1 Proximity Switches Table of Contents, Magnetic Field Sensors Proximity Sensors.3 Magnetic Field Sensors.2.3 Introduction to Magnetic Field Sensors Operating Distance and Responsiveness Mounting Conditions for Magnetic Field Sensors Magnetic "Penetrating Sensors" for Hydraulic Cylinders Type Code, Magnetic Field Sensors Data Section.3. Magnetic Field Sensors Accessories, Permanent Magnets Proximity Sensors Proximity Sensors, Capacitive Sensors Proximity Sensors, Magnetic Field Sensors USA: Germany: Singapore:
2 Proximity Sensors, Magnetic Field Sensors.3 Proximity Switches Introduction to Magnetic Field Sensors Unlike inductive or capacitive proximity switches, magnetic field sensors react to the presence of a magnetic field, regardless of whether this field is generated by an electromagnet or a permanent magnet. Compared with close-range sensors, they usually have longer operating distances Proximity Sensors, Magnetic Field Sensors, Sensors.3. Proximity Sensors, Magnetic Field Sensors, Accessories.3.2 Introduction to Magnetic Field Sensors Unipolar alignment of the magnet results in a central detection range with side curves. These side curves are responsible for maintaining a specific minimum distance between the magnet and the sensor to ensure safe switching behavior. Proximity Sensors, Capacitive Sensors, cylindrical Proximity Sensors, Capacitive Sensors, rectangular types Special technical characteristics of magnetic field sensors Long operating distance: longest operating distance compared to inductive and capacitive sensors based on housing size Variable operating distance: the required operating distance can be adjusted based on the magnet selected and installed Coding character: sensor reacts solely to magnetic fields Operating Distance and Responsiveness The possible sensing range of a magnetic field sensor depends on the size and magnetic flux density of the actuating magnet. A permanent magnet DM60 is used as a base for determining the rated sensing range (Sn). The magnet has a diameter of 3 mm and a height of 5 mm with a remanence B r of 380 to 00 mt. Mounting Conditions for Magnetic Field Sensors Due to the passive character of magnetic field sensors, unlike inductive or capacitive sensors, they can be flush mounted without affecting the operating distance. In contrast, the mounting conditions of the actuating magnet affect the operating distance. If the magnet is applied to a magnetizable carrier, the obtainable operating distance increases slightly. When the magnet passes laterally over the surface of the sensor, a polaritydependent response curve is produced. The response curve represents the sensing range of the sensor. The result is a bipolar alignment of the magnet: two symmetric curves. If the magnet is inserted flush into a magnetizable carrier material, the operating distance is considerably reduced by the magnetic "short circuit" through the carrier material. 380 USA: Germany: Singapore:
3 Proximity Switches Introduction to Magnetic Field Sensors Magnetic "Penetrating Sensors" for Hydraulic Cylinders The MB-F32 magnetic field sensor has a unique special feature. The sensor enables one of the pistons to be detected through the wall of a steel hydraulic cylinder. Once the piston passes under the sensor, the sensor generates a switching signal. This special function means that the sensor can be used to determine the position of the piston and also to count the piston strokes. Functional description of magnetic penetrating sensors The MB-F32 sensor reacts to low-level magnetic fields in the wall of the cylindermagnetic fields. It requires a magnetic field change in order to change its switching state. In the example below, the magnetic pole shoe of the piston induces a partial magnetic field in the steel cylinder wall. The sensor switches once the partial magnetic field passes under the sensor. Mounting magnetic penetrating sensors The MB-F32 magnetic field sensor is positioned on the outer surface of the steel cylinder wall and secured using a tightening strap. To create a functional system, a special pole shoe must be mounted to the piston inside the hydraulic cylinder. The shape and geometric dimensions of the pole shoe as well as the size and number of magnets depends on the configuration of the respective cylinder piston system. Consult the specialists at Pepperl+Fuchs.2 who can provide assistance with the requirements of the magnetic system design. Proximity Sensors Proximity Sensors, Capacitive Sensors.3 Proximity Sensors, Magnetic Field Sensors Cross section through a hydraulic cylinder with view of the cylinder and pole shoe Type code, magnetic field sensors M B 60-2 G M 50 - E2 - V Cylindrical usable threaded length (mm) Electrical Output A2 -wire, DC, PNP, antivalent E2 3-wire, DC, PNP, NO N, N NAMUR, NO M Metal G Threading Diameter in mm Rectangular type F32, F2 Operating range 35 mm or 60 mm Connection Elements V M2 x device connector for DC proximity switches V3 M8 device connector for DC proximity switchesgeeignet) J B C Initiator Basis line Comfort line M Magnetic USA: Germany: Singapore:
4 Proximity Sensors, Magnetic Field Sensors, Sensors Magnetic field sensor cylindrical, Ø 8 mm.3. Technical Data General Data Rated operating distance 60 mm Installation flush in non-magnetic metal Output type PNP NO Operating voltage V No-load supply current 0 ma Reverse polarity protection Switching frequency Hz Load current ma Short-circuit protection, self checking Switching state indication LED, yellow C ( F) Housing material Stainless steel.0 / AISI 36L Protection degree IP67 For detailed data and product description refer to the data sheets at Properties Ø8 mm housing Up to 60 mm sensing range (depends on magnet) DC, 3-wire switching output Cable and connector versions Benefits Small diameter, long sensing range Will work with north or south pole magnets Pos. A Pos. B III PELV Model Number Connection type Connector M8 x, 3-pin cable PUR, 2 m Approvals and Certificates Protection class III UL approval culus Listed, General Purpose CSA approval ccsaus Listed, General Purpose CCC approval CCC approval / marking not required for sensors rated 36 V Length L [mm] Diameter D [mm] M8 x Thread length l t [mm] 0 5 Cap length l [mm] 0 Connector length l c [mm] 0 6 LED position Accessories BF 8 DM V3-GM V3-WM V3-GM-BK2M-PUR-U V3-WM-BK2M-PUR-U These and more accessories can be found in chapter 0 See pages from for cordsets See pages for mounting accessories Mounting bracket, 8 mm Female connector, M8, 3-pin, field attachable, straight Female connector, M8, 3-pin, field attachable, angled Female cordset, M8, 3-pin, PUR cable, straight Female cordset, M8, 3-pin, PUR cable, angled MB60-8GM50-E2 MB60-8GM50-E2-V3 lc D l lt L Electrical Connection MB60-8GM50-E2 MB60-8GM50-E2-V3 BN BK BU 3 3 Wire colors in accordance with EN BN 3 BU BK (brown) (blue) (black) 382 USA: Germany: Singapore:
5 Magnetic field sensor cylindrical, Ø 2 mm Properties Ø2 mm housing Up to 60 mm sensing range (depends on magnet) DC, 3-wire switching output Cable and connector versions Benefits Long sensing range Will work with north or south pole magnets Pos. A Pos. B Technical Data General Data Rated operating distance 60 mm Installation flush in non-magnetic metal Output type PNP NO Operating voltage V No-load supply current 0 ma Reverse polarity protection Switching frequency Hz Load current ma Short-circuit protection, self checking Switching state indication LED, yellow C ( F) Housing material Stainless steel.0 / AISI 36L Protection degree IP67 Model Number For detailed data and product description refer to the data sheets at Connection type Connector M2 x, -pin cable PUR, 2 m Approvals and Certificates Protection class II UL approval culus Listed, General Purpose CSA approval ccsaus Listed, General Purpose CCC approval CCC approval / marking not required for sensors rated 36 V Length L [mm] Diameter D [mm] M2 x Thread length l t [mm] 29 0 Cap length l [mm] 0 Connector length l c [mm] 0 8 LED position Pos. B Accessories BF 2 DM V-G V-W V-G-BK2M-PUR-U V-W-BK2M-PUR-U These and more accessories can be found in chapter 0 See pages from for cordsets See pages for mounting accessories Mounting bracket, 2 mm -pin, M2 female field-attachable connector, straight -pin, M2 female field-attachable connector, angled Female cordset, M2, -pin, PUR cable, straight Female cordset, M2, -pin, PUR cable, angled MB60-2GM50-E2 MB60-2GM50-E2-V.3. Proximity Sensors, Magnetic Field Sensors, Sensors lc D l lt L Electrical Connection MB60-2GM50-E2 MB60-2GM50-E2-V BN BK BU Wire colors in accordance with EN BN 2 WH 3 BU BK (brown) (white) (blue) (black) USA: Germany: Singapore:
6 Proximity Sensors, Magnetic Field Sensors, Sensors Magnetic field sensor cylindrical, Ø 2 mm (NAMUR) Technical Data For detailed data and product description refer to the data sheets at General Data Rated operating distance Installation Output type Type of voltage Nominal voltage Current consumption Magnet detected Magnet not detected Switching frequency Switching state indication Housing material Protection degree 60 mm flush in non-magnetic metal NAMUR, NO DC 8.2 V (R i approx. k ) 2.5 ma ma Hz LED, yellow C ( F) Stainless steel.0 / AISI 36L IP Properties Ø2 mm housing Up to 60 mm sensing range (depends on magnet) NAMUR output Cable and connector versions Model Number Connection type Connector M2 x, -pin cable PVC, 2 m MC60-2GM50-N MC60-2GM50-N-V Benefits ATEX approved sensor applicable up to zone Intrinsically safe when connected to approved device FM Class/Div approvals Application Note: Reference appendix, data sheet, operating instructions, and appropriate standards. To be used within the electrical, environmental, and mechanical limitations of the device and area. Pos. A Pos. B Use in the Hazardous Area Use in the hazardous area see instruction manuals Category 2G Approvals and Certificates FM-control drawing 6-065F CCC approval CCC approval / marking not required for sensors rated 36 V Length L [mm] Diameter D [mm] M2 x Thread length l t [mm] 0 Cap length l [mm] 0 Connector length l c [mm] 0 8 LED position These and more accessories can be found in chapter 0 Accessories See pages from for cordsets See pages for mounting accessories BF 2 Mounting bracket, 2 mm DM V-G -pin, M2 female field-attachable connector, straight V-W -pin, M2 female field-attachable connector, angled V-G-N-2M-PUR Female cordset, M2, 2-pin, NAMUR, PUR cable, straight V-W-N-2M-PUR Female cordset, M2, 2-pin, NAMUR, PUR cable, angled KCD2-SR-Ex2 2-channel isolated amplifier For detailed information on isolated amplifiers refer to the data sheets at lc D l lt L Electrical Connection MC60-2GM50-N MC60-2GM50-N-V BN BU 2, 3, 2 3 Wire colors in accordance with EN BN 2 BU (brown) (blue) 38 USA: Germany: Singapore:
7 Magnetic field sensor F2 series, NAMUR Properties Miniature F2 housing Up to 35 mm sensing range (depends on magnet) NAMUR output Cable version Benefits 002 ATEX approved sensor applicable up to zone Intrinsically safe when connected to approved device FM Class/Div approvals Suitable for installation on aluminum pneumatic cylinder Application Note: Reference appendix, data sheet, operating instructions, and appropriate standards. To be used within the electrical, environmental, and mechanical limitations of the device and area. Technical Data Model Number Rated operating distance Installation Output type Type of voltage Nominal voltage Current consumption Magnet detected Magnet not detected Switching frequency Switching state indication Housing material Protection degree Connection type Use in the Hazardous Area Use in the hazardous area Category MJ35-F2-N For detailed data and product description refer to the data sheets at 35 mm flush NAMUR, NO DC 8.2 V (R i approx. k ) 3 ma ma Hz LED, yellow C ( F) anodized aluminum IP67 cable PVC, 2 m see instruction manuals 2G Approvals and Certificates FM-control drawing 6-065F CCC approval CCC approval / marking not required for sensors rated 36 V Length L [mm] 30 Width W [mm] 2 Height H [mm] 2 Connector length l c [mm] 0 These and more accessories can be found in chapter 0 Accessories See pages from for cordsets See pages for mounting accessories DM KCD2-SR-Ex2 2-channel isolated amplifier For detailed information on isolated amplifiers refer to the data sheets at Proximity Sensors, Magnetic Field Sensors, Sensors lc L H W Electrical Connection MJ35-F2-N BN BU USA: Germany: Singapore:
8 Proximity Sensors, Magnetic Field Sensors, Accessories Accessories for magnetic field sensors Model number.3.2 Ambient conditions Mechanical specifications Material C ( F) BaFe with steel jacket Height: 7 mm Diameter: 32 mm Model number DM Ambient conditions max. 200 C Mechanical specifications Material SrFe acc. to ratio 22/ Height: 5 mm Diameter: 3 mm Model number DM NDFEB DM 0-0 NDFEB DM 20-0 NDFEB s Ambient conditions max. 20 C (28 F) Mechanical specifications Material NdFeB acc. to ratio 262/35 Height: Diameter: Coating Ni + Sn (approx. 0-5 m) Note Packaging unit 20-piece DM mm 6 mm DM mm 0 mm DM mm 20 mm 386 USA: Germany: Singapore:
9 Sensors and Systems for Factory Automation Issue Proximity Sensors Proximity Sensors, Capacitive Sensors Proximity Sensors, Magnetic Field Sensors Proximity Sensors, Capacitive Sensors, cylindrical Proximity Sensors, Capacitive Sensors, rectangular types Proximity Sensors, Magnetic Field Sensors, Sensors Proximity Sensors, Magnetic Field Sensors, Accessories USA: Germany: Singapore:
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationMagnetic proximity switches
Magnetic proximity switches Magnetic proximity switches Overview Page 38 Functional principle and installation Page 39 Cylindrical designs Page 41 Rectangular designs Page 42 37 Kurzübersicht Magnetoresistive
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationTechnical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationTechnical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationMagnetic Proximity Switches Series CST - CSV and CSH
Magnetic Series CST - CSV and CSH Reed, Electronic»» Designed to fit into the cylinder profile barrel»» 3 models (CST - CSV - CSH) are suitable for all Camozzi s cylinder range»» With or without M8 connector
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationInductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
More informationDimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
More informationProximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30 Euronorm thermoplastic polyester housing, cylindrical Diameter: M 12, M 18, M 30. Sensing distance: 2 to 15 mm
More informationOPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric
More informationFloating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau
KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationsensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
More informationSENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
More informationProximity Switches RS (Reed Switch)
Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationTechnical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
More informationConductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationE2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL
High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationDSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
More informationInductive sensors. Compact, fast, reliable. Edition 2013
Inductive sensors. Compact, fast, reliable. Edition 2013 Indispensable in all machines Non-contacting, inductive proximity sensors play a major role in automation technology all over the world. For several
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationW 2: Subminiature photoelectric switch series: extremely small and extremely strong
Photoelectric proximity switches BGS Photoelectric proximity switches energetic, (V optics) Photoelectric reflex switches Through-beam photoelectric switches W : Subminiature photoelectric switch series:
More informationLED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
More informationRotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationOperating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
More informationNew XUY roller sensors
Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationHousing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
More informationCapacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
More informationRoHS. Shock / vibration resistant. Magnetic field proof. Many variants
Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationLED...A70..4-..Q Series Sealed High-Intensity
LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for
More informationFACTORY AUTOMATION LGS SERIES INTELLIGENT
FACTORY AUTOMATION LGS Series INTELLIGENT light Grid A LIGHT GRID WITH THE RIGHT TOUCH Lightning fast, adaptable, and cost-effective, the new LGS series light grids open the door to a wider range of detection
More informationCompact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
More informationDifferential-Hall-Effect based Sensors Series A5S Overview
A5S Differential-Hall-Effect based Sensors Series A5S Overall View KEY FEATURES Speed range from 0 Hz up to 25 khz (response time < 20 microseconds) Air gap to the target / pole wheel up to 2.5 mm (depending
More informationTubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationHow To Make An Ultrasonic Sensor
crm+ ultrasonic sensors Microsonic : TR Electronic: Tel: +49 231 975151-0 USA: 248-244-2280 Fax: +49 231 975151-51 Canada: 519-452-1233 www.microsonic.de www.trelectronic.com info@microsonic.de Description
More informationIsolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationIntroduction to Fiber Optic Cables. Photoelectric Sensors. 2Photoelectric Sensors, Standard Sensors, Fiber optic cables. Please Note!
Photoelectric, Standard, optic cables Photoelectric Introduction to Optic s Optic Diffuse and Thru-Beam Mode In applications involving small targets or unfavorable conditions, fiber optic cables may be
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
More informationOperating instructions Capacitive sensors
Operating instructions Capacitive sensors UK 700 / 00 0 / 009 Contents Safety instructions Functions and features Installation. Notes on flush and non-flush installation Electrical connection. Wiring.
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More information713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationCapacitive sensors. Versatile, contactless, durable Edition 2012/2013
Capacitive sensors Versatile, contactless, durable Edition 2012/2013 With capacitive sensors from Baumer you can complete almost any task. Invative all-rounders. Capacitive sensors can detect metallic,
More informationDifferential-Hall-Effect based Sensors Series A5S
Speed and Frequency Seite 1 von 6 Differential-Hall-Effect based Sensors Series A5S Outstanding Characteristics Speed range covering most demands: from close to zero up to 25,000 pulses/second (response
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationW150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More information14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
More informationSEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
More informationCAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
More informationLiquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
More informationMULTI-BEAM LS10 Light Screen System
For Sensing Small Parts at High Speeds Emitter and receiver pair produce a strobed array of modulated light beams to produce a light screen Simple, economical and highly reliable means of sensing small
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T
Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationLinear actuator Econom 0. Our intelligent model: Econom 0. Econom 0
Linear actuator Econom 0 Our intelligent model: Econom 0 Econom 0 Linear actuators Econom 0 Description Applications Facts The users of the steel or stainless steel Econom 0 come from many different industries:
More informationMaterial test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
More information96 Variants. The GlobalProx range increases in popularity. 12 PNP Normally-open 12 PNP Normally-closed 12 NPN Normally-open 12 NPN Normally-closed
BCS00K9 BCS00LK BCS00LL BCS00LM BCS00LN BCS00LP BCS00LR BCS00LT BCS00LU BCS00LW BCS00LY BCS00LZ BCS00M0 BCS00M1 BCS00M2 BCS00M3 BCS00M4 BCS00M5 BCS00M6 BCS00M7 BCS00M8 BCS00M9 BCS00MA BCS00MC BCS00ME BCS00MF
More informationW 260: Standard photoelectric switch series for a broad range of applications
W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of
More informationDirectory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationSensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
More informationSturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes
SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted
More informationDigital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationphotoelectric highlights www.automation.datalogic.com
photoelectric miniature sensors S8 series The new S8 series of compact sensors offers excellent detection performances, usually associated with sensors that have larger dimensions and a higher price. The
More informationtechnical data (according to IEC 60947-5-2)
Photoelectric sensors: Series 3#30 & 3#31 ü Complete miniature sensor series mm in rugged Crastin housings ü Shock & vibration resistant due to fully vacuum-potted electronics ü Diffuse sensors with precise
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-H
Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20
More information2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
More informationElectrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure
Electrical connection technologies Electrical connectors Electrical connectors with cable, series CN Brochure Electrical connection technologies Electrical connectors Electrical connectors with cable,
More informationInductive proximity sensors IM 12 series, sensing range 2 / 4 mm DC 3-wire, metal housing
Inductive proximity sensors IM series, sensing range / mm wire, metal housing Mx, 60 Dimensions in mm Mx 5 5 50 0, 60 Standard series Features Can be installed flush or nonflush in metal or output Normally
More informationGuide rail bracket (for adjustable heads)
(for adjustable heads) Part. 209 40 ø,5 ø10,5 2 2,5 115 15 42 5 11 37 72 4 70 Code 209 / 0754 MATERIALS: Bracket made out of reinforced polyamide black colour. FEATURES: To be used with heads Part.221,
More informationPlastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding