 C) Flexible with High Crush Resistance Meets Requirements of UL1 and NEC F Maximum Temperature Flexible with High Crush Resistance Meets Requirements of UL1 and NEC F Maximum Temperature CW Computer Blue 11 Hot Dipped Zinc Galvanized Steel Core with Polyvinyl Chloride Cover Direct Burial and in Concrete: 1/2 thru 3 Size Range: 1/2 thru 3 Other Colors Upon Request Computer Wiring Meets Requirements of NEC Article (D) (2) Information Technology Under Raised Floors. Temperature Range: -40 F to +176 F (-40 C to +80 C) Harsh Environment Extra Flex NMUA General Purpose HTUA High Temperature HC High Low Temperature HCX Extreme High Low Temperature XTHF Extreme Temperature Zero Halogen ZHUA Zero Halogen OR Oil Resistant EFL Corrosion Resistant Aluminum MTC Machine Tool Conduit CNP Extra Flexible Smooth Inner Core Polyvinyl Chloride Cover Type B Non-Metallic Conduit Size Range: 3/8 thru 2 - Gray Hot Dipped Zinc Galvanized Steel Core Special Polyvinyl Chloride Cover for Temperature Extremes Direct Burial and in Concrete: 3/8" thru 4" Size Range: 3/8" thru 4"- Black or Gray Hot Dipped Zinc Galvanized Steel Core EFST Core Design with Special Polyvinyl Chloride Cover for Temperature Extremes Size Range: 3/8" thru 4"- Black or Gray Hot Dipped Zinc Galvanized Steel Core EFST Core Design with Special Thermoplastic Rubber Cover for Extreme Temperatures Size Range: 3/8 thru 4 - Black Hot Dipped Zinc Galvanized Steel Core with Bonding Wire thru 1" Special High Temperature Zero Halogen Cover Size Range: 1/2" thru 1" - Gray Hot Dipped Zinc Galvanized Steel Core with Bonding Wire thru 1-1/4" Special Zero Halogen Cover Direct Burial and in Concrete: 3/8" thru 4" Size Range: 3/8" thru 4" - Black Hot Dipped Zinc Galvanized Steall Core EFST Core Design with Special Oil Resistant Polyvinyl Chloride Cover Size Range: 3/8 thru 4 - Gray Lightweight Corrosion Resistant Aluminum Core Polyvinyl Chloride Cover Size Range: 3/8 thru 4 - Gray Hot Dipped Zinc Galvanized Steel Core Polyvinyl Chloride Cover Size Range: 3/8 thru 2 - Black Smooth Inner Core Nylon Braided Reinforcement Type A Non-Metallic Conduit Size Range: 3/8 thru 2 - Orange or Gray General Purpose Non-Metallic-Smooth Inner/Outer Wall Temperature Range: of -17 F to +176 F (-27 C to +80 C). Ideal for Environments with Extreme Temperatures and UL Listing is Required Temperature Range: -51 F to +221 F (-46 C to +105 C) High and Low Temperature Environments Temperature Range: -51 F to +221 F (-46 C to +105 C) Where Flexibility is Required in Extreme Temperature Environments Static installations temperature range: -76 F to +302 F (-60 C to +150 C) For Restricted or Self-Contained Ventilation Areas Temperature ranges -94 F to F (-70 C to +200 C) For Restricted or Self-Contained Ventilation Areas Temperature ranges -40 F to F (-40 C to +80 C) Where Exposure to Cutting OIls Occur Temperature Range: -9 F t o +221 F (-23 C to +60 C) Where the Atmosphere is Corrosive and added Flexibility and Crush Strength is Important Temperature Range: -4 F to +140 F (-20 C to +60 C) Extra Flexible. For Use in Machine Centers and Robotics Temperature Range: -4 F to +140 F (-20 C to +60 C) Where Abrasion or Physical Abuse are Factors, Constant Flexing or Movement Temperature Range: -4 F to +140 F (-20 C to +60 C) 4 CAT-ID ANAMET Electrical, Inc.
5 Flexible Conduit Types Product Type Pg Application Certifications STAINLESS STEEL FITTINGS 316 S/S COMPACT FITTINGS NICKEL PLATE BRASS COMPACT FITTINGS STEEL FITTINGS NON-METALLIC FITTINGS DE-710 DSL SL Square Locked UI Fully Interlocked FIRETECH SHIELDTITE EMI/RFI SHIELDTITE Z1 EMI/EMP Zero Halogen NMFG Food Grade FG Food Grade Stainless Steel Type 304 fitting Excellent corrosion resistance and strength Offered in Straight and 90 Size Range: 3/8 thru 1 Stainless Steel Type 316 fitting Excellent corrosion resistance and strength Offered in Straight and 90 Size Range: 3/8 thru 2 Nickel-Plated Brass fitting Excellent corrosion resistance and strength Offered in Straight,45 and 90 Size Range: 3/8 thru 2 Zinc-Plated Steel fittings. Made in the USA. Offered in Straight, 45 and 90 Size Range: 3/8 thru 2. Larger sizes available upon request. Type Nylon 66 with O Ring and Steel Lock Nut Direct Burial and in Concrete Size Range: 3/8 thru 2 - Gray Hot Dipped Zinc Galvanized Steel Core, Unpacked Size Range: 5/16 thru 3/4 Hot Dipped Zinc Galvanized Steel Core, Unpacked Size Range: 3/16 thru 3/4 Type 302 Stainless Steel Core Size Range: 1/8 thru 5/8 Fully Interlocked Type 302 Stainless Steel Core Size Range: 5/32 thru 1/2 Fittings can be installed with all Anaconda Sealtite Liquid tight flexible metal conduit. Approved for both exposed and concealed locations. Temperature Range: -49 F to +221 F (-45 C to +105 C) Fittings can be installed with all Anaconda Sealtite Liquid tight flexible metal conduit. Approved for both exposed and concealed locations. Temperature Range: -49 F to +221 F (-45 C to +105 C) Fittings can be installed with all Anaconda Sealtite Liquid tight flexible metal conduit. Approved for both exposed and concealed locations. Temperature Range: -49 F to +221 F (-45 C to +105 C) Fittings can be installed with all Anaconda Sealtite Liquid tight flexible metal conduit. Approved for both exposed and concealed locations. Temperature Range: -49 F to +221 F (-45 C to +105 C) Type B LFNC Straight and 90 Fittings Temperature Range: -40 F to +212 F (-40 C to +100 C). Extra Flexible Extra Strength +450 F Maximum Temperature Ideal for Applications Where Tight Bends are Required F Maximum Temperature Flexible with High Crush and Corrosion Resistance 1800 F Maximum Temperature Flexible with High Crush and Corrosion Resistance. Product Will Not Spring Open or Unwind F Maximum Temperature FireTech is offered in various options Sleeve, Wrap, Tape and Sheet. FireTech is the perfect insulator in steel mills, glass manufacturers, and other places where conduit is exposed to fire, heat and molten splash. Built from high bulk fiberglass and coated with a thick covering of iron oxide red silicone rubber, FireTech can take continuous exposure to temperatures of 500 F and shed molten slag as hot as 2,000 F Special Bronze core With Special Polyvinyl Chloride Cover Size Range: 3/8 thru 4 - Gray Military Standard: MIL-STD 1310D Special Bronze core With Special Zero Halogen TPU jacket Size Range: 3/8 thru 4 - Gray Military Standard: MIL-STD 1310D Smooth Inner Core Polyvinyl Chloride Cover formulated for food and beverage applications Type B Non-Metallic Conduit Size Range: 3/8 thru 2 Hot Dipped Zinc Galvanized Steel Core. Flexible PVC jacket formulated for food and beverage applications per FDA CFR21 and NSF 51 requirements. Size Range: 3/8 thru 2 For High Level RFI and EMI Shielding Temperature Range: -51 F to +221 F (-46 C to +105 C) For High Level RFI and EMI Shielding Temperature Range: -40 F to +176 F (-40 C to +80 C) NSF Certified to NSF/ANSI 169 for special purpose food equipment or devices. Ideal for wash down and food processing Temperature Range: -30 F to +120 F (-35 C to +50 C) NSF Certified to NSF/ANSI 169 for special purpose food equipment or devices. Ideal for wash down and food processing Temperature Range: -4 F to +140 F (-20 C to +60 C) R Fittings Strip Wound Special NWC Nuclear Conduit Fixture Whips Hot Dipped Zinc Galvanized Steel Core with Bonding Wire Through 1-1/4 Special Radiation Resistant Cover Size Range: 3/8 thru 4 - Black 3/8 RWS conduit. Interlocked Zinc Coated Strip Steel. 14 gauge solid or stranded cooper wire. Screw-in, snaptite connectors. Nuclear Application or Where Radiation Protection is Necessary Temperature Range: -40 F to +192 F (-40 C to +89 C) Conductors rated for 600v and 15 amps. 90 C (dry) Maximum temperature. ANAMET Electrical, Inc. CAT-ID
6 Type EF General Grade Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Square-Locked Design 3/8" through 2" Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Delivers superior wiring protection where agency approvals are not required. Manufactured in a full range of trade sizes from 3/8" through 2". Smooth appearing jacket for exposed applications. Rated for temperature range of -4 F to +140 F (-20 C to +60 C). Provides liquid-tight raceway for electrical conductors. See Pages for fittings COMPLIANT Type EF Gray thermoplastic PVC jacket no bonding wire Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Carton Standard Carton Small Reels Standard Reels Inches mm Inches Inches Inches PER Length NAED Length NAED Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN Feet PIN Feet PIN 3/ / / / / NOTE: 1. Other colors available upon request. 2. Standard SEALTITE Type EFST is recommended in sizes above 2 TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type EF. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type EF conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end fittings. 6 CAT-EF ANAMET Electrical, Inc.
7 Type EFST Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Flexible All Purpose Liquid-Tight Flexible Metal Conduit (LFMC) Square-Locked Design with cord packing 5/16 through 1-1/4 Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Delivers superior wiring protection where agency approvals are not required. Manufactured in a full range of sizes from 1/4" through 6". Conduit sizes 2-1/2", 3", 3-1/2" and 4" are Type UA/EFST - See page 6 for specifications. Smooth appearing cover for exposed applications. Rated for temperature range of -4 F to +140 F (-20 C to +60 C). Provides liquid-tight raceway for electrical conductors. Interlocked Design 1/4 and 1-1/2 through See Pages for fittings COMPLIANT Type EFST Gray or Black thermoplastic PVC jacket no bonding wire Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Carton Standard Carton Small Reels Standard Reels Inches mm Inches Inches Inches PER Length NAED Length NAED Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN Feet PIN Feet PIN 1/ / / / / / / / / Note: 1. Gray Specification above. 2. Black Change third number in NAED code to Other colors available upon request. Typical Specification: Conduit shall be Anaconda SEALTITE Type EFST. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type EFST conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end fittings. ANAMET Electrical, Inc. CAT-EFST
8 Type UA UL Listed, CSA Certified Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant and flame retardant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Convieniet markings in feet for easy measurement Conduit used with standard liquid-tight fitting for easy installation. IP 67 Rated when installed with approved fittings. Approved for both exposed and concealed locations. Rated for temperature ranges -40ºF to + 176ºF (-40ºC to +80ºC). Approved as an equipment grounding conductor in sizes 3/8 through 1-1/4 if the total grounding path is 6 ft. or less, and the circuit conductors are protected by overcurrent devices rated at 20 amps or less for 3/8 and 1/2 and 60 amps or less for 3/4 through 1-1/4. Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Manufactured in a full range of trade sizes from 3/8" through 4". Approved for direct burial and in concrete trade sizes 3/8" through 4". Complies with UL Standard 360 File No. E18917; CSA C22.2 File No ; and NEC Article 350. Square-Locked Design with integral bonding wire 3/8" through 1-1/4" Interlocked Design 1-1/2" through 4" with no bonding wire NEC Articles Article (6) Equipment Grounding Article (D) Information Technology Equipment Article 350 Liquid-Tight Flexible Metal Conduit (LFMC) Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & 2 Article Elevator Wiring Methods Article (E) (2) Under Raised Floors org See Pages for fittings R U.L. LISTED CSA CERTIFIED COMPLIANT Type UA Gray or Black thermoplastic PVC jacket with integral bonding wire 3/8" through 1-1/4" Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Carton Standard Carton Small Reels Standard Reels Inches mm Inches Inches Inches PER Length NAED Length NAED Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN Feet PIN Feet PIN 3/ / / / / / / Note: 1. Gray - Specification above. 2. Black - Change third number in NAED code to Other Colors are available upon request. 4. 3/8-3/4 available in 25 and 50 cut lengths 5. Large reel sizes available upon request. Typical Specification: Conduit shall be Anaconda SEALTITE Type UA. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" thru 1-1/4". Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 3/8" thru 4". Conduit shall be UL listed, CSA certified and IP 66/67 rated when installed with approved end fittings. 8 CAT-UA ANAMET Electrical, Inc.
9 Type RWS Flexible Steel Conduit UL Listed Flexible Metal Conduit (FMC) Constructed of continuously interlocked, zinc-coated steel strip. Flexible with high crush resistance. Smooth exterior and interior allow for easy pulling and wire fishing. Uses standard flexible metal conduit fittings giving an IP40 rating. Continuous grounding contact. UL Listed Standard #1, File # E Manufactured in size range from 3/8" through 4". Complies with Article 348, NEC. NEMA 1 Enclosure. Permitted to be used in exposed and concealed locations (Article ); enclosed motor leads (Article (B); elevators, escalators, wheelchair lifts (Article ). Not for wet locations F Maximum temperature. Angle-Lock Design 3/8" through 4" NEC Articles Article , (5) and (B) Equipment Grounding. Article (D) Information Technology Equipment Article 348 Flexible Metal Conduit. (FMC) Article (B) Class I Div. 2. Article Elevator Wiring Methods Article (E) (2) Under Raised Floors UL LISTED COMPLIANT Type RWS Flexible steel conduit Ordering Information Approx Inside Approx Electrical Inside Outside Bend Weight Trade Size Diameter Diameter Radius lbs. Standard Coils Standard Reels Additional Packaging Inches mm Inches Inches Inches PER Length NAED Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN Feet PIN 3/ / / / / / / / / / / Note: 1. Additional put-ups available. TYPICAL SPECIFICATION: Conduit shall be Anaconda Type RWS. Conduit shall provide flexible raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel. Conduit shall be UL listed in electrical trade sizes 3/8 thru 4. ANAMET Electrical, Inc. CAT-RWS
10 Type RWA Reduced Wall Flexible Aluminum UL Listed Flexible Metal Conduit (FMC) Constructed of continuously interlocked aluminum strip. Flexible with high crush resistance. Superior corrosion resistance. Smooth exterior and interior allow easy pulling and wire fishing. Uses standard flexible metal conduit fittings giving an IP40 rating. Light weight, easy to cut. UL Listed Standard #1, File # E Manufactured in size range from 3/8" through 4". Complies with Article 348, NEC. NEMA 1 Enclosure. Permitted to be used in exposed and concealed locations (Article ); enclosed motor leads (Article (B); elevators, escalators, wheelchair lifts (Article ). Not for wet locations F Maximum temperature. Angle-Lock Design 3/8" through 4" NEC Articles Article , (5) and (B) Equipment Grounding. Article (D) Information Technology Equipment Article 348 Flexible Metal Conduit. (FMC) Article (B) Class I Div. 2. Article Elevator Wiring Methods Article (E) (2) Under Raised Floors UL LISTED COMPLIANT Type RWA Flexible aluminum conduit Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Coils Standard Reels Additional Packaging Inches mm Inches Inches Inches PER Length NAED Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN Feet PIN 3/ / / / / / / / / / / Note: 1. Additional put-ups available. TYPICAL SPECIFICATION: Conduit shall be Anaconda Type RWA flexible reduced wall aluminum conduit and be made of continuously interlocked aluminum strip. Conduit shall be UL listed in electrical trade sizes 3/8 thru CAT-RWA ANAMET Electrical, Inc.
11 Type CW Computer Blue UL Listed, CSA Certified, Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant and flame retardant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Approved for both exposed and concealed locations. Rated for temperature ranges -40 F to F (-40 C to +80 C). Approved as an equipment grounding conductor in sizes 3/8 through 1-1/4 if the total grounding path is 6 ft. or less, and the circuit conductors are protected by overcurrent devices rated at 20 amps or less for 3/8 and 1/2 and 60 amps or less for 3/4 through 1-1/4. Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Manufactured in a full range of trade sizes from 1/2" through 3". Approved for direct burial and in concrete trade sizes 1/2" through 3". Complies with UL Standard 360 File No. E18917; CSA C22.2 File No ; and NEC Article 350. Square-Locked Design with integral bonding wire 1/2" through 1-1/4" Interlocked Design 1-1/2" through 3" with no bonding wire NEC Articles Article (6) Equipment Grounding Article (D) Information Technology Equipment Article 350 Liquid-Tight Flexible Metal Conduit (LFMC) Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & 2 Article Elevator Wiring Methods Article (E) (2) Under Raised Floors See Pages for fittings Type CW Blue thermoplastic PVC jacket with integral bonding wire 1/2" through 1-1/4" U.L. LISTED CSA CERTIFIED COMPLIANT Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Carton Small Reels Standard Reels Inches mm Inches Inches Inches PER Length NAED Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN Feet PIN 1/ / / / / NOTE: 1. Other colors available upon request. 2. 3/8", 3-1/2 & 4" trade sizes available on special order. TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type CW. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 1/2 thru 1-1/4. Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 1/2 thru 3. Conduit shall be UL listed, CSA certified and IP 66/67 rated when installed with approved end fittings. R ANAMET Electrical, Inc. CAT-CW
12 Type NMUA UL Listed CSA Certified Non conductive Conduit Liquid-Tight Flexible Non-Metallic Conduit (LFNC) One-piece construction of rigid, non-metallic reinforcement embedded in flexible PVC wall for exceptional crush and corrosion resistance. Durable, sunlight resistant and flame retardant thermoplastic PVC that resists heat, oil and chemical breakdown. Conduit used with standard fittings for non-metallic conduit Type B for easy installation. IP 66/67 Rated when installed with approved fittings. Approved for both exposed and concealed locations. Rated for temperature ranges of -17 F to +176 F (-27 C to +80 C). Complies with NEC Article 356 and UL Standard 1660 File No. E ; CSA C22.2 File No Easy to install and cuts easily. Manufactured in a full range of trade sizes from 3/8" through 2". Approved for direct burial and in concrete trade sizes 3/8" through 2". Rigid PVC Reinforced 3/8" through 2" NEC Articles Article Equipment Bonding Jumpers Article (B) Equipment Grounding Article (D) Information Technology Equipment Article 356 Liquid-Tight Flexible Nonmetallic Conduit (LFNC-B) Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & 2 Article Elevator Wiring Methods Article (E) (2) Under Raised Floors See page 28 for fittings R U.L. LISTED CSA CERTIFIED COMPLIANT Type NMUA Gray thermoplastic PVC Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Carton Standard Reels Inches mm Inches Inches Inches PER Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN 3/ / / / / Note: 1. Black available upon request TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type NMUA. Conduit shall be constructed of non-metallic PVC material and shall be used for inside, outside and corrosive applications in accordance with Article 356 of the National Electric Code. Conduit shall be used in applications requiring a temperature range of -17 F to +176 F (-27 C to +80 C) for dry locations. Conduit shall be UL listed and CSA certified as Type B non-metallic conduit. Conduit IP 66/67 rated when installed with approved end fittings. 12 CAT-NMUA ANAMET Electrical, Inc.
13 Type HTUA Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant and flame retardant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Designed for most extreme temperature applications. UL Listed, CSA Certified Higher and Lower Temperatures Liquid-Tight Flexible Metal Conduit (LFMC) Square-Locked Design with integral bonding wire 3/8 through 1-1/4 Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Approved for both exposed and concealed locations Rated for temperature ranges UL temps -51 F to F (-46 C to +105 C), CSA -51 F to 167 F (-46 C to +75 C). Approved as an equipment grounding conductor in sizes 3/8 through 1-1/4 if the total grounding path is 6 ft. or less, and the circuit conductors are protected by overcurrent devices rated at 20 amps or less for 3/8 and 1/2 and 60 amps or less for 3/4 through 1-1/4. Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Manufactured in a full range of trade sizes from 3/8" through 4". Approved for direct burial and in concrete trade sizes 3/8" through 4". Complies with UL Standard 360 File No. E18917; CSA C22.2 File No ; and NEC Article 350. Interlocked Design 1-1/2 through 4 with no bonding wire NEC Articles Article (6) Equipment Grounding Article (D) Information Technology Equipment Article 350 Liquid-Tight Flexible Metal Conduit (LFMC) Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & 2 Article Elevator Wiring Methods Article (E) (2) Under Raised Floors See Pages for fittings R U.L. LISTED CSA CERTIFIED COMPLIANT Type HTUA Gray or Black thermoplastic PVC jacket with integral bonding wire 3/8" through 1-1/4" Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Cartons Small Reels Inches mm Inches Inches Inches PER Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN 3/ / / / / / / NOTE: 1. Gray Specification above. 2. Black Change third number in NAED code to 6. Available in small cartons and small reels only. 3. Other colors available upon request. TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type HTUA. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" thru 1-1/4". Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 3/8" thru 4". Conduit shall be UL listed, CSA certified and IP 66/67 rated when installed with approved end fittings. ANAMET Electrical, Inc. CAT-HTUA
14 Type HC Temperature Conditions Are Higher/Lower Than Normal Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Square-Locked Design with cord packing 3/8" through 1-1/4" Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Delivers superior wiring protection where agency approvals are not required. Manufactured in a full range of trade sizes from 3/8" through 4". Smooth appearing jacket for exposed applications. Rated for temperature range of -51 F to +221 F (-46 C to +105 C). Provides liquid-tight raceway for electrical conductors. Interlocked Design 1-1/2" through 4" See Pages for fittings COMPLIANT Type HC Gray or Black thermoplastic PVC jacket no bonding wire Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Carton Small Reels Inches mm Inches Inches Inches PER Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN 3/ / / / / NOTE: 1. Gray - specification above. 2. Black -Change third number in NAED code to 0. Available in small cartons and small reels only. 3. Sizes above 2" available on special order. 4. Other colors available upon request. TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type HC. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type HC conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end fittings. 14 CAT-HC ANAMET Electrical, Inc.
15 Type HCX Extreme Temperature Jacket Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant thermoplastic rubber jacket that resists heat, oil and chemical breakdown. Square-Locked Design with cord packing 3/8 through 1-1/4 Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Delivers superior wiring protection where agency approvals are not required. Manufactured in a full range of trade sizes from 3/8" through 4". Smooth appearing jacket for exposed applications. Static installations rated for temperature range of -76 F to +302 F (-60 C to +150 C). Dynamic installations at atmospheric pressure rated for -76 F to +221 F (-60 C to +105 C) Provides liquid-tight raceway for electrical conductors. Interlocked Design 1-1/2 through See Pages for fittings COMPLIANT Type HCX Black thermoplastic rubber jacket no bonding wire Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Carton Small Reels Inches mm Inches Inches Inches PER Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN 3/ / / / / Note: Sizes above 2 available on special order TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type HCX. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant rubber outer jacket. Type HCX conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end fittings. ANAMET Electrical, Inc. CAT-HCX
16 Type XTHF Extreme Temperature Halogen Free* Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant, flame retardant, LOW SMOKE and ZERO HALOGEN Silicone jacket that resists heat, oil and corrosive chemical breakdown. Designed for most extreme temperature applications. Meets the demands of today s higher temperature rated conductors. Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Rated for temperature range of -94 F to +392 F (-70 C to +200 C) and incursions up to 500 F (260 C) Flexible metal core meets requirements of UL Std. 360 sizes 1/2 through 1. Manufactured in sizes from 1/2" through 1". Square-Locked Design with integral bonding wire 1/2 through 1 MEETS or EXCEEDS the following STANDARDS Flame Resistant IEC Halogen Free IEC Toxicity Index NES 713 (1.0) Low Smoke Index NES 711 Solar Weathering IEC Oxygen Index 29.2 MEETS CHEMICAL COMPATIBILITY (MIL STD 810F, 504) Fuel - Jet Propellant 8 Hydraulic fluid Royco 756 Lube oil Royco 500 Cleaner Calla 855 Solvent (Isopropyl Alcohol) TT-I-735 De-Icer E36 Runway De icer Coolant Coolanol 25R Fire extinguisher foam Amerex AFFF Type XTHF Gray Extreme Temperature Halogen Free jacket with integral bonding wire 1/2" through 1 COMPLIANT Ordering Information Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Carton Inches mm Inches Inches Inches PER Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN 1/ / NOTE: 1. Gray Specification above. * Test data results obtained from an independent test laboratory. Consult factory for additional details. TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type XTHF. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 1/2 thru 1. Conduit shall have a sunlight resistant, flame retardant, LOW SMOKE AND ZERO HALOGEN SILICONE jacket in electrical trade sizes 1/2 thru 1. Conduit shall be IP 66/67 rated when installed with approved end fittings. 16 CAT-XTHF ANAMET Electrical, Inc.
17 Type ZHUA Zero Halogen-Low Smoke-Low Flame Spread* UL Listed Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant, flame retardant, LOW SMOKE and ZERO HALOGEN TPU jacket that resists heat, oil and chemical breakdown. Designed for most extreme temperature applications. Meets the demands of today s higher temperature rated conductors. Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Approved for both exposed and concealed locations. Rated for temperature ranges -40 F to F (-40 C to +80 C). Approved as an equipment grounding conductor in sizes 3/8 through 1-1/4 if the total grounding path is 6 ft. or less, and the circuit conductors are protected by overcurrent devices rated at 20 amps or less for 3/8 and 1/2 and 60 amps or less for 3/4 through 1-1/4. Suitable for use in hazardous locations per NEC Article 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Manufactured in a full range of sizes from 3/8" through 4". Approved for direct burial and in concrete trade sizes 3/8" through 4". All Sizes Comply with UL Standard 360 File No. E Square-Locked Design with integral bonding wire 3/8 through 1-1/4 Interlocked Design 1-1/2 through 4 with no bonding wire MEETS or EXCEEDS the following STANDARDS Flame Spread Index ASTM E162 Smoke Density (Generation) ASTM E662 Toxic Gas Generation Bombardier BSS 7239 Jacket Material is U.L. 94 Certified Conduit is U.L. 360 Listed NEC Articles Article (6) Equipment Grounding Article (D) Information Technology Equipment Article 350 Liquid-Tight Flexible Metal Conduit (LFMC) Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & 2 Article Elevator Wiring Methods Article (E) (2) Under Raised Floors See Pages for fittings Type ZHUA Black Zero Halogen jacket with integral bonding wire 3/8" through 1-1/4" U.L. LISTED COMPLIANT Ordering Information Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Carton Small Reels Standard Reels Inches mm Inches Inches Inches PER Length NAED Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN Feet PIN 3/ / / / / / / NOTE: 1. Black Specification above. 2. cul rating available in sizes 1/2 and 3/4. Temperature range -40 C to 60 C. Consult factory for additional details. * Test data results obtained from an independent test laboratory. Consult factory for additional details. TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type ZHUA. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8 thru 1-1/4. Conduit shall have a sunlight resistant, flame retardant, LOW SMOKE AND ZERO HALOGEN TPU jacket in electrical trade sizes 3/8 thru 4. Conduit shall be UL listed, and IP 66/67 rated when installed with approved end fittings. ANAMET Electrical, Inc. CAT-ZHUA
18 Type OR Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Square-Locked Design with cord packing 3/8 through 1-1/4 Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Delivers superior wiring protection where agency approvals are not required. Manufactured in a full range of trade sizes from 3/8" through 4". Smooth appearing jacket for exposed applications. Rated for temperature range of -9 F to +221 F (-23 C to +105 C). Provides liquid-tight raceway for electrical conductors. Interlocked Design 1-1/2 through See Pages for fittings COMPLIANT Type OR Black or Gray thermoplastic PVC jacket no bonding wire Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Carton Small Reels Inches mm Inches Inches Inches PER Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN 3/ / / / / NOTE: 1. Black specification above. 2. Gray Change third number in NAED code to 8. Available in small cartons and small reels only. 3. Sizes above 2 available on special order. TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type OR. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type OR conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end fittings. 18 CAT-OR ANAMET Electrical, Inc.
19 Type EFL Aluminum Core Light Weight Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked aluminum core for exceptional crush and corrosion resistance. Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Delivers superior wiring protection where agency approvals are not required. Manufactured in a full range of trade sizes from 3/8" through 4". Smooth appearing jacket for exposed applications. Rated for temperature range of -4 F to +140 F (-20 C to +60 C). Provides liquid-tight raceway for electrical conductors. Square-Locked Design with cord packing 3/8" through 1-1/4" Interlocked Design 1-1/2" through 4" See Pages for fittings COMPLIANT Type EFL Gray thermoplastic PVC jacket no bonding wire Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Carton Inches mm Inches Inches Inches PER Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN 3/ / / / / / NOTE: 1. Other colors available upon request. TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type EFL. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked aluminum core with sunlight resistant PVC outer jacket. Type EFL conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end fittings. ANAMET Electrical, Inc. CAT-EFL
20 Type MTC Machine Tool Conduit Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown. Conduit used with standard liquid-tight fitting for easy installation. IP 65 Rated when installed with approved fittings. Delivers superior wiring protection where agency approvals are not required. Manufactured in a full range of trade sizes from 3/8" through 2". Smooth appearing jacket for exposed applications. Rated for temperature range of -4 F to +140 F (-20 C to +60 C). Provides liquid-tight raceway for electrical conductors. Square-Locked Design 3/8" through 2" See Pages for fittings COMPLIANT Type MTC Black thermoplastic PVC jacket Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Carton Small Reels Inches mm Inches Inches Inches PER Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN 3/ / / / / Note: 1. Other colors available upon request. TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type MTC. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type MTC conduit shall be used for applications where agency approvals are not required. Conduit IP 65 rated when installed with approved end fittings. 20 CAT-MTC ANAMET Electrical, Inc.
21 Type CNP UL Listed, CSA Certified Non conductive Conduit Liquid-Tight Flexible Non-Metallic Conduit (LFNC) Constructed of smooth inner thermoplastic PVC core with outer PVC cover bonded together with nylon reinforcing braid. Durable, sunlight resistant and flame retardant thermoplastic PVC that resists heat, oil and chemical breakdown. Conduit used with standard fittings for non-metallic conduit Type A for easy installation. IP 66/67 Rated when installed with approved fittings. Approved for both exposed and concealed locations. Rated for temperature ranges of -4 F to +140 F (-20 C to +60 C). Complies with UL Standard 1660 Type A conduit File No. E-75863; CSA C22.2 File No. LL15257; and NEC Article 356. Easy to install and cuts easily. Manufactured in a full range of trade sizes from 3/8" through 2". Flexible, but tough; crush, abrasion and strain resistant. Where abrasion, physical abuse or constant flexing are a factor. Nylon Reinforced 3/8" through 2" NEC Articles Article Equipment Bonding Jumpers Article (B) Equipment Grounding Article (D) Information Technology Equipment Article 356 Liquid-Tight Flexible Nonmetallic Conduit (LFNC-A) Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & 2 Article Elevator Wiring Methods Article (E) (2) Under Raised Floors U.L. LISTED CSA CERTIFIED R COMPLIANT Type CNP Orange or Gray thermoplastic PVC Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Carton Standard Carton Reels Inches mm Inches Inches Inches PER Length NAED Length NAED Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN Feet PIN Feet PIN 3/ / / / / Note: 1. Colors available on request. 2. Gray, change 3 rd number in NAED code to 8 TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type CNP. Conduit shall be constructed of smooth inner thermoplastic PVC core with outer oil-resistant and sunlight resistant PVC outer cover. Conduit shall have nylon reinforcing layer between the core and outer cover. Conduit shall be assembled with approved fittings to provide liquid-tight raceway for wiring. Conduit shall be UL listed and CSA certified as a Type A non-metallic conduit and be used in applications requiring a temperature range of -4 F to +140 F (-20 C to +60 C). Conduit IP 65/67 rated when installed with approved end fittings. ANAMET Electrical, Inc. CAT-CNP
22 Fitting Selection Guide FITTING SERIES Steel Fittings LFMC Zinc-Plated NPT Compact LFMC Nickel-Plated Brass ISO Metric Compact LFMC Nickel-Plated Brass NPT Compact LFMC 316 Stainless Steel NPT LFMC 304 Stainless Steel NMUA FITTINGS LFNC Type B Nylon 66 STOCK ITEM Y/N FITTING SELECTION GUIDE INSULATED THROAT CONSTRUCTION EF, EFST, UA, CW HARSH ENVIRONMENT HTUA, HC, HCX, ZHUA, OR, FG, EFL SHIELDTITE PVC, ZERO HALOGEN NMUA (NON-METALLIC) TYPE B NMUA. MTC (MACHINE TOOL) Y Y IP 66/67 IP 66/67 IP 66/67 NA IP 65 Y N IP 66/67 IP 66/67 IP 66/67 NA IP 65 Y N IP 66/67 IP 66/67 IP 66/67 NA IP 65 Y N IP 66/67 IP 66/67 IP 66/67 NA IP 65 Y Y IP 66/67 IP 66/67 IP 66/67 NA IP 65 Y NA NA NA NA IP 66/67 NA MTC IP 65 - Protected from total dust ingress. Protected from low pressure water jets. IP 66 - Protected from total dust ingress. Protected from high pressure water jets from any direction. IP 67 - Protected from total dust ingress. Protected from immersion to 1 m depth. Zinc-plated fittings provide marginal corrosion resistance. Not to be used in salt or corrosive environments. Nickel-Plated Brass fittings provide better protection against corrosion. Use to prevent galvanic corrosion in neutral ph. 316 Stainless Steel fittings are the best corrosion protection. Use in very harsh environments to protect against galvanic and chemical corrosion. 22 CAT-SSLTC ANAMET Electrical, Inc.
23 304 Stainless Steel Fittings Stainless Steel Liquid-Tight Flexible Metal Conduit (LFMC) Fittings Stainless Steel Type 304 fitting, has a four piece construction consisting of a gland nut, sealing ring, high tensile grounding ferrule and body. Designed with an insulated throat to prevent wire damage during installation. Included sealing washer and stainless steel lock nut provides a means for connecting the fitting to boxes. Excellent corrosion resistance, strength and durability. Straight - NPT Thread 3/8 through NPT Thread 3/8 through 1 Fitting is ideal for use with standard liquid-tight conduit to allow easy installation. IP 66/67 Rated when installed with approved conduit. Approved for both exposed and concealed locations. Rated for temperature ranges -49ºF to + 221ºF (-45ºC to +105ºC). Suitable for harsh industrial, food and beverage, petrochemical, waste water, salt water and other corrosive applications. Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Manufactured in a range of trade sizes from 3/8" through 1". Complies with UL Standard 514B and CSA C22.2 combined File No. E NEC Articles Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & Stainless Steel Fittings Type 304 U.L. LISTED CSA CERTIFIED COMPLIANT Electrical Trade Size K.O. Size Dimensions Approx Weight (lbs.) Ordering Information Straight Fittings Inches mm Inches Inches PER Standard AEI A B C D Pkg. Package PIN 3/8 12 1/ /2 16 1/ /4 21 3/ Note: 1. Other sizes available on special order Electrical Trade Size K.O. Size Dimensions Approx Weight (lbs.) Ordering Information 90 Fittings Inches mm Inches Inches PER Standard AEI A B C D Pkg. Package PIN 3/8 12 1/ /2 16 1/ /4 21 3/ Note: 1. Other sizes available on special order ANAMET Electrical, Inc. CAT-SSLTC
24 316 Stainless Steel Compact Fittings 316 Stainless Steel fitting, has a four piece construction consisting of a gland nut, sealing ring, high tensile grounding ferrule and body. Included sealing washer and galvanized steel lock nut provides a means for connecting the fitting to boxes. Excellent corrosion resistance, strength and durability. Fitting is ideal for use with standard liquid-tight conduit to allow easy installation. IP 66/67 Rated when installed with approved conduit. Approved for both exposed and concealed locations. Rated for temperature ranges -49ºF to + 221ºF (-45ºC to +105ºC). Suitable for harsh industrial, food and beverage, petrochemical, waste water, salt water and other corrosive applications. Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Compact design is ideal for tight spaces. Complies with UL Standard 514B and CSA C22.2 combined File No. E Stainless Steel NPT Thread Flexible Metal Conduit (LFMC) Fittings NEC Articles Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & Straight and 90 - NPT Thread 3/8 through COMPLIANT 316 S/S Straight Compact Fittings Size Sealtite Min. Internal Dimensions in inches NPT Size (inch) Bore (mm) A B C D E Standard Package PIN Number Weight (lbs/100) 1/2 3/ /2 1/ /4 3/ /4 1-1/ /2 1-1/ S/S 90 Compact Fittings Size Sealtite Min. Internal Dimensions in inches Standard PIN Weight NPT Size (inch) Bore (mm) A B C D E Package Number (lbs/100) 1/2 3/ /2 1/ /4 3/ /4 1-1/ /2 1-1/ CAT-NPTCF ANAMET Electrical, Inc.
25 NPT Compact Fittings Nickel Plated Brass NPT Thread Flexible Metal Conduit (LFMC) Fittings Nickel plated brass fitting, has a four piece construction consisting of a gland nut, sealing ring, high tensile grounding ferrule and body. Included sealing washer and galvanized steel lock nut provides a means for connecting the fitting to boxes. Excellent corrosion resistance, strength and durability. Fitting is ideal for use with standard liquid-tight conduit to allow easy installation. IP 66/67 Rated when installed with approved conduit. Approved for both exposed and concealed locations. Rated for temperature ranges -49ºF to + 221ºF (-45ºC to +105ºC). Suitable for harsh industrial, food and beverage, petrochemical, waste water, salt water and other corrosive applications. Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Compact design is ideal for tight spaces. Complies with UL Standard 514B and CSA C22.2 combined File No. E Straight and 90 - NPT Thread 3/8 through 2 NEC Articles Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & NPT Thread 3/8 through NPT Straight Compact Fittings COMPLIANT Size Sealtite Min. Internal Dimensions in inches NPT Size (inch) Bore (mm) A B C D E Standard Package PIN Number Weight (lbs/100) 1/2 3/ /2 1/ /4 3/ /4 1-1/ /2 1-1/ NPT 45 Compact Fittings Size Sealtite Min. Internal Dimensions in inches Standard PIN Weight NPT Size (inch) Bore (mm) A B C D E Package Number (lbs/100) 1/2 3/ /2 1/ /4 3/ NPT 90 Compact Fittings Size Sealtite Min. Internal Dimensions in inches Standard PIN Weight NPT Size (inch) Bore (mm) A B C D E Package Number (lbs/100) 1/2 3/ /2 1/ /4 3/ /4 1-1/ /2 1-1/ ANAMET Electrical, Inc. CAT-NPTCF
26 ISO Metric Compact Fittings Nickel Plated Brass ISO/Metric Thread Flexible Metal Conduit (LFMC) Fittings Nickel plated brass fitting, has a four piece construction consisting of a gland nut, sealing ring, high tensile grounding ferrule and body. Includes sealing ring. Excellent corrosion resistance, strength and durability. Fitting is ideal for use with standard liquid-tight conduit to allow easy installation. IP 66/67 Rated when installed with approved conduit. Approved for both exposed and concealed locations. Rated for temperature ranges -49ºF to + 221ºF (-45ºC to +105ºC). Suitable for harsh industrial, food and beverage, petrochemical, waste water, salt water and other corrosive applications. Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Compact design is ideal for tight spaces. Complies with UL Standard 514B and CSA C22.2 combined File No. E Straight - ISO Thread 3/8 through 2 NEC Articles Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & ISO Thread 3/8 through 2 COMPLIANT ISO Straight Compact Fittings Size Sealtite Min. Internal Dimensions in inches mm Size (inch) Bore (mm) A B C D E Standard Package PIN Number Weight (lbs/100) M16 X 1.5 3/ M20 X 1.5 3/ M20 X 1.5 1/ M25 X 1.5 3/ M32 X M40 X / M50 X / M63 X ISO 90 Compact Fittings Size Sealtite Min. Internal Dimensions in inches mm Size (inch) Bore (mm) A B C D E Standard Package PIN Number Weight (lbs/100) M16 X 1.5 3/ M20 X 1.5 3/ M20 X 1.5 1/ M25 X 1.5 3/ M32 X M40 X / M50 X / M63 X CAT-ISOCF ANAMET Electrical, Inc.
27 Steel Fittings Zinc plated steel fittings Liquid-Tight Flexible Metal Conduit (LFMC) Fittings Zinc plated steel fitting, has a five piece construction consisting of a gland nut, sealing ring, high tensile grounding ferrule, insulated throat, and body. Included sealing washer and galvanized steel lock nut provides a means for connecting the fitting to boxes. Corrosion resistant, protects from moisture and oils. Fitting is ideal for use with standard liquid-tight conduit to allow easy installation. IP 66/67 Rated when installed with approved conduit. Approved for both exposed and concealed locations. Rated for temperature ranges -49ºF to + 221ºF (-45ºC to +105ºC). Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2. Complies with UL Standard 514B and CSA C22.2 combined File No. E category code DWTT. NPT Thread 3/8 through 2 NEC Articles Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & Steel Straight SEALTITE Fittings R UL LISTED CSA CERTIFIED COMPLIANT Size Sealtite Min. Internal Dimensions in inches Standard PIN Weight NPT Size (inch) Bore A B C D Package Number (lbs/100) 1/2 3/ STR38B 10 1/2 1/ STR50B 13 3/4 3/ STR75B STR100B /4 1-1/ STR125B /2 1-1/ STR150B STR200B 85 ** 2-1/2-4 malleable iron fittings available upon request. Steel 45 SEALTITE Fittings Size Sealtite Min. Internal Dimensions in inches Standard PIN Weight NPT Size (inch) Bore A B C D Package Number (lbs/100) 1/2 * 3/ STR3845B 21 1/2 * 1/ STR5045B 23 3/4 * 3/ STR7545B 32 1 * STR10045B /4 * 1-1/ STR12545B /2 * 1-1/ STR15045B 99 2 * STR20045B 152 * Malleable iron body ** 2-1/2-4 malleable iron fittings available upon request. Steel 90 SEALTITE Fittings Size Sealtite Min. Internal Dimensions in inches Standard PIN Weight NPT Size (inch) Bore A B C D Package Number (lbs/100) 1/2 * 3/ STR3890B 24 1/2 * 1/ STR5090B 24 3/4 * 3/ STR7590B 38 1 * STR10090B /4 * 1-1/ STR12590B /2 * 1-1/ STR15090B * STR20090B 180 * Malleable iron body ** 2-1/2-4 malleable iron fittings available upon request. ANAMET Electrical, Inc. CAT-STLF
28 Non-Metallic Fittings Type B Liquid-Tight Flexible Non-Metallic Conduit (LFNC) Fittings All type nylon 66 construction with O ring and steel lock nut included. Reusable and durable fittings are flame retardant and resist salt water, weak acids, gasoline, alcohol, oil grease, and common solvents. Fittings used with standard non-metallic Type B conduit for easy installation. Approved for both exposed and concealed locations. Rated for temperature ranges of -40 F to +212 F (-40 C to +100 C). Easy to install, by pushing the non-metallic conduit onto the smooth ferrule and tightening the sealing nut. Manufactured in a full range of trade sizes from 3/8 through 2. Complies with NEC Article 356 and UL Standard 514B File No. E Straight fittings approved for direct burial and in concrete trade sizes 3/8 through 2. Straight Fitting NPT 3/8 Through 2 90 Fitting NPT 3/8 through 2 NEC Articles Article Equipment Bonding Jumpers Article (B) Equipment Grounding Article 356 Liquid-Tight Flexible Nonmetallic Conduit (LFNC-B) Article (B) (2) Class I Div. 2 Article (A) (2) and (B) (2) Class II Div. 1 & 2 Article (A) (3) and (B) Class III Div. 1 & 2 Article Elevator Wiring Methods Article (E) (2) Under Raised Floors COMPLIANT Non-Metallic Straight Fittings Gray nylon 66 Electrical Trade Size K.O. Size Dimensions Approx Weight (lbs.) Straight Fittings Inches mm Inches Inches PER Standard AEI A B C Pkg. Package PIN 3/8 12 1/ /2 16 1/ /4 21 3/ / / / / Non-Metallic 90 Fittings Electrical Trade Size K.O. Size Dimensions Approx Weight (lbs.) 90 Fittings Inches mm Inches Inches PER Standard AEI A B C Pkg. Package PIN 3/8 12 1/ /2 16 1/ /4 21 3/ / / / / CAT-NMUAC ANAMET Electrical, Inc.
29 Type DE-710 Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Extra Flexible steel construction. Recognized Component, for use by OEM s as part of manufactured wiring systems. Used in office furnishings, work stations and partitions. Exceptional flexibility for tight U bend radius. Complies with UL Recognized File No. E-39679; DXUZ2; CSA report No. LO-4000, Size range, actual I.D. 5/16" through 3/4". Available in custom-cut lengths F maximum temperature. Heavy-Duty UL Recognized Component Very flexible for OEM and Industrial Application Square Locked Design 5/16 through 3/4 NEC Articles Article 604 Manufactured Wiring Systems R UL RECOGNIZED COMPONENT CSA COMPONENT COMPLIANT Type DE-710 Unjacketed flexible steel conduit Ordering Information Approx Inside Approx Nominal Bend Weight Part Size Inches Inside Diameter Outside Diameter Radius lbs. Length Number Inches mm Inches Inches Inches PER NAED MIN. MAX. MIN. MAX. 100 FT. PIN 5/16* Random / Length / Coils / / / / Note: 1. Longer length reels available on request consult factory. * 5/16 size not UL recognized. TYPICAL SPECIFICATION: Heavy-Duty conduit very flexible for OEM and Industrial applications. Conduit shall be Anaconda Type DE-710. Conduit shall be constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Conduit shall be UL recognized as a part of a manufactured wiring system. ANAMET Electrical, Inc. CAT-DE
30 Type DSL All Purpose, Extra Flexible Uncovered Conduit Light Duty/General Electrical Application Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Extra Flexible continuously interlocked steel construction. Installs easily with standard armored cable or flexible conduit fittings. Exceptional flexibility for tight U bend radius. Designed to be used for specific applications where agency approvals are not required. Special sizes available upon request. Available in custom-cut lengths F maximum temperature. Square Locked Design 3/16 through 3/4 COMPLIANT Type DSL Unjacketed flexible steel conduit Ordering Information Approx Inside Standard Approx Nominal Inside Outside Bend Length Weight Part Size Inches Description Diameter Diameter Radius Coil lbs. Number Inches mm Number Inches Inches Inches PER PER NAED MIN. MAX. MIN. MAX. 100 FT. 100 FT. PIN 3/16 5 DSL /4 6 DSL /16 8 DSL /8 9 DSL /16 11 DSL /2 13 DSL /16 14 DSL /8 16 DSL /4 19 DSL TYPICAL SPECIFICATION: Conduit shall be Anaconda Type DSL. Conduit shall be constructed of continuously interlocked hot dipped zinc galvanized steel and provide a race-way for wiring. Conduit shall be considered all-purpose and be used for general purpose wiring where agency approvals are not required. 30 CAT-DSL ANAMET Electrical, Inc.
31 Type SL Square Lock Stainless Steel Stripwound Hose Constructed of continuously interlocked Type 302 stainless steel core for exceptional crush and corrosion resistance. Extruded PVC, Silicone, Teflon, and Thermoplastic Rubber jackets available upon request. Available in brass, galvanized steel and aluminum. Square Lock Applications Fiber Optics Instrumentation Sensors Recording Instruments Temperature Measuring Devices COMPLIANT Type SL Stainless Steel Stripwound Hose Ordering Information Approx Inside Approx Bend Weight Nominal Size Inside Diameter Outside Diameter Radius lbs. Standard Reel Inches mm Inches Inches Inches PER Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN 1/ / / / / / / / / / / / / / / NOTE: 1. Other sizes available on special order. 2. Available in brass, galvanized steel and aluminum. ANAMET Electrical, Inc. CAT-SL
32 Type UI Capillary Armor Stainless Steel Stripwound Hose Constructed of continuously interlocked Type 302 stainless steel core for exceptional crush and corrosion resistance. Product will not spring open or unwind. Extruded PVC, Silicone, Teflon, and Thermoplastic Rubber jackets available upon request. Available in brass, galvanized steel and aluminum. Interlocked Applications For applications with a max temperature of 1800 F Casings Armor Protection for wiring and capillary tubing Control cables Bar Dispenser casing COMPLIANT Type UI Stainless Steel Stripwound Hose Ordering Information Approx Inside Approx Bend Weight Nominal Size Inside Diameter Outside Diameter Radius lbs. Standard Reel Inches mm Inches Inches Inches PER Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN 5/ / / / / / / / / / / / / / / NOTE: 1. Other sizes available on special order. 2. Available in brass, galvanized steel and aluminum. 32 CAT -UI ANAMET Electrical, Inc.
33 FireTech High temperature Silicone coated fiberglass sleeve, tape, wrap and sheet. FireTech Sleeve FireTech Wrap FireTech Tape FireTech Sheet When Heat is Part of the Job FireTech is the perfect insulator in steel mills, glass manufacturers and other places where conduit is exposed to fire, heat and molten splash. Built from high bulk fiberglass and coated with a thick covering of iron oxide red silicone rubber, FireTech can take continuous exposure to temperatures of 500 F and shed molten slag as hot as 2,000 F for 15 minutes. Rugged and reliable, meets the requirements for criteria in the SAE Standard AS1055 Rev. D (Section and 4.1.2) for hose assemblies utilizing a firesleeve material and it is excellent for use in zero halogen environments. FireTech Sleeve RWA SEALTITE Wrap, Tape & Sheet FireTech Wrap FireTech Tape FireTech Sheet Inside Diameter PER PER Width PER PER PER Random Lengths Inches 50 FT. 100 FT. inches 50 FT. 100 FT. 36 FT. up to 150 FT. 5/ / / / / /8 3/ /2 1/ / /4 3/ / /4-1-1/2 1-1/4-1-1/ / /2 3 1/ / ANAMET Electrical, Inc. CAT-FT
34 SHIELDTITE Constructed of continuously interlocked high shielding bronze core for exceptional shielding effectiveness. Durable, abrasion resistant, flame retardant and sunlight resistant smooth thermoplastic PVC jacket that resists oil, heat and chemical breakdown. Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Meets Mil-STD-1310D for EMI and EMP shielding. Smooth interior surface protects sensitive conductors from harm. Provides shielding effectiveness of Db at 1 Megahertz to 1 Gigahertz. Rated for temperature range from -51 F to +221 F (-46 C to +105 C). Manufactured in a full range of sizes from 3/8" through 4". Available in custom-cut lengths. EMI/EMP for High Level Shielding Liquid-Tight Flexible Metal Conduit (LFMC) Interlocked Design 3/8 through 4 See Pages for fittings COMPLIANT SHIELDTITE Gray thermoplastic PVC jacket Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Part Number Inches mm Inches Inches Inches PER NAED MIN. MAX. MIN. MAX. 100 FT. PIN 3/ / / / / / AVAILABLE IN RANDOM LENGTHS TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type SHIELDTITE. Conduit shall have smooth cover and be constructed with bronze core of high level shielding. Conduit shall meet Mil-STD-1310D for EMI and EMP shielding effectiveness of Db at 1 Megahertz to 1 Gigahertz. Conduit shall be suitable for use within an operating temperature range of -51 F to +221 F (-46 C to 105 C). 34 CAT-SHIELDTITE ANAMET Electrical, Inc.
35 SHIELDTITE Z1 Constructed of continuously interlocked high shielding bronze core for exceptional shielding effectiveness. Durable, sunlight resistant, flame retardant, LOW SMOKE and ZERO HALOGEN TPU jacket that resists heat, oil and chemical breakdown. Designed for most extreme temperature applications. Meets the demands of today s higher temperature rated conductors. Conduit used with standard liquid-tight connector for easy installation. IP 66/67 rated when installed with approved connectors. Meets MIL-STD-1310D for EMI and EMP shielding. Smooth interior surface protects sensitive conductor from harm. Provide shielding effectiveness of Db at 1 Megahertz to 1 Gigahertz. Rated for temperature range from -40 F to 176 F (-40 C to +80 C) Manufactured in full range of sizes from 3/8 through 4. Available in custom-cut length. EMI/EMP Shielding - Zero Halogen Liquid-Tight Flexible Metal Conduit (LFMC) Interlocked Design 3/8 through 4 Tested to the following STANDARDS ASTM E 162 Flame Spread Index ASTM E662 - Optical smoke density SMP 800C Toxicity Toxic Gas Generation BSS 7239 ASTM C 1166 Flame Propagation See Pages for fittings COMPLIANT Type SHIELDTITE Z1 Gray Halogen Free jacket Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Part Number Inches mm Inches Inches Inches PER NAED MIN. MAX. MIN. MAX. 100 FT. PIN 3/ / / / / / AVAILABLE IN RANDOM LENGTHS TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type SHIELDTITE Z1. Conduit shall have a Low Smoke and Zero Holgen cover and be constructed with bronze core of high level shielding. Conduit shall meet Mil-STD 1310D for EMI and EMP shielding effectiveness of Db at 1 Megahertz to 1 Gigahertz. Conduit shall be suitable for use within operating temperature range of -40F to 176F (-40C to 80C). ANAMET Electrical, Inc. CAT-Z
36 Type NMFG NSF Certified Component Liquid-Tight Flexible Non-Metallic Conduit (LFNC) One-piece construction of rigid, non-metallic reinforcement embedded in flexible PVC wall for exceptional crush and corrosion resistance. Flexible thermoplastic PVC jacket formulated for food and beverage applications per FDA CFR 21 and NSF 51 requirements. Jacket is easily cleaned and does not promote bacteria growth NSF Certified to NSF/ ANSI 169 for special purpose food equipment or devices. Delivers superior wiring protection where incidental food contact is possible. Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Suitable for use in restaurants, food processing facilities, poultry packing facilities, meat packing facilities, wash down areas, waste water treatment, pharmaceutical applications and on special purpose food equipment or devices. Manufactured in a full range of trade sizes from 3/8" through 2". Rated for temperature range of -30 F to +120 F (-35 C to +50 C). Rigid PVC Reinforced 3/8 through 2 Places Of Interest Food Equipment or Devices NSF/ANSI 169 Food Equipment Manufacturers SIC 3556 Meat Packing SIC 2011 NAICS Poultry SIC 2015 NAICS Pharmaceuticals SIC 2834 NAICS See Page 28 for fittings NSF Component FDA Approved Compound COMPLIANT Type NMFG Blue thermoplastic PVC Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Carton Inches mm Inches Inches Inches PER Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN 3/ / / / / Note: 1. Other colors available on request. Typical Specification Conduit shall be Anaconda SEALTITE Type NMFG. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of non-metallic PVC material and shall be used for inside, outside and corrosive applications. Conduit IP 66/67 rated when installed with approved Type B fittings. Type NMFG conduit shall be used for applications where incidental food contact is possible. 36 CAT-NMFG ANAMET Electrical, Inc.
37 Type FG NSF Certified Component Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Flexible thermoplastic PVC jacket formulated for food and beverage applications per FDA CFR 21 and NSF 51 requirements. Jacket is easily cleaned and does not promote bacteria growth NSF Certified to NSF/ ANSI 169 for special purpose food equipment or devices. Delivers superior wiring protection where incidental food contact is possible. Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Suitable for use in restaurants, food processing facilities, poultry packing facilities, meat packing facilities, wash down areas, waste water treatment, pharmaceutical applications and on special purpose food equipment or devices. Manufactured in a full range of trade sizes from 3/8" through 2". Rated for temperature range of -4 F to +140 F (-20 C to +60 C). Square-Locked Design with cord packing 3/8 through 1-1/4 Interlocked Design 1-1/2" through 4" with no bonding wire Places Of Interest Food Equipment or Devices NSF/ANSI 169 Food Equipment Manufacturers SIC 3556 Meat Packing SIC 2011 NAICS Poultry SIC 2015 NAICS Pharmaceuticals SIC 2834 NAICS See Pages for fittings NSF Component FDA Approved Compound COMPLIANT Type FG White Thermoplastic PVC jacket no bonding wire Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Small Carton Inches mm Inches Inches Inches PER Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN 3/ / / / / Note: 1. Above 2 Available on special order. 2. Other colors available on request. Typical Specification Conduit shall be Anaconda SEALTITE Type FG. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with PVC outer jacket. Type FG conduit shall be used for applications where incidental food contact is possible. Conduit IP 66/67 rated when installed with approved end fittings. ANAMET Electrical, Inc. CAT-FG
38 Type NWC Nuclear Wiring Conduit Liquid-Tight Flexible Metal Conduit (LFMC) Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Durable, abrasion-resistant, smooth, chlorinated polyethylene jacket that resists heat, oil and chemical breakdown. Conduit used with standard liquid-tight fitting for easy installation. IP 66/67 Rated when installed with approved fittings. Suitable for use within nuclear containment areas. Flexible metal core meets requirements of UL Std. 360 sizes 3/8" through 4". Radiation resistant jacket meets IEEE and IEEE guidelines. Rated for temperature range of -40 F to F (-40 C to +89 C). Manufactured in a full range of sizes from 3/8" through 4". Square-Locked Design with integral bonding wire 3/8" through 1-1/4" Interlocked Design 1-1/2" through 4" with no bonding wire Listing NUCLEAR PROCURMENT ISSUES COMMITTEE (NUPIC) NUPIC number See Pages for fittings Type NWC Black chlorinated polyethylene jacket with bonding wire through 1-1/4" Ordering Information Approx Inside Approx Electrical Bend Weight Trade Size Inside Diameter Outside Diameter Radius lbs. Standard Carton Inches mm Inches Inches Inches PER Length NAED MIN. MAX. MIN. MAX. 100 FT. Feet PIN 3/ / / / / / TYPICAL SPECIFICATION: Conduit shall be Anaconda SEALTITE Type NWC. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" through 1-1/4". Jacket shall be black in color and be radiation-resistant. The outside of the jacket shall have a smooth appearance, Jacket material shall meet guidelines defined in IEEE and IEEE CAT-NWC ANAMET Electrical, Inc.
39 Fixture Whip Flexible Steel Conduit UL Listed Flexible Metal Conduit (FMC) Constructed of continuously interlocked, zinc-coated steel strip. 14 gauge solid or stranded copper white, black, and green wires Flexible with high crush resistance. 3/8 screw-in, snap-tite zinc diecast connectors on each end. Smooth exterior and interior allow for easy pulling and wire fishing. To be installed per UL category QQYZ, ANSI/NFPA 70, in addition to any local codes. Conductors are all rated for 600v and 15 amps. UL Listed File # E Complies with Article 348, NEC. Permitted to be used in exposed and concealed locations (Article ); electric signs and outline lighting in accordance with the most current ANSI/NFPA 70 NEC. 90 C (dry) Maximum temperature. Angle-Lock Design 3/8" NEC Articles Article , (5) and (B) Equipment Grounding Article (C) Other spaces used for Environmental Air Article (B) Class I Div. 2. Article Elevator Wiring Methods Article (E) (2) Under Raised Floors NEC Article (c) (B) Method of Grounding Motors, Motor Circuits, and Controllers (1) (2) Exception (1) Manufactured Wiring Systems UL LISTED COMPLIANT Type RWS Pre-Assembled fixture whips Ordering Information Approx Inside Approx Electrical Inside Outside Bend Weight Trade Size Diameter Diameter Radius lbs. Standard Inches mm Inches Inches Inches PER Length Wire Packaging NAED Config MIN. MAX. MIN. MAX. PCS Feet Gauge cartons drums PIN 3/ /2 SOLID - BLK/WHT / /2 STRAND - BLK/WHT / /3 SOLID - BLK/WHT/GRN / /3 STRAND - BLK/WHT/GRN Note: Custom whips available - contact customer service for details. TYPICAL SPECIFICATION: Conduit shall be Anaconda Type RWS. Conduit shall provide flexible raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel. With UL listed conductors and fittings. Conduit shall be UL listed in electrical trade sizes 3/8. ANAMET Electrical, Inc. CAT-RWSWHIP
40 Chemical Resistance Chart The listed chemicals have been tested with results noted below. It is recommended that samples of conduit should be tested under actual conditions wherever possible, since results may differ from test conditions. 1- Excellent 2- Good 3- Fair 4- Poor Continuous Service Intermittent Service Limited Service Life Do not use Jacket Material Jacket Material Chemical % TPR TPU PVC Chemical % TPR TPU PVC Acetate Solvents 4 Chromic Acid Acetic Acid Citric Acid 2 1 Acetic Acid (Glacial) 4 3 Coal Tar 4 Acetone Coconut Oil 3 Acrylonitrile 1 Corn Oil 1 Alcohols (Aliphatic) 3 Cottonseed Oil 3 Aluminum Chloride Creosote 4 4 Aluminum Sulfate (Alums) 2 1 Cresol 3 Ammonia (Anhydrous Liquids) 4 Cresylic Acid 4 Ammonia (Aqueous) 1 Cyclohexane 4 2 Ammoniated Latex 1 DDT Weed Killer 4 1 Ammonium Chloride Dibutyl Phthalate 4 4 Ammonium Hydroxide 2 1 Diesel Oils 4 3 Amyl Acetate 4 4 Diethylene Glycol 2 2 Aniline Oils 4 4 Diethyl Ether 1 Aromatic Hydrocarbons 4 Di-isodecyl Phthalate 4 Asphalt 4 4 Dioctyl Phthalate 1 4 ASTM Fuel A 2 3 Dow General Weed Killer (Phenol) 4 ASTM Fuel B Dow General Weed Killer (H2O) 2 ASTM # 1 Oil Ethyl Alcohol ASTM # 3 Oil Ethylene Dichloride 4 4 Barium Chloride 1 Ethylene Glycol Barium Sulfide 1 Ferric Chloride Barium Hydroxide 1 Ferric Sulfate 1 1 Benzene (Benzol) Ferrous Chloride 2 1 Benzine (Petroleum Ether) 4 3 Ferrous Sulfate 1 1 Black Liquor 1 Formaldehyde 1 4 Bordeaux Mixture 1 Fuel Oil 4 2 Boric Acid 2 1 Furfural 4 3 Butyl Acetate Gallic Acid 1 Butyl Alcohol Gasoline (Hi Test) Calcium Hydroxide 1 Glycerine Calcium Hypochlorite 1 Grease 1 1 Carbolic Acid (Phenol) 4 2 Green Sulfate Liquor 1 Carbon Dioxide 2 1 Heptachlor in Petroleum Solvents 1 Carbon Disulfide 4 4 Heptane Carbon Tetrachloride 4 4 Hexane Carbonic Acid 1 Hydrobromic Acid Casein 1 Hydrochloric Acid Caustic Soda Hydrochloric Acid 40 3 Chlorine Gas (wet) 2 4 Hydrochloric Acid 70 4 Chlorine Gas (dry) 2 4 Hydrofluorobonic Acid 1 Chlorine (water solution) 3 Hydrofluorosilicic Acid 4 1 Chlorobenzene Hydrogen Peroxide Chlorinated Hydrocarbons 4 Iso-octane CAT-CRC ANAMET Electrical, Inc.
41 Chemical Resistance Chart The listed chemicals have been tested with results noted below. It is recommended that samples of conduit should be tested under actual conditions wherever possible, since results may differ from test conditions. 1- Excellent 2- Good 3- Fair 4- Poor Continuous Service Intermittent Service Limited Service Life Do not use Jacket Material Jacket Material Chemical % TPR TPU PVC Chemical % TPR TPU PVC Isopropyl Acetate 4 Sulfur Dioxide (Liquid) 4 4 Isopropyl Alcohol Sulfuric Acid Jet Fuels (JP-3,4 and 5) 3 Sulfuric Acid Kerosene Sulfurous Acid Ketones 4 4 Tall Oil 4 1 Linseed Oil 4 1 Tannic Acid 4 1 Lubricating Oils 1 Toluene Magnesium Chloride Trichlorethylene 4 4 Magnesium Hydroxide 1 1 Triethanol Amine 3 Magnesium Sulfate 1 Tricresyl Phosphate (Skydrol) 4 4 Malathion 50 in Aromatics 4 Turpentine Malic Acid 1 Vinegar 1 Methyl Acetate Vinyl Chloride 4 Methyl Alcohol 4 3 Water Methyl Bromide 4 White Liquor 1 Methyl Ethyl Ketone 4 4 Xylene 4 4 Methylene Chloride Zinc Chloride 2 1 Mineral Oil 2 1 Zinc Sulfate 2 1 Monochlorobenzne 4 4 Muriatic Acid (See Hydrochloric Acid) 2 - Naphtha Naphthalene 4 4 Nitric Acid Nitric Acid Nitric Acid Oleic Acid 1 Oleum 4 Oxalic Acid 1 1 Pentachlorophenol in Oil 2 Pentane 4 3 Perchloroethylene Petroleum Ether 4 3 Phenol 4 2 Phosphoric Acid Pitch 2 Potassium Hydroxide 2 1 Propyl Alcohol 2 2 Ritchfield A Weed Killer 3 Sea Water Sodium Hydroxide Sodium Hydroxide Soybean Oil 3 Sodium Cyanide 1 Stoddard Solvent 4 Styrene 4 ANAMET Electrical, Inc. CAT-CRC
42 Part Number and Page Reference Part Number PG Part Number PG Part Number PG Part Number PG Part Number PG Part Number PG CAT-SSLTC ANAMET Electrical, Inc.
43 Part Number and Page Reference Part Number PG Part Number PG Part Number PG Part Number PG Part Number PG Part Number PG STR10045B STR10090B STR100B STR12545B STR12590B STR125B STR15045B STR15090B STR150B STR20045B STR20090B STR200B STR3845B STR3890B STR38B STR5045B STR5090B STR50B STR7545B STR7590B STR75B ANAMET Electrical, Inc. CAT-SSLTC
44 PRODUCT COMPARISON CHART ANAMET Electrical, Inc. Sealtite UA/CSA UL Listed/ CSA certified EFST 1/4-6 Extra Flex EF 3/8-2 EFL Aluminum CSA Same as UA Dual Listed HC Hot-Cold -46 C+105 C OR Oil-Resistant CW 1/2-3 Computer Wiring UL & CSA HCX High Temp. -60 C+150 C ZHUA Zero Halogen UL NWC Nuclear Conduit Shieldtite Special Core Shielding Conduit HTUA -46 C+105 C UL &CSA MTC 3/ C+60 C CNP 3/8-2 UL & CSA NMUA 3/8-2 UL & CSA Greenfield RWA/RWS Aluminum, Steel UL Electriflex Company Liquatite LA UL Listed CSA Certified LT 1/4-6 JIC EF 3/8-2 Extra Flex Const. Grade ALT 3/8-6 CSA CSA only LOR 3/8-6 Oil-Resistant LA Blue Computer Wiring UL & CSA ATX High Temp. -17 C+105 C ZHLA Non-Halogen UL Eastern Wire & Cable Canada Hydrotite UL UL Listed EF Extra Flex JIC LEF CSA CSA HTC SOR Oil-Resistant COM Computer Conduit UL & CSA SPEC-FLEX High temp -51 C+135 C SAF-T-FLEX 3/8-3 UL & CSA International Metal Hose Sealed Skin UALT UL Listed UL & CSA JIC 3/8-5 Extra Flex EFLT Contractor Grade CSALT UL & CSA HLT 3/8-5 Hot-Cold -40 C+105 C OR 3/8-5 Oil-Resistant CBLT Computer Conduit UL & CSA Alflex Corp. Ultratite UL UL Listed CSA Certified AFC Cable Systems Liquid-Tuff UL UL Listed CSA Certified VF Extra Flex (aka JIC) Kaf-Tech Superflex Carlon UL UL Listed CSA Certified VF Extra Flex (aka JIC) EF AEF OR Oil-Resistant CB Computer Blue UL & CSA OR Oil-Resistant Computer Blue UL Listed CSA Certified Extreme Temp -60 C+135 C LSZH 3/8-2-1/2 Zero Halogen UL OR Oil-Resistant Computer Blue UL Listed CSA Certified Extreme Temp -60 C+135 C LSZH 3/8-2-1/2 Zero Halogen UL EMS Shielding Conduit ATLA Hot-Cold -55 C+105 C VJC 3/ C+80 C LNM-P 3/8-2 UL & CSA NM 3/8-2 UL & CSA BR / ABR RW Steel, Aluminum UL MTLT 3/ C+90 C ONP 3/8-2 UL & CSA DURAFLEX 3/8-2 UL & CSA GFAU & GFSU Aluminum, Steel UL Hi-Low -40 C+105 C UL & CSA Hi-Low -40 C+105 C UL Hi-Low -40 C+105 C UL NMUA 3/8-2 UL RWA RWS R-W Steel, Aluminum UL NM 3/8-2 UL & CSA 5/16-4 R-W Steel, Aluminum UL LFNC-A 3/8-2 UL & CSA LFNC-B 3/8-2 UL & CSA R-W Steel, Aluminum UL LFNC-A 3/8-2 UL & CSA LFNC-B 3/8-2 UL & CSA R-W Steel, Aluminum UL Sealproof-B 3/8-2 UL & CSA CARFLEX 3/8-2 UL Listed 44 CAT-PKC ANAMET Electrical, Inc.
45 Packaging, Cutting Instructions Custom Cut Lengths Standard and Small Cartons Standard coils of Anaconda SEALTITE are packaged in handy, strong, corrugated cartons. These cartons keep stock clean and are easy to handle, stack and identify. Size, type, color and footage are prominently displayed on the side of each carton. A handy cutting instruction card is included in each carton. Smaller coils of Anaconda SEALTITE types EF, EFST and UA are also packaged in corrugated cartons with the same features as the standard coil cartons mentioned above. Smaller coils provide the same convenience as standard coils the shorter length allow for more economical purchasing on the smaller jobs. Non-returnable Standard and Small Wooden Reels Anaconda SEALTITE is available on nonreturnable wooden reels at no extra cost. Continuous lengths on reels eliminates scrap and special handling. For those who like the convenience of reels, but do not require the longer footages on the standard reels, Anamet offers smaller reels with less continuous footage on types EF, EFST, CW, UA and ZHUA conduit. Electrical Core Center Trade Size Flange Traverse* Diameter Hole (Inches) (Inches) (Inches) (Inches) (Inches) Standard Reel Dimensions 3/8 and 1/ /2 3/ /2 1 and 1-1/ /2 1-1/2 Small Reel Dimensions 3/8, 1/2, 3/4 1-1/2 & /2 1-1/2 *Measurement Between Flanges Large Reels Available on Special Request Hand Cutting SEALTITE with Metallic Core Importance of clean, square cut: Easier fitting attachment. Conduit makes full contact with base of liquid-tight fitting. Gives greater holding power to fitting. Assures a liquid-tight assembly throughout. Non-metallic SEALTITE Square, clean cuts are important for effective assembly with electrical fittings. Conduit is marked at 12" intervals for easy measuring. Type CNP conduit can be cut most easily with a sharpened parrot nosed electrical cable slicer. Good clean cuts can also be made with a sharp shoe knife. A little liquid detergent used to wet the knife blade will reduce frictional drag appreciably. Cutting the non-metallic conduit with a saw is not recommended. Production Cutting SEALTITE Using a Band Saw When cutting Anaconda SEALTITE with a band saw, the recommended blade specifications are: 1/2" wide x.025" thick, having 24 teeth per inch, no set. Blade speed should be approximately 350 ft. per minute. Band Saw cutting is recommended when extensive cutting Is required. Do NOT use abrasive wheel. Custom Cut Lengths Size range 1/8" to 2" Lengths up to 12 feet Quotations available upon request. Anamet Electrical Standard Cut Length Tolerances EXTENDED CUT LENGTHS TOLERANCES OVER TO PLUS MINUS " " IN THRU 8 IN 1/4 IN 0 8 IN THRU 18 IN 3/8 IN 0 18 IN THRU 3 FT 3/4 IN 0 3 FT THRU 6 FT 1-1/2 IN 0 6 FT THRU 12 FT 3 IN 0 12 FT THRU 20 FT 8 IN 0 20 FT THRU 49 FT 1 FT 0 49 FT AND UP 2 FT 0 Notes: 1 - This chart applies if no tolerances appear on drawing or factory orders. 2- This chart does not apply to product when it is to be cut in the Normal Lie position. ANAMET Electrical, Inc. CAT-PKC
46 Our Commitment High Customer Service Anamet Electrical, Inc. is committed to always meet or exceed our customers expectations. Services for Wiring Conduit Products Cutting to length Anamet has a cut length department with the experience and capabilities to meet all your design requirements. Whether you require small or large volumes or tight tolerances, we will meet your requests. Deburring When flexible metal conduit is cut, sharp edges and burrs remain. Anamet has several deburring machines that remove the sharp edges which can impede assembly or installation. Burnishing This process improves the appearance of stripwound stainless steel from a dull scratched appearance to a bright shiny mirrored finish. Customer specific marking on covered products Anamet can print custom text and small company or product logos on to the exterior of liquid tight flexible products. Braiding A flexible, tubular, metal sheath consisting of interwoven strands of wire. The primary purposes are to improve torque resistance and shielding. Color matching Anamet currently stocks many standard colors and we have the ability to match any Pantone color. This is an excellent way to improve brand recognition, product designation or to designate voltage. Special liquid tight covers Anamet offers a large variety of PVC, TPR, TPU, FEP and Silicone liquid tight covers. No matter how complicated your specifications might be, Anamet will accommodate your requirements. Tools Available Online at Instructions Chemical Resistance Chart NEMA Bulletins Passivation Passivation is the removal of iron compounds from the surface of stainless steel by means of a chemical dissolution that will remove the surface contamination but will not significantly affect the stainless steel itself. Anamet Electrical offers a 3 business day commitment on non-standard price requests. Contact Us Anamet Electrical, Inc Broadway Ave. East PO Box 39 Mattoon, IL Customer Service: (800) Fax: (800) [email protected] Office hours: 7:00 am - 5:00 pm CST - Monday-Friday Find us on the web! Visit 46 CAT ANAMET Electrical, Inc.
47 ANAMET Electrical, Inc. AN ANAMET COMPANY ANACONDA - SEALTITE Anamet Electrical, Inc. originated in 1908 as American Metal Hose, an outlet for the American Brass Company. Purchased in 1922 by Anaconda Mining Company, the company was in turn acquired by the Atlantic Richfield Company in In 1984 the company was sold to private and management investors under the name of Anamet Inc. Our manufacturing and warehouse facilities are located in Mattoon, Illinois; Ontario, Canada; and Amsterdam, The Netherlands. In addition, we have 15 stocking agent warehouses in the U.S. We have a global sales force and customer base. The origins of SEALTITE, a patented name owned by Anamet Electrical, Inc., are connected to the development of the first liquid-tight flexible electrical conduit for the machine tool industry in Underwriters Laboratories approved SEALTITE in Anamet Electrical continues its rich tradition of highly engineered, quality products used in applications ranging from machine tools, computer wiring, office furniture, nuclear power plants, petrochemical, naval, mass-transit, military shielding, and industrial construction. We continue to introduce new and innovative products to the market. Being a high-quality manufacturer, we meet or exceed the applicable UL, CSA, IEEE, and RoHS, standards. The majority of the product sold in the USA is manufactured in the USA. Anamet Electrical, Inc. is on many specifications due to the consistently high quality and performance of our products. A wide range of sizes and application solutions are available. 3% of gross sales are invested into Research and Development of new and improved products, annually. Customer Service is staffed by experienced, qualified personnel from 7am-5pm, Central Standard Time. We operate three manufacturing shifts and are able to fill orders quickly and completely, offering same day shipping of standard products upon request and before the appropriate cut-off times. Anamet Electrical, Inc. is also able to provide custom colors, custom cuts, custom packaging and custom imprints for our customers. We also offer EDI technology. Samples, engineering data, MSDS, and other requests can be fulfilled through our Customer Service department or through our web-site: Anamet Electrical, Inc. sells through distribution, pursuing a selective distribution strategy. We believe in the strategic importance of local distribution. Our three regional managers are supported by highly qualified Manufacturer s Representatives, and we are an active member of NAED and NEMRA. A rep locator is available on our web-site. Anamet Electrical, Inc. is financially sound with an excellent credit rating and a high D&B rating. Our facility in Mattoon, Illinois is located on 31 acres, with 230,400 square feet of manufacturing space. We have expansion capabilities to support our growing business. Our management structure is streamlined, which allows us to respond quickly to customers. ANAMET Electrical, Inc. CAT
48 ANAMET Electrical, Inc. AN ANAMET COMPANY Notes: 48 CAT ANAMET Electrical, Inc.
49 ANAMET Electrical, Inc. AN ANAMET COMPANY Notes: ANAMET Electrical, Inc. CAT
50 ANAMET Electrical, Inc. AN ANAMET COMPANY Notes: 50 CAT ANAMET Electrical, Inc.
51 ANAMET Electrical, Inc. AN ANAMET COMPANY Notes: ANAMET Electrical, Inc. CAT
52 ANAMET Electrical, Inc. ANACONDA SEALTITE Manufacturing and Sales - United States ANAMET ELECTRICAL, INC Broadway Avenue East P.O. Box 39 Mattoon, Illinois, United States, Phone: Fax: Manufacturing and Sales -Canada ANAMET CANADA, INC. 36 Wolfe St. P.O. Box 240 Frankfort, Ontario, Canada KOK 2C0 Phone: Fax: Manufacturing and Sales - Europe ANAMET EUROPE B.V AD Amsterdam P.O. Box 8155 Amsterdam, The Netherlands Phone: Fax: /2015
Carlon Carflex Liquidtight Flexible Tubing
Carlon Carflex Liquidtight Flexible Tubing Carflex Carflex X-Flex Fittings Cord Grips Pre-Wired Whips www.carlon.com 3 Carflex Liquidtight Flexible Conduit Carflex Liquidtight Flexible Nonmetallic Conduit
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com
* 2012 CATALOG AEROSPACE VVIRE & CABLE INC. A VV aerospacewire.com W e p r o u d l y m a n u f a c t u r e h i - t e m p w i r e & c a b l e. PLENUM CABLE. INDUSTRIAL CABLE. TRAY CABLE. MILITARY WIRE.
ETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
MaxCell Technical Manual Design Parameters
MaxCell Technical Manual Design Parameters Breaking Strength by Product Style, lbs Product Style Standard MaxCell Fire Resistant MaxCell Test Method 4 Cell 2,750 2,200 ASTM D 5 Bellcore 5 5.. Cell 2,50
- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Hook-Up and Lead Wire
3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:
FLEXTREME AND FLEXTREME IF
FLEXTREME AND FLEXTREME IF SOOW / SJOOW Flexible Cord TF Cable manufactures a superior industrial cable that offers a high value cosmetic appearance and greater mechanical strength by eliminating design
AMP Standard Terminals and Splices. RoHS. Ready
AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control
Tubing and Accessories
Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3
WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS
CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables
Building Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Thomas and Betts Corporation Product Guide Specification
Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described
TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations
TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations CableReady connectors are designed for use with the following cables: Type MC jacketed corrugated aluminum, interlocked
Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing
www.swagelok.com Multijacketed Tubing, Single-Jacketed Tubing, Insulated Tubing Features 1/4 to 6 to 12 tubing sizes available in 316/316L stainless steel copper Seamless welded tubing available in stainless
HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD
HVAC/R GAS TEST GAUGE Hex or Bell Type mounting 5 to00 Psi pressure ranges Steel case and brass internals Use to pressure test all new gas installations for leaks and passing inspection codes. After installing
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
FIRE RESISTANT CABLE CONSTRUCTION OF CABLES
FIRE RESISTANT CABLE In all fire disasters, fire smoke, heat and toxic fumes are the main obstacles to safe evacuation of a building or area. A major contribution towards overcoming these hazards is the
FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS
Perry Fiberglass Products, Inc. FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS PERRY FIBERGLASS Perry Fiberglass Products, Inc. is a leading manufacturer of high
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex
VIPERFLEX ELECTRIC CABLE
VIPERFLEX Flexible Low Voltage Electric Cable - 0.6/1kV (Rubber insulated) H07 RN-F & H07 BN-F Single Core 2-Core 2-Core and Earth 3-Core and Earth 4-Core and Earth Multi-Core and Earth H07 RCN-F & H07
V A P O R P R O O F b y D e s i g n
VAPORPROOF by Design Function, economy and durability. packed into a single fixture. The Canlet non-metallic vaporproof lighting fixture exceeds all requirements for standard vaporproof lighting. Made
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.
SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but
CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
RF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.
Basic Cable Assemblies DELIVERING QUALITY SINCE 1952. Cable Types Cable Types Hook-up & Lead Wire Most Basic 2 Cable Types Cable Types Twisted Pair Cable A type of cable that consists of two independently
Engineering Specifications
PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
SPEC 55. Wire and cable. Applications. SPEC 55PC wire and cable insulation system. Features and benefits. Physical characteristics
SPEC 55 Wire and cable Applications SPEC 55 wire is insulated with modified radiation cross-linked ETFE polymer. It has a temperature rating of -65 C to 200 C continuous using a silver plated copper conductor,
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER
Large numbers of electrical engineers have limited detail knowledge concerning wiring systems. There is the tendency by engineers to avoid becoming involved in the details of wiring systems, leaving the
DIRECTCONNECT SERVICE
DIRECTCONNECT SERVICE PRE-ASSEMBLED: LEADS, GROUNDS AND STINGERS/WHIPS Save Time, Labor and Money Lead Stinger/Whip Stock Colors (Blue, Green, Red, Yellow) available Stocked genuine Lenco and Tweco Connectors
DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Application Data Important Safety Information
Application Data Important Safety Information Read this page before using any of the information in this catalog. This catalog is designed to be used as a guide in selecting the proper hose for the applications
Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.
CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS September 2006 Revision 7 Corning Cable Systems reserves the right to update
Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index
Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device
Generator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
ASME Packaged Indirect Fired Water Heater
Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
Carton - Straight Link Machine Chain (Order Unit is Feet )
Straight Link Machine Individual chain links shown actual size in reference section page 44. Carton Uses: General utility; farm and animal Standard Material: Low carbon steel Standard Finish: Bright (BRT),
Cables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
TECHICAL SPECIFICATION Conductive Elastomer Extruded Gaskets
Pag. 1/8 TECHICAL SPECIFICATION Conductive Elastomer Extruded Gaskets Electrically conductive silicone gaskets are manufactured in different standard profiles and upon client request, in silicone and fluorosilicone,
BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.
CONDENSED CATALOG PVC HPB-0-A Effective 9//97 Revised //99 CLEAR / / / / -/ -/ -/ x/ CLEAR / / / / -/ PVC SDR. PSI (Water @ 7. F.) /.0.9.0.0 PVC SDR -/ -/ -/ 0 0 PVC SCHEDULE 0.0.7.0.00..7.7.00.000.00...
Session 14 Cable Support Systems
Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load
pvc well casing & drop pipe
CertainTeed pvc well casing & drop pipe PVC Well Products Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due to its outstanding
Terminal Cleaning and Protection
Terminal Cleaning and Protection East Penn offers the most complete line of terminal cleaning and protection products. Boots Heat Shrink Tubing Cleaner and Protection Sprays Terminal Protectors 33 PAGES
The Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
CT-02 CABLE TRAY SYSTEMS
CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry
Fire Life Safety ORC Review Guidelines for PPD Experimental Installations
Fire Life Safety ORC Review Guidelines for PPD Experimental Installations Fire Protection Review for the Fixed Target ES&H Review Committee September 2010 By James Priest PhD DRAFT Overview: When reviewing
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
HOSE & CABLE PROTECTION
HOSE & CALE PROTECTION Product Page AccessTrak, TrukTrak and TredTrak 2-5 FloorTrak 6 CableTrak Modular Carrier Track 7-9 Page 2 HOSE and CaLE PrOTECTION Features and enefits The AccessTrak ramping system
WHITE PAPER Fire & safety performance standards
WHITE PAPER Fire & safety performance standards Terminologies describing Fire Performance Terminologies describing Fire Performance often present a challenge to understand as how they apply to a cable
HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I.
FUEL LINE Temperature: -40 C to +125 C continuous service. Tube: Type C (Nitrile). Black. Oil and petrol resistant. Reinforcement: Single ply of synthetic fibre. Cover: Type C2 (NBR/PVC). Black. Fuel,
CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.
SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
CONFLEX ELECTRIC CABLE
CONFLEX ELECTRIC CABLE CONFLEX - 0.6/1kV Flexible VSD/EMC Cables Applications WW VSD/EMC cables are manufactured for use where electrical interference distorts signal transmission in electric motors. Standard
450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
F l u i d M a n a g e m e n t S o l uti o n s fo r t h e A e rospace Industry
F l u i d M a n a g e m e n t S o l uti o n s fo r t h e A e rospace Industry TABLE OF CONTENTS About Titeflex......................................................................................... 3
The MC Cable Revolution is Gaining Ground REMKE
The MC Cable Revolution is Gaining Ground June 2014 MC Cable Installation Continues to Improve with Advances in Materials and Fittings As the use of Metal Clad Cable grows, contractors are demanding better
ISO VIEW OF AX SERIES XLR CABLE CONNECTOR
ISO VIEW OF AX SERIES XLR CABLE CONNECTOR One piece ground / latch spring design incorporating twin wipe contacts for a direct connection path from mating shell to ground providing enhanced connection
UNITHERM UNITHERM 2256/2266 SELF-REGULATING ELECTRIC TRACE TUBING
UNITHERM UNITHERM 2256/2266 SELF-REGULATING ELECTRIC TRACE TUBING HIGH TEMPERATURE MAINTENANCE AND STEAM CLEANED LINES Principal of Operation Unitherm 2256/2266 HTM (High Temperature Maintenance) Electric
Protection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
PAINT BOOTH LIGHTING
PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING Lighting is comprised of many components that need to be considered when selecting the appropriate fixtures and lamps to accomplish a specific task. Selecting
Conduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC)
Conduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC) Download Buy American Brochure Includes 2011 National Electrical Code
LHD LINEAR HEAT D ETECTIONN
Tri-Metallic Core: Steel provides tensile strength Copper increase conductivity Tin for corrosion resistance LHD LINEAR HEAT D ETECTIONN TECHNICAL DATA Temperature Rating: 155 F (68 C) (typical temperature)
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
600V Power Cable 600V SOOW SOW
600V Power Cable Type SOOW UL/CSA 90 C 600V Part AWG No of Insulation Jacket Nominal Wieght/Mft Number Stranding conductors Thickness Thickness O.D. Nom. 18 2 SOOW 18 AWG 2.30 71 18 3 SOOW 16/.010 3.030
Universal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
STABILOY BRAND FeeDeR SOLuTIONS
STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
STABILOY BRAND FeeDeR SOLuTIONS
STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum
Cable-Gard Static Discharge Reels
Cable-Gard Static Discharge Reels Applications: Static discharge reels are used for grounding portable machines and equipment in hazardous areas, such as fuel transfer trucks, grain elevators, dockside
