white paper Ferrules: Your Best Insurance Against Costly Connection Failure Executive Summary
|
|
|
- Garey Stephens
- 10 years ago
- Views:
Transcription
1 Ferrules: Your Best Insurance Against Costly Connection Failure white paper Executive Summary Thanks to its superior flexibility, longer flex life*, and resistance to vibration, insulated stranded wire is the ideal choice for most panels. From both a physical and electrical perspective, however, bare stranded wire is a poor choice for connections. Stripped of its insulation, stranded wire quickly loses the coherence that provides its strength and resiliency. Once it begins to unravel, it is subject to breakage and corrosion that can produce overheating, short circuits, and connection failure, as well as cause serious safety issues. Ferrules can rectify this situation by giving stranded wire the qualities of solid wire where it is needed most, at the point of connection. Ferrules significantly simplify installation, improve safety, and diminish the risk of costly panel failure. This white paper highlights the advantages of ferrules for electrical connections and includes guidelines for their selection and purchase. There s Strength in Numbers Stranded wire is the wire of choice for most electrical applications. Due to its superior flexibility and longer flex life, it offers more routing options than solid wire. Stranded wire is also more durable. It stands up to vibration and sudden movement that can cause rigid solid wire to snap. Stranded wire gains its flexibility from the way the bundles of wire in the strands are woven together. The integrity of the stranded bundles is further reinforced by the jacket of insulating material that surrounds them. The moment the insulation is stripped from the wire-end, however, its strength is transformed into a source of weakness as wire bundles unravel and individual strands are exposed. In the process, the potential for short circuits and failed connections rises dramatically. Identifying shorts is a time-consuming process. In case of a typical panel, this could mean testing hundreds of connections, causing extensive downtime. A Bare Connection Yields Bare Bones Results With stranded wire, the old adage applies: the whole is indeed greater than the sum of its parts. The reverse, unfortunately, is also true. Once the insulation is removed and stranded wire begins to unravel, ease of installation is sacrificed as well as the long-term electrical performance, durability and safety of the connection. Installation The problems with bare stranded wire connections begin the moment the stripping tool is put down and an attempt is made to place the bare end of the stranded wire into the terminal compartment. If care is not taken, the wire will begin to splay, making installation painstaking and time-consuming. If the unraveling wire is successfully inserted into the terminal block, it is unlikely that the full electrical efficiency of the connection will be realized. If the strands have fanned out, not all of them will make contact with the connector and be available to conduct current. Furthermore, the individual strands, once isolated, can break easily. This is particularly an issue when stranded wires are used with spring clamp connectors. * Flex life refers to a cable or wire s resistance to stress, from repeat bending.
2 Long-Term Electrical Performance Stripping the insulation and exposing the stranded wire to air also undermines the long-term electrical performance of the connection. Weidmuller technicians conducted a series of test using a Weidmuller SAK 4 screw terminal and a Weidmuller AWG 12 ferrule in a climate-controlled cabinet. Over time, corrosion of the unprotected stranded wire produces an increase in contact resistance, as Figure 1 shows. As the contact resistance rises, the temperature inside the connection increases, leading to higher current flow. Above 0.43 mω, this can lead to losses of insulation, short circuits, and burning within the panel. In a salty environment, contact resistance of stranded wire approaches its limit even more quickly, as Figure 2 demonstrates. Uninsulated stranded wire extending out of the terminal block can also increase leakage and creepage distances. Excessive leakage and creepage can heat up the connection and cause short circuits. Durability Under normal conditions, stranded wire provides superior vibration resistance compared to solid wire, based on way the strands are woven together. When stranded wire is stripped, the exposed bundles of strands lose their coherence and begin to separate. When subject to vibration, these individual strands are susceptible to loosening the connection or breaking. In addition, strands can easily break when bent or stressed. In either case, the result is decreased current flow and, eventually, failed connections. Safety Taken together, using bare stranded wires at the point of connection not only degrades system performance, but also poses significant safety risks. Higher temperatures, short-circuits, and, in some cases, arc flashes can result, endangering personnel as well as equipment. 1 The results of the Standard Environment test are shown in Figures 1 and 3. They were performed using average temperature and humidity in Detmold, Germany. The results of the Salty Environment tests are shown in Figures 2 and 4. They were performed using the average temperature and humidity of the Sylt Island of the North Sea. Page 2
3 Ferrules Making a Solid Connection During the 1960s, engineers realized that one way to overcome the deficiencies of bare stranded wire at the point of connection was to give the exposed section the virtues of solid wire. They did this by encasing it in a tin-plated soft-electrolyte copper (E-CU-57) ferrule, which is crimped in place. Over the years, ferrule technology has been improved. In the 1970s, ferrules were introduced with a plastic conical cable entry, providing added safety and durability. In the 1990s, twin ferrules, allowing for the simultaneous insertion of two wireends, were invented, and DIN was adopted to standardize the sizes, dimensions, and testing of ferrules. As shown in the illustration, the conductor insulation must be pushed into the plastic collar, and the conductor should completely fill the ferrule sleeve. Depending on cross-section, the conductor should protrude as much as 0.5 mm from the ferrule sleeve. An Efficient Use of Time and Resources Ferrules are required in Europe for CE certification and it is easy to understand why. They enable users to take advantage of the features of stranded wire without the problems caused by a bare-wire connection. The few seconds required to apply a ferrule to the wire-end are more than made up by the ease of insertion. Because the ferrule completely encases the stranded wire, the quality of the connection is far superior, and there is no possibility that the wire can break, even when used with tension clamps. No matter how many times the wire is removed and reinserted, the ferrule retains its shape and integrity. The long-term electrical performance is also higher because ferrules, applied with the proper crimping tool, form a gas-tight* connection shielding the wire from corrosion even in a salty environment. Analysis shows that stranded wire with ferrules demonstrate resistance over time that is similar to solid wire, as Figures 3 and 4 illustrate. * Gas tight refers to the ability of air or gasses to permeate a connection Page 3
4 In addition, ferrules with plastic collars reduce leakage and creepage values as well as gas intrusion. This is particularly important in components like PLCs, where connection density is important. Stranded wire-ends protected by ferrules are also much more resistant to vibration and breakage at the connection. In effect, ferrules produce a much more efficient and durable connection than can be attained with bare stranded wire which results in significant savings over the life of the system. The standard size ferrule for a 16 AWG wire typically costs $0.05. If there are 1,000 connections in a panel, the total cost is $50. That is a fraction of what downtime, testing, repair, and replacement costs can run in the event of a short circuit. Most important, ferrules also provide a critical margin of safety for operators, reducing the potential for shorts and arc flashes. Sourcing Ferrules Wisely Although ferrules might seem like a commodity product, they are not. When you source ferrules, it is critical to select a supplier whose ferrules go beyond the immediate advantage of simplified installation to provide an efficient, durable, and safe connection over the long term. Accordingly, when specifying or purchasing ferrules, keep the following guidelines in mind: Choose a manufacturer who adheres to the DIN standard. This standard describes the allowable dimensions and tolerances of the plastic collar and metal sleeve, ensuring the quality of the connection. The crimped connection is subject to a pull-out force test calibrated to the cross section of the wire. In addition, it provides a uniform color-coding system for ferrules with plastic collars, with a specific color for every cable cross section. Thanks to this system, users can immediately recognize different cables, minimizing confusion and increasing operational safety. Select a manufacturer whose ferrules have UL approval. This is particularly important when using ferrules in UL-certified panels. All UL 508 panels must use UL-listed components. Choose a manufacturer who offers crimping tools and contacts that are designed to work together, a recommendation contained in UL 508 and DIN EN Equally important, select a manufacturer who has subjected its crimping tools, ferrules and connection systems to rigorous testing. These tests should include gas intrusion, vibration, bending, and longterm connectivity testing, as well as pull-out tests for screw and tension clamps and for innovative connection technology like push-in connectors. Make your purchases from a manufacturer who offers a broad range of crimping shapes (including trapezoidal, trapezoidal indent, square, and hexagonal shapes), ferrules (with and without plastic collars as well as twin ferrules), terminal blocks, and other devices so that you can return to the same supplier for all your connection needs and maintain a consistent quality standard. Standards-Based Crimping in an Unequaled Range of Shapes and Sizes Our goal at Weidmuller is to support our customers and partners around the world with products, solutions and services that truly serve their needs. As a result, we have taken pains to ensure that our crimped connections meet DIN and UL standards, and we have committed ourselves to producing ferrules in a wide range of sizes, color codes, and configurations, as well as crimping tools that produce an unsurpassed assortment of shapes. Meeting Industry Standards At Weidmuller, our approach to ferrules and crimping tools is straightforward: by adhering to industry standards, we add value for our customers. For instance, we subject ferrules crimped with Weidmuller tools to pull-out force tests, as required by DIN During the test, we pass the crimped conductor through a perforated template firmly clamped to a pull-out force testing machine. We then apply a steady tensile force for one minute. The pull-out forces that Weidmuller crimped ferrules withstand are enumerated in DIN EN part 1: Page 4
5 DIN Pull-Out Force Testing Cross section sq. mm AWG Pull out force N Weidmuller also produces ferrules with collars that have been approved and listed by UL as conforming to the requirements of UL508 and DIN EN when crimped properly with Weidmuller crimp tools. There is no UL listing currently for ferrules, so UL uses the UL 486A standard for wire connectors and soldering lugs for use with copper conductors. All Weidmuller ferrules are UL listed from AWG 24 up to AWG 1 (with exception of AWG 2). The connectors are tested with a direct pull for one minute and withstand the following pull-out forces: UL Pull-Out Force Testing Cross section sq. mm AWG Pull out force N Pull out force pound These tests using Weidmuller crimping tools are certified by an UL-approved source regularly (usually on an annual basis). Weidmuller takes its testing one step further. In addition to testing ferrules and crimping tools to meet DIN and UL standards, we test them with the connection technologies including screw clamp, tension clamp, and push-in connection that are part of our Connectivity, DC, and electronic products. Our goal is to ensure a strong, durable, safe connection for customers regardless of their needs. The Ultimate Source for Crimping Shapes The strength of Weidmuller crimped connection is a direct consequence of the design of our crimping tools. They feature an integral ratchet mechanism with a disengaging option to produce optimum processing quality. Another way we serve our customers is to offer crimping tools in an unsurpassed range of shapes. In this way, customers can choose the right shape for a specific application. Page 5
6 Weidmuller Crimping Shapes and Crimping Tools Trapezoidal Crimp Trapezoidal Indent Crimp Square Crimp Hexagonal Crimp PZ 6 Roto PZ 6/5 PZ 3 PZ 6 Hex A Comprehensive Range of Ferrules Because we believe that ferrules offer unmatched advantages for stranded wire connections, we produce ferrules in a variety of shapes and configurations: Wire end ferrules with plastic collar from AWG 26 to 300MCM Wire end ferrules with plastic collar on reels for automatic machines from AWG 22 to 14 Strips of wire end ferrules with plastic collars for stripax plus 2.5 from AWG 20 to 14 Wire end ferrules for earth- and short-circuit-proof cable with a bigger plastic collar Twin ferrules for the connection of two wires from AWG 20 to 6 Wire end ferrules without plastic collars from AWG 24 to 350 MCM In addition, Weidmuller provides a full range of ferrules adhering to the DIN standards in three color codes (Weidmuller, DIN 46228, and other ). The Cost-Efficient Approach to High-Quality Connections The use of ferrules is one of the most obvious signs of a panel that is carefully designed and built. Its neat appearance, however, is ultimately a reflection of value gained by containing stranded wire at the point of connection. As such, the use of ferrules indicates a prudent allocation of resources. The incidental expense of ferrules and the time it takes to crimp them to the end of a wire pale in comparison to the delays and substantial costs of shorts and failed connections that occur when stranded wire frays or breaks. Simply put, by enabling high-quality, long-term connections, ferrules are the cost-efficient choice. Page 6
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
picomax The Pluggable Connection System
picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable
WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS
CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
Universal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
By Jim Dunbar Product Manager, Terminals & Splices and Tom Michielutti, Senior Product Engineer, Tyco Electronics, Harrisburg, PA
Electrical Terminals By Jim Dunbar Product Manager, Terminals & Splices and Tom Michielutti, Senior Product Engineer, Tyco Electronics, Harrisburg, PA Insulated and non-insulated closed barrel electrical
AMP Standard Terminals and Splices. RoHS. Ready
AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control
XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement
Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Waterproof Connectors for Outdoor Use
Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight
Powermate Range Pitch 7.62
owermate Range itch 7.62 in headers Socket connectors CB connection Solder connection SV 7.62/90 500 V / 43 A SV 7.62/180 500 V / 41 A.2.4 Cable connection Clamping yoke connection Tension clamp connection
Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4
This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable
ZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Power Supply Cables and Connectors
Power Supply Cables and Connectors Often during the excitement of designing a challenging new system, some of the more mundane engineering aspects get overlooked. This is especially true of connections
5.2. Overview. The better method to install solderless compression connectors on power cable
5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
DVD-60C The Seven Sins of Wire Harness Assembly
DVD-60C The Seven Sins of Wire Harness Assembly Below is a copy of the narration for DVD-60C. The contents for this script were developed by a review group of industry experts and were based on the best
HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING
HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING There are several ways to wire multiple batteries to achieve the correct battery voltage or capacity for a particular DC
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior
This presentation to be used in conjunction with:
1 This presentation to be used in conjunction with: Spec Sheets: SA-GRSP10, SA-GRSP09, SA-GRSP11 Samples in DC-GROUND-KIT 8/16/2012 2 Network Bonding and Grounding: TIA-607-B Generic Telecommunications
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials
VDE Information General Information The voltage which can be applied to a terminal depends on the relevant regulations, the installation conditions and, of course, the dimensions and insulating materials
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
Cable management for rack-mounted systems
Cable management for rack-mounted systems technology brief, 2 nd edition Abstract... 2 Introduction... 2 Cable routing guidelines... 3 Separation of power and data cables... 3 Retention of excess cable...
Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes
BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can
East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE
SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders,
ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
Key Design Criteria for High Flex Cable Constructions By Mike Levesque, Dale S. Long, and Ron Crouch of C&M Corporation
KeyDesign CriteriaFor HighflexCable Constructions Key Design Criteria for High Flex Cable Constructions By Mike Levesque, Dale S. Long, and Ron Crouch of C&M Corporation With the continued growth of factory
The range of rail-mounted terminal blocks. for a perfect electrical installation.
The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal
14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
The Don ts of Better Flexible Circuit Design and Manufacture By Mark Finstad Friday, 01 June 2007
The Don ts of Better Flexible Circuit Design and Manufacture By Mark Finstad Friday, 01 June 2007 Successful designs are soon forgotten but failures are remembered for years. Steering clear of these twelve
R&Mfreenet Advanced Cat 6 A Unshielded Connection Module
R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions
Feed-through terminal block - SSK 110 KER-EX - 0502058
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
ZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
THE 7 SINS OF WIRE HARNESS ASSEMBLY TRAINING CERTIFICATION TEST (DVD-60C)
This test consists of twenty multiple-choice questions. All questions are from the video: The 7 Sins of Wire Harness Assembly (DVD-60C). Each question has only one most correct answer. Circle the letter
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
Errors Related to Cable Resistance Imbalance in Three Wire RTDs
Errors Related to Cable Resistance Imbalance in Three Wire RTDs 1.0 Introduction There are multiple sources of error that can impact the accuracy of an RTD measurement. The cable incorporated into the
Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?
Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059? Speaker: Wolfgang Sichmann, Product Manager PCB Plug-In Connectors,
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting
User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01)
User s Manual BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide (60-073-01) BNC Termination Kit Instructions This document is a compilation of Extron s instructions, together with
SMD Terminal Blocks with Push-Buttons
SMD Terminal Blocks with Push-Buttons SMD Terminal Blocks Small is Big WAGO s new SMD Terminal Blocks provide push-button termination for conductors 0. 0.75 mm/awg 4 18 (060 Series) and 0.5 1.5 mm/awg
Installation instruction CASAFLEX - Connecting piece DN 100
1 CASAFLEX - 11 10 114,3 x 4,5 3 5 2 4 1 7 6 8 12 9 Do not begin work until you have read the installation instruction carefully. 1 internal backing sleeve 2 graphite packing 3 connecting piece 4 thrust
AS COMPETITION PAPER 2007 SOLUTIONS
AS COMPETITION PAPER 2007 Total Mark/50 SOLUTIONS Section A: Multiple Choice 1. C 2. D 3. B 4. B 5. B 6. A 7. A 8. C 1 Section B: Written Answer Question 9. A mass M is attached to the end of a horizontal
U-shaped Micro Photoelectric Sensor
SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection
White paper SACE Tmax XT Circuit-Breaker Terminals and Connection Circuit-Breaker Terminals and Connections Index Introduction... 2 1. Components used for wiring... 3 1.1. Electrical...3 1.2. Flexibility
Instruction Manual. Cable Splicing. Models 4500-9, 4500-9-HDF1, 4500-9-HDF2 4500-9-SS1
Instruction Manual Cable Splicing Models 4500-9, 4500-9-HDF1, 4500-9-HDF2 4500-9-SS1 No part of this instruction manual may be reproduced, by any means, without the written consent of Geokon, Inc. The
INFO. Crimping pliers
for end sleeves When crimping end sleeves a distinction is made between sleeves with and without plastic collars and between trapezoid, square and hexagon pressing. The sleeves with a plastic collar make
HARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION
ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION by Richard Laney Introduction Elevator traveling cable is a vital link between the elevator car and controller. In conventional elevators, all power and signal
Assembly Instruction CAI- Connector with universal Endbell
CANNON STANDARD Seite 1 von 17 CAI- Connector with universal Endbell Shell size 10 to 36 with APK contact / Trident T2P - contact Illustration and assembly exemplary of CAI Layout 20-0306 with APK / Trident
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
Spring Cage Feed-Through Terminal Blocks ST
Spring Cage Feed-Through Terminal Blocks ST The product family ST with the new spring cage system "mini spring" is extremely space-saving. Space is saved thanks to a clearly smaller spring system without
RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)
Triple T Broadband Public Co., Ltd. Outside Plant Standard Sector Specification No. OES-001-027-04 Issued: RE-ENTERABLE SPLICE CLOSURE KITS (For Air Core None Pressurized Cable) 1. SCOPE 1.1. This specification
Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
HARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
TBM5, TBM5-S and TBM5-SV
TBM5, TBM5-S and TBM5-SV Compression Tool Instructions Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Table of Contents 1.0 Operating
3M Wire Connectors. Reliable, high performing solutions for every wire connecting application. 3Innovation
3M Wire Connectors Reliable, high performing solutions for every wire connecting application. 3Innovation SAVE TIME, REDUCE INVENTORY YOU CAN NEVER BE TOO WELL-CONNECTED ON THE JOB The best connectors
Panduit 28 AWG Patch Cords Installation Guideline
Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure
Fault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
EPIC CIRCON M23 Series Circular Signal Connectors
Circular Signal Connectors CIRCON M2 circular signal connectors are designed to DIN specification N698 and have a standard M2 threaded connection housing. They are offered in coupler, connector, and panel
Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs
Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs By Gordon Busch Product Marketing Industrial Connection Technology Phoenix Contact GmbH & Co. KG Blomberg, Germany Executive Summary
Trapezoidal-Connectors Series TMC
Trapezoidal-Connectors Series TMC Subminiature-D Connectors to DIN 41 652/IEC 807-3 General Series TMC connectors are available in 5 different housing sizes with 9, 15, 25, 37 and 50 pins. In applications
Copper and Aluminum busbars
Copper and Aluminum busbars Two metals are currently used as conductors in electric panel boards: copper and aluminum In particular, when in need to define a power distribution inside an electric panel
270526-TC Grounding and Bonding for Telecommunications Systems
270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General Related Documents The following related sections of the OT standards shall also be applicable to this section. OT Engineer
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics
SERIES HPQN CONNECTORS DESCRIPTION CONTENT Designed by James Qu at Anoison in 2006, the HPQN is a quick locking version of the widely used type N connector. By replacing the threaded interface of the original
Product Information. HMC 6 Hybrid Motor Cable
Product Information HMC 6 Hybrid Motor Cable November 2014 HMC 6 Single-cable solution for servo drives Motors normally need two separate cables: One cable for the motor encoder One cable for the motor
Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
Field Installable Optical Connector for Cables
Field Installable Optical Connector for Cables Daigo Saito 1, Kazuhiro Takizawa 1, Kazuya Ogata 1, and Tan Khee Yen Serin 2 With the rapid expansion of fiber to the home (FTTH) in Japan, mechanical splices
Cat7/Class F New Installation Concept New infrastructure. Handbook
Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM
Pyrotenax SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM Contents Introduction This section provides an overview of general circuit design considerations and installation guidelines for a Pyrotenax System
Arktite Heavy Duty Circuit Breaking Plugs and Receptacles
1312-1313.qxp 12/16/2013 7:04 PM Page 1312 Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Features: Arktite circuit breaking plugs and receptacles are
FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS
Product Range ROUND STRANDED COPPER CABLE Electrolytic Copper / Oxygen Free Copper Conforms to DIN 46438 Standards Finish: Bare Copper / Tinned / Silver-plated ROUND BRAID / ROUND STRANDED CABLE WITH OVERALL
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
Subminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel
CHAPTER 4 UTILITY SYSTEMS ELECTRICAL Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc. Abstract The technology for connecting lead and magnet wires for electric motors and electro mechanical devices
Crimp Tooling Where Form Meets Function
Crimp Tooling Where Form Meets Function Quality, cost, and throughput are key attributes for any production process. The crimp termination process is no exception. Many variables contribute to the results.
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
