1 REQUEST FOR PROPOSALS COURT OF APPEAL, 4TH APPELLATE DISTRICT, DIVISION 2 REGARDING: RFP TITLE: RFP NUMBER: PROPOSALS Due: MECHANICAL AND HVAC INSPECTION AND PREVENTIVE MAINTENANCE Inspection and preventive maintenance services for the Court of Appeal, 4th Appellate District Division th Street, Riverside, CA /2 RFP 13/14-06 FEBRUARY 24, 2014, BY NO LATER THAN 4:00 P.M., (PACIFIC TIME) Page 1 of 13
2 1.0 Description of Services and Deliverables The Court of Appeal, Fourth Appellate District, Division Two (Court) seeks the services of a person or entity with expertise in Mechanical and HVAC Systems. The court requires a qualified service provider to provide inspections and preventive maintenance to improve equipment operations, increase efficiency, minimize breakdowns and prolong equipment life and to perform scheduled inspections of the Court s systems for a one year period, with two one-year options. The maintenance also includes filter service, water treatment service, and outdoor coil cleaning service. The Service Provider will provide: 1.1 Mechanical and HVAC Inspections: Visit the Court on a routine schedule to perform inspection tasks on the HVAC system that includes the following, as applicable: Coils Heat Exchangers Condensate Drain Compressor Operations Refrigerant Piping Oil Levels Motor Operations Bearings Water Levels Voltage and Amp Draws Belts and Pulleys Fans/Blades Refrigerant Charge Blowers Reversing Valves Cabinets and Ductwork Operating/Safety Controls Electrical/Relays and Contactors at Equipment 1.2 Preventive Maintenance Actions: During scheduled inspections visits, provide proactive, hands-on maintenance services to improve equipment operations, increase efficiency, minimize breakdowns and prolong equipment life. Services may include but are not limited to: Fan Blade/Blower Cleaning Bearing Lubrications Motor Lubrications Safety Control Adjustments Coil Cleaning Condensate Drain Cleaning Belt Adjustments/Replacements Calibrations Oil Analysis Operating Control Adjustments Equipment Cleaning Refrigerant Charge Adjustments 1.3 Filter Service/Changes: These services/changes will be scheduled at a frequency designed for best operating conditions and overall value to the Court. Type and frequency of service to be determined base on observed and expressed needs. Filter service to be included per schedule: 1. Removal and proper discard of used filters/medias 2. Provide and deliver to Court replacement filters/medias 3. Install Filters 4. Wash Filters as required and as applicable 1.4 Water Treatment Service: Service Provider will conduct scheduled visits to test, analyze and adjust water treatment levels as applicable. This Service is to include the chemicals required to maintain levels Page 2 of 13
3 within industry specifications as well as calibrations and operational testing of existing treatment equipment. 1.5 Outdoor Coil Cleaning Service: This service will improve efficiency and contribute to a longer coil and equipment life. The Service Provider is to use environmental and equipment safe cleaning agents to outdoor coil surfaces and rinse with pressured water. 2.0 SERVICES: Type of Service Frequency Preventive Maintenance Actions AC Units 4 Annual Maintenance on AC Units 1 Pre-Filter Service TYPE: TriDim 60% Efficient Panel Links 4 Andover DDC Controls Maintenance Per DDC Schedule Water Treatment Service on Hot Water Boiler Monthly Outdoor Condenser Coil Cleaning Service 7 Hot Water Boiler Maintenance 3 Hot Water Boiler Annual Maintenance 1 Hot Water Pump & Expansion Tank Maintenance 4 Infrared Electrical Panel Testing Annually Final Filter Service TYPE: TriDim 98% Efficient Cubes Annually Variable Frequency Drive Maintenance Annually Belt Replacement on AC and Exhaust Fans Annually Computerized Documentation Annually 2.1 List of Covered Equipment: Unit # Make Model Serial Size Type AC 1 Trane SXFC7540P88E9AD8F01T8 J98D Ton AC 2 Trane SXFC7540P88E9AD8F01T8 J98D Ton AC 1 VFD-1 AC 1 VFD-2 AC 2 VFD-1 AC 2 VFD-2 ACC-1 (Serves Rm-116) ABB ABB ABB ABB 40 HP 20 HP 40 HP 20 HP Trane TTA072C/400A 6 Ton Package Unit; Rooftop Box Car Package Unit; Rooftop Box Car Variable Speed Drive Variable Speed Drive Variable Speed Drive Variable Speed Drive Condensing Unit; Air Cooled Page 3 of 13
4 Unit # Make Model Serial Size Type FC-1 Rm-116 Trane TEW060AO 6 Ton Fan Coil B-1 Raypak Space Heating Water BTU Water B-2 Raypak Domestic Water 500,000 BTU Boiler; Hot Water ET1 Space Heating HW 30 Gal Boiler; Hot Water P-1 Space Heating HW 1.5HP Circuit Pump P-2 Space Heating HW 1.5 HP Circuit Pump P-3 Space Heating HW Fractional Circuit Pump EF-1 Carnes VEBK18P1A14A20SPCI Fractional Fan; Exhaust EF-2 Carnes VEBK18P1A14A20SPCI Fractional Fan; Exhaust A-1 Andover Automation Controls Controls: DDC 2.2 BOILERS 1. Inspect fireside of boiler and record condition (annually). 2. Brush soot and dirt from combustion chamber (annually). 3. Inspect firebrick and refractory for defects (annually). 4. Visually inspect boiler pressure vessel for possible leaks and record condition. 5. Visually inspect expansion tank and adjust as required. 6. Disassemble, inspect and clean low-water cutoff (annually). 7. Check hand valves and automatic feed equipment. Repack and adjust as required. 8. Inspect, clean and lubricate the burner and combustion air equipment (annually). 9. Check fuel piping for leaks and proper support. 10. Check burner sequence of operation and combustion air equipment. 11. Review manufacturer s recommendation for boiler and burner start-up. 12. Check fuel supply. 13. Check auxiliary equipment operation. 14. Inspect burner, boiler and controls prior to start-up. 15. Start burner and check operating controls. 16. Test safety controls. 2.3 PACKAGED VARIABLE AIR VOLUME SYSTEMS (TRANE ROOF TOP PACKAGED AHU) 1. Review manufacturer s recommendation for start-up. 2. Energize crankcase heater per manufacturer s recommendation for warm-up. 3. Visually inspect for leaks. 4. Inspect operation of hot gas by-pass. 5. Inspect electrical connections, contactors, relays, and operating/safety controls. 6. Check vibration eliminators. Replace or adjust when authorized. 7. Check compressor oil level. Change oil and refrigerant filter drier when authorized. 8. Check and test all operating and safety controls. 9. Inspect operating temperatures and pressures. 10. Check fan assembly. Page 4 of 13
5 11. Lubricate fan bearings per manufacturer s recommendations. 12. Lubricate motor bearings per manufacturer s recommendations. 13. Check belts and sheaves. Adjust as required and replace (annually). 14. Tighten all nuts and bolts. 15. Check motor mounts and vibration pads. Adjust as required. 16. Check motor operating conditions. 17. Lubricate and adjust associated dampers and linkage and controls. 18. Check fan operation. 19. Check VFD for proper operation. 20. Clean outside air intake screen. 21. Check and clean drains and drain pans. 22. Inspect filters. Change per schedule. 23. Check heating and/or cooling coils. 2.4 EXHAUST FANS 1. Inspect belts, adjust as required and replace (annually). 2. Lubricate motor and bearings as required. 3. Inspect starters, disconnect and clean contacts. 2.5 CONDENSING UNITS AIR COOLED 1. Review manufacturer s recommendation for start-up. 2. Energize crankcase heater per manufacturer s recommendation for warm-up. 3. Visually inspect for leaks. 4. Inspect electrical connections, contactors, relays, and operating/safety controls. 5. Check vibration eliminators. Replace and adjust when authorized. 6. Check compressor oil level. Change oil and refrigerant filter drier when authorized. 7. Check and test all operating and safety controls. 8. Check operating conditions. Adjust as required. 2.6 FAN COIL UNITS 1. Inspect motor. Clean and lubricate. 2. Lubricate fan bearings. 3. Inspect coil(s) for leaks dependent on accessibility. 4. Inspect drain pan or pipe and clean as required. 5. Inspect belt, adjust tension and replace (annually). 6. Test operation unit internal on-off switch. 7. Change filters per filter schedule. 2.7 PUMPS 1. Lubricate pump bearings per manufacturer s recommendations. 2. Lubricate motor bearings per manufacturer s recommendations. 3. Tighten all nuts and bolts. Check motor mounts and vibration pads. Replace and adjust when authorized. 4. Visually check pump alignment and coupling. 5. Check motor operating conditions. 6. Inspect electrical connections and contactors. 7. Check and clean strainers and check hand valves (annually). 8. Inspect mechanical seals. Inspect pump packing. Page 5 of 13
6 9. Verify gauges for accuracy. 2.8 WATER TREATMENT HOT WATER BOILER 1. Provide, deliver and administer chemicals that have a history of proven results, designed to inhibit scale formation, corrosion and biological growth. 2. Provide monthly analysis of the water conditions, via on-site testing, accurately interpreting the results, making immediate adjustments and recommendations in order to meet industry standards. 3. Provide a visual inspection of the equipment and make a written recommendation of upgrades to help minimize energy and water usage. 2.9 VARIABLE FREQUENCY DRIVES 1. Inspect and tighten all nuts, bolts, and retaining devices on mechanical assemblies and mounting brackets. 2. Verify all electrical connections are at proper torque settings. 3. Clean/change all cooling filters and grills if applicable. 4. Remove all dirt and dust that has penetrated the unit interior or accumulated on the processor boards using high-pressure nitrogen. 5. Verify and record all inverter settings. 6. Verify all internal power supplies and all logic outputs. Record as applicable. 7. Check proper operation of DC buss capacitors. 8. Check all external controls related to the operation of the inverter. 9. Provide recommendation for repair, parameter changes, etc. in writing INFRARED ELECTRICAL PANEL TESTING 1. Provide up to sixteen hours of Infrared Electrical Panel Testing (annually). 2. Provide reports with recommendations. 3. Make drawing panel list for report. 3.0 BUILDING AUTOMATION CONTROLS (DDC) MAINTENANCE TASKS 3.1 Refer to DDC schedule for number of visits and hours per year that will be provided to accomplish the following: 1. Software maintenance, file maintenance and backups (on-site and remote) and system optimization. 2. Control sequence evaluation, modification and enhancement. 3. Historical log review. 4. Field sensor verification and calibration spot checks. 5. Hardware communication tests and functional verification. 6. Control program and loop evaluation, modification and enhancement. 7. Service Provider will be available for extra calls on a daily basis, five days per week, Monday through Friday during standard work hours. 8. Response time to any after-hours request is to be within four hours. 9. Remote dial-up technical support for up to four hours per year. 10. Excludes all wiring and conduit systems. Page 6 of 13
7 Because the Court has Andover equipment, the court s preference is for a contractor who is Andover certified with a minimum of five (5) years experience and an Andover dealer. In addition, the contractor must include a variable speed drive division for the inverter maintenance. Please state in your proposal whether you: 1) are/ are not Andover certified with a minimum of five (5) years experience; and/or 2) are/ are not an Andover dealer; and 3) have a variable speed drive division. 3.2 DDC CONTROLS TECHNICAL SUPORT The scope of services outlined below is a guide, not a limit of duties or obligations, as the intent of the agreement is to provide a comprehensive DDC Controls Technical Support and Maintenance Program as described herein. DDC Equipment to Be Serviced: Manufacturer Quantity B4920 Andover Bacnet controller. 1 B3885 Andover BACnet VAV Controllers 38 B3865 Andover BACnet VAV Controllers 37 Smart Sensors 37 Dumb Sensors 38 Andover Cyberstation 1 Infilinks SERVICES NOT INCLUDED 4.1 Maintenance, repair or replacement of non-maintainable parts of the equipment included in the List of Covered Equipment such as, but not limited to, unit cabinets, insulating materials, electrical wiring, structural supports and other non-moving parts. 4.2 Replacement of the equipment included in the List of Covered Equipment, or if repairs are required because of vandalism, flooding, fire, lightning, roof leaks, power failure, installation of incompatible equipment, improper operating procedures, improper/inadequate water treatment or filter service not provide by the Service Provider or by any other cause beyond the control of the Service Provider. 4.3 Any and all additional items or equipment required by any governmental authority, insurance company or other, and not specifically set forth in the List of Covered Equipment and Services. 4.4 Except as may be specifically included in Services, the Service Provider shall not be responsible or obligated to provide service with respect to the following: 1. Piping other than refrigerant piping. 2. Damage due to freezing weather or corrosion of equipment. Page 7 of 13
8 3. All non-moving parts such as pressure vessels, tubes, cabinets, casings, door seals, floor drains, thermometers, gauges, flues, ductwork, grilles, heat transfer tubes and coils, refractories, oil or gas heat exchangers, fan housings, structural support. 4. Valves. 5. Electrical supply, disconnect switches, circuit breakers. 6. Monitoring/Recording devices affixed to equipment. 5.0 WORK LOCATION AND HOURS Service Provider will provide its mechanical maintenance and automation maintenance of the equipment located at 3389 Twelfth Street, Riverside, CA and set forth on the List of Covered Equipment provided for in this Request for Proposal, Building Services Agreement. All services provided under this agreement will be performed during normal working hours (Monday Friday 7 a.m. 5 p.m.) unless otherwise specified. 6.0 TIMELINE FOR THIS RFP The Court has developed the following list of key events related to this RFP. All dates are subject to change at the discretion of the Court. EVENT DATE RFP issued January 24, 2014 Optional Walk Through Deadline for questions questions to: [email protected] February 6, :00 A.M. (Pacific Time) February 10, 2014 Close of Business Questions and Answers posted February 18, 2014 Latest date and time proposal may be submitted February 24, :00 P.M. (Pacific Time) Evaluation of proposals (estimate only) Week of February 24, 2014 Notice of Intent to Award (estimate only) Week of March 3, 2014 Negotiations and execution of contract (estimate only) Week of March 10, 2014 Contract start date (estimate only) April 1, 2014 Contract end date (estimate only) March 31, 2015 Page 8 of 13
9 7.0 RFP ATTACHMENTS The following attachments are included as part of this RFP: ATTACMENT Attachment 1: Administrative Rules Governing RFPs (Non-IT Services) Attachment 2: Court Standard Terms and Conditions Attachment 3: Proposer s Acceptance of Terms and Conditions Attachment 4: General Certifications Form Attachment 5: Darfur Contracting Act Certification Attachment 6: Payee Data Record Form DESCRIPTION These rules govern this solicitation. If selected, the person or entity submitting a proposal (the Proposer ) must sign this Court Standard Form agreement containing these terms and conditions (the Terms and Conditions ). On this form, the Proposer must indicate acceptance of the Terms and Conditions or identify exceptions to the Terms and Conditions. The Proposer must complete the General Certifications Form and submit the completed form with its proposal. Proposer must complete the Darfur Contracting Act Certification and submit the completed certification with its proposal. This form contains information the Court requires in order to process payments and must be submitted with the proposal. 8.0 SUBMISSIONS OF PROPOSALS 8.1 Proposals should provide straightforward, concise information that satisfies the requirements of the Proposal Contents section below. Expensive bindings, color displays, and the like are not necessary or desired. Emphasis should be placed on conformity to the RFP s instructions and requirements, and completeness and clarity of content. 8.2 The Proposer must submit its proposal in two parts, the Technical Proposal and the Cost Proposal. 1. The Proposer must submit one (1) original and three (3) copies of the Technical Proposal. The original must be signed by an authorized representative of the Proposer. The Proposer must write the RFP title and number on the outside of the sealed envelope. 2. The Proposer must submit one (1) original and three (3) copies of the Cost Proposal. The original must be signed by an authorized representative of the Proposer. The original cost proposal and the copy must be submitted to the Court in a single sealed envelope, separate from the technical proposal. The Proposer must write the RFP title and number on the outside of the sealed envelope. Page 9 of 13
10 8.3 Proposals must be delivered by the date and time listed on the coversheet of this RFP to: Paula D. Garcia Assistant Clerk/Administrator Court of Appeal, 4th Appellate District, Division th Street Riverside, CA Late proposals will not be accepted. 8.5 Only written proposals will be accepted. Proposals must be sent by registered or certified mail, courier service (e.g., FedEx), or delivered by hand. Proposals may not be transmitted by fax or PROPOSAL CONTENTS 9.1 Technical Proposal. The following information must be included in the technical proposal. A proposal lacking any of the following information may be deemed non-responsive. 1. Proposer s name, address, telephone and fax numbers, and federal tax identification number. Note that if Proposer is a sole proprietor using his or her social security number, the social security number will be required before finalizing a contract. 2. Name, title, address, telephone number, and address of the individual who will act as Proposer s designated representative for purposes of this RFP. 3. Acceptance of the Terms and Conditions. i. On Attachment 3, the Proposer must check the appropriate box and sign the form. If the Proposer marks the second box, it must provide the required additional materials. An exception includes any addition, deletion, or other modification. ii. If exceptions are identified, the Proposer must also submit: a. a red-lined version of the Terms and Conditions that implements all proposed changes; and b. a written explanation or rationale for each exception and/or proposed change. 4. Certifications, Attachments, and Other Requirements. i. The Proposer must complete the General Certifications Form (Attachment 4) and submit the completed form with its proposal. Page 10 of 13
11 ii. iii. iv. The Proposer must complete the Darfur Contracting Act Certification (Attachment 5) and submit the completed certification with its proposal. If Contractor is a California corporation, limited liability company ( LLC ), limited partnership ( LP ), or limited liability partnership ( LLP ), proof that Contractor is in good standing in California. If Contractor is a foreign corporation, LLC, LP, or LLP, and Contractor conducts or will conduct (if awarded the contract) intrastate business in California, proof that Contractor is qualified to do business, and is in good standing in California. If Contractor is a foreign corporation, LLC, LP, or LLP, and Contractor does not (and will not if awarded the contract) conduct intrastate business in California, proof that Contractor is in good standing in its home jurisdiction. The Proposer must describe its capability in performing the inspection services and its experience in performing services of a similar nature. v. The Proposer must submit copies of its certifications for each individual that will perform inspections at the work location. vi. The Proposer must submit a sample inspection and preventive maintenance work plan for evaluation purposes. vii. The Proposer must submit its Standard Agreement for Inspection and Maintenance Services for evaluation purposes. 9.2 Cost Proposal. The following information must be included in the cost proposal. 1. A detailed line item budget showing total cost of the proposed services 2. A full explanation of all budget line items in a narrative entitled Budget Justification, including hourly rates. 3. A not to exceed total for all work and expenses payable under the contract, if awarded. 4. For each of the option years, provide either specific costs or a labor or cost index for any increase in the initial term s costs. NOTE: It is unlawful for any person engaged in business within this state to sell or use any article or product as a loss Leader as defined in Section of the Business and Professions Code OFFER PERIOD A Proposer's proposal is an irrevocable offer for ninety (90) days following the proposal due date. In the event a final contract has not been awarded within this period, the Court reserves the right to negotiate extensions to this period. Page 11 of 13
12 11.0 EVALUATION OF PROPOSALS At the time proposals are opened, each proposal will be checked for the presence or absence of the required proposal contents. The Court will evaluate the proposals on a 100 point scale using the criteria set forth in the table below. Award, if made, will be to the highest scored proposal. If a contract will be awarded, the Court will post an Intent to Award notice at CRITERIA MAXIMUM NUMBER OF POINTS Quality of work plan submitted 10 Experience 30 Reasonableness of cost projection 30 Credentials of staff to be assigned to the project 20 Acceptance of the Terms and Conditions 10 Total Number of Points INTERVIEWS The Court may conduct interviews with Proposers to clarify aspects set forth in their proposals or to assist in finalizing the ranking of top-ranked proposals. The interviews may be conducted in person or by phone. If conducted in person, interviews will likely be held at the Court s offices. The Court will not reimburse Proposers for any costs incurred in traveling to or from the interview location. The Court will notify eligible Proposers regarding interview arrangements CONFIDENTIAL OR PROPRIETARY INFORMATION PROPOSALS ARE SUBJECT TO DISCLOSURE PURSUANT TO APPLICABLE PROVISIONS OF THE CALIFORNIA PUBLIC CONTRACT CODE AND RULE OF THE CALIFORNIA RULES OF COURT. The Court will not disclose (i) social security numbers, or (ii) balance sheets or income statements submitted by a Proposer that is not a publicly-traded corporation. All other information in proposals will be disclosed in response to applicable public records requests. Such disclosure will be made regardless of whether the proposal (or portions thereof) is marked confidential, proprietary, or otherwise, and regardless of any statement in the proposal (a) purporting to limit the Court s right Page 12 of 13
13 to disclose information in the proposal, or (b) requiring the Court to inform or obtain the consent of the Proposer prior to the disclosure of the proposal (or portions thereof). Any proposal that is password protected, or contains portions that are password protected, may be rejected. Proposers are accordingly cautioned not to include confidential, proprietary, or privileged information in proposals DISABLED VETERAN BUSINESS ENTERPRISE PARTICIPATION GOALS The Court has waived the inclusion of DVBE participation in this solicitation PROTESTS Any protests will be handled in accordance with Chapter 7 of the Judicial Branch Contract Manual (see Failure of a Proposer to comply with the protest procedures set forth in that chapter will render a protest inadequate and non-responsive, and will result in rejection of the protest. The deadline for the Court to receive a solicitation specifications protest is the proposal due date. Protests should be sent to: Manuel A. Ramirez, Presiding Justice Court of Appeal, Fourth Appellate District, Division Twelfth Street END OF RFP Page 13 of 13
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
REQUEST FOR PROPOSALS
REQUEST FOR PROPOSALS SUPERIOR COURT OF CALIFORNIA COUNTY OF STANISLAUS REGARDING: RFP 15165003 PERIMETER AND LOBBY SECURITY PROPOSALS DUE: December 21, 2015 NO LATER THAN 4:00 P.M. PACIFIC TIME 1 rev
PLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
ADDENDUM NO. 1 TO THE BIDDING DOCUMENTS. HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport.
ADDENDUM NO. 1 TO THE BIDDING DOCUMENTS DATE: May 6, 2016 HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport BIDS CLOSE: May 12, 2016, at 2:30 p.m., Local Time TO ALL BIDDERS
Boiler and Burner Cleaning and Servicing Specifications
Boiler and Burner Cleaning and Servicing Specifications The Town of Groton of Public Works Department is requesting bids to provide manufacturers recommended maintenance, repairs and emergency service
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
Attachment J-C18.1. HVAC Work Instructions
. RFP: Attachment J-C18.1 HVAC Work Instructions NNC13ZFD017J SOW Item No. Title Page C18-02 Control Air Systems Annual PM 2 C18-03 Split System AC Indoor Section Annual PM 3 C18-04 Condensing Unit Semi-Annual
REQUEST FOR BIDS 2013-12 HVAC PREVENTATIVE MAINTENANCE AND SERVICE JANUARY 18, 2013. Issued by: NH Liquor Commission. PO Box 503, Concord, NH 03302
REQUEST FOR BIDS 2013-12 HVAC PREVENTATIVE MAINTENANCE AND SERVICE JANUARY 18, 2013 Issued by: NH Liquor Commission PO Box 503, Concord, NH 03302 This Page intentional left blank TABLE OF CONTENTS EXHIBITS...
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
HVAC Preventative Maintenance Basics. Presented by Mike Crawley
HVAC Preventative Maintenance Basics Presented by Mike Crawley Air Handlers/Package Units: Coils have to be clean! The main purpose of any coil is to absorb or reject heat If coils are dirty; air flow
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 08 02 PART 1 GENERAL 1.01 AUTHORITY (CxA) A. The Commissioning Authority (CxA) has been contracted or will be contracted directly
Request for Qualifications. For Heating, Ventilating and Air Conditioning Contractor Services
Request for Qualifications Request for Qualifications For Heating, Ventilating and Air Conditioning Contractor Services The Midcoast Regional Redevelopment Authority (MRRA) is a governmental agency created
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
COMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Action Plan Template HVAC Page 1
Action Plan Template HVAC Page 1 Once Establish expected HVAC system efficiency - Write down the expected efficiency of HVAC systems to use as a baseline - Add this information to maintenance plan documentation
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
Annual Service Agreement
Annual Service Agreement 462 Main Street P.O. Box 130 Royersford, PA 19468 610-948-7220 www.plottsenergy.com GAS OIL HEAT PUMP AIR CONDITIONING A family owned and operated business since 1949. We are here
DIABLO VALLEY COLLEGE CATALOG 2015-2016
HEATING, VENTILATION, AIR CONDITIONING, REFRIGERATION - HVACR Tish Young, Dean Physical Sciences and Engineering Division Physical Sciences Building, Room 263 Possible career opportunities Upon successful
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
REQUEST FOR QUOTATIONS
Metropolitan Washington Airports Authority Materials Management, MA-133 Terminal A, Room 278 Washington, DC 20001-4901 REQUEST FOR QUOTATIONS 1. FOR INFORMATION CONTACT NAME: Regina Leigh 2. REQUEST FOR
Preventive Maintenance. Learning Objectives: Howdy! Learning Objectives Cont:
Preventive Maintenance Fountain of Youth for HVAC Successful Learning Environment Bonus Strategies James D. McClure, P.E. Action Planning Guide As you listen to this presentation, use the chart in your
Mechanical Engineering Technician- Plant Technician
Mechanical Engineering Technician- Plant Technician A competent Mechanical Engineering Technician- Plant Maintenance is expected to: 1. Ability to plan and execute work in a safe and responsible manner
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
610-6-MURPHY 610-461-6502 PRIORITY SERVICE AGREEMENTS. 610-461-6502 PLUMBING HEATING COOLING DUCT CLEANING BATHS TILE Thank You. Richard G.
Contractor License PA#022799 PA#022799 PLUMBING, HEATING & AIR CONDITIONING 610-6-MURPHY OR 610-461-6502 PRIORITY SERVICE AGREEMENTS A staff of professionals waiting to serve you 24 hours a day 365 days
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
STATEMENT OF WORK FOR MAINTENANCE OF AIR CONDITIONERS
STATEMENT OF WORK FOR MAINTENANCE OF AIR CONDITIONERS 1) SCOPE: The successful bidder (Contractor) is responsible to perform periodic routine preventive maintenance and repair of all accepted air conditioner
Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services
Preventive Maintenance State Energy Assessment Workshop By: DTE Energy Partnership & Services Do you know? World wide research has shown that one of the reasons causing 80% of the accidents is deficient
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales SPECIFICATION FOR LAUNDRY EQUIPMENT MAINTENANCE Maintenance Module 32 March 2011 issue This document has been compiled by the Engineering
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Phone: (201) 290-7738 Phone: (212) 242-6525 Fax: (973) 272-2906
Phone: (201) 290-7738 Phone: (212) 242-6525 Fax: (973) 272-2906 Agreement for Preventive Maintenance Services and On Call Repair for Heating, Ventilation and Air Conditioning. *LABOR INCLUSIVE* Customers
Air Conditioning Maintenance Services
Town of Lauderdale-By-The-Sea REQUEST FOR PROPOSAL No. 14-05-01 Air Conditioning Maintenance Services RFP OPENING: July 29, 2014 2:00P.M. Town Hall 4501 Ocean Drive Lauderdale-By-The-Sea, FL 33308 acs
HVAC Checklist - Long Form
HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,
1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%
1 1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53% 2. How much money do commercial facilities spend per square foot on energy costs
SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK
SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK 1 GENERAL 1.1 GENERAL REQUIREMENTS A. This Section is coordinated with and complementary to the General Conditions and Supplementary General Conditions
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning
Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test
APTA STANDARDS DEVELOPMENT PROGRAM RECOMMENDED PRACTICE American Public Transportation Association 1666 K Street, NW, Washington, DC, 20006-1215 APTA BTS-BMT-RP-001-10 Approved October, 2010 APTA Bus Maintenance
Protect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement.
Protect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement. The benefits of a Home Service Agreement Provides peace of mind Regularly scheduled maintenance will keep
C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).
SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE
Contractor Services for the Direct Installation of Heat Pump Water Heater and Ductless Mini-Split Heat Pumps in Income-Eligible Vermont Households
Notice Type: Request for Proposal Short Title: Low Income Heat Pump Posted date: August 8, 2014 E-mail response date: August 29, 2014 Contact: [email protected] Contractor Services for the Direct
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
Plan Number. 1624- A Cross Beam Dr. Charlotte, NC 28217 704.771.1020. www.charlottemechanical.com. Simplified Service Plan. Air Conditioning.
Plan Number 1624- A Cross Beam Dr. Charlotte, NC 28217 704.771.1020 www.charlottemechanical.com Simplified Service Plan Air Conditioning And Heating System PARTS, LABOR, & EMERGENCY REPAIR Effective Date:
REFRIGERATION & AIR-CONDITIONING UNIT IIT KHARAGPUR
REFRIGERATION & AIR-CONDITIONING UNIT IIT KHARAGPUR Sub.: Day-to-Day operation contract & maintenance for 2 X 40 TR &1 X 20 TR DX type Central AC Plant of Netaji Auditorium of IIT Kharagpur Ref.: IIT/RAC/Netaji/OC
SMITH PLUMBING & HEATING 2012 Home Care SERVICE PLAN AGREEMENT. A. Silver Plan
SMITH PLUMBING & HEATING 2012 Home Care SERVICE PLAN A. Silver Plan AGREEMENT Priority Emergency Plumbing / Heating Repair Service: All service labor will be billed at our prevailing labor rate with no
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
Facilities Maintenance Standards rev 9-1-2015
Facilities Maintenance Standards rev 9-1-2015 Purpose The purpose of these standards is to outline the minimum requirements for maintaining state owned facilities and infrastructures in a manner that will
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
Energy Efficiency in Industrial HVAC Systems
Energy Efficiency in Industrial HVAC Systems Heating, ventilation and air conditioning (HVAC) constitutes up to 35 percent of energy used in manufacturing facilities. This fact sheet is geared towards
EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY
EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY Spectrum Manufacturing warrants that the heat pumps and air handling equipment (if purchased with a Water to Water System) manufactured by Spectrum Manufacturing
Sample Company SECTION 019113 GENERAL COMMISSIONING REQUIREMENTS PART 1 GENERAL 1.1 SUMMARY AND CONTRACT RESPONSIBILITIES
SECTION 019113 GENERAL COMMISSIONING REQUIREMENTS PART 1 GENERAL 1.1 SUMMARY AND CONTRACT RESPONSIBILITIES A. The Owner will contract separately and directly for the majority of the commissioning work
REQUEST FOR PROPOSAL FOR DORCHESTER COUNTY COUNCIL HVAC SERVICES DCG 12-02. Due Date December 6, 2011
REQUEST FOR PROPOSAL FOR DORCHESTER COUNTY COUNCIL HVAC SERVICES DCG 12-02 Due Date December 6, 2011 DORCHESTER COUNTY COUNCIL 501 COURT LANE, ROOM 110 CAMBRIDGE, MARYLAND 21613 I. INTRODUCTION Dorchester
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT) MAINTENANCE TYPE: STATUTORY 1.0 SCOPE OF SERVICES The Contractor shall provide maintenance Services for
B.C. Buildings Corporation. Mandatory Preventive Maintenance Standard. To Meet Section 4.78 of the WCB OH & S Regulation
B.C. Buildings Corporation Mandatory Preventive To Meet Section 4.78 of the WCB OH & S Regulation Prepared by: BCBC WCB-IAQ Steering Committee Mandatory Preventive TABLE OF CONTENTS Page no. INTRODUCTION...1
USF St. Petersburg Operations & Maintenance of Facilities Preventative Maintenance Guide
USF St. Petersburg Operations & Maintenance of Facilities Preventative Maintenance Guide GUIDE EQUIPMENT TYPE & TASKS FREQUENCY A-1 Air Dryer 1. Lubricate valves and replace packing, if necessary 2. Check
HVAC Claims: Repair vs. Replacement
HVAC Claims: Repair vs. Replacement Curtis M. VanNess Field Operations Manager Outline Brief history of HVAC How do HVAC systems work? Types of systems and equipment Causes of failure Repair vs. Replace
Basics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
First irst Co. Products
First irst Co. Products Recommended Maintenance Program PM1193 FIRST OPERATIONS,LP - P.O. Box 270969 - Dallas, Texas 75227 - www.firstco.com Table of Contents Introduction... 3 General Precautions... 3
Backup Fuel Oil System Decommissioning & Restoration Plan
Backup Fuel Oil System Page 1 of 19 Overview of Physical Fuel Oil System and Decommissioning Steps The fuel oil system at Milford Power consists of a number of subsystems. These include the following:
DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD
DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD JOB DESCRIPTION POSITION TITLE: Air Conditioning Mechanic DEPARTMENT: Plant TITLE OF IMMEDIATE SUPERVISOR: Supervisor, Maintenance Services Position Summary
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Building Commissioning 17900-1
SECTION 17900 BUILDING COMMISSIONING PART 1 - GENERAL 1.01 WORK DESCRIPTION: A. General: 1. The Commissioning process is a joint team effort to ensure that all mechanical equipment, controls, and systems
PACKAGED FIRE TUBE BOILER
SAMPLE PREVENTIVE MAINTENANCE MANUAL PACKAGED FIRE TUBE BOILER 1 CONTENTS Introduction 1 Intention 2 Organisational setup 3 Boiler Fault reporting & Repair progression 4 Preventive Maintenance Schedules
Commissioning - Construction Documents (Page 1 of 6)
Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem
BVCAA inc. 2015 HVAC Service Bid Sheet Item Description. Materials Labor Total 3/24/2015
BVCAA inc. 2015 HVAC Service Bid Sheet Item Description Materials Labor Total 3/24/2015 A. Manual J and Manual S Required NC NC YES Duct Blaster Reading Required NC NC YES HVAC Furnance CO Reading Required
10 YEAR WARRANTY REGISTRATION PROCEDURES. Please see product warranty section in back of book for registration procedures
10 YEAR WARRANTY REGISTRATION PROCEDURES Please see product warranty section in back of book for registration procedures Carrier Systems are eligible for 10 YEAR Warranty Coverage when registered! Important
HVAC Applications. VFD considerations for HVAC systems...
HVAC Applications VFD considerations for HVAC systems... 1 COMMON TERMINOLOGY VFD (VARIABLE FREQUENCY DRIVES) AFC (ADJUSTABLE FREQ. CONTOLLER) ASD (ADJUSTABLE SPEED DRIVES) VSD (VARIABLE SPEED DRIVES)
INSTRUCTIONS TO BIDDERS
INSTRUCTIONS TO BIDDERS ALL CONTRACTORS SUBMITTING A RESPONSE TO THIS INVITATION TO BID MUST HAVE COMPLETED THE FORMS CONTAINED IN THIS INVITATION TO BID. FORMS SUBMITTED WHICH ARE NOT IN THE FORMAT OF
How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.
Demystifying HVAC Test Your HVAC Knowledge By Ron Prager How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page. 1)
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility
COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC)
COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC) REBATE FORM Valid July 1 - December 31, 2015 Steps to Getting Your Rebate: 1. Confirm that equipment is eligible. 2. Purchase and install new eligible
Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE <[email protected]
Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE
Statement of Work. 3.0 Details of Service Pre Start-up. - 1 - Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary
Installation Service Statement of Work - 1 - Cooling Start-up Service Cooling Start-up Service Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details
D Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00
SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air
Guide Specification SECTION 23 08 00 - COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY
SECTION 23 08 00 - COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. HVAC Commissioning description. 2. HVAC Commissioning responsibilities. 1.2 REFERENCES A. American Society
Fossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
HVAC Repair and Maintenance Strategies by Ron Prager
HVAC Repair and Maintenance Strategies by Ron Prager (Demystifying HVAC) The PRSM editorial board recently raised the question of the best, strategic approach to HVAC maintenance. Of course, there is no
Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)
UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system
The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers
The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers Table of Contents Introduction... 1 Intention... 2 Authority and responsibility letter... 3 Organizational
Air Conditioning Systems Warranty Manual. Version 1.8
Air Conditioning Systems Warranty Manual Version 1.8 1/2015 Air Conditioning System Warranty Contents Purpose 4 External Distribution... 4 Policies 5 Warranty Policy Overview... 5 Warranty Period... 5
REMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
Judicial Council of California
Judicial Council of California Finance Division 455 Golden Gate Avenue San Francisco, CA 94102-3660 Telephone 415 865 7960 Fax 415 865 4325 TDD 415 865 4272 RONALD M. GEORGE Chief Justice of California
48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT
48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and