Table of Contents. Definitions General Information Lots and Grounds Exterior Surface and Components Garage/Carport Electrical

Size: px
Start display at page:

Download "Table of Contents. Definitions General Information Lots and Grounds Exterior Surface and Components Garage/Carport Electrical"

Transcription

1 Page 1 of 24 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior Surface and Components 4 Garage/Carport 5 Electrical 5 Roof 7 Air Conditioning 8 Fireplace/Wood Stove 8 Heating System 9 Plumbing 10 Bathroom 11 Bedroom 12 Kitchen 13 Living Space 14 Structure 15 Summary 17

2 Page 2 of 24 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection Functional with no obvious signs of defect. Not Present Item not present or not found. Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. Marginal Item is not fully functional and requires repair or servicing. Defective Item needs immediate repair or replacement. It is unable to perform its intended function. General Information Property Information Property Address 2604 NE 50th CIR City Vancouver State WA Zip Contact Name John Doe Agency John Doe Agency JohnDoe@gmail.com Client Information Client Name Jane Doe Client Phone Fax JaneDoe@gmail.com Inspection Company Inspector Name Mindy Smith Company Name Inspection Company Address 1400 NW 2nd Avenue WA Structural Pest Inspector License # Oregon Home Inspector License # 1477 Oregon Contractor License # WA Home Inspector License # 291 City Battle Ground State WA Zip Phone Fax CPInspections@msn.com File Number 0314BEN Amount Received $ Conditions Others Present Buyer's Agent and Buyer Property Occupied Vacant Estimated Age 77 Years Entrance Faces South Inspection Date Wednesday March

3 Page 3 of 24 General Information (Continued) Start Time 2:00 PM Electric On Yes Gas/Oil On No Water On Yes Weather Light Rain Soil Conditions Wet Space Below Grade Crawl Space Building Type Single family Garage Detached Sewage Disposal City How Verified Multiple Listing Service Water Source City How Verified Multiple Listing Service Additions/Modifications Buyer to verify Permits Obtained Buyer to verify Lots and Grounds 1. Driveway: Concrete - Driveway shows signs of wear and age consistent with actual age. No 2. Marginal significat defects. Porch: Brick and Concrete - There are several large cracks observed to the front porch and stair step cracking observed in the bricks. Displacement observed at the northeast corner. Porch slopes to the east. Recommend further evaluation by a civil engineer to estimate the likely hood of further movement. Guardrails are saturated as a result of leaking gutters above. Will require repair Patio: Patio configuration is functional Grading: Flat - Keep grading flowing away from the structure. Swale: Adequate slope and depth for drainage - Water appears to be draining away from the structure Vegetation: Grass, trees, shrubs - Vegetation was trimmed away from the home Exterior Surface Drain: Surface drain - Suface drain is typical for this area.

4 Page 4 of 24 Exterior Surface and Components Siding w/wood roof trim all four sides Exterior Surface 1. Marginal Type: Wood - The siding of this home is a wood based product. Due to the age of the siding 2. Marginal it is likely that it contains lead based paint in one of the underline layers. Additional testing can be done by a EPA certified testing lab for confirmation of content. Trim: Wood - The trim most noticeably around the windows is likely original to the home there are varying degrees of decay and peeling paint observed. Recommend painting and repairs as part of typical home maintenance. Compromised wood will allow moisture intrusion. Holes observed at the back of the home will facilitate pest / bird intrusion. 3. Marginal Fascia / Eaves Wood - Fascias (most notably above the porch) are water damaged as a result of leaking gutters. This material will continue to decay if not replaced and repaired Marginal Entry Doors: Fire Rated - Weather stripping in place. Patio Door: Single door - Patio door accesses the back yard Windows: Wood - Wood Frame windows do not provide adequate insulation by today standards Marginal 9. Exterior Lighting: Surface mounted lamps front and rear - Keep front and back doors well lit to avoid trip/safety hazard Hose Bibs: Present - Exterior faucet was non operable on the day of inspection Gas Meter: Exterior surface mount at side of home - Note - the gas was not on the day of inspection 10. Main Gas Valve: Located at gas meter

5 Page 5 of 24 Garage/Carport Detached Garage 1. Type of Structure: Detached Car Spaces: 2 2. Garage Doors: Insulated aluminum - Garage door was opened and closed during this inspection Door Operation: Manual - Functional as designed Door Opener: Overhead Door Exterior Surface: Fiberboard Roof: Asphalt shingle Service Doors: Fire rated - This door must remain a fire rated door and never propped open for fire safety. Ceiling: Exposed Framing - Fire rated standards appear to be met. Walls: Exposed Framing - Fire rated standards appear to be met. Floor/Foundation: Poured concrete - Cracking is typical. Monitor for large separating or heaving. Electrical Service Size Amps: 200 Volts: VAC Service: Aluminum - Aluminum wiring is typical for service wire 120 VAC Branch Circuits: Copper - Copper wiring is typical for 120 branch circuits 240 VAC Branch Circuits: Aluminum - Aluminum wiring is typical for 240 branch circuits Smoke Detectors: Present - Smoke detectors should be installed in each bedroom as well 6. Marginal as each hallway that leads into a bedroom. Batteries should always be replaced prior to occupancy. Test Regularly. Carbon Monoxide Detectors: Missing - Each floor of every home should be equipped with a carbon monoxide detector in accordance with state law effective April Carbon monoxide is a colorless, odorless gas that can cause serious injury or death. Utility Room Electric Panel 7. Marginal Manufacturer: Push-O-Matic - Evaluation by a licensed electrician is recommended to evaluate the need for upgrades. This is an older electrical system with below standard components. Exposed electrical within the panel. Double tapped breakers observed. This will require immediate correction. Pointed screws in use for the panel - should be blunt tip for safety Leaking and rusting observed behind the panel

6 Page 6 of 24 Electrical (Continued) Manufacturer: (continued) Marginal Main Breaker Size: 200 Interior Receptacles 110V - A minimum of 2 per room sample testing was performed during inspection. Inspector found various open grounds, reversed polarity. two prong ungrounded outlets throughout the home. This electrical system should be evaluated and repaired by a licensed electrician. Damaged, exposed outlets, missing faceplates should be corrected. 10. Marginal Exterior Receptacles 110V - Two prong ungrounded outlet's observed on the front of the home. The back outlets are exposed. All exterior outlets should be three prong, ground, GFCI and protected with a weather proof cover. 11. Marginal Interior lighting 110V - Exposed boxes should be repaired. Faceplates replaced 12. Marginal AFCI: Not Present - The panel did not contain Arc Fault Circuit Interrupter (AFCI) breakers

7 Page 7 of 24 Electrical (Continued) AFCI: (continued) designed to provide fire protection by shutting off current flow should sensors detect arcing at outlets on the protected circuit. AFCI protection of electrical outlets in sleeping rooms is required in new construction. 13. Marginal GFCI: Not Present - GFCI outlets should be in place for all exterior circuits, all garage circuits, bathroom circuits and Kitchen circuits near the sink. 14. Is the panel bonded? Yes Roof While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. An actual Roof Certification by a licensed roofing contractor is the best way to ensure accurate condition of the roofing system. When the age of a roofing system cannot be verified by the seller, a Roof Certification is recommended. This will determine the remaining useful life of the roofing system. Observation of the roof surfaces and flashing was performed from the eaves with a ladder and the aid of binoculars. Exterior Roof Surface 1. Method of Inspection: Ladder at eaves, ground, street view with binoculars 2. Marginal Material: Asphalt shingle - Small amount of moss observed to the back side. Recommend cleaning. 3. Type: Gable 4. Defective Attic None - There is no visible attic access within this home. The home should have an Marginal 8. Marginal interior access so the owner can perform regular maintenance safely and efficiently. Plumbing Vents: Present - Plumbing vents were observed during this inspection. Plumbing vents can become cracked over time and regular monitoring is recommended. Electrical Mast: Underground utilities - This home utilizes underground utility service. Gutters: Present - Need cleaning - Debris in the gutters will block drainage. Overflowing gutters will contribute to roof damage, siding damage and fascia damage. Downspouts: Present - Where the downspout meets the leader there should be a gap free secure connection to prevent water from splashing or pooling near the foundation.

8 Page 8 of 24 Roof (Continued) 9. Leader/Extension: Present - Leaders should direct water underground to a drainage system or with leaders that direct water away from the home. Monitor for pooling at the foundation. Air Conditioning Unable to determine the last service date for this unit. Recommend service by a licensed HVAC technician prior to use. This inspection will not determine functionality when used under normal daily conditions. Main AC System 1. A/C System Operation: Appears serviceable 2. Exterior Unit: Pad mounted 3. Manufacturer: Lennox 4. Model Number: HS19-411V-3P 5. Area Served: Approximate Age: 7 years 6. Fuel Type: Electric Temperature Differential: 7. Type: Central Capacity: 3 Ton 8. Electrical Disconnect: Breaker disconnect Fireplace/Wood Stove For safety reasons, a fireplace and the chimney to which it is vented should be cleaned and inspected by a licensed Chimney Sweep as there may be hidden defects not seen at the time of inspection. The gas was not on to this appliance at the time of inspection for testing. Comments regarding the fireplace are based on visual observation only. Living Room Fireplace 1. Fireplace Gas - This appliance should not emit a gas smell. If this should ever occur, call the gas company immediately. 2. Fireplace Construction: Prefab - Appears to function as designed. 3. Type: Gas log 4. Fireplace Insert: Standard - Do not alter this appliance. 5. Hearth: Present - Keep flammable materials away from this space. Lower Level Family Fireplace 6. Marginal Fireplace Wood Burning - The firebox has visible cracking and damage. This should be repaired prior to use.

9 Page 9 of 24 Fireplace/Wood Stove (Continued) Type: Wood Fireplace Construction: Prefab - Appears to function as designed. Burning Fireplace Insert: Standard - Do not alter this appliance. Hearth: Present - Keep flammable materials away from this space. Heating System Unable to determine the last service date for this unit. Recommend service by a licensed HVAC technician prior to use. An inspection with an HVAC technician may also provide some indication of remaining useful life for this appliance. A service that is beyond the scope of this inspection. This inspection will not determine functionality when used under normal daily conditions. Main Heating System 1. Marginal Heating System Operation: Adequate size for home - This system could not be tested on the day of inspection due to the gas being shut off This system should be cleaned and serviced by an HVAV technician prior to the expiration of the inspection period. Manufacturer: Lennox Type: Forced air Area Served: Entire Home Fuel Type: Natural gas Blower Fan/Filter: Change regularly - Clean filter in accordance Marginal with the manufacturers instructions for this model. 6. Marginal Distribution: Metal duct - Recommend duct cleaning to remove any existing debris and to evaluate condition and connection within the duct system. Suspected asbestos tape in use around the ducks. Further testing can be performed by a EPA certified laboratory. 7. Thermostats: Programmable - Thermostat was used to operate this appliance during the inspection.

10 Page 10 of 24 Heating System (Continued) 8. Suspected Asbestos: Yes Plumbing Hot water was tested and available to all appropriate plumbing fixtures. Water lines are observed without the disruption of personal items, construction material such as insulation, plastic or drywall. Plumbing is tested for visible functional flow on the day of inspection. Testing of concealed pipe condition, drainage or waste line condition will require the services of a licensed plumber and/or a a full sewer scope provider. Both services are beyond the scope of this inspection. 1. Marginal Service Line: Present - Water service was on for this home however most plumbing fixtures did not have functional flow at the time of inspection. Low flow and pipe corrosion obstructions. Due to the condition of the plumbing and pipes it is recommended that a licensed plumber perform a full plumbing evaluation for this home to determine the extent of repairs and upgrades needed for this home to function as designed Marginal Water control valves could not be turned without using force. Main Water Shutoff: Front of house Water Lines: Galvanized - Galvanized supply piping corrodes from inside causing decreased flow-rates and will eventually require updating 4. Marginal Drain Pipes: Present - Cast iron is prone to damage due to age. Utilityt Room Water Heater 5. Marginal Water Heater Operation: Adequate size for home - The water heater is off for this home. The water heater is spilling combustion gas out of the draft diverter. This appliance must be repaired prior to use -safety hazard. Corrosion observed at the water lines. 6. Manufacturer: A.O.Smith

11 Page 11 of 24 Plumbing (Continued) 7. Type: Gas Capacity: Approximate Age: 3 Years Area Served: Entire Home 9. Marginal Seismic Strap Not Present - Water heaters should have two seismic straps in place. One 10. on the top third of the tank and one on the bottom third of the tank. Each strap should be secured into a stud. TPRV and Drain Tube: Present - The drain tube should extend to within 6-10 inches off the ground. Heights outside of this range can result in scalding// Bathroom Plumbing fixtures are tested for functional flow on the day of inspection. This inspections will not determine performance under normal daily use. Main Hall Bathroom 1. Marginal Ceiling: Painted Texture - There is visible cracking above the tub on the ceiling. 2. Walls: Painted Texture - Walls are sealed and painted 3. Floor: Vinyl floor covering - At the time of inspection, there were no immediate indications of elevated moisture levels within the floor covering. Doors: Wood Windows: Wood Frame - The sash to this window was cut. Recommend repair. Marginal Counter/Cabinet: Molded Not Inspected Sink/Basin: Molded single bowl - No water Not Inspected Faucets/Traps: Present - No water Tub/Surround: Tub shower combo Not Inspected Toilets: 1 1/2 Gallon Tank - No watere Ventilation: Electric ventilation fan - This fan was tested and operable at the time of inspection Lower Level Bathroom Bathroom 12. Ceiling: Painted Texture - Ceiling is painted and textured. 13. Walls: Wallpaper - Walls are sealed and painted 14. Floor: Concrete - At the time of inspection, there were no immediate indications of elevated moisture levels within the floor covering. Doors: Wood Not Inspected Sink/Basin: Pedestal - Very low water pressure. Recommend further evaluation with a licensed plumber Not Inspected Faucets/Traps: Present - no water Not Inspected Shower/Surround: Stand Alone - No water Spa Tub/Surround: A separate tub is in place for this home. This tub appears to be functional and operating as designed. 20. The Jets were tested during this inspection. Toilets: 1 1/2 Gallon Tank - This toilet was operated during this inspection. No noted deficiencies.

12 Page 12 of 24 Bathroom (Continued) 21. Ventilation: Electric ventilation fan - This fan was tested and operable at the time of inspection Upper Level Bathroom Bathroom 22. Ceiling: Painted Texture - Ceiling is painted and textured. No indications of water penetration. Walls: Painted Texture - Walls are sealed and painted Floor: Vinyl floor covering - At the time of inspection, there were no immediate indications of elevated moisture levels within the floor covering. Doors: Wood Windows: Aluminum Frame Counter/Cabinet: Vinyl - At the time of inspection, there were no immediate indications of elevated moisture levels within the cabinets. Not Inspected Sink/Basin: Porcelain coated - no water Not Inspected Faucets/Traps: Present - no water Not Inspected Toilets: 1 1/2 Gallon Tank - No water Ventilation: Electric ventilation fan - This fan was tested and operable at the time of inspection Bedroom Main Level South Bedroom 1. Closet: Present - Closet is functional as designed. 2. Ceiling: Popcorn - Ceiling is painted and textured. No indications of water penetration. 3. Walls: Painted Texture - Walls are sealed and painted 4. Floor: Carpet - Floor covering is typical for single family home 5. Doors: Wood - Bedroom door functional at present 6. Marginal Windows: Wood Frame - The sash was cut to this window. There is a small crack in this window on the upper left corner. Recommend repair. HVAC Source: Heating system register - Tested during inspection 7. Main level North Bedroom 8. Closet: Present - Closet is functional as designed. 9. Ceiling: Popcorn - Ceiling is painted and textured. No indications of water penetration. 10. Walls: Painted Texture - Walls are sealed and painted 11. Floor: Carpet - Floor covering is typical for single family home 12. Doors: Wood - Bedroom door functional at present 13. Windows: Wood Frame - Monitor windows for moisture intrusion 14. HVAC Source: Heating system register - Tested during inspection Upper Level West Bedroom 15. Closet: Present - Closet is functional as designed. 16. Ceiling: Popcorn - Ceiling is painted and textured. No indications of water penetration. 17. Walls: Painted Texture - Walls are sealed and painted 18. Floor: Carpet - Floor covering is typical for single family home 19. Doors: Wood - Bedroom door functional at present

13 Page 13 of 24 Bedroom (Continued) 20. Marginal Windows: Wood Frame - Both windows have the sash's cut. Recommend repair. 21. HVAC Source: Convection baseboard - Tested during inspection Upper Level East Bedroom 22. Marginal Closet: Present - Moisture observed around the plumbing stack Marginal 28. Ceiling: Popcorn - Ceiling is painted and textured. No indications of water penetration. Walls: Painted Texture - Walls are sealed and painted Floor: Carpet - Floor covering is typical for single family home Doors: Wood - Bedroom door functional at present Windows: Wood Frame - The right window has the sash cut and the lock is broken. Recommend repair. HVAC Source: Convection baseboard - Tested during inspection Kitchen Long term functionality of kitchen appliances is outside the scope of this inspection. During the course of testing various electrical,gas and or plumbing components, items will be turned on for operability. An "acceptable" rating for appliances indicates the item performed as expected. Ongoing, daily use of any component may reveal concerns not apparent at the time of inspection. Vent components behind wood box concealers are not viewed past the point of operation. Main Level Kitchen 1. Marginal Cooking Appliances: Present - Front right burner does not function Marginal Ventilator: Present - Present above the stove. Dishwasher: Present - This dishwasher does not have an air gap or an air gap loop. Recommend the installation of an air gap loop to prevent back siphoning from this appliance.

14 Page 14 of 24 Kitchen (Continued) 4. Air Gap Present? No 5. Marginal Sink: Present - This dishwasher doesn't have a air gap or air gap loop. Recommend the installation of a air gap loop to prevent back siphoning from this appliance. Plumbing/Fixtures: Present - Functional design for intended use. Counter Tops: Tile - Functional material for intended use. Cabinets: Wood - At the time of inspection, there were no immediate indications of elevated moisture levels within the cabinets. Ceiling: Painted Texture - The ceiling was sealed and painted with no visible indications of moisture intrusions. Walls: Painted Texture - The walls were sealed and painted. Floor: Wood - At the time of inspection, there were no immediate indications of elevated moisture levels within the floor covering. Windows: Wood Frame Living Space Living Room - Living Space 1. Closet: Present - Coat closet present 2. Ceiling: Popcorn - Ceiling is painted and textured. No indications of water penetration. 3. Walls: Painted Texture - Walls are sealed and painted 4. Floor: Wood - Floor covering is typical for single family home 5. Windows: Wood Frame - Monitor windows for moisture intrusion as part of typical home maintenance. 6. HVAC Source: Heating system register - Heating was tested during inspection. Dining Room - Living Space 7. Ceiling: Popcorn - Ceiling is painted and textured. No indications of water penetration. 8. Walls: Painted Texture - Walls are sealed and painted 9. Floor: Wood - Floor covering is typical for single family home 10. Marginal Windows: Wood Frame - Broken window observed. Recommend repair or replacement. 11. HVAC Source: Heating system register - Heating was tested during inspection. Attic Level Bonus - Off the bedroom Living Space 12. Ceiling: Painted Texture - Ceiling is painted and textured. No indications of water Marginal 15. penetration. Walls: Painted Texture - Walls are sealed and painted Floor: Carpet - This floor is very weak and spongy. Recommend removing the carpet to reveal the underlying material and cause for the instability. Windows: Wood Frame - Monitor windows for moisture intrusion as part of typical home maintenance.

15 Page 15 of 24 Living Space (Continued) Basement Level Family - Living Space 16. Marginal Ceiling: Painted Texture - Portions of the ceiling are exposed framing (near plumbing components) These areas show water damage from previous leaking plumbing components. Wood that has been water compromised will continue to decay until it is replaced. 17. Marginal Walls: Wood - Wood paneling in place. This material is concealing the wall from inspection and observation. 18. Floor: Concrete - Floor covering is typical for single family home 19. HVAC Source: Heating system register - Heating was tested during inspection. Basement Utility Room - Living Space 20. Marginal Walls: Concrete, Exposed Framing - Walls are painted. Mildew staining observed on concrete wall surfaces. Indicates excessive moisture. Floor: Concrete - Floor covering is typical for single family home Windows: Wood Frame - Monitor windows for moisture intrusion as part of typical home maintenance. Structure 1. Marginal Foundation: Cracking - There is visible cracking to the exterior foundation. This foundation extends to the basement level walls. The walls are concealed from inspection. However water staining at the bottom of the basement walls indicates that there is water penetration to this area. The wall covering should be removed from the basement area for inspection by a civil engineer.

16 Page 16 of 24 Structure (Continued) 2. Marginal Differential Movement: Cracking - There is visible cracking throughout this home. Cracking in the upstairs master bedroom closet, cracking through the main level living and dine room ceiling, cracking at the exterior wall near the back door (on the landing), in conjunction with the front porch cracking and foundation cracking indicate the need for an evaluation with a civil engineer to determine the need for repairs, and the likely hood of further movement. 3. Marginal Piers/Posts: Basement - The post in the basement family room has visible efflorescence built up near the bottom. This is an indication of elevated moisture levels in this immediate area. Likely ground water seepage. 4. Marginal Stairs/Handrails: Missing - Handrails are missing for the attic living spaces. Final Comments We do not comment on cosmetic deficiencies and the wear and tear associated with the passage of time, which would be apparent to the average person. If any component of this report is Marginal or Defective, it is recommended that the recipient of this report seek further evaluation or assistance from a licensed professional in that field i.e Plumber, Electrician, Drainage Contractor, Roofing contractor, General Contractor and so on. There may be concealed or unreported deficiencies to areas deemed marginal or defective within this report. If an area is inaccessible within this report, it is recommended that the recipient of this report facilitate complete, unobstructed and safe access to any areas for reinspection. If the home is winterized upon arrival or de winterized within 72 hours of the inspection, there may be water leaks that will not be visibly apparent at the time of inspection.

17 Page 17 of 24 Marginal Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Lots and Grounds 1. Porch: Brick and Concrete - There are several large cracks observed to the front porch and stair step cracking observed in the bricks. Displacement observed at the northeast corner. Porch slopes to the east. Recommend further evaluation by a civil engineer to estimate the likely hood of further movement. Guardrails are saturated as a result of leaking gutters above. Will require repair. Exterior Surface and Components 2. Siding w/wood roof trim all four sides Exterior Surface Type: Wood - The siding of this home is a wood based product. Due to the age of the siding it is likely that it contains lead based paint in one of the underline layers. Additional testing can be done by a EPA certified testing lab for confirmation of content. 3. Trim: Wood - The trim most noticeably around the windows is likely original to the home there are varying degrees of decay and peeling paint observed. Recommend painting and repairs as part of typical home maintenance. Compromised wood will allow moisture intrusion. Holes observed at the back of the home will facilitate pest / bird intrusion. 4. Fascia / Eaves Wood - Fascias (most notably above the porch) are water damaged as a result of leaking gutters. This material will continue to decay if not replaced and repaired. 5. Windows: Wood - Wood Frame windows do not provide adequate insulation by today standards. 6. Hose Bibs: Present - Exterior faucet was non operable on the day of inspection

18 Page 18 of 24 Marginal Summary (Continued) Electrical 7. Carbon Monoxide Detectors: Missing - Each floor of every home should be equipped with a carbon monoxide detector in accordance with state law effective April Carbon monoxide is a colorless, odorless gas that can cause serious injury or death. 8. Utility Room Electric Panel Manufacturer: Push-O-Matic - Evaluation by a licensed electrician is recommended to evaluate the need for upgrades. This is an older electrical system with below standard components. Exposed electrical within the panel. Double tapped breakers observed. This will require immediate correction. Pointed screws in use for the panel - should be blunt tip for safety Leaking and rusting observed behind the panel 9. Utility Room Electric Panel Interior Receptacles 110V - A minimum of 2 per room sample testing was performed during inspection. Inspector found various open grounds, reversed polarity. two prong ungrounded outlets throughout the home. This electrical system should be evaluated and repaired by a licensed electrician. Damaged, exposed outlets, missing faceplates should be corrected. 10. Utility Room Electric Panel Exterior Receptacles 110V - Two prong ungrounded outlet's observed on the front of the home. The back outlets are exposed. All exterior outlets should be three prong, ground, GFCI and protected with a weather proof cover.

19 Page 19 of 24 Electrical (Continued) Exterior Receptacles (continued) 11. Utility Room Electric Panel Interior lighting 110V - Exposed boxes should be repaired. Faceplates replaced 12. Utility Room Electric Panel AFCI: Not Present - The panel did not contain Arc Fault Circuit Interrupter (AFCI) breakers designed to provide fire protection by shutting off current flow should sensors detect arcing at outlets on the protected circuit. AFCI protection of electrical outlets in sleeping rooms is required in new construction. 13. Utility Room Electric Panel GFCI: Not Present - GFCI outlets should be in place for all exterior circuits, all garage circuits, bathroom circuits and Kitchen circuits near the sink. Roof 14. Exterior Roof Surface Material: Asphalt shingle - Small amount of moss observed to the back side. Recommend cleaning. 15. Gutters: Present - Need cleaning - Debris in the gutters will block drainage. Overflowing gutters will contribute to roof damage, siding damage and fascia damage. 16. Downspouts: Present - Where the downspout meets the leader there should be a gap free secure connection to prevent water from splashing or pooling near the foundation.

20 Page 20 of 24 Marginal Summary (Continued) Fireplace/Wood Stove 17. Lower Level Family Fireplace Fireplace Wood Burning - The firebox has visible cracking and damage. This should be repaired prior to use. Heating System 18. Main Heating System Heating System Operation: Adequate size for home - This system could not be tested on the day of inspection due to the gas being shut off. This system should be cleaned and serviced by an HVAV technician prior to the expiration of the inspection period. 19. Main Heating System Blower Fan/Filter: Change regularly - Clean filter in accordance with the manufacturers instructions for this model. 20. Main Heating System Distribution: Metal duct - Recommend duct cleaning to remove any existing debris and to evaluate condition and connection within the duct system. Suspected asbestos tape in use around the ducks. Further testing can be performed by a EPA certified laboratory. Plumbing 21. Service Line: Present - Water service was on for this home however most plumbing fixtures did not have functional flow at the time of inspection. Low flow and pipe corrosion obstructions. Due to the condition of the plumbing and pipes it is recommended that a licensed plumber perform a full plumbing evaluation for this home to determine the extent of repairs and upgrades needed for this home to function as designed. Water control valves could not be turned without using force. 22. Water Lines: Galvanized - Galvanized supply piping corrodes from inside causing decreased flow-rates and will eventually require updating

21 Page 21 of 24 Plumbing (Continued) Water Lines: (continued) 23. Drain Pipes: Present - Cast iron is prone to damage due to age. 24. Utilityt Room Water Heater Water Heater Operation: Adequate size for home - The water heater is off for this home. The water heater is spilling combustion gas out of the draft diverter. This appliance must be repaired prior to use -safety hazard. Corrosion observed at the water lines. 25. Utilityt Room Water Heater Seismic Strap Not Present - Water heaters should have two seismic straps in place. One on the top third of the tank and one on the bottom third of the tank. Each strap should be secured into a stud. Bathroom 26. Main Hall ceiling. 27. Main Hall repair. Bathroom Ceiling: Painted Texture - There is visible cracking above the tub on the Bathroom Windows: Wood Frame - The sash to this window was cut. Recommend Bedroom 28. Main Level South Bedroom Windows: Wood Frame - The sash was cut to this window. There is a small crack in this window on the upper left corner. Recommend repair. 29. Upper Level West Bedroom Windows: Wood Frame - Both windows have the sash's cut. Recommend repair. 30. Upper Level East Bedroom Closet: Present - Moisture observed around the plumbing stack. 31. Upper Level East Bedroom Windows: Wood Frame - The right window has the sash cut and the lock is broken. Recommend repair.

22 Page 22 of 24 Marginal Summary (Continued) Kitchen 32. Main Level Kitchen Cooking Appliances: Present - Front right burner does not function 33. Main Level Kitchen Dishwasher: Present - This dishwasher does not have an air gap or an air gap loop. Recommend the installation of an air gap loop to prevent back siphoning from this appliance. 34. Main Level Kitchen Sink: Present - This dishwasher doesn't have a air gap or air gap loop. Recommend the installation of a air gap loop to prevent back siphoning from this appliance. Living Space 35. Dining Room - Living Space Windows: Wood Frame - Broken window observed. Recommend repair or replacement. 36. Attic Level Bonus - Off the bedroom Living Space Floor: Carpet - This floor is very weak and spongy. Recommend removing the carpet to reveal the underlying material and cause for the instability. 37. Basement Level Family - Living Space Ceiling: Painted Texture - Portions of the ceiling are exposed framing (near plumbing components) These areas show water damage from previous leaking plumbing components. Wood that has been water compromised will continue to decay until it is replaced. 38. Basement Level Family - Living Space Walls: Wood - Wood paneling in place. This material is concealing the wall from inspection and observation. 39. Basement Utility Room - Living Space Walls: Concrete, Exposed Framing - Walls are painted. Mildew staining observed on concrete wall surfaces. Indicates excessive moisture.

23 Page 23 of 24 Marginal Summary (Continued) Structure 40. Foundation: Cracking - There is visible cracking to the exterior foundation. This foundation extends to the basement level walls. The walls are concealed from inspection. However water staining at the bottom of the basement walls indicates that there is water penetration to this area. The wall covering should be removed from the basement area for inspection by a civil engineer. 41. Differential Movement: Cracking - There is visible cracking throughout this home. Cracking in the upstairs master bedroom closet, cracking through the main level living and dine room ceiling, cracking at the exterior wall near the back door (on the landing), in conjunction with the front porch cracking and foundation cracking indicate the need for an evaluation with a civil engineer to determine the need for repairs, and the likely hood of further movement. 42. Piers/Posts: Basement - The post in the basement family room has visible efflorescence built up near the bottom. This is an indication of elevated moisture levels in this immediate area. Likely ground water seepage. 43. Stairs/Handrails: Missing - Handrails are missing for the attic living spaces.

24 Page 24 of 24 Defective Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Roof 1. Attic None - There is no visible attic access within this home. The home should have an interior access so the owner can perform regular maintenance safely and efficiently.

Home Inspection Report

Home Inspection Report 4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 tripleainspections@gmail.com Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:

More information

Inspecton Report. Property Address:

Inspecton Report. Property Address: Inspecton Report Provided by: National Home Inspections Inspector: Bob Smith 456 S Main Denver, CO 46312 (645) 423-3242 bob@nationalhomeinspections.com www.nationalhomeservices.com Property Address: 873

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Cincinnati, Ohio 45000 Prepared for: Dean Murphy Prepared by: BEDROCK ENTERPRISES, INC. 4060 Simca Lane Cincinnati, OH 45211 20:13 July 07, 2008 Page 1 of 18 Definitions NOTE: All

More information

HOME INSPECTION CHECKLIST

HOME INSPECTION CHECKLIST CLOSING.COM LEARNING CENTER HOME INSPECTION CHECKLIST CONTENTS Attic 1 Balconies 1 Basement 1 Bathroom 2 Ceiling, Floors and Walls 2 Crawlspace 3 Decks and Porches 3 Doors and Windows 4 Drainage 4 Driveways

More information

Real Estate Inspection Report

Real Estate Inspection Report 1010 22nd Ave N Naples, Florida 34103 Real Estate Inspection Report 470 Golden Gate Blvd W Naples, Florida 34120 Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior

More information

Vision Home Inspection

Vision Home Inspection Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the

More information

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000 Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,

More information

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT (850) 297-1998 1716 Monticello Dr Tallahassee, Florida 32303 PROPERTY INSPECTION REPORT THIS INSPECTION IS A DETAILED LISTING OF AREAS VISUALLY INSPECTED AT:, Tallahassee FL Client Tallahassee, FL 32304

More information

Inspection Tech. (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg

Inspection Tech. (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg Inspection Tech (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg Inspection Tech Home Inspection Report Prepared For: Mr. & Mrs. Homebuyer Property

More information

Aztec Property Inspections 2719 Mission Blvd San Diego, CA 92109 (858) 245-9329. 6352 Some Road San Diego, CA 92114

Aztec Property Inspections 2719 Mission Blvd San Diego, CA 92109 (858) 245-9329. 6352 Some Road San Diego, CA 92114 2719 Mission Blvd San Diego, CA 92109 (858) 245-9329 Client: Could Be You 6352 Some Road San Diego, CA 92114 Page 1 of 14 Defective Summary This summary is not the entire report. The complete report may

More information

A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111

A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 Inspector Name: Tim Knight, ASHI Member 202490 Inspection No: 12121212 Inspection Date: 1/1/2012 Client: Address: John

More information

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809

More information

Home Inspection Report

Home Inspection Report 123 Somewhere Street Somewhere, US 12345 Home Inspection Report Yourtown, US 12345 Page 1 of 20 Marginal Summary This summary is not the entire report. The complete report may include additional information

More information

Home Inspection Report

Home Inspection Report Report# 21009 Page 1 of 24 Home Inspection Report Property Address: 123 Maple Lane, St. Augustine, FL 32092 Prepared For: Mr. Smith Prepared By: EDGE Inspections www.edgeinspections.com PO Box 601055 Jacksonville,

More information

Georgia Home Inspection Services

Georgia Home Inspection Services Cover Page Property Inspection Report My street, Anytown GA, 30000 Inspection prepared for: John Doe Inspection Date: 7/18/2011 Time: 5pm Age: 25+ Size: >1500 Weather: Clear This ranch style home is in

More information

Home Inspection Report

Home Inspection Report 123 Somewhere Street Somewhere, US 12345 Home Inspection Report Yourtown, US 12345 Page 1 of 24 Table of Contents Invoice 2 Definitions 3 General Information 3 Lots and Grounds 4 Exterior 5 Roof 6 Garage/Carport

More information

www.citiesinspection.com October 5, 2015 Dear Client,

www.citiesinspection.com October 5, 2015 Dear Client, www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.

More information

COMPREHENSIVE PROPERTY INSPECTIONS

COMPREHENSIVE PROPERTY INSPECTIONS COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited

More information

Vari Inspection Services

Vari Inspection Services Cover Page Vari Inspection Services Property Inspection Report Inspection prepared for: Sample Real Estate Agent: None - Date of Inspection: 5/13/2015 Inspector: Tony Vari License # HI8047 23110 STRD 54

More information

Total Home Inspection Checklist

Total Home Inspection Checklist Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

Self-Home Inspection Checklist

Self-Home Inspection Checklist To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional

More information

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C. CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1234 School House Road Yourtown, US 12345 Prepared for: Bob Smith Prepared by: Your Company Name Here 9600 Colerain Ave Suite 110 Cincinnati, OH 45215 17:26 August 02, 2006 Page

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1234 School House Road Yourtown, US 12345 Prepared for: Bob Smith Prepared by: Your Company Name Here 9600 Colerain Ave Suite 110 Cincinnati, OH 45215 17:22 August 02, 2006 Page

More information

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES CHRIS CURLES and ASSOCIATES INSPECTION SERVICES Inc. Chris Curles, President www.homeinspectionsatlanta.com chriscurl@comcast.net Office: 770-493-0227 Professional Member Of: GAHI # 93006 ASHI # 211725

More information

General Home Inspection

General Home Inspection General Home Inspection Your New City, Ohio 12345 Prepared for: John and Jane Homebuyer Prepared by: General Home Inspection Page 1 of 18 Table of Contents Definitions 2 General Information 2 Lots and

More information

South Carolina Home Inspector Standards of Practice

South Carolina Home Inspector Standards of Practice South Carolina Home Inspector Standards of Practice The following Standards provide guidelines for the Residential Home Inspector and outline what the Residential Home Inspector should observe, identify,

More information

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668 Inspection Report Property Address: 123 Dream Home Way Frisco, CO 80443 Prepared for: Inspector: Tim Nixon Tim Nixon Inspection date: 3/28/2014 1 of 9 General Information Property Information Address:

More information

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE

More information

Orlando Home Inspection Services

Orlando Home Inspection Services PLEASE NOTE: Orlando Home Inspection Services Serving Central Florida since 1999 P O Box 915451, Longwood, Florida, 32791-5451 Phone: (321) 228-2493 Fax: (407) 374-8505 Web: http://www.orlando-home-inspections.com

More information

Building Condition Assessment Report

Building Condition Assessment Report C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses

More information

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide A comfortable house is a great source of happiness. - Sydney Smith Home Maintenance Guide HOME GUIDE By conducting regular maintenance checks, you can prevent small inexpensive repairs from becoming more

More information

Building Condition Assessment Report

Building Condition Assessment Report Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.

More information

Strickland Home Inspections, LLC 10200 38th Ct N Plymouth, MN 55441. Inspection Report. xxxx St Clair Ave St Paul, MN 55105

Strickland Home Inspections, LLC 10200 38th Ct N Plymouth, MN 55441. Inspection Report. xxxx St Clair Ave St Paul, MN 55105 10200 38th Ct N Plymouth, MN 55441 Inspection Report xxxx St Clair Ave St Paul, MN 55105 Page 1 of 27 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior Surface and Components

More information

Peak Home Inspection Services

Peak Home Inspection Services 09:48 July 28, 2009 Page 1 of 13 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection A Acceptable Functional with no

More information

19 Ellis Park Road, Toronto

19 Ellis Park Road, Toronto 19 Ellis Park Road, Toronto Inspection Report September 9, 2015 19 Ellis Park Road, Toronto Inspection Report Overall Condition: This is a solidly built older double-brick home that is in fairly original

More information

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist

More information

159 Morningside Avenue, Toronto

159 Morningside Avenue, Toronto 159 Morningside Avenue, Toronto Inspection Report February 6, 2013 159 Morningside Avenue, Toronto Inspection Report Overall Condition: This 60±-year-old home was extensively renovated and extended in

More information

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Inspection Report Atlanta Strip Mall Commercial Building Property Address: Page 1 of 25 Inspection Report Atlanta Strip Mall Property Address: Smyrna GA 30082 Page 2 of 25 South East Building Consultants Ray Thoroman Serving the entire State of Georgia 6 678-410-3005 Page 3 of

More information

Propery Inspection Report

Propery Inspection Report Propery Inspection Report Cover Page,, Ok Inspection prepared for: Date of Inspection: 9/28/2014 Time: 8:30 AM Age of Home: 2011 MOL Weather: Clear 62 degrees Inspector: License #130 5400 Hwy 177, Marland,

More information

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 PROPERTY DESCRIPTION PROPERTY INSPECTED: INSPECTION ADDRESS: 4722 Baltimore Avenue

More information

SWF Home Inspections

SWF Home Inspections Cover Page SWF Home Inspections Property Inspection Report Inspection prepared for: Mr & Mrs Home Buyer Real Estate Agent: My Favorite Agent - Date of Inspection: 7/4/2013 Age of Home: 2004 Size: 1568

More information

The Uniform Building Inspection Report Condensed

The Uniform Building Inspection Report Condensed The Uniform Building Inspection Report Condensed Single Family Residence:, Scottsdale, AZ Condensed Report Version Prepared for: John Doe Inspection Date: 9/19/2005, 1:00:00 AM Report Number: 091805s Inspection

More information

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)355-1748

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)355-1748 Inspection Report provided by: Delaware Property Inspection Inspector: Richard Hiddemen (302)355-1748 ASHI # 243377 DPR #H4-0000018 DDA #06-444 Delaware 1992105842 Wilmington #03857 New Castle #2010-845

More information

GeorgiaHomePros.com. 6858 Yellow Creek Road Ball Ground, GA 30107 770-893-2271 www.georgiahomepros.com inspections@tds.net Inspected By: Scott Webb

GeorgiaHomePros.com. 6858 Yellow Creek Road Ball Ground, GA 30107 770-893-2271 www.georgiahomepros.com inspections@tds.net Inspected By: Scott Webb GeorgiaHomePros.com 6858 Yellow Creek Road Ball Ground, GA 30107 770-893-2271 www.georgiahomepros.com inspections@tds.net Inspected By: Scott Webb Home Inspection Report Prepared For: Jack & Diane Samples

More information

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas 5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 harris31@sbcglobal.net INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction

More information

RRIO Checklist. Use of checklist: Definitions: Limitations

RRIO Checklist. Use of checklist: Definitions: Limitations CITY OF SEATTLE RENTAL REGISTRATION AND INSPECTION ORDINANCE (RRIO) RRIO Checklist Use of checklist: Property owners will use the RRIO Checklist to confirm that their rental housing properties and units

More information

Inspection Item COMMENTS

Inspection Item COMMENTS APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:

More information

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288 Page 1 of 22 Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288 Printed Friday, January 16, 2015 Inspected By: Dale Gibbs Referral Information Joe Agent Client Information:

More information

2. What building projects are exempted? (permit not required)

2. What building projects are exempted? (permit not required) BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and

More information

License Requirements for Persons Engaging in the Business of Inspection Practice:

License Requirements for Persons Engaging in the Business of Inspection Practice: SC Standards of Practice SOUTH CAROLINA RESIDENTIAL BUILDERS COMMISSION HOME INSPECTOR STANDARDS OF PRACTICE Adopted by the Residential Builders Commission May 13, 1998 PURPOSE: The purpose of a residential

More information

Pre-Drywall Inspection Report

Pre-Drywall Inspection Report SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792

More information

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois Accurate Home Inspection of Illinois 815-260-1727 1213 Norley st. Joliet, illinois 60435 aaccurate1@yahoo.com We Inspect to Protect!!! Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave.,

More information

A and S Property Inspector

A and S Property Inspector Cover Page A and S Property Inspector Property Inspection Report Inspection prepared for: xxxxx xxxxx Real Estate Agent:.. - Date of Inspection: 8/25/2014 Time: 10am Age of Home: 1999 Size: 1841 Weather:

More information

PROPERTY INSPECTION REPORT Property Address:

PROPERTY INSPECTION REPORT Property Address: Scott Certified Member P. O. Box 9007 Indianapolis, IN 690-007 (7)-750-60 Fax: 7-876-8 PROPERTY INSPECTION REPORT Property Address: Prepared for: Inspection Inspector: Lou Buehler Inspection #: BUYERS

More information

November 18, 2010. Customer Name Customer Address. Inspection Address Seattle, WA Inspection #: Dear Customer:

November 18, 2010. Customer Name Customer Address. Inspection Address Seattle, WA Inspection #: Dear Customer: 5921 Indian Trail SE Tacoma, WA 98422 253-235-5678 Fax: -- www.homteaminspection.com/southsound E-mail: ht646@hometeaminspection.com November 18, 2010 Customer Name Customer Address RE: Inspection Address

More information

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN 12345. 1234 USA Drive. Morris Home Inspection Group, LLC

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN 12345. 1234 USA Drive. Morris Home Inspection Group, LLC Inspection Report Mr. Sample Sample Property Address: 1234 USA Drive Indianapolis IN 12345 1234 USA Drive Morris Home Inspection Group, LLC Cedric Morris HI01200039 Fishers, IN 46037 317-550-6281 Table

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 555 Wind Way, Fake City, OR 54645 Inspection Date: Monday May 12, 2014 Prepared For: John Doe Prepared By: House to Home 3468 N. Bartlett Ave Milwaukee, WI 53211 262-754-5973 christopher@ahit.com

More information

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396 BUILDING ANALYSIS REPORT July 25, 2014 John Doe 1234 Smith Road Atlanta, Georgia 30396 Agent: Ausker and Barbara Morris AT Morris Realty Group, Inc. 3162 Johnson Ferry Road, Suite 260-25 Marietta, Georgia

More information

I NI NP R Inspected Items

I NI NP R Inspected Items 6/ /07 The Inspection of the property listed above must be performed in compliance with the rules of TREC. The inspection is of conditions which are present and visible at the time of the inspection, and

More information

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live! U.S. Department of Housing and Urban Development Office of Public and Indian Housing A Good Place to Live! Introduction Having a good place to live is important. Through your Public Housing Agency (or

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

SNS Home Inspections LLC

SNS Home Inspections LLC Cover Page SNS Home Inspections LLC Property Inspection Report 12345 Inspection prepared for: Donald Duck Real Estate Agent: - Date of Inspection: 2/21/2015 Time: 1:00 PM Age of Home: 1988 Size: 1866 sq

More information

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check #1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check Zoning laws Deed restrictions on home size, foundation style, roof pitch, etc. Suitability (slope, wetland issues, etc.) Accessibility

More information

Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066

Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066 Page 1 of 58 Inspection Report Prepared For: Atlanta Commercial Customer Property Address: Building 5 Marietta, GA 30066 Superior Home Inspections Ray Thoroman 8070 Ivy Shaw Dr. Gainesville,GA 30506 678-410-3005

More information

Inspecting to a higher standard.

Inspecting to a higher standard. Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com

More information

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: 61-30.801 Standards of Practice, General. (1) Home inspections performed to these Standards of Practice are intended to provide the client with information

More information

Rehab Inspection Report Page 1

Rehab Inspection Report Page 1 Rehab Inspection Report Page 1 Home Address: Construction Style: Number of bedrooms Square footage: Value of offer: Estimated rehab cost: Value of resale: Orientation of house: N S E W Note: orientation

More information

Open House and Home Tour Checklist

Open House and Home Tour Checklist 1 The House Address: Number of floors: Listing price: Basement? Property tax: Outdoor space? Eugh closet space? Style: Eugh storage space? Square footage: Room for expansion? Number of bedrooms: What appliances

More information

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick Prepared by: The Inspection Guys www.inspectionguys.com 16 Mt. Bethel Road, Suite 171 Warren, NJ 07059 800-903-0670 Fax: 732-238-7092

More information

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS Insurance Inspection Report 1234 Main Street Tallahassee, Florida Report Prepared For: Charles Smith Report Prepared

More information

South Carolina Home Inspector Standards of Practice

South Carolina Home Inspector Standards of Practice South Carolina Home Inspector Standards of Practice The following Standards provide guidelines for the Residential Home Inspector and outline what the Residential Home Inspector should observe, identify,

More information

Inspection Report. Property Address: St. Marks Ave. Brooklyn NY 11213. Five Borough Home Inspection, LLC. Derek Lomer

Inspection Report. Property Address: St. Marks Ave. Brooklyn NY 11213. Five Borough Home Inspection, LLC. Derek Lomer Inspection Report Property Address: St. Marks Ave. Brooklyn NY 11213 Five Borough Home Inspection, LLC Derek Lomer NYS Licence Lic # 16000051234 790 Washington Ave., Unit 112 Brooklyn, NY, 11238 917-494-8474

More information

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM Pa g e 1 o f 1 5 All About Homes, LLC Michelle M. Teague Owner 312-371-7414 Phone 773-508-6209 Fax www.michelleinspects.com michelle@michelleinspects.com 1725 W. Granville Ave. Chicago, IL 60660 Printed

More information

Inspection Report. "Even small homes, could have big problems"

Inspection Report. Even small homes, could have big problems Inspection Report "Even small homes, could have big problems" This inspection report prepared specifically for: Happy Buyer Inspect Before You Buy, Order Today. 209.834.5447, CA 88888 Inspected by: Randy

More information

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space) COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.

More information

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm Burns Home Services Service Makes the Difference 2620 W Grovers Ave, Phoenix, AZ 85053 Tel: 602-889-6970 Fax: 602-870-4563 Mobile: 602-291-7138 Garryh@burnshomeservices.com SUMMARY REPORT Client: John

More information

G.Warren, Inc. Home Inspection

G.Warren, Inc. Home Inspection 13:22 January 29, 2014 Page 1 of 37 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection Appears Serviceable We did

More information

INSPECTION REPORT. LOCATION OF PROPERTY 1234 Sample Street Tucson, AZ 85701. CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008

INSPECTION REPORT. LOCATION OF PROPERTY 1234 Sample Street Tucson, AZ 85701. CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008 INSPECTION REPORT LOCATION OF PROPERTY 1234 Sample Street CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008 INSPECTOR Dave Woityra FILE CODE: 0100114.SAM AGENT Sample Q. Jones A.B.C.

More information

Home. Safe. Home. home inspection report

Home. Safe. Home. home inspection report home inspection report Home. Safe. Home. Each office is independently owned and operated. 2013 The HomeTeam Inspection Service, Inc. All rights reserved. What is a home inspection? The purpose of a home

More information

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX SUMMARY REPORT Report Number: 1860 Inspection Date: Saturday, February XX, XXXX Property Address: XX XXXXX XXX Toronto, ON XXX XZX Client Name: Xxxx Xxxxxxxxxxxxx Prepared by: Andrew Marioselva BSc,CHI

More information

HEDDERMAN ENGINEERING, INC. 3011 Carrie Cove Ct., Spring, TX 77386 281-355-9911, fax 281-355-9903 Tim@heddermanengineering.com

HEDDERMAN ENGINEERING, INC. 3011 Carrie Cove Ct., Spring, TX 77386 281-355-9911, fax 281-355-9903 Tim@heddermanengineering.com HEDDERMAN ENGINEERING, INC. 3011 Carrie Cove Ct., Spring, TX 77386 281-355-9911, fax 281-355-9903 Tim@heddermanengineering.com 2007 TO: Mr. REF: CONDITION OF PROPERTY SURVEY Dear Mr. : At your request,

More information

CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO 44120 (216) 491-1470 POINT OF SALE CERTIFICATE OF INSPECTION

CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO 44120 (216) 491-1470 POINT OF SALE CERTIFICATE OF INSPECTION CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO 44120 (216) 491-1470 POINT OF SALE CERTIFICATE OF INSPECTION Notice Issued: November 10, 2011 File: 2011-0441 To:

More information

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division Code Enforcement Inspection Manual City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division LIVING ROOM 304.15 EXTERIOR DOOR(S) Check door(s) and trim for condition,

More information

ink Home Inspections, LLC

ink Home Inspections, LLC Cover Page ink Home Inspections, LLC Property Inspection Report 98156 Inspection prepared for: Carey Smith Real Estate Agent: agent 007 - ACME Homes Date of Inspection: 9/14/2013 Time: 9:00am - 12:00pm

More information

The BrickKicker is pleased to present this professional home inspection report for the property located at: 123 Main St. Happy Town, IL 65432

The BrickKicker is pleased to present this professional home inspection report for the property located at: 123 Main St. Happy Town, IL 65432 The BrickKicker is pleased to present this professional home inspection report for the property located at: 123 Main St. Happy Town, IL 65432 inspected on 05/26/2014 For more information please contact

More information

CONDITION OF QUALITY ITEMS

CONDITION OF QUALITY ITEMS CONDITION OF QUALITY ITEMS FOUNDATION Always look for moisture problems and any bulges or irregularities in the walls. Lines on the walls or floors may indicate water problems. Have these been cured? If

More information

How To Check For A Deficiency

How To Check For A Deficiency UPCS in Pictures The following pictures are not all inclusive nor does it cover every deficiency. The pictures, however are some of the most commonly cited deficiencies on REAC inspections. Erosion The

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: Somewhere, FL CLIENT: GAIA GC ID No: 2015000 DATE: 12/31/2015 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792 FLORIDA

More information

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010 Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010 Tel: (804) 378-0861 terry@prospectpropertiesva.com Inspection

More information

INVOICE. DATE: May 11, 2005. DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

INVOICE. DATE: May 11, 2005. DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl. INVOICE DATE: May 11, 2005 CLIENT: The Buyer DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl. TOTAL FEE: $ See Schedule Tom Villani Hallmark Inspection

More information

City of St. Charles Basement Finish or Remodel

City of St. Charles Basement Finish or Remodel City of St. Charles Basement Finish or Remodel Building & Code Enforcement Division 2 East Main Street St. Charles IL 60174 630.377.4406 (Office) 630.443.4638 (Fax) http://www.stcharlesil.gov Please direct

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1303 Eagle Flight Lane Fort Collins, CO 80528 Prepared for: Cury & Molly Buyer Prepared by: KBar Assessments, Inc. 1827 East Harmony Road Fort Collins, CO 80528 10:08 July 12, 2014

More information

OC Home Inspect. 333 S Crest Rd Orange, CA 92868 (714) 478-3324 www.ochomeinspect.com guybrianadams@gmail.com Inspected By: Brian Adams

OC Home Inspect. 333 S Crest Rd Orange, CA 92868 (714) 478-3324 www.ochomeinspect.com guybrianadams@gmail.com Inspected By: Brian Adams OC Home Inspect 333 S Crest Rd Orange, CA 92868 (714) 478-3324 www.ochomeinspect.com guybrianadams@gmail.com Inspected By: Brian Adams Comprehensive Property Inspection Prepared For: Property Address:

More information

Housing Quality Standards Inspection Checklist

Housing Quality Standards Inspection Checklist Housing Quality Standards Inspection Checklist To prevent delays, the R.T.A. must be complete and upon submission the unit must be in move in condition or an inspection will not be conducted. A Fair Housing

More information

Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections

Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections Page 1 of 37 Inspection Report Prepared For: Sampath Sample Property Address: Alpharetta, GA 30004 Atlanta Home Inspections Matthew A Thoroman 6625 Hwy. 53 E. Ste. 410-151 Dawsonville Ga 30534 (678)-410-8062

More information

Home Warranty Inspection Report

Home Warranty Inspection Report Scope of the Inspection 1111 Sample Dr. home warranty inspection 2/30/2006 Home Warranty Inspection Report 1111 Sample Dr., Detroit, MI 48223 Inspection Date: February 30, 2006 Client: Alfred E. Neumann

More information

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through

More information

Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire.

Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire. Attached Garage Garage-house door isn't auto-closing. Recommend installing hinges with springs or an automatic door closing device so door closes automatically to prevent vehicle fumes from entering building.

More information