HOME INSPECTION REPORT
|
|
|
- May Lee
- 10 years ago
- Views:
Transcription
1 HOME INSPECTION REPORT Chicago St. Somewhere, IL Inspection Date: Prepared for: Client 123 W. Watertown 773/ Chicago, IL, 606 Prepared by: Markus Keller Accurate Inspections & Consulting (773) 844-4AIC Chicago, IL, 60643
2 2 ACCURATE INSPECTIONS & CONSULTING Inc. 773 / TABLE OF CONTENTS EXECUTIVE SUMMARY DEFECT SUMMARY HAZARDOUS CONDITIONS OVERALL BUILDING INFORMATION SOIL, VEGETATION & GRADING FOUNDATION STRUCTURAL ELEMENTS BASEMENT EXTERIOR ELEMENTS HVAC ELECTRICAL PLUMBING GENERAL INTERIOR ATTIC GARAGE BUILDING ACCESSORIES PURPOSE LIMITATIONS END OF REPORT
3 ACCURATE INSPECTIONS & CONSULTING Inc. Home inspections Housing court services Building assessments Scopes of Work Code compliance Project consulting 3 HOME INSPECTION REPORT Client Information: Client Inspection Property: Chicago, IL, 606 Phone # IL The following report describes conditions at the above listed property. An interior and exterior inspection was conducted, along with a visual and functional inspection of the mechanicals as possible. This report covers existing conditions observed, potential problems and related concerns that we recommend you take into consideration. Any items needing repair will likely need further evaluation by a contractor. Overall costs for all repair or replace recommendations by the Inspector are ballpark figures only and should be reviewed in determining the real cost of purchasing a particular property. Final proposals by contractors can vary greatly depending on the decisions you make and what is found inside of walls or ceilings. Contents of this report are covered in their entirety by the Agreement between the Client and Inspector. The executive summary is provided for your convenience. Please read the entire report and notes to get a full understanding of property conditions. The full report contains additional relevant information regarding conditions, systems and concerns at the property. The Building appears to be in overall poor condition. The basic structure, i.e. floors, walls, ceilings show excessive signs of age and wear. Various defects and conditions were found as outlined in this report. Inspection Date: Time: 1000 Weather: Cloudy / Rain Temperature: +/- 55 Recent rain: Yes Soil: Wet Water: ON partial Electric: ON Gas: ON Client present during inspection: YES Other s present during inspection: Buyers realtor
4 4 ACCURATE INSPECTIONS & CONSULTING Inc. Home inspections Housing court services Building assessments Scopes of Work Code compliance Project consulting EXECUTIVE SUMMARY Markus Keller 773/ Illinois License # The subject property is a vintage, frame single family home. At first glance the building appears to be in reasonable condition. However, there are numerous serious problems that should be addressed. This property isn t necessarily in habitable condition as is. Roof shingles are rotted beyond further reasonable use at this point. Immediate replacement is necessary. Signs of multiple roof leaks are evident throughout 2 nd floor ceilings and walls. Water damage from roof leaks is visible in the front bedroom ceiling, at both closets, the middle bedroom and wall areas. Leakage at this point appears to be seepage more than all out pouring in of rain. Based on conditions, leakage is likely to get worse in the near future. The house also appears to be taking in water at the foundation walls. This is not unexpected based on exterior conditions. Signs of water stains, flaking mortar & paint and mold growth are visible at multiple locations. Water intrusion clearly has been an issue in this basement in the past. Someone installed a French drain type ground water drainage system with a sump pump in recent years. These systems are not cheap to install. It is doubtful someone would install a French drain without one being very needed. The drain system appears to be keeping water from flooding the basement floor. Nonetheless water appears to still be leaking through the foundation walls. Over time this continued water seepage through the walls will have structural consequences. The legitimate remedy for this condition is to excavate and properly seal the exterior side of the walls. The house also appears to have sewer problems. The concrete floor area around the bottom of the stairs is cracked, heaved up and sounds very hollow when walked on. This condition is typical of broken sewer tile. The main sewer stack and a floor drain are only a few feet away. Sewer repairs tend to be very expensive. A camera should be run through the sewer line to determine the extent of damage. I suggest you do this prior to closing to get a better idea of repair requirements and associated costs. This house has active knob & tube electrical wiring. Some insurance providers will not provide homeowners coverage with this type of wiring in place. I urge you to check with your carrier immediately regarding coverage limitations.
5 EXECUTIVE SUMMARY continued 5 The existing driveway is deteriorated beyond reasonable further use and sits ~ 5 above the bottom of basement windows. As long as the driveway sits this high basement water intrusion is almost guaranteed. The ground would likely need to be excavated at least 12 + during a new driveway installation. The catch basin will also have to be dealt with. This will be a very expensive project. Joist conditions for the 1 st floor are also somewhat poor. At least one joist is broken in half; numerous joists are rotted at their ends; and rot & water damage are visible at multiple locations at joists and posts. Screw type steel support posts and wood members have been installed to shore up the defective joists. Additional proper repairs are needed. Due to ceiling height and various construction concerns, the basement should be considered a utility and storage space. Turning this into a family type room does not appear feasible. The rear basement egress retaining walls are also in poor condition. The north wall is still fairly vertical at this point. The south wall is clearly leaning inward; blocks have shifted at multiple locations; and one section is leaning in 1.25 past the rest of the wall. Typically these retaining walls will continue to lean in until they collapse. Based on the wall lean and soil expansion under the rear porch enclosure, there may also be soil or water issues that need repair. The 1 st and 2 nd floor rooms are in generally good condition. Walls and ceilings have age typical plaster cracks; original hardwood floors are refinished and clean; and components are basically intact. Various repairs are needed on walls and ceilings. Age typical wood separation is visible at the stairs to the 2 nd floor. Repairs should be performed by a qualified carpenter. Windows throughout the house are a combination of newer and older. Original windows are in fair to poor condition. Plumbing and electrical conditions throughout the house range from good to poor. Numerous repairs are needed as outlined in report sections. Water to the bathrooms was turned off at the time of inspection. Fixtures could not be checked for leaks. The 2 nd floor bathroom clearly has leak issues. The HVAC system is older and poorly installed. Newer duct runs to 2 nd floor rooms appear to be providing insufficient air flow. The 2 nd floor rear porch enclosure room has no heat supply at all. The 2 nd floor front bedroom heat duct blows into an open joist cavity. A high percentage of air volume is being lost inside the joist cavity instead of actually heating the room. Utility bills with the current system may be very high. Exterior conditions are older and fair overall. Wood trims are rotted and siding is in fair condition. Extensive repair and replacement work will be needed at all exterior wood components. This house is in need of extensive rehab work throughout to provide needed safety repairs and upgrades. Overall conditions aren t very good. I suggest you take the costs and timelines into serious consideration. This house will essentially be an ongoing, long term rehab project. Immediate, comfortable occupancy may not be entirely feasible depending on your requirements.
6 DEFECT SUMMARY 6 Defect: The north driveway sits ~ 5 above the bottom of the basement windows. The driveway should sit below the bottom of any windows and the top of the foundation. The current condition virtually guarantees the basement will take in water. Recommend: Due to the erosion of the driveway, replacement is needed regardless of elevation. Replacing the driveway will be very expensive for several reasons. At least 12 + of asphalt and soil need to be excavated in order to bring the driveway to proper grade. Proper drainage, soil bed preparation, slope and material usage should all be taken into consideration. Additional costs will be incurred to deal with either lowering or de-commissioning the catch basin. This will not be an easy project. I suggest you consult with a qualified architect when considering driveway replacement options. Most villages also have specific drainage criteria that must be met for permit approval. Consult your municipality. Defect: Soil levels at the east, west and south elevations somewhat high, essentially at window level. This grade height tends to contribute to water intrusion Recommend: Consider re-sloping grade away from house Defect: Broken joist to east of chimney, rotted joist ends and poor connections at multiple joists west side of chimney, twisted and rotted joist next to furnace, rear side; multiple rot and water damaged joist areas throughout; rotted posts ends and beam Recommend: Proper replacement of all defective members by qualified carpenter Defect: Multiple cracks in basement concrete floor. Some cracks appear age typical; some appear to be due to potential sewer problems Recommend: repair as necessary Defect Concern: Due to the amount of potential water leakage from the 2 nd floor bathroom, 1 st floor ceiling joists may need repair Recommend: remove ceiling during bathroom repair, assess joists and repair as needed Defect: cracks in basement floor Recommend: repair as desired Defect: rotted and poor framing at grade for rear porch enclosure Recommend: full assessment and repair by qualified carpenter Defect: extensive signs of water exposure and damage at joists and subflooring along basement ceiling under kitchen Recommend: assessment and repair by qualified carpenter
7 DEFECT SUMMARY continued 7 Defect: steel screw type lolly columns with regular threaded bolt in spacer hole; These columns are typically only rated for temporary use. The threaded bolt in the spacer hole is not an approved support Recommend: Rating assessment by qualified professional, replacement of unapproved materials, proper installation Defect: rotted jamb at floor, basement rear door Recommend: replace framing and door as desired Defect: rear exterior wood basement hatchway doors and trim rotted Recommend: repair or replace as desired Defect: rotted window frames and trims, deteriorated wood putty at older wood windows Recommend: repair or replace windows as desired Defect: eroded caulk joints at siding seams, this condition tends to allow water to saturate the siding fiberboard backing and create moisture problems along the wall Recommend: clean joints and re-caulk as needed, consider installing new siding Defect: rotted wood framing at front and rear entry stairs and decks Recommend: porches can be repaired but replacement will be needed at some point in the not too distant future, replacement would be a better option Defect: 2 wasps nests top of house Recommend: remediation by qualified professional Defect: roof shingles deteriorated beyond further reasonable use, roof leaks Recommend: full replacement Defect: loose and rotted posts at garage supports, rotting eaves at garage, disconnected downspout, rotted framing at ornamental roof structure Recommend: repair or replace as desired, wood posts should be elevated up off the ground with approved brackets Defect: south wall of rear porch enclosure severely rotted out, structural damage, water seeping into wall Recommend: remove all rotted materials and rebuild wall; This could be a very expensive repair job depending on how long the wall has been taking in water. There could be framing damage inside the walls that may need extensive or full replacement. Based on what is visible, full wall replacement may be likely. Defect: no caps or rain hats at chimney flue pipes Recommend: install proper caps, verify flue pipe to chimney joints water tight
8 DEFECT SUMMARY continued 8 Defect: Older furnace, signs of rust at heat exchanger, gas valve has been modified and jumped for standing pilot, disconnected spark ignition wiring laying in furnace, motor wiring does not appear original Recommend: at minimum assessment and repair by qualified HVAC technician, furnace replacement would be a better option Defect: open ended duct runs without proper termination, un-insulated ducts in unconditioned space under rear porch enclosure and attic, ducts insufficiently supported Recommend: Proper duct and boot installations by qualified HVAC installer Defect: no heat ducts to 2 nd floor rear porch enclosure room Recommend: install sufficient ducts to heat space properly Defect: improper furnace filter installation, inside of furnace dirty, ducts and return chases all very dirty Recommend: install proper filter, clean and check unit and ducts Defect: AC condensate PVC drain pipe broken, no air gap, trap or secondary drain installed at AC drain Recommend: install proper drain assembly for AC condensate drain as per Manufacturer specifications Defect: open electrical boxes, open wiring and wiring not properly terminated at various locations Recommend: Full repair by licensed electrician Defect: Receptacles tested as improper wiring: left outlet behind fridge, 2 nd floor middle bedroom left wall outlet hot/neutral reversed; 2 nd floor rear bedroom NE outlet open ground Recommend: Defect: many receptacles throughout house have layers of paint on them Recommend: Full replacement of any painted outlets by a licensed electrician Defect: no cover on dishwasher electrical connection box Recommend: install manufacturer supplied cover on box, assess and secure wiring Defect: No covers on two receptacles behind refrigerator Recommend: install covers Defect: middle bedroom, window wall receptacle, no power; rear bedroom ceiling fan did not function; Recommend: Full repair by licensed electrician
9 DEFECT SUMMARY continued 9 Defect: electrical service in partial contact with roof, reachable from window, installation may not be compliant or necessarily safe Recommend: consider assessment by licensed electrician Defect: no dielectric unions between old galvanized pipe and newer copper pipe; this will eventually lead to leaks Recommend: install proper dielectric unions at all joints between dissimilar materials by qualified plumber Defect: rusted galvanized pipe and fittings at multiple locations Recommend: consider removing all old pipe and replacing with new copper Defect: no gas shut-off valve behind stove to turn off gas Recommend: install approved gas cock within reach of stove Defect: Plaster cracks along walls and ceilings throughout house Recommend: repair as desired Defect: water damaged plaster at walls and ceilings in various areas of 2 nd floor from roof leaks, in closets front wall of front bedroom, etc Recommend: repair as desired after roof replacement Defect: window lock handle broken, right window of left window unit, rear porch enclosure, 1 st floor; window locks non-functional at multiple old windows, locks broken, wood rotted Recommend: replace hardware as desired Defect: poor insulation at rear porch enclosure to 1 st floor Recommend: install proper insulation Defect: very poor and insufficient insulation in attic Recommend: consider fully upgrading insulation type and levels to provide better insulation R value, increase comfort and reduce heating bills Defect: attic access hatch not insulated, poor location over toilet, no light or dedicated floor area inside of access hole Recommend: consider moving access hatch to another location such as the hallway, insulate cover to same R value as attic space, provide approved landing and lighting inside of attic access Defect: Water turned off to 1 st floor powder room and 2 nd floor bathroom, unable to test fixtures Recommend: Test fixtures and pipes prior to closing to assess condition
10 DEFECT SUMMARY continued 10 Defect: 2 nd floor bathroom tiles cemented onto plywood, tiles and grout popping up and loose along all of floor Recommend: full removal and proper replacement with new materials Concern: refrigerator not plugged in during inspection, not functional Recommend: verify that refrigerator actually works Defect: old electric exhaust fan assembly in corner of attic Recommend: removal as desired Defect: Wasps appear to be getting into the attic Recommend: consider proper remediation of 2 nests by qualified professional Defect: 2 nd floor toilet sinking into floor, tiles popping up around toilet, extensive signs of water leaks on 1 st floor ceiling under bathroom Recommend: open floor and ceiling as needed to assess and repair plumbing leaks, provide all repairs for daily use of bathroom HAZARDOUS CONDITIONS: Any items listed as hazardous should be carefully considered. Hazardous conditions can adversely affect the health and safety of building occupants. Such items should be evaluated by a licensed professional in that field and repaired or replaced immediately. Hazardous Defect: rear basement egress retaining walls, leaning in, blocks shifted and out of alignment, mortar erosion and block damage; Leaning of the south wall will most likely continue over time, full collapse at some point is a real possibility Recommend: consider removal and replacement Hazardous Defect: ungrounded two prong receptacles in 1 st floor living and dining room areas; floor receptacles without approved covers Recommend: replacement of 2 prong receptacles and installation of approved covers at any floor outlets by licensed electrician Hazardous Defect: improper flue pipe set-up for water tank, carbon monoxide can leak out of duct taped boot assembly, no 12 rise from hood prior to elbow Recommend: install proper flue pipe assembly by qualified plumber Hazardous Defect: active original knob & tube wiring in attic along floor; wiring mostly covered with insulation and unprotected, brittle insulation on wiring Recommend: Full removal and proper re-wiring by a licensed electrician; Some mortgage and insurance providers will not provide services or coverage with active knob & tube wiring present. I strongly urge you to check with your providers for coverage availability
11 11 HAZARDOUS CONDITIONS continued: Hazardous Defect: no handrail along stairs to basement Recommend: install approved handrail assembly along stairs Hazardous Defect: The fireplace should NOT be considered safe to use. The installed assembly and flue pipe are a retrofit installation and are unlikely to meet any safety standards. Dangerous carbon monoxide gases, flames and sparks are very possible. Recommend: Removal gas log assembly and gas supply pipe. DO NOT use this fireplace as is. If you wish to make the fireplace active, I suggest you hire a qualified fireplace installer to install an approved unit with a proper flue assembly. Hazardous Defect: 2 nd floor rear porch enclosure room ceiling VERY bouncy with excessive up/down movement, collapse hazard. This could be an age typical problem since these types of ceilings often times were not very well structured. However, the amount of bounce is more than typical, there may framing defects or joist breaks. Recommend: Full assessment and stabilization by qualified carpenter Hazardous Defect: no functional smoke detector located Recommend: install smoke detectors in approved locations Hazardous Defect: front left burner of stove would not light, no anti-tip bracket at stove, no gas shut-off valve, stove damaged Recommend: install required anti-tip bracket per manufacturer specifications, repair stove as needed, install shut-off, consider replacement If you have any questions about the general condition of your building in the future, please give me a call. We would be happy to assist you. We hope you find our service valuable and will recommend AIC to your friends and associates. Sincerely, Markus Keller, Inspector AIC We can provide additional copies of this report in various formats upon request.
12 12 BUILDING CONSTRUCTION Building Address: Bedrooms: 3 # of Units: Single family Bathrooms: 2 Approximate age: +/- 85 years Enclosed porch: YES Approx. building size: 25x43 Approximate sq. ft. each floor: 943 Construction Type: Frame 4B Style: Victorian Occupancy Class: A1 Stories: 2 Basement: YES Basement height: 6 + Attic: Utility only Attic height: NA Crawl space: Under rear porch encl. Approx. lot size: 40x150 Environmental Considerations Mold like substances (MLS): YES Locations: basement Lead-based paint: NA Indicators: Above grade Oil tanks: NO Asbestos type wrap on heating pipes or 9x9 tile: NO
13 SOIL & VEGETATION CONDITIONS / GRADING 13 The intent of this section is to note to what extent if any, soil levels or vegetation conditions are causing damage to exterior wall surfaces. This inspection report does not include the testing of soils for composition, hazards or fertility. Visible signs of potential hazards will be noted in this report. Specific soil concerns should be addressed by a licensed professional in that field. Ground level at each OK Too Very Rot and Comments Elevation walls Y/N High Low decay North X X At least 5 too high South X X X Ground at window level East X X X West X X Exterior trims rotting Y from plant contact? Trees in contact with N roof? Tree roots heaving up sidewalks? N Driveway above bottom of window and top of foundation Eroded driveway and catch basin
14 14 Soil comments & conditions Defect: The north driveway sits ~ 5 above the bottom of the basement windows. The driveway should sit below the bottom of any windows and the top of the foundation. The current condition virtually guarantees the basement will take in water. Recommend: Due to the erosion of the driveway, replacement is needed regardless of elevation. Replacing the driveway will be very expensive for several reasons. At least 12 + of asphalt and soil need to be excavated in order to bring the driveway to proper grade. Proper drainage, soil bed preparation, slope and material usage should all be taken into consideration. Additional costs will be incurred to deal with either lowering or de-commissioning the catch basin. This will not be an easy project. I suggest you consult with a qualified architect when considering driveway replacement options. Most villages also have specific drainage criteria that must be met for permit approval. Consult your municipality. Defect: Soil levels at the east, west and south elevations somewhat high, essentially at window level. This grade height tends to contribute to water intrusion Recommend: Consider re-sloping grade away from house High driveway pad grade And rotted door High driveway and rotted wood siding
15 BUILDING FOUNDATION 15 Foundation type: Is foundation exposed at exterior? Is foundation exposed at interior? Concrete block and masonry NO YES Foundation along Age typical Defective Comments grade - exterior conditions conditions North X Water intrusion visible along all elevations South X East X West X Visible cracks X Visible separation X Visible holes X Wall and floor areas throughout the basement showed signs of cracks and water intrusion during the inspection. Flaking paint and mortar were visible at multiple wall locations. The installation of the French drain appears to have stopped water from flooding the basement floor. However, water appears to still be seeping through the foundation wall. Extended seepage can deteriorate the foundation walls and cause structural damage. This condition should not be taken lightly. Anything short of excavating the exterior and properly sealing the walls is only a temporary band-aid fix and will not stop foundation wall deterioration. Northeast corner water intrusion cracked, heaved floor at bottom of basement stairs. Likely due to sewer tile failure
16 16 Vegetation Notes Plants & Bushes should be planted 18 away from walls, regardless of construction type to reduce water transfer onto the walls during rain or watering and to reduce water levels at the foundation wall. Areas that slope towards building should be built up with appropriate soil to slope away from the building. Foundation Notes Every crack or opening in the foundation wall (or floor) is a potential source for moisture entry. We strongly recommend that THE CLIENT MAKE AN INQUIRY WITH THE CURRENT OWNER AS TO WHETHER THERE HAS EVER BEEN ANY MOISTURE, SEEPAGE OR FLOODING INTO THE HOUSE OR FOUNDATION. In Chicago, odds are, every basement will leak at some point. The biggest enemy of a foundation is water. Excess water from greenery, sprinklers or downspouts should be avoided. You should check such conditions around perimeter walls periodically. Indentations in soil along walls can be an indication of developing problems. Ideally 8 of the foundation wall should be exposed above the soil line Only the readily visible portions of the foundation and structure were observed. Foundation surfaces hidden behind finishes cannot be observed by the inspector. Defects may be present at hidden foundation areas that could allow water infiltration or may have been caused by structural movement. Some foundation cracking is typical of settlement and/or shrinkage and does not usually indicate a structural deficiency. It should be understood that in the Chicago-land area every basement will likely leak at some point. Often times this is due to conditions beyond the control of the existing structure. Structural Notes Structural defects may be hidden behind dense foliage, vines, snow, stored items, debris or finishes and can not be included with this inspection.
17 STRUCTURAL COMPONENTS Joists and Rafters 17 Structural components Size Type Functional condition In need of repair Comments Basement Concrete X X Numerous cracks 1 st floor 2x8 Wood X X Cracks and rot 2 nd floor 2x6 Wood X X Covered Rafters 2x4 Wood X Age typical condition Main beam 6x6 Wood X X Age typical splitting Support posts 6x6 X X Rotted at floor level, age typical splitting Steel lintels NA Rotted, twisted joist Rear retaining wall severely crack, eroded Separated and leaning in
18 18 Broken joist, left of wash machine extensive water stains/damage At basement sub-floor and joists Structural and Foundation comments & defective conditions: Defect: Broken joist to east of chimney, rotted joist ends and poor connections at multiple joists west side of chimney, twisted and rotted joist next to furnace, rear side; multiple rot and water damaged joist areas throughout; rotted posts ends and beam Recommend: Proper replacement of all defective members by qualified carpenter Defect: Multiple cracks in basement concrete floor. Some cracks appear age typical; some appear to be due to potential sewer problems Recommend: repair as necessary Defect Concern: Due to the amount of potential water leakage from the 2 nd floor bathroom, 1 st floor ceiling joists may need repair Recommend: remove ceiling during bathroom repair, assess joists and repair as needed Hazardous Defect: rear basement egress retaining walls, leaning in, blocks shifted and out of alignment, mortar erosion and block damage; Leaning of the south wall will most likely continue over time, full collapse at some point is a real possibility Recommend: consider removal and replacement
19 BASEMENT See Structural section for other details 19 BASEMENT Y/OK NP Defective In Comments need of Repair Most recent use Utility & storage EXTERIOR WALLS Primary wall surface X X Concrete block Areas of water Y X X All elevations, signs of seepage intrusion BASEMENT FLOOR Primary floor surface X Concrete Signs of heaving or open cracks Y X X Significant heaving around bottom of stairs, age typical minor cracking throughout, no large/open cracks Y Floor drains present Floor drains wet/dry W X Signs of biologic Y X Drywall wall adjacent to hazard (mold) electrical room BASEMENT CEILING Type X X Open wood joists Overall condition X X Fair, age typical BASEMENT WINDOWS AND VENTILATION Type X X Glass block Broken windows N LAUNDRY ROOM Washer installed Y Type of supply hose X Typical Manufacturer supplied rubber hoses Drain hook-up X Drain hose to utility sink Signs of leaks N Dryer installed Y X Type of vent line Corrugated metal foil Type of gas line X ½ black pipe UTILITY ROOMS Y Semi open space STORAGE ROOMS Y 1
20 20 French drain along basement Foundation wall Signs of water intrusion, basement wall flaking paint and mortar along basement wall, typical of water intrusion more signs of water intrusion Basement comments & defective conditions: Defect: cracks in basement floor Recommend: repair as desired Defect: rotted and poor framing at grade for rear porch enclosure Recommend: full assessment and repair by qualified carpenter Defect: extensive signs of water exposure and damage at joists and subflooring along basement ceiling under kitchen Recommend: assessment and repair by qualified carpenter Defect: steel screw type lolly columns with regular threaded bolt in spacer hole; These columns are typically only rated for temporary use. The threaded bolt in the spacer hole is not an approved support Recommend: Rating assessment by qualified professional, replacement of unapproved materials, proper installation Defect: rotted jamb at floor, basement rear door Recommend: replace framing and door as desired
21 EXTERIOR CONDITIONS 21 Primary exterior wall covering: Older aluminum siding Secondary exterior wall covering: Wood trims Areas of damage: YES see defect list Stairs Front- Type: Wood Guardrails: Wood Overall condition: Fair, rotted Rear: Type: Wood Guardrails: Wood Overall condition: Fair, rotted Service walks Front- Type: Pavers Pitch of service walks- away from house Overall condition: good Rear- Type: asphalt Pitch of service walks- towards house & away from house Overall condition: Fair Side- Type: Asphalt driveway Pitch of service walks- towards house Overall condition: eroded beyond further reasonable use *Note- If service walks are pitched towards the house, this may contribute to foundation wall water exposure. Check periodically to ensure that the service walk to wall joint is properly sealed. deteriorated siding condition poor caulk at joints
22 EXTERIOR CONDITIONS continued 22 Doors Front- Type: Wood & glass Overall condition: Good Deadbolt: YES Weatherstripping: No Locks engaging in jamb: YES Peephole: NA Rear- Type: Wood Overall condition: Original Deadbolt: No Weatherstripping: No Locks engaging in jamb: NA Peephole: No Exterior Window conditions Type of windows: Approximate age of windows: Insulated Glass: YES & NO Storm windows: Exterior of wood windows capped: Exterior of windows caulked: Broken windows: Vinyl replacement and original wood Newer and original Window locks: YES & NO YES & NO NO YES & NO YES *Note- Newer window types typically do not have storm windows Soffits, Fascia & Eaves Type: Wood Condition: Fair to poor Vented: NA Continuous soffit vent: NO Gutters & Downspouts Gutter Type: Condition: Aluminum Fair, newer * Note Gutters and downspout openings should be cleaned out seasonally. Clogged gutters often times will lead to roof and wall leakage. Downspout type: Condition: Downspouts tied into sewer system: Downspout extensions: Downspouts extended 6 feet: Aluminum and plastic average NO YES & NO NO *Note- downspouts should be extended out from the house 6 as possible without creating a trip hazard in order to keep water away from foundation walls.
23 EXTERIOR CONDITIONS continued 23 Lintels & Stone sills - NA Roof system Type of main roof: Shingles- Condition of roof material: Flashings intact at vents: Signs of roof leaks: Number of Roof layers: Roof penetrations: Skylights: Plumbing stacks: Attic furnace: Flashings At valleys: At eaves: Roof Vents Standard roof vents: Ridge vent: pitched roof shingles standard asphalt type deteriorated beyond further use Poor condition Multiple at 2 nd floor ceilings undetermined None not visible NA NA undetermined YES NO *Note older homes typically do not have ridge vents Chimneys Type: Brick Number of flues: one Condition: Overall good Chimney Cap: NO Critter guard: NO Rain hat: NO Signs of roof leaks? YES Are trees in contact with roof? NO
24 24 Deteriorated, curling roof shingles, front and rear roof areas Rotted framing for porch Rotted wood post base in contact with ground One of two Wasp nests rotted out south wall
25 25 Exterior comments & defective conditions: Defect: rear exterior wood basement hatchway doors and trim rotted Recommend: repair or replace as desired Defect: rotted window frames and trims, deteriorated wood putty at older wood windows Recommend: repair or replace windows as desired Defect: eroded caulk joints at siding seams, this condition tends to allow water to saturate the siding fiberboard backing and create moisture problems along the wall Recommend: clean joints and re-caulk as needed, consider installing new siding Defect: rotted wood framing at front and rear entry stairs and decks Recommend: porches can be repaired but replacement will be needed at some point in the not too distant future, replacement would be a better option Defect: 2 wasps nests top of house Recommend: remediation by qualified professional Defect: roof shingles deteriorated beyond further reasonable use, roof leaks Recommend: full replacement Defect: loose and rotted posts at garage supports, rotting eaves at garage, disconnected downspout, rotted framing at ornamental roof structure Recommend: repair or replace as desired, wood posts should be elevated up off the ground with approved brackets Defect: south wall of rear porch enclosure severely rotted out, structural damage, water seeping into wall Recommend: remove all rotted materials and rebuild wall; This could be a very expensive repair job depending on how long the wall has been taking in water. There could be framing damage inside the walls that may need extensive or full replacement. Based on what is visible, full wall replacement may be likely. Defect: no caps or rain hats at chimney flue pipes Recommend: install proper caps, verify flue pipe to chimney joints water tight
26 26 Roof Notes This inspection is made on the basis of what is visible and accessible on the day of the inspection and is not a warranty of the roof system or how long it will be watertight in the future. Exterior Notes Downspouts should be extended away from walls at ground level for 6. If relocating downspouts, do so without creating a trip hazard along service walks or used pathways Flashings at chimneys should be checked periodically that joints are closed and intact. Chimneys are a prime source of leak problems. Additional defects may be found when repairs are made to items listed in this report or when remodeling is done to the exterior. We cannot be held responsible for any hidden defects found after the inspection.
27 HVAC Heating 27 FURNACE # 1 BASEMENT Heating Y/Ok NP Functional In Comments equipment Condition need of Repair Furnace #1 AFUE % Heat working Y X during inspection? Color of Flames X X Blue Brand & Model # Lennox G11QE3-137V-4 Unit BTU out 137,000K Accessories Air cleaner type X Filter Air cleaner size 16x25x1 EAC functional X None Media condition Dirty HUM brand/type X None HUM functional Signs of leaks HUM drain to Thermostat type X Programmable Components Condition of ducts Poor, open ends, rusty, dirty Gas supply type ½ black pipe Main gas shut-off Front of building behind bushes 80+ AFUE Unit Overall condition of unit & approx. age Older, deteriorated, consider full replacement Size of flue pipe X 5 Condition of flue X Fair to good pipe Flue pipe joints X X Screwed not taped screwed or taped? Gas connection type X Old gas shut-off valve on wrong side of union Drip leg at unit Y X Gas shut-off accessible? X X
28 28 Attic duct runs, main chase and cover not insulated Un-insulated and not properly supported duct runs in crawlspace open ended duct run inside of joist cavity, substantial heat loss rusted furnace, jumped wiring
29 29 Heating comments & defective conditions Defect: Older furnace, signs of rust at heat exchanger, gas valve has been modified and jumped for standing pilot, disconnected spark ignition wiring laying in furnace, motor wiring does not appear original Recommend: at minimum assessment and repair by qualified HVAC technician, furnace replacement would be a better option Defect: open ended duct runs without proper termination, un-insulated ducts in unconditioned space under rear porch enclosure and attic, ducts insufficiently supported Recommend: Proper duct and boot installations by qualified HVAC installer Defect: no heat ducts to 2 nd floor rear porch enclosure room Recommend: install sufficient ducts to heat space properly Defect: improper furnace filter installation, inside of furnace dirty, ducts and return chases all very dirty Recommend: install proper filter, clean and check unit and ducts *Note current furnace and duct conditions will cause much higher utility costs than would be seen if the system were properly installed. *Note some municipalities restrict the use of and type of flexible ductwork Furnace notes Furnace filters should be changed regularly, at a minimum once at the end of summer and once at the end of winter. If you have pets consider changing the filter monthly. Proper operation of all units should be verified prior to closing. A conclusive evaluation of a furnace heat exchanger or a boiler combustion chamber requires dismantling of the unit, including burner removal, and is, therefore, beyond the scope of this inspection. We do not report on, nor can we be held responsible for, these items.
30 Air Conditioning - central 30 AC equipment Y/Ok NP Functional condition In need of Repair Comments AC #1 AC working during inspection AC was not tested due to low outside air temperature Did space come NA down to set temperature? Brand & Model # Carrier 38CKCO42310 AC size & SEER 3.5 Electrical Disconnect near Y X unit? Liquidtight from Y X disconnect to unit Signs of Electrical N X damage Min. 12 & 30 Y X clearances at all sides as req. Components Is lineset insulated Y Filter / dryer installed A-coil inspected N Condensate drain N Broken pipe on floor line leads to Trap installed on N N None condensate line Secondary drain N None from A-coil installed? Roof drip N None protection for Condenser Window air conditioners None
31 31 AC drain connection AC broken drainpipe AC comments & defective conditions: NOTE- AC will not be operated at temperatures below 65 degrees Defect: AC condensate PVC drain pipe broken, no air gap, trap or secondary drain installed at AC drain Recommend: install proper drain assembly for AC condensate drain as per Manufacturer specifications AC Notes Air conditioning systems cannot be checked at temperatures lower than 62 degrees The larger of the two copper lines leading to the compressor (unit at the exterior) should always be insulated. An un-insulated line can lead to a 2% - 10% reduction in efficiency. Check the drain pipe at the furnace air conditioning coil each season to ensure it is not blocked
32 ELECTRICAL 32 Category Present Y / N Not present Y /N Functional condition In need of repair Comments DISTRIBUTION Service size & type 100 AMP, aluminum wire Service entry Pipe Adequate support Y for service pipe Weather head Y attached Meter housing & Good condition ground rod Service panel Basement, SE corner on wall location & shut-off Panel type & size Eaton, Breakers, 30 position Available slots in Y Y 8 panel? Are breakers Y Y labeled? Arc fault breakers? Y 1 GFCI breakers? N Suff. clearance Y around panel Ground connection Brass connector & # wire to water main GENERAL 220V receptacles None Signs of old, frayed wiring? GFCI in Kitchen Y GFCI in Bathrooms Y Broken switches N Broken receptacles N Broken lights N Bare bulb fixtures N Floor receptacles 2 prong outlets Exterior receptacles Rear of house
33 33 Open electrical box no covers, mis-wired receptacle electrical service in contact with roof live knob & tube wiring Electrical Notes Outlets in kitchens and bathrooms must be GFCI. Depending on the location in a kitchen in proximity to a water source not every single outlet must be GFCI Attempting to do electrical repairs yourself is NOT recommended. Hire an electrician, your life may depend on it. An electrical panel containing paint or other foreign materials on should be replaced
34 Electrical comments & defective conditions: 34 Hazardous Defect: active original knob & tube wiring in attic along floor; wiring mostly covered with insulation and unprotected, brittle insulation on wiring Recommend: Full removal and proper re-wiring by a licensed electrician; Some mortgage and insurance providers will not provide services or coverage with active knob & tube wiring present. I strongly urge you to check with your providers for coverage availability Defect: open electrical boxes, open wiring and wiring not properly terminated at various locations Recommend: Full repair by licensed electrician Defect: Receptacles tested as improper wiring: left outlet behind fridge, 2 nd floor middle bedroom left wall outlet hot/neutral reversed; 2 nd floor rear bedroom NE outlet open ground Recommend: Defect: many receptacles throughout house have layers of paint on them Recommend: Full replacement of any painted outlets by a licensed electrician Defect: no cover on dishwasher electrical connection box Recommend: install manufacturer supplied cover on box, assess and secure wiring Defect: No covers on two receptacles behind refrigerator Recommend: install covers Defect: middle bedroom, window wall receptacle, no power; rear bedroom ceiling fan did not function; Recommend: Full repair by licensed electrician Hazardous Defect: ungrounded two prong receptacles in 1 st floor living and dining room areas; floor receptacles without approved covers Recommend: replacement of 2 prong receptacles and installation of approved covers at any floor outlets by licensed electrician Defect: electrical service in partial contact with roof, reachable from window, installation may not be compliant or necessarily safe Recommend: consider assessment by licensed electrician
35 PLUMBING Water supply Source of domestic water: Water supply entry main: Main interior shut-off: Water supply pipes: Supply lines at fixtures: Water drainage Removal of waste water: Drain & waste lines: 35 Municipal supply basement along north wall under stairs same location combination old Galvanized & copper braided metal hose and tube Municipal sewer combination old Galvanized & new PVC Pits Sump pit: YES check valve at outlet side: YES Pump working: YES Vent installed: NO Ejector pit: NO Pit type: Pump working: Vent installed: Check valve at outlet side: Floor drains YES near water tank Venting plumbing Vent stack type at roof: undetermined Sufficient flashing at vent stacks on roof: undetermined NOTE: Raining during inspection, not safe to access roof Water tank(s) Water tank size: 40 Gallon Bradford White Shutoffs on Water tank: Cold inlet: YES Hot outlet: NO Condition of flue piping at hot water tank, type & size: 4 metal flue pipe Temperature & pressure relief valve at hot water tank: YES Discharge pipe at hot water tank with 6 of floor: YES Gas connection type: ½ black pipe Drip leg at unit: YES PLUMBING accessories Laundry sink: PVC utility type Wash machine: YES Gas Dryer: YES Exhaust type at gas dryer: metal foil
36 36 improper and hazardous flue pipe set-up for water tank rusted galvanized pipe and fittings Plumbing comments & defective conditions: Hazardous Defect: improper flue pipe set-up for water tank, carbon monoxide can leak out of duct taped boot assembly, no 12 rise from hood prior to elbow Recommend: install proper flue pipe assembly by qualified plumber Defect: no dielectric unions between old galvanized pipe and newer copper pipe; this will eventually lead to leaks Recommend: install proper dielectric unions at all joints between dissimilar materials by qualified plumber Defect: rusted galvanized pipe and fittings at multiple locations Recommend: consider removing all old pipe and replacing with new copper Defect: no gas shut-off valve behind stove to turn off gas Recommend: install approved gas cock within reach of stove
37 37 Plumbing Notes Water leaks may not appear during the inspection if the home is vacant due to lack of normal usage, but may appear only after repeated usage, and we cannot be held responsible for these. Supply and drainage piping is observed in exposed areas only. The condition of hidden piping within walls cannot be determined as a part of this inspection. The condition of underground drainage and waste piping cannot be determined by this inspection. We strongly recommend that THE CLIENT MAKE AN INQUIRY WITH THE CURRENT OWNER AS TO THE CONDITION OF UNDERGROUND DRAINAGE AND WASTE PIPING AND IF THERE IS ANY HISTORY OF SEWAGE BACK-UPS INTO THE HOUSE. There should not be a shut-off valve on the hot water outlet side of the hot water tank If the temperature relief valve (TPR) on the hot water tank releases and discharges hot water there may be a serious problem. Turn off the gas to the unit, for safety and call a qualified plumber to evaluate the condition. The pipe from the TPR should extend down to within 6 of the floor to reduce a scalding hazard If a faucet seems to be running slower than usual, try unscrewing the aerator at the end of the spout and cleaning the filter inside. That filter tends to clog over time, especially with older piping. If you are interested about the quality & purity of your Tap water, testing kits are available. Many are very reliable and test for numerous contaminants and bacteria ($15-$20) Environmental Protection Agency s Safe Drinking Water Hotline
38 KITCHEN 38 Overall kitchen style: Damaged areas in kitchen: Traditional YES APPLIANCES Refrigerator: YES Brand: undetermined Age: mid-age Type of supply line: None Leaks: Dishwasher: YES Brand: Bosch Age: newer Type of supply line: copper Dishwasher leak during cycle: NO Stove: YES Brand: Amana Age: newer Gas hook-up: SS hose Anti-tip bracket in place? NO Garbage disposal: YES Brand: Kitchenaid Electric supply armored cable to switch box Attached Microwave: NO Exterior venting - Pipe: NA *Note- Manufacturer s of combination microwave / kitchen exhaust units require 6 rigid metal pipe for units being vented to the exterior KITCHEN FAUCETS Faucet style & condition: Chrome, 2 handle with sprayer Hot & cold water on proper sides at faucets YES Type of supply line: copper tubing Signs of Leaks at supply: NO Signs of leaks at drain line: NO Overall cabinetry conditions- Good Overall countertop conditions- Fair PANTRY NO no cover dishwasher connection No gas valve or anti-tip bracket at stove
39 BATHROOM #1 MASTERBATH 39 Location: 2 nd floor hallway Style & condition: average Room Walls: Drywall Bath & Shower walls: Tile Floor cover: newer ceramic tile Bathroom #1 Component or Fixture Toilet Capacity / Flush Caulked to Floor? Signs of Leaks? Floor around toilet Y/N OK Working condition X Defective Bidet N NA Pedestal Sink N Vanity Signs of Leaks? Supply lines- X Bathtub X Signs of leaks? Caulk joints intact Shower X Yes Light in shower? NO Cover over light? NA Whirlpool N Accessories Medicine Cabinet X Exhaust fan X X X Vented to exterior- Heat lamp N Steam Unit N Components Linen closet N Plumbing Hot & Cold water on proper sides at fixtures? Comments 1.6 gpf No YES Soft and damaged Water off Signs of leaks at 1 st floor ceiling, water off Fair, needs repair Wall head type Attic Water off Supply pipes X Copper Drain pipes X PVC
40 40 BATHROOM ELECTRICAL GFCI outlets: YES Bathroom lighting: Integral outlet in Medicine cabinet: NO Integral light in Medicine cabinet: YES Broken switches NO Broken outlets NO BATHROOM WINDOW BATHROOM DOOR YES Screen in place Type: Wood panel Lockset working YES YES 2 nd floor toilet sinking into floor 2 nd floor bath exhaust fan vented tiles popping up into attic Bathroom notes Check caulk joints at tub/wall and shower/wall intersections regularly. These caulk joints eventually open up. Once they do, water tends to get into the wall and cause damage. Re-caulking periodically can add years of useful use to a tile wall. When caulking a tub or shower the easy thing to do is to spread new caulk right on top of old caulk. However, that isn t the right way to do it and it won t last. It is important to cut out the old caulk first, then apply the new caulk directly to the joint.
41 BATHROOM #2 1/2 BATH 41 Location: 1 st floor hallway Style & condition: vintage Room Walls: drywall and wallpaper Floor cover: newer ceramic tile FIXTURES Bathtub: NO Shower: NO Whirlpool: NO Toilet style & capacity: Signs of leaks: Caulked to floor: Hot & Cold water supplies on proper sides Kohler 1.6 gpf NO NO undetermined ACCESSORIES Exhaust fan NO Heat lamp: NO Steam Unit NO Medicine cabinet: YES BATHROOM ELECTRICAL GFCI outlets: YES Bathroom lighting: 1 wall sconce Integral outlet in Medicine cabinet: NO Integral light in Medicine cabinet: NA Broken switches NO Broken outlets NO Light in shower NA BATHROOM WINDOW NONE 1 st floor powder room
42 INTERIOR CONDITIONS 42 Smoke detectors present: NO none located It should be noted that several smoke detectors have been removed, i.e. master bedroom and front bedroom. This may have been done for various reasons such as, defective units or smoking. Consider replacing these units. Carbon Monoxide detector present: YES behind furnace NOTE: Smoke detectors should be located towards the top of a wall or on the ceiling and located within 4-12 of the wall/ceiling intersection, not in the middle of the wall or ceiling. Carbon monoxide detectors should be mounted on the wall in a central location so it will be heard if it goes off. Signs of water seepage at any locations: YES GENERAL ROOM COUNT: Bedrooms 3 Living room 1 Dining room 1 Sunroom / Office 1 Recreation room 1 Kitchen 1 Bathrooms 1.5 Basement rooms Attic rooms Porch enclosures Mostly open, 1 utility room, 1 electrical room NONE YES 1 st and 2 nd floor
43 INTERIOR FINISH CONDITIONS: 43 WALL components - Primary finish: Plaster and lath Secondary finishes: Drywall Damaged areas: Yes, see defects CEILING components - Primary finish: Secondary finishes: Damaged areas: FLOORS components - Primary finish: Secondary finishes: Other surfaces: Plaster and lath Drywall Yes, see defects Original hardwood Tile Paint DOORS conditions - Rooms: Older wood panel Closets: None Lockset types: Original Locksets working: Yes & No CLOSET SHELVING - Newer metal type and wood LIGHTING - Ceiling fans: Yes Wall sconces: Yes Track lighting: No Recessed cans: No Surface mount fixtures: Yes Dimmers: No ADDITIONAL AMENITIES - None
44 FIREPLACE Location: Type of fireplace Chimney type Damper installed Damper operational Flue condition 1 st floor living room Brick with manufactured gas log firing unit ~ 3 metal pipe NO NA No discernable draft noted 44 Living room fireplace Exterior fireplace flue pipe Inside of fireplace and flue pipe Fireplace Notes: manufactured gas log unit Do not turn on a whole house fan when a fireplace is running. If Fireplaces or Solid Fuel Burning Stoves were present, only visible and readily accessible portions of the fireplaces or stoves have been reviewed. Flue defects may exist that can only be discovered through a Level 2 chimney inspection performed by a qualified chimney sweep. Manually lit gas fireplaces are not operated as a part of this inspection.
45 45 Damaged plaster from water leaks 2 nd floor front closet No handrail at stairs to basement wall and ceiling roof leak damage 1 st floor ceiling, water damage
46 Interior comments & defective conditions: 46 Hazardous Defect: no handrail along stairs to basement Recommend: install approved handrail assembly along stairs Hazardous Defect: The fireplace should NOT be considered safe to use. The installed assembly and flue pipe are a retrofit installation and are unlikely to meet any safety standards. Dangerous carbon monoxide gases, flames and sparks are very possible. Recommend: Removal gas log assembly and gas supply pipe. DO NOT use this fireplace as is. If you wish to make the fireplace active, I suggest you hire a qualified fireplace installer to install an approved unit with a proper flue assembly. Defect: Plaster cracks along walls and ceilings throughout house Recommend: repair as desired Defect: water damaged plaster at walls and ceilings in various areas of 2 nd floor from roof leaks, in closets front wall of front bedroom, etc Recommend: repair as desired after roof replacement Hazardous Defect: 2 nd floor rear porch enclosure room ceiling VERY bouncy with excessive up/down movement, collapse hazard. This could be an age typical problem since these types of ceilings often times were not very well structured. However, the amount of bounce is more than typical, there may framing defects or joist breaks. Recommend: Full assessment and stabilization by qualified carpenter Defect: window lock handle broken, right window of left window unit, rear porch enclosure, 1 st floor; window locks non-functional at multiple old windows, locks broken, wood rotted Recommend: replace hardware as desired Defect: poor insulation at rear porch enclosure to 1 st floor Recommend: install proper insulation Hazardous Defect: no functional smoke detector located Recommend: install smoke detectors in approved locations Defect: very poor and insufficient insulation in attic Recommend: consider fully upgrading insulation type and levels to provide better insulation R value, increase comfort and reduce heating bills Defect: attic access hatch not insulated, poor location over toilet, no light or dedicated floor area inside of access hole Recommend: consider moving access hatch to another location such as the hallway, insulate cover to same R value as attic space, provide approved landing and lighting inside of attic access
47 47 Kitchen and Bathroom comments & defective conditions: Defect: Water turned off to 1 st floor powder room and 2 nd floor bathroom, unable to test fixtures Recommend: Test fixtures and pipes prior to closing to assess condition Defect: 2 nd floor toilet sinking into floor, tiles popping up around toilet, extensive signs of water leaks on 1 st floor ceiling under bathroom Recommend: open floor and ceiling as needed to assess and repair plumbing leaks, provide all repairs for daily use of bathroom Defect: 2 nd floor bathroom tiles cemented onto plywood, tiles and grout popping up and loose along all of floor Recommend: full removal and proper replacement with new materials Hazardous Defect: front left burner of stove would not light, no anti-tip bracket at stove, no gas shut-off valve, stove damaged Recommend: install required anti-tip bracket per manufacturer specifications, repair stove as needed, install shut-off, consider replacement Concern: refrigerator not plugged in during inspection, not functional Recommend: verify that refrigerator actually works NOTE All older homes have maintenance and wear issues that require more or less money to repair or replace. Many of these items do not have to be a deterrent to purchasing a home. Some significant problems should lead you to carefully assess the purchase. No building is perfect. The small things can always be changed or repaired at some point. The bigger issues are important. Are the cost factors too great to make the purchase viable? In the end, the most important question is, Do you want to make this property your home?
48 ATTIC 48 Stairs to attic: NONE Signs of water leaks at rafters / roof: YES Signs of water leaks at chimney: NO chimney roof area dry Signs of varmint entry: YES - wasps Signs of wood rot: NO age typical conditions Exterior ventilation visible at eaves: NO Exhaust fan: YES old electric motor fan Attic access: access to attic is over the 2 nd floor bathroom toilet Attic Floor- open joists Insulation Walls- Ceiling- Roof- None visible Old loose fill wool type in attic at 2 nd floor ceilings None Insulation notes Vintage construction Chicago area homes do not typically have exterior wall insulation. Ceiling, rafter or attic insulation also tends to be limited. Older attic insulation is typically compressed or has been moved around to such extent that it is no longer very effective. Wall insulation should only be installed in the cavity depth listed on the package for that material. Compressing (stuffing it in) the fiberglass batts reduces R value. Consider installing as much insulation as possible throughout. Insulation cost will be recovered through lower heating and cooling costs. When insulating attics or rafters, allowing for proper ventilation MUST be taken into account to avoid future problems. Attic comments & defective conditions: Defect: old electric exhaust fan assembly in corner of attic Recommend: removal as desired Defect: Wasps appear to be getting into the attic Recommend: consider proper remediation of 2 nests by qualified professional
49 49 Exposed attic wiring, poor insulation old exhaust fan in attic GARAGE Garage size: 2 car Garage type: frame newer Chimney in garage: NO Garage roof type & condition: HIP, older asphalt shingles Condition of garage walls: 2x4 studs 24 OC, age typical Condition of garage ceiling: open 2x4 rafters 24 OC, age typical Roof vents: NO Electric garage door opener: Undetermined Door functional with interior button switch? Undetermined Did automatic garage door reverse upon resistance during closure: Undetermined NOTE There was No Entry to the garage during the inspection. The garage was locked. BUILDING ACCESSORIES / OUT BUILDINGS * Depending on their type these items may or may not have been assessed. Their presence is nonetheless noted in this report for your convenience. Signs of severe deterioration or hazard are noted for any items as appropriate. NONE
50 APPROVED PLANS and/or DOCUMENTATION onsite during inspection City permit posted NA City stamped blueprints NA Contract documents NA Change orders NA 50 PURPOSE OF INSPECTION Please be advised that this Home inspection by its nature is limited in scope. Depending on construction style, some areas, systems or components of the building may not be accessible or visible during the inspection to allow review. We can reduce your risk of non-compliant conditions in the Home. However, we cannot eliminate it; nor can we assume it. Even the most comprehensive inspection cannot be expected to reveal every condition you may consider significant to the Home s longevity. This inspection report may contain information about discrepancies, generally unacceptable trade practices, or blatant code issues. It is not within the scope of this report to resolve such issues. LIMITATIONS This report is work product and is copyrighted by ACCURATE INSPECTIONS & CONSULTING, Inc. as of the date of this report (-09). Duplication by any means whatsoever, including sharing access to a protected copy, is prohibited without prior written permission and authorization from the company shown above. Duplication of, use of, or reliance on this report in any way for any purpose whatsoever has the effect of agreeing to the terms and conditions as set forth in the Home Inspection Contract for Services, signed by the original client for ///////////, Chicago, IL. Unauthorized duplication of, use of, or reliance on this report has the effect of all parties agreeing to hold harmless, individually, jointly, and/or otherwise, this inspector, the Company, their successors and assigns AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS. This inspection report should not be considered to be a full compliance inspection for your applicable municipal or non-governmental codes or regulations. Your municipality may have additional requirements based on occupancy, ownership or permit application information that is not available to us. This report is not intended to be a warranty or guarantee of the present or future adequacy or performance of the structure, its systems, or their component parts. Such determinations should be made by your Architect or Engineer. This report does not constitute any express or implied warranty of fitness for use regarding the condition of the property, and it should not be relied upon as such. Any opinions expressed regarding adequacy or expected life of the components are general estimates based on available industry information about such components. Wide variations can be expected between such estimates and actual lifespan based on usage. The home inspector is not required to enter any areas or perform any functions that may cause damage to the building or its components or be dangerous or harmful to the health of the inspector or others present. Corrective measures or modifications to the home prior to purchase should be discussed between the Buyer & Seller and their representatives. A follow up inspection to verify compliance of agreed terms can be arranged. END OF REPORT
Self-Home Inspection Checklist
To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional
Total Home Inspection Checklist
Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are
Georgia Home Inspection Services
Cover Page Property Inspection Report My street, Anytown GA, 30000 Inspection prepared for: John Doe Inspection Date: 7/18/2011 Time: 5pm Age: 25+ Size: >1500 Weather: Clear This ranch style home is in
Vision Home Inspection
Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the
Rehab Inspection Report Page 1
Rehab Inspection Report Page 1 Home Address: Construction Style: Number of bedrooms Square footage: Value of offer: Estimated rehab cost: Value of resale: Orientation of house: N S E W Note: orientation
Inspection Tech. (330) 310-6559 http://www.inspectiontech.us [email protected] Inspected By: Aaron Westerburg
Inspection Tech (330) 310-6559 http://www.inspectiontech.us [email protected] Inspected By: Aaron Westerburg Inspection Tech Home Inspection Report Prepared For: Mr. & Mrs. Homebuyer Property
HOME INSPECTION CHECKLIST
CLOSING.COM LEARNING CENTER HOME INSPECTION CHECKLIST CONTENTS Attic 1 Balconies 1 Basement 1 Bathroom 2 Ceiling, Floors and Walls 2 Crawlspace 3 Decks and Porches 3 Doors and Windows 4 Drainage 4 Driveways
www.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois
Accurate Home Inspection of Illinois 815-260-1727 1213 Norley st. Joliet, illinois 60435 [email protected] We Inspect to Protect!!! Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave.,
159 Morningside Avenue, Toronto
159 Morningside Avenue, Toronto Inspection Report February 6, 2013 159 Morningside Avenue, Toronto Inspection Report Overall Condition: This 60±-year-old home was extensively renovated and extended in
Home Inspection Report
4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 [email protected] Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:
CHRIS CURLES and ASSOCIATES INSPECTION SERVICES
CHRIS CURLES and ASSOCIATES INSPECTION SERVICES Inc. Chris Curles, President www.homeinspectionsatlanta.com [email protected] Office: 770-493-0227 Professional Member Of: GAHI # 93006 ASHI # 211725
PROPERTY INSPECTION REPORT
(850) 297-1998 1716 Monticello Dr Tallahassee, Florida 32303 PROPERTY INSPECTION REPORT THIS INSPECTION IS A DETAILED LISTING OF AREAS VISUALLY INSPECTED AT:, Tallahassee FL Client Tallahassee, FL 32304
A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide
A comfortable house is a great source of happiness. - Sydney Smith Home Maintenance Guide HOME GUIDE By conducting regular maintenance checks, you can prevent small inexpensive repairs from becoming more
Inspecton Report. Property Address:
Inspecton Report Provided by: National Home Inspections Inspector: Bob Smith 456 S Main Denver, CO 46312 (645) 423-3242 [email protected] www.nationalhomeservices.com Property Address: 873
CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111
A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 Inspector Name: Tim Knight, ASHI Member 202490 Inspection No: 12121212 Inspection Date: 1/1/2012 Client: Address: John
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist
Inspection Item COMMENTS
APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:
Vari Inspection Services
Cover Page Vari Inspection Services Property Inspection Report Inspection prepared for: Sample Real Estate Agent: None - Date of Inspection: 5/13/2015 Inspector: Tony Vari License # HI8047 23110 STRD 54
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809
Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division
Code Enforcement Inspection Manual City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division LIVING ROOM 304.15 EXTERIOR DOOR(S) Check door(s) and trim for condition,
Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000
Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,
Orlando Home Inspection Services
PLEASE NOTE: Orlando Home Inspection Services Serving Central Florida since 1999 P O Box 915451, Longwood, Florida, 32791-5451 Phone: (321) 228-2493 Fax: (407) 374-8505 Web: http://www.orlando-home-inspections.com
COMPREHENSIVE PROPERTY INSPECTIONS
COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited
#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check
#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check Zoning laws Deed restrictions on home size, foundation style, roof pitch, etc. Suitability (slope, wetland issues, etc.) Accessibility
Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM
Pa g e 1 o f 1 5 All About Homes, LLC Michelle M. Teague Owner 312-371-7414 Phone 773-508-6209 Fax www.michelleinspects.com [email protected] 1725 W. Granville Ave. Chicago, IL 60660 Printed
Home Inspection Report
Report# 21009 Page 1 of 24 Home Inspection Report Property Address: 123 Maple Lane, St. Augustine, FL 32092 Prepared For: Mr. Smith Prepared By: EDGE Inspections www.edgeinspections.com PO Box 601055 Jacksonville,
Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288
Page 1 of 22 Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288 Printed Friday, January 16, 2015 Inspected By: Dale Gibbs Referral Information Joe Agent Client Information:
SWF Home Inspections
Cover Page SWF Home Inspections Property Inspection Report Inspection prepared for: Mr & Mrs Home Buyer Real Estate Agent: My Favorite Agent - Date of Inspection: 7/4/2013 Age of Home: 2004 Size: 1568
Home Management Checklist: Spring
Home Management Checklist: Spring HVAC System Attic Plumbing and Electrical Service air conditioning unit (Ventilation inspected as part of service call). Ensure gutters are discharging water away from
Home Maintenance Checklist
Regular maintenance keeps your home functioning efficiently and safely and helps protect its value. We're happy to offer this checklist of ongoing and seasonal maintenance steps to help you safeguard your
EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST
DATE TIME EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST INSPECTOR: LICENSE # ADDRESS: PROPERTY OWNER: SINGLE: DOUBLE: MULTI-UNIT # OF UNITS POINT OF INSPECTION Sanitation IPMC 302.1
PROPERTY INSPECTION REPORT Property Address:
Scott Certified Member P. O. Box 9007 Indianapolis, IN 690-007 (7)-750-60 Fax: 7-876-8 PROPERTY INSPECTION REPORT Property Address: Prepared for: Inspection Inspector: Lou Buehler Inspection #: BUYERS
Inspection Report Atlanta Strip Mall Commercial Building Property Address:
Page 1 of 25 Inspection Report Atlanta Strip Mall Property Address: Smyrna GA 30082 Page 2 of 25 South East Building Consultants Ray Thoroman Serving the entire State of Georgia 6 678-410-3005 Page 3 of
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!
U.S. Department of Housing and Urban Development Office of Public and Indian Housing A Good Place to Live! Introduction Having a good place to live is important. Through your Public Housing Agency (or
Building Condition Assessment Report
C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
19 Ellis Park Road, Toronto
19 Ellis Park Road, Toronto Inspection Report September 9, 2015 19 Ellis Park Road, Toronto Inspection Report Overall Condition: This is a solidly built older double-brick home that is in fairly original
Simplify. Homeownership
Simplify Homeownership Home Pulse An Innovative Program To Maintain Your Home. The Home Pulse Preventive Maintenance Plan will keep your home looking great, dramatically slow the deterioration process
Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)355-1748
Inspection Report provided by: Delaware Property Inspection Inspector: Richard Hiddemen (302)355-1748 ASHI # 243377 DPR #H4-0000018 DDA #06-444 Delaware 1992105842 Wilmington #03857 New Castle #2010-845
INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas
5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 [email protected] INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction
RRIO Checklist. Use of checklist: Definitions: Limitations
CITY OF SEATTLE RENTAL REGISTRATION AND INSPECTION ORDINANCE (RRIO) RRIO Checklist Use of checklist: Property owners will use the RRIO Checklist to confirm that their rental housing properties and units
Propery Inspection Report
Propery Inspection Report Cover Page,, Ok Inspection prepared for: Date of Inspection: 9/28/2014 Time: 8:30 AM Age of Home: 2011 MOL Weather: Clear 62 degrees Inspector: License #130 5400 Hwy 177, Marland,
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: Somewhere, FL CLIENT: GAIA GC ID No: 2015000 DATE: 12/31/2015 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792 FLORIDA
Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire.
Attached Garage Garage-house door isn't auto-closing. Recommend installing hinges with springs or an automatic door closing device so door closes automatically to prevent vehicle fumes from entering building.
Inspecting to a higher standard.
Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com [email protected]
Home Inspection Report
Home Inspection Report 555 Wind Way, Fake City, OR 54645 Inspection Date: Monday May 12, 2014 Prepared For: John Doe Prepared By: House to Home 3468 N. Bartlett Ave Milwaukee, WI 53211 262-754-5973 [email protected]
Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections
Page 1 of 37 Inspection Report Prepared For: Sampath Sample Property Address: Alpharetta, GA 30004 Atlanta Home Inspections Matthew A Thoroman 6625 Hwy. 53 E. Ste. 410-151 Dawsonville Ga 30534 (678)-410-8062
CONDITION OF QUALITY ITEMS
CONDITION OF QUALITY ITEMS FOUNDATION Always look for moisture problems and any bulges or irregularities in the walls. Lines on the walls or floors may indicate water problems. Have these been cured? If
Home Inspection Report
Home Inspection Report Report Number: 144 For The Property Located On: 123 Any Street 27587 Prepared For Exclusive Use By: Mr. Sample N/A,,, Report Prepared By: Edward Carapezza; License No.: 3447 Inspector
Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen
Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen May 2008 Wisconsin Area PO BOX 115 Lake Geneva, WI 53147 CELL (414) 550-4765 Home Performance with ENERGY STAR Evaluation Report Customer
The BrickKicker is pleased to present this professional home inspection report for the property located at: 123 Main St. Happy Town, IL 65432
The BrickKicker is pleased to present this professional home inspection report for the property located at: 123 Main St. Happy Town, IL 65432 inspected on 05/26/2014 For more information please contact
If there are any further questions with regards to the report or inspection, please call.
National Home Inspection Ltd. 1055 Woodbine Avenue Toronto, Ontario M4C 4C2 TEL: (416) 467-7809 FAX: (416) 429-5443 April 15, 2014 SUMMARY INSPECTION REPORT PROPERTY: 75 Fairlawn Avenue, Toronto, Ontario
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792
Protecting Your Home From Water Damage
1 P a g e Protecting Your Home From Water Damage The first signs of water damage might seem trivial. But warnings like water stains on the ceilings or a leak under the kitchen sink can lead to real problems,
INSPECTION CONNECTION, INC.
INSPECTION CONNECTION, INC. Professional Real Estate Inspections and Consulting Services 2932 West 100 th Street Evergreen Park, IL 60805 708-346-0708 800-573-1113 [email protected] 312-429-1230
Home Inspection Report
123 Somewhere Street Somewhere, US 12345 Home Inspection Report Yourtown, US 12345 Page 1 of 20 Marginal Summary This summary is not the entire report. The complete report may include additional information
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066
Page 1 of 58 Inspection Report Prepared For: Atlanta Commercial Customer Property Address: Building 5 Marietta, GA 30066 Superior Home Inspections Ray Thoroman 8070 Ivy Shaw Dr. Gainesville,GA 30506 678-410-3005
Table of Contents. Definitions General Information Lots and Grounds Exterior Surface and Components Garage/Carport Electrical
Page 1 of 24 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior Surface and Components 4 Garage/Carport 5 Electrical 5 Roof 7 Air Conditioning 8 Fireplace/Wood Stove 8 Heating
New Home Walk-Through Package
New Home Walk-Through Package Carrying out a Successful Walk-through Before Closing John MacDonald Architect inc. The Courtyard @ Bonnie Stuart, 141 Whitney Place Suite 101, Kitchener, ON. N2G 2X8 New
Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick
Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick Prepared by: The Inspection Guys www.inspectionguys.com 16 Mt. Bethel Road, Suite 171 Warren, NJ 07059 800-903-0670 Fax: 732-238-7092
HOME INSPECTION REPORT
Edgewood Home Inspections, Inc. 407 W. Smith Valley Rd. #1032 Greenwood, IN 46142 (317) 833-6048 HOME INSPECTION REPORT Indianapolis IN 46000 Inspector's Name: License Number: Scott Kissel HI00800073 TABLE
Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10
Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 PROPERTY DESCRIPTION PROPERTY INSPECTED: INSPECTION ADDRESS: 4722 Baltimore Avenue
STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:
STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: 61-30.801 Standards of Practice, General. (1) Home inspections performed to these Standards of Practice are intended to provide the client with information
GeorgiaHomePros.com. 6858 Yellow Creek Road Ball Ground, GA 30107 770-893-2271 www.georgiahomepros.com [email protected] Inspected By: Scott Webb
GeorgiaHomePros.com 6858 Yellow Creek Road Ball Ground, GA 30107 770-893-2271 www.georgiahomepros.com [email protected] Inspected By: Scott Webb Home Inspection Report Prepared For: Jack & Diane Samples
BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396
BUILDING ANALYSIS REPORT July 25, 2014 John Doe 1234 Smith Road Atlanta, Georgia 30396 Agent: Ausker and Barbara Morris AT Morris Realty Group, Inc. 3162 Johnson Ferry Road, Suite 260-25 Marietta, Georgia
Estimating Database Checklist
Estimating Database Checklist If you are creating a new estimating database for projects, the following list offers a thorough listing of Main and Sub Categories. You can also use it as a checklist to
Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102
Page 1 of 26 Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102 Printed Friday, January 14, 2011 Inspected By: None None Realtor NONE Client Information: Name, Your 123 Street
Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668
Inspection Report Property Address: 123 Dream Home Way Frisco, CO 80443 Prepared for: Inspector: Tim Nixon Tim Nixon Inspection date: 3/28/2014 1 of 9 General Information Property Information Address:
Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations
Open House and Home Tour Checklist
1 The House Address: Number of floors: Listing price: Basement? Property tax: Outdoor space? Eugh closet space? Style: Eugh storage space? Square footage: Room for expansion? Number of bedrooms: What appliances
INVOICE. DATE: May 11, 2005. DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.
INVOICE DATE: May 11, 2005 CLIENT: The Buyer DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl. TOTAL FEE: $ See Schedule Tom Villani Hallmark Inspection
Real Estate Inspection Report
1010 22nd Ave N Naples, Florida 34103 Real Estate Inspection Report 470 Golden Gate Blvd W Naples, Florida 34120 Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior
SNS Home Inspections LLC
Cover Page SNS Home Inspections LLC Property Inspection Report 32750 Inspection prepared for: Donald Duck Real Estate Agent: - Date of Inspection: 2/6/2015 Time: 2:00 PM Age of Home: 1980 Size: 2453 sq
COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)
COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.
Pre-Drywall Inspection Report
SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion
Does Wall Township require an inspection by the building department on resale of a home?
Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,
Inspection Report. Mr. Happy 2 flat owner. Property Address: Focal Point Home Inspection Ltd.
Page 1 of 35 Inspection Report Mr. Happy Property Address: Joseph Poelsterl 450.010220 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Page 2 of 35 Table of Contents Cover Page Table of Contents
City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage
City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage Property Address: Company Name: Contractor Name: Contractor Address: City: State: Zip: License Number: Phone Number
Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010
Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010 Tel: (804) 378-0861 [email protected] Inspection
8629 S. Kimbark, Chicago, IL PROJECT SPECIFIC SCOPE:
8629 S. Kimbark, Chicago, IL PROJECT SPECIFIC SCOPE: General: Remove existing base molding and install new 4-1/4 base molding throughout and spray white Remove existing window and door trim and install
WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME
WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through
Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN 12345. 1234 USA Drive. Morris Home Inspection Group, LLC
Inspection Report Mr. Sample Sample Property Address: 1234 USA Drive Indianapolis IN 12345 1234 USA Drive Morris Home Inspection Group, LLC Cedric Morris HI01200039 Fishers, IN 46037 317-550-6281 Table
SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX
SUMMARY REPORT Report Number: 1860 Inspection Date: Saturday, February XX, XXXX Property Address: XX XXXXX XXX Toronto, ON XXX XZX Client Name: Xxxx Xxxxxxxxxxxxx Prepared by: Andrew Marioselva BSc,CHI
A and S Property Inspector
Cover Page A and S Property Inspector Property Inspection Report Inspection prepared for: xxxxx xxxxx Real Estate Agent:.. - Date of Inspection: 8/25/2014 Time: 10am Age of Home: 1999 Size: 1841 Weather:
Stanley Neighborhood Series
Stanley Neighborhood Series On the Outside - Appealing Exteriors Maintenance Free Double 5 Siding Per Design 25Year Shingles New and Appealing Exterior Elevations Portico, Porches and Covered Entry Per
API America s Property Inspections
API America s Property Inspections DESCRIPTION OF HOUSE: Ranch CONCLUSION Mr. xxxx INSPECTION ADDRESS 00/00/2011 APPROXIMATE AGE: 10 years (according to the homeowner) TYPE OF BASIC CONSTRUCTION: Poured
South Carolina Home Inspector Standards of Practice
South Carolina Home Inspector Standards of Practice The following Standards provide guidelines for the Residential Home Inspector and outline what the Residential Home Inspector should observe, identify,
Home Inspection Report
Home Inspection Report 1234 School House Road Yourtown, US 12345 Prepared for: Bob Smith Prepared by: Your Company Name Here 9600 Colerain Ave Suite 110 Cincinnati, OH 45215 17:26 August 02, 2006 Page
Building Permits: When are they required?
Building Permits: When are they required? Generally, you need to obtain a building permit from the City whenever you construct, enlarge, alter, repair, move, remove, improve, convert, or demolish a building
CONSERVATION MAINTENANCE WORKSHEET Universal Checklist
3.1 SITE 1 Concrete curbs Check for cracks, spalling, growth from joints X 2 Stone curbs Check for cracks, spalling, growth from joints X 3 Concrete walkways Look for uneven surfaces, ponding, growth from
Home Inspection Report
Home Inspection Report?? Tremont Ave, Westfield, NJ 07090 Inspection Date: Tuesday March 31, 2015 Prepared For: Tim Jones Prepared By: Cornerstone Home Inspection 9736504151 Report Number: 33115 Inspector: