System 9000 Alarm Annunciator
|
|
|
- Ashley Sherman
- 10 years ago
- Views:
Transcription
1 System 9000 Alarm Annunciar Ultimate flexibility and reliability in a rack-mounted format Exclusive ASIC/micro-controller technology Multi-redundant design (no single point of failure) including PSU and communications Modular, rack-mounted design expandable thousands of alarm points Fully field programmable using the integral Setup Card or RTK configuration software Alarm sequences ISA-S (R 1984) Wide range of displays including mimic diagrams, LED light boxes The System 9000 Alarm Annunciar offers the latest in combined ASIC/micro-controller technology provide an annunciar of unparalleled reliability and programmability. The system gives flexibility and security at a cost-effective price. A unique multi-redundant design is used in the System 9000 which avoids the need for a central controller and also provides multi-redundant PSU and communications. The programming flexibility means that users can easily configure hundreds of options including alarm sequence, time delays, relay operation, first-up grouping, functionality, communications etc. The range of displays complement the System 9000 is also extensive, from the ultra-bright LED illuminated P725LO, hazardous area displays and alarm management software screens.
2 Features & Benefits Provides independent annunciation of critical plant alarms whilst communicating back the host DCS, PLC, ESD, SCADA or computer system Fully field programmable, from integral Setup Card or your configuration software Suitable for systems from a basic eight-way annunciar a plant-wide alarm management system Total flexibility in choice of system size, display style, operation and options Field proven technology, with hundreds of thousands of alarm points already in operation worldwide Options available for multiplexing, sequence of events recording, etc. With the continued improvements in the complexity of process plants combined with the pressures strive for greater operating efficiency, it is even more important that alarm annunciars offer the clearest means of showing alarms combined with the best reliability and highest integrity. RTK has designed the System 9000 rack mounted alarm system with this in mind. Based on the field proven and highly acclaimed range of panel mounted Annunciars, the system employs exclusive ASIC and microcontroller technology with additional safety, communications and configuration facilities. Total Configurability All the facilities are field programmable using the in-built keypad or downloaded from a pc using RTK s Setup Software. All features are configurable for each individual alarm way and can easily be set up in minutes without the need learn a special programming language. All the alarm sequences specified in the ISA publication Annunciar Sequences and Specifications are available in addition a wide range of additional features. Displays The System 9000 is suitable drive almost any display, such as complex mimic diagrams, simple LEDs, or backlit lamp displays of a vast range of shapes and sizes. RTK Instruments can offer a whole range of display options for the System 9000, which are fully detailed in a separate datasheet. Total Flexibility The modular construction and the advanced programming facilities mean that the System 9000 Alarm Annunciar can be supplied match any process alarm application. The 19in racking system allows almost unlimited system expansion, and the Setup Card allows configuration down each individual alarm way for both sequence and operation. High Density Packaging A standard rear mounting 19in 3U Eurorack forms the basis of the System Each rack can contain up 14 eight channel active input cards giving a tal of 109 alarm ways and three pushbutns per rack. Racks can easily be linked gether produce alarm systems of almost unlimited size. First Up In alarm annunciation applications, it is often essential know which alarm occurred first. For this reason, the System 9000 has a flexible high resolution first-up facility as standard. Four different first-up sequences are provided match the ISA standard S (R 1984). Up four separate first-up groups can be defined within the one system; each alarm way can be configured as being in one of these four groups. Relay Outputs The standard system has relay outputs for all the commonly used functions, such as a horn relay, watchdog relay and tal group relay (with optional reflash). If additional relays are required, then the optional Group Relay Card may be needed. This card will expand the relay outputs from the system by an additional eight. Each alarm way can also be supplied with individual user configurable repeat relay outputs. Active input card Communications The communications facility allows the System 9000 act as a data acquisition system and transmit alarm information serially SCADA systems, computers, plcs, DCS systems etc. With the unique multi-redundant design, all cards can communicate directly the host system so there is no risk of card failure causing the communications halt. This method of data transmission will operate over 1.2km and uses standard MODBUS procol. Isolated Inputs Inputs are generally ly open or ly closed volt-free contacts. All inputs are op-isolated as standard and can accept 24VDC signals without alterations. There are options for the higher field contact voltages of 48, 110 and 250VDC. Bulb Fault Indication If any alarm way is unable light its window, because either both lamps are open circuit or missing, or one of the lamps has failed short circuit, then a green status LED on the input card flashes indicate this problem. The lamp test pushbutn can then be pressed find the faulty window. None of the above malfunctions will prevent the alarm annunciar from detecting and sounding alarms. Servicing All alarm ways are configured from the keypad on the Setup Card mounted on the left hand side of the rack, or on systems with communications, this can be downloaded from the Setup Software. In the unlikely event of a card failure, the cable connections can be unplugged from the card and the card itself unplugged from the rack. This allows very fast card replacement without the need for any rewiring.
3 Features & Benefits Setup Card Each system is supplied with a Setup Card. This card is not a master module; it is not required for the system run correctly. The function of the Setup Card is allow users configure the input cards their required operation. Once configured, all settings are sred on the EEPROM on the Active Input Cards. The Setup Card also filters and protects the incoming power supply and provides the common relay outputs. Alarm Management Software With its multi-redundant architecture and communications facility the System 9000 is an ideal front-end a screen based alarm management system. RTK can provide alarm management software and complete systems using industrialised computers and screens. These are developed in conjunction with the users provide the clearest possible means of showing alarms, the priority of these alarms and exactly what do in each alarm situation. These systems can also provide a means of logging all alarm and event hisry for analysis at a later date. Mounting The standard method of mounting is directly on the backplate of a control panel. The rack can easily be supplied as a front mounting 19in subrack suitable for direct mounting in 19in racking systems. Power Supply The supply voltage range for the system is wide enough for unregulated and battery backed supplies. The nominal 24VDC supply can be anywhere within the range 19-36VDC without affecting system performance. Alternative supply systems such as 48VDC can also be provided. Interfacing The System 9000 is ideally suited interface other plant equipment. Even basic systems come complete with output relays link external indicating devices and displays. The relays can be expanded cover multiple group relays and individual repeat relays for all alarm ways. Using the powerful communications features it is possible interface Setup card existing PLCs, SCADA systems, Emergency Shutdown Systems and plant-wide distributed control systems. The Annunciar can monir and display critical alarms and communicate the results in the moniring systems, giving another level of safety and independence from the general moniring or control system. Pushbutn Inputs The standard requirement for the majority of alarm annunciars is three pushbutns for Lamp Test, Accept and Reset. The System 9000 not only allows these standard functions, but can also allocate a further five inputs operate additional more advanced control features. If these are not required, they are simply not used. The additional functions are Silence, System Test, First-up Reset, Sleep and Horn Inhibit. RTK Engineering s Total Security Concept Multi-redundant design The System 9000 maintains the unique multi-redundant design. Each alarm board contains an ASIC (Application Specific Integrated Circuit) which is capable of complete system control if one board fails, or is removed, then another ASIC on another board will takeover system control, avoiding a single source of system failure and vastly increasing the system MTBF. An in-built watchdog relay will give an alarm if any Active Input Cards fail or are removed. Multi-redundant Communications This principle is now extended the communications. All active alarm boards have full communications facilities if a single board fails, an alarm is sounded but communications will continue with all the remaining boards. Again, this removes the single source of communication failure and goes far beyond a dual redundancy system. Multi-redundant Power Supply Each alarm card has its own in-built fully isolated dc/dc converter, again providing distributed power supplies across the whole alarm system, so the system does not rely on a single power supply card. Line Moniring The integrity of the rack itself is without question, but what of the connections the outside world? Alarm contacts: The System 9000 can be supplied complete with an extensive line moniring facility. If the connections the alarm contact go either short circuit, open circuit or high resistance then an alarm is sounded identify the problem. Lamp Failure: The connection the lamp display module can also be fully monired, so that if any alarm way is unable light its lamps the system will also sound an alarm. Both features can have volt-free relay contact outputs.
4 Displays To complement the System 9000 Alarm Annunciar, RTK Instruments offers a wide range of displays from simple lamp arrays full mosaic mimic diagrams. Most of the displays are modular in design enable RTK match your exact needs, rather than compromising on the nearest available shape and size. The main display types are illustrated and described here; for more detailed information, refer the separate display datasheet. P725LO Lamp-Only Modules This display has been designed match the Series 725 Alarm Annunciar it will look identical when viewed from the front. It is available in exactly the same format as the annunciar with three window sizes, six colours and a choice of lamp or LED illumination. This display is the best choice when LED illumination is required, offering the most competitive ultra-bright illumination. It is fitted with a Lamp Test facility as standard. DF30 Display Facia The DF30 display facia provides a flexible display panel for both LED or incandescent lamps. This display facia is tally modular allowing systems of almost any shape and size be constructed. The basic lamp module is 30 x 30mm but these can be configured give a range of window shapes and sizes by interconnecting multiple windows. This display can also have integral pushbutns, keyswitches and audible devices. There is no limit the number or position of these devices. All connections are by rear mounted screw terminals. Hazardous Area Displays When supplied through suitable certified interface devices, the System 9000 can be used drive a display facia in the hazardous area. The DF30IS is a backlit display certified as Ex II 1G, EEx ia IIC T4. The display gives a bright LED illuminated backlit display that matches the safe area versions. The L20 Intrinsically Safe Multiplexer can also be used drive a hazardous area display using only two cables in the hazardous area. IP65 Displays Where protection from the environment is essential a range of displays sealed IP65 can be provided. These cusm-built units have bright LED display modules wired rear mounted terminals. The completed assembly is mounted with a gasket the panel door maintain the sealing. Mimic Displays Mosaic tiled mimic systems can be driven by the System 9000 provide a flexible and informative overview display. The standard mosaic mimic uses a 24 or 25mm tile mounted on a strong aluminium honeycomb grid. Tiles are the moulded type for process mimics or alternatively screen-printed or engraved form the required display drawing. A wide range of suitable lamps, switches, pushbutns and displays can also be integrated in the finished mimic. On smaller projects and simpler display requirements a hard wearing, single piece mimic can also be provided. Alarm Management Software With its multi-redundant architecture and communications facility the System 9000 is an ideal front-end a screen based Alarm Management System. These can be set up in thousands of different ways suit each individual alarm handling situation. Different display screens have already been developed and these building blocks would be used provide a cusm solution for each client. These systems could also incorporate uch screen displays, dual redundant servers and a range of industrial computers.
5 Advanced Features The Best of Both Worlds Ideally, critical plant alarms should be hard wired a dedicated alarm system like the System 9000 and data passed on the DCS as a secondary function. This offers the best of both worlds in that the System 9000, which has been specially developed offer high speed event capture and True First Out Discrimination, also provides the clearest possible indication of critical plant conditions. The System 9000 provides an independent, highly reliable, modular alarm system employing multiple redundant design features. It should be used complement centralised DCS platforms that have been primarily developed for control and moniring. Most of the features listed here are supplied as standard as part of the software; the system is simply configured exactly as required for each application. Further options exist from RTK provide complete systems, undertake programming and commissioning, and provide alternative mounting arrangements. Please consult the Sales Office for further information on any of these options. Timers Delay timers can be incorporated in the System 9000 on both the inputs and the outputs. This facility can avoid the possibility of nuisance alarms by setting an input time delay, so that the alarm contact must be in alarm for a certain time before triggering the input circuitry. Repeat Relays Each alarm way can have an individual repeat relay output in addition any group relays configured. The relays can be set up as energised or de-energised on alarm and N/O or N/C contact. The relay functions are also user configurable follow the alarm logic or follow the input. Group Relay Card An additional card is available for those systems requiring more than the standard 3 relay outputs. The card has 7 additional group relays and an further 3 horn relays, all of which are fully configurable. Any alarm way in a system can be configured in any of the 8 possible groups or 4 possible audible groups. Three of these group relays can alternatively be configured give outputs for line fault, communications fault and bulb failure. Output Relay Reflash Each of the group relays can have the reflash facility enabled. This is where the group relay will change state for approx 0.5s when another alarm in that group occurs. This allows a control room annunciar or moniring system indicate each occurence of a new alarm. Alarm Indication via PLCs The cost of digital output cards for PLCs drive conventional backlit displays can be avoided by simply communicating all the alarm information serially a System 9000 annunciar. The Annunciar will then convert the serial information and drive the lampbox display. Multiple Input Reflash It is often necessary connect more than one alarm contact a single alarm display window. This can be configured from the Setup Card so that up 24 alarm contacts can all link a single alarm window. After an alarm has occurred and been accepted then another alarm occurring in the same group will cause the display window flash again (reflash) indicate the occurrence of a new alarm. Discrepancy Rather than simply moniring the state of a single alarm contact, it is possible configure the Annunciar monir two or more contacts ensure they correspond. If the two contacts go out of sync, a fault has occurred and the alarm will sound. Boolean Logic In a similar way the discrepancy control, multiple inputs can be linked gether by standard OR and AND functions. For example, the system can be programmed so that an alarm will only occur if four particular inputs are all on at the same time. Sleep Mode Useful in unmanned/not ly manned situations. Any single input can be configured as a sleep input. When this input is switched on the drive outputs the lamps and audibles are disabled. The annunciar will work exactly the same in all other respects; all alarms are monired as standard and all repeat relays and communications function as. As soon as the system is switched out of the sleep mode, the display facias will display all alarm information, complete with all first-up details. Multiplexer To cut down on the costs of installing vast numbers of cables across large sites, the System 9000 can be used as an economical multiplexer system, where all the alarm contacts are gathered by a single System 9000TX Module and transmitted serially on 4 wires up 1.2 km away the receiving module, the System 9000RX Module. The alarms can then be displayed on a display facia or via VDU screens. Complete Systems RTK can provide the System 9000 mounted in a wall mounted or floor standing cabinet and provide all the necessary wiring the displays, PSUs and terminals ready for final installation on site. These panels are quoted against each specific cusmer requirement; please contact the Sales Office for further details. Card Types Active Input Card (P925A) Connects the alarm and pushbutn inputs and drives the lamp facia display. Setup Card (P925S) Allows configuration of Active Input Cards, filters the incoming supply voltage and provides 3 relay outputs. Relay Card (P925R) This card is connected directly the Active Input Card and gives an individual repeat relay per alarm input. Group Relay Card (P925G) Has 8 relays fitted, 7 additional group relays and 3 additional horn relays. Interface Card (P925X) Provides a link the systems communications facilities via RS485. Power Input Card (P925P) Used on extension racks in place of the setup card. This simply filters the incoming power and provides a connection the rear backplane. Interconnect Card (P925I) Use on larger systems buffer the signals between racks and link the common lines. Supplied with an interconnect cable.
6 Sequence tables Each alarm channel can be configured suit the operating sequence required as listed in the ISA publication Annunciar Sequences and Specifications S (R1985). Systems can be configured with different features on different alarm ways and there is no need switch the power off. The diagram below shows the most commonly used sequences. MANUAL RESET reset AUTOMATIC RESET return PROCESS Ab NO LOCK IN return Sequence Code M SEQUENCE Alarm Sequence Code A SEQUENCE Alarm return SEQUENCE Alarm AUTOMATIC RESET FIRST OUT WITH FIRST OUT FLASHING AND RESET PUSHBUTTON first out reset return PROCESS Ab SEQUENCE Subsequent Acknowledged subsequent SEQUENCE Subsequent Alarm VISUAL Fast Flashing first out reset SEQUENCE First Acknowledged subsequent SEQUENCE Subsequent Alarm Sequence F3A first out reset first SEQUENCE First Alarm VISUAL Intermittent Flashing MANUAL RESET FIRST OUT Sequence F2M-1 WITH NO SUBSEQUENT ALARM FLASHING AND SILENCE PUSHBUTTON reset mute and (first out reset) first SEQUENCE First Alarm RINGBACK reset SEQUENCE Ringback VISUAL Slow Flashing ALARM RINGBACK return ALARM RINGBACK acknowledg e return PROCESS Ab ALARM RINGBACK Sequence Code R SEQUENCE Alarm VISUAL Fast Flashing ALARM RINGBACK (first out reset) PROCESS Ab SEQUENCE First Silenced AUTOMATIC RESET FIRST OUT WITH NO SUBSEQUENT ALARM STATE return subsequent (first out reset) mute Sequence F1A first SEQUENCE First Alarm AUDIBLE (first out reset) Audible
7 Installation and Mechanical Details Standard system with Communications Local Annunciation DCS/ESD Printer Alarm Management Software PLC PLC Alarm inputs (up 109/rack) and control inputs (T, A, R) System 9000 Multiplexed system Alarm inputs (up 109/rack) and control inputs (T, A, R) System 9000TX System 9000RX up 1.2km Five module, half 19in rack The System 9000 is based on the standard eurorack, manufactured IEC (DIN 1494 Pt.5). The standard subrack size is 3U and 84E wide (19in). This module will fit the Setup Card and up 14 Active Input Cards. For smaller systems, a half rack version is available, this is 42E wide (101 2in) and will fit the Setup Card and up 5 Active Input Cards. The units can be supplied as rear mounting for direct fixing backplanes or front mounting for use in 19in racks. Larger systems can be supplied by interconnecting multiple racks. All signals are fully buffered using the Interconnect Card, so no signal deterioration will occur even on extremely large systems. Fourteen module, full 19in rack (19in)
8 Technical Specification Inputs Alarm Contacts All inputs are op-isolated (isolation voltage 500VDC). By using different wiring configurations, the same system can be used for both: Volt-free contacts which can have the operating mode configured using the Setup Card, operate alarm for contact open or alarm for contact closed. Voltage input from 19VDC minimum 36VDC maximum with a common 0V for the 24VDC system and 38 58VDC for the 48VDC system. 110V field contact voltage option Alarm Contact and Cable Resistance N/C contact series resistance of contact cables 20kΩ maximum. N/O contact parallel resistance of contact cables 200kΩ minimum. Field Contact Voltage and Current The voltage for volt-free alarm contacts is fed from the unit at 24VDC at approximately 2mA. To maintain complete isolation it is possible use a separate PSU feed all the alarm contacts. Input Transient Filter (24V input) Signals narrower than approx 40ms at 30V will not trigger the annunciar. Tolerable transient at higher voltages: 100V for 2ms 200V for 1ms 1kV for 200µs First-up Discrimination Typical 10ms Control Inputs Any input can be configured one of the following control inputs: Lamp test Mute Acknowledge First-up reset Reset Sleep System test Horn Inhibit Outputs Lamp Drive Each output can drive up 160mA at 24VDC, making it suitable for multi bulb displays or multiple repeat displays. Standard Relays Standard relays fitted on the Setup Card: Horn, Group and Watchdog. Contact rating 3A at 24VDC resistive or 2A at 240VAC resistive. Selection of N/O or N/C contact by jumper link. Repeat and Group Relays Group relay card and individual repeat relays for each alarm way. Contact rating 3A at 24VDC resistive or 2A at 240VAC resistive. Relay ouputs may be ly energised or ly de-energised and contacts can be N/O or N/C. Communications Alarm data can be transmitted using the serial communications port other System 9000 units, DCS systems, PLCs or computers. Transmission RS485C. Full duplex, 1 start bit, 7 data bits, 1 parity, 1 sp bit. Baud Rate up 9600 Procol ASCII MODBUS and RTU General Supply Voltage 24VDC nominal (19 36VDC) Standard 48VDC nominal ( 38 58VDC) A range of power supplies is available convert from other ac or dc voltages. Supply current (ma) 24V 48V Quiescent: Setup Card Quiescent: Active Input Card Relay current/per relay Add the current for the lamp drive the tals of the above cards EMC Compliance Immunity EN :2001 Emissions EN :2001 LVD Compliance The unit is designed and manufactured safety specification BS EN :1993 Environment Operating temperature 20 C +60 C Srage temperature 20 C +80 C Humidity 0 95% RH, non-condensing Protection IP41 Mechanical Details 19in Rack Standard 3U by 19in Eurorack IEC (DIN 1494 Pt.5) for up 109 alarm inputs and 3 control inputs. Standard 3U by in Eurorack IEC (DIN 1494 Pt.5) for up 37 alarm inputs and 3 control inputs. Larger systems can be provided using multiple racks and interconnect cable. Mounting Either rear mounting direct backplate or front mounting in a standard 19in racking system. Assembly All cards plug in a standard pretested motherboard using DIN41612 connecrs. This allows simple system expansion of system size at a later date. Connections Two part rising clamp terminals, maximum cable size 2.5mm 2. Side mounted and front mounted screw terminals are available. Due our policy of continuous product development, we reserve the right amend specifications without notice. FM14290 ISO9001:2000 5YEAR GUARANTEE RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ Telephone: +44 (0) Facsimile: +44 (0) Web: [email protected] Doc S9000-0
AIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
TX2123 RS485 TO ETHERNET ADAPTOR
TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
M1000 Process Alarm Monitor
Data Sheet Process Alarm Monitor Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
COMPALARM AP GENERAL MAIN FEATURES
GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
MTL process alarm equipment. Flexible, reliable monitoring and notification for critical process alarms
MTL process alarm equipment Flexible, reliable monitoring and notification for critical process alarms Contents RTK alarm annunciators 4-5 RTK hazardous area alarm annunciators 6-7 RTK events recorders
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
VEGA Analogue Addressable Control Panels
Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
MSL1000 Monitored Serial Link Interface Manual V1.01
Audix Systems, Station Road, Wenden, Saffron Walden, Essex, CB11 4LG. Telephone: +44(0)1799 540888 Facsimile: +44(0)1799 541618 www.tycosafetyproducts-europe.com www.audixsystems.co.uk MSL1000 Monitored
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS
PROCESS AUTOMATI FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIS Pepperl+Fuchs Elcon The Leader In Intrinsic Safety And HART Interface Solutions The HART interface solutions (HIS) family of products from
Series Six Plus Programmable Controller
Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
VIBROCONTROL 4000. Sensitive Machine Monitoring
VIBROCONTROL 4000 Sensitive Machine Monitoring Reliable Machine Protection with VIBROCONTROL 4000 Brüel & Kjaer Vibro has for many years been one of the leading manufacturers of machine protection systems.
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
Auto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs
AlarmSense 2-wire detection and alarm system. Product Guide
AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description
SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Shadow TX(A) Shadow RX
Shadow TX(A) Shadow RX Asset Management and RFID Transmitter Tags Asset Management Receiver The Shadow TX(A) and Shadow RX wireless asset management system is a standalone wireless asset tracking system
650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description
INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
PowerGem Pro Uninterruptible Power Supply
Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
Installation manual. Version 1.1. www.videx-security.com
Installation manual Version 1.1 www.videx-security.com 2 Table of Contents MANUAL INTRODUCTION... 4 SYSTEM INTRODUCTION... 4 SYSTEM COMPONENTS... 5 CONTROLS... 6 3.5A 13.8Vdc PSU... 6 CONTROL PCB... 6
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C
F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
725 Series Alarm Annunciator Instruction Manual
725 Series Alarm Annunciator Instruction Manual 1 The following methods are used in this manual to alert the user to important information:- WARNING! Warnings are provided for safety and MUST be followed
Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction
Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are
Programmable Logic Controller PLC
Programmable Logic Controller PLC UPCO ICAI Departamento de Electrónica y Automática 1 PLC Definition PLC is a user friendly, microprocessor based, specialized computer that carries out control functions
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
T a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
INSTALLATION MANUAL PC2525. Version 1.1
INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).
Page 1 of 30 Page 2 of 30 1. Basic terminology - Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF). - Remote Element:
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
conventional system operation
conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Expandable with a safe bus system Reduction of expenditures
AC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
DCM. Product Brochure. Diagnostic Communication Master
DCM Product Brochure Diagnostic Communication Master DCM The DCM Diagnostic Communication Master is the best solution for the control of actuators from a remote control room through a two-wire transmission-mode
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL. 1.01 Summary. A. Section Includes:
SECTION 13421 PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL 1.01 Summary A. Section Includes: 1. The ISS shall furnish all labor, materials, equipment, services and incidentals
Bristol ControlWave Redundant Control
October 19, 2007 - Page 1 Bristol ControlWave Redundant Control Redundant systems are offered for critical processes and harsh applications that require maximum operational readiness and system availability.
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
PROXIMITY CARD READERS C-10, C-20, C60, C70
Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection
ALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL
Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL User s Guide Version 1.0 07/01/2009 Michael Stevens & Partners Ltd. has made
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2