INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING
|
|
|
- Lucy Wilcox
- 9 years ago
- Views:
Transcription
1 ISSN (ONLINE): INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING MINIMIZATION OF HEAT TRANSFER AREA OF AN AIR COMPRESSOR INTERCOOLER USING MATLAB Pawan Kumar Gupta Sr.Lecturer, Department of Mechanical Engineering, Babu Banarsi Das National Institute of Technology & Management, Lucknow, U.P., India Abstract Intercooling of air compressors is necessary for an efficient process. A heat exchanger of shell and tube type particularly suitable as an intercooler between compression stages of a compressor. A characteristic of heat exchanger design is the procedure of specifying a design, heat transfer area and pressure drops and checking whether the assumed design satisfies all requirements or not. The purpose of my research paper is to provide an easy and efficient way to design of an air compressor intercooler. Design methodology is based on the open literature and latest standard provided by the TEMA to industry. This paper describes modelling of heat exchanger which is based on the minimization of heat transfer area and a flow chart is provided showing the designing procedure involved. Based on the proposed algorithm MATLAB code is prepared. Computer codes for design are organized to vary systematically the exchanger parameters such as, shell diameter, baffle spacing, number of tube-side pass to identify configurations that satisfy the specified heat transfer and pressure drops. A case study is provided for which the program is run and the results obtained are compared with the available from industry data. Keywords: Air Compressor; Intercooler; Heat Exchanger; Shell & Tube Heat Exchanger. 1. INTRODUCTION Industrial plants use compressed air throughout their production operations, which is produced by compressed air units ranging from 5 hp to over 50,000 hp. It is worth noting that the running cost of a compressed air system is far higher than the cost of a compressor itself. The US Department of Energy (2003) reports that 70% to 90% of compressed air is lost in the form of unusable heat, friction, misuse and noise. For this reason, compressors and compressed air systems are important areas to improve energy efficiency at industrial plants. For improving efficiency compression is done in more than one stage and between each stage intercooler is provided. Intercooler improves the quality of air and reduces inlet air temperature. On doing this large quantities of condensate (water) are formed. Disentrainment of liquids can be a problem in intercooler systems of compressor plants, so proper separator arrangement should be made without considerable pressure drop. In industry, reciprocating compressors are the most widely used type for air compression. 1.1 Brief description of Air Compressor A machine which draws in air at atmospheric pressure then compresses it to pressures higher than atmospheric and delivers it at a rate sufficient to operate pneumatic tools or equipment. Pawan Kumar Gupta 20
2 A compressor is considered to be single stage when the entire compression is accomplished with a single cylinder or a group of cylinders in parallel. Many applications involve conditions beyond the practical capability of a single compression stage. Too great compression ratio (absolute discharge pressure/absolute intake pressure) may cause excessive discharge temperature or other design problems. Also as the outlet pressure increases, compression work done is also increases. To reduce the work of compression, compression is done in multi stage instead of single stage. In a single stage compressor operating at 100 psig at sea level, the compression ratio is 7.9 to 1 (in absolute terms). A two-stage compressor operating at the same pressure will have a compression ratio of 2.8 to 1 in each stage (2.8 is the square root of 7.9) achieving the compressor s power savings [2]. Two stage machines are used for high pressures and are characterized by lower discharge temperature (140 to 160 C) compared to single-stage machines (205 to 240 C). In some cases, multi-stage machines may have a lower specific power consumption compared to single stage machines operating over the same total pressure differential. Figure 1: Diagram of multistage compression with intercooling For practical purposes most plant air reciprocating air compressors over 100 horsepower or above 12 bar are built as multi-stage units in which two or more steps of compression are grouped in series. The air is normally cooled between the stages to reduce the temperature and volume entering the following stage. (National Productivity Council, 1993) [7]. Large compressors often use heat exchangers as after-coolers or as intercoolers between compression stages. The horsepower required for achieving the desired final pressure is related to the temperature and pressure of the fluid being compressed. The horsepower required increases if the temperature increases or the pressure decreases at any compression stage inlet. An intercooler should, therefore, effect a significant temperature change at minimal pressure loss Components of air compressor Intake Air Filters: Prevent dust from entering compressor; Dust causes sticking valves, scoured cylinders, excessive wear etc. Inter-stage Coolers: Reduce the temperature of the air before it enters the next stage to reduce the work of compression and increase efficiency. They are normally watercooled. After Coolers: The objective is to remove the moisture in the air by reducing the temperature in a water-cooled heat exchanger. Air-dryers: The remaining traces of moisture after after-cooler are removed using air dryers, as air for instrument and pneumatic equipment has to be relatively free of any moisture. The moisture is removed by using adsorbents like silica gel /activated carbon, or refrigerant dryers, or heat of compression dryers. Moisture Drain Traps: Moisture drain traps are used for removal of moisture in the compressed air. These traps resemble steam traps. Various types of traps used are manual drain cocks, timer based / automatic drain valves etc. Pawan Kumar Gupta 21
3 Air Receivers: Air receivers are provided as storage and smoothening pulsating air output - reducing pressure variations from the compressor. 1.2 Intercooler Inter-coolers are provided between successive stages of a multi-stage compressor to remove the heat of compression hence reduces the work of compression (power requirements). The work of compression (power requirements) is reduced by reducing the specific volume through cooling the air. Thus intercooling affects the overall efficiency of the machine. Ideally, the temperature of the inlet air at each stage of a multi-stage machine should be the same as it was at the first stage. This is referred to as perfect cooling or isothermal compression. But in actual practice, the inlet air temperatures at subsequent stages are higher than the normal levels resulting in higher power consumption, as larger volume is handled for the same duty. Generally air-to-liquid intercooler intercoolers are used due to its high heat transfer rate compare to air-to-air intercoolers. Air-to-liquid intercooler usually used water as an intermediate fluid. Air-to-liquid intercoolers are usually heavier than their air-to-air counterparts due to additional components making up the system (water circulation pump, fluid, and plumbing) Function of intercooler used in air compressor Intercooler used in air compressor performs following functions: Atmospheric air contains moisture, and furthermore, the air may pick up oil vapour as it passes through some compressors. Cooling the air down to or below its initial temperature will remove moisture down to the dew point, improving the quality of the air. Another purpose of intercooling is to improve the efficiency of compression. This is done by reducing the work of compression (power requirements). As the air comes out from compressor is at higher pressure as well as at higher temperature. This higher temperature may create problem for pneumatic tools, so intercoolers are used to reduce the outlet temperature of compressed air. Every 4 0 C rise in inlet air temperature results in a higher energy consumption by 1 percent to achieve equivalent output. Hence the intake of cool air improves the energy efficiency of a compressor [2] Principle components of Shell and Tube type heat exchanger In air compressor, Shell and Tube type heat exchanger is used as intercooler. They are usually air-to-water intercooler. Principal components of Shell and Tube type heat exchanger are given as: Shell, shell cover, tubes, channel, channel cover, tube sheet, baffles and nozzles. Figure 2: Diagram of a typical shell and tube heat exchanger, showing the components. A: Tubes; B: Tube sheets; C:Shell and Shell-side Nozzles; D:Tube-side Channels and Nozzles; E:Channel cover; F:Pass divider; G:Buffles.[9] A number of research papers are published related to multistage air compressor and shell and tube heat exchanger design. This literature review contains summary and results of research papers related to optimum location of intercooler and design of shell and tube heat exchanger. André L.H. Costa and Eduardo M. Queiroz [1] present a study about the design optimization of shell-and-tube heat exchangers. They take the optimization criteria as minimization of the thermal surface area Pawan Kumar Gupta 22
4 for a certain service, involving discrete decision variables. Decision variables are divided in two groups. The first group contains parameters that are defined by the engineer, since they are, partially or entirely, connected to broader engineering aspects and the second group includes parameters that can be searched to find the most economical design for the proposed service. Additional constraints represent geometrical features and velocity conditions which must be complied in order to reach a more realistic solution for the process task. The optimization algorithm is based on a search along the tube count table where the established constraints and the investigated design try to eliminate non optimal alternatives, thus reducing the number of rating runs executed. In the algorithm, an outer loop passes through the tube diameter set and another loop moves along the shell diameter set. For a certain shell diameter, the algorithm seeks to identify the smallest tube length which can fulfill the service. Thus, in the analysis of a certain tube length, the number of tube passes and baffle spacing are manipulated in order to find a feasible alternative. If there is no feasible design, the search moves to a larger tube length. If all values of tube lengths were investigated and no feasible design was found, the shell diameter is increased and the process is repeated. After the examination of all shell diameters, the tube diameter is increased and the search goes on. If the last tube diameter was analysed, the algorithm stops. The performance of the proposed algorithm is illustrated through the analysis of the results obtained in two examples of design tasks. The first example aims to compare the solution reached by the optimization algorithm with a previous recent literature approach, also based in a tube count table search. The objective of the second example is to characterize the behaviour of the computational effort according to the different components of the search algorithm. S. Murali and Y. Bhaskar Rao [16] develops tube sheet layout program for shell and tube heat exchangers. Program is written in Auto LISP language, which provides standard tube sheet layout drawing as per standard codes and non-standard tube sheet in AutoCAD Environment. The program computes the optimal number of tube count and lays out drawing with respecting constraints, including the shell ID, number of passes, center to center distance of tubes and tube outer diameter. In this program the input parameters shell diameter, tube diameter, tube orientation, tube pitch, number of passes and type of tube sheet such as Ribbon type, quadrant type and mixed type must be supplied by the user in input dialog box. The output of tube sheet layouts for rectangular 4 pass mixed horizontal and triangular 4 pass horizontal are obtained and shown with the help of drawing. This paper says that the 30 staggered layout has the highest tube density. Therefore, the largest heat transfer surface within a given shell can be obtained by 30 layout. This layout has also a high effectiveness of pressure drop to heat transfer conversion. Therefore, it should be primarily considered while choosing the appropriate tube layout. Comparison of present program results with the open literature is represented in form of graphs is done and is shown in Fig. 3 and 4. These depict that for given input parameters the present study gives more tube count. Figure 3: Tube count vs shell diameter 4 pass Pawan Kumar Gupta 23
5 Figure 4: Tube count vs shell diameter for 6 pass Su Thet Mon Than, Khin Aung Lin and Mi Sandar Mon [1] present the paper which provides basic procedure for design of heat exchanger. The purpose of this paper is how to design the oil cooler (heat exchanger) especially for shell-and-tube heat exchanger which is the majority type of liquid-to-liquid heat exchanger. General design considerations and design procedure are also illustrated in this paper and a flow diagram is provided as an aid of design procedure. In design calculation, the MATLAB and AutoCAD software are used. Normally, the heat exchanger design calculations are seems to be complex and repeated calculations are required with assumed and/or fixed data. So, many thermodynamic and fluid dynamic parameters are encountered into designs procedure and therefore this condition will satisfy and save the time by using a computer. To increase tube side heat transfer rate a tube insert is provided inside the tube. There are few limitations to be considered in program. To reduce size and cost of heat exchanger, U- Bend Exchangers are chosen. The arrangements of tubes are only for a widely used triangular pattern which permits the use of more tubes. The limitation of shell diameter is within the minimum 0.3 m and maximum 0.4 m. It is still assumed that there is no advantage in varying less than the allowable pressure drop and baffles will be employed within the minimum (one fifth of the shell diameter) and maximum (inside diameter of the shell) spacing. In this paper a case study is taken and variation of different-different variable and its effect on other variables are shown through the graphs. Results obtained are compared with the existing design result and is found that shell diameter for calculated design is nearly the same the existing design. But total numbers of tubes are more than existing design because of tube diameter changes. Furthermore, use simple insert flat plate in tubes. By using of tube inserts (flat plate) are highly effective in laminar flow inside tubes. The tube and shell pressure drop for acceptable limits is 0.6 and 0.3 bar. The calculated pressure drop for tube and shell are and bar. The design is satisfied because the pressure drop for both sides is lower than the limited pressure drop. Uday C. Kapale and Satish Chand [19] develop a theoretical model for shell-side pressure drop. They determine the overall pressure loss in the shell from the point of entry of the fluid to the outlet point of fluid. The model incorporates the effect of pressure drop into the various components as listed as: Pressure drop in the inlet and outlet nozzles at the end cross-sections of heat exchanger. The pressure drop in the interior cross sections. In these sections, the pressure loss is determined for the flow across the tube bundle and for the flow from interior section through window section to the next consecutive interior section. The pressure drop due to flow pattern in the inlet end cross-section across the tube bundle up to the level of baffle height and thereafter for the flow through window section. Similarly for the outlet end cross-section the pressure loss is first computed for the flow coming from the previous interior crosssection through window section and thereafter for the flow across the tube bundle. The result obtained through present model is compared with experimental results and results of the models developed by other. The present model results for water and oil fluids in the shell match with experimental results quite closely and the percentage error lies within +2.4% to -4.0%. Pawan Kumar Gupta 24
6 Yusuf Ali Kara, Ozbilen Guraras [20] made a computer-based design model for preliminary design of shell-and-tube heat exchangers with single-phase fluid flow both on shell and tube side. The program covers segmentally baffled U-tube, and fixed tube sheet heat exchangers one-pass and two-pass for tube-side flow. The design of a new heat exchanger (HE) is referred to as the sizing problem. In a broad sense, it means the determination of exchanger construction type, flow arrangement, tube and shell material, and physical size of an exchanger to meet the specified heat transfer and pressure drop. This sizing problem is also referred to as the design problem. Although design may be carried out by hand calculation, computer programs are widely employed anymore. A model is devolved and FOTRAN 90 code is developed based on the model described. Baffle spaces at inlet and outlet of the exchanger are assumed to be equal for simplicity. The program allows the user to choose the shell-side fluid and also to select optimization constraints, i.e., one is minimum shell side pressure drop and the other is allowable shell-side pressure drop. A sample operation conditions is taken and under this condition program is run. The program actually selects the optimum exchanger among the three different flow arrangement, namely one-pass, two-pass, and U-tube exchangers. The program is run for both cold and hot fluid as shell-side stream to show which one gives the best result. For instance, considering minimum shell-side pressure drop as constraining criteria for optimum design, circulating cold fluid in shell-side has some advantages on hot fluid as shell stream since the former causes lower shell-side pressure drop and requires smaller heat transfer area than the latter s. As a consequent, if there are no restrictions to allocation of streams, i.e., which fluid will flow through the shell, such as fouling fluid flow, high-pressure fluid flow or corrosive fluid, in general, it is better to put the stream with lower mass flow rate on the shell-side because of the baffled space. The present program is restricted to single-segmental baffle having 25% baffle cut that is most frequently used, triangular-pitch layout that results in greatest tube density. The exchanger type covers only fixed tube sheet with one-pass and two-pass, and U-tube for E-type shell. In example working fluid is taken water but working fluids other than water can also be introduced easily. 2 Initial Design Consideration of Intercooler 2.1 Fluid Stream Allocations There are a number of practical guidelines which can lead to the optimum design of a given heat exchanger. Remembering that the primary duty is to perform its thermal duty with the lowest cost yet provide excellent in service reliability, the selection of fluid stream allocations should be of primary concern to the designer. There are many trade-offs in fluid allocation in heat transfer coefficients, available pressure drop, fouling tendencies and operating pressure. Followings are some basic criteria for fluid placement. The higher pressure fluid normally flows through the tube side. With their small diameter and nominal wall thicknesses, they are easily able to accept high pressures and avoid more expensive, larger diameter components to be designed for high pressure. If it is necessary to put the higher pressure stream in the shell, it should be placed in a smaller diameter and longer shell. Place corrosive fluids in the tubes, other items being equal. Corrosion is resisted by using special alloys and it is much less expensive than using special alloy shell materials. Other tube side materials can be clad with corrosion resistant materials or epoxy coated. Flow the higher fouling fluids through the tubes. Tubes are easier to clean using common mechanical methods. Because of the wide variety of designs and configurations available for the shell circuits, such as tube pitch, baffle use and spacing, multiple nozzles, it is best to place fluids requiring low pressure drops in the shell circuit. The fluid with the lower heat transfer coefficient normally goes in the shell circuit. This allows the use of low-fin tubing to offset the low transfer rate by providing increased available surface. Following table 1 shows criteria for fluid placement, in order of priority. Pawan Kumar Gupta 25
7 Table 1: Criteria for Fluid Placement, in order of priority [15] Tube side fluid Corrosive fluid Cooling water Fouling fluid Less corrosive fluid Higher pressure stream Hotter fluid Shell side fluid Condensing vapor (unless corrosive) Fluid with large T (>100 F) 2.2 Selection of tube material To be able to transfer heat well, the tube material should have good thermal conductivity. Because heat is transferred from a hot to a cold side through the tubes, there is a temperature difference through the width of the tubes. Because of the tendency of the tube material to thermally expand differently at various temperatures, thermal stresses occur during operation. This is in addition to any stress from high pressures to the fluids themselves. The tube material also should be compatible with both the shell and tube side fluids for long periods under the operating conditions (temperatures, pressures, ph, etc.) to minimize deterioration such as corrosion. All of these requirements call for careful selection of strong, thermally conductive, corrosionresistant, high quality tube materials, typically metals. Poor choice of tube material could result in a leak through a tube between the shell and tube sides causing fluid cross-contamination and possibly loss of pressure. Materials selection and compatibility between construction materials and working fluids are important issues, in particular with regard to corrosion and/or operation at elevated temperatures. Requirement for low cost, light weight, high conductivity, and good joining characteristics often leads to the selection of aluminum for the heat transfer surface. On the other side, stainless steel is used for food processing or fluids that require corrosion resistance. In general, one of the selection criteria for exchanger material depends on the corrosiveness of the working fluid. Since in case of air compressor intercooler water is used as a cooling medium which is corrosive in nature and hence carbon steel or copper alloys will be used. A summary Table 2 is provided as a reference for corrosive and noncorrosive environments: Table 2: Material for corrosive and noncorrosive environments [15] Material Non-Corrosive Service Aluminum and austenitic Ni-Cr steel Heat Exchanger Type or Typical Service Any Heat Exchanger Type, T<-100 C 3 Ni steel Any Heat Exchanger Type, -100 C <T<-45 C Carbon steel, impact tested Carbon steel Refractory lined steel Corrosive Service Carbon steel Austenitic Ni-Cr steel Aluminum Copper alloy, admiralty aluminum brass Titanium Any Heat Exchanger Type, -45 C <T<0 C Any Heat Exchanger Type, 0 C <T<500 C Shell and Tube, T>500 C Mildly corrosive fluid, tempered cooling water Corrosion resistance duties Mildly corrosive fluid Fresh water cooling in surface condenser, sea water cooling See water coolers and condensers Pawan Kumar Gupta 26
8 Glass Carbon Coating aluminum epoxy resin Lining, lead and rubber Lining, austenitic Ni-Cr steel Air preheaters for large furnaces Severely corrosive services Exposure to sea and buckish water Channels for sea water coolers General corrosion resistance 2.3 Tube selection Tube size is designated as outer diameter, thickness and length. Some plant owners have a preferred outer diameter, thickness (usually based upon inventory considerations), and the available flow area will determine the maximum tube length. Tube diameter affects the heat transfer rate and thus the cost of heat exchanger. Smaller diameter tubes yield higher heat transfer coefficients and result in a more compact exchanger. But they may create cleaning problem while larger-diameter tubes are easier to clean. So, a compromise is made between these two and the most frequently used tube sizes are ¾ in. and 1 in. For water service ¾ in, 16BWG tubes are recommended. For oil service, 3/4 in., 14BWG tubes are recommended if the fluid is not fouling, while 1 in., 14BWG tubes should be used for fouling fluids [15]. Tube length also affects the cost and operation of heat exchangers. Longer the tube length (for any given surface area), fewer tubes are needed, requiring less complicated header plate with fewer holes drilled. Shell diameter decreases resulting in lower cost. Tubes are employed in 8 to 20 foot lengths, mechanical cleaning is limited to tubes 20 ft. and shorter. The ratio b/w length and shell diameter must be b/w 3 and 15 [1]. 2.4 Tube layout patterns The tube layout is defined by the characteristic angle and the corresponding definition of the tube pitch. Figure shows standard tube patterns generally used in industrial Heat Exchangers. The 30, 45 and 90 layouts are given but 60 layout is not considered because it produces lower effectiveness in pressure drop to heat transfer conversion for single phase flow applications and therefore is not generally recommended [16]. Figure 5: Tube layout patterns [16] The 30 staggered layout has the highest tube density. Therefore, the largest heat transfer surface within a given shell can be obtained by 30 layout. This layout has also a high effectiveness of pressure drop to heat transfer conversion. Therefore, it should be primarily considered while choosing the appropriate tube layout. However, it causes the highest pressure drop for a given tube pitch. The 45 staggered layout has also a high effectiveness of pressure drop to heat transfer conversion. However, when comparing with 30 layout, it is not more advantageous because it permits only about 85% of tubes within a given shell. An important advantage of 45 layout is that the pressure drop for a given pitch is less than for a 30 layout. Another advantage of 45 layout is the possibility of shell-side cleaning from outside by mechanical means, if sufficient clearance between tubes is allowed (approximately 7 mm). The 90 in-line layout should not be used in laminar shell-side flow, but it has also a high effectiveness of pressure drop to heat transfer conversion in turbulent flow. The cleaning convenience of shell- Pawan Kumar Gupta 27
9 INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING side from outside is the same as for 45 layout. The 90 layout should be considered as an alternative to the 30 or 45 staggered layout, especially if low pressure drop is desired. 2.5 Tube pitch Tube pitch is defined as the shortest distance between two adjacent tubes. For a triangular pattern, TEMA specifies a minimum tube pitch of 1.25 times the tube outer diameter. Thus, a 25-mm tube pitch is usually employed for 20-mm outer diameter tubes. For square patterns, TEMA additionally recommends a minimum cleaning lane of 4 in. (or 6 mm) between adjacent tubes. Thus, the minimum tube pitch for square patterns is either 1.25 times the tube outer diameter or the tube outer diameter plus 6 mm, whichever is larger. The tube pitch is the sum of the tube diameter and the clearance C. Figure 6 shows tube pitch in triangular pitch and square pitch pattern. Tube pitch is given as: Figure 6: Triangular pitch and square pitch PT = Tube pitch do = Tube outside diameter C = Clearance between tubes 2.6 Baffling Baffles are used to support tubes, enable a desirable velocity to be maintained for the shell side fluid, and prevent failure of tubes due to flow-induced vibration Type of baffles There are two types of baffles: plate and rod. Plate baffles may be single segmental, double-segmental, or triple-segmental, as shown in Figure 7. The single and double segmental baffles are most frequently used. They divert the flow most effectively across the tubes. The triple segmental baffles are used for low pressure applications. Figure 7: Types of Baffle [13] Pawan Kumar Gupta 28
10 2.6.2 Selection of Baffle spacing Baffle spacing is the centerline-to-centerline distance between adjacent baffles. The baffle spacing must be chosen with care because baffle spacing and not the baffle cut determines the effective velocity of the shell side fluid and hence has the greatest influence on shell side pressure drop. The TEMA standards specify the minimum baffle spacing as one-fifth of the shell inside diameter and the maximum baffle spacing is the shell inside diameter. There is an optimum ratio of baffle spacing to shell inside diameter (between 0.2 and 1) that will result in the highest efficiency of conversion of pressure drop to heat transfer. The baffle spacing cannot be lower than 50 mm [1]. Lower baffle spacing will lead to higher pressure drop [20]. The baffle spacing must obey the maximum unsupported span. Range of baffle spacing is given as [1]: B = Baffle spacing d s = Shell inside diameter Baffle cut Baffle cut is the height of the segment that is cut in each baffle to permit the shell side fluid to flow across the baffle. This is expressed as a percentage of the shell inside diameter. Baffle cut can vary between 15% and 45% of the shell inside diameter. Usually 25% baffle cut is used [18, 1, 20]. An ideal baffle cut is shown in Fig Tube passes Figure 8: Baffle Cut A pass is when liquid flows all the way across from one end to the other of the exchanger. We will count shell passes and tube passes. An exchanger with one shell pass and two tube passes is a 1-2 exchanger. Almost always, the tube passes will be in multiples of two (1-2, 1-4, 2-4, etc.). Odd numbers of tube passes have more complicated mechanical stresses. An exception: 1-1 exchangers are sometimes used for vaporizers and condensers. A large number of tube passes are used to increase the tube side fluid velocity and heat transfer coefficient and minimize fouling. This can only be done when there is enough pumping power since the increased velocity and additional turns increases the pressure drop significantly. Thus the number of passes depends on the available pressure drop. The number of tube passes in a shell generally range from 1 to 10. The standard design has one, two, or four tube passes. 2.8 Selection of shell and head types Shell and heads are decided mechanical cleaning, cost, thermal expansion and leakage of fluid. Shell and head types are presented in previous pages. The single pass type E shell is standard. If multiple shell passes are required, as indicated by LMTD correction factor F (F<0.7) [4,15], E shell connected in series or a two pass Pawan Kumar Gupta 29
11 type F shell can be used, although the longitudinal baffle may be subjected to leakage. These two are mainly used for intercooler. The most important consideration with respect to head type is fixed tube sheets versus floating head. A fixed tube sheet design is cheaper and less prone to leakage. However, the tube bundle cannot be removed to clean the exterior surface of the tubes. So, fixed tube sheet exchangers are usually restricted to service with clean shell side fluid Also, if the temperature difference between the two inlet streams is greater than about 100 F, an expansion joint is required in the shell of fixed tube sheet exchangers to accommodate the thermal expansion between the tubes and shell, which added cost to the exchanger. With floating head and U tube exchangers, the entire tube bundle can be pulled out of the shell from the front end. This allows mechanical cleaning of the exterior tube surfaces, usually high pressure jets of water or steam. Also, only tube sheets is attached to the shell (at the front end), the tubes are free to expand or contract relative to the shell due to temperature difference. The most widely used floating head design in the process industry is the AES exchange. U-tubes exchangers are less expansive, less costly and are also widely used. The advent of equipment for cleaning the interiors of U-tubes using high pressure water jets has mitigated the problem of cleaning the return bends, leading to increased use of these exchangers [16]. 2.9 Heat Balance for intercooler Heat load of an intercooler can be estimated from heat balance. In case of air compressor intercooler due to the presence of moister in air, heat load is computed by summing the sensible heat of air and moister with latent heat taken by moister to convert in to liquid water. Calculation for sensible heat Sensible heat of air is calculated as: Q air = m a c p (T 1 -T 2 ) (1) m a =mass of dry air Sensible heat of water vapor is calculated as: Q v = m v c p (T 1 -T 2 ) (2) m v =mass of water vapor present in air Calculation for Latent heat Some of the water vapor will converted in to water droplets by taking latent heat. Latent heat taken by the water vapor to convert in to liquid water is given as Q w = m w *Latent heat (3) m w =mass of water vapor converted in to water Hence the total heat taken by air (shell side fluid) is given as: Q = Q air + Q v + Q w (4) Heat balance between shell and tube side fluid now given as: Q = (mc p ) c (t 2 -t 1 ) = Q air + Q v + Q w (5) Figure 9: Inlet and outlet of both side fluids Q= Total heat transfer m= mass of fluid c p = specific heat at constant pressure T 1 = inlet temperature of hot fluid T 2 = outlet temperature of hot fluid Pawan Kumar Gupta 30
12 t 1 = inlet temperature of cold fluid t 2 = outlet temperature of cold fluid h and c =notation for hot and cold fluid respectively 2.10 Calculation of logarithmic mean temperature difference [LMTD] Generally both fluids under goes temperature variation which are not straight lines when temperatures are plotted against length L as shown in figure 10. At every point T-t between the two streams differs and shows logarithmically vary along length. Hence mean temperature difference is taken as logarithmic mean temperature difference instead of arithmetic mean temperature difference. Logarithmic mean temperature difference.m is given as [4, 14, 15]: T1 T2 T2 T1 θm = LMTD = = ln( T1 / T2 ) ln( T2 / T1 ) (6) Figure 10: Counter flow and Parallel flow [4,14] T 1 = T 1 t 2 T 2 = T 2 t 1 In case of 1-2 and multi pass shell and tube heat exchanger, the flow pattern is mixture of counter flow and parallel flow. For this reason, the mean temperature difference is not logarithmic mean temperature difference. However, it is convenient to retain the LMTD by introducing a correction factor F. In this case LMTD Ѳ m is given as: (Ѳ m ) 1-2 = F*LMTD (7) F is known as configuration correction factor for multiple shell side/ tube side passes. F can be calculated by using following relation [7,8,15] F = ( R 1) ln[( ( R + 1) S ( R + 1 ( R 2 ln 2 [(1 S ) (1 RS )] + 1) 0.5 ) /( 2 Where ( T1 T2 ) ( t2 t1) R = S = ( t 2 t1) ( T ), 1 t1 F can also be directly measure by using Fig. 11 shown below: S ( R + 1 ( R 2 + 1) )] (8) (9) Figure 11: LMTD correction factor[ 14,15] In case of one shell pass and two or more even numbered tube passes, it can be describe as parallel flowcounter flow as a 1-2 heat exchanger and the value of F obtained from above relation. The reason behind the Pawan Kumar Gupta 31
13 use of same F for 1-2 heat exchanger and more tube pass heat exchanger is that the value difference of F between 1-2 heat exchanger and 1-more number of pass tube heat exchanger will be very less approximate 2% [4]. 3. Modelling of Shell and Tube Heat Exchanger After making initial design consideration modelling of shell and tube heat exchanger is started. Modelling of shell and tube heat exchanger is done in following stages: Modelling of tube side Modelling of shell side 3.1 Modelling of tube side Tube side calculations are quite straightforward, since tube side flow represents a simple case of flow through a circular conduit. If all the tube side fluid were to flow through all the tubes (one tube pass), it would lead to a certain velocity. Usually, this velocity is unacceptably low and therefore has to be increased. 3.2 Calculations of Total Number of Tubes The suitable tube size, tube diameter and tube material are chosen first. The tube configuration has to be decided. The total number of tubes can be predicted as a function of the shell diameter by taking the shell circle D s and dividing it by the projected area of the tube layout pertaining to a single tube A 1. If number of tube is taken as N t, then N t = (Projected area of shell side covered by outer tube circle)/ (Projected area of the tube layout pertaining to a single tube) (10) Projected area of shell side (A s ) covered by tube circle is given as: 2 A s = π/4 D s (11) Since there is some necessary clearance between the shell and the outer tube circle, we introduce a constant to compensate it, Hence, 2 A s = (CTP) π/4 D s (12) CTP is the tube count constant which accounts for the incomplete coverage of the shell diameter by the tubes due to necessary clearances between the shell and the outer tube circle. The value of CTP for different-2 tube passes is as: CTP = 0.93 One tube pass CTP = 0.90 Two tube passes CTP = 0.85 Three tube passes Hence Number of tubes is calculated as: N t πd ( CTP) 4A 2 s = (13) 1 In Eq. 13 given above, A 1 has been replaced by as below by referring fig: A 1 = (CL) 2 P t (14) Pawan Kumar Gupta 32
14 Figure 12: Tube pitch for triangular and square configuration Hence [15], N t πd ( CTP) 4CLP 2 s 2 t = Here D s is the shell side diameter and P t is tube pitch. CL is known as tube layout constant and depends upon whether triangular or square pitch layout is used. The value of CL for different-2 tube pattern is as: CL = 1. for square (90 ) & rotated Square (45 ) pitch CL = for triangular pitch 3.3 Modelling for Tube-side Heat Transfer Coefficient The inside heat transfer coefficient can be evaluated using the standard approach for predicting heat transfer in flow through tubes, including applying a viscosity correction where possible. Typically, turbulent flow can be expected, and a good design would aim to arrange for turbulent flow, because of the substantial enhancement in heat transfer provided by eddy transport [2] Calculation for tube side mass flux Since total number of tube and total tube-side flow rate are known, tube side mass flux (G 1 ) can be solved as total flow rate divided by the tube-side flow passage area per pass [4, 8] i.e., G 1 = m t /a t (15) m t is total flow rate in tube side and a t is tube-side flow passage area per pass. Total tube-side flow passage area can be calculated by following equation: a t = π/4*d i (16) Here d i is tube inner diameter. Now tube-side flow passage area per pass a t can be calculated by multiplying at by N t /one pass i.e. a t = N t *a t /n p (17) Here n p is the number of passes used. Hence tube side mass flux (G 1 ) is given as: G 1 = m t * n p / N t *a t (18) Calculation for tube side Reynolds number The Reynolds number calculation is important to decide whether the flow is laminar or turbulence. The Reynolds number criteria for laminar and turbulence flow is given as [20]: If Re < 2300.flow is laminar 2300<Re > 10 4.Transition flow 10 4 >Re. flow is turbulent Reynolds number Re t is calculated as: Re t = di* G 1 /µ (19) Here µ is the viscosity of tube side fluid. Reynolds number is chosen such that flow is fully developed turbulent flow and is decided by setting number of tube passes. In calculating Reynolds number care should be taken that tube side fluid flow velocity, v, should be within optimum range and should be calculated as [15]: Pawan Kumar Gupta 33
15 v = 4* m t *(n p /N t )/ρ* π* d i 2 (20) ρ is the density of the fluid. In case of water it is taken as 1000 kg/m Calculation for Tube-side Heat Transfer Coefficient After calculating the Reynolds number of the flow inside the tube, Tube-side Heat Transfer Coefficient can be calculated by using following relation: For Laminar flow, Nu = = 1.86*(Re t*pr*d i /L) 1/3 *Φ 0.14 (21) For Turbulent flow, Nu = = 0.023*Re t 0.8 *Pr 1/3 *Φ 0.14 (22) Nu = Nusselt number Re t = Tube side Reynolds number h i = Tube side heat transfer coefficient φ can be taken as 1 for non-viscous fluid. Pr = Prandtl number k = Thermal conductivity of tube material d i = Tube inside diameter 3.4 Modeling of shell side The shell side calculations are far more complex than those for the tube side. This is mainly because on the shell side there is not just one flow stream but one principal cross-flow stream and four leakage or bypass streams as shown in figure. Figure 13: Diagram indicating the flow streams in the shell Tinker proposed calling these streams the main cross-flow stream (B), a tube-to-baffle-hole leakage stream (A), a bundle bypass stream (C), a pass-partition bypass stream (E), and a baffle-to-shell leakage stream (D). The B (main cross-flow) stream is highly effective for heat transfer, while the other streams are not as effective. The A stream is fairly efficient, because the shell side fluid is in contact with the tubes. Similarly, the C stream is in contact with the peripheral tubes around the bundle, and the E stream is in contact with the tubes along the pass-partition lanes. Consequently, these streams also experience heat transfer, although at a lower efficiency than the B stream. However, since the D stream flows along the shell wall, where there are no tubes, it encounters no heat transfer at all. Since the flow fractions depend strongly upon the path resistances, varying any of the following construction parameters will affect stream analysis and thereby the shell side performance of an exchanger: Baffle spacing and baffle cut. Tube layout angle and tube pitch. Number of lanes in the flow direction and lane width. Clearance between the tube and the baffle hole. Clearance between the shell I.D. and the baffle and location of sealing strips and sealing rods. Pawan Kumar Gupta 34
16 3.4.1 Calculation for Shell side mass flux Shell side mass flux (G 2 ) can be calculated as total flow rate of shell side fluid divided by the shellside or bundle cross flow area. i.e. G 2 = m s / a s (23) Here m s is the flow rate of shell side fluid and a s shell-side or bundle cross flow area. Shell-side or bundle cross flow area is calculated as [4]: a s = ID*C*B/P t (24) ID = internal diameter of shell, C = clearance, B = baffle spacing, P t = tube pitch Calculation for Shell side Reynolds number Reynolds number calculation for shell side is made in the same way as for tube side flow, except diameter taken is shell side equivalent diameter instead of actual diameter of shell. Shell side Reynolds number is calculated as: Re s = D e * G 2 /µ s (25) µ s = shell side fluid viscosity D e = Shell side equivalent diameter The equivalent diameter of the shell is taken as four times the net flow area divided by the wetted perimeter [4]: D e = (26) For square pitch, From figure, Free area = P 2 t - π d 2 o /4 (27) Wetted perimeter = 4*π d o /4 (28) = π d o Figure 14: Square pitch arrangement Hence, Shell side equivalent diameter D e can be calculated as: D e = 4*(P 2 t - π d o 2 /4)/ π d o (29) For Triangular pitch, From figure, Free area = 1 2 P t * 0.86 P t π d o 2 /4 (30) Wetted perimeter = 3*π d o /6 = π d o /2 (31) Pawan Kumar Gupta 35
17 Hence, Shell side equivalent diameter D e can be calculated as: D e = 4*( 1 2 P t * 0.86 P t π d o 2 /4) / 1 2 π d o (32) P t = tube pitch d o = tube outside diameter Figure 15: Triangular pitch arrangement Calculation of Shell side heat transfer coefficient: Calculation of shell side heat transfer coefficient is quite complex because of the presence of leakage stream as describe above. Ideal shell side heat transfer coefficient is calculated as: h ideal = J H (k/d e )Pr 0.33 Φ 0.14 (33) Here D e = shell side equivalent diameter, k = thermal conductivity of tube material and J H = colburn factor J H is given as J H = a 1. R (34) a =!".# &' (35) $% Value of a 1, a 2, a 3 and a 4 is taken from reference [6] h ideal calculated from this relation does not include correction factors for leakage for shell side flow. Actual shell side heat transfer coefficient can be calculated by consider correction factors for leakage for shell side flow. The stream analysis shell-side heat transfer coefficient for single-phase flow is used by following equation: h o = h ideal (J C J L J B J R J S J µ ) (36) h ideal = heat transfer coefficient for pure cross-flow in an ideal tube bank J C = correction factor for baffle cut and spacing J L = correction factor for leakage effects J B = correction factor for bundle bypass flow C & F streams J S = correction factor for variable baffle spacing in the inlet and outlet sections J R = correction factor for adverse temperature gradient build-up The combined effects of all these correction factors for a reasonable well-designed shell-and-tube heat exchanger are of the order of Jc is the correction factor for baffle cut and spacing. This factor takes into account the heat transfer in the window and calculates the overall average heat transfer coefficient for the entire heat exchanger. It depends on the shell diameter and the baffle cut distance from the baffle tip to the shell inside diameter. J C is calculated as [15,13,18]: J C = F C (37) Pawan Kumar Gupta 36
18 In this equation F C fraction between the baffle tips and is calculated as: F C = 1+1/π*(sinθ ctl -θ ctl ) (38) In this equation θ ctl is in radian and is calculated as: θ ctl = 2*cos -1 (D s (1-2B c )/D ctl ) (39) Figure 16: Baffle geometry [15] Here B c is baffle cut and D s is shell inside diameter. D ctl is the centerline tube limit diameter and is calculated as: D ctl = D otl + d t (40) d t is the tube outer diameter and D otl is outer tube limit diameter. F C = 1-2F W (41) F W = fraction of the cross-sectional area occupied by the window. Usually J C is taken in range [13,15]: 0.65< J C <1.175 J L is the correlation factor for baffle leakage effects including tube to- baffle and shell-to-baffle leakage (A- and E-streams). J L is a function of the ratio of total leakage area per baffle to the cross flow area between adjacent baffles ratio of the shell-to-baffle leakage area to the tube-to-baffle leakage area. A typical value of J L is in the range of 0.7 and 0.8. J L is calculated as [13,18]: J L =0.44(1-r S )+[1-0.44(1-r S )]exp(-2.2r lm ) (42) Here, ( %) r S = (43) ( *)!( %) r l = ( *)!( %) ( + (44) S tb is tube to baffle leakage area and is calculated as [15]: δ tb is tube to baffle clearance δ tb = 0.4..for d t >1.25 in. = 0.4 for d t 1.25 in. = 0.2 otherwise S tb =, - d tδ tb N t (1+F C ) (45) S sb is shell to baffle leakage area and is given as: S sb = D s δ sb (π-0.5θ ds ) (46) θ ds is baffle to window angle, in radians and δ sb is shell to baffle clearance. The baffle geometry in figure 4 remains valid if D ctl and θ ctl are replaced by D s and θ ds, respectively. It follows that: cos( - θ ds) =. %/ (47) % Hence, θ ds = 2*cos -1 (1-2B c ) (48) Pawan Kumar Gupta 37
19 and δ sb = D s (49) In this δ sb and D s are in mm. S m is cross flow area and is given as [13,15]: S m = B[(D s -D octl ) + (D octl -D t )(P t - D t )/(P t ) eff ] (50) B = central baffle spacing D octl = outer tube limit diameter (P t ) eff = P t.. for square and triangular layout = P t / 2.. for rotated square layout J B is the correction factor for bundle by passing effects due to the clearance between the outermost tubes and the shell and pass dividers (C- and F-streams). For relatively small clearance between the outermost tubes and the shell for fixed tube sheet construction, J B = For a pull-through floating head, larger clearance is required, J B = 0.7. J B is calculated as [1]: J B = exp[-c j (S b /S m )(1- r )].. For r ss < 0.5 (51) = 1.0..For r ss 0.5 C j = 1.35.for Re < 100 = 1.25.for Re : : ;<= r ss = (52) <89 : 89 : 2: 9< 9 ; 7 > Js is the correction factor for variable baffle spacing at the inlet and outlet. Because of the nozzle spacing at the inlet and outlet and the changes in local velocities, the average heat transfer coefficient on the shell side will change. The Js value will usually be between 0.85 and J S is calculated as [1]: (53) Figure 17: Single-segmental Shell and Tube Heat Exchanger Showing Baffle Spacing [18] Where; L bi = {1.25/N b + 1} L bo = L bi + 0.3D otl L bc = {1.25-2L bi }/{N b + 1} Here, N b = number of baffle compartments L bi = inlet baffle spacing, L bo = outlet baffle spacing, L bc = central baffle spacing J R applies if the shell-side Reynolds number, R es, is less than 100. If R es < 20, it is fully effective. J R is calculated as [13,14,18] Pawan Kumar Gupta 38
20 J R = (J R ) 20 = ( " ) > for 20 R es (54) = 1 for R es > 100 Where N C is the total number of tube rows crossed by the flow in the entire heat exchanger. The combined effect of all these correction factors for a well-designed shell-and-tube heat exchanger is of the order of Modeling for Overall Heat Transfer Coefficient After computing shell side and tube side heat transfer coefficient and using the fouling resistance for shell and tube side we can calculate the Overall Heat Transfer Coefficient U by using following relation:? = / / A 3 + BC -D EFBC BG + +I JC +I JG (55) A h o and h i = Shell side and tube side heat transfer coefficient respectively d o and d i = Tube side outlet and inlet diameter respectively k = Thermal conductivity of tube wall R fo and R fi = Fouling resistance associated with fluid outside tube and fluid inside tube respectively 3.6 Heat load computation and performance of above design The heat transfer surface area A is now calculated by the following equation: A = πd o LN t (56) Now heat load can be calculated as: Q = UAF T m (57) After calculated heat load it is compare with given heat load. If the calculated heat load is greater than the given heat load, it can be said that the design is satisfied. If not, by changing the design parameters whole procedure may be repeated till above condition is satisfied. 3.7 Pressure drop calculations Tube side pressure drop calculation As the fluid flow inside the tube, tube wall offers some resistance due to roughness and hence pressure drop occurs along the length of tube. This increases as increase in fluid velocity. In case of multiple pass or U- tube heat exchanger there is also pressure drop in tube bends. The pressure drop for tube side is computed from the summation of below given equations and comparing with allowable pressure drop. Calculation of the tube side pressure drop is made by first estimating the (Darcy) friction factor for flow through the tubes from the value of the Reynolds number and the relative roughness, and applying the viscosity correction. Then, this friction factor is used to evaluate the pressure drop for flow through the tubes from [4] P f = ½ ρ V 2 *n p *L/d i *f t (58) L = Length of tube, ρ = Density of tube side fluid (1000 kg/m 3 in case of water), d i = Inside diameter of tube, V = tube side fluid velocity, n p = Number of tube passes, f t = Darcy friction factor for tube side flow for Laminar flow f t = 16/Re t (59) for Turbulent flow Pawan Kumar Gupta 39
21 0.42 f t = /Re t (60) To this, we must add, the return pressure loss P r [18]. This accounts for the pressure drop associated with fluid entry into the tube bundle, fluid leaving the bundle, and fluid flowing around bends. P r =4*n p *G 2 1 /2ρ (61) Here, G 1 is the mass velocity for tube side flow Hence total tube side pressure drop is computed as: P = P f + P r (62) Shell side pressure drop calculation There are several ways to estimate the pressure drop for the flow of the shell-side fluid in a shell-andtube heat exchanger. A reasonable estimate can be obtained by the relatively simple approach described below, which is given in a book by D.Q.Kern [4] Equivalent diameter for pressure drop calculations in case of shell side fluid will be different from the diameter used for heat transfer calculations. This diameter is given as [8]: D es = 4a s /(P w +πd s ) (63) P w = Wetted perimeter and is computed as discussed earlier, D s = Shell side inner diameter The pressure drops for shell side fluid, is calculated using P s = - % K. % /7 )!3 L %. $% M N.' (64) ρ = Density of shell side fluid G 2 = Shell side mass flux N b = number of baffles f s = Friction factor for shell side and given as For Laminar flow f s = 16/Re s (65) For Turbulent flow 0.42 f s = /Re s (66) Re s is shell side Reynolds number. Based on above designing procedure an algorithm presented is shown next. 4 Problem formulation Based on the designing procedure and algorithm discussed earlier MATLAB code is made for designing of air compressor intercooler. The sample operation problem under which the program is run is given as below. This problem is taken from Bharat Pumps and Compressors Limited, Naini, Allahabad. Saturated air at kgf/cm 2 and at a rate of 27.5 kg/h (steam vapor rate is 0.85 kg/h) is discharged from a reciprocating air compressor s first stage at 170 C and is to be feed to second stage at 45 C using cooling water at cooling temperature 33 C.a pressure drop of 2.485e-4 kgf/cm 2 is allowable on the shell side and kgf/cm 2 on the tube side flow. 4.1 Designing of intercooler Designing of intercooler for this problem Initial design considerations are as follows: Since water is more corrosive in nature hence it is placed tube side, and also the air temperature is high so it is suitable to place it to shell side. For water service ¾ inches, 16BWG tubes are recommended. To increase the number of tube so that heat transfer increases I use triangular pitch pattern. Pawan Kumar Gupta 40
22 Material used for tube is copper alloy. U bend exchanger is used to reduce the cost. Baffles is employed within the minimum (one fifth of the shell diameter) and maximum (inside diameter of the shell) spacing. Segmental baffle with baffle cut taken as 25% is used as given in literature. 4.2 Figures showing relation between different-different variables and effect of variation of one variable to other The following figures are obtained by using the MATLAB code. Detailed discussion of these figures is also given. Figure 18: Variation of tube side Reynolds number Vs number of tubes Figure 18 shows variation of tube side Reynolds number with change in number of tubes. It can be seen that Reynolds number is gradually decreases corresponding to increasing in number of tubes. The reason behind this is that since mass flow rate of tube side fluid is constant, hence increasing the number of tubes decreases tube side fluid velocity and hence decreases tube side Reynolds number as tube side Reynolds number is directly proportional to the tube side fluid velocity as discussed. Figure 19: Variation of tube side Heat transfer coefficient Vs number of tubes Figure 19 shows variation of tube side Heat transfer coefficient with change in number of tubes. It can be seen that Heat transfer coefficient is gradually decreases corresponding to increasing in number of tubes. As Pawan Kumar Gupta 41
23 discussed above that Reynolds number is gradually decreases corresponding to increasing in number of tubes and since Heat transfer coefficient is directly proportional to the Reynolds number, hence increasing number of tubes decreases tube side Heat transfer coefficient. Figure 20: Variation of shell side Reynolds number Vs tube length Figure 20 shows variation of shell side Reynolds number with change in tube length. The decreasing pattern of curves of Reynolds Number shows that Reynolds Number gradually decreases corresponding increase in tube length. This is because as the tube length increases, for given number of baffle, baffle spacing will also increases. Due to increase in baffle spacing shell side flow area will also increases. Since shell side Reynolds number is anti-proportional to the shell side flow area, hence, increasing in tube length shell side Reynolds number decreases. However, this graph also shows that increasing in number of baffle, Reynolds number increases. This is because that the increase in number of baffle will increase the times the fluid to crosses tube bundle, hence, Reynolds number increases. Figure 21: Variation of shell side Heat transfer coefficient Vs tube length Pawan Kumar Gupta 42
24 Figure 21 shows variation of shell side Heat transfer coefficient with change in tube length. The decreasing pattern of curves of Heat transfer coefficient that Heat transfer coefficient gradually decreases corresponding increase in tube length. This is because as the tube length increases, for given number of baffle, Reynolds Number gradually decreases hence, Heat transfer coefficient decreases. However, this graph also shows that increasing in number of baffle, since Reynolds number increases, hence, shell side Heat transfer coefficient increases. Figure 22: Variation of tube side pressure drop Vs number of tube Figure 22 shows variation of tube side pressure drop with change in tube length. The decreasing pattern of curves of pressure drop shows that pressure drop initially decreases suddenly and after that gradually decreases corresponding increase in number of tube. The reason behind that as the number of tubes increases, since mass flow rate is constant, velocity in tubes will decreases. As the velocity of flow inside tube decreases pressure drop will also decreases. Figure 23: Variation of shell side pressure drop Vs baffle spacing Pawan Kumar Gupta 43
25 Figure 23 shows variation of shell side pressure drop with change in baffle spacing. The decreasing pattern of curves of pressure drop shows that pressure drop gradually decreases corresponding increase in baffle spacing. As the baffle spacing increases, for the given length of shell, shell side fluid will cross the tube bundle less times and hence pressure drop will decreases. 5 Result and its comparison Results obtained are summarized in following table 3. The comparison of presented model has been done with Results obtained from industry data. Industrial results are obtained using HTRI software. Table 3: Comparison of calculated result with industrial result Result Industrial data Calculated data Shell diameter, mm Tube length, mm Tube diameter, mm Velocity, m/s Baffle cut % Number of baffle Over all heat transfer coefficient, kcal/h-m 2 C Heat load, kcal/hr Pressure drop shell side, kg/cm Pressure drop tube side, kg/cm From table 3 we can see that results of the present model match closely with the industrial results. Overall heat transfer coefficient and Heat load calculated is more than those obtained using HTRI software, this is because of baffle cut and increase in number of baffles. Pressure drop is also within in optimum range. Hence the presented model results can be used by designer confidently. Conclusion In this paper we have studied about multistage air compressor & main components used in air compression system mainly intercooler. In this paper, we have used very simple and time efficient algorithms for designing of air compressor intercooler. A MATLAB code is done based on the proposed algorithm. This program gives efficient results for intercooler. Program is run according to the limits of variables. Placement of the fluid in shell or tube side is done mainly on basis of corrosion and fouling basis which affects more on the cost of intercooler. In this paper effect of tube length, number of tubes, fluid velocity, number of baffles and baffles spacing on heat transfer coefficient of both side fluid is illustrated with the help of proper graph. To increase tube density, so that heat transfer will increase, triangular pitch pattern is used. Pressure drop for both sides is trying to reduce with proper spacing of baffle and baffle cut and also with tube diameter and tube length. References 1. Andre L.H. Costa, Eduardo M. Queiroz, 2008, Design Optimization of Shell and Tube Heat Exchangers, Applied Thermal Engineering 28, Air Compressor Types and Components; 3. Bureau of Energy Efficiency; Chapter 3, Compressed Air System. 4. D.Q.Kern, 1950, Process Heat Transfer, Mc-Graw-Hill, New York, Pawan Kumar Gupta 44
26 5. D.R. Mitchell, Y.X.Tao and R.W. Besant, 1995, Air Filtration with Moisture and Frosting Phase Changes in Fiberglass Insulation- I Experiment, I. J. Heat Mass Transfer 38 (9), DOE/GO Compressed Air Tip Sheet #13 Remove Condensate with Minimal Air Loss, August Energy Efficiency Guide for Industry in Asia Electrical Energy Equipment: Compressors and Compressed Air Systems 8. Joydeep Berman, A.K.ghoshal, 2007, Performance Analysis of Finned Tube and Unbaffled Shell-and-Tube Heat Exchanger, International Journal of Thermal Sciences 46, Kenneth J. Bell, 2004, Heat Exchanger Design for the Process Industry, ASME Journal of Heat Transfer 126 (6), M. Thirumarimurugan, T.Kannadasan and E.Ramasamy, 2008, Performance Analysis of Shell and Tube Heat Exchanger Using Miscible System, American Journal of Applied Sciences 5 (5), P. Vadasz and D. Weiner, 1992, the Optimal Intercooling of Compressors by a Finite Number of Intercoolers, ASME 12. Perry, 1950, Chemical Engineering Handbook, 3rd Edition, Mc-Graw-Hill, New York. 13. Professor John R.Thom, 2004, Wolverine Tube Heat Transfer Data Book III, Wolverine Tube Inc, R.Shankar Subramanian, Shell and Tube Heat Exchanger, the Chemical Engineers Handbook; Chapter Robert W. Serth, 2007, Process Heat Transfer Principle and Applications, Academic Press, UK, S. Murali and Y. Bhaskar Rao, 2008, A Simple Tube sheet Layout Program for Heat Exchangers, American Journal of Engineering and Applied Sciences 1 (2), Simin Wang, Jian Wen, Yanzhong Lik, 2009, An experimental investigation of heat transfer enhancement for a shell-and-tube heat exchanger, Applied Thermal Engineering 29, Su Thet Mon Than, Khin Aung Lin, Mi Sandar Mon, 2008, Heat Exchanger Design, World Academy of Science, Engineering and Technology Uday C. Kapale, Satish Chand, 2006, Modeling for Shell-Side Pressure Drop for Liquid Flow in Shell-and- Tube Heat Exchanger, International Journal of Heat and Mass Transfer 49, Yusuf Ali Kara, Ozbilen Guraras, 2004, A Computer Program for Designing of Shell-and-Tube Heat Exchangers, Applied Thermal Engineering 24, Biography Mr. Pawan Kumar Gupta receives degree of Master of Technology from MNNIT, Allahabad in 2010,with first division with honours, and receives degree of Bachelors of Technology from SITM, Lucknow in 2008, with First division. He has published one International research paper. He is currently working as senior lecturer in Department of Mechanical Engineering, Babu Banarsi Das National Institute of Technology & Management, Lucknow, U.P., India. His area of research is CAD/ CAM, Thermal Design and Analysis, Robotics & Optimization. Pawan Kumar Gupta 45
TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE: WWW.WERMAC.ORG/
TEMA DESIGNATIONS OF HEAT EXCHANGERS Because of the number of variations in mechanical designs for front and rear heads and shells, and for commercial reasons, TEMA has designated a system of notations
Examples for Heat Exchanger Design
for Heat Exchanger Design Lauterbach Verfahrenstechnik GmbH 1 / 2011 Contents Calculation 1 1. Water- Water Heat Exchanger 1 Basics...1 Task...1 1. Start the WTS program...1 2. Selection of basic data...1
Selecting TEMA Type Heat Exchangers
Selecting TEMA Type Heat Exchangers TEMA is a set of standards developed by leading heat exchanger manufacturers that defines the heat exchanger style and the machining and assembly tolerances to be employed
Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger
Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger Nitesh B. Dahare Student, M.Tech (Heat power Engg.) Ballarpur Institute of Technology,
2.2. Basic Equations for Heat Exchanger Design
.. Basic Equations for Heat Exchanger Design... The Basic Design Equation and Overall Heat Transfer Coefficient The basic heat exchanger equations applicable to shell and tube exchangers were developed
Chapter 3 Single-Phase Shell-Side Flows and Heat Transfer
Chapter 3 Single-Phase Shell-Side Flos and Heat Transfer SUMMARY: The design method of Taborek (1983) for single-phase shell-side flos of shell-and-tube heat exchangers ith single segmental baffles is
5.2. Vaporizers - Types and Usage
5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,
Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati
Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati Module No. # 04 Convective Heat Transfer Lecture No. # 03 Heat Transfer Correlation
International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No.161-166, March-April 2015
International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No.161-166, March-April 2015 http://www.mnkjournals.com/ijlrst.htm ISSN (Online):2278-5299 EXPERIMENTAL STUDY
FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES
FREESTUDY HEAT TRANSFER TUTORIAL ADVANCED STUDIES This is the third tutorial in the series on heat transfer and covers some of the advanced theory of convection. The tutorials are designed to bring the
Corrugated Tubular Heat Exchangers
Corrugated Tubular Heat Exchangers HEAT EXCHANGERS for the 21st CENTURY Corrugated Tubular Heat Exchangers (CTHE) Corrugated Tube Heat Exchangers are shell and tube heat exchangers which use corrugated
SHELL & TUBE HEAT EXCHANGER THERMAL DESIGN WITH OPTIMIZATION OF MASS FLOW RATE AND BAFFLE SPACING
Research Paper SHELL & TUBE HEAT EXCHANGER THERMAL DESIGN WITH OPTIMIZATION OF MASS FLOW RATE AND BAFFLE SPACING 1 Sandeep K. Patel, 2 Professor Alkesh M. Mavani Address for Correspondence 1 L.D.R.P I.T.R,
CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
Design of heat exchangers
Design of heat exchangers Exchanger Design Methodology The problem of heat exchanger design is complex and multidisciplinary. The major design considerations for a new heat exchanger include: process/design
Open channel flow Basic principle
Open channel flow Basic principle INTRODUCTION Flow in rivers, irrigation canals, drainage ditches and aqueducts are some examples for open channel flow. These flows occur with a free surface and the pressure
Shell and Tube Heat Exchanger Design Software for Educational Applications*
Int. J. Engng Ed. Vol. 14, No. 3, p. 217±224, 1998 0949-149X/91 $3.00+0.00 Printed in Great Britain. # 1998 TEMPUS Publications. Shell and Tube Heat Exchanger Design Software for Educational Applications*
Natural Convection. Buoyancy force
Natural Convection In natural convection, the fluid motion occurs by natural means such as buoyancy. Since the fluid velocity associated with natural convection is relatively low, the heat transfer coefficient
Thermal design of shell-and-tube
Effectively Design Shell-and-Tube Heat Exchangers To make the most of exchanger design software, one needs to understand STHE classification, exchanger components, tube layout, baffling, pressure drop,
Department of Chemical Engineering, National Institute of Technology, Tiruchirappalli 620 015, Tamil Nadu, India
Experimental Thermal and Fluid Science 32 (2007) 92 97 www.elsevier.com/locate/etfs Studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with right
Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert
Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert Premkumar M Abstract Experimental investigation of heat transfer and Reynolds number
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
Contents and Nomenclature
DX Coils Contents and Nomenclature Nomenclature... 1 Evaporator Coil Types EN... 2 EF... 2 ER... 2 EJ... 3 EK... 3 Evaporator Construction Connections... 4 Tubing... 4 Headers... 5 Tube Supports... 5 Coil
HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi
HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi 2 Rajesh Dudi 1 Scholar and 2 Assistant Professor,Department of Mechanical Engineering, OITM, Hisar (Haryana)
The soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger
International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 6, Number 1 (2013), pp. 33-40 International Research Publication House http://www.irphouse.com Comparison of Heat Transfer
Experiment 3 Pipe Friction
EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional
A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW. 1998 ASME Fluids Engineering Division Summer Meeting
TELEDYNE HASTINGS TECHNICAL PAPERS INSTRUMENTS A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW Proceedings of FEDSM 98: June -5, 998, Washington, DC FEDSM98 49 ABSTRACT The pressure
FLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
Heat Exchangers. Plate-and-Frame COMPACT HEAT EXCHANGERS PART 1: heat exchangers. Use these design charts for preliminary sizing.
Heat Exchangers COMPACT HEAT EXCHANGERS PART 1: Designing Plate-and-Frame Heat Exchangers Christopher Haslego, Alfa Laval Graham Polley, www.pinchtechnology.com Use these design charts for preliminary
Chapter 8: Flow in Pipes
Objectives 1. Have a deeper understanding of laminar and turbulent flow in pipes and the analysis of fully developed flow 2. Calculate the major and minor losses associated with pipe flow in piping networks
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
HEAT TRANSFER ENHANCEMENT AND FRICTION FACTOR ANALYSIS IN TUBE USING CONICAL SPRING INSERT
HEAT TRANSFER ENHANCEMENT AND FRICTION FACTOR ANALYSIS IN TUBE USING CONICAL SPRING INSERT Rahul M. Gupta 1, Bhushan C. Bissa 2 1 Research Scholar, Department of Mechanical Engineering, Shri Ramdeobaba
Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers
Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers Webinar Q&A This document summarizes the responses to questions posed before and during the webinar on general Heat Exchanger Design
A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS
A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS W. M. Torres, P. E. Umbehaun, D. A. Andrade and J. A. B. Souza Centro de Engenharia Nuclear Instituto de Pesquisas Energéticas e Nucleares
Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"
Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A" Takahiro OUE *1, Kazuto OKADA *1 *1 Refrigeration System & Energy Dept., Compressor Div., Machinery Business Kobe Steel has developed an air-sourced
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations
Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations A.Satyanarayana.Reddy 1, Suresh Akella 2, AMK. Prasad 3 1 Associate professor, Mechanical Engineering
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive
AIR CONDITIONING TECHNOLOGY
AIR CONDITIONING TECHNOLOGY PART 9 Water Cooled Condensers & Cooling Towers IN LAST month s article we looked at how Air Cooled Condensers are used to transfer the total heat of rejection from the air
Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
Engine Heat Transfer. Engine Heat Transfer
Engine Heat Transfer 1. Impact of heat transfer on engine operation 2. Heat transfer environment 3. Energy flow in an engine 4. Engine heat transfer Fundamentals Spark-ignition engine heat transfer Diesel
How To Understand Evaporator
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
Testing methods applicable to refrigeration components and systems
Testing methods applicable to refrigeration components and systems Sylvain Quoilin (1)*, Cristian Cuevas (2), Vladut Teodorese (1), Vincent Lemort (1), Jules Hannay (1) and Jean Lebrun (1) (1) University
16. Heat Pipes in Electronics Cooling (2)
16. Heat Pipes in Electronics Cooling (2) 16.1 Pulsating Heat Pipes 16.1.1Introduction Conventional heat pipe technology has been successfully applied in the last thirty years for the thermal management
Experimental investigation of heat transfer and flow friction in a circular tube fitted with regularly spaced twisted tape elements
Experimental investigation of heat transfer and flow friction in a circular tube fitted with regularly spaced twisted tape elements Smith Eiamsa-ard a, Chinaruk Thianpong b, Pongjet Promvonge b, a Department
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive
Energy savings in commercial refrigeration. Low pressure control
Energy savings in commercial refrigeration equipment : Low pressure control August 2011/White paper by Christophe Borlein AFF and l IIF-IIR member Make the most of your energy Summary Executive summary
1 WATERFLUX - Comparisonon COO 2010-08-17. Rectangular Magmeter in water applications
1 WATERFLUX - Comparisonon COO 2010-08-17 Rectangular Magmeter in water applications Jef Neven KROHNE WATERMETERS $3000 EMF Price C&I (mechanical) water meters Residential water meters $30 Water Metering
Theoretical and Experimental Investigation of Heat Transfer Characteristics through a Rectangular Microchannel Heat Sink
Theoretical and Experimental Investigation of Heat Transfer Characteristics through a Rectangular Microchannel Heat Sink Dr. B. S. Gawali 1, V. B. Swami 2, S. D. Thakre 3 Professor Dr., Department of Mechanical
HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS
HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS P.R.Hatwar 1, Bhojraj N. Kale 2 1, 2 Department of Mechanical Engineering Dr. Babasaheb Ambedkar College of Engineering & Research,
Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts
Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts Imran Quazi#1, Prof. V.R.Mohite#2 #1DPCOE-Mechanical Department, SPP University Pune, India imranqu azi198 [email protected]
Battery Thermal Management System Design Modeling
Battery Thermal Management System Design Modeling Gi-Heon Kim, Ph.D Ahmad Pesaran, Ph.D ([email protected]) National Renewable Energy Laboratory, Golden, Colorado, U.S.A. EVS October -8, 8, 006 Yokohama,
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA [email protected] I K Smith and N Stosic
ME 315 - Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS
ME 315 - Heat Transfer Laboratory Nomenclature Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS A heat exchange area, m 2 C max maximum specific heat rate, J/(s
Keywords: Heat transfer enhancement; staggered arrangement; Triangular Prism, Reynolds Number. 1. Introduction
Heat transfer augmentation in rectangular channel using four triangular prisms arrange in staggered manner Manoj Kumar 1, Sunil Dhingra 2, Gurjeet Singh 3 1 Student, 2,3 Assistant Professor 1.2 Department
Heat exchangers are devices that facilitate the exchange of heat between
cen5426_ch23.qxd /26/04 9:42 AM Page 03 HEAT EXCHANGERS CHAPTER 23 Heat exchangers are devices that facilitate the exchange of heat between two fluids that are at different temperatures while keeping them
Routinely surveying tower overhead vacuum systems can
Troubleshooting crude vacuum tower overhead ejector systems Use these guidelines to improve performance and product quality J. R. LINES AND L. L. FRENS, GRAHAM MANUFACTURING CO. INC., BATAVIA, NEW YORK
A heat pipe heat recovery heat exchanger for a mini-drier
A heat pipe heat recovery heat exchanger for a mini-drier A Meyer Department of Mechanical Engineering, University of Stellenbosch, Stellenbosch R T Dobson Department of Mechanical Engineering, University
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
SECTION 3: CLARIFICATION AND UTILITIES (1)
CHPR4402 Chemical Engineering Design Project The University of Western Australia SECTION 3: CLARIFICATION AND UTILITIES (1) Aaliyah Hoosenally 10428141 TEAM A: ALCOHOLICS ANONYMOUS AALIYAH HOOSENALLY,
Thermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
Enhancement of heat transfer of solar air heater roughened with circular transverse RIB
Enhancement of heat transfer of solar air heater roughened with circular transverse RIB Gurpreet Singh 1, Dr. G. S. Sidhu 2 Lala Lajpat Rai Institute of Engineering and Technology, Moga Punjab, India 1,2
جامعة البلقاء التطبيقية
AlBalqa Applied University تا سست عام 997 The curriculum of associate degree in Air Conditioning, Refrigeration and Heating Systems consists of (7 credit hours) as follows: Serial No. Requirements First
UNIT 2 REFRIGERATION CYCLE
UNIT 2 REFRIGERATION CYCLE Refrigeration Cycle Structure 2. Introduction Objectives 2.2 Vapour Compression Cycle 2.2. Simple Vapour Compression Refrigeration Cycle 2.2.2 Theoretical Vapour Compression
Fired Heater Design and Simulation
Fired Heater Design and Simulation Mahesh N. Jethva 1, C. G. Bhagchandani 2 1 M.E. Chemical Engineering Department, L.D. College of Engineering, Ahmedabad-380 015 2 Associate Professor, Chemical Engineering
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL
WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL Siniša Stojan, Ph.D. student Damir Dražić, Ph.D. student Brodotrogir, HR - 21220 Trogir, Croatia [email protected],
HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS
HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS J.Kalil basha 1,G.Karthikeyan 2, S.Karuppusamy 3 1,2 Assistant Professor, Dhanalakshmi Srinivasan
TITANIUM FABRICATION CORP.
TITANIUM FABRICATION CORP. Titanium, Zirconium, and Tantalum Clad Construction General Considerations In many applications, particularly for large pressure vessels designed for high temperature and pressure,
Building Energy Systems. - HVAC: Heating, Distribution -
* Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center
Lesson 23 Condensers & Evaporators. Version 1 ME, IIT Kharagpur 1
Lesson 23 Condensers & Evaporators Version 1 ME, IIT Kharagpur 1 The specific objectives of this lesson are to: 1. Classify refrigerant evaporators as natural convection or forced convection type, flooded
New Trends in the Field of Automobile Air Conditioning
New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic
PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:
PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name
Solid shape molding is not desired in injection molding due to following reasons.
PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which
DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING
By Philip Sutter Pick Heaters, Inc. DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING INTRODUCTION Many process plants currently use steam or hot water to heat jacketed devices such as tanks,
SIZING AND CAPACITIES OF GAS PIPING
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following
EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT TWIST RATIO OF TWISTED TAPE INSERTS
INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY Vol.33 (2015), No.3, pp.158-162 http://dx.doi.org/10.18280/ijht.330324 EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT
Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.
Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials. Attachment C1. SolidWorks-Specific FEM Tutorial 1... 2 Attachment C2. SolidWorks-Specific
How To Calculate The Performance Of A Refrigerator And Heat Pump
THERMODYNAMICS TUTORIAL 5 HEAT PUMPS AND REFRIGERATION On completion of this tutorial you should be able to do the following. Discuss the merits of different refrigerants. Use thermodynamic tables for
Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal
Technical Bulletin By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal SUMMARY Refrigeration air coolers (evaporators)
MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems
Abstract Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems M. Jaradat, R. Heinzen, U. Jordan, K. Vajen Kassel University (Germany), Institute
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
INTRODUCTION TO. Chapter 15
INTRODUCTION TO HEAT EXCHANGERS Chapter 15 What is a Heat Exchanger? A heat exchanger is a device that is used to transfer thermal energy (enthalpy) between two or more fluids, between a solid surface
Storm Drainage Systems 11.9-1
Storm Drainage Systems 11.9-1 11.9 Gutter Flow Calculations 11.9.1 Introduction Gutter flow calculations are necessary in order to relate the quantity of flow (Q) in the curbed channel to the spread of
Secondary Heat Transfer Systems and the Application of a New Hydrofluoroether
Secondary Heat Transfer Systems and the Application of a New Hydrofluoroether Greg Sherwood, P.E. 3M Engineering Fluids and Systems Specialty Chemicals Division St. Paul, Minnesota A great deal of effort
Fluid Mechanics: Static s Kinematics Dynamics Fluid
Fluid Mechanics: Fluid mechanics may be defined as that branch of engineering science that deals with the behavior of fluid under the condition of rest and motion Fluid mechanics may be divided into three
Understanding Plastics Engineering Calculations
Natti S. Rao Nick R. Schott Understanding Plastics Engineering Calculations Hands-on Examples and Case Studies Sample Pages from Chapters 4 and 6 ISBNs 978--56990-509-8-56990-509-6 HANSER Hanser Publishers,
Refrigeration Compressed Air Dryer Buran Ultrapulse
Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of
cmn_lecture.2 CAD OF DOUBLE PIPE HEAT EXCHANGERS
cmn_lecture.2 CAD OF DOUBLE PIPE HEAT EXCHANGERS A double pipe heat exchanger, in essence, consists of two concentric pipes, one fluid flowing through the inner pipe and the outer fluid flowing countercurrently
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there
Pressure drop in pipes...
Pressure drop in pipes... PRESSURE DROP CALCULATIONS Pressure drop or head loss, occurs in all piping systems because of elevation changes, turbulence caused by abrupt changes in direction, and friction
THE PSYCHROMETRIC CHART AND ITS USE
Service Application Manual SAM Chapter 630-16 Section 3A THE PSYCHROMETRIC CHART AND ITS USE Psychrometry is an impressive word which is defined as the measurement of the moisture content of air. In broader
EXPERIMENTAL STUDIES ON PRESSURE DROP IN A SINUSOIDAL PLATE HEAT EXCHANGER: EFFECT OF CORRUGATION ANGLE
EXPERIMENTAL STUDIES ON PRESSURE DROP IN A SINUSOIDAL PLATE HEAT EXCHANGER: EFFECT OF CORRUGATION ANGLE B. Sreedhara Rao 1, Varun S 2, MVS Murali Krishna 3, R C Sastry 4 1 Asst professor, 2 PG Student,