ASCO SERIES 300 Power Transfer Switches. Business-Critical Continuity

Size: px
Start display at page:

Download "ASCO SERIES 300 Power Transfer Switches. Business-Critical Continuity"

Transcription

1 SO SRIS 00 Power Transfer Switches usiness-ritical ontinuity

2 SRIS 00 Power Transfer Switches for Power Outage Protection. Where would you be without a constant flow of electrical power? We often take for granted that power will always be around when we need it. In reality, power failures are very common. nd when the power goes out, your business suffers. Power failures are unpredictable. They can occur at any time and for any number of reasons a bolt of lightning, a power surge, a blackout, an accident or even equipment failure. They come without warning and often at the most inconvenient times. It s for this reason that many businesses and other entities have invested in emergency power backup systems. Typically, the system consists of an engine generator and an automatic transfer switch (TS) which transfers the load from the utility to the generator. n TS with built-in control logic monitors your normal power supply and senses any interruptions. When the utility power fails, the TS automatically starts the engine and transfers the load after the generator has reached proper voltage and frequency. This happens in a matter of seconds after the power failure occurs. When the utility power has been restored, the TS will automatically switch the load back, and after a time delay, it will shut down the engine. With an utomatic Transfer Switch, you are protected 4 hours a day, seven days a week.

3 Typical pplications Telecom In the telecommunications industry, providing a high level of service and dependability is crucial. Lost power means an interruption in service for your customers and lost business for your company. For instance, with cell sites scattered across a wide geographical region and in many remote areas, the chances of an interruption in power are increased, making utomatic Transfer Switches a valuable resource at each location. To maintain dependable service, each cell site must be monitored 4 hours a day. This can be very difficult without some type of remote monitoring and testing capability. The SRIS 00 Transfer Switch, combined with SO s monitoring and control management system, is a costeffective, packaged solution which can help meet both of these challenging objectives without a major investment at each cell site. With SO s connectivity solutions you can remotely monitor and control numerous sites from around the corner or around the world. griculture Maintaining electrical power is vital to an agriculture operation. If the flow of power is interrupted, your operation could be at risk unless the backup generator is quickly activated. prolonged power outage can affect numerous aspects of the operation, from housing and feeding livestock to processing and producing the end product. With an SO SRIS 00 Transfer Switch, power will automatically be transferred over to your backup generator, eliminating the need to manually switch from utility to generator. When power is restored, the SO SRIS 00 Transfer Switch will, after an adjustable time delay to allow for utility stabilization, automatically switch the load back to the utility service. ommercial / Retail, Light Industrial The retail industry is very competitive. n electrical power failure can have a dramatic impact on a retailer s bottom line. If power is interrupted during peak shopping times, the effect could be extremely damaging to present and future business. power interruption will not only suspend shopping, it can also create safety problems, result in lost transaction data, lost account information and damage to data collection equipment. In addition, retailers who rely on controlled climates to protect valuable inventory could suffer even greater losses, especially if the power failure occurs at a time when no one is available to rectify the situation. To avoid any of these power outage problems, simply install a backup generator with an SO SRIS 00 Transfer Switch and power outage concerns will be a thing of the past. Municipal The SO SRIS 00 Transfer Switch can be a critical component of a municipal government s emergency power backup system. Residents of townships, cities and counties rely on police, fire, ambulance/first aid and other critical public sector services. n interruption in power would affect the ability of emergency services to effectively respond to the needs of the community. When time is a critical factor, such as when responding to a fire alarm or an emergency call, an SO SRIS 00 Transfer Switch can be a lifesaver, switching power to the backup generator. While not all municipal services are a matter of life and death, they are always expected to be there.

4 SRIS 00 Power Transfer Switches 4 Maximum Reliability & xcellent Value With a SRIS 00 Transfer Switch, you get a product backed by SO Power Technologies, the industry leader responsible for virtually every major technological advance in the Transfer Switch industry. The SO SRIS 00 was designed for one purpose to automatically transfer critical loads in the event of a power outage. ach and every standard component was designed by SO engineers for this purpose. The rugged construction and proven performance of the SO SRIS 00 assure the user of many years of complete reliability. The SRIS 00 is even designed to handle the extraordinary demands placed on the switch when starting or restarting stalled motors and switching high inrush loads. SO s SRIS 00 modular, compact design makes it easy to install, inspect and maintain. ll parts are accessible from the front so switch contacts can be easily inspected. Features The SRIS 00 is listed to UL 1008 standard for Transfer Switch quipment and S standard. for automatic transfer switches. Meets FP 110 for mergency and Standby Power Systems and the ational lectrical ode () rticles 700, 701 and through 000 amps in a compact design. vailable to 600 V, single or three phase. True double-throw operation: The single solenoid design is inherently inter locked and prevents contacts from stopping between sources or from being in contact with both sources at the same time. UL Listed Withstand & lose-on Ratings Switch Ratings amps vailable Symmetrical mperes RMS When Used With urrent Limiting Fuses Maximum Voltage When Used With Specific ircuit reakers 0 100, v/60Hz 10, , v/60Hz, , v/60Hz 4,000 60, , v/60Hz 4, , v/60Hz 4, , v/60Hz 50, ,000 40v/60Hz 65, ,1000,100 00, v/60Hz 65, , , v/60Hz 85, , , v/60Hz 100,000 otes: 1. urrent limiting fuse should be lass J type through 400 amps: use lass L type above amp fuse rating. Refer to publication 118 for specific manufacturer s breakers Fig. 1: SO Power Transfer Switch rated 00 amperes shown in Type R enclosure There s no danger of the SRIS 00 TS transferring loads to a dead source because the unique SO single-solenoid operator derives power to operate from the source to which the load is being transferred. asy-to-read flush-mounted control and display panel provides LD indicators for switch position and source availability. It also includes test and time-delay bypass switches as standard features. Standard engine exerciser for weekly automatic testing of engine generator set with or without load. djustable time-delay feature prevents switch from being activated due to momentary utility power outages and generator dips. Supplied with solid neutral termination. Optional switched neutral pole available. ccessory kits available. vailable for immediate delivery. ow available for service entrance applications. ontact SO for assistance.

5 SRIS 00 Power Transfer Switches Designed to Fit nywhere The SO SRIS 00 product line represents the most compact design of automatic power transfer switches in the industry. With space in electrical closets being at a premium, the use of wall or floor-mounted SO Power Transfer Switches assures designers optimum utilization of space. ll transfer switches through 000 amps are designed to be completely front accessible. This permits the enclosures to be installed flush to the wall and still allows installation of all power cabling and connections from the front of the switch. able entrance plates are also standard on the 1600 and 000 amp units to install optional side-mounted pull boxes for additional cable bending space. Fig. : SO Power Transfer Switch rated 00 amperes Fig. : SO Power Transfer Switch rated 400 amperes Fig. 4: SO Power Transfer Switch rated 600 mperes Fig. 5: SO Power Transfer Switch rated 1000 amperes Fig. 6: SO Power Transfer Switch rated 000 amperes shown in Type R enclosure Fig. 7: SO Power Transfer Switch rated 000 amperes 5

6 SRIS 00 Microprocessor ontroller The SO Microprocessor ontroller is used with all sizes of Power Transfer Switches. It represents the most reliable microprocessor controller in the industry and includes, as standard, all of the voltage, frequency, control, timing and connectivity functions required for most emergency and standby power applications. Fig. 8: SO SRIS 00 Microprocessor ontroller Fig. 9: Door-Mounted ontrol & Display Panel ontrol and Display Panel asy-to-read flush-mounted control and display panel provides LD indicators for switch position and source availability. It also includes test and time-delay bypass switches. Voltage & Frequency Sensing djustable three-phase, close-differential voltage sensing on normal source. ormal source pickup voltage is adjustable to 95% of nominal; drop-out is adjustable from 70% to 90% of nominal. Frequency sensing on emergency source. Pickup at 95% and dropout at 85% of nominal. Time Delays djustable time delay to override momentary normal source outages to delay all transfer switch and enginestarting signals. Transfer to emergency time delay djustable from 0 to 5 minutes for controlled timing of load transfer to emergency. Retransfer to normal time delay djustable to 0 minutes. Five-minute unloaded running time delay for emergency engine generator cool down. Four-second time delay to ignore momentary voltage and frequency transients during initial genset loading. Standard Selectable Features Inphase monitor to transfer motor loads, without any intentional off time, to prevent inrush currents from exceeding normal starting levels. ngine exerciser to automatically test backup generator each week Includes control switch for testing with or without load. Selective load disconnect, double-throw contact to operate at an adjustable 0 to 0 second adjustable time delay prior to transfer and reset 0 to 0 seconds after transfer. 60 Hz or 50 Hz selectable switch. Three-phase/single-phase selectable switch. Remote ontrol Features Terminal provisions for connecting: Remote test switch. Remote contact for test or for peak shaving applications. ircuit will be automatically bypassed if emergency source fails. Inhibit transfer to emergency. Remote time-delay bypass switch. 6

7 SRIS 00 Microprocessor ontroller attery to Maintain ngine xerciser lock Settings Simple and ccurate djustment of Voltage, Frequency and Time-Delay Settings Without eed for Meters and Variable Power Supplies Dip Switches for nabling uilt-in ontrol Functions ustomer ontrol Interfaces Retransfer to ormal djustable Time Delay Transfer to mergency djustable Time Delay Serial ommunication Port Fig. 10: Microprocessor ontroller Performance Features 600 volt spacing per UL and S standards. Interfacing relays are industrial grade, plug-in type with dust covers. Meets or exceeds the requirements for lectromagnetic ompatibility (M). SI 7.90/I47 Voltage Surge Test M IS Impulse Withstand Test Digital circuitry isolated from line voltages I 801- lectrostatic discharge (SD) immunity V50140 and I 80-1: Radiated electromagnetic field immunity I lectrical fast transient (FT) immunity V5014 Surge transient immunity V50141: onducted radio-frequency field immunity 55011: Group 1, lass conducted and radiated emissions Optically isolated RS-485 Serial Port voltage dips and interruptions immunity 7

8 SRIS 00 TS Optional ccessories ccessory 11G programmable engine exerciser that provides for weekly or bi-weekly operation, includes one form contact for source availability of normal and one contact for availability of emergency (contact rating 0 Vdc, Vac resistive). The programmable engine exerciser incorporates a 7 day or 14 day time base with a digital readout display. Includes with or without load control selection for exerciser period. ccessory 14 /14 uxiliary contacts to indicate position of main contacts.two () for normal and two () for emergency position (one set is standard). ccessory 44 Strip Heater with thermostat for extremely cold areas to prevent condensation and freezing of this condensation. xternal 10 volt power source required. Fig. 11: Programmable ngine xerciser with Source vailability ontacts (ccessory 11G) ccessory 44G Strip Heater with thermostat, wired to load terminals: 08-40, 60-80, , volts. ontains wiring harnesses for all transfer switch sizes. ccessory 7 /7 *See Power onnectivity Products, Page 18 ccessory 1 protective window that includes a polycarbonate frame and weather gasket to provide secure access to the membrane interface for the type 1 enclosures.this lockable cover is an alternative to providing R secure enclosures. Fig. 1: Strip Heater Kit (ccessory 44G) Field onversion Kits for SRIS 00 Transfer Switches Kit o. Description K6980 ngine xerciser and source availability contacts (cc. 11G) K Strip Heater Kit (15 watt) 10 volt (cc. 44) K Strip Heater Kit (15 watt) volt (cc. 44G) K60907 able Pull ox ( amp) K FT xtension Harness 1 K Serial Module with or without power manager (cc. 7) K onnectivity Module with or without power manager (cc. 7) K Window Kit (cc. 1) 1. For 0-00 mp switches only, not available for 00S, or 00L Fig. 1: Window Kit (ccessory 1) 8

9 SRIS 86 on-utomatic Power Transfer Switches User-Initiated ontrol SO 86 non-automatic transfer switches are generally used in applications where operating personnel are available and the load is not an emergency type requiring automatic transfer of power. The power-switching mechanism and controller is the same hardware used on the highly reliable SO SRIS 00 transfer switches. SO 86s are furnished as standard with a momentary-type selector switch to initiate transfer and retransfer. They can also be arranged for remote control via SO s connectivity products. Fig. 14: SO mp Type 1 w/optional ccessories 9, 9D Source vailability Lights Fig. 15: ontrol and Display Panel lectrical Features: Listed under UL 1008, S certified: - UL listed through 480 V. - S certified through 600 V. Door-mounted selector switch for local, manually initiated electrical control. Sizes from 0 through 000 amps. vailable to 600 V, 50 or 60 Hz. Rated for all classes of load transfer. 100% tungsten load ratings through 400 amps. Designed for emergency and standby applications. Same withstand and close-on rating as SRIS 00. Standard Selectable ontrol Features: Inphase monitor to transfer motor loads between live sources, without any intentional off time, to prevent inrush currents from exceeding normal starting levels. Selective load disconnect, double-throw contact to operate at an adjustable 0 to 0 second time delay prior to transfer and reset 0 to 0 seconds after transfer. High/Low nominal voltage setting. llows user to adjust for source low reduced voltage conditions in remote areas. 60 Hz or 50 Hz selectable switch. Single/Three-phase selectable switch. ontrol Features: Switch position indicating signal lights. One auxiliary contact closed when transfer switch is connected to normal and one closed on emergency, standard feature 14/14. Optional ccessories: 6Q Key-operated, momentary source selector switch furnished instead of the standard selector switch. 9, 9D Source availability lights to provide operator with a local indication of power source availability. ccessory 14/14 auxiliary contacts to indicate position of main contacts. Two () for normal position and two () for emergency position (one set is standard). 7 Serial module (5110) is used to allow local or remote communications with SO PowerQuest VPi orsiteweb connectivity products. Special s (Specify by appropriate code in catalog number): Type R: Raintight Type 4: Weatherproof Type 1: Oil Tight 7 onnectivity Module 5150 is used to bring several different serial devices that communicate at different baud rates and with different protocols to a common thernet media. 9

10 SRIS 00 & 86 Transfer Switch Ordering Information To order an SO SRIS 00 Power Transfer Switch, complete the following catalog number: X D + 480V 60Hz Product eutral ode Poles mperes Voltage ode ontroller Options lank Open Type Optional ccessories Specific Volt & Freq 00 lank Solid eutral 1 Switched eutral poles, 1Ø poles, Ø ontinuous rating 0, 70, 104, 150, 00 4, 0 4, 60, 400, 600, 800, 1000, 100, 1600, , D F H J K L M Q R Insert X If optional accessories are required F G H L M Type 1 (Standard) Type R Type 4 Type 4X Type 1 Type R Secure Type 4 Secure 11G Programmable ngine xerciser 14/14 uxiliary ontacts ( sets) 44, 44G Strip Heater w/thermostat 7 Serial Module 7 onnectivity Module 1 Window Kit This information is necessary to allow correct control settings prior to shipment To order an SO SRIS 86 Transfer Switch, complete the following catalog number: X + + 9/9D + 480V 60Hz Product eutral ode Phase Poles mperes Voltage ode ontroller Options lank Open Type Optional ccessories Specific Volt & Freq 86 Solid eutral 1 Switched eutral poles, 1Ø poles, Ø ontinuous rating 0, 70, 100, 150, 00 4, 0 4, 60, 400, 600, 800, 1000, 100, 1600, 000, D F H J K L M Q R Insert X If optional accessories are required F G H L M Type 1 (Standard) Type R Type 4 Type 4X Type 1 Type R Secure 6Q Key-Operated ontrol 9/9D Source vailability Lights 14/14 uxiliary ontacts 7 Serial Module ll ccessories 7 onnectivity Module This information is necessary to allow correct control settings prior to shipment ote: 1. Specify neutral code for 60 and 400 amperes only.. vailable , and 1600 amps. Use Type R for 100, 000, 600 and 000 amp applications volt available amps only. For other voltages contact SO and 0 amp rated switches for use with copper cable only. 5. Secure R type provided as standard for amp when outdoor enclosure is required. xtended Warranties for SRIS 00 Transfer Switches 10 atalog o. XW00 XW00 4XW00 5XW00 Description Two-Year xtended Warranty (Parts & Labor) Three-Year xtended Warranty (Parts & Labor) Four-Year xtended Warranty (Parts & Labor) Five-Year xtended Warranty (Parts & Labor)

11 SRIS 00 & 86 Transfer Switch Dimensions and Shipping Weights UL Type 1 (See notes below for information on Type R, 4 & 1 s) Switch Rating amps 0, 70, 100*, , 00 *SRIS 86 only 0, 60, , , 000 1,6 600, 000 Phase Poles eutral ode 7 or 7 or Dimensions, In. (mm) Width Height Depth 17 1/ (445) 17 1/ (445) 17 1/ (445) 17 1/ (445) 18 (457) 18 (457) 18 (457) 18 (457) 4 (610) 4 (610) 4 (610) 4 (610) 4 (864) 4 (864) 4 (864) 4 (864) 8 (965) 8 (965) 8 (965) 8 (965) 8 (965) 8 (965) 8 (965) 8 (965) otes: 1. Unit is designed for top cable entry of emergency & load and bottom entry of normal. cable pull box is also available for all top or bottom cable access when required (optional accessory kit #K60907). ot required for type R, 4X & 1 enclosures where available.. s for 600, 000 amps are free-standing with removable top, sides & back.. For type R, 4X & 1 dimensions, add the following values to the type 1 dimensions: a) 0, 70, 100, 104, 150, 00 add 1.5 in (8 mm) to the height. b) 0, 60, add 1.5 in (8 mm) to the depth. c) 100 type 4, 4X & 1 not available use 1600 amp switch d) 1600, 000 add in (76 mm) to the height and 10 in to (5mm) to the width. e) 600, 000 type 4X & 1 not available. (onsult SO) Type R add 4.68 in (118 mm) to the height add.0 in (51 mm) to the width and add 1 in (9 mm) to the depth. 1 (787) 1 (787) 1 (787) 1 (787) 48 (119) 48 (119) 48 (119) 48 (119) 6 (1600) 6 (1600) 6 (1600) 6 (1600) 7 (189) 7 (189) 7 (189) 7 (189) 87 (10) 87 (10) 87 (10) 87 (10) 87 (10) 87 (10) 91 (11) 91 (11) 11 5/8 (95) 11 5/8 (95) 11 5/8 (95) 11 5/8 (95) 1 (0) 1 (0) 1 (0) 1 (0) 17 (4) 17 (4) 17 (4) 17 (4) 0 (508) 0 (508) 0 (508) 0 (508) 4 (610) 4 (610) 4 (610) 4 (610) 4 (610) 4 (610) 60 (154) 60 (154) pprox. Shipping Weight Lb. (kg)4 69 () 7 () 7 () 75 (4) 100 (45) 110 (50) 100 (45) 10 (55) 6 (119) 70 (1) 70 (1) 77 (16) 450 (04) 475 (17) 475 (17) 500 (8) 685 (1) 705 (1) 705 (1) 75 (8) 95 (419) 975 (441) 1700 (771) 15 (969) 4. For type R, 4X & 1 weights, add the following values to the type 1 weights: a) 0, 70, 100, 104, 150, 00 add 15 lbs. (6.8 kg). b) 0, 60, 400, 600, 800, 1000 add 40 lbs. (18.1 kg). c) 1600 add 60 lbs. (7 kg). d) Type 4 & 1 not available. (onsult SO) 5. When temperatures below ºF can be experienced, special precautions should be taken, such as the inclusion of space heaters, to prevent condensation and freezing of this condensation. This is particularly important when environmental enclosures (Type R, 4 & 1) are ordered for installation outdoors. 6. Front connected design for 00 s and 86 s. on secure enclosure for type R, 4X and 1 provided as standard. 7. eutral ode for 0 amperes only. SO SRIS 00 & 86 xternal Power onnections Sizes UL-Listed Solderless Screw-Type Terminals Switch Rating (amps) , , 1000, , , 000 Ranges of L-U Wire Sizes (Unless Specified opper Only) One #14 to 4/0 WG Two 1/0 WG to 50 MM or One #4 WG to 600 MM Two /0 WG to 600 MM Four 1/0 to 600 MM Six 1/0 to 600 MM Twelve /0 to 600 MM ote: 1. ll SRIS 00 switches are furnished with a solid neutral plate (unless switched neutral configuration is specified) and terminal lugs. Specify in catalog number to order a neutral plate on the series 86 switches.. 00 and 0 amp rated switches for use with copper cable only. Refer to paragraph of the for additional information.. Use wire rated 75 o minimum for all power connections. 11

12 SRIS 00S Power Transfer Switch The SO Service ntrance Power Transfer Switch ombines automatic power switching with a utility circuit breaker as a disconnect device. The power transfer switch meets all ational lectrical ode requirements for installation as service entrance equipment. Service entrance rated transfer switches generally are installed at facilities that have a single utility feed and a single emergency power source. circuit breaker serves as the utility disconnect and links are provided to connect both neutral and ground conductors. The SO 00S Service ntrance utomatic Transfer Switch uses the same reliable transfer switching mechanism and controller as the SRIS 00 product platform, and also includes a utility circuit breaker as a disconnect device. Fig. 16: SO Service ntrance Power Transfer Switch rated Pole 800 amperes shown in Type R enclosure Load Ground Disconnect Link eutral Disconnect Link Ground Fault urrent Transformer * Transient Voltage Surge Supressor (Optional) Switched eutral Utility mergency ircuit reaker utomatic Transfer Switch One line diagram of a typical service entrance rated transfer switch available in Solid or Switched eutral.*ground fault trip protection provided on sizes of 1000 amperes and above Product Features: Suitable for use as service entrance equipment. The SO SRIS 00S is listed to UL 891 standard for Dead-Front Switchboards, and meets all requirements for service entrance equipment. utomatic Transfer Switch is listed to UL 1008 for total system loads. Sizes available from 70 through 000 amps. vailable to 600 V, 50 or 60Hz, single or three phase. ircuit reaker disconnect on the normal for isolation of transfer switch and other electrical equipment. Disconnect link on eutral and Ground. Silver plated copper ground and neutral bus. Solderless screw type terminals for xternal Power onnections. Ground fault trip protection provided on sizes of 1000 amperes and above. UL approved Type 1 enclosure. Fig. 17: Ground and neutral UL approved Type R secure enclosure. disconnect links vailable with solid or switched neutral. Optional TVSS vailable on ormal, mergency and/or Load. SO To order an SO SRIS 00S Power Transfer Switch, complete the following catalog number: US X D + 40V/60 Product US eutral ode 1 Switched eutral SRIS 00S Transfer Switch Ordering Information Phase Poles poles, 1Ø poles, Ø mperes ontinuous Rating 70, 100, 150, 00, 5, 50, 400, 600, 800, 1000, 100, 1600, , 000 Voltage ode D F H J K L M Q R ontroller Options 1 Insert X If optional accessories are required lank M Q Open Type Type 1 (Standard) Type R Secured Type 4 Secured Type 1 Secured Optional ccessories 11G Programmable ngine xerciser 14/14 uxiliary ontacts ( sets) 44G Strip Heater w/thermostat 7 Serial Module 7 onnectivity Module 7 Surge Suppressor Specific Volt & Freq This information is necessary to allow correct control settings prior to shipment ote: 1. Specify neutral code for 50 and 400 amperes only.. vailable ampacity. Use Type R for amp applications volt available amps only solid neutral is standard on US.

13 UL Type 1 (Dimensional data is approximate and subject to change. ertified dimensions available upon request.) Switch Rating amps 70, 100,150, 00, 5 50, , , , , SRIS 00S Transfer Switch Dimensions and Shipping Weights Phase Poles eutral ode Dimensions, In. (mm) Width Height Depth 6.5 (97) 48.5 (1) 1.5 (7) 6.5 (97) 48.5 (1) 1.5 (7) 6.5 (97) 48.5 (1) 1.5 (7) 6.5 (97) 48.5 (1) 1.5 (7) 6.5 (97) 48.5 (1) 1.5 (7) 6.5 (97) 48.5 (1) 1.5 (7) 6.5 (97) 48.5 (1) 1.5 (7) 6.5 (97) 48.5 (1) 1.5 (7) 8 (965) 91 (11) 8 (711) 8 (965) 91 (11) 8 (711) 8 (965) 91 (11) 8 (711) 8 (965) 91 (11) 8 (711) 8 (965) 91 (11) 48 (118) 8 (965) 91 (11) 48 (118) 8 (965) 91 (11) 48 (118) 8 (965) 91 (11) 48 (118) 8 (965) 91 (11) 48 (118) 8 (965) 91 (11) 48 (118) 8 (965) 91 (11) 7 (189) 8 (965) 91 (11) 7 (189) pprox. Shipping Weight Lb. (kg) 400 (185) 408 (188) 408 (188) 416 (19) 400 (185) 408 (188) 408 (188) 416 (19) 800 (70) 80 (78) 80 (78) 846 (90) 1085 (501) 1105 (510) 1105 (510) 114 (5) 590 (1198) 640 (118) 4590 (118) 4655 (148) UL Type R (Dimensional data is approximate and subject to change. ertified dimensions available upon request.) Switch Rating amps 70, 100,150, 00, 5 50, , , , , Phase Poles eutral ode Dimensions, In. (mm) Width Height Depth 6.5 (97) 49.5 (151) 16 (406) 6.5 (97) 49.5 (151) 16 (406) 6.5 (97) 49.5 (151) 16 (406) 6.5 (97) 49.5 (151) 16 (406) 6.5 (97) 49.5 (151) 16 (406) 6.5 (97) 49.5 (151) 16 (406) 6.5 (97) 48.5 (151) 16 (406) 6.5 (97) 48.5 (151) 16 (406) 8 (965) 91 (11) 6.5 (91) 8 (965) 91 (11) 6.5 (91) 8 (965) 91 (11) 6.5 (91) 8 (965) 91 (11) 6.5 (91) 40 (1016) 91 (11) 6 (1575) 40 (1016) 91 (11) 6 (1575) 40 (1016) 91 (11) 6 (1575) 40 (1016) 91 (11) 6 (1575) 6 (157) 95 (41) 6 (1575) 6 (157) 95 (41) 6 (1575) 41 (1041) 95.5 (46) 74 (1880) 41 (1041) 95.5 (46) 74 (1880) pprox. Shipping Weight Lb. (kg) 58 (48) 546 (5) 546 (5) 554 (56) 58 (48) 546 (5) 546 (5) 554 (56) 990 (458) 1010 (467) 1010 (467) 106 (479) 105 (604) 15 (61) 15 (61) 154 (66) 890 (17) 940 (160) 550 (474) 5415 (504) ote: 1. Unit is designed for top and bottom cable entry for all services and load.. s for amps are freestanding.. When temperatures below F can be experienced, special precautions should be taken, such as the inclusion of strip heaters, to prevent condensation and freezing of this condensation. This is particularly important when environmental enclosures (Type R, 4 & 1) are ordered for installation outdoors. See Optional ccessories page for space heater options (acc. 44G). xtended Warranties for SRIS 00S Transfer Switches atalog o. XW00S XW00S 4XW00S 5XW00S Description Two-Year xtended Warranty (Parts & Labor) Three-Year xtended Warranty (Parts & Labor) Four-Year xtended Warranty (Parts & Labor) Five-Year xtended Warranty (Parts & Labor) SRIS 00S I Rating Switch Rating I Rating 70, 100, 150, 00, 5 5,000 50, 400 5, , 800, 1000,100, 1600, , , ,000 SRIS 00S xternal Power onnections Sizes UL-Listed Solderless Screw-Type Terminals Switch Rating 70, 100, 150, 00 *, 5 * 50, , 1000, , Ranges of L-U Wire Sizes (Unless Specified opper Only) One #14 to 4/0 WG Two 1/0 WG to 50 MM or One #4 WG to 600 MM Two 1/0 WG to 600 MM Four 1/0 to 600 MM Six 1/0 to 600 MM Twelve /0 to 600 MM Twelve /0 to 600 MM ote: ll SRIS 00S switches are furnished with a solid neutral plate (unless switched neutral configuration is specified) and terminal lugs. * 00 and 5 amp rated switch for use with copper cable only. 1

14 SRIS 00L Power Transfer Load enter The SO Power Transfer Load enter verything that is needed to protect sensitive loads from power outages and transients is in one package, the SO SRIS 00 utomatic Power Transfer Switch with microprocessor digital controller. Versatile Square D Load Distribution Panel, and protective transient voltage surge suppression for normal and emergency. SO utomatic Transfer Switches are the standard of the industry and represent the most advanced technology in transferring loads between two power sources. vailable with 00 or 400 mp rating, 10/40 V 60 hz single phase, wire or 10/08 V, 60 hz three phase, 4 wire. The PTL includes a 4-position load distribution panel. Main circuit breakers provide overcurrent protection and disconnect for convenient and safe serviceability. The shallow profile facilitates installation. When power fails, the automatic transfer switch follows user-set time delays to start the generator, transfer the load to the generator, reconnect to utility power and shut down the generator after generator cool down. Fig. 18: SRIS 00 L Power Transfer Load enter Features Power Transfer Load enter is Service ntrance Rated and listed to UL67 utomatic Transfer Switch is listed to UL1008, the standard for Transfer Switch quipment, and meets FP 110 for mergency and Standby Power Systems and the ational lectrical ode () articles 700, 701 and 70. lso S certified to S. o True double-throw contacts eliminate simultaneous connection to utility and generator djustable close differential voltage sensing on the normal source utomatic engine exerciser to test the generator with or without loads. This is optional accessory 11G on standard SRIS 00 products Pre-wired and factory tested for easy installation Transient Voltage Surge Suppression (TVSS) Technology Parallel rrayed Metal Oxide Varistors Maximum continuous operating voltage (MOV) 15 Percent of Line Voltage Mode Protection ll mode protection ( L-, L- G, L- L, - G ) Surge urrent 90k (8/0us) Transient waveform for category Surge Voltage Rating (8/0us), 400v (L-, L- G, - G, 700volts (L-L) Overurrent Protection 00 amps 400 amps larming Remote - Two () Form contacts rated 5 amps at 10 vac Visual - LD protection indicators for each phase Space saving modular design provides easy access and serviceability onvenient terminals for connecting neutral and ground conductors 14 vailable in Type 1 (indoor) or Type R (non-secure outdoor) enclosures

15 SRIS 00L Power Transfer Load enter Ordering Information To order an SO SRIS 00L Power Transfer Load enter, complete the following catalog number: 00L F X + Product 00L Load enter 4 = 4 ircuits Poles poles, 1Ø poles, Ø mperes ontinuous Rating F Voltage ode 08/10v/60hz Ø 4 wire 40/10v/60hz 1Ø wire ontroller Options 1 Insert X If optional accessories are required 11G Programmable ngine xerciser and Source vailability ontacts F Type 1 (Standard) Type R on-secure 14/14 uxiliary ontacts 1 44G Strip Heater w/thermostat 7 Serial Module 7 onnectivity Module 7 Transient Voltage Surge Suppression 7V*1 single phase or 7V* three phase ote: 1. uxiliary contacts indicate position of main contacts. Two () for normal and two () for emergency position (one set is standard). Specify for Utility (1 required), for Utility and Generator ( are required), and L for Load (1 required) SO SRIS 00L Power Transfer Load enter Dimensions and Shipping Weights Switch Rating amps Phase Poles Type Type 1 Type 1 Type R on Secure Type R on Secure Type 1 Type1 Type R on Secure Type R on Secure SRIS 00L Power Transfer Load enter Sizes UL-Listed Solderless Screw-Type Terminals Switch Rating Ranges of L-U Wire Sizes (Unless Specified opper Only) One #14 to 4/0 WG Two 1/0 WG to 50 MM or One #4 WG to 600 MM Dimensions, In. (mm) Width Height Depth 0 (76) 66 (1675) 6 (15) 0 (76) 66 (1675) 6 (15) 0 (76) 84 (1) 10 (54) 0 (76) 84 (1) 10 (54) 5 (888) 78 (1980) 7.5 (184) 5 (888) 78 (1980) 7.5 (184) 0 (76) 84 (1) 10 (54) 0 (76) 84 (1) 10 (54) xtended Warranties for SRIS 00L Power Transfer enter Switches atalog o. XW00L XW00L 4XW00L 5XW00L pprox. Shipping Weight Lb. (kg) 55 (118) 59 (10) 17 (146) 1 (148) 90 (14) 98 (18) 5 (16) 60 (166) Description Two-Year xtended Warranty (Parts & Labor) Total years Three-Year xtended Warranty (Parts & Labor) Total years Four-Year xtended Warranty (Parts & Labor) Total 4 years Five-Year xtended Warranty (Parts & Labor) Total 5 years Field onversion Kits for SRIS 00L Transfer Switches Kit o. Description K Single Phase Surge Suppression 40v/10v (cc. 7V*1) K74-00 Three Phase Surge Suppression 09v/10v (cc. 7V*) ote: 1. onsult SO for Type R secure enclosures 15

16 SRIS 00 Power Monitoring & ontrol SO onnectivity Solutions SO PowerQuest and SiteWeb communications products allow for the monitoring and control of power transfer switches in your mergency or Standby Power Distribution System. Local rea etworks and Remote networks are supported with either single or multiple points of access and web-enabled communications allow access to your power system from anywhere around the world. Features Monitors and controls Power Transfer Switches and ngine Generators Monitors normal and emergency voltages and frequency Indicates transfer switch position and source availability Provides transfer and re-transfer of loads for system testing View normal and emergency voltage and frequency settings View transfer switch time-delay settings Provides transfer switch rating and identification utomatic paging notifies personnel, by or text message, of selected system alarms View current, power and power factor with SO Power Managers connected to the system PowerQuest Typical etwork onnection Dial - Up SO 5110 (7) Serial Modules TIM Power Manager Generator To dditional utomatic Transfer Switches PowerQuest VPi.15 Software SO TS 1 SO TS SO 5110 (7) Serial Modules Serial RS-485 Power Manager Generator To dditional utomatic Transfer Switches SO TS 1 SO TS 16

17 SRIS 00 Power Monitoring & ontrol Local omputer Remote ccess omputer thernet RS 485 thernet Hub Firewall Internet Pager Monitoring and ontrol SO 5500 Thin Web Server thernet mail Server TS nnunciator RS 4 Modbus RS 485 uilding Management omputer (7) Monitoring and ontrol SO 4000 Series Power ontrol System thernet Hub Monitoring SO 5110 (7) Serial Modules SO 5150 (7) onnectivity Modules To dditional utomatic Transfer Switches To dditional utomatic Transfer Switches SO TS 1 SO TS SO TS 1 SO TS SiteWeb is a client-server application requiring no software to be installed on the client computer. When combined with the SO ommunication Interface Modules (cc 7, cc 7), and the SO 5500 SRIS Thin Web Server provide the most comprehensive Intranet and Internet communication system for the monitoring and control of power transfer switches and engine generators located in your emergency or standby power distribution system. The SiteWeb communication system allows multiple client access, from local or remote locations, and provides for the monitoring of up to 64 power transfer switches and eight engine generators. In addition, automatic paging is provided for all alarm signals. 17

18 SRIS 00 Power onnectivity Products PowerQuest vs. SO onnectivity Solution Guide Feature Quantity of Monitored / ontrolled Power Transfer Switches per L umber of Monitored / ontrolled Gensets ontrol & Monitoring apability mbedded Web Pages thernet etwork ompatible Monitor Multiple Protocols & aud Rates (SO I, SO II, Modbus) Monitor Multiple Sites Multiple lient ccess lient Software Required Monitors Dissimilar SO ontrollers on ommon L ommunicates with SO Remote nnuciators mail / Paging larms Historical Trending Option larms PowerQuest VPi.15 4 o o Dial-Up o o o o o Thin Web Server with SiteWeb 5150 onnectivity Module 64 8 o Internet Up to 8 Internet xplorer o o o Intranet Up to 8 Internet xplorer o o 5110 Serial Module at. o: 5110 cc. o: 7 Fig. 19: Serial Module The Serial Module (5110) is used to allow local or remote connectivity with SO PowerQuest or SiteWeb connectivity products. The module is used to connect SRIS 00 transfer switches to a serial network via an RS-485 interface. The module has two port connectors used for TS & Stand-alone Power Manager connectivity. The serial connection is accomplished from a 5-pin terminal header/socket block. The serial network can support up to devices onnectivity Module at. o: 5150 cc. o: 7 Fig. 0: onnectivity Module The onnectivity Module (5150) is used to bring several different serial devices that communicate at different baud rates and with different protocols to a common thernet medium. The module is used to connect SRIS 00 transfer switches to a standard 10aseT thernet TP/IP network using standard RJ-45 connectors. The module contains built in JV TM applets (program applications for an internet browser) for each monitored device that can load automatically to a standard Web rowser. The module is designed to communicate with up to 8 clients such as Web rowsers, and PowerQuest systems simultaneously over the ethernet connection. 18 Fig. 1: Telephone Interface Module 510 SRIS Telephone Interface Module at. o: 510 The SO Telephone Interface Module (TIM) allows users to dial directly into their SO communications network for monitoring and/or control. The TIM connects to the SO communication network via RS-485 and the phone port connects directly into an analog phone jack. lso, the TIM has an RS- connector which allows the TIM to be used as the dialing modem. Supplied with 10 V to 18 VD (nominal) UL approved, class power supply.

19 TS 1 TS TS TS 4 TS 5 TS 6 TS 7 TS 8 SO SRIS 00 Power onnectivity Products SO 1901 lavg 548 KW 08 Vca 0 Vca L Fig. : utomatic Transfer Switch nnunciator 1901 lavg 548 KW L 1901 lavg 548 KW 1901 lavg 548 KW 1901 lavg 548 KW 1901 lavg 548 KW Fig. 4: Thin Web Server 1901 lavg 548 KW Fig. 5: SO 500D SRIS Power Manager 47 lavg 16 KW OTTS OTTS OTTS OTTS OTTS OTTS OTTS OTTS Previous 08 Vca 0 Vca ngine 1 Stopped ngine Stopped ngine Stopped ngine 4 Running 0 KW Total 0.00 Frequency 0.00 Power Factor 0 Vavg. 0 lavg. Transfer TS 1-8 Summary Screen 08 Vca 0 Vca L Re-Transfer 08 Vca 0 Vca L 0 KW Total 0.00 Frequency 0.00 Power Factor 0 Vavg. 0 lavg. L TD ypass 08 Vca 08 Vca L Re-Scan 08 Vca 08 Vca 0 KW Total 0.00 Frequency 0.00 Power Factor 0 Vavg. 0 lavg. 08 Vca 08 Vca L Fig. : SO PowerQuest Vpi.15? 0 Vca 08 Vca L TS KW Total Frequency 0.8 Power Factor 08 Vavg. 47 lavg. utomatic Transfer Switch nnunciator at. o: The SO TS nnunciator is a stand alone device capable of providing individual status annunciation for up to four transfer switches. Separate LDs indicate switch status and position. Separate push buttons individually initiate transfer switch operation and testing. Transfer switch annunciators can also be set up in multiple locations to monitor the same devices, allowing for redundant annunciation of business-critical transfer switches. PowerQuest VPi.15 VPi.15 is a P based monitoring and control system for SO devices. The local RS-485 network connects with up to Power Transfer Switches and four ngine Generators. n analog phone connection and SO Telephone Interface Module allow for direct dial up, monitoring and control of remote locations. When combined with the SO 5110 Serial Module (cc. 7), the SO 510 Telephone Interface Module, and the SO 500 SRIS Power Manager, it provides the most economical communications system for monitoring and controlling Power Transfer Switches and ngine Generators SRIS Thin Web Server at. o: 5510 The SO Thin Web Server allows you to monitor and control transfer switches and engine generators anytime over the Internet or an Intranet from anywhere in the world. It also transmits an message that an alarm has occurred with one or more of the transfer switches. Plus, this is possible from your home computer or anywhere that has Internet service, using the SO Thin Web Server with its embedded SiteWeb HTML web pages. 500 SRIS Power Manager at. o: 50D The SO 500 SRIS Power Manager is a microprocessor metering device specifically designed for transfer switch applications to provide real-time measurements of single and three-phase power systems. It uses digital signal processing technology to measure voltage and phase currents, which it uses to calculate real, reactive, and apparent power and bidirectional energy. ll measurements can be displayed locally or at a remote P via PowerQuest or SiteWeb. It can also collect data for both normal and emergency positions using auxiliary contact inputs from the transfer switch. ight digital input and four digital outputs available for customer use. The SO 500 SRIS Power Manager is available with or without a stand alone M 1 enclosure. 19

20 SO Power Technologies FLORHM PRK, W JRSY 079 US SO SI USTRLI RZIL D GRMY JP MXIO SOUTH FRI SOUTH MRI UITD R MIRTS UITD KIGDOM UITD STTS merson etwork Power. The world leader in business-critical continuity. Power mbedded Power onnectivity Inbound Power D Power Integrated abinet Solutions Outside Plant Precision ooling Site Monitoring and Services mersonetworkpower.com merson etwork Power and the merson etwork Power logo are trademarks and service marks of merson lectric o. 005 merson lectric o. Publication 1195 R10 January, 006 Printed in the U.S..

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

Continuous Power... Continuous Protection

Continuous Power... Continuous Protection Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment

More information

Surgelogic Surge Protective Device (SPD)

Surgelogic Surge Protective Device (SPD) Surgelogic Surge Protective Device () EB, EM, and HW Series atalog 1310T0202R05/09 2009 lass 1310 OTETS Description............................................. Page Product Description...........................................2

More information

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

Surgelogic Surge Protection Device EMA, EBA, and HWA Series Surgelogic Surge Protection Device EM, EB, and HW Series atalog 1310T0202R5/07 2007 lass 1310 OTETS Description..............................................Page Product Descriptions..........................................

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

GTEC transfer switch open transition

GTEC transfer switch open transition GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility

More information

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply

How To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in

More information

Contents. Clean Control Center Harmonic Correction Unit. Selection Dimensions Specifications. Description

Contents. Clean Control Center Harmonic Correction Unit. Selection Dimensions Specifications. Description lean ontrol enter Harmonic orrection Unit Technical Data Selection Dimensions Specifications ontents Description Page lean ontrol enter Specifications Harmonic orrection Unit...... 2 Sizing and Selection...........................................

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

How To Test A Power Switch On A Power Supply

How To Test A Power Switch On A Power Supply transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability

More information

Transfer Equipment Controls

Transfer Equipment Controls Control Types Manual Transfer Switches Nonautomatic Transfer Switches Automatic Transfer Switches The type of control system for the transfer switch will vary depending on the type of switching equipment

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142

More information

Alliance System Ordering Guide

Alliance System Ordering Guide Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

3500/22M Transient Data Interface

3500/22M Transient Data Interface 3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

POWER GENERATION. www.mtu-online.com

POWER GENERATION. www.mtu-online.com POWER GENERATION A TOGNUM GROUP BRAND Valid for north america Europe / Middle East / Africa / Latin America MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax + 49 7541

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This

More information

Transfer switch BTPC open, closed or delayed transition

Transfer switch BTPC open, closed or delayed transition Transfer switch BTPC open, closed or delayed transition 150-4000 Amp Description The Cummins Power Generation BTPC series bypass isolation transfer switch combines an automatic transfer switch with a drawout

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

Combination Starters. Class 8538/8539, 8738/8739

Combination Starters. Class 8538/8539, 8738/8739 ombination Starters lass 88/89, 878/879 ONTNTS Description Page General Information ombination Starters Rated pplication Data pproximate Dimensions and Shipping Weights.. 7 Panel Layout Drawings. Reversing

More information

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS 1. Description and Phone Number Dialing: The dialer shall be a solid state component capable of dialing up to 16 telephone numbers, each up to 60 digits

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

Applications. Remote Display Mounting Kits

Applications. Remote Display Mounting Kits June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Power Management Module 2. Installation

Power Management Module 2. Installation Power Management Module 2 30 300 kva Installation Table of Contents Safety... 1 Safety Instructions... 1 Certification Standards Three Phase... 1 Product Safety... 2 Special Precautions... 2 System Description...

More information

Specification Requirements DBL 700MX and 1000MX Series UPS

Specification Requirements DBL 700MX and 1000MX Series UPS Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

SWITCHGEAR. EGP Switchgear

SWITCHGEAR. EGP Switchgear SWITCHEA EP Switchgear Cat generator set paralleling switchgear has been designed to integrate with Cat EMCP3 generator set controls. Now you can get greater efficiency, reliability and dependability all

More information

Back-UPS Pro 1300/1500 Installation and Operation

Back-UPS Pro 1300/1500 Installation and Operation Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

CPS 100 480Y S K CPS 100 480Y S C

CPS 100 480Y S K CPS 100 480Y S C Ref. No. 1299 Visor Series Ordering Guidelines Table.1-4. Retrofit Surge Protection Products TVSS General Description Clipper Power System Visor Series CPS 100 480Y S K.1-9 Surge Ratings 100 = /phase 120

More information

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03 PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

Mains. Assembly SCCRs. Voltage ratings. Bus amperages. Branch circuits. Panels. Through-lugs & loadside disconnect. Neutrals. Grounds.

Mains. Assembly SCCRs. Voltage ratings. Bus amperages. Branch circuits. Panels. Through-lugs & loadside disconnect. Neutrals. Grounds. Quik-Spec oordination Panelboard Specifications 11 PELORDS QuikShip ll SQSP configurations of the standard EM 1 enclosure can be specified for shipment within 10 business days of order when specified.

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility

EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility Catalog 2800CT1001 R09/15 2015 Class 2800 CONTENTS Description............................................ Page 2 Home

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

White Paper - July 2012. ATS021-ATS022 Automatic transfer switching

White Paper - July 2012. ATS021-ATS022 Automatic transfer switching White Paper - July 202 02-022 Automatic transfer switching 02-022 Automatic transfer switching Index. Introduction...2 2. Description of... Switching logics...6 Transformer for the main and generator

More information

5500 Series, Catalog A5510 Thin Web Server software version 5

5500 Series, Catalog A5510 Thin Web Server software version 5 5500 Series, Catalog A5510 Thin Web Server software version 5 Remote Monitoring & Control of Automatic Transfer Switches via the Internet or an intranet 4000 Series, 7000 Series, Series 300, and 940, 962,

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION

More information

T1 Backhaul Connectivity Solution All Products :: Application Note

T1 Backhaul Connectivity Solution All Products :: Application Note Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments

More information

Model #: SMART2200CRMXL

Model #: SMART2200CRMXL Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

Installation and Operation Back-UPS 1250, 1300, 1500

Installation and Operation Back-UPS 1250, 1300, 1500 Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with

More information

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U

More information

ATC-300 Automatic Transfer Switch Controller

ATC-300 Automatic Transfer Switch Controller ATC-300 Technical Data New Information Technical Data Page 2 Effective: May 2004 ATC-300 Introduction The Cutler-Hammer ATC-300 from Eaton s Electrical business is a comprehensive, multi-function, microprocessor-based

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert

More information

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify. SECTION 263354 STATIC UPS TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes 1. System start-up services. 2. Battery charging. 3. Load bank testing. 4. Battery load testing. 5.

More information

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous

More information

Communicate and view data from meters with one simple device

Communicate and view data from meters with one simple device Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click

More information

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS TR TSY 000757 GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS 1. Introduction.... 1.1 Purpose and Scope 1.2 Organization.. 1.3 Reason for Reissue From Technical Advisory

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Internet Office UPS System Standby UPS for PCs, workstations and more

Internet Office UPS System Standby UPS for PCs, workstations and more Internet Office UPS System Standby UPS for PCs, workstations and more Model #: INTERNETOFFICE500 500VA standby tower UPS system Offers battery-derived AC output during blackouts and brownouts starting

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

Mobile Data Power Model: MDP-25

Mobile Data Power Model: MDP-25 Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss

More information

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

Product Specification instalert Rapid Messenger Variable Message Sign

Product Specification instalert Rapid Messenger Variable Message Sign instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc. SiteRanger tm Comprehensive Broadband/ Enterprise site monitoring device for Headend s, Hub Sites. Power quality / site monitoring Focus on power system infrastructure Retrofit legacy devices for remote

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

NGC-30-CR -CRM -CRMS -CTM -CVM

NGC-30-CR -CRM -CRMS -CTM -CVM NG-0-R -RM -RMS -TM -VM ontrol and monitoring modules for use with the Raychem NG-0 Installation Instructions Description The NG-0-RM/-RMS and NG-0-TM provide ground-fault and line current sensing, alarming,

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more

More information

SUGGESTED SPECIFICATION for Service Entrance Automatic Transfer Switches

SUGGESTED SPECIFICATION for Service Entrance Automatic Transfer Switches PART 1 GENERAL 1.01 Scope SUGGESTED SPECIFICATION for Service Entrance Automatic Transfer Switches Division 16 - Electrical Standby Power Generator Systems A. Furnish and install service entrance automatic

More information

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1 Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

TOSHIBA G9000 80/100/160/225 kva

TOSHIBA G9000 80/100/160/225 kva CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA G9000 80/100/160/225 kva GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description Gas Genset Controls Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Description The Cummins Power Genset Control Panel (GCP2) is an integrated monitoring and control system for the Cummins

More information

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter

More information

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V

More information

Liebert PPC Second Generation Power Distribution Cabinet

Liebert PPC Second Generation Power Distribution Cabinet Liebert PPC Second Generation Power Distribution Cabinet Emerson Network Power Delivers The Packaged Power Solution Creating high quality power is a major step towards protecting the operation of a critical

More information

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion

More information