Vari Inspection Services
|
|
|
- Lambert Johnston
- 9 years ago
- Views:
Transcription
1 Cover Page Vari Inspection Services Property Inspection Report Inspection prepared for: Sample Real Estate Agent: None - Date of Inspection: 5/13/2015 Inspector: Tony Vari License # HI STRD 54 #106, Lutz, FL Phone: Fax: [email protected] variinspectionservices.com
2 Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expenses to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all of the pages of the report as the summary alone does not explain all the issues. All repairs must be done by a licensed &bonded trade or profession. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Grounds Page 5 Item: 4 Gate Condition Gates are sagging. Repair as needed. Page 6 Item: 5 Patio and Porch Deck Floor boards rotted. Warped deck boards observed. Repair or replace as needed. Page 6 Item: 6 Stairs & Handrail Spindles missing; safety hazard. Rotted wood observed on front porch stairs. Non-conforming steps at rear deck location, possible safety hazard. Page 7 Item: 8 GFCI No Ground Fault Circuit Interrupter (GFCI) protection of home electrical outlets was provided in the home at the time of inspection. Although GFCI protection may not have been required at the time the home was built, for safety reasons, consider upgrading the electrical system to include GFCI protection. Page 8 Item: 13 Fence Condition Wood deterioration observed. Suggest repairs/replacement as needed. Exterior Areas Page 10 Item: 1 Doors Rotted door and jam observed on front and back doors. Repair or replace as needed. Door pin latch was broken at time of inspection. Replace as needed. Page 10 Item: 2 Siding Condition Deteriorated siding observed on several locations of both the main house and guest house. Evidence of insect activity and/or insects around exterior of house. Recommend evaluation by licensed pest control specialist/exterminator. Inspector was unable to determine how much structural damage has been done by termite infestation. Recommend further evaluation from a licensed structural contractor. Page 12 Item: 3 Eaves & Facia Deteriorating and rotted fascia observed on both structures. Replace as needed. Foundation Page 13 Item: 1 Access Panel Limited inspection from the access area only. Limited review due to falling insulation. Roof Page 14 Item: 1 Roof Condition Evidence of roof leaks at roofs perimeter. Recommend further evaluation from a licensed roofing contractor. Guest house roof appears to be at the end of its useful life. Recommend further evaluation from a licensed roofing contractor. Page 1 of 40
3 Attic Page 16 Item: 2 Structure Vermin activity observed in the attic. Vermin can damage insulation & electrical wiring. Recommend a professional pest contractor evaluate for treatment. Page 16 Item: 3 Ventilation No soffit venting observed on both structures. Electrical Page 18 Item: 1 Electrical Panel Parallel wiring observed in main and sub panel feeds. Recommend further evaluation from a licensed electrical contractor. Water Heater Page 24 Item: 5 Overflow Condition A Temperature Pressure Relief Valve (TPR Valve) present. This safety valve releases water (and thus relieves pressure) if either the temp or pressure in the tank gets too high. The TPR valve discharge tube must be made of copper, iron, or CPVC (NOT regular PVC). It must terminate within 6" above the floor--the end cannot be threaded or have a fitting. Recommend running drain plan discharge to exterior of living area. Interior Areas Page 25 Item: 3 Doors The interior doors did not operate properly at time of inspection. Adjust as needed. Interior doors rubbed on carpet at time of inspection. Repair as needed. Page 26 Item: 5 Smoke Detectors The smoke alarm battery needs to be replaced. Page 28 Item: 9 Window Condition Loose tension rods observed at front room right window location. Recommend further evaluation from a licensed window contractor. Missing window lock at front center window location. Bathroom 1 Page 29 Item: 5 Doors Hollow wood doors. Damaged baseboard observed behind toilet. Repair as needed. Page 29 Item: 7 GFCI No GFCI protection present, suggest installing GFCI protected receptacles for safety. Page 31 Item: 14 Bath Tubs Chipped finish observed. Missing stopper noted. Page 32 Item: 16 Toilets A loose toilet and/or loose/soft sub-flooring was observed. This can indicate damage to the sub-flooring beneath the fixture and floor covering. This condition is not visible or fully accessible to the inspector without destructive investigation. Client is advised to seek further review by a licensed plumbing contractor prior to closing for repairs/replacement as required. Bathroom 2 Page 33 Item: 7 GFCI No GFCI protection present, suggest installing GFCI protected receptacles for safety. Page 34 Item: 14 Sinks Stopper is missing. Kitchen Page 36 Item: 6 Range condition Right rear burner needs replacing. Page 38 Item: 14 GFCI No GFCI protection present, suggest installing GFCI protected receptacles for safety. Page 2 of 40
4 We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific noncode, non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. Page 3 of 40
5 1. Attendance 2. Home Type 3. Occupancy Inspection Details In Attendance: Client present Selling Agent present Home Type: Single Family Home Occupancy: Vacant Page 4 of 40
6 Grounds 1. Driveway and Walkway Condition Materials: No driveway noted. 2. Grading No major system safety or function concerns noted at time of inspection. 3. Vegetation Observations No major system safety or functional concerns noted at time of inspection. 4. Gate Condition Materials: Wood Gates are sagging. Repair as needed. Page 5 of 40
7 5. Patio and Porch Deck Floor boards rotted. Warped deck boards observed. Repair or replace as needed. 6. Stairs & Handrail Spindles missing; safety hazard. Rotted wood observed on front porch stairs. Non-conforming steps at rear deck location, possible safety hazard. Page 6 of 40
8 7. Grounds Electrical 8. GFCI No Ground Fault Circuit Interrupter (GFCI) protection of home electrical outlets was provided in the home at the time of inspection. Although GFCI protection may not have been required at the time the home was built, for safety reasons, consider upgrading the electrical system to include GFCI protection. 9. Plumbing Materials: Copper piping noted. Main water shut off observed. Right of structure. Page 7 of 40
9 10. Water Pressure 11. Exterior Faucet Condition Location: Left of structure. Right of structure. Appears Functional. 12. Patio and Porch Condition 13. Fence Condition Materials: Wood Wood deterioration observed. Suggest repairs/replacement as needed. Page 8 of 40
10 Page 9 of 40
11 1. Doors Exterior Areas Rotted door and jam observed on front and back doors. Repair or replace as needed. Door pin latch was broken at time of inspection. Replace as needed. 2. Siding Condition Deteriorated siding observed on several locations of both the main house and guest house. Evidence of insect activity and/or insects around exterior of house. Recommend evaluation by licensed pest control specialist/exterminator. Inspector was unable to determine how much structural damage has been done by termite infestation. Recommend further evaluation from a licensed structural contractor. Page 10 of 40
12 3. Eaves & Facia Deteriorating and rotted fascia observed on both structures. Replace as needed. Page 11 of 40
13 4. Exterior Paint Suggest sealing/caulking around doors and windows as part of routine maintenance. Page 12 of 40
14 1. Access Panel Foundation Limited inspection from the access area only. Limited review due to falling insulation. 2. Post and Girders Support Material: Block Pillars Page 13 of 40
15 1. Roof Condition Roof Materials: Inspected from Roof. Materials: Asphalt shingles noted. Evidence of roof leaks at roofs perimeter. Recommend further evaluation from a licensed roofing contractor. Guest house roof appears to be at the end of its useful life. Recommend further evaluation from a licensed roofing contractor. Page 14 of 40
16 Page 15 of 40
17 1. Access 2. Structure Access at hallway ceiling. Attic Vermin activity observed in the attic. Vermin can damage insulation & electrical wiring. Recommend a professional pest contractor evaluate for treatment. 3. Ventilation 4. Duct Work Ridge exhaust venting noted. No soffit venting observed on both structures. Page 16 of 40
18 5. Electrical 6. Attic Plumbing Most areas not accessible due to insulation. PVC plumbing vents 7. Insulation Condition Materials: Unfinished fiberglass batts noted. Depth: Insulation averages about 8 inches in depth Insulation level in the attic is typical for homes this age Page 17 of 40
19 1. Electrical Panel Electrical Location: Exterior of structure. Location: Located at the guest house. Parallel wiring observed in main and sub panel feeds. Recommend further evaluation from a licensed electrical contractor. Page 18 of 40
20 2. Main Amp Breaker 150 amp 3. Cable Feeds There is an overhead service drop noted. Page 19 of 40
21 4. Breakers Materials: Copper non-metallic sheathed cable noted. All of the circuit breakers appeared serviceable. Page 20 of 40
22 Heat/AC The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the climate control system for the structure. The goal of these systems is to keep the occupants at a comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be powered by other sources such as butane, oil, propane, solar panels, or wood. The inspector will usually test the heating and air conditioner using the thermostat or other controls. For a more thorough investigation of the system please contact a licensed HVAC service person. 1. Heater Condition Materials: The furnace is located in the laundry room Materials: The home has a split system. 2. Refrigerant Lines No defects found. 3. AC Compress Condition Compressor Type: Electric Location: The compressor is located on the exterior grounds. The typical temperature differential split between supply and return air in an air conditioner of this type is degrees F. This system responded and achieved an acceptable differential temperature of 19 degrees F. Page 21 of 40
23 4. Filters 5. Thermostats Location: Located in a filter grill in a hall area wall. MAINTENANCE: The air filter(s) should be inspected at least monthly and cleaned or replaced as required. There are two types of filters commonly used: (1) Washable filters, (constructed of aluminum mesh, foam, or reinforced fibers) these may be cleaned by soaking in mild detergent and rising with water. Or (2) Fiberglass disposable filters that must be REPLACED before they become clogged. Remember that dirty filters are the most common cause of inadequate heating or cooling performance. Location: Hallway Page 22 of 40
24 Water Heater 1. Water Heater Condition Heater Type: Electric Location: The heater is located in the laundry room. Tank appears to be in satisfactory condition -- no concerns. 2. TPRV Appears to be in satisfactory condition -- no concerns. 3. Number Of Gallons 40 gallons 4. Plumbing Materials: Copper No deficiencies observed at the visible portions of the supply piping. Page 23 of 40
25 5. Overflow Condition Materials: PVC A Temperature Pressure Relief Valve (TPR Valve) present. This safety valve releases water (and thus relieves pressure) if either the temp or pressure in the tank gets too high. The TPR valve discharge tube must be made of copper, iron, or CPVC (NOT regular PVC). It must terminate within 6" above the floor--the end cannot be threaded or have a fitting. Recommend running drain plan discharge to exterior of living area. Page 24 of 40
26 Interior Areas The Interior section covers areas of the house that are not considered part of the Bathrooms, Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of hallways, foyer, and other open areas. Within these areas the inspector is performing a visual inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal items in the structure may prevent the inspector from viewing all areas on the interior. The inspector does not usually test for mold or other hazardous materials. A qualified expert should be consulted if you would like further testing. 1. Ceiling Fans Operated normally when tested, at time of inspection. 2. Closets 3. Doors The closets are in serviceable condition. Hollow wood doors. The interior doors did not operate properly at time of inspection. Adjust as needed. Interior doors rubbed on carpet at time of inspection. Repair as needed. Page 25 of 40
27 4. Electrical 5. Smoke Detectors The smoke alarm battery needs to be replaced. Page 26 of 40
28 6. Window-Wall AC or Heat 7. Ceiling Condition 8. Wall Condition 9. Window Condition Materials: There are drywall ceilings noted. Materials: Drywall walls noted. Materials: Aluminum framed single hung window noted. Loose tension rods observed at front room right window location. Recommend further evaluation from a licensed window contractor. Missing window lock at front center window location. Page 27 of 40
29 10. Floor Condition Materials: Carpet noted. Vinyl floors observed. Page 28 of 40
30 1. Locations 2. Cabinets 3. Ceiling Condition 4. Counters 5. Doors Locations: Main House Bathroom 1 Materials: There are drywall ceilings noted. Plastic laminate tops noted. Hollow wood doors. Damaged baseboard observed behind toilet. Repair as needed. 6. Electrical 7. GFCI 8. Exhaust Fan No GFCI protection present, suggest installing GFCI protected receptacles for safety. Page 29 of 40
31 9. Floor Condition 10. Heating 11. Mirrors Materials: Sheet vinyl flooring is noted. Central heating and cooling noted in this room. At the time of the inspection, all appeared to be functioning and in serviceable condition. 12. Plumbing 13. Shower Walls FPR noted. Page 30 of 40
32 14. Bath Tubs Caulk/seal tub perimeter as a part of routine maintenance. Chipped finish observed. Missing stopper noted. 15. Sinks Page 31 of 40
33 16. Toilets A loose toilet and/or loose/soft sub-flooring was observed. This can indicate damage to the sub-flooring beneath the fixture and floor covering. This condition is not visible or fully accessible to the inspector without destructive investigation. Client is advised to seek further review by a licensed plumbing contractor prior to closing for repairs/replacement as required. Page 32 of 40
34 1. Locations 2. Cabinets 3. Ceiling Condition 4. Counters 5. Doors Locations: Guest house Bathroom 2 Materials: There are drywall ceilings noted. Plastic laminate tops noted. Hollow wood doors. 6. Electrical 7. GFCI 8. Exhaust Fan 9. Floor Condition No GFCI protection present, suggest installing GFCI protected receptacles for safety. Materials: Sheet vinyl flooring is noted. 10. Heating 11. Plumbing 12. Shower Walls Fiberglass surround noted. Page 33 of 40
35 13. Bath Tubs 14. Sinks Stopper is missing. Page 34 of 40
36 15. Toilets 0bserved as functional and in good visual condition. Page 35 of 40
37 Kitchen The kitchen is used for food preparation and often for entertainment. Kitchens typically include a stove, dishwasher, sink and other appliances. 1. Cabinets 2. Counters Plastic laminate tops noted. 3. Dishwasher 4. Garbage Disposal 5. Microwave 6. Range condition Materials: Electric Right rear burner needs replacing. 7. Sinks Page 36 of 40
38 8. Vent Condition Materials: Recirculating 9. Window Condition 10. Floor Condition Materials: Aluminum framed sliding window noted. Materials: Sheet vinyl flooring is noted. 11. Plumbing 12. Ceiling Condition Materials: There are drywall ceilings noted. Page 37 of 40
39 13. Electrical 14. GFCI 15. Wall Condition No GFCI protection present, suggest installing GFCI protected receptacles for safety. Materials: Drywall walls noted. Page 38 of 40
40 1. Dryer Vent Laundry 2. Electrical 3. Floor Condition Materials: Sheet vinyl flooring is noted. 4. Plumbing Page 39 of 40
41 5. Wall Condition 6. Ceiling Condition Materials: Drywall walls noted. Materials: There are drywall ceilings noted. 7. Doors Page 40 of 40
Georgia Home Inspection Services
Cover Page Property Inspection Report My street, Anytown GA, 30000 Inspection prepared for: John Doe Inspection Date: 7/18/2011 Time: 5pm Age: 25+ Size: >1500 Weather: Clear This ranch style home is in
A and S Property Inspector
Cover Page A and S Property Inspector Property Inspection Report Inspection prepared for: xxxxx xxxxx Real Estate Agent:.. - Date of Inspection: 8/25/2014 Time: 10am Age of Home: 1999 Size: 1841 Weather:
PROPERTY INSPECTION REPORT
(850) 297-1998 1716 Monticello Dr Tallahassee, Florida 32303 PROPERTY INSPECTION REPORT THIS INSPECTION IS A DETAILED LISTING OF AREAS VISUALLY INSPECTED AT:, Tallahassee FL Client Tallahassee, FL 32304
Inspecton Report. Property Address:
Inspecton Report Provided by: National Home Inspections Inspector: Bob Smith 456 S Main Denver, CO 46312 (645) 423-3242 [email protected] www.nationalhomeservices.com Property Address: 873
SWF Home Inspections
Cover Page SWF Home Inspections Property Inspection Report Inspection prepared for: Mr & Mrs Home Buyer Real Estate Agent: My Favorite Agent - Date of Inspection: 7/4/2013 Age of Home: 2004 Size: 1568
Home Inspection Report
Report# 21009 Page 1 of 24 Home Inspection Report Property Address: 123 Maple Lane, St. Augustine, FL 32092 Prepared For: Mr. Smith Prepared By: EDGE Inspections www.edgeinspections.com PO Box 601055 Jacksonville,
COMPREHENSIVE PROPERTY INSPECTIONS
COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist
A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111
A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 Inspector Name: Tim Knight, ASHI Member 202490 Inspection No: 12121212 Inspection Date: 1/1/2012 Client: Address: John
SNS Home Inspections LLC
Cover Page SNS Home Inspections LLC Property Inspection Report 32750 Inspection prepared for: Donald Duck Real Estate Agent: - Date of Inspection: 2/6/2015 Time: 2:00 PM Age of Home: 1980 Size: 2453 sq
Home Inspection Report
4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 [email protected] Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792
www.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
Self-Home Inspection Checklist
To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections
Page 1 of 37 Inspection Report Prepared For: Sampath Sample Property Address: Alpharetta, GA 30004 Atlanta Home Inspections Matthew A Thoroman 6625 Hwy. 53 E. Ste. 410-151 Dawsonville Ga 30534 (678)-410-8062
Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois
Accurate Home Inspection of Illinois 815-260-1727 1213 Norley st. Joliet, illinois 60435 [email protected] We Inspect to Protect!!! Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave.,
Orlando Home Inspection Services
PLEASE NOTE: Orlando Home Inspection Services Serving Central Florida since 1999 P O Box 915451, Longwood, Florida, 32791-5451 Phone: (321) 228-2493 Fax: (407) 374-8505 Web: http://www.orlando-home-inspections.com
Propery Inspection Report
Propery Inspection Report Cover Page,, Ok Inspection prepared for: Date of Inspection: 9/28/2014 Time: 8:30 AM Age of Home: 2011 MOL Weather: Clear 62 degrees Inspector: License #130 5400 Hwy 177, Marland,
Summit Series Single Section and Double Section Homes
Single Section and Double Section Homes SM-01 All New 20 Wides Now Available! SM-08 Units shown with optional features SM-01-4814 42 Bedrooms 41 Bathrooms 648 Sq. Ft. SM-01-5214 42 Bedrooms 41 Bathrooms
Final Walk-Through Checklist
Final Walk-Through Checklist All Aspects Home Inspections Inc 516 731-7213 www.artofinspection.com The final walk-through gives homebuyers an opportunity to inspect a property before closing on the sale
Real Estate Inspection Report
1010 22nd Ave N Naples, Florida 34103 Real Estate Inspection Report 470 Golden Gate Blvd W Naples, Florida 34120 Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior
HOME INSPECTION CHECKLIST
CLOSING.COM LEARNING CENTER HOME INSPECTION CHECKLIST CONTENTS Attic 1 Balconies 1 Basement 1 Bathroom 2 Ceiling, Floors and Walls 2 Crawlspace 3 Decks and Porches 3 Doors and Windows 4 Drainage 4 Driveways
Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288
Page 1 of 22 Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288 Printed Friday, January 16, 2015 Inspected By: Dale Gibbs Referral Information Joe Agent Client Information:
CHRIS CURLES and ASSOCIATES INSPECTION SERVICES
CHRIS CURLES and ASSOCIATES INSPECTION SERVICES Inc. Chris Curles, President www.homeinspectionsatlanta.com [email protected] Office: 770-493-0227 Professional Member Of: GAHI # 93006 ASHI # 211725
Total Home Inspection Checklist
Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are
Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division
Code Enforcement Inspection Manual City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division LIVING ROOM 304.15 EXTERIOR DOOR(S) Check door(s) and trim for condition,
Inspection Tech. (330) 310-6559 http://www.inspectiontech.us [email protected] Inspected By: Aaron Westerburg
Inspection Tech (330) 310-6559 http://www.inspectiontech.us [email protected] Inspected By: Aaron Westerburg Inspection Tech Home Inspection Report Prepared For: Mr. & Mrs. Homebuyer Property
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES
PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: Somewhere, FL CLIENT: GAIA GC ID No: 2015000 DATE: 12/31/2015 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792 FLORIDA
PROPERTY INSPECTION REPORT Property Address:
Scott Certified Member P. O. Box 9007 Indianapolis, IN 690-007 (7)-750-60 Fax: 7-876-8 PROPERTY INSPECTION REPORT Property Address: Prepared for: Inspection Inspector: Lou Buehler Inspection #: BUYERS
INVOICE. DATE: May 11, 2005. DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.
INVOICE DATE: May 11, 2005 CLIENT: The Buyer DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl. TOTAL FEE: $ See Schedule Tom Villani Hallmark Inspection
A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS
A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS Insurance Inspection Report 1234 Main Street Tallahassee, Florida Report Prepared For: Charles Smith Report Prepared
#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check
#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check Zoning laws Deed restrictions on home size, foundation style, roof pitch, etc. Suitability (slope, wetland issues, etc.) Accessibility
Inspection Item COMMENTS
APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:
Schedule of Maintenance Fees
Schedule of Maintenance Fees Effective July 1, 2015 It is the policy of the Housing Authority of Murray not to charge for NORMAL wear and tear. However, the Housing Authority reserves the right in every
Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000
Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,
INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas
5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 [email protected] INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction
Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)355-1748
Inspection Report provided by: Delaware Property Inspection Inspector: Richard Hiddemen (302)355-1748 ASHI # 243377 DPR #H4-0000018 DDA #06-444 Delaware 1992105842 Wilmington #03857 New Castle #2010-845
CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668
Inspection Report Property Address: 123 Dream Home Way Frisco, CO 80443 Prepared for: Inspector: Tim Nixon Tim Nixon Inspection date: 3/28/2014 1 of 9 General Information Property Information Address:
HOME INSPECTION REPORT
Edgewood Home Inspections, Inc. 407 W. Smith Valley Rd. #1032 Greenwood, IN 46142 (317) 833-6048 HOME INSPECTION REPORT Indianapolis IN 46000 Inspector's Name: License Number: Scott Kissel HI00800073 TABLE
WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME
WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through
Insight Property Inspections
Cover Page Insight Property Inspections Property Inspection Report 89178 Inspection prepared for: All Sampled Real Estate Agent: Tony Dacloser - Real Estate Agent of Las Vegas Date of Inspection: 10/22/2014
API America s Property Inspections
API America s Property Inspections DESCRIPTION OF HOUSE: Ranch CONCLUSION Mr. xxxx INSPECTION ADDRESS 00/00/2011 APPROXIMATE AGE: 10 years (according to the homeowner) TYPE OF BASIC CONSTRUCTION: Poured
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER
BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE
COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)
COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.
U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!
U.S. Department of Housing and Urban Development Office of Public and Indian Housing A Good Place to Live! Introduction Having a good place to live is important. Through your Public Housing Agency (or
Housing Quality Standards Inspection Checklist
Housing Quality Standards Inspection Checklist To prevent delays, the R.T.A. must be complete and upon submission the unit must be in move in condition or an inspection will not be conducted. A Fair Housing
I NI NP R Inspected Items
6/ /07 The Inspection of the property listed above must be performed in compliance with the rules of TREC. The inspection is of conditions which are present and visible at the time of the inspection, and
Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire.
Attached Garage Garage-house door isn't auto-closing. Recommend installing hinges with springs or an automatic door closing device so door closes automatically to prevent vehicle fumes from entering building.
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com
Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809
Home Inspection Report
123 Somewhere Street Somewhere, US 12345 Home Inspection Report Yourtown, US 12345 Page 1 of 20 Marginal Summary This summary is not the entire report. The complete report may include additional information
SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX
SUMMARY REPORT Report Number: 1860 Inspection Date: Saturday, February XX, XXXX Property Address: XX XXXXX XXX Toronto, ON XXX XZX Client Name: Xxxx Xxxxxxxxxxxxx Prepared by: Andrew Marioselva BSc,CHI
Inspecting to a higher standard.
Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com [email protected]
Inspection Report Atlanta Strip Mall Commercial Building Property Address:
Page 1 of 25 Inspection Report Atlanta Strip Mall Property Address: Smyrna GA 30082 Page 2 of 25 South East Building Consultants Ray Thoroman Serving the entire State of Georgia 6 678-410-3005 Page 3 of
Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10
Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 PROPERTY DESCRIPTION PROPERTY INSPECTED: INSPECTION ADDRESS: 4722 Baltimore Avenue
Vision Home Inspection
Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the
OC Home Inspect. 333 S Crest Rd Orange, CA 92868 (714) 478-3324 www.ochomeinspect.com [email protected] Inspected By: Brian Adams
OC Home Inspect 333 S Crest Rd Orange, CA 92868 (714) 478-3324 www.ochomeinspect.com [email protected] Inspected By: Brian Adams Comprehensive Property Inspection Prepared For: Property Address:
STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:
STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: 61-30.801 Standards of Practice, General. (1) Home inspections performed to these Standards of Practice are intended to provide the client with information
ROCK-SOLID Inspections
Home Inspection Services 123 S. Main Street Chicago IL 60000 Inspection prepared for: Joe Citizen Inspection Date: 2-28-2006 Time: 4:30pm Weather: Clear 30 degrees Inspector: Rich Rochowicz 3642 W. 113th
GeorgiaHomePros.com. 6858 Yellow Creek Road Ball Ground, GA 30107 770-893-2271 www.georgiahomepros.com [email protected] Inspected By: Scott Webb
GeorgiaHomePros.com 6858 Yellow Creek Road Ball Ground, GA 30107 770-893-2271 www.georgiahomepros.com [email protected] Inspected By: Scott Webb Home Inspection Report Prepared For: Jack & Diane Samples
BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396
BUILDING ANALYSIS REPORT July 25, 2014 John Doe 1234 Smith Road Atlanta, Georgia 30396 Agent: Ausker and Barbara Morris AT Morris Realty Group, Inc. 3162 Johnson Ferry Road, Suite 260-25 Marietta, Georgia
Virginia Maintenance Code Requirements
Virginia Maintenance Code Requirements THE VIRGINIA MAINTENANCE CODE The City of Roanoke has adopted and enforces the Virginia Maintenance Code (VMC) on all existing structures located in the city. This
Stanley Neighborhood Series
Stanley Neighborhood Series On the Outside - Appealing Exteriors Maintenance Free Double 5 Siding Per Design 25Year Shingles New and Appealing Exterior Elevations Portico, Porches and Covered Entry Per
159 Morningside Avenue, Toronto
159 Morningside Avenue, Toronto Inspection Report February 6, 2013 159 Morningside Avenue, Toronto Inspection Report Overall Condition: This 60±-year-old home was extensively renovated and extended in
South Carolina Home Inspector Standards of Practice
South Carolina Home Inspector Standards of Practice The following Standards provide guidelines for the Residential Home Inspector and outline what the Residential Home Inspector should observe, identify,
Inspection Report. Joe Smith. Property Address: 2222 SW 20 St Miramar FL 33028. Coast to Coast Property Inspections
Inspection Report Joe Property Address: 2222 SW 20 St Miramar FL 33028 Coast to Coast Property Inspections Edmund Villacis HI8060 2114 N Flamingo Rd. #1277 Pembroke Pines, FL 33028 (954) 435-4443 Table
VIRGINIA HOME INSPECTIONS P.O.BOX 586 CHINCOTEAGUE ISLAND, VA 23336 PHONE 757 336-3450 [email protected]
CLIENT: DATE: LOCATION: TEMPERATURE: WEATHER CONDITIONS: PERSONS PRESENT: VIRGINIA HOME INSPECTIONS P.O.BOX 586 CHINCOTEAGUE ISLAND, VA 23336 PHONE 757 336-3450 [email protected] 1 Virginia Home Inspections
Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066
Page 1 of 58 Inspection Report Prepared For: Atlanta Commercial Customer Property Address: Building 5 Marietta, GA 30066 Superior Home Inspections Ray Thoroman 8070 Ivy Shaw Dr. Gainesville,GA 30506 678-410-3005
If there are any further questions with regards to the report or inspection, please call.
National Home Inspection Ltd. 1055 Woodbine Avenue Toronto, Ontario M4C 4C2 TEL: (416) 467-7809 FAX: (416) 429-5443 April 15, 2014 SUMMARY INSPECTION REPORT PROPERTY: 75 Fairlawn Avenue, Toronto, Ontario
Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM
Pa g e 1 o f 1 5 All About Homes, LLC Michelle M. Teague Owner 312-371-7414 Phone 773-508-6209 Fax www.michelleinspects.com [email protected] 1725 W. Granville Ave. Chicago, IL 60660 Printed
Open House and Home Tour Checklist
1 The House Address: Number of floors: Listing price: Basement? Property tax: Outdoor space? Eugh closet space? Style: Eugh storage space? Square footage: Room for expansion? Number of bedrooms: What appliances
Estimating Database Checklist
Estimating Database Checklist If you are creating a new estimating database for projects, the following list offers a thorough listing of Main and Sub Categories. You can also use it as a checklist to
GENERAL WIRING RULES FOR HOUSES
GENERAL WIRING RULES FOR HOUSES 1. Romex has to be installed in drilled holes in joists or studs even above suspended ceilings - No stapling to bottom edges of joists or studs. You may staple wire to flat
Building Permits: When are they required?
Building Permits: When are they required? Generally, you need to obtain a building permit from the City whenever you construct, enlarge, alter, repair, move, remove, improve, convert, or demolish a building
Home Inspection Report
Home Inspection Report Report Number: 144 For The Property Located On: 123 Any Street 27587 Prepared For Exclusive Use By: Mr. Sample N/A,,, Report Prepared By: Edward Carapezza; License No.: 3447 Inspector
Home Inspection Report
Home Inspection Report 555 Wind Way, Fake City, OR 54645 Inspection Date: Monday May 12, 2014 Prepared For: John Doe Prepared By: House to Home 3468 N. Bartlett Ave Milwaukee, WI 53211 262-754-5973 [email protected]
Structure Survey Findings:
Structure Survey Findings: Visible portions of the following were observed: foundations; structure to walls, columns, floors, roofs, overhang posts, and columns; attached or firmly abutting decks, balconies,
Arizona Health Care Association DISASTER PLANNING AND EMERGENCY MANAGEMENT GUIDE POST INCIDENT DAMAGE ASSESSMENT CHECKLIST
It is essential to perform a Basic Damage Assessment (BDA) following an adverse event to help ensure the safety of building occupants as well as prevent additional losses from occurring. This checklist
Property Inspection Report
Property Inspection Report 1234 Bear St., Denver, CO 80223 Prepared For: John Smith Inspection Date: 12/11/2015 Prepared By: Bill Heine, Certified Professional Inspector ResInspect, LLC 303-359-7573 Email:
EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST
DATE TIME EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST INSPECTOR: LICENSE # ADDRESS: PROPERTY OWNER: SINGLE: DOUBLE: MULTI-UNIT # OF UNITS POINT OF INSPECTION Sanitation IPMC 302.1
2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
Exterior Condition Report
Scope of Work for Property Located at: 3918-20 West Cherry Street Date: 3/10/2014 Property is: Single Family Duplex Below is the minimum requirement to meet health and safety issues. The City of Milwaukee,
INSPECTION CONNECTION, INC.
INSPECTION CONNECTION, INC. Professional Real Estate Inspections and Consulting Services 2932 West 100 th Street Evergreen Park, IL 60805 708-346-0708 800-573-1113 [email protected] 312-429-1230
Latigos Trail 911 Latigos Trail ~ Des Peres, Missouri 63131 $428,500
63131 $428,500 4 Bedroom / 3 Bath / 2 Car Garage 1,676 Sq. Ft. of Living Space Includes Finished Lower Level w/ Bedroom, Full Bath, & Recreation Room Large Lot - 105 x 150 (15,750 Sq. Ft.) For More Information
License Requirements for Persons Engaging in the Business of Inspection Practice:
SC Standards of Practice SOUTH CAROLINA RESIDENTIAL BUILDERS COMMISSION HOME INSPECTOR STANDARDS OF PRACTICE Adopted by the Residential Builders Commission May 13, 1998 PURPOSE: The purpose of a residential
Plumbing Identification and Damage Assessment Guide
Plumbing Identification and Damage Assessment Guide *Please note that not all systems will be represented exactly by these diagrams and photos. As a vendor, it is required that you familiar yourself with
CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO 44120 (216) 491-1470 POINT OF SALE CERTIFICATE OF INSPECTION
CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO 44120 (216) 491-1470 POINT OF SALE CERTIFICATE OF INSPECTION Notice Issued: November 10, 2011 File: 2011-0441 To:
you haven t seen sawgrass until you ve seen old landing & coronado drive, rehoboth beach, de 19971 302-227-8412 www.piccardhomes.
Sawgrass South Aerial Site Plan you haven t seen sawgrass until you ve seen old landing & coronado drive, rehoboth beach, de 19971 302-227-8412 www.piccardhomes.com the hudson front elevation 1 front elevation
Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102
Page 1 of 26 Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102 Printed Friday, January 14, 2011 Inspected By: None None Realtor NONE Client Information: Name, Your 123 Street
INVENTORY AND CONDITION FORM CONCERNING THE PROPERTY AT
RESIDENTIAL LEASE INVENTORY AND CONDITION FORM USE OF THIS FORM BY PERSONS WHO ARE NOT MEMBERS OF THE TEXAS ASSOCIATION OF REALTORS IS NOT AUTHORIZED. Texas Association of REALTORS, Inc. 2005 INVENTORY