Gear Type Flow Meter VC
|
|
- Harry Anthony
- 8 years ago
- Views:
Transcription
1 Gear Type Flow eter VC
2 Construction and Function Construction 1 Housing Cover 3 Gear reamplifier 5 Connector Sensor 7 Bearing assembly Function The measuring gears are driven by the liquid flow on the principle of a gear motor. The gears run without contact in the measuring chamber. The bearing elements are low-friction ball or plain bearings. The movement of the gears is sampled without contact by means of two sensors located in the cover. Between sensor compartment and measuring chamber is located a pressure-resistant, non-magnetic separator plate. When the measuring mechanism rotates by one tooth pitch, the sensor emits a signal which corresponds to the geometrical tooth volume V gz. The signal is converted into a square-wave signal by the preamplifier. The two-channel sampling permits better resolution as well as recognition of the flow direction. RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 3
3 roduct Characteristics Optimized for individual applications because the series have been rendered media-specific by means of differing clearances, bearing variants and materials. Wide measuring ranges with sizes graduated to meet specific requirements. easurement independent of viscosity within the specified ranges. ow pressure drop High-response measurement High working pressure ow noise emission High-precision measurement with outstanding reproducibility Temperature-independent output signals over a wide temperature range High degree of accuracy, even with low flow rates at the bottom end of the measuring range High working reliability of the electronics Easy to use terminal of the preamplifier Working indication of the electronic Sensor system and preamplifier in EC-compatible design Explosion-proof version available for all volume counters Typical Applications Application edium Version Series Flow rate measurement oil, brake fluid, skydrol, diesel Spheroidal cast iron (hydraulic test stand) lubricating ball bearings low viscosity minimal clearances 1 Oil metering gear oil Spheroidal cast iron (metering plant) lubricating ball bearings medium viscosity increased clearances Consumption measurement offset ink Spheroidal cast iron (rinting press) lubricating bronze plain bearings high viscosity large clearances 3 Ratio control polyol + isocyanate, adhesives, resin, silicon Spheroidal cast iron ( component plant) low lubricity carbide plain bearings medium viscosity increased clearances Batching control clear lacquer, cavity waxes stainless steel (lacquering plant) low lubricity carbide plain bearings medium viscosity increased clearances 5 Flow rate measurement solvent stainless steel (lacquering plant) lubricating ball bearings low viscosity minimal clearances For fluids with a low viscosity and poor lubricity a hybrid ball bearing (with ceramic balls) is a available for sizes VC.5, VC., VC. and VC 1. Flow meters with hydrid ball bearing are available in Spheroidal cast iron (series 7) and stainless steel (series ). RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
4 Accuracy Characteristics The accuracy figures quoted by RACHT refer to the geometric tooth volume V gz, that is to say the percentage deviation applies to the current value in each case. The linearity error over the entire measuring range is < ±.1 % Reproducibility of a measured value is <.1 % Accuracy checking forms part of quality inspection in every case. On request the result of the test will be documented in the form of an accuracy characteristic curve; an example relating to a series 1 VC 1 is given below. The accuracy values quoted by racht are confirmed by the DD (German Calibration Service). Accuracy 1.5 cm Volume per pulse % V gz = % inearity 1.5 cm Volume per pulse % V gz = % RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 5
5 General Characteristics Design Connection type ounting position Flow direction Viscosity ax. pressure drop gear motor plate mounting/pipe connection optional optional mm /s, (according to series) Δp max = 1 Working Characteristics Nominal geom. max. working pressure eak pressure Sound pressure Resolution size toothvolume Standard- High pressure Standard- High pressure level version version version version (/79) (/79) V gz p max p max p^ p^ A Imp/l cm 3 db (A).5.5 <... < <...5 < < < < < < <.5 RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
6 ermitted Temperature Ranges Sealing materials Series F ED FE FF Ambient temperature --15 C + C --3 C + C --3 C + C --15 C + C edium temperature 1,,, 7, --15 C + 1 C --3 C + 1 C --3 C + 1 C --15 C + 1 C for standard version 3,, C + C --3 C + C --3 C + C --15 C + C edium temperature 1,,, 7, --15 C + 15 C --3 C + 13 C --3 C + 15 C --15 C + 15 C for high temperature version 3,, 5 on request on request on request on request for high temperature US version 1,,, 7, --15 C + 15 C --3 C + C* --15 C + C* edium temperatur 1,,,7, --15 C + C --3 C + C --3 C + C --15 C + C for -version 3,, C + C --3 C + C --3 C + C --15 C + C for -version high temperature US * for sizes VC.5...VC.1 max. 1 C 1,,, 7, --3 C + C Series Selection / Summary of Variants Series aterial housing Spheroidal Spheroidal Spheroidal Spheroidal stainless stainless Spheroidal stainless cast iron cast iron cast iron cast iron steel steel cast iron steel EN-GJS--15 EN-GJS--15 EN-GJS--15 EN-GJS EN-GJS (/79 EN-GJS--3) aterial gears steel steel steel steel stainless steel stainless steel steel stainless steel Bearing ball bearings ball bearings bronze- carbide carbide stainless steel hybrid hybrid plain bearings plain bearings plain bearings ball bearings plain bearings ball bearigs Connection /R /R /R ax. perm. foreign particle size in the medium (μm) Accuracy ±.3 % ±.5 % ± 1 % ±.5 % ±.5 % ±.3 % ± 1 % ± 1 % (from measuring value) at mm /s at 5 mm /s at mm /s at mm /s at mm /s at mm /s at mm /s at mm /s Nominal Starting size point at easuring range [] [] * , * easuring accuracy ± 3 %; inearity ± 1.5 % RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 7
7 Type ey Ordering example VC. F 1 S /.. means: Nominal size. / Seal F / Series 1 / late mounting / Electronic standard Special ID No. Connection type late mounting R ipe connection Series see series selection Electronics S standard (--3 C + 1 C) H high temperature (--3 C + 15 C) high temperature US (--3 C + C) V without preamplifier (for plug-in display SD1) X intrinsically safe (ATEX) (switching amplifier has to be ordered separately) X high temperature US ATEX (-- 3 C + C) (switching amplifier has to be ordered separately) roduct name Seal F F E ED FE FF Nominal size Special Versions Special ID Series Description 55 1 version with aluminium connection box, preamplifier VV1 and Cannon plug 71 1 version with Hirschmann connector and round connector 1 x1 7 1 version with Hirschmann connector and preamplifier VV1 for 1 Volt power supply (.5 1 Volt) 79 1 VC 3 and VC 5 in high pressure version ( ) VC 3 and VC 5 in high pressure version ( ) Skydrol resistant, and aluminium connection box with Cannon plug Skydrol resistant, and aluminium connection box with Cannon plug. RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
8 Electrical Connection Standard version / High temperature version Volt (brown) Signal output channel Channel 1 (green) High temperature US version Electrical connection (Round connector 1 x 1/-pin) () Channel 1 (black) (1) V (brown) Signal output channel Channel (yellow) (3) V (blue) () Channel (white) Volt (white) Electrical Characteristics Number of measuring channels Working voltage U op = VDC polarized ulse amplitude U A. U B ulse shape with symm. output signal Signal output square wave pulse duty factor/channel 1:1 ±15% N (NN on request) ulse offset between two channels 9 ± 3 ower requirement b max =.9 W Output power/channel a max =.3 W short-circuit-proof Degree of protection I 5 DIN 5 Signal Characteristics Channel I B A rising edge C F B one pulse (corr. to flow rate of geom. tooth volume V gz) D C falling edge D ON phase E OFF phase F pulse duty factor 1:1 ± 15 % A I E ±15 U A Channel II G channel offset H flow direction 1 reversal of flow direction J flow direction G II 9 ±3 H J U A RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 9
9 Explosion-roof Design (ATEX) Function All volume counters are available in explosion-proof design according to ATEX. The explosion-proof design consists of the volume counter (intrinsically safe electrical apparatus) and the switching amplifier 13 (associated electrical apparatus). The type of protection intrinsic safety applies to this construction. The volume counter is installed in the potentially explosive atmosphere. The mounting of the amplifier 13 is carried out in the safe area. Volume counter and switching amplifier are electrically connected to each other. The switching am plifier evaluates the sensor signals and converts them to square-wave signals. Without switching amplifier, the volume counter must not be operated in the potentially explosive atmosphere. Cable lengths of up to m are possible between volume counter and switching amplifier. ED s for monitoring line breaks / short circuits, channel switching state and power supply are located on the switching amplifier. Safe area otentially explosive atmosphere brown white Channel 1 Channel 13 shield brown white VC Volt Volt 7, and 9 jumpered green yellow A green yellow II () G [EEx ia] IIC TB 3 ATEX 9 X II GD EEx ia IICT TB 3 ATEX 9 Note: This graph is an example only. National laws for potentially explosive areas must be considered. Technical Data of Switching Amplifier -13/3-E- ower supply Supply voltage cl. 7 (+), cl. (--) DC Volt ± % Ripple content white Wss < % Outputs (non-intrinsically safe) Characteristics cl. 9, 1,, 11 Electronics outputs Short-circuit current Signal level 1-signal Signal level -signal Ambience conditions inimum limiting temperature aximum limiting temperature electrically isolated via optoelectronic coupler approx. 5 ma. x supply voltage with R > k ohm inhibited output, residual current < ua ( - 5 C) 333 (+ C) echanics Dimensions 7.5 x 9 x mm Connection possibility can be snapped on a 35 mm mounting channel DIN 77 Weight approx. 15 g RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
10 ressure Drop Series 1,,, 7 and arameter: Viscosity (mm /s) VC VC VC.5 (extract) VC. (extract) VC VC. RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 11
11 ressure Drop Series 1,,, 7 and arameter: Viscosity (mm /s) VC VC VC VC VC VC RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
12 ressure Drop Serie 3 arameter: Viscosity (mm /s) VC VC 5 RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 13
13 ressure Drop Series /5 arameter: Viscosity (mm /s) VC VC VC. 3 5 VC VC VC 5 RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
14 Dimensions Series 1,, 3,, 7 Connection type Nominal Available Weight Tightening Dimensions size series torque kg Nm mm m A A C D F GS GH J N VC.5 1, VC. 1, VC VC. 1,,, VC. 1, VC 1 1,, 3,, VC 3 1,, VC 5 1,, 3, J 3 F G S G H O-Ring C N Version S and Version X Tightening torque A Version H Connection dimensions D A N RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 15
15 Dimensions Series 1 High pressure version (/79) Nominal Weight Tightening Dimensions size torque kg Nm mm Series 1 Standard version m A C D F GS GH J N VC VC Nominal Weight Tightening Dimensions size torque kg Nm mm m A C D F GS GH J N VC VC J 3 C G H N F G S N ø D 1 RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
16 Dimensions Connection plate (Spheroidal cast iron) for VC 3/79 and VC 5/79 (high pressure) with side SAE flange connection Ordering Weight Dimensions code kg mm m A B C E F G N R a b e f VC 5 V1 E9* /15 t / t / t * fits for VC 3 and VC 5 Connection plate for VC 1 and VC 1 with side SAE flange connection Ordering Weight Dimensions code kg mm m A B C E F G N R a b e f VC 1 V1 G9** / t /5 t /5 t ** fits for VC 1 and VC 1 ø A E f G C b B F R e a ø A X X N RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 17
17 Dimensions Series 5, and (stainless steel) Connection type Nominal Available Weight Tightening Dimensions size series torque kg Nm mm m A C D F GS GH J N VC.5 5,, VC., VC.1, VC. 5,, VC , VC 1 5,, VC 3 5, VC 5 5, J G S G H F O-Ring Ø D C Ø N Version S and Version X Tightening torque A Version H Connection dimensions Ø N 1 RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
18 Dimensions Series 5, and (stainless steel) Connection type R Nominal Available Weight Dimensions size series kg mm m A B C D E F GS GH H J VC.5 5,, 3. G VC., 3. G VC.1, 3. G VC. 5,, 3.1 G VC. 5. G VC 1 5,, 7 G VC 3 5, 15.9 G VC 5 5, 1.7 G J Ø C A E B H F G S G H Ø Ø D Version S and Version X Version H RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 19
19 Dimensions VC High Temperature US Nominal Weight Tightening Dimensions size torque kg Nm mm m A A C D F G J N VC VC VC VC VC VC VC VC D High temperature US area Normal area 5 engths ordering designations 5 J 1, Tightenning torque 3 F G 3 O-Ring C A View X Ø,3 Connection dimensions N RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
20 Dimensions VC High Temperature US Nominal Weight Tightening Dimensions size torque kg Nm mm m A C D F G J N VC 3 / VC 5 / VC VC High temperature US area 5 engths ordering designations J Normal area 5 1, Tightenning torque 3 Ø,3 N 3 F C G Connection dimensions View X ø D N RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 1
21 Connection plates (cast iron) with side threaded connection Ordering Weight Dimensions code kg mm m A B C E F G H J N R c d e f VC. R 3 B 5* /t G 3 13 VC. R 3 C 5* /t G 1 15 VC. R 1 C / 1 t G 1 15 VC. R 1 D /1t G 3 17 VC 1 R C / 1 t G 1 15 VC 1 R 3 D /1t G 3 17 VC 1 R E / 1 t G1 19 VC 5 R E 5** /t 1 G1 19 VC 5 R G 9** /t 1 5 G1 1 3 ** fits for VC.5, VC., VC.1 and VC. ** fits for VC 3 and VC 5 A E øh B F R C J øg View X f D R C N e d c øg X Ansicht X Connection plates (cast iron) with side SAE flange connection Ordering Weight Dimensions code kg mm m A B C E F G H J N R a b e f VC 5VE 5** / t / t VC 5V1F / t / 5 t ** fits for VC 3 and VC 5 A E øh f C b B F J R N øg e a View Ansicht X x RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
22 Connection plates (cast iron) with rear threaded connection Ordering Weight Dimensions code kg mm m A B C E F G H J N R c d e f VC. R 3 B * /t.7 5 G 3 13 VC. R 1 C / 1 t.7 9 G 1 15 VC. R 1 D / 1 t G 3 17 VC 1 R C / 1 t G 1 15 VC 5 R E ** / t 55 1 G 1 19 ** fits for VC.5, VC., VC.1 and VC. ** fits for VC 3 and VC 5 A C E J G N B øg c f d øh e R F Connection plates (cast iron) with rear SAE flange connection Ordering Weight Dimensions code kg mm m A B C E F G H J N R a b e f VC 5 V E ** / t / t ** fits for VC 3 and VC 5 A C E J f b B R F øh øg N e a RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 3
23 Connection plates (Stainless steel) with side threaded connection Ordering Gewicht Dimensions code kg mm m B D C E G H J N R e f VC. R B11* / t 1 G 3 13 VC 1 R3 C /1 t 19.5 G 1 15 VC 1 R D /1 t 1 G 3 17 VC 5 R E11** / t 5 G1 19 VC 5 R G11** / t 3 G1 1 3 ** fits for VC.5, VC., VC.1 and VC. ** fits for VC 3 and VC 5 ø D E C J ø H B ø G e f N R RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
24 Note RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 5
25 Note RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web
26 Note RACHT GmbH Gewerbestr Werdohl, Germany fon +9()3 9/935- fax +9()3 9/935 9 mail info@kracht.eu web 7
27 roduct ortfolio Transfer umps Transfer pumps for lubricating oil supply equipment, low pressure filling and feed systems, dosing and mixing systems. obile Hydraulics Single and multistage high pressure gear pumps, hydraulic motors and valves for construction machinery, vehicle-mounted machines. Flow easurement Gear and turbine flow meters and electronics for volume and flow metering techno logy in hydraulics, processing and laquering technology. Industrial Hydraulics / Test Bench Construction Cetop directional control and proportional valves, hydraulic cylinders, pressure, quantity and stop valves for pipe and slab construction, hydraulic accessories for industrial hydraulics (mobile and stationary use). Technology Test benches / Fluid Test benches. VC/GB/1.1 RACHT GmbH Gewerbestraße 5791 Werdohl, Germany fon +9 () 3 9 / 935- fax +9 () 3 9 / mail info@kracht.eu web
Gear Type Flow Meter VC
Gear Type Flow eter VC 2 RACHT COR. 86 S Wilkinson Way Unit A errysburg, OH 43551 USA +1 419 874 F +1 419 874 6 flowmeters@krachtcorp.com www.krachtcorp.com Construction and Function 3 4 5 6 2 1 7 Construction
More informationPressure Relief Valves SPV, SPVF
Pressure Relief Valves SPV, SPVF Construction of the Pressure Relief Valves SPV, SPVF Symbol Description The direct spring, sliding piston Pressure Relief Valve SPV/SPVF is intended for inline mounting
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationVP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
More informationTransfer Gear Pumps KF 4... 80
Transfer Gear Pumps K 4... Contents Technical data Dimension sheets Page Contents Page Contents.......................... 2 Applications........................ 2 Descriptions....................... 3
More informationTurbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationDifferential-Hall-Effect based Sensors Series A5S
Speed and Frequency Seite 1 von 6 Differential-Hall-Effect based Sensors Series A5S Outstanding Characteristics Speed range covering most demands: from close to zero up to 25,000 pulses/second (response
More informationSeries 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
More informationT1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V
Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity
More informationT1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V
Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity
More informationFluxi 2000/TZ Turbine Gas Meter
Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationRotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP
NORTH AMERICAN CYLINDER & ACTUATOR CATALOG > Release 8. Rotary Actuators and Grippers Rotary Actuators, NAMUR interface VDI/VDE 384 & ISO 211 (ATEX certified) Series ARP Model: Rack & Pinion - Rotational
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationSeries 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
More informationD.C. Motors. Products and specifications subject to change without notice.
D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationSEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationT U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
More informationElectric Lifting Cylinder TV / KV 5 XE Load up to 6.500 N
S+R S+R automation systems GmbH Electric Lifting Cylinder TV / KV 5 XE Load up to 6.500 N Lifting Moving Positioning Design and functuion An electric lifting cylinder is an electro-mechanical drive unit.
More informationDigital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationConductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
More informationEncoder WDG 58B. www.wachendorff-automation.com/wdg58b
Encoder WDG www.wachendorffautomation.com/wdgb Wachendorff utomation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and customer versions Maximum
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationHIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and
More informationFixed displacement vane pumps
Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double
More informationEncoder WDGI 58H. www.wachendorff-automation.com/wdgi58h
Encoder WDGI H www.wachendorffautomation.com/wdgih Wachendorff utomation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and customer versions
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More informationQR12 (1.22 ) Diameter Optical Encoder
Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions
More informationNon-contact Displacement Vibration TRANSDUCER
Shinkawa - Transdutores de Vibração Série VK VK series Non-contact Displacement Vibration TRANSDUCER A HIGH GRADE TRANSDUCER FOR SAFE- ROTATING MACHINERY OPERATION Complies with American Petroleum Institute
More informationConstruction of the Gear Pump KF
Transfer Gear Pumps Construction of the Gear Pump KF Plain Bearing Bush Driving Gear Flange Mounting Cover Outboard Bearing End Cover Drive Shaft End Shaft End Seal Housing Driven Shaft Pinion Product
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationSubminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationDSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationElectronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
More informationL-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
More informationFast, reliable, ultra-precise. My-Com precision switches.
Fast, reliable, ultra-precise.. Unrivaled 1 μm repeat accuracy Setting reference points, monitoring tolerances, controlling, adjusting. Fast, reliable, ultra-precise. Uncompromising accuracy tried and
More informationLENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space
PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
More informationRotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
More information15/40/80CN Series Medium Pressure Filters
1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationSpeed sensor MiniCoder GEL 247
Speed sensor MiniCoder GEL 47 Flange assembly Technical information version 08.0 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless measurement of rotational movements
More informationPlastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationRoHS. Shock / vibration resistant. Magnetic field proof. Many variants
Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.
More informationRickmeier Solutions. Gear pumps for superior Lubrication
Rickmeier Solutions Gear pumps for superior Lubrication P U M P E N T E C H N O L O G I E #1. Introduction Position and significance of Rickmeier products Rickmeier supplies pumps, valves and systems for
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationS300 Series Dust Monitors
S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust
More information2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
More informationIFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
More informationZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS 426 1.99 21.04
SIGMA UMY HRANICE GEAR UMS SIGMA UMY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz, 426 1.99 21.04 Application In
More informationDoc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationDimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationDXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30
85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More informationDescription. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
More informationTable of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors... 380
Proximity Switches Table of Contents, Magnetic Field Sensors Proximity Sensors.3 Magnetic Field Sensors.2.3 Introduction to Magnetic Field Sensors... 380 Operating Distance and Responsiveness Mounting
More informationT-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com
T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5 www.thomsonlinear.com Version History Edition Number Edition Date Reason for Revision 1 2004 First edition
More informationHG600/HG800. Hydro-Power Unit. Installation and Operation Guide
HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving
More informationSpeed Sensors Line Guide
Speed Sensors Line Guide Speed and reliability. Honeywell S&PS offers electronic speed designed for enhanced reliability and an extended life. Honeywell uses multiple technologies to detect a change in
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More information9000 Series Accelerometers Specifications
Technical Data 9000 Series Accelerometers Specifications Catalog Numbers EK-43781I, EK-43782I, EK-46255I, EK-45890I, EK-43784I, EK-47086I, EK-43792I, EK-47090I, EK-43799I, EK-43794I, EK-43795I, EK-43797I,
More informationMINEX -S. Magnetic coupling. You will find continuously updated data in our online catalogue at www.ktr.com
MINEX - 171 Table of contents NEW MINEX - 171 Coupling description 173 Technical description 174 s A 22/4 to B 60/8 with containment shroud made of stainless steel 175 s A 75/10 to F 250/38 with containment
More informationReaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
More informationBall valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value
Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationMaterial: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof
More informationLVDT. Inductive Position Transducer. SM Series. Key-Features:
LVDT Inductive Position Transducer SM Series Key-Features: Content: - Measurement ranges 2...200 mm - External, or cable electronics with cable break detection - Linearity up to ±0.10 % of full scale -
More informationThreaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationBM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
More informationE4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More information330505 Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing
More informationSITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents
English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force
More informationPneumatic actuators The Original! Technics of the top class.
Automatic valves Actuators Accessories Pneumatic actuators The Original! Technics of the top class. Leaflet no. S1-01e-13 Table of contents Advantages and your benefits...page 3 Figure: actuator...page
More informationGoTo Europe Focused Delivery Program. Product Overview Hydraulics
GoTo Europe Focused Delivery Program Product Overview Hydraulics 2 GoTo Europe The products I need when I need them In today s global competition every day counts. Fast response times have become an important
More informationRadial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationHLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B2325-1.0 en
HLC B1... HLC F1... HLC A1... HLC B1... HLC F1... Load cells Special features -- Hermetically sealed (IP68) -- Max. capacities: 220 kg... 10 t -- Stainless steel -- Low overall height -- Meets EMC/ESD
More information